Loading...
HomeMy WebLinkAboutPermit D07-087 - FATIGUE TECHNOLOGY - STORAGE RACKSFATIGUE TECHNOLOGY 455 ANDOVER PK E D07 -087 Parcel No.: 0223400060 Address: 455 ANDOVER PK E TUKW Suite No: Tenant: Name: FATIGUE TECHNOLOGY INC. Address: 455 ANDOVER PK E , TUKWII,A WA Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST , RENTON WA 98057 Phone: 206 818 -4488 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us Owner: Name: KIRKPATRICK FAMILY L L C Address: 88 VIRGINIA ST #7 , SEATTLE WA 98101 Phone: Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH SPF:I;I' , RENTON, WA 98055 Phone: 206 255 -0500 Contractor License No: NORTHWH275JF DESCRIPTION OF WORK: INSTALLATION OF NEW PALLET RACK FOR STORAGE OF METAL WORKING MACHINES AND TOOLS AS WELL AS STEEL STOCK. Value of Construction: $3,600.00 Type of Fire Protection: Type of Construction: DEVELOPMENT PERMIT Fees Collected: $203.19 International Building Code Edition: 2003 Occupancy per IBC: * *continued on next page ** Permit Number: D07 -087 Issue Date: 04/05/2007 Permit Expires On: 10/02/2007 Expiration Date: 10/09/2007 Steven M. Mullet, Mayor Steve Lancaster, Director doc: IBC -10/06 D07 -087 Printed: 04 -05 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Print Name: doc: IBC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: N The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of ork. I am authorized to sign and obtain this development permit. Signature:. Date:0 7 S;;_ Permit Number: D07 -087 Issue Date: 04/05/2007 Permit Expires On: 10/02/2007 C /t Date: l yi KVp Steven M. Mullet, Mayor Steve Lancaster, Director s permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -087 Printed: 04 -05 -2007 Parcel No.: 0223400060 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 455 ANDOVER PK E TUKW FATIGUE TECHNOLOGY INC. 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 9: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -087 ISSUED 03/14/2007 04/05/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available D07 -087 Printed: 04 -05 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D07 -087 Printed: 04 -05 -2007 City of Tukwila Signature: doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: r ( kK dr- Ptrt.S 00-) Date: ! (5 /c 7 D07 -087 Printed: 04 -05 -2007 toc Tenant Name: 4 T.Ge- A,to /, ..Lt Site Address: C Property Owners Name: Mailing Address: go Name:• k _ 7. Mailing Address: /160 S. W • 7u` ST. E -Mail Address: !M S OPelItJ'GN !? Ltl it s - LO ✓v� NFQRMATI Company Name: Mailing Address: /100 w• 7 F e .12,4 gds 7 City State Zip / "` Contact Person: l � J4 c�t9�.li. -'c # Day Telephone: a06 Per p► Z '` '1t�tr E -Mail Address: vvi SOf 561 /1 (. vi cr (its 6dwi Fax Number: 12 ad-g 69 Vt Contractor Registration Number: n6 C"' f '� tai 475 0 Expiration Date: l 0 (9 ,e 7 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** wet stamped Company Name: Mailing Address: Contact Person: E- ress: Company Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ENGINEER OF' All plans must be wet stamped biEngineer of Mailing Address: l (a„ (u, mid 4, J- y ` ! /D9� '' City State Contact Person: � / e7 �41oI Day Telephone E -Mail Address: • ■appticatimu\permit application (1 -2003) 1/2003 Page 1 Suite Number: k i' city King Co Assessor's Tax No.: h A9 3 yt:9 c0 Floor: New Tenant: .... Yes t,9- 98/ Pd� State Zip Day Telephone: . ZO - cp' E ^ Ciljtf8 1 /-) t TR' °s 7 City State Zip Fax Number: 1 7 1 ,75 -- P- 8' G 9 Le6 State Zip City Day Telephone: Fax Number: z Fax Number: ?a a"'o - �8�3 ,G FE RMI' Valuation of Project (contractor's bid price): $ 3 6 d v Existing Building Valuation: $ ---- Scope of Work (please provide detailed information): tn, `/, O ��0�� lY. t ! ' ,s r' Of riAded Gvcr4i.ec j* t4r i f 4n de 7 CS Lae Gt S 51(491 hck• .cPe . Will there be new rack storage? ❑...Yes Provide A11 Building Areas in Square Footage Below Floor 2 ° Floor 3` Floor_ . Floors. th ......................... Basement ....... ..._ ........................... _ .. ..........................._... ........ ............................... . Accessory Structure *. Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck .._ .. ............................... _........... Existing ' qt. /a Addition to Existing Structure Type of ConstructiOtt per UBC Type of Occupancy.per UBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes _No If "yes ", explain: Cog Sprinklers ❑...Automatic Fire Alarm ❑...None 0,,. Other (specify) +emir (,via/ kje/ Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes v ..No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. FIRE PROTECTION/HAZARDOUS MATERIALS: UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water ❑ . City of Tukwila Water District ❑ .. Water District #125 ❑... Highline Water District 0... Cit of Renton Water District Sewer ❑ .. City of Tukwila Sewer District ❑.. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) \applications\permit application (1- 2003) 1/2003 If "yes ", see Handout No. Page 2 for requirements. UIC WQRKS PE RMIT I•`erlttMA'I'ION - 206= 433 179 Scope of . ork (please provide detailed information): Street Use: ❑ .. Street Use Storm Drainage: ❑ .. Storm Drainage Land Altering and /or Hauling: ❑ .. Land Altering: ❑...Cut Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: ■appliationslpetmit application (1 -2003) 1/2003 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑...Chan l ization/Striping ❑...Flood Control Zone Water ... Call before you Dig: 1 -800- 424 -5555 0.-.Curb cut/Access/Sidewalk cubic yards 0... Fill cubic yards ❑ .. Hauling City Sewer ... ❑ Sewage Treatment Page 3 City Sewer Information: ❑ . City of Tukwila Sewer District 0.. Val Vue Sew District ❑...City of Renton Sewer District ❑ .. City of Seattle Sewer District ❑ .. Sanitary Side Sewer ❑ .. Sewer Main Ext • Sion ❑ .. Private ❑ .. Public Water Information: ❑ .. City of Tukwila Water District ❑ .. Water District #125 0... Highline Water District 0... City of Renton Water District ❑ .. Water Main Extension ❑ .. Private 0... Public ❑ .. Water Meter/Exempt: Size(s): ❑ .. Deduct 0... Water Only ❑ .. Water Meter Permanent #: Size(s): ❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons ❑ .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation ❑ .. Miscellaneous: Day Te •hone: State Fire Line ....0 Zip Day Telephone: e Zip Unit Type: Qty Unit T . e: Qty Unit Type: Qty Boiler/Compressor: Qty Furnace <100K BTU Air .i dling Unit > 0,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU vaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Co s g System Incinerator - Domestic Air Han a ' g Unit <= 10,e.0CFM Incinerator — Comm/Ind 'Mitt i MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: **An original or notarized copy of current Washington State Contractor License must be prese ed at the time of permit issuance** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... Commercial: New .... ❑ Replaceme ther: Fuel Type: Electric Gas ....0 Indicate type of mechanical work being install and the quantity below: City State Zip Day Telephone: Fax Number: Value of Construction — In all cases, a value of construction amount shou d be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR ENT: Signature: Print Name: Mailing Address: / /(. .SGV 7 'T, Date Application Accepted: \applications\permit application (1 -2003) 1/2003 65/H Io1- rm Date Application Expires: Page 4 mil Date: /i/ 7 Day Telephone: A96- g1S' 2 A T.t/� q�.-' 7 City State Zip Staff Initials: Receipt No.: R07 -00368 Initials: JEM User ID: 1165 Payee: MICHAEL J. SORENSON ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0223400060 Permit Number: D07 -087 Address: 455 ANDOVER PK E TUKW Status: PENDING Suite No: Applied Date: 03/14/2007 Applicant: FATIGUE TECHNOLOGY INC. Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 6847 78.27 Account Code Current Pmts 000/345.830 78.27 Total: $78.27 Payment Amount: $78.27 Payment Date: 03/14/2007 03:11 PM Balance: $124.92 57 ?2 L. )3/1 ,7716 ,_ M . : doc: Receipt -06 Printed: 03 -14 -2007 Payee: MICHAEL J. SORENSON ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0223400060 Permit Number: D07 -087 Address: 455 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 03/14/2007 Applicant: FATIGUE TECHNOLOGY INC. Issue Date: Receipt No.: R07 -00518 Payment Amount: $124.92 Initials: JEM Payment Date: 04/05/2007 02:55 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 6861 124.92 Account Code Current Pmts 000/322.100 120.42 000/386.904 4.50 Total: $124.92 doc: Receiot -06 Printed: 04 -05 -2007 Project: Type of Inspection: Address: Date Called: — ` yS i *7' "- Special Instructions: Date Wanted: .s a.m. ( 4 2 3 Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 gl Approved per applicable codes. Corrections required prior to approval. COMMENTS: � -1) 6 .1 El $58.00 EINSPECTIOF� EE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit Ogg PERM )431 -36 NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: /P . Address: A 5 4 e,w', v/t'f Special Instructions: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Type of Inspection: Date Called: Date Wanted: -- Requester: x/21 //- (206)431 -3 a. Phone No: ? - 8/8 Corrections required prior to approval. COMMENTS: 'Inspector: ni $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: !Date: Project: r", - G u E �fr/U1_vG 7 ,,, Type of Inspection: lei- e_ '4_ Fire Alarm: Address: LIss A PC Suite #: Contact Person: Mtge" �5od Ai Special Instructions: Phone No.: zo6.- g/G - l /zlgg Permits: Needs Shift Inspection: Sprinklers: Y Fire Alarm: `/ Hood & Duct: N Monitor: vr (- Pre -Fire: (! Permits: fit p Occupancy Type: 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 INSPECTION NUMBER Pi - Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Do? - OS 7-- . . PERMIT NUMBERS I I Corrections required prior to approval. COMMENTS: � 'Cg X10 4 D4? Inspector: Date: Lib v /0 7 � Hrs.: j � $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from I\ the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 OTTO ROSENAU & ASSOCIATES, INC. 18 April 2007 City of Tukwila Building Department 6300 Southcenter Blvd, Suite 100 Tukwila, Washington 98188 -2544 Project: Fatigue Technology - 455 Permit Number: D07 -087 Address: 455 Andover Park E Job Number: 07 -213 We herewith certify that we have completed the following special inspections. To the best of our knowledge, the work inspected was in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. All typewritten reports have been mailed to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and /or details of the building. Items inspected are: 1. Wedge anchors (for pallet racks) Sincerely, OTTO ' OSENAU & ASSOCIATES, INC. Jeanne L. Pnrvin cc & fax c: Northwest Handling Systems Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA Tel: (206) 725 -4600 • Toll Free: (888) OTTO -4 -US • Fax: (206) 723 -2221 WBE W2F5913684 • WABO Registered Agency • Website: www.ottorosenau.com • OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing Report Number. 60654 Description: Wedge Anchors CONSTRUCTION INSPECTION REPORT MAY 11 ?00) c oday i v ez Project: Fatigue Technologies 455 Permit Number. D07 -087 Address: 455 Andover Park E, Tukwila Job Number: 07 -213 Client Northwest Handling Systems Client Address: 1100 SW 7' Street, Renton Inspector and Date Remarks Isaac Ruoff Arrived on site to inspect the wedge anchors for the new pallet racks in the southwest corner of the 4/10/2007 455 Building. Upon arrival on site, the contactor had already installed the anchors; therefore I was unable to verify the depth, cleanness, and diameter of holes. Based on the letter code (G) at the top of the anchors, the Hilti KB3 were 4W long. Using a calibrated torque wrench I verified that the anchors were torqued to the required torque as per