Loading...
HomeMy WebLinkAboutPermit D07-021 - WESTFIELD SOUTHCENTER MALL - SPRINT - KIOSKSPRINT CORPORATION 301 SOUTHCENTER MALL D07 -021 Parcel No.: 2623049023 Address: 301 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: SPRINT CORPORATION Address: 301 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BL , LOS ANGELES CA 90025 Phone: Contact Person: Name: KENNETH GROOMS Address: 1120 POST AV , SEATTLE WA 98101 Phone: 206 622 -8443 Contractor: Name: ARCHITECTURAL INT /CNST SRV INC Address: PO BOX 73397 , PUYALLUP WA 98373 Phone: 253 -848 -5948 Contractor License No: ARCHIIC043C1 DESCRIPTION OF WORK: INSTALLATION OF KIOSK IN SOUTHCENTER MALL. Value of Construction: $27,050.00 Type of Fire Protection: Type of Construction: doc: IBC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D07 -021 Issue Date: 02/28/2007 Permit Expires On: 08/27/2007 Expiration Date: 10/09/2007 Steven M. Mullet, Mayor Steve Lancaster, Director Fees Collected: $866.69 International Building Code Edition: 2003 Occupancy per IBC: 0019 D07 -021 Printed: 02 -28 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature The gran constructi Signature: Print Name: doc: IBC g of north sio City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us N N N Number: 0 Start Time: Volumes: Cut 0 c.y. Start Time: Private: Profit: N Private: I hereby certify that I have read and governing this work will be complie er specified herein or not. Date: Date. Permit Number: D07 -021 Issue Date: 02/28/2007 Permit Expires On: 08/27/2007 Size (Inches): 0 End Time: Fill 0 c.y. End Time: Public: Non - Profit: N Public: Steven M. Mullet, Mayor Steve Lancaster, Director permit and know the same to be true and correct. All provisions of law and ordinances � C� permit doe t presume to give authority to violate or cancel the provisions of any other state or local laws regulating rman e o w . I am authorized to sign and obtain this development pe y/ c This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -021 Printed: 02 -28 -2007 Parcel No.: 2623049023 Address: Suite No: Tenant: 301 SOUTHCENTER MALL TUKW SPRINT CORPORATION 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 1n/ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. D07 -021 ISSUED 01/24/2007 02/28/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D07 - 021 Printed: 02 -28 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. / Signature: t i I Print Name: •' I (2 el sati doc: Cond -10/06 D07 -021 Date: ordinances governing or local laws regulating Printed: 02 -28 -2007 I SITE LOCATION CITY OF TUKWI Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h ttp: / /www. ci. to kwil a. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: 941/ — 0 22 Site Address: SO t )TI4 1"0 12. Mfr LL ( To (LA Suite Number:K1DO ) Floor. 1 S T Tenant Name: S P AIN T CG .pq1 OJV KIOSK ew Tenant: 1 Yes ❑..No Property Owners Name: WESIP IELD SO n `g 1 W A ei A $1 iba Mailing Address: 633 S od"r{ CQ +A t J ' rite WA gems zip state Name: SW M1 7 T CT of Pep) Q: Appliations\onnfAppliceions On LineO -2006 - PemitApphaROndoc Revised: 9 -2006 bh -- Building Permit No. - 21'311 02-( Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. citY (For office use only) I CONTACT PERSON — who do we contact when yomr permit is ready to be issued Day Telephone: Mailing Address: State E-Mail Address: I GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) City Contact Person: Day Telephone: E-Mail Address: Fax Number y Fax Number. Zip Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E-Mail Address: Fax Number. Contractor Registration Number. Expiration Date: Company Name: W t t.L 1 44 FM. l< SOCIA S Mailing Address: I 2.0 t O s T A dE fr 1t Wd 191,° Contact Person: l<qd Nevi G Ia� S Day Telephone: 2O6 6 2 2. 