HomeMy WebLinkAboutPermit D07-213 - SPRINT - EMERGENCY GENERATORSPRINT 11030 EAST MARGINAL WY S D07.213 CityLf Tukwila Parcel No.: 0323049057 Address: 11030 EAST MARGINAL WY S TUKW Suite No: Tenant: Name: SPRINT Address: 11030 EAST MARGINAL WY S , TUKWILA WA Owner: Name: SEA POLICE ATHLETIC ASSN IN Address: 11030 E MARGINAL WAYS , SEATTLE WA 98168 Phone: Contact Person: Name: MATT ENGLESBY Address: 568 1 AV S, #650 , SEATTLE WA 98103 Phone: 206 310 -2290 Contractor: Name: EAGLE COMMUNICATION SERVICES Address: 1026 26 AV NW STE C , GIG HARBOR WA Phone: Contractor License No: EAGLECS972QL doc: IBC-10 /06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D07 -213 Issue Date: 07/09/2007 Permit Expires On: 01/05/2008 Expiration Date: 06/26/2009 DESCRIPTION OF WORK: INSTALL AN EMERGENCY GENERATOR INSIDE AN EXISTING COMMUNICATION FACILITY COMPOUND Value of Construction: $2,000.00 Fees Collected: $145.91 Type of Fire Protection: NONE International Building Code Edition: 2003 Type of Construction: lIB Occupancy per IBC: 007 -213 Printed: 07 -09 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N The granting of this permit does construction or the perfo doc: IBC-10 /06 City a,,../Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D07 -213 Issue Date: 07/09/2007 Permit Expires On: 01/05/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: – 7 -4 1 0 7 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether s r ecified herein or not. give authority to violate or - - . e provisions of any other state or local laws regulating am authorized to si tain this development permit. Date: 7' / • e Print Name: / R o- 41 v i e 5 This P Li not shall become null and void if the work not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -213 Printed: 07 -09 -2007 Parcel No.: 0323049057 Address: 11030 EAST MARGINAL WY S TUKW Suite No: Tenant: SPRINT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D07 -213 Status: ISSUED Applied Date: 06/12/2007 Issue Date: 07/09/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: Fuel tank must be located a minimum of 5 ft. from the building and 5 ft. from the property line per NFPA 30, Table doc: Cond -10/06 D07 -213 Printed: 07 -09 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 4.3.2.1.1(b). 16: A separate flammable liquid tank installation permit is required to be obtained from the Tukwila Fire Dept. located at 444 Andover Park East, Tukwila, WA 98188 206 - 575 -4407. 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IF'C 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** D07 -213 Printed: 07 -09 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond-10/06 Date: 7 ?,07 D07 -213 Printed: 07 -09 -2007 SITE LOCATION ( r L King Co Assessor's Tax No.: 6 3Z; 6 Li 905 7 Site Address: { I 30 C�itST �a�Q .ro I / s. Suite Number: Floor: New Tenant: ❑ Yes p..No rt Tenant Name: . _ - Property Owners Name: A . r- i e'„-. % o.. ,r f " yl� r Mailing Address: in r p S. ��r,�T : a Wet I �D rn City CONTACT PERSON - who do we contact when your permit is ready to be issued Name: M A' f L rIsI v < Lv Day Telephone• 206- 3(o , 2 2 yip Mailing Address: ( 5�8 l�A ro S- 6 Sa S� 7 r 111/ gR /a 3 // / J Pity State Zip E -Mail Address: m ( k/CL .6 Fax Number: -2 -c , 6 ' ?G3 -S5 GENERAL CONTRACTOR INF - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: G a5 ( e Conlm t ti : G a S Mailing Address: 1°2,6 Ave- AA./ C E: (o e r 14/A ig 33 S City State Zip Contact Person: . Po r -/ C.,s tr. Day Telephone: 1 5 3 " e -S 8 — 9-6 l f E -Mail Address: mod./ ec S r t- . er f --1 S. Goh+ Fax Number: Z S3 - SSA - /2t2 / Contractor Registration Number: P A-& C'R 9 7 2( L Expiration Date: 6/16/07 I ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: ge-t , c-- C'e Mailing Address: 56 / A - I S g S Contact Person: AA of Ere i es S • E-Mail Address: Mee, CiP `✓a" . ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: J) A Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\ApplicaiionsTonns- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9-2006 bh CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tukwila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For oft ice use only) A4 A. Zip City State Zip Day Telephone: 2-i • 3/0° 22-7 6 Fax Number: • 9153 - .0573 Page 1 of 6 BUILDING PERMIT INFORMATION = 206 -431 -3670 Valuation of Project (contractor's bid price): $ 2_ •Db Existing Building Valuation: $ /86) Oob Scope of Work (please provide detailed information): . h r pre eynerse, r s: f--�• / Will there be new rack storage? ❑ Yes k. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below l" Floor 2°tl Floor:' 3'd Floor Floors Basement Accessory Structure* -' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Interior Remodel jJk Addition to Existing Structure NA Type of Construction per IBC /1 -13 Type of Occupancy per IBC Uhr,C PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Q:Mpplications\Fams- Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 m Handicap: Number of Parking Stalls Provided: Standard: Compact Will there be a change in use? ❑ Yes l< No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm )2( None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Saf ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate PUBLIC WORKS PERMIT INFORMATION- 206 -433 -0179 Scope of Work (please provide detailed information): r' I 5 Ort era Tdr 4 <2.- i+ ���.-1 io /+ - , /13 c..jowlmGYi. t . .D s Taco I i C'aw l��c' - Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided ❑ ... ValVue ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Stone Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection ,f Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public _ Private _ ❑ ...Water Main Extension Public Private CE I FINANNFO RMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Mailing Address: City State Zip Day Telephone: City State Zip \Pa QMpplicationsn s- Applications On Line\3 -2006 - Pamit Application.doc Revised: 9 -2006 bb r4 �Pv g i:Cc c -6 . °I an.„ .N' Pt crscn c �/ _ t Call before you Dig: 1- 800 -424 -5555 ❑ .. Highline ❑ .. Renton ❑ .. Seattle ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Page 3 of 6 Unit Type: Qty Unit Type: Qty " Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator— Comm/Ind MECHANICAL PERMIT INFORMATION 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E - Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ g 00 v t ( Scope of Work (please provide detailed information): Cer (+4 I . X14 5 k. o� b Cr COI ef (Zpne= 1 / te r 1 .I J l S'/1Y1 l�fc?TO r – - 0 PAC . SA" `• [ v�tM G..rt z-k �az ;1 �I •/ C rlau+? j jig;, Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric ❑ Gas .... Other: (L .0 X Indicate type of mechanical work being installed and the quantity below: Q:Upplications\F « ms- Applicalions On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 Fixture Type: Qty ; Fixture Type: QtY Fixture Type: Qty Fixture Type: Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Contact Person: E -Mail Address: PLUMBING AND GAS PIPING PERMIT INFORMATION - 206-431-3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: p Mailing Address: )J k Contractor Registration Number: K Valuation of Plumbing work (contractor's bid price): $ IJ aA Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): k2 J . Building Use (per Intl Building Code): JJ J Occupancy (per Int'l Building Code): �J Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:Mpplications\Fotns- Applications On Line 3 -2006 - Permit Applicatioadoc Revised: 9 -2006 bh City State Zip Day Telephone: Fax Number: Expiration Date: Sewer: Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Duildinc and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). j'lumbinc Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: Print Name: rt + gib■. Mailing Address: .57-;e - "Pk - AL . 