Loading...
HomeMy WebLinkAboutPermit D07-017 - GAMES WORKSHOP - REMODELGAMES WORKSHOP 16874 SOUTHCENTER PY D07 -017 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: 2623049129 16874 SOUTHCENTER PT TUKW GAMES WORKSHOP 16874 SOUTHCENTER PY , TUKWILA WA PARKWAY SQUARE C/O ROSEN PROPERTIES , PO BOX 5003 98009 Contact Person: Name: DEAN L BARTH Address: PO BOX 77724 , SEATTLE WA 98177 Phone: 206 533 -8402 Contractor: Name: IDEAL INTERIORS INC Address: PO BOX 77724 , SEATTLE WA 98177 Phone: 206 - 361 -8884 Contractor License No: IDEALIIO26DC DESCRIPTION OF WORK: REMODEL OF EXISTING RETAIL SPACE Value of Construction: $20,000.00 Type of Fire Protection: SPRINKLERS Type of Construction: doc: IBC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 02/17/2008 Fees Collected: International Building Code Edition: Occupancy per IBC: Steven M. Mullet, Mayor Steve Lancaster, Director D07 -017 02/27/2007 08/26/2007 $661.50 2003 0019 D07 -017 Printed: 02 -27 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us Permit Number: D07 -017 Issue Date: 02/27/2007 Permit Expires On: 08/26/2007 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature I hereby certify that I have read and governing this work will be compli N A °1 4 494 The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the • erformance of work. I am authorized to sign and obtain this development permit. Signature: Date: 2°77. 7 Date: V` Steven M. Mullet, Mayor Steve Lancaster, Director s permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. Print Name: De L • fJc 44 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D07 -017 Printed: 02 -27 -2007 Parcel No.: 2623049129 Address: Suite No: Tenant: doc: Cond -10/06 GAMES WORKSHOP 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16874 SOUTHCENTER PY TUICW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -017 ISSUED 01/17 /2007 02/27/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until fmal inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of'Iukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 13: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 14: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. D07 -017 Printed: 02 -27 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 16: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 17: ** *FIRE DEPARTMENT COND1TiONS * ** 18: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 19: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 21: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 22: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 23: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4 -4) 24: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk doc: Cond -10/06 D07 -017 Printed: 02 -27 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 32: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D07 -017 Printed: 02 -27 -2007 Signature: Print Name: � L • 64 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 6 7' D07 - 017 Printed: 02 -27 -2007 bh CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cltukwila.wa.us Building Permit No. Mechanical Permit No. vant 'b11- Plumbing/Gas Permit No. WA- 1) lc Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 4 King Co Assessor's Tax No.: 2 .Ll 7, ' " L t2-1 Site Address: 1(.071 4 ` C DI Y l � Suite Number: Floor: Tenant Name: C a i Y \ e S ( O . ( \ ( ) n - ^ New Tenant: R. Yes El .. No Property Owners Name:Eve 5�10��tf1C� Ct ec c o t (.tA0..... �� t J r.. Mailing Address: J Name: �L ■ Mailing Address: ?O - 6CD X - 7 - 7-04 E -Mail Address: ( Ve.rtors_t UAO . COkey‘ Contact Person: a Jean E -Mail Address: idea _ t n-'ex' tors_ t ` oc o , co (•■ Contractor Registration Number: ZEE A L ==TIC- Contact Person: E -Mail Address: City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone:oDO(o F 5e� � (i) R$ "? - 7 City State Zip Fax Number: aO(n S 84 - 7°l GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: =cl ew\ In +(toe -_ S I (\C Mailing Address: PO - 77 - 1 a4 5 rMe Ui r ciX I T 1 -O°Ic.).1 City State Zip Day Telephone: aao Fax Number: a cx0 `J33 S Expiration Date: a 117108 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip State City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:Upplications\Porms- Applications On Line 3 -21X16 - Permit Application. doe Revised: 9 -2006 Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ ate. O °p . c. Existing Building Valuation: $ Scope of Work (please provide detailed information). Aeloloct -'-'t D .Q 1C I--f4 •��« Will there be new rack storage? ❑ Yes �No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Er Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Er No If "yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Upplications\Fonns- Applications On LineU -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor /Oleg n /4 2 Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ ate. O °p . c. Existing Building Valuation: $ Scope of Work (please provide detailed information). Aeloloct -'-'t D .Q 1C I--f4 •��« Will there be new rack storage? ❑ Yes �No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Er Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Er No If "yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Upplications\Fonns- Applications On LineU -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) g Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks ( Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent I Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: American mt.C,hI(\IC&t Co r p Mailing Address: v . . - : ' , 1 X. 11N MD(1 (i) a-7 ca City State Zip Contact Person: J . e-4 'R Q \ 'n4.C° \ Day Telephone: & c' '4(i 7 -(4O 7 E -Mail Address: J f C.tr X ek@Gt'c ' CCA Y eckrAl►tCGJCOr9 .CO(Y1 Fax Number: LIDS tT9- y 0 - 7 C Contractor Registration Number: A eil E R1-ImCA6 - 7 1 li Expiration Date: 118I09 Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Ft cn6\nS de1(NY:Ay - o t )4 LV■ ) Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\Applications\Forms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 Print Name: BUILDING OWNS OR ZED AGENT: Signature: Mailing Address: Pa 4o x 777 ?`? Q:\ Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bit PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone: S ea e GU ,4- City Date: I' 1 ' 7 (31 State Zip Date Application Accepted: fi II n— t Date Application Expires: 4, Staff Initials: Page 6 of 6 Doc: RECSETS -06 RECEIPT NO: R07 -00070 Initials: JEM User ID: 1165 Payee: IDEAL INTERIORS, INC. SET ID: S000000669 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -017 661.50 PG07 -015 118.00 TOTAL: 779.50 TRANSACTION LIST: Type Method Description Payment Check 8040 779.50 TOTAL: 779.50 ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www ci. tukwila. wa. us BUILDING - NONRES PLAN CHECK - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT Payment Date: 01/17 /2007 Total Payment: 779.50 Amount Account Code Current Pmts 000/322.100 398.18 000/345.830 258.82 000/322.100 118.00 000/386.904 4.50 TOTAL: 779.50 378. 01/17 '7 16 TOTAL Project: a Type of Inspection: Addres /60 s f)* ate Called: Special Instructions: p Wanted;,, n, 07 e Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTIIN NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 OMMENTS: ( 74/„. Approved per applicable codes. El Corrections required prior to approval. Date: 17...„.07 ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Projj cct: "' //one S 410Y,1 44)/1 Type of Inspection: / f 7-170 7' 1 / Address: , 8 7 " _Ca /4,44.J 'v / Date Called: 7 Special Instructions: Date Wanted: . - 9_5 O a. .rrr Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. 0Corrections required prior to approval. CO M MENTS: INSPECTION RECORD Retain a copy with permit • ' . r� / / V /� rat $58.0 I F 3' EQUIRED. Prior to inspection, fee must be vd., Suite 100. Call to sechedule reinspection. Inspecto paid at 6300 Southcenter Date: 206)431 -3 7 Receipt No.: Date: Project: e 6 �,'c5 G!)''k..,Sd70, /o Type of Inspection: / Fi 4) (.' / j Addre " ! 6 '5_7 't/ , 0,1 (7,,,,u*,, /)(7 Date Called: Special Instructions: Date Wanted: 5 — / " 0 °) / P.m. Requester: Phone No: „2O6 -- ',=/ S'- 5' y0 ? INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 .. ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit D © 7- O ( 7 Jz COMMENTS: 1s u.17 /- . 3 X r,yli 4 . - r ifre Corrections required prior to approval. El $58. 1O REINSPECTIOfdFEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: -s P, S i Type of Inspection: 4 10 9 .. 0" p e Address: /4,e ?� ,CC " e4 Date Called: Special Instructions: s: Date Wanted: " a.m. d '"p ._..s.�„ ' �y Requester: Phone No: ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: /1(4,7 $58.0d INSPECTIOWFEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: L.5•1 G WOvks Ivor) Type of Inspection: P, I Address: Suite #: Ad 7 S L P y Contact Person: Deq ( Al Special Instructions: Phone No.: :) b - 9`ll ` /off Needs Shift Inspection: y Sprinklers: `( Fire Alarm: Al Hood & Duct: N Monitor: Pre -Fire: Permits: nl Occupancy Type: M INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Do -or PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 COMMENTS: 1- C F'- , c, J 0 1t Approved per applicable codes. Inspector: S/ Date: 3-0-o - 7 Hrs.: 1 - 1 Corrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: GA nits wok K.5 tto P Type of Inspection: -.Pg /M / LLB. Address: a $ 91/ s, (' Suite #: ./ Contact Person: 0& ift-/ Special Instructions: . Phone No.: ?C) ,- / 0(102_ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 `pproved per applicable codes. COMMENTS: �P� INK LL - ok Inspector: i /2 Date: jiy / 7 rs: / .. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS ri Corrections required prior to approval.. T.F.D. Form F.P. 113 Project Info Project Address Games Workshop Date 1/3/2007 Parkway Square For Building Department Use Tukwila, WA Applicant Name: 4 - Fill out this line on PRJ -SUM Applicant Address: 5 - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM • 2004 Seattle Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM Note automatic daylightinq. occupancy sensor. and other control requirements of Section 1513. as applicable. FILE COM Prrr!t No. � \SU11:'iil %.• KS L 1. Sir. Revised May 2005 L EXPIRES 1/- s-,0 7 .J REVIEWED FOR CODE COMPLIANCE FEB 2 6 2001 C1 • f 11a wile BUILDING DIVISION CITY RECEIVED JAN 2 3 2001 PERMITCENTER Pgq Project Info Project Address Games Workshop Date 1/3/2007 Parkway Square For Building Department Use Tukwila, WA Applicant Name: 4 - Fill out this line on PRJ -SUM Applicant Address: • 5 - Fill out thi line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM 2576.5 Project Description ❑ New Building ❑ Addition 4 Alteration U Bldg > 5000sf, auto shutoff req. ❑ Plans Included requirements. Refer to SEC Section 1513 for controls and commissioning Compliance Option O Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) v _ v Occupancy Description Allowed Watts per ft Area in ft Allowed x Area Sales Sales 3.06 842.0 2576.5 Stock Stock 0.50 184.0 92.0 Toilet Toilet 0.80 42.0 33.6 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2702.1 p Location Number of Watts/ Watts (floor /room no.) Fixture Description Fixtures Fixture Proposed Sales 2x4 Recessed Fluorescent 18 128.0 2304.0 Stock 48" Strip Fluorescent 3 64.0 192.0 Toilet Light /Fan Combo 1 75.0 75.