Loading...
HomeMy WebLinkAboutPermit D07-046 - AIRGAS INC - DOOR AND WALLAIRGAS INC 1097 ANDOVER PK E D07 -046 Parcel No.: 2623049106 Address: 1097 ANDOVER PK E TUKW Suite No: Tenant: Name: AIRGAS INC. Address: 1097 ANDOVER PK E , TUKWII,A WA City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: SECURITY CAPITAL INDUSTRIAL Address: C/O DELOITTE & TOUCHE LLP , 2235 FARADAY AVE STE 0 92008 Phone: Contact Person: Name: SEAN NEWTON Address: 1932 FIRST AV STE 408 , SEATTLE WA 98101 Phone: 206 720 -7001 DEVELOPMENT PERMIT Contractor: Name: SIERRA CONSTRUCTION CO INC. Address: 19900 144TH AVENUE NE , WOODINVILLE WA 98072 Phone: (425)487 -5200 Contractor License No: SIERRCC 145N8 Value of Construction: Type of Fire Protection: Type of Construction: $15,000.00 * *continued on next page ** Permit Number: D07 -046 Issue Date: 03/01/2007 Permit Expires On: 08/28/2007 Expiration Date: 03/31/2008 Steven M Mullet, Mayor Steve Lancaster, Director DESCRIPTION OF WORK: DEMOLISH INTERIOR OFFICE PARTITIONS, DOORS & FRAMES, INFILL DOOR OPENING WITH NEW WALL, RELOCATE DOOR & FRAME, UPDATE DOOR HARDWARE. Fees Collected: $518.28 International Building Code Edition: 2003 Occupancy per IBC: doc: IBC -10/06 D07 -046 Printed: 03 -01 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signatur I hereby certify that I have read an governing this work will be complie The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pert nuance of work. , I am authorized to sign and obtain this development permit. Date: 3 Signature: Print Name: doc: IBC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us N cTG1/i c CGIG.-) Permit Number: D07 -046 Issue Date: 03/01/2007 Permit Expires On: 08/28/2007 Date: v ✓1 "` i•)r- -/ -07 Steven M. Mullet, Mayor Steve Lancaster, Director this permit and know the same to be true and correct. All provisions of law and ordinances ther specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -046 Printed: 03 -01 -2007 Parcel No.: 2623049106 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1097 ANDOVER PK E TUKW AIRGAS INC. PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -046 ISSUED 02/08/2007 03/01/2007 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or D07 -046 Printed: 03 -01 -2007 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 26: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 27: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 28: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 29: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of D07 -046 Printed: 03 -01 -2007 such condition or violation. doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 30: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** 007 -046 Printed: 03 -01 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 LL. C hi -, Date: 3'1' 7 D07 -046 Printed: 03 -01 -2007 CITY OF TUKWILA...) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htV://wwwci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 10)177 trainer Tenant Name: t"t C Gas - I-v\Cs, Property Owners Name: "Sale. CA A\ Mailing Address: — 1-752-A5 (o `i\ G sie- 5, CONTACT PERSON - who do we contact when your permit is ready to be issued Name: SQOi( ? mot(\ Mailing Address: V\32_ V \l' ik- isV2, S take. t iOIS E -Mail Address: SQof J G64 0. \Ake a5, Cfi W1 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: CJ \Q.f r0.. GOA51/4- ck-kovN Mailing Address: \ 0 1 1 i'e■ ag \� Contact Person: oxv o CI� Cook E -Mail Address: eofi C. S k c caAA, COY\ Contractor Registration Number: S CC % Company Name: C roc* /VtCAMeC Mailing Address: VV - 32- . r-ACSk $ € 5tAie 11 0 Contact Person: c J CAA* E -Mail Address: C.fA IA Q C,'( adroAlireC'kS ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: %1P Contact Person: E -Mail Address: Q:tApplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Perm No. 1) - 1 r Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: toZaff9 t o6 Suite Number: Floor: New Tenant: ® Yes ❑..No Kiak City W State Day Telephone: In(s) 7 / " 700 t Zip City State Zip Fax Number: �( -"ZAMA \P QodyA2 c1 O7Z- City State Zip Day Telephone: 425 —9/7 — S2003 Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record t'k W kC 931,0k City State Zip Day Telephone: IOC, —7W — 7001 Fax Number: 2-00 - 77 - Z (Q City Day Telephone: Fax Number: Page 1 of 6 State Zip I" BUILDING PERMIT INFORM,,ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1S,OQD Existing Building Valuation: $ Scope of Work (please provide detailed information): De.racAnh 04-ice r i t# k- v s c-CO,.tn.RS , \i & &10 t o QeAl\ \04 ( r \QC (AP_ &Uf &co wvz. um €_, clo ho c&\ o..ie_. