Loading...
HomeMy WebLinkAboutPermit D02-247 - REI - STORAGE RACKS• D02 -247 230 Andover Pk W I - - i . - y,X/ � , . 1 1 "14L11, pr i kikwila C it y o f r Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ' DEVELOPMENT PERMIT . i z , it Parcel No.: 0223100070 Permit Number: D02 -247 ~ W ' Address: 230 ANDOVER PK W TUKW Issue Date: 09/04/2002 CC QQ .g Suite No: Permit Expires On: 03/03/2003 U O . Tenant: u W Name: REI -J H Address: 230 ANDOVER PK W, TUKWILA, WA w LL w O Owner: 2 Name: LAKHA SOUTHCENTER PROP Phone: u_ Address: MANAGEMENT NORTHWEST, 120 W DAYTON ST #C -1 co d W Contact Person: I— Z.H Name: BILL LILE Phone: 425 467-6113 t--. O Address: 1257 EVERGREEN POINT ROAD, BELLEVUE, WA w } Li j Dp Contractor: U Name: DISPLAY TECHNOLOGY INTNL LLC Phone: 425 - 467 -6113 0 CO Address: 1257 EVERGREEN POINT ROAD, BELLEVUE WA Contractor License No: DISPLTI988NO Expiration Date: 08/20/2004 i U ' f - DESCRIPTION OF WORK: Z SUPPLY AND INSTALLATION OF METAL RACKING WITH PARTICLE BOARD SHELVES U N ~O '_ z Value of Construction: $0.00 Fees Collected: $534.56 . Type of Fire Protection: Uniform Building Code Edition: 1997 • Type of Construction: Occupancy per UBC: 0023 1 ' Public Works Activities: Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. ' Landscape Irrigation: N r Moving Oversize Load: N Start Time End Time: r' hf . Sanitary Side Sewer: N ' r ~n: r d=u *" Sewer Main Extension: N Private: N Public: N Storm Drainage: N . pr . . Street Use: N , �� cw..,tr Water Main Extension: N Private: N Public: N , `r ;'i' . Water Meter: ilvin n - W �, � �i� � Channelization / Striping: g ** Continued Next Page ** '# doc: Devperm D02 -247 Printed: 09-04-2002 • ' �. 1 , r' S_ V t . ��. 117 �,- . ,sm. R• N '' Cityof ukwlla - , ,,, t t�,W g it � 'F : i doe: Devperm 002 -247 Printed: 09 -04 -2002 ; - -- — - ter- - • , 4. ■ • 4 : } 0 City of Tukwila E . Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 { t PERMIT CONDITIONS Z Parcel No.: 0223100070 Permit Number: D02 -247 ~ z ta • - -- _ _ . . — " - - r _ . • 4 , ���"'t-' w� CITY OF TUXWILA (- ; ; , E Permit Center Project Nutnber: %t: 6300 Soutllcenter Blvd., Suite 100 x`---- '0 Tukwila, WA 98188 Permit Nu b er: (206) 431 -3670 Q Z-V17 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Pro r 6 ,-.. Name /Tenant: Valu f Construction: �r= 19,76R__,, 0 0 Si Ad a dress (includ suite ber) City State /Zi Tax Parcel N -3 a 1 U ' - P'-F I l< 14 7T <u) l9�- 9 : 18 Pr f - ----r r: Pho 7.3 3 ?5 3`a 0 Stree Address: "TT-f- Ci State/Zip: Fax # j�7 (D 71,0 ,So 22 Kul. r� 90'01S z, p 5 G q�r ' Co�cr �. , �tc� x c'N/ -L 1U Pho � G 1 r }�d9-r �, 5 �6 7 / 1 . 5tr,e,�A ss: v 1 I it). DF- i-L' -Y gE Al 0041 #f: 11- c1.6 6 t/ lt Architect: Phone: Street Address: City State /Zip: Fax #: En ineer: ©E57 L#%41 4N HO Pho�te: r� ( . Street Address: City State/ Fax # • Z . ?R6 '4 c rc />4.41/ -TM ao�f - 9 "rfig. q f 3 - 9 ? S �Z Contagt Person: Phone: w 11 ` ft > ,'r /3 ce r L L � Street Addre s• City State/Zip: Zip: Fax #: I Z- v ..C21 Pr gauzvu> : rt - ?Ao0 `� ` f p s `tG Gpl ‘9 0 o u) ° cow Description of work to be done ( lease be specific): W I �PF I X $ odd d ME-7)4i- 1 -� r rat G- to t,01 M - ir✓tz o t..