HomeMy WebLinkAboutPermit D07-036 - DENG RESIDENCE - BATHROOM REMODEL AND PATIODENG RESIDENCE
15460 65 AV S
EXPIRED 09 - 25 - 07
D07 -036
Parcel No.: 0003200013
Address: 15460 65 AV S TUKW
Suite No:
Tenant:
Name: DENG RESIDENCE
Address: 15460 65 AV S , TUKWILA WA
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
Owner:
Name: JOHNNY DINO H +ANITA L
Address: 15460 65TH AVE S , TUKWJLA WA 98057
Phone:
Contact Person:
Name: DARWIN GARCIA
Address: 5343 140 S , TUKWILA WA 98168
Phone: 206 383 -5631
Contractor:
Name: OWNER AFFIDAVIT - PING LIN
Address:
Phone:
Contractor License No:
City of Tukwila
DESCRIPTION OF WORK:
BATHROOM REPAIR/REMODEL AND ENCLOSING FRONT PATIO
DEVELOPMENT PERMIT
Value of Construction: $6,000.00 Fees Collected: $415.62
Type of Fire Protection: International Building Code Edition: 2003
Type of Construction: VB Occupancy per IBC:
* *continued on next page **
Permit Number: D07 -036
Issue Date: 02/28/2007
Permit Expires On: 08/27/2007
Expiration Date:
Steven M. Mullet, Mayor
Steve Lancaster, Director
doc: IBC -10/06 007 -036 Printed: 02 -28 -2007
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Thee: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private:
Storm Drainage:
Street Use: Profit: N
Water Main Extension: Private:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied
Signature:
Print Name:
doc: IBC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
N
J
Permit Number: D07 -036
Issue Date: 02/28/2007
Permit Expires On: 08/27/2007
Date:
Public:
Non - Profit: N
Public:
Steven M. Mullet, Mayor
Steve Lancaster, Director
It nom 6 tilb A LQ
permit and know the same to be true and correct. All provisions of law and ordinances
r specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit.
Date: /P - s/ d 7.
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
D07 -036 Printed: 02 -28 -2007
Parcel No.: 0003200013
Address: 15460 65 AV S TUKW
Suite No:
Tenant: DENG RESIDENCE
1: ** *BUILDING DEPARTMENT CONDITIONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number: D07 -036
Status: ISSUED
Applied Date: 02/05/2007
Issue Date: 02/28/2007
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any
requirements for special inspection.
T: All wood to remain in placed concrete shall be treated wood.
8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
11: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
12: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
13: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances
shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms,
bathrooms, toilet rooms, storage closets, surgical rooms.
14: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE
GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that
the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests.
15: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum
doc: Cond -10/06
D07 -036 Printed: 02 -28 -2007
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
* *continued on next page **
distance of 4- inches shall be maintained above the controls with the strapping.
16: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
17: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248 - 6630).
18: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
D07 -036 Printed: 02 -28 -2007
Signature:
Print Name:
doc: Cond -10/06
V
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Date: 0 ) /d- a4 7.
D07 -036 Printed: 02 -28 -2007
Site Address: !' Ca ‘S7 ft i /f
Tenant Name:
Property Owners Name: \J tiA) F'tir^ DPW
Mailing Address: �. ? 3 / w9 $4 AI/8 S E
/ / City
CONTACT PERSON;= who do we contact when your permit is ready to be issu
Name: (.k u1.0 1 v` C-7q rcZet
Mailing Address: 53 43 l L(O 5.
E -Mail Address:
GENERAL CONTRACTOR INFORMATION
(Contractor Informationfor Mechanical (pg 4) for. Plumbing and Gas Piping (pg
Company Name:
Contact Person:
E -Mail Address:
Company Name:
Mailing Address:
Company Name:
Contact Person:
E -Mail Address:
CITY OF TUKWILA
Community Developmeepartment
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Contact Person:
E -Mail Address:
to (1
Q:\ Applications\FonnrApplications On Line\3 -2006 - Permit Application.doc
Revised: 9-2006
bh
King Co Assessor's Tax No.: 000,24, - 00 ( '
Suite Number: Floor:
Day Telephone: 2- 383' 5lo 31
4- (13V—W1 CI
City
Fax Number:
New Tenant: ❑ .... Yes ❑ ..No
ti44 3
State p
wet g8 1(or
State Zip
Mailing Address:
Zip
City
Day Telephone:
Fax Number:
Contractor Registration Number: Expiration Date:
State
ARCHITECT OF.RECORD
State
Zip
City
Day Telephone:
Fax Number:
Mailing Address:
Zip
State
City
Day Telephone:
Fax Number:
Page 1 of 6
Valuation of Project (contractor's bid pr ,. $ ce DOC Existing ding Valuation: $
Scope of Work (please provide detailed information): (ocf t cpo °>wt 2e ()air / Uci r bAcui 4 ilfAsvitkit
thCIOS t vL J e.Kt5+tir,, pc -to
Will there be new rack storage? 0.... Yes
Will there be a change in use?
If yes, a separate permit and plan submittal will be required.
26 F1 •
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
❑ Yes
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes [ No
If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
Compact: Handicap:
❑ No If "yes ", explain:
Page 2 of 6
Fixture Type, . ' '
Qty
'Fixture`Type.; :
Qty ;
Fixturre T e
�� "
Qty
.Fixture"T . ,.e .
yp
.
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory .
Water Closet .
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Contact Person:
E -Mail Address:
Contractor Registration Number:
Q: Applications\Porma- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
Valuation of Plumbing work (contractor's bid price): $
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information):
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
State
Zip
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Page 5 of 6
'cat'
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING O NER OR AUTHORIZED AGENT:
Signature: t)pr a DIW
Print Name: Jry / &VG DE AV
Mailing Address: ) 3 rj I t4 AV Cz Sf.