ICC ER# 1385. Approved plans called for the anchors to be Hilti TZ anchors as per ICC ER# 1917. Conformance pending the engineer of record approval of the wedge anchor change. Copies to: X Client Contractor Architect X Building Dept. Technical Responsibility Engineer David Lyal, Technical Director This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725 -4600 or 1-888-OTTO-4-US - Fax (206) 723 -2221 Form No.: ADM1N -63-01 (Rev 05/03) NORTHWEST HAN D LING SYSTEMS, INC. The Material Handling Experts SITE ADDRESS: TENANT NAME: Fatigue Technology Inc. DATE: March 14, 2007 APPLICANT: Mike Sorenson / (206) 818 -4488 1. Load application and rack configuration drawings attached. CO P Pernitt P 1100 SW 7th St Renton, WA 98055 (425) 255 -0500 ph (425) 228 -6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT - -. 575' REVIEWED FOR Andover Park E. CODE COMPLIANCE A p wr*,n,IpII7!ra► MAR 2 8 l00/ City Of Tukwila BUILDING DIVISION 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored in racks: Metal working machinery and tools as well as steel stock. Non encapsulated, stored on wood pallets and open top wood crates. Records archive storage, records in bankers boxes stacked on wood pallets. 6. Sprinkler System Information: .39 GPM / 5600 square feet. Sprinkler head temperature: 165 degrees. 7. Smoke and heat vents: In place but not required for this size of project. 8. Building exits indicated on attached drawings. RECEIVED CITY OFTUKWILA MAR 14 ?ON PERMITCENTER -tart BY G. OHANIAN DATE. 3-1 -07 SUBJECT STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: FATIGUE TECHNOLOGY PARK EAST TUKWILA, WA. 98188 PER IBC 2003 EDITION STORAGE RACKS CAPACITY: 4000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -11867 RAdK DEOI(414 & EN(INEERI Td do. 412 TIEOT BROADWAY, fiUITE #204 QLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 FILE COPY Perrr..!t No. --..— EXPIRES 12 -26 -07 SHEET NO 1 JOB NO RD -11867 CODE O REVIEWED k A pPn 11Irq ) MAR 2 8 2001 Clty Of TUkwila BUILDING DIVISION RECEIVED CITY OFTUKWILA MAR 14 ?097 PERMITCENTER . :-.tans. _::ze 'Dt .4. BY G. OHANIAN RACK DESIGN & ENGINEERING CO. DATE . 3 -1 -07 412 WEST BROADWAY, SUITE #204 SUBJECT (LENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 N 0) R =4 BRACED S =.85 W =D.L.+ 3 L.L. LOAD PER COLUMN W=.2- 4 L.L. 4.2 K 96 ", 106" & 144" 1 5 15/16" BEAM M _ 144 "x2.2 = 40 "K 8 S =30 K - 1.3 <1.59 _ 3 144 _ SxWxL �+ » 384xI, xE = .62 < 180 — .80 L.L.= 2 x 3x4 K =4 K 3 2 col_ V _ .85x 1x4.2 = .42 K LONGIT. 6x1.4 V _ .85x 1x4.2 = . 63 K TRANS. 4x 1.4 4000 #/ LEVEL +25% IMPACT LOAD 2200 #1 BEAM SEISMIC DESIGN V= Rx1 4 x W IBC 2003, SEC. 2208 S =1.27 (USGS MAP) WORKING 1 =1 STRESS S kis =1.27 (EQ. 16 -38) R =6 MOM. CONN. SOS =-1 x1.27 =.85 (EQ. 16 -40) 44" I.=4.88 S =1.59 F = 50 x51. LONGIT. SEISMIC .42 K SHEET NO 2 JOB NO.. RD -11867 4" BEAM M 106 "x2.2 K = 29 "K 8 S R =4 9 3 "K = .96 <.98 A _ 5xWxL = " < 106 — .59 384xI xE 180 123ZILl 11"K I K =3.36 S =.98 Fy =50 KSI. BY G. OHANIAN RACK DESIGN & ENGINEERING CO. DATE . 3 -1 -07 412 WEOT BROADWAY, SUITE #204 SUBJECT (LENDALE, A. 91204 TEL:(818)24O -3810 FAX:(818)24O -3813 COLUMN ANALYSIS M x- 3" t =.09" 1 J COMBINED STRESS RATIO P + M ax — 15 + = .76 <1.33 a Fy =50 KSI A =.78 S =.80 r =1.2 r =1.1 BASE PLATE ANCH. TENSION = 11— (6;2x3 ") =0 ANCHOR SHEAR = .42 2 = 21 K (2) -1 /2 "9 HILTI KWIK BOLT TZ ANCHORS ESR -1917 OR APPROVED EQUAL. MOMENT AT BEAM CONNECTION 7/16 "v5 RIVET A = .1 Fy = 79 KSI Va = .1x79x.4 3 Ma =3Kx4 "x1.33 = 16 " CONN. 2 PIN CONN. KI _ 56x1.7 _ 79 r 1.2 KI — =47 r — � 52 Y Max = S =24 K 10 "K Fe= ( K �" =45 r x Fn =Fy(1— 4F ) =36 e P =F xA= 28 K P_Pn =15 a— 1 4 ll 2 K ii": SHEET NO. 3 RD -1 1867 JOB NO. 7 3/4 "x5 "x3/8" BASE PLATE BY G. OHANIAN RACK DESIGN Sc ENGINEERING CO. DATE . 