Loading...
HomeMy WebLinkAboutPermit D07-235 - VERIZON WIRELESS - ANTENNASVERIZON WIRELESS 18700 ORILLIA RD S EXPIRED 01 -05 -09 D07 -235 Parcel No.: 3523049037 Address: 18700 ORILLIA RD S TUKV/ Suite No: Tenant: Name: VERIZON WIRELESS Address: 18700 ORILLIA RD S , TUKWILA WA Owner: Name: KING COUNTY Address: 500 K C ADMIN BLDG , SEATTLE WA 98104 Phone: Contact Person: Name: JENNIFER TAYLOR Address: 14432 SE EASTGATE WAY SUITE 260 , BELLEVUE WA 98007 Phone: 425 - 274 -4444 EXT 141 Contractor: Name: BOSS CONSTRUCTION SERVICES LLC Address: PO BOX 251 , PACIFIC WA 998047 Phone: (253)863 -3881 Contractor License No: BOSSCSL981C2 DESCRIPTION OF WORK: RELOCATE VERIZONS ANTENNAS FROM THE MIDDLE PLATFORM TO THE TOP PLATFORM ON AN EXISTING MONOPOLE AT AN EXISTING WIRELESS FACILITY Value of Construction: $15,000.00 Type of Fire Protection: Type of Construction: doc: IBC-10 /06 City,.)f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:• / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D07 - 235 Issue Date: 07/13/2007 Permit Expires On: 01/09/2008 Expiration Date: 02/22/2008 Fees Collected: $518.28 International Building Code Edition: 2003 Occupancy per IBC: 0026 D07 -235 Printed: 07 -13 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: doc: IBC-10/06 City o.../Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Thee: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or e perfo ce of work. 1 am authorized to sign and obtain this development per mit. Signature: J�/tC/i1' - l ac/J/l Date: 7 1/3 k)7 Permit Number: D07 -235 Issue Date: 07/13/2007 Permit Expires On: 01/09/2008 Date: 1 3- V / � 7/ Print Name: C P 0 r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -235 Printed: 07 -13 -2007 Parcel No.: 3523049037 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 18700 ORILLIA RD S Timm VERIZON WIRELESS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: D07 -235 ISSUED 06/28/2007 07/13/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 D07 -235 Printed: 07 -13 -2007 Signature: Print Name: r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. 7 i Hill 1- et la kar Date: '7 /13107 doc: Cond - 10/06 007 -235 Printed: 07 -13 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION Site Address: 18700 Orillia Road S Tenant Name: Verizonn Wireless Property Owners Name: King County Mailing Address: 500 King County Administration Building Name: Jennifer Taylor - RealCom Associates Mailing Address: 14432 SE Fastgate Way Suite 260 E - Mail Address: ltaylor@realcomassoc.com Company Name: TRK Engineering Mailing Address: 17688 - 66th Avenue #201 Contact Person: Dennis Amantea E -Mail Address: mail( trkeng.com Q: Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. bo7- 2' Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 352304 - 9037 Bellevue City Suite Number: Seattle cit Surrey city New Tenant: Day Telephone: 425 - 274 -4444 ext. 141 WA State Floor: ❑ Yes I;1.. No CONTACT PERSON — who do we contact when your permit is ready to be issued Fax Number: 425 - 274 -4449 WA 98007 State GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: TBD Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State 98104 Z ip Z ip Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: N/A Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Day Telephone: 604 - 574 - 6432 Fax Number: 604 -574 -6431 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record BC, Canada V3S 7X1 State Zip Page 1 of 6 BUILDING PERMIT INFORTION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 15,000.00 Existing Building Valuation: $ N/A Scope of Work (please provide detailed information): Relocate Verizon's antennas from the middle platform to the top platform on an existing monopole at an existing wireless facility. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: No change Compact:No change Handicap: No change Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinlders ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x II " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: W pplicaiions\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh �.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2 Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORTION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 15,000.00 Existing Building Valuation: $ N/A Scope of Work (please provide detailed information): Relocate Verizon's antennas from the middle platform to the top platform on an existing monopole at an existing wireless facility. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: No change Compact:No change Handicap: No change Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinlders ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x II " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: W pplicaiions\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh �.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 Signature: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A)!ITHORJ / DAG T: Print Name. Jennifer Tayhr - R ea .gym Assoc. (Agent) Mailing Address: 14432 SE Fastpte Way Suite 260 Date Application Accepted: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: (e igaIMO Day Telephone: 425- 274 -4444 ext. 141 Bellevue WA 9g007 City State Zip Date Application Expires: a 9� 7 Staff Initials: 64 4 Page 6 of 6 Parcel No.: 3523049037 Permit Number: D07 -235 Address: 18700 ORILLIA RD S TUKW Status: PENDING Suite No: Applied Date: 06/28/2007 Applicant: QERIZON WIRELESS Issue Date: Receipt No.: R07 -01249 Initials: WER Payment Date: 06/28/2007 04:03 PM User ID: 1655 Balance: $0.00 Payee: REALCOM ASSOCIATES TRANSACTION LIST: Type Method Description Payment Check 7200 518.28 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Amount 311.38 202.40 4.50 Total: $518.28 Payment Amount: $518.28 9335 06/29 9716 TOTAL 518.28 doc: Recelot -06 Printed: 06-28 -2007 • Computer Structural Analysis on 60' Monopole for Site SEA Brisco, Tukwila, WA FILE COPY (TRK Project No. 0630 -020) (CSL Job #2007) -6 -39) iorza TRK Engineering Ltd. #201 17688 -66 Ave. Surrey, BC V3S 7X1 Canada June 21, 2007 by Chi S. Lee, P.E., S.E. 5801 Lorraine Ave. Sioux City, IA 51106 to Fax and Phone (712) 276 -2142 e -mail: chislee- pe @juno.com EXPIRES: 174, 09 RECEIVED JUN 2 = 8 2007 PERMIT CENTER 7- 235 CHI S. LEE, P. E., S. * * * Specializing in Communications Structure Design & Analysis * * * 5801 Lorraine Ave. Sioux City, IA 51106 FAX & Phone No. (712) 276 -2142 e -mail: chislee- pe @juno.com June 18, 2007 Dennis Amantea Project Manager TRK Engineering Ltd. #201 17688 -66 Ave. Surrey, BC V3S 7X1 Canada Re: 60' Monopole for Site: SEA Brisco, Tukwila, WA for Verizon Wireless (TRK Project No. 0630 -020) Dear Mr. Amantea, I have performed a structural analysis on an existing 60' Monopole (CSL Job #2007J- 6 -39), which is located at the SEA Brisco, Tukwila, WA site for Verizon Wireless. The existing 60' monopole was designed by Paul J. Ford and Company of Columbus, OH and fabricated by Summit Manufacturing, LLC of West Hazleton, PA in 1999. It is a tapered 18 -sided slip jointed type monopole. It consists of (2) sections with different wall thicknesses, diameters and lengths. All the monopole walls are made of 65 ksi steel materials. The existing monopole has a top diameter of 16.50" (across the flats) and a base diameter of 28.13" (across the flats). The details of the monopole sections, allowable capacities, forces and reactions, twists and sways, antenna loading and configuration of the