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2571.0 Allowed Watts Area in ft Allowed Watts Location Description per ft or per If (or If for perimeter) x ft (or x If) Covered Parking 0.2 W /ft Note: 2004 SEC does not allow trading between covered parking and ext. ltg. Total Allowed Covered Parking Watts Open Parking 0.15 W /ft Outdoor Areas 0.15 W /ft • Bldg. (by facade) 0.15 W /ft Bldg. (by perim) 7.5 W/If 1. Choose either the facade area or the perimeter method, but not both) Total Allowed Bldg. Exterior Watts p g g Number of Watts/ Watts Location Fixture Description Fixtures Fixture Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Maximum Allowed Lighting Wattage (Interior 2004 Seattle Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM Note automatic day ighting, occupancy sensor, and other control requirements of Section 1513, as applicable. Revised May 2005 Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. Pro osed Lighting Wattage (Interior). List all fixtures. For exemp lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior use mtgr listed maximum input wattage. I-or hxtures with hard -wtrea aanastSOnly, Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. Allowed Watts Area in ft Allowed Watts Location Description per ft or per If (or If for perimeter) x ft (or x If) Covered Parking 0.2 W /ft Note: 2004 SEC does not allow trading between covered parking and ext. ltg. Total Allowed Covered Parking Watts Open Parking 0.15 W /ft Outdoor Areas 0.15 W /ft • Bldg. (by facade) 0.15 W /ft Bldg. (by perim) 7.5 W/If 1. Choose either the facade area or the perimeter method, but not both) Total Allowed Bldg. Exterior Watts p g g Number of Watts/ Watts Location Fixture Description Fixtures Fixture Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Maximum Allowed Lighting Wattage (Interior 2004 Seattle Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM Note automatic day ighting, occupancy sensor, and other control requirements of Section 1513, as applicable. Revised May 2005 Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. Pro osed Lighting Wattage (Interior). List all fixtures. For exemp lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior use mtgr listed maximum input wattage. I-or hxtures with hard -wtrea aanastSOnly, Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. p g g Number of Watts/ Watts Location Fixture Description Fixtures Fixture Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Maximum Allowed Lighting Wattage (Interior 2004 Seattle Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM Note automatic day ighting, occupancy sensor, and other control requirements of Section 1513, as applicable. Revised May 2005 Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. Pro osed Lighting Wattage (Interior). List all fixtures. For exemp lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior use mtgr listed maximum input wattage. I-or hxtures with hard -wtrea aanastSOnly, Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. Maximum Allowed Lighting Wattage (Interior 2004 Seattle Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM Note automatic day ighting, occupancy sensor, and other control requirements of Section 1513, as applicable. Revised May 2005 Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. Pro osed Lighting Wattage (Interior). List all fixtures. For exemp lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior use mtgr listed maximum input wattage. I-or hxtures with hard -wtrea aanastSOnly, Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. Use LPA (W /&) Use' LPA (W /ft Painting, welding, carpentry, machine shops 2.30 Medical offices, clinics 1.20 Barber shops, beauty shops 2.00 Atria (atriums) 1.00 Hotel banquet/conference/exhibition hall" 2.00 Assembly spaces ° , auditoriums, gymnasia theaters 1.00 Laboratories (see also office and other appropriate categories) 1.80 Group R -1 and R -2 common areas 1.00 Aircraft repair hangars 1.50 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.00 Cafeterias, fast food establishments 1.50 Police and fire stations 1.00 Factories, workshops, handling areas 1.50 Process plants 1.00 Gas stations, auto repair shops 1.50 Restaurants/bars 1.00 Institutions 1.50 Locker and /or shower facilities 0.80 Libraries 1.50 Warehouses storage areas 0.50 Nursing homes and hotel/motel guest rooms 1.50 Aircraft storage hangars 0.40 Retail retail banking 1.50 Parking garages See Section 1532 Wholesale stores (pallet rack shelving) 1.50 Plans Submitted for Common Areas Only' Mall concourses 1.40 Main floor building lobbies (except mall concourses) 1.20 School buildings (Group E occupancy only, school classrooms, day care centers (( 4-35 )) 1.20 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 - Laundries 1.20 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Lighting Check if all fixtures are ballasted and at least 95 %* of fixtures are either: Note: If occupancy type is "Other" and fixture Fixtures: answer is checked, the number of fixtures in (Section 1. Fluorescent fixtures which a) are non - lensed. b) have 1 or 2 two lamps c) have the space is not limited by Code. Clearly 1521) 5-60 watt T -1, T -2, T-4, T -5, T-6, T -8 lamps. d) have hard -wired electronic indicate these spaces on plans. If not dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified, do LPA Calculations. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts * - Exit and LED lights can be excluded from count if < 5 watts /fixture. 2004 Seattle Nonresidential Energy Code Compliance Form Lighting Summary (back) LTG -SUM Note automatic daylighting, occupancy sensor, and other control requirements of Section 1513, as applicable. TABLE 15 -1 UNIT LIGHTING POWER ALLOWANCE (LPA Revised May 2005 Footnotes For Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Lighting Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) The watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Lighting Power Allowance for assembly. 5) The watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) See Section 1532 for exterior lighting. 7) For conference rooms and offices less than 150 ft with full- height partitions, a Unit Lighting Power Allowance of 1.20 w /ft may be used. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.00 W /ft 9) For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.60 W /ft provided that there is a manual dimmer or at least two additional steps of lighting control in addition to off. 10) Display window illumination installed within 2 feet of the window, provided that the lighting is fitted with LED. tungsten halogen, fluorescent or high intensity discharge lamps and that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 W /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a. located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall), b. adjustable in both the horizontal and vertical axes ((( )) fluorescent and other fixtures with two points of track attachment are acceptable with vertical axis only), c. fitted with LED, tungsten halogen, fluorescent or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 12) Medical and clinical offices include those facilities which, although not providing overnight patient care, do provide medical, dental, or psychological examination and treatment. These spaces include, but are not limited to, laboratories and treatment centers. Lighting Permit Plans Checklist Note automatic daylighting, occupancy sensor, and LTG -CHK other control requirements of Section 1513, as applicable. Revised May 2005 Project Address Games Workshop !Date 1/3/2007 The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 2004 Seattle Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations no vertical glazing Indicate vertical glazing on plans . no overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w/backup Indicate location no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 1513.7 Commissioning Indicate requirements for lighting controls commissioning yes Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture no I 1437 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency If "no" is circled for any question, provide explanation: 2004 Seattle Nonresidential Energy Code Compliance Form Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls, when provided in addition to manual controls, need not be accessible to the users and may be centralized in a remote location. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: Lighting in ((A)) all daylighted zones, as defined in Chapter 2 (see Exhibits 1513.3a and 1513.3b), both under overhead glazing and adjacent to vertical glazing, shall be provided with controls that comply with Sections 1513.3.1 and 1513.3.2 ((' of general - lighting)). I. I control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. n orth, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. J513.3.2 Automatic Control: Daylight zones shall have controls which automatically reduce lighting power in response to available daylight by either: g a combination of dimming ballasts and daylight- sensing automatic controls. which are capable of dimming the lights continuously. or b. a combination of stepped switching and daylight- sensing automatic controls, which are capable of incrementally reducing the light level in steps automatically and turning the lights off automatically. j.Single -lamp luminaire systems shall have three levels of automatic control: all lamps on. approximately half of the luminaires turned off in a relatively uniform pattern, and then all of the luminaires off. As an alternate, where the daylight zone contains two rows of luminaires and they are parallel to a window, three levels of automatic control may also be achieved by having both rows on the row closest to the window off and the other row on. and both rows off. For rooms, such as small offices, which contain only a single one -lamp luminaire. it is acceptable for the daylighting control system to automatically switch off the entire luminaire. jj. Two-lamp luminaires shall have three levels of automatic control: both lamps on, one lamp on and one lamp off, and both lamps off. As an alternate. where the daylight zone contains two rows of luminaires and they are parallel to a window, three levels of automatic control may also be achieved by having both rows on. the row closest to the window off and the other row on. and both rows off. For rooms. such as small offices. which contain only a single two-lamp luminaire. it is acceptable for the daylighting control system to automatically switch off the entire luminaire rather than switching off one lamp, then both lamps. Three -lamp luminaires shall have four levels of automatic control: all three lamps on. two lamps on and one lamp off, one lamp on and two lamps off, and all three lamps off. iv. For other multi -lamp luminaries with four or more lamps, the number of required incremental steps shall be equal to one plus the number of lamps in the luminaire Any switching devices installed to override the automatic daylighting control shall comply with the criteria in Section 1513.6.2a -e. 2004 Seattle Nonresidential Energy Code Compliance Form Lighting Permit Plans Checklist LTG -CHK Note automatic daylighting, occupancy sensor, and other control requirements of Section 1513, as applicable. Revised May 2005 nt .I whi h EXCEPTIONS: 1. The following are exempt from the requirements for automatic daylighting controls in Section 1513.3.2: a. retail spaces adjacent to vertical glazing (retail spaces under overhead glazing are not exempt), b. lighting exempted by Section 1512. and c. display, exhibition, and specialty lighting complying with Section 1513.4. 2 The following spaces are exempt from the requirements for automatic daylighting controls in Section 1513.3.2 provided that they have occupancy sensor controls that comply with Section 1513.6.1: a. small spaces in the daylight zone that are normally unoccupied such as a storage room with a window, or restrooms), b. rooms less than 300 square feet. and c conference rooms 300 square feet and larger that have a lighting control system with at least four scene options. 3. HID lamps with automatic controls that are capable of reducing the power consumption by at least 50% in lieu of continuous dimming controls in 1513.3.2. 4. HID lamps 150 watts or less are exempt from the dimming requirements in 1513.3.2. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut - off Controls, Exterior: Exterior lighting ((net photeeell-er)) including signs, shall be capable of being automatically switched off during daylight hours and non -use nighttime hours by either a combination of timer and photocell, or a timer with astronomic control. