HomeMy WebLinkAboutPermit D07-250 - H & W DISTRIBUTION - DEMOLITION AND DEMISING WALLH & W DISTRIBUTION
18205 ANDOVER PK W
D07 -250
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Phone:
Contact Person:
Name:
Address:
Phone:
City ,A Tukwila
3523049119
18205 ANDOVER PK W TUKW
H & W DISTRIBUTION
18205 ANDOVER PK W , TUKWILA WA
LA PIANTA LLC
PO BOX 88028 , TUKWILA WA 98138
BARRY BENNETT
PO BOX 88028 , TUKWILA WA 98188
206 396 -2012
Contractor:
Name: LA PIANTA LLC
Address: PO BOX 88028 , TUKWILA WA 98138
Phone: 206 -575 -7000
Contractor License No: LAPIAL *008J8
DEVELOPMENT PERMIT
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
DESCRIPTION OF WORK:
TENANT IMPROVEMENT: CONSTRUCT NON - STRUCTURAL DEMISING WALL AND INETERIOR DEMOLITION
(NON- STRUCTURAL)
BLANKET PERMIT NO. 06- 001 -SPA
Value of Construction: $25,920.00
Type of Fire Protection: SPRINKLERS
Type of Construction: VB
doc: IBC -10/06
* *continued on next page **
D07 -250
Permit Number:
Issue Date:
Permit Expires On:
Expiration Date: 04/01/2008
D07 -250
08/09/2007
01/23/2008
Fees Collected: $825.38
International Building Code Edition: 2006
Occupancy per IBC: 0011
Printed: 08 -09 -2007
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
City a..Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: D07 -250
Issue Date: 08/09/2007
Permit Expires On: 01/23/2008
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Signature:
Print Name:
Date: 8-9- D - 7
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perfor Lance of work. I am authorized to sign and obtain this development perfiit. 7
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IBC /06 D07 -250 Printed: 08 -09 -2007
Parcel No.: 3523049119
Address:
Suite No:
Tenant:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
18205 ANDOVER PK W TUKW
H & W DISTRIBUTION
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All wood to remain in placed concrete shall be treated wood.
7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
D07 -250
ISSUED
07/05/2007
08/09/2007
10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum
distance of 4- inches shall be maintained above the controls with the strapping.
12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206 - 431 - 3670).
14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Cond -10/06 D07 -250 Printed: 08-09 -2007
15: ** *FIRE DEPARTMENT CONDITIONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4-3, 4-4)
23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
27: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
28: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
doc: Cond -10/06
D07 -250 Printed: 08-09 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
30: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3)
31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2051)
35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
39: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
40: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
* *continued on next page **
D07 -250 Printed: 08-09 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10/06
NtiC�
Date:
D07 - 250 Printed: 08 -09 -2007
PROPERTY OWNER:
ra
Phone No: ( )
Address:
lox wad i �k w, /k.
9�- e wA
City/State /Zi
7.;-/k .v,10. WA ( 4 ,- 10
CONTRACATOR: La "Pia ...40. L.GC
is aggro
Phone No: ( ) 39(v-oZOt0-
Address: 10 7 . 1 .7 k. 7
%
r _ s _
City /State /Zip: 7Uk,,vt (&. ovA -/ ps
WA State Contractor's License No.: 44 priqL 0 ....... 5 . 8 .
