Loading...
HomeMy WebLinkAboutPermit D07-106 - SPEC OFFICE - TENANT IMPROVEMENTSPEC OFFICE 16040 CHRISTENSEN RD STE 101 D07 -106 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: Contact Person: Name: Address: Phone: 2523049039 16040 CHRISTENSEN RD TUKW SPEC OFFICE 16040 CHRISTENSEN RD, SUITE 101 , TIJKWILA WA MCELROY GEORGE & ASSOC INC 3131 S VAUGHN WAY STE 301 , AURORA CO 80014 VICKI SOMPPI 22002 64 AV W, SUITE 2 -C , MOUNTLAKE TERRACE WA 425 -670 -6706 Contractor: Name: GATEWAY CONSTRUCTION SRVCS INC. Address: 11414 NE 60TH ST , KIRKLAND, WA 98033 Phone: 425 -822 -5178 Contractor License No: GATEWCS992C3 DESCRIPTION OF WORK: TENANT IMPROVEMENT - INTERIOR DEMOLITION, REMOVING EXISTING DOOR AND INFILL, NEW DOORS, NEW RELITES. Value of Construction: $6,700.00 Type of Fire Protection: SPRINKLERS /AFA Type of Construction: VB doc: IBC -10/06 Cit Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT D07 -106 98043 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 03/04/2008 Fees Collected: International Building Code Edition: Occupancy per IBC: D07 -106 05/04/2007 10/31/2007 $289.13 2003 0008 Printed: 05 -04 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Meter: Permit Center Authorized Signature: Print Name: doc: IBC -10/06 City ck.iTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo e o k. I am authorized to sign and obtain this de permit. Signature: ..� �'�v `f„w7C�'i( Date: 6-->g — o 7 N Permit Number: D07 -106 Issue Date: 05/04/2007 Permit Expires On: 10/31/2007 Date: oslog 1 61- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 - 106 Printed: 05-04 -2007 Parcel No.: 2523049039 Address: 16040 CHRISTENSEN RD TUKW Suite No: Tenant: SPEC OFFICE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 9: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D07 -106 Status: ISSUED Applied Date: 03/26/2007 Issue Date: 05/04/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the D07 -106 Printed: 05-04 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 15: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 16: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 17: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 20: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 22: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 23: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 24: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 26: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D07 -106 Printed: 05-04 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -10/06 Print Name: J (1-G- K VI 8 A 1-2 11° City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us /4) Date: 5 ✓ - d - 7 D07 -106 Printed: 05-04 -2007 Community Developmer apartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Site Address: I 6 O 1 O CAI `' road Suite Number: I 01 Floor: 1 Qo Tenant Name: lC� New Tenant: ❑ .... Yes ❑ ..No R R ev � cact t:LC - P aox 516601, 1 -C 4n cs , -CA qo0 1 Property Owners Name: ece 0 h 1 e O +l rOf'e..'lf, es Mailing Address: 1 G'360 a n y Gk. ()LA C 1 S City State Zip CONTACT PERSON wh o dome contact when your permit is ready to be "issued Name: V 1 OY Ip t Day Telephone: �/ Mailing Address: 220052 (a `'1 A 1Q . kJ �'�1-. 2C W?OUYI4 �kO TP. V (e wP1 6 /.3 City State Fax Number: L( ?F) — -77y —zl 1 Zip E -Mail Address: l Ck l S Company Name: • A!. ti: La GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) ¶6D Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: All plans Must be wet stamped` b y Architect of Recor Company Name: ('f)1 1 rt..P (R11.Sly Mailing Address: 22062 Gt4 ►� 1.3 54-e . 2C Contact Person: v 1 Ck 1 50 Wl p01 E -Mail Address: \l I C1C:‘ 5 (n h yl g11ci¢S 1 G1 V1 . CO r1, tamped by Engineer o Company Name: Kik Mailing Address: ` Contact Person: E -Mail Address: Q:\Appliations\Fonns- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 25 3 City Day Telephone: Fax Number: Expiration Date: State wtcurri la Ike. Teem/ w4 q'c City State Zip Day Telephone: (125 ' 6 76 6 7 0 6 • Fax Number: l-{25 777 ' '024'7 City Day Telephone: Fax Number: State Zip Page 1 of 6 Valuation of Project (contractor's bid p‘: $ Scope of Work (please provide detailed information): exisk;y15 OJ/►C, tYlA l( i Will there be new rack storage? ❑.... Yes PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: C Xi �°, Compact: E?`t 341 v1- HandicapEX1 3+i L& Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: it rtvde All Buildin Dotage B:i Sprinklers Automatic Fire Alarm Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doe Revised: 9 -2006 bh Existing,lding Valuation: $ i► 4 0r c - vl6ii - Hoh Y pvivi 12 &4J plr 7rS JJJ Y €) i S . J o If yes, a separate permit and plan submittal will be required. ❑ None ❑ Other (specify) Will there b storage or use of Minim : ble, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes ; attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Fixture Type: " Qty Fixture Type; Qty'': Fixture Type: Qty . Fixture Type:. ! Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING CON!(tACTOR INFORMATION Company Name: Mailing Address: City Contact Person: E-Mail Address: Contractor Registration Number: Q:Npplications\Porms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 bh Day Telephone: Fax Number: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: State Zip Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ► OR 1THO AGENT: Signature: / Date: 3/ /t7 Date Application Accepted: 3 • Lb .01 Q:\Applications\Fotms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: LI25 •6 G led-)Co Apr" 1 Mailing Address: 27,06Z 6 q Ave_ . LA..) S}Q < 1C Wovnflakc WIN ' 13 City State Zip Date Application Expires: ' 12fr •a , StaffJpijials: Page 6 of 6 i RECEIPT NO: R07 -00751 Initials: BLH User ID: ADMIX Payee: UNICO PROPERTIES LLC SET TRANSACTIONS: Set Member Amount SET ID: 0504 SET NAME: CHRISTENSEN RD D07 -091 577.12 D07 -092 614.68 D07 -093 811.16 D(7 1�D5 ; 177.00 TOTAL:" 