\X X. wo Existing use: gl Retail ❑ Restaurant ❑ Multi - family ❑ Warehouse El Hospital § Q ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office t7) d ❑ Sc c ool /College /University ❑ Other H _ Proposed use: LlRetail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital Z. I- CI Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office I-- I- ❑ School /College/University ❑ Other 2 D DO Building Square Feet: existing No. of Stories: Area of construction (sq ft): 0 - DI_ Will there be a change of use? ❑ yes ❑ no if yes, extent of change: (Attach additional sheet if necessary) w w Will there be rack storage? CII s ❑ no tL p Z Existing fire protection features: ❑ sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) U u) 2 Will there be storage of flammable/combustible hazardous material in the building? ❑ yes no O 1- Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Z APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: , ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to ' �, possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in ! .... Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application . cepted Date application expires: Applica • taken by: (initials) taw Iola / ' PLEASE SIGN BACK OF APPLICATION FORM .' 'S � _ 11 /30 /00 i Amor Ott• clpermil, doc tini m l - :`e>i,S <:�rt, ary.. .... _. n.,.. ,..... .. ... ... .........�aL..,.a.�,..+.t. r .. .... ;.... .a:w ..,.i...;.ur♦ ... �h d1r >:.. .,,+y4u,.. _. .... .rx; aE.+: ..r 'SiN...n7x fdtmr' X. vtw,-,+. i. v( y; r . aa f.nl,�M'4'(+ "�?y pii`t�f" • cr APPLICATIOOMUST BE SUBMITTED WITH THE LLOWING: • ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(S) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) ' 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, Z identify by size and species which are to be removed and saved Z 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) QQ 2 11. Location and gross floor area of existing structure with dimensions and setback J U 12. Lowest finished floor elevation (if in flood control zone) 0 O 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). CO w J = ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled w In w � Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of aj any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site d ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack Z layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of F- O rack. Structural calculations are required for rack storage eight feet and over. w w ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished U p ❑ ❑ Construction details p E- w ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water U supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed u- p sprinkler system design criteria as identified by the Fire Department. w Z U ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. o ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). z ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building OwnerlAuthoriz• : Age t If the ap....cant is other than the owner, registered architect /engineer, or contractor licensed by the State r : of Washington, a notari ed lett •r from t. - prop- ty owner authorizing the agent to submit this permit application and obtain the permit will Lam,' be required as part of is sub ittal `) I HEREBY CERTI Y , I REA i AN ' E • MINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF ; PERI , ' 18 'E • S 0 TH ST TE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING f y / it ' AUT •RIZ•D •.: NT: rev von Signature: I - Date: 5 ,/ e , Print name: - 42 ax Ii: t taw Address I Z 7 ELA Ygia-PVI✓( k' 04- 9 'oo AIM al 11/30/00 IBM ctpermit.doc i' a ai l x,., ,., ., . r .. ... .,.... ..,., " F�wr��• ?x�at�M +c�+�,s��{rr2'�S/.i�At�YPaplc" I I — . _ — '' .Gr �, . x +� I ; �� �� - City of kl • 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z . RECEIPT it 2 Parcel No.: 0223100070 Permit Number: D02-247 J U Address: 230 ANDOVER PK W TUKW Status: PENDING 0 0 Suite No: Applied Date: 08/20/2002 - W U1 Applicant: REI Issue Date: -J I. WO i Receipt No.: R020001213 Payment Amount: 534.56 g M Initials: SKS Payment Date: 08/20/2002 02:07 PM (0 a User ID: 1165 Balance: $0.00 . 2 . Z.,— I— O. Payee: WILLIAM E. LILE w t j + U Q TRANSACTION LIST: p H . i Type Method Description W W Amount H U ; u. O ■ Payment Ch ec k • 4720 534.56 Z w o E-' ACCOUNT ITEM LIST: z Description Account Code Current Pmts . BUILDING - NONRES 000/322.100 321.25 PLAN CHECK - NONRES 000/345.830 208.81 . STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 534.56 i E? , ?T�' ; i . . t ', 11;131At' �, fir; 1 k lit {�, ,. . .. ..2s2 i 17'16 TOTAL L ... fA 1 C ( :', NTITT,Apro doc: Receipt Printed: 08 -20 -2002 t{ . _ - .-- , - '.' , . , : , N. • • Z . • W JU • I - i" - - A. — r - - ,, 4 1 I Z UJ I) re 2 6 ' INSPECTION REC 4+°' U o .- , 0.•po Re a copy with permit `� 7 w = I INS N NO. PE•,yj N y J F. CITY OF TUKWILA BUILDING DIVISION, 0> I 0 o 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 2 Project. E Type f- Inspecti�: S� u_ Address: "- D to Calle — d .2 /MID, e ,/X ,4 It,' /U -9 --D ,;. 1•- W Special Instructions: Date Wanted: a.ma.m. ) Z. H I f., .., e/i-Lt. 0 ! Reques e W W �� /d / 5 /L > Pho No: U 0 r , c- 1 0' 9 <" /—' f/75 — W Approved per applicable codes. Corrections required prior to approval. I U ' + , COMMENTS: H LL- Z 1 / C- -/--- f F. 7--) 1J -i 5 , � , 5 s i': > } 47-.,..4.41/ a ,..., ,--- 4fri, e• 7 /---- ( '&49 ;''''' /3e, 5: te--- (27 da---,c.":5 el ...-- i ,'� '-1 /1-/ ��- 1 Ckry 9 , 1 , 1 5) r ------ f >e,-• eie --' c 5-241/ i , , : .. , , A , 4 d i < Inspector Date: '; f 1 • ✓ 4',01 Vic $47.1 1 • EINSPECTION FE D. Prior to inspection, fee must be is ,au: .:., paid at X300 Southcenter Blvd., Suite 100. Call to schedule feinspection. `' ,', `,, : Receipt No.: Date: , . 1 'ti 1 7 i n - i xGJL..WerC.... + i:.'n. 4 h'.. ..-.n ....'aa :F it - ...: ::'.u• ... .'w.. ..: :..... ,:,, .. ... .. : ^•T ... ... . , .. .... a,1i444wiB9 U;55 A :k.. ,r A,Gzi, t ( +b'. +. r r<1A: , i 1 _____, ` 1 . ' 1777 77 -77,4 "7 - .• . 'r . • ` . ;:CP',r , ■)■Fz; t, :V r }f1.' 'd ..`.c'4W'iili;k.V OP;;{!' S { C •L'N*'aifF`''''..%)%A. d`" ,. . " ,. • _ r r ' � Li4,,,‘;`, �• 11A , • . 1 • City of Tukwila Mullet, Y S tev en M. Mullet Mayor . a _ ; Fire Department Thomas P. Keefe, Fire Chief 1908 _ , z • ~w TUKWILA FIRE DEPARTMENT _JO FINAL APPROVAL FORM U co 0 w = Permit No 2.16.. N O w ga w¢ • W: • . = d • , w . �� z x j Pro Name ._. I- O I ,� tt � Z I-- Address C - .S U r C�.U� *ir (k %\---) , Suite # w N 0 I-- i Retain current schedule - - -- = v . rz ' , : Needs shift inspection )40i • " z w • U 0 Approved without correction notice Z Approved with correction notice issued J Sprinklers: Fire Alarm: . . Hood & Duct: • , . Halon: Monitor: . • Pre -Fire: Permits: . t Authorized Si tur Date •' ' gkS:A ff FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 •r J. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 F ± . , . M.. _ „a 1 ` . . . .. . �.' . . .J• t By G. GHANIAN R� `{ DESIGN & ENGINEERD CO. 1 DATE 8 - 15 -0 2 3786 LA CRESCENTA AVE., SUITE 204 SHEET NO. GLENDALE, CA. 91200 JOB NO. RD -7106 SUBJECT . . . TEL:(818)957 -2980 FAX:(818)957 -8603 Z j „wy st A I t 7 0 M.12 t Wirtit 0.1 ' 0 . ., s ..... ....; ... ... ... rrrrvs- e . wn.- n+ yr..noyY {�A1R1•'�7T1PY�14t+YARK r t..z.1.1..c.,„ �. a `. .- . . _ I - 1 . . — , .— - • ,. - r • - • ■ _:s-, re • BY G. GHANIAN EL ,‹ DESIGN Sc ENGINEERII` CO. `, D .. 8 - - 3786 LA CRESCENTA AVE. SUITE 204 SHEET NO. 2 GLENDALE, CA. 91208 JOB NO. , .. RD - 7106 SUBJECT . , TEL:(818)957 -2980 FAX:(818)957 -8603 , . • .i BY G. GHANIAN--, 1 / < DESIGN & ENGINEERID CO. DATE 8 -15 -02 3706 LA CRESCENTA AVE., SUITE 204 SHEET NO. 3 GLENDALE, CA. 91200 JOB No... RD - 7106 SUBJECT , .... . TEL:(010)957 -2900 f AX:(010)957 -0603 • • SEISMIC DESIGN Z k Q 1= V= 2.5xCaxi W ' ,� Z x UBC 1997 SEC. 2222 W Rx1.4 WORKING _L_ONGIT. SEISM BY G. OHANIAN • DATE 8 -15 -02 SUBJECT , R[`'Th{ DESIGN & ENGINEERIP CO. 3706 LA CRESCENTA AVE., SUITE 204 GLENI)ALE, CA. 91208 TEL:(818 )957 -2980 FAX:(818)957 -8603 SHEET NO. 4 JOB N0. RD -7106 MOMENT AT BEAM CONNECTION = .95"K CONN.- 2 .25 z V RIVET . .252x3.14 x80x.4 =1.5 K 4 Ma = 1.5Kx1.5 "x1.33 =3.6K CONN OVERTURNING M0T = .09Kx2x144 "x.5x1.15 = 15 K MR = .80Kx24 •= 19 "K BEAM - :25 "0 RIVET F Y =80 KSI NO UPLIFT TWO 1/4"0 ANCHOR BOLTS PER BASE PLATE OK. - POST BY G. OHANIAN SUBJECT RE 1. K DESIGN & ENGINEER... u CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 RECEIVED OCT 18 2002 BUILDING DEPARTMENT screws base plate to shelving column shear shelf tie long beams I , i m,4,, I` . /At) PERMIT COORD CP PLAN REVIEW /ROUT N SLIP ACTIVITY NUMBER: D02 -247 DATE: 08 -20 -02 • ; PROJECT NAME: REI z . _I- S ITE ADDRESS: 230 ANDOVER PARK WEST re w2 _ X Original Plan Submittal Response to Incomplete Letter# v p o Response to Correction Letter # Revision # _ After Permit Is Issued w = 1— N u. WO DEPARTMENTS: Z g 5 Auk B'Z - b o2• u. Q �t AT � 3- � D Buildi g ivision M Fire Prevention A Planning Division ❑ = w P ublic Works ❑ Structural ❑ Permit Coordinator Z HO z S— W W DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08-22 -02 U m co Complete £ ' Incomplete ❑ Not Applicable ❑ 0 Comments: = W . 1— Permit Center Use Only. lii INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: U S Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PWW❑ Staff Initials: Z TUES /THURS ROUTING: ' i Please Route d Structural Review Required ❑ No further Review Required ❑ . REVIEWER'S INITIALS: DATE: ■ APPROVALS OR CORRECTIONS: DUE DATE: 09-1 9-02 Approved ❑ Approved with Conditions d Not Approved (attach comments) ❑ Notation: ,N, v REVIEWER'S INITIALS: DATE: `;`�'-� ' r Permit Center Use Only 0:1' ! ' CORRECTION LETTER MAILED: ; a, •, '�yyyy� Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW E] Staff Initials: i4' ._ .r . PERMIT COORD COPY � r�, }f az Documents/routing slip.doc -28-02 , a! # , fr Riawi , PLAN REVIEW /ROUTING SLIP • ACTIVITY NUMBER: D02 -247 DATE: 08 -20 -02 PROJECT NAME: REI a • SITE ADDRESS: 230 ANDOVER PARK WEST cc 6 X Original Plan Submittal Response to Incomplete Letter # v o u) Response to Correction Letter # Revision # After Permit Is Issued w CO LL u j DEPARTMENTS: g i co: Building Division Fire Prevention ® Planning Division ❑ Z W Public Works Structural ❑ Permit Coordinator ❑ I Z0 UJ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08-22-02 o i 0 0 { Complete Incomplete ❑ Not Applicable ❑ O — CII— Comments: = U IL- 0 Permit Center Use Only li N V — INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: O Departments determined incomplete: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: Z TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required • REVIEWER'S INITIALS: DATE: • APPROVALS OR CORRECTIONS: DUE DATE: 09 -19 -02 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation:.. • REVIEWER'S INITIALS: t!/L" DATE: Es ezzicra 4 Permit Center Use Only CORRECTION LETTER MAILED: • Departments issued corrections: •Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: AIM .k }".a A •3n...�� � • 2 Documenlshouting siip,doc 2 -28 432 .: ? : ' 11Z4 ,; • . PERMIT NO.: D02 - 2 ? 7 TENANT NAME: R `' i BUILDING PERMITS INSP!CTIONS CONDITIONS , ❑ I Progress Inspection Status a 10001 No changes will be made to the plans unless approved 0 2 Pre - construction by the Engineer and the Tukwila Building Division 3 Investigation ❑ 10002 Plumbing permits shall be obtained through King Co 4 OK to Occupy 0 10003 Electrical permits obtained through L & I . ' Remove Stop Work Order 1 0004 All mechanical work shall be under 3 separate it Z 6 Follow -up 10005 All permits, insp records & approved plans available . 1 I= 10006 All structural concrete shall be special i I-- Z Pre -Move Inspection 10006 inspected W 7 50 WSEC Residential ` ❑ 10007 All structural welding shall be done by WABO certified QQ 2 ❑ 250 Foundation Insulation ❑ 10014 Readily accessible access to roof mounted equipment i 5 0 . 300 Concrete Slab/Slab Insulation ❑ 10015 Engineered truss drawings & calcs shall be on site u. 01 350 Crawl Space ❑ 10016 Any exposed insulation backing material shall have N d ' j (] 400 Shear Wall Nailing ❑ 10017 Subgrade preparation including drainage, excavation I W 450 Plywood Wall Sheathing ❑ 10018 A statement from the roofing contractor verifying fire Z 500 Roof Sheathing Nailing retardant class of roof • ' 525 Plywood Deck Nailing 10019 All construction to be done in conformance w /approved Z O �' ❑ 550 Exterior Wall Sheathing plans ❑ 600 Masonry Chimney - ,1 610 Chimney Installation/All Types ❑ 10020 Structural observation shall be provided for this project U N 700 Framing ❑ 10021 All food preparation establishments must have King Co O - 750 • Roof/Ceiling Insulation ❑ 10022 Fire retardant treated wood shall have flame spread of w F" 800 Floor Insulation ❑ 10023 Notify Building Division prior to placing any concrete z U 801 Will Insulation . ❑ 10024 All spray applied fireproofing shall be special inspected 1- F- $02 Exterior Roof insulation ❑ 10025 All wood to 1 in placed concrete shall be treated — O ❑ 803 Glazing Inspection ❑ 10026 All structural masonry shall be special inspected .. Z ❑ 815 Lighting and Controls r 10027 Validity of Permit V W ❑ 900 Suspended Ceiling ❑ 10028 Rack storage requires separate permit P I ❑ 000 Interior Wallboard Fastening 0 001 Exterior Wallboard Fastening ❑ 10030 No occupancy of building until final insp by Bldg Div Z ❑ 110 Pre -Move Inspection ❑ ❑ 10031 Comply with requirements of TMC 16.04 ❑ 115 Motor Inspection 10032 Remove all weeds, concrete, stone foundations, flat 0 120 Pre -Demo concrete ❑ 140 Pre - reroof ❑ 10034 Removal of septic tanks require approval and ❑ 400 Final-Fire compliance with King Co Health Dept 700 Final - Building ❑ 10035 Contact PW Div to obtain insp for water /sewer connect 900 Final•Reroof ❑ 10036 Manufacturers installation instructions required on site . 