Date Application Expires:
Date Application. Accepted:
v_ttctoq—
Q:\Appliations\Fonns- Applications On Line\3 -2006 -Permit Application.doc
Revised: 9 -2006
bb
Date: 01 i <>
Day Telephone: 0e Og — 01 (/
1-3 12
eli6v 9 ., e 00 6 -
City State Zip
Staff Initials: �___- 1
Page 6 of 6
Receipt No.: R07 -00297
Initials: JEM
User ID: 1165
Payee: PING LIN
TRANSACTION LIST:
Type Method Description
ACCOUNT ITEM LIST:
Description
BUILDING - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 0003200013 Permit Number: D07 -036
Address: 15460 65 AV S TUKW Status: APPROVED
Suite No: Applied Date: 02/05/2007
Applicant: DENG RESIDENCE Issue Date:
Amount
Payment Check 2434 155.14
Account Code Current Pmts
000/322.100 155.14
Total: $155.14
Payment Amount: $155.14
Payment Date: 02/28/2007 12:21 PM
Balance: $0.00
(Inc: Rarrint -(1R Printar1 07 -2R -7007
Parcel No.: 0003200013
Address: 15460 65 AV S TUIKW
Suite No:
Applicant: DENG RESIDENCE
Receipt No.: R07 -00164
Initials: JEM
User ID: 1165
Payee: WENFENG DENG
ACCOUNT ITEM LIST:
Description
rlor.• RAmint -06
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: httx/Iwww.citukwila.wa.us
000/322.100
000/345.830
000/386.904
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Cash 260.48
Account Code Current Pmts
Permit Number: D07 -036
Status: PENDING
Applied Date: 02/05/2007
Issue Date:
Total: $260.48
Payment Amount: $260.48
Payment Date: 02/05/2007 03:27 PM
Balance: $0.00
155.14
100.84
4.50
y ./Pw. -I • IOTA'
Printer. f19 -flS -2007
Project: / )
Vbiol ec
Type of 156peRiorI„,-- N
/.4/ It y.,e,e_
Date Called:
Special Instructions:
,i,
Date Wanted
9 --(37 a
Requester:
•
Phone No:
INSP
ECION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 981 88
COMMENTS:
Inspect°
Date:3_ 2.9t 4 . 7
Approved per applicable codes. Corrections required prior to approval.
ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
1-1 paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
Date:
Project: n
Type of pection:
Address:
/5 —65
,�
`
., 9?
Date Called:
Special Instructions:
2
Date Wanted
a.m.
Requester:
j7 ;1 , – , ,44 - 7
Phone No.
Zi ---;
7
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
ni $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Project:
00f'A./ 6 ,'S .
Type of Inspection:
X A/v /V f/ue 2
Address:
/5 GS 'Iv 5
Date Called:
Special Instructions:
Date Wanted:
3 - 7- a -2
a.m.
/a.m.
Requester:
Phone No:
G /-366
INSPECTION RECORD'
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
�a 7 - c?
0
431 -3
OM MENTS:
Approved per applicable codes. ❑ Corrections required prior to approval.
Direr
El $58.bti'(2EINSPECTIOI4 REQ'IRED. Prior to inspection, fee must be
p id at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Rec it No.:
Date:
Project:
A,
Type Inspection:
,111/#1
`J
kb
Add r s:
Date Called:
Special Instr
ions:
Date Wanted:
.677
Request.
Phone No:
INSPECT 14N NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
D Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
(2 6)
Corrections required prior to approval.
COMMENTS:
Inspector,
Date37 -d7
$58.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
'Date:
444 " . : ^" r . •
s . CITY OF TUKWILA
' RESIDENTIAL BUILDING CODES CHECK LIST
D 2. = � 'ID?
Permit!
This is a list of building code requirements commonly used for most construction projects. It is not a complete list of all building and energy des.
Some conditions may require further investigation for code compliance. Building construction shall meet all the current building code requirements
t o your project. Contact your local building code official or designer for further code questions or requirements.
lib
:K APPLIC.
a:k
Where a RED arrow box is shown on the plans, the number in the box shall reference
any checked CODE REFERENCE shown in the right column and below.
CODE
REFERENCE
(2003 IRC)
REF. CODE DESCRIPTION OR REQUIREMENT
KEY
( (2 00 IMC) AN
(2004 WSEC)
Handout No.
FOUNDATION ANCHORAGE, DECKS
{DCD H###}
1
Wood sole plates that bear on concrete shall be pressure treated.
R320.3
Footing and stem walls. Where a construction joint is created between a concrete footing and stem wall, a minimum of
one No. 4 bar shall be provided at not more than 4 feet on center. The vertical bar shall extend 3 inches clear of the
bottom of the footing, have a standard hook and extend a minimum of 14 inches into the stem wall. (Monolithic pours shall
not require vertical bar in stem walls unless otherwise noted per engineering or other related design requirements)
R403.1.3
(DCD H008)
Foundation stem walls. Foundations with stem walls shall be provided with a minimum of one No. 4 bar at the top of the
wall and one No. 4 bar at the bottom of the footing.
R403.1.3.1
(DCD H008}
Wood sole plate at exterior walls shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet on
center. There shall be a minimum of two bolts per plate section and located not more than 12 inches from each end of the
plate section. Bolts shall be at least 1/2 inches in diameter and extend a minimum of 7 inches into the concrete or
masonry.
R403.1.6
Wall anchorage. Brace wall line sills shall be anchored to concrete or masonry foundations... In seismic zone D-1 and D-
2... with plate washers, a minimum of 1/4 inches by 3 inches by 3 inches in size, shall be provided between the foundation
sill plate and the nut. (2 inch square washers may be used per specific engineering recommendations and meet
requirements of the 2003 IBC.)