2,179.96 TRANSACTION LIST: Type Method Description Amount Payment Check 64768 2,179.96 TOTAL: 2,179.96 ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: latp://www.ci.tukwi/a.wa.us BUILDING - NONRES STATE BUILDING SURCHARGE SET RECEIPT Account Code Current Pmts 000/322.100 2,161.96 000/386.904 18.00 TOTAL: 2,179.96 Payment Date: 05/04/2007 Total Payment: 2,179.96 7817 05/04 9716 TOTAL 2179.96 Parcel No.: 2523049039 Permit Number: D07 -106 Address: 16040 CHRISTENSEN RD TUKW Status: PENDING Suite No: Applied Date: 03/26/2007 Applicant: SPEC OFFICE Issue Date: Receipt No.: R07 -00434 Payment Amount: $112.13 Initials: BLH Payment Date: 03/26/2007 01:40 PM User ID: ADMIN Balance: $177.00 Payee: CONNELL DESIGN GROUP City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 14696 112.13 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 112.13 Total: $112.13 dcc: Receiot -06 Printed: 03 -26 -2007 COMMENTS: Type of Inspection: / ev q I \...) ( /. !r / /? // ' - ': )�i / - 7-..,' / Special Instructions: ((( jri m: `-p- Requester: Phone No c a.D6— 786-b3f35 (2, - 0/,- ( /b 4417 Project: _ Type of Inspection: / ev q I \...) Address. /(0<i(, eh., CIAVCoki pate Called: (c( Special Instructions: Date Wanted: _� _ en ' 25 jri m: `-p- Requester: Phone No c a.D6— 786-b3f35 INSPECTION RECORD Retain a copy with permit PY P INSPECTION NO. DO7 - /C-7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION fZ J� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. ❑ Corrections required prior to approval. I . pec or: Dat i 44.4.A. ' : .00 REINSPE ON FEE EQUIRED. Prior to inspection. fee must be aid at 6300 Southcenter vd.. Suite 100. Call the schedule reinspection. eceipt No.: 'Date: Project: . t. (2 /4 z-.. - Type of Inspection: Fire Alarm: Address: / -v [O rH/, yf r )P. S . Suite #: l Contact Person: M: 11.4- IAA 141 {,,-/ Special Instructions: Phone No.: Needs Shift Inspection: s ' ,Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 2 INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 A. Corrections required prior to approval. COMMENTS: r% rz— Inspector: ,5 1, S.( Date: • ) 2 1 l - 7 Hrs.: / _ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ity of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 J Project: S p f , c c- 4 Sprinklers: Type of Inspection: 1H :elf Address: f 6 a s/ 0 CAE 1 rfe ei 6e Suite #: Jo f l'd.. Contact Person: ill ii-c. LIA -t h'r Special Instructions: Occupancy Type: Phone No.: .2.010. 7e6• o3bS Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER pproved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 00°7- /a 07 - SS- /<S7 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 n Corrections required prior to approval. COMMENTS: Oe no l7 " � �il•t,�/ j7`�. 41.1 oil O6-d '/c% C€ L Inspector: 5i _i /c 4 Date: 7/3//07 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 DEPARTMENTS: gs 4wG Building Division N PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -106 DATE: 03 -26 -07 PROJECT NAME: SPEC OFFICE SITE ADDRESS: 16040 CHRISTENSEN RD, STE 101 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued ‘I k' 3. Fire Prevention ) 1 Public Works Structural 5- DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ❑ r,� 3- 21 -0,1� Planning Division ( I Permit Coordinator n DUE DATE: 03-27-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 04-24-07 Not Approved (attach comments) n DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License GATEWCS992C3 Licensee Name GATEWAY CONSTRUCTION SRVCS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602086011 Ind. Ins. Account Id 754100 Business Type CORPORATION Address 1 701 DEXTER AVE N SUITE 420 Address 2 City SEATTLE County KING State WA Zip 98109 Phone 2066219111 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/26 /2001 Expiration Date 3/4/2008 Suspend Date Separation Date Parent Company Previous License NIELSC•02708 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SACCO, RONALD PRESIDENT 02/26/2001 Bond Amount NIELSEN, CRISTIAN VICE PRESIDENT 02/26/2001 SRS 1008614 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 RLI INSURANCE CO SRS 1008614 02/26/2002 Until Cancelled $12,000.00 03/04/2002 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= GATEWCS992C3 05/04/2007 h t I GENERAL NOTES • i ir a • I. ALL CONSTRUCTION SHALL COMPLY WITH THE CURRENT REGULATORY CODES FOR THE STATE OF WASHINGTON AND THE LOCAL JURISDICTIONS. SEE PROJECT DATA SECTION FOR CURRENT APPLICABLE CODES. . CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS. DIMENSIONS, DETAILS, ETC., AND NOTIFY THE DESIGNER OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. CONTRACTOR SHALL VERIFY ALL 'BUILDING STANDARDS' WITH BUILDING LANDLORD PRIOR TO BEGINNING ANY WORK. HOWEVER. THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE DESIGNER'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGNER HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS, ADDENDA AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES WHiCH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOiSE, STEAM, SMOKE, VIBRATION, HAZARD OF OTHER CAUSES. IN ADDITION, THE TOR SHALL MINIMIZE DISRUPTIONS OF ADJACENT TENANTS DUE TO NOISE, ODOR, CORRIDOR FUMES OR VIBRATION. ALL COMMON LOBBY AND CORRIDOR SPACE SHALL BE KEPT CLEAR OF DUST, DEBRIS AND CONSTRUCTION MATERIALS AT ALL TIMES. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 8. ALL DIMENSIONS ARE TO FACE OF GYPSUM WALL BOARD UNLESS OTHERWISE NOTED. 4. WHERE CONSTRUCTION DETAILS ARE NOT SHOPIN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK IN THE SAMiE BUILDING. 10. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT 15 INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. II. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF HIS WORK. 12. THE CONTRACTOR WiLL VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. 13_ THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE 13UILDING AND SITE WHILE JOB IS IN PROGRESS AND UNTiL THE JOB 15 COMPLETED. 