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. 1513.6 Automatic Shut - Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is iated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over- ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. Lighting Permit Plans Checklist LTG -CHK Note automatic daylighting, occupancy sensor, and other control requirements of Section 1513, as applicable. Revised May 2005 Skylight A Width H = Floor to ceiling height 45 Degrees Full height I H partition t - - -J Outline of skylight above Daylighted area 2004 Seattle Nonresidential Energy Code Compliance Form Daylight area beneath corwentional skylight Daylighted area includes floor d atrium and the top floor next to the atrium Exhibit 1513.3a DAYLIGHTED ZONE: 1. Under overhead glazing: the area under overhead glazing whose horizontal dimension, in each direction, is equal to the overhead glazing dimension In that direction plus either the floor to ceiling height or the dimension to a ceiling height opaque partition, or one -half the distance to adjacent overhead or vertical glazing, whichever is least. Daylighted area cut short by full height partition 15 Feet Daylighted Area Daylighted H Area Non - DayGghted dayrghted Area area Daylighted area extends 2 ft (610mm) to side or to nearest wall. V H • Exhibit 1513.3.b DAYLIGHTED ZONE: 2. At vertical glazing: the area adjacent to vertical glazing which receives daylighting from the glazing. For purposes of this definition and unless more detailed daylighting analysis is provided, the daylighting zone depth is assumed to extend into the space a distance of 15 feet or to the nearest ceiling height opaque partition, whichever is less. the daylighting zone width is assumed to be the width of the window plus either two feet on each side (the distance to an opaque partition) or one -half the distance to adjacent overhead or vertical glazing, whichever is least. Games Workshop 6711 Baymeadow Dr. Glen Burnie, MD 21060 410- 590 -1400 To whom it may concern, It has recently come to my attention that in our description of use for our retail space the wording of a gaming area was used. I would like to clarify that Games Workshop is not a gathering place for people to just come in and play games at their will. The staff in the Games Workshop stores will conduct introductory games to demonstrate to the customers how the games are played. We do sell several different games such as Lord of the Rings etc. that Games Workshop has invented and we display them on the tables shown in the layout of the new retail store drawings. Please note that these fifteen to twenty minute demonstration games are conducted by our staff and can only be played with two people per a table since our games are a one on one design. The staff will demonstrate how the game is played and then initiate a sale of that game if the customer is interested. Our games are not well known therefore it requires that we demonstrate how to play to our customers. We do have a small clientele who have been playing our games and do not require any demo game; they strictly come in to purchase our latest gaming figures. I apologize for any misunderstanding in regards to the use of the space. Thank you, John Beauchamp Director of Facilities & Construction Games Workshop 410 -689 -2441 Office 443 - 540 -0835 Cell 410 -689 -2440 Fax CITRECEIVED VILA FEB 0) 2flr 7 DI4 PERMITCENTER 2/6/2007 CORRECTION LTR# 6711 Baymeadow Drive, Glen Burnie, Maryland 21060 -6401 Telephone: 410 5901400 Fax: 410 590 1444 http : / /www.games-workshop.com January 31, 2007 Dean L. Barth PO Box 77724 Seattle WA 98177 RE: CORRECTION LETTER #1 Development Permit Application Number D07 -017 Games Workshop —16874 Southcenter Py Dear Mr. Barth, This letter is to inform you of corrections that must be addressed before your development penmit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Fire Department. At this time the Building, Planning, and Public Works Departments have no comments. Fire Department: Alan Metzler, at 206 575 -4407, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerel 6/A0 arsha chnician encl File No. D07 -017 City of Tukwila P:Vennifer\Correction Letters \2007\D07 -017 Correction Ltr #1.DOC jem Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 \s FIRE DEPARTMENT REVIEW COMMENTS Project Name: Games Workshop 16874 Southcenter Py Permit File No.: 007 -017 Date: January 25, 2007 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575 -4407 1. Provide a detailed description of the use of the "gaming area" and the use of the six tables in the area. ACTIVITY NUMBER: D07 -017 DATE: 02 -07 -07 PROJECT NAME: GAMES WORKSHOP SITE ADDRESS: 16874 SOUTHCENTER PY Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY �. PLAN REVIEW /ROUTING SLIP t2.0.01- ❑ Fire Prevention Planning Division ❑ Structural Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ DUE DATE: 02-08-07 Not Applicable ❑ No further Review Required DATE: DATE: DUE DATE: 03-08-07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: � PERMIT COORD COP& PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -017 DATE: 01 -23 -07 PROJECT NAME: GAMES WORKSHOP SITE ADDRESS: 16874 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: �IIdirt /I E it Public Works t.. I -'D Fire revention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete E6 Incomplete ❑ Comments: 146' AIL I- 26'D1g P anning Division Permit Coordinator DUE DATE: 01-25-07 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: DUE DATE: 02 -22 -07 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments)I Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: oI Departments issued corrections: Documents/routing slip.doc 2 -28 -02 Bldg ❑ FireX1 Ping ❑ PW ❑ Staff Initials: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: a 1'40 7 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Games Workshop 16874 Southcenter Py tin Rev- -'In Received at the City of Tukwila Permit Center ee ntteer by: Entered in Permits Plus on � V'l b lapplicationslforms- applications on line\revision submittal Created: 8 -13 -2004 Revised: A l I A 1_41 A A A • Steven M Mullet, Mayor Steve Lancaster, Director Plan Check/Permit Number: RECErvED CITY OP TuKwi" FEB 0 7 2007 P ER ''1'7 Cc A; r`;, Phone Number:cDOG °Mq — $yd — A Summary of Revision: Cy ) np 1 e OTC' I l° i .ice ry, ( ckmer Wort 1rl CJ.1C \ el 1n15 1 and cla�r‘ l ` e . use (i d `` mi � ow , The Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision License Information License IDEALIIO26DC Licensee Name IDEAL INTERIORS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601853977 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 77724 Address 2 City SEATTLE County KING State WA Zip 981770724 Phone 2065338402 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/3/1998 Expiration Date 2/17 /2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BARTH, DEAN 01/01/1980 BARTH, SHERYL 01/01/1980 Look Up a Contractor, Electric ;an or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date COLONIAL AM CAS & SURETY Until https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= IDEALIIO26DC 02/27/2007 RESPONSIB1LIlY SCHEDULE a) THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE FOR ACCURACY PRIOR TO BEEEMIIN6 CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO TENANT CONSTRUCTION PRO.ECT MANAGER. , , ' . ". % 40 : • 1= TENANT . • GG- GENERAL CONTRACTOR I DIVISION 01000 - GENERAL P 1 E PPPIIDVDVA 10115TALTEP, E =EXORRO, FR•PATCH I REPAIR. R.RELOCATE 2 BUILDING PERMIT GG 6C EARTH Macs SEAS 6.G. TO PAY FEES 3 CLEAN -UP, FINAL CLEANING GG Slap -i, WirI III • TOILET ROOM 4 DEMOLITION GG ARMS 5Nq{5 5 NEUTRAL PIERS AND MALL BULKHEAD FGI 6E WA 6 OVER PERMITS, FEES, INSURANCE Si RETAIL AND NON SALES AREA vNYL EASE 4' HIGH VINYL COVE BASE - I TEMPORARY BARRICADES 0 18 7::::x33 cu::4 ag DDiv:::: :::. t:07::: rFtsr;;;a1S LY.7 '. •- ;'- , t. r�eyt ve a nett, ;:.; s_...� L �� �/ Include ! •ev, fzes. VERIFY MALL REQUIREMENTS 8 TRASH REMOVAL/DISPOSAL AND DUMP5TERS VERIFY MALL REQUIREMENTS, G.G. TO OF ALL BOXESIK.RATE✓TRASH OF ALL TENANT SUPPLIED AND INSTALLED ITEMS, LNG.. DISPLAY FIXTURES AND HARDWARE q DIVISION 02000 -SITE WORK P 1 E P•PIOOVDED kl6TMLED E•DUSI PRE/PATCH I WE PAR R•RE1.OGAl IO NO WORK UNDER MS SECTION WALL FUSS RETAIL SALES /PEA fi'8iE INDICATED 5LAT1iALL 11 DIVISION 03000 -CONCRETE WOES P 1 E P•FFOOVDED, bletAL .ED. MAMMY FR•PATOI I IOEPAIR R•RELOCATE 12 CONCRETE 51AB • GC.. TO PREPARE FOR NEW FLOOR FINISHES 13 CONCRETE TRENCHING 4 REPAIR GG GG Ca AS REQUIRED 14 6sAlll 4G AREA MAILS NV RETAIL AREA ABOVE SLATMALL MERE NDC.ATN3D PAW) ORANGE - 'C.EYE7air SteRMA NILLIN"G 15 DMSiON 04000 - MASONRY 1' 1 E P•PPDVIDID. IsI1a5TALLIA E =DOSTR15. FR•PATG N I NEPMP. R•REICCATE 16 NO WORK UNDER THIS SECTION BLACK - 'TRICORN CLACK' K' SHEMIN Sri 6?S8 PROVIDE PRIMER AND 2 FINISH COATS, GLOW. FINISH ON ALL TRR4 Il DIVISION 05000 - METALS _ la P I E P•FROVIVE ) PwPAw1 a iEPAR R.00ATE DEMISING PARTITION FRAMING 94-6532 PROVIDE RECOMMI34DED PRIMER AND 2 F S H COATS, SATi 4 FR`45I1 ON ALL MALLS • 19 INTERIOR PARTITIONS, FRAMING GG 6G SHEMIN 91-830840C 2 • STOREFRONT FRAMING (an • 21 STOREFRONT SOFFIT FRAMING WA 2 • DIVISION 06000 - WOOD AND PLASTICS r I E PPPIOOWDED. I616TMLEP.&E M S. FRs?ATGH 4 1t6PARR.PAOC,ATE BLOCKING LION GONEUST1eLE LWEER 1 PL.YY•) GG 6G AS DETAILED (NON- GOMBU5T1BLF,) 2 • ROUGH CARPENTRY GC,GC DMSEON 01000 -THERMAL 4 MOISTURE PROTECTION P 1 E POi00V>Ok'D.1•NsT/1LLED E PR•PATCH a REPAIR RrRlLOCATE 2 - AIR AND VAPOR BARRIER / STOREFRONT N/A 27 DMSiON 08000 - DOORS I VIND01 P I E P.PPOVDED hlLSTML87. E•EXtSM <S FR•PATGH I REPAIR. ft4113.0GATE 2 % STOREFRONT FRAMING AND ENTRY DOORS • 29 STOREFRONT DISPLAY WINDOP6 • • STOREFRONT LOCK GORES ADD KEYS 6G GC • CHECK FOR PROPER OPERATION 31 INTERIOR DOORS, FRAMES, HARDWARE GG 6G SEE DOOR SCHEDULE 3 REAR SERVICE DOOR, t FRAME WA 33 REAR SERVICE DOOR EXIT DEVICE SYSTEM WA • REAR SERVICE DOOR MISG. HARDWARE ' N/A 35 MIRRORS (TOILET ROOM) GC 6G • TO BE RELOCATED • DIVISiONN 0 - FINISHES P I E P•Fraotnoen hI6T/V. LED. MEMOS FRtsPATGH a RPM CURROCATE 31 CEILING WSPB4SION SYSTEMS • SEE REFLECTED PLAN % AGOESTICAL TILES (SALES) • SEE REFLECTED PLAN 39 AGOUSTIGAL TILES NON SALES) • SEE REFLECTED PLAN • • GYPSUM WALL BOARD (WE145116 PARTITIONS) • PATCH AND REPAIR ONLY, READY FOR PAINT 41 GYPrI4 MALL BOARD (INTERIOR PARTITIONS) GC GG SEE CONSTRUCTION PLAN 4 GYPSUM WALL BOARD (STOREFRONT SOFFIT) • 4 ' GYPSUM WALL BOARD (COLUMN E31GLOS11RE5) WA SLATWALL Hu H INSERTS AND TRIM T GG 45 VINYL TILE FLOORING T GG • - VINYL BASE GC GG , " 41 REDUCER STRIPS, ADHESIVE, ETC. GG 6G - ' r • % FLOOR PREP I PROTECTION GG GC 4q PAINTING, FINISHING GC `G • VINYL GRAPHIC WALL COVERING T GG 51 52 53 54 - 55 56 DIVISION 10000 - SPECIALTIES P 1 E P•FiOOVIDED.1•WAILER INNS,, PRUPATOI • REPAIR. R•RELOGAT1: 57 STOREFRONT RUMINATED 9614 T T SUPPLIED AND INSTALLED BY SIGN CONTRACTOR UNDER SEPARATE PERMIT 58 ACCESSIBILITY S1GNAGE GG GC • AS REGLIRED 59 TOILET AGCES50RIE5 GC GG • SEE TOILET ROOM SHEET • • FIRE EXTINGUISHERS GC GC 61 6 , DMSSIO N 11000 - EQUIPMENT P 1 E P•PROVDEOPISTAL LIA EgERISTRISs. PRsPA1011 a WAR R•RELOCAiE 6 NO WORK UNDER THIS SECTION • ' DIVISION 12000 -FURNISHINGS P I E P•PROVIDlR hl6TAU ED. E•E)a6Tla5L PR•PAT°. a REPAIR R•Ra,OGATE 65 SLATWALL T 6G - - G SHMA' T 6G POWER RIPPLY 4 PHONE BY 6L. 67 INTERIOR MILLWORK (CA&EETS, DISPLAY UNITS ETC) T ,GG • % LOOSE FIXTURES, WOOD AND METAL T T 69 MERCHANDISE WALL HARDWARE T T • MISCB.LANEous STORE EMIPM134T _ T T ^ 11 DM I Z 9011 13000 - SPECIAL CONST TION P I E PaPROVDEID, kNST/It1ER EsM57llrap FR•PATr.11 a REPAIR ReAELOCATE 72 NO HORK UNDER THIS SECTION 73 DM510f1 - CONVEYING SYSTEMS P ' E RFROVDE17; hi6TALLLSM E•D45TN%PRsPATOI a REPAIR, SURROGATE 74 NO WORK UNDER TENS SECTION 15 DIVISION 15000 - MECHANICAL P 1 E P■E OOVDEr hl6TAUED,E•Dai5TRIS%FR•PARGRa REPARRapalOGATE 76 ROOF WORK • 77 HMAG ROOF TOP ECUIFtE ANT ■ • 1 % WAG OISTROMON , DUCTWORK • 79 MAWS • SEE N'ECHANIGAL PLAN FOR ADDITIONAL REC,IARF NTS ; • EXHAUST FANS AND VENTING • ci DUCT DETECTOR FOR HYAG %M OM • ; ►. FEE SPRINKLER MAIN • M SPRI,1 1_ R HEADS 6G GC • SEE MECHANICAL PLAN FOR ADDITIONAL REMR@VNTS = sPRoct.ER SYSTEM rJODiFICATIA1ri 6G 6G • SEE ' PLAN FOR ADDITIONAL REQUIREMENTS M PLATEN& FIXTURES 6G 6G • LAVATORY TO BE RELOCATED % , MOP soK 6G 6G 81 WATER NLr! SalER S11.6 • % % A...CEs PANELS • 0 HATER HEATER • — 0 Ni/LO POKING FON AN GG 6C q1 HATER COOLER WA q2 DIVISION 16000 - ELEGTRICA. q3 ELECTRICAL SERVICE • PANG. E 13EGTRICAL FIRE ALARM WA , ';, EMERGENCY LIGHTING • 97 EXIT 5E0e5 • • ; LIGHT RX1l% S 6G 6G • . , LA."PS 6 _46G 5 • . TIERMOSTAT5 • f 5 .i SYSTEM T T = 5C4210 SYSTEM 5PEA GG - 6L. TO MIRE BACK TO CASHDE5K NTH 6' 1•HPS .., TELEPI ONE SYSTEM T T nw lafFIONE CCHOUIT AND RILL SITING NR/6 GG GC MRN*. COMING. RECEPTACLE'S, SNTOES 6G - • 6.G TO PROVIDE ALL MEM TENANT ITEMS AP 6C .71 CONDUIT, NRIN6 AND G0144EGTkON OF CAROR - * 1 POKER POLE 1 TO GA RAP 2 CO :104 CA9HRESe5TEr3R SYSTEM T T Ti" GLOM. FOR STOREFRONT 516N • 10 GAMES WORKSHOP STANDARD FINISH LEGEND SYMBOL. LOCATION I TYPE I STYLE DESGRPlON I MiF6. GATA.iOEs • I REMARKS FLOORING ® RETAIL AND NON S LES AREA VNYL TILE EARTH Macs SEAS TRAIN NG_ EMC �I814 146 MATERIAL SUPPLIED 8Y TENANT Slap -i, WirI 5hpp - -1, NCI TOILET ROOM VGT BUILDING STANDARD ARMS 5Nq{5 FLOORING MATERIAL SUPPLE BY 6G. FGI 6E P -3 told oranges slsa• be made to the mops c : r ?G 11C without odor approval cf Si RETAIL AND NON SALES AREA vNYL EASE 4' HIGH VINYL COVE BASE 320EMTE DiG-4 orr�NO BASE MATERIAL. SUPPLIED BY G.G. BASE MATERIAL SUPPLED BY &c. I 7::::x33 cu::4 ag DDiv:::: :::. t:07::: rFtsr;;;a1S LY.7 '. •- ;'- , t. r�eyt ve a nett, ;:.; s_...