HomeMy WebLinkAboutPermit D02-361 - SPECIALTY WAREHOUSE - STORAGE RACKSSPECIALTY
WAREHOUSE LTD
530 ANDOVER PARK
WEST
D02 -361
, - - - �.Cr ti
0.:44%A. IN : .3411 "
t : L •, City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
DEVELOPMENT PERMIT '
z
i d
1 Parcel No.: 2623049015 Permit Number: D02 -361 1 W
Address: 530 ANDOVER PK W TUKW Issue Date: 12/11/2002 6 5
� Suite No: Permit Expires On: 06/09/2003 W U
00
■ Tenant: W
Name: SPECIALTY WAREHOUSE, LTD W 2
Address: 530 ANDOVER PK W, TUKWILA, WA to
WO
Owner: 2
Name: ROFFE & ASSOCIATES Phone: 206 244 -4200 g 5
I Address: C/O ROFFE INC, 415 BAKER BLVD, SUITE 200 N d
1-W
Contact Person: Z =
Name: JIM SWEIBERG Phone: 206 575 -2445
1 — 1 1.- Address: 530 ANDOVER PK W, TUKWILA, WA Z O0
WW
Contractor: v p
Name: OWNER AFFIDAVIT ON FILE Phone: p —
i Address: , 01—
Contractor License No: Expiration Date: = U
DESCRIPTION OF WORK: LL O
INSTALL PALLET RACKING /SHELVING W z
UN
O H
z
Value of Construction: $0.00 Fees Collected: $43.28
Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997
Type of Construction: Occupancy per UBC: 25
Public Works Activities:
Curb Cut/Access /Sidewalk/CSS: N •
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation: N -
Moving Oversize Load: N Start Time: End Time:
1;
Sanitary Side Sewer: N ?.,-� : ;
Sewer Main Extension: N Private: N Public: N ' ' „ `'''
Storm Drainage: N N
: � ;.: �
Street Use: N rtir;'.; r%
Water Main Extension: N Private: N Public: N
Water Meter:
Channelization / Striping:
** Continued Next Page ** .
i tr i.. „ ,00 , 'f,':1 i
doc: Devperm D02 -361 Printed: 12 -11 -2002
"Z i;s11 t
•. �: v: G1Mii ✓.::.:.:..�auiwl:.:.�lv.:,.ti :<', r:: n,.ia,LJ:u...�: v•f v+ LmiwJttewatanxw .4uwwnr+n..vws,+e•rw„.. w.4x qw- r.. m- n.. n. n. ...c.,.....:....x ............. ............ ... .. .. ... .......:................... n......., , ... r,..:..... a-. �r:.. rv. e. wrrti. nw. a», 9+ ,wrM�ywen,m,s..rw.,.,a..:.v.+.
4
t
,
fiJ---
-r - .-- - -- k .c-r - .1
r
..
:`
1
ti INt, '''''..) .0.,..
g of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 '
■
3
I
Z
Permit Center Authorized Signature: sh, . A.A A1.,A _`7 .A. - Date: 1 t9 1 i -6 2- : l Z
�w
1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
1 ordinances governing this work will be complied with, whether specified herein or not. . o
CI
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws u) w
1 regulating construction or the performance of work. I am authorized to sign and obtain this development permit. _1 f
;; Signature: s, a.� % 4 s Nina Al - w. :.. Date: /2- fl . w .
Print Name: 7/ v1-/ - to d
I mo- w
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is Z H
I suspended or abandoned a period of from the asnspecon. 1- 0
{i dd bd d for id f 180 d f th last inspection.
Z I-
1 2 ?
