Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D02-373 - MONEYTREE - TENANT IMPROVEMENT
MONEYTREE 6720 FORT DENT WAY #130 D02 -373 City of'rukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: DEVELOPMENT PERMIT Permit Number: D02 -373 Issue Date: 01/21/2003 Permit Expires On: 07/20/2003 Tenant: Name: MONEYTREE Address: 6720 FORT DENT WY, SUITE 130 Owner: Name: JOHN C RADOVICH LLC Address: 2000 124TH AVE NE #B 103, BELLEVUE WA Contact Person: Name: JENNIFER MUKAI Address: 355 110 AVE NE, SUITE 100 Contractor: Name: FOUSHEE AND ASSOCIATES Address: BOX 3767, BELLEVUE, WA Contractor License No: FOUSHAC158OD Phone: Phone: 425 - 641 -9200 Phone: 425 746 -1000 Expiration Date: 08/12/2003 DESCRIPTION OF WORK: COMMERCIAL TENANT IMPROVEMENT. EXISTING TRAINING ROOM MODIFIED TO OFFICE SPACE. STAGING AREA. ADDITION OF PARTITION WALL TO CREATE TWO NEW OFFICES. Value of Construction: $42,000.00 Fees Collected: $933.37 Type of Fire Protection: SPRINKLER Uniform Building Code Edition: 1997 Type of Construction: V N Occupancy per UBC: 0016 Public Works Activities: Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: Channelization / Striping: Start Time: Private: N Private: N ** Continued Next Page ** End Time: Public: N Public: N doc: Devperm N.1 D02 -373 Printed: 01 -21 -2003 .r..nm.rt. -aw iarc •e f.. nwn4n..,,,,I.,A40+,1411!W i -"F z ~w 6 0O N 0 to w J = Nu_ WO QQ LL Q. D =d 1— W Z= fr- O Z I— U D O N O F-- = v" H � O Z w U= O~ Z � City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: Date: 3 r � I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructions or the performance of work. I am authorized to sign and obtain this development permit. 124• f/ Signature: Print Name: ti4- Ag cj)g Ike) S Date: /--Z /--0) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: Devperm D02 -373 Printed: 01 -21 -2003 1 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Tenant: MONEYTREE PERMIT CONDITIONS Permit Number: D02 -373 Status: ISSUED Applied Date: 12/20/2002 Issue Date: 01/21/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All mechanical work shall be under separate permit issued by the City of Tukwila. 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 13: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 14: Maintain fire extinguisher coverage throughout. 15: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) 16: Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. 17: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard 10 -1) 18: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 19: * ** EXITS * ** - UFC Article 12 20: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 21: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 22: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 23: Manual operated edge- or surface - mounted flush bolts and surface bolts are prohibited. When exit doors are used in pairs and approved automatic flush bolts are used, the door leaf having the automatic flush bolts shall have no door doc: Conditions D02 -373 Printed: 01 -21 -2003 z w U0CO CO w J= F- (0 w0 u_? a =w z� o z w • w U0 o N O I- w• w irk u-O ..z O ~ z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 knob or surface - mounted hardware. The unlatching of any leaf shall not require more than one operation. (UFC 1207.3) 24: * ** SPRINKLER SYSTEMS * ** - UFC ARTICLE 10 - NFPA 13 25: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of wails, closets or partitions may require relocating and /or adding sprinkler heads. 26: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 27: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 28: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 29: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 30: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. 31: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 32: ** *ELECTRICAL * ** UFC Article 85 - NPFA 70 - NEC 33: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 34: * ** BUILDING CONSTRUCTION * ** - (UFC, UBC) 35: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of the Uniform Building Code. (UBC 804.1) 36: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 37: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: eI /4f >)-� -/ 4 Ai `A- bi , is Date: /— ? %— O doc: Conditions D02 -373 Printed: 01 -21 -2003 z = t~ w �QQ2 JU 00 CO Ca tu J= F- ai g J u_Q =d �W z= r`- F- O W W 2 U � O- O E- it,� F-0 tL O WZ • = 0 z OCT 28 '02 04:S3PM TUKI.TLA DCDiPW CITY OF TL Permit Center 6300 Souehcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. Project e l _� e' prr 01011- 1111-12/1)1<-11- _ _ .ey t.,/4-1v1.41 .1-; 'twee- , CiciAt -40-, 61- 1)(Y VeL Value of Construction: /.z Lco v, Site A dr (inclu Yuite. uvb 0 . City State/Zip: umb �r) Way $u4 -6 ) o T iik, �� Tax Parcel Number: Property Owner: ea4 DViCil I, MI Multi - family ❑ Warehouse ■ Hospital Phone:G4Z %' -16 JI , (eci,o Street Address:2nV00�:(( 4,j 1,46 46 iv •.y' ttty Sta a ip: Fax #: ,2 ii 5..7J/ g iito Contractor. f1ke:21,I°, x Phone: , -74l0 ' 1000 Street Address: �r, 1 d n� _ 5e J1Cv c '',^ -City Pt V jT 1'�/ Wr > l/L i _ Fax #: �& ' ..M t, , 13 -1 q Architect: Phone: Street Address 1�� M N � `Q1 Th� �t'� 1 A , r r 1ity ) dip: ✓ n ► L ti .1J1 t( t�K1W Fax #: 4 z (J ?1 S -/C0 — Engineer: Phone: Street Address: City State/Zip: Fax #: Contact Person: ra- 441vl 1�Vr iJ &VtVli.c • ',AA/ KM Phone: BLS (,��i ( i� — Street Address: may. no JL 1\)6 (5 VIr lob ftiteix CityNa 1 : Fax #: 4 r t•�1 c67701) Description of work to be done (please be specific): ei)Mati rUct,L clY V Irv.) now vy ti - 1-1-e'( -{b . 61 -hex 5.y:tt6 , -42t,t y 1 e C- Y4�,..k. 2 kyv 0 1-•h -u:G . 01011- 1111-12/1)1<-11- _ _ .ey t.,/4-1v1.41 .1-; 'twee- , CiciAt -40-, 61- 1)(Y VeL Existing use: ❑ Retail ❑ Restaurant ❑ ❑ Church ❑ Manufacturing ❑ ❑ SchooVCollege/University ❑ Multi - family ❑ Warehouse ❑Hospital Motel /Hotel Office Other Proposed use: ❑ Retail _ ❑ Restaurant 13 Church ❑ Manufacturing ❑ School/college/University MI Multi - family ❑ Warehouse ■ Hospital ❑ Motel/Hotel Office ❑ Other _ Building Square Feet: 3 q ,Z1' existing No. of Stories: Z Area of construction (sq ft): __7S - Will there be a change of use? 0 yes ❑ no If yes, extent of change: (Attach additional sheer If necessary) a. xl,�iti& .