15_ ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONb (1) YEAR AFTER COMPLETION, UNLESS OTHERWISE SPECIFIED AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS AND DISCREPANCIES ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE IS GIVEN. 16. LATHING, PLASTER AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO THE CHAPTER 25 OF THE 2003 I.B.C. I7. ALL EXPOSED GYPSUM BOARD TO HAVE METAL EDGES AT ALL - CORNERS AND WALL INTERSECTIONS_ 18. ALL GLASS AND GLAZING SHALL COMPLY WITH THE 2003 i.B.G._ AND THE U.S. PRODUCT SAFETY COMMISSIONS: SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS. i4. ALL REQUIRED FiRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. 20. EXIT SIGNS AND ILLUMINATION SHALL CONFORM TO THE 2003 I.B.G. CHAPTER IO AND LOCAL FIRE MARSHAL REQUIREMENTS. 21. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOW..EDGE OR EFFORT. 22. FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATIONS WITH THE FIRE MARSHAL. CONTRACTOR TO SUPPLY FIRE EXTINGUISHERS AND CABINETS AS REQUIRED_ 23. ELECTRICAL ROUGH -IN AND REFLECTED CEILING PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR EXACT LOCATIONS SHOULD BE VERIFIED. 24_ FLAMMABLE LIQUIDS SHALL NOT BE PLAGED, STORED OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN NPPA. STANDARD 30 AND THE CURRENT UNIFORM FIRE CODE_ PERMIT MAY BE REQUIRED_ 25. ALL DRAPES, HANGINGS, CURTAINS, DROPS AND ALL OTHER DECORATIVE MATERIAL, INCLUDING CHRISTMAS TREES THAT WOULD TEND TO INCREASE TIE FIRE AND PANIC HAZARD SHALL BE MADE FROM NONFLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT SOLUTION OR PROCESS APPROVED BY THE COUNTY FIRE MARSHAL_ PROVIDE A CERTIFICATION TO THIS EFFECT_ A. EXIT DOORS, EXIT LIGHT' AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. B. MINIMEIM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER THE 2003 I.B.C. 26. ALL LAY -IN ACOUSTICAL CEILING GRIDS SHALL BE INSTALLED AND SECURED PER THE 2003 I.B.G. STANDARDS FOR EARTHQUAKE ZONE D AS ME 0635, C636. 27. PROVIDE OR M100IFY AS NEED SPRINKLER, ALARM AND SMOKE DETECTION SYSTEM PER APPLICABLE CODES, WADDING IF NECESSARY FiRE HORNS, STROBE LIGHT'S, CONTROL PANE. CONNECTIONS, SMOKE DETECTORS, AUDIO VISUAL ALARMS_ SUBMIT SHOP DRAWINGS TO THE FIRE MARSHAL FOR APPROVAL. 28. TENANT TO PROVIDE AND INSTALL THE TELEPHONE AND DATA COMMUNICATION CABLING. CONTRACTOR TO COORDINATE SCHEDULING AND OTHER W.QUIREt 4TS WITH TENANT. 24. MECHANICAL SYSTEM: CONTRACTOR SHALL VERIFY AND PROVIDE A COMPLETE H VAG SYSTEM MRCH CONFORMS TO THE OWNERS HVAG SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ROOF PENETRATIONS AND PATCHING. AN1' SOREDANG OF ROOF - MOUNTED MECHANICAL UNIT REG/VIREO BY 6OVEFILINE. .NRISOICTION. 30. PROVIDE OR MODIFY AS NEEDED E•ER6FNGY LIGHTING. 31. ALL ITEMS MARKED 'NUG.• ARE NOT PART OF THIS CONTRACT. 32. ABBlE1VIATiONE.SS THROUGHOUT THE PLANS ARE ABBREVIATIONS MUCH ARE IN COMMON USE THEE LIST OF ABBREVIATIONS PROVIDED IS NOT MENDED TO BE COMPLETE OR REPRESENTATIVE OF CONDITiONS OR MATERIALS ACTUALLY USED ON THE PRO..EGT. THE DESIGNER WILL DEFINE THE INTENT OF ANY IN GUESTiON. ' 33. D0 NOT SCALE DRAMIYGf . IF A Dt SION DISCREFBIGY IS NOTED, CONTACT DESIGNER. 34. IF a*L.DINe STANDARDS HAVE MDT BEEN ESTiIBL1ED OR HiAVE SEEN ESTIELISHED OR HAVE BEEN CHANGED FOR DOORS, RELIVES, KARDPIARE . DOOR An> RELITE FRAMES OR OTHER STANDARD DETAILS. THEN CONTRACTOR MUST VERIFY MTHH DES1GhV R AND OME'R PRIOR TO CONS T'RJIGTiON. ABBREVIATIONS AGGOUS. ACT. ADJ. APP. APPROX. ARCH. BLK. 13D. BLD6JBL P. B/S GLG GLDG. CLORG GLKG. COL. CONT. GONG. GONST. CONTR. GW.� D. DEPT. DET. DIAG. DiA. DIM. DBL. DWG. D.F. DIFF. D.N. E. EA. ELEV. ELEC. EMER. EXT. EGPT. EXIST. F.I.O FA. F.E. F.E.G. FIN. FORT. F.D. FLR. F.O.I.G. FT. GA. 6ALV. 6L. GJNB. GYP. H. HHGP. WAD. H P. HM. HORZ. HT. HR. HVAG. HJN. IB.G. INGD. INCA_ INFO. INTSUL. INTR. JAN. JT. VICINITY MAP • ACOUSTIC /ACOUSTICAL ACOUSTICAL TILE ADJUST /ADJUSTABLE ABOVE FINISHED FLOOR APPROXIMATELY ARCHITECTURAL BLOCK/BLOCKING BOARD BUILDING BUILDING STANDARD CABINET CEILING CENTER LINE CAULKING COLUMN CONTINUOUS CONCRETE CONSTRUCTION CONTRACTOR GOLD CARPET DEEP DEPARTMENT DETAIL DIAGONAL DIAMETER DIMENSION DOUBLE DRAWING DRINKING FOUNTAIN DIP USSER DOAN EAST EACH ELEVATION (BLDG,)/ ELEVATOR ELECTRICAL EMERGENCY EXTERIOR EQUAL RB. EQUIPMENT R EXISTING RAD. FURNISHED 4 • F. INSTALLED BY OTHER ��' RV ' FIRE ALARM FIRE EXTINGUISHER R.O. Mt FIRE EXTINGUISHER CABINET FINISH S. FIXTURE FLOOR DRAIN SECT. FLOOR SHIT. 51M' FURNISHED BY OTHER INSTALLED BY' CONTRACTOR FOOT OR FEET GAUGE GALVANIZED GLASS /GLAZING /GLAZED GGYPSUM YPSUM WALL BOARD HiGH HANDY GAP HARD WOOD HEAVY DUTY HOLLOW METAL HORIZONTAL HEIGHT HOUR HEATING VENTALATIN6 AIR C.O HOT WATER INTERNATIONAL BUILDING CODE INCANDESCENT INCLUDE INFORMATION INSULATE (DXIN6) INTERIOR JANITOR .MICTION BOX JOINT LAM. LAY. L. LTG. LT. LGJL. MAT. MAX. MFG. MECH. MED. MIN. MISC. MTD. MTh. MW. N. N.1.G. N.T.S. NO. OFF. OFF. O.F.G.I. O.F.O.I. PT. PART. P.P.L. PL. P. LAM. PLY. QT Y. S. SST. STD. STOR. STRUC. SW. TEL. TEMP. TYP. UL. U.P.C. VOL VAR. V.. T. VERT. VP. LAMINATED/LAMINATE LAVATORY LENGTH LIGHTING LIGHT LONG MATERIAL MAXIMUM MANUFACTURER MECHANICAL MEDIUM MINIMUM MINIMUM MISCELLANEOUS MOUNTED METAL MICROWAVE NORTH NOT IN CONTRACT NOT TO SCALE NUMBER OFFICE ON CENTER OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED PANEL LING) PAINT (E1) PARTITION POLISHED PLATE GLASS PLATE PLASTIC LAMINATE PLYWOOD QUARRY TILE QUANTITY RUBBER BASE RISER RANGE RADIUS REFERENCE REQUIRED REVISED/REVISiON ROUGH OPENING ROOM STAIR SECTION SHEET SIMILAR SPECIFICATIONS/ SPECIFIED SOUTH STEEL STAINLESS STEEL STANDARD STORAGE STRUCTURAL SUSPEND/SUSPENDF_D SWITCH TELEPHONE TEMPERED TYFIGAL UNDERWRITER'S LABORATORY UNIVERSAL PLUMBING CODE VOLUME VARIABLE/VARIES VINYL COMPOSITION TILE VERTICAL/VERTICALLY VENEER PLASTIC WOOD BASE WALL COVERING WOOD WEIGHT WIDE MTH WATER