f U 0
1 o
wW
1 =U
1 IL O
Z
w
F- F =-,
i z
i
';'( fir ;:;.:.,11;',,.,,;,w,
,
1 V r it,..
t!.,,.. +
' doc: Devperm D02 -361 Printed: 12 -11- 2002 „. � "� ' t
y 6, 1 ,. , ,..*•_..».........,., -..- .wwuxw.+.... -.am w,.r+e n.awv . .,«.., T.-... ..,..- ..,...................... .. ...-� ._- _ n .... ...... . ... —. --. w«.,, ee..-•. w+ e<. aos,., asn, wrnwurexas. a.,. vnv. waauwHanxtnuxn.u+h'64a+H1kR4fi�
. - 4zr
ti
:\
'''''''N
4 g City of Tukwila
Tgois
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
z
Parcel No.: 2623049015 Permit Number: D02 -361 ,I- w
Address: 530 ANDOVER PK W TUKW Status: ISSUED CL j
S uite No: Applied Date: 12/04/2002 6 U
Tenant: SPECIALTY WAREHOUSE, LTD Issue Date: 12/11/2002 0 0
u)
J =
1: ** *BUILDING DEPARTMENT CONDITIONS * ** to u_
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. • w 0
,. ' 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any 2
construction. These documents are to be maintained and available until final inspection approval is granted. g Q
4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 N D
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). z w
5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be Z H
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any H O
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this z I—
code shall be valid. u
6: ** *FIRE DEPARTMENT CONDITIONS * ** 0
7: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following 0 N
concerns: 0 !
• 8: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. = U •
9: Maintain fire extinguisher coverage throughout. H- r~
10: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 LI Z
sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to w co
any fire extinguisher must be 75' or Tess. (NFPA 10, 3 -1.1) H =
11: Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or 0 I-
wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with
the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more
than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less
than 4 inches.
12: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be `
identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard
10 -1)
13: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) •
14: * ** EXITS * ** - UFC Article 12
15: No point in a sprinklered building may be more than 250 feet from an exit, measured along the path of travel. (UBC •
1004.2.5.2.2)
16: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible
route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) ,:.:,.. , .,.
17: * ** SPRINKLER SYSTEMS * ** - UFC ARTICLE 10 -NFPA 13 p ;A '`
18: Sprinkler protection shall be extended to all areas where required, includin g al encl osed areas, below obstructions 1,
•.
and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1) ,s " ' 1
19: Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess ,, , 's {{ {_
of 4 feet in width will require installation of sprinklers thereunder. ''' , " ' tr
20: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila 11 q
Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) ti
21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and ;MOW
-
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler a �,.,
` 7
• systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk f. , ,[ k •
• Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal • ,.‘;.
doc: Conditions D02 -361 Printed: 12 -11 -2002
r
wrt- auxr« uw,. na.. ns. WU+...,.,.,. n...,....,,:,... ..,,.......,. «:.....r .:. ....... ........................ ..um.a.a•.+ur,.. »..,...0...... ,..... , . .. .,.. , ........ ..
r
-- r- • - - -.s.,
i' ,.... ')
.„. :, _---.),, 1,,., f ') Cit y of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance
s #1901) z
22: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance
#1900 and #1901) ;F- W
23: ** *STORAGE PRACTICES * ** - UFC Article 81 @ 11 ye 2
24: The critical storage height for high -piled combustible stock in closely packed piles is 12 feet. (UFC 9.110) Storage J v
above 12 feet may necessitate increasing the sprinkler density to extra hazard and adding smoke removal capabilities. 0 0
(UFC 8101) (NFPA 231) 0 C
' i 25: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or W m
ii—
combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such
as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 w 0
feet. (UFC article 2, sec. 209 -H) 2 •
26: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following g d
methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall N d
sprinklers at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila =
Fire Prevention Bureau. (NFPA 13) Z m
27: In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space O
between loads or at rack uprights shall be maintained. (NFPA 13) w I- '
28: Depending on the classification of the commodity being stored and the size of the storage area, smoke vents, small hose W
stations and curtain boards may be required by Table 81 -A of the Uniform Fire Code. Contact the Tukwila Fire Prevention n o
Bureau for further information. O CO
29: Racks designed for high -piled storage must comply with section 2207 of the Uniform Building Code. Please contact the (31--
Tukwila Building Department for details pertaining to design and installation standards. . •
30: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of i - r v -.-
such condition or violation. u. O
31: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at tii �.
(206)575 -4407. U =
~ O ~
z
1 hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances ;
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work. f
, 1
Signature: iw ._,,,_,, c a X Qj.-er -� 0-! Date: i 2 //( 1
Print Name: �$ 1 rtl c >(..3 F / 73 r' re_ /}
PV; .( 1
0 344, 4 f y ,Y
i Z
mi i •.
doc: Conditions D02 -361 Panted: 12 -11 -2002
F�� 4
«
x' 1.....: .. -x:r ^.•. ::.n•.. +v +: i...r .. ... „... .c ... •..- ., xxMnaykx}MKV.. MI.
f,• .. J'Y. .e. arr* i:• fi ?.x;.a•+ty7�+axtw. ....... ............. .. .. ... .. ....,.,,- ' >annvRawaw.....w....... ... .