844 S E -Mail Address: 1< &1J (W POLJ. COM Fax Number. ZO 1p ' 622 $ O 3 1 Company Name: Mailing Address: State Page 1 of 6 I ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record I ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record I BUILDING PERMIT INFORTION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 2 1/ 0 5 • 0 0 Existing Buildin Valuation: $ Scope of Work (please ovide detailed information): (N S Tk u-AT 14N 6r (I) Ki c s k S PA CE 1<i Do / Sa0TN -c 7rn 2 M 4 L_ L.. Will there be new rack storage? ❑ Yes x. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DMSION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ .......None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department QAAppficuionsToms- Appiieetiws on Imeu -2006 - Pamit Appicadm.doe Revised: 9-2006 ud< ❑ Other(fY) Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 2 Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck I BUILDING PERMIT INFORTION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 2 1/ 0 5 • 0 0 Existing Buildin Valuation: $ Scope of Work (please ovide detailed information): (N S Tk u-AT 14N 6r (I) Ki c s k S PA CE 1<i Do / Sa0TN -c 7rn 2 M 4 L_ L.. Will there be new rack storage? ❑ Yes x. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DMSION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ .......None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department QAAppficuionsToms- Appiieetiws on Imeu -2006 - Pamit Appicadm.doe Revised: 9-2006 ud< ❑ Other(fY) Page 2 of 6 I PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of motion amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Date Application Accepted: D AGENT: eiJNETIt C G(c+ Mailing Address: 1(2.e. p b51 A blly -I 1- Q:\licadonsWonns-AppIicions On Une\3 -2006. P nitAppladaadoe Revised: 9-2006 bh Date: I /24/07 Day Telephone: 2 tb 4 422 Weis S elo wA- Q 1 City State Zip Date Application Expires: 15.1, l 7 ( _ Staff Initials: Page 6 of 6 Parcel No.: 2623049023 Permit Number: D07 -021 Address: 301 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/24/2007 Applicant: SPRINT CORPORATION Issue Date: Receipt No.: R07 -00296 Initials: JEM Payment Date: 02/28/2007 11:50 AM User ID: 1165 Balance: $0.00 Payee: ARCHITECTURAL INTERIORS & CONSTRUCTION SERVICES, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 20212 527.04 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 522.54 000/386.904 4.50 Total: $527.04 Payment Amount: $527.04 1 71 .w,.._.. .._ doc: Receipt -06 Printed: 02 -28 -2007 Receipt No.: R07 -00098 Payee: KIOSKO INC. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: D07 -021 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/24/2007 Applicant: SPRINT CORPORATION Issue Date: Initials: JEM Payment Date: 01/24/2007 11:09 AM User ID: 1165 Balance: $527.04 TRANSACTION LIST: Type Method Description Amount Payment Check 10496 339.65 Account Code Current Pmts 000/345.830 339.65 Total: $339.65 Payment Amount: $339.65 01/24 ^7a • T 7;39=65 doc: Receiot -06 Printed: 01 -24 -2007 Project: Type of Inspection: V Address: ! A LIO 7 tS.G Y// i / 7/ Date Called: Special Instructions: Date Wanted 26I-07 Requester: Phone No: COMMENTS: 74 _ $58.00 REINSPECTION F REQUI • ED. Prior to inspection, fee mus be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: I INSPECTION RECORD Retain a copy with permit INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 20 431 - Approved per applicable codes. El Corrections required prior to approval. January 26, 2007 Kenneth Grooms William Polk Associates 1120 Post Av Seattle WA 98101 Dear Mr. Grooms: City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application # 1 Development Permit Application D07 -021 Sprint Corporation — 633 Southcenter Mall This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 24, 2007 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following department need to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning the following comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messeneer service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Enclosures File: D07 -009 P:Uennifer\Incomplete Letters\2007\D07 -021 Incomplete Ltr #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Determination of Completeness Memo Date: January 25, 2007 Project Name: Sprint Corporation Permit #: D07 -021 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide material specifications for the Kiosk. Materials shall be non combustible or fire treated materials. 2. Identify a method for securing the Kiosk to the floor. Should there be questions concerning the above requirements, contact the Building Division at 206-431 -3670. No further comments at this time. ACTIVITY NUMBER: D07 -021 PROJECT NAME: SPRINT CORPORATION SITE ADDRESS: 3 SOUTHCENTER MALL DATE: 02 -07 -07 Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: p 2.04 Buildinit Division Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete RI Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 ,,PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 11 M Fire Prevention Structural Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 02-08 -07 Not Applicable C Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 03-08-07 Approved ❑ Approved with Conditions Not Approved (attach comments) ri Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D07 -021 DATE: 01 -24 -07 PROJECT NAME: SPRINT CORPORATION SITE ADDRESS: 633 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 1 4 8t u�dinis on Pub I NIA Works � -i DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: PERMIT COORD COPY`. PLAN REVIEW /ROUTING SLIP (I Af 022( Fire Prevention Structural Incomplete pivk � Planning Division ❑ Permit Coordinator No further Review Required DATE: Not Applicable DUE DATE: 01-5-07 DUE DATE: 02-22 -07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: td jLp,( Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc \ 2 -28-02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2/61/ Plan Check/Permit Number: D07 -021 ® Response to Incomplete Letter # 1 RECEIVED ❑ Response to Correction Letter # CIIYOFTUKWIIA ❑ Revision # after Permit is Issued FEB 072007 ❑ Revision requested by a City Building Inspector or Plans Examiner PERMITCENTER Project Name: Sprint Corporation Project Address: 633 Southcenter Mall Contact Person: KelineMi G arem Summa of Revision: CA eJk3 •• d r 11-4-e k4 a d 4 Vt Sheet Number(s): AO. a, A -. I / "`'- A-5 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: t , Entered in Permits Plus or1 O 