HEATER WEIGHT 16300'Christensen Rd 8eettIe, W • ED PROJECT DATA PROJECT ADDRESS: 16.040 CHRISTENSEN RD BUILDING #1 - SUITE i01 TUKINILA, INA 48188 GOVERNING CODE: 2003 I.B.G. (STATE OF WASHINGTON AMENDMENTS) USE ZONE: TUG OCCUPANCY: B CONSTRUCTION TYPE: V -N -FULLY SPRINKLERED ENERGY CODE: 2003 INASHINGTON STATE ENERGY CODE ACCESS CODE: ICC /ANSI AI17.I -2003 PLUMBING CODE: 2003 U.P.G. CONTRACTOR: TO BE DETERMINED PRIOR TO PERMIT ISSUANCE MECHANICAL: BIDDER DESIGN (UNDER SEPARATE PERMIT) ELECTRICAL: BIDDER DESIGN (UNDER SEPARATE PERMIT) SPRINKLER SYSTEM: BIDDER DESIGN (UNDER SEPARATE PERMIT) CONSTRUCT. AREA: SUITE 101 - 3,428 SF LEGAL DESCRIPTION • DRAWING INDEX 71.0 COVER SHEET TI.I EXITING PLANS -THIRD FLOOR Ai.O PARTITION /ELECTRICAL/PHONE/DATA PLAN A2.0 REFLECTED CEILING PLAN 4 CEILING DETAILS I SEPARATE PERM REQUIRED FOR: t ethattical Electrical I‘Minblug llps vroug city of lldcvvlla BUILDING DIVISION Permit No. chin lwles'1 r7. ::oral I; subject to errors and minion& Ilppmval or c :z: uc ioa comments does not atctliorlas Violation c: c7.7 cv'^w ;. %A code cr ordinance. Receipt t4 approved r;;;.:l G :;.J;-d tenth,,, is acfanowledpedt Otte Otyof%daft Mb= 011/12011 REVISIQIIS r!3 ( shall be made to the cc+c - :o :: e:.- hit'„'-,t prior cpprc: - -e e. vr;:I require a • ::- 1.13 L . :..1. �•hllilaR.hhal n� e ve i.:at, review KIi16 caw PARCEL N BLOWS I -16040 ainsnatsei AVE. - 252304- tt0FYl MW 252904 -401b KL116 CaMlY PARG13. Wee BALMS 2 - 16000 CARISTERSDI AVE. - 252304 -4071 KING GOIIIiy PANEL tUEO BUL.V1116 3 - 16300 GFRI51ET15HI AVE. - 252904 4OTb trectLotramicti PARC.11 That portion of tie fit 61111a t Donation Lard Clan *40 and of this southpaw' quarter of to southwst quarter of Section 24, Toswyldp 23 Nash. Rake 4 Bast PO4. and of 6oveni net Lot I h Section 2h' Township 23 North, Rase 4 Bost EH. h King Cours m po tIurlarij descrb d ar talons. comrwwhg at the northeast corner or Parcel 2 of eey or 1%*.db short Plat 9Te -l6- ea record d actor Kh9 Casty Rocordny No. '1406050046; thaw* . tin 64• S2' 24 M root to o pea* of c rvabro; Men..ast.rj 16000 liana Netatorh the arc of a tangent arms to to left, having a reeks of 43600 Net. a control angle of 1T 42• to the erne" point of b•4W*14; an. contr a ary st ir: 146b7 foot the ens or a non - tangent curs, to�the I.lt having a realm of 43500 foot the radius point et .Jich bars north IS• 37 26• .amt thra4, a c.e;Enat a ye of O 00' Or to a pet on sold caw,, Numb. north 06 . 94' S6' asst. 6626 root to a port of c rtrobrs; thence" narthoort rli 6.66 foot otorg the arc of a non -tc gent curve to the eV*. hours a retie of 6200 F.M. the radios port or witch bees saAh 22. G3 O East. thragt a central agi. 0106. 20' 90' to a po** of revere. csrvrogeI a Iiwwe" northeasterly 253 Net along t!e arc of a curv.10 the loft. ha ring a radii* of 2000 foe": ► j en ti a� o central angle of 12 03 to o point of tangency: thence* north 02' I cot 91' a OM fists teem. south 67' 46 .ask 661 feet torte north 02° 37 ant 10677 Net; thawe" north 71' 04' or oast 5122 foot: there.. north 40 east. 6021 root,; theme south 04 00' oast. lam foot; Memo north 40 41• .ost woo Nits there.. south 41 N' east 4054 toot,; thaw. south 24 4T s4' oast 4469 foot; thence" south or 44 5 6• west. 40.43 foot; there. south 24° CO' 55' nest. 4097 root; thence south 34• M' 27 west. 6266 Net there.. south Sr 91' 94' most. 5420 roots Rama south 95• b 26' west. 54.74 foot; hose.. south 94 40' or nook 6962 foot; thence earth 40 24' mat 6634 Net; Memo south 24. or 94• moot, 9'5.76 .t thaw. south 91. 16' 45' most. 1 Nets thence north 7T• 25' 04' cwt 10354 hook there.. north 12 56' oast 2000 Net !Nara north Tr 23 04' rust, 9054 Net to a port of curvalur.; twee sauthnesterly 5246 root along the arc .1 a noa-tangert arta to the right horrh es soda of 320,0 toot„ Me roam port of reach boors north 64 47 54• .wt. Itrough a central angle d 04 34• to a poi: or thane. south 24•4V00' west 4436 feet; thence north 60' l4' 00' meet. rm feet there.* south 64 46' 00' moot. 2461 bate thaw* south 00 14 .yet 630 foot: tense south 84. 46 00' ,wt, 2490 If thence north 00' 14 00' mest,14450 foststhstwo south 04 00" cat. 2430 Net; there.. north 00' 14 00" meet 3400 foot: 6w~ north 16 96' oast 2047 foot to a pout of ameba; Waco southeastorij 4.43 Net along to arc of o iron- tangent curve to Me 11 1. hod 9 o radio or 46650 toot to rwaUS peat of which bears north 16' 05 s5• oast Ihromp a central angle of 00 90 to a pot* on said torso; Now* north 0 2b• oast 91530 fait to the true point of b giv i3 EXCEPT that portion tenet l}ng m*1*h the 90 toot G*y or 5.otte. Pipeline tilt-of-may as re"corde"d u Tag wonder Canty tb. 4106155. (ALSO KNOfrS4 #6 radio d tat 4 G14 of 114tni e a boundary R aayeaeest two. 01-40- PICA gig under ng Gang Recording lb. 0112160540; sad bound: ay en, being o r erblon of City of Media bo i n,. aa)nseswt lb. 01 -I-eL*. recorded ender mOn Gowrb Rocording No. 6102050364. .itch revised Goy or i%krrla Short Plat No. 10 -16-56 r. crd d order gig Cady R.cordkhg No. 7406050046. also recorded hider g County Recording Nos. 