Loading...
HomeMy WebLinkAboutPermit D07-285 - CUSTOMER RESEARCH - TENANT IMPROVEMENTCUSTOMER RESEARCH 565 ANDOVER PK W D07 -285 Parcel No.: 2623049144 Address: 565 ANDOVER PK W TUKW Suite No: Tenant: Name: CUSTOMER RESEARCH Address: 656 ANDOVER PK W , TUKWILA WA City,,.,1 Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: SOUTHCENTER CORPORATE SQUARE Address: 150 CALIFORNIA ST , SAN FRANCISCO CA 94111 Phone: 206 575 -3080 Contact Person: Name: TAMARA GENZALE Address: 635 ANDOVER PK W, STE 107 , TUKWILA WA 98188 Phone: 206 575 -3080 Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Phone: 206 - 361 -2989 Contractor License No: DPINCGC066BU DESCRIPTION OF WORK: TENANT IMPROVEMENT: CARPET, PAINT, DEMO AND NEW WALLS doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D07 -285 Issue Date: 09/04/2007 Permit Expires On: 03/02/2008 Expiration Date: 01/31/2008 Value of Construction: $25,000.00 Fees Collected: $804.72 Type of Fire Protection: SPRINKLER/AFA International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 D07 -285 Printed: 09 -04 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City a, .Tukwila `.. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D07 -285 Issue Date: 09/04/2007 Permit Expires On: 03/02/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or performance of work. I am authorized to sign and obtain this development permit. l Date: ` ` RD —1 7 Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC-10 /06 Il InD in vy\i 1 I w 007 -285 Printed: 09 -04 -2007 Parcel No.: 2623049144 Address: Suite No: Tenant: 565 ANDOVER PK W TUKW CUSTOMER RESEARCH 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -285 ISSUED 07/31/2007 09/04/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the doc: Cond -10/06 D07 -285 Printed: 09 -04 -2007 following concerns: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 15: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Maintain fire extinguisher coverage throughout. 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: In Group B and M occupancies, the minimum clear aisle width shall be determined by the occupant load served, but shall not be less than 36 inches. (IFC 1013.4.1) 24: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 26: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) doc: Cond -10/06 D07 -285 Printed: 09 -04 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 30: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 31: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 32: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 33: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 34: All interior demo debris must be removed prior to demo of the automatic sprinkler system. Contact the Tukwila Fire Prevention Bureau at 206/575 -4407 for an inspection of the building prior to shut down of the automatic sprinkler system. 35: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 514. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 38: ** *PUBLIC WORKS DEPARTMENT CONDTIlONS * ** 39: Applicant shall apply for a separate Public Works permit to install required domestic water RPPA. This backflow shall be in place, tested and backflow PW permit finaled prior to final sign -off of this Tenant Improvement permit. doc: Cond -10/06 * * continued on next page ** D07 -285 Printed: 09 -04 -2007 Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. clAcOn r\o W' 1 sW doc: Cond -10/06 D07 -285 Date: ordinances governing or local laws regulating Printed: 09 -04 -2007 Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www.ci.lukir ila. wa. us Name f V.(. tlak2ctie, 1704-2S5 Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office e only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** �) King Co Assessor's Tax No.: 2.(92 Site Address:51 V nn`n 11 C /n�N � -� ?cwt. W e Tenant Name: l bike ; 12,1Z `ih Property Owners Name: ��)CV 1 CSAQ,1, ' nn ,{ a Mailing Address: V3S. WAA L �, 5 t ti le- 1 ( h'%J f t ( i,U 4% j0 State Zip Sut1e I� E -Mail Address: fiOC,{ \ it - ( C GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: — b E -Mail Address: Q:\Applications\Forns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Suite Number: p Floor: New Tenant: Yes ❑ ..No LL el City CONTACT PERSON - who do we contact when your permit is ready to be issued City Fax Number: Company Name: Mailing Address: city Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Day Telephone: 2D6 S1S a v - State Zip ZDo I e l State Zip Company Name: Matu� na g Mailing Address: 222 S AAre -t'f e C. emtu voa. l- , -e 1 Jh i t A CL4t Day 2 �` State Zip Contact Person: L Day Telephone: � L 7 � � �O 4 1 . 4 � �� E -Mail Address: '. 