monopole are shown on the printout of the computer structural analysis, which is a part of this report. The most updated information about the antenna loading and the existing monopole per Paul J. Ford and Company job #29299 -682 dated 1-3 -99 was furnished by your office. The office of Chi S. Lee, P.E., S.E. of Sioux City, IA did not visit the monopole site in Washington. The required basic design wind speed for Site: SEA Brisco, Tukwila, WA is 90 mph fastest -mile wind speed per the TIA/EIA- 222 -F -1996 Standard and 110 mph 3- second gust wind speed per the current International Building Code (IBC) and the Washington Building Code with 1/2" radial ice (with wind load reduction and 1/3 increase in allowable stresses taken). The existing antenna loading is as follows: (1) existing antenna platform at 57'-6" (2) 844G90VTA -SX and (2) LPA- 185090/4CF and (4) 7131.2.33.00 panel antennas mounted to an existing antenna platform with (8) 7/8" lines inside the monopole at 47'-6" (coax to be removed) (4) RR65 -19 -XXDP and (2) RR65 -18 -XXDP panel antennas mounted to an existing antenna platform with (12) 7/8" lines inside the monopole at 38' -0" (coax to be removed) The proposed antenna loading is as follows: (2) 844G90VTA -SX and (2) LPA- 185090/4CF and (4) 7131.2.33.00 panel antennas moved up to an existing antenna platform with (8) new 7 /8" lines inside the monopole at 57'-6" June 18, 2007 60' Monopole at Site #SEA Brisco, Tukwila, WA CSL Job #2007J -6 -39 Page 2 of 2 (4) RR65 -19 -XXDP and (2) RR65 -18 -XXDP panel antennas moved up to an existing antenna platform with (12) new 7/8" lines inside the monopole at 47'-6" (1) existing antenna platform at 38' -0" (to remain empty) Assuming the existing monopole is in good condition, the structural analysis shows that it is structurally adequate for supporting the proposed antenna loading at 90 mph fastest -mile wind speed per the TIAIEIA- 222 -F -1996 Standard and 110 mph 3- second gust wind speed per the current IBC and the Washington Building Code with 112" radial ice (with wind load reduction and 1/3 increase in allowable stresses taken) without any modifications. In this case, the most stressed point of the top monopole section occurs at El. 32' in which 25.6% of the allowable capacity of the existing section has been used. Also, the most stressed point of the bottom monopole section occurs at El. 0' in which 45.1% of the allowable capacity of the existing section has been used. According to my structural analysis dated 6 -15 -07, the maximum calculated base reactions of the existing 60' monopole are as follows: Total shear = 6.5 kips Axial download = 7.5 kips Overturning Moment = 277.0 ft -kips In accordance with Paul J. Ford and Company Job #29299 -682 dated 1 -3 -99, the maximum design base reactions are as follows: Total shear = 12.0 kips Axial download = 8.0 kips Overturning Moment = 575.0 ft-kips Since my updated base reactions are less than those base reactions designed by Paul J. Ford and Company in 1999, the existing anchor bolts, base plate and caisson foundation are structurally safe. Meanwhile, wind Toad, not seismic load, governs both the monopole and foundation designs. This structural analysis is only good for the wind speed, antenna loading and configuration of the monopole as described above. If there are any changes made by any party without my notice or reanalysis of the monopole, then Chi S. Lee, P.E., S.E. is not responsible for the structural integrity of the monopole or any damage caused by the monopole failure. If you have any questions, please feel free to contact me. Sincerely, Chi S. Lee, P.E., S.E. Washington P.E. Reg. No. 29475 I EXPIRES: 7— to - D CHI S. LEE, P S * * * Specializing in Communications Structure Design & Analysis * * * 5801 Lorraine Ave. Sioux City, IA 51106 FAX & Phone No. (712) 276 -2142 e -mail: chislee- pe @juno.com DESCRIPTION OF MONOPOLE COMPUTER PROGRAM A monopole computer program using the stiffness matrix (finite element) method has been developed by Chi S. Lee, P.E. to perform the structural analysis and design of either slip - jointed (tapered) polygonal monopoles or stepped poles (straight pipes with flange plates and splice bolts). The general principle of analysis of a monopole is based on the papers published in the ASCE Journal of the Structural Division such as No.'s 3021, 3375 and 4671. The stiffness matrix method is based on the articles published in the ASCE's Fall Convention and Exhibit held in San Francisco, CA in October of 1977 and ASCE's 8th Conference of Electronic Computation in Houston, TX in February of 1983. However, the boundary conditions of a global matrix of a monopole is slightly different than that of a guyed tower. The other reference books for stiffness matrix or finite element method are Richard H. Gallagher, Finite Element Analysis Fundamentals, Prentice -Hall, Inc., Englewood Cliffs, N.J., 1975; William Weaver, Jr. & Paul R. Johnston, Finite Elements for Structural Analysis Prentice -Hall, Inc., 1984 and M. B. Kanchi, Matrix Methods of Structural Analysis, John Wiley & Sons, New York, N.Y., 1981. The basic criteria of designing a monopole such as wind speed, effective areas of monopole sections, allowable stresses, allowable rigidity and foundations are based on the updated ANSI/EIA/TIA Standards. Basically, a monopole is treated as a cantilever beam. Wind, ice and weight are the major design loads considered in the static analysis. Effects due to torques, axial loads, slopes, deflections and secondary moments (P - A effect) are included in the monopole program. After all the necessary input data is entered, the program will compute the wind loads at different elevations together with the effective area and the allowable capacity of each monopole section. Then it will generate a stiffness matrix of each individual monopole section. Then the matrices are assembled to form a global matrix. A system of linear simultaneous equations is set based upon the equilibrium conditions of the global matrix, deformations and load vector. By solving the equations and then by back substitution of the deformations into individual elements (monopole sections), the final axial forces, end shears and end moments are obtained. Then the shear, axial down force, moment and the combined stress ratios at the bottom of each monopole section are calculated. For clarity and simplicity, the monopole program only prints out the maximum reactions and loads of monopole sections due to the different directions of wind acting at a monopole. The base reactions of a monopole are for the purposes of foundation design. BASIC language is employed for programming and the program can be executed by a personal computer. MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 1 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe@juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** MONOPOLE * * * ** MONOPOLE HEIGHT (ft.) WIND SPEED (mph) RADIAL ICE (in.) 60 55 57.5 1.172 55 50 52.5 1.142 50 45 47.5 1.110 45 40 42.5 1.075 40 36 38.0 1.041 36 32 34.0 1.009 32 25 28.5 1.000 25 20 22.5 1.000 20 15 17.5 1.000 15 10 12.5 1.000 10 5 7.5 1.000 5 0 2.5 1.000 = 60 = 90 = 0 TAPER OF POLE (in. /ft.) = .2 CROSS SECTION (SHAPE) OF POLE = 18 -SIDED DIAMETER OF THE TOP OF POLE (in.) = 16.5 GUST RESPONSE FACTOR FOR THE POLE, Gh = 1.69 No. OF WIND PRESSURE LEVEL(S) = 12 FROM TO z Kz Qz Qz *Gh ft ft ft psf psf 24.30 41 23.68 40 23.01 39 22.29 38 21.59 36 20.91 35 20.74 35 20.74 