R602.11.1
{DCD H008}
{DCD H009}
DECKS Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure
and designed for both vertical and lateral Toads as applicable. Such attachment shall not be accomplished by the use of
toenails or nails subject to withdrawal. Where positive connection to the primary building structure cannot be verified
during inspections, decks shall be self supporting. Decks with cantilevered framing members, connections to the exterior
walls or other framing members, shall be designed and constructed to resist uplift resulting from the full live Toad specified
in Table R301.5 acting on the cantilevered portion of the deck.
R502.2.1
(DCD H012}
Ledger bolts Size and spacing - minimum 1/2 Inch bolts at 2 feet on center up to 10 foot span. See table in figure
R606.10.(1) for additional span requirements.
Figure R606.10(1)
(DCD H012)
MISCELLANEOUS FRAMING INFORMATION
2
Roofing for slope of roof: the use of asphalt shingles shall only be allowed on roofs with a minimum slope of two units
vertical in 12 units horizontal (2:12) or more.
IRC R905.2.2
Minimum area. Every dwelling unit shall have at least one habitable room that shall have not less than 120 square feet of
gross floor area.
IRC R304.1
Other habitable rooms shall have a floor area of not less than 70 square feet.
IRC R304.2
Habitable rooms dimensions shall not be less than 7 feet in any horizontal dimension.
IRC R304.3
Height effect on room areas. Portions of a room with a slopping ceiling measuring less than 5 feet or a furred ceiling
measuring Tess than 7 feet from the finished floor to the finished ceiling shall not be considered as contributing to the
minimum required habitable area for that room.
IRC R304.4
Minimum height: habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have
a ceiling height of not less than 7 feet... measured from the finish floor to the lowest projection of the ceiling.
IRC R305
INSULATION, EXHAUST VENTILATION
3
Insulation Wails =R -21, Ceilings =R -38, Vaulted ceilings or rafters =R -30, Floors =R30, Slab on grade =R -10, Walls
below grade =R -15 int. R -10 ext.
2004 WSEC
TABLE 6 -1
Roof /Celling Insulation: Open -blown or poured loose -fill insulation may be used in attic spaces where the slope of the
ceiling is not more than 3/12 and there is at least 30 inches of clear distance from the top of the bottom cord of the truss or
ceiling joist to the underside of the cord of the truss or ceiling joist to the underside of the sheathing at the roof ridge.
When eve vents are installed, baffling of the vent openings shall be provided so as to deflect the incoming air above the
surface of the insulation.
Where lighting fixtures are recessed into a suspended or exposed grid ceiling, the roof /ceiling assembly shall be
insulated in a location other than directly on the suspended ceiling.
EXCEPTION: Type IC rated recessed lighting fixtures.
Where installed in wood framing, faced bat insulation shall be faced stapled.
2004 WSEC 1311.2
Wail insulation: Exterior wall cavities isolated during framing shall be fully insulated to the levels of the surrounding walls.
When installed in wood framing, faced batt insulation shall be face stapled.
Above grade exterior insulation shall be protected.
2004 WSEC 1311.3
r
Floor Insulation: Floor insulation shall be installed in a permanent manner in substantial contact with the surface being
insulated. Insulation supports shall be installed so spacing is not more than 24 inches on center. Installed insulation shall
not block the air flow through foundation vents.
2004 WSEC 1311.4
,/
�'
Printed 2 /23/2007
Page 1 of 5
Form # DCD A100
3
Source Specific Ventilation: Source specific exhaust ventilation is required in each kitchen, bathroom, water closet,
laundry room, indoor swimming pool, spa, and other rooms where excess water vapor or cooking odor is produced. For
source specific ventilation capacity see table 3-1 2004 WSVIAC.
2004 WSVIAC
302.2.1
k/
Minimum ventilation openings for crawlspace and attic openings shall be 1 sq. foot per 150 sq. foot of space.
R408(CrawlSpace)
IRC R806.3 (ATTIC)
,/
i�
Openings for under -floor ventilation. Minimum net area of ventilation opening shall net be less than 1 square foot for
each 150 square feet of under -floor area. Openings shall be within 3 feet of each comer of the building.
IRC R408.2
/i
!�
BATHROOMS
4
Bathrooms shall be provided with aggregate glazing area in windows of not less than 3 square feet, one -half of which
must be open able.
R303.3
Exception: The glazed areas not required where artificial light and a mechanical ventilation system are provided.
Minimum ventilation rate shall be 50 cfm... vented to the outside
'/
a*'
Bathrooms shall have a minimum ceiling height of 6 feet 8 inches over the fixture and at the front clearance area for
fixtures.
R305.1
1
Bathtub and shower walls surface shall be finished with a nonabsorbent surface and extend to a height of not less than 6
feet above the floor.
R307.2
v
Mechanical Ventilation: Exhaust air from bathrooms and toilet rooms shall not be re- circulated within a residence or to
another dwelling unit.
M1506.2
Ventilation rate. Ventilation systems shall be designed to have the capacity to exhaust the minimum air flow rate
determined in accordance with Table 1506.3.
Bathrooms — Toilet Rooms Mechanical exhaust capacity of 50 cfm intermittent or 20 cfm continuous.
M1506.3
L.•••
EGRESS WINDOWS, HALLS, STAIRS, RAILINGS
5
Basements with habitable spaces and every sleeping room shall have at least one open able emergency escape and
rescue opening. Opening sill height shall be no more than 44 inches above the floor.
R310.1
Minimum clear opening shall net clear 5.7 square feet.
R310.1.1
Minimum opening height shall net 24 inches.
R310.1.2
Minimum opening width shall net 20 inches.
R310.1.3
Openings shall be open able from the inside without the use of keys or tools.
R310.1.4
6
Window wells horizontal area shall be 9 square feet with a min. horizontal projection and width of 36 inches and shall
allow emergency escape and rescue opening to be fully opened. Window wells with a vertical depth greater than 44 inches
shall be equipped with a permanently affixed ladder or steps, ladder or rungs shall have an inside width of at least 12
inches, shall project at least 3 inches out from the wall and spaced not more than 18 inches on center vertically the full
height
R310.2
7
Under stair protection. Enclosed accessible space under stairs shall have walls, under stair surface and any soffits
protected on the enclosed side with 1/2 -inch gypsum board.
