Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D07-290 - DRESS BARN - TENANT IMPROVEMENT
DRESS BARN 17250 SOUTHCENTER PY D07 -290 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tulovila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D07 -290 Occupant/Tenant: DRESS BARN Building Address: 17250 SOUTHCENTER PY, SUITE NO. 112 Parcel No.: 2623049117 Property Owner: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA 98006 Use: RETAIL Occupancy Group/Division: M Type of Construction: N -B Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: 203 II - 30-- e007 DATE THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: DESCRIPTION OF WORK: TENANT IMPROVEMENT doc: IBC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2623049117 17250 SOUTHCENTER PY TUKW DRESS BARN 17250 SOUTHCENTER PY , TUKWILA WA WIG PROPERTIES LLC-SS 4811 134TH PL SE , BELLEVUE WA 98006 Contact Person: Name: ROXANNE BRUNO Address: 1625 W 8510 S , WEST JORDAN UT 84088 Phone: 310 465 -9784 Contractor: Name: ARGONAUT BUILDERS INC Address: 50 BIRCH AV , LITTLE SILVER NJ 07739 Phone: 732 -933 -0099 Contractor License No: ARGONBI934N2 Value of Construction: $55,000.00 Type of Fire Protection: SPRINKLERS Type of Construction: IVB DEVELOPMENT PERMIT * *continued on next page** Permit Number: Issue Date: Permit Expires On: Expiration Date: 08/22/2009 Fees Collected: International Building Code Edition: Occupancy per IBC: D07 -290 09/26/2007 03/24/2008 $1,392.78 2006 0019 D07 -290 Printed: 09-26 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City 6,.iTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D07 -290 Issue Date: 09/26/2007 Permit Expires On: 03/24/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Authorized Signature: "�/ "�/" ` f7�- Date: Permit Center gna g) I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of wor I am authorized to sign and obtain this development permit. Signature: . /% Date: / ' a � Print Name, e I ,& This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC-10 /06 D07 -290 Printed: 09 -26 -2007 City of Tukwila Parcel No.: 2623049117 Address: 17250 SOUTHCENTER PY TUKW Suite No: Tenant: DRESS BARN 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D07 - 290 Status: ISSUED Applied Date: 08/06/2007 Issue Date: 09/26/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). doc: Cond -10/06 D07 -290 Printed: 09 -26 -2007 City of Tukwila 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: ** *FIRE DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 25: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 26: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 27: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 28: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress doc: Cond -10/06 D07 -290 Printed: 09 -26 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 29: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 30: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 31: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 32: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 33: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 34: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: In occupancies of Groups A, E, I and R -1 and dormitories in Group R -2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall be flame resistant in accordance with NFPA 701 or be noncombustible. Where required to be flame resistant, decorative materials shall be tested by an approved agency and doc: Cond -10/06 D07 -290 Printed: 09 -26 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us pass Test 1, as described in NFPA 701, or such materials shall be noncombustible. Reports of test results shall be prepared in accordance with NFPA 701 and furnished to the fire code official upon request. (IFC 805.1, 805.2) 41: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 43: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** D07 -290 Printed: 09 -26 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 D07 -290 Date:,/ ... 7 ordinances governing or local laws regulating Printed: 09 -26 -2007 Property Owners Name: Mailing Address: 'two' CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tulavila.wa.us Building Permit No. 1701 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. 901-011 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 2- j1 sw-t "111 Site Address: 1 2') n � COnker fk-/Q Suite Number: Floor: Tenant Name: Or e s 5 P w W y\ New Tenant: Yes ❑ ..No CONTACT PERSON - who do we contact when your permit is ready to be issued j • • b Day Telephone: 3 I f) 1 .4 (p1 J _ 1 7 gq �/ Mailing Address: I • 25 W rib 5 �ts't. Jo �4� V \ s� W a City E-Mail Address: O) WrP b acATIYk rcial ?rrni - O, azFuuTer: itt stotp'?(DO(a Name: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Mailing Address:_ Company Name: DA U N I Q:\Applieatians\Fonts- Applications On tine\3-2006 - Permit Applicatioadoc Revised: 9 -2006 bb City c,a ARCHI'T'ECT OF RECORD - MI plans must be wet stamped by Architect of Record 1,` City Contact Person: Oat V 1 d I J D I -b v\J Day Telephone: E -Mail Address: Fax Number: State 2ity Site ---y _ Contact Person. _ Day Telephone: 1 E - Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Zip 0775 Zip I Itl U2 69 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 BUILDING PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ /J/ ()O Existing Building Valuation: $ � Scope of Work (please provide detailed information): to r YC ��'e ` C* 'C 1 S 1 ityleA V1 t. `519i 1(-P- I , q 11 V V� Q:\Appliatiaa3\Fo mn- Applianons On LineO -2006 - Permit Applicationdoc Roviand: 9 -2006 bh Will there be new rack storage? ❑ Yes Pci.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/RAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x II "paper including quantities and Material Safety to Sheets. SEPTIC SYSTEM ❑ On - site Septic System — For on - site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 19 r v M 2 " Floor 3'" Floor Floors thnr Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ /J/ ()O Existing Building Valuation: $ � Scope of Work (please provide detailed information): to r YC ��'e ` C* 'C 1 S 1 ityleA V1 t. `519i 1(-P- I , q 11 V V� Q:\Appliatiaa3\Fo mn- Applianons On LineO -2006 - Permit Applicationdoc Roviand: 9 -2006 bh Will there be new rack storage? ❑ Yes Pci.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/RAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x II "paper including quantities and Material Safety to Sheets. SEPTIC SYSTEM ❑ On - site Septic System — For on - site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PUBLIC WORKS PERMIT INFORMATION - 206 - 433 -0179 Scope of Work (please provide detailed information): Sewer District 0 ...Tukwila ❑ ...Sewer Use Certificate ❑ ...Total Cut ❑ ...Total Fill Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided ❑...ValVue 0... Sewer Availability Provided Septic System: 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ubmitted with Application (mark boxes which apply): ] ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ... Construction /Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ..Sanitary Side Sewer ..Cap or Remove Utilities ..Frontage Improvements ..Traffic Control ..Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. >, ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public > , , > ❑ . ❑ . ❑ . ❑ . Call before you Dig: 1- 800 - 424-5555 . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ .. Highline ❑ .. Renton WO # WO # WO # Private Private ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑ .. Seattle ❑...Deduct Water Meter Size ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip Q:Npplicalicas\Fomn- Applications On Line\3 -2006 - Permit Application:doc Revised: 9 -2006 6b Page 3 of 6 Print Name: 0 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. 13uilding and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.32 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AUTHORIZED ENT: Signature: GRIA1 /r" Mailing Address: 1 (P 2. r ij r Date Application Expires: od , �� AA l/tJt� Date Application Accepted: tI(i On tine\3 -7006 - Permit Application.doc Revised: 9.7006 bh Date: g 1:3 1 - 7 Day Telephone• 0 "1 1 7sL1 S e-sk- ovdUv� en W � v�r glen City State Zip Staff Initials (.! Page 6 of 6 i Parcel No.: 2623049117 Permit Number: D07 -290 Address: 17250 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 08/06/2007 Applicant: DRESS BARN Issue Date: Receipt No.: R07 -02104 Initials: WER Payment Date: 09/26/2007 03:56 PM User ID: 1655 Balance: $0.00 Payee: ARGONAUT INC TRANSACTION LIST: Type Method Description Amount Payment Check 26071 845.88 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Account Code Current Pmts 000/322.100 841.38 000/386.904 4.50 Total: $845.88 Payment Amount: $845.88 :3287 09/27 a 1O TOTAL 845,3C doc: Receiot -06 Printed: 09-26 -2007 RECEIPT NO: R07 -01608 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• //www.ci.tukwila.wa.us Payee: COMMERCIAL, PERMIT GROUP, INC. 7= 546.90 EL07 -365 61.50 TOTAL: 608.40 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT Initials: JEM Payment Date: 08/06/2007 User ID: 1165 Total Payment: 608.40 SET ID: S000000822 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 1459 608.40 TOTAL: 608.40 Account Code Current Pmts 000.345.832.00.0 61.50 000/345.830 546.90 TOTAL: 608.40 1144 08/07 'i. t OTAL 608.40 Proje� �L�' �SS A7 41 Type of Ins ection: ilv4 / Address: / 72 5 Sepn(0 /4/ /J� Date Called: Special Instructions: Date Wanted: /u� /C Requester: Pho a No: - 7 -9s 2 - Z 7 INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 COMMENTS: Insp- or: $58.0 REINSPECTION FEE RE at 6300 Southcenter Blvd., pal proved per applicable codes. El Corrections required prior to approval. t No.: r rvA ;-t � €-\e. nce ztc • 'Date: Date: ..-- ) 1 T IRED. rior to inspection, fee must be uite 10t Call the schedule reinspection. ..� •il33-- �`^�::iL'e- i.icar'...`. - _r' ... "_.— -• .X__ _ }.�,.,..u. COMMENTS: ( / ) 7 : i' 41 ; R(--poV) . r ,--,0 I L) (/ ; L,Y1 I ('iwe' /_6 hl i/ 00— 2& r Special Instructions: Date Wanted: m. Requester: Phone No: (4) -744 7 `...,, Project: Di .,<› D)P, f d Type of InspEction: i I - - i ik) A- I r : , 4,,, Address: _ , 1 SN-Ilvigar Date Called: Special Instructions: Date Wanted: m. Requester: Phone No: (4) -744 7 INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 El Approved per applicable codes. Do7-2W 14 Corrections required prior to approval. IDate: A A ..e" I / 0/2_y/e7 REINSPECTIO fEE REQUIRED. Prior to inspection, fee must be at 6300 Southcentek Blvd.. Suite 100. Call the schedule reinspection. IDate: COMMENTS: Type of Inspection: / 7 �j7 /S7`i cl 0"/ / It — // f' /i r'V /J / l - /'r/1 Special Instructions: ' � � ) 11 ! -� r < 7 ,c:� It 5 /C 1 i , ; r c_ / / et.../ Requester. t✓r SS ,...A._ r2�/IS /'� <c�t ✓1 x ■ 4- 0 iebu AJJ-) hr. do b l /42 e / ro04/7 1 Plus i3(‘ Pvsj- / �v / /nig i 71/ 6,7)� Chi / i, bi/ h rn is - f < o v , d, (r i dik ifef 1 ?e- iii t Proj t: • 2, - 5S & ?ice Type of Inspection: / 7 A dre _ /7Z505:D'(X , e Called: / Special Instructions: Date Wanted: a, / p/7 3/x`7 c m. Requester. Phone No: 6' 6 7 - Z `e7 ,r INSPECTIOWN0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Corrections required prior to approval. INSPECTION RECORD etain a copy with permit Inspe • 58.00 REINSPE ON E REQUIRED. Prior to inspection, fee must be paid at 6300 Sout cen er Blvd., Suite 100. Call the schedule reinspection. Dat l 'Receipt No.: 'Date: Proj t: I- 3 ,e// Ai Type of Inspection: / / e .9, - ,7 .