Loading...
HomeMy WebLinkAboutPermit D07-002 - SHOW POINT LOGISTICS - STORAGE RACKSSHOW POINT LOGISTICS 12610 INTERURBAN AV S D07 -002 City of Tukwila Parcel No.: 0004800003 Address: 12610 INTERURBAN AV S TUKW Suite No: Tenant: Name: SHOW POINT LOGISTICS Address: 12610 INTERURBAN AV S , TUKWILA WA Contact Person: Name: RICH FISHER Address: 18715 EAST VALLEY HY , KENT WA 98032 Phone: 425 2644813 Contractor: Name: DACO CORPORATION Address: 18715E VALLEY HY , KENT, WA 98032 Phone: 425 -656 -4505 Contractor License No: DACOC * *012NC doc: IBC-10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Owner: Name: GATEWAY OLYMPIA INC Address: C/0 MCELROY GEORGE & ASSOC , 3131 S VAUGHN WAY #301 80014 Phone: Permit Number: D07 -002 Issue Date: 02/22/2007 Permit Expires On: 08/21/2007 * *continued on next page ** Expiration Date: 05/01/2008 DESCRIPTION OF WORK: SUPPLY AND INSTALL NEW SELECTIVE STYLE STANDARD PALLET RACK IN EXISTING WAREHOUSE. Steven M. Mullet, Mayor Steve Lancaster, Director Value of Construction: $0.00 Fees Collected: $432.35 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: Occupancy per IBC: 0024 D07 -002 Printed: 02 -22 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signatur I hereby certify that I have read an governing this work will be complie City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. 7 �d`�7 • Signature: Date: Print Name: C C if— f" 4 Al doc: IBC -10/06 Permit Number: D07 -002 Issue Date: 02/22/2007 Permit Expires On: 08/21/2007 Date: c-lu- 1'o Steven M. Mullet, Mayor Steve Lancaster, Director permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 007 -002 Printed: 02 - 22 - 2007 Parcel No.: 0004800003 Address: Suite No: Tenant: 12610 INTERURBAN AV S TUKW SHOW POINT LOGISTICS 1: ** *FIRE DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -002 ISSUED 01/02/2007 02/22/2007 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 4: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 5: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 6: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IF'C 906.5) 7: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 8: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 9: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 10: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 11: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 12: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access doc: Cond -10/06 007 -002 Printed: 02 -22 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 13: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 14: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 15: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 16: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 17: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 18: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: Computer equipment to be stored no higher than 6 ft. from the floor. 21: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 22: Maintain minimum 6" longitudinal flue space between back -to -back racks. (NFPA 13- 12.3.1.14.1) 23: Where storage height exceeds 16 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) doc: Cond -10/06 007 -002 Printed: 02 -22 -2007 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** 24: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (1 PC 315.2.1) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 26: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)576 -4407. 28: ** *BUILDING DEPARTMENT CONDITIONS * ** 29: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 30: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 31: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 32: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D07 -002 Printed: 02 -22 -2007 Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Date: c a- -/ 7 doc: Cond -10/06 D07 -002 ordinances governing or local laws regulating Printed: 02 -22 -2007 Site Address: Tenant Name: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us Name: A CI -I P55 sf, ?i2 Mailing Address: / p 7/ S E . 1J �� ��,, E -Mail Address: I� l L'� v £OQ P , (Qm Company Name: CNL P02 -ATI QIN Mailing Address: ( 7/C .. VA-1 -4. /.../-44.J4 Contact Person: i [ 4i l`-- / � S " A ze- z P jt E -Mail Address: yG2 l >4 O P. Coy., Contractor Registration Number: DA-CDC—AD AD (d NCB A/ /4 G ' - z k i c9/4 -Aj/ 610 01 1O tS - 7 C .401- -CO v1 Q:\Appliations\Porms- Applications On Lin&3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh Building-Per Mechanical Permit No Plumbing/Gas Permit Public Works Permit No; Project Nc� Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Kin Co Assessor's Tax No.: OO — 00 0 5 /0 /AU i ee- V 2 N /4 lei SUUTA. Suite Number: /0 0 Floor: I S /4-(714) PO //■+T I CMG /S - 7 - i Cs. New Tenant: .... Yes State Property Owners Name: £LE Prr :t e 4,2C-6, Gvte—m Mailing Address: /660e, <ta% 7 /14 CA./ •4 12/pp City State �..No Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Day Telephone: % L .. 