'MO60500T1 and 1406050044; T06ETIER NTH a 24 foot bra" ogress. aid uIeRl.s oaa.mert over o portion or Reasod Lots 9 of *aid City of Tib.to boundary the adysbent lb. 61-40 -81./5 lying 12 foot on oath *kb Cl to helafhg described cerise.». mr Gaerwrg at the rwribeest cornier of Paved 9 of sold City of TL ado Short Plat Pb. 76- I6-S6, t .nc..c . h 00' 14' 7 0 oast. 4 11940 foot to the point oT - of this cortertie de.c 011x% taw. north 04 46' Co east 10430 toot to pot* U. cortrarrbg north 64 oast. 2200 r..1 tent* north 21 00' oat. 14336 toot to to point of arvabro; themes 6515 Net dot the arc of a tangent cave to to INt hayin a roc as et :120.00 Net Woo o central angle of 11 to the end of Mb center*. disscrtptlott 430 TOSETIER MN a 25 Not rhgrea *gas*. and unite. .aearw* over a portion of RavYed tots 2 ad 9; sold 6 1 i a dysbneet H. 6t- 40-CLA. ljruj 123 feet on .ath *tds or t e following <b rbed centaiie; Beginning at Pon WI thence, north 00' 14 cwt 2216.00 foot to the and of U . certerlre d.sretptlort ALSO M1H a 24 toot rings. egress cnd Sure* assonant. over a portion el roamed Lot 2 sold boundary the capstones* No. 61- 4O -1R./t Vii j 12 root at oath side of to roper ring described centerline: C,ommencrg d tin. southwest corner of Pace. 1 of said City of mimeo Short Plat eb T0- 16-56, thew* north 00' 14 most 2107 feet to to point or or to a rob* of tile" coder** desoption thin .outea.terlj 43J0 feet along the w e or a non-tangent crew to t* r1c) i n,rrg o roils of 96,00 foot. the roar. poi* of which war *Mb co. M' Oo. .wt Drags aglow of 44 54 ' to o port of ravers. arvnahrv: Memo sou i.a terty 57x04 beet along to a+c of o Ee caw to to left hovi g a radios of 1010.00 foot U vouefi control angle or 2 o 1. 4' int ar�rahrre, donee" soot east.rIJ 234.41 Net along the arc of a torso to I.ft, hoeing a ra no of 2 toot to radius point or .Itch bears north 25' 56' Car ,post through contra te. a contra a of 5' 0'3' 50' to o port of arvetur s thenthence" aw me eat ana or a non-argent this ca th r to e lett herbs a ratios of WOO root the reeve pert of .itch boa nail OW 5r 06• .amt itrovv an th h a cabal might of 9o• 56 to e end or this �� at the VOL 6e** Demotion Land Glom No 40 and of to soul nest quarNr omrrt� 2 9 North, Range 4 Bost ,114. ad of 6ov.mrn'ort Lot I bin Section 25 Township 23 Norte 4 EH. r+ Queer I the of Section 24, T G1 or lb/ado Short Rat No 70- i6-.'6 as recorded under lag Rang. !0'3 c ounty, rios*rgtor coon. portlryAory described a. ►allow.. d ore *ohtl.teet corner d tercet 1 of Records lb. 74060500403 there.. north 00' 14' CO' west 166.41 hate thence south 64' 4T co. *04 .1000 root; tawo north oo• 14.00• ...et 6 rust; thyme earth kr 94 west. 1731 rat; twee swtw a• Or ir east, 66.03 trot teem. oath 42' 04' co' east 7022 foot; tune. south 51 5T 21' cock 102A0 foot tam. eolith 64' 9S 2 .crt. 12150 feet Memo earth 71 07' earl =WO f eet thew. 001411 02' i5' 31' nook 106.17 feet: thence north 61 must. 667 foot; theme south 02' 15' 37' moot OM root to a pot* of csrvaars; tenon soutrwet.rlj 25.113 foot along the arc of a taiga* aria to the rr t hnvrs o s rod of 2000 root Wug/ roi a contra a tw Whn of 72' 00' 23' to a port of revere. acacia*: ine sos.t rly 666 i alomh too ore: of a tangent are. to Our wit toying a sada of 6200 rook WroI a wires or ono 20. 37 to o pelt a+.ald arms; Memo south 06.34' 56' moot„ 6626 foot to o point of ourselves,: therms erm. Earl 14661 foot along Oa arc of a nartang nt curve to oohs hours a radius of 0o Rohl, to rota pelt of .itch bears north 06' 97 25' .ask tutu jh a control ago or 04 q• to a po* on sold eve, t�whr.. oath Id• 52' 26• noot. feet to 0 poi* of curvature's tares .wterrj 4.43 foot along to are of a non - tangent ars* to to right harts a rocas of 46050 Net the roam porgy of ,Arch Wars north 91 26• east trough a control agte of 00' sd' S4' to a port 0 s std curve, them, .oriel 16 55 nest. 2047 feet therm. saAh 00' 14 east. 3400 feet terms north 64' 46' 00' oast 2450 root there.. south 00" 14 oast. 14450 Root, %sane" south 04' 46 00' weak 64.00 foot thaw. south 00' 14 spook 650 Net; therm* south 64' 46 Co ' most. 11530 toot to Port•AS then. north 00' 14' 00' .wet 54600 f.se to eh. per* of bcgbr*ng. t(T that Pollan Mow* Bps Plum the 90 wad ciy or Seattle Pipe** R1y,c- of-mey cm recorded under tag )b 4106'.55., (ALSO Io10wt AS rovis.d Lot 2. City of Walla border: od)st me t No. Oi- 40-nLA, recorded under twig tl�ca+dg ey tb 6a260940; sad boundary she berg a avulsion of city or Rb b a alai: the od)atnert No. 61 -1-aA recorded under 10+g Coady Recordig No 6w Mich ft 2 503dt ch Raed City 9 j of 10 mrt rid I6-6 roco deal odor gig Coins N NO 7406030046 ober under kIi Gae*j Recordheg Nlnbe s 1406050047 ad 1406050044k TO6EIHER lard a 24 foot meow *Tea. and INENto 4140840016 over 0 paean or routed Lot S of Oly of Ibitellia Line Adjustment 10. 0t- 4O.8L4 yhaj 12 toot on each *id. of the tolbwrs desrrbed cat*rlie. lanahemwrg at Poht'A' as desctbed daova thInc4 south 00' i4 00' oast. 7300 foot to the poi* of of cantata deserpltoeh; tare earth 64' 46 00 oast. 4630 foot to Pob rice there.a coe*lwg north 04 46 00' most. 6400 tout to PolorO "r 11tence cort$unig north O4' 46' Co east. 64.00 foot to Pon t north 64 4b Co ' east. 1250 root to the end of this ea*erlie descrgtoer ALSO TO&ET)Et Mill loins totlonrs 75 root ,grass, mgr o* and utslte..o*.ments owe p oreton d r•wb.d Lots 1 era 9 or Obi et iassna ore adJabn.nt No. 6I- 40-BLA ig 125 foot on each aide of the fono.tbig d.sct d cwt rib B.gUv*+g at Pni*`8 thence north 00' 14 meet. 1300 feat to tin. sod or t e, canter** desu�torh; B.gwhbg of PoMt G . tore.. north 00' 14.00" nest 4b30 root to t2. sod of this c hFurw M. doscriptiom Begrr*ng d PC * D . thanes, north co* 14.0o' moot. 226.00 root to the wed of Mb conterOne d.*cr%iton. PSf /}r that Perton of 6ovwrrn.nt Lot t in Setter 29 To., , 2$ North, Range 4 Book Mt, h lag Cost/. rbshhajonl shore portu4arrj described a. follows. Bogtrr*g d the So dvioot corner of fisncc 4 o a iTibioto Shirt not tb. 76-1 -ss ore recorded *War abg Gaudy R.corrbhg lie. 7406090040; tent north 00' t4' 00" mask 2)0.00 foot to a �* of aruat rdi: tam. nortdNj 104.12 rose alas tr am of a are. to to lett. lavrhg a roam of 40.00 tout, the radio poi* of welch bears north 00' 14 Co" west Strove) a control ago of moo 00' 00' to per* of suer.. arvdur s thence snort er% red long Ow arc or a taiga' aeve to t o rig*, haying a rafts of 4000 foot Droop a cad age of 60' OO' 00" toe pot* of targ.rc: them east e, north 00' 14'00' ct 12151 roe them. north 64' 4V Co ' cost 15.40 feet: theeme north 00' 14 coot 050 ravt: t enc. north &I' 46 co. oast 40 fief; thence, north co. i4 00' west 030 foot these. north 64 46 co. east 2461 foot therme" south 60' 14 00" east 1754 