✓e__ Address: Date C II d: Special Instructions: Date Wanted: 6 1 z 7 D7 C. a m p.m. Requester: Phone No: 6 6 7 - (f--)5 7 -2 V INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 z) r2 Z5 PERMIT NO. V- (206)43 1 -3670 COMMENTS: Approved per applicable codes. El Corrections required prior to approval. Inspector: �/ $58. EINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: YES Lf-r: `"s'+ , ,. -N+ 7 COMMENTS: Type of Inspection: ,E'rY1'e i- rr c / A .f h7 4 f Address: / 7e v 5 cµ- lice .� .1 < .,. Pill -Y Suite #: Contact Person: Permits: es) - t-" - t1 C `/' $ 'n 5 4/. Phone No.: ,. /V / h* 1411-C-' / IZ' 0 5"-7' r ! 44 G 6 r ef ` C r'l, S . . 1 2 :. 7 ..) .r d 0 -r 407- 2 7 ©, et_ AV Srp -u 644110 )Per 01- 4- C— s 4,1c) 4.5 De> 7- ZM r . Project: 02e5.5 6484 Type of Inspection: ,E'rY1'e i- rr c / A .f h7 4 f Address: / 7e v 5 cµ- lice .� .1 < .,. Pill -Y Suite #: Contact Person: Permits: Occupancy Type: Special Instructions: Phone No.: Needs Shift Inspection: t Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT st, Tukwila, Wa. 98188 206- 575 -4407 Word /Inspection Record Form.Doc 1/13/06 7- ZWeD iffursitiff PERMIT NUMBERS Corrections required prior to approval. J Inspector: $6, / Date: i e; r q Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 2J�SUM . • Project:S umrriarj 2001 WaaWng cn Slate riavesWenOat EnorpyCods Compnanco Forms Washington State Nonresidential Energy Code Compliance Form Project Info Project Address grass Barn 17250 Southcentor Parkway, Suite 112 Tukwila, Wa. Applicant Name: Robert W. Farris Jr., Sanderson Engineer's Inc. AppllcantAddress: 8325 Lenexa Dr Suite 100 Lenexa, XS $6214 Applicant Phone: (913)307 Date 7/13/2007 For Building Department Use Pl :n r I :. t. c. rya co p No. Revised May2005 ;t A. CODE COMPLIANCE app E� R SEP 2, 4 200 CORRECTION LTR #.____4_ RECF V,VED SEP 12 2007 t 7 ". 7--Ct fail :;E TE_P, maximum m m Proposed Lighting wattage Location Number of Watts/ Watts Fixture Description Fixtures Fixture Proposed a (floor /room no.) 91 63.0 5733.0 a -2 32 33.0 1056.0 F 2 60.0 120.0 c 12 52.0 624.0 A 13 60.0 780.0 E 4 80.0 320.0 C 4 52.0 208.0 T2 3 82.0 156.0 T4 E7C: W5 (SHOW WINDOW) 18 T2 ExEt PT (shoe► WINDOW) 2 xs•2S A EPT (SNOW WINDOW) 14 T4 (62} 2 2400.0 4800.0 max 2 1800.0 3600.0 .r -. -. e.......ee.r Waite may net exceed Total Allowed Watts for Interior Total Proposed Watts 17397.0 2006 Washington State Nonresidential Energy Code Compliance Form inferior Lighting Summa 2006 Washington State Nonr hdon0at Energy Code Compliance Fame Project Info Project Address 11250 SOUTHCENTER AVE. TtnG4ILA, WASHINGTON 98186 ss Applicant Name: vINCE px»so Applicant Address: 5325 LENEXA DRIVE LENEXA, xS 66214 Applicant Phone: 913 -742 -53 Date 7/13/2007 For Building Department Use Project Description Compliance Option O Prescriptive 0 Lighting Power Allowance 0 Systems Analysis {See Qualification Checklist (over). Indicate . Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions 1 ❑ No changes are being made to the fighting (check appropriate box -sec. 1132.3) ❑ Less than 60% of the fixtures new, installed wattage not Increased. & space use not changed. d T 1,4 F rom Table 15 -1 (over) - ❑ New Building CI Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section •513 for controls and commissioning requirements. Notes: 1. For proposed Fixture Description, Indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type Included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast Information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard-wired ballasts only, the default table In the NREC Technical Reference Manual may also be used. For track fighting, list the greater of actual luminaire wattage or length of track multiplied by 50. or as applicable, the wattage of current limiting devices or of the transformer. 3. List an fixtures. For exempt fighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form inferior Lighting Summa 2006 Washington State Nonr hdon0at Energy Code Compliance Fame Project Info Project Address 11250 SOUTHCENTER AVE. TtnG4ILA, WASHINGTON 98186 ss Applicant Name: vINCE px»so Applicant Address: 5325 LENEXA DRIVE LENEXA, xS 66214 Applicant Phone: 913 -742 -53 Date 7/13/2007 For Building Department Use Project Description Compliance Option O Prescriptive 0 Lighting Power Allowance 0 Systems Analysis {See Qualification Checklist (over). Indicate . Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions 1 ❑ No changes are being made to the fighting (check appropriate box -sec. 1132.3) ❑ Less than 60% of the fixtures new, installed wattage not Increased. & space use not changed. d T 1,4 F rom Table 15 -1 (over) - ❑ New Building CI Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section •513 for controls and commissioning requirements. Notes: 1. For proposed Fixture Description, Indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type Included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast Information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard-wired ballasts only, the default table In the NREC Technical Reference Manual may also be used. For track fighting, list the greater of actual luminaire wattage or length of track multiplied by 50. or as applicable, the wattage of current limiting devices or of the transformer. 3. List an fixtures. For exempt fighting, note section and exception number, and leave Watts/Fixture blank. TABLE '15 -1 Unit Llgnitrtg rower MI1Uwciinas Use' LPA (Wisfl Use' LPA` (Mt) " ' " Automotive facility 0.9 Office buildings. office/administrative areas in facilities of other use types (Including but not limited schools, hospitals, Institutions, museums, banks, churches}``''" oo. a r_r . Convention center 1.2 Penitentiary and other Group 1-3 Occupancies Courthouse 1.2 Police and fire stations` Cafeterias, fast food establishmens ° , slbars 1.3 Post office Dormitory Dormitory y 1.0 Retail", retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.0 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', spaces' 1.0 Theater, motion picture 1.2 assembly Health clinic 1.0 Theater, performing arts 1.6 care Hospital, nursing homes, and other Group I -1 and 1-2 Occupancies 1.2 Transportation 1.0 H 1.0 Warehouses ", storage areas 0.5 Hotel ban. eticonference/exhibilion hair" Laboratory spaces (all spaces not classified laboratory' shall meet office and other appropriate 2.0 1.8 • Worksho• Parking garages 1_4 0.2 categories) Laundries N to t9 .' I- r Plans Submitted for Common Areas Only' Libraries' Main floor building lobbies' (except mall concourses) 1.2 Manufacturing facility Common areas. corridors, toilet facilities and washrooms, elevator lobbies .0.8 Museum Washington Slate NooresldenUat Energy Code Cespranea Faun 2006 Washington State Nonresidential Energy Code Compliance Form Interior "Li ummary (back GOT Revised July 20e7 Prescriptive Spaces Qualification Checklist Note:. If occupancy type is "Other and fixture answer Is checked, the number of fixtures In :ascots not limited by Code. Clearly Indicate these spaces on plans. N not qualified, do IPA Calculations. Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Other Lighting Fixtures: (Section 1521) 0 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non-lensed with a) 1 or 2 two lamps, b) reflector or louvers, o) 5.60 wall T -1, T-2, T -4, T.5, T-8 lamps, and d) hard-wired elec- tronic dimming ballasts. Screw-In compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < 150w c) electronic ballasts 3. LED lights. LPA) Footnotes for Table 15 -1 1) to cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use Is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified In the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be Increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/rt' may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Ughling Power Allowance for the court area is 2.60 W /fi 10) walls or at least three - quarter height partitions (transparent or provided d that the display window Is lighting for free-standing display where the lighting moves by oves with the display are exempt An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable In both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED; tungsten halogen, fluorescent. or high intensity discharge lamps. This additional lighting power Is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height. Is submitted, the square footage fora warehouse may be defined, for computing the Interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Tradable Maximum L•un:mera L. 6s. 8 ......b.. • Tradable Locations Description Allowed Watts per ft or per If Area (R perimeter (If) or # of items Allowed Watts x ft (or x If) • Total Allowed Watts Non - L raaavle 1v.uimai f.[au s-uwu•• c....,wb i7 ...._ - _ a - Non Tradable Locations Description Allowed Waits per ft or per If Area (1t perimeter (If) or # of items Mowed Watts x ft (or x If) NOn Lraaavie rrupuac4.4 a.wb b • • •4••••0" Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed iraaavte rrupuse s a.55 b • • k....w Location Fixture Description Number of Fixtures Watts! Fixture Watts Proposed T..mf onnncarl Warts may not exceed Total Allowed Watts for Exterior Total Proposed Watts r f 2006 Washington State Nonresidential Energy Code Compliance Form Exterior: Lighting��Summar� : T.G =EXT 2000 Washington Stale Nawsldential Energy Code CeMlknce Rains Revised July 2001 Project Info Pre) Addres: SOITNCENTER MIS. TOKNSLA, 1A881NGTON 98188 Name: VINCE MOM= Appi. Name 8325 LENEXA DRIVE LENEXA, TS 66214 Appi. Phone 913 -742 -5300 Date 7/13/2007 For Building Department Use Project Description 1 ❑ New ❑ Addition ❑ Alteration 0 Plans Included Refer to WSEC Section 1613 for controls and commissioning requirements. 'Compliance Option Q Lighting Power Allowance Q Systems Analysis Building Gi W r (luminatres> 100 Watts) 0 > 60iumensP ❑ Exemption (list) ❑ Controlled by motion Sensor_ _ (Alteration Exceptions I (check appropriate box - sec. 1132.3) 1 0 No changes are being made to the lighting • ❑ Less than 60% of the fixtures new, Installed wattage not Increased, & space use not changed. • ropOSea 9Vat[s may rw[ ewc Use mfgr listed maximum Input wattage. For fixtures wRh hard-w red ballasts only, the de fault table in the NREC Technical Reference Manual may also be used. Tradable Surfaces Uncovered Parking Areas (Lighting power Parking lots and drives 1 0.15 W /ft` • densities for uncovered building Building Grounds parking areas, grounds, building Walkways less than 10 feet wide 1.0 W/linear foot entrances and exits, canopies and overhangs and outdoor sales areas Walkways 10 feet wide or greater plaza areas Special feature areas 0.2W/11 maybe traded.) Stairways 1.0 W/11 .Building Entrances and Exits { Main entries 30 W/linear foot of door width Other doors 20 W/linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W/f Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft Street frontage for vehicle sales lots in addition to "open area" allowance 20 W/linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 we for each illuminated wall or surface or 5.0W/linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse Inspection 'stations at guarded facilities 1.25 W/& of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable ' Surfaces") Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive-through Parking near 24 -hour retail entrances 800 W per main entry Exterior: ummary (back) 2000 Wa$Nngton Stale NomesldenUai Energy Code Compliance kerns 2006 Washington State Nonresidential Energy Code Compliance Form TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised .kdy 2007 • • • • • 2006 Washington State Nonres denlitd Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Lighting.Powet'Allowance. djustmenfs "> rater 7/13/2007 Project Address 117250 aoUTECENTER AVE. Use this form If you are claiming any ceiling height adjustments for your Ughting Power Allowances for interior lighting. The Occupancy Description should agree With the Use listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet. 