6 S a Q:Mpplications\Fams- Applications On Lint3 -2006 - Permit Application.doc Revised: 9-2006 bb City Date: /2 67 Day Telephone: '26 376' 22 !a I4/A 9ffe State Zip Date Application Accepted: 0(4 WA- Date Application Expires: Staff Initials: (,.. Page 6 of 6 Doc: RECSETS -06 RECEIPT NO: R07 -01115 Initials: JEM User ID: 1165 Payee: PACIFIC TELECOM SERVICES LLC SET ID: S000000789 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONSS: Set Member Amount ar. -213 °: MO'T=133 TOTAL: ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www. ci. tukwila. wa. us 128.53 246.53 375.06 TRANSACTION LIST: Type Method Description BUILDING - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE SET RECEIPT Payment Date: 06/12/2007 Total Payment: 375.06 Amount Payment Check 12913 375.06 TOTAL: 375.06 Account Code Current Pmts 000/322.100 68.32 000/322.100 203.22 000/345.830 99.02 000/386.904 4.50 TOTAL: 375.06 91'17 06/12 7716 TOTAL 375.06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 0323049057 Permit Number: D07 -213 Address: 11030 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 06/12/2007 Applicant: SPRINT Issue Date: Receipt No.: R07 -01318 Initials: WER Payment Date: 07/09/2007 03:21 PM User ID: 1655 Balance: $0.00 Payee: MATT ENGLESBY TRANSACTION LIST: Type Method Description Amount Payment Cash 17.38 ACCOUNT ITEM LIST: Description BUILDING - NONRES Account Code Current Pmts 000/322.100 17.38 Total: $17.38 Payment Amount: $17.38 0084 07/09 9710 TOTAL 17.38 doc: Receiot -06 Printed: 07 -09 -2007 Project Type of Ins ection: ( v Address: ii Date Called: Special Instructions: Date Wanted:j -0 `.� � a.r Req ster: ✓'!a I C, _ . B b tti Phone No: 0-5 " Z o -0,97 ( INSPECTION RECORD N . / � Retain a copy with permi INSPE • NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 COMMENTS: Ci:A7v1/`7 1E7elf -71tA4/ Approved per applicable codes. Corrections required prior to approval. 4 pe . r: I Dat,: ii. iajr I ` J �" V " G 00 REINSPECTION F REQUIRED. Pr' r to ins 1 .r ection, fee must be ■ 'aid at 6300 Southcenter Blvd., Suite 100. all the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Type of Inspection: cNAL.- Address: I1o3o E Mort2� WY S. Suite #: Contact Person: C2A(� Special Instructions: Phone No.: 2c. 20f) -- tY-1/3 1 n C, 1r, t-- ry t..- -- U O— Occupancy Type: M - - - ,.316 - D ►l - - 0, DI- A C 7" vJ ( S U ('?t 102- '17-) M. ►4, t- ryt t r ort1 - - PL (? n Project: L L Wp Type of Inspection: cNAL.- Address: I1o3o E Mort2� WY S. Suite #: Contact Person: C2A(� Special Instructions: Phone No.: 2c. 20f) -- tY-1/3 1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT NA vy - 135 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 j pproved per applicable codes. n Corrections required prior to approval. Date: '/ /&, /o& . rs.. / Inspector: c n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Proj r Vr/ /t/1 Type of I pectlon: A /AJ4 / Address: // D70 f / Date Called: Special Instructions: Date Wanted: _ a , Re nester: Phone No: 07_3 268 - 08 7I i INSPECTION RECORD Retain a copy with permit INSPECTION NO. 72/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 EI Approved per applicable codes. `Corrections required prior to approval. COMMENTS: ,T, -- 4 c-1 D 71/ ..� o 0 REINSPECTION FEE EQUI13Eb. Prior to inspection, fee must be id at 6300 Southcenter B d., Suite 100. Call the schedule reinspection. !Receipt No.: Pro.:._ ) "/ -'7 Type of Inspection: /— / /L r7 Address: - - // 0 -. P //s / / i� j/,L « Date Called: Special Instructions: 01 ; / ; 5_) Date Wanted:, O// /C - 7 (a.rrj. p.m. Requester: Phone No: 2 J _ 3 c%' S • (''L 7/ -:. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. Inspe ENTS: $5: .00 REINSPECTION EE REQU ED. Prior to inspection. fee must be id at 6300 Southcent r Blvd.. ite 100. Call the schedule reinspection. Rg eipt No.: 'Date: DO 7-2/ Project: ' t e / v` / _ Type of Inspect 2O / 1 r i '49 Addres : E , //)03'o s ,c.d pate Called: Special Instructions: ( /2"° 0/2/1(2—'0 / 25 Date Wanted: /,'-77 a.m. p Requester: Phone No: INSPECTION NO. INSPECTION RECORD C j7_,Zi3 Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ❑ $58.00 R SPECTION ICE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: June 28, 2007 Ms. Jennifer Sheckler Pacific Telecom Services, LLC 568 First Avenue South, Suite 650 Seattle, WA 98104 Re: Acoustical Report — Sprint Nextel WA0233/3105995 Elmo -SPAA Site: 11030 East Marginal Way South, Tukwila, WA 98168 Dear Jennifer, This report presents a noise survey performed in the immediate vicinity of the proposed Sprint Nextel telecommunications facility at 11030 East Marginal Way South in Tukwila, Washington. This noise survey extends from the proposed equipment to the nearest properties. The purpose of this report is to document the existing conditions and the impacts of the acoustical changes due to the proposed equipment. This report contains data on the existing and predicted noise environments, impact criteria and an evaluation of the predicted sound levels as they relate to the criteria. Ambient Conditions Code Requirements Stewart • Alt Allaoua • Perkins Existing sound levels were measured on site with a Larson -Davis 820 sound level meter on June 27, 2007 to determine ambient sound levels. Measurements were conducted as close to the proposed location as possible and the property lines in accordance with the State of Washington code for Maximum Environmental Noise Levels WAC 173-60 -020. The average ambient noise level was 60 dBA, due to traffic noise on East Marginal Way South and the nearby Seattle Police Officer's Firing Range. The weather during the measurements was overcast and the roads were dry. The site is located within the City of Tukwila Zoning jurisdiction on property within an Industrial district. The receiving properties are within the same Industrial district. The proposed new equipment consists of an emergency generator. The generator will run once a week during daytime hours for maintenance and testing purposes only. Under Tukwila Municipal Code 8.22.040 noise from equipment on a within an Industrial district is limited as follows: Industrial District Receiver: Noise is limited to 70 dBA during daytime hours. Daytime is defined as the hours between 7 a.m. and 10 p.m. Additionally, Tukwila Municipal Code 8.22.050 allows that during any one -hour period, the maximum permissible noise level may be exceeded by 5 dBA for a 15 minute period. INCOMPLETE LTR#.