- '(�,tMtVl J noon fri tttpr1e et -40 0 -tra- ;2I L-r' �J S1-1, at i U (rYt /i 4')I cl/ l Iva u rrii„ Will there be rack storage? ❑yes no fire alarm ❑ none other (specify) �"' Existing fire protection features: sprinklers ❑ automatic Will there be storage of flammable/combustible hazardous material in the building? ❑ yes eve Attach list of materials and storage location on separate 8 1/2 X 71 paper indicating quantities & Material Safety Data Sheets IDate appllcation accepted: "' "APPLICA TRE� IES1 F 'R $L OR 'rl. � O, �P)` j:G� „ k15•. SiTFJCtyIC rPidhl; .REVlE1 't{/f,(FTf=1EEFOrL'd!,V!✓.1 "= fAd�tidnaJ'reKier+%s may he leiin1riei%Iiy; the .PuBliil:WOrk''Ellepartment).• . • - ❑ Channelization/Striping ❑ Curb cut/Access/Sidewalk ❑ Fire Loop/Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage lJ Street Use ❑ Water Main Extension r❑ Water Meter /Exempt #: Size(s): 0 Deduct CI Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation 0 Private 0 Public 0 Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and Is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review • Applications for which no permit is issued within 160 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application expires: (f% 2 G c Application taken by: tinitlals) PLEASE SIGN GACK OF APPLICATION FORM z W CQQ Lu JU 00 CD C3 WI F- U) tL WO J lL = W z�. I— o W ~ U0 CII- WW I LL. Z U= 0 1 - z �G1; ��� „n�2, ..� 04 f�54Pl�j .i;uKl;f I �-fa. ;1)C�il?W ry•''�K`; �' ;''I °,' -'.,: .tPPLIC.iT1 • ,M•:;`;ti i'4tit i 'y:', :•� ,•1 `; ' c °••t.•t .:..if i.:�•.:+ • • :'Pn3 %6; MUST BE SVB•IITTLD tt'ITf/ TH iLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER > ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITT D ❑ Complete Legal Description ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form F1-10). Four (4) sets of working drawings (five(5) sets for structural work), which include ❑ Site Plan (including existing fire hydrant location(s) ❑ 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). ❑ CV Floor plan: show location of tenant space with proposed use of each room labeled ❑ DOverall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. CL-Vicinity Map showing location of site Cl Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack.. Structural calculations are required for rack storage eight feet and over. ❑ - Indicate proposed construction of tenant space or addition and walls being demolished ❑ .' Construction details ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ 0 Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. 0 ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H-4, 'Affidavit in Lieu of Contractor Registration ": ?�r�ldii;;rrrp�ivrier`% ,wtfidir%z ':t1�' krill'fah e.aMzi•IJcanr'ls•oiher,tli n. the• arli riei,;: reglsCgied 'a,:enicect /en0lnper•, or.cont *e ton Jicerised,by.tfier•'Siat4 "'•: R��S7di.• Jn a j, t,firotal[tzed.'lecter.. rom the prripetty tiwner•46itioilzin :the• agent;:tti.submJt;chicpperrru appjication•khd.obtain•ch permit• wilt :be:rE77utrt;t :(s >'part o ):is'submit 1. ••"' i, . • ... , ••••• ,. • • : • • • . • • I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OP PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THiS PERMIT. Ht91L7JtNGTO,W R.:016AtJTHORIZEIYAGENT6 •• • .. .. . . Signature: `� I Date: l 2� ✓6 2. Print name: •��(� 22 Phone: I 4 ?�� -(�N� q�c�o Fax #: 42s -63 7- sZOa _ J Address �? .5 / )0ye. 1`/E SL �Q� City /State2ip � a a WA" ' 2 o / 11/!0/00 clpernd,.doc Z ~ W 6 UO to J I H W° 2 g _� I^ W Z= I— O ZI-- co a D U O — O H W • W • O WZ U= P. 0 Z 1 City of 'Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2954900455 Permit Number: D02 -373 Address: 6720 FORT DENT WY TUKW Status: PENDING Suite No: Applied Date: 12/20/2002 Applicant: MONEYTREE Issue Date: Receipt No.: R020001772 Payment Amount: 365.92 Initials: KAS Payment Date: 12/20/2002 02:01 PM User ID: 1684 Balance: $567.45 Payee: MONEYTREE TRANSACTION LIST: Amount Type Method Description Payment Check 59019 365.92 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 365.92 Total: 365.92 3571 12/20 97:10 TOTAL 365.92 doc: Receipt Printed: 12 -20 -2002 z 6 00 co 0 J N u_ WO} g u.Q co =a 2 z1._ O • ui Z I- � 0; U 0, O � O I- = W. - U Z 111 = O ~ Z City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z RECEIPT s, 1- z re W m QQ J U Parcel No.: 2954900455 Permit Number: D02-373 U O Address: 6720 FORT DENT WY TUKW Status: APPROVED co O Suite No: Applied Date: 12/20/2002 j _ Applicant: MONEYTREE Issue Date: t0 u WO Receipt No.: R03 -00063 Payment Amount: 567.45 g ¢. to D Initials: BLH Payment Date: 01/21/2003 11:08 AM = W User ID: ADMIN Balance: $0.00 i" Z ZI- F-- 0 Z I-- W uJ 'Dp UO -. TRANSACTION LIST: 01_,. Type Method Description Amount = III W F— Payment Check 203154 567.45 W Z LLI o H= O i'.- Payee: FOUSHEE ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 562.95 4.50 Total: 567.45 4607 01/23 ':77 16 TOTAL AL 12.(5 , 70 doc: Receipt Printed: 01 -21 -2003 Yr. M hvt 0.11 nwwrp' LAM'+`- ""•e^rn..e.two...r ∎. '--... •■ +r.r...�.. �..�..+....iM^. ww.+ r .,. +:�yyy�ro.vxm...�N^•••.w...:. .yww.. i.. en. w. ■•■■nrr,. .e■x•M•a.+r...7.. »MRNYfi0,Y0.41 Z INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • INSPECTION RECORD Retain a copy with permit (206)431 -3670 Project: MDN - .i/TRP_ e Type of uspection: fr1NAL_ A( -r7es O r PT me Date Called: a/03 Special Instructions: Date Wanted: 19 3 m� p.m. Requester: '� Kt' i 1H Phone k o? —eqt —7341 NApproved per applicable codes. Corrections required prior to approval. COMMENTS: r cVe t(Ne/A v w' ■ C 0 Inn p(-et-c. Cpl +o Fs„u� InspectorY--y5AU -R\olAti&9/-0- Date: 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: r `-s,�.:'. ?pd �"si ^�.�:'���i ���j - ,}'�:. �y�0.A�tu(T � cr���'��,1 h�/ S'.. ;� ^�'t;C ^� ".: {�i a:•f.: * ¢,'�;: �t.L ..:.�T.`1 .