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA Is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding Allowed Watts per 9 location on LTG -SUM. Adjusted Li:hting Power Allowances (Interior Location (floor /room no.) Occupancy Description Mowed Watts per ft '• From Table 15-1 based on exceptions fisted in footnotes Ceiling Height for this room Revised July 2007 Ceiling Height limit Adjusted LPA for this exception** Watts per ft2 Lighting otcir 2008 WasNngtco Stets Novesidential P ans; ec Is Energy Code Complianos forms Revised July 2007 Project Address 17250 SOUTRCENSER AVZ . 1Date 7/13/2007 The following Information Is necessary to check a permit application for compliance with the fighting, motor, and transformer requirements in the 2006 Washington Slate Nonresidential Ene gy Code. Applicability I (yes, no, n.a.) I Code Section Component 'Information I Required I Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) 1513.1 Local control/access Schedule with type. Indicate locations 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans 1513.4 Display/exhib/special Indicate separate controls ' 1513.5 Exterior shut-off Schedule with type and features. Indicate location (a) timer w/backup Indicate location (b) photocell. Indicate location 1513.6 Inter, auto shut-off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto, switches Schedule with type and features (back-up, override capability); Indicate size of zone on plans 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) I 1514 Max. watts indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530-1532) 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types. lamps, ballasts, watts per fixture 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) I 1511 Disc motor efficiency MECH-MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) I 1540 'Transformers 'indicate size and efficiency • I 2006 Washin ton State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Ene • y Code Compliance Form Lighting; I1otor, and- Transfoirmer Permit Plans: Chec LT CHK 2006 Wasttngton State NoNUJdeThsi Energy Code Compliance Forms amber, Juty Lighting - General Requirements in Section 1512, Including 2, hall comply with this section. Where lighting Whe e occupancy sensors are cited, they shalt have the features listed a cit I ed they shall have th Where trautomatic i n Section 1513.6.2; 1513.1 Local Control enclosed by walls orcellt g- height parti Accessibility: space. partitions. be lighting lighting ghting controlls,whe e The whether one or more. be capable of r eadily accessible, at the point of entry/exit xit to personnel be occupying or using the space. EXCEPTIONS: The following lighting controls may be c entralized in remote locations: 1. Lighting conttrols for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be Installed provided the Individual switches retain their capability to function Independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing p rocess areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft . 1513.3 Daylight Zone Control: All daylighted zones, as defined In Chapter 2, both under overhead glazing and adjacent to vertical glazing. shall be provided with individual which control the lights independent of general area controls. ea ght ng. allowed o be controlled by a single controlling ng dv glazing are e provided that they do not Include zones facing more than two Da zo under overhead glazing more than south, west). from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or fixtures are h containing required to have aseparate switch l ft or general area lighting. 1513.4 Display. Exhibition and Specialty Lighting Controls: Ail display, exhibition or spedaitY lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight Is available rs. Lighting not es designated is not for dusk-to-dawn to-dawn o ti n shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shatl be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during toss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Oft Controls, interior. Buildings greater than 5.000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied t ours. Within these buildings, all oBce areas less than 300 ft enclosed by waits or ceiling- . height partitions. and all meeting and conference rooms, and all school classrooms. shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces. automatic controls may be on occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPT ONS 1 f Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated In a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. SvdtchIng for Industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas In which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1613.6.1 Occupancy Sensors: Occupancy sensors shalt be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. tight fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space Is occupied. EXCEPTION: Occupancy sensors in stairwells are fig hwed�ided th controlighting i i the high light position. light) provided Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and turns incorporate ff all loads fort holiday at least 24 t hours and then resumes normally scheduled operations. Automatic time switches shall also have program back-up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power Is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. Is readily accessible: b. is located so that a person using the device can see the tights or the areas controlled by the switch. or so that the area being illuminated Is annunciated; c. is manually operated; d. tlllow5 the lighting to remain on for no more than 2 hours when an over -ride Is Initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing sensors, or o me switches, the lighting occupancy g controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tasted plans and ensure they operate in accordance with approved A complete report of test procedures and notes shal require prepared commissioning in accordance Drawing ce with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 6 Watts or less per g Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is Integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1640 — TRANSFORMERS The minimum efficiency of a tow voltage dry type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified In Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers' Manufacturers Associat n ( National 2002) � Association I ec� anicaI$Ufl mart'„ 2004 Washington Slats Nonrssldencet Energy Code Co np4onCe Forms 2004 Washington State Nonresidential Energy Code Compliance Form Project Info Project Address Dross Barn 17250 Southcontor Parkway, Suite 112 Tukwila, We. Applicant Name: Robert H. Harris Jr., Sanderson Engineer's Inc. Applicant Address: 8325 Lenexa Dr Saito 100 Lenexa, gs 66214 Applicant Phone: (913)307 - 5300 Date 7/13/2007 For Building Dept. Use Project Description Briefly describe mechanical system type and features. 0 Includes Plans Packaged Trane RTU'S with economizers. Refer to drawing M1.1 for Equipment schedules. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option Di Simple System O Complex System o Systems Analysts (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information Is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Blum Total CFM OSA CFM or Econo? SEER or EER IPLV Location Heating Equipment Schedule Equip. ID Brand Name' Model No . Capacity Btulh Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency Fan Equipment Schedule Equip. ID Brand Name Model No . CFM SP' HPIBHP' Flow Control Location of Service 'if available. 7 As tested according to Table 14-1A through 14 -10. 3 If required. 3 COP, HSPF Combustion Efficiency, or AFUE, as applicable. 6 Flow control types: variable air volume(VAV), constant volume (CV). or variable speed(VS). System Description See Section 1421 for full description of Simple System qualifications. 2004 Washington State Nonresidential Enemy Code Compliance Form Mechanical Summary ( back }• MECH-SUM System Type Heating Only Yes — Yest. If Heating/Cooling it Constant vol? p Air cooled? Packaged sye? 0 <20,000 Btuh? or Cooling Only: 0 Sprit system? If Heating Only: 0 <5000 dm? 0 <70% outside air? Reference LSection 1421 Heating /Cooling or Cooling Only Yes Yes ( Reference ' Section 1423 Yes Economizer Included? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ingle Package Unit? Econo nduded? Air Cooled, Constant Vol? <70% OSA IC <20,000 tuh? otal Ca . economize <240,000 Btuh or 10%? plit Syste •84,000 Btuh? � or Adjacent to • utdoor Use Complex Systems (section 1430) I <54.000 tuh? Complex Systems I Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans Checklist yes yes .5. yes yea you yes .5. yea yea you • 0 1412 1412.1 1412.2 1412.3 1412.4 1412.4.1 1412.4.2 1412.5 1412.6 1412.7 1422 1423 1416 1416.182 1416.3 Temperature zones Deadband control Humidly control Automatic setback Dampers Optimum Start Heat pump control Combustion htg. Balancing Thermostat Interlock Economizers Mechanical Summary Form T T • 1 ip - I • f-Tigif7711 •4115[1.11) ECH-CHK yes . a . .5. yea . a . yes yes you 1413 Air economizers I 1413.1 Air Econo Operation Indicate 100% capablity on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate cig load & water sconce & cig tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1414.1 Duct sealing Indicate sealing necessary 1414.2 Duct insulation Indicate R.value of Insulation on duct 1415.1 Indicate locations on plans Indicate 5 degree deadband minimum indicate humldlstat Indicate thermostat with night setback and 7 dill, day types Indicate damper location and auto. controls & max. leakage Indicate optimum start controls Indicate microprocessor on thermostat schedule Indicate modulating or staged control indicate balancing features on plans Indicate thermostat Interlock on plans Equipment schedule Piping Insulation Indicate R-value of insulation on piping Completion Requ rements Drawings & Manuals Indicate requirement for record drawings and operation does. Air Balancing Indicate air system balance requirements M1.1 141.1 MI.. 1 141.1 P1.1 yes .5. 1416.3.3 Hydronic Balancing Indicate hydronle system balance requirements 1416.4 Commissioning Indicate requirements for commissioning and pre5m. Report 1424 Separate air sys. Indicate separate systems on plans plated and attached. Equipment schedule with types. 1MM/output efficiency, dm, hp. economizer 141.1 / 51 .1 M1. 1 541 . 1 M1.1 141.1 141.1 .5. you yes . a . . a . 