Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D07-243 - LINCOLN CENTER HOLDINGS - RAMP AND STAIRS
LINCOLN CENTER HOLDINGS 1104 ANDOVER PK W D07 -243 Parcel No.: 3523049053 Address: 1104 ANDOVER PK W TUKW Suite No: Citysf Tukwila Tenant: Name: LINCOLN CENTER HOLDINGS Address: 1104 ANDOVER PK W , TUKWILA WA doc: IBC-10 /06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: GREGG PERCICH Address: 603 STEWART ST, #707 , SEATTLE WA 98101 Phone: 206 - 624 -3210 Contractor: Name: JOHNSON TENANT IMPROVEMENT INC Address: P.O. BOX 1149 , BOTHELL, WA 98041 -1149 Phone: 206 660 -5286 Contractor License No: JOHNSTI092PA DESCRIPTION OF WORK: INSTALL NEW ACCESS RAMP AND STAIRS. DEVELOPMENT PERMIT Owner: Name: LINCOLN CENTER HOLDINGS Address: C/O R J HALLISSEY CO INC , 12835 BEL -RED RD #140 98005 Phone: Value of Construction: $25,000.00 Fees Collected: $804.72 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: III -B Occupancy per IBC: 0008 * *continued on next page ** Permit Number: D07 -243 Issue Date: 09/12/2007 Permit Expires On: 03/10/2008 Expiration Date: 10/07/2007 D07 -243 Printed: 09 -12 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Meter: governing this work will be compile doc: IBC-10/06 City GsriTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D07 -243 Issue Date: 09/12/2007 Permit Expires On: 03/10/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: N Permit Center Authorized Signature: Date: I 4 12'f' `,1 I hereby certify that I have read an ex- ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o performance of work. I am authorized to sign and obtain this development permit. Signature: Date: 94, 4 7 Print Name: 1 > o (- / VIR This permit shall become mill and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -243 Printed: 09-12 -2007 Parcel No.: 3523049053 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1104 ANDOVER PK W TUKW LINCOLN CENTER HOLDINGS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of 'Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: D07 -243 ISSUED 06/29/2007 09/12/2007 D07 -243 Printed: 09 -12 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: A-2-A, 007 -243 Printed: 09 -12 -2007 CITY OF TUKWILC Community Developmarbepartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tuk Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 104. C Vt — i ? v,/e53 Property Owners Name: L hhtCot-44 CEA/MX- Ibt,.13 Mailing Address: IZ 1 ptab Name: j ` CAC.t-4 Mailing Address: ( ( 9AIX' lam^- 14 101 E -Mail Address: ei�A',rGte,�,�. e.. � i� . ct GENERAL CNST I RACTOR "INFORMATION - (Contractor Information for Mechanical (pg 4) for P lumbing and Gas Piping (pg 5)) Contact Person: E -Mail Address: Contractor Registration Number: Company Name: AE. Ala-CA-1 Mailing Address: (Q03 City Contact Person Contact Person: E -Mail Address: Q:Wppliations\Fonns- Applications On Line U-2006 - Permit Application.doc Revised: 9-2006 bh King Co Assessor's Tax No.: %S2.3()1 - Gj D S 3 -(i_S' Suite Number: — Tenant Name: — New Tenant: ❑ .... Yes f..No 6/0 4 • (31 tle.:ee. _ j oHL. ■.v.q 'VMS City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: b G (ol`f Z,zi (7 T1z r ■VA tot State City . Floor: Fax Number: Z. (p (oZ`-( 32 Zip Company Name: . Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record E -Mail Address: e' e ENGINEER RECORD - All plans must be wet stamped by Engineer, of Recoc C t , (O1 State Zip Day Telephone: Zp (p 672 )1 3 210 Fax Number: '!i) Co (o7.9 ' 2k Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Page 1 of 6 131141LLINl YEK MI 111 F U A11ON — 2 Ub 431 367 Valuation of Project (contractor's bid price $ I SO CO Existing Building Valuation: $ Scope of Work (please provide detailed information): �(�� , � 5 'Z641) G.. j �Z6 Will there be new rack storage? ❑.... Yes )) No If yes, a separate permit and plan submittal will be required. Q PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 6165 Floor area of principal dwelling: — Floor area of accessory dwelling: r *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: CISG Compact: 'fix I �j Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty, Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas 1LUMBING AND GAS PIPINCERMIT INFORMATION 206-43 PLUMBING AND GAS CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\ApplicationsWonns- Applications On LineN3 -2006 - Permit Application.doc Revised: 9-2006 bh Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: Mailing Address: (00 S i t i,A �j' 0 10i Date Application Expires: Ii-1A 0 Date Application Accepted U — Z 6 1 - 01 HORIZED AGENT: Q:\Applications\Forms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: City Date: (0 -2 Olt Ib [ O I State Ztp Staff Initial Page 6 of 6 Parcel No.: 3523049053 Permit Number: D07 -243 Address: 1104 ANDOVER PK W TUICW Status: PENDING Suite No: Applied Date: 06/29/2007 Applicant: LINCOLN CENTER HOLDINGS Issue Date: Receipt No.: R07 -01267 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Initials: BLH Payment Date: 06/29/2007 03:51 PM User ID: ADMIN Balance: $0.00 Payee: SHEPHARD COMM REAL ESTATE LLC TRANSACTION LIST: Type Method Description Amount Payment Check 211094 804.72 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Payment Amount: $804.72 484.98 315.24 4.50 Total: $804.72 9900 07/02 9716 TOTAL 804.72 liner RAmint -11R Printari• OR-711-2007 ProjIct:- Ai/eV Type of Inspection: /— / /1/ \_ / Address: ! V Alit/diVe ()/4( Date Called: -,------, Special Instructions: Date Wanted: , Requester: Phone No: ,4'25- 2— 3S9 0 c. INSPE NO. INSPECTION RECORD Retain a copy with perm: PERMIT NO. CITY I F TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: p)f)( /)t/4/ .00 REINSPECTION E REQUIR . Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suit 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: i LAV■Wiin (AY a 11`c Type of Inspection:A, 1 \.) Address:. , fir ff• U L )11 Date Called: )-F Special Instructions: Date Wanted: a.m. P.m. Requester: Phone No: 1- 1/C l'g Yri INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 . 