4 S'-4i;/ 3 se tAi � " O3' )- City State Zip Fax Number: aS3 — > •CO Si 3 GENERAL CONTRACTOR INFORMATION - . (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) ,e ,1 w 4- City State Day Telephone: t/�S`— 04 —lie/ 3 Fax Number: .P-S - TrC H - / - 90 e( Expiration Date: C _1 o ex. Zip ARCHITECT.OF " .RECORD . -' All plans must be wet stamped by Architect of Recor Zip City Day Telephone: Fax Number: All plans must be wet stamped by Engineer of Recor 4 41,1 (k e/zo bethA ) S r Wav y Gat itYr b4 .L '- t),4 '?/- "/ City State Zip Day Telephone:(8'lgL)J/O • 3$/0 Fax Number: ( Y / > • 32 / 3 Page 1 of 6 Valuation of Project (contractor's bid price): $ / 0_, �t# 6 D Existing Building Valuation: $ /?9 Scope of Work (please provide detailed information): 5 (, P P L-4 /A- S T4-z— A r 4 �Z �C Y ► V e S T 9 Le' S T st-• reet-G.k - t ' 3c t S 'r N (.V 4IZ &'. ,Ecru 5 - , Will there be new rack storage? 1Z L... Yes Q:\Applications\Forrns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑ .. No If yes, a separate permit and plan submittal will be required. 'rovide "All Building Areas;;" 2/0 sst Fr PLANNING DIVISION: ,tj /,g- Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: g Sprinklers ❑ Automatic Fire Alarm .15`, None ❑ Other (specify) A..10 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Fixture Type: Qty Fixture' Type: .... Qty . fixture Type: Qty " Fixture Type: Bathtub or combination bath/shower Drinking fountain or wa ' cooler (per head) h fountain Gas piping outlets Bidet Food -waste grinder, ; ' commercial Rece or, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single : ead trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain wate system — per drain (' de building) Water heater an r '' vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repai ;r alteration of water pipi _ and/or water treating eq •ment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing wor ontractor's bid price): $ Valuation of Gas Piping work (c . < actor's bid price): $ Scope of Work (please provide detai information): Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets Q:\Applications\Forms- Applications On Line\3 -2006 -Permit Application.doc Revised: 9 -2006 bh installed and the quantity below: State Zip Page 5 of 6 PERMIT APPLICATION NOT — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name: 04 Mailing Address: 9 ,r)-> 4-Lv a-thh AN) P /v Date Application Expires: 04 Ga 4 Date Application Accepted: 01 6 crij Q:UpplicationsWorms- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9-2006 bh Date: /d7a -7 JO G Day Telephone: 4 t , -S V-- ei ro l< &ri-f t-1,4 rot City State Zip Staff Initials: ,� Page 6 of 6 i Receipt No.: R07 -00264 Initials: JEM User ID: 1165 Payee: DACO CORPORATION TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0004800003 Permit Number: D07 -002 Address: 12610 INTERURBAN AV S TUKW Status: APPROVED Suite No: Applied Date: 01/02/2007 Applicant: SHOW POINT LOGISTICS Issue Date: Amount Payment Check 126412 263.80 Account Code Current Pmts 000/322.100 259.30 000/386.904 4.50 Total: $263.80 Payment Amount: $263.80 Payment Date: 02/22 /2007 12:20 PM Balance: $0.00 _.._ , /4.I a.. dor.• RPrtint -0R Printadc 112 -92 -2007 Payee: DACO CORPORATION ACCOUNT ITEM LIST: Description doc: Receiot -06 PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0004800003 Permit Number: DO7-002 Address: 12610 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 01/02/2007 Applicant: SHOW POINT LOGISTICS Issue Date: Receipt No.: R07 -00007 Payment Amount: $168.55 Initials: JEM Payment Date: 01/02/2007 12:57 PM User ID: 1165 Balance: $263.80 TRANSACTION LIST: Type Method Description Amount Payment Check 126152 168.55 Account Code Current Pmts 000/345.830 168.55 Total: $168.55 • 3331 01/02 971 TOTAL 168.55 Printed: 01-02 -2007 • Project 1 i, Type of Inspection: -digI Address: / / Date Called: Date Wanted: ^� --in Special Instructions: V971 70 - 3 -1 Z-- p.m. Requester: ' (/I Phone' No: Z6' -- 4 . lS`<` INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit j KAp proved per applicable codes. Corrections required prior to approval. COMMENTS: (9 ri $58.00 REINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: 'Date: Project: Sh 0 w fc,,,i. /05 ; s4).4 s Type of Inspection: Address: } za I p T , ' � x ,N, b, Suite #: Ati s ' Contact Person: Special Instructions: Permits: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER R Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Word /Inspection Record Form.Doc 1/13/06 0o7— oca. PERMIT NUMBERS Corrections required prior to approval. COMMENTS: Inspector: 5W 7 - Date: . 