«•u1�C. h ^6ti�•rIIfii!w ' :�i'�SCwMAi�Sia"5'i�GlAaltCnlf� f�" i� .n.wx/,1o'k.aJnAC�tLM�.'A1M1'e:. ita kcrlf't .47,e Z Q • W 6U U O 0 W I t- N LL. O. 2 J LL j � W Z= Z F' W O • (1) O H WW I=- V • O WZ • Cr) oI- z INSPECTION NO. INSPECTION RECORD Retain a copy with permit 53 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ./L/Thne-- ( —Tr c C- Type of Inspection: • 1} lq 1 c. G'- DC��i( 1ri1 �l Address: (r" r: G fDer ---- ii-i wy Date Called' / -3- 03 Special Instructions: Date Wted: / ,� a.m. , / - I/ — ()j -p.m. t Request r: Phor_ o.` 9 LI 1.... Tit...4 LIApproved per applicable codes. ' Corrections required prior to approval. COMMENTS: • 1} lq 1 c. G'- DC��i( 1ri1 �l r I%i� 1%Yi(--1 / fiV. r-e v--. ro4rA C011, c\ar ctl Ue S O IJ- ckJ a t l 0 --#— 10 to -Ptroth/e.. 1CV) SP, 1 IAsulpd , rte, Al) G OO 0 4 - •P CI 5-4 ui A 1 KA, / 9-V. --Vel cA \ -4 ;I.e i 1r9 otbGve 2. clrea - .r °Mr\ li-v-.,°. (7, epreWrA $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: 'Itdi'St4d5' ' 1jauOar1...'01.4Pr. $4ra.,43W,44iK CY z ~W re 2 JU O 0 W_ 2 u W O gQ =• O F._W Z= WO W U� N 01 W - 2 F- H O LLJ Z • = O � z 0 02 - 373 • 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 Proj t: nto,o&-V 77,6E Type of Inspection: Address: (0 74:)67 ig,er Am-- ta Date Called: ,,,? -.75- - Special Instructions: y Date Wanted: —D Ca.m_y Reque§ter: --77-f/ Phoneil■fo:, ( ) 9 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Date: .2 Z6. 0 3 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ' ,410440,11,4. • < • I Z L• ij -J O 0 LLI 11.1 LL w 0 -J g u.. < w Do T: Z ‚-0 Z I- LL! uj 30 0 •co o — O f- ill I 0 I— :— IL 1,E5, cd 0 r- 0E" • 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Projpcit: /VI 0 ne 1)y-rep Typeof-Inspection: fr-ret mtne) Address. i 4070 My+ Del* IAJ Date Ca Iledi Special Instructions: Date Wad. c2+ 0.3 -157r117 Requester: Ke 111/-1 Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: •Freivv■I 0010 N.)-P 4, c.A\ \Di (ci( vAr Date: „;.. 0 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Art.ati.,k z 1.11 00 (J) u.) LLiI ju 0 g 111 Z I-0 Z ILJ uj C.) 0 c) w uj 1- LLJ I 0 LI (,) 0 0 • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: �- /`rGY1( /vC�� Type of gspection: !� (i r ' A191c1-7 res • � r� DeV►f w � rrNTS: `` PCl f NCa Date Cali — //- 3 Special Instructions: p rysi-- t---/tor. / Date Wanted: F. „2-472-03 Requester: fi—? Phone r7 c-- C4-- 7?c,71-/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: -) � rrNTS: `` PCl f NCa 0 TQ ) �t P(1 u I r r cf Ip.r) 2) TO\l % 1 rr t is v-, '1 i t S> Antvx■ se d 40 c 't 4_ . c;- 5 -0 -- ) --Q-e,r- c 1,NoiAc -pc 1 , -3•1 4)0i I \,oYac I n/ CA'l 9 sr-f or . Inspector e- Date: 1,2 01 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: z W re i 6 00 NO CO LLI J CO u- WO gQ F. W z= W° U0 ON c) =W WZ Uu, O~ z �,l r • ' 777%.17:17-; 4-7774`7■15:44k7T17,7077717,7,-Far47,17%.7.....,6, v•--rrrclitr t ; • - '7."1:77-7-7.771 City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM 'Project Name /1404 -C Permit No. ON - 3 7 3 ..' Address 22 0 For .,7 tii)Q Retain ,•k cur'rent—iraspection:schedul,p_ Needs shift inspection Suite #12)(-- 6/ Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: ..- , r'r ,, 6 / • . Attorized Signature FINALAPP.FRM ./ . Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 1.414412Wrg.teW=1.01,,Wowl,Ve.e,deeelhe.,..e.se... , • • e see ,e-s-rv,ere 1...ena."1,the.let•VerNieleVmeee•te_. z 1• 1- z u.i 0 O 0 coo w w WI co u_ w 0 5 (i) a iu z ▪ o z 1- w w 0 0- O 1- W tu u. o Lij z o o z City of Tukwila Steven M. Mullet, Mayor August 13, 2003 Department of Community Development Steve Lancaster, Director Jennifer Mukai 355 110th Avenue NE #100 Bellevue, WA 98004 RE: Permit Application No. D02 -373 6720 Fort Denty Way Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to September 17, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, C(.ii .w GLr Stefania Spencer Permit Technician Ir' Xc: Permit File No. D02 -373 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 artawAVat apA$VrAiVbae+xtorAS�xn, z w re 2 JU 00 W= H SQ u- WO 2 u_¢ =a 1- W z= 1- O Z 1— 1.1.1 W U� 0 Y o1- W ui HI- LL O. WZ = O~ z • Dave Grage - 6720 Fort dent Way r..10.-373 From: From: To: Date: Subject: Joanna Spencer Dave Grage; Han Kirkland 2/5/03 5:02PM 6720 Fort dent Way D02 -373 Are their backflows ok ? CC: Joanna Spencer not currently compliant with state law ,.try PROJECT NAME: MtN 7fe lr PERMIT` 'O:. ► r - 373 Site Address: 6720 Fc -r .D I Y W Original Issue Date: REVISION LOG Revision I Date Staff No. 1 Received Initials Date Issued • Staff Initials 1 I 2-q-03 $KS Summary of Revision: N6-0 Slz)2,464- Roden enoarriarz, A.dp 0-/W -N2b b 'fo A•.vrciel ex c/ , /l%u) Dooms SAS ?cf �l�v� s' =2Drr� D�°E� � /cam i9 Received By: !-F,' 2 41 (please print) i Revision No. 1 Date Received ! I Staff Initials Date Issued Start Initials I f Received By: Summary of Revision: Received By: • (please print) Revision No. • Date Received Staff Initials Date Issued Staff Initials a Summary of Revision: Received By: Received By: (please print) Revision No. Date Received Staff Initials Date Issued Staff Initials 1 Summary of Revision: , Received By: Received By: please prin Revision No. Date Received Staff Initials Date Stan Issued Initials I ! Summary of Revision: Received By: ease t)nn z w JU 00 w J = w° 2 LLa d Z= I— 0 Z F— U0 0— 0H wW wZ 0 z • PERMIT COORD OPY PLAN REVIEW /ROU NG SLIP ACTIVITY NUMBER: D02 -373 DATE: 02 -05 -03 PROJECT NAME: MONEYTREE SITE ADDRESS: 6720 FORT DENT WY - SUITE 130 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Is Issued DEPA TMENT : Buil•ing Division Pub1cl�Works n �1w IW J It1h 2- G'-°3 Fire Prevention Structural 01PL, iLGA. Z.