7 El Approved per applicable codes. Corrections required prior to approval. C MMENTS: Arw !Ar InspectoirMATIMIMI —I $58.7 REINS • CTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: -kr '"'"4. " Project: / / /A.,e V /, ( '�L-� -,, Type of Inspection: 7J,,L A) / Address: / / (/ y A/A 1 ' ,-)/(.." Date Called: Special Instructions: Date Wanted: /Q /// /D7 in, . m . . Requester: Phon No: /2 -3 76 5 - 3C90 INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION \ r� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. COMMENTS: Pj t ; , i , ,,'T , ; i►s e ct r: INSPECTION RECORD Retain a copy with permit p ,/ 45 , . O REINSPECTION FEE'REQUIRED.!�rior to inspection, fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: 7-2'/ 3 j Corrections required prior to approval. Date: ,/r) Projec ice,/ ( e ��pe ( ��� jj of In spe Addr�� i y ,,j ailed: Special Instructions: ` Date Wanted a.m Requester: Phone No: l �,/ INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • 4 P RMIT NO. (206)431 -3670 COMMENTS: 'Inspector:/ f (Date: 7 _ 4 , Approved per applicable codes. Corrections required prior to approval. O $58.00 R ISPECT 0 E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: h/k7( oh, 6 7( "''-'" Type of Inspection:— ....0/ toe r/i-i, Address //0 / 41 Date Called: Special Instructions: Date Wanted: C a.m.. /7 P.m. Requester: Pht:9eNo 7g5 3 7 7 INSPECTI NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IT NO. (206)431-3670 COMMENTS: Approved per applicable codes. El Corrections required prior to approval. rate: S58. INSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: G R c c +1 1.ac fr/ ws z.. Type of Inspection: F7 1" .lam I Address: 37Z 3 .5 Suite #: /Z. C s0°' Contact Person: &,•c C4 P4 Special Instructions: Phone No.: .264 - 293- 52 a Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT D c ; - 2'13 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 TX pproved per applicable codes. n Corrections required prior to approval. COMMENTS: � : L I I v/L . Inspector: S Date: /0/ Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 DEPARTMENTS: Buil i g ision ACTIVITY NUMBER: D07 -243 DATE: 07 - - PROJECT NAME: LINCOLN CENTER HOLDINGS SITE ADDRESS: 1104 ANDOVER PK W Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued Complete Comments: PLAN REVIEW /ROUTING SLIP Fire Prevention Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY I't 1 Planning Division IA j Permit Coordinator n DUE DATE: 07-1 2-07 Not Applicable ❑ No further Review Required DATE: DUE DATE: 08-09-07 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -243 PROJECT NAME: LINCOLN CENTER HOLDINGS SITE ADDRESS: 1104 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 6 -29 -07 Revision # After Permit Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Complete U APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Fire Prevention Structural Incomplete d9 Planning Division Permit Coordinator DUE DATE: 7 -3 -07 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 7 -31 -07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: —S—U7 " Departments issued corrections: Bldg ❑ Fire ❑ Ping PW ❑ Staff Initials: t ER Date: - 1 I `o7 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Lincoln Center Holdings Project Address: 1104 Andover Park W Contact Person: Gregg Percich Summary of Revision: Sheet Number(s): 4 — t Entered in Permits Plus on \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: D07 -243 Steven M. Mullet, Mayor Steve Lancaster, Director CIT RECEIVED LA 'JUL 10 1007 PERMIT CENTF,, Phone Number: 7.