Loading...
HomeMy WebLinkAboutPermit D07-286 - FAMILY FUN CENTER - OFFICEFAMILY FUN CENTER WORLD HEADQUARTERS 7100 FUN CENTER WY D07 -286 Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: City-if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: FAMILY FUN CENTER WORLD HEADQUARTERS Address: 7100 FUN CENTER WY, SUITE 100 , TUKWILA WA Owner: Name: H2 OFFICE LLC Address: 7300 FUN CENTER WAY , TUKWILA WA 98188 Phone: Contact Person: Name: SCOTT HUISH Address: 7100 FUN CENTER WY , TUKWILA WA 98188 Phone: 503 - 381 -9590 doc: IBC -10/06 DEVELOPMENT PERMIT Contractor: Name: AXIOM COMMERCIAL CORP Address: 13110 NE 177TH PL #312 , WOODINVILLE WA 98072 Phone: 425 - 486 -8720 Contractor License No: AXIOMCC997NH * *continued on next page ** Permit Number: D07 - 286 Issue Date: 10/17/2007 Permit Expires On: 04/14/2008 Expiration Date: 11/06/2007 DESCRIPTION OF WORK: TENANT IMPROVEMENT FOR 1,221 SQUARE FOOT OFFICE INCLUDING INTERIOR PARTITIONS AND FINISHES. PLUMBING, ELECTRICAL, WIRING AND LIGHTING UNDER SEPARATE PERMITS. Value of Construction: $36,630.00 Fees Collected: $1,052.61 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 D07 -286 Printed: 10 -17 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: Signature: Print Name: City chriTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N Private: Profit: N Private: Permit Number: D07 -286 Issue Date: 10/17/2007 Permit Expires On: 04/14/2008 Public: Non - Profit: N Public: Date: Io -1' I hereby certify that I have read and x ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the of work. I am authorized to sign and obtain this development permit. Date: 140 `/7 ^07 This permit shall become null and void if the work is not cort{menced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D07 -286 Printed: 10 -17 -2007 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 2423049092 Permit Number: D07 -286 Address: 7100 FUN CENTER WY TUKW Status: ISSUED Suite No: Applied Date: 07/31/2007 Tenant: FAMILY FUN CENTER WORLD HEADQUARTERS Issue Date: 10/17/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until fmal inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the D07 -286 Printed: 10 -17 -2007 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us following concerns: 15: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IF'C 906.7 and IFC 906.9) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Maintain fire extinguisher coverage throughout. 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: In Group B and M occupancies, the minimum clear aisle width shall be determined by the occupant load served, but shall not be less than 36 inches. (IFC 1013.4.1) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) D07 -286 Printed: 10 -17 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 30: Each circuit breaker shall be legibly marked to indicate its purpose. (NEC 110 -22) 31: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 32: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 33: All interior demo debris must be removed prior to demo of the automatic sprinkler system. Contact the Tukwila Fire Prevention Bureau at 206/575 -4407 for an inspection of the building prior to shut down of the automatic sprinkler system. 34: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 35: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 -575 -4407 for ordering information. 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 514. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D07 -286 Printed: 10 -17 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 44 /18")0/(Le doc: Cond -10/06 D07 -286 Date: /la ---17 -4 7 ordinances governing or local laws regulating Printed: 10 -17 -2007 Contact Person: E -Mail Address: CITY OF TUKWIL4 Community Developmenrbepartment Public Works Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA" 98188 http://wwwatukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 71 00 coo CE4tThg. tNi`(' Tenant Name: Property Owners Name: I-14411,1 %J c4.4.tert. Mailing Address: 73017 'AMC*411 - V17— W�r� Q'. gl 14 Name: ' O 'HU 1-.14 Mailing Address: 0 ' , I � � U / _ - E/� E -Mail Address: Flo lit,/ (494 Q:\Appliationa\Ponms- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh King Co Assessor's Tax No.: Z4 20 Suite Number: - tuk4)(1.-et City 4lew Tenant: ER.... Yes ❑ ..No 'NA tate Floor: 1 Zip o we contact when your permit is ready to be issue Day Telephone: 50 331 qop W [.� 4 4 - . lab City State Zip ``-- Fax Number: 006- 7 3 � S3 6 c v GENERAL CONTRACTOR INFORMATION (Contractor Information'forMechanical (pg 4) for Plumbing and Gas Piping Company Name: MID /4 C O/JSTR ON Mailing Address: 3 10 NE /77" �� A' � /�- �l�V!'vl.� (007� 11 ' L City State Zip Contact Person: Ni C/` 641,1 S17 Day Telephone4;f9 J • ,_ c a 77 5 E -Mail Address: Fax Number: L , ESC/ . &ed. 0 Contractor Registration Number: 4 QAl CZjgg7AJf 7' Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Recor Company Name: M OliVk / Mailing Address: State City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip Contact Person: E -Mail Address: Page 1 of 6 BUILDING YERMIT'1NEQRMATIQN 2Q6= 43 1367 Valuation of Project (contractor's bid price): $ 'jj(� is 2il%Q9 Existing Building Valuation: $ Scope of Work (please provide detailed information): I' .LMk( LtA'l,ptlel. 4ITe2 ,c I , i44 4f' 1 ' LJt�IN�cy, A4'n to 6rp -cwk. Will there be new rack storage? ❑.... Yes rovide A i Building Areas -in Squtare Footage,Belo tYpl -� 13- off PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh o If yes, a separate permit and plan submittal will be required. Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: i g Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ,zj No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NO L $ - Applicable to all permits in this Date Application Accepted: 1-3t-O7 Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh i lication Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ' OR : UT IZED ENT: Signature: • U t LL� Li Date: 7 31. 