- to 173 Planning Division ❑ Permit Coordinator! DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [yr Comments: Incomplete DUE DATE: 02 -06-03 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route [1 Structural Review Required p No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03 -06-03 Not Approved (attach comments) r DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW,, Staff Initials: PERMIT COORD COPY Documents/routing slip.doc 2.28 -02 z w QQ• � JU O 0 J• = CO LL W0 2 u_? Nd = z�. I— 0 zI- w • w 0 0 Ca O - O I- wW 1-F 9--o W.. —▪ I O ~ z PLAN REVIEW /ROUTING SH P ACTIVITY NUMBER: D02 -373 PROJECT NAME: Moneytree DATE: 12 -20 -02 SITE ADDRESS: 6720 Fort Dent Way, Ste 130 XOriginal Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: 'Z_2(p- Building Division 141 Pub!sZ� -oZ Structural 12-21p-D2- Fire Prevention 5;1 6p, L'/ J 2 -240 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12- 24-02 Complete Comments: Incomplete ❑ Not Applicable U Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 1-21 -03 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2.28.02 w: r �CiSd�GSt:7A�i PERMIT COORD COPY S.6 19 . ,.. �, �,..• r. �w. r. °�r,,�s „ +a�anF�d7:r.!Y7Yr1'�' z w 00 fn J = I— w0 2 g< =W z1._ zI w • w UO O N O I- w 111 I 0 ..Z w = O F- Z "4,.�r y ob *y r: ii City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431-3670 '. 1:.' r.:i? �.` �a !. ".:+'.',;;�'x' >ka'.,c.t:�. fr'?:. sr: �"-.'^"l: vi; al} �t3:: �i3 'F•J�1+,4!:al!: {.�,�r,yr.�.i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: *05 Plan Check/Permit Number: DO Z - 37" ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # r' Revision # 1 after Permit is Issued Project Name: VUYlty'h'ZC, Project Address: (OW 'il✓ -fr tkv t' WaA/ ,51/Lku i "70 Contact Person: Nievl Wk{ /JP( frth(k4 - Phone Number: +PS ' -`qz Summary of Revision: j•!ttN 6f1)►44y, rVDfrt has -1 YYl,24i lev( Ql2G( Po (ake.a .-t C 114 tAi o.-6cu. mttac v into 12.6Lkl -h) P.V From opal 0• -4166 q/VcA (& CE_IV,1t �ITY OF Ti Wm /IL • 11•J Sheet Number(s): 1A -77, 1 Ilk • (4.( i I P Ail "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: [IT Entered in Sierra on Zy�3 i �• 1tMN/04161.V lN•InwtipHrMH'r.YNWiI YA��t +�at!�•!�r %�Cmi+.Ya•e+m 08/30/00 z w ce JU 00 u) o 1 w 0 g u_¢ =• d w Z= H ZI- w • w U 0 O — O H w w LI z w — co 0 '` •z NUV -26 -2002 14 08 FOUSHEE to 4257463737 P.02/02 • CITY RECEIVED UEU 2 01UO2 PERMIT CENTER LEGAL DESCRIPTION PARCEL B: THAT PORTION OF VACATED TRACTS 4 THROUGH 9 AND 12 THROUGH 17, AND VACATED STREETS ADJOINING IN GUNDAKER AND INTERURBAN ADDITION, LYING WITHIN SECTIONS 23 AND 24, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M. DESCRIBED AS FOLLOWS: BEGINNING AT HIGHWAY ENGINEER'S STATION P.O.T. (2M) 127 +45.0 ON THE 2M LINE SHOWN ON THE STATE HIGHWAY MAP OF PRIMARY STATE HIGHWAY #1 (SR405) GREEN RIVER INTERCHANGE, SHEET 2 OF 4 SHEETS, ESTABLISHED BY COMMISION RESOLUTION #1192, FEBRUARY 19, 1962, THENCE NORTHEASTERLY AT RIGHT ANGLES TO SAID 2M LINE NORTH 30'27'06" EAST 218.36 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 140 FEET (MEASURED AT RIGHT ANGLES) NORTHEASTERLY OF THE SOUTHWESTERLY MARGIN OF VACATED KENNEDY STREET (6TH PLACE S.) AS SHOWN ON THE PLAT OF GUNDAKER'S INTERURBAN ADDITION TO SEATTLE, AS PER PLAT RECORDED IN VOLUME 14 OF PLATS, PAGE 46, RECORDS OF KING COUNTY, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL TO BE DESCRIBED HEREIN, THENCE FROM SAID TRUE POINT OF BEGINNING ALONG SAID PARALLEL LINE NORTH 59'32'54" WEST TO THE BANK OF THE GREEN RIVER, THENCE ALONG THE BANK OF THE GREEN RIVER THE FOLLOWING COURSES: NORTH 38'19'12" EAST TO A POINT LYING SOUTH 30'04'58" WEST 334.53 FEET FROM THE SOUTHWESTERLY LINE OF THE LANDS CONVEYED TO KING COUNTY BY STATUTORY WARRANTY DEED RECORDED UNDER RECORDING tl NO. 7507300471 AND NORTH 30'04'58" EAST 334.53 FEET TO SAID SOUTHWESTERLY LINE, THENCE ALONG SAID SOUTHWESTERLY LINE SOUTH 59'24'45" EAST 183.62 FEET TO A POINT ON THE NORTHWESTERLY LINE OF THE LANDS CONVEYED TO THE CITY OF TUKWILA BY QUIT CLAIM DEED RECORDED UNDER RECORDING NO. 0 7410290105, THENCE ALONG LAST SAID NORTHWESTERLY LINE THE FOLLOWING COURSES: 'le FROM A TANGENT THAT BEARS SOUTH 30'53'45" WEST ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 60.00 FEET AND A CENTRAL ANGLE OF 24'24'42 ", AN ARC LENGTH OF 13.63 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 22'08'00" WEST 223.43 FEET, THENCE TANGENT TO THE PRECEDING (A CURVE SOUTH 30'27'06" WEST 66.52 FEET TO THE TRUE POINT OF BEGINNING, -,o n m c =i EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. X70 41114 7708040599, SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. 1 N o0 (A) APN #295490 -0455 -I c gl- > M N z ~• W 6U U O J 1- U) LL LL O u =• a Z 1-O z�- LLI • 0 O • N O H =w 0 LI- O ..z U P- i- 0 z CONSTRUCTION LEGEND GRID HEIGHT NON - COMBUSTIBLE PARTITION WALL GRID HEIGHT NON - COMBUSTIBLE PARTITION WALL WITH ACOUSTICAL NON - FACED BAT' INSULATION EXISTING WALL TO REMAIN B/S FULL T. REL'TE: TEMPERED GLASS SYMBOLS LEGEND 112051 ROOM NUMBER REFERENCE DOOR TYPE /HARDWARE CONVENTION: ROOM NUMBER DOOR TYPE HARDWARE TYPE 1205 - ELEVATION POINT DETAIL REFERENCE BUBBLE WALL SECTION REFERENCE BUBBLE AREVISION REFERENCE 10 INTERIOR ELEVATION SYMBOL REFERENCE KEY (REFER TO KEY NOTES) BREAKLINE SYMBOL WALL FINISH REFERENCE KEY (REFER TO FINISH SCHEDULE) FLOOR FINISH REFERENCE KEY (REFER TO FINISH SCHEDULE) B1 BASE REFERENCE KEY (REFER TO FINISH SCHEDULE) F.E.C. NORTH REFERENCE B/S SEMI - RECESSED WALL MOUNTED FIRE EXTINGUISHER 11_0 CARDREADER LOCATION (COOR. WITH ELECTRICAL DWGS.) VICINITY MAP SCALE: NTS "Aerstard L`i:.i ::' ` = % C: eck app cvaiS ace :. b ect to errors and orriSS;. a and apprOVat cf plans does not authorize the vio;ation of any adopted code or ordinance. Receipt of c:wn- Tractor's copy of approved plans acknowledged. NORTH By Date C Permit No • R A, 2) NO C�;,°,; : z S ,-L BE MACS TO SZC7E , : < wiTHCUT PR:Z R : 7O;Vf L OF BUILDING DIVISION WP-L REWRE A NEW PLAN SUBMITTAL . - ,TOMAL RAN REVWW F"FL a LEGAL DESCRIPTION PARCEL B: THAT PORTION OF VACATED TRACTS 4 THROUGH 9 AND 12 THROUGH 17, AND VACATED STREETS ADJOINING IN GUNDAKER AND INTERURBAN ADDITION, LYING WITHIN SECTIONS 23 AND 24, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M. DESCRIBED AS FOLLOWS: BEGINNING AT HIGHWAY ENGINEER'S STATION P.O.T. (2M) 127 +45.0 ON THE 2M LINE SHOWN ON THE STATE I-1IGHWAY MAP OF PRIMARY STATE HIGHWAY #1 (SR405) GREEN RIVER INTERCHANGE, SHEET 2 OF 4 SHEETS, ESTABLISHED BY COMMISION RESOLUTION #1192, FEBRUARY 19, 1962, THENCE NORTHEASTERLY AT RIGHT ANGLES TO SAID 2M LINE NORTH 30'27'06" EAST 218.36 