1
i '
-
' IJ 11741 w
" -/+ . CITY OF T UI0WI LA i
4 o Permit Center Project Number:
0 = 6300 Southcenter Blvd., Suite 100
.Nk• 0 Tukwila, WA 98188 Permit Numt
(206) 431 -3670 �` 1
Commercial / Multi - Family Tenant Improvement / Alteration Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
Project Name /Tenant: Value of Construction:
Gpecialty WarPhn»sP, Ltd, $250.00
Site Address (include suite number) City State /Zip: Tax Parcel Number: ,�
r,ln AnrinvPr Park WPSt, Tvikwi l a, WA 98188 e11o.2JOY- 92/. '
Property Owner: Phone:
Roffe & Associates LLC (206) 244 - 4200
Street Address: City State /Zip: Fax it:
415 Baker Blvd. Suite 200. Tukwila, WA
Contractor: Phone:
splf — Ji SwP1 hPrg (206) 575 - 2445
Street Address: City State /Zip: Fax #:
530 Andcv ^r D,rk Wogt, TukT WA 98 RR (206) 575 - 2446
Architect: Phone:
Street Address: City State/Zip: Fax #:
Engineer: Phone:
Basi 1 T_ Kati a
Street Address: City State /Zip: Fax #: Z
� Contact Person: Phone: Z W
Jim Sweiberq (206) 575 - 2445 CL g
Street Address: City State /Zip: Fax #: D
530 Andover Park West, Tukwila, WA 98188 (206) 575 -2446 0 0 0
Description of work to be done (please be specific): V PS W w
C &4 ea 1.262.. — 1
Install pallet racking and shelving U)
W
Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ® Warehouse ❑ Hospital
g ❑ M otel /Hotel ❑ Of fice t.
❑Church ❑ Manufacturing N
❑ School /College/University ❑ Other = C!
I--W
Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ® Warehouse ❑ Hospital Z I-
❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office Z O
❑ School /College /University ❑ Other W
Building Square Feet: 3_6 existing No. of Stories: 1 Area of construction (sq ft): 0 u)
O—
Will there be a change of use? ❑ yes ® no If yes, extent of change: (Attach additional sheet if necessary) 0 1—
W W
Will there be rack storage? yes ❑ no
H
n �
u " 1 6
Existing fire protection features: ® sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) di z
U —
Will there be storage of flammable/combustible hazardous material in the building? ❑ yes ❑ no • H
Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Z
APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING:
(Additional reviews maybe determined by the Public Works Department)
❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling
❑ Fire Loop /Hydrant (main to vault) #: Size(s):
❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation
❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public
❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only
❑ Water Meter /Permanent # Size(s):
❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ,
=
El .-..,-•
1
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to
possible revision by the Permit Center to comply with current fee schedules. '_t ;
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The
building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in
Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. ' -, ;
Date application accepted: Date application expires: Application taken by: (initials)
/0 -- ( 1'0 7 -- , -47‘:-03 CGS NNW 11.3■
PLEASE SIGN BACK OF APPLICATION FORM 18111/ 'OM
1/30/00 i
clp rndr.duc ' ;
� `�
,.,.,
. .. ¢.. ,,, .,� °.; xa..e •II iA' .. -.. i . ,w.x.� wed, +t^'n° r�mar., -w., ,.w....,.. ,.._s.,-
... 'i:...:1' +. :. .e.. e. y� ; N,.:.j..•{�CIX ;Y• "t uII l�i"FR.. ! " �' Y .# 1 M4M:u .Y .. .... . .. .. . ...
r . .
-- r _ . ..
1 .
APPLICATI t . MUST BE SUBMITTED WITH TH. I LLOWING:
• ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL
ENGIN, R C R.CLYIL,ENGINEER
. , ;4 4 , 'r ,
ALL DRAWINGS SN BE AT A LEGIBLE SCALE AND NEATLY DRAWN
• BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ ❑ Complete Legal Description
❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Four (4) sets of working drawings (five(5) sets for structural work), which include :
❑ ❑ Site Plan (including existing fire hydrant location(s)
1. North arrow and scale
2. Property Tines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas
5. Recycle collection location and area calculations (change of use only)
6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use
only)
• 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, Z
identify by size and species which are to be removed and saved F Z
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use
W
only) 2
11. Location and gross floor area of existing structure with dimensions and setback J U
12. Lowest finished floor elevation (if in flood control zone) U 0
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). u) W
W
❑ ❑ _
Floor plan: show location of tenant space with proposed use of each room labeled i
❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of
w 0
any hazardous materials; dimensions of proposed tenant space.