�_ 222 Etruria Street, Ste 100 Seattle, Washington 98109 t. 206.839.0819 f. 206.839.0824 DOE77U3 JUN 2 6 ZiUI PERMIT CENTEI- Line Application Factor SE 1 Combined Sound Pressure Level at 23 ft. (dBA), Lp1 65 2 Distance Factor (DF) Inverse - Square Law (Free Field): DF = 20log (d1 /d2) -7 (54 ft) 3 New Equipment Sound Pressure Level at Receiver, Lpr (Add lines 1 and 2) 58 Sprint/Nextel WA0233/310595 Elmo -SPAA Therefore, the generator must not exceed 75 dBA when running during daytime hours for maintenance testing. The generator is exempt during emergency operation. Predicted Equipment Sound Levels Emergency Equipment The proposed equipment includes one MQ Power 20 kW Diesel Generator. According to data obtained from the manufacturer, the generator with a Crystal Quiet Enclosure will produce a sound level of 65 dBA at 23 feet. This generator will run for emergency purposes only when an unexpected power loss is experienced. Power losses are expected to occur very rarely at this site. According to code exemptions, the generator is exempted from the noise statutes since it is used for emergency purposes. In addition, the generator will run fora maximum duration of 15 minutes once a month during the daytime only for maintenance testing purposes. The nearest receiving property is 54 feet southeast of the equipment location. The predicted sound level at the nearest property is shown below in Table 1. As shown in Table 1, the combined sound pressure level from the proposed equipment cabinets at the nearest receiving property is 58 dBA which meets the 75 dBA 15- minute noise code limit. Please contact us if you have any questions or require further information. Sincerely, SSA Acoustics, LLP Erik Miller -Klein Alan Burt Senior Technician Table 1 Application Factors and Predicted Noise Levels Proaosed Generator Page 2 Reviewed by, Acoustical Consultant RECEIVE, JUN E13 2007 PERMIT QENTE I • RE JUN PERM Pacific Telecom Services, LLC June 28, 2007 Bill Rambo Permit Technician City of Tukwila SUBJECT: Development permit application D07 -213 Sprint Generator —11030 East Marginal Way Dear Mr. Rambo, This letter is in response to the additional information letter I received from you dated 6.15.07. Please see the attached noise reports required by the City of Tukwila's building code 18.58.070. Comment: 1. Pursuant to TMC 18.58.070 "Any facility that requires a generator or other device which will create noise must demonstrate compliance with TMC Chapter 8.22 "Noise ". A noise report, prepared by an acoustical engineer, shall be submitted with any application to construct and operate a wireless communication facility that will have a generator or similar device ". Response: Please see attached Noise report Enclosure: (4) SSA Noise Reports If you have any questions or need additional information please call or e-mail me. Sincerely, Matt Englesby Pacific Telecom Services 568 1' Ave S. #650 Seattle, WA 98104 menglesby @ptswa.com 206 - 310 -2290 RECEIVED JUN 4/8 PERMIT CENTER 5681st Avenue, S, #650, Seattle, Washington 98104 • [Phone) 206.251.6384 • [Fax) 206.903.8513 • www.ptswa.com DEPARTMENTS: Bu ,1,()G ng Division Public Works Complete L \W I COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -213 DATE: 06 -28 -07 PROJECT NAME: SPRINT GENERATOR SITE ADDRESS: 11030 EAST MARGINAL WY S Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) 5111 �- -3- °}A Fire Prevention Planning Division Incomplete Permit Coordinator DUE DATE: 07 -3 -07 Not Applicable Comments: "t • Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ No further Review Required DATE: REVIEWER'S INITIALS: DATE: DUE DATE: 07 -31 -07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D07 - 213 DATE: 06 -12 -07 PROJECT NAME: SPRINT SITE ADDRESS: 11030 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division P •Iic orks - *01 Complete ❑ Comments: PERMIT COORD COPY REVIEW /ROUTING SLIP Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: (j 1, ---07 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping PW El Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Fire Pt Planning Division DATE: DATE: Permit Coordinator DUE DATE: 06-14-07 No further Review Required lotel Not Applicable E C DUE DATE: 07-12-07 Approved with Conditions ❑ Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: C Z ' " Created: 8 -13 -2004 Revised: A City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: S , v� �, P n P re.ke - `o O Ea s Project Address: 'i t. n 3 E j \,,/a Contact Person: E ,., I e � 1 Phone Number: 2 b 3 d - 7 2 4 /0 Summary of Revision: j\L : S,. R e of Steven M Mullet, Mayor Steve Lancaster, Director 07 -213 RECEIVED terre OF KWILA JUN 28 2007 RMOT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revise i n Received at the City of Tukwila Permit Center by: Entered in Permits Plus on l '07 \applications\forms- applications on line\revision submittal License Information License EAGLECS972QL Licensee Name EAGLE COMMUNICATION SRVCS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602037526 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 1026 26TH AVE NW, SUITE C Address 2 12/01/2005 City GIG HARBOR County PIERCE State WA Zip 98335 Phone 2538589611 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/13/2003 Expiration Date 6/26/2009 Suspend Date Separation Date Parent Company Previous License EAGLECNOO6L6 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PERRYCOOK, JAY PRESIDENT 12/01/2005 PERRYCOOK, TAHIRIH SECRETARY 12/01/2005 PAGE, KEVIN S PRESIDENT 11/13/2003 12/01/2005 PAGE, LAURA S SECRETARY 11/13/2003 12/01/2005 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= EAGLECS972QL 07/03/2007 )1 Sbt Together with NEXTEL WILLOWS RD NE SUITE 100 10545 S REDMOND, D E UI PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S„ Suite 650 Seattle. WA. 98104 (206) 342 -9000 Fax: (206) 903 -8513 CURRENT ISSUE: CONSTRUCTION DRAWINGS r�{ .�'' 'JrI .� fi w III ��. I I} p I I I F l Va'"4ft0; n:"CY4„��.. ray��f,YEttt,i +aV,I MJW�P�LI I MV F!� C L� '? 1 , 7r'r,"t,���� t4ll�3V.'MJ�h7V'. 2' �:' MI�III, J. Idefi"II. 1, I Ind II . If.VL'.� .: n �l? ".. C'e' ,. : i.. l i W tip:: y L : I . n, I . 0 , APPROVALS: DATE: SPRINT /NEXTEL ,1 LANDLORD • CONST 0 S /A. Together NEXTEL R F - with ZONING: A &E- PAA N ` P 310595 • N = 1 J 0. ' rn ELMO iL'W hll t ' a 1' Ililuwf"�'IF YI � e 4 6 phi I�II'IV^ L1 'vF I M e IW. �� ,Nd1 I { l q 1 I'H -d MI p - _ r.Vn.W Y.... al�' aaT"_.1. 141J6II.i y' I 1 ° . ..,. I�r�L�w.�.. l't4`Irtn P. 1 G.I I. '.:' My ,I +�Ir � ,,.f I,'✓? . WA0233 / 310595 r -N PROJECT INFORMATION �r DRAWING INDEX u11 PROJECT DESCRIPTION: SPRINT — NEXTEL PROPOSES TO AMEND AN EXISTING UNSTAFFED TELECOMMUNICATIONS FACILITY WITH THE ADDITION OF A 20KW DIESEL GENERATOR AND FUEL TANK MOUNTED ON A NEW CONCRETE PAD. SITE ADDRESS: 1 1030 EAST MARGINAL WAY S TUKWILA, WA 98168 PROPERTY OWNER: AMERICAN TOWER CORP 10 PRESIDENTIAL WAY WOBURN, MA 01801 ATC SITE NAME: ELMO — SPAR`, ATC SITE NUMBER: 310595 APPLICANT: SPRINT /NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PROJECT CONTACT: MATT ENGLESBY PHONE: (206) 310 -2290 EMAIL: MENGLESBY @PTSWA.COM LATITUDE: 47° 30' 2.99" N LONGITUDE: 122° 17' 12.1 " W LAT /LONG TYPE: NAD 83 ELEVATION: 0' AM S L PARCEL NUMBER: 0323049057 CURRENT USE: TELECOMMUNICATION FACILITY PROPOSED USE: TELECOMMUNICATION FACILITY POWER: SEATTLE CITY LIGHT PHONE: (206) 684 -3000 TELCO: QWEST PHONE: 1- 800 - 603 -6000 JURISDICTION: CITY OF TUKWILA ZONING: MIC /H— MANUFACTURING INDUSTRIAL CENTER/ HEAVY INDUSTRIAL APPLICABLE CODE: 2003 IBC CONSTRUCTION TYPE: II —B OCCUPANCY TYPE: UNOCCUPIED PROJECT AREA APPROX 40 S.F. VALUATION: X10,000 r VICINTY MAP : 0' �` :p T -1 TITLE SHEET AND GENERAL INFORMATION G -1 GENERAL NO A - 1 SITE PLAN A -2 ENLARGED SITE PLAN A -3 GENERATOR AND EQUIPMENT DETAILS p �� pig o c"amrsies shall be r , - : :: ds: r' czs I `` � - = -� - ::3 Cua�w i':v�� :ons will require and m Y include additional ° r , �'- . r: �•o x �, m . I.5 ,$ - NOTE: • r '. S - Can't r - _ '" I '* -;-.,- �' ^ �7 � � �' ' � 4�: ` 51, a t'Y -:, V I - – � ' = tit st i 4 ` '� � _ � C 11r =a� 99 4 "' _ , r" ► ' 58 .,..,. A-4 GENERATOR PAD DETAILS E -1 GROUNDING PLAN AND ELECTRICAL NOTES E-2 MQ POWER DIESEL GENERATOR AND ALARM WIRING E -3 ATS CABLE SCHEDULE AND ATS ALARM WIRING E -4 ELECTRICAL DETAILS t , _ _ F� ,. „� Permit No. 4 yep 5t , t Pf , L _J � I ��h I T ': , . '�'. ( Tukwila 9(10 v t t'.._._...