07 Print Name: , J f f 14. fJ U 1,5/I Day Telephone: 42 O( • /1 36 6 Mailing Addre 7100 f ji ! ( 1 7 / WA y TL)KW I & iN" 'M k City State Zip Date Application Expires: l-3i Staff I niti& Page 6 of 6 Contact Person: E -Mail Address: Contractor Registration Number: ,Fixture ;Typ Bathtub or combination bath/shower Bidet ew Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Building sewer or trailer park sewer Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Rain wate drain (' Repair pip eq Fixture 3Type • -''. Drinking fountain or wate cooler (per head) Food -waste grinder, commercial Floor drain Shower, single _ . d trap Lavatory Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh ystem — per de building) r alteration of water and/or water treating ment PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets be g installed and the quantity below: Fixture Type :. Wash fountain Receptor, indirect waste Water Closet Water heater and/or vent Repair or alteration of drainage or vent piping City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): ure „T'yp Gas piping outlets Additional medical gas inlets/outlets — six or more Medical gas piping system serving one to five inlets/outlets for specific gas Page 5 of 6 Parcel No.: 2423049092 Permit Number: D07 -286 Address: 7100 FUN CENTER WY TUKW Status: PENDING Suite No: Applied Date: 07/31/2007 Applicant: FAMILY FUN CENTER WORLD HEADQUARTERS Issue Date: Receipt No.: R07 -02268 Payment Amount: $639.72 Initials: JEM Payment Date: 10 /17 /2007 10:32 AM User ID: 1165 Balance: $0.00 Payee: H2 OFFICE LLC TRANSACTION LIST: Type Method Description Payment Check 1189 639.72 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Amount Account Code Current Pmts 000/322.100 635.22 000/386.904 4.50 Total: $639.72 404? 10/13 n(10 TOTAL dnr. RarAint -08 Printed. 1l) -17 -90(17 Receipt No.: R07 -01550 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Payee: HUISH FAMILY FUN CENTERS INC Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2423049092 Permit Number: D07 -286 Address: 7100 FUN CENTER WY TUKW Status: PENDING Suite No: Applied Date: 07/31/2007 Applicant: FAMILY FUN CENTER WORLD HEADQUARTERS Issue Date: Initials: BLH Payment Date: 07/31/2007 04:17 PM User ID: ADMIN Balance: $639.72 Amount Payment Check 10020 412.89 Account Code Current Pmts 000/345.830 412.89 Total: $412.89 Payment Amount: $412.89 0943 08/02 9710 TOTAL 412.89 doc: Receiot -06 Printed: 07 -31 -2007 Pr : f4 ,l y /1/"/ (Pf l/7 T pe of Inspectipn: / f / AJ 4 Addr ss: woo ,1 /N ( c Date Called: Special Instructions: V .-- Date Wanted: l _ Z Q -4 6. ry p.m. Requester: Phon6N : 2 ..7? I INSPECTION RECORD Retain a copy with permit INSPECTION NO. P iT NO. CITY OF TUKWILA BUILDING DIVISION FL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 A p proved per applicable codes. Ei Corrections required prior to approval. COMMENTS: I lnspector; Date: $58.00 REINSPECTION PEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Type of Inspection: I s. suc e , A:� 6G. ( ; Addre y 1 i h i r 7WO ,fJA & 1e°IS ri vi /ud0 S4- / .f , ,'-1(2 b d 1 y " Date Wanted: ey , /t ell $ L).iy, t.i A-(( Mme, _4n 1 G(.1 j PC 1 M A-A i� • S e -� -/ 7 J -‘ -/ Project: AA -; FL/A (ear Type of Inspection: I s. suc e , A:� 6G. ( ; Addre y 1 i h i r 7WO ,fJA & Date We'd: Special Instructions: / I Date Wanted: r Requester: Phone No: 70(0 -335- 217v INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION PERMIT NO. Coq -2go 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 \ Approved per applicable codes. El Corrections required prior to approval. Inspe7 l�} Date: r ,, r� 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 1 Receipt No.: 'Date: Proj,ctt: 1 t Fu' (t Type of Inspection: (0 (A2— /i Address: 6 i Date Called: J Spe ial Instructions: Date Wanted: i- Z3 — ' , Sa.m Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit X67 -2Y( PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. U Corrections required prior to approval. COMMENTS: Inspe Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project �fl�/ • 1?,n! 6 Type of Inspection: rye 4 n'r n/ 6 v Address: /_ /� c ppate 7/e) C.) / 1 e"✓de) AA/eir� / Called: Special Instructions: Date Want e /.Z / Z / � � m, Requester: Phone No: <�06 — 33.5-2 77 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 COMMENTS: nspect $ .00 REINSPECTION FE REQUI - '' . Prior to inspection, fee must be aid at 6300 Southcenter Blvd.. S e 100. Call the schedule reinspection. eceipt No.: D ate: 'Date: Z roved per applicable codes. Corrections required prior to approval. Projegt: f t 7 /71 C ( ( /- A., Type of Ins ction: - 7l 4,n /ry Address: r 7 / d 0 �' i /A) &//,✓ Date Called: Special Instructions: Date7t > o % a.m. Requester: Phone No .2' - 335 7- 2 779 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 01 7-4L(ov PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. corrections required prior to approval. COMMENTS: Al ��r• /�i� 1-1 G 'l ^ %/ 7 0 $58.00 REIN CTION FEE REQUIRED. Prior o inspection, fee must be paid at 63 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: r „,,,,,, / r_-_,,, t., / 7.4_[..., 2_ Type of Inspection: Address: 71,0 Suite #: /pe) =t,� C-00-A A u} y Contact_P rson: A/i (-- C " Special Instructions: Pre -Fire: 11 Phone No.: d oe - 337 c 7-7° Needs Shift Inspection: Sprinklers: Y Fire Alarm: Y Hood & Duct: / l / Monitor: Pre -Fire: 11 Permits: /l Occupancy Type: 1 3 INSPECTION NUMBER 4 - Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT off P. oaa .667- 2F.4 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 ri Corrections required prior to approval. COMMENTS: t OK- --7 ( 4L UK Inspector: 5- r Date: /,4 / Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: Fet,..,,) I _C r , C f , (1_ Fire Alarm: Type of Inspection:, s i c moo_ Address: 7r 0 0 . . Suite #: /00 - C - 4, , C e,i w i Contact Person: N( K Special Instructions: Phone No.: a6- 3 3 -D- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT proved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 4) /ft PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 I I Corrections required prior to approval. COMMENTS: Se Inspector: 1 y Date: I /2y Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed tot. tot. to3 a tce,•, fiaove'rccrit 2otool4,14 I 4 vb. ° 39 2. 703_ i— t o4 1....)c* IZeeeeaS►set lrtuo✓egtCKi" t D bk.- 0 ( (b_ 64 0 0 c(p , o 103 w/trrd t.ow- Vol-1• taw/trio( 5' l of Y /G4Q '1 'r tik• 4 1 N H -:r.:77 ( bp.," 6 O.0 r: ;.. v .. ' f r - (0 1,- Wall hcotA e ( 1rtc: rnMr, r ,.N F I 1 b0.0 6 O• OCT 1 fl 217 ., i , of vi, t,! v 11 C r r 1 Pr Info Project Address �'�l V� '�llt iGt%!1'C 1' V pj(� Date q /if./ 'Ql 1 (00 ci/t4 CSOT - w�� For Building Department Use ME &a s9 _ - C'vl Gwll�A, wilt g4st�6 Applicant Name: ei f kuif / � �,� Applicant Address: q/O r4 way hvke to I , & Applicant Phone: m . A 6.Z,, S3 4 Project Description Plans Included requirements. • New Building • Addition • Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive Lighting Power Allowance 0 Systems Analysis X (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Location (floor /room no.) Occupancy Description Allowed Watts per ftz -. Area in if Allowed x Area 1010 OcciO S 1- 0 1m-1. 0 i yZ( ,O tkAAtW0fAat Z% pew t i4 0.0Z- 1105.0 l Co 2008 Washington State Nonresidential Energy Code Compliance Forms 2006 Washin on State Nonresidential Ener Code Corn • iance Form Interior Lighting Summary LTG -INT � Revised Ju 2007 teration Exceptions I 0 No changes are being made to the lighting (check appropriate box - sec. 1132.3) 0 Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage rom Ta 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt (Z¢3,t otal Proposed Watts may not exce Tbt �Il dl'fAldt�lfo �I t13 Total Proposed Watt l ?