cG
Q
❑ CI Vicinity Map showing location of site 0) d
❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack Z H
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of F-. O
rack. Structural calculations are required for rack storage eight feet and over. w t—
w
❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished v p
❑ ❑ Construction details 0 H
w W
❑ ❑ Sprinkler details- details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water H U
supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed t6 p
sprinkler system design criteria as identified by the Fire Department. Iii Z
=
❑ 71 U
Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. E_
O
❑ El SEPA Checklist - if intensification of use (check with Planning Department for thresholds). Z
❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
land use or SEPA decisions.
❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of Public ,
Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5)
❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor
has been selected at time of application a copy of this license will be required before the permit is issued
OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ".
Building .Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State
of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will
be required as part of this submittal r �' 1
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF ' - ' ;
PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGEN : '' • , °
Signature: • /� c.�. Date: ame
e' December 2, 2002
Printnam J er \ J(s ueiberg, Jr. ' r ear 575 -2445 (`d 575-2446 °
Address City /State /Zip `
530 Anr3ntr:r park Wort Tuivaila, W& 9818 r ., IMO
L j
11 /90/00
crperuiir.doc ��
La a
°
.uo.awt w.ero'avrlM! rr.* i:. r« r.••.,.... w........< w...... ,...• ..............a....,...... ...- ..........yewNrd:Pssc'"y�`we, .,..,vwe.�w .. v..., ,.KeaAYcNYev.�,tY. w:%M' 445- 1111 .+N.Yl7:RarX ^,tdiK'M++7nse,. ulwy;5np. * -a.�,
.
, ..
w
;\
 ? ' -14N, s•
� C of a
90.
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206)'431 -3670
i
z
RECEIPT = Z
�z
I IX 2
I Parcel No.: 2623049015 Permit Number: D02 -361 V U O
1 Address: 530 ANDOVER PK W TUKW Status: PENDING u) 0
, Suite No: Applied Date: 12/04/2002 W = ui
Applicant: ROFFE & ASSOCIATES LLC Issue Date:
co u-
` , WO
. 2 �•
' ; Receipt No.: R020001672 Payment Amount: 43.28 g
- Q
u
Initials: SKS Payment Date: 12/04/2002 09:40 AM = d
User ID: 1165 Balance: $0.00 F- _
Z I-
I- 0
Payee: SPECIALITY WAREHOUSE LTD w LU
U D
N
TRANSACTION LIST:
0 l-
Type Method Description uJ w •
•
Amount H U
u_ ,S"
Payment Check 5036 43.28 Z
tii
N
H
O
ACCOUNT ITEM LIST: z
Description Account Code
Current Pmts
(
[ BUILDING - NONRES 000/322.100 23.50
PLAN CHECK - NONRES 000/345.830 15.28 .
STATE BUILDING SURCHARGE 000/386.904 4.50 .
Total: 43.28 -
C ri,4
L ham I
it
3137 .12/0 9 9710 TOTAL 43.20 q/ h O
doc: Receipt Printed: 12 -04 -2002
1 L' ' I;
. .. .. ..'..e... . J .... ..............:................ v.. ... r.mrrw•..r..w.w.uur."...r.v. ni..r.v.•rwru....rnvnu..w.»..
4
i
► •• ' - . . `. ..,
;`
■ Z
~ W
CL .c
Q
gig co O
4 ' . , •__ INSPECTION RECORD w w
z
' Y ° " . Retain a copy with permit
✓ Q� ' ' 1 a J
1-
INSPECTION NO PERM • / N O
• CITY OF TUKWILA BUILDING DIVISION - A
UJ
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 3670 g 5
:L4 abt\/ / Type of Insp on: /J — 0
,, Add ess: "! Date Called: ( W
Special Instructions. Date Wanted: a.m. z O
Y Requester:`r C �� 2 D uj
t J ,
' Pho o : : 01—
Phone
-.5-75 - a yq5_ =W
K U
pproved per applicable codes. 0 Corrections required prior to approval. U. O
: `. COMMENTS:_ Z
, :i . , U ? or ' -1-- ri ( -(
z
e5- -1- o = r t.J ,4-- 1
1
� {
i .
i P:,‘',; . .', 4 -Y75 , ' , .i,
Ti
}
I d 4 .