4t)ht 001-.1,12- a Mart/ sje - Cat x lumber: -I 0 ' I t ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Page 1 of 6 State Zip Will there be new rack storage? ❑ Yes Q: Applications\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ 7g;01) V Existing Building Valuation: $ S ope of Work (please provide detailed i. formation): tell aM Q fl . No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ' No If "yes ", explain: FIRE PR TECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing ' Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor "! 3 1 X3 V — r ��/� a""�lT1 2 Floor 10,23 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Will there be new rack storage? ❑ Yes Q: Applications\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ 7g;01) V Existing Building Valuation: $ S ope of Work (please provide detailed i. formation): tell aM Q fl . No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ' No If "yes ", explain: FIRE PR TECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. I L _ I / /.dI:/ BUILDING OR OR A ED AGENT: Signature: Print Name: Mailing Address: Date Application Accepted: I �I 01- Date Application Expires: Staff Initials: i Q: Wpplications 'Forms- Applications On Line.3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: 7/4 h Day Telephone: t i 16 pV fo- era hth 14 kik ale City State Zip Page 6 of 6 Parcel No.: 2623049144 Address: 565 ANDOVER PK W TUKW Suite No: Applicant: CUSTOMER RESEARCH Payee: SOUTHCENTER CORP SQUARE TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Receipt No.: R07 -01866 Payment Amount: $489.48 Initials: WER Payment Date: 09/04/2007 10:13 AM User ID: 1655 Balance: $0.00 Amount Payment Check 1432 489.48 Account Code Current Pmts 000/322.100 484.98 000/386.904 4.50 Total: $489.48 Permit Number: D07 - 285 Status: APPROVED Applied Date: 07/31/2007 Issue Date: 2349 0 0710 TOTAL 489.48 doc: Receiot -06 Printed: 09 -04 -2007 Parcel No.: 2623049144 Address: 565 ANDOVER PK W TUKW Suite No: Applicant: CUSTOMER RESEARCH Receipt No.: R07 -01544 Payee: TAMARA K. GENZALE TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 07/31/2007 11:53 AM User ID: 1165 Balance: $489.48 Amount Payment Check 2267 315.24 Account Code Current Pmts 000/345.830 315.24 Total: $315.24 Permit Number: D07 - 285 Status: PENDING Applied Date: 07/31/2007 Issue Date: Payment Amount: $315.24 0884 07/31 9710 TOTAL 315.24 doc: Receiot -06 Printed: 07 -31 -2007 Project: . /e ,, 17, i A,..,{ Type of Inspection: /7.,0 ,- L.e, e Address: Date Called: Special Instructions: - -- Date Wanted: a.m. Requester: Phone No: 7— - ---i INSPECTION RECORD Retain a copy withyermit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Approved per applicable codes. ❑ Corrections required prior to approval. 0 $58.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: ✓/7 s..___ /vl r ` S-C C t /2.4.--7 iJ O'I-c- ,S0 /. -- s A, , ,== j7d A ..1-7 G /> .-.//l-- , 4 q. , -7 / , i' / ! - ' (t r, ,' i e/ ie--sisA /mil , 'A l Fi , ... f e/Ze I ..-- i leA, ,5- , /.5' / , ,. m,5" ,-.4e.-3-,-#,7 ° h z , 4, 2- -, , — 7iA /4 c43 0 +3 ,17 5 /9 f,4 f' l /,,,« , 4 ,Z S, w i / arrrs/ aii) 4) la w Date Wanted: .i . / Grl4r0 hOO ..✓_ 1-C - 4 `�.R/ � Pr0,Oct: ( iti ;' c4,1_9 Type of Inspection: Fi Nh / J Address: At ,,5 C cA—e ? K G.) Date Called: Special Instructions: Date Wanted: a.m. b –t o C 1 Requester: Phone No: 2 - (1Z 3 ' ?7G INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Dr) _ PERMIT NO. (206)431 - 67 Approved per applicable codes. JJ Corrections required prior to approval. (Inspector:/ ❑ $58.00 REINSPECT! O'f FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: 1 � I � 'Date: Project: _ . ' '_ 1 / Type of Inspection: ./ .._ Address: �" SAS ,4-P e - sate ailed: Special Instructions: Date Wanted: 7)_ (1.T) m. Requester: Phone No: 2c - 4 iz3 -z q t INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 pproved per applicable codes. Corrections required prior to approval. COMMENTS: El $58.00 REINSPECTION REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter lvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: PERMIT NO. F-� (206)431 -3670 Proj t: 0 / Type of Ins • ection: V Address: 4 p� Date Called: � 5�� Spec aa nstructi ns: Date Wanted: .--70-- 27 4 m. Requester: Phone No: 7-466 1 -/ - 3--07 , 5 F1 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Mr El $58.00 RE SPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No. : !Date: WSJ INSPECTION RECORD may,, Retain a copy with ermit /--�7� 5 � INSPE c NO. pY p PERMn,NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: C u 5 //) (_lz..PA✓R Cv Type of Inspection: v 1 5 . P 4 2 2 / 5 JA- 7-, v Address: 5 b S" 4_ io. ki I Suite #: :Contact Person: L i G� �_ Y Special Instructions: Phone No.: Monitor: Needs Shift Inspection: Y Sprinklers: i Fire Alarm: Y Hood & Duct: oci Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Fl Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 n Corrections required prior to approval. COMMENTS: L Inspector: / Lt Date: /o /i 6-7 Hrs.: I 80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: `t c c.. gTt) r✓" D� ' / P c g_ `'V` -- Type of Inspection: u L�r,Le <..