-¢Z. Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturers listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. boi 286 CORRECTION RECEIVED SEP .2 6 2007 PERMIT CENTER Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1-3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retain'', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gvmnasia assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet /conference/exhibition hall" 2.0 Workshops t Laboratory spaces (all spaces not classified laboratory shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 12 Libraries 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Cleary indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflecto or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic balla- 3. LED lights. 2006 Washin on State Nonresidential Ener Code Corn • iance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 -1 Unit Lightin Power Allowance s r Ta 1 5- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 2 . 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Project Info Proj Addres Date Area (ft perimeter (If) or # of items For Building Department Use ■ Name: Appl. Name Appl. Phone Project Description ■ New • Addition ■ Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Tradable Locations v v v Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft2 (or x If) ■ ■Exemption (list) Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft (or x If) ■ ■Exemption (list) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed ■ ■Exemption (list) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed ■ ■Exemption (list) Building Grounds (luminaires > 100 Watts) Controlled by motion Sensor • Efficacy > 60 lumensNV ■ ■Exemption (list) • 2006 Washin on State Nonresidential Ener Code Corn • iance Form • Exterior Lighting Summary • LTG -EXT 2008 Washington State Nonresidential Energy Code Compliance Forms Compliance Option teration Exceptions (check appropriate box - sec. 1132.3) Tradable Maximum Allowed Lighting Wattat=_e Tradable Proposed Lighting Wattage 0 Lighting Power Allowance No changes are being made to the lighting 0 Systems Analysis 0 Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Total Allowed Watt Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. sea Watts may not exceed T otal Allowed Watts for Exterior Non- Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage roposed Watts may not exceed Allowed Watts for Category Total Proposed Watt Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 1 0.15 W /ft Building Grounds Walkways less than 10 feet wide 1.0 W/linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft: Stairways 1.0 W /ft Building Entrances and Exits Main entries 30 W/linear foot of door width Other doors 20 W/linear foot of door width Canopies and Overhangs Canopies (free standing and attached and I overhangs) 1.25 W /ft Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft Street frontage for vehicle sales lots in addition to "open area" allowance 20 W/linear foot Non- Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior Building Facades 0.2 W /ft illuminated wall or surface or 5.0W/linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W /ft 2 of uncovered area (covered areas are included in the "Canopies P and Overhangs" section of "Tradable Surfaces ") lighting. The following allowances are in addition to any allowance otherwise Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") permitted in the "Tradable Surfaces" section of this table.) Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restau rants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry • 2006 Washin • on State Nonresidential Ener• Code Corn • iance Form Exterior Lighting Summary (back) LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Form TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 20061Mashington State Nonresidential Energy Code Compliance Forms 2006 Washin • on State Nonresidential Enerq Code Corn lance Form Lighting Power Allowance Adjustments LTG -LPA Revised July 2007 Project Address I 'Date Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts pert location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception*" Adjusted LPA Watts per ft •• From Table 15 -1 based on exceptions listed in footnotes Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address (Date The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component Information Requires I Location on Plans I Building Department Notes LIGHTING CONTROLS (Section 1513) 1513.1 Local control /access Schedule with type, indicate locations 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w/backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) I 1514 IMax. watts 'Indicate watts for each exit sign I I LIGHTING POWER ALLOWANCE (Section 1530 -1532) 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) I 1511 lElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) I 1540 (Transformers (Indicate size and efficiency I 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80%. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1613.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously Illuminated (e.g., 24 -hour convenience stores), or 2006 Washin ton State Nonresidential Ener. Code Com•liance Form illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1613.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1613.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry -type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). Job Name: Job Type: Comments: Quantity: 9435 9 5: ':', a by Sea t a . V'' inch Carton Dimon. on..; Diameter: 3 1/8" Height: 7/8" - Extends Max: 7/32" Wire: 36" (color /Black) 1tlbs- 1 - Wedge T -5 8/12/18w Material List: Material #1: Housing Material #2: Trim - Polycarbonate Material #3: Reflector Saftey Listing cUL Listed for Damp L �(� • I max 12/24v - Bulb Not Included - Polycarbonate - Chrome - Chrome - Anodized Aluminum - Polished Alurr - i. . (• - :; ". 