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 71 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safe Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line0-2006 - Permit Application.doc Revised: 9 -2006 bh 0.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of , Construction per , IBC- Type of . ';,Occupancy per IBC l' Floor k(2-$Z 'k 7.-3$ t9 \ItQJ 5QtAliigek 2`5 —1 2nd Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck I" BUILDING PERMIT INFORM,,ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1S,OQD Existing Building Valuation: $ Scope of Work (please provide detailed information): De.racAnh 04-ice r i t# k- v s c-CO,.tn.RS , \i & &10 t o QeAl\ \04 ( r \QC (AP_ &Uf &co wvz. um €_, clo ho c&\ o..ie_. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 71 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safe Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line0-2006 - Permit Application.doc Revised: 9 -2006 bh 0.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: _ ee /114 Print Name: n CNA) A Mailing Address: \ . ■ C54 - SVIZW- t ai Date Application Expires: Date Application Accepted: Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: _ City Date: 2,19 /07 21a6 -- 720 - 7001 \N Pc- State Zip Staff Initials: Page 6 of 6 Parcel No.: 2623049106 Address: 1097 ANDOVER PK E TUKW Suite No: Applicant: AIRGAS INC. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: THE JULIE ANN CHAN FAMILY TRUST RECEIPT Receipt No.: R07 -00305 Payment Amount: $315.88 Initials: JEM Payment Date: 03/01/2007 02:41 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 2432 315.88 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 311.38 000/386.904 4.50 Total: $315.88 Permit Number: D07 -046 Status: APPROVED Applied Date: 02/08/2007 Issue Date: - z ; doc: Receipt-06 Printed: 03 -01 -2007 Parcel No.: 2623049106 Permit Number: D07 -046 Address: 1097 ANDOVER PK E TUKW Status: PENDING Suite No: Applied Date: 02/08/2007 Applicant: AIRGAS INC. Issue Date: Receipt No.: R07 -00187 Payment Amount: $202.40 Initials: JEM Payment Date: 02/08/2007 10:24 AM User ID: 1165 Balance: $315.88 Payee: CRAFT ARCHITECTS, PLLC TRANSACTION LIST: Type Method Description Amount Payment Check 2869 202.40 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 202.40 Total: $202.40 1 -:677 U/08 T716 TOTAL 2020 riod Rar int -OS PrintArl: f19 -(1R -90(17 Proje t: /1i ✓ ‘4 5 5 Type of Ins ection: /A./a / Address: /!)`i 7 /N/ -, /)/lf Date Called: Special Instructions: Date Wanted: J 6 -0 7 /a.r j Requester: Phone No: _ 02l>l - 5 - d%2 INSPECTI . N NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER (206)431 -3 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ()/( /,, 4)itt $58.0b INSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Pro• // C -S — —fli / Type of Inspect' 12 L'a ' ii°i /l yv/j Address: Date Called: S pecial ' instructions: Date Wanted: .C:— 3 -v 7 / a.m p.m. Requester: Phone No: 2j57-)2 , INSPECTI' NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 + .r Approved per applicable codes. Corrections required prior to approval. OMNIENTS: 8.00 REINSPECTIO FEE REQUIRED rior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Da Date: INSPECTION RECORD Retain a copy with permit f �,. lhAar Project: � lf Type o nspe tio ! � C�J ) r Address: G 1 / 7 J —id/`— Date a = • Spec al Inst uctio s: Date Wanted: 31 Requester: Phone No: L CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 'J ( 06 43 - 67 OMMENTS: Approved per applicable codes. Corrections required prior to approval. El $58.0d(tEINSPECTION FEE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: INSPECTION RECORD ?etain a copy with permit PERM Proj c t: fi /C (0 Type of Inspection: . ra 1-9 vi , v`/ 4 Address: 16 7 7 J'1 /Q ax f Date Called: Special Instructions: Date Wanted: m. 3- S- o7 p Requester: Phone No: �cG -57q DS? C INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: / r711-rvii✓v-6 -- i Am) )vcn/, -- At) /� ✓ov) ./ !' nspec A JP.I. 1 L 00 REINSPECTION FEE IQUIRED. rior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 00. Call to sechedule reinspection. Receipt No.: Date: Date: Approved per applicable codes. El Corrections required prior to approval. Project: Pi 1 Q&A -s Type of Inspection: /7f2e 1 ki Address: J 7/ 7 Suite #: A-- P Contact Person: / Monitor: Special Instructions: Pre -Fire: ,U Phone No.: a6- 57 `) - ocfa Needs Shift Inspection: }' Sprinklers: Fire Alarm: y t Hood & Duct: Monitor: Pre -Fire: ,U Permits: i iip Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 I I Approved per applicable codes. COMMENTS: S, cu l �bd2pLtc.