___....._._ T. `,/ V N;W � Exit 157 s� y a �+ �8�"... e i .,. , � a ''Y ` I r u � °" '� �,. a . ` ,, - yU 1•� ` .._ A ^�@ " 4. r ; i a x w y SEPARATE PERMIT REQUIRED FOR: edhankal Electrical ■Plumbing D �a Piping City of Tukwila BUILDING DIVISION Plan review cpproval Is subject to error Appro cr c LCtion do -•es not authorize ��.;_ documents the a violati:n c; u-7 cf cod «• • - or o �-ip pp:c'�z:1 i :_:.] , -✓ (_:-.d - .nd:tions lede By ; `` t «. 4 ' .�`, te e, _ s 91 rith sf �^t r � , ,-�.� ys, Si , � 1'160 _ «_, ky Ail�nto +nrn lit w m, .�- .- .- .......,. _ �... 599 , J � _.,, A � Date: 7 ? 7 dV HI HI \ City of Tukwila >ID L7-, BUILDING DIVISION Na W ag W a8 SNOISIAJN 05/29/07 LO /I I /90 v,tir ,7 7r F' {l.t" I. 1�1 i r ,�f tl ^ sk+ . x,.. s 1 , I1.. ..rA.. ,... r. r r. I . I ''1'''','L t w a r 1 , i 1s r. F i.5 t �.1, :.. � d � .a ,ir .'. r., w. Itl I t 4,, v I , - _ k,c W. , _ .� .... .m: � ...�. ..r h .,f., � ,. � ....� .� .. ... � a v . �.. , w� , _.. ... .1.� . . r v 7 y _•_ _ �_ _'�', � .," M..�......w _ • '' CO s 13tn c ir. ; �" '` r ti. f. 1 PROJECT TEAM ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION DESIGN TEAM PRIME CONTACT 4 DRIVING DIRECTION 3M :r. l ;�� ro o ; y ilo Ij , � I THOMAS R. HOLLAND, AIA SPRINT /NEXTEL PACIFIC TELECOM SERVICES, LLC 10545 WILLOWS RD NE 568 FIRST AVE S, SUITE 650 SUITE 100 SEATTLE, WA 98104 -2804 REDMOND, WA 98052 CONTACT: STEVE ISHIHARA CONTACT: BRYAN ADAMS PHONE: (206) 342 -9000 EXT. 412 OFFICE: (425) 278 -2109 FAX (206) 903 -8513 EMAIL: 51SHIHARA @PTSWA.COM ZONING CONTACT PROJECT MANAGER ' to ll i �;� 11'x' II o, , I �, ", p�'iiarf di �. r hh'y x " II DEPART 10545 WILLOWS RD NE, REDMOND, WA 98052 ON WILLOWS RD NE (SOUTH) T URN RIGHT (WEST) ONTO SR -908 [REDMOND WAY] TURN OFF ONTO RAMP MERGE ONTO 1-405 (SOUTH) AT 1 -405 EXIT 11, TURN OFF ONTO RAMP MERGE ONTO 1 -90 (WEST) AT 1 -90 EXIT 2B, TURN OFF ONTO RAMP MERGE ONTO I -5 (SOUTH) AT I -5 EXIT 158, TURN OFF ONTO RAMP BEAR RIGHT (WEST) ONTO S BOEING ACCESS RD TURN LEFT SOUTH (SOUTH) ONTO E MARGINAL WAY S ARRIVE 11030 E MARGINAL WAY S, SEATTLE, WA 98168 Jj1 < o ir 1 TITLE SHEET AND GENERAL INFORMATIQ J ] b X1 1 t ' PACIFIC TELECOM SERVICES, LLC PACIFIC TELECOM SERVICES, LLC 568 FIRST AVE S, SUITE 650 568 FIRST AVE 5, SUITE 650 SEATTLE, WA 98104 -2804 SEATTLE, WA 98104 -2804 CONTACT: MATT ENGLESBY CONTACT: LORI CHASE PHONE: (206) 342 -6391 PHONE: (206) 342 - 6386 ;:iEOEIVEU C;1 OF TUKWILA E —MAIL: MENGLESBY @PTSWA.COM EMAIL: LCHASE @PTSWA.COM JUN 1 2 7001 r1' J0B # DRAWING # WA0233 -L I '.Irr w.. r.'w, � 1 :... y ��., .. �r� °h r'.. �.. �'�I "Y '�' �, r:.. �...� �•. 1 i . vM I d..., .I d.d 1 ��dY '�:�r 4� n .1 „ Y °.a I M b rs I [W s � ": h II S. r y� N d',rr I I 1N Y .' 1 N w, I I 3 9 +k IL J L Y. qre zw i� 1y.. y� :T a k, K.... 18,. r D ,' L >S F. (.' II Y N ,M •M� z I. r.. s, 4 f N II Cif m '�. " '...... Ir 4.. b l�. 7 NIr •a. F I�� I I I k! h ! Y 0'W I V 1,Sly. O.�S I 1li 41. `°�, �IrV � �� 'G.. 'k C' �' V "" 1 , v. I J' : 'I'$ l V 0. Sr "�.0 Vr J'' ,. t«I . , : . . o r� .. .'f , � �rM .. , .� y - Wf . . .� ,. . ..R' r . , . .. , .1 .. . . � ,.. r ,r yr �, s , ry . �� ��� � . ,..a � +.o. ... .r. h I� , .�, 1 � _r. n. n FI ,ot. ... . {� . Y. .x W ....� 1. .. 1�" I ...n� r 1 Y I.. .�� .r ,� 4 r �!. rN. � NN .. Y.�, I r ... .. r• 9 .. r , . .. � `K i. �."i ,.. I d. � r. � s. ., � : . °�. ,, 4, n I d d '7 ,: ;g , rnrv� 1 a 1 � , � , 1 , r} � r� r tr. , � 1 , 1 � 1.. , r, �. .. � �� �. r'� �.. �. � v I I ��� . ,r. 1 . � �, �. I ,,, 1 SP 1 .. ,.. . v. f .. .�. . . �( rl. ,r .. I.. .� I ��.. � :. .., � �.. � �I� ��rli W. s .�. rn.• I ilu � I �� F ..... . ... .. v.. .� � � . r� .. f 11 � r. .,. JI�. r r, F � � � � i :L I r. r1 �. 1+ , r , µ ,w .a 1 � �b ,� 1 � �t. ,. :..n L r.. ., x' a .^ :'.. .:.uli , ... NE.. 6. r .. ,... . .d ,.. �._, L � _i �. .0 ...._. 4f:.. ..a .. n,. � _� _,.� .. 1. .�, re. �.., , a � w. .�� .... 'L3 .��. �� � iw ., �� w. .9Y]� f I.� S t .V "L � r n "M u V � � � .V ._ A... .. !. I . �. �. f I. .. 1 � I.dF�k IF 4-� P. �. � 1 ,' e� 6.. I:r ..gyp �.., , •N.ie �.. � ... 1 c I .��..� � d. m . , �_ . W r .� r tl r, ... � ,. I 11 Ia r w .� I .�; 1 1 ..; I :�u ,..., ,.. ... .ar�...a_�, y,. .m. .� .iur1�, a>?_ .J1 ca .ir'.IVSrIS_�.m _� �>r_.t�a. _.r. n x I 2i , ,ailP 5 �I w a rrl�.�., : � , >w . .. .°:. I ; . a.I., Irr -a1., v - ..� ._ .-. '�)< { .d � uL t ..u>c�l� �z. �. ��Vu� i5 ». a it I,. � :�,.�rI��NV81"W�,�>.., a�. �.� aN, rd d"��� � Jl, r �ha�r.� wr, „�rm�«trrl.� ooh, ��G,. ��u 1 �. .M1J: r. ✓r.mR�I lrrlr Id.NN a .. 1h�. �ml��_,u .i Fa. I �a Wrw�� LdaWa h ^ �.,�. a& �I�r��ro,., a�u� ,n�,_I�mrL..�.F1e�,a..,_�:r�as �.GrL . r c i.a.I . J a. � y o-h r< �� a 1 r,I a 1 L r .. 4 M ,. R, _ . � �: w r . W r 3 1 6i I 11 I ... k � ,,. r I ,� F ,. 1 , d� I,,..ln, a k ,rq � ,11 G ” u. , . � w L� ,�I �. r � �r� . .. _. , I , IhI . u� I , . • _ 1 1 F � .,. . . ur'relrrL�...r"�C�.r a�:c,. h: �r.u.,,. � �. +.. �. ,.- ,> I y....r,. � 1 �r.��, ,iv.. .r. 19y:r. '�.� �I�I�M,�.w" :� w� III I , 11,1 I CI �I , 1�{9.,! �. , I � 1 u'� � ,' r1 JF. Ir REVISION I a dV Hl I Hi WA0233 G -1 REVISION I o 7 NO WG8 INO8 REVISIONS L0 / 6Z /50 LOII /90 ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION <0 G GENERAL NOTES JOB # DRAWING # WA0233 G -1 REVISION I o STRUCTURAL STEEL NOTES 1. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND IN ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE NOTED. 2. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC AND AWS D1.1. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION ". PAINTED SURFACES SHALL BE TOUCHED UP. 3. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE (3/4 "0) CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 4. NON- STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A 307 BOLTS UNLESS NOTED OTHERWISE. 5. INSTALLATION OF CONCRETE EXPANSION /WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY GOVERNING CODES, SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE LOADS. 6. INSTAL_ATIONS WHERE THE GENSET IS LOCATED NEAR EXISTING CABLE TRAY SHALL HAVE A NOTE ON THE DRAWINGS CALLING FOR GRIP STRUT INSTALLATION OVER THE TRAY FOR TO PROVIDE FOR A WALKWAY FOR TECHS AND SERVICE PERSONNEL 7. EXISTING PLATFORM INSTAL_ATIONS SHALL INCLUDE THE INSTALLATION OF AN ANGLE UNDER THE STRUCTURAL MEMBER OF THE PLATFORM TO SECURE THE GENSET TO THE PLATFORM IN LIEU OF THE GATING. 8. SURFACE MOUNTING OF CONDUITS SHALL BE AVOIDED AT ALL POSSIBLE LOCATIONS WHERE PEDESTRIAN TRAFFIC CAN OCCUR_ WHERE THIS IS UNAVOIDABLE, GRIP STRUT BRIDGING SHALL BE CALLED OUT FOR INSTALLATION TO PROTECT THE CONDUITS AND POTENTIAL FOR PERSONNEL TRIPPING HAZARDS. ELECTRICAL \OTES: 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROvI TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL BE COPPER THHN /THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 4. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 5. RIGID CONDUIT SHALL BE USED WHERE DAMAGE CAN OCCUR FROM VEHICULAR TRAFFIC OR EQUIPMENT DELIVERY EXERCISES. 6. ATS AND GENSET LABELS ARE TO BE PROVIDED AND INSTALLED WITH SERIAL AND CASCADE NUMBERS FOR THE ATS AND GENSETS. LABELS SHALL BE ATTACHED VIA ALUMINUM OR SS SCREWS --- CONSTRUCTION MANAGER TO PROVIDE TO SUBS FOR INSTALL AT SITE, DUE TO POSSIBLE ASSET TRANSFER ACTIVITY, UPON RECEIPT OF LABEL SPECIFICATION FROM SPRINT /NEXTEL. 7. NEW INSTALLATION SHALL BE PVC CONDUIT, USE SCH 80 ABOVE GROUND AND SCH 40 BELOW GROUND. ALSO REFER TO CONSTRUCTION MANAGER DIRECTION FOR ANY CONDUIT EXPOSED TO TRAFFIC (VEHICLE OR FOOT). 