� L �� �/ Include ! •ev, fzes. . P -3 P -3 TOW ROOM P -3 4 ' WGH VINYL CLOVE BASE .IdIi�60111TE B2 WALL FUSS RETAIL SALES /PEA fi'8iE INDICATED 5LAT1iALL SLAflWl. tem HIGH F R 4 1 S H 4 5 1 8 ' I _ ALAI* M *ISMS, FROM PROVIDED NTH! E3LAGK P2LL5I* P TENANT NT T O PROVIDE BLACK AL U M I N M TRIPS F O R A N D I atisivE AND END GOIOITKJNIS P6 Ei8t OF RETAIL PW 6A1"• & AREA FROM MUMS LRE DiOM won_ GRAPHIC 0.15104 VINYL 6RAPliG NALL GOyER'A16 ROLL MATERIAL TENANT C TENANT PROVIDED GRAPHIC MAIL COVE REVS Ca P -I 6sAlll 4G AREA MAILS NV RETAIL AREA ABOVE SLATMALL MERE NDC.ATN3D PAW) ORANGE - 'C.EYE7air SteRMA NILLIN"G SP. .861 PROVIDE RECOWENDED PRIMER AND 2 FI1iS1! GOATS, SAM FLUSH ON AU P1041.5 p- RETAIL I NON SALES DOOR AND FRAME PAINT BLACK - 'TRICORN CLACK' K' SHEMIN Sri 6?S8 PROVIDE PRIMER AND 2 FINISH COATS, GLOW. FINISH ON ALL TRR4 p - 3 NON SALES AREA P0115 PAIIT PefilE - AURA 14 TE SNERNIN 94-6532 PROVIDE RECOMMI34DED PRIMER AND 2 F S H COATS, SATi 4 FR`45I1 ON ALL MALLS NON SAES AREA HALLS PANT BLACK - FLAT ACK FL B SHEMIN 91-830840C (an ROOM FINISH SCHEDULE nor MEW UM MINIMP .ir III RM. N O ROOM NAME FLOOR BASE HALLS - ( E TYPES CEILING HT. NORTH SOUTH EAST NEST 101 RETAIL AREA FGI 8I Slap -i, WirI 5hpp - -1, NCI P PAM EX- SUSP. ACOUSTICAL TILES 10' -0 A.F.F. 102 NON SALES FGI 6E P -3 P -3 P -3 P -3 NEW ACOUSTICAL TILES OPEN TO STRUCTURE 103 TOILET ROOM FG2 B2 . P -3 P -3 P -3 P -3 NEW ACOUSTICAL TILES . 80-O' AFF. a RESPONSIBILITIES • • PROJECT: PROJECT KEY PLAN GAMES WORKSHOP PARKWAY SQUARE 16814 SOUTH CENTER PARKWAY TUKWILA, WA g8188 DRAFTING SYMBOLS ELEVATION REFERENCE SHEET NUMBER X SECTION REFERENCE I X SET NUMBER PROJECT ADDRESS: LANDLORD: TENANT: a PROJECT DATA /DIRECTORY GAMES 1ORKSHOP TACOMA CENTER 1921 SOUTH 12nd STREET TACOMA, WA 98408 IIiII1L. - ! /. , T'7 7 f/ °•77 :1 - MAGNDLA il _ 1:1111t 3 if i! I j 1IIII11 GAMES WORKSHOP 6121 BAYMEADOW DRIVE GLEN BUURNIIE, MD 21060 -6401 MR John Beauchonp TEL: (410) 540 -1400 DETAIL REFERENCE SHEET NUMBER 0 m tO ® NOTE NUMBER REFERENCE v m m TACOMA PLACE ROSIN PROPERTIES 1715 84th AVE l3N SUITE 1212 BELLEVUEE, WA 98004 Tel.: (425) 454 -3030 x1350 CONTACT: VICKY MNGDERMONTT PARKWAY SQUARE 16874 SOUTH CENTER PARKWAY TUKWILA, WA 98186 0 m L • SOUTH 168TH ST. ACD REVISION / ADDENDUM I d i e ENGINEER OF RECORD DOOR TYPE REFERENCE PROJECT COORDINATOR: -1 • DIMENSION TO FACE OF WALL FINISH REFERENCE GADD TECH MR. DONALD KAI4I 113 ELM STREET, SUITE 103 E•FIELD CT, 06082 Tel. (860) 253 -'Nb8 ARCHITECT OF RECORD: KENN BUTTS, AIA 124 Stagecoach Road Bell anon, GA 41307 TEL: (!318) 999 -4212 THE LEVY GROUP Mr. Donald Spencer 6515 East 82nd St, Suite 206 Indianapolis, IN. 46250 Tel. OM 914 3400 Rte_ • CODE SUMMARY AUTHORITIES HAVING JURISDICTION: (BUILDING DEPARTMENT) TUKWILA BUILDING DEPARTMENT 6300 SOUTH CENTER BLVD., SUITE 100 TUKWILA, WA 98168 TEL. (206) 431 -3610 APPLICABLE CODES: THESE DRAWINGS AND ALL CONSTRUCTION WORK SHALL CONFORM TO THE FOLLOWING BUILDING CODES AND LOCAL AMENDMENTS: BUILDING CODE: 2003 INTERNATIONAL BUILDING CODE IH/ WASHINGTON STATE AMENDMENTS WASHINGTON STATE BUILDING CODE ELECTRICAL CODE: PLUMBING CODE: MECHANICAL CODE: FIRE PREVENTION CODE: ACCESSIBILITY CODE: ENERGY CODE: 2004 WASHINGTON STATE ENERGY CODE EXISTING BUILDING DATA: USE / OCCUPANCY GROUP: CONSTRUCTION TYPE: SPRINKLER SYSTEM: PORTABLE FIRE EXT.: GROSS FLOOR AREA: OCCUPANCY LOAD: OCCUPANCY CALCULATIONS: ROOM DESCRIPTION GAMING AREA TOILET ROOM STOCK ROOM MAXIMUM TRAVEL: TABLE 1015.1 250' MAX. SPRINKLERED N MISER OF EXITS PER OCCUPANT LOAD: SECTION 1018.1 NUMBER OF EXITS: SECTION 1018.2 DRAWING INDEX GENERAL T -I ARCHITECTURAL Y of Tit wiIa A-O EXISTING CONDITIONS FLOOR AND CEILING PLANS g1��L 11G Q1VI B A -I FLOOR PLAN, DOOR SCHEDULE, SCOPE OF NORK NOTES A -2 REFLECTED CEILING PLAN, LIGHT FIXTURE SCHEDULE, SCOPE OF (WORK NOTES A -3 INTERIOR ELEVATIONS AND PARTITION DETAILS A -4 TOILET ROOM PLAN, ELEVATIONS AND DETAILS MEP ENGINEERING 2003 UNIFORM PLUMBING CODE P1/ WASHINGTON STATE ADMENDMENTS 2003 INTERNATIONAL. MECHANICAL COPE rd WASHINGTON STATE ADMENDMENTS 2003 INTERNATIONAL FIRE GORE W/ WASHINGTON STATE ADMENDMENTS 10198 ICC /ANSI A111.1 SECTION 30R: (4) MERCANTILE TABLE 601: TYPE LIB (EXISTING BUILDING) YES, Per NFPA 13 YES, Per NFPA 10 1068 S.F. 30 ROOM OCCUPANT AREA FACTOR 85q S.F. 30 2q 4q S.F. 160 S.F. 300 1 1068 S.F. 30 MEP-I FLOOR PLAN ELECTRICAL AND MECHANICAL WORK MEP-2 FLOOR PLAN PLUMBING WORK MEP-3 SPECIFICATIONS OCCUPANT OCCUPANTS 2 EXITS LOAD FOR 2 EXITS REQUIRED 50 OCCUPANT LOAD 1 -500, 2 EXITS REQUIRED 50 OCCUPANTS AND 15 FEET TRAVEL DISTANCE I EXIT REQUIRED - I EXIT PROVIDED I IttI(jC JED OR CODE COMPLIANCE TITLE SHEET, CODE SUMMARY, RESPONSIBILITY CHART •-tr.T•r." ) GENERAL NOTES \ FEB 2 62001 Man review approval Is subject to ertois and =Wow. ApFoval of construction doctmnents does not al11i>Iorflle the violation cf £rr/ ac0 p ed code or ord1nanc . Receipt of approvti 1 CC, -- d condtor s 1; oudedged: Dat By 7 F SEPARATE PERMIT REQUIRED FOR: IdlNecharicai L3ecblcal L'P1i snbi g 1Q6 N�,pirag C1'ty of Tukwila BUDDIN ; DIVISION City of Tula BUILDING DIVISION NO NO • (818) 999-4272 a cc CC w Qw� Urn Q O � co 00 Nz CC ;2 F. KENN BUTTS KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 ISSUED: 11/22/06 REVISIONS: NO. DATE: DESCRIPTION: 06-034 Job No. KB. STAFF Prof. Mg SHEET TITLE: TITLE SHEET SCALE: NONE SHEET IIAHBER: Drawl 139 KB. Checked e1 T -1 Tenant Space: Area: 1068 S.F. SOUTH CENTER PARKWAY EXISTING UGHT FIXTURE SCHEDULE: SYM MARK DESCRIPTION MFG CATALOG' LAMP TYPE VOLTAGE MOUNTING QTY. _ REMARKS . EX/A 2x4 RECESSED FLUORESCENT LIGHT FIXTURE BLDG. STANDARD XXX (4) 3214-T8 120 RECESSED 15 EXISTING TO REMAIN, RELAMP ALL FIXTURES (COOL WHITE) COUNT INCLUDE-5 'NI.' I.' FIXTURES o ii 2x4 FLUORESCENT LIGHT FIXTURE K.= NIGHT LIGHT CIRCUIT. ST/ STANDARD (4) 32W-T8 120 RECESSED 3 EXISTING TO REMAIN, RELAMP ALL FIXTURES (COOL MITE) I Ex/D EXISTING TWO LAMP 4'-0' STRIP LIGHT WITH CHAIN KIT BLDG. STANDARD XXX (2) 32W -T8 120 RECESSED 3 VERIFY PROPER OPERATION 1 ® EX/X EXIT SIGN OLDS. STANDARD )00( INCLUDED 120 SURFACE MOUNTED ! VERIFY PROPER OPERATION MISC CEILING FIXTURE SCHEDULE: El I EXF IEcT FAN STANDARD )()()( I - I - I RECESSED I I I TO BE REMOVED ' EX. WALL TYPE SCHEDULE: SYM DETAIL DESCRIPTION Ming NONE EXISTING EXTERIOR / LEFT WALL CONSTRUCTION A) DEMISING WALL: EXTERIOR MANSONRY WALL FULL HEIGHT TO ROOF DECK. NONE EXISTING TENANT RIGHT DEMISING WALL: A) METAL STUD FRAMED WITH 518' TYPE 'X' GYP. BD. FULL HEIGHT TO ROOF DECK. G.G. TO PATCH AND REPAIR READY FOR PAINT. NONE TO BE REMOVED -V a • • q 1101 II I 121131151161 EX STOCK ',EX. TOILET E. ROOM *102 ROOM 11103 • II TOLET ROOM T 1 OL2k $6M.8' O' EX-6TP. 60. 01.6. 0 F.X/A EX/Y EX/A 0 EX/A x aNNINIO LEASE DIMENSION 0 EX/A LEASE DIMENSION 4 0 .EX/A EX. CONDONS CEILING PLAN SCALE: vr-r-a EX. CONDI1IONS FLOOR PLAN xuE Varo 0 EX/A BALES AREA 0 EX/A 0 EX/A 213141561118 TYPE.Ga IUGrn 17-0' EX-ACOUSTICAL CL6. • CEILING TYPES I cu i cu I cul LANDLORD BASE BUILDING 2x4 SUSPENDED AG.GOUSTIGAL CEILING WITH WHITE LAY -IN PANELS (SEE PLAN FOR HEIGHTS IN EACH ROOM OR AREA) LANDLORD BASE BUILDING GYPSUM WALL BOARD CEILING (SEE PLAN FOR HEIGHTS IN EACH ROOM OR AREA) OPEN TO STRUCTURE ABOVE 0 F.xiA 0 A 0 ,EX/A EX/X Ir 0 pi I • • • • • MISCL CEILING LEGEND EX. CONDMONS CEILING NOTES: EX STOREFRONT STOREFRONT TO REMAIN, NO WORK 15 REQUIRED. 0 EX. ROOF EX RETAL AREA: 101 0 6 II LI7 0 G.C. 15 RESPONSIBLE FOR REPORTING ANY ROOF LEAKS OR DEFAULTS THAT YOU WITNESS OR OBSERVE DURING DEMOLITION PHASE AND REPORT THEM TO THE GAMES WORKSHOPS CONSTRUCTION MANAGER. RETAIL AREA 2 X 4 ACOUSTICAL CEILING SYSTEM AND GRID TO REMAIN. G.G. TO REPLACE ANY DAMAGED OR STAINED CEILING TILES IV NEW TO MATCH EXISTING, AS REQUIRED. RETAIL AREA 2 X 4 FLOURESCENT LIGHTING TO REMAIN. G.G. TO REPLACE ANY DAMAGED BULBS WITH NEW AS REQUIRED. EXIT LIGHT FIXTURES TO REMAIN. GC. IS RESPONSIBLE FOR PROPER OPERATION. SPRINKLER SYSTEM TO REMAIN, NO WORK 15 REQUIRED. HVAC SUPPLY AND RETURN DIFFUSERS TO REMAIN, NO WORK IS REQUIRED. EXISTING OUTLET AT STOREFRONT TO REMAIN. EX STOCK ROOM 102 0 I0 m STOCK ROOM 4' STRIP FLOURESCENT LIGHTING TO REMAIN. G.G. TO REPLACE ANY DAMAGED BULBS WITH NEW AS REQUIRED. EXIT SIGN OVER REAR DOOR TO BE REMOVED. EX TOILET ROOM 103 EXISTING TOILET ROOM CEILING AND EXHAUST FAN TO BE REMOVED. EX. EDITIONS FLOOR PLAN NOTES GENERAL GENERAL CONTRACTOR TO HAVE A DUMPSTER ON SITE IF HEEDED AND MUST KEEP TIE SPACE CLEAR OF TRASH. EX STORMONT O EX. RETAL AFEA: 101 El 0 6 8 L3 10 m CM rs 13 15 16 EXISTING SUPPLY AIR DIFFUSER EXISTING RETURN AIR REGISTER EXISTING SPRINKLER HEADS STOREFRONT TO REMAIN, NO WORK REQUIRED. UNL.E55 STOREFRONT GLASS 15 BROKEN OR ENTRY DOOR IS NOT OPERATIONAL. REMOVE ALL REMAINING PERVIOUS TENANT FIXTURES. ALL ELECTRICAL CONDUIT AND WIRING TO BE REMOVED. REMOVE EXISTING SLATWALL., TENANT DEMISING WALLS TO REMAIN. WALLS TO BE PATCHED, SKIM SEAMS AND SANDED SMOOTH READY TO ACCEPT NEW TENANT FINISHES. EXISTING CUTLETS TO REMAIN. G.G. TO REMOVE EXISTING FACE PLATES, SEE SHEET A -I FOR IEt4 REQUIREMENTS. EXISTING SALES/STOCK ROOM DOOR, FRAME AND HARDWARE TO REMAIN. REMOVE EXISTING CARPET AND VINYL BASE. ALL ADHESIVE TO BE REMOVED BACK TO COW RETE SLAB EXISTING CONCRETE SLAB TO BE MADE FLAT, SMOOTH AND READY FOR NI31 TENANT FLOOR FINISHES. EX STOCK ROOM 102 REMOVE EXISTING CARPET FLOOR AND VINLY BASE. ALL ADHESIVE TO BE REMOVED BACK TO CONCRETE SLAB. EXISTING CONCRETE SLAB TO BE MADE FLAT, SMOOTH AND READY FOR NEW TENANT FLOOR FINISHES. . TENANT DEMISING HALLS TO REMAIN. WALLS TO BE PATCHED, SKIM SEAMS AND SANDED NTH READY TO ACCEPT NEW TENANT FINISHES. REAR DOOR TO BE CLOSED AND LOCKED FROM THE INSIDE. DC TOILET ROOM= EXISTING WATER CLOSET AND TOILET PAPER HOLDER TO REMAKE E)OSTING LAVATORY AND MIRROR TO BE REMOVED AND SAVED FOR RELOCATION, SEE SHEET Al - FOR NEW LOCATION. EXI5TIM5 MATER HEATER TO REMAIN. G.C. TO PROVIDE SUPPORT FOR rCATEt HEATER EEFOR£ REMOVAL OF TOILET ROOM PARTITIONS EXISTING TOILET ROOM* PARTITIONS, DOOR, FRAME AND HARDMARE TO BE REMOVED. ALL ELECTRICM TO BE BROUGHT BACK TO SERVICE AND REMOVED. REMOVE EXISTING V.G.T. FLOOR AND WILY BASE_ ALL ADIESI\/E TO 8E REMOVED BACK TO CONCRETE SLAB EX ELECINCAL BEGTRICAL PANE. TO REMAIN. SEE ELECTRICAL DR PINGS FOR MEM REGAREHENiS EX WAC 16 GL. TO REPLACE HVAG FILTERS AFTER DEMOLITION IS COMPLETE. • KENN BUTTS (818) 999 -4272 KENNETH L. BUTTS ARCHITECT AlA 124 STAGECOACH ROAD BELL CANYON, CA 91307 ISSUED: 11/22/06 REVISIONS: NO. DATE: DESCRIPTION: 06-034 Job No. KB Q fr cr �Z o ° o �U QO CO NL CC s Iron. M9r. ��HEET N ER: STAFF KB. JAN L3 Draw 139 Checked By SHEET TITLE: EX CONDITIONS FLOOR PLAN SCALE: 1/4' s 1 A -0 I Tenant Space: LEASE DIMIMENSION WALL TYPE SCHEDULE. . SYM .. I DETAIL! DESCRIPTION SIZE DOOR FRAME THRESH. LATCH LOCK FUNCTION NONE EXISTING EXTERIOR / LEFT WALL CONSTRUCTION A) DEMISING WALL: L t► • EXTERIOR MANSONRY WALL FULL HEIGHT TO ROOF DECK. WIDTH FIGHT. THK. NONE EXISTING TENANT RIGHT DEMISING WALL: A) METAL STUD FRAMED WITH 5/8" TYPE "X" GYP. BD. FULL HEIGHT TO ROOF DECK. G.G. TO PATCH AND REPAIR READY FOR PAINT. -. MAT. FIN. 6/A.