3 )12.-to 7 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 INCREASING YOUR PROOUCTN/TY DACO MATERIAL HANDLING & PACKAGING SOLt177ONS January 2, 2007 Chief. Don Tomaso City of Tukwila Fire Department Fire Safety & Inspection 444 Andover Park East Tukwila, WA 98188 Dear Don, This building has an existing sprinkler system. The commodities to be stored are Generators and electronics. The generators and the electronic equipment are packaged is corrugated paper boxes. The generators are also on a wood skid for ease of movement and shipment. The maximum height of the top of the top load will be at 20'. The sprinklers heads are above 22'. Sincerely, Rich Fisher Project Manager Daco Corporation CIT JAN 02 2007 PERMITCENT -R BY G. OHANIAN RAdK DEFIIC N & EN(IINEERINti do. DATE. 11-20 -06 SUBJECT SHOW POINT LOGISTICS 12610 INTERURBAN AVE. SOUTH BLDG. "D" SUITE #100 TUKWILA, WA. 98138 PER CBC 2001 EDITION STORAGE RACKS CAPACITY: 3200 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -11587 412 WEgT BROADWAY, EtUITE #204 LE/DALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240 -3813 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: I EXPIRES 12 -26 -07 r' • • • • r SHEET NO 1 JOB NO.. RD -11587 F.71 n, nntyy CITVOFTMANILA JAN 02 2007 PERMIT Doi --c�2 BY G. OHANIAN RAdK DEOI(N & ENCINEERIN( d0. DATE . 11-20-06 SUBJECT ` F 4 -. ... ..,... . } SEISMIC DESIGN _ S QS xI V— Rx 1.4 WORKING W =D.L.+ 3 L.L. 96" FRONT VIEW BEAM 3200 #/ LEVEL +25% IMPACT LOAD 1800 #1 BEAM STRESS 1 =1 R =6 MOM. CONN. R =4 BRACED S =.9 LOAD PER COLUMN L.L. =-2-x 3x3.2K — 3 . 2 K 3 2cm. W= .10.L+ 3.2 3.3 K .9x1x3.3 = 35 LONGIT. K NGIT. 6 x 1 .4 V = .9x1x3.3 53K TRANS. 4x1.4 • IBC 2003, SEC. 2208 412 WEI4T BROADWAY, QUITE #204 LENDALE. dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SIDE VIEW I =1.23 S=.68 FY =55 KSI. S =1.36 (USGS MAP) Sias =1.36 (EQ. 16 -38) S =f x1.36 =.9 (EQ. 16 -40) LONGIT. SEISMIC M 96 "x1.8 K - "K 8 S 3 3 "K — .65 <.68 A _ 5xWxL3 =.51 "< 96 =.53" 384x1 xE 180 .35 K SHEET NO. 2 JOB NO.. RD -11587 By G. OHANIAN RAdK DEOICIN & ENc INEERINc d0. DATE . 11 - 20 - 06 412 WE BROADWAY. �1UITE #204 LE? DALE, dA. 91204 SUBJECT .f. TEL:(818)240 -5810 FA%:(818)240 -3813 COLUMN ANALYSIS M COMBINED STRESS RATIO Pa + M ax 13 + 23 = .73 <1.33 Fy =55 KSI A =.75 S =.7 r =1.2 r =1.1 BASE PLATE ANCH. TENSION = 11— ( ") =.53 ANCHOR SHEAR = • 2 = 11 K (2) -1/2 "0 HILTI KWIK BOLT 3 ESR -1385 OR EQUAL. (NO INSPECTION REQ'D) DESIGNED FOR 1/2 STRESS MOMENT AT BEAM CONNECTION 7/16"0 RIVET A = .1 Fy =79 VC = .1x79x.4 = 3 Ma =3Kx4 "x1.33 =16 " CONN. 2 PIN CONN. Kl = 62x1.7 =88 Fe= 11111 37 rx 1.2 ( ) 2 rx r - 1 1 — 40 Fn =Fy(1— 4Fe ) =33 KSI P =F xA =25 P ° Pn =13 — 1.92 Max =Sx.Fb = "K 9.5 33 11I SHEET NO. 3 JOB NO. RD - 11587 7 3/4 "x5 "x3/8" BASE PLATE BY G. OHANIAN DATE. 11 - 06 SUBJECT RAdK DENI(N & EN((INEERIN( do. 412 WEJIT BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240-3813 OVERTURNING TOP LEVEL ,LOADING 53 "x.5x1.15 =113 "K M .17Kx2x186 " =63 "K MOT = • MR = 3.3 K x42" = 138 "K MR =1.2 Kx42 "= 50 " K NO UPLIFT LOAD TO DIAGONAL P = .53 Kx2x 42 = 1.2 K F =55 KSI A =.31 r =.48 Q =.74 L= 46" 3/8 "r6 BOLT V0 =2.0 Kx2 =4.0 K CHECK SLAB 00 _ 3 0' 1000 F 13.8 KSI 1500 = 30 <1.6 2500 =80 50 P 3.5Kx1.33 =4.3 3.3x144=475 =22" M= ( 2) x1000x x12= 1500 "# S= 12x5 = 50 6 UPLIFT = 63-50 = .31 K 3/5"% BOLTS ........_ TYP. 3300 I SHEET NO 4 JOB NO.. RD - 11587 5" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL January 25, 2007 Rich Fisher 18715 East Valley Hy Kent WA 98032 RE: CORRECTION LETTER #1 Development Permit Application Number D07 -002 Show Point Logistics —12610 Interurban Av S Dear Mr. Fisher, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, arshall hnician encl File No. D07 -002 City of Tukwila akA P:Uennifer\Correction Letters\2007\D07 -002 Correction Ltr #1.DOC jem Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: January 18, 2007 Project Name: Show Point Logistics Permit #: D07 -002 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The floor plan (sheet R -1) showing the racking layout is not consistent or identifiable with the Floor Plan sheet A2.01. Please darify the floor plan or darify the location in the building for the new racking. (IBC 106.1.1) 2. Identify exits and exit signs or emergency lighting. (IBC 1011 & 1013.3) 3. Provide dimensions and square footage of the warehouse. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D07 -002 DATE: 02 -15 -07 PROJECT NAME: SHOW POINT LOGISTICS SITE ADDRESS: 12610 INTERURBAN AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building i vision Public Works DETERMINATIQN OF COMPLETENESS: (Tues., Thurs.) Complete Comments: PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY Approved with Conditions ❑ Permit Coordinator ❑ DUE DATE: 02-20-07 Not Applicable ❑ No further Review Required DATE: DUE DATE: 03-20-07 Not Approved (attach comments) ❑ DATE: Planning Division d Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D07 -002 DATE: 01 -03 -07 PROJECT NAME: SHOW POINT LOGISTICS SITE ADDRESS: 12610 INTERURBAN AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Buil.' g l 'vision Public Works DETERMINATION OF COMPLETENESS: (rues., Thurs.) Complete Comments: Ib PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Notation: Documents/routing slip.doc 2 -28-02 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: tin . Fire Prevention ❑ Permit Coordinator DUE DATE: 01-04-07 No further Review Required DATE: Planning Division REVIEWER'S INITIALS: DATE: Not Applicable ❑ DUE DATE: 02 -01 -07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) E of [(,1A- Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: • n City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4g // 9/ Q 7 Plan Check/Permit Number: D07-002 RECEIVED CITY OF TUKWtl,,q, FEB 1 5 2007 PERMIT CE1. TEr -, Project Name: Show Point Logistics Project Address: 12610 Interurban Av S Contact Person: eei C#1 &#' 46- 2 Phone Number: a0 - z/d6 Summary of Revision: ie6 -'1/< S Pc 4A3 D 24 N G. (l C 8� cis i s 7 w, - rte ea-' 4./ &, 4-L . 77-4 rs a-v /scs- nl2 4-w /ti� ,C c-t2 S tom, - T - 1-0- X..r C I6�►J S 0 4-L s o SE -( Cri Lv ft-2 e U-t) c e 7), M O-+vs t ar-IC a S 6/0 4 2 e- r- errA ! cuotre - vs , 0- - r Po ,' ■rr 3 ). Sheet Number(s): „2 sue- -V-S_ G 0&\..) I S �b D 2114.4.,/ &34 /Z 1 G - V I "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: f Entered in Permits Plus on License Information License DACOC * *012NC Licensee Name DACO CORPORATION Licensee Type CONSTRUCTION CONTRACTOR UBI 601946293 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 18715 E VALLEY HWY Address 2 09/29 /2005 City KENT County KING State WA Zip 980321241 Phone 4256564504 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/10/1999 Expiration Date 5/1/2008 Suspend Date Separation Date Parent Company Previous License DACO * * *101JC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date KATONA, B KEVIN PRESIDENT 05/01/1999 DUFFIELD, STEPHEN L VICE PRESIDENT 05/01/2000 SHIELDS, EDWARD E CHIEF EXECUTIVE OFFICER 01/01/1980 09/29 /2005 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Account Effective Expiration Cancel Impaired Bond Received https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= DACOC * *012NC 02/22/2007 I I I I a I I A 1. GENERAL A VERIFYANDCOlNFINT ALL D AND DOS NGC0lNDITIONS. HO1IFYO IERs REPRESENTATIVE IW WANNYG2MONTPCn1RE OFMY D19CA VANCFS ORCObDir10NS ADVERSELY AFFECTING THE DESIGN OR PROGRESS OF WORK PI601110 PROCEEDING 1 NTH THE f9IOF WORK AFFECTED a COMPLY LAWS MID INCASE OFCO UCTBETWEENMETHO SORSAiDAfRD6OFNSTALIATKRCROMER LQIWJTY. NOTIFY ARCHITECT ( MULVMNYG2MCHITECTURE)OFMLCONFUCT& ALL WORK SHALL CONFORM TOME 1997 U.AC.ASMENOEOMOADOPTED BYTE CITY OF TUKWILA. C. OBTAIN SEPARATE PERMITS FOR ALL AM MONS MDA)R MOOWICATIONS TO: 1. MMECHANOCAL 2. aECTRICJM. 3. RARE SPRINKLERS 4. FiRE 5. 9GNM E N ACCORDANCE WITH ARD AS REQUIRED BY ALL CODES AND REGULATIONS. Q CONEUT DI REOURDENTSINMESE SPECFICATIONSFORSTNAARDOFWORKMANSHIP. PERFORMANCE ANDQUAITY. 1. WERE MMATBIALS. MORES OR EM MMERT IS NOT SPECIFICALLY O@(TFED. THE CONTRACTOR WELL BE REQLINEdTO SUBLET SIMPLES OR NFORWAiION DETEPNN INGQIMIJTY AND PERFORMANCE MANC:E TO OWNER PRIOR TO ANYTIME E. COORDNATESUPPPLNEiSAMSUBO ONTRACTORSFORPROPERSEQU ENCEOFOPERATIONS PREVENT RESSOFWOi K R. MARTIAN STRUCTURAL NiEGEITYOF ROOF AND BUIDNG51ELS1IWC1URE. DONOTUSE2X ROOF STIFFENERS FORCEINCSUPPORT. SPRIMERPEE SUPPORT. MECHANICAL DUCT HANGER SUPPORT. ETC. DO NOT CUT STIFFENERS. ANY SUPPORT OF NEW ROOF TOP EQUIPMENT SRWJ.BE REVIEWED AND APPROVEDBYAWASHINGTONSTATELICENSEDSTRUCTURALE (GN®t CALCULATIONS AND (ETAS STWL BE PROVIDED FORPEIiIITSU9IBITAL PURPOSES G. CLEAN UP 1. DAI.YSRECLEMOP: AIL MJBBiSH MIST BE REMOVED AT ME 910OFEA HWEEIOJAY ERE DE SPACE IS OURREN1EYOCCLIPED. VACWMED N THE MEDIATE WORK AREA. 2 FNALCLEANUP SCOPE OF CONTRACTOR'S WORiCTOBEACOI?LETE TURNKEY CLEANUP OFTHE BIN EAREAOF WORK MINN ME TENANTS SPACE N0.UDNG.8I11 NOT LII1B TO. ALL FLOOR COVERINGS. INTERIOR WALLSAND GHAZVIG. MD INSIDE SURFAC 3OF EXTERIORGLAZALG. 