8. CONTRACTOR TO PROVIDE A NEW 66 BLOCK IF REQUIRED, WITH FURTHER ROUTING TO THE RBS EQUIPMENT CABINET AND LEFT WITH A 2' COIL OF WIRE. ALARM CABLING IN THE TELCO CABINET SHALL BE INSTALLED IN A NEAT FASHION WITH A 6" SERVICE COIL. CONTRACTOR SHALL NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 BLOCK CE\ ERAL OT -S: 1. THE SPRINT /NEXTEL METHOD OF PROCEDURE (MOP) MOPS 2061108 INSTALLATION OF PAD MOUNTED GENERATOR SETS IS THE BASIS FOR ALL TECHNICAL INSTAL_ATION SPECIFICATIONS; AND IN THE EVENT THERE IS A CONFLICT BETWEEN THESE CONSTRUCTION DOCUMENTS OR THE INSTALLATION CHECKLIST AND THE GENSET MOP, THE CONTRACTOR SHALL FOLLOW THE DIRECTIVE DESCRIBED WITHIN THE MOP AND CONTACT CONSTRUCTION MANAGER TO APPRISE. EXCEPT NO PORTABLE GENERATOR S/0 CORD STILL BE REMOVED 2. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 3. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 4. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 5. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER_ DRAWINGS WERE PREPARED FROM SITE SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY PACIFIC TELECOM SERVICES, LLC. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS vIUST BE SUBMITTED TO, AND APPROVED BY, SPRINT /NEXTEL PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. 8. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. ALL INSTAL.ATIONS SHALL BE 100% CLEAN OF ALL DEPRIS AND METAL FILINGS SHALL BE REMOVED FROM ENCLOSURES, SITE AREA, FIXTURES, P_ATFORMS, ETC. 9. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER VERBALLY AND IN WRITING. 10. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS /CONTRACT DOCUMENTS. 11. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. GE \ERAL \ OTES (CO \T.): 12. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S /VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 13. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 14. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 15. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE v1ARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 16. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2 -A1OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 17. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 18. THE ARCHITECTS /ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT /ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 19. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING SLI9 a , 2007 NORMAL BUSINESS. 20. CONTRACTOR SHALL CALL WASHINGTON UTILITY COORDINATING COUNCIL SERVICE FOR UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION 1 -800- 424 -5555. 21. IN CASE OF CONFLICT BETWEEN THE AFORE REFERENCED SPRINT /NEXTEL STANDARDS AND INSPECTION CHECK LIST, THE GENERAL CONTRACTOR SHALL CONTACT CONSTRUCTION MANAGERS' PROJECT MANAGER TO RESOLVE, IN WRITING, ANY DEVIATIONS. RECEIVED CITY OF TUKWILA JUN 1 2 7007 T CENTER Sprint, 14 Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 Phone: (206) 342-9000 Fax: (206) 903 -8513 THOMAS R. HOLLAND STATE OF WASHINGTON , A0233 / 310595 ELMO-SPAA 030 EAST MARGINAL WAY S TUKWILA, WA 98168 Spr i n t. )), ;#' Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 IIMIErlinin. PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 Phone: (206) 342 -9000 Fax: (206) 903-8513 V -psi 'cO SO v N A ro#.. 0 ° �� #0.1......... 2\IA 0 \ i \ / / 0 ' \ •••°. - O P P� 0 \ ` 0 ...... 0 0 _ 0 0 , 0 0 /EXISTING 0 o 0 0 \ 0 - " \ A--- -1 \ \ 0 0 EXISTING PARKING \ Yt r 0 0 �y1 ) 2B01 -- ._._ RECEIVED CITYOETLJKWILA JUN 1 ?E.: ....... .. ._..... 7007 i,. -aa,E; r L_ %b) Y.° ciV HI HT NG W08 WOG REVISIONS 05/29/07 L0 / /90 ;ISSUED FOR PCD REVIEW 'ISSUED FOR CONSTRUCTION BUILDING .....------------ ....... PROPERTY LINE • vc, LOT EXISTING 125' -0" ATC MONOPOLE (ANTENNA ARRAYS NOT SHOWN FOR CLARITY) A.1 SITE PLAN — JOB # DRAWING # SCALE: (24" X 36 ") I :: =:_ ::SATE (1" -0" 32' PLAN 1 WA0233 A -1 24'16' S' 0" 32' REVISION I 0 N I) , Sprint, Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 ■Ir Ii PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 -fr ,+ 1 �o X — o f k \ PROPOSED 4'-O" GATE 1111. ge. 1 // EXISTING CHAIN LINK FENCE TO BE REMOVED EXISTING PROPOSED 20kw DIESEL NEXTEL GENERATOR f FUEL TANK BUILDING \ 0 \ � \ /1 10 • o000 \ �` 0 \ \ 0 ' • p o • PROPOSED NEB \ UNDERGROUND GENE RATOR �` �� CONDUITS (APPROX. O ' _ T \ f AA A 0 ai v mo g 1 0595 D _` WAYS Z \ PROPOSED NE) TEL ATS LOCATED 0 O O O O �. WITHIN EXISTING SHELTER (FIELD \ VERIFY EXACT f f llk f ,- \ S f EXISTING CINGU JAR \ EQUIPMENT ON f. A - 3 f CONCRETE PAD / � f / • 1, f f f EXISTING CINGU_AR & 0 � dV HI HI EXISTING NEXTEL 11' -5" X 20' -0' T- MOBLIE WAVEGUIDE -f- \ ollk • \\ \ �c EQUIPMENT SHELTER \ \ I >D NC WO8 WO8 EXISTING NEXTEL CONCRETE STEPS \ 40 010 1 t I LANDING \ Of EXISTING NEXTEL GENERATOR PLUG REVI \S 05/29/07 LO/I I /9 *, sWE EXISTING NEXTEL WAVEGUIDE ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION o , \ EXISTING 125' ATC MONOPOLE AU 'I), 21 -0" EXISTING T- MOBLIE EQUIPMENT ON .,c \ _,_�_ --- (ANTENNA ARRAYS NOT SHOWN FOR CLARITY) ? , y _� Fyn CONCRETE PAD \ `\ f N , ., ry. \ EXISTING 6' ACCESS GATES (4) -0" k - k f � -■'-'X j \ EXISTING NEXTEL UTILITY RACK - -'V. - k EXISTING 6' -0" HIGH CHAIN LINK FENCE f a■ WITH (3) STRANDS BARB WIRE / + 1 i ( i f 7 ,- E CEIVEJ CITY r)E TUKWILA JUN 1 2 7001 -; .T Q o A — 2 ENLARGED SITE PLAN JOB # DRAWING # 2 WA0233 A -2 SCALE: (24" x ") /$ " =1' -0" SCALE: X 17 ") 3/16 " ENLARGED SITE PLAN REVISION I 0 (11" =1' —D 3 ; , 0 » 3, � i *hit ,o. Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 (206) 342 -9000 Fax: (206) 903 -8513 7" 54 EXTERIOR WALL ASCO 7000 SERIES AUTOMATIC ASCO 7000 SERIES AUTOMATIC 1' -6 " TRANSFER SWITCH (30 -230 AMPS) TRANSFER SWITCH (30 -230 AMPS) �• 75 —.50 COMBINATIO PILOT KNOCK —OUTS. 1 , — 0 >> 1 „ 1 2 4 (4) .43 DIA. GENERAL NOTES MOUNTING HOLES / q TOP AND BOTTOM 1 ---•1' / / / TOP VIEW INTERIOR WALL 1. TYPE 3R/4/4X/12 WALL MOUNTED ENCLOSURE. o o .IN cv I ' - x Q 10 4 .37—DIA. EXTERNAL - - TYP TOP AND BOTTOM ( ) DIMPLED MOUNTING HOLES 1'-6" 9 " 1 - 2. FINISH TYPE 3R/4/12: ANSI 61 GREY. TYPE 4X CONSTRUCTED OF 12 GAUGE 304 LOAD ^ - - - " - I• I I I rld I I GROUND LUG _ ESCUIOHEUN NOUHRNO • 1 I 1 - STAINLESS STEEL. 3. PLATED DOOR CLAMPS AND PADLOCK EMERGENCY HASP ON LEFT SIDE. 4. SINGLE DOOR HINGED 0 N RIGHT 5. TERMINALS — SCREW TYPE LUGS FOR EXTERNAL POWER CONNECTIONS. 6. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. GROUND LUG MOUNTING STUDS �e oa i '' '' • •' LOAD �'- �I� r• I OR w ESCUMHEO coHtHOLs MOONING _ i • y' f ` +mw \A�� F !� 1 �;; � ' SOLID NEUTRAL NORMAL p LID I : Id - EMERGENCY _ I I- ■■i jjj 1 I � 's ® �, o00 °O ■ ° F. 1 1 I F �� ��� o SOLID NEUTRAL NORMAL �� r; „0 - ,Z o , . a 7. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. :,. L << L L — — — — MOUNTING STUDS 8. NEUTRAL CONFIGURATIONS: AN OPTIONAL FULL RATED NEUTRAL CONFIGURATION n r, n n GRADE LEVEL FRONT VIEW ,ek FRONT VIEW AA >. O D '1 T in [O595 � a G) l z ,L WAY S _ ° '1 -I FOR EACH SOURCE AND THE LOAD MAY BE WITHOUT DOOR PROVIDED. WHEN EQUIPPED IT IS IN ONE OF THE FOLLOWING FORMATS AS SPECIFIED BY THE CATALOG NUMBER NO. NEUTRAL TYPE: r - - WITH DOOR KNOCKOUTS: •............... 1'-6" OEM f f FLOOR LEVEL FRONT ,I, VIEW FRONT VIEW \ (A) SOLID (COPPER BUS) NEUTRAL (B) SWITCHED NEUTRAL POLE (C) OVERLAPPING NEUTRAL POLE LEAVE INTACT FOR TYPE 12 REMOVE FOR APE 12 RIGHT SIDE WITHOUT DOOR WITH DOOR GENERAL NOTES NOT AVAILABLE ON TYPE 4,4X N 1. �'PE 1 WALL MOUNTED ENCLOSURE. 2" BOTTOM VIEW SWITCH RATING (AMPS) RANGE OF WIRE 2. STANDARD FINISH — LIGHT GREY, ANSI 61. 3. KEY LOCKABLE HANDLE. 4. REMOVEABLE SINGLE DOOR. 5. TERMINALS — SCREW TYPE LUGS FOR EXTERNAL POWER CONNECTIONS. 6. ® CENTER OF GRAVITY. 