Expiration Date: /mil / oi-
ARCHITECT: &�� MnPIIP- a f(SSx1Q
Phone No: (a,) 3Rs .2%-s3
Address:
1SO Lakes t t,
9 181 it
City/State /Zip: 56affi£ GJA Q--(
WA State Architect's License No.: .567 C
Expiration Date:
Signature:
ra
Organization: LA "P L C
ST l( . Pr 1
Print Name:
is aggro
Be M
/ T
Phone No:
ate' 3.9( - cola_
Address:
P. 0'
8�a�
City /State /Zip
/v kw ,I6- 6.44
9 181 it
CITY O UKWILA
Department of Community Development
Building Division - Permit Center
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431 -3670
Blanket Permit Tenant Improvement Application
ALL APPLICATIONS MUST BE FILLED OUT COMPLETELY
(Shaded area for Office Use Only)
PLAN REVIEW NUMBER
BLANKET PERMIT AGREEMENT. NO:
DESCRIPTION
Building Surcharge
AMOUNT
1411
4.50
RCPT #
1)1-- 012
DATE
01-144-
Building Permit Fee
Plan Check Fee
Site Address: IS-9z6- ,4aovP_ c` TiAr k kie\f
Floor: GrootACk Suite Number: iv /Jq
Project/Tenant Name: 7/4-00 '[7►��r�{�u1'l��
9� Value of Construction: $ nZs 9(90 .00
Assessor Account No.: 3 SR.311-9 /19
Type of Work: ®. Tenant Improvement PS1, Interior Demolition ❑ Other:
Describe work to be done: Cov�St(WC�' inv S-}-ruC +vu0.1 o�P►M►S l h` Wag n�
AA o'kevv.o(, hhr. �inoti.- C +m∎C4um.) d
Building Type: U'g 5 4.k lec'P4 Building Use (office, warehouse, etc): Gv .re ( �s e-
Nature of Occupancy (printing, manufacturing, etc): Cvoet
Square Footage: Entire Building: `/g; 3 8 Construction Area: / ! SF"Tenant Space: 33 to
Will there be a change in use? ®, No ❑ Yes If "yes ", explain:
Will there be rack storage? ❑ No ®, Yes (Sepe•o.k t`w 4 )
Existing Fire Protection: ®, Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? QJ, No ❑ Yes
If "yes ", please explain:
Will there be ANY structural work? E,, No ❑ Yes
If "yes ", please describe:
I hereby certj that I have read and examined this application and know the same to be true and correct, and I am authorized under
Blanket Permit Agreement No. 061- 001- BP to apply for and obtain this permit.
See reverse side of application for specific plan submittal requirements and information.
Date application accepted: 04.
Date application expires:
04/24/00
This tenant improvement application may be submitted for non - structural interior construction which is authorized
under an existing approved blanket permit agreement. It is the responsibility of the applicant to be aware and
comply with all the terms and conditions as set forth in the agreement.
The work is limited to that shown on the plans as submitted with this application, and such work is limited to non-
structural interior construction only. The following work is not covered under the blanket permit process and
separate approvals, permits and inspections are obtained through the applicable agencies.
ELECTRICAL - Department of Labor and Industries (248 -6630)
PLUMBING/GAS PIPING - King County Health Department (296 -4722)
FIRE PROTECTION - City of Tukwila Fire Department (575 -4404)
MECHANICAL - City of Tukwila Permit Center (431 -3670)
RACK STORAGE - City of Tukwila Permit Center (431 -3670)
BUILDING PERMIT APPLICATION
GENERAL INFORMATION
Submittal - Application and plans must be complete in order to be accepted for plan review. Make
sure to fill out the application completely and follow the plans submittal checklist which follows. Handouts are
available at the Permit Center which provide more in -depth detail on preparing the submittal.
Authorized Agent - The applicant must be an authorized agent as identified in the Blanket Permit.
Fees - The permit fees are based on valuation of construction as declared by the applicant on the application, and
shall include all the work to be covered under the permit. The valuation will be reviewed and is subject to revision
by the Building Official to insure compliance with current fee schedules. To obtain a fee schedule, contact the
Permit Center at 431 -3670.
SUBMITTAL CHECKLIST
I!L! C pleted Building Permit Application
Attachment #1 - Architects Statement
12( Three (3) sets of construction drawings, which include:
❑ Site Plan, showing:
O Building location on property
O Adjoining public rights -of -way
O Parking layout
O Location of tenant space or area of work within building
O Overall dimensions of building
O Overall dimensions of tenant space, or area or work
O Name of each common wall tenant(s) and type of business or occupancy
❑ Floor plan of entire floor or tenant space that the work is taking place, showing:
O Tenant space layout with use of each room labeled
O All exit doors, corridors and egress patterns
O All new walls, existing walls and proposed walls (provide construction key)
O All other proposed construction
❑ Construction details
O Construction key
O Cross sections showing wall construction and method of attachment, floor and ceiling
O Reflected ceiling plan (if applicable)
❑ Miscellaneous
O 6" x 8" blank space provided on lower right hand corner of each page of plans (for use by the plan
checker)
O Title block on each sheet, identifying:
• Project name
• Company job number (if applicable)
• Site address
a Blanket permit agreement number
• Architect, address and phone number
O Each sheet of plans stamped by a Washington State licensed architect
O Minimum sheet size 18" x 24"
O Plans must be drawn to scale and clearly dimensioned Drawings shall be prints which are clearly
readable (original pencil or highlighted drawings are not acceptable.)