root to Pont thence ,north 24' 46' 00' oast 4436 Not to a poi* of arvah rc, Wino* nortlwy 92246 beet along to any of a tangent arvr to the ft Thefts a racks of 92000 foot trams a antra tad ahgie of 04' 23 i4' to e pelt on saki arve; Name south 71' 25 04' oast 9034 root tfheewsp south 12' 5C 56' most 2300 hoot therm. earth -rr 25 oast 10334 foot: thence south 31 W 46 .rest ND4 feeq term. lath 34 52' most 6034 fist, theme south 90' 51' 21' meet 61.16 toot` thymsp south IV 16 nest 5344 root: Weer. oath d• 57' 27• mat 5162 foot; tams eolith 13 401 40' most 5439 foot therms *oath Co " 96 oast 6254 teat thence oath 00' 143' 53• most 4121 feet thaw• south 07 i6• east 9377 fasts thence south kV 27 46' east 5637 feet thong. south 2r mil- east 324 fo tc th.nc0 north 64' 4R Co omit 54834 fuse to Br pot* of beginning ems 1010V61 AS revised Lot 9. of CXy of fur rla boundary the adysbrw* No 61.4043LA as r cord d odor gig County Recording No. 6112160540, berg o ~Mon of boundary ire ady*tme nt No. 61-1-BLA as accreted Oder Mg Gary R.eorrdtig i 6102050964 ranch reared Gig or Walks Short Prot Pia 16- 16-50, recordist under Id1g C.ow*hj Rocorang No. 74O6050046, also recorded nosier gig Carty Rvcordrg t b s . 7406050041 ad 7 4 0 6 C 0 0 0 4 1 ) T T 6 E n E R resit a 2 4 r o o t Impose, .g s o . ad totals sasanee* over o portion or rovl..d tat 1 of City of Trade Beadier: Ise #wine,* No. 611-4043LN. 1 9 12 toot c WWI te M w u" t h vlg a radius s of 320 feet t r 4i a c. * P of s N •44 io o�pob on add s& • t w w. ar southh T � Soot 9 m of w .m of M*. cent rtw bals ► tin. a+G or a tango* SITE PLAN CITY PARS IIII 11{ 11111111111{ {11{Ij �I I l I I I l l l I I l I I III.I.I.I l I l I i i 1 I iIIIiTIiIIIII1111111111I1i1 /ll W1Il illiiii iiiii it LIlllj f 0i1II11IIIIt (IIIIitflI111iTTTTU IIIIIIIIIIIIJIiIIIJJIIIIIIIIIII cFiDIS; rIc % 0:7Ae CONTRACT THIS SUITE-101 U i 1IIIIUIIHIUIUUEIIIHIIIUf I f IlllliiltIIiifIlllillllllltlilll II!IIIIiIIII: U IIiIII{I{?IIII!(. fl hIIIIl€I.1.I4lll l i1� hill .IIIIIIIJ 111{1 tillllt {fIIIII',I;I RECEIVED CITY OFTiJMLA 11AP 2 2007 PERMIT MITER is C o plonks inferiors orclhifeciere DESIG 22002 - 64th Avenue W., Suite 2C Mountlake Terrace, WA 98043 T: 425- 670 -6706 F: 425-774-8219 REGISTRATION PROJECT NAME SPEC. OFFICE RIVERVIEW PLAZA TENANT IMPROVEMENT BUILDING 1 - FLOOR 1 SUITE 101 16040 CHRISTENSEN ROAD TUKWILA, WASHINGTON 98188 RE IEWED FOR I COD COMPLIANCE 1t rsrtelWWCtl 'I - 4 ZOO / 1 a J 01 Tukwila BUILD IN DIVISION DESIGN TEAK PROJECT NO.: 07.042 PRINCIPAL: CK DRAWN BY: KMWH CHECKED BY: \e'e PAIL �r MTh CF W • ISSUED/REVISIONS 3 -2647 ISSUED FOR PERMIT P oIEQ COIISIJUAJUS SHEET URI COVER SHEET SKIT NOS. Doi T1.0 NE1J s • EXITING PLAN -FIRST FLOOR SCALE :1A6' =1 CONTRACT THIS SUITE • • EXITING ANALYSIS: 3,42' S.F / 100 = 34.2 OR 35 OCCUPANT LOAD 35 0.L. < 50 = I EXIT REQUIRED COMMON PATH OF EGRESS TRAVEL: 2003 IBC SECTION 1013.3, EXCEPTION 1 - TRAVEL PATHS < 100' W/ SPRINKLERS ALL OF THE TRAVEL PATHS ARE < 100' AND THE BUILDING IS FULLY SPRINKLERED REVjEj4EO FOR CODE COi•W4'LI�NCE 1 I C TU<' I t� 1 C►�Y I1 •SSG BUI1tl1 G MOW CITYOFTuuIK11A MAR ? f, 2Q01 r : • C o plenaiai inferiors •rtiiletlere DESIG 22002 - 64th Avenue W., Suite 2C Mountlake Terrace, WA 98043 T: 425 - 670 -6706 F: 425 - 774 -8219 REGISTRATION PROJECT NAME DESIGN TERN PROJECT NO.: 07.042 PRINCIPAL: CK DRAWN BY: KMINH CHECKED BY: CK SWEET NQ PROJECT EOITMNI'S SIIM TITLE ©MNG PLAN C o : ., • = IF PAIR. 1 1 11 1 8TA1E OF W = • • i SPEC. OFFICE RIVERVIEW PLAZA TENANT IMPROVEMENT BUILDING 1 - FLOOR 1 SUITE 101 16040 CHRISTENSEN ROAD TUKWILA, WASHINGTON 98188 ISSIED/REY81011S 3 -26-07 ISSUED FOR PERMIT T1i. NEIL • 6 DOOR SCHEDULE L t RATED !117TH HEIGHT _ TYPE F MAT. _ FINISH HARDNARE REMAWS 101 20 MIL 3'-O' BLS B B15 B15 IH WO - 3-0' B5 A Bl5 BY5 I11-2 DOOR TYPES HARDWARE TYPES - VERIFY W/ OWNER WS WIJD 20 SS 92/D MIN RAND SOLD GORE � - 1BZNir L3TiTRV. LVT. NT.) CLOSET. 1i'W2 - IOWA• I1TIJL101L LATiCINb GORE , ... DOOR NOM L ALL DOOR AND DOORSIAY5 STALL GODLY NM iCC/ANS AIi1J -20103 404 CODES 2. MAKE = DAMS STAIOARV 3 CONTRACTOR 10 RB>6E NV RELOCATE 0051115 DOORS ND IMAM MOE POSSIBLE 4_ ALL DOORS TO E BEEPED NTH LEVER: nl°E LATCRI* ituesNRE atom APPROVED IWDIG P AGf.E56ELE CON 76tRATION PER ICCIARS 40426 AND 4042.1. 5. ALL DOORS TO TIE OPElABZ E RICH 11E OWE imam m A IEY OR Mr *ECM 121216716E OR BEFORE 6. E051I45 DOORS TOR NK - 1 tf1E55HO .p5 AT POMMY MOLL OE VT MAX *Hew RR KG/A/15/ AFT! -2009 SECTION 4042.4. 6 IRE DOORS WU. MOE 111 Mt OPDIitir FORCE iMLOWELE BY THE APPROPRIATE ADMINS1RATIVE NI NINNY- FIR ICC/A1451 NRP -2203 40428 4. VB1FY PITH 1130/110JAD115 MOSS t INCH DOIOM HU. IMO L0025 I �• 1 t 1 ) f / v © - • • 0 DEMOLITION NOTES NOTE: RE-USE N.I. DOSTi146 OIPIGE DODRS *ERE VO&OLmON OCCURS, ALL REMAINING MAE.LS ARE TO BE PATCHED, SANDED SMOOTH NV PREPARED FOR F11511146 AS PLOWED. R1340VE EKI5TIN6 FLOOR FUSES PATCH NV PREPARE FLOORS AS REWIRED FOR SMOOTIT, LEVEL FINS. ALL E U91 AU. TO OE REYOVED !TAUS ARE TO EE PATCHED, 5N 9MOOiH NV PREPARED FOR NM MIES AS NECNI R MERE i M PARTITION I.WTS E051115 FURRED RE-D G U 4 OR GORE YW.L, REMOVE CORM BEAD, ALIGN, TAPE MV SPACKLE t 1 PARTITION TO 00SIIN6 WPM BOARD. ALL CON51RUGucN TO R&w i AND AFFECTED BY DEict.Ifloi SHALL OE PATCHED AND SPACKLEO AND BE PROPERLY 1E145ERED AND ALTERED SO AS TO LEAVE NO EVIDENCE OF PATCHD CR REPAIRS. EMUS aEG1RIGAL AID MIME OUTLETS LOCATED ON DEVLLSIED HAU S ME TO OE SUNNED INCLJJORi9 COWUT NV N RQb BACK TO J41GTbw BOX LOCATIONS ARE TO BE PATGIED MV WAND TO BE rum NTH ADJACENT MALL SIRFAGE FIVE PLUMING FIXTURES AMENS 1434003) OR Y*ERE EXPOSED RUMt81f6 PIPES OGGI R. GAP MS EOM FINISHED SURFACES PATCH AND REPAIR AS REG1ARED. ALL EXIST** CONSTRUCTION MERE INDiOAT) I UUIN5 ELECTRICAL, TB.EPHOIE, RIJMBW5 AND hECHARM DEVICE'S NOT OTHER/15E INDICAiED ON 1IESE COi 51111VIGH ORAY1N6S SHALL EE REMOVED IN A CAREFU_ MtA IER 50 AS NOT TO P»t'6E NAM* GOIUTRUGTION. PARTITION NOTES CONTRACTOR