9485 -05 - Ambiance Accent Disk Light Chrome Ambiance Disk Lighting System Polycarbonate Housing W/ 36 18/2 cord UPC #: 785652948558 Fixture Type: Ambiance Finish: Chrome (05) i :, , e -_ )hicit'1 * -' : ° $~L t 'IP i- `t; ., OCT 1 0 2011 Case Weight v Of Tukwila Features: PI DING DIVISION.._ •Designed to install as a pendant or Semi - Flush Fixture instruction Sheets •English(HC -207) •French(n /a) 1" Shipping Information (UPS Shipabi» 'r i: Individual Weight Length Width Height Carton Weight Length Width Height Case Weight Length Qty: 1 0.2lbs 7" 6" 1" Qty:5 1.1 lbs 6" 5.58" 6" Qty:2000 479 lbs 48" SNIP - Product Specifications Report Create PDF CORRECTION LTR#___At 'DOT 28• httrt• /Amin» cuonntttir4t.tirtes. nr.m /04QC 11G TITA41 Page 1 of 1 sea guilI RECEIVED SEP :2 6 2007 PERMIT CENTEF n /I"1 /.nn-7 A3.1.0 JUf1O' lighting Project: Fixture Type: Location: Contact /Phone: PRODUCT SPECIFICATIONS Lamp Two 13W quad compact fluorescent lamps CFQ13W /G24q -1 • 4 pin electronic. Socket Housing Die - formed galvanized steel housing. Ballast 1 20V thru 277V HPF Electronic with end-of -life lamp protection • 347V HPF Electronic available in Canada • Optional Magnetic ballast available • U.L. listed /CSA certified. Reflector .050" aluminum reflector with low iridescent clear Alzak finish • Other finishes including wheat, straw, haze and pewter available on special order basis. Trim Ring White Polycarbonate • Optional self - flanged trim with same finish as reflector. Labels U.L. listed for through branch wiring and damp locations • Union made AFL -CIO • CSA certified. Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. Product specifications subject to change without notice. INSTALLATION Mounting Bracket Rough -in section equipped with vertically adjustable mounting brackets (up to 3 ") that accept conduit or "C" channels (HB -26 or HB -50) or linear flat bars (LB -27). Junction Box Pre -wired junction box provided with (5)W' and (1)'/" knockouts, U.L. listed /CSA certified for through branch wiring, maximum 8 No. 12 AWG 90° C branch circuit conductors (4 in, 4 out) • Junction box provided with removable access plates • Knockouts equipped with pryout slots. Mounting Frame 16 - gauge galvanized steel mounting ring with factory installed reflector mounting clips • Rough -in section (junction box, mounting frame and socket assembly) fully assembled for ease of installation • Accommodates 'A" ceiling thickness maximum. PRODUCT CODES Catalog Number 016.213Q- 650C -WH REV -10/99 6" HORIZONTAL CFL DOWNLIGHT OPEN APERTURE Two 13W Quad CH6- 213Q -650C Reflector Finish Ballast Low Iridescent Clear Alzak HPF 120.277V, Elect. DIMENSIONS ENGINEERING DATA 120V -HPF Total i ret power 28W Operating AMPS .23A Power factor >.98 T.N.D. <10% Mai. stating -5 °F/ temperature -20 °C (rest Factor <1.5 Ballast Fodor 1.0 ACCESSORIES Catalog No. HB -26 NB -SO LB -27 PLX-E PLK -M To o•der, speciy comog -umber. Wattage and Lamp Two 13W Quad CFl Description Two 26" C- channel bar hangers Two 50" (-channel bar hangers Two 27" linear bar hangers 1342W mug. poet kit (8ect. i ast) 1326W smog. power kit (Mag. past) Ordering Exampe. 0162130. .650CM 6 7/8" CEILING CUTOUT 277V -HPF 347V -HPF Canada 28W 30W .10A .09A >.98 >.98 <10% <10% -5 °F/ 14 °F/ -20 °C -10 °C <1.5 <1.45 1.0 .95 OPTIONS Wd n suffix w Nu* w 1 i , ) Catalog No. Description 347 347V, HPF Electronic Mast NPFM l20,, NPF Rug( Mast, 2 pin SF Self-Flanged Relater Ju nets Footaandles Beam Edge Footcandles Beam Center Beam Diameter Distance to Combated Plane (Feet) 2.5 10.9 9.9' 6 1.4 6.1 13.2' 8 0.9 3.9 16.5' 10 0.6 2.1 19.8' 12 0.5 2.0 23.1' 14 0.4 1.5 26.3' 16 0.3 1.2 29.6' 18 n 9 1 n 49 o' In A3.1.0 PHOTOMETRIC REPORT Test Report #: F95048 Catalog No: (H6.213Q- 650C-WH Total Luminaire Efficiency: 55.8 Luminaire Spacing Criterion: 1.5 Luminaire: Recessed Clear Alzak Reflector Downlight Lamp: Two 13W Quad Tube CFI_ lamps rated © 900 lumens each /1800 total lumens CANDLEPOWER DISTRIBUTION (Candelas) Degrees Vertical 0 5 10 15 20 25 300 60° 30 40 450 45' 45 50 30° 55 15° 60 150 600 0 ' Pcc RCR Pw 0 1 2 3 4 5 6 7 8 9 10 SO 66 61 55 50 45 41 37 34 31 28 26 80 30 66 59 52 46 41 36 33 29 27 24 22 10 66 57 50 43 38 33 30 26 24 21 19 75° 90° 50 65 59 54 49 44 40 36 33 31 28 26 Pcc - Ceiling Cavity Reflectance Pw - Wall Reflectance (%) INITIAL FOOTCANDLES One Unit, Two 13 Watt, 78.9 Beam (Beam Edge defined as 50% of Maximum Nadir Candlepower) 6" HORIZONTAL CFL DOWNLIGHT OPEN APERTURE Two 13W Quad CH6 -213Q- i50C 65 10 15 80 85 90 70 30 65 58 51 45 40 36 32 29 21 24 22 10 65 56 49 43 38 33 30 26 24 21 19 Average 391 405 425 444 456 456 440 65 418 394 75 331 245 108 12 0 0 0 0 0 0 SO 62 57 52 47 43 39 36 33 30 28 25 LUMINANCE (Average cd /m ) 50 30 62 56 50 44 40 36 32 29 26 24 22 Degrees 45 55 85 10 62 55 48 42 31 33 29 26 24 21 19 50 59 55 50 46 42 38 35 32 29 21 25 Average Luminance 26,155 10,309 0 0 0 COEFFICIENTS OF UTILIZATION -% (Zonal Cavity Method) Effective Floor Cavity Reflectance 20% (pfc) 30 30 10 59 59 54 53 48 41 43 41 39 37 35 33 31 29 28 26 26 23 24 21 22 19 10.0' ZONAL LUMEN SUMMARY Zone fattens %Lamp %Fixture 0.30' 376 20.9 37.4 0.40' 638 35.4 63.5 0.60° 996 55.3 99.1 0.90° 1005 55.8 100.0 90.180' 0 0.180' 1005 55.8 100.0 AVERAGE INITIAL FOOTCANDLES Multiple Units (Square Array) Ceiling 80% Wall 50% Floor 20% Sparing RCR1 RCR4 RCRB 5.0' 44 32 22 6.0' 31 22 16 1.0' 22 17 11 8.0' 17 13 9 9.0' 14 10 7 11 SO 21 53 49 44 41 37 34 31 29 26 24 10 30 21 52 41 42 38 34 31 28 26 23 21 0 10 0 21 51 46 41 36 32 29 26 23 21 19 8 6 12.0' 8 6 4 56 50 45 40 35 31 28 25 22 20 18 J u JU1 lighting n 1300 S V'1 r' Road 'O. Box 5065, Des Plaines, ii. 60017 -5065 mane 8/7 827 9880 FAX 847.827.2925 220 Ci :ys!e Dr., B arnalon, On'ario, Canada, 6S 636 'none 905.792.7335 FAX 905.792 0064 `!iii: us al www unoliah:in� corn I _ ,� Printed in US A ©1999 Juno Lighting, Inc Suited to standard— T grid ceilings Swing down optical system for easy relamping and maintenance Microperforated mesh lamp shields Page 1 oft Features • Efficiency o y 56.9 /a. • Swing down microperforated lamp shield for easy relamping and maintenance. • Alter soft white film image providing on inside of mesh conceals lamp direct light. g balance between reflected and • Fully recessed luminaire and lam • 95% Reflective Alter soft p co mpartment. pariment. Specular i nterior reflector paint f inish. • • Easy p body for easy installation. • Fits standard to ballast t Grid ceilings through lamp compartment. • Optional acrylic drop -down visual element. Mounting Methods/ Features Ceiling compatibility 1 / r iflP i Suited to standard exposed Slot T -grid ceilings Also available with solid opaque swing_ down lamp shield - -� ^ ^R I IGHTS QVS2GPFOE ALTER SOFT LIGHTS FOS Z' X 4' RECESSED DIRECT/INDIRECT FLUORESC 5 1/2" DEEP MICROPERFORgTED ENT 2 LAp MESH LAMP S Dimensions 23- 13/16" (605m Access Plate (2) 7 /8" KO. 