3100 Site Visit 4000 Special - Concrete ❑ 10038 A C of O will be required for this permit 4001 Special -Bolts in Concrete ❑ 10039 Final approval for all TI w /in the limits of the SC Mall ❑ 4001 Special- Mom/Resist Conc Frame ❑ 4003 Special-Reinf Steel Prestress ❑ 10040 All construction noise to be in compliance with 8.2 TMC ❑ 4004 Special- Welding ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 4005 Special-High- Strength Bolting ❑ 4006 Special-Structural Masonry ❑ 10042 Fuel burning appliances + 0 4007 S ial -Reinf Gypsum Concrete ❑ 10043 Appliances, which generate M !!!. ❑ 4008 Special- Insulating Conc Fill 0 10044 Water heater shall be anchored h ❑ 4009 Special-Spray Fireproofing 10045 ..Reroof '° ❑ 4010 Special- Piling, Piers, Caissons ❑ "Anchoring - All new construct and substantial �, -. 5 ❑ 4011 Special- Shotcrte improvement shall be anchored to vent flotation" ❑ 4012 Special- Grading, Excav/Fill fi t , ;� .t.; • ❑ 4013 Special- Retaining Walt Z7 Ca - 1; S rt z ` . ❑ 4014 Special- Panels Plan Reviewer Date h . �;, ❑ 4015 Special-Smoke Control System " . ' '1�`�`' Permit Tech: Date: - ) ; l gfif b ., .. , .. , . ., :v: ....4.v2% a'rs.x..Ksx`rt. e.. ,. ...0 . . . ... . .............,« .............. . ......., .. ,,.. , .., . . , . o,. ,., ., ...,:,,.w..r.. ...�„ .... . n + on .A i I - .-- - -,. C r - � 1 ,r..y, , n+ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -247 DATE: 08 -20 -02 PROJECT NAME: REI z . SITE ADDRESS: 230 ANDOVER PARK WEST z re 1 X Original Plan Submittal Response to Incomplete Letter # v 0 0 0 Response to Correction Letter # Revision # _ J After Permit Is Issued . w = W H • u- - W 0 2 DEPARTMENTS: • Q Building Division D g ❑ Fire Prevention Planning Division ❑ = d W I P ublic Works ❑ Structural Permit Coordinator ❑ z I Z 0 W W DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08-22 -02 2 0 Complete U Com p ❑ Incomplete ❑ Not Applicable ❑ O — — 0 H Comments: W W , I- U ! U. O .Permit Center Use Only lL Z INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: N I Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-19-02 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: 4` REVIEWER'S INITIALS: 316 DATE: ' ( 21 0 Z. �'f�'M Permit Center Use. Only fit . N4,, , :41' . p CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ P W ❑ S taff Initials: �.� 1a 707. 04 Atia t f 444-3 Documents/routing slip.doc 2 -28-02 4AM a A.t • d�AMiw +.v..gw«Hnee:K+a .....- ,. .... ,....„....r , ■ -_r - -- • - • • \ ..., • LICENSE DETAIL INFORMATION Form . Page 1 of 1 I . STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: z . LICENSE DETAIL INFORMATION t. �Z re Lii * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * i e „, t ;:14‘ ■ New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or fi °' return to the L &I Construction Compliance Home Page t � .:z: ; ._ . a 1 D O* 7 • „.