�. c�1j /, S Address: S� S- Suite #: ,q , P. Contact rsofi: / /)5 Permits: Special Instructions: Phone No.: Needs Shift Inspection: r' Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER ri Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 7 a� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: Inspector: Date: / 16 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: Cvs7ZrY1 - n. n 14 cr vC! Type of Inspection: V►riL Ac,nipr■ Address: 51:2S P ti I Suite #: lo i Contact Person /_.t -e) if VV/A/N Special Instructions: Phone No.: 206 - Y 7 3 -- Z7b o Needs Shift Inspection: y Sprinklers: y Fire Alarm: ` I Hood & Duct: F.) Monitor: Pre -Fire: Permits: Occupancy Type: -. 6 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575- -Approved per applicable codes. - Dog -2 F- 221, . PERMIT NUMBERS I I Corrections required prior to approval. COMMENTS: p ;r /lam r <c Inspector: j j y Date: /d /y /p q Hrs.: 7 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. 8116 6 f, 1.11 Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 August 10, 2007 Tamara Genzale 635 Andover Pk W, Ste 107 Tukwila WA 98188 Dear Ms. Genzale, Building Department: Public Works Department: Sincerely ) 44 811 Z arshall hnician City of Tukwila RE: CORRECTION LETTER #1 Development Permit Application Number D07 -285 Customer Research — 565 Andover Pk W If you have any questions, please contact me at (206) 431 -3760. encl File No. D07 -285 P:\Pemtit Center\Correction Letters\2007\D07 -285 Correction Ltr #1.DOC jem Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Public Works Departments. At this time the Fire and Planning Departments have no comments. Allen Johannessen at 206 433 -7163, if you have questions regarding the attached memo. Joanna Spencer at 206 431 -2440, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Tukwila Building Division Allen Johannessen, Plan Examiner Date: August 6, 2007 Project Name: Customer Research Permit #: D07 -285 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please identify number of occupants for this tenant space. 2. Show square footage for each space and show dimensions. 3. Identify emergency lighting. (2006 IBC Section 1006) 4. New plumbing for the break room sink shall require a separate plumbing permit. Provide note on plan and apply for permit. Should there be questions concerning the above requirements, contact the Building Division at 206-431- 3670. No further comments at this time. (P:Joanna/Comments 1 D07 -285 PW) PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards DATE: August 1, 2007 PROJECT: Customer Research Tenant Improvement 565 Andover Park West REVIEW #: 1 PERMIT NO: D07 -285 PLAN REVIEWER: Contact Joanna Spencer at (206) 431 -2440 if you have any questions regarding the following comments. 1) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The City has determined that the subject building has deficiencies on domestic water service line only. a) Domestic Water Service A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the existing 1.5 "permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works strongly recommends a power supply for the freeze protection enclosure. Please specify on your plan backflow size, manufacturer, and model number and submit a cut sheet of the proposed device. I have enclosed Development Bulletin C5, which spells out design and installation requirements for cross connection control. The Public Works Director will withhold issuance of this Tenant Improvement permit until the backflow issue for domestic water is resolved or the Permit Center receives plans for items RPPA installation. Applicant can post a bond in the amount equal to 150% of the design, installation, and testing cost of subject device, together with a letter stating the installation by a certain date. A separate letter was mailed to the property owner. David McPherson - Re: Backflow at 565 Andover Park West From: Bryan Still To: David McPherson Date: 08/01/2007 3:01 pm Subject: Re: Backflow at 565 Andover Park West Hi David, They are o.k. with fire and irrigation AMR. Need RPPA on 1 1 /2" domestic. Thanks Bryan »> David McPherson 08/01/2007 11:39 am »> Bryan, Please let me know if backflow needs to be updated for Building at 565 Andover Park West. Ref. TI permit no. D07 -285. Thank you. Dave PERMANENT FILE COPY ACTIVITY NUMBER: D07 -285 DATE: 08 -22 -07 PROJECT NAME: CUSTOMER RESEARCH SITE ADDRESS: 565 ANDOVER PK W _ Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued Public Works � /.! 