'S BALLAST 47- 13/16" (1214m ( 23- 13/16" (605mm) 2 3 -7/8" (606mm) Lightolier a Genlyte Thomas Company Technical I nformation: Airport (978) 657 -7600 • We reserve or he hall R iver , MA 0 2720 • (5 (97816 - 0595 9 to rho 08167q -uio, - www. lightolier.co m _ , CnIT 2 L tolier.con LIME 674 -4710 ® alio 130 -11 r' September 7, 2007 Scott Huish 7100 Fun Center Wy Tukwila WA 98188 Dear Mr. Huish, If you have any questions, please contact me at (206) 431 -3760. encl File No. D07 -286 giA9Jotu P:\Permit Center\Cor ection Letters \2007007 -286 Correction Ltr #2.DOC jem City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #2 Development Permit Application Number D07 -286 Family Fun Center World Headquarters — 7100 Fun Center Wy This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throuzh the mail or by a messenzer service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: September 6, 2007 Project Name: Family Fun Center World HDQRS Permit #: D07 -286 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The 2003 International Building Code and 2003 WA State Energy code are specified on the cover sheet The City of Tukwila has adopted the 2006 building and Washington State Energy codes as of July 1 2007. Review construction plans and documents for compliance with 2006 building and energy codes which shall include Washington State code amendments. Make changes to the code specifications shown on the cover page induding any other code specifications within the plan set 2. Provide a reflective ceiling plan to identify lighting and type of ceiling. Suspended ceilings shall meet current ASCE code requirements. 3. Identify adjacent space or potential tenant spaces. The intent is to determine R value requirements for the demising walls, depending on adjacent heated or non heated spaces. 4. In addition to item 2) & 3) provide a detail to show roof or ceiling R values meets energy code requirements. 5. Commercial tenant improvements or new commercial construction shall be designed by a registered design professional. Please provide plans that are wet stamped and signed by a registered architect:. (IBC 106.1) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. August 16, 2007 Scott Huish 7100 Fun Center Wy Tukwila WA 98188 RE: CORRECTION LETTER #1 Development Permit Application Number D07 -286 Family Fun Center World Headquarters — 7100 Fun Center Wy Dear Mr. Huish, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3760. encl File No. D07 -286 City of Tukwila Department of Community Development Steve Lancaster, Director P:\Pemdt CenterCorrection Letters N2007007-286 Correction Ltr #1.DOC jem Steven M Mullet, Mayor R ?n/) Cnrrthrontor Rnrrlotiarrl .Crate Itl nn • Tukwila. Wa.chinvtnn 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 Building Division Review Memo Date: August 8, 2007 Project Name: Family Fun Center World HDQRS Permit #: D07 -286 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Identify type and location of heating and air - conditioning for the new space. New HVAC systems shall require a mechanical permit. 2. The plans do not show the existing buildings envelope insulation or reference current energy codes. Provide energy code information with details to identify building envelope insulation and specify wall and ceiling insulation per Washington State energy code requirements for this TI (Tenant Improvement). (2004 WSEC) 3. A plumbing permit shall be required for this TI. Should there be questions concerning the above requirements, contact the Building Division at 206431- 3670. No further comments at this time. October 17, 2007 Tukwila Building Division/Permit Center 6300 Southcenter Bl, Suite 100 Tukwila, WA 98188 Tenant improvement permit for Family Fun Center World Headquarters Tukwila Permit No. D07 -286 is issued subject to the following condition: Final inspection approval of this permit and approval of occupancy for the herein named tenant space will not be issued until the "shell" Building Permit No. D06 -218 has received final inspection approval from the Building Divi This condition is hereby acknowledged by: ' Acknowledgement to be signed by the responsible officer of the tenant 44.46 .Yd4t, Q• � Print Name: '' 4cA- 1,�4te b / . Title': t L /J,t,c� Tenant Name: DO 2- 2 '6 Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 / '- Sink, Clinic flushing 8 8 Sink, kitchen 3 2 / ` 3 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 / rn Water closet, tank or valve, >1.6 GPF 8 4 Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type IMO W i■TR WA's Property Street Address ?U�c "w tLA- WA City State ZIP Aork li-Y Ffiu e N R.. Owner's Name Subdivision Name Lot # Party to be Billed (if different from owner) Subdiv. # Block # Building Name FAM(C ft/4 CViZrag— a1 PVIWItu4r (if applicable) ( ) Owner's Phone Number (with Area Code) A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fixture Units / f Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units = • -c RCE 20 Property Tax ID # 24 0¢41 o o 1 Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B RCE King County Department of Natural Resources and Parks For King County Use Only Account # Monthly Rate 6 Month Rate City or Sewer District Date of Connection P roperty Contact Phone Number (with Area Code) Side Sewer Permit # Owner's Mailing Address Demolition of pre- existing building? O Yes ❑ No Type of building demolished Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: RCE Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi- annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. / Signature of Owner /Representative ( Date 7/ / /p 7 Print Name of Owner /Representative �JO f-I �Vi • "�V�s� -� // 1058 (Rev. 11/05) to - King County Yellow - Local Sewer Agency Pink - Sewer Customer z ACTIVITY NUMBER: D07 -286 DATE: 09 -26 -07 PROJECT NAME: FAMILY FUN CENTER WORLD HDQTRS SITE ADDRESS: 7100 FUN CENTER WAY _ Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # After Permit Issued DEP'ARTMENT& �� 6 g Mon Public Works ❑ Complete DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 `PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural Review Required ❑ Permit Coordinator Fire Prevention ❑ Planning Division Structural Incomplete DUE DATE: 09 -27 -07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10 -25 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -286 DATE: 08 -28 -07 PROJECT NAME: FAMILY FUN CENTER WORLD HDQRS SITE ADDRESS: 7100 FUN CENTER WAY _ Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: t b ��7 Buil•''g Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -30 -07 Complete Please Route Documents/routing stip.doc 2 -28 -02 Fire Prevention Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: Structural Review Required ❑ Planning Division ❑ No further Review Required REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: irfi �fVT Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Not Applicable x DUE DATE: 09 -27 -07 Not Approved (attach comments) ACTIVITY NUMBER: D07 -286 DATE: 08 -1 -07 PROJECT NAME: FAMILY FUN CENTER WORLD HDQRS SITE ADDRESS: 7100 FAMILY FUN CENTER WAY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued EPARTME TS: (1 Building Division Public Works Structural DVW1 4 4- 14 ?;-01 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 sio kg/ olir Fire Prevention Incomplete Structural Review Required Ping ❑ Permit Center Use Only CORRECTION LETTER MAILED: Crt y( IA- Departments issued corrections: Bldg Fire ❑ REVIEWER'S INITIALS: REVIEWER'S INITIALS: PW ❑ Staff Initials: tvvp Planning Division X ; Permit Coordinator DUE DATE: 08 -2 -07 Not Applicable ❑ No further Review Required DATE: DUE DATE: 08 -30 -07 Approved ❑ Approved with Conditions ❑ Not Ap proved (attach comments) Notation: DATE: Date: City of Tukwila \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Steven M. Mullet, Mayor REVISION_ SUBMITTAL Plan Check/Permit Number: D07-286 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 2. ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steve Lancaster, Director Project Name: Family Fun Center World Headquarters Project Address: 7100 Fun Center Wy Contact Person: ..of /k/S A Phone Number: .sO3 / fJ1O Summary of Revision: a/A eI / .266.4 7116 / . I� �E C'e, /• y7/ UQ /u e i At w a /15 4' ee(x Aqs / wef s�,¢rho Aiac/j. fee/ RECEIVED tA SCP 2 G 2OO7 CENTFP Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: X Entered in Permits Plus on t - )-6 - 0 1 Created: 8 -13 -2004 Revised: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ❑ Response to Incomplete Letter # Response to Correction Letter # I ❑ Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Sheet Number(s): l _ 02 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on - U', \applications\fonns- applications on Iinelrevision submittal Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: R1.28/, 7 Plan Check/Permit Number: DO 7cV Project Name: L T A 1 V DRL j) h pn 0j9- 7E�/QS Project Address: 7/6 C,r! m7 tV,4 y sU17E 1 '8 TUKW1 j NI It 'We Contact Person: S(777 (0.521- Phone Number: 643 - - ` $ /- 9' f D Summary of Revision: /\/12T -6 ( PLAINS Ft94 ,° M / ,V 4 4-/14 R 6V r,, P(,(AMC.4e cow S MEcblV U CITY OF TUKWILA AUG 2R1001i Pc FIMF. - . License Information License AXIOMCC997NH Licensee Name AXIOM COMMERCIAL CORP Licensee Type CONSTRUCTION CONTRACTOR UBI 602131679 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 13110 NE 177TH PL #312 Address 2 City WOODINVILLE County KING State WA Zip 98072 Phone 3606681029 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/16/2001 Expiration Date 11/6/2009 Suspend Date Separation Date Parent Company Previous License AXIONCS995KJ Next License Associated License Business Owner Information Name Role Effective Date Expiration Date GALASH, NICK B PRESIDENT 05/31/2005 Bond Amount GALASH, STEPHEN J PRESIDENT 08/08/2001 05/31/2005 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 CONTRACTORS BONDING AND INSURA SG7570 07/17/2006 Until Cancelled $12,000.00 06/08/2006 Look Up a Contractor, Electririan or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AXIOMCC997NH 10/17/2007 REVISION LIST NUMBER DATE SHEET NOTE \ 9/1 2/2007 A I .0. 2.0 PER PERMIT REVISION RECEIVED SFP,267nn7 PERMIT =NITER L 5'-4 2-0" a • . 16' -0" 24'2' N NOT TO SCALE AZ \i J BUILI1\C FLOOR PLA, 25' -0° 6- 10 112" 3'-0" 25' -0" 10 A -3.0 RCP / LIGHTING PLAN RCP LEGEND RCP GENERAL NOTES CEILING DETAILS 24' -2° A - 1.0 BUILDING FLOOR PLAN VICINITY MAP PROJECT DATA GENERAL CONSTRUCTION NOTES CONTACT INFO SHEET INDEX A -2.0 FLOOR PLAN WALL LEGEND DOOR / HARDWARE SCHEDULE DOOR & DOOR FRAME TYPES TYPICAL INTERIOR WALL SECTIONS BUILDING FLOOR PLAN �J Co REVISIONS No changes shall be made to t scope of work without prior approval Tukwila Building Division. NOTE: Revisions will require a new plan submittal ' may include additional plan review fees DRAWING INDEX: PILE CO Permit No. Nan review approval Is subject Appluel of construction eccum, the violation of any ac c;:::J co( el approved Mel G --- Date \\* 7 -`� Oty of INGOP ISION FROM THE OWNER. THIS DOCUMENT IS CONSIDERED AS ONE UNIT AND SHALL NOT BE CONSIDERED COMPLETE OR WHOLE IF DOCUMENTS ARE SEPARATED IN ANY MANNER. DOCUMENTS SHALL NOT BE SEPARATED FOR THE PURPOSES OF SUBMITTING PROPOSALS OR FOR SEPARATE PHASES OF CONSTRUCTION. 5. THESE DOCUMENTS ARE PREPARED FOR THE USE BY CONTRACTOR AND IN NO WAY, EITHER IN WHOLE OR IN PART CONSTITUTE ANY DIRECTION OR INSTRUCTION TO ANY CONTRACTOR WITH REGARD TO CONSTRUCTION METHODS, MEANS OR TECHNIQUES. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION WORK INCLUDING, BUT NOT LIMITED TO, SEQUENCE & TEMPORARY SHORING OF ALL EXISTING STRUCTURES & VERIFICATION OF EXISTING UTILITIES & SERVICES. 7. CONTRACTOR SHALL NOTIFY UTILITIES PRIOR TO COMMENCEMENT OF ALL WORK. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS, SUBJECT TO CITY AND UTILITY INSPECTOR'S FINAL APPROVAL. 8. CONTRACTOR SHALL CLEAN UP ALL PUBLIC RIGHT -OF -WAY AND PRIVATE DRIVEWAYS AFTER EACH WORK DAY. CONSTRUCTION VEHICLES SHALL NOT BLOCK PUBLIC TRAFFIC OR ENTRIES AT ANY TIME. CONTRACTOR SHALL WORK ACCORDING TO CITY'S ALLOWED SCHEDULES ONLY. TEROR :o entire arts does not aut le or ordinances• ilpt .t :cns Is acknm viedgd: DESIG \ER officewraps, inc. LORI SALEBA, DESIGNER YUKO MATSUURA, DESIGNER 570 KIRKLAND WAY SUITE 201 KIRKLAND, WA 98033 (425) 952-5393 FAX (425) 952 -5397 EMAIL: Iori @officewraps.com yuko @officewraps.com BULDI J DW\ FAMILY FUN CENTERS SCOTT HUISH 7300 FUN CENTER WAY TUKWILA, WA (503) 381 -9590 EMAIL: huwish @aoll.com SCOPE OFIVPRGV- ME \TS: CONSTRUCT TENANT IMPROVEMENTS FOR A 1,221 S.F. OFFICE, INCLUDING INTERIOR PARTITIONS, FINISHES, PLUMBING, ELECTRICAL WIRING AND LIGHTING. FIRE SPRMLER SYSTEV, PLUvBING & HVAC TO BE UNDER SEPARATE PER\1IT E� SEPARATE PERMIT REQUIRED FOR: I Mechanical Electrical Plumbing Gas Piping City of Tukwila _BUILDING DIVISION MEC V OD CO APICAL IFIED TRACTOR AXIOM COMMERCIAL CORP NICK GALLASH 13110 N.E. 117TH PL SUITE 312 WOODINVILLE, WA 98072 (206)335 -2770 LIC #: AXIOMCC997NH EMAIL: nick@axiomcommercialcorp.com ENERGY COMPLIANCE a. BASED ON THE DESIGN / BUILT DELIVERY OF THE MECHANICAL, ELECTRICAL AND PLUMBING TRADES OF THIS PROJECT, THE THERMAL PERFORMANCE DESIGN OF ALL BUILDING ENCLOSURE SYSTEMS IS PRELIMINARY AND WILL REQUIRE VALIDATION BY THE DESIGN / BUILD TRADES. i. THE DESIGN / BUILD CONTRACTORS WILL BE REQUIRED TO PREPARE AND SUBMIT ALL ENERGY COMPLIANCE DOCUMENTATION. b. THE FOLLOWING INSULATION R-- VALUES ARE PROVIDED WITHIN EACH DESIGNATED ENCLOSURE SYSTEM. PLEASE NOTE THAT THE R- VALUES LISTED ARE NOT FOR THE ASSMBLY, RATHER THEY ARE FOR THE INSULATION COMPONENT WITHIN THAT ASSEMBLY. IN ALL INSTANCES THE OVERALL THERMAL PERFORMANCE OF THE ASSEMBLY (R OR U) WILL BE GREATER THAN THE VALUES LISTED. i. ROOF= R -20 ii. WALL, ABOVE GRADE= R -19 iii. WALL, BELOW GRADE= R -10 IV. SLAB ON GRADE= NO INSULATION PROVIDED BELOW THE SLAB ON GRADE. c. THE