'a. 1440 1441 1442 1443 1452 1452 1453 1454 2004 Washington State Nonresidential Energy Code Compliance Form . • Service water Mg. Elec. water heater Shut-off controls Pipe Insulation Heat Pump COP Heater Efficiency Pool heater controls Pool covers Indicate R-10 insulation under tank Indicate automatic shut-off Indicate R.value of Insulation on piping ndlcate minimum COP of 4.0 ndlcate pool heater efficiency Indicate switch and 65 degree control Indicate vapor retardant cover . a. 1454 Pools 80+ degrees Indicate R-12 pool cover It "no" is clicied for any question, provide explanation: 51.1 51.1 September 12, 2007 Tukwila Building Division Attention Allen Johannessen Re: Dress Barn — Permit #D07 -290 Dear Mr. Johannessen, Per your request and our telephone conversation yesterday please be advised our space for the above referenced project meets the 2006 Energy Codes and our compliance forms meet the 2006 energy codes. Additionally I give authorization to Mr. Allen Johannessen to red mark the plans. Thanking you in advance for you help, if you should need any additional information please don't hesitate to contact me. Sincerely„ incent Caruso Project Manager /Designer CORRECTION D07'- zo 30 Dunn+gan Drive Suffern, NY 10901 (845)369 -4500 tax: (845)369 -4379 www,dressbarn.com :4FrERIFD SEP 12 2007 l=rM , CcNIE:f-, September 6, 2007 Roxanne Bruno 1625 W 8510 S West Jordan UT 84088 Dear Ms. Bruno, City of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number D07 -290 Dress Barn —17250 Southcenter Py f Steven M. Mullet, Mayor This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I'have included comments from the Building and Planning Departments. At this time the Fire and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Planning Department: Moira Carr Bradshaw at 206 461 -3651 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision. Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3760. Sincerely arshall hnician encl File No. D07 -290 P:\Permit Center\Correction Letters V007007 -290 Conection Ltr #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: September 4, 2007 Project Name: Dress Barn Permit #: D07 -290 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Two sheets are missing from the plan set, # 11 & 12. Please provide all drawing sheets. 2. Provide a reflective ceiling plan. The ceiling plan shall identify emergency pathway lighting, emergency lighting and identify lit exit signs to include directional exit signs. The two sheets missing 11 & 12 may show these requirements. (IBC 1006) 3. In addition to item 2), identify type of ceiling or if ceiling is intended to be full height of buildings shell. Suspended ceiling shall require suspended ceiling details and meet ASCE Standards 9.6.2.6.2.2. 4. Revise accessible bathroom plan to show an 18" vertical grab bar. (2003 ANSI 604.5.1) 5. Please provide a complete set of drawings with all revised pages together. Pages 13 and 14 are not necessary. The energy code compliance for may be submitted together in 8'/2 x 11 letter size sheets. Provide two copies of the revised sets. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. To: Permit Division Subject: D07 -290 Correction For your information: Interdepartmental Memorandum From: Moira Carr Bradshaw, Senior Planner Department of Community Development Planning Division 206 431 3651; mbradshaw @ci.tukwila.wa.us Please revise the relevant dimensions on Sheets 2 and 3 to be in accordance with Landlord north south dimensions between south window wall and front of display wall. Please verify dimension with Koch plans, which is approximately 4.5 feet as opposed to 3 feet. Businesses are allowed two signs that are visible from the right of way /street. Sign permit applications are available on the City's web page: http://www.ci.tukwila.wa.us/dcd/apps/PermSign-12-06.pdf \ \Tuk2 \vo13 HOME\MOIRA\penneys \d07290.doc I- August 8, 2007 . Roxanne Bruno 1625 W 8510 S West Jordan UT 84088 Nov Dear Ms. Bruno, City of Tukwila RE: Letter of Incomplete Application # 1 Development Permit Application D07 -290 Dress Barn — 17250 Southcenter Py Department of Community Development Steve Lancaster, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 6, 2007 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following departments needs to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning the attached comments. Steven M. Mullet, Mayor Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, arshall it\Tekhnician Enclosures File: D07 -290 P:\Permit Center\Incomplete Letters\2007\D07 -290 Incomplete Ltr #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 i Determination of Completeness Memo Date: August 7, 2007 Project Name: Dress Barn Permit #: D07 -290 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable, Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Revise code notes to meet current 2006 Building codes. 2. Complete a non residence Washington State Energy code lighting summary sheet. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -290 PROJECT NAME: DRESS BARN SITE ADDRESS: 17250 SOUTHCENTER PY _ Original Plan Submittal X Response to Correction Letter # 1 DATE: 09 -12 -07 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS t Bui ng I Sion Public Works Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 Fire Prevention Structural Incomplete Structural Review Required ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) 41 4-* P annl g Division Permit Coordinator DUE DATE: 09 -18 -07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 10 -16 -07 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions d Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D07 -290 DATE: 08 -23 -07 PROJECT NAME: DRESS BARN SITE ADDRESS: 17250 SOUTHCENTER PY Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 HERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Fire Prevention Structural Review Required Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -28 -07 Incomplete Planning Division Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 09-25-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only �j, �{ , CORRECTION LETTER MAILED: V"lll/�1(n Departments issued corrections: Bldg Fire ❑ PIng§t PW ❑ Staff Initials: . N" Complete ❑ ACTIVITY NUMBER: D07 -290 DATE: 08 -06 -07 PROJECT NAME: DRESS BARN SITE ADDRESS: 17250 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPAR MENTS: u ding Di n .A,�,� c5' Public Works Comments: Documents/routing slip.doc 2 -28 -02 �-' PERMIT COORD COPY '— PLAN REVIEW /ROUTING SLIP • Zi DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Permit Center Use Only INCOMPLETE LETTER MAILED: 1-6-1 APPROVALS OR CORRECTIONS: Structural Incomplete ❑ Departments determined incomplete: Bldg TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: 5F0 ow e- 0 - °1 Fire Prevention Planning Division ❑ Permit Coordinator n LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 08-07-07 No further Review Required DATE: DUE DATE: 09-04-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Not Applicable ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 09-06-'07 10: Z4 FiltRI- publicworKs /den City of Tukwila Department of Community Development 6300 Southeenter Boulevard, Suite #100 ill Washington 98188 Phone: 206 -431 -3670 Pax: 206- 431 -3665 Web site: h : //s vcttukwilo wavy "ZUVEintibb T - "ldS rOd5f i r - 850 Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fan etc. Date: - Ce-07 Plan Check/Permit Number: D07 -290 ❑ Response to incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name; Dress Barn Project Address: 17250 Southeenter Py Contact Person: VACe,n C - L)Sc Phone Number Summary y of Revision: &O DIVlslon CeVieto — C - Lve aeirlo gleel- It 412 C• - • Ce : • �- . men re a 4o hee-41 9 a Jb0 4 ►that.\\ f■ler1 Ov►cior Sopafc g eeCthrt• C omtt'C¢. t* ii - Cep d 4 \ 'S. LeimJIAA 4-o 140,..A. 41-.S'oocvis VaY Le.4)10 c) 4 byleler Separc Peer" C' e„A - Se +s 8Y x 11 a. come) Dtmensiot\ l' 'i = oIN Ssioce 'ce M . CeC' -k gkbef 'L ()CI SheetNumber(c): LatC100. bcatr (.$)G..■k trnedter sefl t 4e- ee - 0NA. "Cloud" or highlight all areas of revision including date of r Received at the City of Tukwila Permit Center by: Entered in ' emits Plus on 9 - -07 4pphesuais'to ms- oppIies ons on lizclravisian.utumcml Crested_ 2 -13 -2004 Revisal: SEP 12 2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:• / /www.ci.tukwila.wa.us ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 17250 Southcenter Py Contact Person: V In c e4/ Caroso "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: Entered in Permits Plus on (J7 \applications\foims- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 8- 20 -01 Plan Check/Permit Number: D07 -290 Phone Number: (8'4 ! 9 - ` 1 658, Summary of Revision: I - ReVISecL td(QS Oar. be Qovnr) on S' boe+ . reVtilon has bee„ elowkei. 2. 4 g1,„�ICx, Sae ene cocks Ce,,,, be ,nd on S1lee -VS 1 3 ly Sheet Number(s): PERMIT CENTER revision Steven M. Mullet, Mayor HECE1VEU L I License Information License ARGONBI934N2 Licensee Name ARGONAUT BUILDERS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602490806 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 50 BIRCH AVE Address 2 City LITTLE SILVER County OUT OF STATE State NJ Zip 07739 Phone 7329330099 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/22/2007 Expiration Date 8/22/2009 Suspend Date Separation Date Parent Company ARGONAUT INC Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date CT CORP SYSTEMS AGENT 08/22/2007 KARAGIANAKIS, TOM PRESIDENT 08/22/2007 DAVIS, MICHELE VICE PRESIDENT 08/22/2007 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Company Bond Account Effective Expiration Cancel Impaired Bond Received https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ARGONBI934N2 09/26/2007 SCOPE OF WORK ANY WORK DENOTED AS BY LANDLORD' SHALL BE FILED UNDER SEPARATE PERMIT BY LANDLORD ANrJ SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PROOR TO DRESS BARN'S CONTRACTOR COMMENCING WORK. GENERAL REQUIREMENTS DEMOLITION PERMITS, FEES, INSURANCE TRASH REMOVAL CERTIFICATE OF OCCUPANCY PROFESSIONAL CLEANING STOREFRONT STOREFRONT BARRICADE STOREFRONT GLASS GLAZING E FRAME STOREFRONT GRILLE STOREFRONT FASCIA CONCRETE /STEEL CONCRETE SLAB CONCRETE SEALER MISC. STEEL MECHANICAL SPRINKLER SYSTEM SPRINKLER MODIFICATIONS FIRE PAMPERS SMOKE DUCT DETECTORS FiRE EXTINGUISHER E TAGS /SIGNS GAS SERVICE TO PREMISES GAS METER HVAC UNiTS: SIZED AT I TON /300 S.F ELECTRIC DUCT HEATER HVAC DUCTWORK DIFFUSERS HVAC PADS / CURBS HVAC CIRCUITS THERMOSTATS AND CONTROL WIRE THEr'MOSTAT RELOCATION AIR BALANCE REPORT PLUMBING / TOILET ROOM WATER SERVICE TO PREMISES UNDER SLAB ROUGH -IN TOILET ROOM FIXTURES TOILET ROOM ACCESSORIES WATER FOUNTAIN SERVICE SiNK ELECTRIC HOT WATER HEATER WATER METER COLD E HOT WATER SUPPLY LINES TOILET ROOM FAN E LIGHT TOILET ROOM PARTITIONS TOILET ROOM CEILING TOILET ROOM V.C.T. TILE E BASE CALL FOR AID BELL CARPENTRY DEMISING WALL STOCK ROOM WALL WITH OPENING INTERIOR PARTITIONS WALL STANDARDS STOCK ROOM SHELVING MILLWORK (FIT ROOM /CASHWRAP /SALES AREA) DOORS STOREFRONT ENTRANCE DOORS REAR DOOR WITH HARDWARE STOCK ROOM POOR WITH HARDWARE FITTING ROOM DOORS, FRAME IN: HARDWARE TOILET ROOM DOORS WITH HARDWARE FINISHES PAINTING CARPET CERAMIC TILE FLOORING ENTRANCE MAT V.CT. FLOOR TILE AND BASE (STOCK ROOM) VINYL SASE (SALES B FITTING ROOM AREA) MIRRORS ACOUSTICAL CEILING