TO VERIFY ALL Ont151045. N.I. DISCREPNICES MIST BE EROI$HT TO TIE II44DIATE ATiENTION Cr THE ARGl1TEGT FOR DIR6GTIOR AU. PARTITiC , UNLESS OTIERM E NOTED, SHALL BE C0W1111iG1ED NTH METH. 511105 AT 24' OL. P0II 518' TYPE 9P 6W914 WALLBOARD EACH SIDE. THERE ,MALL EE NO EXPOSED PIPE, CONDUIT, DUCTS, VENiS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR RIMED AND FiN51Efl. MESS OTHSTASE 1101W AS EXPOSED C0115111LCilal ON ORAPI1465. OFFSET 51105, MERE ROMPED, 50 THAT FNSIED PARTITION SURFACE PILL BE RDA *LESS 5 0813015E /VIED. PROVIDE FURRINS AT DUSTING PARTiTLON5 AS REC1ARED TO INSTALL ELECTRiCAL 111345 AS INDICATED OH HE ORANIN65. DOOR MV CASED O'OIN66 NUM LOCATION D 1C% ARE TO BE SIX INC/ES FROM FACE AT HNSE SIDE OF DOOR TO ADJACENT PARTITIONS. ALL EXIT DOORS SIWL BE OPERAELE FROM TI E INSIDE PITHOUr USE OF KEY OR ANY ma& tQIDY+LE06E OR EFFORT. PROVIDE 9OT METAL PEI/FORCING Or HORIZONTALLY MOWED STRIP OF 20 GA. 6ALYN12W SLEET METAL) 1i PARTITiOIS FOR INSTALLATION OF WAIL BRIE CABINET ?VW MV PN11.IN6 MERE INDICATED ON DRMIN6514GLWIN6 ALL OMElt PROVIDED ITDS. CONTRACTOR TO VEYtFY 01t4 31510115 FOR ALL P111113145 PARiITlC 6 CONTRACTOR TO PROVIDE SHOP ORA"T"ES FOR DESI6I6t AND i 31ANr APPROVAL PRIOR TO MANJFAGIIME OF ANY GABIIE f PIORIS, M1.L MORK, AND ANY OMER SPECIAL 1045 N6 mom SHOP FATED WORK. PARTITION LEGEND = -_ = == DEdOU110N BMUS PARTmGIl 10 MAK 815 1EPIA1ir PARTITION - BY5 METAL S1U05. 24'OL. 11111 Sir TYPE hC 6PB al 00TH 51015 FROM FLOOR TO IIVERSIDE OF tuts mutes. 3 C 815 2 x RU. IE1611r 45 ML RATED SAFETY 6L A 6 RELTIE 1f 015 RATED FRAME A56EIELY. 0/5 2'-0'' x FLU. IEI6HT SAFETY GLASS Pa11E B 015 FRAME KEY NOTES I. RO40VE DOOR AND FRAM N 1.10 MATCH OUSTING COISTRUGTiOIR 2. REMOVE EMIRS PAiR CF MIRY DOORS. 3. REMOVE 1)451815 RIRRM6 TO 017 Pt1fa0NlS ELECTRICAL NOTES- VERIFY FINAL LOCATIONS W/ TENANT ALL MALL MINTED THERM AND aE TRIGAL OUREIS TO OE IISTA ED ib' ABOVE FLOOR 111E56 OPER TEE MEM PLUMY WRE MIL LOGATIOIK SWILL. BE VERBS) NTH TE5161Eft PRIOR 10 DRELN6r ALL MEW CORE DRILLS 9W.I. BE FLU66W MV CAPPED AS MIMED TO MAINTAIN BOOR FIRE RATING►_ ALL 1H.EPHOIE AND cC RfuR FIRES SHALL BE RILED EN TERMS GOfIRAGTOR RIESS O IERME PVJED i I G1RICAL. CONTRACTOR SHALL PRNIDE PILL MIRES AND BO/ES AT EACH LOCATION. ELECTRICAL LEGEND PWL mum MID( R6GE IL OUTLET MAU Fumy GUADRAPLE)C R arrAGLE OUTLET a MALL MOU(RD COMBINATION 1110410IE AiD DATA OUTLET E ERN* 6F1 6R21D FAULT INIEPRIPTBE I c 1IRAGTOR TO MEE NV /OR RB.CCA1E D051RS ELECTRICAL /113131VIE AIILET5 MERE PCSS LE ALL 00511"6 B.6G1mCAL / TELEfilOIE OUTLETS NOT SHORN ARE TO TOW& USE MIDIS STNVARD BEG1R M. R CRlItES IHR USICOUr U1LE.,6 OT ERY/SSE MED. NO YIORIC 1115 SA E DEMOLITION /PARTITION PLAN SGALE:1/8'= I' -0' NA/ SCALE: I/W=1 AA AA OPL]I OFFICE a0 ELECTRICAL /PHONE /DATA PLAN p, AAA M n A A . - 4a A A 4 44 r E EIT efEr EXIST. MICE E 4 flC6T. WOW II I®2� 4 E Y A -Cr WOW FR I I II a. E 1201 Y RECEPTION D FOR REV lEnE 1Lti�� CODE CO3 PLIST \`',lr rin %" =n .,��; — . ff Tot ola gU iL ' G 1)1W4T(YN FIECENED CITYOFTmovitA M AR l C ON EL L pleasing iil+riers 'ransom 22002 - 64th Avenue W., Suite 2C Mountlake Terrace, WA 98043 T: 425- 670 -6706 F: 425 -774 -8219 REGISTRATION PROJECT NAHE SPEC. OFFICE RIVERVIEW PLAZA TENANT IMPROVEMENT BUILDING 1 - FLOOR 1 SUITE 101 16040 CHRISTENSEN ROAD TUKWILA, WASHINGTON DESIGN JEAN PROJECT NO.: 07.042 PRINCIPAL: CK DRAWN BY: KMWH CHECKED BY: CK NSUEDREVWONS 346 -07 ISSUED FOR PERMIT PROJER WE RTAIIJS BET TIJII( DEMOLITION Si PARTITION PLAN A1.0 i a • NOTES SPLAYED SEISMIC BRACING WIRE ATTACHMENT 516' DRILL -Q1 EXPANSION ANUIOR MINIHII I I STEEL STRAP I' WOE X 2' LONG X 12 6A6E 3 1114 a SFLrn SB EG /WE VERTICAL HANGER WIRE ATTACHMENT ATTACHMENTS SCALE: N.T.S. SCALE: N.T.S. STRUCTURAL GONGREIE SEISMIC SEPARATION NOTES: I. FOR MR* AREAS EXfAID619 2, 00 50 FT, A 5EISFIG SEPARATION JONT OR FU..MIGHT HALT. PARTITION THAT BREAKS THE CE LN6 SHAH BE PROVE ULE56 ANALYSES ARE FE RFOFTwD OF TIE GEQ.RIS5 BRAGR SYSTEM, CLOSURE MELE5 A V PB+ETRATlONS TO PROVIDE 9FFTCIBif GLDIRANGE. 2. THE LAYOUT MV LOCATION OF THE SEISM SEPARATION JOINT SHALL BE PER TIRE DES1G OF RECORD AND NOTED a4 TIE KANS. F A 565/46 SEPARATION JOINT 15 MI. BY 1HE DESIGNEES THE DES16113i MAY IPSE TIE MOOG JOINT DETAILED ABOVE OR A PROPRIETARY JOINT. THE AMOUNT CF IREE: MOVEI.Uft i 6AP DEMO) SHALL BE PER TIE D1516IEt OP RECORD. SEISMIC SEPARATION JOINT w • SPLAY FIRES ARE TO BE MIL 4-12 6A. MRS ATrACIE7 TO THE MAN MAK FOES ARE ARRAYED *TO' FROM EACH ODE( I AT MI ANGLE NOT EXGffDQI& 45' FROM TIE PLATE OF TIE CIA HAMS R /WES SHALL BE 12 6A I 4' OC OR TO 6A 15' MAMMAL $ L ENDS Cr EA MAIN OR co RSSS TEE 14 /ST BE SMELTED nnMN IY CF EA. /TAU_ OPTIONAL LATERAL. BRAGQ* SHALL BE 12' BERN (6' WON 1I/115-51M CHART FOR 5IZE5 ATV VERIFY LOrrAL. CODE FM LAT. FORCE BRACAI6 4 Ell 12 6A. MIRE SEC1RED TO RA 1 RIMER NITiRI 1-0' CF CRO56 1I AND SKATED 90" PROM EA. on • MO' OC. BOTH VIREGU 6 Tai/FIRST R081T ono f-O' FROM FA MALL Was euw:- DeAvr oven CROSS 113E L WALL SY51D4 N PGCORDARCE 1"V 21003 IK MEMO-635 NV G6% Awe 1.02 4 COCA 2. 1A1 IMAMS F511QARH0 FCR a& )1000 5F AND MN PUMPED FOR GL . c 1000 PROMO,11E1r ARE 5U11ROUf7ED BY 4 MALLS AND BRACED 1O SiRIV1ilE. Roue c 12' PO TiO1r IEED LATERAL MAGUS. 60066 TEES MALL BE CAPABLE OF GAIRRVPFs fl DED6N LOAD MOM MEMOS DEFLECT= EQW. TO IFIGOOF ITS SPNL 3. LATERAL FORCES BRACES 91A11.0 E 1? OG. MW AND OBSI i 110 RRTHER THAI 6' FOOD I was 4. USW MOMS c V LEG SHALL NAVE 1 1261E WISER. LENT MU E5 ) TO LEIHs ATV c 56 IES SHALL HAVE 212 6,01 PORES ATTAOEP ATOMSS/a CORMS OF THE user ROUE TO THE swam ABOVE FUMES *6 LEfa SHALL I£ aFFCRIED DIRECTLY FF10II THE 51TRiK.111E. GEWL SUSPENDED CEILING BRACING SCALE: N.T.S. NOTES: 2' MIN. I. THESE RGGOMUVATi01'S ARE MENDED FOR 5U5PB87ED GEN.116611GLUPINS 6RID, PMLL OR TEE, LIGHT FI URES AND AIR MINAS NEI6I1116 NO MGM THAN 4.05. PER SQUARE FOOT. 2 . ALL /TIRE TIES ARE TO BE THREE WES. TYE.VE GAGE HAN6ER WRE SPACED 4 FOOT CH a. CHANGES IN GEILI 15 PLANES POLL REGIME POSITIVE DRAMS. LATERAL FORCE BRACING SCALE: N.T.S. RIM V6 6 MAX 3/4' Mk AT UNAITAGIE7 SFREAVER BAR CR EQUAL TO I®' FERNIER CCM CWER 5 FROM SPREADING APART NOTES: I. MALL MOLMN6S (PBRI IE R GLOBE AI6LES,�) ARE MUM TO HAVE A NORIZONATAL FLANGE 2 *VIES 1110E, 1114e6 ALTERNATE METHODS ARE APPROVED PRIOR TO I SiTALLATION BY THE LOCAL BULDW6 CWT. CM BV OF THE GEM GRID SHALL BE ATTACHED TO THE MALL 1VLDQS, TIE OTI R END SWVI HAVE A 3/4' CLEARANCE FROM THE W1.L AND FREE TO EWE 2. PE 6R10 SHALL BE ATTAGI D AT DV ADJACENT MALLS POP RIVETS OR APPROVED M ENO S 3 MERE SHALL BE A MI MIII4 30/4' CLEARANCE FROM DE DV OF TIE 6RV SY51BI AT IM- A7UGIE2MALLS. 