R311.2.2
8
Minimum hallway width shall be 36 inches.
R311.3
9
Exit doors required: Not less than one exit door shall be required...provide direct access from habitable portions of the
dwelling to the exterior with out requiring travel through a garage.
R311.4.1
Required exit door shall be hinged, 36 inches minimum width, 6 feet 8 inches minimum height.
R311.4.2
There shall be a floor or landing on each side of each exterior door.
R311.4.3
Headroom. The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches measured vertically
form the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
R311.5.2
{DCD H011}
Stair risers. The maximum riser height shall be 7 -3/4 inches, measured vertically between leading edges of the adjacent
treads. The greatest riser height with any flight of stairs shall not exceed the smallest by more than 3/8 inches.
R311.5.3.1
(DCD H011)
Stair treads. The minimum tread depth shall be 10 Inches measured horizontally between the vertical planes of the
foremost projection of adjacent treads and at a right angle to the tread's leading edge..
R311.5.3.2
{DCD H011}
10
Profile. The radius of curvature at the leading edge of the tread shall be no greater than 9/16 inch. A nosing not less than
3/4 inch but not more than 1 -1/4 inch shall be provided on stairways with solid risers. The greatest nosing projection shall
not exceed the smallest nosing projection by more than 3/8 Inch between two stories, including the nosing at the level of
the floors and landings. Beveling of nosing shall not exceed 1/2 inch. Risers shall be vertical or sloped from the underside
of the leading edge of the tread above at an angle not more than 30 degrees from the vertical. Open risers are permitted
provided that the opening between treads does not permit the passage of a 4 -inch diameter sphere.
Exception:
1. A nosing is not required where the tread depth is a minimum of 11 inches.
2. The opening between adjacent treads is not limited on stairs with a total rise of 30 inches or less.
R311.5.3.3
(DCD H011}
Landings. There shall be a floor or landing at the top and bottom of each stairway. EXCEPTION: A floor or landing is not
required at the top of an interior flight of stairs, provided a door does not swing over the stairs. A flight of stairs shall not
have a vertical rise greater than 12 feet.
R311.5.4
(DCD H011}
Handrail height, measured vertically from the sloped plane adjoining the tread nosing , or finish surface of ramp slope,
shall be not less than 34 inches or more than 38 inches to top of the handrail.
R311.5.6 and
R 311.5.6.1
{DCD H011}
Printed 02/23/2007
Page 2 of 5
Form # DCD A100
i
1 O
Handrails shall be continuous for the full flight of the stairs.
R311.5.6.2
(DCD H011)
Porches, balconies or raised floor surfaces located more than 30 inches above the floor or grade below shall have guards
not Tess than 36 inches in height.
R312.1
(DCD H011}
,
Guard openings shall have intermediate rails or omamental closures which do not allow passage of a sphere 4 inches or
more in diameter.
R312.2
{DCD H011)
SMOKE ALARMS
11
Smoke alarms shall be installed in: each sleeping room, outside each separate sleeping area in the immediate vicinity of
the bedrooms, on each story of the dwelling including basements but not crawl spaces.
Exception: Smoke alarms in existing areas shall not be required to be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is
an attic, crawlspace, or basement available which could provide access for hard wiring and interconnection without the
removal of interior finishes.
R313.1
/ /
v
.
The required smoke alarms shall receive their primary power from the building wiring and when primary power is
interrupted, shall receive power from a battery.
R313.2
When Interior alterations , repairs or additions requiring a permit occur, or when one or more sleeping rooms are added
or created in dwellings, the individual dwelling unit shall be provided with smoke alarms located as required for new
dwellings; interconnected and hardwired.
R313.1.1
v
MECHANICAL
12
Appliances access for inspection service, repair and replacement. Appliances shall be accessible for inspection, service,
repair and replacement without removing permanent construction. Thirty inches of working space shall be provided in front
of the control side to service an appliance, Room heaters shall be allowed 18 inches working space with no platform
required.
IRC M1305.1
13
Central furnace within compartments or alcoves shall have a minimum working space of 3 inches along the sides, back
and top with a total width of the enclosing space being at least 12 inches wider than the fumace. Fumaces having a firebox
open to the atmosphere shall have at least a 6 -inch working space along the front combustion chamber side. Combustion
air opening at the rear or side of the compartment shall comply with the requirements of Chapter 17.
IRC M1305.1.1
Appliances installed In a compartment, alcove, basement or similar space shall be accessed by an opening or door and
an unobstructed passageway measuring not less than 24 inches wide and large enough to allow removal of the largest
appliance in the space, provided that a level service space of not less than 30 inches, is present at the front or service
side of the appliance with the door open.
IRC M1305.1.2
Protection from Impact. Appliances located in a garage or carport shall be protected from impact by automobiles. (2000
Ib. Impact Toad capacity)
IRC M1307.3.1
IBC 1607.7.3
Outdoor combustion air shall be provided through opening's) to the outdoors in accordance with Section G2047.6.1 or
0204.6.2 . The minimum dimension of air openings shall be not less than 3 inches.
IRC G2407.6
(304.6)
Combustion alr openings. Two permanent opening method, one commencing 12 inches from the top and one 12 inches
from the bottom of the enclosure... commencing directly by duct to the outdoors. Each opening shall have a minimum free
area of 1 square inch per 4,000 Btu/h of total input rating of all equipment in the enclosure.
IRC G2407.6.1
(304.6.1)
Appliance located In attics or crawl space shall have access openings and a clear space and unobstructed passage
way large enough to allow removal of the largest appliance, but not less than 30 inches high and 22 inches wide and not
more than 20 feet in length when measured along the center line of the passage way from the opening to the appliance.