-3 5 /A - S NEW INTERIOR PARTITION A) 3 5/8" METAL STUDS 0 16" O.C. WITH 5/8" TYPE "MR" GYP. BD. (WET AREAS ONLY) AT INTERIOR TAPE, COMPOUND AND SAND SMOOTH READY FOR WALL FINISHES. FINISHED GYP. 1317. SHALL ALIGN 111TH ADJACENT WALL FINISHES. B) 184 K E61ALLS 0 4'-O' IWH 14313 5/0' X 206A HETA1. S11A5 0 16' CAC. MV 5/8 TYPE 'X' 6YP. IDD USE TYPE I'R GYP. BD FOR PET AREAS 7:1:2Z DOOR SCHEDULE .. USE SIZE DOOR FRAME THRESH. LATCH LOCK FUNCTION FIRE LABEL 16 L t► • REMARKS WIDTH FIGHT. THK. MAT. .--- FIN. -. MAT. FIN. ii0 0 ENTRY DOOR 3.-°- T-0" - - -- ALUM./ GL ASS A 't 3. Ai. l k•1. ANOD. ALUM. PUSH/ PULL ENTRY •• ... E EX L.L. BLDG STANDARD DOOR AND HARWARE O STOCKROOM 3' -O' T -O' 1 -3/4" GORE! PAIN1ELI , :ETAL ` PAINTED NONE LEVER 5ET PASSAGE - - -- EX LL. BLDG STANDARD DOOR AND HwRwARE O TOILET ROOM 3' -O' 7 " -0' 1- 3/4 " GO5RE11'^ PAINTED M METAL PAINTED NONE LEVER SET PRIVACY - - -- A I NEW DOOR FRAME AND HARWARE BY G.C. 9 METAL FRAME PAINT P2 SOLID WOOD FLUSH DOOR INSTALL GRAPHIC LEVER SET EXTERIOR MALL WALL JAMB TYPE 'A' TYPE A SOLID CORE FLUSH DOOR 3' -0' ri, 7' -5' STOCK ROOM ROOM 102 NOT APART OF SPACE • i CLOSER KICK PLATE (ONLY ON PUSH SIDE (TYP. • JAMBS) (2) 20 GA. MIL. STUDS a CASING. METAL FRANCE, STOP, 16 GA. PREFINISHED JAMB ANCHOR DOOR BD. EACH SIDE W/ 5/8" TYPE 'X' GYP_ 3 5/8' STEEL STUD WALL (NOTE: HEAD SIMILAR) T 1 I I I 6'-9" 18119 1211 EX. TOILET ROOM 103 - --�— 1 I I - - rriEh rtim:•ws-.w w ir - gwi- t . l agag• 11•11 - - s I 3'-6" , EXIS' i 3'-O' 3'-6' GROUP I, DOOR l3 SOLID FLUSH WOOD DOORS, WITH lb GA KD METAL FRAME FOR 4 1/8" WALL A. STANLEY: FULL MORTISE, ANTI FRICTION BEARING STANDARD WEIGHT HINGES I\PR X 3, FBB 179 (11526D) 4\ X 4\ BUTTS B. LEVER SET- G. SELF CLOSING DEVICE: LCN, MFG. NO. 1460 -AL , FINISH: ALUMINUM (OR EQUAL) D. FLOOR MOUNT DOOR STOP: - IVES 11FS436 (OR EQUAL) E. DOOR SILENCERS F. STAINLESS STEEL KICK PANEL 10 LCN 11 8400 (LOCATED PUSH SIDE OF DOOR) (OR EQUAL) TABLE 48 X 12 F5 TABLE 48 X 72 F5 SCALE 1/4°4-0' 21'-O' MU CAYENNE (FULL HEIGHT) 3' 3' FLOOR PLAN 21'-6' TABLE 48 X 12 ES TABLE 48X 12 P5 "BEST" 7K SERIES (OR EQUAL) MFG. NO. 1- N- 15- C3 -5TK -626 FUNCTION: PRIVACY CAYENNE (FILL HEIGHT) 3' -0" 6q.-O • LEASE DIMENSION I TABLE 48 X 72 F5 TABLE 46 X 72 F5 5' G. TO INSTALL TRIM AT PAINT LINE i 0 G.C. TO INSTALL TRIM AT PAINT L1I , ® GRAF/116 I11AM COVER ABOVE • 53 4 6 O m 31'-6` HANDICAPPED CHECK OUT NOTE. MOUNT OUTLET BOXES TO INSIDE FRONT VERTICAL FACE OF GASI^RAP Fl CAM I DEW us 32' -0' SLATWALL TO 9'-4' AFF. PAINT (PI) CAYENNE (FULL HEIGHT) HANDICAP 9JP- UP COUNTER O mama 34' AFF. WICK SLATHALL TO 4'-4* AFF. PAINT (pi) CAYENNE (FULL HEIGHT) 4 SPEAKER WIRING .B FOR TERMINATION OF QUAD FOR MISC. POKIER some nave cam • I' -7• CASHWRAP POWER ELEVATION DETAIL SCALE ur-r -n LJ / I (U DEDICATED 16 DUPLEX QUAD FOR PO5 SYSTEM PHONE FAX u. R COO 11 , t'" l p ice,1 00, n 000--:04v DUST N& STOREFRONT O Z F Q 0 GENERAL NOTES: B D THIS SPACE IS COMPLETELY BUILT OUT BY THE LANDLORD UNDER THE BASE BUILDING PERMIT. THE SCOPE OF WORK IS THE INSTALLATION OF SALES/STOCKROOM PARTITION. TENANT INTERIOR FINISHES AND FIXTURES ONLY. G.C. SHALL OBTAIN C OF 0 AT COMPLETION OF PROJECT. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS AS IT RELATES TO THE SCOPE OF WORK, PRIOR TO SUBMITTING THEIR BID. NO EXTRAS OR CHANGE ORDERS WILL BE WILL BE APPROVED FOR UNFORESEEN COSTS ASSOCIATED WITH COMPLETING THE SCOPE OF WORK. THE CONTRACTOR 15 REQUIRED TO PERFORM A THOROUGH GLEANING OF THE COMPLETED SPACE PRIOR TO TURNOVER. COMPLETING DATE WITH THE CERTIFICATE OF OCCUPANCY IS TO BE NO LATER THAN THREE DAYS PRIOR TO THE GIVEN STORE OPENING DATE. THE CONTRACTOR SHALL SUPPLY AND INSTALL FIRE EXTINGUISHERS AS REQUIRED BY LOCAL CODE. MINIMUM OF (2) 2AI013C EXTINGUISHERS MOUNTED AT 36" A.F.F. MAX TRAVEL TO EXTINGUISHERS SHALL BE 15' THE CONTRACTOR IS RESPONSIBLE TO HAVE AN DUMPSTER ON SITE IF NEEDED AND MUST KEEP THE SPACE CLEAR OF TRASH. FLOOR PLAN SCOPE OF WORK GENERAL, THIS SPACE HAS BEEN BUILT OUT BY THE LANDLORD AS A COMPLETE VANILLA BOX TO INGUDE STOREFRONT, DEMISING WALLS, TOILET ROOM, ELECTRCAL SERVICE, CEILING, LIGHTING, HVAG SYSTEM, AND FIRE SPRINKLER SYSTEM. THE FOLLOWING KEYED NOTES DESCRIBE THE TENANT IMPROVEMENT WORK THAT NEEDS TO BE COMPLETED. STOP EXTERIOR U Ell GC. TO COORDINATE WITH GW PROJECT MANAGER AND 51614 CONTRACTOR FOR SIGN LOCATIONS. VERIFY EXISTING OR PROVIDE AND INSTALL REQUIRED ELECTRICAL FEEDS, JUNCTION BOX, AND MANUAL TIMER FOR SIGNS AS DIRECTED. EXISTING STOREFRONT TO REMAIN NO WORK REQUIRED. RETAL APE* '101 CARPENTRY AND FINISH WORK 6 0 8 GENERAL WALLS: ALL WALLS SHOULD BE READY TO RECEIVE PAINT, G.G. TO INSPECT AND REPAIR ANY AREAS AS REQUIRED PAINTING: - GENERAL SALES AREA AND GAMING AREA WILL BE PAINTED (PI) CAYENNE SW 11688!, SATIN - TRIM SHALL BE PAINTED (P2) BLACK SW11 6258 SEMI GLOSS - NON SALES AREA SHALL BE PAINTED (P3) AURA WHITE 51111 6532, SATIN - CEILING, DIFFUSERS AND SPEAKERS SHALL BE PAINTED (P4) SW 11 B30B400, FLAT INSTALL PROVIDED SIMULATED WOOD PLANK VGT FLOORING, SWIFF -TRAIN CO. ITEM EARTH /NEWS 11GWC 4814, AND 4" VINYL COVE JOHNSONITE 111x - 4 (BLACK). NOTE SET • FLOORING MUST BE INSTALLED PRIOR TO THE GASHDESK BEING ET IN PLACE. G.G. TO INSTALL, GAMES WORKSHOP SUPPLIED SLATWALL WHERE INDICATED IN THE DRAWINGS. ALL SLATWALL FASTENERS SHALL BE COUNTERSUNK PRIOR TO METAL INSERTS BEING INSTALLED. THERE IS TO BE NO DIVIDERS OR TRIM BETWEEN SHEETS OF SLATWALL. SLATWALL SHALL BE TRIMMED WITH BLACK SLATWALL ALUM. TRIM COMPONENTS AT END CONDITIONS AND CORNERS. REFER INTERER ELEVATION SHEET A -3. INSTALL SUPPLIED GAMES WORKSHOP GRAPHIC BOARDER WALL COVERING ABOVE THE SLATWALL. THE BOARDER 15 TO BE INSTALLED FROM THE CEILING LINE P01*1. A MINIMUM OF 3" CAYENNE STRIPE TO BE VISIBLE BETWEEN THE TOP OF SLATWALL AND BA. GRAPHIC WALL COVERING. EXISTING INTERIOR DOORS, FRAMES, AND HARDWARE SHALL BE INSPECTED AND REPAIRED WHERE REQUIRED FOR PROPER OPERATION. SEE NOTE 4 FOR FINISHING REQUIREMENTS. EXISTING EXTERIOR DOORS SHALL BE INSPECTED AND IN PROPER WORKING ORDER. FIXTURE / CASHFRAP INSTALLATION: q SPECIFIC ELECTRICAL 10 fi 16 ril IS ED CONTRACTOR TO RECEIVE, ASSEMBLE AND INSTALL ALL GAMES WORKSHOP FIXTURES IN LOCATIONS SHOW ON THE FLOOR PLAN. WHERE ELECTRICAL 15 REQUIRED SUPPLY AND INSTALL AS NOTED BELOW. GASH} AP: THE CASH WRAP IS TO HAVE THE FOLLOWING: A,) PROVIDE 1 QUAD RECEPTACLE WITH (I) 2OAMP DEDICATED DUPLEX RECEPTACLE 1911TH ISOLATED GROUND FOR CASHREGISTER. THE OTHER DUPLEX ON THE SAME CIRCUIT AS THE OTHER QUAD. ADJACENT_ B ) PROVIDE (I) QUAD RECEPTACLE ON ONE 20AMP DEDICATED CIRCUIT FOR OPTIONAL EQUIPMENT. C,) PROVIDE (2) LIVE PHONE LINES a (I) SPARE FROM THE D -MARK TO THE INSIDE OF THE CASH DESK. D.) PROVIDE (I) JUNCTION BOX FOR THE SPEAKER WIRES. NOTE ALL DEVICES ARE PRE - MOUNTED ON THE INSIDE OF THE GASH/ AP. THE CONTRACTOR SHALL ROUTE ALL CONDUIT THROUGH A RACEWAY SURFACE MOUNTED TO THE INSIDE OF THE CASKAIRAP RETURN PANEL. THE RACEWAY SHALL BE BLACK TO MATCH THE CASHWRAP. ALSO SEE CASIWWP PART ELEVATION FOR LOCATION OF ALL DEVICES. DUPLEX RECEPTACLES FOR THE GLASS DISPLAY TOWERS. RECEPTACLES AND COVER PLATES TO BE BLACK_ WHERE EXISTING RECEPTACLES ARE TO REMAIN IN THE SALES AREA THEY SHALL ALSO BE CHANGED OUT TO BLACK_ SEE ELECTRICAL DRAWING_ EXISTING SALES AREA LIGHTING SWITCHES AND COVER PLATES SHALL BE CHANGED TO BLACK DEVICES. EX. STOCKCH00Ik 12 EXISTING ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS FOR NEW REQUIREMENTS_ 6G. TO INSTALL NEW VINYL TILE FLOORING (FC2) AND COVE BASE (B2) BY GC,- GAG_ TO PAINT ROOM (P3) WHITE, AND INTERIOR OF THE DOOR AND FRAME (P3) WHITE. NEW HI DRINKING FOI,TITAIN AND MOP SS) ( BY GG., SEE PLUMBING DRAPCNC� FOR REQUIREMENTS. 3405 GG_ TO INSTALL NEW MOP SINK PARTITION. EX TOLET ROOM 103 G.C. TO it TALL 1Y4 TOILET ROOM PARTITIONS. SEE WALL TYPE SCH'EDU E FOR CONSTRUCTION. G.C. TO INSTALL NEW VINYL TILE FLOC /RING (FC2) AND COVE BASE (B2) BY G.C.- 6G. TO PAINT ROOM (P3) WHITE, AND INTERIOR OF THE DOOR AND FRA`4E (P3) W-IITC_ • RcSrERED Utz -ATECT t BUTTS RELOCATED LAVATORY AND MIRROR BY GC... SEE SI£ET A -4 FOR TOILET ROOM ELEVATIONS AND DETAILS_ '`z. PE.°.' !l i C-t N I _: (818) 999 -4272 KENN BUTTS KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 06-034 Job No. KB. ISSUED: 11/22/06 REVISIONS: NO_ DATE: DESCRIPTION: SHEET TITLE: SCALE: 1/4' =1 .- 0 ' SHEET M MBER: STAFF Dtr% By KB. Prof_ P Checked 89 U cd 0. Co C ai C FLOOR PLAN WORK A -1 Area: 1068 S.F. EXISTING LIGHT FIXTURE SCHEDULE: SYM MARK DESCRIPTION MFG CATALOG# LAMP TYPE VOLTAGE MOUNTING QTY. REMARKS .0 FA. Exp 2x4 FIXTURE RECESSED FLUORESCENT LIGHT T FIXTURE BLDG. STANDARD )00C (4) 3214-T6 120 RECESSED 15 EXISTING TO REMAIN, RELA1rP ALL FIXTURES (COOL WHITE) COUNT INCLUDES NL` FIXTURES c gi 2x4 FLUORESCENT LIGHT ti... NIGHT LIGHT GCIRCUIT. FIXTURE ST STANDARD )00C (4) 32W-T6 120 RECC - SSED 3 EXISTING TO REMAIN, RELAMP ALL FIXTURES (COOL WHITE) EX /D EXISTING TWO LAMP 4'-0' STRIP LIGHT WITH CHAIN KIT BLDG. STANDARD XXX (2) 32P1-T8 120 RECESSED 3 VERIFY PROPER OPERATION 1 I EX/X EXIT 51614 STANDARD )00C INCLUDED 120 MA D E I VERIFY PROPER OPERATION il NEW LIGHT FIXTURE SCHEDULE: BY G.C. SYM MARK DESCRIPTION MFG CATALOG* LAMP TYPE , VOLTAGE MOUNTING QTY. REMARKS .0 FA. FAN / LIGHT GOI.EO 10 0 GFM FAN GROAN OR EQUAL 646 '15W AM RECESSED D MOUNT 120 I GA SUPPLIED 4 INSTALLED BY G. MISCL CEILING LEGEND ®g NEW Au010 SPEAKER BY GC. 4 - EXISTING SUPPLY AIR DIFFUSER EXISTING RETURN AIR REGISTER EXISTING SPRINKLER HEADS • a a i STOCK ROOM 1Yp6C1.I6IIr: VHF ORM TO S1RUCIURE — TOW 91110 ROOM rTYP6K(. `EIGHT: 8 f� -y e° 61.6. CEIUNG TYPES LANDLORD BASE BUILDING 2x4 SUSPENDED AC.C.OUSTIGAL CEILING WITH WHITE LAY -IN PANELS (SEE PLAN FOR HEIGHTS IN EACH ROOM OR AREA) GYP. BD. CEILINGS: 6' X 20 GA METAL STUD JOISTS o 16' v / (I) LAYERS OF W TYPE 'X' GYPSUM BOARD. OPEN TO STRUCTURE ABOVE FIRE PROTECTION NOTE THE LANDLORD PER THE LEASE AGR T. HA5 INSTALLED A COMPLETE SPRINKLER SYSTEM IN THIS TENANT SPACE. ALL REED DRAWINGS, AND PERMITS BY LANDLORD. ALL SYSTEMS TO BE DESIGNED PER *PA STANDARD 13 AND ALL LOCAL CODES. HVAC NOTES= THE LANDLORD IS HAS PROVIDED AND INSTALLED A COMPLETE WAG SYSTEM IN ACCORDANCE WITH THE LEASE A6RI NETCT. El • REFLECTED CEIJNG PLAN ewevrKc E6/ItIFJ1 CL1}IIIr.V -Cf .AJfsTIC+AL Gib. • CEIUNG PLAN NOTES EXTERIOR sroREFnoMI 0 SALES AfF-As 10I El LIGHTING: ALL LIGHT FIXTURES ARE EXISTING AND HAVE BEEN INSTALLED BY THE LANDLORD. EXIT AND EMERGENCY LIGHTING IS EXISTING BY LANDLORD. CONTRACTOR TO SUPPLY AND INSTALL (2) AUDIO SPEAKERS AND WIRE TO GASHDESK JUNCTION BOX. SPEAKER TO BE BY POLK AUDIO, MODEL PLKRG6OI, COLOR NHITE. THE WAG SYSTEM 15 SUPPLIED AND INSTALLED BY THE LANDLORD, INCLUDING ALL DIFFUSERS. DIFFUSERS TO BE PAINTED FLAT BLACK BY G.G. EX. STOCK ROOM 102 0 6 NJ 8 EX. TOILET ROOM 100 0 I0 HVAO 1? SPRINKLER sew El ROOFS GENERAL: THE ENTIRE CEILING SYSTEM 15 EXISTING AS SUPPLIED AND INSTALLED BY LL PER THE LEASE. SEE SPECIFIC KEYED NOTES FOR SCOPE OF WORK. NEW TENANT STOREFRONT SIGN UNDER SEPARATE PERMIT. G.G. TO FIELD VERIFY EXISTING SIGN CIRCUIT AND TIME CLOCK IN PLACE. IF REQUIRED INSTALL NEW COORDINATE WITH TENANT SIGN CONTRACTOR. THE CEILING IS SUSPENDED ACOUSTICAL THROUGH OUT AS INSTALLED BY THE LANDLORD. G.G. TO COVER ALL LIGHT LENSES AND SPRINKLER HEADS, BEFORE PAINTING THE SALES AREA CEILING AND ALL OTHER ELEMENTS