„,„,„ , / 4 p... https : / /wws2.wa.gov /lni/bbip /TF2Form .asp ?License= DISPLTI988NO 09/04/2002 � A ;�` . - "k..r- 1 1 - -- •■ . ) ,, .. ... ) lj ..... •--- 1 . i - i • • • ' I • . / I • Z . . • I 1" f y Ili -J 0 00 . U) UJ i LAw A ...,... -....'... ',.-... :-..*. :;-•.:..- - to , 1 WI. ....1 1- uj 0 ' /.. 7:--2 . .,!;,...,-• ......:-.-- ....:-.:,,:....;:..,.7.........--.: h-..s:.:'::.s,..-;*4::-:,;.1-..-.... -..:.:*:-.-.1 REGI STERED AS PROVIDED BY i 1 .p.:...• -.:.t!......s.; -:....-:: ..-. 1.,..:•.:•:.,;;; ......:,:: .,,,,,...-!,:-- .4..- ". .,•.- ..:. '''''';'''''''•''.''''''' . • •::". ; ..'''..". '''''' ''''`-•'.-- ----' •,:.',.-. •::f.z - - .-- ' :,.• • .•• . ' " ' CONS T CONT SPECIALTY .. ',, ,.. . ::::-...-.:„....,: ,:•.f.--::....-- .. - .. ..... . . . . D E. a i 1 ,cECFCFGETIDVEISpPLTI988NO -E 0 02 X ; P /2 . 2 0 . ' . 4 . ..... . IMM. W I I Z. I... • I-- 0 , Z I— l DI SPLAY ' TE O LU uj 1 BEL , 12 5 L 7 E E vu V . E E R ' r 9 8 0 0 , • 2 n - • , n C) , . ' 0 co u • • • AND INDUSTRIES . , 0 1 :, . . ..,...... ......;:, ........ ... ......,...:....... . , .... .....‘ , .... .... ... . I Sli DEPARTMENT OF LABOR A 0 I— . i Issued by . ..,.. ... ... . •.. , • -.• • : .- • ..- .. • • • . . ...• . • , _ .... .. • . • a • , • ,.. ., ... , ... .... , • . • • • . . • • . ‘. . ■ 11 Z .., . • • . • . . '0 . • .. LU CO 0- . • • . • .. = I- 0 I_ . Z I , i . , 1 • • fc---: i‘ite . .,....... ....; .,....,,L.#. .,, 6 `4tr,t,IV'tn, g k i kiNikr!" 1 g `4 ; '.,4,),•"4.1,:‘,i>`;':-'`4) I 4:,11's7—‘41, rtr.):0 1,1 D02. 21.17 .....,,,, 6 , . 1••••••01.1P.,MANOMPWk• VP,4"InattriatA W4S.714 ~1104,NIKWIT14 • • ready for issuance bill lile rack storage plan FILE COPY -' I understand that th A Check approvals are subject to errors on sio .n. . ppr oval of plans does not Jthod , V.- via =tio of any adopted code ordin,.r ,e. , ipt f con- - - -,� 1 tractor's cop - 4,, - -d . :ck owledge f j I � 1 REQUIRE A NEV4 PLAN SUB i PRIOR �j I " � 3 0 60 -7S � 30 -80 -75 130- 80 =75 130 -60 -75 � 3C -60 -75 � 30- 60-75 ./A:44 24 -60-6S 1 24 -60 -65 1 24 -6�I8 l i By � Z h CR T T t T J_ J I 1 Date t , ® 1� v h l� c� I I r - - � F r r - - a ERVIC Perini N .. - ` �' ,— i i i i i „ i i,, 1 ( 1i 103 - .. _ ..__. _T .....: G +� � r -3 a �1 I 1 1 ,: I 1 ° i i S 1 I STORAGE t- - -' I - .,; .. ' �"` -, , m I cmi 1 I m I I I I m I ,---- - -J ( 102 J ; ; �� � r. ; ;, , F -- 1----I 1----1 F ---I -T -, I I N o CHANGES SMALL BE ' MADE TO ;4; m i k i i 1 1 (T i i I T 24 -60 -6S I 24 60 -6S I J L_ r�C��E '�� `��� � '�' I� � �;,; \ j � � I i � . i i � i i � i � � i >� °" OVAL OF TUi1 WILA BUILDING DIVISION. � � 1 I I 1 I r I I I -- ATE REVISIONS W ILL SUBMITTAL f ,,,� , I F'- I F-- F-- F-- I A 'PAY Pa:L OE a4IDITinx.=.dt, Py;AN fiPKIEW FEES, — c'"`• °` I z _ _..___..... _ J I I I I 1 I I I I it { 1"I r r—„ -- , , I? F , I I I im, p 24-48- 7524- 48 - I 1 I I I I I I VENIp1; V'EN ' ( 1 L J L J L J L J F;' 48 -72 -4S 1 48-72-4K 1, 1 1 1 I I ICI I I ILI I 3a -- ) 1 I p r - T -- 1 r - -- 1 r - -' r --1 r - - - •� i - - -- '. - - - i r -__-1 r A °r'-1 iii ; `� w al rn m m i I r ____ - _ rn L - -- m 1 m Lit r�1i 1 vin f I I fo I 1 1 I f Q L - -- I-- -1- --I I- - --i I- - --I I- - --I I - - - --I I- - -- I I- - -- I I - - - --I 1 - -- -•1 r r ii__ r r --- - -, n, r, j u.) �, `�' f n' b" O I 30 -60 -7S 1 30 -60 -7S r 30 -60 -75 1 30 -60 -7S 30 -60 -75 1 30 -60 -75 30 -60 -7S 1 1 30 -72 -7S 1 n