,r In pec r:. Date: ''. x-t,'; 7r
\,/ (vs-.J.--, Vv.. ��r1 c,.. -Act. /57) /c ,
$47.00 REINSPECTION 4 REQUIRED. rior to inspection, fee be ° . ,Ny.• :
paid at 1 300 Southcenter Bl l
.. vd.,, Suite 1 0. Call to schedule reinspection. j
r eceipt No Date: ,;
t ;„„ , 1,. ..+l3Ux w Y rD 0 .,.- 0.4,4, lrAo.,`ts. A.,c,+i tb Y , 1'h'bt
+
-. . ,...,
■
:`
• Z
i-Z
�W
t...- Agit....„-0..1.4^.4......s ;-- ))zA ( A ,/ ...ip; t,., ,
,
E
{ . t• ' i ^ a iiii 1 r5 4 •
ilk ector:
\ Date: ,u
10 0 t k ' S
47.00 REINSPECTI N FEE REQUIR . Prior to in fee must be v r r
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
x#
e eipt No.: Date: ' �. .. %'
....: •. . _ ... ` ." :. 0.;.:,;.�.•, • . 'Y = ;�ti'4'; A y .,,: �r< <J �r r:�.,.� .-.! „• d, y^e:..r t' . >., v�, ; •: A _
r t .�., 1 , +`? r! ) 1ri t : »,F?+ '. . x. .i.: ' ,, , - ; � . S n „ x • • F, . i r ,,., �• i �, '! M. ,' arr ,1
"`4i
� ,• ,� ;!... X•!.' - 4•'1 f. u .. •5 . ab.+•1,•_i i >AFnu� to
:a ,:. � '•^ ro �4. L,r �1`r! .v ,', ..� w. � .. . "i,i' r � :i�.e : • , � W. r, �h. Y. C .�da.,�.avk.�i'�•�,akx;xruiu�at 4.. ^s�,+:Y� r.,:�7h�. ?� "e. '.C,:�: ;t„r�' $:
-' .- , -- k c r -..,
. I
)
'' ' ' '.■ ' -,‘ . . : 7 7' --- 7777 - 7,7177.T .. 777 . 77 : 77,7 7- 7 . ' .
.../.0.7.................. ■1 .... it
a , A r ......
ta AI, ••• City of Tukwila Steven M. Mullet, Mayor
,
% < I Ifi N 401 j — I ;
ii 133 i. agy.4,
',, tp *** ................. I -: Fire Department Thomas P. Keefe, Fire Chief
..----
z
< .
m 1-
. - 2
6 m
TUKWILA FIRE DEPARTMENT _1 0
0 0
FINAL APPROVAL FORM w a
co ui
WI
1 _1 i_
Permit No. 0 C I
1 2
u. <
0
I ci
X
Project Name c ,o// / U../(t.c 11 fJ) 4 - i ti I— 0
.....-1 i Z I—
, LIJ u j
Address ....S A J.-14/(),/( ..- A.: (4) Suite # 2 D
D 0
. r. 1. 0 u)
1 i •••
. s • , I \
' -- \ t ) I 0 •—'
O l'•
V
. .
Retain current inspection schedule ..._ . ..__ •
,
Needs shift inspection - 0
z
W
O u)
1 .7,
, 0 1—
),<' Approved without correction notice Z
I Approved with correction notice issued
\
•
i Sprinklers:
I Fire Alarm:
1 Hood & Duct:
Halon: .
Monitor:
,
Pre-Fire:
Permits:
- , , A
-- t if: ,,,,:20 11 ) /( ,'
../ **-`.-. 1/1 t L.,' \ 't / ,.) - / - L) ',)
Authorized Signature Date I TI;A•WA
-.Intik
;IL, n t
FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85
olowinw:
, fr$
1 liAglat.':
, .
. . - ;1
43, .
.. ,... . .
: Att4
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax 206-575-4439
. -1E 0 2
,. _.. _
,
r ,
base plates slab and soil
all base plates
thick slab
soil bracing
longitudinal direction
brackets and standard a welds
bracket seismic
columns
cantilever racks
axial load only
rack dead load
cantilever rack load
`'`
\IIILA
, W
t � l City o Tukwila , . 0 Steven M. Mullet, Mayor
',, \•. ked .:: : Department of Community Development Steve Lancaster, Director
190B _-- .