Permit Fees (plan check fee, building permit fee and state building surcharge)
11/01/99
Blanket Permit Agreement Information
Is any part of the work proposed under this application include
structural work of affect structural components of the building?
0 Yes
lVNo
If yes, has the structural work been authorized by the Tukwila
Building Official to be included in this application?
0 Yes
0 No
Does the proposed work comply with the requirements of Chapter
10 of the Uniform Building Code (1997 Edition)?
Yes
0 No
If no, please explain:
Street Address:
13fl La ke,i cit.,
SITE ADDRESS
City /State/Zip: &. f.{e (Am
9J-/
Will any special inspections be required per Chapter 17 of the
Uniform Building Code (1997 Edition)?
0 Yes
(4" No
If yes, list specific inspections:
As a result of this proposal, does the parking meet the
requirements of the Tukwila Zoning Code parking requirements?
�es
0 No
If no, please explain deficiency:
Architect/Engineer Stamp:
Architect/Engineer Signatur .
(i)‘.6 ��
Print Name: � �„1 1�00
T
BLANKET PERMIT
AGREEMENT NO.:
8695 ,. - :, t
r r
"'
SLATE OF MSN!!�O,,,N
`'�
Name: ZaKCe, Aqu2 I Iv- amDA
A-ssockkles
Business Phone:
131g'
Street Address:
13fl La ke,i cit.,
SITE ADDRESS
City /State/Zip: &. f.{e (Am
9J-/
PLAN
REVIEW NO.:
1 _ b
PROJECT NAME/
TENANT: ft t IA)
D}sk't bu i-tov
BLANKET PERMIT
AGREEMENT NO.:
Q(`)- ��
�
COMPANY
JOB NO.:
0-7
-23
131g'
SITE ADDRESS
1 Laos /q ►ioveE` k ()Vint
j/
Wm
9�J8g
CITY OF TUKWILA
Department of Community Development
Building Division - Permit Center
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431 -3670
Blanket Permit Agreement
03/22/00
Blanket Permit Architect Statement
Tenant Improvement Application
Attachment '( - Architects Statement
"X"
REQUIRED INSPECTIONS
DATE
APPROVED
INSPECT
INITIALS
PLANS
DATE
DATE(S)
CORRECTION NOTICE ISSUED
X
1.
Framing
n
win
•
2.
Insulation
3.
Suspended Ceiling
4.
Wallboard Fastening
?(
6
'i NA(.
DO NOT PROCEED BEYOND THIS POINT UNTIL THE BUILDING PERMIT IS ISSUED.
PERMIT MUST BE PICKED UP WITHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY.
Plan Review No.: .WI" 1;1)
Date Issued: 0.4.,
0 I O1,
Blanket Permit Agreement No.: _Doi- 3n
Project Name /Job No
: 4+63 tD
A- _...,3 I- 13 I E
Site Address: l X ° A Inok3Ve r` 1 A- (Ai elk - 17;I: w c teN w,
n
win
CITY C
Department of Community Development
Building Division - Permit Center
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431 -3670
Blanket Permit Agreement
Tenant Improvement Temporary Inspection Card
CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (431 -3670)
(Have Plan Review number, Blanket Permit Agreement number, project name and site address read
CONTRACTOR/APPLICANT BEGINS WORK AT THEIR OWN RISK
PER THE TERMS OF THE BLANKET PERMIT AGREEMENT.
INSPECTIONS
1. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in
place.