IRC Section M
1305 IRC Section
R807
Appliance located In an enclosure in which all combustion air is taken from the outdoors and the enclosure is equipped
with a solid weather - stripped door and self - closing device.
IRC M 1701.4
Two openings or ducts. Combustion air shall be supplied through openings or ducts...connected directly to the outdoors,
such as ventilated crawl spaces or ventilated attics.
IRC M 1703.2
Elevation of Ignition source. Equipment and appliances having an ignition source and located in hazardous locations
and public garages, private garages shall be elevated such that the source of ignition is not less than 18 inches above the
floor surface on which the equipment or appliance rest. For the purpose of this section, rooms or spaces that are not part
of the living space of a dwelling unit and that communicate directly with a private garage through openings shall be
considered to be part of the private garage.
IMC 304.3
CLOTHES DRYER EXHAUST
14
Duct penetrations; Ducts that exhaust clothes dryers shall not penetrate or be located with in any fire blocking,
draftstopping or any wall, floor /ceiling or other assembly required by this code to be fire - resistance rated, unless such duct
is constructed of galvanized steel or aluminum of the thickness specified in the mechanical provisions of this code and the
fire- resistance rating is maintained in accordance with this code.
IRC G2439.2
(614.12)
Exhaust installation. Dryer exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be
equipped with a backdraft damper. Screens shall not be installed at the duct termination. Duct shall not be connected or
installed with sheet metal screws or other fasteners that will obstruct the flow. Clothes dryer exhaust duct shall not be
connected to a vent connector, vent or chimney. Clothes dryer exhaust ducts shall not extend into or through ducts or
plenums.
IRC G2439.3
(614.4)
I/
Make up air. Installations exhausting more than 200 cfm shall be provided with makeup air.
IRC G2439.4
(614.5)
Ai
Page 3 of 5
Printed 02/23/2007
Form # DCD A100
14
Clothes dryer ducts. Exhaust ducts for domestic clothes dryers shall be constructed of metal and shall have a smooth
interior finish. The exhaust duct shall be a minimum nominal size of 4 inches in diameter. The male end of the duct at
overlapped duct joints shall extend In the direction of air flow. Clothes dryer transition ducts used to connect the appliance
to the exhaust duct system shall be metal and limited to a single length not to exceed 8 feet in length and shall be listed
and labeled for the application. Transition ducts shall not be concealed within construction.
IRC G2439.5
(614.6)
Maximum length. The maximum length of the clothes dryer exhaust duct shall not exceed 25 feet from the dryer location
to the outlet termination. The maximum length of the duct shall be reduced 2 -1/2 feet for each 45 degree bend and 5 feet
for each 90 degree bend.
Where make and model of the clothes dryer to be installed is known...maximum duct length shall be permitted to be in
accordance with the dryer manufacture's Installation instructions.
IRC G2439.5.1
(614.6.1)
EXCEPTION
1/
ACCESS OPENINGS (Attics & Crawlspaces)
15
Crawlspace minimum access openings through floors shall be 18 inches by 24 inches and 16 inches by 24 inches
through a perimeter wall. Access doors shall be weather - stripped. NOTE: Access openings shall be sized to allow
installation or removal of any mechanical equipment.
IRC R408.3
Attic space access opening shall not be less than 22 inches by 30 inches and provide a minimum unobstructed
headroom in the attic access no less than 30 inches.
IRC Section R807
Appliances In attics. Attics containing appliances requiring access shall be provided with an opening and a clear and
unobstructed passageway large enough to allow removal of the largest appliance, but not less than 30 inches high and 22
inches wide and not more than 20 feet in length when measured along the centerline of the passageway from the opening
to the appliance. The passageway shall have continuous solid flooring...not less than 24 inches wide. A level service
space 30 inches deep by 30 inches where access Is required.
M1305.1.3
Appliances under floors. Underfloor spaces containing appliances requiring access shall be provided with an
unobstructed passageway large enough to remove the largest appliance, but not less than 30 inches high and 22 inches
wide, nor more than 20 feet in length when measured along the centerline of the passageway from the opening to the
appliance. a level service space at least 30 inches deep and 30 inches wide shall be present at the front or service side of
the appliance. (see code for additional information)
M1305.1.4
WEATHER PROOFING
16
Weather - resistant sheathing paper. Asphalt - saturated felt free from holes and breaks, weighing not less than 14 pounds
per 100 square feet and complying with ASTM D 226 or other approved weather- resistant materials shall be applied over
studs of sheathing of all exterior wall as required by Table R703.4. Such felt or material shall be applied horizontally, with
the upper layer lapped over the lower layer not less than 2 inches. Where vertical joints occur, felt shall be lapped not less
than 6 inches.
IRC R703.2
Flashing. Approved corrosion- resistant flashing shall be provided in the exterior wall envelope in such a manner as to
prevent entry of water into the wall cavity or penetration of water to the building structural framing components. The
flashing shall extent do the surface of the exterior wall finish and shall be installed to prevent water from reentering the
exterior wall envelope.
IRC R703.8
Concrete and Masonry Foundations Dampproofing. Foundation walls that retain earth and enclose habitable or usable
spaces located below grade shall be dampproofed from the top of the footing to the finished grade. Masonry wall shall
have not Tess than 3/8 inch Portland cement parging applied to the exterior of the wall. That parging shall be dampproofed
with a bituminous coating, 3 pounds per square yard of acrylic modified cement, 1/8 inch coat of surface- bonding mortar
complying with ASTM C 887 or any material permitted for waterproofing. Waterproofing shall be applied to the exterior of
the wall.
IRC R406.1
(For additional code Information see Section R 406 of the 2003 IRC)
SAFETY GLAZING
17
i s
Hazardous locations. The following shall be considered specific hazard locations for the purposes of glazing:
(abbreviated) Glazing in:
[B] R308.4
(DCD H014)
1) swinging doors except jalousies,
2) fixed and sliding panels of sliding door assemblies and panels in sliding and bi -fold closet door assemblies,
3) storm doors,
4) all unframed swinging doors,
5) doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers, any part of a building wall
enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches measured vertically
above any standing or walking surface.