3. OUNPS1ERS: CONTRACTOR TOPROTECTASPI4 TPREVE(TWMAG£TOIHEPAVEDSURFACES A 2. SITEWORIC- RBMONAL OFEDOSTIIGEXTRIIO® CONCREMECLIRBINGWERESHIOWNONRJW REMOVAL AND RELOCATION OF EXISTING LANDSCAPE ARE AS SHO:YN ON PUN INSTALL ASPHALT PAVING ( t500SF.) ATNEVAYPAVEDAREASON RAN TOWATCHDlSTING PAVEMENT SECTION. 3. CONCRETE A. ANY iREAROF TRENCHED STAB MFASWLLDE DONE PE RACISTANDARDSUIT UENCA2900PSI28 DAY CONC. LEAK SLLAP36 SACKS PER CU_ VD. CONGCOVEROFRERNF (FANY)SFWLBE WEATFERRFACE -1 W INTERIOR FACE -Er EARTH FACE -T ENSILING VAPORBAR IERMDCONUARYBREMEE EAM FLOORSLABSIWJ. BE RENREOMD REFLACEDASNECESSMY TORESTORERTTONYINTEGRALBA RRERTOMOSHJI E. & MASONRY: NOTE REQUIRED S. METALS A. FRAI & CR EQbNATHYT AS DETMED ON DRAWINGS, WRH FIRE BLOG0111'AS REQUIREDMCOOE BO1Tp1 PLATE cora fcTON 111•DI ETERRAUSETAT2COC.PBETRATEINTO CONCRETE 1- Ui'1A@ll um. 6 FURRIYG:1 GRABBER' CREQULVNB(T.ASOETMEDONOFEMMIG& RIROUTRAIN LUGER& CONCRETE ETC. AS RECANTED TO COVER C. PROVIDE GAMIC INSUADON BEIDEEN OISSIMIARIETNSWERENC ONTACT. S. CARPENTRY A GENERA: PR VDEBLOCKIPMASMIAi9DFORE I MM NT .ETC. a PLYWOOD. ,Tor LOURED FAG C PLASTIC LAIMATE: NONE REQURED Q CASSEIRY: NONERECIURE 1 E. ORAFTSTCPS: NC E REOU R£Q F. SMIOKE CURTANIMARD& NONE RECURS). 7. VERTU& MOMOISTURE PROTEQTIOR A. MUTER VIOPJCLtnBRDISPE RARTISEENSPE3?FO RIEDNMTIMMEOSTMG5)3i#EA7EEDi. SEMINSUATEDIKROING SMOTE NEWNSUATDONIMO IKUNIO0NFOWMTOwA9MFsGTCNSTATE ETERGTOODE FRESCRPTHE RECURBENTS PER OEMS S AOOO,PANYIYG PENRT SUBNITTAL. B. ROOFING: T. RASNN' OCOUNTERA94ALLPBEETRAi1ONSOFROOFNG. ROOFPATGINGIRATEASPHPLT BASE LMIATE3!'ALCOPAT$EV EM00ST GROOFls . 2. PEACE ROOF NOUNTMEiOURENTO11 CURBS TELiM&CPEs DFORPRormo ANAGE OVITSEESOFQ118 &APPLYROOFTNGIAAT ILAMIKO OAR. OPCURBTOPROCAUUCOML ALL WAS AS REOLI EDmENSURE 3. V6Rll: YCODIILONSOFB CROIAG9EL ROOF 1iiARIAITY.ALL WORK 9'INILLBE PERFORMED !V ACOOMPACE IMIT64LSOFREWAARMTYTO INSURE ENITOLIFEENTITAIRRITYRENTMS 111 FI,FJICJE C RIOOFAXESSOFTER TING1vOOFHATOLUADOER &MIGHTS.ElC 8. DO(RRSAINDORS.RUMORAiE A 000115. 34 'evr.r 1,3T THI00 SQO 0:11E 11000 DOORS. UNLESS TEREDMWSWITTE NEW DOORSSAIKL ITATOTOGSTNCsBEADOiGSTA pas . 1. ALLEX. TOOORSDNU.BEOPE RMEFRONDEFaS GE1UT.- FOOTi(SEOFNEVORNAYSPECM. 10117AL OCEOREFFORT. a MAIM LNNATi7iF71STMVGBULDIIGSTAIOANDS C HA3DRAme T. A lINIKNI EITTSCIBI E LOOCO PARYCIRECIA. IEDUL AS APPROYHDMOIRIEt MDTEVEIT MUCH EAMNSBULOIGSTAI NDIS. • TUKWILA COMMERCE CENTER 12610 -12618 INTERURBAN AVENUE SOUTH, TUKWILA, WASHINGTON 98168 GENERAL NOTES A 2. AU. HARDWAREUSEDN ACCESSIBLE BUILDINGS AND FACILITIES SHALL CONFORM TOTHE REQUI EiENTSOFiNASFWGTON STATE RULES AND REGULATIONS FOR BARRIER FREE DESIGN ( VAC 5130)cHAP1ER 11 3. VERIFY ICEYING REQUIREIENTS.SPECIALTY REIMS AND QUANTITIES REQUIRED FOR COMPLETE N STMLATiON PRIORTO ANY MIRK. D. GAA21N& 1. PROJECT GLAZINGSUBJECT TO FEDERAL GLAZING STANDARDS AND GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCETO THE REQUIR NTSOFCHAPTER24UB.C. 2. ANY MODIFICATION ORADDITiONTOSTOREFRONIFRMII IG SHAU.MMATCH DOSING STOREFRONT SYSTEM. ASS A FLOORING: EJOSTDNGNEW AS NOTED ON PLANS. 1. CARPETING NEW 30 OZ DIRECT GLUE DOWN APPLICATION. COLOR SCO.ECDON BY ONER 2. T1LE SHEET VINYL FLOORING Ri RESTROOMS. COVED UP WALL S TO COFORMM TO UBC 807.1.1. COLOR 1O BE SELECTED STOVER. 3. BASSE4• ROPPE VINYL BASE N COLOR COORDINATTD WITH CARPETING. TO BE SELECTED BY mut B. GYPSUM WALLBOARD: 1. Sib' GYPSUM BOARD. TAPED AND READY FOR PANT. 2. ATTACH TO FRATINGFURRING WITH 1' G.W.B. ScL EWSATW O.C. AT PM B. EDGESMD 1? Q.C. AT INTERIOR SUPPORTS. 3. 508' MOISTURE RESISTANTGVPSUM BOARD REOAREDATWET WALLSIRFSTROOW WALLS. 4 508• TYPE TOW BOARD ATANYRATEOASSRM1ES RENEWED ONDRAWINGS. C. PMIT: i®.LYMMOOREORAPPROVVIDEQUAL 1. GBIERAL ONE COAT LATOCPRIME RANDTWDCOATSINTOIORLA1EXEGGSIEIJ. ENAMEL D. SIJSI UlOEDCEtNGS: NEW TOI MATCH EXISTING BAITING STANDARD: 1. IAYETA000STiCAL BOARIk ARMSTRONG 7x4• XSIS' MIIEOAAD RANDOM FSSEJREO PATTERN CHUNNG TILER VERIFY MATCH WITH DOSTING BUILDING STANDARD. 