7. THREE POLE SWITCH WITH SOLID NEUTRAL SWITCH RATING (AMPS) RANGE OF WIRE 30 -150 (1) #14 TO 4/0 AWG AL —CU WIRE 30 -150 (1) #14 TO 4/0 AWG AL—CU WIRE 200-230 (1) 14 TO 4/0 AWG COPPER WIRE 200 -230 (1) #14 TO 4/0 AWG COPPER WIRE SHOWN FOR REFERENCE. ATS CABINET (OUTDOOR) 4 T ATS CABINET (INDOOR) SCALE: (24 "X36 "): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE SCALE: (24 "X36 "): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE r � 1 / - 6 " � C I \ T.w rr^^ Q dV HI HI 4' -0" >D it 5 , -0 „ �O WOE! W08 TOP ---- -•-• -- GENERATOR HOUSING REVISIONS 05/29/07 L0/ I /90 ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION in GENERATOR VENT PROPOSED NEXTEL i ! 1 � 1, TOP OF GENERATOR FUEL TANK 3/4 "0 EPDXY SET ANCHOR BOLTS, 4" MIN. EMBED (TYP) TOTAL OF (4) BOLTS MIN. 20kw SINGLE SIDE „0 - ,9 SERVICE GENERATOR PROPOSED NEXTEL 77 GALLON DIESEL o =lm p p © VIBRATION ISOLATION TO BE PROPOSED NEXTEL 3' -6" X 5'—O" o0 FUEL TANK r SUPPLIED BY GENERATOR MANUFACTURER, INSTALLED BY O 1 I CONTRACTOR A.3 GENERATOR AND EQUIPMENT DETAILS EXISTING GRADE CONCRETE PAD • ••... FRONT SIDE BACK . . 4 •v 4 a 4 ;IEOLIVED Bid' OF TUKWILA JUN 1.9 711117 4 d' a d GENERATOR FOUNDATION SECTION JOB # DRAWING # SCALE: (24 "X36 "): 1/2"=1'-0" SCALE: (11"X17"): 1/4 " =1' - 0" — �_ 2 SCALE: (24 "X36 "): 1 = 1 ' -0" SCALE: (11"X17"): 3/4" = 1' - 0" — r WA0233 A - 3 REVISION I o df/ HI H1 WA0233 A -4 REVISION I 0 :A 1.17 NG W Q9 WQ8 �Q SNOISIA tN 05/29/07 LO/ 1 /90 ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION a A.4 GENERATOR PAD DETAILS JOB # DRAWING # WA0233 A -4 REVISION I 0 NOTE: REFER TO ARCHITECTURAL DRAWING FOR LOCATIONS c3-'\ c \ 12" MIN COMPACTED CRUSHED AGGREGATE UNDISTURBED SOIL / 11 #4 REBAR @ 12" r 0.0 . EACH WAY @ MID DEPTH 1'-6 PROPOSED NEXTEL 3' -6" X 5' -0" CONCRETE PAD PROPOSED NEXTEL 20kw SINGLE SIDE SERVICE GENERATOR (ABOVE) AIR INTAKE (TYP) 11 6 11 11 8 " 3/4 "0 EPDXY SET ANCHOR BOLTS, 4" MIN. EMBED (TYP) TOTAL OF (4) BOLTS MIN. GENERATOR CONNECTION SCALE: (24 "X36 "): 1 -1/2"=1'-0" SCALE: (11"X17"): 3/4 " =1' -0" 3/4" CHAMFER (TYP) 3" / / in • 2" CLR FOOTING DETAIL SCALE: (24 "X36 "): 1-1/2"=1'-0" SCALE: (11"X17"): 3/4 " =1' -0" #3 STIRRUPS @ 24" O.C. 15 4 3 6" THK CONC S_,B W/ #4 BAR @ MID @ 12" O.C. E.W. THICKED —EDGE CONCRETE FOOTING z / 6" THK CONC SLAB W/ #4 BAR @ MID @ 12" O.C. E.W. 12" MIN COMPACTED CRUSHED AGGREGATE COMPACTED TO 95% DRY UNIT WT PER AST v1 D1557 1 -6 OVERLAP 2' -0" THICKED —EDGE CONC PERIMETER FOOTING / 5' -0" FOUNDATION OUT —TO —OUT #4 CORNER BAR @ TOP & BOT CONCRETE PAD SECTION SCALE: (24 "X36 "): 1"=1'-0" SCALE: (11"X17"): 1/2"=1'-0" (0 _ I N) CONCRETE PAD 3/4" CHAMFER (TYP) 1 SCALE: (24 "X36 "): 1" = 1' -0" SCALE: (11 "X17 "):1 /2" - 1'--0" +I 0 z 0 2 RECEIVED CITY OF TUKWILA JUN 12 7001 1 N) Sprint. Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 Phone: (206) 342 -9000 Fax: (206) 903 -8513 4072 THOMAS R. HOLLAND STATE OF WASHINGTON A0233 / 310595 030 EAST MARGINAL WAY S TUKWILA, WA 98 68 c3-'\ c \ 12" MIN COMPACTED CRUSHED AGGREGATE UNDISTURBED SOIL / 11 #4 REBAR @ 12" r 0.0 . EACH WAY @ MID DEPTH 1'-6 PROPOSED NEXTEL 3' -6" X 5' -0" CONCRETE PAD PROPOSED NEXTEL 20kw SINGLE SIDE SERVICE GENERATOR (ABOVE) AIR INTAKE (TYP) 11 6 11 11 8 " 3/4 "0 EPDXY SET ANCHOR BOLTS, 4" MIN. EMBED (TYP) TOTAL OF (4) BOLTS MIN. GENERATOR CONNECTION SCALE: (24 "X36 "): 1 -1/2"=1'-0" SCALE: (11"X17"): 3/4 " =1' -0" 3/4" CHAMFER (TYP) 3" / / in • 2" CLR FOOTING DETAIL SCALE: (24 "X36 "): 1-1/2"=1'-0" SCALE: (11"X17"): 3/4 " =1' -0" #3 STIRRUPS @ 24" O.C. 15 4 3 6" THK CONC S_,B W/ #4 BAR @ MID @ 12" O.C. E.W. THICKED —EDGE CONCRETE FOOTING z / 6" THK CONC SLAB W/ #4 BAR @ MID @ 12" O.C. E.W. 12" MIN COMPACTED CRUSHED AGGREGATE COMPACTED TO 95% DRY UNIT WT PER AST v1 D1557 1 -6 OVERLAP 2' -0" THICKED —EDGE CONC PERIMETER FOOTING / 5' -0" FOUNDATION OUT —TO —OUT #4 CORNER BAR @ TOP & BOT CONCRETE PAD SECTION SCALE: (24 "X36 "): 1"=1'-0" SCALE: (11"X17"): 1/2"=1'-0" (0 _ I N) CONCRETE PAD 3/4" CHAMFER (TYP) 1 SCALE: (24 "X36 "): 1" = 1' -0" SCALE: (11 "X17 "):1 /2" - 1'--0" +I 0 z 0 2 RECEIVED CITY OF TUKWILA JUN 12 7001 1 N) Sprint. Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 Phone: (206) 342 -9000 Fax: (206) 903 -8513 4072 THOMAS R. HOLLAND STATE OF WASHINGTON A0233 / 310595 030 EAST MARGINAL WAY S TUKWILA, WA 98 68 )1 int. , ,4 1° Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 ' — (206) 342 -9000 Fax: (206) 903 -8513 10" f f \ 1 0 \ _ I- CO - 0 k X © GE \ERAL_ GPO, \DI \G \OTES: 1. EXOTHERMIC WELD ALL CONNECTIONS TO BURIED GROUND RING WITH PARRALLEL TAP WELDS, USE SHORT RODS WHERE STANDARD GROUND RODS ARE NOT USED, SEE CABLE TO CABLE DETAIL. 2. MAKE ALL GROUNDING CONNECTIONS AS SHORT AS POSSIBLE, MINIMUM BENDING RADIUS IS 8 ". 3. ITH CLE GALVA AN ANIZE LL SURFACES PAINT, USE AND NO -OX BRUSH COMPOUND WITH BRONZE WITH BRUSH METAL PRIOR TO METAL TO MAKING GROUND CONNECTIONS, PAINT ALL EXOTHERMIC WELDS TO GALVANIZED OBJECTS W CONNECTIONS. > 4. INSTALL 5/8 r> X 10 COPPER CLAD GROUND RODS IN LOCATIONS SHOWN, DISTANCE 10'-0" MINIMUM TO 15'-0" MAXIMUM BETWEEN RODS. 5. GROUND SYSTEM MUST BE INSPECTED BY CONSTRUCTION MANAGER BACKFILL, PROVIDE 24 HOURS NOTICE. 6. ALL BONDS SHALL BE #2 AWG BARE, THINNED, SOLID COPE ER UNLESS OTHERWISE NOTED. 7. THE GENSET SHALL BE GROUNDED TWICE IN DIAGONAL CORNERS. GROUND TO THE TANK FRAME AND THE SECOND TO THE GENERATOR ENCLOSURE FRAME. IT IS ACCEPTABLE TO GROUND THE TANK AT BOTH LO( JUMPER FROM THE TANK TO THE GENSET ENCLOSURE. THESE GROUNDS SHALL BE ON THE OUTSIDE OF THE UNIT TO BE VISIBLE BY ALL \ � X • ^ if ri '��, \ / \ - \ /�i S O \ ` - f \ GENERATOR FRAME BOND f SEE DETAIL SAME SHEET fir , _ i \ f PROPOSED 20kw DIESEL \ \ GENERATOR ON 3' -6" X \ 5' —O" CONCRETE PAD \ ( OO \\\\ t \ \ \ f \ \ ° k \ o \ ` ° \ f ® PROVIDE AND INSTALL A 5/8" X 10'-0" COPPER CLAD STEEL APPROXIMATLEY 24" FROM GENERATOR PAD, FOR CASE BOND. @:: PROVIDE AND INSTALL A #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM THE GROUND ROD TO THE NEAREST POINT ON THE EXISTING RING. Q4 PROVIDE AND INSTALL #2 AWG BARE, TINNED SOLID COPPER THE FUEL TANK FRAME TO THE FUEL TANK GROUND ROD. CONDUCTOR FROM iwt ATS \DYES: `� r \ o \ \ f 0 O o 0 \ \ \ \ \ f == f \ \ \ L . PROPOSED NEXTEL ATS INSIDE SHELTER -�`- � .� �� -te , -F . fit YS :.+ IF THE ATS IS INSIDE THE CELL SITE ENCLOSURE THE ATS CASE y ,_ _, BONDED TO THE HALO GROUND RING INSIDE THE ENCLOSURE WI AWG COPPER WIRE. IF THE ATS IS OUTSIDE THE ENCLOSURE, IT SHALL BE BONDED TO THE EXTERNAL DROUND RING WITH A #2 AWG SOLID TINNED COPPER WIRE. THE SURGE ARRESTORS DESCRIBED IN THIS MOP ARE TO BE MOUNTED ON THE MOUNTING PATE SOLD BY THE MANUFACTURER. THEY NAY BE GROUNDED IN ONE OF THREE WAYS: T 1. IF THE ARRESTOR MOUNTING PLATE IS MOUNTED ON THE TEL D AND IF THE TELCO GROUND BAR IS BONDED TO THE EXTERNAL GROUND , THE PLATE MAY BE BONDED TO THE TELCO GROUND BAR WITH A #2 INSULATED STRANDED COPPER WIRE AND SUITABLE COMPRESSIONO YPE 2- L S. 2. IF THE ARRESTOR PLATE IS NOT MOUNTED ON THE TELCO BOARD, BOND IT DIRECTLY TO THE EXTERNAL GROUND RING WITH A #2 AWG SOLI ) COPPER WIRE. USE A PVC CONDUIT THROUGH THE SHELTER WALL 45 DEGREE ANGLE TO ALLOW THE GROUND LEAD TO EXIT THE SHELTER BONDING TO THE EXTERNAL GROUND RING. 3. IF AN EXISTING #2 AWG GROUND CONDUCTOR EXISTS THE SHELTER (TO THE EXTERNAL GROUND RING) WITHIN 2FT OF THE MOUNTING PLATE LOCATION, THE PLATE MAY BE BONDED USING A #2 AWG INSULATED STRANDED CONDUCTOR WITH # A COMPRESSION TYPE "C" TAP AND A SUITABLE COMPRESSION TYPE 2 HOLE LUG. MAKE ALL CONNECTIONS TO THE ATS CASE, THE GENERATIOR FRAME, THE EXTERNAL FUEL TANK (IF PRESENT AND IF SUPPORTED BY THE MANUFACTURER) AND THE SURGE ARRESTOR MOUNTING PLATE WITH SUIABLE 2 -HOLE COPRESSION -TYPE LUG AAND STAINLESS -STEEL SCREWS, STAR -TYPE LOCK WASHERS AND NUTS. REMOVE PAINT AT THE POINT WHERE THE COMPRESSION LUG CONTACTS THE MATING METAL SURFACE IN QUESTION TO ENSURE A GOOD METAL -TO -METAL CONTACT. APPLY ANTIOXIDANT TO THE MATING SURFACES. ENSURE THAT ALL UNDERGROUND OR OUTDOOR CONNECTIONS TO A GROUN = ®Ja LvED SYSTEM ARE EXOTHERIvICALLY WELDED (CAD - WELDED). CITY OF TUKWILA JUN 1 2 7007 PERFORM ALL GROUNDING WORK IN ACCORDANCE WITH STDS 2976175, • E' �O :S E CONSTRUCTION STANDARDS (FIELD VERIFY EXACT LOCATION) \ \ \ PROPOSED #2 AWG ATS CASE BOND APPROX. LOCATION OF EXISTING NEXTEL \ \ HALO (CONTRACTOR TO FIELD VERIFY \ ` .0' ,� "' `.