01 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Structural Review Required DATE: DATE: Planning Division ❑ Permit Coordinator DUE DATE: 08 -23 -07 Not Applicable ❑ No further Review Required APPROVALS OR CORRECTIONS: DUE DATE: 09 -20 -07 Approved ❑ Approved with Conditions IA Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D07 -285 DATE: 07 -31 -07 PROJECT NAME: CUSTOMER RESEARCH SITE ADDRESS: 565 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPA TMEN S: t Cf� Bu 'din >; Division Public orks DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP PERMIT COORD COPY . Structural Review Required nit Bldg Ni /(►J (71'6b* Fire Prevention Structural DUE DATE: 08-02-07 Not Applicable ❑ No further Review Required DATE: DATE: ii/14 64 P al' nning Division Permit Coordinator ❑ DUE DATE: 08 -30-07 Not Approved (attach comments) �✓ Fire ❑ Ping ❑ PW2 Staff Initials:, Date: g 1 22101 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Customer Research Project Address: 565 Andover Pk W Plan Check/Permit Number: D07-285 Steven M. Mullet, Mayor Steve Lancaster, Director Contact Person: - fig WWII 601 le Phone Number: 2 4 • c1 Q � • 4bb2 Summary of Revision: km (` 0 V \ (01 h S p‘ ' iG VO•i' R-vew ArneI GI V1 W echaVrIct t Covr0v1' iovl L MG) 61192110M 1( view lov mot l ow 1;i Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisi Received at the City of Tukwila Permit Center by: -)? -0 Entered in Permits Plus on \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: R-N4 t IVED cm OF TUKWILA AUG 22 20x1 License Information License DPINCGC066BU Licensee Name D P INC GENERAL CONTRACTORS Licensee Type CONSTRUCTION CONTRACTOR UBI 601515833 Ind. Ins. Account Id #4 Business Type CORPORATION Address 1 19909 BALLINGER WAY NE Address 2 City SEATTLE County KING State WA Zip 98155 Phone 2063612989 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/31/1994 Expiration Date 1/31/2008 Suspend Date Separation Date Parent Company Previous License DODSOPI101JB Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #4 CBIC SA6377 01/31/2002 Until Cancelled $12,000.00 01/09/2002 #3 CBIC SA6377 01/31/1998 01/31/2002 $6,000.00 #2 CBIC SA6377 01/31/1997 01/31/1998 $6,000.00 Business Owner Information Name Role Effective Date Expiration Date DODSON, WILLIAM PRESIDENT 01/31/1994 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= DPINCGC066BU 09/04/2007 • • 6 I GENERAL NOTES UPLAND D N MIDLAND [ STRAIR BLVD. VICINI_MAP OCCUPANT LOAD: 3,816 SF @ 1:100 = 38.16 OCCUPANTS 1 EXIT REQUIRED, 2 EXITS PROVIDED �± 2,148 SFI CONTRACTOR SHALL PROVIDE ALL WORK AND MATERIALS IN ACCORDANCE WITH APPLICABLE CITY, COUNTY, STATE AND FEDERAL BUILDING AND FIRE CODE& CONTRACTOR SHALL BE GOVERNED BY ALL OONORIONSAS INDICATED N THE CONTRACT DRAWINGS & SPECIFICATIONS. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCES BEFORE PROCEEDING WITH WORK CONTRACTOR SHALL OBTAIN ALL PERMITS AND APPROVALS. B/S INDICATES 'BUILDING STANDARD' AS PROVIDED BY LANDLORD DRAWN AND4OR SPECIFIED IN BUILDING CONTRACT DOCU ENT& IF NOT SPECKED. CONTRACTOR SHALL SEE ADJACENT SPACES FOR EXISTING EXAMPLES AND CONDITIONS. WALLS AND CEILINGS TO BE @DEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS ALL MECH AMCAL, ELECTRICAL. PLUMBING. FILE ALARM AND SPRINKLER AND SECURITY DESIGN SHALL BE PERFORMED BY THE CONTRACTOR ALL FURNITURE DESIGN SHOWN ON BANS IS SCHEMATIC ONLY AND NOT N CONTRACT. IMO. TENANTS FURNITURE VENDOR SHALL FIELD VERIFY PREMISE FOR LAYOUT CONRGURATION AID CLEARANCES ALL VOICE/DATA AND CABI.NG DESIGN SHOWN ON PLANS IS SCHEMATIC OM.YAND NOT IN CONTRACT, UND. TENANTS CABLING VENDOR SHALL VERIFY TENANTS REQUIREMENTS MD FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ROUGH-14 AS NOTED. COORDINATION AND SCIiEDIRNG FOR THIS PORTION OF THE WORK. THE FOLLOWING ORAWWGS ARE BASED ON ELECTRONIC OEORVATION OOi1VED FROM A NUMBER OF SOURCES. WHILE DEEMED RELIABLE, MS&A CMONOT BE HELD RESPONSIBLE FOR INFORMATION FROM OTHERS NOT FIELD VERIFIED OR WINCH HAS BEEN ALTETEO BY OTHERS CONTRACTOR TO UPGRADE SIESM!C BRACING AS REQUIRED AT SOST1 NG CEILNG. CONTRACTOR TO FIELD VERIFY ALL ELEMENTS INDICATED AS EXISTING ON RAMS. NO FIELD VERIFICATION HAS BEEN PERFORMED BY MS&A STAFF. DOORS & HARDWARE SHALL BE REUSED. RELOCATED OR NEW BASED ON AVAILABLITY AND SUITABUTY. ALL HARDWARE SHALL BE TENANT STANDARD FINISH. MATCH EXISTING CONDITIONS. COSTING as 14RL CO 1RDOR PARTITION TO REMAIN. ---- NEW WS COMIC01 PARMION TO MATO.I EOS'NG. wi CONSTRUCTION LEGEND SITE PLAN SCOPE OF WORK PARTIAL FLOOR TENANT IMPROVEMENT ON THE FIRST FLOOR OF AN EXISTING OFFICE SPACE WHICH IS APPROXIMATELY 3.816 U.S.F. THE WORK CONSISTS OF DEMOLITION AND CONSTRUCTION OF PARTITIONS, DOORS, OTHER FEATURES. THERE IS NO STRUCTURAL OR CORE AND SHELL CONSTRUCTION TYPE: TYPE V-B SPRINKLERS: SPRINKLERED LEGAL DESCRIPTION : ALL THAT CERTAIN REAL PROPERTY SITUATED IN THE CITY OF TUKWLA, COUNTY