2 SUSPENSION SYSTEM 2: X4' IEAVi - OUTYCOMM ERO.N. -IF? WIN AND INTERMEDIATE TEES. NO. 12 GAUGE HANGERSAT4•-01'ON COTTER EACH WAY PER OB.C. STANDARDS. CAPABLE OF SUPPORTING 160POUNDS. ATTACH TIANGE RSTO STRUCTURAL FRAMING MINERS WITH UV SCREWS PENETRATING 1- UrNTOSTRUCTURE. 3. SUPPORT UGNTFIXTUERESWEEHWORD_ 12GAUGEHANGERSIROUFIXTURE TOSTRUCTURE ABOVE LIGHT FD(TURESWEIGHNG MORE THAN 58 POUNDS SHALL BE SUPPORIEDBY 4IWIGERS. ONE M EACHCORN ER 4. Ca IGSHORICONTALTOATCLEiUNCEOFiNIII 0-0'UEASIUREDEACHWAY. GROTO ROOM A THROUGHOUT. 5. PROVIDE SOME BRACINGASREQUIRED BYOODE IL SPECTATES A FIRE EXTNGUSHER& PROVIDE 2A IOBC PECOOE ONE PER 3000 SF. MMA10iW 7T-Cr TRAVEL. OSTMiCE FROMI MOPING: 11. (QINNIBR: NODE REQUIRED a. FURNISHINGS A VCOWBUDS. EOSTNGTORE MARL 13. SPECIAL CONSTRUCTICTENONEREQUIE It COMENIGSYSTEM NCTEREQUIRE) 1 CHANCAL(BYSEPARATEIWACI IT) A. PLIORBNG (SYSEPARATE PLUMEM KRIM 1. WATER CLOSET: AMBIC. AEYSTANOARDELONGATEDC .MET BANTER FREE 000E MTH SUPPLY PFEANDSCiDOLSONTESEATWAiTHCPBI FRONTANDNOCOVER 2 LAVATORY(WALLMING) -M ERK.MSTAMINN II BARRiERFTiEEM OOl3WIH HAMCIPACCESSIBLE FAMICEF. 3. WATER /EATER EL ECrRICUNTFSET DAID LOCATEDPERMECIWaCJAL( GENERAL OONIRACTOR VATS RHEAT R SHALL BESTRAPPEDATA POWWOW DEUPPERUI AND DELOWERMOFISVERTICAMENSIONt THELIOWE RSiRaPSIWLENOTTESSTWAN4' ABOVEMYOONTROLS. UP.C.5105. B` GAS Ma ND E FACE OFB * SIGOR107AROOFIrG. CORE OM THROUGH EXTE IGRwML. WADI I IGTONNEFACEOFUCTBIORNALL ATUOIMINGTORME FACE OF UND ENDOW TOROOFSTRUCTURE RUN PENG UNDER AND SUPPORTED FROLA ROOF STRUCTURE C. FI ESPRRMEJR& ADOIDONSNSMODRGTIOIGASREQ UREDBY000ENDI PA PAMPHLET t13.SPRIM ERR HEMS coarnEo MTHMi CERNGI ORDIMEREFFASEE. SERNMERSTSTEMVAIL NDECPARA ETOALL AREAS ASEIPMME FERMI ISR6QLLFREDFCRDOOFTCJLTIOfS TOME N1TC A11CSPRIMERSYSTEM NOM FIRE Pow SYSTEM. TIE RAMS ANDSPECFGLETUIISETFESYSTATOVU .8E SUE MIT113)TODECITYOF TUKWILA FORIEVIEWANDAPPRIATILERIOR TONSSiMNCEOFSUOI AF' NIM O HEAflMC.VE NTWGMDARCON OMONINCs: NefROOIFEMVONSREQUIREDTOOOSITOGIEOG SYSTTAtOEEHY SEPARATE IECHA C1CALPElRM E ELECiIMPL(BYSBARATEMari) A UGHTLIGt 10051i16) L. META_ 2:4 nC( a31tUBEIAYIIRLJORESWIFRXi1JRES HUH E1AERGY UEE E6T S NIP= 00 RYHRHUON NGED6£T NOSIIIIC NG E U RBHHTSOF OXIE MDLOULREGUUMONS.SOOFEOF MISIC INCUIDESiIUMAT =OFE7OPINGRGkJIRESM) N S T 1 M I A 1 l O l 6 CF PEW F000 ESIAiOREDON REFLFCT DCA IG 2 L AMPS. SYLYAMR SFAINONIRRSS 'COOL NOV 32 TOUTS FERLALPRAMS. %MEVM OT 11HTH OUDINGSTAtAH LEIS. 1T ELE RCAOU E'TS: t RETERTOORMINGS MO 000RUNATEIMMONNERLOGIUKINSOF Ai ROINLENTO E ADD DMRaOCATADMADEERTt11US C COSTILG SEFRMMCE WEL BESRSJ FROINA TE'.MN(TSPACE TiDAR13E TEPEE S'ltCES. 1165110RICWU.LEPAVETAIDE RASEPAWATEHECTIOCAPERAT • TENANT IMPROVEMENTS FOR: JURISDIC'T'ION: CITY OF TUKWILA A PROJECT CONTACTS OSIER RREEF REAL ESTATE WYESTIAIR MAAiNANERS 16000 CHRISTENSEN ROAD. SURE 101 TUWTLA WASHINGTON 98188 ARCHITECT: MLVMNYG2 ARCHITECTURE 1110 112TH AVHHUE NE:. 1500 :: - ,_,. nu, : �� FAX 4263.2147 CONTACT: HEATHER H ANH YA IAMOTO CONTRACTOR 10 BE IJEIENEO TENANT: TO SE IEIBmEO PROJECT DATA PROPERTYADDRFS& 12610 42G18NIERUBANAVEMESOUTH. HAMRA WASHINGTON 96160 TAX PARCB. MNIBER 1000.400 03 MIDING 1997UBC Q (IM RE 72.0245E 1 PERIDM AREA: 30,000SF (OFTCE 3614 SF3VAR@LOUSE 26.386 SF) TYPE OFCONSTRRICITOI: V N AREA OCCIFANCYGROIP: B -OFRCE S1 STORAGE; F -1 WAREHOUSE ZONE CO (COMIERCIATAIGHT INDUSTRIAL) PARKING NEEDS THIS T.I. WAREHOUSE L+iOOOSTALLSREG1 RE OFRC :311000STS1.1 tEQtUIRB) SLDTEA: 1. OFFICE 634 SF RSfQLS) 2 vonEmouse 5.3369F MIS) SLR D` L OFRCE 1.364SF(4SALLS) 2. wAaBDUSE 14536SF(5Si A S) S JIEC: L OFFICE 1.6765F(5AHL9 2 WAREHOUSE 11304SF(SSTMLS) 1a►JILPN001GSTAlILS LEt iISTALIIS 1703E 3 MAILS IBNTHED. S11131PAE6MIGSTNLSTOBE STS scrat OF2PPAIONG STIUSGMEIQ DRAWING INDEX AU9 ARM AZN ROORRAL ATM iRi3HJ;GTBACEUNSRALAIIDE>ET.AL Au! eILJMM DROORN MS►R OETARS. LAID iMTBRHOR ELEWR TORS MGI SLEOETALS&SCMDLIiES • • PAMELA KEY PLAN -0)- SCALE NOSCALE LEGAL DESCRIPTION VICINITY MAP -S- SCALE NOSCALE THAT PORTION OF C.C. LEMMA/RION CIMINO. 37, SECTION 10. TIYANSHIP 23 NORM RAW* 4 EIGLIMIL,, RECORDS OF 1014C01/11Y.OESCRIBED ASFOLLOWS: 8KiI3WGATA POINT MICH BEARS NORTH40' 0105* WESTCFADISTANCEOF9120. 15FEETMAMTLE MONUMENT VWAT THE POINT OFNiERSEC IONOFACURVEONTHE CBIIENIE OF THE DUWAMMISHR ENTONJUNCTION ROM). NOW PAVED. SAD POINT OF INTERSECTION BEINNGGAPPROXIIAT9.Y 1.000 FEET FASTAND20 FEET SOUINOF THE 1(4 COPIER BELEWEN SECTION 14 AND 1.5, TOWNSHIP 23 NORTH. RA ME EAST WM ; DUKE NORTH 49x24'WESTONAOIRVE 150 FEET DISTANT FROMM/ PARALU3. MTH THE CEITTERLIE OF SND DUMMER RENTON AMMON ROAD A INSTANCE OF105 FEET TOA PONT WHICH BEARS NORTH8 1. 