©( (42-4 4- i` "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center bye July 9, 2007 Brandon Mills City of Tukwila 6300 Southcenter Boulevard Suite 100 Tukwila, Washington 98188 re: Lincoln Center Holdings 1104 -1114 Andover Park West Tukwila, Washington Project # D07 -243 Brandon, Thank you for your review of the above stated project. Per your letter of Incomplete Application dated July 3, 2007 we respond with the following: 1. Please see the revised sheet A -1. The site plan has been given a scale and the lot dimensions have been added. If there are any questions, or you need any additional information, please call at your earliest convenience. ank yo e Pe rch 603 STEWART ST. SUITE 707 SEATTLE, WA 98101 206 624 -3210 FAX 624 -3243 r g , AIA 112 OLDS STATION ROAD, SUITE 8 WENATCHEE, WA 98801 509 664 -5181 FAX 665 -8750 License Information License JOHNSTI092PA Licensee Name JOHNSON TENANT IMPROVEMENT INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601223621 Ind. Ins. Account Id #3 Business Type CORPORATION Address 1 PO BOX 1149 Address 2 City BOTHELL County KING State WA Zip 980411149 Phone 4254862442 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/1/1991 Expiration Date 10/7/2009 Suspend Date Separation Date Parent Company Previous License JOHNSTI114B0 Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 CBIC SA6988 10/02/2001 Until Cancelled $12,000.00 10/05/2001 #2 CBIC SA6988 07/27/1997 10/02/2001 $6,000.00 #1 CBIC 631601 07/27/1991 07/27/1997 07/27/1997 $6,000.00 Business Owner Information Name Role Effective Date Expiration Date JOHNSON, WILLIAM S 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= JOHNSTIO92PA 09/12/2007 GENERAL NOTES L THE APPROVED PLAN: FROM THE BUILDING Oi JOB SITE. 2. CONTRACTOR SHALL ti BUILDING. REPORT Ai` 3. ALL WORK SHALL MEE 4, ALL NAILING, IF REQ 5 5. ALL WOOD COMING IN RESISTANT)_ . CONTRACTOR DESIGNE PROFESSIONAL STAMP 1. SERVICE WATER PIPES S. WALLS TO BE FIRE STC 9. IF ANY ERRORS, OMISE SPECIFICATIONS OR 0' ARCHITECT IN WRITING PROCEEDING WITH THE SAME. 10. CONTRACTOR SHALL ' FINISHES AND SHALL E FNISHC9. IL TYPICAL DETAILS OR ARE GIVEN. 12. ALL DIMENSIONS SHAL ELEVATIONS, SECTIONS 11 ALL EXIT DOORS TO E SPECIAL KNOWLEDGE. 14. WORK RELATED TO TH MODIFICATION TO THE BY THE GENERAL CON 15. ALL EQUALS TO BE 5U CONSTRUCTION. 16. BIDDER DESIGN WORK I"1. ALL NEW DOORS AND RE -USE EXISTING D00 I8. COORDINATE WITH TEN MECHANICAL AND PLU I. TACTILE SIGNS STATING PROVIDED AT EACH E 20. PROVIDE A TACTILE E 2L MANUALLY OPERATED OPERATION FOR NE U SITE & BLDG. STATS PROJECT ADDRESS GOVERNING CODE TAX ID NUMBER BUILDING TYPE OCCUPANCY TYPE SITE AREA PARKING EXISTING BUILDING AREA PROJECT DESCRIPTION: SHALL NOT BE CHANGED OR ALTERED WITHOUT AUTHORIZATION =ICIAL THE APPROVED PLANS ARE REQUIRED TO BE ON THE !RIFT AND CHECK ALL CONDITIONS AND DIMENSIONS AT THE ' INCONSISTENCIES TO THE ARCHITECT_ LOCAL CODES AND ORDINANCES_ .ALL COMPLY WiTH NAILING SCHEDULE OF THE IBC. :ONTACT W/ CONCRETE SHALL BE PRESSURE TREATED (DECAY ) ELECTRICAL SUBMIT TO BUILDING DEPARTMENT FOR PERMIT. REQUIRED. TO BE INSULATED TO MINIMUM R:5 IN UNHEATED SPACES. 