101- \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M Mullet, Mayor Steve Lancaster, Director Phone Number• 241 06 x' 9 4 4 1 2) c x License Information License ARCHIIC043C1 Licensee Name ARCHITECTURAL INT /CNST SRV INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601676445 Ind. Ins. Account Id 55861201 Business Type CORPORATION Address 1 PO BOX 73397 Address 2 City PUYALLUP County PIERCE State WA Zip 98373 Phone 2538485948 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/21/1996 Expiration Date 10/9/2007 Suspend Date Separation Date Parent Company Previous License ARCHIIC07IN6 Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #4 RLI INS CO SRS1002624 09/24/2001 Until Cancelled $12,000.00 10/09/2001 #3 RLI INS CO SRS1002624 01/01/2001 09/24/2001 $6,000.00 02/12/2001 Business Owner Information Name Role Effective Date Expiration Date ROBINSON, ROBBY J 01/01/1980 BUNDY, DIXIE SECRETARY 09/11/2003 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ARCHIIC043C 1 02/28/2007 ABBREVIATIONS VICINITY MAP .. 0 5 AFF. ABOVE FINISH FLOOR ADJ. ADJACENT ADJUST. ADJUSTABLE AHU AIR HANDLER UNIT ALT ALTERNATE ALUM. ALUMINUM B.O. BOTTOM OF B.P. BUILDING PAPER BLDG. BUILDING CB CATCH BASIN CJ CONTROL JOINT CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASORY UNIT CONC. CONCRETE CONT. CONTINUOUS COR CORRUGATED CORR CORRIDOR CT TT CERAMIC TILE DBL DOUBLE DET DETAIL D IA DIAMETER DIM DIMENSION DN DOWN EA. EACH EIFS EXTERIOR INSULATION FINISH SYSTEM EJ EXPANSION JOINT EL EC ELECTRICAL EQ EQUAL EXT. EXTERIOR FF. FINISH FLOOR FIG. FURNISHED 4 INSTALLED BY CONTRACTOR FIN FINISH FIN. GRD. FINISHED GRADE FLOUR. FLOURESCENT F.O. FACE OF F.O.F. FACE OF FINISH F.O.I.C_ FURNISHED BY OWNER, INSTALLED BY CONTRACTOR G.L. GLUE -LAM GA GAUGE GUJB GYPSUM G YPSUM ZED GWB WALL BOARD 141 1 HOLLOW METAL H ORZ. HORIZONTAL HVAC HEATING VENTILATION AND AIR CONDITIONING INSUL INSULATION INT. INTERIOR INTERN_ INTERMEDIATE LT LIGHT MANUi =. MANUFACTURER MAT ?L MATERIAL MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MECH MECHANIC AL MIN MINIMUM MTL. METAL N.I.G. NOT IN CONTRACT O.G. ON CENTER O.1-i_ OVERHEAD of OVER OPT. OPTIONAL PLAN. PLASTIC LAMINATE PLUMB PLUMBING PT PAINT FWD PLYWOOD QT QUARRY TILE R RADIUS RECT. RECTANGULAR REQ ?D. REQUIRED RESID_ RESIDENTIAL RO. ROUGH OPENING RO.LU. RIGHT OF WAY 5.O_G. SLAB ON GRADE S_S_ STAINLESS STEEL SF SQUARE FEET/ FOOT S. SIMILAR STRJCT ?L STRUCTURAL T.O. TOP OF TYP_ TYPICAL :.`NO 111 ESS NOTED OTHERWISE V.B. VAPOR BARRIER YER T . VERTICAL viF VERIFY N FIELD W.R W ATER- RE5I5TANT W/ 'IA TI Etc LOOCD ---� ii, 5 N •• f w 0 _ sT.___---1 LE 50;r ICI NTI__R MALL t - me I ° ■ 1 4 IINE 00 � o <ILA ' - _ ~ � �❑ I i II t 1 M1111 � C LOCATION KIOSK CODE INFORMATION DRAWING INDEX OCCUPANCY: M PROJECT TYPE: Tenant improvement CONSTRUCTION TYPE: Type II -N sprinkled AREA OF IMPROVEMENT: See plans CONSTRUCTION COST: SPRINKLER SYSTEM: Existin s s tem g y MECHANICAL SYSTEM: Existing system ELECTRICAL SYSTEM: Existing system STRUCTURAL SYSTEM: Existing system GOYERN1NCz AGENCY: City or t Tukwila D y artment of Communit y Development Building Division 6300 Southcenter Blvd_ Tukwila WA 98188 tel: 206.431. fax: 206. 431. 3665 ARCHITECTURAL: -- --- 0 TITLE✓ SHEE A5.I DETAILS SHEET A52 DETAILS SHEET A53 DETAILS SHEET A5.4 DETAILS SHEET SHEET M A5.4 R�«f 1C� CC � {� ` �O�E,'LlatsC� � C �� " "`'`" "'� F l fi ?