ELECTRICAL ELECTRICAL SERVICE TO PREMISES ELECTRICAL METER ELECTRICAL DISTRIBUTION PANELS LIGHTSTAT AUTO LIGI- TNG CONTROL SYSTEM DISCONNECTS 2 X 4 LAY -IN FLUORESCENT FIXTURES FO32 /730 LAMP 2 X 2 LAY -IN FLUORESCENT FIXTURES F017/730 LAMP NIGHT LIGHT FIXTURES STRIP FLUORESCENT FIXTURES EXIT SIGNS PER CODE ADDITIONAL EXIT SIGNS EMERGENCY BATTERY FIXTURES PER CODE ADDITIONAL EMERGENCY SATTERT FIXTURES TRACK LIGHTING BOW G.E. CAPSYLITE HALOGEN LAMPS DEDICATED OUTLETS WALL OUTLETS LIGHT SENSORS TIMER FOR E-1 E 13 FIXTURES CIRCUITS SPEAKERS, TRANSFORMERS & WIRING CONTACTORS LIGHT SWITCHES DOOR SELL E BUZZER SIGNAGE EXTERIOR SIGNS EXTERIOR SIGN CIRCUITS EXTERIOR SIGN TIMER INTERIOR GRAPHIC PACKAGE STOREFRONT DECAL PACKAGE PATCH, REPAIR E PAINT FASCIA FINAL CONNECTION TO SIGNS FURNISHED INSTALLED DI- NA LLC DB DBC LLC DB DBC x NA LLC DB DBC LLC DB .DBC x x x x x NA LLC - DB DBC. LLC DB DBC NA LLC DB DBC LLC DB DBC x x x x x x x x x X X x NA LLC DB DBC LLC DB DBC x x x x x x x x x x x X x x x Nq O N E Es 5 x x x x x x x x x x x x x x x x X x x x x x x x x x x x x x x NA LLC DB DBC LLC DB. DBC x x x x x x x x x x NA LLC DB DBC LLC DB DBC x x x NA LLC DB DBC LLC DB DBC x NA LLC , DB DBC LLC DB DBC x x X X x x x x x x x x X X x x X x x X x x X x X x x x x x X x x x x X X x x X X X X X X X X X X X X x X X fl X X x x X Q Ir F 'I) T1 V X X x x x X X X X X x x NA LLC DB DBC LLC DB DBC INDEX OF DOCUMENTS ARCHITECTURAL COVER SI FEET 2 - FLOC FL4� a LAYOUT 3 - BLOW UP FLAN WALL SECT10 5 - FIXTURE PLAN 6 = EL.VA-10NS 7 STCREFRO '-T EL VAT1O 6 - FLOOR COVERING FLA 9 -- SIGNAGE PLAN TRAV7L PAT ELECTRICAL LIGHTING PLAN 12 - PCWE PLAN A gFEEZEZEZEZEZEM c SYM = OLS e - G - AREA DETAILED NEW PARTITION 20 GAUGE 3-5/8' SHEET METAL STUDS 16" O.C. WiTH 5/8" SHEET ROCK ON BOTH SiDES (SEE DETAIL 1 ON A -1A) (BY TENANT G.C.) EXISTING PARTITION TO REMAIN FOR DEMISING WALLS AND FiRE RATED WALLS SEE DETAIL 4 DRAWING A1.1. FOR INTERIOR PARTITIONS SEE DETAIL 1 DRAWING A1.1. EXISTING CONCRETE BLOCK WALL NEW PARTITION 20 GAUGE 3 - 5/8" SHEET METAL STUDS 16" O.C. TO BE FiRE RATED WiTH 5/8" SHEET ROCK ON BOTH SIDES. TIGHT TO DECK ABOVE AND TO BE CAULKED AT THE FLOOR AND DECK (BY TENANT G.C4 EXISTING BASE BUILDING EXTERIOR WALL BUILT OUT WiTH 5/8' TYPE 'X' GYPSUM BOARD ON 2 -1/2' MIN. METAL STUDS WITH A MiNiMUM OF R11 INSULATION TO REMAIN. (SEE DETAIL 3 DRAWING MA) PREFABRICATED MILLWORK (INSTALLED BY TENANT G.C.) C EXISTING PARTITION TO BE REMOVED ELEVATION NUMBER LETTER REFERENCE DRAWING NO. DOOR SCHEDULE SYMBOL CONSTRUCTION CLASSIFICATION: IV SPRINKLERED BUILDING USE GROUP: M (MERCANTILE) OCCUPANT LOAD: 203 PEOPLE (630 S.F. STOCKROOM = 2 P 6,049 S.F. SALES AREA = 201 P) S DETAILS S FiRE EXTINGUISHER 40 -LB, MULTIPURPOSE E X DRY - CHEMICAL (CLASS A, B, C) TO BE MOUNTED 3' -O" ABOVE FINISHED FLOOR WHERE SHOWN OR DIRECTED BY LOCAL FiRE MARSHALL E ANALYSIS BUILDING CODE: 2006 IBC PLUMBING CODE: 2006 UPC MECHANICAL CODE: 2006 iMC ELECTRICAL CODE: WA STATE LABOR AND INDUSTRIES ENERGY CODE: 2006 WA STATE ENERGY CODE ACCESSIBILITY CODE: 2006 IBC FiRE/ LIFE SAFETY CODE: 2006 IFC SIGNAGE R No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal I and may include additional plan review fees. 1. ALL TRADE ANP SUM - RAPES SHALL SE REGISTERED WITH THE CITY, COUNTY, STATE AND AUTHORITIES AS REQUIRED. 2. THE TENANT G.C. SHALL INCLUDE THE COST OF ALL PERMITS AND LICENSES IN THE CONTRACT, INCLUDING BUILDING PERMIT. THE SUBCONTRACTORS SHALL INCLUDE ALL PERMIT AND LICENSE COSTS AS REQUIRED BY THEIR TRADE IN THEIR PROPOSALS TO THE TENANT SG PERMITS AND FEES TO INCLUDE CONNECTING OF ALL EQUIPMENT, FIXTURES, SERVICES AND UTILITIES AS REQUIRED. a ALL TRADES SHALL CONFORM WITH ALL APPLICABLE FEDERAL, STATE, MUNICIPAL, PROJECT MALL DEVELOPER AND /OR BUIL-DING OWNER AND O.S.H.A. CODES, RULES AND REGULATIONS. 4. THE 'GENERAL CONDITIONS' OF THE CONTRACT FOR CONSTRUCTION DOCUMENT A-107 ISSUED BY THE AMERICAN INSTITUTE OF ARCHITECTS 4987 EDITION RELATES TO THE WORK OF THIS PROJECT AND IS HERESY MADE A PART OF THESE DRAWNGS AS THOUGH FULLY CONTAINED IN THESE DRAWINGS. 5. THE "TENANTS" GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE NECESSARY NUMBER OF COPES OF DOCUMENT A TO ACQUAINT HIMSELF WITH THE ARTICLES CONTAINED THEREIN AND TO NOTIFY AND APPRISE ALL SUBCONTRACTORS, SUPPLIERS AND ANY OTHER PARTIES TO THE CONTRACT OR INDIVIDUALS OR AGENCIES ENGAGED ON THE WORK AS TO ITS CONTENTS. 6. NO CONTRACTUAL ADJUSTMENT SHALL BE DUE OR COME IN DEMAND AS A RFSILT OF FAILURE ON THE PART OF THE CONTRACTOR TO FULLY ACQUAINT MMSELF AND ALL OTHER PARTIES TO THE CONTRACT WITH THE CONDITIONS OF DOCUMENT 5-107. 7. THE COSTS SUBMITTED BY THE TENANT G.C. ARE UNDERSTOOD IN EVERY CASE TO INCLUDE ALL GOVERNMENT AND MUNICIPAL TAXES AND FEES OF EVERY KIND, AND THE OWNERS SHALL NOT BE CALLED UPON TO MAKE ANY PAYMENTS ON SUCH TAXES IN ADDITION TO THE CONTRACT AMOUNT. a THE SPECIFICATIONS ARE COMPILED NOT ONLY TO ESTABLISH A STANDARD, BUT TO INSURE THE TENANT G.C. MAINTAINS A QUALITY IN THE PERFORMANCE AND FINISH OF THE WORK RECOMMENDED AND ACCEPTED BY DRESS BARN. THE TENANT SG SHALL BE RESPONSIBLE FOR FULLY ACQUAINTING HIMSELF WITH THE CONTENT AND SCOPE OF THESE SPECIFICATIONS, AND SPECIAL ATTENTION SHOULD BE GIVEN TO THE SPECIFICATIONS THROUGHOUT THE SPAN OF THIS CONTRACT BY THE TENANTG.C.'S SUPERVISOR AND SUBCONTRACTORS, AS THE STANDARDS ESTABLISHED HEREIN SHALL BE APPLIED WITH EMPHASIS TO ALL WORK WORK DECLARED UNACCEPTABLE BY PRESS BARN'S AGENT SHALL BE CORRECTED IN A MANNER AND DEGREE OF QUALITY AS ACCEPTED BY DRESS BARN. 9. THE TFJUNT G.C. AND SUBTRADES SHALL VISIT AMP FAMILIARIZE THEMSELVES WITH ALL EXISTING CONDITIONS AT THE JOB SITE. IN THE EVENT OF ANY DISCREPANCIES BETWEEN THE ACTUAL FIELD CONDITIONS AND THOSE INDICATED ON PRESS BARN DRAWINGS THE BID PROPOSAL SHALL INCLUDE THESE ADDITIONAL COST ESTIMATES. UPON ACCEPTANCE OF BID PROPOSAL BY PRESS BARN, NO ADDITIONAL COMPENSATION SHALL BE GIVEN FOR ANY DISCREPANCIES NOT INCLUDED IN THE ORIGINAL GO PROPOSAL 10. SPECIAL ATTENTION SHOULD BE GIVEN TO THE DIMENSIONS INDICATED AS 'HOLEY DIMENSIONS. THE TENANTG.G. AND SUBTRADES SHALL S VERIFY ALL EXISTING DIMENSIONS AND LOCATION S OF T118 -INS. THE TENANT G.C. SHALL BE LIABLE FOR ALL COSTS INCURRED BY HIMSELF OR OTHERS BY FAILING TO MAINTAIN THE DIMENSIONS ON THE DRAWINGS OR CONTACTING PRE SS BARN N THE CASE OF DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DIMENSIONS ON THE DRAWINGS. 44. THE TENANT &C. SHALL VERIFY THE RESPONSIBILITIES OF THE PROJECT LANDLORD IN RESPECT TO THE EXTENT AND TYPE OF WORK REQUIRED FOR THE STORE. THE TENANT GO SHALL NOTIFY DRESS BARN OF ANY DISCREPANCIES BETWEEN THE PROJECT LANDLORD'S RESPONSIBILITIES AMO THOSE INDICATED ON THE DRAWINGS. THE TENANT G.C. SHALL ALSO COORDINATE THE INSTALLATION OF THE LANDLORD'S STORE WORK WITH THE PROJECT RE AND ALSO PROVIDE REQUIRED COMPLETION PATES FOR ITEMS IN THE LANDLORD'S SCOPE OF WORK TO THE LANDLORD'S CONTRACTOR. 12 DEMOLITION CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING FIELD CONDITIONS SO AS TO FAMILIARIZE HIMSELF WITH THE DEMOLITION AND /OR REMOVAL WORK WHICH MAY BE REQUIRED TO PRODUCE THE END RESULTS INTENDED IN THE CONTRACT DOCUMENTS. THE RENOVATION WORK DESCRIBED IN THE CONTRACT DOCUMENTS ANTICIPATES THE DEMOLITION OF EXISTING CONSTRUCTION IN PART OR N ITS ENTIRETY, AND THE REMOVAL, RELOCATION AND REPOWERNG OF CERTAIN CONSTRUCTION MATERIALS AND EQUIPMENT. IT IS THE INTENT THAT EACH PORTION OF THE DEMOLITION AND REMODELING WORK BE DONE BY SPECIFIC TRADE INVOLVED IN THE INITIAL INSTALLATION, THAT IS CARPENTRY WORK BY THE CARPENTRY TRADE, MECHANICAL AND ELECTRICAL WORK DONE BY THE MECHANICAL AND ELECTRICAL TRADES, RESPECTIVELY AND SO ON. THEREFORE, EACH CONTRACTOR AND SUBCONTRACTOR SHALL THOROUGHLY EXAMINE THE PROPOSED WORK AND MAKE ALLOWANCES IN HIS PROPOSAL FOR COST OF ALL DEMOLITION AND /OR REMOVAL WHICH MAY BE REQUIRED TO PRODUCE THE END RESULTS INTENDED BY THE CONTRACT DOCUMENTS. REMOVE ALL DEBRIS DAILY TO DESIGNATED AREA G SHORING AND SUPPORTS AS REQUIRED PROVIDE TEMPORARY BRAGIM H FOR EXISTING STRUCTURAL SYSTEMS TO PREVENT DAMAGE DURING CONSTRUCTION. THE ELECTRICAL CONTRACTOR SHALL REMOVE ANP /OR RELOCATE ALL EXISTING ELECTRICAL DEVISES, CONDUIT, AND WIRING WORK AS CALLED OUT ON THE DRAWINGS AND AS NECESSARY WHETHER SUCH ITEMS ARE INDICATED ON DRAWINGS OR NOT, IN ORDER TO ACCOMPLISH THE INSTALLATION OF THE SPECIFIED NEW WORK - EQUIPMENT. MATERIAL AND DEVISES REMOVED SHALL BECOME THE PROPERTY OF CONTRACTOR IF APPROVED BY DRESS BARN). SUCH ITEMS MAY BE RFLISED IF SPECIFICALLY DESIGNATED ON THE DRAWINGS. CONDUIT, WIRE AND OUTLET BOXES REMOVED SHALL BE SCRAPPED BY THE ELECTRICAL CONTRACTOR WHERE WALLS AND CEILINGS ARE TO BE REMOVED AS SHOWN ON THE DRAWINGS. THE CONDUIT IS TO BE CUT OFF BY THE ELECTRICAL CONTRACTOR SO THAT THE ABANDONED CONDUIT IN THESE WALLS AND CEILINGS MAY BE REMOVED FROM THE WALLS AND CEILINGS BY THE DEMOLITION CONTRACTOR. N TES ANY WORK DENOTED AS BY LANDLORD" SHALL BE FILED UNDER SEPARATE PERMIT BY LANDLORD AND SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PRiOR TO DRESS BARN'S CONTRACTOR COMMENCING WORK. THE SiGNAGE CONTRACTOR iS RESPONSIBLE FOR OBTAINING THE SiGNAGE PERMIT AND SHALL NOT FABRICATE SIGNAGE UNTIL SHOP DRAWINGS ARE APPROVED BY BOTH DRESS BARN AND THE LANDLORD AS WELL AS ALL LOCAL MUNICIPAL AUTHORITIES. LANDLORD TO PROVIDE H.V.A.C. AS FOLLOWS: 100% NEW H.V.A.C. UNiTS FOR 100% OF LEASED SPACE WITH CONTROLS, NIGHT SET BACK THERMOSTATS (LIGHTSTAT MODEL #TME -AVU), AND ECONOMIZERS. DUCTING MUST BE INSULATED AND UNIT(S) MUST HAVE A DIRECT DUCT RETURN SYSTEM. 100% OF PREMISES TO BE DUCTED TO ACCOMMODATE TENANT'S ARCHITECTURAL LAYOUT. MINIMUM REQUIREMENTS OF 4 TON OF AiR CONDITIONING FOR EVERY 300 SQUARE FEET AND A MINIMUM TEMPERATURE OF 70 DEGREES TO BE MAINTAINED THROUGHOUT THE ENTIRE PREMISES DURING THE HEATING SEASON WHEN THERE 1S 0 DEGREES F OUTSIDE WITH 15 MPH WIND. NO ONE DIFFUSER TO BE SUPPLYING MORE THAN 500 CFM. LANDLORD WiLL PROVIDE DUCT HEATERS WiTH INDIVIDUAL T STAT FOR STOCK ROOM AND REAR AREA FITTING ROOMS. LANDLORD WILL PROVIDE BALANCING REPORT TO DRESS BARN AT TiME OF POSSESSION. LANDLORD /LANDLORD CONTRACTOR SHALL REFER TO LEASE EXHIBIT "DRESS BARN WHITE BOX SPECS" FOR DETAILED DESCRIPTION OF MECHANICAL REQUIREMENTS WHiCH INCLUDE HVAC, ELECTRICAL, PLUMBING AND FIRE PROTECTION. Tenant Im ALL DEAD END CONDUIT RUNS SHALL BE PLUGGED AT THE REMAINING LINE OUTLET BOXES OR AT THE PANELS. THE TENANT G.C. SHALL REMOVE ALL EXISTING FLOOR COVERINGS FROM THE SPACE, REPAIR PATCH, LEVEL, SMOOTH AND REPAIR EXISTING SLAB AS REQUIRED FOR INSTALLATION OF NEW FLOOR COVERINGS. ALL CEILING CONSTRUCTION INCLUDING (BUT NOT LIMITED TO) DROPS, BULKHEADS, LIGHTING, DIFFUSERS, ETC, SHALL BE REMOVED UNLESS SPECIFICALLY CALLED OUT TO REMAIN ON DEMOLITION PLAN. THE TENANT G.G SHALL INCLUDE IN THIS WORK THE ERECTION OF A BARRICADE, IP NONE IS PROVIDED BY THE LANDLORD. HE SHAW-. CONSTRUCT A BARRICADE 3'-0' BEYOND THE LEASE LINE, SECURE IN A NEAT AND STABLE FASHION WITHOUT ANCHORING DIRECTLY TO MALL FLOOR. INSTALL A NYLON REINFORCED PLASTIC DUST BARRIER AT TOP AND SIDES. THE TENANT G.C. SHALL INCLUDE IN HIS COST THE ERECTION AND REMOVAL OF SAME NOTE IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO LAYOUT THE PROPER LIGHTING CONTACTOR QUANTITY WITH THE AMOUNT OF LIGHTING INDICATED PER JOB. 13. THE TENANT C.C. AND /OR HIS SUBCONTRACTOR SHALL MAKE ALL REPAIRS TO THE PREMISES NECESSITATED BY THE REMOVAL OF THE IMPROVEMENTS MADE BY PREVIOUS OCCUPANTS SUCH WORK SHALL INCLUDE BUT NOT BE UNITED TO CONCRETE, SLAB, MECHANICAL AND ELECTRICAL EQUIPMENT, TELEPHONE EQUIPMENT, PARTY WALLS AND INTERIOR FINISHES. 