'FED. ON6 OR INCONSISTENCIES APPEAR IN THE DRAIUNGS, -4ER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER OR )F SUCH OMISSIONS, ERRORS, OR INCONSISTENCIES BED WORK, OR ACCEPT RILL RESPONSIBILITY FOR COSTS TO RECTIFY ERIFY CONDITIONS OF EXISTING SUBSTRATE TO RECEIVE NEW RESPONSIBLE FOR PREPARING THEM TO RECEIVE THE NEW $UILDING STANDARDS SHALL APPLY WHERE NO SPECIFIC DETAILS TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, AND DETAILS. OPERABLE FROM INSIDE THE BUILDING WITHOUT KEYS OR , TENANT IMPROVEMENT REQUIRING COORDINATION AND !XISTING CONSTRUCTION SHALL BE INCLUDED IN THIS PROJECT •RACTOR FOR BIDDING AND CONTRACTUAL AGREEMENT_ MITTED TO ARCHITECT FOR APPROYAL PRIOR TO TO SE APPROVED BY ARCHITECT PRIOR TO CONSTRUCTION. 'OCR TRIM TO MATCH EXISTING IN TYPE, FINISH, AND HARDWARE, 5 ON SITE WHERE POS5IBLE ,NT AND DESIGN TEAM FOR LOCATION OF ELECTRICAL , 115ING IF REQUIRED. 'EXIT' AND COMPLYING WITH ALL ICC /ANSI AII1.1 REQ.. SHALL BE IT DOOR PER 1033.11 AND CHAPTER 1 IN GENERAL IT SIGN TO COMPLY WIN ICC AUT. =LUSH BOLTS ARE NOT PERMITTED AND NO MORE THAN ONE LATCHING IS ALLOWED. 1104 ANDOVER PARK WEST TUKWILA, WASHINGTON 2003 IBC W/ WASHINGTON STATE AMENDMENTS 352304 - 9053 -05 v -B SPRINKLED 5 -I EXISTING - UNCHANGED EXISTING PARKING TO Rl t 136,500 SE. INSTALL NEW ACCESSIBLE RAMP TO EXIST OFFICE SPACE WIN NEW ACCESSIBLE PARKING STALLS. VICINITY MAP • 181 m STRANDER MINKLER S SITE 180TH ti ❑ SAXON LEGAL DESCRIPTION Tax Parcel *352304-9053-05 Situate in the County of King, State of Washington STAIR TREADS TIT. 11' 1/2'.l' -0' BY STAIR RISERS AS REQUIRED NOT TO EXCEET T IN HEIGHT TYP. RAILING FILE COPY N. Permit No. Date: 7/0 City of Ttakwila BUILDING DIVISION I' DIA. STL PIPE RAIL, VVxT. SET CONC. MIN S' PROVIDE *4 BARS VERT. 6 12' OL_ IN STAIR WALL 4 *4 CONT. 12' OL_ HORIZ That portion of Government Lot 1 of Section 35 and the Southeast % of the Southeast 1/4 of Section 26, Township 23 North, Range 4 East, W.I., in the City of Tukwila, King County, Washington, described as follows: Beginning at the Northeast corner of said Government Lot 1 of Section 35± Thence North Flo 4-4' 08" West along the North line of said Government Lot I, a distance of 949.49 feet to the True Point of Beginning± Thence South Olo 51' 39' West a distance of 101.44 feet*. Thence North SSo OS' 21' West a distance of 333.00 feet to the East margin of Andover Park West: Thence North Olo 51' 39" East along said East margin of Andover Park West a distance of 109.19 feet± Thence North Olo 4 29" East along said East margin of Andover Park West a distance of 634.01 feet to the North line of Southcenter Industrial Park± Thence South 8So 12' 31' East along said North line of Southcenter Industrial Park a distance of 34.50 feet± Thence