4. SPREADER (SPAGL3R) BARS OR OTHER MEATUS APPROVED BY LOCAL. EIUI DQI6 Di3'ARTMENf SHALL BE USED TO PREVENT THE DVS OF TIE MAIN BEAMS AT PERIMETER MALLS FROM SPREAD1I6 OPET4 DURAI6 A 5E15MMG EVENT. PERIMETER NWRES SIPLL NOT BE IN LE1 OF SPREADER BARS 5. ?WE 1YI1 IS AGGB'fABLE M.1LRiLA VE TO SPREADER BARS. 6. WEAVER BM AREN'T RE G. F A 9O DE6R>3: 11TER56 11N5 CROW OR MAIN IS Ih11I N 6 MIES OF THE METER MALL SPREADER BAR & WALL MOLDING SCALE: N.T.S. HANGER (SUSPENSION) WIRES SCALE: N.T.S. NOTES: I. 16W6Ht AND PEIRIETER FIRES MOST EE R1I113 MINN 1 116 UNLESS COIII1Ht SLOPQirs /IRIS ARE PROVMD137 2. NWiSER IDRLS SKILL 1E 12 GAGE AND SPACED 4 FEET 011 G3(T13t OR 10 6A6E WAGED 5 FEET CR GEM. 3 ANY CCHWTIow DEVICE AT THE WORMS casnwonat SHALL BE WANE OF GAMINS NOT MSS SON 100 PLOWS. 4. FOR E56E3/11AL FAIA_.M MISER TIRE CO W:OT10N5 MST BE CAPAL'AE OF CARRY* 200 PONDS AND DRAMS (SINAY) OWES 91011 0E CAPABLE OF CARRYN6 440 Min 5NOT -11 ATICIiONS III CONCRETE ARE NOT PERMED FOR DRAMS MIRES. D. CRAMS MI39W.L iE ATf?GHID 10 11E 6160 NV TO TIE 51111.GR E 11 WI A PINNEI3R TEAT THEY CAM SUPFDRT A DE S16NI LOAD CF 11211136 TWA 200 FUNDS OR TIE AGTIIA _ ESI614 LOAD, NTH A SAFETY FACTOR OF 2, ISIGIEVER 5 GREATER 6. PGNf7Et DRIVEN MISERS FE APPROVED FOR APPFIOPIVAIE LOADfi6. t TIMONUL DVS OF EA01 MARE OEM ARV CE1065 TIE 1W BE SFPIORIFD MIN 6 saes Cr EAGN Wel NDI A P98EETet NINE. • ■ I 381 •. TANDEM FL OLM MAY UTILIZE CCMI'tZ4 NQRES. . o OWE SEISMIC BRACING PERSPECTIVE CEILING GRID GENERAL NOTES ca_Rb BRAUN% SEE PETAL Il 1115 SIM 121=1 SCALE: 1/6"= 1' -0• Gamut SLOPE/SPLAYED 51354G BRAGRIS Y E ATTACIFE T, SEE ATTACMENT PETALS THIS star ELECTRICAL FIXTURE NOTES: I_ L16HT F1X1UR S 1EI6HIHI6 LE% PLAN 10 ?CAWS S MAIL HAVE ONE 12 GAGE HANGER N CO MOT D FROM MIME TO TIE STRUM ME ABOVE 1115 HIRE MAY BE SLACK. 2. UGNr FIXTURES 1136IIN6 MORE THAN 10 POUNDS AND L.156 DIM 561.05 SHAM HAVE T110 6A6E HIRES ATTAOW AT OPPO6D b CORMS OF TIE LIGHT FIXUPRE TO THE 51111G1%URE A80VE THESE MI5 HAY BE SLACK. a. User MIRES 1E16111115 KW THAN 56 L. SHALL BE 9FPIORTED DIRECTLY FROM TIE STIVGTIQtE ABOVE 4 - FDVANr MOUTHED FIXTURES SHALL BE DMEGTLY SI'PGRTED FROM TIE STRUMMER ABOVE L OS A 4 6A6E 1fIE OR AN APPROVED ALTERNATE 5IFFPORT max 1116 TIE GEUi6 SEF1315I01E FOR D4RGGT SWORE MECHANICAL SERVICES NOTES: I_ T@3TLNAIS CR SERVICES Ng6111E6 2016,, nor NOT MORE THAN 56!85. MUST NAVE T11012 6AME 1f1E.SS COMEiCTNS TIHBI TO TIE GELt49 515181 HANSER5 OR THE STRUCTURE ABOVE THESE /WES MAY BE SLACK 2. 1804IIAL5 OR SERVICES /MI NS MOLE TWA 56LBf . It6T BE MOEFOIN LILY swam OMIEGILY FRCW TIE STRUCTURE ABOVE 1115E PORT'S MST EE TAHR. SPRINKLER NOTES: 1. FOR CRESS rum wisp IMAMS, Et MEAD FE ETRATi0H6 99.1. WE A 2' OVERSIZE RMI6, sum OR Awns 1NO061/ TIE GE IUN6 TLE TO ALLOW IRE )VV@f51T OF AL LEAST r N ALL HORIF,ONAL DFREGTi015. FUME LEAD DE516N THAT CM ACCCMItiFAIITE r FRS I+IOV@tfir MALL BE PERMITTED AS AN ALTI ME. • • I C wi REFLECTED CEILING PLAN LIGHTING NOTES CftU 5 IEH6HT5 ARE FROM SLAB TO MOW 6111.8 5 LIGHTING LEGEND (2) E R 0 LIGHTING CALCULATIONS EXISTNS a 2 x 4 FiVCRESCBIT LP6Nf FlXIURE TO RBAN E)G5TQI6 O 5 RuOR1 S�GENT DOPwSIHT TO R@(AM 1U1I MED EXIT 516H - DIRECTION CF ARGON! EI�'S 5NSLE SUCH 115 PD. ER SSTCH INS 3-MAY SNITCH INDICATES COMITY D051116 TO REMAIN RH.OGITE DOMTNS FIXTURE CONTRACTOR SHALL PROVIDE SEEM BRAGN6 • ALL RELOCATED USHf BOWES. CONTRACTOR SHALL OBTAIN APFRI NAL FROM DESI6HBt OF ALL 1IERMOSTAT LOGATICI& PROVIDE FIRE PAMPERS AT ALL SUPPLY NV RE1112N AIR CUTLETS, I ETS. 17»5 PBETRA1146 FME RATED ASSEM _ES, BMLOSAES, PAILS, FLOORS, OR SURFACES, AV AS BY rwE V Mfl 3lf, F APFUCAELE ALL REGVIRED EXIT 51615 SHALL HAVE LETTERS 51X ROES HIGH MNMIM AHD SHALL CONFORM NTH ALL APPLICABLE CODES. LIGHT SVITCHE.S SHALL EE INSTALLED AT 448' APP. MI1131PLE SMTGIE3 51 AD BE CAMEO TO6Ef EIt UNLESS 0111 SE SFECIFED CONTRACTOR SHALL F RO flVE 134at6D Y U6E1TUN6, STROBE 1.I61I15, M/010- VISIPAL N.ARI1 TO MEET ALL APPUGABLF CODES CONTRACTOR TO VERIFY ALL 5N/TGH LOGAT10N5 PIM TWAT PRIOR TO QHSTALLATIOIL NICER OF SNITGIES FOR OPEN AREA 5 BM7DI=R DIvl61&L 9ITGISS IVIGAMB2 ON DRAMS FOR OPEN AREA ARE FOR PERREIVE OILY. CONTRACTOR SHALL PROVIDE LAMPS 1V RAZED F USSIN65 /TEM i MIRES COME 11 DWECT CONTACT NTH 'SLAT= LATiON CR PROVIDE ENO TENTHS KR LOCAL CODE STS: REVIEWED FOR =PE; A E CODE l.Gl::r ,.�. fi fl%',S: rs e NOTE: CONTRACTOR TO ME NV I OR RELOCATE OCATE D051ii6 UGH! MUMS NV 9STCl15 MERE PI0661BLE CONTRACTOR TO ReSNffcH / REGIRCU1T WIT SIMMS NV LIG FiXTT11E5 AS N3 ALL DQSTRK U6HT MIMES / SNTCHES NOT 61216 ARE TO F134•t ALL D051I L16Iff MIMES TO RBiAMM IMTIRI 16Wir SPACE, IV PIOOPOSLD CHAISE N 8et6Y IBA6E. 1 -- City Of Tuk .i!a BUILDING MitsTf N • o' CAVOF TUKWki � z " �f - • 2 ' ; 2V J' PEWIT C :zr. Co. N EIL pleasing ieleriers ercLileclPre DESIG 22002 - 64th Avenue W., Suite 2C Mountlake Terrace, WA 98043 T: 425- 670 -6706 F: 425- 774 -8219 REGISTRATION PROJECT NAME SPEC. OFFICE RIVERVIEW PLAZA TENANT IMPROVEMENT BUILDING 1 - FLOOR 1 SUITE 101 16040 CHRISTENSEN ROAD TUKWILA, WASHINGTON DESIGN JEAN PROJECT NO.: 07. 042 PRINCIPAL: ac DRAWN BY: KMWH CHECKED BY: GK ISSIJED/REWSIONS 3 -26-07 ISSUED FOR PERMIT SHEET 111E REFLECTED CEILING PLAN+ AND DETAILS SHEET NO. PROJE CO NSULTANTS A2.0 - 1