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 140 FEET (MEASURED AT RIGHT ANGLES) NORTHEASTERLY OF THE SOUTHWESTERLY MARGIN OF VACATED KENNEDY STREET (6TH PLACE S.) AS SHOWN ON THE PLAT OF GUNDAKER'S INTERURBAN ADDITION TO SEATTLE, AS PER PLAT RECORDED IN VOLUME 14 OF PLATS, PAGE 46, RECORDS OF KING COUNTY, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL TO BE DESCRIBED HEREIN, THENCE FROM SAID TRUE POINT OF BEGINNING ALONG SAID PARALLEL LINE NORTH 59'32'54" WEST TO THE BANK OF THE GREEN RIVER, THENCE ALONG THE BANK OF THE GREEN RIVER THE FOLLOWING COURSES: NORTH 38'19'12" EAST TO A POINT LYING SOUTH 30'04'58" WEST 334.53 FEET FROM THE SOUTHWESTERLY LINE OF THE LANDS CONVEYED TO KING COUNTY BY STATUTORY WARRANTY DEED RECORDED UNDER RECORDING NO. 7507300471 AND NORTH 30'04'58" EAST 334.53 FEET TO SAID SOUTHWESTERLY LINE, THENCE ALONG SAID SOUTHWESTERLY LINE SOUTH 59'24'45" EAST 183.62 FEET TO A POINT ON THE NORTHWESTERLY LINE OF THE LANDS CONVEYED TO THE CITY OF TUKWILA BY QUIT CLAIM DEED RECORDED UNDER RECORDING NO. 7410290105, THENCE ALONG LAST SAID NORTHWESTERLY LINE THE FOLLOWING COURSES: FROM A TANGENT THAT BEARS SOUTH 30'53'45" WEST ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 60.00 FEET AND A CENTRAL ANGLE OF 24'24'42 ", AN ARC LENGTH OF 13.63 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 22'08 °00" WEST 223.43 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 30'27'06" WEST 66.52 FEET TO THE TRUE POINT OF BEGINNING, EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. 7708040599, SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. APN #295490 -0455 ABBREVIATIONS or 0 A/C ACOUS. AC.T. ADD. ADJ. ADJUS. A.F.F. ALT. APPROX. ARCH. 8D. BET. BLDG. IBLK. BLKG. BOT. B/S CAB. CER. CHAMF. CIRC. CLG. CLR. CNTR. COL. CONC. CONST. CONT. AT CENTERLINE NUMBER SQUARE FEET iDEGREE(S) AIR CONDITIONING ACOUSTICAL ACOUSTIC TILE ADDENDUM ADJACENT ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE APPROXIMATE ARCHITECT BOARD BETWEEN BUILDING BLOCK BLOCKING BOTTOM BUILDING STANDARD CABINET CERAMIC CHAMFER CIRCLE CEILING CLEARANCE) COUNTER COLUMN CONCRETE CONSTRUCTION CONTINUOUS CONTR. CONTRACTOR CORR. CORRIDOR CPT. CARPET C.T. CERAMIC TILE 1CTR. CENTER DEMO. DET. D.F. DIAM. DIM. DN. DR. DWG. DWR. E. EA. EL. ELEC. ELEV. ENCL. EQ. EQUIP. EST. EXH. EXIST. EXP. EXT. F.E. F.E.C. DEMOLITION DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DOWN DOOR DRAWING DRAWER EAST EACH ELEVATION ELECTRICAL ELEVATOR ENCLOSE(URE) EQUAL EQUIPMENT ESTIMATE EXHAUST EXISTING EXPANSION EXTERIOR FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET F.F. F.H. FIN. FLR. FLUOR. F.O.S. F.O.C. F.O.F. FT. FURR. FUT. GA. G.B. G.C. GEN. GL. G.W.B. GYP. H.C. HD. HDCP. ;HDR. HDWR. H.M. HORIZ. FACTORY FINISH FULL HEIGHT FINISH(ED) FLOOR FLUORESCENT FACE OF STUD(S) FACE OF CONCRETE FACE OF FINISH FOOT /FEET FURRED /FURRING FUTURE GAUGE GRAB BAR GENERAL CONTRACTOR GENERAL GLASS /GLAZING GYPSUM WALL BOARD GYPSUM HOLLOW CORE HEAD HANDICAPPED HEADER HARDWARE HOLLOW METAL HORIZONTAL HR. HOUR HT. HEIGHT H.V.A.C. HEATING VENTILATING AIR CONDITIONING INSUL. INT. JAN. JT. KIT. KPL. LAM. A L.H. L. L.L. T.E. LT. LVR. MAX. M.C. MECH. MEMB. MET. MEZZ. MFR. MIN. MISC. MTD. MULL. N. N.F.S. N.I.C. NO. NOM. N.T.S. INSULATION INTERIOR JANITOR JOINT KITCHEN KICKPLATE LAMINATE(D) LAVITORY LEFT HAND LENGTH /LONG BY LANDLORD AT TENANT'S EXPENSE LIGHT LOUVER MAXIMUM MEDICINE CABINET MECHANICAL MEMBRANE METAL MEZZANINE MANUFACTURE(R) MINIMUM MISCELLANEOUS MOUNTED MULLION NORTH NON FROST SUSCEPTIBLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE O.A. O.C. O.D. OH. OPP.H. OPNG. OPP. P.B. P.BD. P -LAM PLWD. PNL. PR. PTN. OVERALL ON CENTER OUTSIDE DIAMETER OVERHEAD OPPOSITE HAND OPENING OPPOSITE PANIC BAR PARTICLE BOARD PLASTIC LAMINATE PLYWOOD PANEL PAIR PARTITION Q.T. QUARRY TILE PAD. RADIUS R.B. RESILIENT BASE R.D. ROOF DRAIN R.T. RESILIENT TILE REF. REFERENCE REFL. REFLECTED REFR. REFRIGERATOR REG. REGISTER REINF. REINFORCING REQ. REQUIRED REV. REVISION R.H. RIGHT HAND RM. ROOM R.O. ROUGH OPENING S. SOUTH S.C. SOLID CORE S.C.D. SEAT COVER DISPENSER SCH. SCHEDULE SEAL. SEALANT SH. SHELF SECT. SECTION SHT. SHEET SIM. SIMILAR S.L.M. SPECIAL LAMINATED EDGE SPEC. SPECIFICATION SQ. SQUARE S.STL. STAINLESS STEEL STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURAL SUSP. SUSPENDED T.B. TOWEL BAR T.C. TERRA COTTA TEL. TELEPHONE TEMP. TEMPERED TERR. TERRAllO THK. THICK(NESS) THRESH. THRESHOLD TKBD. TACKBOARD T.V. TELEVISION TYP. TYPICAL UNFIN. UNFINISHED U.N.O. UNLESS NOTED OTHERWISE VCT VINYL COMP. TILE VEN. VENEER VERT. VERTICAL VEST. VESTIBULE VFY. VERIFY V.W.C. VINYL WALL COVERING W. WEST /WIDE W/ W W WOOD W/O WITHOUT �H►►�T WEIGHT WSCT. WAINSCOT GENERAL NOTES 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL APPUCABLE SAFETY CODES. 2. THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER /ARCHITECT /ENGINEER HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR. HIS AGENTS, EMPLOYEES, OR SUBCONTRACTORS. 3. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT HIS OWN EXPENSE. 4. SPRINKLER. PLUMBING, MECHANICAL, AND ELECTRICAL ARE UNDER SEPARATE PERMIT. 5. CODES: ALL WORK SHALL CONFORM TO THE APPUCABLE BUILDING CODES AND ORDINANCES_ IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. 6. STRUCTURAL, PLUMBING, MECHANICAL. ELECTRICAL AND FIRE PROTECTION DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE BUILDING OWNER, TENANT, OR ARCHITECT. 7. USE G.W.B. METAL TRIM AT ALL CORNERS AND EDGES, PAINT TO MATCH ADJACENT WALL 8. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING SPACE CLEAN, WASH ALL WINDOWS AND GLASS, POLISH ALL HARDWARE. REPLACE AND PATCH AREAS OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. 9. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY PERMITS do FEES, EXCEPT THE BUILDING PERMIT SUBMITTAL FEE WHICH WILL BE PROVIDED BY THE TENANT. DIMENSIONS 1. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. 2. DO NOT SCALE DRAWINGS: THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF DISCREPANCIES ARE FOUND. 