35 20.74 35 20.74 35 20.74 35 20.74 35 'EXPIRES: q b D9 I MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 2 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe@juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** ANTENNA LOADING DATA * * * ** ELEV. PROJECTED WIND DEAD DESCRIPTION AREA LOAD LOAD OF ft. sq. ft. kips kips LOADING 58 47.00 1.94 0.95 (8) PANLES + PLATFORM 48 36.00 1.40 0.85 (6) PANELS + PLATFORM 38 14.00 0.51 0.65 EMPTY PLATFORM MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 3 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe@juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** UNIFORM LOADING * * * ** FROM TO PROJECTED DEAD DESCRIPTION AREA LOAD OF (ft) (ft) (sq. ft /ft) (k /ft) LOADING 58 0 0.00 0.008 NEW (8) 7/8 LINES 48 0 0.00 0.012 NEW (12) 7/8 LINES MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 4 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe @juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** MONOPOLE DATA * * * ** DIAMETER OF THE TOP = 16.5 in. AND NOMINAL DIAMETER OF THE BOTTOM = 28.50 in. ELEVATION AVG. WALL w/t STEEL CROSS SECTION MOMENT OF YIELD FROM TO O.D. THK. OR WT. AREA MODULUS INERTIA STRESS ft ft in. in. OD /t lb /ft in ^ 2 in *3 in *4 ksi 60 55 17.0 0.188 15.7 32.6 9.6 38.9 316.3 65.00 55 50 18.0 0.188 16.7 34.6 10.2 43.8 378.1 65.00 50 45 19.0 0.188 17.6 36.6 10.7 49.0 447.5 65.00 45 40 20.0 0.188 18.5 38.6 11.3 54.5 524.9 65.00 40 36 20.9 0.188 19.4 40.6 11.9 60.3 610.7 65.00 36 32 21.7 0.250 15.1 56.0 16.5 86.4 906.2 65.00 32 25 22.8 0.250 15.8 58.2 17.1 93.1 1013.5 65.00 25 20 24.0 0.250 16.7 61.9 18.2 105.4 1221.1 65.00 20 15 25.0 0.250 17.4 64.6 19.0 114.6 1385.5 65.00 15 10 26.0 0.250 18.1 67.2 19.8 124.3 1564.1 65.00 10 5 27.0 0.250 18.8 69.9 20.5 134.3 1757.4 65.00 5 0 28.0 0.250 19.4 72.5 21.3 144.8 1965.9 65.00 MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 5 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe@juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** MONOPOLE AND LOADING DATA * * * ** NOTES:- (1) LINEAR ATTACHMENT IS ADDED TO THE MONOPOLE (2) DEAD LOAD INCLUDES ICE, IF ANY ELEVATION AVG. FORCE UNIFORM UNIFORM ANTENNA TORQUE TOP BOTTOM O.D. COEFFICIENT WIND LOAD DEAD LOAD DEAD LOAD ft. ft. in. Cf k /ft k /ft kips ft -k 60 55 17.00 0.650 0.038 0.041 0.95 0.00 55 50 18.00 0.650 0.039 0.043 0.00 0.00 50 45 19.00 0.650 0.040 0.057 0.85 0.00 45 40 20.00 0.650 0.041 0.059 0.00 0.00 40 36 20.90 0.650 0.041 0.061 0.65 0.00 36 32 21.70 0.650 0.042 0.076 0.00 0.00 32 25 22.80 0.650 0.043 0.078 0.00 0.00 25 20 24.00 0.650 0.046 0.082 0.00 0.00 20 15 25.00 0.650 0.047 0.085 0.00 0.00 15 10 26.00 0.650 0.049 0.087 0.00 0.00 10 5 27.00 0.650 0.051 0.090 0.00 0.00 5 0 28.00 0.650 0.053 0.093 0.00 0.00 MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 6 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe @juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** RESULTS OF ANALYSIS * * * ** ELEVATION BENDING MOMENT OF LATERAL SLPOE ACCUM'D FROM TO MOMENT INERTIA DEFLECTION OR SWAY TWIST ft ft ft -K in *4 ft. deg. deg 60 55 6.28 316.3 1.012 1.578 0.000 55 50 17.39 378.1 0.875 1.563 0.000 50 45 33.69 447.5 0.740 1.519 0.000 45 40 53.82 524.9 0.610 1.438 0.000 40 36 71.68 610.7 0.490 1.319 0.000 36 32 91.23 906.2 0.402 1.202 0.000 32 25 127.08 1013.5 0.321 1.100 0.000 25 20 154.01 1221.1 0.199 0.885 0.000 20 15 182.10 1385.5 0.129 0.722 0.000 15 10 211.41 1564.1 0.073 0.549 0.000 10 5 241.97 1757.4 0.033 0.370 0.000 5 0 273.84 1965.9 0.008 0.187 0.000 MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 7 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe@juno.com 60' MONOPOLE, TUKWILA, WA (##2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** RESULTS OF ANALYSIS * * * ** SPAN WIND MAIN BENDING SECONDARY COMBINED AXIAL ELEV SHEAR MOMENT MOMENT MOMENT LOAD ft. kips ft -k ft -k ft -k kips 55 2.12 6.28 0.16 6.44 1.15 50 2.32 17.39 0.34 17.73 1.37 45 3.92 33.69 0.67 34.36 2.50 40 4.13 53.82 1.00 54.82 2.79 36 4.80 71.68 1.33 73.01 3.68 32 4.97 91.23 1.65 92.88 3.99 25 5.27 127.08 2.20 129.28 4.53 20 5.50 154.01 2.55 156.56 4.94 15 5.74 182.10 2.85 184.95 5.37 10 5.98 211.41 3.08 214.49 5.80 5 6.24 241.97 3.23 245.21 6.25 0 6.51 273.84 3.29 277.13 6.72 MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 8 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe @juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** RESULTS OF ANALYSIS * * * ** SPAN SECTION BENDING CROSS AXIAL COMBINED ALLOW. COMBINED ELEV MODULUS STRESS -AREA STRESS STRESS STRESS STRESS ft. in *3 ksi in *2 ksi ksi ksi RATIO 55 38.9 1.98 9.57 0.12 2.11 39.00 0.05 50 43.8 4.85 10.16 0.13 4.99 39.00 0.13 45 49.0 8.41 10.75 0.23 8.64 39.00 0.22 40 54.5 12.06 11.33 0.25 12.31 39.00 0.32 36 60.3 14.52 11.92 0.31 14.83 39.00 0.38 32 86.4 12.90 16.47 0.24 13.14 39.00 0.34 25 93.1 16.67 17.10 0.27 16.93 39.00 0.43 20 105.4 17.83 18.19 0.27 18.10 39.00 0.46 15 114.6 19.36 18.97 0.28 19.64 39.00 0.50 10 124.3 20.71 19.76 0.29 21.00 39.00 0.54 5 134.3 21.90 20.54 0.30 22.21 39.00 0.57 0 144.8 22.97 21.32 0.31 23.29 39.00 0.60 MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 9 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe @juno.com 60' MONOPOLE, TUKWILA, WA (##2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * * * ** BASE REACTIONS * * * ** TOTAL TOTAL OVERTURNING ESTIMATED SHEAR DOWN LOAD MOMENT STEEL WEIGHT kips kips ft -kips kips 6.51 7.52 277.13 3.99 MONOPOLE ANALYSIS & DESIGN BY CHI S. LEE, P.E., S.E. Page 10 5801 LORRAINE AVE., SIOUX CITY, IA 51106. FAX /PHONE NO. (712) 276 -2142 E -MAIL: chislee- pe@juno.com 60' MONOPOLE, TUKWILA, WA ( #2007J -6 -39) 6 -15 -07 90 MPH WIND + 0.5 in. RADIAL ICE (WITH REDCTION) PER EIA- 222 -F -1996 FEEDLINES ARE INSIDE THE POLE DATA FILE LEEMP -F \076- 39.DAT * ** DETAILED DIMENSIONS OF THE MONOPOLE * ** ELEV. SPAN SPLICE SPLICE WALL TOP BOTTOM SPAN ACCUMULATED LENGTH LENGTH + SPAN THK. O.D. O.D. WT. POLE WT. ft. ft. ft. ft. in. in. in. kips kips 60.0 28.0 0.0 28.0 0.188 16.5 22.1 1.07 32.0 32.0 3.0 35.0 0.250 21.1 28.1 2.28 SUM OF NET SPAN LENGTHS = 60 WT. OF TOP PLATE WITH 18.5 in. DIAMETER X 1 in. = 0.076 KIPS WT. OF BASE PLATE WITH 40.5 in. DIAMETER X 2.25 in. = 0.567 KIPS TOTAL WT. OF POLE WALLS AND PLATES = 3.99 KIPS POLE HT. = 60 TAPER = .2 in. /ft. 1.07 3.35 12 -03 -2008 JENNIFER TAYLOR 14432 SE EASTGATE WAY SUITE 260 BELLEVUE WA 98007 RE: Permit No. D07 -235 18700 ORILLIA RD S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 01/05/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall, t Technician Permit File No. D07 -235 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 July 22, 2008 Olivia Bazylewicz RealCom Associates LLC 14432 E Eastgate Way, Ste 260 Bellevue WA 98007 RE: Request for Extension #2 Development Permit No. D07 -235 Verizon Wireless —18700 Orillia Rd S Dear Ms. Bazylewicz, This letter is in response to your written request for an extension to Permit No. D07 -235. The Acting Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending the expiration date of your permit an additional 180 days, through January 5, 2009. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. D07 -235 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director jem ,arkc)ridtk hall cian P:\Permit Center\Extension Letters \Pernuts\2007\D07 -235 Permit Extension#2.doc Page 1 of 1 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 From: July 1, 2008 City of Tukwila - Department of Community Development 6300 South center Boulevard, Suite #100 Tukwila, WA 98188 RE: Development Permit No. D07.235, site located at 18700 Orillia Road S, TUKW Dear Building Official, Please accept this letter as Verizon Wireless's request to extend Permit Number D07-235. Antenna Equipment is still on order. Once all equipment is received construction will begin. If you have questions or concerns, please contact Olivia Bazylewicz at the RcalCom office at 425 - 274 -4444 ext.118 or by email at obaz @realcomassoc.com. Thank you, • Olivia Bazylewicz RealCom Associates LLC 14432 SE Eastgate Way, Ste. 260 Bellevue, WA 98007 R E bika /rcialf 1/.6 e90f/e6 !` . L C O M 07/11/2008 14 ;00 #328 P.002/003 R ECELVED JUL 112008 PERMIT CENTER 6/6f n-toolk 66 17 oil REALCOM Associates, LLC • 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 • p 425- 274-4444 f 425.274.4449 Re CE 1 V ED 3 2008 revELO July 1, 2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 RE: Development Permit D07 - 403, site located at 18800 Orillia Rd S Tukwilla Dear Building Official, REY LCOM Please accept this letter as Verizon Wireless's request to extend Permit Number D07 - 403. The antenna equipment has not yet arrived. Once equipment is available construction will begin. Verizon Wireless requests a six month extension of the Building Permit. If you have questions or concerns, please contact Olivia Bazylewicz at the RealCom office at 425- 274 -4444 ext.118 or by email at obaz @realcomassoc.com. Than p Olivia Bazylewicz RealCom Associates LLC 14432 SE Eastgate Way, Ste. 260 Bellevue, WA 98007 REALCOM Associates, LLC • 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 • p 425 - 274 -4444 f 425 - 274 -4449 October 31, 2007 Olivia Bazylewicz RealCom Associates LLC 14432 E Eastgate Way, Ste 260 Bellevue WA 98007 RE: Request for Extension Development Permit No. D07 -235 Verizon Wireless —18700 Orillia Rd S Dear Ms. Bazylewicz, This letter is in response to your written request for an extension to Permit No. D07 -235. The Acting Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending the expiration date of your permit an additional 180 days, through July 09, 2008. If you should have any questions, please contact our office at (206) 431 -3670. File: Permit No. D07 -235 Department of Community Development Steve Lancaster, Director jem City of Tukwila P:\Pennit CenterExtension Letters \Pennits\2007\D07 -235 Permit Extension -doe Page 1 of 1 Steven M Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 October 25, 2007 RE Bob Benedicto City of Tukwila - Department of Community Development 6300 South center Boulevard, Suite #100 Tukwila, WA 98188 RE: Development Permit No. D07 -235, site located at 18700 Orillia Road S, Tukwila WA, Parcel No. 3523049037. Dear Building Official, Please accept this letter as Verizon Wireless's request to extend Permit Number D07 -235. In July 2007 the City of Tukwila issued a Building Permit to relocate antennas. The agreement to proceed with Modifications to this site is still in process. No work can begin until agreement is fully executed by both parties. Verizon Wireless requests a six month extension of the Building Permit so work can begin and allow the project to move forward. If you have questions or concerns, please contact Olivia Bazylewicz at the RealCom office at 425- 274 -4444 ext.118 or by email at obaz @realcomassoc.com. Thank you, Olivia Bazylewicz RealCom Associates LLC 14432 SE Eastgate Way, Ste. 260 Bellevue, WA 98007 Vre 54 /00 day5 it 3i-07 RECEIVED 10CT1 9 2001 COMMUNITY DEVELOPMENT REALCOM Associates, LLC • 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 • p 425 - 274 -4444 f 425 - 274 -4449 06 -05 -2008 JENNIFER TAYLOR 14432 SE EASTGATE WAY SUITE 260 BELLEVUE WA 98007 RE: Permit No. D07 -235 18700 ORILLIA RD S TUKW Dear Permit Holder: City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/09/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 1.4 ISO er Marshall, Permit Technician xc: Permit File No. D07 -235 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS� •' n Bu c n i g Division Complete TUESJTHURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 ;‘;;',4 l OORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -235 DATE: 06 -29 -07 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 18700 ORILLIA RD S X Original Plan Submittal Response to Correction Letter Response to Incomplete Letter # Revision # After Permit Issued APPROVALS OR CORRECTIONS: Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Structural ❑ Permit Coordinator Incomplete Structural Review Required / ')40 Planning Division DUE DATE: 07 -3-07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: Notation: REVIEWER'S INITIALS: DATE: El DUE DATE: 07 -31 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License BOSSCSL981C2 Licensee Name BOSS CONSTRUCTION SERVICES LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602178221 Ind. Ins. Account Id #1 Business Type LIMITED LIABILITY COMPANY Address 1 PO BOX 251 Address 2 City PACIFIC County KING State WA Zip 98047 Phone 2538633881 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/22/2002 Expiration Date 2/22/2008 Suspend Date Separation Date Parent Company Previous License BOSSCS•006JK Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 DEVELOPERS SURETY & INDEM CO 857070C 02/20/2002 Until Cancelled $12,000.00 02/22/2002 Business Owner Information Name Role Effective Date Expiration Date BRENDEN, MICHAEL T PARTNER/MEMBER 02/22/2002 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= BOSSCSL981 C2 07/13/2007 DRAWING INDEX D N G L. DESCRIPTION N R O T -I COVER SWEET I A -I SPECIFICATIONS I A -2 SITE PLAN 1 A -3 COMPOUND LAYOUT 1 A -4 EXISTING EAST ELEVATION A -5 PROPOSED EAST ELEVATION A -6 PROPOSED WEST ELEVATION I A -1 PROPOSED NORTH AND SOUTH ELEVATIONS E -1 GROUNDING DETAILS RENEWED F N C ODE COM A ppROV AIL . 0 200 • t Cfil Of Tukw • B 01 DM I•N Pan rev FILE iew No. • . "_view a rova. S subject W e a a , 4 � : k tf' a violation el ePPTNet 1 me doe not - • • cf construction documents • accepted d code or ea F _•:.iF Fir d Copy Rid moons is adm _' .::. F' - Date: _1( 1 10 City of lbkwila BUILDING DIVISION SEPARATE PERIM? REQUIRED FOR: efmedonical le Vinumbing IllfGaa Piping City of Tukwila ru rime. r vre rr".. a1... R z`d1=PROVAL LIST 1,4 TITLE SIGNATURE DATE RF ENGI4EER PROJECT MANAGER SITE ACQUISITION ZONING CONTACT PROPERTY OWNER very PROJECT SUMMARY SITE NAME: SITE ADDRESS: ASSESSOR'S PARCEL •: CURRENT ZONNG: GOVERNING CODE: JURISDICTION: CONSTRUCTION TYPE: OCCUPANCY: PROPERTY OWNER: SITE ACQUISITION: ZONING CONTACT: PROJECT MANAGER: CONSTRUCTION MANAGER: APPLICANT: CONSULTANT: SURVEYOR: POWER: TELCO: PREVIOUS PERMIT APPROVALS: 011 wireless SEA BRISCO ANTENNA MODIFICATION SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA 352304 -9031 TUKWILA VALLEY SOUTH (TVS) IBC 2003 CITY OF TUKWILA N/A N/A KING COUNTY 500 KING COUNTY ADMINISTRATION BUILDING SEATTLE, WA 58104 JULEI HINTY PHONE: (425) 214 -4444 (EXT. 128) SARAH TELSCHOW 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE,WA 58001 PHONE: (425) 214 -4444 (EXT. 114) EMAIL: 6te15chow Brea (coma ssec.com JULEI HINTY PHONE: (425) 214 -4444 (EXT. 128) CHRISTOPHER STEPHENS PHONE: (425) 603 -2725 vERIZON WIRELESS TRIG ENGINEERING LTD •201 - 11685 - 66T1-1 AVE SURREY, BC V35 1X1, CANADA CONTACT: DENNIS AMANTEA TEL: (604) 514 -6432 FAX: (604 514 -6431 TOLL FREE: 1-811-345-4045 EMAIL: MAILeTRKENG.COM N/A T.D. TBD. MI99 -0221 MI99 -0203 PROJECT DESCRIPTION - ROTATE EXISTING TOP ANTENNA PLATFORM .RELOCATE (8) EXISTING ANTENNAS FROM MIDDLE PLATFORM TO �j Eb ISTING TOP ANTENNA PLATFORM - t�f2Et1OVE EXISTING 1/8" ANTENNA CABLES AT THE 41' -6" PLATFORM AND 1' 'REPLACE WITH 1/8" ANTENNA CABLES UP TO THE 51' -6" PLATFORM E). - tiRFS 11/06/ 7 JUN 2 7 no 5 �1 5 192ND 5T 5 192ND LN 5 188TH ST KEY PLAN N.T.S. 5 154TH ST VERIZON WIRELESS SITE NAVD 88: GROUND ELEV.. T.BD. TRANSFER STATION ACC °55 ROOD NAD 83 LAT. 41' 26' 0.1 N LONG. 122' 16' I05 W DIRECTIONS FROM BELLEVUE TAKE 1 -405 (SOUTH). ROAD NAME CHANGES TO SR -518. TAKE RAMP (RIGHT) ONTO 1 -5 (TOWARDS 1 -5 / PORTLAND). AT EXIT 152, TURN RIGHT ONTO RAMP (SOUTH 188T1-1 STREET / ORILLIA ROAD). KEEP LEFT TO STAY ON RAMP TOWARDS ORILLIA ROAD. TURN LEFT (SOUTH -EAST) ONTO SOUTH 188TH STREET. TURN LEFT (NORTH) ONTO ORILLIA ROAD SOUTH. ARRIVE AT 18100 ORILLIA ROAD SOUTH (TRANSFER STATION) SITE 15 PAST TRANSFER STATION TOOL 500T1-1 ON LEFT SIDE. No Cf t,rrFiC N _ H to Me ���� NOM Revisions wM and m:y Include ad uona plan .