3 -1 -07 SUBJECT LOAD TO DIAGONAL F =50 KSI A =.31 r =.48 Q =.74 L= 58" CHECK WELDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K CHECK SLAB 4200 4 2 °' 1000 F 10.6 P = 3.3 K 4.2x144=662 °" 6 —25" M= (12 fx1000x 2 x12 = 1260 "# 5= 12x6 = 72 6 1260 = 18 <1.6 ■200 =80 72 412 WEOT BROADWAY, QUITE #204 (#LENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 OVERTURNING TOP LEVEL LOADING M .63 "x.5x1.15 =122 "K MOT . 21Kx2x168 " =70 "K MR = 4.2 K x44" = 190 "K MR =1.6 Kx44 "= 70 " K NO UPLIFT P = .63 K x2x 5 8 = 1.7 K 44 BOTH SIDES TYP. 18 5" 1� l t =.07" P 1 42001 SHEET NO. 4 JOB NO. RD -11867 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL ACTIVITY NUMBER: D07 -087 DATE: 03 -14 -07 PROJECT NAME: FATIGUE TECHNOLOGY INC. SITE ADDRESS: 455 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Biding Division Public Works PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 511- mu 3 ?01 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator n DUE DATE: 03-15-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: DUE DATE: 04-12-07 Approved with Conditions g Not Approved (attach comments) ❑ DATE: Planning Division Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License NORTHWH275JF Licensee Name NORTH WEST HANDLING SYS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600051641 Ind. Ins. Account Id 32999900 Business Type CORPORATION Address 1 1100 SW 7TH ST Address 2 City RENTON County KING State WA Zip 980552939 Phone 4252550500 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/6/1973 Expiration Date 10/9/2007 Suspend Date Separation Date Parent Company Previous License Next License NORTHHS963ND Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 TRAVS 81S 1 03354822BCM 10/01/2001 Until Cancelled 01/01/1980 $12,000.00 10/09/2001 Business Owner Information Name Role Effective Date Expiration Date FRANCK, JAMES J 01/01/1980 THOMAS, KEVIN A 01/01/1980 KOSTY, CLARK R 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= NORTHWH275JF 04/05/2007 • • 410 • • 7 w E MOW r 1 L 1NW OCICIIPVICN lc" AS SHOWN �" 306 I . 1 4' °""'"" it KEITH WERNER — _ — — -. 901X'P -- — — — MINN -- .* i x1•O _— .I -w — -. — Will — — — — — — 0 - - - - INN -- 4t IXtt 40' RACK LAYOUT � E' C� smi L. ..I ,. , u ,< 1 w Q Fig . ; ; : Ui°4 . ?" 4 ta `° 1 LJ y 3 g =w c � - a ... d, ; 1 c. biro a a o ' d ;1,0. al i 1 11 e 17g7 I. r 121 "h r -n - - ME P —� = — iXttl — — — — H — 0 40' MI= MEP MIIM OF X MIMMON vs X IMMO W X mem GO ememer 0, ac 901X44 901 XPt 901 XP$6 90X44 [ MMI 1E111 ■I MN MO MINI TV I 1 1 1 1 I NORTHWEST 11 n [ r . I: •( 1100 SW 7TH STREET RENTON WA 98055 (425) 255 -0500 40' 96Xbt 96X$6 96X$P 96X1' 96XP$ 96X .p* 96Xft 96XP1s 96X'64 � 96X44 1L96Xtt TV ANCHORAGE PORTLAND SPOKANE EUGENE YAKIMA 96XP$ MOM 96XtP 96Xti4 40' 96X$P WI 96XPP C) .la co 0) '6' r 96XPP PSX4t C) CO � A FATIGUE TECHNOLOGY INC. ;J J i mommi J • • BOTH SIDES TYP. BRACING DETAIL FRONT VIEW 7/16 "0 RIVET ASTM A354 -79 BEAM CONNECTION SIDE VIEW BASE PLATE DETAIL (2) -1/2'0 ANCHOR BOLTS PER BASE PLATE 3 1/2" EMB., (SEE NOTE NO. 4) . t - •• • - • •- _ . • • t - d 4 • . . • • • . . •• • •.. PROXIM FATIGUE TECHNOLOGY 445 ANDOVER PARK L. TL'XWRA. WA. 98188 STORAGE RACK DETAILS ' 10810 ' Ro- 11867 SHEET NO. Cl 96 106" & 144" l • f I • • n N o 44" � • • GENERAL CONFIGURATION EXPIRES 12 -26-07 • REVIEWED FOR CODE COMPLIANCE nonnycn MAR 28 2091 City Of Tukwila BUILDING G 1- DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2003 EDITION AS AMENDED BY OREGON 2 -STEEL FOR ALL SHAPES FY =50 KSI. ASTM A570 -85 GR.50 (EXCEPT AS NOTED) 3 -ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR 1777 (E70)0( ELECTRODES) 4 -ALL ANCHORS HILT! KWIK BOLT TZ ESR -1917 OR APPROVED EQUAL 5- CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6- STORAGE RACK CAPACITY4000 f/ LEVEL 7 -ALL RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD OF 4000 # /I..EVEL 8- STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10' -0" OF HEIGHT RECEIVED CTIYOFTDIGIVILA MAR 14 ?Jr PERMfTCENh V1+-011- (41 REVISION RUCK DESIGN AND ENG1NEERIN( 1 .a �wmAwa.amcnw w CA. n .a�ewe.. DRAVirsuc 8