14. THE TENANT 43.C. SHALL PROVIDE SUCH EXTENSIONS, DEVISES, HOOKUPS AND METERING AS REQUIRED FOR TEMPORARY WATER, POWER, LIGHTING, HEAT OR AS REQUIRED TO CARRY OUT THE WORK ALL TEMPORARY UTILITIES AT THE TENANT CG'S EXPENSE 15. THE TENANT 0.C. SHALL SUPERVISE AND DIRECT THE WORK USING HIS BEST SKILLS AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL FABRICATION, SHIPMENT, DELIVERY, AND INSTALLATION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. A WHEN DRESS BARN MATERIAL IS RECEIVED AT THE JOB SITE, THE SUPERINTENDENT IS TO INVENTORY AGAINST DRESS EARN VENDORS LIST AND DRESS BARNS DRAWINGS AND SHALL NOTIFY DRESS BARN'S PROJECT MANAGER OR DRESS BARN'S REPRESENTATIVE IMMEDIATELY. IF NOTIFICATION IS NOT FORTHCOMING, REPLACEMENT OF SHORTAGES OR DAMAGED MATERIALS SHALL BE BACK CHARGED TO THE TENANT G.C. B- THE SUPERINTENDENT WILL BE REQUIRED TO MAINTAIN A DAILY JOURNAL OF EVENTS WHICH SHALL INCLUDE: WORK PERFORMED, NUMBER OF WORKERS OF EACH TRADE ON JOB SITE, CONSTRUCTION CHANGES, Tel F PEON E CALLS, ETC JOURNAL TO BE PROVIDED TO DRESS BARN AT COMPLETION OF CONSTRUCTION, IF REQUIRED. G THE TENANT G.C. SHALL BE RESPONSIBLE FOR COORDINATING WITH DRESS EARNS CONSTRUCTION PROJECT MANAGER AT THEIR MOST AVAILABLE DATE WHEN CONSTRUCTION IS COMPLETE. FOR VISITING THE JOB SITE AND DOING THE PUNCH LIST. 46. THE TENA G.C. S AL- EMPLOY A COMPETENT SUPERINTENDENT AND H NECESSARY ASSISTANTS WHO SHALL BE IN ATTENDANCE OF THE PROJECT PREMISES DURING THE PROGRESS OF THE WORK THE REPRESENT SG AND ALL SUPERINTENDENT SHALL RE EN T THE TENANT COMMUNICATIONS GIVEN TO THE SUPERINTENDENT SHALL BE AS BINDING AS IF GIVEN TO THE TENANT G.C. 17, THE TENANT G.C. SHALL BE RESPONSIBLE TO DRFSq. BARN FOR ACTS AND OMISSIONS OF HIS EMPLOYEES, SUBCONTRACTOR S AN D THEIR AGENTS AND EMPLOYEES. AND OTHER PERSONS PERFORMING ANY OF THE WORK UNDER A CONTRACT WITH THE TENANT G.C. TENANT G .C. SHALL ALL 48. THE 5HA AT A TIM ES ENFORCE STRICT DISCIPLINE AND GOOD ORDER AMONG HIS EMPLOYEES AND SHALL NOT EMPLOY AN Y UN FIT PERSON OR ANY PERSON NOT SKII I F n IN THE TASK ASSIGNED. 19. THE TENANTG.C. AGREES THAT IN THE PERFORMANCE OF THE WORK CALLED FOR BY THE CONTRACT AND CONTRACT DRAWINGS HE WILL EMPLOY ONLY SUCH LABOR AS WILL NOT DELAY OR INTERFERE WITH THE SPEEDY AND LAWFUL PROGRESS OF THE PROJECT AND SHALL BE ACCEPTABLE TO AND WORK IN HARMONY WITH ALL OTHER WORKMEN EMPLOYED ON THE CONSTRUCTION SITE OR ANY OTHER BUILDING STRUCTURE OR OTHER IMPROVEMENT WHETHER PUBLIC OR PRIVATE WHICH THE TENANT G.C. MAY THEN BE ERECTING OR ALTERING. 20. ALL SUBTRADES SHALL COORDINATE THEIR WORK WITH THE WORK OF OTHERS, OR WHICH EXISTING CONDITIONS OCCURRING ABOVE OR BELOW THE PREMISES AND SHALL MAKE CHANGES FROM TIME TO TIME AS REQUIRED TO ACCOMMODATE SUCH WORK OR CONDITIONS. ALL CHANGES THAT SHALL EFFECT THE FINAL APPEARANCE OF THE PROJECT SHALL BE APPROVED IN ADVANCE BY DRESS BARN 21. THE TENANTG.C.S OR. SUB-CONTRACTOR'S SIGNS MAY NOT BE DISPLAYED AND NO SIGNS OF ANY KIND MAY BE PLACED ON BARRICADES WITHOUT APPROVAL OF DRESS BARN 22 ALL TRADES SHALL CONFINE CONSTRUCTION WORK WITHIN THE PREMISES AS MUCH AS POSSIBLE AND SHALL WORK IN AN ORDERLY MANNER REMOVING TRASH AND DEBRIS FROM THE PROJECT ON A DAILY BASIS. AT NO TIME WILL PIPES, WIRES, BOARDS OR OTHER CONSTRUCTION MATERIAL. CROSS PUBLIC AREAS WHERE HARM COULD BE CAUSED TO THE PUBLIC. 23. THE PROJECT LANDLORDS ROOFING CONTRACTORS WILL, AT SUBTRADES' WRITTEN REQUEST AND COSTS, PROVIDE OPENINGS ANCHORING DEVICES, CURBS, FLASHING PATCHES, ETC. AS REQUIRED FOR EQUIPMENT. ALL SUBTRADES TO INCLUDE THE COST OF ALL SUCH WORK IN THEIR PROPOSALS. 24. PAINT CONTRACTOR SHALL STENCIL PAINT ALL ROOF UNITS, FANS, SWITCHES, ETC. WITH NAME AND NUMBER OF TENANT STORE AS SOON AS IT IS INSTAL I Fn IN A MANNER AND COLOR APPROVED BY THE LANDLORD AND /OR DRESS BARN. 25. CUTTING AND PATCHING OF ROOF DECK FOR ALL OPENINGS SHALL SE PERFORMED BY LANDLORD'S ROOFER AT SUBCONTRACTOR'S EXPENSE ME ODIN Permit No. Plan review approval is subject to errors and omissions. Approval c; cc: ,: 'ction documents does not authoriza the vioia'tic- c; c;,do cr or dirsnC.e. Receipt z J of ppr;.. ) c. - - cc':noA tiledged; Date: PROJECT MANAGER VINCENT CARUSO (845) 369 -4658 LANDLORD CONTACT LESITYA WiG (425) 957 -4774 City of Tukwila BUILDING DIVISION E NE CONTA€TS ALL QUESTIONS AND CORRESPONDENCE WiTH THE EXCEPTION OF CODE AND PLAN REVIEW ARE TO BE DIRECTED TO DRESS BARN AND NOT TO THE PROJECT ARCHITECT. AVP OF PLANNING S DESIGN JEFF ROSS (845) 369 -4740 DIRECTOR OF STORE PLANNING AND CONSTRUCTION JACK CAPPELLO (845) 369 -4725 H.V.A.C. SYSTEM BY LANDLORD ON SEPARATE PERMIT. SPRINKLER SYSTEM BY LANDLORD ON SEPARATE PERMIT. PLUMBING BY LANDLORD ON SEPARATE PERMIT. FIRE ALARM SYSTEM BY LANDLORD ON SEPARATE PERMIT. SEPARATE REQUi PERMIT FOR: anicai • Electrical � 01 Gas Piping City of Tukwila BUILDING DIVISION rove 25 BUILDING DOORS ARE NOT TO BE PROPPED OPEN BY CONSTRUCTION MEN AT ANY TIME. 27, THERE WILL BE NO STORAGE OF MATERIALS OR RUBBISH IN CORRIDORS OR OTHER T AREAS AT ANY TIME. IF DEBRIS IS FOUND IN THESE AREAS, IT WILL BE REMOVED AT THE EXPENSE OF THE CONTRACTOR RESPONSIBLE. 28. ALL SUBTRADES SHALL VERIFY REMOVAL OF DEERS AND GARBAGE GENERATED BY THEIR WORK TO RECEPTACLE PROVIDED BY THE TENANT GC. LOCATION TO BE DESIGNATED BY LANDLORD. 29. ALL SUBTRADES SHALL REMOVE EXCF MATERIALS AFTER WORK IS COMPLETED AND FLOOR TO SE BROOM CLEANED. 30. ALL MATERIALS USED IN CONSTRUCTION SHALL BE MEW AND OF FIRST CLASS QUALITY UNLESS OTHERWISE INDICATED. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER PATE OF THE OPENING OF THE STORE 34. THE TENANT G.C. SHALL PROVIDE MATERIALS AND EQUIPMENT NECESSARY TO COMPLY WITH LOCAL LANDLORD AND DRESS BARN REQUIREMENTS FOR NOISE, DUST AND POLLUTION CONTROL AND FOR PROTECTION OF EXISTING CONDITIONS AND FINISHES- 32 MATERIALS AND EQUIPMENT SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS WITH N 5 AND LABELS INTACT AND LEGIBLE SHOULD A CONFLICT OR DISCREPANCY EXIST BETWEEN MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND THOSE ON THE DRAWINGS, THE TENANT &C. SHALL CONTACT DRESS BARN PRIOR TO FURTHER WORK IN THE AREA OF QUESTION. 33. DRESS BARN HAS CHOSEN MATERIALS FOR USE ON THIS PROJECT AS SPECIFIED UPON AWARD OF THE CONTRACT. THE SPECIFIED MATERIALS SHALL BE ORDERED IMMEDIATELY AND ALL DELIVERIES CONFIRMED TO MEET THE COMPLETION DATE. DELAYS IN ORDERING, RESULTING IN MATERIALS NOT BENG AVAILABLE TO THE TENANT SC. FOR COMPLETION OF ALL WORK ON SCHEDULE AND RESULTING N EXTRAS WILL BE THE RESPONSIBILITY OF THE TRADE RESPONSIBLE FOR SUCH DELAYS. MATERIALS THAT ARE UNAVAILABLE FOR INCLUSION IN THE PROJECT AS A RESULT OF DELAYS AND REQUIRE DRESS BARN AND THE OWNER TO CHOOSE AND APPROVE NEW REPLACEMENT MATERIALS SATISFACTORY TO THE PROJECT MAY RESULT IN BACK CHARGES TO THE SAID TRADE UNI FS THE OWNER HAS BEEN ADVISED WITH SUFFICIENT TIME TO MAKE SUCH MATERIAL REVISIONS. 34. THE TENANT 0.C. AGREES TO ACCEPT ALL DRESS BARN FURNISHED ITEMS AT THE JOB SITE OR DESIGNATED STORAGE SPACE AND UNLOAD THESE ITEMS FROM THE TRUCK BED OF DELIVERY CARRIER AND TRANSPORT TO STORE PREMISES. ITEMS DELIVERED TO A DESIGNATED STORAGE SPACE ARE TO BE DELIVERED TO JOB SITE BY CONTRACTOR. 38. DELIVERY OF TIENANT.FURINSHED non THE TENANT EG WILL ADVISE THE DRESS BARN IN WRITING, WITHIN THREE (3) DAYS AFTER AWARD OF THE CONTRACT, OF THE EXACT DELIVERY PATES AND LOCATIONS HE WISHES TO RECEIVE ALL FURNISHED ITEMS. ITEMS NOT SCHEDULED WITHIN THREE IN DAYS WILL BE SCHEDULED AND DELIVERED AT DRESS BARN'S OPTION 36. THE TENANT G.C. SHALL BE RESPONSIBLE FOR SECURITY OF THE PROJECT AND MATERIALS WHETHER STORED WITHIN THE PREMISES OR ELSEWHERE UNTIL THE POINT OF 'SUBSTANTIAL' COMPLETION. THIS SHALL INCLUDE ALL OWNER AND LANDLORD FURNISHED ITEMS ACCEPTED BY THE TENANT G.C. 37. PRESS BARN, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK, ALTER, ADD TO OR DEDUCT FROM THE CONTRACT. THE CONTRACT SUM AND COMPLETION DATE SHALL BE ADJUSTED ACCORDINGLY. 3S THE TERMS EQUAL OR APPROVED EQUAL SHALL REQUIRE REQUESTS FOR SUBSTITUTIONS FOR PRODUCTS OR MANUFACTURERS NOT SPECIFIED. REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED WITHIN THREE (5) CALENDAR DAYS PRIOR TO PATE OF BID SUBMISSION. APPROVED SUBSTITUTIONS SHALL BE LISTED IN AN ADDENDUM TO THE CONTRACT. 39. WHEN REQUIRED BY THE BUILDING DEPARTMENT, THE TENANT C.C. SHALL COPIES) SHOP DRAWINGS 12 ) FOR THE FIRE PROTECTION SPRINKLERS (WITH FRE MARSHALS AND UNDERWRITERS APPROVAL THEREON) ELECTRICAL PANELS, SWITCH GEAR AN D TRANSFORMERS AIR CONDITIONING EQUIPMENT, PLUMBING FIXTURES, STRUCTURAL STEEL, MISCELLANEOUS IRON WORK AND ALL OTHER ITEMS INDICATED ON THE DRAWINGS 40. NO PORTION OF THE WORK REQUIRNG SUBMISSION OF A SHOP DRAWING. PRODUCT DATA OR SAMPLES SHALL BE COMMENCED UNTIL P 4 A N. ALL SUCH THE SUBMITTAL HAS BEEN APPROVED BY PR S BARN. PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH APPROVED WITH APPROVED SUBMITTALS 44 THE TENANT G.C. SHALL NOT BE RELIEVED FROM RESPONSIBILITY FOR ERRORS OR OMISSIONS IN THE SHOP DRAWINGS. PRODUCT DATA OR SAMPLES. THE 42 � TENANT G.C. SHALL AT ALL TIMES AFFORD ACCESS TO DRESS 2 TH BARN LANDLORD AND/OR AGENTS AND EMPLOYEES TO THE PROJEC T STORE TO OR WORK WHEREVER IT 15 IN PREPARATION AND PROGRESS. THE TENANT SC, SHALL PROVIDE FACILITIES NECESSARY FOR SUCH ACCESS FOR DRESS BARN OR LANDLORD TO PERFORM THEIR FUNCTIONS UNDER THE CONTRACT DOCUMENTS AND DRAWNGS 43. THE TENANT G.C. SHALL BE RESPONSIBLE FOR OBTAINING A CERTIFICATE OF OCCUPANCY FROM THE GOVERNING AUTHORITY. 44. THE TENANT G.C. SHALL PROVIDE A PROFESSIONAL CLEANING SERVICE FOR ALL AREAS OF THE STORE AT THE COMPLETION OF THE PROJECT AND BEFORE TURNING THE SPACE OVER TO DRESS BARN. WORK TO INCLUDE BUT NOT TO BE LIMITED TO REMOVAL OF ALL TRACES OF SOIL, WASTE MATERIALS, SMUDGES, AND FOREIGN MATTER REMOVE ALL TRACES OF SPLASHED MATERIAL FROM ADJACENT SURFACES. REMOVE PAINT DROPPINGS SPOTS, STAINS, AND DIRT FROM FINISHED SURFACES CLEAN STORE FRONT GLASS ON BOTH SIDES AND ALL MIRRORED SURFACES TO SURFACES REQUIRING POLISH, APPLY POLISH RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL BEING POLISHED, FLOORING REQUIRING WAXING, AFTER ADHESIVE HAS FULLY DRIED, SHALL HAVE ANY DRIED ADHESIVE REMOVED. THE FLOOR SHALL BE CLEANED AND WAXED USING MANUFACTURER'S RECOMMENDED CLEANING AND WAXING MATERIALS ONLY. L NOTES ADDRESS: ent Drawings 45 EXISTING CONCRETE FLOOR TO BE PATCHED AND REPAIRED AS REQUIRED TO RECEIVE NEW FLOOR FINISHES FLOOR SLOPED AS REQUIRED. A MINIMUM OF 24' FOR AN EVEN AND FLUSH TRANSITION BETWEEN VARYING NEW AND /OR EXISTING FLOOR FINISHES. 46. ALL DIMENSIONAL LUMBER, PLYWOOD, PARTICLE BOARD, ETC. USED IN CONSTRUCTION SHALL BE PRESSURE TREATED, ILL CERTIFIED, NON - COMBUSTIBLE. ALL LUMBER IN CONTACT WITH CONCRETE, MASONRY OR EARTH SHALL BE TREATED WITH PRESERVATIVE 47. CARPENTRY CONTRACTOR TO PROVIDE WOOD BLOCKING, FURRING, SUPPORTS, ANCHORS, ETC. AS REQUIRED FOR F51'IJRES. STANDARDS, ELECTRICAL, PLUMBING, ETC, AND PROVIDE CUTTING AND PATCHING REQUIRED FOR WORK OF OTHER AREAS 45 ALL FEL.D LAMINATES SHALL BE DONE N STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS REGARDING THE APPLICATION OF LAMINATES. SET UP OR BLOCKING APPARATUS AND APPLICATION TECHNIQUE SHALL BE HELD AS NEAR AS POSSIBLE TO CARNET SHOP SITUATIONS. PARTICLE BOARD SHALL BE FREE OF SHEET DEFECTS AND SHALL BE CUT WITH A CARBIDE TIPPED SAW TO AVOID SPLINTERING. LAMINATE SHALL BE APPLIED AS PER MANUFACTURER'S SPECIFICATIONS AND SHALL BE OVER CUT TO ALLOW EDGE TRIMMING WITH A ROUTER. ALL LAMINATES SHALL BE SECURELY CLAMPED TO THE BACKING UNTIL POSITIVE ADHESION 15 ATTAINED. 