6) an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24 -inch arc of the
door in a closed position and whose bottom edge is Tess than 60 inches above the floor or walking surface.
.._
7) in an individual fixed or operable panel, other than those locations described in Items 5 and 6 above, that meets all of
the following conditions: 7:1 exposed area of an individual pane greater that 9 square feet, 7:2 bottom edges Tess than 18
inches above the floor, 7:3 top edge greater than 36 inches above the floor, 7:4 one or more walking surfaces within 36
inches horizontally of the glazing.
8) all glazing in railings regardless of an area or height above a walking surface. Included are structural baluster panels
and nonstructural in -fill panels.
9) wall and fences enclosing indoor and outdoor swimming pools, hot tubs and spas where the bottom edge of the glazing
is less than 60 inches above a walking surface and within 60 inches horizontally of the water's edge. This shall apply to
le glazing In all panels in multiple glazing.
`
Printed 02/23/2007
Page 4 of 5
Form # DCD A100
17
10) adjacent to stairways, landings and ramps within 36 inches horizontally of a walking surface when the exposed surface
of the glass Is Tess than 60 inches above the plane of the adjacent walking surface.
11) adjacent to stairways within 60 inches horizontally of the bottom tread of a stairway in any direction when the exposed
surface of the glass is less than 60 inches above the nose of the tread.
.
Skylight and sloped glazing. Glass or other transparent of translucent glazing material installed at a slope of more than
15 degrees from vertical.
R 308.6.1
-
Permitted materials. 1) laminated glass with a minimum 0.015 -inch polyvinyl butyral interlayer for glass panels 16 square
feet or less in area located such that the highest point of the glass is not more than 12 feet above a walking surface or
other accessible area; for higher or larger sizes , the minimum interlayer thickness shall be 0.030 inch. 2) Fully tempered
glass. 3) Heat - strengthened glass. 4) Wired glass. 5) Approved rigid plastics.
R 308.6.2
.
For further glazing code requirements, check with the local building inspector.
GARAGES AND CARPORTS
18
Opening protection. Openings from private garage directly into a room used for sleeping purposes shall not be permitted.
Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 -3/8 inches in
thickness, solid or honeycomb core steel doors not less that 1 -3/8 inches thick, or 20- minute fire -rated doors.
R309.1
Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage
shall be constructed with a minimum No. 26 gage sheet steel or other approved material and shall have no openings into
the garage.
R309.1.1
Separation required. The garage shall be separated from the residence and its attic area by not less than 1/2 inch
gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms
above by not less than 5/8 inches Type X gypsum board or equivalent. Where the separation is a floor - ceiling assembly,
the structure supporting the separation shall also be protected by not less than 1/2 inches gypsum board or equivalent.
R309.2
Floor surface. Garage floor surfaces shall be of approved noncombustible material. The area of floor used for parking of
automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
entry doorway.
R309.3
Carports. Carports shall be open on at least two sides. Carport floor surfaces shall be of approved noncombustible
material. Carports not open on at least two sides shall be considered a garage and shall comply with the provisions of this
sections for garages. Exception: Asphalt surfaces shall be permitted at ground level in carports and sloped to facilitate the
movement of liquids to a drain or toward the main vehicle entry doorway.
R309.4
LIGHT, VENTILATION AND HEATING (Section R303)
1 9
Habitable rooms. All habitable rooms shall be provided with aggregate glazing area of not less than 8 percent of the floor
area of such rooms. Natural ventilation shall be through windows, doors, louvers or other approved openings to the
outdoor air. Openings shall be provided with ready access or shall other wise be readily controllable by the building
occupants and minimum open able areas to the outdoors shall be 4 percent of the floor area being ventilated.
R303.1
Exception: 1) Glazed areas need not be open able with approved mechanical ventilation's system...providing 15 cubic
feet per minute air exchange. 2) Glazed areas need not be provided in rooms where Exception 1 above is satisfied and
artificial Tight provides an average 6 foot candle over area of the room at height of 30 inches above the floor level.
Mechanical Ventilation. Kitchens- ventilation rate 100 cfm intermittent or 25 cfm continuous.
Source Specific Ventilation: Source specific exhaust ventilation Is required in each kitchen, bathroom, water closet,
laundry room, indoor swimming pool, spa, and other rooms where excess water vapor or cooking odor is produced.
IRC M 1506.3
WSVIAC 302.2.1
USEFUL INFORMATION
20
Whirlpool baths shall have a removable panel for sufficient size to access the pump.
UPC 415.1
Pipe Sleeves shall be provided to protect all piping through concrete and masonry walls.
UPC 313.10.1
The grade away from foundation walls shall fall a minimum of 6 " within the firsts 10 feet.
IRC R401.3
Fuel burning appliances require outside combustion air if placed in garage that are classified as unusually tight.
IMC Section 702
Premises identification. Approved numbers or address shall be provided for all new buildings in such a position as to be
plainly visible and legible from the street or road fronting the property.
IRC R321.1
21
Crawl space clearance Minimum height shall be 18 inches clearance to the bottom of wood floor joist or a minimum of12
inches to wood girders (breams).
IRC R 319.1 S1.
Y
Moisture barrier. Polyethylene sheeting of minimum 6 -mil thickness shall be placed over the granular base. Joints shall
be lapped 6 inches and left unsealed. The polyethylene membrane shall be placed over the pressure preservatively
treated - wood sleepers and shall not extend beneath the footing plates of the exterior walls.
IRC R504.2.2
l/
Removal of debris. The under -floor space shall be cleaned of all vegetation and organic material. All wood forms used for
placing concrete shall be removed before a building is occupied or used for any purpose. All construction materials shall
be removed before a building is occupied or used for any purpose.