� -Q /. L INSPECTION RECORD Retain a copy 4mith permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS Corrections required prior to approval. Inspector: 5/ Date: ' Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: Sprinklers: Type of Inspection: �,(2.< li,,JA Address: /U q -) Suite #: A P ''' Contact Person: MAP_ k ( a_, I F 7 Special Instructions: Occupancy Type: Phone No.: 3o4- 71'- 0 q�3 7 tI (,;- - 7/12 6,1 / 'F eo, II h '- -e 1-,1,, t_ el-- c o / 1/1 "-i,e / S / ,✓ C./ i'-1 gC n/€ 5-R, Project: 1 - r> �; Sprinklers: Type of Inspection: �,(2.< li,,JA Address: /U q -) Suite #: A P ''' Contact Person: MAP_ k ( a_, I F 7 Special Instructions: Occupancy Type: Phone No.: 3o4- 71'- 0 q�3 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT � Y"'7- 0''.t- PERMIT NUMBERS Corrections required prior to approval. Inspector: Y;, S / Date: x //310 - 7 Hrs.: I /J /) n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address 1 0 79 Andover Park East D 2/8/2007 Air Gas Inc. For Building Department Use rime c opir Tukwila, WA 98188 Applicant Name: Sean Newton, Craft Architects Applicant Address: 1932 First Ave, Suite 408, Seattle, WA 98101 Applicant Phone: (206) 720 -7001 , Project Description ❑ New Building ❑ Addition ❑ Alteration _ Refer to WSEC Section 1513 for controls and commissioning 0.2 W /ft .• Plans Included requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly On` plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft ** Area in ft Allowed x Area N/A Covered Parking (standard paint) REVI E 1 OR CODE COMPLIANCE 0.2 W /ft Covered Parking (reflective paint) A rwe+R oloc f 0.3 W /ft ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts A Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 11 A Covered Parking (standard paint) REVI E 1 OR CODE COMPLIANCE 0.2 W /ft Covered Parking (reflective paint) A rwe+R oloc f 0.3 W /ft A Open Parking r 2 7001 FEB f 0.2 Wlft a TM j(� Outdoor Areas 0.2 W /ft Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts O Location Fixture Description Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x If) ' qa Covered Parking (standard paint) REVI E 1 OR CODE COMPLIANCE 0.2 W /ft Covered Parking (reflective paint) A rwe+R oloc f 0.3 W /ft A Open Parking r 2 7001 FEB f 0.2 Wlft a TM j(� Outdoor Areas 0.2 W /ft O Bldg. (by facade) I n / IR 0.25 W /ft2 D 20071 Bldg. (by perim)' �� 7.5 Wllf PERMI1. Q P Choose either the facade are or th A °-fie t) Total Allowed Watts Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 2004 Washington State Nonresidential Energy Code Compliance Forms 2004 Washington State Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM Revised May 2005 Maximum Allowed Lighting Wattage (Interior) Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. Proposed Lighting Wattage (Interior) 3. List all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior) r fisted maximum input wattage. or fixtures with hard -wired oanasrs only, Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. (tf Space Heat Type 0 Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing T X 1 00 = Concrete/Masonry Option p 0 yes Check here if using this option and if project meets all requirements for the Concrete/Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying Ono assembly below. Envelope Requirements (enter values as applicable) Fully heated/cooled space Minimum Insulation R- values Roofs Over Attic All Other Roofs Air Gas Inc. Opaque Walls' ti f A Below Grade Walls I Floors Over Unconditioned Space Slabs -on -Grade Seam Newton Radiant Floors Applicant Address: 1932 First Ave, Suite Maximum U- factors Opaque Doors WA 98101 111 tt ' Vertical Glazing N Overhead Glazing N Pt Maximum SHGC (or SC) Vertical /Overhead Glazing I Project Info Project Address 1097 Andover Park East Date 2/8/2007 Air Gas Inc. For Building Department Use Tukwila, WA 98188 Applicant Name: Seam Newton Applicant Address: 1932 First Ave, Suite 408, Seattle, WA 98101 Applicant Phone: (206) 720 -7001 2004 Washington State Nonresidential Energy Code Compliance Forms 2004 Washington State Nonresidential Energy Code Compliance Form Envelope Summary Climate Zone 1 ENV -SUM Revised May 2005 Project Description I ❑ New Building ❑ Addition El Alteration ❑ Change of Use Compliance Option ❑ Prescriptive ❑ Component Performance ❑ Systems Analysis (See Decision Flowchart (over) for qualifications) Semi- heated space 2 Minimum Insulation R- values Roofs Over Semi - Heated Spaces I V/P 1. Assemblies with metal framing must comply with overall U- factors 2. Refer to Section 1310 for qualifications and requirements Notes: Opaque Concrete /Masonry Wall Requirements Wall Maximum U- factor is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete /Masonry Option, list walls with HC >_ 9.0 Btu /ft F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10 -9 in the Code. Wall Description (including insulation R -value & position) U- factor Joanna Spencer Re: Gas Inc TI @ 10 Andover Pk E From: Han Kirkland To: Spencer, Joanna; Still, Bryan Date: 02/12/2007 10:58 am Subject: Re: Air Gas Inc. TI @ 1097 Andover Pk E Joanna, Per Bryan, everything for this address is current. Good to go! -Han »> Joanna Spencer 02/09/07 4:36 PM »> Are they current on their backflows ? Thanks, joanna PERMAN FILE COPY Pa • e ACTIVITY NUMBER: D07 -046 DATE: 02 -08 -07 PROJECT NAME: AIRGAS INC. SITE ADDRESS: 1097 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: A'r o (/ Bui s' ng Division AY o 2 I Public Works PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP qi A Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required Documents/routing slip.doc 2 -28 -02 Incomplete ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02-13-07 Not Applicable ❑ No further Review Required DATE: 2• ' IP anning Division AJ Permit Coordinator n n DUE DATE: 03-13-07 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License SIERRCC145N8 Licensee Name SIERRA CONSTRUCTION CO INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600634891 Ind. Ins. Account Id #7 Business Type CORPORATION Address 1 19900 144 TH AVE NE Address 2 City WOODINVILLE County KING State WA Zip 98072 Phone 4254875200 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/28/1986 Expiration Date 3/31/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date COLLINS, ROGER D Cancel Date 01/01/1980 Bond Amount COLLINS, KIMBERLY J #7 01/01/1980 5767391 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #7 SAFECO INS CO OF AMERICA 5767391 08/26/2001 Until Cancelled $12,000.00 07/30/2001 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= SIERRCC145N8 03/01/2007 i ABBREVIATIONS AB AG A/C AGP ACT ADH ADJ ANT AF AFF AL ALT AP ACCESS PANEL APPROX APPROXIMATE ARCH ARCHITECTURAL ASPH ASPHALT BD BOARD BETA BETr EN BLDG BUILDING BLK BLOCK BLDG BUILDING BM BEAM BR6 BEARING DOT BOTTOM BSMT BASEMENT BUR BUILT UP ROOF CAB CABINET CS CATCH BASIN GBU CEMENTITIOUS BACKER UNIT GEM CEMENT GER CERAMIC CFM CUBIC FEET PER MINUTE OFT CONDUCTIVE FLOOR TILE C6 CORNER GUARD CHBD CHALK BOARD CI CAST IRON CJT CONTROL JOINT CLF CHAIN LINK FENCE GLG CEILING GJ CONSTRUCTION JOINT CLK CAULKING GLO CLOSET • CLR CLEAR CM CONCRETE MASONRY UNIT GNTR COUNTER CO CLEANOUT COL COLUMN LONG CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS CORR CORRIDOR CPT CARPET CT CERAMIC TILE GTR CENTER GY CUBIC YARD LAM LAY LB LF DBL DOUBLE L6 DEPT DEPARTMENT LH PET DETAIL DF DRINKING FOUtTAIWW/O COOLER) LT DIA DIAMETER DIAL DIAGONAL DIM DIMENSION DISP DISPENSER ON DOYEN DR DOOR OR DRAiN VAR DRAYER DS PO SPOUT DW DISITYtASHER DAS DRAWING E EAST EA EACH EB EXPANSION BOLT EJ EXPANSION JOINT EL ELEVATION ELEG ELECTRIC ELEV ELEVATOR EM ENTRY MCAT DOR I..• ' Y ENCL E A.09 E OR E OSED EP ELECTRICAL PA\. EM ELECTRIC ',ATM COOLER EPX EPDXY EQ EOJAL. EOPF EQJi°NT EST ESTMATE EX EX°A1ti.5.0% EXIST EXiSTNG EX* EXTt'?r :�0R FA F50 FOC FGTY FD FGN FE FEC FIN ANGLE CENTER LINE DIAMETER OR ROUND NUMBER OR POUND PENNY PERPENDICULAR PLATE ANCHOR BOLT ACOUSTICAL OR AIR CONDITIONING ACOUSTICAL PANEL ACOUSTICAL TILE ADHESIVE ADJACENT ADJUSTABLE ACCESS FLOOR ABOVE FINISH FLOOR ALUMINUM ALTERNATE FRE ALA X HIGH!P BY OTt PlARRN;S P BY COVRACRIR INSIXIED BY CONTRACTOR FACTORY FLOOR DRAIN FO.p\DAT .' F,RE Exrissitee FIRE EXTINGUi5I GA&NET FI .S t a • FL FLOOR FLG FLASHING FLUOR FLUORESCENT FM FACTORY MUTUAL FOG PAGE OF CONCRETE FOF FACE OF FINISH FOIL FURNISH BY OP14ER INSTALL BY CONTRACTOR F010 FURNISH BY OWNER INSTALL BY OWNER FOS FACE OF STUD FS FULL SIZE FT FEET FTG FOOTING FTIC FURNISHED BY TENANT INSTALLED BY CONTRACTOR FTIO FURNISHED BY TENANT INSTALLED BY OWNER FURRING FUTURE FUTURE ROUGH IN ONLY FURR FUT FUTURE - RIO FX GA GALV GB GL GLBM GEN CONTR GND GR GAB HB HG HDR WAD WINE HM HORIZ HR HT HT& HVAC lG IHM iN INCL INSUL INT JAN Jr KIT KO KS MACH MATL MAX MEGH MET OR MTL MEZZ NFR 141 MIN MIR MSC MID MRGY48 MID MULL NIG 1401# NOM NTS OA OG OD OFF Lai O!