-' EXACT LOCATION) APPROX. LOCATION OF EXISTING NEXTEL ■1' GROUND RING (CONTRACTOR TO FIELD ��' �. VERIFY EXACT LOCATION) - -t. -- -* NOTES: EXOTHERMIC WELD GENERATOR FRAME HOLE BOLTED 1. POWER INTERRU IS ALLOWED ONLY UNDER THE FOLLOWING CONDITIONS; OUTSIDE OF THE MORNING AND AFTERNOON DRIVE TIMES, CUT DURATION MUST BE GUARANTEED TO BE LESS THAN 2 HOURS MAX. IF THIS CAN NOT BE GUARANTEED STAND - BY POWER MUST BE CONNECTED OR INTERRUPTION MUST BE PERFORMED DURING THE MAINTENANCE WINDOW. 2.EXISTING DUPLEX GFI ON THE GENERATORS SHALL BE CHANGED OUT TO A NON - GFI OUTLET TO AVOID LOSS OF POWER TO THE BATTERY CHARGER AND BLOCK HEATERS. NON - GFI OUTLET SHALL BE SERVICED BY ONE 2OAMP CIRCUIT IN FLEX CONDUIT. TWO C GALVANIZED COOLING FENCE POST ; j : I/, GROUND LUG, SS HDW #2 AWG TINNED WIRE FINISHED GRADE FINISHED AFTER � ±� 12" MIN du - 4 _ - � � � / 1# < ° NOTE: PREP SURFACE BEFORE GROUNDING - ,� 4. ��' ���� : . i ,�`E<�,',�.. USE NO — OX BETWEEN LUG AND STEEL. `�' "''' USE SAME COLOR TOUCH UP PAINT TO _...._... n!rn li!rn!'n'I 1!M FENCE BONDING CONDUCTOR , �L �' tl .' - ` �i - �I , ► =!I - 1 -r1= PREVENT RUST. CONCRETE FOOTING G E \ E RATO R E RA V E 130\D GROUNDING PLAN AND ELECTRICAL NOTES NOT TO SCALE E E \ C - B 0 \ D \ G DETAIL NOT TO SCALE JOB # DRAWING # SCALE: (24" X 36 ") 1/2' 1' -0" = = ") " GROUNDING PLAN 2 ELECTRICAL NOTES 1 WA0233 E -1 SCALE: (11" X 17 1/4 =1' -0" 2' 18" 1' 6" 0" 2' REVISION I O dV 1 H1 I Hl O +/_ o +/_ GND c n a- GND O O — O O O +/— w 1 +/_ c o GND a_ GND O — O O O O +/_ U r I ._ +. /_, ' o GND c n eL GND O +/_ o +/_ GND E CND O O O O +/_ ' o +/_ GND (f) eL GND O — — O O O +/_ o +/_ GND c G N D O — O O O O +/_ 6 o +/_ GND (f) eL CND O - 0 O O O dV 1 H1 I Hl O + /--- ,_ o +/_ GND v GND O O O E - 2 REVISION I o O +/_ +/_ � o CND ( E GND O O O O +/_ o +/_ GND E CND O O O O +/_ 0 o +/_ Of GND v) GND O O O t0/ I /90 O +/_ _ o +/ CND Pf) EE CND O O O id ISSUED FOR CONSTRUCTION 0 O +/_ le5i o +/_ GND P E GND O O O dV 1 H1 I Hl 0 +/_ 1 o +/_ GND u) c GND 0 O O E - 2 REVISION I o 0 + /_' o + /_ GND v GND 0 O O 0 +/_ 1 o +/_ GND c 0_ GND 0 O O 0 + /_ 1 o +/_ GND c a_ GND 0 O O t0/ I /90 0 +/_ o +/_ GND c o_ GND O O id ISSUED FOR CONSTRUCTION 0 +/_ 8 +/_ o D CL GND GND O O O dV 1 H1 I Hl MQ POWER DIESEL GENERATOR ALARM WIRING — IDEN JOB # DRAWING # WA0233 E - 2 REVISION I o NO ,WOB WO9 REVISIONS 05/29/07 t0/ I /90 /AD/1 *i OId ?IOd O2115SI ISSUED FOR CONSTRUCTION Q O ALARM EXPANSION BOARD WEAK BATTERY LOW BATT VOLTAGE HIGH BATT VOLTAGE LOW ENGIN TEMP LEAK DETECT v1Q POWER DIESEL PADMOUNT GENERATOR SET REMOTE START 9 K5 10 11 K6 12 13 K7 14 15 K8 16 21 FAULT #1 22 23 FAULT #2 24 ENGINE RUNNING 25 FAULT #3 26 35% LOW FUEL 27 FAULT #4 28 29 FAULT #5 30 GENERATOR FAILURE 31 FAULT OUT #5 32 CONTROL PANEL NC NC NC NC C NC C NC NC C NC NC C NC RED BLK BLK WHT BRN BLU RED GRN RED GRN BRN BLU BLK WHT STRANDED WIRE STRANDED WIRE STRANDED WIRE NOTES: ASCO 7000 ATS /°- BRN L , 5 � BLU SOLID WIRE K K K BLK WHT RED GRN BLK WHT RED GRN BRN BLU BLK WHT RED GRN BRN BLU 1. SEE DETAIL 1, SHEET E -3 FOR ATS CABLE SCHEDULE 2. CONTRACTOR TO PROVIDE A NEW 66 BLOCK IF REQUIRED, WITH FURTHER ROUTING TO THE RBS EQUIPMENT CABINET AND LEFT WITH A 2' COIL OF WIRE. ALARM CABLING IN THE TELCO CABINET SHALL BE INSTALLED IN A NEAT FASHION WITH A 6" SERVICE COIL. CONTRACTOR SHALL NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 BLOCK WHT /BLU (UTILITY POWER) BLU /WHT WHT /ORG (GENERATOR POWER) ORG /WHT BLU /WHT WHT /ORG (ENGINE RUNNING) ORG /WHT WHT /GRN (<35% FUEL REMAINING) GRN /WHT WHT /BLU (GENERATOR MINOR) J WHT /GRN (TRANSFER SW POSTION) GRN /WHT WHT /BLU (GENERATOR FAILURE) BLU /WHT WHT /ORG .. ) (LEAK DETECTED) ORG /WHT ---� � 9 SOLID WIRE 7 SOLID WIRE 8 SOLID WIRE K WHT /BLU BLU /WHT WHT /BLU BLU /WHT WHT /ORG ORG /WHT WHT /GRN GRN /WHT WHT /ORG ORG /WHT WHT /GRN GRN /WHT K WHT /ORG K ORG /WHT K WHT /BLU BLU /WHT 43 18 44 19 45 20 22 48 23 49 24 50 25 36 11 37 12 38 13 39 14 40 15 41 16 L I L SCALE: (24 "X36 "): NOT TO SCALE SCALE: (1 1 "X17 "): NOT TO SCALE SYSTEM BLOCK 38 I 1 I I 43 18 44 19 J 45 L— J I 1 20 46 21 47 22 r 7 48 r .- - - - - -- I 7 L ' so_ USER BLOCK a G` 36 11 37 L___ 12 38 13 39 14 40 7 15 41 16 1 r - I L_— I I L - -_J L 11 37 12 17 23 49 24 50 25 MQ POWER ALARM WIRING - IDEN L j RECEIVED WY OF TUKWILP JUN f2 7001 :':EriM:T CENTER 1 N) S Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 Phone: (206) 342 - 9000 Fax: (206) 903 - 8513 THOMAS R. HOLLAND STATE OF WASHINGTON....' ELMO-SPAA 1 ] 030 EAST MARGINAL WAY S TUKWILA, WA 98 I 68 MQ POWER DIESEL GENERATOR ALARM WIRING — IDEN JOB # DRAWING # WA0233 E - 2 REVISION I o ALARM EXPANSION BOARD WEAK BATTERY LOW BATT VOLTAGE HIGH BATT VOLTAGE LOW ENGIN TEMP LEAK DETECT v1Q POWER DIESEL PADMOUNT GENERATOR SET REMOTE START 9 K5 10 11 K6 12 13 K7 14 15 K8 16 21 FAULT #1 22 23 FAULT #2 24 ENGINE RUNNING 25 FAULT #3 26 35% LOW FUEL 27 FAULT #4 28 29 FAULT #5 30 GENERATOR FAILURE 31 FAULT OUT #5 32 CONTROL PANEL NC NC NC NC C NC C NC NC C NC NC C NC RED BLK BLK WHT BRN BLU RED GRN RED GRN BRN BLU BLK WHT STRANDED WIRE STRANDED WIRE STRANDED WIRE NOTES: ASCO 7000 ATS /°- BRN L , 5 � BLU SOLID WIRE K K K BLK WHT RED GRN BLK WHT RED GRN BRN BLU BLK WHT RED GRN BRN BLU 1. SEE DETAIL 1, SHEET E -3 FOR ATS CABLE SCHEDULE 2. CONTRACTOR TO PROVIDE A NEW 66 BLOCK IF REQUIRED, WITH FURTHER ROUTING TO THE RBS EQUIPMENT CABINET AND LEFT WITH A 2' COIL OF WIRE. ALARM CABLING IN THE TELCO CABINET SHALL BE INSTALLED IN A NEAT FASHION WITH A 6" SERVICE COIL. CONTRACTOR SHALL NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 BLOCK WHT /BLU (UTILITY POWER) BLU /WHT WHT /ORG (GENERATOR POWER) ORG /WHT BLU /WHT WHT /ORG (ENGINE RUNNING) ORG /WHT WHT /GRN (<35% FUEL REMAINING) GRN /WHT WHT /BLU (GENERATOR MINOR) J WHT /GRN (TRANSFER SW POSTION) GRN /WHT WHT /BLU (GENERATOR FAILURE) BLU /WHT WHT /ORG .. ) (LEAK DETECTED) ORG /WHT ---� � 9 SOLID WIRE 7 SOLID WIRE 8 SOLID WIRE K WHT /BLU BLU /WHT WHT /BLU BLU /WHT WHT /ORG ORG /WHT WHT /GRN GRN /WHT WHT /ORG ORG /WHT WHT /GRN GRN /WHT K WHT /ORG K ORG /WHT K WHT /BLU BLU /WHT 43 18 44 19 45 20 22 48 23 49 24 50 25 36 11 37 12 38 13 39 14 40 15 41 16 L I L SCALE: (24 "X36 "): NOT TO SCALE SCALE: (1 1 "X17 "): NOT TO SCALE SYSTEM BLOCK 38 I 1 I I 43 18 44 19 J 45 L— J I 1 20 46 21 47 22 r 7 48 r .