IRC R408.4
♦�
�'"
22
Insulation for Attics and Vaulted Ceilings. At least 1.5 Inches between the tip of the bats and the underside of the roof
sheathing is left open for ventilation in each cavity to allow a ventilation rate of 3.0 air changes per hour. Provide insulation
baffles or taper insulation to allow for the required air changes.
For vaulted ceilings, provide ridge vent or vent to a gable end to allow continous air flow.
2004 WSEC
Section 1007
2 ` ;
SITE ADDRESS: Premises Identification. Approved numbers or addresses shall be provided for all newbuildings in such
a position as to be plainly visible and legible from the street or road fronting the property.
SECTION R321
R321.1
Printed 02/23/2007
Page 5 of 5
Form # DCD A100
MESONS
No changes shalt be made to the scope
c; c.-rz:lt without prior approval cf
e ila Building 13Msazrn.
NOTE: Rcvi.lions will require a new plan submittal
and may include additional plan review fees.
SO (14- C c u•rct,N1
Perrnft
Plan review approvals` ' to_wocs and
Approval of construction documents does' riot
the violation of any accepted code or ordinance. Receipt
of approved Field Copy and condRlans is ac
4.,
BY
Date: d / /0 7 .
City of Tukwila
BUILDING DIVISION
100
Z G�a`r p ak� �apv�-
RECEIVED
crry OF TUKWILA
FEB 15 20071
PERMIT CENTER
FEB 2 6 2007
Ci Of Tukwila
BUILDING DIVISION
CORRECTION
LT R#
704--03c0
39-
WILL vL Roo Levc l
Soatc
REVI1 WED FOR
CODE IOMPLIANCE
2 6 2007
71 City Of Tukwila
BUILDING DI1 /ITON
cm40FTurcwrt A
/Z
1,800 S? Ff • FEB 1 2007
PERM € fm -rE
_ 0
s
rr-
r.
Pvuvt el.a +t ov %oat
E x.k.5-\-k‘&5 13 a5ctv‘en 4
11 - 3"
•00 F+ Sq uu,A.' SQ ctcc
13c1 s c w►ah 4-
REVIEWED FOR
CODE COMPLIANCE
FEB 2 6 2007
City Of Tukwila
' BUILDING DIVISION
RECEIVED
CITY Off TUKW1L
FEB 15 2007
P ER M7
1
a n
`
C ouJL S ea ��
0
,63 F.4 LW\v‘,5 S Pc:cc
c
uJ
REVIEWED FOR
CODE COMPLIANCE
FEB 2 6 2007
City Of Tukwila
BUILDING Di /TSTON
CITY OF TUKWILA
FEB 15 2007
PERM[-
07 -31 -2007
DARWIN GARCIA
5343 140 S
TUKWILA WA 98168
RE: Permit No. D07 -036
15460 65 AV S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in wr#ine and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 09/25/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Ter Marshall,
Permit Technician
xc: Permit File No. D07 -036
CltJ/ of Tukwila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
February 9, 2007
Darwin Garcia
5343 S 140 St
Tukwila WA 98168
RE: CORRECTION LETTER #1
Development Permit Application Number D07 -036
Deng Residence —15460 65 Av S
Dear Mr. Garcia,
This letter is to inform you of corrections that must be addressed before your development permit(s) can
be approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Planning Department. At this time the
Building, Fire, and Public Works Departments have no comments.
Planning Department: Brandon Miles, at 206 431 -3684, if you have questions regarding the
attached memo.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and/or other documentation. The City requires that four (4) complete sets of revised
plans, specifications and/or other documentation be resubmitted with the appropriate revision
block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 433 -7165.
encl
File No. D07 -036
City of Tukwila
Steven M Mullet, Mayor
Department of Community Development Steve Lancaster, Director
P:Uennifer\Correction Letters \2007007-036 Correction Ltr #1.DOC
jem
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
DATE:
CONTACT:
RE:
ADDRESS:
ZONING:
February 8, 2007
Darwin Garcia
D07 -036
15460 65 Ave S
LDR
PLANNING DIVISION COMMENTS
The Planning Division of DCD has reviewed the above permit application. The application as
submitted cannot be approved.
Provide clarification on the proposed use of the structure. The house appears to be a duplex or
an accessory dwelling unit (ADU). The property is eligible to have an ADU, provided that the
ADU is not greater than 33 percent of the floor area of the primary structure. Additionally, there
must be at least three parking stalls on the property. The plans provided do not provide enough
detail in order to determine if you meet the requirements to have an ADU.
Provide the following:
1. Complete the section of the building permit application which requests information on
ADU units (highlighted application provided).
2. Complete scaled plans which show the layout of the primary dwelling unit and the
accessory dwelling unit.
3. A site map which shows the location of parking space on the property.
DEPARTMENTS:
PV, p2.
ding Division
Public Works
Complete
Comments:
Documents/routing slip.doc
2 -2&02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D07 -03tp DATE: 02 -15 -07
PROJECT NAME: DENG RESIDENCE
SITE ADDRESS: 15460 65 AV S
Original Plan Submittal
X Response to Correction Letter # 1
Response to Incomplete Letter #
Revision # After Permit Issued
❑
•
DETERMINATIQN OF COMPLETENESS: (Tues., Thurs.)
APPROVALS OR CORRECTIONS:
Fire Prevention
Structural
Incomplete
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
DATE:
DATE:
111 02.