�review fees.ttal ve. w a w wireless RE*'LCOM K ENGINEERING 401 - 11656 - 66T14 AVE SURREY, DC V35 1X1, CANADA TEL, (604) 514 -6431 FAX (604) 514 -6431 TOLL FREE, I -611 -345 -4045 EMAIL, Ra4I.Vkengcon WED: alawArkanscom PROJECT No. 0630 - me 'DRAW DT, cut I CJEOCE - D DT, 5M CID FILE. 0630 -03011 SUBMITTALS 5 • Jw 2601 nrot FED 1b01 JAN 25101 GENERAL REV16OG N MEWED FOR Dp.CO ET. 6510 . REVI5IOIS MEMO FOR REVIEW THE INFORMATION CONTAINED M 5H15 5E1 OF 00 10305 15 PROPRIETARY DY NATURE ANY IDE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMED 15 STRICTLY PROWIDITED. ASE SEAL RECEIVED JUN 2.8 2007 PERMIT CENTER 5115 SEA BRISCO 15700 ORILLIA RD 5 TUKWILA, WA SHEET TITLE COVER SHEET SHEET NUMBER T -1 GENERAL NOTES: t THE PROPOSED INSTALLATION WILL BE tN'7AN.ED AND DOES NOT REQUIRE POTABLE WATER OR SELLER SERVICE. 2. TAE PROPOSED INSTALLATION IS LN'7A•lED AND IS NOT FOR FLTTAN HABITATION (NO HANDICAP ACCESS 15 REOUIREDA 3. OCCUPANCY IS LSITED TO PERIODIC MAINTENANCE AND NSPECTON APPROXIMATELY 2 TIMES PER MONTH, B7 VERIZON WIRELESS TECHNICIANS. 4. NO NOISE, SMOKE, DUST OR ODOR LULL RESULT FROM 71.415 PROPOSAL. 5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. 6. ALL REFERENCES TO SPECIFIC STANDARDS FOR 11415 PROPOSAL A1 ZF UNDERSTOOD TO DE THE LATEST VERSION. 1. THE TENDERER 19157 UNDERGO A SITE vISIT TO CAREFULLY EXAMINE AND UDER5T41.0 1445 SCORE OF THE WORK REQUI DEF055 510 SUBMISSION. NO COMPENSATION N ANY FORM WILL BE PAID FOR EXPENSES 1 FROM FAILURE TO DO 50. 8. F 744E SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON 74455E DRAWINGS, THE CONTRACTOR 5444LL PROPOSE AN ALTERN4TIvE NSTALL4TION FOR APPROVAL BY THE CONSTRUCTION MANAGER 9 CONTRACTOR 15 R FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS, ELECTRICAL LINES, AND ANTENNA CABLES. 10. ROVING OF ALL CONDUITS, CABLES. CABLE TRAY, ETC. 15 INDICATED AS PROPOSED LOCATIONS ONLY. CONFIRM THE EXACT ROUTING WITH THE ON -SITE CONSTRUCTION MANAGER PRIOR TO THE START OF WORK It ALL DAMAGE OR OPENING UP OF 1445 EXISTING STRUCTURE MUST DE MADE GOOD TO THE PRE - CONSTRUCTION CONDITION OR BETTER 0. NSPECTION CF COMPLETED WORK IS REQUIRED DEFORE COVERING UP. PROVIDE MNMI111 24 HOURS NOTICE TO CONSULTANT. D. REMOVE AND CLEAN UP ANY DEDRIS OR MATERIAL FROM THE SITE THROUGI4CUT THE DURATION OF TE CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY 7445 CONSTRUCTION MANAGER 14. OBTAN AND PAY FOR ALL ELECTRICAL P551115 MID INSPECTIONS REQUIRED FOR COMPLETION OF WORK MUD ACCEPTANCE PROVIDE CERTIFICATES TO 714E CONSTRUCTION MANAGER VERIFYING THAT 714E WOW CO FOR19 70 THE REQUIREMENTS OF ALL CODES AD AUTHORITIES HAVING AM501071 N. 5. PROVIDE VERIZON WIRELESS 141114 A WRITTEN WARRANTY, EFFECTIVE FOR CNE YEAR AFTER DATE OF ACCEPTANCE, FOR 745 COMPLETE INSTALLAT ION. REPAIR OR REPLACE ANY DEFECTS ARISING DURING 71415 PERIOD AT NO EXTRA COST TO VERIZON WIRELESS. 16. NO DEVIATIONS FROM DESIGN 5140114 ON 14455E DRAWINGS IS ALLOWED, WITHOUT WRITTEN APPROVAL FROM 744E CONSULTANT. FAILU E TO OBSERVE 74.415 RULE MAY RESULT IN CONTRACTOR CORRECTING 114E INSTALLATION AT THEIR EXPENSE II. ALL ITC'k NOT LISTED AS ID41815440 OR ''RONDED DY WHEW ARE TO DE SUPPLIED AND INSTATED 57 THE CONTRACTOR IS, STRUCTURAL ANALYSIS TO VERIFY TN4T EXISTING STRUCTURE 14A6 CAPACITY TO SIINTORT PROPOSED ANTENNA LOADINS MUS7 DE DOE 1157 A PROFESSIONAL MINCER PRIOR TO CANSTR1CTKa1 PRIOR TO CONSTRICTICEL CONTRACTOR TO OBTAN COPY Cr T416 ANALYSIS AND 6015151 154AT LOADERS N ANALYSIS MATC4E6 PROPOSED LOADING N DRAWINGS, REPORT ANY DISCREPANCIES TO ENGINEER. DESIGN CRITERIA: L 714E STRUCTURAL DESIGN CF T1415 INSTALLATION 15 M ACCORDANCE WITH IBC 7003. 2. P55I91 LOADS1 05540NN DATA FOR noaum.A. WA. • GROUND 5NCIU LOAD 25 p.f • D4SIC WIND SPEED (3 5E0 GUST). 85 mph • WIND EXPOSUT C • SEISMIC DESIGN CATEGORY 02 • MAPPED SPECTRAL ACCELERATIONS FOR SHORT PERIODS 55 • 13110 g • MAPPED SPECTRAL ACCELERATIONS FOR A I SECOND PERIOD 51 • 0.4515 5 4 SLABS ON GRADE TOPING SLABS CONCRETE PIERS CONCRETE NOTES: L ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH 401 -318. 2. CONCRETE 54441.1. BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBC 7003 SECTION 1905 AND ACI 301. 5TRENG7145 AT 28 DAYS AND MIX CRITERIA SHALL BE 45 FOLLOWS. 3. TYPE CP CONSTRUCTION 25 DAY STRENGTHS W/0 MINIMUM CEMENT (re) RATIO CONTENT PER CUBIC YARD 3000 PSI $ .45 5 IR BACK 5. ALL STRUCTURAL CONC51E 4000 PSI C. FOUNDATIONS 3000 P51 $ .45 6 IR SACKS $ .45 5 in 54055 CEMENT SHALL BE 45141 050. PORTLAND CEMENT TYPE II LINO. 4. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DE 2 FOR 7445 METHODS AND PR00501) E 5 OF CONC PLACEMENT. 5. ALL CONC WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR- ENTR4NED WITH AN AIR - ENTRAINING AGENT CONFORMING TO 45T11 C760, 0494, 0618, C985 AND CI011. TOTAL AIR CONTENT SHALL BE N ACCORDANCE WITH TABLES 19043) OF THE IBC 2003. 6. IZINFORCNG STEEL SHALL CONFORM TO A5TM 466 (NCLUDNG SUPPLEMENT 5U, GRADE 60 f •60000 P51. EXCEPTIONS. ANY BARS SPECIFICALLY SO NOTED ON THE DRAWRG5 SHALL BE GRADE 40. 54•40000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO DE WELDED SHALL CONFORM TO 45TH 4106. WITFORCING COMPL7NG WITH 45151 4615(54) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES 5PECFIED IN A1119. 014 ARE SUBMITTED. 1. I/ INFORGNG STEEL SHALL BE DETAILED (INCLUDING 440055 AND BENDS) IN ACCORDANCE W1744 ACI 35 AND 318. LAP ALL CONTINUOUS REINFORCEMENT AT LEAST 30 DAR DIAMETERS OR A MINIMUM OF 7' -0'. PROVIDE CORNER EARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORER DAR5 AT LEAST 30 DAR DIAMETERS OR A MNMU1 OF 7' -0•. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MIN11111 OF 6 SIDES AND ENDS. S. WELDED WIRE FABRIC SHALL CONFORM TO A5TM A -I55. 9. SPIRAL REINFORCEMENT SHALL BE PLAN LURE CONFORMING TO 45711 A65, GRADE 60, f•60000 P6L 10. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY 50 DETAILED OR APPROVED BY 744E CONSULTANT. 11 CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS. • FOOTNG5 AND OTHER WFOR55ED 3' SU/WAGES, 545114 FACE •FORMED SURFACES EXPOSED ('6 BARS OR 14FYGER/ 7 TO EARTH OR WEATHER (5 DAR5 OR SMALLER) 1 I/1• •SLABS AND WALLS (INTERIOR FACE) 314' 447. D8R5 SHALT- DE SUPPORTED ON CHOIRS OR DODIE DRICKS. B. ANCHOR BOLTS TO CONFORM TO A501 A301. 14. NON -SHRINK GROUT SHALL DE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL 55 MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MMiFACTURER 5 R)DL154ED RECOMMENDATIONS. GLUT STRENGTH SHALL BE AT LEAST 50UAL TO 714E MATERIAL CN WHICH IT 15 PLACED (3000 PSI MINIM1 A R EVIEWED pLINANCE CODE C APPROVED JUL 1 0 2001 CP Q Tukwila B LD NG DIVISION STRUCTURAL STEEL NOTES: l SHOP DRAWINGS FOR 5112UCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. 