49. WORK IN PLACE THAT IS SUBJECT TO DAMAGE BECAUSE OF OPERATIONS BEING CARRIED ON ADJACENT THERETO SHALL BE COVERED, BOARDED UP OR SUBSTANTIALLY ENCLOSED N SUCH A MANNER SUCH THAT UPON COMPLETION THE ENTIRE WORK WILL BE DELIVERED IN PROPER UNBLEMISHED CONDITION. 50. FINISHED CARPENTRY WORK SHALL BE ERECTED PLUMB AND SQUARE COPED AT NEVE CORNERS, MITERED AT OUTSIDE CORNERS IN ACCORDANCE WITH THE DRAWNGS. ALL SURFACES TO BE SANDED SMOOTH AND EVEN. DRILL ALL HARDWOOD NAIL HOLES TO PREVENT SPLITTING BLIND NAIL WHERE POSSIBLE AND ALL SURFACE NAILS TO SET. FLAT TRIM TO BE BACKED OUT TO PREVENT WARPING. NAIL HOLES, CRACKS AND OTHER DEFECTS TO BE TREATED TO RENDER THEM UNNOTICEABLE. EL STOCK ROOM SHELVING TO BE SUPPLED AND INSTALLED BY TENANT G.C. 62 ALL DOORS AND DOOR HARDWARE PROVIDED AND INSTALLED BY THE CARPENTRY CONTRACTOR. S DOOR SCHEDULE FOR EXCEPTIONS. COMMERCIAL GRAPE FINISH HARDWARE, LABELED WHERE REQUIRED, SHALL BE USED THROUGHOUT. 63. SOLID CORE WOOD DOORS SHALL BE MANUFACTURED IN ACCORDANCE WITH THE LATEST NATIONAL WOODWORK MANUFA ASSOCIATION INDUSTRY STANDARD. POOR HARDWARE SHALL 55 RUSSWIN, SCHLAGE, YALE OR CORBIN. FINISH TO BE US25O OR US32D. ROLL -UP GRILLE (WHEN REQUIRED) TO BE FURNISHED AND INSTALLED BY THE GRILLE CONTRACTOR_ 94. METAL STUD SYSTEM TO BE CONSTRUCTED AS FOLLOWS: FOR PARTITIONS UP TO AND INCLUDING 16' -6' IN HEIGHT, 3-5/8' 25 GAUGE STUDS AT 16' ON CENTER. FOR PARTITIONS ABOVE 15'-8' IN HEIGHT 5-I /T 20 GAUGE STUDS AT 46' O.G ALL PARTITIONS ADJACENT TO OTHER LEASE OR COMMON AREAS TO HAVE 5 /B' =IRE CODE GYPSUM BOARD ON ONE SIPE, FIRE TAPED AND SPACKLED AC JOINTS GYPSUM WALL BOARD SHALL BE INSTALLED WITH ALL CORNER 55 PSUMf W RI7 BEADS, TRIM ACCESSORIES AND MOLDINGS, ETC. AS REQUIRED FOR COMPLETION. TAPED AND SANDED READY FOR PANT BY DRYWALL CONTRACTOR. REPAIR AND PATCH EXISTING WALLS AS REQUIRED TO ACCEPT NEW FINISHES. 56. ALL MIRRORS FITTING AND GLASS N SALES AREA AND FTING ROOMS TO HAVE POLISHED VERTICAL EDGES. SECURE MIRROR WITH MASTIC OR AS SECURED. GLAZING CONTRACTOR TO ALSO PROVIDE AND INSTALL CHANNEL TRIM, BREAK METAL CLIPS, ETC. AS REQUIRED AND AS DETAILED FOR SAME MIRROR. TENANT G.C. SHALL SEAL EDGE OF SPACE BETWEEN MIRROR BACKS AND WALL WITH SILICONE. 57, SPRINKLER& WORK AND APPARATUS SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH LATEST NATIONAL FIRE PROTECTION ASSOCIATION STANDARD NC. 13. IN FINISHED ROOMS,' - ' ALL SPRINKLER SYSTEM PIPING SHALL BE CONCEALED. PROTECTION AREA PER SPRINKLER SHALL NOT EXCEED ONE HUNDRED - THIRTY (1301 SQUARE FEET IN SALES ROOM AND ONE - HUNDRED 11001 SQUARE FEET IN SERVICE ROOM. SPRINKLER HEADS SHALL BE UL AND RM APPROVED. HIGH SENSITIVITY GLOW BULB TYPE, CHROME PLATED, AND NOTED 166 DEGREES TEMPERATURE RATING. SPRINKLER HEADS LOCATED N SHOW WINDOW SHALL BE RECESSED TYPE. ALL OTHER SPRNKLER HEAPS LOCATED IN SALES ROOM SHALL BE SEMI-RECESSED TYPE UPON COMPLETION OF INSTALLATION, THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT A WRITTEN CERTIFICATE TO THE OWNER FROM THE UNDERWRITER STATING THAT THE SYSTEM WAS INSPECTED AND APPROVED. 55. WATERPROOF FLOORS (EMPLOYEE TOILET ROOM) WHEN REQUIRED: ALTERNATE *1- 3-1/2' OF SMOOTH FINISH CONCRETE. ALTERNATE : - 4' OF MAGNESITE OR OTHER ACCEPTABLE SUBSTITUTE LAID OVER HEAVY WIRE SCREENING. SCREEN AND FLOOR COVERING TO BE CARRIED UP WALL 6', ALTERNATE E3 - ALOUD VINYL - ACRYLIC COPOLYMER WATERPROOFING AGENT. 59. THE TENANYOA. SHALL PROVIDE ALL NECESSARY MATERIALS EXCEPT FOR THOSE SPECIFIED TO BE FURNISHED BY DRESS BARN, AND LABOR TO INSTALL A COMPLb FE ELECTRICAL SYSTEM AS SHOWN ON THESE DRAWNGS. WORK TO INCLUDE: (WHEN REQUIRED, COMPLETE LIGHT AND POWER SERVICE, STANDARD METERING, ALL WIRING NECESSARY FOR OPERABLE LIGHTING AND POWER SYSTEM; COMPILE I B WIRING FOR AND FINAL CONNECTION TO ALL MECHANICAL EQUIPMENT, INCLUDING POWER AND CONTROL WIRING FOR HEATING AND AIR CONDITIONING EQUIPMENT, FIRE AND SPRINKLER ALARM CIRCUITS EMERGENCY AND LIGHTING CIRCUIT WIRING TO SYSTEM; C1 WIRING TO R EXIT S R SIGNS; WIRING FOR NETWORK COAXIAL SYSTEM; WIRING FOR TELEPHONE SYSTEM; EMPTY CONDUITS FOR FUTURE WIRING; ALL EQUIPMENT AND SYSTEM GROUNDS IN COMPLIANCE WITH APPLICABLE CODES; PERMITS, INSPECTIONS AND CERTIFICATES; CHARTING ALL SWITCHBOARDS AND PANEL BOARDS AND PROPER PHASE CODING AND BALANCE KEY PLAN SCLTHCEN I ER SQUA ,E 1 17250 SOU ° I ICES ER AVE. WASI 96166 DRESS BARN 60. THE TENANT G.C. SHALL PROVIDE ALL NECESSARY MATERIAL AND LABOR (WHEN REQUIRED) FOR A COMPLETE HEATING AND AIR CONDITIONING SYSTEM. WORK TO INCLUDE A COMPLETE HVAC SYSTEM, BASED ON THE LATEST ASHRAE DESIGN CRITERIA; EXHAUST AND TRANS FANS; NATURAL GAS SERVICE AND PIPING; DIFFUSERS AND GRILLES; DUCTWORK AND INSTALLATION SMOKE CONTROL SYSTEM; FIRE DAMPERS; ACCESS DOORS INTO DUCT; LOUVERS; ROOF VENTILATION; •INTAKES• MOTORl2EP DAMPERS CLEANA'I G TEST, ADJUSTING AND BALANCING; GUARANTEES AND WARRANTEES WHEN AN EXISTING HVAC AND EXHAUST SYSTEM IS TO REMAIN, THE TENANT G.C. SHALL RELOCATE DIFFUSERS AND DUCTWORK AS REQUIRED BY NEW WORK; INSPECT AND REPAIR SYSTEM AS NECESSARY TO ENSURE PROPER OPERATION CONFIRM THAT SYSTEM IS FULLY OPERABLE ANP WILL MAINTAIN HEAT AND COOLING TEMPERATURES WITHIN THE I EASED PREMISES N ACCORDANCE WITH THE LOCAL REQUIREMENTS. EL THE TENANT G.C. SHALL PROVIDE ALL NECESSARY MATERIALS AND LABOR (WHEN REQUIRED) FOR A COMPLETE PLUMBING SYSTEM, WORK TO INCLUDE THE FOLLOWING: SANITARY DRAINAGE SYSTEM; COLD WATERING SYSTEM, INCLUDING WATER METER HOT WATER SYSTEM INCLUDING WATER HEATER, PIPE COVERING; PLUMBING FIXTURES, FLOOR DRAINS, UTILITY SINK, PAPER TOWEL DISPENSER, MIRROR, SOAP DISPENSER, GRAB BARS FOR PHYSICALLY HANDICAPPED, CLEANING AND PROTECTION, PERMITS AND INSPECTION, IDENTIFICATION TAGS, TESTS, GUARANTEES AND WARRANTIES TOILET ROOMS SHALL CONFORM TO ALL ACCESSIBILITY REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A) El C) PI El F) G) H) K) L) 62 JUNCTION BOXES FOR EXTERIOR SIGNS SHALL BE MOUNTED ON INSIDE FACE OF BULKHEAD ABOVE CEILING / OR AT INSIDE FACE OF CANOPY W /ACCESS PANEL PROVIDED. DISTANCE FROM JUNCTION BOX TO EACH SIGN NOT TO EXr'EBII 1O' -O'. (REFER TO SIGN DRAWINGS FOR ACTUAL SIGN LOCATIONS). Si, THE TENANT G.C. SHALL PAINT INTERIOR FACE OF BULKHEAD AND STOREFRONT WHERE REQUIRED. TENANT G.C. WILL BE RESPONSIBLE FOR ANY REPAIRS TO FASCIA ON ALL REMODELS AND OR EXPANSIONS WHERE THE SIGNAGE IS REVISED OR RELOCATED. 84. NOTE: 1/4' DIA. HLTI TOGGLER BOLT WITH PHILIPS FLAT HEAD SCREWS SHOULD BE USED ON ALL WALL STANDARDS. X07- 190 WATER CLOSET SEAT HEIGHT - 17' TO 19' AFF. CENTER LINE OF WATER CLOSET - 18' FROM SIPE WALL GRAB BAR BEHIND WATER CLOSET - 36' LENGTH, 33 -3B' AF.F. GRAB BAR DIAM - 1-1/4' TO 1-/2' SPACE BETWEEN WALL AND GRAB BAR - 1-1/2' TOILET PAPER DISPENSER - 36' MAX FROM REAR WALL, 19' MN. A.F.F. KNEE CLEARANCE AT LAVATORY - APRON 29' MIN. HT, B' MIN. DEPTH LAVATORY DEPTH - IT MN. LAVATORY HOT WATER 6 DRAIN PIPES INSULATED WHERE EXPOSED. LAVATORY RIM SURFACE - 34' MAX A.F.F. MIRROR BOTTOM EDGE - 40' MAX. A.F.F. INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE MOUNTED ON THE EXTERIOR OF TOILET ROOM DOOR INSURANCE REQUIREMENTS ALL CERTIFICATES OF INSURANCE MUST IDENTIFY THE DRESS BARN, INC AND THE LANDLORD AS 'ADDITIONAL INSURED' ON THE CONTRACTOR'S POLICY AND CONTAIN A FIFTEEN DAY WRITTEN NOTICE OF CANCELLATION CLAUSE. CONTRACTORS SHALL ALSO COMPLY WITH INSURANCE THAT MAY RE REQUIRED BY THE PROPERTY OWNER AND /OR PROPERTY MANAGEMENT. CONPREHEIO5WE GENERAL LIABILITY THIS POLICY MUST INCLUDE BODILY INJURY AND PROPERTY DAMAGE, LIABILITY COVERAGE, CONTRACTUAL LIABILITY, COMPLETED OPERATIONS AND BROAD FROM PROPERTY DAMAGE COVERAGE BODILY INJURY LIMITS OF COVERAGE LIMITS OF COVERAGE .2,000.000 PER PERSON 53,000,000 PER OCCURRENCE PROPERTY DAMAGE 3600,000 PER OCCURRENCE COMBINED SINGLE LIMIT 52.000,000 BODILY INJURY AND PROPERTY DAMAGE WORKER'S COMPENSATION AND EMPLQYER'S LIABILITY THE CONTRACTOR'S CERTIFICATE OF INSURANCE MUST EVIDENCE BOTH COVERAGES AND MUST BE RECEIVED PRIOR TO COMMENCEMENT OF WORK WORKERS COMPENSATION COVERAGE IS STATUTORY IN EACH STATE THEREFORE, NO LIMIT NEED BE I I I LSTRATED. EMPLOYERS LIABILITY COVERAGE MUST BE EVIDENCED WITH A MINIMUM OF 51,000,000 EACH ACCIDENT. COMPREHENSIVE AUTOMOBILE LIABILITY INSURANCE INCLUDING THE OPERATION MAINTENANCE, IKON AND /OR USE OF ANY AUTOMOTIVE EQUIPMENT. TENANT G.C. SHOULD REFER TO GENERAL CONDITIONS OF DRESS EARN CONTRACTS FOR SPECIFIC COVERAGE INFORMATION NOT WRH$TANPNG ANY HVG TO THE CONTRARY SET NORTH FERM. IT IS UNDERSTOOD AND AGREED THAT SOME OP TFS NOTES GONTAN D HEREIN MAY LOT PERYAS TO THE PARTICULAR PROJECT FOR WHICH YOU ARC REUSE WF✓BENEYER THERE L5 CONFLICT BET' EGI THE NOTES CONTAMIT NGRF ANO'RE PIaiS WHICH NGYE BEEN Pug:S ED THE PROVISIONS OP THE PLAN SHALL CONTROL. ILrT�• G ] s.r v 'I - CoDE COMPLIANCE APPROVED S'EP 2 4 2001 0 Of Tukwila DIN IVISION SEP 12 2007 jVi N NOTE: LANDLORD IS RESPONSIBLE FOR H.V.A.C., FIRE PROTECTION AND PLUMBING DRAWINGS. DRAWINGS SHALL BE COMPLETED IN ACCORDANCE WITH DRESS BARN TENANT IMPROVEMENT DRAWINGS AND DRESS BARN WHITE BOX SPECIFICATION /LEASE EXHIBIT. • • 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614 -0209 fax • • • THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER. NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. `C,3 ety; z O � z z o Q • Z z W z W ®G W cr e W IA CSC 4 eD 0,4 ,.c95eLf4 Z z W 0 a) O 0 Seal: Job No: Date: Scale: Drawn: Checked: Revisions: Sheet: I- 340:1, 31.,. ;, (IM I DA A liDKi STATE OF W sSHi 1 TUKWILA, WA JULY 2, 2007 1/8"=V SB /E0 /WS DAU / \ 7/13/07 REVISE SIGN HEIGHT (ED) A 8/15/07 BLDING DEPT COMMENTS (E0) /A\ 9/6/07 BLDING DEPT COMMENTS (ED) Of: 12 El • •1111111111111111111111111111111111M111111111111• 5' r 1 T-5' , .4 -2• , 5_6 1 1 � HOW c1 — r 17' -1' ' .Z -.OY i I I 5I 7' -5' - 4' -2' " r 5' -6' IF HOLD 17' -11' i0 N. 1 4 7/8' 5/8" G.W.B. SCALE: N.T.S. WALLS LANDLORD SHALL PROVIDE: PLUMBING LANDLORD SHALL PROVIDE: 5/8° G.W.B. METAL TRACK SHIM AS REQUIRED HOLLOW METAL DOOR FRAME I�f HOLLOW METAL DOOR FRAME 3 5/8" WOOD STUDS 3 5/8' METAL STUDS TYPICAL METAL DOOR HEADER/JAMB LANDLORD'S CONTRACTOR HAS 5 DAYS TO COMPLETE TENANT'S PUNCH LiST OR TENANT SHALL HAVE THE RiGHT TO COMPLETE THE WORK AT LANDLORD'S EXPENSE. NO BLOCK OR MASONRY WALL OR TEXTURED FINISH ACCEPTED WiTHOUT WRITTEN APPROVAL OF TENANT. 