°frf OPP FERP PFN PLY Pi-Yd , %) l°NT PR FIXED GAGE GALVANIZED GRAB BAR GLASS OR GLAZING 61U -LAM BEAN GENERAL CONTRACTOR GROUND GRADE GYPSUM WALL BOARD HOSE BIB HOLLOW GORE OR HANDICAP HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING HE:ATINGNENTI L IATIOW AIR CONDITIONING HOT WATER HEATER NSIDE DIAMETER/ DIMENSION NSULATED GLAZING NSULATED HOLLOW METAL NCH NCLUDE NStJ1 ATION NTERiOR JANITOR JOINT KiTCHIEN KNOCK OUT KNEE SPACE LAMINATE LAVATORY LAG BOLT LIKE. FOOT LENGTH LEFT HAND LOCKER LIGHT MACHINE MATERIAL MAXIM U4 MECHANICAL METAL MEZZANINE MANUFACTURER MANHOLE MINIMUM MIRROR MISCELLAN OUS Ma-DINS MOISTURE RE GYP T5 MOUNTED TV MD_LION TYP 'JL UON NORTH NOT IN CONTRACT lit NOMINAL NOT TO SCALE OVERA�.L ON CENTER OUTSI DIA 'ETEQI OFFRCE 0/MEAD OPPOSITE F s OPE Y6 OPPOSITE PE'G1i...AR PRERiNi KATE OR . ROPERTY LAE °ate% C LA' KATE PLYdiO08 PANEL PAM' PAR PS PSF PSI PT PTD PTD/R PTN PTR PVMT OT QUARRY TILE R RA RAD RB R45 RD RD/0 REBAR REF REFR REINF RE& REV RH RESIL RM RO RT RUB RV5 RA RNL 5 5C SCD SGHD 5D SECT Sr SHT6 SIM 5K SIR 5ND 5NR 5NT SPEC 50 55T SDK ST STA STC STD STL STOR STRL SUSP 5V SYM T TB TAB TG THC n R TIG TO TOG TOP T05 TOSL TOIL TPD TPH TPTN VAR VGT VERT VEST YEN VAG A� A'O AG 70 "LIP tiSGT AT PAINT SYSTEM POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED PAPER TOWEL DISPENSER PAPER TOM DISPENSER AND RECEPTABLE PARTITION PAPER TOWEL RECEPTACLE PAVEMENT RISER RETURN AiR RADIUS RESILIENT BASE ROD 4 SHELF ROOF DRAIN ROOF DRAiN OVERFLOW REINFORCING BAR REFERENCE REFRIGERATOR REINFORCED REQUIRED REVISION RIGHT HAND OR ROBE HOOK RESILIENT ROOM ROUGH OPENING RESILIENT TILE RUBBER REVERSE RAIN WATER RAIN WATER LEADER SOUTH SOLiD CORE SEAT COVER DISPENSER SCHEDULE 50AP DISPENSER OR SECTION SQUARE FEET SHEATHING SIMILIAR SEALER SANITARY NAPKIN DISPENSER SANITARY NAPKIN RECEPTACLE SEALANT SPECIFICATION SQUARE STAINLESS STEEL SERVICE SINK STONE/STONE TILE STATION SOL*V TRANSMISSION CLASS STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SHEET VINYL SYMMETRICAL TREAD TOWEL BAR TOP 4 BOTTOM TEMPERED GLASS THICK TIVESHOLD TEMPERED INSULATED GLAZING TO° OF TOP OF CONCRETE TOP OF PAVEMENT TOP OF STEEL TOP OF SLAB TOP OF WALL TOILET PAPER DISPENSER TOILET PAPER HOLDER TOILET PARTITION TUBULAR STEEL TELEVISION TYPICAL I*IDERYIRITE S LABORATORY LWlNNSH'ED ti ES6 OTifl2A15E NOTED URi AL VARIES VINYL COMPOSITION TILE V RT :GAL VESTIBIL_E VINYL VINYL WALL COVOA ' Y sT 111Tci K TAOUT WATER !JOOSET WOOD ,' PE FLANGE lRt GLASS WATER PROOF MATE MeiSTANT MNSSCOT WE'a■s' XT-VR 7RAW ORvER Y7 Y ARD H SYMBOLS COLUMN LINE/GRID LINE DOOR NUMBER TO COORESPOND TO ROOM ENTERING KEY NOTE PARTITION TYPE REVISION ��/yq��p���p�� REVISION J CLOUD AROUND I�LYf�VI� MATCH LINE SHADED PORTION IS THE SIDE CONSIDERED WORK POINT, CONTROL POINT OR DATUM POINT EQUIPMENT NUMBER BUILDING SECTION (IDENTIFY ON PLAN) SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN SECTION IDENTIFICATION SHEET *ERE SECTION 15 DRAM WALL SECTION (IDENTIFY ON ELEVATIONS) DETAIL DETAIL IDENTIFICATION SHEET 1 DETAIL 15 DRAWN DEFERRED SUBM1UALS !WAWA (WA &ORM FRE 51101Q.ER OFFICE 102 0 68.5 • 78 -71 • 9 ,_ O p i' -o° INTERIOR ELEVATION(5) ELEVATION IDENTIFICATION SHEET YIHERE ELEVATION IS DRAWN ROOM IDENTIFICATION ROOM NAME ROOM NO. ROOM FINISH GRADE EXISTING GRADE PROPERTY LINE NEW OR FINISHED CONTOURS EXISTING CONTOURS TOP OF WALL TOP OF CURB TOP OF PAVEMENT PROJECT NORTH DENOTES CHANGE IN ELEVATION GENERAL NOTES I. TIE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, LNG VIN6 11E SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL IECESSARY INDEPDVABZf 8I&IIEERi16 REV1BIS OF THESE CONDITIONS, NO FOR COI4'LIANCE NTH OSHA. SAFETY STANDARDS ARCHITECTS MID THEIR CO II - TANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF TIE CONTRACTORS SAFETY MEASURES. 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES NTH AU. SPECIFIED PRODUCTS RELATING TO THEIR YORK. TIEY ARE TO SUBMIT YRITTO+H O11ECTIDN5 PRIOR TO BIDDING, IF TIE CONTRACTOR HAS AN OaECTION TO ANY PRODUCT AND /OR DISCREPANCIES SEVEN DRAYIN65 AND SPECIFICATIONS a TIE 6BERAL CONTRACTOR SHALL COORDINATE TWEEIR YORK WITH THAT OF OTHER SEPARATE CONTRACTS SUCH AS 516115, 4 DOTER FURNISHED 113 45, Y CH ARE BEING DOLE BY ORIWRS. 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXiSTM6 CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMEDIATE.Y OF ANY DISCREPANCIES BETYEBI ACTUAL. FIELD GOI101T10N AHD CONSTRUCTION DOCI V E5 AN0 HOLD ALL YIORK IN 'THAT AREA UNIT & SUCH DISCREPANCIES ME RESOLVED. 5. 1W 6EERAL CONDITIONS OF TIE CONTRACT FOR CONSTRUCTION, MA DOCUMENT A201, TIE LATEST EDITION, SHALL. BE INSPECTED AT THE A .0 TEGTS OFFICE. b. SEPARATE PERMITS, YEN AID /OR Y U YIORK ITEMS ARE DE516WBALD IN NAiURE, SHALL BE OBTAiIED BY THE CONTRACTOR FOR MrECHANiCAL, FMB*, FIRE 5PRINrLER5 ECTRICAL AND FIRE ALARM DESCRIPTIVE, DETAILED DESIGN NO REQUIRED SUBMITTAL POOkENTS INFORMATION SHALL BE PROVIDES FOR REVIOM BY THE RE6ULA1114G MINORITIES MD BY THE O'A /i8VANT /ARCNIhCT FOR APPROVAL PRIOR TO ANY PiORK 13ElN6 PERFORM SEE SPECIFICATIONS FOR REGMIRBENT FOR VESIGWEUILD FIRE 5PR I* ER SYSTEM. 