MATTE BLACK FINISH. NEW SUPPLY AIR DIFFUSER, SEE MEP FOR REQUIREMENTS. NO OTHER WORK IS REQUIRED. NEW GYP. BD. CEILING BY GL. NEW TOILET ROOM FAN / LIGHT COMBO BY G.G., SEE MEP FOR REQUIREMENTS. NEW 18' x 18' ACCESS PANEL FOR HATER HEATER MAINTENANCE BY G.C.. THE CONTRACTOR SHALL CHECK THE OPERATION OF EXISTING HVAC EQUIPMENT FOR PROPER OPERATION. HAVE EQUIPMENT PROFESSIONALLY TESTED, PROVIDE ROUTINE MAINTENANCE AND CHANGE FILTERS. REPORT ANY ISSUES TO GAMES WORKSHOP PROJECT MANAGER. THE SPRINKLER SYSTEM IS EXISTING AND REQUIRES NO MODIFICATIONS. IF A TEST OF THE SYSTEM IS REQUIRED TO OBTAIN CERTIFICATE OF OCCUPANCY THE CONTRACTOR SHALL OBTAIN ALL PERMITS AND REFLECT THIS IN THE BID. NEITHER GAMES WORKS TOP OR THE CONTRACTOR IS RESPONSIBLE FOR ROOF ISSUES, HOPIEVER DURING THE BUILD OUT PE REQUIRE THAT THE CONTRACTOR REPORT ANY LEAKS OR DEFAULTS TO THE GAMES WORKSHOP PROJECT MANAGER. i �� C�y'P��a C si Poi 2 C tt<<, ..., tSION • n .. z� PE;tni Gam: IESW o TEC; rt + �l.1s.41;TC• (818) 999 -4272 KENN BUTTS KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 ISSUED: 11/22/06 REVISIONS: NO. DATE: DESCRIPTION: 06-034 Job No. KB SCALE: 1/4'_1, SHEET NUMBER: STAFF Dram Bg KB. Prof. Mg-. Checked SHEET TITLE: REFLECTED CEIUNG PLAN WORK A -2 Tenant Space: Area: 1068 S.F. BA. CEILING 8'-0' AFF. 3 5/8" X 20 GA TRACK �--- -- I l �I I I I I I I I I I I I I I SCALE: 3' 4-0' 0:080483 I • S. r + ki l , • e: • , ti. :. . I BAUM ANA I z PARTfl1ON BASE DETAIL TOILET ROOM CEILING: 6' X 20 GA. STEEL JOISTS 0 16' O.C. Pi/ (I) LAYER 5/8' GYP. BD. 351b•X20GAMIL. TRACK SECURED TO SLAB NTH POWDER WITH ACTUATED FASTENERS #3 5/8' X 20 GA PIA. GRACE TO STRUCTURE ABOVE • 48' O.G. ALTERNATING. TO STRUCTURE ABOVE 16 GA CLIP ANGLES TO TOP TRACK AND DIAGONAL BRACING W/(2) $10 SCREW C01.EGTIONS. EA. LEG. CLIP ANGLES AT 48' O.G. MAX. — TOILET ROOM CEILING: 6' X 20 GA. STEEL JOISTS 0 16" O.G. WI (I) LAYER 5/8' GYP. BD. 35/8'X20GA MIL. STUDS 0 16" ()JO., WITH 5/8' 'MR" GYP. BD. PARTITION TOP TRACK DETAIL SCALE: Y -f-0' 35/8 "OR6 "X20 GA METAL STUDS AT 24' O.G. W/ 5/8' 'MR" R• GYPSUM BOARD 3 5/8' X 20GA MIL. RUNNER TRACK 110 SCREWS TO EACH SIDE OF WALL STUD_ 3 5/8 20 GA MIL STUDS O 16' O.C. w/ 5/8' TYPE 'X' GYP. BD. EACH SIDE TO 6" ABOVE CLG. PRIMED PAINTED SURFACE 3 5/8" X 20 GA. MIL. TRACK (2) HILTI *10 PPM SCREWS O EA. lb" O.G. STUD HILTI X -ZF * 32 P8/36M (0.145' SHANK DlA) FASTENERS O 16" O.C. (OR EQUAL) CONCRETE SLAB PARI1T1ON SECTION SCALE 314' 4-0' IX FRT BLOGKMb AS REQUIRED BD. CEILING 0 4'-O' APP. 35/8'X20GA MTL.WJIWER TRACK •10 SCR TO SIDE OF WALL STUD. 3 5/85c 20 6A 1111- STUDS 0 16' O.G. Pt/ 5/8' '1412' GYP 130 EACH SIDE TO 48' PRIMED PAINTED DACE SHEET A-4 FOR MOP SIM SPECIFICATION 3 518' X 206A MIL. TRACK SECURED TO SLAB WTH POWDER MN ACTUATED FASTENERS O 4- t E TA. SLATWALL 8'-O' AFF. A BD. SLATWALL 4' APP. BA_ CEILING 10 APP. BD. GRAPHIC 8'-6' APP. ELEVATION KEY PLAN PITS G.G. TO PAINT FROM CEILING LINE TO 4' BELOW i 1 ELEVATION SCALE 1!4 -T-O ELEVATION SCALE V4' 4-0 TO PAINT FROM CEILING LINE TO 4' BELOW • G.G_ TO PAINT FROM I — CEILING LINE TO 4' BELOW BLACK ENDGAPS SUPPLIED BY GAMES WORKSHOP INST. BY G.G. - EXISTING STOREFRONT ENTRY DOOR Iwo 611 ELEVATION SCALE: va• -r-v EXISTING STOREFRONT ALUM. FRAMING AND GLASS = .0. GEI ING 10'-0' APP. BA_ CEILING s 10 - 0 ' APP. ;p B.O. GRAPHIC 8'-b' APP. • f k6 L G `: r 1 � Sly. \7' TA_ SLATWALL 8'-O' APP. BA_ SLATMALL 4' AFF. PE::.". l:.^_.: : rix r, WU f# i ACC.4 3 • (818) 999 -4272 KENN BUTTS KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 ISSUED: 11/22/06 REVISIONS: NO. DATE: DESCRIPTION: 06-034 Job No. KB. Q Q W CC cc � W� Urn 0 QO� CD � ^ Y a0 a_ :2 A-oj. Mg. Checked By SHEET TITLE: SHEET NUMBER: STAFF Drama By KB A -3 INTERIOR ELEVATIONS / PARTI110N DETAILS SCALE: AS NOTED • :., I % BA. CEILING 8'-0' AFF. 3 5/8" X 20 GA TRACK �--- -- I l �I I I I I I I I I I I I I I SCALE: 3' 4-0' 0:080483 I • S. r + ki l , • e: • , ti. :. . I BAUM ANA I z PARTfl1ON BASE DETAIL TOILET ROOM CEILING: 6' X 20 GA. STEEL JOISTS 0 16' O.C. Pi/ (I) LAYER 5/8' GYP. BD. 351b•X20GAMIL. TRACK SECURED TO SLAB NTH POWDER WITH ACTUATED FASTENERS #3 5/8' X 20 GA PIA. GRACE TO STRUCTURE ABOVE • 48' O.G. ALTERNATING. TO STRUCTURE ABOVE 16 GA CLIP ANGLES TO TOP TRACK AND DIAGONAL BRACING W/(2) $10 SCREW C01.EGTIONS. EA. LEG. CLIP ANGLES AT 48' O.G. MAX. — TOILET ROOM CEILING: 6' X 20 GA. STEEL JOISTS 0 16" O.G. WI (I) LAYER 5/8' GYP. BD. 35/8'X20GA MIL. STUDS 0 16" ()JO., WITH 5/8' 'MR" GYP. BD. PARTITION TOP TRACK DETAIL SCALE: Y -f-0' 35/8 "OR6 "X20 GA METAL STUDS AT 24' O.G. W/ 5/8' 'MR" R• GYPSUM BOARD 3 5/8' X 20GA MIL. RUNNER TRACK 110 SCREWS TO EACH SIDE OF WALL STUD_ 3 5/8 20 GA MIL STUDS O 16' O.C. w/ 5/8' TYPE 'X' GYP. BD. EACH SIDE TO 6" ABOVE CLG. PRIMED PAINTED SURFACE 3 5/8" X 20 GA. MIL. TRACK (2) HILTI *10 PPM SCREWS O EA. lb" O.G. STUD HILTI X -ZF * 32 P8/36M (0.145' SHANK DlA) FASTENERS O 16" O.C. (OR EQUAL) CONCRETE SLAB PARI1T1ON SECTION SCALE 314' 4-0' IX FRT BLOGKMb AS REQUIRED BD. CEILING 0 4'-O' APP. 35/8'X20GA MTL.WJIWER TRACK •10 SCR TO SIDE OF WALL STUD. 3 5/85c 20 6A 1111- STUDS 0 16' O.G. Pt/ 5/8' '1412' GYP 130 EACH SIDE TO 48' PRIMED PAINTED DACE SHEET A-4 FOR MOP SIM SPECIFICATION 3 518' X 206A MIL. TRACK SECURED TO SLAB WTH POWDER MN ACTUATED FASTENERS O 4- t E TA. SLATWALL 8'-O' AFF. A BD. SLATWALL 4' APP. BA_ CEILING 10 APP. BD. GRAPHIC 8'-6' APP. ELEVATION KEY PLAN PITS G.G. TO PAINT FROM CEILING LINE TO 4' BELOW i 1 ELEVATION SCALE 1!4 -T-O ELEVATION SCALE V4' 4-0 TO PAINT FROM CEILING LINE TO 4' BELOW • G.G_ TO PAINT FROM I — CEILING LINE TO 4' BELOW BLACK ENDGAPS SUPPLIED BY GAMES WORKSHOP INST. BY G.G. - EXISTING STOREFRONT ENTRY DOOR Iwo 611 ELEVATION SCALE: va• -r-v EXISTING STOREFRONT ALUM. FRAMING AND GLASS = .0. GEI ING 10'-0' APP. BA_ CEILING s 10 - 0 ' APP. ;p B.O. GRAPHIC 8'-b' APP. • f k6 L G `: r 1 � Sly. \7' TA_ SLATWALL 8'-O' APP. BA_ SLATMALL 4' AFF. PE::.". l:.^_.: : rix r, WU f# i ACC.4 3 • (818) 999 -4272 KENN BUTTS KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 ISSUED: 11/22/06 REVISIONS: NO. DATE: DESCRIPTION: 06-034 Job No. KB. Q Q W CC cc � W� Urn 0 QO� CD � ^ Y a0 a_ :2 A-oj. Mg. Checked By SHEET TITLE: SHEET NUMBER: STAFF Drama By KB A -3 INTERIOR ELEVATIONS / PARTI110N DETAILS SCALE: AS NOTED • TOILET ROOM EQUIPMENT / ACCESSORIES SCHEDULE MARK DESCRIPTION. MOUNTING MAFQ MFG NO. REMARKS DRINKING FOUNTAIN BI -LEVEL BARRIER FREE WALL ELKEY OR EQUAL HTSEBP PROVIDED BY G.G. INSTALLED BY G.G. Q PAPER TOWS_ DISPENSER SURFACE BOBRICK OR EQUAL 8-262 �'� BY G.G. INSTALLED BY GC. O SOAP DISPENSER AGE BOBRICK OR EQUAL 8-2111 INSTALLED BY G.G. INSTALLED BY G.G. 40 18" VERT. GRAB BAR SURFACE BOBRICK OR EQUAL 8 -6806 X IS' PROVIDED BY G G. INSTALLED BY G.G. Q 36" VERT. GRAB BAR SURFACE BOBRICK OR EQUAL 8-6806 X 36" PROVIDED BY &C. INSTALLED BY G.G. 111 -. 42" VERT. GRAB BAR .SURFACE BOBRICK OR EQUAL 8-6806 X 42" '�D� BY G.G_ INSTALLED BY G.G. STAND UP MOP SINK LEGS FIAT OR EQUAL FL -1 PROVIDED BY G.G. INSTALLED BY G.G. Q PLUMBING FIXTURE NOTE I. REFER TO PLUMBING SPECIFICATIONS SHEET MEI FOR ADDITIONAL INFORMATION. MIN. KNEE CLEARANCE MAX. TOE CLEARANCE DRINKING FOUNTAIN SECTION RELOCATED pOSTA15 REL.00,A Elf/ST016 LAVATORY ELEVATION SCALE- 3/8 -f -0• ELEVATION SCALE 31e -r-o 1 BA. CEILING 8'-0" A.F.F. w RELOCATED EXCSTIRS 0 MIRROR RELOCATED EXISTIN& LAVATORY 9 a ACCESSIBLE DUPLEX RECEPTACLE BD. CEILING 8'-0" APP. L EX1511% HATER CLOSET • O 4 D.P. z O d ACCESSIBLE INSTALLATION DIARGRAMS SCALE: 1/2' -.a ELEVATION n z HI DRINKING FO1KTAIN e 0 v 8`-O` APP. OP 1 8` -0" APP. B.G. CEILING T.O. PARTITION e M S 0 TOILET PAPER LIGHT SWITCH ACCESSIBLE SOAP HAND TOWEL DISPENSER CONTROLS DISPENSER DISPENSER DISPOSAL DP EXISTING z 2 C 3 I T I EXISTING TOILET PAPER HOLDER J `r 1 ELEVATION SCALE WC 4-0' MAXIMUM BOWL DEPTH 6 1/2" 30" MIN LAVATORY PLAN i S 2 w 0 • 8' -0" A.F.F. z I • M B.O. CEILING t)f N TO. PARTITION 8' -0" APP. MAX O(CLR. LAVATORY SECTION 0 4 MAXIMUM BOWL DEPTH 6 1/2it z^ � N a" MI KNEE CLR: HAND OPERATED WRIST BLADE STYLE FAUCET ALL EXPOSED PIPING TO BE INSULATED Of 2 II . ( j61 r -3" c SCALD 1/2' -1'-0' 2 " Q 0 I W ne ze a 2 LAVATORY & MIRROR ELEV. TOILET ROOM PL SCALE 3/8' 4-O • / • I • e 1 a I 0) M z 2 M 11 I i lk RESTROOM . •• ••- I PIHITE BRAILLE SIGN PER CURRENT ADA REQUIREMENTS ACCESSIBLE SIGN DETAIL RELOCATED MIRROR 4 LAVATORY I I/4" DIA. — G.B. z • I 2 z 2 2 —M 42" 7 . MIN 9 " FLOOR MOUNT WATER CLOSET ELEV. UNISEX RESTROOM SIGNAGE 39a_41" — SURFACE MO T TOILET PAPER DISP. HALL PERMIT CONTINUOUS APER FLOW 12" I I/2" DIA G.B. • HAND OPERATED FLUSH CONTROL OPEN SIDE RN D 2- 1 4 0 0 5`-0" - EXISTING 0 0 N STING TOILET PAPER DISPENSER 'O GBI p� E EXISTING WATER CLOSET 36" FLOOR MOUNT WATER CLOSET ELEV. CODE 001-.? -.n C��� tint•.. ,. • KENN.- 13.f n STATE. c: rE}sta.•s L4 NCB. (818) 999 -4272 KENN BUTTS KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 ISSUED: 1I/22106 REVISIONS: NO. DATE: DESCRIPTION: 06 -O34 Job No. Q Ne DC Q W � �m CD F 44c Cr) J Q � Cl. .9 A-oJ. Mgr. SHEET TITLE: STAFF Dram 139 KB. Checked 09 TOLET ROOM ELEVATlON3 /DETALS SCALE: AS NOTED SHEET NUMBER: A -4 • PANEL EX. PANEL TO REMAIN LUGS MAIN EX. 225 AMP 120/208 VOLT 3 PHASE 4 WIRE BREAKER EX. 100 AMP CATALOG# LAMP TYPE USE CKT. NO. LOAD BKR SIZE A B C BKR SIZE LOAD CKT. NO. USE EX. RECEPTACLES 1 720 20/ 0 EXIST** 5 (C OOL. REMAIN, RELAMP ALL COUNT INCLUDES 'AIL' FIXTURES o -- 20/1 896 2 EX. LIGHTING 1 3 900 xXX (4) 3211-Ta i IIII +0 � al•• I ii ^ ^ R i m „0 •, • i ■ N • 11 N E . • 1024 4 i EX. WATER HEATER 5 1650 120 RECESSED 3 VERIFY PROPER OPERATION 464 6 EX. NIGHT LIGHTS SIGN 7 1200 INCLUDED 120 SURFACE MOUNTED 360 8 EX. STOCK ROOM REC. EX. SHOW WINDOW REC. 9 180 1000 10 CASH REGISTER AUDIO RECEPTACLE 11 500 --- 180 12 NY CASH DESK CO. NEW STOREFRONT REC. 13 180 t — 14 BLANK BLANK 15 — 20 /1 — — — 16 EX. STOC ROOM LTS 17 292 -- - 18 BLANK 19 — — — 20 21 — — — 22 23 — t — • • i - - 24 25 — --- 26 = u iii — IP1� A A n oi — 28 ! 9 — — — EX. A.C. UNIT 33 t — 0111 III AI • � 01 - - 34 35 — — 36 BLANK 37 — — 38 39 — — • •� • "I — — 40 41 — — — — 42 EXISTING LIGHT FIXTURE SCHEDULE: SYM SYM MARK DESCRIPTION MFG CATALOG# LAMP TYPE VOLTAGE MOUNTING QTY. REMARKS SUPPLY F EX/A 2x4 RECESSED FLUORESCENT LIGHT FIXTURE , STANDARD xxx _... (4) 32W-T8 120 I - — 15 EXIST** 5 (C OOL. REMAIN, RELAMP ALL COUNT INCLUDES 'AIL' FIXTURES o -- EX /A NL FLUORESCENT LIGHT IF N .= NIGHT LIGHT CIRCUIT. STANDARD xXX (4) 3211-Ta 120 RECESSED 3 EXISTING TO REMAIN, RELAMP ALL IN FIXTURES (COOL MITE) . • L EX/D EXISTING THO LAMP 4' -0' STRIP LIGHT HITH CHAIN KIT BLDG. STANDARD XXX (2) 32H-T8 120 RECESSED 3 VERIFY PROPER OPERATION T ® EX /X EXIT 516N STANDARD INCLUDED 120 SURFACE MOUNTED I VERIFY PROPER OPERATION NEW LIGHT FIXTURE SCHEDULE: BY G.C. SYM MARK DESCRIPTION MFG CATALOG# LAMP TYPE VOLTAGE MOUNTING QTY. REMAWS A SUPPLY F FAN /LIGHT G01400 100 GFM FAN BROAN OR EQUAL 616 1511 Alg RECESSED MOUNT 120 I SUPPLIED 4 INSTALLED f3Y 6,C. r AIR DEVICE SCHEDULE MARK SERVICE TYPE MODULE SREFACE BAVCKPAN MFGR. & MOD. NO. B PATTERN NOTES common COMME TYPE A SUPPLY SQUARE 24' X 24' 18” X 1TI" TITUS 1DCA 3 - LAY -IN 4 -WAY 2.4.7 • CONNECT TO EXISTING LIGHT FIXTURE AS EX/X REQUIRED 6 S EX /C S / C 17 EXTEND AND CONNECT TO EXISTING DUCTWORK AS REQUIRED - VERIFY EXACT LOCATION IN FIELD EX 200 g'a • NEW LIGHT/FAN COMBO 17 EX/Y EX. WATER HEATER TO REMAIN (ASSIGN TO CKT. 5) WATER PIPING DIAGRAM NOT TO SCALE EX /A 0 2 - DC. PANEL TO REMAIN E> EX /A 11( • 0 Exel EX. PANEL TO ROOM EX /A/NL DC /A 0 4 EX /A 0 2 OVA 0 4 EXTEND AND CONNECT TO 19.7 EXISTING COLD WATER PIPE IN SPACE - VERIFY EXACT LOCATION IN FIELD. EXTEND AND CONNECT TO EXISTING HOT WATER PIPE IN SPACE - VERIFY EXACT LOCATION IN FIELD. EX / 0 2 EX /A 0 4 CONTRACTOR TO VERFTY ALL CIRCUITING IN FIELD AND ADJUST CIRCUIT NUMBERS AS REQUIRED IN ORDER TO REUSE EXISTING CIRCUITING. CIRCUIT NUMBER SHOWN FOR REFERENCE ONLY. FLOOR PLAN - LIGHTING/MECHANICAL WORK SCALE' 1/4' - r-a Ek/A/NL EX. &C. MT CONTROL TO (xd, REMAIN CONTRACTOR TO VERFW ALL CRC ffE4G R4 FEW AND ADJUST CIRCUIT NUMBERS AS REQUIRED R4 ORDER TO REUSE DUSTING CIRCUITW4G. CRCUTT ?AMBER SHOWN FOR REFERENCE ONLY. DC /A 0 2 EXTEND AND CONNECT TO EXISTING SANITARY PIPE IN SPACE - VERIFY EXACT LOCATION IN FIELD. WASTE AND VENT PIPING DIAGRAM NOT TO SCALE DC /A 0 2 EX /A 0 4 EX.S�PRINKLI}R HEM (TY P[ A FOR 12) FLOOR PLAN - MISCELLANEOUS ELECTRIC WORK SCALE. v.