Z
May 12, 2003 1 Z
JU
Jim Sweiberg 0 0
530 Andover Pk West W
} Tukwila, WA 98188 J =
F-
RE: Permit Application No. D02 -361 N u
530 Andover Pk West '
est O
i
Dear Permit Holder: g n
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila N =
d
Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the H =
Building Official under the provisions of this code shall expire by limitation and become null and void if the Z
building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if — F-
the building or work authorized by such permit is suspended or abandoned at any time after the work is O
Z
commenced for a period of 180 days. W
U Ci
Based on the above, you are hereby advised to: co
p I—
• CaII the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final W
inspection. '= U .
~ H
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit u_ Z
or last inspection; or if the project should be considered abandoned. LLj
N
U —
} If such determination is made, the Building Code does allow the Building Official to approve a one -time H .
extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why Z
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection or request and receive an extension prior to June 9, 2003,
your permit will become null and void and any further work on the project will require a new permit and
associated fees. ■
Thank you for your cooperation in this matter.
1 Sincerely, •
:
Stefania pencer
Permit Technician
rkk FA
Xc: Permit File No. D02 -361 1 �'�, ' \'' t
Bob Benedicto, Building Official '' i lki I'
1 i 1 } 1
La
i ;'
; ri . I ,%
j
'
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax 206 - 431 - 3665 '4 '' 1" ,r � 7 '
;if, r .. .._. . .., ... , . ..:+. :F<'nra.,.,.._..��,.ilv,.rJewY „s.nt n . .t .�,r.e'. -•; ta..' u.w... r w.,,e..n....... :,....,.... .... ., .. .. ,.. �...,. M. ,...,.... .,..,.,....,_ ww:...r..e «....a,rx....n- .. .. aa:, .. ...- nraaa.�.eM. .,...
i
•
raj .
, - .
�.� r
:\
I
JX
EMIT CO V RD CC(
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D02 -361 DATE: 12 -04 -02
PROJECT NAME: SPECIALTY WAREHOUSE, LTD z
SITE ADDRESS: 530 ANDOVER PARK WEST z
ES cc w
X Ori ginal Plan Submittal Response to Incomplete Letter #
8
0
Response to Correction Letter # Revision # After Permit Is Issued w = Lii
J 1_
CO W
I -, � ' W O
2}
DEPARTMENTS: g J
Buil Division n Fire revention
] Planning Division ❑ = Cy
W
Public Works ❑ Structural ❑ Permit Coordinator Z i-
t— O
1 Z !—
al
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -05 -02 2 0
0
Complete [r Incomplete ❑ Not Applicable ❑ O —
i 0'-
Comments: W w
I i_0
Permit Center Use Only W Z
N
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: H =
0 1--
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Z
TUES /THURS ROUTING: '
I Please Route D Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
1
I
APPROVALS OR CORRECTIONS: DUE DATE: 01 - - •
Approved ❑ Approved with Conditions I Not Approved (attach comments) ❑
Notation:''
REVIEWER'S INITIALS: DATE: . ;
�fY atAi
Permit Center. Use Only ` til: fit,
CORRECTION LETTER MAILED:
A
Departments issued corrections: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials: 3'r, vii, .
. 4 fi5:t `'
PERM _ ��i�'Et�ts"Siy.
P EMIT COORD COP'( , �..:R�.
•
Documents/routing slip.doc 1 .`+t:.
'
2 -28.02 t
a+3'!�
r
t '
,
:■
i
0�W '.. •44y CITY OF TUh WILA H.4
`1, R ,,,:\ w Permit Center
N "fir) `• 2 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188
k 8-' # Telephone: (206) 431 -3670
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
z
STATE OF WASHINGTON ~ W
2
) ss. 6 D
COUNTY OF KING ) i; o
co im
J =
JA «'► F ) (4i � i. � ( \ (� F—
r F ( zz � , 2 � states as follows: A � ,� i �v(z S E ( � �� / � o
w
�ARCNovs 2
1. I have made application for a building permit from the City of Tukwila, Washington. LTD g a
2. I understand that stat law requires that all building construction contractors be registered with the = d
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Z
Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have ; o
read or am familiar with RCW 18.27.090. W F-
2 D
3. I understand that prior to issuance of a building permit for work which is to be done by any o N
contractor, the City of Tukwila must verify either that the contractor is registered by the State of o I--
Washington, or that one of the exemptions stated under RCW 18.27.090 applies. .w w .