91314T PLAN TO AND OBTAIN PERMIT FROM THE FIRE PREVENTION BUREAU FOR FIRE SPRINKLER SYSTEM INSTALLATION OR MODiFICATION. T. COMET! FIRE SPRNCLER DRAWII% HILL BE SUBI'IT IW BY THE FIRE PROTECTION CONTRACTOR b. THE INSTALLATION OF AUTOMATIC FRE M EER SYSTf4S SHiALL GOt'ftY YITHH THE INTERNATIONAL B MUM CODE 4. SFEGIAL INSPECTIONS HERE REWIRED BY THE EUILP% OFFICIAL SHALL BE PERFORM BY INSPECITORS APPROVED BY THE WWI* OFFICIAL. 10. ALL FORK DOW %N.- BE N GOEORMANCCE NTH 11E AFFR TED PLANS AN7 PRO. EGT SPECIFICATIONS. THE APPROVED, PERMED, STAM'ED FLAWS ARE TO REMAIN ON SITE AT ALL TIMES IL DIEM* ARE TO FACE OF STUD, CONCRETE, OR MASONRY UN.ES6 Ofl€RYISE NOTED 12. DO NOT SCALE DRAI1 SS; ME MSION5 6OMM. 13. Yet GONSTR/CTION DETAILS ARE NOT SHON4 OR NOTED FOR ANY PART OF DE HON , DETAILS SHALL BE THE SAYE AS FOR ODER SIMILAR YORK. IF QUESTIONS CM NOT BE RESOLVED IN THIS MAWR, CONTACT TIE ARCHITECT PRIOR TO PROCEEDD5. 14. 6EIERA L CONTRACTOR SHALL PROVIDE OMR YON DETAILED CRITICAL PATH SCI LE FOR REAM NV APPROVAL PRIOR TO START OF COTZTRUCTION UPDATES OF sawn SHALL BE MADE AS 1EGE56SARY rem COPIES PROVIDED TO OM R. 15. ALL FORK A1NV MATERIALS SHALL. BE IN FULL ACCORDANCE YIH 11E LATEST RIES ATV REOLATIOt5 OF THE Aiiat ATONAL WLDNS CODE, NATIONAL f.EGIR!GAL CODE AND ALL OTDER APPLICABLE STATE OR LOCAL LAYS AN) RE6ULA11ON15.140TH IN& IN 1}ESE DRANNS515 TO BE MIRED AS TO PERMIT I'M WTGH 15 NOT COWORIINS TO 11E PREV$OI LISTED CMS- *. PROTECTIVE 1'MM SHALL BE TANN BY DE CONTRACTOR TO FROTECT ADJACENT PROPEft1Y AT ALL Ti:ES DURINS CCtSTRICTiON. 11. 11E GOKIRAGTOR SHALL GO R.Y NTH ALL MST A°PLIGABLE LOCAL ORDINANT6 FOR UTIL.HTY SERVICES. lb. LIGHT AND VENTILATION SHALL GORILY NTH SECTION 120, 1204 1 1205 M. FIRE IXOGKING 5P'LL BE PROVIDED AT ALL FRAIL HALLS AT LO'-O' O.G. AO ALSO AT ANY LOCATION YiI MALL FM* FBCIRAIE5 GBLIN5S REFER TO IBC SEC. 109 FIRE ELOCsCQ S AM? DRAFT STOPS FOR CON5TRUCT10N 20. ALL MTEZ FLXIIMS MT COMPLY 1�Ti H RAC 51- 2b-180 MATER CO GERYATIGN MAR ANY maxims FrAcceMA%E 5TA1'DADS 21. Y+lEN CHANGES TO THE WAWA SYSTEM REWIRE A YECHHAICGAL. FEINT THEY SHALL GORILY NTH THE M05T ORVIT INFORM IELHAVGAL CODE AID NTH AVY LOCAL .1. RI5DCTION RW I.REN'NTe S. 22. PROVIDE LL.IMKATED EXIT SI6NA6E AT ALL RECURS) EXITS. 23. PATCH AND REPAR ALL DUSTIN& MAL.t.S FLOORS AV G51.11166 MAT ME ADAM TO AV) AFFECTED BY WM CONSTRICTION. 24. CONIRAaat 5 TO COMPLY 4T11 CHAFER 33 OF TIE INTLRH M10NAL BUMS CODE G0W 16 PROTECTION OF FWE5iRIANS DIA16 GONS1RlUGT 25. PRIOR TO FIN& INSTECTIat A GERfiFICATE CF GOOI JGTION GOI SiAALL BE READY FOR THE MOTOR. THE CERTIFICATE SHALL STATE'S UPON PBSONAL KIVAED6E, THAT DE P Z APPEARS TO Me BEM F NFORK D, AVD THE MATEI1ALS I »i IN5TAILLE D WEAR RI EVERY MAMMAL R FELT E CON'LWICCE NiH 1W FLAW'. TIE =MATE MU6T E!E WED BY OW OR 1/CM OF TT€ FOLLOYV1i5: (A) Oiler I'W 6•WERPL CONTRACTOR (C) AN APPRO E VDE14f 1ti5PFGTOR OR ItemcroN AMC( 2E. ASBESTOS Alta HAZARDOUS MSTE WAWA TIC ARGIL +EGT FM( STATES, kV DE OftER ACMCf'.ED6E THAT 11E AROITECT HUl5 K4 PRTMON►1L. LIABZ. TTY OR ODER INSRAVX, Ulm 15 (MILE ILE TO RFACNAllY OBTANT 9ICH 06.RAMCE) FOR GJl'k5 AZWiS OUT OF 1W FBRfORMANYCF_ CF OR DE FAAURE TO FUTON ��r€ �VK DISU VC ! O~ETC�GTL MIT M ED TO, 'RE P�'AQA110N CF W �, DENS, VRr�/F65, AND 9T:CPGATIGI�fi, AND PROJECT DIRECTORY ARCHITECT /CONTACT: TENANT: BUILDING OWNER: GENERAL CONTRACTOR: PARCEL It: GRAFT ARCHITECTS, PLLG. 1132 FIRST AVENUE, STE. 408 SEATTLE, WASHINGTON 18101 AIRGAS INC. 1011 ANDOVER PARK EAST TUKWILA, WA 18188 PROLOGIS 23215 66TH AVE S. KENT, WASHINGTON 18032 SIERRA CONSTRUCTION 11100144TH AVE, NE WOODINVILLE, WA 18012 VICINITY MAP :=Itketrsr 3, fie 02C0611•Quelthe. SITE PLAN I' : SD' -0' • EST OFF,GE AREA 3) EXIST 14 (5) TOTAL FLOOR AREA - OGOPAANGY SFPAQA1 Q : EXIT REWRBOT W VA) arta MR CIEE TOW. ZOIlN6 8i5TnT: CODE mat CON5TRIUCWX OCOPA NCf GLA56F1CATIO: UEE STORAGE NV D'iSTR IO!1 TYPE OF waT'.