3. COORDINATION: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS. 4. CONSTRUCT WALLS PLUMB AND SQUARE W/ EXISTING STRUCTURE AND NEW CONSTRUCTION UNLESS NOTED OTHERWISE. FIRE PROTECTION 1. IF NECESSARY, PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RATED ELEMENTS AS REQUIRED BY CODE. CONSTRUCTION 1. COORDINATE CONSTRUCTION SCHEDULING WITH BUILDING REPRESENTATIVE AND ARCHITECT TO ALLOW ONGOING OPERATION OF THE FACILITY DURING CONSTRUCTION. 2. CONTRACTOR SHALL INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO BEGINNING THE WORK. 3, CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FIRE TREATED BLOCKING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 4. ALL NEW CONSTRUCTION SHALL BE STABILIZED AGAINST LATERAL MOVEMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE UNIFORM BUILDING CODE. MAX. DISTANCE ACCEPTABLE BRACES SHALL BE 8' -0 ". 5. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS NOTED AS EXPOSED ON CONSTRUCTION DRAWINGS. 6. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. CEILING 1. CEILING HEIGHTS, WHERE INDICATED, ARE FROM FINISHED FLOOR ELEVATION TO BOTTOM OF CEILING GRID OR OTHER FINISH SURFACE. 2. SUPPORT DATA - LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEG. APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEG. FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. SEE DETAIL 12/IA -9.1. 3. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER CHAPTER 47.1812 OF THE UBC STANDARDS. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER CHAPTER 47.1812 OF THE UBC STANDARDS. DISCONTINUOUS ENDS OF CROSS- RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. 4. CONTRACTOR SHALL INSTALL CEILING TILES ONLY AFTER ALL CABLING AND CEILING PLENUM EQUIPMENT /DUCTWORK HAS BEEN INSTALLED. FINISHES 1. ALL PAINT AND OTHER APPLIED FINISH ITEMS SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 2. CARPET CONTRACTOR SHALL FURNISH AND INSTALL RUBBER REDUCER STRIPS AT LOCATIONS WHERE CARPET AND VINYL COMPOSITION TILES MEET. 3. FLOOR COVERING IN CLOSETS SHALL BE THE SAME AS THAT OF THE SPACE UNTO WHICH THE CLOSET DOOR OPENS, U.N.O. 4. PREPARE FLOOR PER FLOORING AND CARPET MANUFACTURER'S RECOMMENDATIONS TO PROVIDE LEVEL AREA FOR FLOORING INSTALLATION AND LEVEL FLOORING TRANSITIONS. 5. CONTRACTOR TO SUBMIT FULL CARPET SEAMING PLAN AND INSTALLATION METHOD TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. PLUMBING, MECHANICAL & ELECTRICAL 1. PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGS TO BE SUBMITTED UNDER SEPARATE PERMIT. DRAWING INDEX IA -0.0 GENERAL NOTES IA -1.1 SITE PLAN IA -3.1 DEMO /FLOOR PLAN, RCP IA -6.1 FINISH PLAN IA-9.1 DOOR SCHEDULE/ WALL /SECTION DETAILS CITY O ?:.,FM∎i_A FEB 2 1 2D3 CODE INFORMATION CONSTRUCTION TYPE: 5 -N OCCUPANCY: B BUILDING IS SPRINKLERED APPLICABLE EDITIONS OF BUILDING CODES: REG. FOR BARRIER FREE DESIGN. 1997 UNIFORM BUILDING CODE 4th EDITION OF THE WASHINGTON STATE AREA: BUILDING AREA: 39,274 SF TENANT IMPROVEMENT: 2,075 SF PROJECT TEAM OWNER J.C. RADOVICH 2000 124TH AVE. NE., B103 BELLEVUE, WA 98005 VOICE: (425) 454 -6060 FAX: (425) 453 -9740 CONTACT PERSON: REBECCA DAVIDSON BUILDING TENANT MONEYTREE, INC. 6720 FORT DENT WAY, #230 SEATTLE, WA 98188 CONTACT: JENNIFER MAIETTA VOICE: (206) 246 -3500 EMAIL: Jennifer .Maietta©moneytreeinc.com ARCHITECT JPC ARCHITECTS 355 110TH AVE NE SUITE 100 BELLEVUE, WA 98005 VOICE: 425- 641 -9200 FAX 425 -- 637 -8200 CONTACT PERSONS: ANN DERR EMAIL: Arnd @jpcarchitects.com GENERAL CONTRACTOR FOUSHEE 3260 118TH AVE SE BELLEVUE, WA 98005 VOICE: 425- 746 -1000 FAX 425 - 746 -3737 CONTACT PERSON: DAVE TRULSON EMAIL: Dtrulson @foushee.com ELECTRICAL CONTRACTOR TBD. MECHANICAL CONTRACTOR TBD. r:1':io 1 JPC ARCHITECTS ass noh Ane PE - .suite 100 Bellevue, WA 98004 tel 1425; 641 -9200, fax {4251637 -8200 M ON EYTREE 6720 FORT DENT WAY #130 FORT DENT OFFICE BUILDING TUKWILA, WASHINGTON Design Team JPC JD,JM DON JPC Rope Nei AD 12 -16 -02 02 -100 -0646 Revisions Na or. Deration '2-20-02 PERMIT SUBMITTAL 01-17-03 CONSTRUCTION ISSUE -31 -03 PERMIT REVISION Registration 6485 REGISTERED ARCHITECT STA-TE OF ,.A Keyplan RECEIVED CITY OF TUKWILA FEB 0 4 2003 PERMIT CENTER Sheet Title GENERAL NOTES Sheet No. IA -0.0 © 2002, JPC Mcfasces, PLIC r1 1:3440-(1-em 1tv$1I&PSA) iZEQu tb - •F• lb IF�iI.4L . CUIPA 2,12•/03 1 1 • °1 iNCi4 .• •.i • tz0 SITE PLAN Scale: 1/16"=1'-0" SCOPE OF WORK -FIRST FLOOR: 2,075 SQFT -NO STRUCTUAL CHANGES -CHANGE OF USE EXISTING TRAINING ROOM COVERTED TO OFFICE SPACE AND STAGING/STORAGE AREA 1 Cede PAWNS 1 PARKIN* vac peRT WA'( 1 1 • JPC ARCHITECTS 356 t1Dth Pose NE -,Suite 100 Bellevue, WA 98004 tel 14251641-9200, fax 44251637-8200 ■ MONEYTREE 6720 FORT DENT WAY #130 FORT DENT OFFICE BUILDING TUKWILA, WASHINGTON Design Team J PC Row Checked JD,JM AD Deo 11PC Pmject No. 12-16-02 C2-100-0646 Revisions No Os analplon 12-20-02 PERMIT SUBMITTAL 31 01-17-03 CONSTRUCTION ISSUE 01-31-03 PERMIT REVISION Registration F4R5 !STED DERR STATE OF Keyplan c4smai, FEB 0 4 2003 RE RN, c;ENTE Sheet Title SITE PLAN Sheet No. IA-1.1 4 MM. SCOPE OF - — - WORK , FLOOR NOTES 1. INFORMATION SHOWN ON THE DRAWINGS RELATNE TO EXISTING CONDITIONS ARE GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT THE GUARANTIES OF ACCURACY; FIELD VERIFY ALL EXISTING CONDITIONS. 2. MAINTAIN A CLEAR AND UNOBSTRUCTED PATH TO EXITS AT ALL TIMES. 3. PROVIDE FIRE TREATED WOOD BLOCKING OR EQUIVALENT SHEET METAL AT ALL MILLWORK. 4_ PROVIDE FIRE RATED GROUTING OR SAFING AT ALL FLOOR PENETRATIONS AS REQUIRED. COORDINATE WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DOCUMENTS- 5. PROVIDE SEISMIC WALL BRACING AT ALL UNSUPPORTED (NON-LOADED) INTERIOR PARTITIONS OVER 8' -0" IN LENGTH. PER DETAIL 1 /IA -9.1. 6. PROVIDE SEISMIC WALL BRACING AT ALL WALLS, SUPPORTING SHELVES, WALL CABINETS OR WALL MOUNTED ITEMS. 7. REFER TO ORIGINAL SHELL AND CORE DOCUMENTS FOR INFORMATION REGARDING FURRING OF STRUCTURAL SUPPORT COLUMNS AT BUILDING INTERIOR AND PERIMETER - 8. ITEMS NOTED BY "D" ARE TO BE REMOVED. ITEMS NOTED BY "N" ARE NEW. rTEMS NOTED BY "R" ARE RELOCATED. ITEMS WITHOUT NOTATION ARE EXISTING. 