_ 6 ?C�� -- . , f ;,,1 .. �� D !I t `'i �. ,� --J STRANGER BLVD. PILE p ■` pan review approval is subject to anal and Approval of • – ... dalanenb does not the . • f: ./ a. , aooep■ed .. , a ■ rv.� [ I f. iG of � . � . _. .� ; admix i BY =� !.��i , Al �i Ob 111/7/014 minim authorise Receipt II } \ - 518 405 A. `�' B. C. � T,--,,,,,41 I ° '�► ` m j r 5 I a` r / `� \� TUKWILA PKY W i• ANDOVER PARK ' % � ' Imo`-, STRANDER BLVD — — I T PK Y ( LOCATION OF KIOSK KIOSK: Sprint Corporation SIZE: 1 x 10 MALL NAME: 5outhcenter Mall, Tukwilla (Seattle, WA) SPACE: K5008 City Of WADING DIVISION SEPARATE lT PATE: January 11, 2001 NORDSTROM VICTORIA'S SECRET PROJECT DIRECTORY a ~g�'�° Mb 0 Mechanical elBectriad SITE ADDRESS: Southcenter Mall Ti wila, Washington 9.8188 tel: 206- 656. 6001 O.INER's REP: Kiosk° 36 Precision Dr_ Suite 100 I North Spriengfield, VT 05150 t el: 802 . 8 863030 Erin Csrenier D numbing 0 Oa Piping Cdy or womb BUILDING D 1VI SION 15' -6" J { t! rages i the scope bs aesds p r.:-.7: ar.' bwt Prior 1 a _ ..� i� p a .. ::..- i v:..:.2 „ � _: t - _..-, ca t quire a ra�:� g; a s::` - r_l i zdabonal ET '� ,� 1 �� GOD IVA , - PALM ` ' ^ - S" 20' - 0" 4 •.. —_ 1\ 1 f l l l l 1 1 f f TREE nj ` �� Imo 14' -0" I R�;.� .: I�NCC ti+PL m r : 70.. L i f , - PER-: ' 021 CORRDOR JLEI JEUELERS • • • • • • • CONSULTANT REVISIONS NO DESCRIPTION DATE JOB NUMBER DATE 01001 01/0212001 PROJECT DIRECTOR DESIGNED BY DRAIN BY DMM APPROVED SCAM AS NOTED PROJECT TITLE SPRINT KIOSK OUTH CENTER " !L 1 , • POtx STATE OF WAS:il!w10:: I fE Gf Trn _�,�Sf c cD J1:1L !• f; TITLE SHEET COY REVIEW 2/02/01 CHECKED BY GRADE Darala<e• FR Particleboard �p�y�� f ICKNESS (hn) - i I 1*- 1i SPECIFICATION CLASS I FRAME SPREAD DENSITY (War R) 45 44 NOR (psi) 1.600 1.600 MOE (psi) 300.003 250.000 PATERNAL BOND (psi) 80 60 FACE SCREW HOLD (b) 250 250 EDGE SCREW HOLD (b) 225 175 UNEAR EXPANSION (%) 0.40 0.35 THICKNESS TOLERANCE (en) +:.005 +I- .005 and WIDTH (n) + T +1-N ! LEKGHT - SQUARENESS (n) +1 i +/ is Pais List ITEM PART NUMBER QTY DESCRIPTION 1 OEMA100 2 SPRINT DRAWER STORAGE i 2 ,GEMF100 1 SPRAT =OLE STORAGE 3 'GEMD100 2 SPRAT POS CABINE 4 GEMS X00 2 SPRAT SHOWCASE 5 OEMC100 f SPRAT SLAIWALL SHOWCASE 6 GEME100 1 SPRINT TRASH CAB 7 GE.NH103 I TOP - POS -TRASH I 8 GEMH104 1 TOP - SLATSHOW t • in i - T i' 31 %6 - KIOSK PLAN & ELEVATIONS semi - 1 • 6 • 2' -57" 3' nn nfln nn ■ >w e e Erns n n rnI I In 10' n nfln n an n A n fl 5' -10)) 7' e e 6• 0 0 1 s" 10 i f Co • i'0 z (0 i 1 ••• t_ Il A a_ C C) r 1" 1 I • 11 %6" 1 I 3' t 6• -2 6• -6 fi 1 Duraflake* FR PARTICLEBOARD - WEYERHAEUSER APPLICABLE STANDARD TESTS - ASTM E 84 Standard Test for Surface Burning Characteristics of Building Materials - ASTM C 236 Guarded Hot Box Test - UL 723 Test for Surface Burring Characteristics of Building Materia% BUILDING CODE - BOCA Bulking Officials and Code Administrators International - ICBO: k ternaSona! Conference of Buid.ng (*vials - SBCCI: Southern Beddng Code Congress International UNOERWRITER's LABORATORIES. Inc. CLASIFIED WOOD PARTICLEBOARD SURFACE BURNING CHARACTERISTICS. UL 723 (Based on 100 for Untreated Red Oak) RAME SPREAD 20 SMOKE DEVELOPED i 25 PHYSICAL PROPERTIES ODE COM : kia:. -. FEB 2 6'6f`,J .1r �i Co of SI .1)I c }: `' ' MATERIAL 5PECrP.CATION ADDED FECEIYCD MY Cr: TLV -• ::.i. CONSULTANT REVISIONS NO CITY REvra1 JOB N'UNBER 01001 PROJECT DIRECTOR DRAIN BY APPROVED SCAME AS NOTED PROJECT 1111E PR1NT KIOSK SOUTH CENTER MEET TITIE DETAILS SHEET DESCRIPTION DATE 0110212001 DESCNED BY CHECKED