2. STRUCTURAL STEEL DESIGN, FADRIC4TION, PANTING AND ERECTION (INCLUDING FIELD WELDING, 14404 STRENGTH FIELD 501.155 ExP4N51ON DOLTS. AND TIRE4DED EXPANSION ANCNOR9) &NALL BE 545ED ON 114E A191.. 'SPECIFICATION FOR 745 DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR DUILDINGS• LATEST EDITION. SUPERVISION SHALL DE IN ACCORDANCE WITH 6144PTER 11 OF THE IBC 7003 57 4 QUALIFIED TESTING AGENCY DESIGNATED 57 THE CONSULTANT. THE CONSULTANT SHALL DE ()514451-ED 10144 A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. 3. STRUCTURAL STEEL 54441.1. CONFORM TO 7445 FOLLOWING F TYPE CP MEMBER A B. C. D. E. F. PLATES, 5444PES, ANGLE5, AND RODS SPECIAL 5444PE5 AND PLATES PIPE COLUMNS STRUCTURAL 1U5ING ANCHOR BOLTS CONNECTION COLTS 4. ALL MATERI41. TO DE 1401 DIPPED GALVANIZED AFTER FABRICATION PER 403/40311-00. 5. ALL WELDING SHALL BE IN CONFORMANCE WAT44 4.195. AND 4W5 STANDARDS ANC SHALL DE PERFORMED BY WAB.O. CERTIFIED WELDERS U5NG 510 XX ELECTRODES. ONLY P54 WELDS (A5 DEFINED BY 4W5) SHALL BE USED. WELDING OF GRADE 60 REINFORCING BARS (IF 55QUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING CF GRADE 40 R BARS (IF 5CUIFZ_0) SHALL BE PERFORMED USING 510 XX ELECTRODES. WELDING WITHIN 4. OF COLD BENDS N RERFORCNG STEEL 15 NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. 45141 A36, Fy 36 K91 A5TM A512. F4 50 K51 45741 453, 1 35 3(51 45141 4500, 59 46 K51 ASTM 4301 4511 A325 TLU6T -OFF -TYPE 6. COLD - FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON THE PLA145. PROVIDE 111N51U1 SECTION PROPERTIES INDICATED. ALL COLD - FORTED STEEL FRAMING SHALL CONFORM TO T145 4199. '5PECFI0411ON FOR TFE DESIGN CF COLD - FORMED STEEL STRUCTURAL MEMBERS.• 1. BOLTED CONNECTIONS SHALL USE BE4RRG TYPE 45141 A325 BOLTS (3/4' DI4) AND SHALL HAVE A 115M.11 OF TWO BOLTS UNLESS NOTED OTHERN55 ALL ASSEMBLY ARE TO DE TIGHTENED 54 ACCORDANCE WITH '5PECFICATION FOR 515 4/URAL JONT5 U5NG A5141 A325 OR 4490'. ,3444E 30, 7004. FOR BEARING -TYPE CONAECTION5, AS A MNII-ILM THE BOLTS SHALL DE TIGHTENED TO A 'SNUG 74014T' CONDITION AS DEFINED N tHE ABOVE REFERENCED CODE 8. NON - STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8' DIA. 45141 4301 BOLTS UNLESS NOTED 014455255. S ALL ILELDS TO BE V4• FILLET UNLESS NOTED OTHERWISE 10. TOUCH U° ALL FIELD DRILLING AND 1151.0 G WITH 2 COATS OF GALVACON (ZNC 51614 PANT) OR APPROVED EOU4L SPECIAL INSPECTIONS: SPECIAL NSPECTI04S N ACCORDANCE WITH SECTION 44104 CF 1145 IOC 7003, 501L5.GEOTEC4NICAL. ❑ SHORING INSTALLATION AND MONITORING ❑ OBSERVE AND MONITOR EXCAVATION ❑ VERIFY SOIL DEARING P5F SEARING ❑ 511DS1RFACE DRAINAGE PLACE- 4n. ❑ VERIFY FILL MATERIAL AND COMPACTION ❑ VERIFY CONDITIONS AS ANTICIPATED ❑ PILE PLACEMENT (AUGER CAST/DRIVEN PILE) ❑ OTHER REINFORCED CONCRETE. ❑ REINFORCING STEEL AND CONCRETE PLACEMENT ❑ PRESTRESSED/PRECAST CONCRETE FABRICATION AND ERECTION ❑ 341C4PLANT AN'PECTION ❑ SHOTCRETE ❑ GROUTING ❑ OTHER STRUCTURAL STEEL ❑ FABRICATION AND SHOP WIELDS ❑ ERECTION AND FIELD WELDS AND BOLTING ❑ OTHER STRUCTURAL 41.431IN M: ❑ FABRICATION AND SHOP WELDS ❑ ERECTION. FIELD WELDS AND BOLTING ❑ OTHER 51510/URAL 44450NAR7, ❑ cONTINUOUS ❑ PERIODIC 0 OTHER ANCHORING TO CONCRETE: ❑ BOLTS INSTALLED IN CONCRETE ❑ POST- INSTALLATION ADHESIVE ANCHORS ❑ POST•NSTALLATION MECHANICAL ANCHORS t 1"! 37904 IEX»v,ES 11 /0614 JUN 27 2101 we 01 REA'LCOM K E /� NGINEERING 701 - 11688 - 66114 AVE SURREY, BC V35 1X1 CANADA TEL. (604)514 -6432 FAX, (604) 514 -6431 TOLL FREE. 1 -811- 345 -4045 EMAIL, n4ll•trkenscon WEB weG.trkengcvn PROJECT Na 0630 - 020 I DR•YN er. I 0E0CED DT. FM. 0.40 FILL: 0630.020• SUBMITTALS 0 • JUI »411 AA Il /01 RED 1101 JAI 33/01 65?00 L RCV10I0N5 MEWED FOR SP./CONEY. GENeRAL REVISKN5 155100 FOR REVIEW THE INFORMATION CONTAINED N 74415 SET CF 000.45 NT5 15 PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER 114AN THAT WHICH RELATES TO THE CLIENT NAMED 15 STRICTLY PRO4151TED. •JE 5541. RECEIVED JUN 2 8 2007 PERMIT CENTER, 617E 5EA BRISCO WOO ORILLIA RD 5 TUKWILA, WA 51EET TITLE SPECIFICATIONS 514557 NUMBER A -1 i �4 Il ft7 2 • ./ • . 1: • • ASPHALT ROAD / I • • . • • • • • • \ •\ - • • TELEPHONE POLE • • • \ . • • • • • • • • • • • • • \ • \ • • • • • • • - 1 \ •\ • • • • • • • • \ -\ • • - "tea • a • • .1 •.•1• ••• It. 4 • • • • \• \• • • liBAtJDONNED . . - 5•,, \ . . . • • / • • • • • . �. . \•\ • . I I. • • • . • • EXISTING GRASS. _/ • • \ •-•-4 + • • \v • I • 1• . • . • . • . • � • . AREA • .. ± . ` • : ♦ . . \. \b� I / . . . . • REFER TO'A -3 FOR •COMP01111? LAYOUT • \ 1 . . • • . • • • . \ \ • • • • • • • • \ \ a� • • • • • \ \ a �a . • EXI$TN3 DIRT \\ \\ ° ' mo o , ACCE85 ROAD EXISTING POWER POLE a— a— EXISTING CHANLINK FENCE 10 '. 0 " EASEMENT APPROXIMATE SCALE LOCATIONS EXISTING TRANSFER STATION TOLL •BOOTN • EXISTING • POWER POLE FOUND 4 "x4• RIGHT --\ OF WAY MONUMENT // CD SITE PLAN 0 10 20 50 T 7 \ • .I • / • I• /• • / I GUY POLE CONNECTING TO EXISTING POWER POLE TO THE WEST T 352304.5018 TAX 52304 -9018 AX LOT NO. EXISTING TREE LINE / / / 10' -0 / / EASEMENT / / / / / / I -N - 7 / J 1 -, / I I / 4- I--' J- I TJ� / / / / / / / / / / / 0 0 In 2 51 w EXISTING 2 BUILDING TAX LOT NO. 352304 -9031 FOUND 4 "x4" RIGHT OF WAY MONUMENT 1 1 / 1 I 1 i I / I 34 3 TRUE NORTH ARROIU 5110LLN ON THIS DRAWING 19 APPROXIMATE ONLY AND MUST BE VERIFIED EY CONTRACTOR i i I I I 1 / I ,5 81'56'02" E 1 1 9600' i TAX LOT NO. TAX LOT NO. 352304 -9031 l/ ,//;2 1/ //Y /i // �i ' /�- / i S* s -e. IJ -/ 1/ �'T _ _ � x}1.51'00" g 123831' I 1•,.._. TAX LOT NO. 352304 -9015 352304-9016 • FOUND MONUMENT AT INTERSECTION OF 5 188T1-1 5T AND THE / OFF /ON RAMPS OF 1-5/ FOUND MONUMENT AT THE SOUTHWEST SECTION CORNER OF SEC. 35, TWP. 23 N, RING. 4 E. WM. NOTES: 2 BOUNDARY PLAN 0 50 160 240 L SITE PLAN INFORMATION WAS OBTAINED FROM AN EXISTING DRAWING PROVIDED BY OTHERS AND FIELD MEASUREMENTS TAKEN BY TRIG ENGINEERING LTD. ON OCTOBER 26. 2006. 71415 DRAWN' DOES NOT REPRESENT A SURVEY. ALL DIMENSIONS TO PROPERTY LIES ARE APPROXIMATE ONLY. LEGAL DESCRIPTION: BEGINNING AT THE WEST V4 CORNER OF 5ECTICN 35, TOINSHIP 23 NORTH, RANGE 4 EAST, W2t• THENCE SOUTH 51'56' EAST 960 FEET; THENCE SOUTH 337459• WE57 12151 FEET; THENCE SOUTH 35'42'02 EAST 114463 FEET; THENCE SOUTH 4 WEST 490 FEET; THENCE NORTH 51'51' WEST 123531 FEET; THENCE NORTH 5'44'13• EAST 151511 FEET 70 BEGINNING; EXCEPT ROADS; EXCEPT STATE HIGHWAY SITUATE N THE COUNTY CF KING. STATE CF W4WINGTON PER TITLE R NO. N3II915 ISSUED BY FIDELITY NATIONAL TITLE COMPANY OF WASHINGTON 2 X \9 I 1 73\ � TAX LOT NO. 1\ 352304 -9051 1 \ TAX LOT NO. 352304 -9065 // /4 // ' 1/ // // // /1 ,/ 1/ 11 TAX LOT NO. 352304 -031 TAX LOT NO. 352304 -9045 TAX LOT NO. 352304 -9034 I _ TAX LOT NO. JUN 2 7 2007 ExP:RE.S 11/06/07 veA7 v,ireIess REA'LCOM 1 11.. ENGINEERING •201 - n605 . 66714 AVE SURREY, BC V39 1X4 CANADA TEL. (604) 514 -6432 FAX, (604) 514 -6431 TOLL FREE, I -511. 345 -4045 EMAIL, nen•vken9 U.EB, .. utt* 15 4.l 'PROJECT NJO, 0630 -020 'DRAM DT, GN I QEOCED DT, FM. I CAO PILE, a)0-0)042 SUBMITTALS • J UN 2S/01 An 0/01 RD 5101 JAN 23101 GENERAL I2v1610b IDE ED FOR SP.CONST. GENERAL REVDIW6 IDDED PORI WHEW 74E INFORMATION CONTAINED IN THI5 SET CF D0CIMETIT5 15 PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER 734431 THAT W4104 RELATES TO 714E CLIENT NAMED 15 STRICTLY PROHIBITED. 