9. DOORS WITHOUT AN IDENTIFICATION NUMBER ARE EXISTING WITHOUT MODIFICATION U.N.O. 10. FURNITURE OUTLINES PROVIDED FOR INFORMATION ONLY FURNITURE TO BE SUPPLIED BY OTHERS. DEMO NOTES 1 • COMPLY WITH ALL RULES AND REGULATIONS OF GOVERNMENTAL AUTHORITIES HAVING JURISDICTION OVER DEMOLITION WORK. 2. DEMOLITION INCLUDES COMPLETE REMOVAL AND DISPOSAL OF DEMOLISHED ITEMS. RETAIN SALVAGEABLE ITEMS WHERE OR WHENEVER APPROPRIATE. COORDINATE STORAGE WITH OWNER OR REUSE CN PROJECT. 3. NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS BETWEEN EXISTING WORK. AND NEW CONSTRUCTION PRIOR TO PROCEEDING WITH THE 4. REMOVE, REPLACE AND RELOCATE EXISTING MECHANICAL, ELECTRICAL AND FIRE PROTECTION EQUIPMENT /DEVICES AS REQUIRED FOR NEW CONSTRUCTION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, PULL OUT WIRING BACK TO PANEL. SEE DESIGN BUILD MECHANICAL, ELECTRICAL AND COMMUNICATIONS DRAWINGS FOR ADDITIONAL INFORMATION. 5. PROTEr.T STRUCTURAL ELEMENTS FROM DAMAGE DURING CONSTRUCTION. 6. PRIOR TO START CF WORK, COORDINATE WITH TENANT THE SCHEDULE FOR SHUTOFF, CAPPING AND /OR CONTINUATION OF UTILITY SERVICES REQUIRED. 7. EXISTING DOORS, FRAMES AND HARDWARE SCHEDULED TO BE REMOVED SHALL BE SALVAGED AND RELOCATED TO OWNER STORAGE OR REUSE WHERE OR WHENEVER APPROPRIATE. 8. PATCH AND REPAIR EXISTING WALLS AT DEMOLISHED AREAS TO A "LIKE -NEW" APPEARANCE. RCP NOTES SCOPE — OF WORK SCOPE — ---\\ OF WORK J�'C ARCHITECTS EXISTING OFFICE i EXISTING A CONFERENCE EXISTING OFFICE EXISTING OFFICE �/35b 110th Ave NE - S�ata 1100 Bellevue, WA 99004 . tel [t251bat -9200, fax 442516374200 M O N E Y T R E E 6720 FORT DENT WAY #130 FORT DENT E OFFICE BUILDING A KWIC WASHINGT TUKWILA, WASHINGTON Design Team ENTRY EXISTING SERVER [ 115 [ OFFICE OPEN WORK' STAGING .11.0 ProNct No. 02- 100 -0646 _ i KITCHEN Revisions LESS THAN 60% OF THE LIGHTING IS NET:'. INSTALLED LIGHTING WATTAGE HAS BEEN INCREASED BY 64 WATTS. 4 i a.e o� , ' 2 -20 -02 PERMIT SUBMITTAL 1 01 -' 7 -03 CONSTRUCTION ISSUE L 01-31-03 PERMIT REVISION Registration 6485 REGISTERED 1. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS ARE GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT THE GUARANTIES OF ACCURACY, THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. 2. REFER TO SHELL AND CORE DRAWINGS FOR STAIR AND CORE ROOM INFORMATION. 3• MECHANICAL, ELECTRICAL AND LIFE SAFETY ARE SHOWN BASED ON INFORMATION PROVIDED BY OTHERS AND IS TO BE USED FOR COORDINATION PURPOSES ONLY. 4. PROVIDE FIRE RATED GROUTING OR SAFING AT ALL CEILING PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING REQUIREMENTS. COORDINATE WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DOCUMENTS. 5 COONT A CIRYT TO N ALL WANCE, FOR ADDITIONAL CEILING EXIT SIGNS 6. AS REQUIRED ALL SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH UBC 713.10 AND ALL FIRE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH UBC 713.11. 7. EXIT ILLUMINATION LIGHTS WILL HAVE EMERGENCY BACK -UP POWER PER 1997 UBC. 8• ITEMS NOTED BY "D" ARE TO BE REMOVED. ITEMS NOTED BY "N" ARE NEW. ITEMS NOTED BY "R" ARE RELOCATED. ITEMS WITHOUT NOTATION ARE EXISTING. 9. REBALANCE EXISTING HVAC TO MEET NEW ARCHITECTUAL LAYOUT. Keyplan RECEIVED crTY OF *uKwILa FEB 0 4 2003 PERMIT CENTER Sheet Title FLOOR PLAN P Sheet No. RCP /DEMO RCP - 1ST FLOOR FLOOR /DEMO PLAN - 1ST FLOOR Scale: 1/8 " =1' —O" , Scale: 1/8 " =1' -0" RCP KEY NOTES SYMBOLS LEGEND FLOOR /DEMO KEY NOTES R = RELOCATED 1 13 POWER DATA BASE FEED LOCATION FOR WORKSTATIONS. EXISTING SUSPENDED 2X4 CEILING GRID AND ACOUSTICAL TILE SYSTEM. REPAIR D = DEMMOLISHH O REMOVE EXISTING PARTITION. D ED / GRID AND INFILL TILE AS REQUIRED. REPLACE ALL STAINED OR DAMAGED N = NEW 2 REMOVE DOOR, FRAME AND RECITE; STORE FOR RE -USE CEILING TILE. 1a CUT BACK AND CAP UN -USED CONDUIT ABOVE CEILING. 2 RELOCATED AIR RETURN GRILL POWER OUTLET © NOT USED RELOCATED FLUORESCENT LIGHTING V COMMUNICATIONS OUTLET 0 NEW GRID HEIGHT WALL PER DETAIL 5/IA -9.1 RE -WIRE SWITCHING AS REQUIRED FOR NEW LIGHTING LAYOUT �� y I 2X4 LIGHTING /� 0 REMOVE RETURN GRILL AND RELOCATE PER RCP , 0 REMOVE FLUORESCENT LIGHTING AND RELOCATE OR STORE FOR REUSE O O REMOVE SPEAKER AS NECESSARY TO RELOCATE LIGHTING ® ® REMOVE CEILING MOUNTED SCREEN AND RELOCATE PER TENANT $ _I 5 TENANT PROVIDED SYSTEMS FURNITURE. MAX. PANEL HT. 72" A.F.F. O 2X2 LIGHTING s0 TENANT PROVIDED FURNITURE DOWNLIGHT A O NOT USED EXIT LIGHT O REMOVE EXISTING CASEWORK AND RELOCATE TO STAGING ROOM TOGGLE SWITCH # 106 AS INDICATED 9 RELOCATED CASEWORK AIR RETURN GRILL - t0 CAP FLOOR MONUMENTS H AIR SUPPLY GRILL MODIFY DOOR HARDWARE TO M TENANT REOUIR NTS 0 SMOKE DETECTOR t2 RELOCATE EXISTING CASEWORK TO SOUTH END OF WALL. SPEAKER PROVIDE NEW POWER LOCATIONS FOR UNDERCOUNTER REFRIGERATOR AND WATER COOLER. _e CEILING POWER A:3.1 © 2002, JPC McldYCr, R IC SCOPE OF - - - -, WORK SCOPE - - - OF WORK i �► EXISTING CONFERENCE , EXISTING OFFICE 111 1 EXISTING 1 OFFICE 1 NEW OFFICE 103 STAGING 1. FINISH PLAN - 1ST FLOOR Scale: 1/8"-----V-0" GENERAL NOTES 1. FLOORING TO BE CARPET (C1) DIRECT GLUE DOWN UNLESS OTHERWISE NOTED_ FOLLOW CRI GUIDELINES FOR INSTALLATION. 2. WALLS TO RECEIVE 4" HIGH RUBBER BASE RB1, THROUGHOUT UNLESS NOTED OTHERWISE. 3. • c . P,41 , 0. S • MATCH ADJACENT WALL FINISH Q (PAI AND ' • E) 4. FOLLOW MANUFACTURER PROVIDED DETAILED INSTALLATION GUIDEUNES & USING MFG. RECOMMENDED ADHESIVE PRODUCT OR TOOLS AS REQUIRED. PROVIDE TENANT WITH MANUFACTURER RECOMMENDED CARE AND MAINTENANCE INSTRUCTIONS. 5. BUILDING STANDARD DOORS THROUGHOUT UNLESS NOTED OTHERWISE. 