2. INSULATION - After framing approval, but before insulation of wallboard. Baffles must be installed to keep attic
ventilation points clear.
3. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing.
4. WALLBOARD FASTENING - Prior to taping (See UBC Chap. 25 and Table 25G).
5. PLAN CHECK INSPECTION - Immediately after the Tenant Improvement Permit is picked -up by the applicant. Work
may not proceed until the City Inspector delivers the plans and new inspection card to the site. This inspection should
be scheduled at the Permit Center when the permit is obtained.
• Construction will not proceed past required inspections.
• The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the
permit is ready. Failure to do so may result in a stop work order.
• Construction may not deviate from that shown on the plans as submitted at time of application.
• All corrections shall be made within three (3) days of notification by Building Inspector.
• No more than 30 days shall elapse between the last required inspection and the "Building Final."
• Unauthorized occupancy and /or use of the remodeled area shall not occur until the Building Inspector completes the
"Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued.
• The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a
building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify
for consideration under the blanket permit process.
• The following work is not covered under the blanket permit process. This work shall not start until approvals and
permits are obtained through the applicable agencies, under their normal process:
Electrical Department of Labor and Industries (248 -6630)
Plumbing /Gas Piping King County Health Department (296 -4722)
Fire Protection City of Tukwila Fire Department (575 -4404)
Mechanical City of Tukwila Permit Center (431 -3670)
Rack Storage City of Tukwila Permit Center-(431 -3670)
THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BYA
PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED.
11/01/99
Blanket Permit Inspection Card
Parcel No.:
Address: 18205 ANDOVER PK W TUKW
Suite No:
Applicant: H & W DISTRIBUTION
Receipt No.: R07 -01300
Initials: JEM
User ID: 1165
Payee: SEGALE PROPERTIES
ACCOUNT ITEM LIST:
Description
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
000/322.100
000/345.830
000/386.904
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 54100 825.38
Account Code Current Pmts
497.50
323.38
4.50
Total: $825.38
Permit Number: D07 - 250
Status: PENDING
Applied Date: 07/05/2007
Issue Date:
Payment Amount: $825.38
Payment Date: 07/05/2007 03:24 PM
Balance: $0.00
0024 07/05 9716 TOTAL 825.38
doc: Receipt-06 Printed: 07 -05 -2007
Project:
A� 4 '41 J/ 7/ , J7/ /J'U
Type of Inspection:
7 7
Addr �
& 2c 5 / �' Lr cV r r' vi/
ate Called:
Special Instructions:
Date Wanted:
7 -Z 7'O7
�i{
P.m.
Requester:
Phgne No:
C OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS
p Yf /
Inspect
]cam I Dat - z
.00 REINSPECTION : REQUIRED. Prior to inspection, fee must be
id at 6300 Southcenter :lvd.. Suite 100. Call the schedule reinspection.
eipt No.: 1Date:
INSPECTION RECORD
Retain a copy with permit
(20.) 1 -3670
Project:
/7 , t 6 Gti
' -I '
Type of Inspection: -
F C.,
Addros:
, ; 2 0 ,
. „-/Pc.L)
Date Called:
-----
Special Instructions:
(7/9 / 7,, ./.- /if , 1 iz
Date Wanted:
7 - /3
- D — 7
Ca
p.m.
Requester:
Phone No:
, ? Q/?
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT
CITY OF TUKWILA BUILDING DIVISION Al /
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
O REINSP7 ON FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 S • thcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
'Date:
.••4 44 - ' ,• Pt.
Project: / g z o 5 / 9/14) p2or,
Type of Inspection:
/ /G t/ J
Address: /, z' S f1r',g
Suite #:
Contact Person:
et-e-.-ii
Special Instructions:
Phone No.:
Zc'C - 374. Z c-JZ...
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
, CITY OF TUKWILA FIRE DEPARTMENT
[pproved per applicable codes.
Word /Inspection Record Form.Doc 1/13/06
D07 - 2Sb
PERMIT NUMBERS
rk East, Tukwila, Wa. 98188 206 - 575 -4407
n Corrections required prior to approval.