E- U
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby - z
attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I Cu co
consider the work authorized under this building permit to be exempt under No. / :A , and i I
will therefore not be performed by a registered contractor. z
z
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to
engage an unregistered contractor to perform construction work.
/ lY
,-
PP Chi CANT H
, t ---
Signed and sworn to before me this
P ` o) * E ' . S � • day of . .De'C -tzv/ � , 20 i;2- .
0
...mow ^' t ' ,.*; , j d/L____ .W.lp, N �: A f3 L� G '. 4 , .
yam , � 'j +. , y0 , ' ¢ ` ?y �'
. F • ••,�,, . NOTARY PUBLIC in and for the State of Washington,
residing at g( #'t- County. „4,.,.,,,,,
67
Name as commissioned: 'x.47,- 2464 -/l,% -rte- ' `
At„,,,-;,$,
My commission expires: 5 --, /`I - 6'(U , : x
AFFCONT 1/13/00 2.1 .
■
r .
.'Mk' /. +v+.n r++,'.r. N.WwIrP•iCl'kM,. lIsA.M+71!!'1M1 N .#^M"pn>xn.xbnra ,1 >. -.. , .. .::i'+ +;fl: N';^ >,1+t2+S.r+upahi,r. P . ». .
•
■
ft
18.27.090 Exemptions. This chapter ,, :..all not apply to:
1. An authorized representative of the United States of the operation is made into contracts of amounts
Government, the State of Washington, or any less than $500 for the purpose of evasion of this
incorporated city, town, county, township, irrigation chapter or otherwise. The exemption prescribed in
district, reclamation district, or other municipal or this subsection does not apply to a person who
political corporation or subdivision of this state; advertises or puts out any sign or card or other
device which might indicate to the public that he is a
2. Officers of a court when they are acting within the contractor, or that he is qualified to engage in the
scope of their office; business of contractor; z
3. Public utilities operating under the regulations of the 10. Any construction or operation incidental to the ~ w
o:2
utilities and transportation commission in construction and repair of irrigation and drainage
construction, maintenance, or development work ditches of regularly constituted irrigation districts or o
incidental to their own business; reclamation districts; or to farming, dairying, co o
agriculture, viticulture, horticulture, or stock or poultry w =
4. Any construction, repair, or operation incidental to the raising; or to clearing or other work upon land in rural --1 F-
CO discovering or producing of petroleum or gas, or the districts for fire prevention purposes; except when p
drilling, testing, abandoning, or other operation of any any of the above work is performed by a registered 2
petroleum or gas well or any surface or underground contractor; 5
mine or mineral deposit when performed by an owner u - D
or lessee; 11. An owner who contracts for a project with a �d = w
registered contractor; F _
5. The sale or installation of any finished products, Z 1.-
materials, or articles of merchandise which are not 12. Any person working on his own property, whether I-- O
actually fabricated into and do not become a occupied by him or not, and any person working on 2 D
permanent fixed part of a structure; his residence, whether owned by him or not but this v o co
exemption shall not apply to any person otherwise 0
6. Any construction, alteration, improvement, or repair covered by this chapter who constructs an to
of personal property, except this chapter shall apply improvement on his own property with the intention 'z •
to all mobile /manufactured housing. A and for the purpose of selling the improved property;
mobile /manufactured home may be installed, set up, z
or repaired by the registered or legal owner, by a 13. Owners of commercial properties who use their own v co
contractor licensed under this chapter, or by a employees to do maintenance, repair, and alteration 0
mobile /manufactured home retail dealer or work in or upon their own properties; z
manufacturer licensed under chapter 46.70 RCW;
14. A licensed architect or civil or professional engineer
7. Any construction, alteration, improvement, or repair acting solely in his professional capacity, an
carried on within the limits and boundaries of any site electrician licensed under the laws of the state of
or reservation under the legal jurisdiction of the Washington, or a plumber licensed under the laws of
federal government; the state of Washington while operating within the
boundaries of such political subdivision. The
8. Any person who only furnished materials, supplies, or exemption provided in this subsection is applicable
equipment without fabricating them into, or only when the licensee is operating within the scope
consuming them in the performance of, the work of of his license;
the contractor; • .