6. SUBMIT SAMPLES TO DESIGN ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. A FINISH LEGEND CARPET E BASE MFR.: J&J COMMERCIAL STYLE: FUNCTION 4670 COLOR: 322D RHOMBUS LOCATION: ALL AREAS U.N.O. EXISTING FINISH TO REMAIN MFR.: ROPPE 4" RUBER BASE 120' COIL COLOR: P150 LOCATIONS: ALL AREAS U.N.O. WALL TREATMENT MFR.: RODDA COLOR: 387.1 LIGHT TAN /PINK FINISH: EGGSHELL; SEMI -GLOSS AT WET AREAS LOCATIONS: ALL AREAS U.N.O. MFR.: SHERWIN WILLIAMS COLOR: SW1376 SNAPDRAGON FINISH: EGGSHELL LOCATIONS: ACCENT PAINT AS NOTED ON PLAN NOT USED NOT USED e p MFR.: RODDA 5� COLOR: 409.2 SURPRISE PINK FINISH: EGGSHELL LOCATIONS: ACCENT PAINT AS NOTED ON PLAN MFR.: RODDA COLOR: 478.3 PERIWINKLE BLUE FINISH: EGGSHELL LOCATIONS: ACCENT PAINT AS NOTED ON PLAN WALL COVERING W' VINYL A MFR.: MAHARA PATTERN: TEKWALL 1000 300801 COLOR: 176 MISTY MORN LOCATIONS: OFFICE 227 AND CONFERENCE 217 y MFR.: MANNINGTON 12X 12 VCT TILE 1 STYLE: ESSENTIALS COLOR: 102 STONE GRAY LOCATION: FILE ROOM; AND COFFEE /COPY CHECKER BOARD PATTERN, V 2 1PL1I NOT USED TBD WINDOW COVERING IMB 11 CITY OF T; "Itf APP !?4c D FEB 2 1 2003 MFR.: HUNTER DOUGLAS 1" MINI - BLINDS (TO MATCH BLINDS IN CORP. AREA) COLOR: 065 BRUSHED ALUMINUM LOCATION: EXTERIOR WINDOWS AND OFFICE RELITES KEY NOTES 0 REMOVE EXISTING FLOORING AND BASE WHERE NEW FINISHES ARE SPECIFIED. Q P —LAM FACED CABINETRY (PL1). SEE DETAIL 21/IA-9.1 ® PAINT TO MATCH EXISTING GENERAL PAINT. I 0 CARPET AND BASE TO MATCH EXISITNG CARPET IN "IT" AREA. O NEW MINI — BLINDS AT EXTERIOR WINDOWS AND OFFICE RELITES. EXISTING BLINDS TO BE REMOVED AND RETURNED TO BUILDING OWNER. REFER TO SPECICATION (MB1) JPC ARCHITECTS 355 110th Ave PIE ,suits too Bellevue. WA 98004 , tel 1425] 641 -9200, fax 44251 63 7 -820 0 M ON EYTREE 6720 FORT DENT WAY #130 FORT DENT OFFICE BUILDING TUKWILA, WASHINGTON Design Team .'c projec No JPC JD,JM AC 12 -16 -02 02 -100 -0646 Revisions Na DeN Desalcam 12 -20 -02 PERMIT SUBMITTAL R 01-17-03 CONSTRUCTION ISSUE 01-31-03 PERMIT REVISION Registration Keyplan RECEIVED CITY OF TIJKLVILA FEB 0 4 2003 PERM,T CENTER Sheet Title FINISH PLAN X02 -373 Sheet No. IA -6.1 1 © 2002, JPC Architects, PLLC 4 10 T .1 1 45' BRACE NON —LOAD BEARING PARTITIONS AT 8' -0' O.C. (WHERE WALL RUNS UNSUPPORTED FOR MORE THAN 8' —0'. LOCATE FIRST BRACE AT CENTER POINT OF UNSUPPORTED WALL WITH SUBSEQUENT BRACING SPACED AT 8' -0' O.C.) 12 GA. WIRE ATTACHED TO UNDERSIDE OF _' SLAB ABOVE 3 -1 /2" CHANNEL RUNNER �— ACOUSTICAL TILE CEILING SHIM HEAD AT NON—LOADED PARTITION Scale: 3" = 1' -0" J 45' 2" MAX. 12 GA. VERT. WIRE HANGER ® 4' -0" O.C. ADJ. HANGER SIZE FOR LOADING PER CODE CROSS RUNNER MAIN RUNNER 1. CONTRACTOR TO PROVIDE ATTACHMENT OF BRACING WIRE AS NECESSARY FOR SUPPORT OF THE IMPOSED GRAVITY .ANL) SEISMIC LOADS. 2. SEISMIC BRACING ® 12' -0" O.C. MIN. BOTH DIRECTIONS. 3. #12 GAGE SPLAY WIRE BRACING IN PLANE OF EACH RUNNER. VERTICAL ANGLE = 45' 45' 012 SEISMIC BRACING AT CEILING Scale: NOT TO SCALE STRUCTURE 7-- BRACE NON —LOAD BEARING PARTITION AT 8' -0" O.C. (WHERE WALL RL NS UNSUPPORTED FOR MORE THAN 8' -0 ". LOCATE FIRST BRACE 0 CTR. PT. OF UNSUPPORTED WALL W/ SUBSEQUENT BRACING SPACED AT 8' -0' Q.C.) 45 ■ _f" , 3/16"e POWER ACT. FASTENERS, MIN. 1000Ib. PULLOUT AT STEEL DECK FASTEN W/ (2) �12 -14 SCREWS 12 GA. WIRE ATTACHED TO UNDERSIDE OF SLAB ABOVE & 3 -1/2 "x18 GA CHANNEL RUNNER N ACOUSTICAL INSUL TO 4' -0" EA. SIDE OF CENTER UNE OF WALL AT SOUND WALLS ACOUSTICAL CEILING TILE PROVIDE METAL EDGE. TAPED AND PAINTED WALL COLOR SHIM 3 -1/2" METAL STUD RUNNER SECURE TO GRIDE W/ #10 SCREWS 0 24" C.C., PAINT EXT. FLAT BLACK. CONT. 1"x1/8" FOAM AT SOUND WALLS ONE LAYER 5/8" TYPE X GWB EA. SIDE. PROVIDE WATER RESISTANT (GREEN BOARD) AT WET LOCATIONS. SOUND INSULATION AT WALLS AS INDICATED ON PLAN. 3 1/2" GALV. STL. STUDS ® 24" O.C. TYP. U.N.() 4" RUBBER BASE AT CARPET TYP. CONT. MTL. RUNNER ANCHORED — TO FLOOR AT 24" 0.C. CONT. 1 "x1/6" FOAM TAPE AT SOUND PARTITION GRID HT. PARTITION Scale: 3" = 1' -0" B/S PARTITION 2 1/2" MTL STUDS W/ 5/8" GWB EA. SIDE TO BOT. OF SUSPENDED CLNG U.N.O. EDGE METAL PROVIDE ALUM. SHAPE TO MATCH B/S CONST. AND FINISH. FIELD VERIFY EXISTING MULLION EXIST'G GLAZING TI WALL AT MULLION GENERAL NOTES 1_ ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WTTPIOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE- ( 1997 UBC 1004.3 ) 2- COORDINATE KEYING WITH TENANT AND BUILDING LANDLORD. 3. PROVIDE EXIT DEVICE OR PANIC HARDWARE AS REOUIRED. 4. ALL DOOR HARDWARE SHALL BE LEVER STYLE HARDWARE CONFORMING TO BARRIER FREE DESIGN REOUIREMENTS. 5. REFER TO SHELL AND CORE ARCHITECTURAL DRAWING FOR DOOR AND HARDWARE TYPES FOR BUILDING SHELL AND CORE DOORS. 6 ALL HARDWARE SHALL BE BUILDING STANDARD UNLESS NOTED OTHERWISE. 7. CONTRACTOR SHALL CONFIRM EXISTING DOORS AND HARDWARE CONFORM TO BARRIER FREE AND EXITING REQUIREMENTS. 8. CONTRACTOR SHALL CONFIRM EXISTING EXIT ENCLOSURE DOORS AND HARDWARE CONFORM TO UBC SECTION 1005.3.3.5. DOOR HARDWARE SCHEDULE HW-a IB /S HARDWARE a LATCHING, NOT FIRE RATED. 2 PR. BUTTS 1 EA. LATCHSET 1 EA. STOP 3 EA. SILENCERS HW-x EXISTING 8/S HARDWARE HW-b B/S HARDWARE b STORAGE, OFFICES, LOCKING. NOT FIRE RATED. 2 PR. BUTTS 1 EA. LOCKSET 1 EA. STOP 3 EA SILENCERS DOOR TYPE LEGEND • CONFORM TO ALL CODES AND ORDINANCES FOR WASHINGTON STATE BARRIER FREE DESIGN. • CONFORM TO UBC CODES AND REQUIREMENTS FOR SAFETY GLAZING (UBC SECTION 2406). dElk 8' -0" TOP OF DOOR FINISH FLOOR O3' -0" x 8' -0" (B /S HEIGHT) BUILDING STANDARD HARDWOOD VENEER DOOR IN WOOD FRAME. ©3' -0" x 8' -0" (B /S HEIGHT) BUILDING STANDARD HARDWOOD VENEER DOOR IN WOOD FRAME W/ SIDEJ-ITE (-31 EXISTING DOOR 5/: "GWB EA. SIDE 0 METAL STUDS O 1- La w CY PLWD. BLKG. CAULK CAULK 1 -3/4" S.C. /HARDWOOD VENEER DOOR U.N.O. Lay) SOLID HAR 1- J II� III II DOOR STOP WOOD JAMB / AW%V EER DADOS 1 RECEIVE 5/8 " GWB L x j` 1 /2 " 5/8" 1 1/4" DOOR JAMB Scale: 3 " =1' -0" 1/2" F.R. PLWD. BLKG. VENEER GW /gg3/4" DADO 1 W3'4" S.C. HARDWOOD VENEER DOOR (PER SCHED.) REFER TO { /4..WALL TYPF3 /. " 18 1 1/2" 5/8" GWB EACH SIDE OF METAL STUDS ACOUSTICAL CEILING —1 TILE W /EDGE TRACK DOOR HEAD Scale: 3 " =1' -0" RELITE SILL DOOR /RELITE JAMB Scale: 1"=1 —0" C1TYFT;`.Vill X FEB 2 2cs" RELITE HEAD Scale: 1"=1' —0" \` ti JPC ARCHITECTS 355 11001 Are NE ‘-,Suite 100 Bellevue, WA 98004 tel R25)641-9200, fax 44251637 -8200 M ON EYTREE 6720 FORT DENT WAY #130 FORT DENT OFFICE BUILDING TUKWILA, WASHINGTON Design Team Mkt JPC Project No. JPC JD,JM AD 12 -16 -02 02 -100 -0646 Revisions Na Ckealplen 12 -20 -02 PERMIT SUBMITTAL 1 01-17-03 CONSTRUCTION ISSUE 2 0 ? —31-03 PERMIT REVISION 'Registration Keyplan RECEIVED CITY OF TUKWILA FEB 0 4 2003 PERMIT CENTER Sheet Title DOOR SCHEDULE WALL /CEILIN G DETAILS IA -9.1 © 2002. JPC Ara+kt5, PLLC