If I 1 Y `r 1 I 1 I. TI 1 1 1 1 1 1 I 1 1 1 30 -72 -7S 11 " ,� N N N N m L � I I 1 I I ( I I I I N N � � N 1 1 1 I I 1 1 L J_ J J J__ =i/ J L L 1 -II a1 m m m m , -, � 1` L -_J L__ L _ - L ___ J L __._ J L___J L —_ —J SKI STORAGE � _ _ _ I I •( I r T T - r -- r - -- r - - _ - 1 r - -- 1 mr - - - I ' r 1 r —1 8C AI-51- 1 1 L T - r T - ---H 1 I I i I I I I i I I o f I t I 1 I I 11 1 1* 1 1 I r T - 1 I t. I I t 1 t& I I I r '•t -r T T -- r T T T T T T T T 1 I I I 1 - I I 1 11 T 1 I T 1 I $ 1 I I 1 I 1 I 1 1 1 1 1 i I 1 I I 1 1 1 1 30 96 I 30- 98 - YMC ' ___ 1 _L__1_ _J1 11 1 t I w I 1 � X 1 1 1 I -80 -75 130 -60 -7S 1 1 X 1 I � I I X� 1 1 1 1 30 -72 -7S 1 30. -72 -75 1 30 -80 -7S 1 30 -80-75 1.30 -80 -7S 130 -80- 75130 -60 -75 130 -60-7S 130 -60 -75 I30 -60 -7S I:30 -80 t - - -r - -- J 1 1 1 1 1 11 N I 1 Vl 1 1 1 N 1 1 1 ! 1 N 1 1 Vl 1 L LA 1 11 1 1 . -. , T '' \-J _ .... - - )' T__ _ , + ----q - ..._._. _.. R — •6 -y G = — — I S1a /z;s)ib C ._ _ - _.. ----- . -. It .� a1vc, ....._ __ _._— .._ -_ _ s si n. n. , ._ __.._..— /_ siteLW%,' Ao / r It f1L I I ) I nr ' FeR, I LT� yR / LJ.Dt 1 rx n r m:LV r - I _ _ _ _._ _ � r ' ,..,....,,,,,:,...„,..,, WV I — 4Y 2.,..q" _ 1 l . , .. .vacu - _: Y we+.= ; - -L:L_ — As z" z I „ , vi, 49' ,_,_ ee > z^ 7y' ' I @ I� I 2 -•IB'7d -I _ -_— , ,, ,, )MVE J-)2-NlS ew F1F ,n , pp.ler•a = S " /L ,Jet iJ+l F4( 1 1 t a ±L I, , `— - ?� - { INC .LU 14.3 CFotEh 6881.F.nn P/UlT>S ALL LG11(l. d � yi I �� ?a S)eLF f ob 1 9)` v� ` ` y �� r , ,m 1 � . � RECEIVED ., i P8.sr)F1F . — — CITY S ��rt� , EYY11,.4e vj 4 3 as= ,f' / L I ` " AUG , ")[ ,F Plj .sT{E Lt ! PB v ' U I4 `.0 4 1 7 1 P 0ATAI, . 6 4 i � , �R�I� Eq all E \FIRES 12_3 (_ 0 2 ' _ - - .,,pa 3NELt f 3 1 6 Pe 7 I 14 P { 9e,+alzP 3z �� ...- 4z R- -R I L ( .8., H ToP I 3 1 % I -_— y , ,1 r— �' z,,,./7 )'G : n _ -- 4 ... %,, 1 goy 3 k 'le' 01z (n R( P j -7LpN7- ErJb SCALE ( 'APPROVED BY DRAWN BY /ILL A c R ' DATE ,i . _. REVISED .. L:a6-4fl -N13 T�j • k -W f f3 . I *L 7G-7� /ILL cUrJy 1, $0 - 4N 0C - 12 ' DRAWING NUMBER 1 I . , 14'.''.,4 , 1 I ; - EXPIRES 12 -31 -02 1/4 "0 RIVET ASTM A345 -79 "T" POST Ci BEAM CONNECTION (2) BEAM SECTION O3; CENTER SHELF SUPPORT (4; #12 TEK SCREWS -BASE PLATE (2) 1/4 "o ANCHOR BOLTS PER BASE PL. 2 " EMB. (SEE NOTE NO. 3) BASE PL. DETAIL ( BASE PL. & SLAB CONN. 7 NOTES: 1- DESIGN OF STEEL STORAGE SHELVING AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE UNIFORM BUILDING CODE 1997 EDITION 2 -STEEL FOR ALL SHAPES FY-4-36 KSI. ASTM A570 -85 GR.36 (EXCEPT AS NOTED) 3- ANCHORS WEDGE TYPE, HILT! KWIK -U ICBO #4627, RAMSET REDHEAD ICBO #1372 (NO SPECIAL INSPECTION REQUIRED) 4- CONCRETE SLAB 5" THICK 2000 PSI. SOIL BEARING CAPACITY 1000 PSF 5- STORAGE SHELVING CAPACITY 250 # / LEVEL 6 -ALL SHELVING INSTALLATIONS AND SHELVING MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS„ A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD OF NOTE NO. 6 7- STORAGE SHELVING SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1" IN 1O' -0" OF HEIGHT CTR EOCNW AUG 2 0 2002 PERMIT CENTER REVISION RACK DESIGN AND ENGINEERING 3786 LA CRESCENTA AVE. #204 GLENDALE CA. 91208 SCALE: NONE DRAWN BY —4..X-41 DATE: 7 -21 -02 PROJECT: REI — TUKWILA 230 ANDOVER PARK WEST, TUKWILA, WA. 98188 TYPE "A” SIDE VIEW TYPE "B" SIDE VIEW STORAGE RACK DETAILS JOB NO. SHEET NO. RD -7106 1 OF 1 EXPIRES 12 -31 -02