Southwesterly along a curve to the left, the center of' which bears South 10o 5 11° East, having a radius of 300.00 feet, an arc distance of 9034 feet± through a central angle of no 15' 14't Thence South Olo 41' 29° West a distance of 54 feet to the True Point of Beg inning Ran review e7 ^: oval is subject to errors and 0mi5SiC41 . A2protv1 c: - 7- :_,11ciaon documents does not authorize the code or ordinance. Reoipt : -'I c7i condlions is acknotviedged: ENISKPAS No et:.z.' 7 be mods ENICT NOTE: �+ViS v Ji r L:',7 as rtc•.•/ and my include i real plan POURED CONC_ STAIR 4 LANDING, PROVIDE *4 BARS 612' O.C. FOR STAIRS 4 *4 BAR m TOE OF EACH TREAD 4 6x6 -W2.9 x W2.9 W.W.M. IN LANDING HANDRAIL TO EXTEND EYOND FIRST RISER, BOTH SIDES RETURN HANDRAIL SACK TO GUARDRAIL TYP. FIN. GRADE NEW CONCRETE STAIR WiTH NEW SIDEWALK RELOCATE OR REPLACE EXISTING LANDSCAPING TO LOCATION OF OLD STAIR REw PLIpNCE APPROV COMPLIAN R . UL 2 2001 Of Tukwila BUI► DIN DWIsI'N PROVIDE SIGN 6 ALL HAND (CAPPED PARKING STALLS INDICATED ON SITE PLAN 1/2'.1'-0' ��. ■ == Pf* 117411911r4 AL- *hum r 4/11 z N � E 0 1' -0' 6 sag =FEUD PIf.= POUF VAN ACCESSIBLE IT -3' :n GRADE H.C.PARKING SIGN 6I -0' WHITE LETTERS 4 SYMBOLS ON BLUE BACKING METAL SIGN, BOLT TO PIPE COLUMN 12' X 16' VAN ACCESSIBLE SIGN AS REQ. PER PLAN 3' DIA. PIPE COL. W/ (2) COATS ENAMEL (WHITE) EMBED 18' iNT CONC. S' DIA. x24" DEEP CONC. FOOTING 13' -0' 5' 0' 5 1' PROVIDE WIDE LANDING AT SPRIINKLER VALVES 0' 13' -0' CHAMFER EDGES, TYP: RAMP (BROOM FINISH) EMBED PIPE I' -0', TYP. 1 4HORIZ e16' OC *4 VERT. 16' (2) *4 CONT. 3 A -I 1/2'.1'-0 26' -0' SLOPE DN e 1:12 MAX SLOPE DN GRADE OR ASHALT, SEE PLAN 22' -0' 1 1 1/2' DIA SCHD. 40 STL PIPE RAILING W/ 6 INTERMEDIATE RAILINGS EQ. SPACED. 42' I-L ABOVE RAMP. TYP. VERT. EQ SPACED MAX COMPACT SITE PLAN 0 SCALE: I' = 50' -0" I' - 5' -0' COMPACT 4 COMPACT SPACES AT 8' - 0 . 32' -0' RAILING @ RAMP NEW CONCRETE RAMP WITH ACCESSIBLE PARKING SPACES EXISTING LANDSCAPING COMPACT ENLARGED PLAN SCALE: I/6" •I 0 COMPACT S' -6' 1 " =1' -0' 9' -0' EXISTING RAMP TO REMAIN 9' -0' 6t. 13' -0' PROVIDE SYMBOL IN ALL HANDICAPPED PARKING STALLS INDICATED ON SITE PLAN =MEW ■ :U: M E now ■ ■ ■■ ■ . ■■■■■ ■L J■■■■ ■t E■ ■■ ■■ I ■ ■■■■ ■N ■ ■ ■■■■ ■■■Eu■I IM■■■NE ■■� ■ ■ ■■ ■i I ■ ■ • ■ U..... . iiii •i� • ■■■■■M ■ ■ ■■ ■ .I ■ ■ ■ ■I i ....E.. ■■ F Fr 1 1 ■■■■■■■ 'm ure, AEI '1 ■ ■ ■ ■ ■■ II ! "iii■k �n0 =�ii _ ■Cm°m■11 ■C: .N, I ■ ■•U■■■11■■� \► \■■■ i ■ ■1 1 ■ ■ ■ ■■ ■Y■■/ 1 \ ■�"�� ■■t \■■■■m■■■/ t .. �1 ■■■L , Ul•••••••• Aak • _ ■ ■t■\ '■MEit►' AU ►�■■ MM. ANNUM= m ■ ■ ■ ■ ■ \- _AI■■■■ER ■ ■M■ ■■ ■U■ ■til••••••illl■■■ _ tr H.C. PARKING SYMBOL RECEIVED CITY TUKWILA. JUL 1 0 ?007 INCOMPLETE LT R# 213 WENATCHEE OFFICE 112 OLDS STATION RD. SUITE B WENATCHEE, WASHINGTON 98801 (509) 664 - 5181 FAX 665 -8750 4879 F- W Z CC I < 0 0_ Z C < O : z< Q d' , r- REGISTERED ARCHITECT REG Tegqjl STATE WASHINGTON DRAWN HL CHECKED GAP DATE 07.09.07 SCALE AS NOTED JOB NO. 06054 FILE: ARCHITECTURAL GROUP RS. SEATTLE OFFICE 603 STEWART STREET SUITE Jul SEATTLE, WASHINGTON 98101 (206) 624 - 3210 FAX 624 -- 3243