�IGT10Ht SPR1414ER SYSTEM.: 2623041106 LEGAL DESCRIPTION ?LLG P E AREA: BASIC A'LL+OMELE I ALP G AREA: MATED Paw. . FLOOR ACAS Cf 0 AREA 230 SD FT 1,425 50 FT 14855 50 FT 0 16280 50 Ff sa&Y CODE RA T: 5C(E OF AM NOT' TO AFFECT G8'T6Y CODE MO. aoi B: y FAMED 1 3 4 11061RIAL 2003 ECM COTE 1BVAVf 114 �5a _ IIE' ORLKLBED) FILLY BUM =PAW /100=5 1500 =30 45 PEOPLE WOW WAVE() Tii A2.I A3.I 262304 106 POR SE OF SE }BEG AT SE COR SD SUS TH N 87 -44 -08 W 949.49 FT TH N 01 -47 -29 E 185.61 FT TO TPOB TH CONTG N 01-47 -29 E 362.16 FT TH ALG A CURVE TO RAT RAD OF 300 FT ARC DIST 90.34 FT THRU C/A OF 17-15-14 TO N LN OF SOUTHCENTER INDUSTRIAL PARK BEING THE N W OF TR UNDER AUD FILE /6034786 TH S- 88 -12 -31 E ALG SD N IN OF SOUTHCENTER INDUSTRIAL PARK 474.57( -- FT TO W MGN OF ANDOVER PARK EAST TH SIMLY ALG A CURVE TO LFf ON SD W MGN THE CENTER OF WH BEARS S 69 -09 -36 E RAD 330 FT ARC DIST 109.71 FT THRU C/A OF 19 -02 -55 1H S 01 -47 -29 W ALG SD W MGN OF ANDOVER PARK EAST 344.01 FT TO NE COR OF TR TO NORDSTROM BEST REC 1770520 0140 1H N 88-08-21 W ALG N W OF SD NORDSTROM BEST TR 470 FT TO TPOB CODE /ZONING INFORMATION 104-SEPARATB7, IN241EU: FEZ 2003 EC 3023J Contact: Phone: Fox: Contact: Phone: Fox: Contact: Phone: Fox: Contact: Phone: Fax: SEAN NEWTON (206) 120 - 1001 (206) 120 -2141 SEE OMR ..LIE GHAN (253) 520 -0811 (253) 851 -1801 JARROD COOPER (425) 481 -5200 (425) 481 -5210 ME COPY - Piermit No. Men revlM•, ; ---;rl Is subject to errors and =Wont Soprowl c: - : :t c :� does Vie ���'::•- - - . __ not Borne tl - - 1 mde cr crdinancI Reodpt of ark: : ' r _ - ...._ b cdmo vledged: C1 .. -- Datc: . 3 -I - City of 1Ukvwila BUILDING DIVISION FEB 2U _,�, GETE;RAL. II ?ORMATION DEMOLITION AMP FLOOR PLANS DETAILS • RE SEPARAT- PERMIT r.= `=TZ.:D FOR itlechankal VElectrkal Y ang VGe s aping City of Tukwila BUILDING DIVISIONI BEWSICINS t 3 chnages shall be made to tho scopo t- it#icut prior 42.: rotT1 C:' ,.o i c': i rV. :.cT.s wi.I require a nC rzn £ . :; and OW include additional plan review lees. O R D EX INDEX OF DRAWINGS arvo Ff8 o 2W ?; POW C - -� "STATE OF Vas.! a r c h i t e c t s PROJECT NO. 2245.06 air COVER WEFT DRAWN BY. SR COECKED BY. KLK £1:i D4iprsI AMI• U&U5lis The Global Distribution Solution 47775 Fremont Boulevard Fremont, California 94538 Phones 510-656-1900 Fax' 510 -681 -4033 02:06/07 DAM 8>E£T T L 1 • t a • • 1/8" = 1 -0" FIRST FLOOR DEMOLFIION PLAN • A - - 1 1 /8" = 1' -0" 1 /8" = 1.�. • • L REFLECTED CEILING PLAN FIRST FLOOR OFFICE PLAN KEY NOTES: EXISTING DOOR AND FRAME TO BE REMOVED MD RELOCATED. EXISTING OFFICE PARTITION MD FLOORING TO BE DEMOLISHED, D15PO5E OF ALL DEBRIS. O3 EXISTING DOOR MD FRAME TO BE REMOVED AND DISPOSED OF. - INSTALL NEW LIGHTING PER OWNER RECOMMENDATION. EXISTING EXIT TO REMAIN REPAIR AND REPLACE ANY DAMAGED GRID $ CEILING TILES. EXISTING 2X4 LIGHT FIXTURES TO BE GLEANED AND ANY BROKEN BILBS REPLACED. EXISTING DOOR HARDWARE TO BE REMOVED AND REPLACED WITH NEVI LEVER STYLE OPERATING HARDWARE. REFER TO ANSI 4042.6. SEE DOOR NOTES AND DETAILS 4, 5, 4 6 ON SHEET A3.I. INFILL ORIGINAL DOOR OPENING WITH NEW WALL TO MATCH EXISTING ADJACENT. RELOCATED DOOR MD FRAME. ADD NEW CEILING GRID ABOVE NEW HALLWAY MATCH EXISTING ADJACENT. LEGEND= Pol g-1 EXIST. WALLS / PARTITION TO REMAIN EXIST WALLS / PARTITIONS TO BE DEMOLISHED NEW PARTITION • EXISTING DOCK -HIGH DOOR • GENERAL NOTES, EXISTING RAIL DOOR ``')L � ...•:r- • <<. • I. Al.! EXISTING 13UI1DIN6 •OW+5, EXTERN WALLS, EXTERIOR MOM, AND STIRGIUML ER5 TO REMAIN. 2. ALL NEW PARTITION WALLS TO RECEIVE SMOOTH WALL FINISH. PANT, RIABBF..R BASE, TO MATCH EXISTING. 3. CGIFIRM OPERATION OF EXISTING EXIT LIGHTIN9 A� SI6NA6E; REPAIR OR REPLACE AS NECESSARY. 4. `Eh( PAINT ON ALL INTER/OR WALLS MATCH EX 5TiK6. 5. 1 W CARPET IN OFFICE MD SHCORGOK. 6_ VCT 14 REST ROOM5, BREAK, AND STORAGE 1_ COV,RM OPERATION AND LOCATION IGN OF EAST. E N GYYpP�ATHWAY LIGHTN AND I RZ 5MRS, Rt'PAIR, �I. OR feALLOCATE AS MCMSARY. e0 AMNIA FEB 0) 8 CO? 1 - • REVISIONS. ea KATHRYN '! STATE OF W; r-:; ; •. a r c h i t e c t s PROGT NO. 224 GREET lm.EI FLOOR PLAN, RCP b DEMOLITION PLAN DRAWN 8Y• SN CHECKED BY. NBC Ii..I.a D �e�i wMI II 0+ neir r us.ussom, The Global Distribution Solution 47775 Fremont Boulevard Fremont, California 94538 Phones 510- 656 -1900 Fax. 510-661-4033 DA?6 02/06107 9!$T• A2 • TYPICAL DOOR HEAD Seale: S'z1' -0 TYPICAL DOOR JAMB SGale: 3' =I I-O' C DOOR AND TRIM i • u • V �— WALL TYPE AS SCHEDULED y s 1 c DOOR AV TRIM coax AVTRIM - DOOR AND — WALL TYPE AS SCHEDULED IX4WObD CASING �FMSH TO MATCH EXISTING 5/8' 61A6 • IX2WOOD CASING FINISH TO MATCH EXISTING I 1/4' WOOD JAMB 1/2' Y OOD STOP 1 3/4' WOOD DOOR AS SCHEDULED 5/8' 6WB I 1 /4' WOOD JAMB 1/2' MOD STOP I 3/4' MOD DOOR AS SUULED CARPET DOOR TRAN51110N STRIP TILE (QT) DOOR r FLOOR FINISH MAIL SAK ON BOTH SIDES 1/4' OF OPE1tN RAIL FLOOR MAIL DOOR lRAW. ` 51!ZR CPT REDIZER STRIP CARPET SILL/FLOOR TRANSON DOOR NOTES: I. ALL DOORS w/ A LATCH SET OR LOCK SET SHALL HAVE LEVER TYPE OPERATING HARDWARE. 2. ALL FINISH HARDAARE SHALL BE FULLY ACCESSIBLE. REFER TO ANSI 404.2.6. 3. INTERIOR LOGK5ET5 TO BE HEAVY DUTY CYLINDER TYPE. 4. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION PER IBC 1008.1.85 5. ALL DOORS PV CLOSERS SHOULD CLOSE IN A MIN 3 SECONDS FROM AN OPEN POSITION. b. COORDINATE LOCKS 4 KEYING WITH OWNER. FRAME TYPES 3' -4' 7 2 I: WOOD FRAME, SIZE TO FILL OPENING. • A 1 ! ill l 111 lilll1111111111111111011llllllIIIIIIIIIII 4 - $12 6A. SEISMIC SPLAY BRACE AIRES 2 - $1214 6A %RENS STUDS TO T-BAR lir POP RIVET ALL HALL ONE WALL ANGLE 5GIEDULE MAX. HT of COMPRESSION STRUT SW SIZE 4 6A S .E STUD PG(LE 51UD I- 518'x20 6A 56 1.- 11 2-1/2' x 20 GA 55 1 -1' I6'-b' 3-1/2' x 20 GA 55 1'-4' 22'-1' 15/8' x 20 GA WC 10' -0' 114? NOTE: ATTACH UOIALE MO VfB TO FLANGE VV! *6 SCREW 0 l8' O.G. SUSPENDED CEILING DETAIL NTS • X12 GA VERTICAL MIRE HORIZONTAL STRWI TYPICAL CONTIMk US 1 BOARD PROVIDE V2' SPADE OPPOSING MAIN RIMR OR CROSS TEE WALL INFILL PARTITION WALL 2 ivr.ra • 111111 11111 IIIIIII III111IIIIII111111111111IIIII EXISTING MU- t WILL FALL �- Mn. snb COMMON STRUT. FOR SIZE I NO. Sff 5GfD. Bq.ONI ATTACH • PURI.M ABOVE W 2* SHr MiL SGRB15. DOW ATTACH TO 511FFB6t5. CJ's' 6C W1 ST - JOINTS MTL STUD FRA vE TO MATCH EXISTING W R-i9 BATT INSULATION MTL STUD RAWER ATTAC.i'ED TO EXST. CM. SLAB W►' 502' DA. LOW - VELOCITY POitER-DR/Vei FASTENER N I I/4' PeCTRATIO N MN. PER STUD M V.PAGTAFRS . E AT:•0 6 • SUSPENDED CEILING NOTES: NOTE: SEISMIC REQUIREMENTS FOR SUSPENDED CEILINGS REFERENCE CISGA (CEILING 4 INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION) 'SEISMIC 3 -4 GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT4IJNG SUSPENDED CEILING ASSEMBLIES' AND ASGE (AMERICAN SOCIETY OF CIVIL ENGINEERS) 1-02 'MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES' q.6 A HEAW DUTY T-BAR GRID SYSTEM SHALL BE USED PER IBC 104.11 AND 104.11.1, ARMSTRONG'S 'PRELUDE XL' SUSPENSION SYSTEM SHALL BE USED. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE IS ALLOID TO BE 1/8' *EN AN ARMSTRONG BERG2 CLIP 15 USED AT THE TWO UNATTACHED WALL ENDS WITH A CLEARANCE OF I/2' TO 5 /8'. THE OTHER TWO ADJACENT WALL ENDS SHALL BE ATTACHED. THE STABILIZER BARS AT THE PERIMETER ARE ALLOWED TO BE ELIMINATED. FOR CEILING AREAS EXCEEDING 1000 SQUARE FEET, HORIZONTAL RESTRAIN OF THE CEILING TO THE STRUCTURAL SYSTEM SHALL BE PROVIDED. THE TRIBUTARY AREAS OF THE HORIZONTAL RESTRAINTS SHALL BE APPROXIMATELY EQUAL. RI61D BRACES ARE PERMITTED TO BE USED INSTEAD OF DIAGONAL SPLAY WIRES. BRACES AND ATTACHMENTS TO THE STRUCTURAL SYSTEM ABOVE SHALL BE ADEQUATE TO LIMIT RELATIVE LATERAL DEFLECTIONS AT POINT OF ATTACHMENT OF CEILING GRID TO LESS THAN I/4° FOR THE LOADS PRESCRIBED IN ASGE 1 -02 4 1.6.13. FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET, A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SQUARE FEET SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSES ARE PERFORMED OF THE CEILING BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES WHICH DEMONSTRATE CEILING SYSTEM PENETRATION AND CLOSURE ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ADDITIONAL MOVEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES IN ACCORDANCE WITH ITEM B AND HORIZONTAL RESTRAINTS OR BRACING IN ACCORDANCE WITH ITEM C. EXCEPT VIHERE RIGID BRACES ARE USED TO LMT LATERAL DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST I INCH IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE I INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS ARE PERMITTED TO BE PROVIDE AT THE TOP OF THE SPRINKLER HEAD EXTENSION. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. SUSPENDED CEILINGS SHALL BE SIECT TO THE SPECIAL INSPECTION REQUIREMENTS OF ASCE 1-02 SECTION A.133. REQUIRED PERIODIC SPECIAL INSPECTIONS DURING THE ANCHORAGE OF SUSPENDED CEILINGS. 3/4' CST, STUDS, OR WIRE ® 6' -0' O.G. MAX. SECURE TO STRUCTURE A80VE 4 FLATTEN TO ATTACH TO STUDS PER MF'R'S REGONNDATIONS 4 TO MEET IBC SEISMIG REQUIREvENTS R-21 BATT INSULATION 6PU O/3-V x i- ', 25 6A MTL. STUD FURRING 24' O.G. MAX I/2' DEFLECTION (L240) YV R I1 BATT I10t* ATION W/ FSi- 25 VAPOR BARRIER NERF. EXPOSED A9 AT WARM WALLS PROPPED ACCVSTICAL CEILING MTL STUD MINN ATTACHED TO EXST. LANG. SLAB IV 5/32' DA. LOW - VELOCITY POPER-DRIVEI FAS rT1L' . W/ 11/4' PE (RATION MN. PER STO M,AN AGTUR."R RECOnl NDATIONS L JLi 1 ' r•• t . a ,. a . • , r oc „ E . OFFICE PAR11T1ON WALL ( � ivr. ra WALL TYPES a .. FEB 25 • pL 60jEcT P . 2245.06 1a FEB 08lt1 PERIAETCENTEFI • KATHRY: i i • -. STATE OF SHEET TRLS WALL TYPES AM DUALS DRAWN BY. SN CHECKED BY. KMC •ial d ItISA •� j' r I U &U5I mf The Global Distribution Solution 47775 Fremont Boulevard Fremont, California 94538 Phones 510 -656 -1900 Fax' 510- 861-4033 DATE 02/'06107 .A3.1 I