422 35AL RECEIVED JUN Z 8 2007 PERMIT CENTER ERE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SWEET TITLE SITE PLAN 611EET NUMBER A -2 TRUE NORTH ARROW N-OUN CN THIS DRAWING IS APPROXIMATE ONLY AND MUST DE VERIFIED BY CONTRACTOR EXISTING CHAINLINK FENCE CAL PRIVACY SLATS EXISTING VERIZON WIRELESS EQUIPMENT CABINET, TYPO EXISTING ELECTRICAL CABINET EXISTING VERIZON WIRELESS ELECTRICAL NI-FRAME EXISTING VERIZON WIRELESS SERVICE METER EXISTING TELCO PEDESTAL EXISTING VOICESTREAM WAVEGUIDE BRIDGE EXISTNG WOOD UTILITY POLE EXISTING EQUIPMENT PAD CAD EQUIPMENT • • 14' -II' (EXISTING GRASS AREA ...fail 1 IU I d • • C EXISTING GRASS AREA I EXISTING VERIZON WIRELESS RAISED • PLATFORM CM EQUIPMENT CABINETS • UTILIZE EXISTING VERIZON WIRELESS WAVEGUIDE BRIDGE TO ROUTE ANTENNA CABLE TO MONOPOLE EXISTING RIDGE OF BANK EXISTING MONOPOLE ANTENNAS NOT 5FI01151 FOR CLARITY. REFER TO A -4 FOR VERIZON WIRELESS ANTENNA LAYOUT EXISTING MONOPOLE FOUNDATION I. EXISTING ELECTRICAL W -FRAME CM ICE BRIDGE EXISTING GUY TIRE * EXISTING VOICESTREAM EQUIPMENT PAD CALI EQUIPMENT 0 COMPOUND LAYOUT 0 I 2 5 NOTES: t CONTRACTOR TO PROVIDE ALL REQUIRED HARDWARE NECESSARY TO FACILITATE ANTENNA CABLE ROUTING FROM EQUIPMENT TO ANTENNA$. 2. CONTRACTORS WOW SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE. AND LOCAL CODES AS ADOPTED Sr THE LOCAL AUTHORITY WAVING JURISDICTION (AHD FOR THE LOCATION. THE EDITION CF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE CF CONTRACT AWARD SHALL GOVERN TI-E DESIGN. 3. PANT ANTETNA, ANTETNA PIPE MOUNT, ANTEN.IA CABLES AND HARDWARE TO MATCH EXISTING. 0 CODE COMPLIANCE FOR M,(�gN z APPROVED JUL I 0 zoar N re B City DFTukwila . IN / • i ' d STn x ExlIRES 11/06/07 JUN 2 7 2LO7 VerIZ v ireless RERLCOM EN GINEERING n01 - n68S - 66T1.1 AVE SURREY, BC V35 TXt CANADA TEL, (604) 514 -6432 FAX, (604) 514 -6431 TOLL FREE, I -511 -945 -4045 EMAIL, via 11atrl,e g.... WED, WWW.trkangcan I FT5NECT NOS 0630 - 020 I PRNN 5Y. GK I OEGKED Er. EM. I CAO FWE. 0630 -d)OU SUBMITTALS 0 S AN l3/al APR 1Lal FEE IYOI JAN 23/O1 CIErER•L REVISIONS MINED FOR SU'.CO,ST. GENERAL REVISIONS 151450 F REVIEW THE RFOR TATICN CONTAINED N THIS SET OF DCO.IIENTS IS PROPRIETARY DT NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT Wk1IC1.1 RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. As! SEAL RECEIVED JUN 2-8 2007 PERMIT CENTE SITE SEA BRISCO 15100 ORILLIA RD S TUKWILA, WA R SWEET TITLE COMPOUND LAYOUT SWEET NUMBER A-3 WOOD UTILITY POLE OVERHEAD UTILITY LINE GUY WIRE T- MOBILE WAVEGUIDE BRIDGE TELCO PEDESTAL CHAIN/LINK FENCE CIW PRIVACY SLATS T- MOBILE EQUIPMENT PAD CAU EQUIPMENT ELECTRICAL 14-FRAME CN1 ICE BRIDGE r_r r pr p n� �� IJ NiNlu °EXISTING EAST ELEVATION I 4 9 LIGHTNING ROD TA. MONOPOLE 60' -0 "3 AGL. 5T -6"t AGL. EMPTY TOP ANTENNA PLATFORM VERIZON WIRELESS RAD CENTER 41' -6 "t AGL. REFER TO DETAIL 2 FOR EXISTING ANTENNA LAYOUT AT 4T -0" AGL T- MOBILE RAD CENTER 38' -0 "3 AGL. VOICESTREAM ANTENNA PLATFORM 01W (4) ANTENNAS 60' -0" MONOPOLE VERIZON WIRELESS ANTENNA WAVEGUIDE BRIDGE VERIZON WIRELESS SERVICE METER VERIZON WIRELESS ELECTRICAL 14-FRAME VERIZON WINLESS EQUIPMENT CABINET VERIZON WINLESS PLATFORM CM EQUIPMENT CABINETS VERIZON EQUIPMENT PAD MONOPOLE FOUNDATION TRUE NORTH ARROW 91-10UN ON 11415 DRAWING IS APPROXIMATE ONLY AND MUST BE VERIFIED BY CONTRACTOR GAMMA SECTOR AZIMUTH • 255' NOTE: ALL EXISTING VERIZON WIRELESS ANTENNA CABLES TO BE REMOVED EXISTING ANTENNA CABLES TOTAL CF (8) ANTENNA CABLES REVIEWED L A COD FOR E APPROVED JUL 1 0 2007 City Of Tukwila B ILDING DNISI N NOTES: L ELEVATION 15 DIAGRAMMATIC OILY. VERIZON WIRELESS PANEL ANTENNA n OF B MONOPOLE ALPHA SECTOR AZIMUTH TBD. VERIZON WIRELESS ANTENNA PLATFORM ° EXISTING ANTENNA LAYOUT AT 41 -6 A.G.L. N.T,S. I EXPiPES 11/06/07 JUN 27N110O Wei ilz2mwireless RE*'LCOM K / ENGINEERING .201 - 11688 - 66T14 AYE SURREY. BC V35 1XI, CANADA TEL: (604)514-6A32 FAX, (604) 514-6431 TOLL FREE: I -811- 345 -4045 EMAIL: na llallka.s••• WED+ satctrk ine.con I PROJECT Na 0630 I DRAW DT. ax IO€ 'ED eT. Flt I CAO FILE. 0530 -07044 SUBMITTALS • B • AN »101 AP! I1rO1 FED RJOI JAN 73ro1 6EI0RAL REV SOTS MELEE, FOR 8P.CON6T. DE REVENENE 1661!0 FOR REVIEW THE RFORIATICN CONTARED N THIS SET CF DOOJ'IENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT UIICH RELATES TO THE CLIENT NAMED 8 STRICTLY PROHIBITED. AI! 6041.prr RE6E V EL JUN 2 2007 PERMIT CENTEF SITE SEA BRISCO 15100 ORILLIA RD S TUKWILA, WA SHEET TITLE EXISTING EAST ELEVATION SHEET NEIBER A -4 T- MOBILE 5ECTOR ADD CN) 2 PANEL ANTENNAS AND MOUNTING HARDWARE. R_R1OVE ALL EXISTING T- MOBILE ANTENNA CABLES AND REPLACE WITH A TOTAL OF (12) 1/5" ANTENNA CABLES. T1415 WO ( TO BE DONE UNDER SEPERATE CONTRACT EXISTING WOOD UTILITY POLE EXISTING OVERHEAD UTILITY LINE EXISTING GUY WIRE EXISTING T- MOBILE WAVEGUIDE BRIDGE EXISTING TELCO PEDESTAL EXISTING CHANLINK FENCE CAU PRIVACY SLATS EXISTING T- MOBILE EQUIPMENT PAD CAU EQUIPMENT EXISTING ELECTRICAL 14-FRAME CN) ICE BRIDGE LIGHTNING ROD REFER TO DETAIL 3 FOR VERIZON WIRELESS ANTENNA LAYOUT T.O. EXISTING MONOPOLE / ANTENNA TIP HEIGHT 60' -0 11 t AGL. RELOCATE EXISTING VERIZON U RELE55 ANTENNAS TO TOP PLATFORM AS 51409.N EXISTING RAD CENTER 41' -6 "t AGL. RELOCATE EXISTING T- MOBILE ANTENNAS TO EXISTING PLATFORM AT 41' -6" AS SHOWN. THIS WORK TO BE DONE UNDER SEPERATE CONTRACT EXISTING RAD CENTER 38' -0 "9 AGL EXISTING 60' -0" MONOPOLE UTILIZE EXISTING VERIZON WIRELESS ANTENNA WAVEGUIDE BRIDGE TO ROUTE ANTENNA CABLE TO MONOPOLE. PROVIDE ANY ADDITIONAL HARDWARE TO FACILITATE INSTALLATION VERIZON WIRELESS SERVICE METER EXISTING VERIZCN WIRELESS ELECTRICAL I4-FRAME EXISTING VERIZON WIRELESS EQUIPMENT CABINET EXISTING VERIZON WINLESS PLATFORM CIW EQUIPMENT CARNETS EXISTING VER ZON WIRELESS EQUIPMENT PAD EXISTING MONOPOLE FOUNDATION TR1.E NORTH ARROW SHOWN a4 THIS DRAWING 19 APPROXIMATE ONLY AND MUST BE VERIFIED BY CONTRACTOR RELOCATE EXISTING VERIZCN WINLESS 950M1Nz PANEL ANTENNA A5 SHOLLN, TYP. OF 2. REFER TO DESIGN BOOK FOR ANTENNA DETAILS RELOCATE EXISTING YERIZON WIRELESS 1500MHz PANEL ANTENNA AS SHOLLN, TYP. OF 2. REFER TO DESIGN BOOK FOR ANTENNA DETAILS NOTE. ROTATE TOP PLATFORM TO FACILITATE NEW ANTENNA AZIMUTH EXISTING / PROPOSED ANTENNA CABLES TOTAL OF (9) ANTENNA CABLES NOTES: L ELEVATION 19 DIAGRAMMATIC CN.Y. 4. PANT ANTENNA, ANTENNA PIPE M0NT. ANTENNA CABLES AND HARDWARE TO MATCH EXISTING. RELOCATE EXISTING VERIZON WIRELESS ANTENNA AS SHOWN, TYP. OF 4. REFER TO DESIGN BOOK FOR ANTENNA DETAILS 2. CONTRACTOR 10 PROVIDE ALL REQUIF HARDWA/ NECESSARY TO FACILITATE ANTENNA CABLE ROUTING FROM ECUIPMENT TO ANTENNAS. 3. CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL. STATE. AND LOCAL. CODES AS ADOPTED EY THE LOCAL AUTNORITY RAVING JURISDICTION (AND FOR THE LOCATION. THE EDITION OF 114E AA) ADOPTED CODES AND STANDARDS N EFFECT ON T14E DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. EXISTING MONOPOLE PROPOSED VERIZON WIRELESS 10 ANTENNA LAYOUT AT S7' -6" A.G.L. NT.5. ROTATE EXISTING TOP ANTENNA PLATFORM TO ACHIEVE VERIZON WIRELESS ANTENNA AZIMUTHS I ExNPES 111061 °7 JUN 2 7 2007 RE�►'LCOM 4 201 - 41688 - 66T14 AVE SURREY. BC V39 1X1, CANADA TEL. (604) 914 -6432 FAX, (604) 514 -9431 TOLL FREE. 1- 811 - 345 -4049 EMAIL. nalNtrkangtpn WEB, aRw.vkangton 0630 -020 0630 -020AI SUBMITTALS bENERAL REVISION6 ISSUED FOR RENEW THE RFOR1ATIGN CONTAINED N 1413 SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN 114A2 911104 RELATES TO THE CLIENT NAMED 13 STRICTLY PROHIBITED. A2 3E4 L RECEIVED JUN 2=8 2007 PERMIT GENTEF SEA BRISCO 15100 ORILLIA RD S TUKUJILA, WA SHEET TITLE PROPOSED EAST ELEVATION SHEET 5111885 TO. EXISTING MONOPOLE / ANTENNA TIP HEIGHT 60' - 0 ": "t A.GL. RELOCATE EXISTING VERIZON WIRELESS ANTENNAS TO TOP PLATFORM AS SHOUN EXISTING RAD CENTER 41' -6 "t AGL RELOCATE EXISTING T- MOBILE ANTENNAS TO EXISTING PLATFORM AT 41' -6" AS 5HOU.N. THIS WORK TO BE DONE UNDER SEPERATE CONTRACT EXISTING RAD CENTER 35' -0 "t AGL EXISTING VERIZON WIRELESS EQUIPMENT CABINET °PROPOSED WEST ELEVATION m 2 4 LIGHTNING ROD REFER TO DETAIL 3 FOR VERIZON WIRELESS ANTENNA LAYOUT T- MOBILE SECTOR ADD C/W 2 PANEL ANTENNAS AND MOINTING HARDWARE. REMOVE ALL EXISTING T- MOBILE ANTENNA CABLES AND REPLACE WITH A TOTAL OF 02)1/5" ANTENNA CABLES. THIS UIORK TO BE DONE UNDER SEPERATE CONTRACT EXISTING WOOD UTILITY POLE EXISTING OVERHEAD UTILITY LINE EXISTING 60 - 0' MONOPOLE EXISTING GUY WIRE EXISTING T- MOBILE WAVEGUIDE BRIDGE EXISTING CHAINLINK FENCE C/W PRIVACY SLATS NOTES: L ELEVATION IS DIAGRAMMATIC ONLY. 2. CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL. STATE. AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AFL') FOR THE LOCATION. THE EDITION OF THE AHl ADOPTED CODES AND STANDARDS M EFFECT CFI THE DATE OF CONTRACT ALARD SHALL GOVERN THE DESIGN. OOp FOR C OMPLIANCE A PPROVED JUL 10 1007 City B Of Tukwila IN DIVIs Q I EXPI P ES 1 JUN 2 7 2007 veWR@IeSS REA'LCOM 1 E NGINEERING '201 - Hass - 66TH AVE SURREY, BC V35 IXL CANADA TEL. (604) 514 -6432 FAX. (604)514 -6431 TOLL FREE. I -D11. 345 -4045 EMAIL. naU•t,keng<on U.EB. ww.t* P5Aon PROJECT NP 0630-020 0R.A. BT. GIL I GEOCED 6T. PM CAD FILE. 0630 -020A6 SUBMITTALS • B All 23.1 APR 11,01 FED 14/01 JAN 24/01 GENERAL RE VISORS 1661CD POR PPJCWST. GENERAL REVU,OS 16611E0 POR REVIEW TIE ',FORMATION CONTAINED N THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT UNION RELATES TO 11.• CLIENT NAMED IS STRICTLY PROHIBITED. AR SEAL RECEIVED JUN 218 Z007 PERMIT CENTE SITE 5EA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SLEET TITLE PROPOSED WEST ELEVATION SWEET NUMBER A -6 EXISTING T- MOBILE EQUIPMENT CABINET EXISTING ELECTRICAL 14-FRAME CM ICE BRIDGE C .I 1tuvu 11111111111111IIIIIII IIIIIII CD 11•11.11 11 I PROPOSED NORTI -I ELEVATION 0 2 4 8 LIGHTNING ROD REFER TO DETAIL 3 FOR VERIZON WIRELESS ANTENNA LAYOUT TA. EXISTING MONOPOLE / ANTENNA TIP HEIGHT 6O' - 0 "t A. RELOCATE EXISTING VERIZON WIRELESS ANTENNAS TO TOP PLATFORM AS SHOWN EXISTING RAD CENTER 41' -6 "t AGL RELOCATE EXISTING T- MOBILE ANTENNAS TO EXISTING PLATFORM AT 4T -6" AS S4-1OW4. THIS WORK TO BE DONE UNDER SEPERATE CONTRACT EXISTING RAD CENTER 3B' -0 "t AGL EXISTING 60' -0" MONOPOLE EXISTING WOOD UTILITY POLE EXISTING VERIZON WIRELESS EQUIPMENT CABINET REVIEWED FOR CODE COMPLIANCE APPROVED JUL 10 2007 City Of Tukwila B I MOMS. EXISTING VERIZON WIRELESS ELECTRICAL H -FRAME N O PROPOSED SOUTH ELEVATION 0 J 4 8 NOTES: L ELEVATION IS DIAGRAMMATIC ONLY. 2. CONTRACTOR'S WORK SHALL CC IDLY WITH ALL APPLICABLE NATIONAL, STATE, ANA LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY I4AVNG JURISDICTION (A U) FOR TIE LOCATION. THE EDITION CF THE AHJ ADOPTED CODES AND STANDARDS N EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. LIGHTNING ROD REFER TO DETAIL 3 FOR VERIZON WIRELESS ANTENNA LAYOUT T.O. EXISTNC MONOPOLE / ANTENNA TIP HEIGHT 60' -0 "t AGL. RELOCATE EXISTING VERIZON WIRELESS ANTENNAS TO TOP PLATFORM AS SHOWN EXISTING RAD CENTER 41' -6 "t A.G.L. RELOCATE EXISTING T- MOBILE ANTENNAS TO EXISTING PLATFORM AT 41' -6" AS 54-101.114. THIS WORK TO BE DONE UNDER SEPERATE CONTRACT EXISTING RAD CENTER 38' -0 "t AGL EXISTING 60' -0" MONOPOLE EXISTING VERIZON WIRELESS EQUIPMENT CABINET EXISTING ELECTRICAL I4-FRAME CM ICE BRIDGE EXISTING T- MOBILE EQUIPMENT PAD C/IU EQUIPMENT EXPIRES 11/06/07 JUN 2 72007 Verrwireless RERLCOM i f z I' ERING 4 101 - n638 - 66T14 AVE SUR2mY, BC V35 TXL CANADA TEL. (604) 514.6432 FAX (604) 514.6431 TOLL FREE. I -811- 345 -4045 EMAIL. naIl.trks'.9con SEE. uuw.trkenacon PROJECT Na 0630 - 030 IDRAIN BY, GA. I O•EOCED OT. Fri CAD FILE, 0630 -01041 SUBMITTALS • e A .Da 36,01 APR NO1 FED ISM. JAN 33,01 GENERAL REVI610N6 M61ED FOR Bl/CONST. GENERA- REVISIONS 116 20 FOR REv1EW THE INFORMATION CONTAINED N THIS SET OF DO0MENTS 15 PROPRIETARY er NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMED IA STRICTLY PROHIBITED. 4JE 6044. RECEWED JUN 28 2007 PERMIT CENTE SITE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SHEET TITLE PROPOSED NORTH AND SOUTH ELEVATIONS SHEET NUMBER WEATHERPROOFING KIT (REFER NOTE 3) NOEL 2. 3. C ANTENNA CABLE CONNECTOR 120• MAX. TO 24•, TYP. ANTENNA CABLE 1 IIIIIIPppI' �mi1 =J1=== . DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. GRCUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER WEATHER PROOFING SHALL BE TWO -PART TAPE KIT, COLD SHRINK SHALL NOT BE USED 19 ALLG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (REFER NOTES I AND 2) CABLE GROUND KR CD ANTENNA CABLE GROUND KIT DETAIL N.T.S. '2/0 TW GREEN TO EXISTING GROUND RING TINNED COPPER I-IARGER GROUNDING BAR 'GBII44ISG OR APPROVED EQUAL '2/0 TB GREEN TO GROUND BAR MOUNTED TO TOILER NEAR ANTENNAS '2/0 TW GREEN TO EXISTING GROUND RING GROUND TAILS, TYP. O GROUND BAR DETAIL NTA. GROUNDING SPECIFICATION L GROJ1DNG SHALL COMPLY WITH LATEST EDITION CF THE NATIONAL ELECTRICAL CODE AND VERIZCN WIRELESS STANDARDS. 2. MINMU•I BENDING RADIUS FOR GRO ID CONDUCTOR IS S•. 3. NO SPLICES PERMITTED M GROUND CONDUCTORS. 4. INTERCONNECT ANTENNA GROUND LUG TO S SOLID BARE TINNED COPPER (IF APPLICABLE) 5. ALL GROUNDING CONNECTORS TO BE CLEAN AID FREE OF PANT AT THEIR MATING SURFACES AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. USE PENETROX OR EQUIVALENT ANTIOXIDANT GR 6. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG 5/S• BOLT CONNECTOR COMPRESSION TYPE. STACKED CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND EAR WILL BE PERMITTED. 1. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED VALUES. S. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BY AT LEAST 6•. S. TIAXMU I RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED A RESISTANCE OF 5 OHMS TO EARTH. 10. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES N ANT METAL OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISHNG A •CHOKE• POINT. IL FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUND WIRE SHALL NOT BE USED. METAL CLIPS TWAT DO NOT COMPLETELY SURROUND THE GROUND WIRE OR PLASTIC CLIPS 4� ACCEPTABLE. 12. GROUND BARS SHALL NOT BE FIELD MODIFIED. 13. VERIFY ALL GROUND CONNECTIONS WTH SHELTER ON SITE. 14. ALL EXTERIOR GROUND BARS TO DE TINNED COPPER PROVIDE GROUND KITS FOR ANTENNA CABLES AT GROUND BAR LOCATIONS AS REQUIRED CODE' DEL .._ �OMP NCE APP ROVED JUL I 1 Gty Of Tukwil a ILpIAf p EXPIRES 6911 1/ ,, co JUN 272007 VeL.L.mwireless RE*'LCOM i T z I GINEERING *201- I165B - 66114 AVE SURREY, DC V35 TXL CANADA TEL, (604) 514.6432 FAX, (604) 514.6431 TOLL FREE, 1- 611.345 -4045 EMAIL, nelletrkenEna, "E6, uR.o.vks gcan PROJECT PO 0630 - m, I DRAM OT, GH I CWEUCED OT, 61W CAD P U, 0630 -0)0EI SUBMITTALS e Jul 26/el APR N01 PEE I3/01 JAN ]3roT GENERAL RECISION! MERE PDR EPJCONST. GENERAL REWNON6 1650D FOR RENEW THE RFOR'1ATION CONTAINED N THIS SET OF DO0l1ENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT ERICH RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. A2 0E41. RECEIVED JUN 2'8 2007 3 ERMIT CENTER SITE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SI-SET TITLE GROUNDING DETAILS SHEET NUMBER E -1