- - - - - -- I 7 L ' so_ USER BLOCK a G` 36 11 37 L___ 12 38 13 39 14 40 7 15 41 16 1 r - I L_— I I L - -_J L 11 37 12 17 23 49 24 50 25 MQ POWER ALARM WIRING - IDEN L j RECEIVED WY OF TUKWILP JUN f2 7001 :':EriM:T CENTER 1 N) S Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 Phone: (206) 342 - 9000 Fax: (206) 903 - 8513 THOMAS R. HOLLAND STATE OF WASHINGTON....' ELMO-SPAA 1 ] 030 EAST MARGINAL WAY S TUKWILA, WA 98 I 68 • N))1 r�t® "fr Together with NEXTEL REDMOND, RD E SUITE PHONE: 425.278.7400 i::::::) SEEEEE; PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 ;206) 342 -9000 Fa (206) 903 -8513 A x: POLYPHASER IX -6DC56 ARRESTOR SYSTEM BLOCK ` ■SCO 7000 SERIES TRANSFER SWITCH BLK 0 ± I-1-1 ± 0 I- IX o GND GND O 11 ■ , r 1 11 WHT /BLU 9 WHT /BLU �-- - ___-____ —T---- (UTIL1 SOLID POWER) WIRE (GENERATOR POWER) BLU WHT 37 I , I I I 37 0 O / 12 I I I I I 112 O ± I— ± GND u) GND 0 38 i 38 WHT BLU /WHT 0 O 1-1 21 11 i i i I 21 BLK 0 ± � H ± 0 cc o GND ( � GND a WHT /ORG RED WHT /ORG ORG J 47 47 ORG /WHT i I i 2 2r I 2 2 E 9 O O ` WHT /GRN UTILITY POWER J r i III 48 i 48 7) 6 0 ± w QC 0 GND GND Q ` GRN/WHT 23 1 1 r 1 I i 23 [OPTION 18G] (CLOSED WHEN WHT GRN BRN /WHT WHT /GRN la 111111 O O 49 —J �i � F -) 49 TIM 24 ' ' 24 POWER ON) / 7 0 ± w ca I— CY ° GND cn GND Q MI BLK , (_ GRN (TRANSFER SWITCH 50 1 I 1 , i 1 i J 50 4 O O 25 25 WHT , POSITION) MI A 1 N �� O 05 95 } ii Tx 700 WAYS I � c g c7) 00 Q± L ± CC O GND D CC GND Q 5 BLU STRANDED WIRE /WHT —I 0 O i / 3 9 GRN J J RED GENERATOR POWER `" ± w ± 0 [OPTION 188] (OPEN . WHEN POWER ON) GRN BLK / 0 ° ~ ii ' 1 0 GND D GND Q ' I ; ± ± RED - f WHT ) . 0 — 1= 0 GND : o GND (.) a__ 0 RED ± ± I. O CD I— O O f2C cc GND D GND v) a_ O ± f kl° 31 BLU ,- GRN Q L b \ / 0 GND D ° GND u) EL O 32 BRN TRANSFER SWITCH Z_ BRN ± ± POSITION (CLOSED FOR 0 a Q UTILITY) BLU 0 GND D ° GND cn 0_ O , 12 , I I ± ± BRN BLU 13 6 0 L L- O —� STRANDED GND ( GND WIRE O D u) 0- O CABLE NUMBER FROM TO v1ANUFACTURER PART NUMBER CONDUCTOR COUNT AND GAUGE USE dV HI HI 1 GENERATOR TERMINAL STRIP ATS BELDEN 8442 2 (UNSHIELDED) 22 AWG ATS GENERATOR START SIGNAL TO GENERATOR _ \ OT -S ; ND L-,-, L-,, 1. SECOND POLYPHASER IS PROVIDED FOR ENVIRONMENTAL CONTROL SYSTEM (TO BE CONNECTED BY OTHERS). 2. ALL POLYPHASERS SHALL BE MOUNTED W /IN THE EXISTING TELCO CABINET. IF THERE IS NOT SUFFICIENT ROOIv TO DO THIS, THE POLYPHASER(S) SHOULD BE MOUNTED W /IN A NEW 18 "X18 "X12" NEMA RATED ENLCOSURE MOUNTED ON THE EXISTING H — FRAME. 3. POLYPHASERS HAVE SPECIFIC WIRE IN /WIRE OUT ROUTING. THIS MUST BE FOLLOWED BY INSTALLATION PERSONNEL. 4. POLYPHASER QUANTITY REQUIREMENTS; —CDMA SITES RECEIVE 2, ONE MOUNTING PLANE FOR GENERATOR ALARMS ONLY. NO POLYPHASERS BETWEEN ATS AND BTS. —IDEN SITES RECEIVE 4, ONE MOUNTING PLANES, TWO FOR GENERATOR ALARMS, ONE FOR ATS ALARMS. —CO —HAB (IDEN AND CDMA) RECEIVE 4, ONE MOUNTING PLANE, ALL GENERATOR ALARMS GO TO THE IDEN SHELTER /CABINET, AND THE ATS ALARMS (FOR CDMA ONLY) DO NOT REQUIRE POLYPHASERS — STRAIGHT THROUGH TO BTS (RADIO CABINET). -- IN CO— HAB INSTANCES 2 ATS WILL BE USED. THE IDEN ATS USES POLYPHASERS BETWEEN IT AND FINAL PUNCHDOWN. 5. ALL ALARMS GO TO THE IDEN SIDE ON COHAB SITES. ATS ALARMS ALSO GO TO THE CDMA SIDE. NO POLYPHASERS ARE REQUIRED FOR THE ATS ALARMS FOR CDMA. eiG WOO WO8 2 GENERATOR TERMINAL STRIP SURGE ARRESTORS BELDEN 9421 8 (UNSHIELDED) 22 AWG GENERATOR A_ARMS TO SYSTEM BLOCK SURGE ARRESTOR REVISIO \S /0/6z/90 / 0/ /90 3 GENERATOR TERMINAL STRIP SURGE ARRESTORS BELDEN 8442 2 (UNSHIELDED) 22 AWG FUSED 12 VDC TO SYSTEM BLOCK SURGE ARRESTOR ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION 4 GENERATOR TERMINAL STRIP SURGE ARRESTORS BELDEN 9421 8 (UNSHIELDED) 22 AWG GENERATOR ALARMS TO SYSTEM BLOCK SURGE ARRESTOR 5 ATS SURGE ARRESTORS BELDEN 9421 8 (UNSHIELDED) 22 AWG ATS ALARMS TO SYSTEM BLOCK SURGE ARRESTOR 7 SURGE ARRESTORS TELCO BOARD SUPERIOR / ESSEX 12- 204 -37 8 (SOLID CONDUCTOR) 22 AWG GENERATOR A_ARM OUTPUTS FROM SYSTEM BLOCK SURGE ARRESTOR TO SYSTEM BLOCK Q ° 8 SURGE ARRESTORS TELCO BOARD SUPERIOR / ESSEX 12- 204 -37 8 (SOLID CONDUCTOR) 22 AWG GENERATOR ALARM OUTPUTS FROM SYSTEM BLOCK SURGE ARRESTOR TO SYSTEM BLOCK E 3 ATS CABLE SCHEDULE AND ATS ALARM WIRING - IDEN 9 SURGE ARRESTORS TELCO BOARD SUPERIOR / ESSEX 12- 204 -37 8 (SOLID CONDUCTOR) 22 AWG ATS A_,RM OUTPUTS FROM SYSTEM BLOCK SURGE ARRESTOR TO SYSTEM BLOCK RECEIVED ATS ALARM WIRING - IDEN 2 ATS CABLE SCHEDULE CtTYOFTUKWLA 1 JOB # DRAWING # SCALE: (24 "X36 "): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE JUN u SCALE: (24 "X36 "): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE ?& CENTS WA0233 E -3 REVISION I 0 ❑ V Hl I H± ELECTRICAL DETAILS JOB # DRAWING # WA0233 E - 4 REVISION I 0 NG W08 WO8 REVISIONS 05/29/07 Loll 1190 ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION Q o E 4 ELECTRICAL DETAILS JOB # DRAWING # WA0233 E - 4 REVISION I 0 NOTES: 1. POLYPHASER SURGE PROTECTORS SHALL BE MOUNTED NEAR THE ATS AND CONNECTED TO NEAREST GROUND WIRE EXITING THE SHELTER WITH A #6 WIRE WITH A TWO HOLE LUG CONNECTION. 2. 3. 4. ALL POLYPHASERS SHALL BE MOUNTED W /IN THE EXISTING TELCO CABINET. IF THERE IS NOT SUFFICIENT ROOM TO DO THIS, THE POLYPHASER(S) SHOULD BE MOUNTED W /IN A NEW 18 "X18"X12" NEMA RATED ENLCOSURE MOUNTED ON THE EXISTING H —FRAME POLYPHASERS HAVE SPECIFIC WIRE IN /WIRE OUT ROUTING. THIS MUST BE FOLLOWED BY INSTALLATION PERSONNEL. POLYPHASER QUANTITY REQUIREMENTS; — CDMA SITES RECEIVE 2, ONE MOUNTING PLANE FOR GENERATOR ALARMS ONLY. NO POLYPHASERS BETWEEN ATS AND BTS. —IDEN SITES RECEIVE 4, ONE MOUNTING PLANES, TWO FOR GENERATOR ALARMS, ONE FOR ATS ALARMS. — CO —HAB (IDEN AND COMA) RECEIVE 4, ONE MOUNTING PLANE, ALL GENERATOR ALARMS GO TO THE IDEN SHELTER /CABINET, AND THE ATS ALARMS (FOR CDMA ONLY) DO NOT REQUIRE POLYPHASERS — STRAIGHT THROUGH TO BTS (RADIO CABINET). -- IN CO—HAB INSTANCES 2 ATS WILL BE USED. THE IDEN ATS USES POLYPHASERS BETWEEN IT AND FINAL PUNCHDOWN. 5. ALL ALARMS GO TO THE IDEN SIDE ON COHAB SITES. ATS ALARMS ALSO GO TO THE CDMA SIDE. NO POLYPHASERS ARE REQUIRED FOR THE ATS ALARMS FOR L1 /L2 UTI LI CO. DISCONNECT CHASSIS (AND H— FRAME) BOND CHASSIS BOND N VUTILITY ELECTRICAL GROUND ROD* V3 INCHES ABOVE SURFACE FOR INSPECTION VEXOTHERIC BOND TO EXTERIOR GROUND RING VGENERATOR ELECTRICAL GROUND /EXOTHERMIC BOND TO EXTERIOR GROUND RING SHELTER DISCONNECT ATS /MTS N EMERGENCY° NORMAL VSHELTER ELECTRICAL GROUND ROD* V3 INCHES ABOVE SURFACE FOR INSPECTION Y'EXOTHERMIC BOND TO EXTERIOR GROUND RING *IF UTILITY DISCONNECT 15FT OR LESS FROM SHELTER, COMMON ROD PERMITTED, OTHERWISE, TWO DISTINCT RODS. * *BOND UTILITY DISCONNECT NEUTRAL /GROUND TO SHELTER GROUND IF UTILITY DISCONNECT IS WITHIN SHELTER PERIMETER, OTHERWISE, NOT BOND. NEUTRAL GROUND BOND SCALE: (24 "X36 "): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE CHASSIS BOND TO HALO (INTERIOR OR EXTERIOR (EXTERIOR) GENERATOR LOAD CENTER L1 /L2 CHASSIS BOND TO HALO 3 UTILITY DISCONNECT EMERGENCY POWER INPUT FROM PADMOUNT GENERATOR GENERATOR CHARGE CONNECTION ALARM / CONTROL CONNECTION APPLETON CONNECTOR GENERATOR G EN S ET/TAN K GROUND ROD I GENSET POWER OUT ALARM /STATUS /CONTROL TO GROUND RING L_ ALL GENSET CONNECTIONS VIA STUB —UP AREA CHARGER /HEATERS POWER ATS SURGE SUPPRESSOR SITE LOAD CENTER ATS* MULTI —PAIR A LOAD CENTER SCALE: (24 "X36 "): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE SITE POWER _ARM CABLE SCALE: (24 "X36 "): NOT TO SCALE SCALE: (1 1 "X 17 "): NOT TO SCALE V POWER SURGE PROTECTOR ALARM SURGE PROTECTORS NOTES: 1. IF PORTABLE IS REQUIRED IN ADDITION TO PADMOUNT GENERATOR, ADD PANNING AS REQUIRED TO ADD MANUAL TRANSFER SWITCH AND APPLETON CONNECTOR IN EMERGENCY BUS FROM ATS (SHOWN IN DOTTED LINES). GENSET SINGLE -LINE DIAGRAM UTILTY MAINS DISCONNECT ALARM 66 BLOCK CONDUIT SINGLE -LINE DIAGRAM TO FACILITY ALARM BLOCK (PROVIDED WITH SHELTER) TO SITE LOADS TO IMU UTILITY POWER IN 2 RECEIVED CITY OF TUKWILA JUN 1 '2 7007 ,'E T CENTER 1 )), Sprint Together with NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 PHONE: 425.278.7400 PACIFIC TELECOM SERVICES, LLC 568 First Avenue S., Suite 650 Seattle, WA. 98104 Phone: (206) 342 -9000 Fax: (206) 903 -8513 4072 THOMAS R. HOLLAND STATE OF WASHINGTON , A0233 / 310595 030 EAST MARGINAL WAY S TUKWILA, WA 98168