4TMSEASTAIJISTANCEOF199tUFEETFROHMAMMOLELUBITiIN AT THE ENDOFACOLNSEON THE C91TERII EOFSADDUWAIRSH R NTON,AUNCTION ROAD. SAO END OF CURVE BEING APPROXIMATELY 1200 FEET NORTH AND 140 FEET WEST OF THE U4 CORNER BETWEEN SECTION 14 AND 14; THENCE NORTH 49'24' WEST A DISTANCE OF 2535 FEET: THENCE NORTH 073E EAST ADSTANCE OF 52FET TOTE TRUE POINT BEGIMINQ THENCE SOUTH 824030'FASTAOISTAI CEOF590FEET; TH E NCENORTH S9 '22YJIrEASTA015FANCEOF61335FEET; THENCE NORTH 075737 W EST A DISTANCE OF 341 FEET. MORE OR LESS. TO DE LET BMOC OF BE OUWAM5I1 IRNBI. SAD U3T 81 W C EIOG ALSO 1W NORTHERLY BOUNETARY OF C.C. LEYNS DONATION CIAM THENCE SOIRHWESTERLYA.ONGTIE tzFT BANKCF TIE SAD OUWAADSEI mat OT T WESTETEYLIIEOF THE TRACT WREN DESC[I :ix THENCE SOUTH 07317EASTADISTMCE OF 193FEET. ITOREORLESS. TOTHE POTWOF BEGRNTIR SITUATE N11ECITYOFTUCWN . COIJNTYOFTONG.STATEOFWAS HYGTON PARCIL R ASTRIP13F ENID 16FEETTIVADTIL OESCRIBEDAS FOLU.OW& EGEI IGATAPOINI NiWEC. C. LEWISOONA11ON .i7 SECilONmuio nESLAP 73NORTH. RANGE4 EAST. RN MICH BEARS NORTH WOW NEST AOSTANCEO F920. 15 FEET FROM THE CBNTBI. IEOFiEEOUWA66511REN TON ARCHON ROMD = PAVE% SADPONITOF .Y1J100FET(ASTAND20 FEET SOUTH OFD EU1CORiNERBEIVEEN 14MD 15.TOVINSIAPZIN ORn1.RANGE4EAST .WM..RECORDSOF10NGO0INIY: ALICENORTH491'24' MESTONALME150 FEET mama IRON ANDPAG ELNMI HECAtMEN* OFTHES4DDUNAI09HRENTONJUNCTIONR CIAD.ADISTANCEOF835FEE" TOAPONEWHICHBEARSNORTH874(15'EASTADISTANCECF TAU FEET FROUAMMOM> MB( T1 } *AT11EENDOFACOLNSEON1EC9(IBRU EOF11ESOD WWAYSH RBRONANCTIONROAD. MD ENO OF CURVE BE GAPPROXIMATELY 12O0 FEET NORTH AND410 FEET 'MST OFTIE VI CORTE RBE3IGSEGTIO NSi4IND 15C THENCE NORTH 49 W WEST A INSTANCE OF 2535 FEET: TIE N. CENORTH0916 ' TIERCE NORTH 0016 W EST 16.155 FEET TO TIE PONT OF EGINIMM TTEICESOUR100'3BSOLnH16,155FEET: THE3ICENORTH 874037 WEST 11757 FEET TOW EASTBRLYWQROF WAY LIEOFT1EP ET 50(N) aEc1RIcRA&wAY THENCE NORTHWESTERN/LOW SAID W RGINOFU E RIGHT OFMITA INSTANCE OF213FEET: MILE NORTHFASIE3iL.Y.RADEALLYFIiOMI THE SAD EASTBaY(IGHTCF WAY LPAEAU1S1MI EOF 16 FEET; TIE NCESOUTHEASTERLYCON( ENT RIC1MRTHANDPARPLUELTODESAI DEASTERLY ETOAPUNTRITC 7HBEARSNORTH82 '40x30'NESTMOMDEM10NiOF motaaa STRIATE IYTME art OFTU MU1/4C NITYOFIONG.SIATEOFWASEINGTOtt PARCELQ TRACT47ERIVHRSDEOHERUMMIRA 1S.ASPERRATiECORDEDETYMA* 190F RATS. PAM 74.RECOROSOF PEIGOATITY: Emwr THUPORTMITERECEIS AT4Y DING %NUNDE16 FOOT =RP OFUM MOWED /SOW PS1V51011k SITUATE IN THE CHIME TUNNIA0OUNIYOF N .STATEGFWA9iNGDON. 1,1112 I.Q STONE ILA THECTWOF T1 ONA001.10YOF IQV STATEOFTEEDNIGTQ( MA ME M EADZIENTIFCR mommamemums ASGRAMMBirMIS RUMBITtRECORD EDIDRIERRRECOONGNO.73/003M5t STRMRE NAG CRY OF TUOIAACOLMYOF STATE OF1RSHMGTOR DE AeOVELie'GA resam iOEt DESC] 10ESD EI`STNEPROFEFitIYASI49UR®IiTHE RIVERENCIIIRECONISTIMENT. _ /t _--!� , ` ' �y t • THATPORTiIOIOFCGTEMOORPOIQN 0114 StINNINGEASEEfRIYOFTRACTP .fiIVE IEMERM1tRBANTRACTS. OESOREED AS RISEELC no& 1MlDLYfNG NORTIEE3RLYOF7FE IM cow STRPOF ASP /MRCamABOlE.NOUna HESTIERY DIME61841 OF RE illfziERY UECFDE TR ACTOF Ufa °ESCHEE4ASPARCIEELAl wawa av:: vodo aguksertvisitV:-.3 ota t - :..ir ;� �31i � v0 S. 1701-700eL AWNED CIIIMFTHINILA AN 02 a"A i PENIATIMIER TUKWILA COMMERCE PARK 12610 -12618 Interurban Avenue South Tukwila, Washington 98168 RREEF Real Estate Investment Managers 1600° Christensen Rod,Saleumm Tobela.Washiegtoo 9848 1110112TH AVE. NE 1 SUITE 500 BEILEVUE. WA 1 98004 t 425.463.2000 1 f 425463200e2 kltivarnyG2oo-n w F- w a JERRYQLAM !$ ARCHITECT PIA F. Heiman ORAV*Ht R Yawea sclo Jane U. 200E Cover Sheet T7.01 I 1 • t I s • Q A Y PJ • CS 0 • 110 —x x— LEGEND EXISTING WALL TO REMAIN. PANEL JOINT IN TILT -UP CONCRETE WALL. EXISTING TO BE REMOVED. NEW DEMISING WALL PER DETAIL 4/A4.01. NEW OFFICEMWREHOUSE WALL PER DETAIL 5NA4.01. NEW RESTROOM WALL PER DETAIL 6/A4.01. INFILL WALL PER DETAIL 10VA4.01. NEW FURRED CONCRETE WALL PER DETAIL 7/A4.01. NEW TYPICAL OFFICE WALL PARTMON PER DETAIL 8/A4.01. NEW TWO HOUR WALL ONALL) PER 4/A5.01. BUILDING GRID UNE DOOR DESIGNATION. SEE DOOR SCHEDULE - SHEET A5.01. DENOTES EXISTING. ROOM N AMEA R DESIGNATION. SEE ROOM SCHEDULE -SHEET A5.01. EXISTING Dock -N1GH DOOR TO REMAIN. EXISTING DRIVE -INN DOOR TO REMAIN. FIRE EXTINGUISHER LOCATION. DATA OUTLET ELECTRICAL OUTLET TELEPHONE OUTLET EXISTING CHAIN LAIC FENCE EXISTING DOWNSPOUT. a • PHASE ONE t SAW CUT EDGE OF EXISTING ASPHALT AND PROVIDE NEW A.C. PAVING N SHADED AREA. MATCH EXISTING PAVEMENT SECTION AND SLOPE TOCana CATCH BASK REMOVE622 SF. E US'HNG LANDSCAPE AREA 4. TNISMEAS NMI BE ADJUSTEDiLEVEIW AS NECESSARY TO 2 PROVIDE FOR MI ADACONFORMING ENTRANCFJEIOT FOR TENANT ONE COORDINATE WORK: WITH CQY TO VERIFY COMPLTANICE. 