GLAZING SPECIFIED MEETS THE FOLLOWING CRITERIA. A GLAZING OPTION WILL BE SELECTED BASED ON AN ANALYSIS OF THE OVERALL ENVELOPE PERFORMANCE: i. TOTAL WALL AREA= 8,305 S.F. ii. TOTAL GLAZING AREA 1,716 S.F. iii. % OF GLAZING AREA= 20.6% IV. GLAZING OPTION A - CLEAR INSULATED 1. SOLAR HEAT GAIN COEFFICIENT= .70 2. SHADING COEFFICIENT= .81 3. SUMMER U= .55 4. WINTER U= .48 V. GLAZING OPTION B - LOW E INSULATED 1. SOLAR HEAT GAIN COEFFICIENT= .45 2. SHADING COEFFICIENT= .52 3. SUMMER U= .36 4. WINTER U= .33 Vi. NOTE THAT AWNINGS AND RECESSED OPENINGS ARE ALSO PROVIDED AS A DESIGN ELEMENT TO REDUCE THE AMOUNT OF HEAT GAIN AT THE STOREFRONT. d. VAPOR BARRIERS ARE SPECIFIED FOR THE ROOF, WALL OR FOUNDATION SYSTEM. ASSESSOR'S PARCEL \I,NB 242304909201 SITE & LOT COVERAGE TOTAL SITE AREA: N/A ,IMPERVIOUS AREA: N/A BUILDING ENVELOPE AREA: N/A LOT COVERAGE: N/A TI/ BUILDING STATISTICS NUMBER OF STORIES : 1 OCCUPANCY CLASSIFICATION : B- BUSINESS OCCUPANCY LOAD :13 (1,221 SF / 100 SF = 13 OCCUPANTS) NUMBER OF EXIT REQUIRED : 1 NUMBER OF EXIT PROVIDED : 1 BUILDING TYPE: TYPE -V -B SPRIBKLERED AREA OF SPACE TO BE REMODELED: 1,221 SQFT CONSTRUCTION VALUE: $ 36,630.00 PAR41I\G INFORMATION STANDARD-73 COMPACT - 5 ACCESSIBLE- 4 ZONI\ G \FORMATIO JURISDICTION: CITY OF TUKWILA, WA ZONING : CITY OF TUKWILA, WASHINGTON 98188 ZONING DESIGNATION CAI-COMMERCIAL LIGHT INDUSTORIES SETBACK REQUIREMENTS: N/A BUILDING HEIGHT PERMITTED: N/A PROPOSED BUILDING HEIGHT: N/A TRANSPORTATION . M N E T ` A N CODE COMPLIA\C I\FORMATIO\ BUILDING CODE: 2006 INTERNATIONAL BUILDING CODES 2006 WA STATE ENERGY CODE -R: AMERICAN NATIONAL STANDARD - AN I A1..te711 N2(t "NOTE: REVISION NUMBER 0 SUBMITTAL ITEM NUMBER This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. fiZ - Fo tit co or uTp a a en o Y v ▪ o: 5514 REGISTERED ARCHITECT BLAKE P. BOLTON STATE OF WASHINGTON DATE: 7/26/2007 REVISIONS BY: 9/ 1 2/07 YM SCALE: AS NOTED SHEET: PERMIT SET A 1.0 OF: 3 csa 24'-2" 25-0' 16'-8 16'-8" 24' -2° to GENERAL NOTES 1. THIS SET REPRESENTS "THE PERMIT DRAWINGS" AND IS INTENDED TO SHOW MINIMUM REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CONSTRUCTION NECESSARY FOR THE COMPLETE INSTALLATION OF ALL OPERATING SYSTEMS, MATERIALS AND FINISHES IN ACCORDANCE WITH MFR.'S RECOMMENDATION. CONTRACTOR SHALL THOROUGHLY REVIEW DRAWINGS, SPECIFICATIONS AND OWNER'S REQUIREMENTS. 2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR TO BID. DISCREPANCIES IN DIMENSIONS, DRAWINGS, GRAPHIC REPRESENTATION AND ACTUAL FIELD MEASUREMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER. 3. CONSTRUCTION SHALL BE BASED ON THE CITY APPROVED PLANS AND OWNER'S COMMENTS. THE APPROVED PLANS ARE TO REMAIN ON SITE AT ALL TIMES FOR USE BY ALL INVOLVED TRADES AND INSPECTORS. 4. THIS SET OF DRAWINGS SHALL NOT BE COPIED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN CONSENT PROJECT DATA: STREET ADDRESS FAMILY FUN CENTER WORLD HEADQUARTERS SCOTT HUISH 7100 FUN CENTER WAY TUKWILA, WA LEGAL DESCRlPTIOn X07- 286 242304 92 PORTION OF W OF SECTION 24 -23 -04 BEGIN INTERSECTION OF 2M LINE OF PRIMARY STATE HIGHWAY NO 1, GREEN RIVER INTERCHANGE UNDER KC SUPERIOR COURT CAUSE NO 596089 STA POC (2M) 134 +28.56 WITH A -LINE STA POT (A) 102 +82.12 WITH STATE OF WASHINGTON DEPT OF TRANSPORTATION SR 405 GREEN RIVER INTERCHANGE R/W STA 99 +00 TO STA 120 +00 SHEET 2 OF 2 REVISED DECEMBER 31, 1992 TH N 42 -30 -02 E ALONG CA OF SAID A -LINE 88.55 FT TO STA 103 +70.67 OF SAID A -LINE TH N 47 -29 -58 W 60 FT TO POINT ON NLY R/W OF SAID PRIMARY STATE HIGHWAY NO 1 SAID POINT BEING BEGINNING OF CURVE CONCAVE TO SOUTH RADIUS OF 163 FT AND ALSO BEING POINT OF BEGINING TH NLY, ELY & SLY ALONG SAID R/W ON ARC OF SAID CURVE THRU C/A 0 64 -48 -29 184.37 FT TH LEAVING SAID R/W & BEARING N 21 -14 -41 E 38.16 FT TH N 64 -48-08 W 5.90 FT TH N 22 -58 -18 W 1 66.10 FT TH N 22 -01 -42 E 229.49 FT TO POINT ON ORDINARY HIGH WATER LINE OF GREEN (WHITE) RIVER AS APPEARED ON AUGUST 11, 1997 TH ALONG ORDINARY HIGH WATER OF SAID RIVER THE FOLLOWING COURSES AND DISTANCES S 70-00-00 W 39.06 FT TH S 73-00-00 W 65 FT TH S 67- 00--00 W 100FT TH S 57 -40 -00 W 30 FT TH 63 -50 -00 W 35 FT TH S 56 -30 -00 W 100 FT TH S 51 -00 -00 W 50 FT TH S 35-40-00 W 40 FT TH S 39 -00 -00 W 60 FT TH S 52 -20 -00 W 50 FT TO NELY R/W FOR 2M -LINE TH SLY ALONG R/W TO ITS INTERSECTION WITH NLY R/W OF SAID A - LINE TH N 42 - 30 - 02 E 9.42 FT TO POINT OF BEGINING - AKA ADJUSTED PARCEL 1 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0028 RECORDING NO 9806309017 DOOR. SCHEDULE LOCATION ODOR FRAME H0 GROUP REMARKS NO. SIZE TYPE MAIN ENTRANCE 1 EXISTING Q EXISTING LOCKSET DOOR CLOSER "THIS NOTED AS: DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" RESTROOM 2 1 3/4" x 3' -O" x 7' -0" 0 FLUSH —0 U PRIVACY DOOR CLOSER, WALL STOP, COLOR: T.B.D. CONFERENCE 3 1 3/4 x 3' -0" x 7' -0" N/A SPECIAL WALL STOP, GLASS DESIGN: T.B.D. OFFICE 1 4 1 3/4" x 3' -0" x T--0" 0 U LOCKSET WALL STOP, GLASS DESIGN: T.B.D. OFFICE 2 5 1 3/4" x Y -0" x 7-0" © O LOCKSET WALL STOP. GLASS DESIGN: T.B.D. OFFICE 3 6 1 3/4" x 3' -O" x T -O" © © LOCKSET WALL STOP. GLASS DESIGN: T.B.D. DOOR NOTES: 1. SUBMIT KEYING SCHEDULE AND HARDWARE SAMPLES FOR APPROVAL. HDWR TO MATCH EXISTING. 2. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS. CABINETS. PLUMBING FIXTURES AND STORAGE FACILITIES SHALL HAVE A LEVER OR OTHER SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND WHICH DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE. 4. DOOR THRESHOLD SHALL NOT EXCEED 1/2" IN HEIGHT. 5. MAX. DOOR OPENING PRESSURES ARE LIMITED TO 8.5 L.BS. AT EXTERIOR DOORS AND 5.0 L135. AT INTERIOR DOORS. 6. VERIFY ALL DOOR SWINGS, HARDWARE AND KEYING REQUIREMENTS. 7. NEW DOORS AND FRAMES: FINISH T.B.D. 8. EXISTING DOORS AND FRAMES TO BE CLEANED AND REFINISHED. 9. All DOOR FRAMES TO BE CUSTOM GRADE. 10. NEW DOOR TRIM TO BE 2 -3/4" X 3/4" WITH EASED EDGE, UNLESS OTHERWISE SPECIFIED. 11. ACCESSIBLE RESTROOM SIGNAGE WI TACTILE CHARACTOR TO BE LOCATED ON PUSH SIDE CF DOOR W/ CLOSERS AND WITHOUT HOLD-OPEN DEVICE. TACTILE CHARACTOR SHALL BE 48 INCH MIN., 60 INCH MAX. ABOVE FLOOR. DOOR HARDWARE TYPE OF LOCK SPECIFICATION Passageway SCHLAGE: AL Series Lever: NEPTUNE Finish: #626 Satin Chromium Plated Privacy (Restroom) SCHLAGE: AL Series Lever: NEPTUNE Finish: #626 Satin Chromium Plated NOTES: 1. Provide standard weight commercial door hinges 2. All doors with closers to have ball bearing hinges 3. Provide door stops at appropriate locations 4. See Material and Finish Schedule for color and finish of doors 5. Door hardware finish: Satin Chrome 6. Alternate Manufacturers may be selected with designer's approval RECEPTION r . .1 . . • • m 01 IN UTILITIES p MI I UTILITIES • In .i RI Ie in .I • in I■ 1 I ii in in IN J IN It I I I. IS . IN IN IN i• II • I. 1. II ��1 IN IN . Q I• I. IN IN E CONFERENCE FE F ;. 