OF KING STATE OF WASHINGTON. BEING A PORTION OF THE EAST 112 OF THE NORTHWEST 114 OF THE SOUTHEAST 114 OF SEC. 26, T.23N. RAE. W.M., AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINING AT THE INTERSECTION OF THE NORTHERLY UNE OF SAID SOUTHEAST 114 WITH THE WESTERLY MARGIN OF ANDOVER PARK WEST (59TH AVENUE SOUTH), DISTANT ALONG SAID NORTHERLY LINE N88'0542'W 1334 FEET FROM THE NORTHWEST CORNER OF SAID SOUTH- EAST QUARTER THENCE FROM SAID POINT OF BEGINNING A.OND SAID WESTERLY MARGIN SO1'4T19'W 451.30 FEET; THENCE LEAVING SAID WESTERLY MARGIN TANGENT TO THE PRECEDING COURSE ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 90'490, AN ARC LENGTH OF 78.64 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 501.40 SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 114; THENCE ALONG SAID PARALLEL LINE N88'0542'W 180.90 FEET TO A PONT ON A UNE THAT IS PARALLEL WITH AND 261.00 FEET WESTERLY OF THE EAST LINE F SAID EAST 1/Z THENCE ALONG LAST SAID PARALLEL LINE NO1'47 E 136.00 FEET TO A POINT ON A UNE THAT IS PARALLEL TO AND 365.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 114; THENCE ALONG LAST SAID PARALLEL LINE S88•OS42'E 37.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 223 -50 FEAT WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01•4T27'E 1 10.00 FEET TO A POINT ON A UNE THAT IS PARALUM TO AND 265.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 114; THENCE ALONG LAST SAID PARALLEL UNE N88'05'4211112.50 FEET TO A POINT ON A LANE THAT IS PARALLEL TO AND 236.00 FEET WESTERLY OF THE EAST LINE OF SAID EAST 112; THENCE ALONG LAST SAID PARALLEL UNE N01•4T71E 265.40 FEET TO A POINT ON THE NORTHERLY LINE OF SAID SOUTHEAST 114; THENCE ALONG SAD NORTHERLY LINE S881)&42'E 206.00 FEET TO THE POINT OF BEGINNING AND CONTAINING 2.408 ACRES OF LAND MORE OR LESS_ INTERNATIONAL BUILDING CODE, 2006 EDITION. AS ADOPTED BY THE STATE OF WASHINGTON. INTERNATIONAL FIRE CODE, 2006 EDITION. AS ADOPTED BY THE STATE OF WASHINGTON_ ICC A117.1, 2003 EDITION. WASHINGTON STATE ENERGY CODE (WSEC), WAC 5141 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (WSVIAQ) PROJECT DIRECTORY : BUILDING REPRESENTATIVE MERIWETIIER PARTNERS LLC 2ND & SENECA BUILDING 1191 2ND AVE SUITE 1590 SEATTLE, WA (206)816- 1570(P) (206) 3811200 (FAX) CONTACT: ASIANNAN JOEL P. EMAIL_ jasiarran®mwicao.nan SPAS PLANNER MARVIN STEIN AND ASSOCIATES, LLC 2221 5TH AVE SEATRE, WASIONGTON 98121 CONTACT: USA BOLSTER TEL (206)441 -1449 FAX (206)441 -4361 EMAIL: Lbolster@marvireteitcom MINKLER BLVD. SEPARATE PERMIT REQUIRED FOR: 11-5 ELECJ COMMUNICATIONS PLAN BLDG 2 City of Tukwila BUILDING DIVISION CHECKED BY: SN REVISIONSASSUANCE: NO. REVISIONS INDICATED THUS A REVISION — CONSTRUCTION SET BUILDING DEPARTMENT REVISION CUSTOMER RESEARCH PERMIT SET DATE: 07/24/07 SCALE: AS NOTED 08/03/07 08/17/07 FIRST FLOOR COVER SHEET & DETAILS RECn`:ED I ACT ADJ AFF ALT ALUM APPROX BLDG BLKG BIS CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT OA DIM DR DW DWG E EA El EC ELECI ELEV EXIST EXT FIN FLR FLUOR FR FT FURN GA GALV GD GL GW8 HC HOW HM HT HVAC IN INCL NSUL INT JT ACOUSTICAL CEILING TILE ADJACENTIADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC OR CONCRETE TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING, EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISHFURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS'GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING. AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT ABBREVIATIONS LL@TE BY LANDLORD AT TENANTS EXPENSE IF LINEAL FOOT MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MID MOUNTED MIL METAL MW MICROWAVE OVEN N NORTH, NEW WA NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OPNG OPENING OPP OPPOSITE ORIG ORIGINAL PERM PERMANENT PL PLATE P LAM PLASTIC LAMINATE PLYWD PLYWOOD PR PAIR PTR PARTITION R RADIUS, REMOVE, RELOCATE RB RUBBER BASE REF REFRIGERATOR REINF REINFORCING REED REQUIRED REV REVISION REVERSE RM ROOM RO ROUGH OPENING S SOUTH SCHED SCHEDULE SC SOLID CORE SECT SECTION SIM SIMILAR SPEC SPECIFICATION SQ SQUARE STD STANDARD STL STEEL STOR STORAGE SUSP SUSPENDED TEL TELEPHONE TYP TYPICAL LINO UNLES NOTED OTHERWISE VCT VINYL COMPOSITION TILE VERT VERTICAL 1Y WEST WI WITH WO WITHOUT WC WALLCOVERING WD WOOD WSBF WASHINGTON STATE BARRIER FREE VERTICAL WIRE HANGER -NO.12 GAUGE 4t0' O.C. OR NO. TO GAUGE @ 5-0' O.C. ALONG EACH MAIN RUNNER HEAVY GAUGE WIRE'PIM. VERTICAL STRUT @ 17-00 EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE. HELD IN PLACE BY VERTICAL WIRE HANGER AN0 HEAVY GAUGE WIRE PIN. HEAVY DUTY MAN RUNNER AT 4'-0' O.C. VERTICAL STRUT FASTENED TO MAW RUNNER CROSS RUNtaR INSTALLATION INSTALL PER NTEIDlATIONAL BUILDING CODE SECTION 6033 9.1.1. AND 1621.1 BEADED ACOUSTICAL CEILINGS' AID ASCE 7 SUSPENDED CEILING SUPPORT DATA LATERAL SUPPORT SNAIL BE PROVIDED BY FOUR IRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART MD CONNECTED TO THE WIN RUNNER WTHN 2' OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT MN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL LE PLACED 17-0'0.C_ IN EACH DIRECTION. WITH THE FIRST POINT WITHIN 4=0' FROM EACH WALL. PROVIDE LATERAL BRACING AT AU. GELLING AREAS GREATER THEN 144 SF SURROUNDED BY WAILS THAT CONNECT DIRECTLY TO STRUCTURE ABOVE. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS. PER 2003 DC SECTION 803.9.1.1. CROSS RUFAERS ATTACHED TO MAIN RIJPQERS SY SADDLE TYING WITH ONE STRAND NO. 16 U.S. GAUGE TE WV . OR APPROVED EQUIVALENT, PER 2004 SC SECT /ON 8039.1.1. OISCONTNJOUS ENDS OF CROSS -ILIA ERS MD MAN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN S OF SUCH DISCO k'11NUTES AS MAY OCCUR 'MERE CEILING IS INTERRUPTED BY A WALL. CEILINGS OVER 2500 SF *1ST HAVE SEISM SEPARATION JOINTS OR FILL HT PINS THAT BREAKS TIE CEILING UP INTO AREAS NOT EXCEEDING 2500 SF. FOR CEILINGS WO RIGID BRACING. SPRINKLER HEADS AND OTHER PENETRATIONS SWILL HAVE A 2 N. OVERSIZE RANG. SLEEVE. OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR ME MOVEMENT OF AT LEAST I N IN ALL HORIZONTAL DEIRECTIONS; OR. SPRINKLER lEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMODATE 1 IN OF MNG MOVEMENT N ALL HORIZONTAL DORECTIO 1.5_ CHANGES N CEILING RAN ELEVATION SHALL BE PT RED WITH POSITIVE BRAICiNG. CABLE TRAYS AND ELECTRICAL. COEDITS SHALL BE SUPPORTED NDEPEIADENf TLY OF THE CEILING. CONTRACTOR SHALL VERFY LITERAL BRACING AT COSTING CI3LNG GRID & UPGRADE TO DETAILS SHOW NOTES - 1. CONTRACTOR SHALL VERIFY LITERAL BRACING AT E0.STNNG CLUNG GRID& MGM* TO CULT COPES AS NECESSARY. 2 POKER DRIVEN FSTEAERS SWILL NOT BE USED FOR TLRr'StON LOWS AAPPUCATIOENS- 3 THE GRID SHALL BE ATTACHED AT TWO AOJACEh? *ALS 8 1 SUSPENDED CEILING SUPPORT DATA • PROVIDE A LAYER OF 4.0' WIDE ACOUSTICAL CEILING TILES INSTALLED HORIZONTALLY ON EITHER SIDE OF PARTITION. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. 118' BLACK FOAM TAPE ' lOLO BACK 114' FROM EDGE OF TRACK T1W111f 4 61111 . t%vv C - J I PROVIDE ACOUSTIC BATT INSULATION MER BETWEEN STUDS AT SOUND AND DEMISING PARTITIONS. (2) #10 SCREWS REVEAL (PAINT BLACK) OR MATCH EXISTING. 1A8' BLACK FOAM TAPE HOLD BACK 114' FROM EDGE OF TRACK: ZIMCIMCL '1411 IN BIS TENANT INTERIOR PARTITION. BAS TENANT DEMISING PARTITION. NA 4 B/S STANDARD PARTITION cccccccccccccU .W ((l,W tcccccccccccccc LATERAL BRAaNG TENANT Wafts (NO CASEWORK) WNW COW NNW SUN NNW sift( �- /NW 1 t t` t II I HEAD SECTION PLAN VIEW BASE. AS SCHEDULED. BASE SECTION NA 9 I PARTITION HEAD BRACING DETAIL SEISMIC BRACING PER 4111.1. 114' NON-COMS. WD FILLER UNDER MAIN RUNNERS CONTINUOUS CEILING GRID DO NOT CUT. LINE OF CEILING GRID BEYOND, SEE RCP. CONT. t' METAL TRIM WI PAPER WING CONT. 3 112' x 1 i/4' 25 GA TRACK WI (2) 110 SCREWS ft24'O.C. 3 1n" x 25 GA. GALV. STEEL STUD Q 24' O.C. WITH 518' TYPE % GWB EACH SIDE. 518' GWB. TYPE T EACH SIDE. TYP_ CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REc D. HRTI POWER DRIVEN FASTENER 314' MN. EMBEDMENT. METAL STUDS STAGGERED ft 8%0' 0.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 17-0 ATTACH TO STRUCTURE ABOVE WI HMI POWER DRIVEN FASTENER 314' MIN. CONTINUOUS CEILING GRID - DO NOT CUT. SUSPENDED CEILING. 3112'X25 GA. SR. STUDS 24' O.C. vas/TOWS. TYPE IC. EACH SIDE_ LATERAL BRACING PER DETAIL ABOVE (WP.) NOTES: 1_ LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. QC_ LICIT AT INTERSECTIONS YITTH WALLS ATLEAST4 FT. LONG. (PER f PART. RAN) a TEfII ORARY ATTAC1iLIERT OF PARTITION TOP TRACK TO TIE CRS IS PERMITTED TO ALIGN AND SET THE WAAI.L LAIN. PERK ROM BRACING IS PROVDED. REMOVAL. OF TIE TM:ORARY HOLDING SCREWS IS UPTOTIE DISCRETION OF THE SPECFIC LOCAL. BUILDNGOFFICIAL. CONTRACTOR TO VERIFY. 3. FRO/DE BRAKING AT MY PERTLY PARTITION THAT IS NOT ATTACHED TO CEILING G. • NTS NTS 11 I LIST OF DRAWINGS NA • SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 REGISTERED ARCHITECT OFM Marvin St sociates, LLC planning v design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAY 1 BY: LW REPRODUCTION. ALTERATION OR PUBUCAUON OF 11115 DIMING. * OUT EXPRESS PERMISSION BY US&A. IS A VA[aA11Q4 of FERAL CCPYRICNT LAN. OBIT BY VS1&A 2 JOB NO.: 99135.004 Of FIRST FLOOR PLAN 118' =1'.0" 0 5' 10' • • 0 20' 0 0 NORTH r� =� it t I ti , i _____7i. II il 11 i 1 1 II I tI 1 II l � n / N k " - ''J I I I : I I V 7' ''.4 • � REMOVE AND RELOCATE TO LOCATION SHORN ON CONSTRUCTION PLAN :3 r • r -� i}1 LOBBY • GENERAL DEMOLITION NOTES: 1. SALVAGE PHONE BOARD AND EQUIPMENT FOR REUSE. ronP (-)-!;I Iv: , 1 AUG -' City Of BUILDIN '''`.:: - : SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 Marvin St TENANT: SHEET RILE: • planning 2221 Fifth Avenue, Seattle, Washington 98121 1206)441 -1449 DRAWN BY: LW JOB NO.: 99135.004 CHECKED BY: SN DATE: 07/24/07 REVISIONS/ISSUANCE: NO. REVISIONS INDICATED THUS A CUSTOMER RESEARCH FIRST FLOOR DEMOLITION PLAN Doi- Lag ALTERATION OR PUBUCAUCN OF Ills DRANK NI OJT EMIESS PE: MISSION BY NW, IS A MAIM OF FEDERAL OOPIRIQfT LAIL OOPIrRIG1T BY MS&A 2007. sociates, LLC design PERMIT SET SCALE: AS NOTED RECF1VE1.. 