15. Any person who engages in the herein , ;
9. Any work or operation on one undertaking or project regulated as an employee of a registered contractor ,;
by one or more contracts, the aggregate contract with wages as his sole compensation; 4 4 1 ,'t %r
price of which for labor and materials and all other - p highway P erations 16. Contractors on hwa , . ,
items is Tess than $500, such work, or operations hi J ro)'ec.ts. who have been �
,::.....„_,.,• ..;;
being considered as of a casual, minor, or pre qualified as required b • cha ,ter 13 of the Laws of `3r^
9 q q Y p , (: t,',.
inconsequential nature. The exemption prescribed in 1961, RCW 47.28.070 with the department of LIZ
this subsection does not apply in any instance transportation to perform highway construction, ... ` -v .-!..:
wherein the work or construction is only a part of a reconstruction, or maintenance work. +., , 1, 1 •11;
larger or major operation whether undertaken by the r ` f;
same or a different contractor, or in which a division cm i.2. ""
AFFCONT 1/13/00 = °:x "}` :'"'
,,.,. ^rh
e 5,,,,,, ..
,e,b4.„„,_,,
.. .} {rp VMWM!rn xh n.: F?X att?,*. 452W60,14` NWSX,+K+n
1 1 1
ROLL-UP
DOOR
DOOR
LL-UP
DOOR
VE- UP
RAMP
receptio
office
4 EN I)
M LI*
ro orn
office
cfice
spr.i nic
roorr.
31 u
IH
FUTURE CONSTRUCT I 3N
12"
15 ' -2
24 "
106"
15 ' -2 "
FUTURE CONSTRUCTION
PRESENT CONSTRUCTION
5 8 "
w
DCOR
FILE COPY
I underslind that tt:e Plan Chick approvals are
c?r.riprs and ornisons and approval of
p;,ins does i'ict authcrizo he violation of any
aticoted Receipt of con-
fractor's copy of approved plans acknowledged.
ri:PARATE. PERM!T
JIPED FOR:
CHAITCAL
ECTRICAL
ROLL-UP
DOOR
1
RECEIVED
CCTV OF TUKWILA
DEC 0 if 2002
PERMIT CENTER
102-.30
•
PALLET RACK ELEVATIONS
SCALE: 1/4"-1'-0°
COLUMN STRUT
(TYP)
AS NOTED
40 COLUMN
BRACKET ASSEMBLY
AS NOTED 1 TYP
jDAGONAL STRUT
COLUMN
j BEAMS
CANTILEVER RACK ELEVATIONS
SCALE: 1/4' =1' -O"
C ARMS
°HORIZONTAL STRUT
BRACKET ASSEMBLY
AS NOTED
0
O FOOT PLATE
2 3/4"
LOAD BEAMS 00
1/2"
® FLOOR ANCHOR DETAIL
SEE NOTES FOR SPECS
STRUCTURAL NOTES
1. MINIMUM YIELD (Fy) AND ULTIMATE (Fu) STEEL STRENGHTS SHALL BE AS FOLLOWS:
A) BEAMS AND COLUMNS Fy = 50k& Fu = 65 ksi
8) CANTILEVER RACK ARMS AND BASES Fy = 40ksi FU = 55ksi
C) BRACING STRUTS AND BASE PLATES Fy = 36 ksi Fu = 58 ksi
2. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE
A) PALLET RACK 38001bs PER LEVEL PER PAIR OF BEAMS.
B) CANTILEVER RACK 500Ibs PER ARM •
3. CONCRETE SLAB IS GIVEN AS 5" THICK WITH fc' = 2000psi
4. ALLOW. SOIL BEARING IS GIVEN AS 2,500 psf FOR GRAVITY LOADS.
5. TIE -DOWN ANCHORS SHALL BE HILTI KWIK BOLTS 1/2 "0 X 4 1/2" LONG
ANCHORS WITH 3" EMBEDMENT. USE AS FOLLOWS
A) PALLET RACK 2 ANCHORS PER BASE PLATE.
B) CANTILEVER RACK ONE ANCHOR AT EACH BASE END.
SPECIAL INSPECTION IS NOT REQUIRED
6. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA DEPICTING
THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS.
7. IF ANY DISCREPANCY OCCURS. CONTACT THE ENGINEER FOR CLARIFICATION.
DEC 0 4 2002
PERMIT CENTER
NU ER
SCZ
foundation plan special notes
easy up