COMMENTS:
) 1)..J-1--1 1.5 . ?, 1.2 //
Inspector: t d("/ 61
Date: 7) ?5 0
Hrs.:
tt 21 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
R j t y of Tukwila Finance Department. Call to schedule a reinspection.
T.F.D. Form F.P. 113
DEPARTMENTS:
B ng "Division
Public Works
Complete
Comments:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28-02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D07 - 250 DATE: 07 -05 -07
PROJECT NAME: H & W DISTRIBUTION
SITE ADDRESS: 18205 ANDOVER PK W
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping El PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route V Structural Review Required
REVIEWER'S INITIALS:
Approved with Conditions
`'
Fire Prevention
Planning Division
❑ Permit Coordinator
No further Review Required
DATE:
DATE:
DUE DATE: 07 -10-07
Not Applicable ❑
Li
DUE DATE: 08-07-07
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
LAPIAL *008J8
Licensee Name
LA PIANTA LLC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602023533
Ind. Ins. Account Id
PARTNER/MEMBER
Business Type
LIMITED LIABILITY COMPANY
Address 1
PO BOX 88028
Address 2
City
TUKWILA
County
KING
State
WA
Zip
981382028
Phone
2065752000
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
4/28/2000
Expiration Date
4/1/2008
Suspend Date
Separation Date
Parent Company
Previous License
LAPIALP055MZ
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
SEGALE, MARIO A
AGENT
01/01/1980
Bond
Amount
SEGALE, MARIO A
PARTNER/MEMBER
01/01/1980
6115146
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#2
SAFECO
INS CO
OF AM
6115146
04/01/2002
Until
Cancelled
$12,000.00
03/28/2002
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= LAPIAL *008J8 08/01/2007
•
EXISTING OPENING —\
IN CONCRETE
PANEL
SECTIONAL DOOR —\
WEATHERSTRIPING
ON POOR JAMB
EXISTING • -' ' AREA
NO UiORK R THIS
PERMIT
EXISTING FULL HEIGHT
WALL TO REMAIN EXCEPT
AS NOTED
I-I AND W DISTRIBUTI
336' -0"
REMOvE CIS BAY CF
EXISTNG FILL HE1G .IT
WALL FROM COLUI'TI
TO COLUtt1
EXISTNG Ps�QTITIONS����
TO EE RB i
•
CO SLIP JOINT DETAIL
EXISTING FULL HEIGHT
WALL TO BE REMOVED
NEW FULL HEIGHT
DEMISING WALL
PER IIETAILS
EXISTING WOOD PURLIN
(4xI6 VERIFY)
I A 1
•
I
. 3 • I f
EXISTING P RTITICNS
1 AND TO I
i BE REV
f
1
R I• 0vE EXIST ICs STOREFRONT
IN THREE LOCA T t0{ I5 AND
aNSTALL UPWaQD ACTING
P TAL SERVICE DOORS.
TFESE LOCATIONS LERE
ORIGICNALLY SERY,CE DOORS
2x4 KICKER TO NEXT PURLIN
AT I/3 POINTS BETWEEN COLUMNS
4 "X8 "X 16 GA DEEP LEG
TOP TRACK WITH '8WOOD
SCREWS • EACH 24"
•
VERIFY STUD SIZE
8" X 20 GA METAL STUDS s
24" O.C. (PER MANUF.) WITH
5/8" GWB EACH SIDE. FIRE TAPE
ALL JOINTS.
ATTACH TO
ROOF STRUCTURE
PER SLIP JOINT
5/8" GM ON METAL FRAMING
BOTH SIDES
8005200 -33 20 GA
AT 24" O.C.
800 TI25 -54
(8 "X11/4 "X 16 GA TRACK)
W/ HILT! POWDER
FASTENERS ( 0.111" DI. X 11/4 ")
AT 16" O.C. TYP.
EXISTING PARTITIONS
AND MEZZANINE
STRUCTURE TO BE
REMOVED
ACE FOR LEASE —
ts . KIK THIS PERMIT
I
DEMISING WALL
BUILDING FLOOR PLAN
Do Iso
f ..
RFC
05NM7