Planning Division
Permit Coordinator n
DUE DATE: 02-20-07
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
DUE DATE: 03-20 -07
Approved ❑ Approved with Conditions Q Not Approved (attach comments) E
Notation:
REVIEWER'S INITIALS:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
DEPARTMENTS:
W 2 .1•
Buil Wing Division
Complete
Comments:
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D07 -036 DATE: 02 -05 -07
PROJECT NAME: DENG RESIDENCE
SITE ADDRESS: 15460 65 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
51r i-&- Fire Prevention
orks g Structural
1 LM4 hIL * 14-07
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete ❑
44 2.S"(n
Pt Division 51
Permit Coordinator
DUE DATE: 02-06-07
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
APPROVALS OR CORRECTIONS:
DI
No further Review Required
DATE:
Approved ❑ Approved with Conditions n Not Ap proved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 03-06-07
Permit Center Use Only
CORRECTION LETTER MAILED: 04114
Departments issued corrections: Bldg ❑ Fire ❑ PIng' PW ❑ Staff Initials:(
IA Entered in Permits Plus on
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
Revision submittals must be submitted In person at the Permit Center. Revisions will not be accepted through
the mail, fad etc.
Date: 2- 15 — et - Plan Check/Permit Number: Do I,- — 0 3 to
❑ Response to Incomplete Letter #
Er Response to Correction Letter # 41
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Devt� 2eS tcICI CC
Project Address: / C 4 (c (75 Ave' S
Contact Person: cc) rlrw th, Gairtat Phone Number: CZo J 383-5&3/
5&03/
Summary of Revision:
13054 - - -0.-e of - g.t
17t ~Hove 2 tvv4 ec to r (IA t s .
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by: 1
%applications\fomms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Steven M Mullet, Mayor
Steve Lancaster, Director
RECSYED
CITY OP TURIN/Lit
FEB 15 2007
PFAuurCENrEfi
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Permit Center /Building Division:
206 - 431 -3670
Public Works Department:
206 - 433 -0179
Planning Division:
206 - 431 -3670
STATE OF WASHINGTON)
COUNTY OF KING
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
ss.
[p print]
1. I have made application for a building permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the State of
Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of
Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW
18.27.090.
3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of
Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions
stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that
after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized
under this building permit to be exempt under No. 1 , and will therefore not be performed by a registered
contractor.
1 understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an
unregistered contractor to perform construction work.
% .%\m %M
A. II l
`s�` i
S sG� 4)i- 11,% 00 %N, �i a vl ‘ V r'ZS
/III WA S T % ,s`
\applications\8 -2004 affidavit in lieu of contractor registration
day of
, states as follows:
APPLICANT
Signed and swom to before me this
PERMIT NO.: �r
TI. RY PUBLIC in and for the State of Washington,
Residing at / :%)l,Urk //i4
Name Name as commissioned:
, 20 crl.
, County.
My commission expires: 0 S -aW -/ v
18.27.090 Exemptions. This chapter shall not apply to:
1.
2. An authorized representative of the United States
Government, the State of Washington, or any
incorporated city, town, county, township,
irrigation district, reclamation district or other
municipal or political corporation or subdivision of
this state;
3. Officers of the court when they are acting within
the scope of their office;
4. Public utilities operating under the regulations of
the utilities and transportation commission in
construction, maintenance, or development work
incidental to their own business;
5. Any construction, repair or operation incidental to
the discovering or producing of petroleum or gas,
or the drilling, testing, abandoning, or other
operation of any petroleum or gas well or any
surface or underground mine or mineral deposit
when performed by an owner or lessee;
6. The sale or installation of any finished products,
materials, or articles of merchandise which are not
actually fabricated into and do not become a
permanent fixed part of the structure;
7. Any construction, alteration, improvement or
repair of personal property, except this chapter
shall apply to all mobile, manufactured housing. A
mobile /manufactured home may be installed, set
up, or repaired by the registered or legal owner,
by a contractor licensed under this chapter, or by
a mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW;
8. Any construction, alteration, improvement, or
repair carried on within the limits and boundaries
of any site or reservation under the legal
jurisdiction of the federal government;
9. Any person who only furnished materials,
supplies, or equipment without fabricating them
into, or consuming them in the performance of, the
work of the contractor;
10. Any work or operation on one undertaking or
project by one or more contractors, the aggregate
contract price of which for labor and materials and
all other items is less than $500.00, such work, or
operations being considered as of a casual, minor,
or inconsequential nature. The exemption
prescribed in this subsection does not apply in all
instance wherein the work or construction is only a
part of a larger or major operation, whether
undertaken by the same or a different contractor,
or in which a division of the operation is made into
\applications\8 -2004 affidavit in lieu of contractor registration
contracts of amounts Tess than $500.00 for the
purpose of the evasion of this chapter or
otherwise. The exemption prescribed in this
subsection does not apply to a person who
advertises or puts out any sign or card or other
device which might indicate to the public that he is
a contractor, or that he is qualified to engage in
the business of contractor;
11. Any construction or operation incidental to the
construction and repair of irrigation and drainage
ditches of regularly constituted irrigation districts
or reclamation districts; or to farming, dairying,
agriculture, viticulture, horticulture, or stock or
poultry raising; or to clearing or other work upon
land in rural districts for fire prevention purposes;
except then any of the above work is performed
by a registered contractor;
12. An owner who contracts for a project with a
registered owner;
13. Any person working on his own property, whether
occupied by him or not, and any person working
on his residence, whether owned by him or not but
his exemption shall not apply to any person
otherwise covered by this chapter who constructs
an improvement on his own property with the
intention and for the of selling the
improved property;
14. Owners of commercial properties who use their
own employees to do maintenance, repair, and
alteration work in or upon their own properties;
15. A licensed architect or civil or professional
engineer acting solely in his professional capacity,
an electrician licensed under the laws of the state
of Washington, or a plumber licensed under the
laws of the state of Washington while operating
within the boundaries of such political subdivision.
The exemption provided in this subsection is
applicable only when the licensee is operating
within the scope of his license;
16. Any person who engages in the activities herein
regulated as'' an employee . of a registered
contractor with wages as his sole compensation;
17. Contractors on highway projects who have been
prequalified.as required by chapter 13 of the Laws
of 1961, RCW 47.28.070 with the department of
transportation to perform highway construction,
reconstruction, or maintenance work.