103 II u u 1• 1. I• IN IN IN 111 II IN u •a in IN IN IE IN I. IN I II /" J N • I; I. ;� / I. I: IN In 1. IN IN 1. IN IN 1. I. ▪ \ I. IN IN IN \ IN \ 1a4 IN IX II 1 • IN _. — __..._____..— .._...__ . ..............� I. �I IN N I: IN IN IN 1 11 In 1■ IN IN 'U • IN IN IN OFFICE 3 OFFICE 1 U5E EXISTING 3TON ROOF TOP MAC. DUCT WORK DI~5IGN WILT UNDER. MECHANICAL PERMIT. OFFICE 2 CV Zzr CNI - orb E t7 C•I CV CD 4' -2" 3 ' -0 " 13 3 ' -0 " � 11 24' -2" 23' -9" 5'-6" M 9) C1D LC) r co HD. D[ HD" DI HD. Dl . HD, DI STORE DOOR TEMPERED GLASS NOT TO SCALE DOOR TYPES FRAME LESS FULL GLASS WI RE -LITE TEMPERED WALL LEGEND NEW PARTITION WALL WALL MOCKING DEMISING /SOUND WALL EXISTING WALL FULL GLASS WI RE -LITE TEMPERED NO SCALE s C.W.D. ON 3.5` MEr. STUDS ®18` O.C. W/ RC-1 CHANNEL (te' O.C.) & SOUND ATTENUATION BLANKET a INN DEMISING WALL TYP. BETWEEN TENANT SPACES INSTALLATION NOTES: NON -RATED WALL TIP. INT. PARTITIONS USE DEFLECTION TRACKS © TOP OF PARTITIONS TO STRUCTURAL SUPPORTS ABOVE TYPICAL INTERIOR WALL SECTIONS '!t HOLLOW METAL. FLUSH DOOR 2 3/4" k PLOUGH I/2" DOOR TRIM NOT TO SCALE 3/ 4" METAL PANEL R -19 BATT INSUL. W/) VAPOR BARRIER (TYP) T.O.M. T-4" F.F. O , -O " MASONRY WALL TILE AIR GAP 5/ 8" DENS -GLASS SUBSTRATE 4" SPLIT FACE CMU VENEER BROOM FINISH SECTIO TTTT TTrTTT - • • tTT� SLOPE CvU VENEER PJ bo7 Z8& (2)LAYER IN R -10 P 2" ROOF INSULATION W/ VAPOR BARRIER (TYP STEEL MEMBERS PER STRUCT) RECEIVED SEP .2 6 2007 PERMIT CENTER This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. REGISTERED ARCHITECT BLAKE P. BOLTON STATE OF WASHINGTON £ ■ 5514 DATE: 7/26/2007 REVISIONS BY: 9/ 1 2/'07 YM SCALE: AS NOTED SHEET: PERMIT SET A 2.0 OF: H.M. FRAME TYPES NOT TO SCALE I /2" I DOOR OPENING EASED EDGE R =7 RADIUS TO BE PLACED AT OUTSIDE EDGE of DOOR OPENING ROOM FINISH SCHEDULE ROOM FLOOR BASE WALLS CEILING NOTES NO. NAME WALL SWITCH W /MOTION SENSOR ( +48 ") NORTH EAST SOUTH WEST MATL HT. RECESSED FLUORESCENT DOWNLIGHTS 32W/28W COMPACT FLUORESCENT LAMP INDICATE 24 —HOUR FIXTURE W/ EMERGENCY BATTERY BACKUP WALL SCONCE I CONCRETE I STONE TILE IDA CARPET VINYL SHEET HARDWOOD 6" STONE TILE [4'WOOD BASE 4" RUBBER BASE COVED BASE SEE FLOOR PLAN [GYM /PAINT SCRUBABLE VINYL WINDOW WALL SEE FLOOR PLAN INIVd /8MO SCRUBABLE VINYL WINDOW WALL SEE FLOOR PLAN GWB /PAINT SCRUBABLE VINYL WINDOW WALL SEE FLOOR PLAN GWB /PAINT SCRUBABLE VINYL WINDOW WALL INIVd /8M01 ACOUS. PANELS EXPOSED STRIJCT. AFF 101 RECEPTION 0 0 0 0 0 0 0 0 1 0' -0" A.F.F. 102 RESTROOM 0 0 0 0 0 0 0 B' -6 A.F.F. SPLASH GUARD 48" A.F.F. 103 CONFERENCE 0 0 0 0 0 0 0 9' -6" A.F.F. GM SOFFIT ® 9' -0" AND 8' -6 A.F.F. 104 OFFICE 1 O 0 0 0 0 0 0 0 10' -0" A.F.F. 105 OFFICE 2 0 0 0 1 O' -O` A.F.F. 106 OFFICE 3 0 0 0 10' -0° A.F.F. RC' ._ LEGE WALL SWITCH ( +48 ") WALL SWITCH W /MOTION SENSOR ( +48 ") 2' X 4' RECESSED FLUORESCENT, ELECTRONIC BALLAST, T -8 LAMPS RECESSED FLUORESCENT DOWNLIGHTS 32W/28W COMPACT FLUORESCENT LAMP INDICATE 24 —HOUR FIXTURE W/ EMERGENCY BATTERY BACKUP WALL SCONCE ® INCANDESCENT PENDANT FIXTURE UNDERCABINET FLUORESCENT STRIP + DISPLAY LIGHT ® SURFACE MOUNT EXIT SIGN F Ioo EXHAUST 100 CFM BATTERY PACK EMERGENCY LIGHTS Ci) CEPTION RCP / LIG SCALE: 1/4 " =1' -0" OFFIC 3 DTI \G PLA\ CEILING LEGEND 1- + + + + + + + + + -F + 4 4 + + + 4 + + + + + + + 4 + + + T4 . TX 4' GRID @ 1O' -O" A.F.F. 2'X 4' GRID @ 9'-6" A.F.F. GWB CEILING @10'-0" A.F.F. GWB CEILING @ 9 -0" A.F.F. GWB CEILING @ 8-6" A.F.F. `�l 7 , EXISTING ROOF STRUCTURE NOT TO SCALE 1MM111IIll1I11111IA #II14 NOT TO SCALE CEILING EDGE TRIM ACOUSTICAL CEILING TILES IN SUSPENDED T BAR GRID SYSTEM 1• PER RCP I PER RCP %" TYPE'X' GYP, BD. ON METAL FRAMING SYSTEM — YP. SOFFIT DETAIL 31/2°W 20 GAUGE) METAL STUDS @ 5-0° O.C. TYP., FASTEN TO TOP OF WALL & EXIST. CONST, W/ 2 - #10 GA. SCREWS RUNNER CHANNEL RUNNER CHANNEL - 45'MAX. 2' BERC CLIPS WITH 7/8' ARMSTRONG WALL MOLDING (#7800) (SEE ARMSTRONG SEISMIC INSTALLATION INSTRUCTIONS) 518° TYPE 'X' GYP. BD. EACH SIDE 7 ,..„--- WITH 3 5189° x 25 GA. METAL STUDS @2A° D. FASTEN SOT. OF STUDS TO FRAMING W! 2 -#10 GA. SCREWS 0,C. WOOD WOOD OR RUBBER BASE SEE FINISH SCHEDULE 12 GA.1ThSION WIRES (TYP -) HEAVY DUTY MAIN RUNNERS @48 "O,C..TYP. FLOOR FINISH SEE FINISH SCHEDULE ROOF STRU RE REF. S CEILING SEISMIC REINF. DETAIL TYP. ROOF RCP GENERAL NOTES 1. PROVIDE AND INSTALL EMERGENCY EXIT SIGNS, HORNS, AND EMERGENCY LIGHTING AS PER CODE. VERIFY LOCATION WITH DESIGNER. 2_ PROVIDE AND INSTALL NEW 2 X 4 GRID WITH ACCOUSTICAL PANELS TO BE ARMSTRONG / DUNE. 3. CONTRACTOR TO FURNISH AND INSTALL UNDERCABINET LIGHTING AS SHOWN ON RCP. FIELD VERIFY LOCATIONS AND SIZE WITH DESIGNER. 4. DESIGNER IS NOT RESPONSIBLE FOR VENTILATION REQUIREMENT OF MEDICAL EQUIPMENT. VERIFY VENTILATION REQ WITH DOCTOR AND EQUIPMENT SPECIALIST WHEN APPLICABLE_ 5. PENDANTS TO BE FIELD LOCATED. VERIFY DROP HEIGHT AND LOCATION W/ DESIGNER BEFORE INSTALLATION. 6. 7. SEISM! W/ 12 SECUR SUBMIT LIGHTING SCHEDULE TO DESIGNER FOR APPROVAL. FIRE REQUIREMENTS UNDER SEPARATE PERMIT. PROVIDE AND INSTALL ALL NECESSARY FIRE REQUIREMENTS PER CODE. (INCLUDING FIRE EXTINGUISHER) 8 . VERIFY LEAD TIMES FOR LIGHTING AS SOME PRODUCTS MAY HAVE EXTENDED LEAD TIME. STRUM': 3/4° DIA. CONDUIT TENSION WIRE & SLEEVE SLEEVE W/ 2- # 10 GA. SCREWS TYPICAL ACOUSTICAL CEILING: PROVIDE SEISMIC REINFORCING PER 2003 IBC AND CISCA GUIDELINES FOR SEISMIC ZONES 3-4 SEISMIC STRUCTS @ 12'-0° EA. WAY. BRACED W/ 4 -12 GA. WIRE PER STRUT INSTALL PERIMETER WIRE AT ALL T -BARS PROVIDE 2 -12 CA. LIGHT WIRES PER LIGHT FIXTURE (1YP.) i34 WHEELCHAIR TURNING SPACE NOT TO SCALE 39 -41 NOT TO SCALE 54 mm 12 42 man Side Wall I. — 00 v i Ln m CO CO CO GRAB BARS © W/C toilet paper c E C9 —3G mm —18 15- mm __ clear floor space Back Wall 5514 REGISTERED ARCHITECT RO BLAKE P. BOLTON STATE OF WASHINGTON nr �� yA a - n om J GO mm CLEAR FLOOR SPACE @ W/C NOT TO SCALE m m m TABLE 606.7 ICC / ANSI A -117.1 -2003 MAXIMUM REACH DEPTH AND HEIGHT MAXIMUM REACH DEPTH MAXIMUM REACH HEIGHT .5 INCH (13mm) 48 INCH (1220mm) 2 INCH (50mm) 46 INCH (1170mm) 5 INCH (125mm) 42 INCH (1065mm) 6 INCH (150mm) 40 INCH (1050mm) 9INCH 11INCH (230mm) (280mm) 36 INCH 34 INCH (915mm) (865mm) RECENED SEP 2 6 2007 PERMIT CENTER This set of drawings shall not be copied in whole or in part without prior written consent from the owner. This document is considered as one unit and shall not be considered complete of whole if documents are separated in any manner. Documents shall not be separated for the purpose of submitting proposals or for separate phases of construction. a) DATE: 7/26/2007 REVISIONS BY: SCALE: AS NOTED SHEET: PERMIT SET A 3.0 OF: 3 0 0 LL FAMILY FUN CENTER WORLD HEADQUARTERS CEILING DETAILS 7100 FUN CENTER WAY COPYRIGHT