6. NEW STMDMD PARKING STILL x x —x—x Z x 9.774 SF. (4.T4M18 VERIFY)NEW REPLACEMENTtNIDSCA?E AREA SAWCUF AND REMOVE DOSING AC PAVING N THIS AREA AND RELOCATE PUNT MATERIALS FROM NORTH SIDE OF BUILDING TO THIS LOCATION. It NEW ACCESSIBLE PARKING STALL 13. DOSING ON SITE IRRIGATION SYSTEM TO BE EXTENDED TO SERVE NEW LMOSC,APEAREA MI KTO BE OESIGNMULD N NATURE WITH NECESSARY PERMITS TO BE SECURED BY OESIGNIBULD CONTRACTOR 14. NEW EX1EBDEO CONCRETE CURBING AT THIS LOCATION. x X x -x A OTES D--- PHASE TWO: 7. NEW E OT STAIRS AT DOS DOOR TO MATCH EXRSTNG STAIRS ON SOUTH EXIT COORS (TYPICAL). L PAINT WHITE ON ASPHALT. YRLOW ON CON c MAX) IL CON RI EOS1ING STAMVJW PM(IIG STALL TONEW VAN ACCESSIBLE PARIOLG STALL • PJ PJ r x V FLOOR PLAN SCALE 3/32' = 1'-0' x--ar x- -x PHASE THREE 2. EXTEND DOSING OONCREIE LANDING MD TO CREATE AN ACCESSIBLE ENTRWAC(ESS FOR TENANT THREE REMOVE DOSING 126 SF. LANDSCAPE AREA 3. DOSING 7-07R-0` W/S81 g 3 REMOVE SECTION OF CONCRETE PANEL FROM 341* SILL HMI' DOWN TO FINNISH FLOOR AND INSTALL A UMW ALU INIUM STOREFRONT DOOR AT DISLOCATION. • PJ 11111!! PJ GENERAL KEY NOTES: S DOSING CATCH BASIN LOCATION. 12. FOUIDATIOYFOOTNG(EDSTNG). 15. ROOF ORAN LIES TO BE REROUTED NECESSARY TO CONIMNE TO PROVIDE FORSHRT FLOW OF ROOF STORM WATER ACROSS PARING AREA TO CATCH BASKS. PJ • 1 4 PJ i l - x-- -f • !I 7 - � • c :�. c; ; ;C % - CITYCFTHIMAIA PERIMICBOER TUKWILA COMMERCE PARK 12610 -12618 Intenvban Avenue South Tukwila, Washington 98168 701-022, Real Fstate Investment Managers 16000 Christmas Reek Sake 1m DIM%Washiogon 98188 1110112TH AVE NE) SURE 500 BELLEVUE, WA 1 96004 1425.4632000 t f 425.4632002 MwvanyG2.00m F- w F- w a f Jam Gum LEE Amami o Ra t&aps7adtb/atdr Os obaiswt gar be - traor lbw sSp ire ors mote's _ Wine= SiessegGIAIS•••••• '61 DI1TE DESCtiP4101N .17.02 Oeetr Rofeion 2 0•27:02 CIy Revision 3 [10.07.02 Omer Revisions -Paled Please 02 -1960 PR F. Harems O RALN& IL Yaounde June 43. 2002 I Floor Plan A2.01 I RREEF 1 (l� W 0 z W CE 0 w O O N z O O z � w CO o O� 0 C/) c x CD w W W Z O 2 z w < O • 1 G • D 0 C W C) w No-.9Z r� .. ' :;• LJ : . ; - L.) ; •., 1.. • .. • 119 ' • 1 11o t� I I ` t•i/ ._ _... -. — .v- LJ r a ; W 5: z O W J W • r.... ••: •.:. , • V. i• 11o•Ioz I. 11V ._./.4040.w _••■._ <C r 7 ;t1 ., •• -: • .. 11 ... •. 1• 1• , Y A- 011._.._■•=.......r. • ft 1 I .._ •I./ _.• _. • ._._......... "._. .._..___�,;��. • • W _ z 0 W J W z O •' I". ro •._..r__.-- _- __....._. - - -- 110 'OE' 1 I. ti . • • • • • • • 1 .I F its • • V • • • • A • 1 ... . I I • t L (l� W 0 z W CE 0 w O O N z O O z � w CO o O� 0 C/) c x CD w W W Z O 2 z w < O • 1 G • D 0 C W C) w No-.9Z r� .. ' :;• LJ : . ; - L.) ; •., 1.. • .. • 119 ' • 1 11o t� I I ` t•i/ ._ _... -. — .v- LJ r a ; W 5: z O W J W • r.... ••: •.:. , • V. i• 11o•Ioz I. 11V ._./.4040.w _••■._ <C r 7 ;t1 ., •• -: • .. 11 ... •. 1• 1• , Y A- 011._.._■•=.......r. • ft 1 I .._ •I./ _.• _. • ._._......... "._. .._..___�,;��. • • W _ z 0 W J W z O •' I". ro •._..r__.-- _- __....._. - - -- 110 'OE' 1 I. ti . • • • • • • • 1 .I F its • • V • • • • A • BRACING DETAIL GENERAL CONFIGURATION BEAM CONNECTION SEC. A -A HORIZONTAL & DIAGONAL BRACING 3/8 . '0 BOLTS TYP, 4 e l:No====e SEC. B -B 40. N; 4 : CO at j t =.07" f. 96" • 0 • d 9 1 17i 42" 4 7/16'0 RIVET ASTM A354 -79 • r 1 FRONT VIEW SIDE VIEW LB311 • _ lot 1B BASE PLATE DETAIL t =3/8 iO i 6" 7 3/4" 3/16 V (2) -1/2 "0 ANCHOR BOLTS PER BASE PLATE 3 1/2" EMB.. (SEE NOTE NO. 4) TYP n 3.4x2.18x3/16' FORMED CHANNEL • _ N 3.42" :18" f 0 9c4 OOz: ROW SPACER MEAL 1 - DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COIAPUANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2003 EDITION 2 -STEEL FOR ALL SHAPES FY =50 KSI. ASTM A570 -85 GR.50 (EXCEPT AS NOTED) 3 -ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR '/777 (E70)0L ELECTRODES) 4 -ALL ANCHORS HILTI KWIK BOLT 3 ESR -1385 OR APPROVED EQUAL (NO SPECIAL INSPECTION REQUIRED) 5- CONCRETE SLAB 5" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6- STORAGE RACK CAPACITY 3200 // LEVEL 7-ALL RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD OF 3200 #/ LEVEL 8- STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1 fr IN 10' -0" OF HEIGHT Exams 12 -25-07 • DATE 1 -- U • .,•,' • • • a i • - ...• s- ►� - ' .l -t. • .% REVISION CK DESIGN AND ENGINEERING 412 WEST BROADWAY SUITE • CA. 91204 PROJECE SHOW POINT LOGISTICS 126x0 IVTERUReAN AVE. SC.. BLDG. "D" #100. TU KWILA , WA. 98138 STORAGE RACK DETAILS ..SOB NO. !SHEET NO. RD -11587 I 1 OF 1 I a