BY DATE 2/02101 e a ♦ • v P Pre- insta"led Device r B 2 nn 63 1B • 1:1) Duplex Flonecent Lighting 12v LED Lighting 5Q Halogen Lighting Transformer Sil gle End Whip L L _p i Two End %Nip Junction Box 15 Amp Switch w!! Duplex Quad Receptade --€ 1 12V Plug -at transformer 2 Light Balt Box 3 Light BaNast Box 4 Light Baiast Box Sprite / Con eco' KIOSK ELECTRICAL PLAN r-,/ SCALE TO FIT a • ELECTRICAL HARNESS SPECIFICATIONS: ALL COMPONENTS UL LISTED 70A 2 CIRCUIT LOAD CENTER CABLING 12-3 MC ALL CONNECTIONS ARE UL LISTED METAL CLAD QUICK CONNECTS KIOSK POWER REQUIREMENTS: CIRCUIT 1 120V 20A CIRCUIT 2 120V 20A SEE SCHEDULE FOR FIXTURE DETAIL Ii r 82 1 ••• • Tamer VogkeEndWip P Pee ire - ed Boyce c Two End% %tip O Junction Box tS A. a SsrA n• OLcies I fl Spie-tOtraelx 0 O:ad Recepace 2V P.rp r. txrst 2t.gt Bear 3os 3 !Kett Barest 8ca _ct eaas e:a 20A Breaker ELECTRICAL Ut0I6 DIAGRostl ADDLED 20A Breaker • S UPPER RING �D E \I/ t ` L{,••J L cc v Y' - • Tve a DEP- i I CONSULTANT REVISIONS NO JOB NUMBER 01001 PROJECa DIRECTOR DRAIN BY APPROVED SCALE AS NOTED PROJECT 1111E SPRINT KIOSK Wu1'i•4 CEWTER SHEET T DESCRIPTION CITY REVED DATE 01102/2001 DESIGNED BY CHECKED BY DETAILS SHEET DATE 2102/01 • I 161 1 • • • u v 1981.00mm V ww0V99@ P —, 553.00nm /1/4` TEMPERED GLASS 553.00mm 1 % * t '1 "41 I 161 1 • • • u v 1981.00mm 16%, P —, 553.00nm 553.00mm 553.00mm 1 % * t '1 "41 • I RECE P S 0 o 0 0 0 0 0 0 0 0 0 0 0 0 u v 1981.00mm 16%, P —, 0 • _ r 'PEN DRAWER `CASHBOX SHELF — as 00mm 23S 00mm 1 il I -T1 /PRA'I'ER SHELF ' D I_ i j Lou I U111M'CC7 0 o 0 0 0 0 0 0 0 0 0 0 0 0 u v 1981.00mm 16%, 1 .w IUM 1 16C 1 WWOO'SS£ 0 • I I • 0 1828.00mm KIOSK DRAWER STORAGE SCALE TO AT YVY VUI WU. 'UV •U iUU IV VW; • r • II II I 5640Onm I 56-1 03ren ___ (1'-1V A tT -111 564.0 n 11-11 KIOSK SHOWCASE SCALE TO FIT 1828.0a1m 1 1 44' TEMPERED GLASS • 1 i 1 1 3 � N - E E o � n (3)16 WATT Ti FLUORESCENT LIGHT FOCTL..$ ALL MATERIAL 3'4' FIRE-RATED FLAKEBOARDWITH WHITE MELAMINE SECTION A-A SCALE 0.1S: 1 ALL MATERIAL 3i' FIRE -RATED FLAKEBOARD WITH NATURAL CHERRY !/ELAMAE 1r Sawn x 456 5firim 1141 SECTION A-A SCALE 0.15: 1 I • d o oO O 0 0 • • 0 915.00mm a r- ' C KIOSK ACCESORY CABINET SCALE TO FIT 131 POS CABINET A SCALE TO FIT • I A A SECTION A-A SCALE O.15: 1 SECTION A-A SCALE 0.15: 1 AU. MATERIAL 3W FIRE -RATED FLAKEBOARD WITH WHITE MELAMINE LIGHT FIXTURE WITH 6 - 20 WATT XENON BULBS • tl /6• O.C. SLATWALL E 0 ti c) E E ID 1- KIOSK TRASH CABINET SCALE TO FIT • ALL MATERIAL 314• FIRE -RATED FLAKEBOARD WITH WHITE MELAMINE • O SECTION A -A SCALE 0.18 :1 PULL-OUT WASTE BASKET pv RE re • CONSULTANT REVISIONS NO DESCRIPTION DATE JOB NUMBER 01001 PROJECT DIRECTOR DRAIN BY APPROVED sou AS NOTED PROJEICT TI1IB SPRINT KIOK WUTH CENTER swEE'T TmE DETAILS 5HEET SURE s>t A5.3 DATE 0V02l1001 DFD BY CHI BY • a • SEISMIC BRACKET KIOSK 3D ELEVATIONS SCALE TO FIT KW1K BOLT 3 EXPANSION ANCHOR WITH A 2' MIN. EMBEDMENT IN CONCRETE DETAIL A DETAIL B fii TRASH RECEPTACLE • DRAWER FOR STORAGE KEYBOARD SECURITY COVER SHOWN REMOVED KEYBOARD SECURITY COVER SHOWN IN LOCKED POSITION POS SHOWN WITH DOORS IN CLOSED POSITION POS SHOWN WITH DOORS IN OPEN POSITION r i: " - 4 = r� �L' T . 1 \_ - : r :" Ffa 2 PE- t " 21 • CONSULTANT REVISIONS NO DESCRIPTION DATE n JOB NUMBER 0100I PROJECT DIRECTOR DRAWN BT DT/1 ,PPROrTD SCAM AS NOTED PROJECT /ME CITY REVIEW 2102101 ATE OVo2flotol DESIGNED BY CHECKED BY SPRINT KIOK OUTHCENTER SHEER raiz DETAILS I4EET I a