2 DATE TI -2 Cr 5 a i i E MULJPTN. OPEN WORK AREA 103 OPEN WORK AREA OPEN WORK AREA 105 0 a I I I I I I I - -- t ° r -- 1 - - - - I L I I II I I I I I I I --L--L— J- -- 1 a 1 102 IA1 I I I I I I — 1 --- r - - -- - -- - - I I I 1 I I I t I I I I I I I I I L I t I I t I r -- r -- _ y -- -� - -- I I I I I I I t I I I t I I I I I I I I ^ I LJ WORKSTATION LAYOUT. NOTE: TENANT RUNS (2) EMPLOYEE SHIFTS WITH A MAXIMUM OF 38 PEOPLE AT ONE TIME ON SITE. SHIFTS ARE 8:00 AM - 2:00 PM AND 230 -8:30 PM. FIRST FLOOR PLAN 10 20' NORTH I •1 OPEN WORK AREA 102 106 107 108 • s-0 IT ROOM 101 N.I.C. 1 r RECEPTION 100 BRENCROOM 109 4 I ELEC. - LOBBY N.I.C. ;Rc Kiir EL Il li ii 1 • GENERAL CONSTRUCTION NOTES: CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY DEMOUTION REQUIRED TO COMPLETE THE WORK AS OESCRIBED ON THE CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL PROTECT ALL EXISTING FINISHES AND ASSEMBLIES NOT BEING REMOVED OR ALTERED DURING CONSTRUCTION. CONTRACTOR SWILL PROVIDE NEW FRAMING AND FINISHES THAT ARE FLUSH, CONSISTENT AND N ALIGNMENT WITH COSTING CONDITIONS. IN THE EVENT OF FRAMING SIZE DIFFERENCES, THE CONTRACTOR SHALL FURR OR ADJUST THE FRAMING AS REQUIRED FOR PROPER ALIGNMENT. CONTRACTOR SHALL VERIFY MINIMUM FRAMING SIZE REQUIRED FOR ELECTRICAL, MECHANICAL AND PLUMBING FEATURES BEING INSTALLED BY OEStGNIBUILD AND ADJUST THE FRAMING ACCORDINGLY. CONTRACTOR SHALL PATCH TO MATCH AND PREPARE FOR FINISH AT ALL LOCATIONS WHERE EXISTING ASSEMBLIES ARE ADJACENT TO DEMOLISHED OR ALTERED ASSEMBLIES. THE SCOPE OF WORK SHALL INCLUDE BOTH SIDES OF ALL NEW ASSEMBLIES DEPICTED ON THE DRAWINGS EVEN WHEN LOCATED IN AN ADJACENT LEASE SPACE. NO PART OF THE WORK IS TO BE LEFT UNFINISHED U.N.O. CHANGES TO SPECIFICATIONS CAN BE MADE IF APPROVED BY MS8A, THE BUILDING MANAGEMENT AND THE TENANT. CONTRACTOR SHALL SUPPLY ALL REQUIRED JUNCTION BOXES, COVERS AND ACCESS 000RS AS NECESSARY. VERIFY BUILDING STANDARDS. CONTRACTOR SHALL CONFIRM TYPE AND LOCATION OF FIRE EXTINGUISHERS AND/OR CABINETS WITH THE GOVERNING FIRE MARSHAL BEFORE INSTALLATION. IF NOT SPECIFIED ON DRAWINGS, CONTRACTOR SHALL PROVIDE THE MINIMUM NUMBER OF WALL MOUNTED FIRE EXTINGUISHERS REQUIRED BY CODE VERIFY WITH BUILDING MANAGEMENT. CONSTRUCTION KEY NOTES: 0 RELOCATED EXISTING RE31TE 0 en 12' DEEP RAM UPPER CABS. WITH DOORS AND (2) AEU. SIiELVES. O WSA.DA- APPROVED COMPLIANT SINK A FAUCET) 0 NS 24' DEEP PLAN LOWER CABS. Wail DOORS, DRAWER. (1)ADJ. SHELF. 4 - TOE KICK, 25' DEEP RAM COUNTERTOP AT 34' A.F.F. DOOR SCHEDULE: DOOR NUMBER TYPE OF DOOR A. NEW INS 3-0r'WIDEX RILL HEIGHT 20 _ -- RATED WOOD SUITE ENTRY DOOR & 8. RELOCATED BIS 311' WIJE X RILL HEIGh T S.C. '- WOOD DOOR W BISFRAfIE. HARDWARE a. BrSLOCICSETACLOSER e. COSTING HARDWARE ® DENOTES BOWING DOOR inoU • NO. SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 Marvin Ste sociates, LLC tannin design S n � REIASIONSASSUANCE: 2221 Fifth Avenue Seattle, Washington 98121 (206) 441 - 1449 DRAWN BY: LW JOB NO.: 99135.004 CHECKED BY SN DATE 08/03/07 REVISIONS INDICATED THUS A TENANT. SHEET 1111E ALTERATION OR PUBLICATION OF THIS DRANK, WTHOUT ()PRESS BY MSM, IS A tICIATICN CF FED OOPYROIT LAt CCP' 1 Q1T BY NW 2007. +tai^ • REGISTERED i ARC4ITECT OF WASHINGTON FIRST FLOOR INITIAL ISSUE SCALE AS NOTED DATE REVISION — CONSTRUCTION SET 108/03/07 BUILDING DEPARTMENT REVISION 108/17/07 CUSTOMER RESEARCH Do'•i 285 CONSTRUCTION PLAN AND ELEVATIONS RECZ i�eo TI -3 or 5 0 LOBBY • i .. _ A IiU _ : ::: Nil :CZ :: I■ ■ AI NM III ■ ■ ■ ■ ■■■ IN ■i ■■■ ■. ..R,_,,.. isi In ■■ ■ ■1111 ■■liw NO 111111111111111E 1111■■■ 1111■■ ■■ MOM, , r~ -= Ali ■■ ■■ r ■s■■ ■•■■■■■■1111 ■■ ,._ __ ■■ ■ � [1: _ s�lif I■ r ■■ ■■ • ■ __ ■i■■■■ ■■■ _■ Ti■ \ 1111111111=11111611111 ■ ■ ■� ■ •■ ■ ■ ■� ■■■ ■ ■ ■_■ ■ ■■■ ■ ■.■■■■■ r 1 1 ._I__••.iuua•uu.iu == ■ iii ■ ■ ■■ ■■_1 ■f■■■■ 1111_ ■■■ _1111 ■ ■IIIIIM■ ■ ■■,Mr /ir■■ ■ ■■ KIM■■ 1 l■■ � ■1111,1 .. ■f� ■�■■■ ■ ■111��'.�IMS i■�i ■1111■ I'. 