•..o S O3 DF JB FOR SPEAKERS 1 1/2" 1 1/2" 1 1/2" EX /A 0 DC /A 0 4 RUN EXTRA WIRE FOR GROUND RECEPTACLE AUDIO EX /A/M. 10,12 -11 EX 1 1/2' 1 1/2" EX /A 0 4 12 EXISTING VTR SHOWN FOR INFORMATION ONLY THROUGH FLOOR (TYF • EX /A 0 EX /A 0 Bt/* NOTES: ROUTE CONDUIT AND WIRING HORIZONTALLY IN ELECTRICAL RACEWAY ON CASH DESK SIDE WALL 1. PROVIOE WART AG -35-M OPPOSED BLADE VOLUME DAMPER (RECT. 272RS a 23R1) 2. PROVIDE WITH MODEL EC EQUAUZNG ciao 3. PROVIDE WITH MODEL AC -95 OPPOSED BLADE VOLUME DAMPER (SQUARE) 4. PROVIDE WITH MODEL AC -75 OPPOSED BLADE VOLUME DAMPER (ROUND) 5. PROVIDE WITH 1R14 PLASTER FRAME 6. PROVIDE WIMH RUSKIN MODEL CFO FIRE DAMPER 7. LIMIT FLEXIBLE OUCT CONNECTION TO 5' -IT MAXIMUM 8. PROVIDE WITH TITUS MODEL MPI37 INSULATED PLENUM (DO NOT SUPPLY FOR BLANK SECTIONS) 9. PROVIDE PREFAB PLASTER FRAME FOR MOUNTING 10. PROVIDE WITH MODEL AG -15—M VOLUME DAMPER (RETURN RECT. 50F) N EXTRA WIRE FOR GROUND NEW SWITCH CONCEALED FROM VIEW IF NOT EXISTING EX. J —BOX FOR CONNECTION OF NEW SIGNAGE DC SHUN WINDOW RECEPTACLE TO REWR1 EX TC • LOAD DOES NOT INCLUDE EXISTING A.C. UNITS - VERIFY LOADS IN FIELD AND ADJUST LOADS AND OVERCURRENT PROTECTION AS REQUIRED. ELECTRICAL CONTRACTOR SHALL BALANCE PANEL TO WITHIN 10 4 EXTEND AND CONNECT TO EXISTING HOT AND COW WATER PIPE IN SPACE _*" INDICATES PANEL LOCKS "EX TC" INDICATES TIME CLOCK EXTEND AND CONNECT TO EXISTING WASTE PIPE IN SPACE S W. NEW 1 1 2" W. PART PLAN - PLUMBING WORK etas 1/4° 1 PANEL DIRECTORY (SHOWN FOR INFORMATION ONLY) PHASE A PHASE B: PHASE C: TOTAL: CD CEILING DIFFUSER T y TELEPHONE OURET F 1r FAX OUTLET My MODEM OUlLEr ( TT-4 TELEPHONE CONOUTT T.T.B. TELEPHONE TER>IMDIPL BOARD 5---�3 CONDUIT ABOVE FLOOR S-11-4 CO DUR oaow FLOOR NUMBER OF V HOVE RUN CONDOR SINGLE POLE SWITCH DU WALL RECEPTACLE lat 'QUINT' RECEPTACLE MID ISOLATED GROUND QUAD RECEPTACLE Q JIDICTION BOX O SPEAKER s—S-S SPEAKER CONDUIT DC EXISTING TO REMAIN EXR LUSTING RELOCATED 3356 WATTS 3104 WATTS 3086 WATTS 9546 WATTS SYMBOLS AND ABBREVIATIONS W.C. LAN. SAN. D.F. V. W. CM. H.W. FA. FLOOR DRAIN `V THERMOSTAT WATER CLOSET LAVATORY SANITARY SEWER DRINIQNG FOUNTAIN VENT WASTE COLD WATER HOT WATER DUSTING VTR SHOWN FOR INFORMATION ONLY .WC TO REMAIN BALANCE: 8.05 % • * 23 .. � _ �` i • "tea. - �• _= s:, I APPROV 1 ISSUED: II/22/0b REVISIONS: NO. DATE: DESCRIPTION: 06 -034 Job No. Prof. Mgr. SHEET TITLE: FLOOR PLAN ELECT, MECHANICAL AND PLUMBING WORK SCALE- 1/4" = :0" SHEET tfi413ER: t4 iG DraNro 8y DES Checked ej MEP -1 • ELECTRICAL EQUIPMENT AND MATERIAL ISOLATED GROUND "QUAD" RECEPTACLES: TWO (2) HUBBELL /IG- 5362 -1 DUPLEX RECEPTACLES IN A COMMON JUNCTION WITH A 4 GANG COMER PLATE. "QUAIY' RECEPTACLES: TWO (2) HUBBELL #5262 -1 DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. TELEPHONE /MODEM OUTLETS: HUBBELL TYPE RJ11 WITH COVER PLATE. DATA OUTLETS: HUBBELL TYPE RJ45 WITH IVORY COVER PLATE. WIREWAY FOR CONDUITS TO CASHDESK: WIREMOLD WIREWAY. SPEC -MATE TYPE -1 SERIES ENCLOSURES. SIZED FOR 5 SEPARATE CONDUITS AS REQUIRED. COMPLETE WITH COVER AND BLACK FINISH AS DIRECTED BY ARCHITECT. ELECTRICAL WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS. 2. THE SPACE IS EXISTING AND HAS PREVIOUSLY BEEN OCCUPIED. REMOVE ANY EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES. CONDUIT. WIRE, ETC., NOT REQUIRED FOR THE NEW INSTALLATION. ANY UNUSED FIXTURES SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE. 3. THE SERVICE TO THE SPACE IS EXISTING - SERVICE SIZE WAS NOT ABLE TO BE GATHERED, CONTRACTOR TO VERIFY IF SERVICE IS LARGE ENOUGH TO BE REUSED. THERE SHOULD BE NO REWORK OR MODIFICATION REQUIRED OR PROPOSED TO THE OUSTING SERVICE. IF EXISTING SERVICE IS NOT AS LARGE ENOUGH, CONTACT THE ARCHITECT FOR DISPOSITION PRIOR TO BID. ELECTRICAL CONTRACTOR SHALL ENSURE THAT EXISTING SERVICE IS AVAILABLE FOR USE (AS PERMANENT POWER) DURING CONSTRUCTION AS REQUIRED TO ACCOMODATE ALL ELECTRICAL NEEDS FOR CONSTRUCTION, ETC. 4. REUSE THE EXISTING SERVICE DISTRIBUTION EQUIPMENT AT THE LANDLORDS DISTRIBUTION CENTER, INCLUDING OVERCURRENT PROTECTION DEVICES, OVERCURRENT PROTECTION. HOWEVER INSTALLED. SHALL BE AT LEAST 100 AMP MINIMUM. FIELD VERIFY WITH THE LANDLORD THE EXACT EQUIPMENT LOCATIONS, ORIENTATIONS. SIZES. ETC. AND AVAILABILITY FOR REUSE. THIS INFORMATION SHALL BE VERIFIED AND CHANGED AS REQUIRED TO ADEQUATELY PROTECT THE INCOMING FEEDER TO THE SPACE - FIELD VERIFY AND CONTACT THE LANDLORD CONCERNING ANY REQUIRED REPLACEMENT OF OVERCURRENT AND /OR FEEDER AS REQUIRED. COORDINATE WITH THE LANDLORD ANY REQUIRED WORK AT THE DISTRIBUTION CENTER TO ENSURE COMPATIBILITY AND ACCEPTABILITY FOR REUSE OF SERVICE AND EQUIPMENT AS REQUIRED AND INDICATED. IF ANY ISSUES ARISE WITH REGARD TO REUSE OF SERVICE AND EQUIPMENT. CONTACT ARCHITECT AND /OR ENGINEER PRIOR TO BID FOR DISPOSITION. BASE BID SHALL INCLUDE ALL REQUIRED WORK AT LANDLORD'S DISTRIBUTION CENTER AND SHALL BE COMPLETE IN EVERY ASPECT AS REQUIRED TO ACCOMODATE THIS INTENT. NO EXTRAS WILL BE ALLOWED FOR WORK NOT INCLUDED IN BASE BID. 5. THE INTENT OF THE WORK WITH REGARD TO ELECTRICAL DISTRIBUTION AS INDICATED ON THE DRAWINGS AND IS AS FOLLOWS: A. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. VERIFY SIZE, LOCATION AND WIRING REQUIREMENTS FOR ALL EXISTING EQUIPMENT WHICH WILL REMAIN IN PLACE AND NEW PROPOSED EQUIPMENT. REPORT ANY DISCREPANCIES TO ARCHITECT FOR DISPOSITION. 8. REUSE AU. EXISTING ELECTRICAL EQUIPMENT CURRENTLY BEING USED TO FEED UGHTING. EQUIPMENT. HVAC SYSTEMS. ETC. BASE BID SHALL INCLUDE A DETAILED FIELD INSPECTION OF THE EXISTING EQUIPMENT TO DETERMINE ITS CONDITION AND COSTS TO PERFORM MAINTENANCE SERVICE ON EXISTING EQUIPMENT AS REQUIRED TO GUARANTEE PROPER OPERATION. CONSISTING OF, BUT NOT UNITED TO, THE FOLLOWING: 1. CHECK FOR AND COVER BARE WIRING. REPLACE IF REQUIRED. 2. CHECK CONDUITS FOR PROPER INSTALLATION. LE. TIGHT CONNECTIONS. PROPER FITTINGS. RUSTING. CREASING. BENDING. ETC. REPAIR OR REPLACE AS REQUIRED. 3. CHECK FOR PROPER GROUNDING OF SYSTEM AND EQUIPMENT_ CORRECT AS REQUIRED. 4. CHECK FOR CIRCUIT OVERLOADING AND /OR TRIPPING_ REPLACE BREAKERS AND /OR FUSES AS REQUIRED. REDISTRIBUTE CIRCUITDNG OF EQUIPMENT AND /OR LIGHTING AS REQUIRED. 5. CHECK ENTIRE INSTAUATION FOR CODE COMPLIANT CLEARANCES. MODIFY INSTALLATION AND EQUIPMENT LOCATIONS AS REQUIRED. 6. FIELD VERIFY AVAILABLE FAULT CURRENT AND ADJUST ALL EQUIPMENT AS REQUIRED TO PROPERLY PROTECT ALL BRANCH CIRCUITS AND EQUIPMENT. 7. CHECK FOR PROPER OVERCURRENT PROTECTION. ADJUST AND /OR REPNJVCE AS REQUIRED. 8. REPAIR ANY RUSTED AREAS ON EQUPIMENT CASINGS_ REPAINT AS REQUIRED. 9. FIELD VERIFY THE SIZES OF THE EQUIPMENT AS SHOWN AND CALLED FOR IN PLAN (REQUIRED SIZES) - IF EQUIPMENT IS NOT SIZED AS REQUIRED, CONTACT THE ARCHITECT FOR DISPOSITION. C. AS REQUIRED - SUBMIT AN ALTERNATE PROPOSAL ACCOMPANYING BID TO REPLACE ANY AND /OR ALL EXISTING EQUIPMENT, WHICH WILL BE CONSIDERED BY ALL INTERESTED PARTIES IF THE EQUIPMENT IS DETERMINED TO BE IN NEED OF REPLACEMENT AFTER THE INITIAL INSPECTION AT THE JOB SITE. ALTERNATE PROPOSAL SHALL BE COMPLETE. INCLUDING EQUIPMENT. LABOR. RIGGING COSTS (AS REQUIRED). ETC. 6. CONNECT AND RECONNECT ALL NEW AND EXISTING CIRCUITS TO PANEL AS REQUIRED. CIRCUIT NUMBERS SHOWN ON THE DRAWINGS ARE FOR INFORMATION ONLY. CONTRACTOR SHALL REUSE ALL EXISTING CIRCUITING AS REQUIRED AND CONNECT NEW CIRCUITS TO OPEN BREAKERS. ANY WORK PERFORMED ASIDE FROM THAT SHOWN. INDICATED OR IMPLIED MUST BE APPROVED BY THE PROJECT MANAGER AND /OR ENGINEER BEFORE STARTING. ALL UNUSED CIRCUITS SHALL BE UTILIZED AS SPARES. 7. REMOVE EXISTING PANEL DIRECTORY AND FURNISH AND INSTALL A NEW TYPEWRITTEN PANEL DIRECTORY. CYAN ALL MARKINGS. ETC., FROM PANEL FRONTS. 8. VERIFY SIZE. LOCATION AND WIRING REQUIREMENTS FOR ALL EXISTING EQUIPMENT CALLED FOR ABOVE. WHICH WILL REMAIN IN PLACE AND /OR BE RELOCATED. IF OUSTING EQUIPMENT IS NOT AS INDICATED ON THE DRAWINGS. CONTACT THE ARCHITECT FOR DISPOSITION PRIOR TO BID. 9. EXISTING A.C. UNFT /SYST M SHALL REMAIN IN PLACE AND BE REUSED. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING HOW UNIT /SYSTEM IS POWERED MD FOR PROPER INSTALLATION OF ALL REQUIRED OVERCURRENT PROTECTION AT UNIT/SYSTEM (I.E. DISCONNECT SWITCHES. FUSES. ETC.). WIRING. CONDUITS. ETC. AS REQUIRED BY ALL APPLICABLE CODES. ANY DEFICIENCIES DUE TO FAULTY INSTALLATION. IMPROPER INSTALLATION. CORROSION. LACK OF PROPER OVERCURRENT PROTECTION. ETC. AND REQUIRED CORRECTIONS SHALL BE FIELD VERIFIED BY AND BE THE RESPONSIBIUTY OF THE ELECTRICAL CONTRACTOR_ ANY CHANGE IN POWER REQUIREMENTS OR SERVICE TO THE AC. UNIT/SYSTEM. DUE TO SAID DEFICIENCIES. SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR AND SHALL BE COMPLETE 114 (WRY RESPECT AS REQUIRED TO ACCOMMODATE THE REMODEL 10. TELEPHONE SERVICE TO THE SPACE IS EXISTING. CONTACT THE TELEPHONE COMPANY TO ARRANGE FOR ANY CHANGE IN TELEPHONE SERVICE. FURMSH AND INSTALL ALL ADDITIONAL CONDUIT REQUIRED IN THE SPACE. 11. IF THE EXISTING TELEPHONE TERMINAL BOARD IS NOT ADEQUATE FOR THE NEW INSTALLATION. PROVIDE A NEW BOARD. NEW TELEPHONE TERMINAL BOARD SHALL BE IT X 24' PLYWOOD, 3/4' MACK, MOUNTED ON WALL, READY TO RECEIVE TELEPHONE EQUIPMENT. 12. TEMPERATURE CONTROL, INCLUDING WIRING. IS EXISTING TO REMAIN IN LOCATION SHOWN ON THE DRAWINGS. 13. SEE ARCHITECTURAL DRAWINGS FOR UGHT FUTURE SCHEDULE. EXACT LOCATION OF CEIUNG GRID. LIGHT FIXTURES. ETC. a • MECHANICAL EQUIPMENT AND MATERIAL CEILING DIFFUSER: SEE AIR DEVICE SCHEDULE. RETURN AIR REGISTER: SEE AIR DEVICE SCHEDULE. DUCTWORK: RIGID: GALVANIZED SHEET METAL, IN ACCORDANCE WITH ASHRAE AND SMACNA REQUIREMENTS FOR LOW PRESSURE DUCTWORK (1' WC). FLEXIBLE OF USED): WIREMOLD TYPE WCK OR EQUAL FLEXIBLE CLASS 1 AIR DUCT, METAUZED POLYESTER FILM LAMINATED ON STEEL WIRE REINFORCING, WITH 1.5" THICK, 3/4 LB DENSITY FIBERGLASS INSULATION AND FIRE RETARDENT REINFORCED VAPOR BARRIER (HI-VINYL) AND SHALL MEET NFPA 90A AND UL STANDARD 181. MECHANICAL WORK NOTES 1. THE SPACE IS EXISTING AND HAS PREVIOUSLY BEEN OCCUPIED. REMOVE ALL EQUIPMENT. DUCTWORK. PIPING, DIFFUSERS, ETC., NOT REQUIRED FOR THE NEW INSTALLATION. 2. FURNISH AND INSTALL NEW DUCTWORK, DIFFUSER AND REGISTER AS SHOWN AND CALLED FOR IN NEW ELECTRICAL ROOM. FURNISH AND INSTALL VOLUME DAMPERS AT NEW BRANCH TAKEOFF. FURNISH AND INSTALL PROPER ACCESS (ACCESS PANELS) TO ALL VOLUME DAMPERS AND OTHER RELATED COMPONENTS TO MECHANICAL SYSTEMS AS REQUIRED BY THE MALL. LOCAL AUTHORITIES AND ALL APPUCABBE CODES AND ORDINANCES. 3. ASIDE FROM THE NOTES ABOVE, NO NEW MECHANICAL WORK IS PROPOSED OR REQUIRED BY THIS CONTRACTOR UNDER THIS PERMIT, CONTRACT, ETC. TENANT IS ACCEPTING THE MECHANICAL SYSTEM AS INSTALLED BY THE LANDLORD. PLUMBING EQUIPMENT AND MATERIAL DRINKING FOUNTAIN (81- LEVEL): HALSEY TAYLOR IHTSEBP. WALL HUNG, HANDICAPPED TYPE. MOP SINK: FIAT #FL. -1 , 23" X 22" X 13'. MOLDED STONE SINK. COMPLETE WITH MODEL #A -1 FAUCET WITH SWING SPOUT. DRAIN, P -TRAP AND BAKED ENAMEL LEGS. PIPING MATERIALS: DOMESTIC WATER: TYPE L HARD TEMPER COPPER WITH WROUGHT SWEAT FITTINGS. WASTE AND VENT: STANDARD WEIGHT CAST IRON WITH NO -HUB FITTINGS. PIPE INSULATION: DOMESTIC WATER: 1' THICK, 3/4 LB. DENSITY FIBERGLASS WITH VAPOR BARRIER JACKET. PLUMBING WORK NOTES 1. THE EXISTING TOILET ROOM WILL REMAIN IN PLACE AND BE MODIFIED FOR HANDICAPPED ACCESS. RELOCATE EXISTING LAVATORY TO NEW LOCATION AS SHOWN AND CALLED FOR. 2. FURNISH AND INSTALL NEW FUTURES TO THE LOCATION SHOWN. CONNECT WATER, WASTE AND VENT PIPING TO EXISTING PIPING AND EXTEND TO NEW FIXTURE LOCATIONS. 3. CAP ALL EXISTING PIPING, ETC.. WHICH WILL REMAIN IN PLACE BEHIND NEW WALL OR CEIUNG FINISHES. EXPOSED PIPING WILL NOT BE PERMITTED. 4. CUT AND PATCH THE FLOOR AS REQUIRED TO INSTALL NEW WASTE PIPING. IF REQUIRED. ELECTRICAL WORK NOTES - GENERAL 1. THE ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. 2. ELECTRICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 3. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED MID SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 4. ELECTRICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 5. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. AT NO TIME SHALL ANY WORK BE UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST OCCUR AFTER REGULAR BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE. 6. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS. OMMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK. OR, FAILING SUCH NOTICE. SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 7. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 8. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER /ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS. EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 9. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS. FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 10. WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR MI EQUIPMENT FURNISHED UNDER THE CONTRACT. 11. ALL WIRE SHALL BE COPPER. MINIMUM SIZE 112 AWG. ALL CONDUCTORS #10 AND SMALLER SHALL HAVE TYPE "THHM INSULATION. CONDUCTORS LARGER THAN #10 SHALL HAVE TYPE "111W' INSULATION. 12. ALL WIRE SHALL. BE IN CONDUIT AND SHALL BE CONCEALED FROM VIEW. EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES PARALLEL WITH OR PERPENDICULAR TO COLUMN UNES OR BEAMS AND SHALL BE SEPERATED BY AT LEAST 3' INCHES FROM DOMESTIC WATER UNES WHENEVER ALONG SIDE OR ACROSS SUCH UNES. ROMEX IS NOT PERMITTED. FLEXIBLE CONDUIT OR TYPE MC CABLE MAY BE USED FOR FIXTURE AND EQUIPMENT CONNECTIONS ONLY, AND WHERE SO USED SHALL BE GROUNDED WITH A SEPERATE FULL SIZED GREEN GROUNDING CONDUCTOR. FLEXIBLE CONDUIT CONNECTIONS SHALL BE UNITED TO 3' -01' IN LENGTH. CONDUIT EXPOSED TO WEATHER SHALL BE RIGID. ALL OTHER CONDUIT SHALL BE EMT. CONDUIT FITTINGS SHALL BE COMPRESSION OR THREADED TYPE, USE OF SET SCREW FITTINGS IS NOT ACCEPTABLE. 13. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED. 14. HOME RUNS OVER 100' IN LENGTH SHALL BE 110 WIRE. 15. CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION IN ACCORDANCE WITH N.E.C. ARTICLE 110-26 AND THAT ALL REQUIRED OPERATING AND MAINTENANCE CLEARANCES ARE MAINTAINED AND ACCOUNTED FOR. ADJUSTMENTS TO LAYOUT SHOWN TO ACCOMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH ARCHITECT AND /OR ENGINEER SO AS TO MINIMIZE IMPACT ON OTHER SYSTEMS. CONTACT ARCHITECT AND /OR ENGINEER FOR DISPOSITION. 16. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND BRANCH DEVICES AS REQUIRED. 17. SEAL ALL PENETRATIONS THROUGH WALLS. CEILINGS, FLOORS. ETC. SO THAT THEY ARE AIR. WATER AND FIRE TIGHT. 18. PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS. 19. UGHTING CIRCUITS WHICH ARE SWITCHED AT PANELS SHALL BE FITTED WITH TYPE "SWO BREAKERS SUITABLE FOR SWITCHING SERVICE. 20. FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORY(IES). IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. FURNISH AND INSTALL AN ENGRAVED NAMEPLATE ON THE WALL ABOVE THE SINGLE RECEPTACLE IN THE REAR AREA FOR HANDHELD STEAMER IDENTIFYING if AS SUCH. 21. FURNISH TWO (2) COPIES OF THE ELECTRIC RISER DIAGRAM AND PANEL DIRECTORY(1ES) TO THE TENANT FOR REVIEW AND APPROVAL, OR SUBMIT A LETTER TO THE TENANT CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 22. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 23. FURNISH AND INSTALL PANEL LOCKS WHERE SHOWN ON THE DRAWINGS. 24. WIRE EMERGENCY BALLAST AND BATTERY LIGHTS ON SAME CIRCUIT IN AREA AND AHEAD OF LOCAL SWITCHING. 25. EXTERIOR SIGNAGE WLLL BE FURNISHED AND INSTALLED BY SIGN CONTRACTOR (EXISTING SIGNAGE MAY BE REUSED - VERIFY WITH ARCHITECT). CONNECT TO SIGNS AND PROVIDE POWER AS REQUIRED FOR A COMPLETE INSTAL.LATiON. COORDINATE THIS PORTION OF THE WORK WITH SIGN CONTRACTOR AS REQUIRED. 26. FURMSH AND INSTALL ALL NEW UGHTING FIXTURES AS SHOWN MID CALLED FOR. PROCURE ALL LIGHTING FIXTURES FROM LIGHTING SUPPLIER AND INSTALL THEM IN THE LOCATIONS SHOWN AS REQUIRED. CONTACT THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING A PROPOSAL TO DETERMINE WHICH FIXTURES (IF ANY) MIGHT BE FURNISHED BY THE OWNER. INSTALL ALL FUTURES (OWNER FURNISHED. IF ANY, AND CONTRACTOR FURNISHED) AS REQUIRED FOR A COMPLETE INSTALLATION. LEAVE PROTECTIVE COVERING /FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL LIGHTING FIXTURES IN RATED CEILING SO AS TO MAINTAIN INTEGRITY OF RATING. REPLACE ANY LAMPS THAT HAVE EXPIRED DURING CONSTRUCTION AND MAKE ALL ADJUSTMENTS TO FIXTURES FOR DIRECTION AS REQUIRED PRIOR TO COMPLETION. 27_ SWITCHES, NOT OTHERWISE CALLED OUT, SHALL BE MOUNTED 4' -6' ABOVE FLOOR. 28. RECEPTACLES AND TELEPHONE OUTLET'S IN SALES AREA SHALL BE MOUNTED AT 18' A.F.F. UNLESS NOTED. RECEPTACLES AND COVERS SHALL BE AS CALLED FOR IN THE SPECIFICATIONS. 29_ ALL COVERPIATES FOR ALL DEVICES SHALL BE AS REQUIRED TO MATCH ADJACENT FINISHES - COORDINATE WITH ARCHITECT. 30. VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH MID INSTALL OUTLET BOXES. DEVICES. COVERPLATE'S AND FLANGES AS REQUIRED. 31. IG AND GA RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPICED BETWEEN THE DEVICE AND THE PANEL GROUND BUS. 32. MOUNTING HEIGHTS OF EQUIPMENT NOT SPECIFICALLY CALLED FOR ARE NOTED ON ARCHITECTURAL DRAWINGS - SEE ARCHITECTURAL DRAWINGS TO COORDINATE.MEKIS 33. SUPPORT ALL FIXTURES ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL CEILING TILES OR PLASTER CLUNG SUPPORT ANY FUTTURES. 34. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF CEILING GRID. UGHT FIXTURES. ETC. AND SYMBOLS UST, FIXTURE SCHEDULE. NOTES AND OTHER SPECIFICATION REQUiONTS. 35. SPEAKERS AND RELATED WIRING WILL BE FURNISHED BY OWNER'S SUPPLIER AND SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. SPEAKER LOCATIONS ARE SHOWN ON THE DRAWINGS. CONTACT THE PROJECT MANAGER AND /OR ARCHITECT FOR MORE INFORMATION ON THIS PORTION OF THE WORK. 36. FURNISH AND INSTALL SWITCHES N SALES AREA FOR LOCAL LIGHTING CONTROL IN STRICT ACCORDANCE WITH ECC 2000 STANDARDS WITH GEORGIA AMEDUEINTS, FOR 81- LEVEL SWITCHING. MOUNT SWITCHES IN AREA SERVED AS INDICATED ON THE DRAWING. FURNISH AND INSTALL LABELS ON SWITCHES AS REQUIRED TO IDENTIFY CIRCUITS BONG SIIMRCHED. LABELS SHALL BE PERMANENTLY AFFIXED TO COVER 37_ FURNISH AND INSTALL TIMECLOCICS AND CONTACTORS TO SERVE ALL LIGHTING CROATS AS REQUIRED TO SATISFY THE IECC 2000 INCUUOING REFERENCE TO ASHRAE 90.1- 1999. REQUIREMENT FOR AUTOMATIC SHUTDOWN OF LIGHTING AS REQUIRED. MOUNT TIUECLOCKS AND CONTACTORS ADJACENT TO LIGHTING PANEL AS SHOWN AND CALLED FOR. CONTACTOR CONTROL SWITCHES OF APPLICABLE) SWILL BE INSTALLED N LOCATION SHOWN AND CALLED FOR FURNISH AND INSTALL LABELS ON SWITCHES AND CONTACTORS AS REQUIRED TO IDENTIFY CIRCUITS BEING SWITCHED. LABELS SKILL BE PERMANENTLY AFFIXED TO COMER PLATES. 38_ WORK FOR THE MN4P ERS AREA (DESK OR OFFICE) SHALL BE AS INDICATED ON THE DRAWINGS. ALL IG QUAD RECEPTACLES, RIM JACKS AND RJ-45 JACKS SHALL BE BY THE ELECTRICAL CONTRACTOR FUMESH AND INSTALL ALL JUNCTION BOXES FOR QUAD RECEPTACLES AND DATA JACKS AT HEIGHTS eCICATED. FURNISH ALL DATA JACKS WITH PURL STRING TO ABOVE THE CEILING MO TERMINATE. ALL COMPUTER WNRi1IG AND MUM WILL BE BY THE OIrNERS EQUIPMENT SUPPLIER. CONY/4C' !BM FOR COORDINATION OF INSTALLATION AS REQUIRED) 39. WORK SHALL INCLUDE STARTUP OF ML SYSTEMS, FlJRMSIE NG OF OPERATING AND MIANTE LANCE INSTRUCTIONS,, AND ONE YEAR GUARANTEE. COMMENCING NCING ON DATE OF ACCEPTANCE BY THE TENANT. 40. FURNISH ILL MATERNAL AND EQU PtENT AS SPECIFIED. EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE MUM_ 41. PROPOSAL. SHALL BE BASED ON SPECIFIED WATEREAL AND EQUIPMENT. WI ORDER TO PROMOTE COMPETITION. HCMIEVER, MDOERS ARE ENCOURAGED TO SUBMT ALTERNATE PROPOSALS ON MY ALTERNATE MATER MS AND/OR EQUIPMENT TM WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERI!NATE & 42. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMON SHALL SE INCLUDED WI THE ALTERNATE PROPOSAL 43.. N.TETRHNATE PROPOSALS HILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. No CtIAANGES W 1U. BE ALLOWED AFTER THE CONTRACT 6 SIGNED. i • COAT. ELECTRICAL WOR NOTES - GENE 44. UPON COMPLETION OF WORK, PREPARE LIGHTING AND POWER PROJECT RECORD AS- MILTS. PRESENT THE COMPLETED DRAWINGS TO THE OWNER. AS -BUILT DRAWINGS SHALL INCLUDE ALL BRANCH CIRCUIT WORK. ANY PANELBOARD INFORMATION. FINAL SWITCHING. ETC. 45. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBUES SHALL BE FIRE PROOFED TO THE SAME OR GREATER RATING THAN THAT OF THE ASSEMBLY. WHERE CONFLICT OCCURS. NOTIFY THE 46. ALL FUSES 600 AMPEREES R SHALL. BE UL LISTED. CLASS RK1 OR J. LOW - PEAK, DUAL ELEMENT, TIME DELAY, 600 VOLT. ACCEPTABLE MANUFACTURES ARE SUSSMAN. GOULD OR SHAWMUT. 47. VERIFY LOCAL CONDITIONS AT SITE. 48. COMPLY WITH ALL APPLICABLE CODES. 49. SECURE AND PAY FOR ALL REQUIRED PERMITS MECHANICAL/PLQMBING VI[QRK NOTES - GENERAL 1. MECHANICAL WORK SHAM BE COMPLETE IN EVERY DETAIL MD ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED. SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 3. MECHANICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 4. ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 5. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS. ETC. SO THAT THEY ARE AIR. WATER AND ARE TIGHT. 6. FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, ARE DAMPERS, PIPING VALVES. CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 7. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EACH FIXTURE. FURNISH AND INSTALL AN ACCESSIBLE SERVICE VALVE ON ALL BRANCH PIPING. 8. FURNISH AND INSTALL CHAMBER SHOCK ABSORBERS AS SHOWN TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. 9. NOT USED. 10. FURNISH AND INSTALL ALL PIPE HANGERS. CARRIERS, SADDLES. AND SUPPPOTS TO PROPERLY SUPPORT AND PROTECT ALL PIPING IN THE SPACE AS REQUIRED. HANGERS FOR HORIZONTAL PIPING WHERE PIPING IS TO BE INSULATED BE LARGE ENOUGH TO PASS INSULATION AND SHALL BE ELCEN FIG. 12 CLEVIS TYPE, WITH MEANS FOR VERTICAL ADJUSTMENT. INSTALL HANGERS AS FOLLOWS: PIPE SIZE HANGER ROD SIZE MAXIMUM SPACING I /2" TO 1" 3/8" 8' -0r O.C. 1 -1/4' TO 2" 3/8' 1O' T O.C. 2 -1/2" AND ABOVE 1/t 10' -0" O.C. 11. VERIFY LOCATION, DEPTH AND SIZE OF EXISTING SANITARY SEWER AT SITE. CONNECT AS REQUIRED. SEWER SHALL BE INSTALLED WITH 1/4" PITCH PER FOOT AND OUTSIDE SEWER SHALL BE INSTALLED WITH MINIMUM OF 3' -CO" COVER. 12. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 13. ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 14. FURNISH AND INSTALL TRAP PRIMERS ON ALL FLOOR DRAINS. 15. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED. EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 16. PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE. INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 17. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL 18. ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT. ENGINEER OR OWNERS REPRESENTATIVE. 19. VERIFY LOCAL CONDITIONS AT SITE. 20. COMPLY WITH ALL APPLICABLE CODES. 21. SECURE AND PAY FOR ALL REQUIRED PERMITS. 22. SEE REFLECTED CEIUNG PLAN FOR EXACT LOCATION OF CEILING GRID. UGHT FIXTURES. ETC. 23. ALL INSULATION MATERIALS, INCLUDING, BUT NOT UNITED TOO DUCT INSULATION AND PIPING INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. 24. DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMILAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONOITS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A -234. MECHANICAL WORK NOTES - AIR FILTERS 1. ON THE DAY OF STORE CONSTRUCTION COMPLETION/TURNOVER, THE AIR CONDITIONING EQUIPMENT FILTERS, IF ANY, (WHETHER NEW CONSTRUCTION OR EXISTING) SHALL BE REPTACEO WITH NEW FILTERS. irfrO 11 P 2.3 SPE C I RCATION3 7 ISSUED: 11/22/06 REVISIONS: NO. DATE: DESCRIPTION: 06-034 Job No. PNroj. Mgr. F • h a ac cc w co cc z OD Urn O < U3 I- a�� 4 1 cc N a_ $2 1- Proem By DE5 Checked By U C a, • SCALE: 1/4•_i_O,. ET NUMBER: MEP -2 •