1 ■ ■ dirt%) ■� �■■■ ■_ 1 i : :i■ ■ ■ WIIr■■ 1 1111 1111■ imi ■ i ■i iimuii_!]Im■■NI iiva Riauaivamuauiuuiuurnu I iuiu 1111114/1111111111111IN 1 11110■ ■ ■t ■ ■r ER Wilill a ■■ ■■141 MUM 1 1111■■■ 1 ■■t■■ ■■ i 1111■■ ■ n■r■ ■■ ■n■� ■ ■�1 �■■�■■■■ � 1 1111 ■ ■ ■■i■I n■■■■■ ■ ■__��1 ■■� ■■■ ■■I ■� ■ ■ 111111111111110111111111 111111�M■ ■ ■11� _,, X11•111■ ■• ■I ■■ liii � m III Ili I ■ ■ ■■ ■. ■■i Erg :L AREA OF NEW G.W.B. CEILING TO MATCH EXISTING N CORRIDOR. • LOBBY _;ELEVATOR 'IOW* ilkit-Eit. 0 5 10• FIRST FLOOR PLAN i • 20' 30' NORTH • • t_ c • GENERAL LIGHTING NOTES: ALL ASPECTS OF THE DESIGN A CONSTRUCTION OF THE HVAC SHALL BE PERFORMED BY THE CONTRACTOR RE-CIRCUIT SWITCHING OF EXISTING LIGHTING AS NECESSARY TO COMPLY WITH NEW LIGHTING LAYOUT. CONTRACTOR SHALL VERIFY LATERAL BRACING @ OUSTING CEILING GRID & UPGRADE TO CURRENT CODES AS NECESSARY. REUSE EXIT SKINS AS POSSIBLE. THE CONTRACTOR SHALL REPAIR OR REPLACE ALL DAMAGED CEILING TILE AND GRID AS NECESSARY TO MATCH EXISTING ADJACENT UNO. PRIOR TO INSTALLWG ANY LIGHT FIXTURES ON THIS PROJECT, THE CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH SOWING MECHANICAL DUCT WORK. ELECTRICAL CONDUIT, FIRE SPRINKLERS, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS. THE CONTRACTOR IS TO NOTIFY MS&A OF THE CONFUCT(S) SO NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. THE CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING PER CODE. THE CONTRACTOR SHALL PROVIDE AUDIBLE AND VISUAL ALARMS PER CODE ALL LIGHTING AND CONTROLS SHALL BE B1S. UNO. THE CONTRACTOR SHALL SATISFY THE LIGHTING SPECIFICATIONS BASED ON THE AVAILABLE ELECTRICAL VOLTAGE. CONTRACTOR SHALL COMPLY WITH ALL AUTOMATED SHUT -OFF CONTROLS. SWITCHING, SENSORED SWITCHES, TIMED SWITCHES, AND TESTING AND COM6ISSIONNG REQUIREMENTS. 00CUMENTS SHOW SCHEMATIC SWITCH LOCATION ONLY. ALL WS EXIT LIMITS SHALL BE ' LED' STYLE AND LESS THAN 5 WATTSSFIXUJRE, UNO. LIGHTING CALCULATIONS WHIM ALTERATION (2)7 X4' LIGHT FIX1URES RELOCATED. THERE IS NO CHANGE IN WATTAGE LIGHTING LEGEND i EXISTING WS 7-0' x 4'-W RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN i w i WS 7-0r x 4'-0r RECESSED FLUORESCENT UGH!' FIXTURE TO BE RELOCATED i� RELOCATED BIS7.Or'x4'-0r RECESSED FLUORESCENT LIGHT FIXTURE J EXISTING BIS 7-0' x 7-0 RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN ® WS RR SIGN (01RECT10NAL VME iE SHOWN) (N = NEW) U). &S SWITCH (3 =I REEWAY)(D= OEMOUSH)(PI =NEVI) I R`VI! err -! -i r .'' AUG Cit Of Tvk BUILDI r EXISTING (RALY SHADED)AND RELOCATED (PARTIALLY SHADED) WS 2'41r x 1-0' RECESSED FLUORESCENT LIGHT FORUM FOR EMERGENCY UGHITNG. EMERGENCY UGHTNG LAYOUT SHOWN IS CONCEPTUAL ONLY. ELECTRICAL CONTRACTOR TO PROVIDE DESIGN NO. SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 Marvin Ste planning v design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: LW JOB NO.: 99135.004 CHECKED BY: SN DATE: 07/24/07 REVISIONS/ISSUANCE: REVISIONS INDICATED THUS A REGISTERED ARCHITECT . OOH NAHOU OFVOGIIIlNGIVIN BUILDING DEPARTMENT REVISION TENANT SHEET TITLE REFROOLIC ROM ALTERATION OR PUB CATION Or THIS CRAM% 1111HOUT MESS FIERKS9Cel BY YS&A, IS A 1AOLATION OF FEERM. COPYRIGHT Al. L CO 1 BY VS&A 2007. sociates, LLC PERMIT SET SCALE AS NOTED DATE CUSTOMER RESEARCH I bo3 28g 08/17/07 FIRST FLOOR REFLECTED CEILING PLAN RECEIVED 4� _ f' E::7: 1 1I (.bti TI-4 OF 5 I • )- - Co j,4 a a ' 4 j,6 6 7 ow an 6 6 7 UU IFPBFP 11'8' =1'-Or U • uU FIRST FLOOR PLAN Lj Uu :8FP8FP 30' u aw NORTH C U OFP[ ELEC. /COMMUNICATIONS LEGEND 8iS WALL tome) DUPLE( EMLECTRICAL OUTLET • %- NEW BSWALL MOUNTED OUTLET I; I GRADE E GSTRG TO AS swim BS BUlrt( FACE RATE utlFPI; BS WALL MOUNTED DEOIC.ATE D 1201 aok DUPLEX ELECTWCN.OUTLET E`» 8S WALL MOUNTED BOX I.!) 8S WALL 110UNIED COIBNATEON VOICEAATA OUTLET b SS WALL MOUNTED DEDICATED VOICE OUTLET 1 # .---" W ti. MOUNTED VOIC A)ATA CONNECTION TO TENANTS S FU RNITUZE PAS SYSTFIIL ( (#) VOICE AEI ,J # {S) DATA LINES PER Y STATION). ( 18AEER =OI,wart OFWORKSTATIONSSERVED). . WALL MOUNTED JUNCTION BOX TO BE CONIECTED TO ANTS FURNITURE P»6. SYSTEM -POWER FOR ft) DUFLEX ELEC. OUTLETMORIQTATION. AMBER =OUANTITYOFWORISTATIONS �L:1L t 4 ELEC. /COMMUNICATIONS PLAN NORTH 0 5' 10 20' 3O' GENERAL ELEC./ COMMUNICATION NOTES: I. REUSE OPENING AT BEAN( FACE PLACES (BFP) AS POSSIBLE. 2. CONTRACTOR TO RELOCATE ALL EXISTING ELEC. PANELS TO NEW IT ROOM. 3. AT OUTLET LOCATIONS TO BE REMOVED. PULL OR CAP WIRES ASREQUIMED BYCOOE 4. AT OUTLET LOCATIONS TO BE UPGRADED TO BLANC FACE PLATE (MP), PULL OR CAP 1MRESAS REQUIRED BY CODE. ELEC./COMMUNICATIONS KEY NOTES: O DOSING FACE PLATES A.NUPICRON BOXES TO BE REMOVED (TYPICAL). WALL FILLED A PATCHED TO WATCH E OST1NG WALL CONOMTIONS SOUTHCENTER CORPORATE SQUARE BUILDING 2 TENANT: • 565 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 8862 REGISTERED tt ARCHITECT 'P 1111 G: OF Wi SN}i1NGTON Marvin Stetisociates, LLC tannin design S n S 2221 Fifth Avenue Seattle; Washington 98121 (206) 441 -1449 DRAWN BY: LW CHECKED BY: SN REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS P 94=E TIRE: FIRST FLOOR A fir'- DTF tSS FEFV'JS II Ey tAA. Ij i :c1 :N Cf FE t`'. C�► .+:' LAX. CCP'T =: 1H_ { �QA ;'-:j?. JOB NO.: 99135.004 INITIAL ISSUE DATE: 08/03/07 SCALE AS NOTED DATE CUSTOMER RESEARCH U07- 28g ELEC. /COMMUNICATIONS PLAN RECEPEf N: 2 f �.. TI -5 :F 5