1F, FiRE EGRESS REQUIRES FIRE RATED CORRIDOR, IT WiLL BE PROVIDED FOR THE EXCLUSIVE USE OF TENANT WITH THE APPROPRIATE DOORS, LOCK SETS AND SAFETY FEATURES. EXTERIOR WALLS MUST BE INSULATED TO AN R1'1 RATING AS WELL AS HAVE 5/8" SHEET ROCK ON 3 5/8" METAL STUDS 16" ON CENTER THROUGHOUT. ONE COMPLETELY ENCLOSED TOILET ROOM, OR AS MANY AS REQUIRED BY CODE, INCLUDING TOILETS, WASH BASIN, COLD AND HOT WATER (MINIMUM 6 GAL. ELECTRIC), COMBINATION FANLIGHT FIXTURE WiTH WALL SWITCH, Y.C.T., SLOP SINK AND WATER FOUNTAIN AS REQUIRED BY CODE LOCATED IN ACCORDANCE WiTH TENANT'S PLANS AND SPECIFICATIONS. ALL MUST MEET LOCAL OR FEDERAL MiNIMUM HANDICAPPED REQUIREMENTS, WHICHEVER 1.5 GREATER. LANDLORD SHALL OBTAIN FULL AND COMPLETE WARRANTIES (WHICH WiLL REMAIN IN EFFECT 1 YEAR) FOR ALL HVAC, ELECTRICAL AND PLUMBING EQUIPMENT FROM THE CONTRACTOR PROVIDING SAiD SERVICES AND FORWARD TO TENANT FOR ITS RECORDS. LANDLORD TO PROVIDE FULL AND FINAL UTILITIES HOOK UP, SEPARATELY METERED TO TENANT SPACE READY FOR REASSIGNMENT TO TENANT ACCOUNT PRiOR TO POSSESSION. NO COMMON AREA SHARED UTILITIES (LE. SPRINKLER RiSERS, ELECTRICAL SWITCH GEAR, ROOF ACCESS, ETC.) SHALL BE LOCATED iN TENANT'S SPACE WiTHOUT TENANT'S WRITTEN APPROVAL. DOOR NO. 1 NSA NIA 4 5 BLOW UP OF CENTER WALL FITTING ROOMS SCALE: N.T.S. DRYWALL CORNER BEAD - TAPE AND SPACKLE, READY FOR PAiNT (TYP) 3 5/8" METAL STUD 5/8' SHEET ROCK 1/2° X 1/4° BLACK REVEAL 3/4' BLOCKING TO BE LAMINATED PL -1 ON ALL (4) SIDES 17' -11' -5' 5' TENANT G.C. SHALL PAiNT INSIDE CORNER OF THE SHEET ROCK BLACK TO MATCH THE BLACK REVEAL (TYP) TRIM CAP DETAIL @ SALES AREA FITTING ROOMS SCALE: N.T.S. NOTE TRIM CAPS REVEAL TO BE SUPPLIED BY MILLWORK COMPANY S INSTALLED BY TENANT G.C. NOTE TRIM CAP TO BE SECURED TO SHEET ROCK WALL WITH GLUE. NOT ONLY TO BE USED IN SALES AREA WHERE INDICATED. SIZE 3'- O "X7' -O" 36" X 66' 32° X 66° 36" X 66" 3' -O' X 6' -8" DOOR SIZE DESCRIPTION DOUBLE DOOR ENTRANCE FITTING ROOM - HOLLOW WOOD FITTING ROOM - HOLLOW WOOD FITTING ROOM - HOLLOW WOOD SOLID WOOD FINISH GLASS LAMINATE LAMINATE LAMINATE PAiNT DRYWALL CORNER BEAD - TAPE AND SPACKLE, READY FOR PAINT (TYP) 3 5/8" METAL STUD ALUM. WOOD WOOD WOOD METAL 5/8' SHEET ROCK 1/2" X 1/4' BLACK REVEAL 3/4° BLOCKING TO BE LAMINATED PL -1 ON ALL (.4) SIDES TRIM CAP DETAIL @ END OF SHEET ROCK WALL SCALE: N.T.S. NOTE: TRIM CAP REVEAL TO BE SUPPLIED BY MILLWORK COMPANY S INSTALLED DY TENANT O.C. NOTE TRIM CAP TO BE SECURED TO SHEET ROCK WALL. WITH GLUE. NOTE: ONLY TO BE USED IN SALES AREA WHERE INDICATED. NEW STORE FRONT BY LANDLORD. TENANT G.C. TO INSTALL NEW PLYWOOD BACKER AND PATCH /REPAIR DRYWALL AS REQUIRED FOR THE INSTALLATION OF NEW PUCKS. U) NEW STORE FRONT BY LANDLORD, FRAME MATERIAL FINISH BLDG. STND. LAMINATE LAMINATE LAMINATE PAINT [- 4 L 6 15s JAMB TYPE DOOR SCHEDULE HDW. NO. #1 #K5 #6 #6 #2 TENANT G.C. SHALL PAINT INSIDE CORNER OF THE SHEET ROCK BLACK TO MATCH THE BLACK REVEAL (TYP) DOOR NO. 6 7 NWA 14/A 10 SIZE 3' -O" X 6'-6" 2' -6" X 6' -8" 3 -O" X 6' -8° 3' -O' X 6' -8' 3 -0' X 7' -O' DRYWALL CORNER GUARDS SUPPLIED BY MILLWORK COMPANY AND INSTALLED BY TENANT G.C. WHERE INDICATED ON THiS PLAN. CORNER GUARDS SHALL BE 8' -0" W-CG-V2 WALL WEAR, MOONLIGHT 2" CORNERS SUPPLIED BY MILLWORK COMPANY. CORNER GUARDS DOOR SIZE DESCRIPTION SOLID WOOD SOLID WOOD HOLLOW METAL CLASS "C° RATED ASSEMBLY HOLLOW METAL CLASS "C" RATED ASSEMBLY HOLLOW METAL MINIMUM 16 GUAGE CLASS 'C' RATED ASSEMBLY 81' -11" FINISH MATERIAL PAiNT METAL PAINT METAL PAiNT METAL PAINT METAL PAINT METAL METAL "L' ANGLE GYPSUM BOARD SCALE: N.T.S. FRAME FINISH PAINT PAINT PAiNT PAINT PAINT MIRROR WiTH POLISHED VERTICAL EDGES (SEE PLAN FOR DIMENSIONS) ti JAMB HDW. TYPE NO. O #3 #8 #9 #3 #4 NEW TOILET ROOMS BY LANDLORD. SINK TO HAVE DELTA 2170 WiTH 10° GOOSENECK OR EQUIVALENT LANDLORD. TENANT G.C. TO INSTALL TWO (2) 4' -0" LONG STANDARDS AND BRACKETS ABOVE TOILET FIXTURE, 2' -0' O.C., SUPPLIED BY DRESS BARN. TENANT G.C. TO CUT STANDARD TO 4' -0' LENGTH. TENANT G.G. TO FURNISH AND INSTALL THREE (3) SHELVES. DRYWALL CORNER BEAD (TYP) NOTE TRIM GAPS REVEAL TO BE SUPPLIED BY MILLWORK COMPANY 8 INSTALLED BY TENANT G.G. NOTE: TRIM CAP TO BE SECURED TO SHEET ROCK WALL WITH GLUE NOTE, ONLY TO BE USED IN SALES AREA WHERE INDICATED. METAL 'L' ANGLE MASTIC 5/8° SHEET ROCK (TYP) - 3 -5/8' METAL STUD (TYPE 1/2' X 1/4° BLACK REVEAL LAMINATE & MIRROR DETAIL FOR DISPLAY WALLS & TRIM CAP DETAIL @ END OF SHEET ROCK WALL NEW REAR DOOR BY LANDLORD EXTERIOR REAR DOOR TO BE PAINTED DARK GRAY OR BUILDING STANDARD COLOR BY LANDLORD, INTERIOR SiDE OF REAR DOOR TO BE PAINTED SEMi -GLOSS DARK GRAY BY TENANT G.C. LANDLORD TO FURNISH AND INSTALL DOOR LOCK. REAR DOOR ALSO TO HAVE A PEEP HOLE ® 5' -O' A.F.F. WEATHER STRiPPiNG 8 DOOR SWEEP TO BE INSTALLED AS REQUIRED BY LANDLORD. t• PUCKS SUPPLIED BY m DRESS BARN AND INSTALLED AT 7' -9' A.F.F. BY TENANT G.C. 46' - 0' PUCKS SUPPLIED BY DRESS BARN AND INSTALLED AT 7' -9" A.F.P. BY TENANT G.C. MIRROR 9' -9n _ 2-0' 2�-O' 2'-0' 2 3' 12' 2'-0' 1/2' 10' -9" MIRROR 36' -2" N 14' -8" 2I 11' -9" PREFABRICATED UNIT 2' 3 12' 12' 2'-0' 2' -0' 12' 12' 2'-0" 12 r -O" 2'-O' 2'-O' 2-0' 2 14' -8" PREFABRICATED UNIT 36 COLUMN TO BE ENCLOSED AS TIGHT AS POSSIBLE BY TENANT G.C. PAINT PT -1. INSTALL (4) CORNER GUARDS FOR EACH COLUMN (TYP). DRESS BARN WOMAN SALES AREA 2' 4 1/2' 10''9" .4 1/2' 2.-0' 2.-o• 2'-O' r-0' DRESS BARN SALES AREA 2'-a• 2 17' -11" HOLD 17' -11" HANG BAR SUPPLIED BY MILLWORK COMPANY AND INSTALLED BY TENANT O.C. E 5'-O' A.F.F. MRROR 2 2' -0' 2'-O 2'-0 PREFABRICATED UNIT TENANT G.C. SHALL BOX IN COLUMN AS REQUIRED TO ACCOMMODATE POWER AND COMMUNICATION'S CONDUIT. 17' -1" NOTE NEW CASH WRAP AND BACK BAR TO BE PREFABRICATED (SEE DETAIL SHEET). ENTRANCE TO REAR AREA FITTING ROOMS IS TO BE UNCASED FROM FLOOR TO CELINIG. 9' -6" 19 -O" F. 12 -11" 6' r-O' 2'-O' 2'-O• 2'-O' Z'-O• 2' 2 O' 2' -0' 7-0' MIRROR 3 -WAY STOCK ROOM AREA NOTE: 1'X6' PRE FAB HEADER (TYP). S O' 2' -0' 2'-O• 2' 12' 7-0 •. .1_•IOf. U. 1 2'-O• 2'-O" 2' -0' II a .1: - 1+. D ' 3 -5" 10' -O" r 2 14' -8'� z' 2 8' -8" PREFABRICATED UNIT 8' -6' 77' -2" 14' -8" 116' -11" 2 3' 71_311 3• yl!i(I� 2' -O• 2' -0' 2'-O' I - �a�(•.�a 1 62,^ , 34' -1" EGRESS CORRIDOR © 5•A• 26 -4" 17-3' 33'X39' FRAME FOR POSTER. TENANT G.C. TO INSTALL SCREWS PER. DETAIL 4. POSTER TO BE INSTALLED BY STORE PERSONNEL AT A LATER DATE. - THUMB TURN LOCK 'BEST' * 3606060 OR KEYED LOCK WHEN REQUIRED. KEYED LOCK TO BE ACCOMPANIED BY SiGN: 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS'. DOOR TO HAVE GLYNN- JOHNSON 5444 KiCK DOWN HOLDER OR EQUAL. FINISH TO MATCH STOREFRONT DOORS. 2 - DOOR CLOSER' W/ HOLD OPEN DEVICES. PULL: 'HAGER' #A39E - 3 1/2' X 45' BRUSHED ALUMINUM FiNiSH PUSH: 'HAGER' #A3OS - 3 1/2' X 15' BRUSHED ALUMINUM FiNISH 1$' SATIN BRUSHED ALUM. KICK PLATE 3 - PRIVACY LOCK SET, DOOR CLOSER, STOPS 6 SILENCERS, LEVER TYPE HANDLE REQUIRED (ADA ACCESSIBLE) 34' -6" NOTE: 24 "X6O' MiRROR SUPPLIED BY TENANT G.G. INSTALLED ON REAR FiTTING ROOM PANEL (TYP) TENANT G.C. SHALL PAiNT INSIDE CORNER OF THE SHEET ROCK BLACK TO MATCH THE BLACK REVEAL (TYP) HARDWARE SETS 3/4' BLOCKING TO BE LAMINATED PL -1 ON ALL (4) SIDES NOTE: BENCH CAPABLE OF SUPPORTING 250 LB LOAD. *4 - PANIC PUSH BAR FOR METAL DOORS FIRE RATED SUPPLIED AND INSTALLED BY DRESS BARN DOOR CLOSER "CORBIN' SERIES DC3200540F12 BY LANDLORD INSTALL U.L. LiSTED DOOR ViEWER 3 5'-O' A.F.F. BY LANDLORD. PULL HANDLE BOTH SIDES OF DOOR BY TENANT 6.C. 55 - LEVER TYPE HANDLE REQUIRED (ADA ACCESSIBLE) - KEYED LEVER TYPE LOCK SET WiTH PRIVACY LATCH (ADA ACCESSIBLE). 57 - LEVER PASSAGE SET #5 - KEYED LOCK SET, LEVER TYPE HANDLE REQUIRED FURNISHED BY DRESS BARN. 59 - LEVER PASSAGE LATCH SET (ADA ACCESSIBLE). DOOR CLOSURE WITH HOLD OPEN DEVICES AND 15' SATIN BRUSHED ALUM. KICK PLATE VARIES 33' 48' BUILDING SERVICE CORRIDOR NOT PART OF DRESS BARN SPACE 9 4 TENANT G.C. SHALL PROVIDE AND INSTALL H1LTI TOGGLER WiTH MACHINE SCREWS FOR HANGING FRAME. SMALL FRAME ON FITTING ROOM WALL SCALE: N.T.S. MUSIC /STEREO SHELF TO BE MOUNTED 0 6' -O" A.F.F. BY OTHERS COMPUTER STAND BY OTHERS. COMPUTER SHELF TO BE MOUNTED 0 5' -O" A.F.F. BY OTHERS. LANDLORD TO MAKE SURE THE REAR STORE AREA IS PROPERLY VENTILATED. INTERIOR DISPLAY WALL LANDLORD TO MAKE SURE THE REAR STORE AREA 1S PROPERLY VENTILATED, LANDLORD MUST PROVIDE CONTINUOUS 12" 20 GUAGE METAL STRAPPING 2' -0' O.C. STARTING AT 3' -9° A.F.F. AT PUCK LOCATION. (TYPICAL) SEE ELEVATION E ON SHEET 6 O O 4' -2" FINISHED DRYWALL OPENING CLEAR TO ACOUSTICAL CEILING ABOVE I PLAN VIEW @ REAR FITTING ROOM ENTRANCE SCALE: N.T.S. 4' -0" FINISHED DRYWALL OPENING 3) PLAN VIEW @ FLOOR FITTING ROOM ENTRANCE SCALE: N.T.S. TENANT G.C. SHALL REPAINT INSIDE CORNER OF SHEET ROCK BLACK TO MATCH BLACK REVEAL (TYP) 1/2' X 1/4' BLACK REVEAL 3/4' BLOCKING TO BE LAMINATED PL -1 ON ALL (4) SIDES. FITTING ROOM ENTRANCES DETAILS TRIM CAP' SCALE: N.T.S. ENTRANCE TO REAR AREA FiTTiNG ROOMS iS TO BE UNCASED FROM FLOOR TO CELINiG. TAN ROPE AND PLATE SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.C. (TYPICAL BOTH SiDES) NOTES LEGEND EXISTING CONCRETE BLOCK WALL C 2 EXISTING PARTITION TO BE REMOVED ELEVATION NUMBER LETTER REFERENCE DRAWING NO. L PREFABRICATED MILLWORK (INSTALLED BY TENANT G.C.) USE GROUP: M (MERCANTILE) OCCUPANT LOAD: 203 PEOPLE 630 S.F. STOCKROOM = 2 P 6,049 SF SALES AREA = 201 P) 5/8' SHEET ROCK 3 -5/8" METAL STUD 1 1" MOLDING TRIM CAP 6'X6° WALL PLATE SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.C. (TYPICAL BOTH SiDES) Q 2 INSIDE FRAME OF ENTRYWAY SCALE: N.T.S. REAR FITTING ROOM ENTRYWAY TENANT G.C. SHALL FURNISH AND INSTALL THE FOLLOWING REST ROOM ACCESSORIES: - MIRROR, #6293, 18 "X3O ", SURFACE MOUNTED - PAPER TOWEL DISPENSER, POLDER 5341 -47, SURFACE MOUNTED - WASTE RECEPTACLE, BOBRiCK B -3644 WALL MOUNTED (MOUNT PER MANUFACTURER'S SPECS) 2) IT 15 THE TENANT G.C.'S RESPONSIBILITY TO RECEIVE ALL DRESS BARN SUPPLIED MATERIALS AND TO CHECK ORDERS FOR COMPLETENESS AND ACCURACY AGAINST VENDOR LiST AND DRESS BARN DRAWING SPECIFICATIONS AS WELL AS ANY DAMAGE AT THE TiME OF ARRIVAL- CONTRACTOR WiLL BEAR THE COST FOR ANY DAMAGE OR LOSS TO MILLWORK, LIGHTING, ETC. THAT iS NOT REPORTED AT THE TiME OF DELIVERY. 3) VERIFY LAYOUT AND ALL DIMENSIONS PRiOR TO THE CONSTRUCTION OF ANY WALLS AND REPORT ANY DISCREPANCIES TO THE DRESS BARN PROJECT MANAGER IMMEDIATELY. 1/4" HiLT1 TOGGLER BOLT WiTH PHILIPS FLAT HEAD SCREWS SHOULD BE USED ON ALL STANDARDS. 4) NO BLOCK OR MASONRY WALL OR TEXTURED FiNiSH ACCEPTED WiTHOUT WRITTEN APPROVAL OF DRESS BARN. 5) ANY WORK DENOTED AS "BY LANDLORD" SHALL BE FILED UNDER SEPARATE PERMIT BY LANDLORD AND SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PRiOR TO DRESS BARN'S CONTRACTOR COMMENCING WORK.. 6) INTERIOR WALL- AND CEILING FINISH SHALL HAVE A FLAME SPREAD RATING NO GREATER THAN CLASS C, 76 -200. MAXIMUM SMOKE DEVELOPED 0 -450. ■ NEW PARTITION 20 GAUGE 3 -5/8' SHEET METAL STUDS 16' O.C. WITH 5/8° SHEET ROCK ON BOTH SIDES (SEE DETAIL 2 ON SHEET 3) (BY TENANT G.C.) EXISTING PARTITION TO REMAIN (BY LANDLORD) FOR DEMISING WALLS AND FiRE RATED WALLS SEE DETAIL 4 DRAWING A1.1. FOR INTERIOR PARTITIONS SEE DETAIL 1 DRAWING A1.1. NEW PARTITION 20 GAUGE 3 -5/8' SHEET METAL STUDS 16' O.C. TO BE FIRE RATED WITH 5/8' SHEET ROCK ON BOTH SIDES. TIGHT TO DECK ABOVE AND TO BE CAULKED AT THE FLOOR AND DECK BY LANDLORD IF REQUIRED BASE BUILDING EXTERIOR WALL TO BE BUILT OUT WITH 5/8' TYPE 'X' GYPSUM BOARD ON 2 -1/2' MIN. METAL STUDS WITH A MINIMUM OF R11 INSULATION BY LANDLORD. (SEE DETAIL 3 DRAWING AM) FiRE EXTINGUISHER 10 -LB, MULTIPURPOSE DRY - CHEMICAL (CLASS EX A, B, C) TO BE MOUNTED 3' -0" ABOVE FINISHED FLOOR WHERE SHOWN OR DIRECTED BY LOCAL FIRE MARSHALL H.V.A.C. SYSTEM BY LANDLORD ON SEPARATE PERMIT. SPRINKLER SYSTEM BY LANDLORD ON SEPARATE PERMIT. PLUMBING BY LANDLORD ON SEPARATE PERMIT. FIRE ALARM SYSTEM BY LANDLORD ON SEPARATEPERMIt CEP 1 9 ?nu' EH ■ • • MI THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER. NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. U a) 0 Seal: Job No: TUKWILA, WA Date: Scale: Drawn: Checked: df ED ECT DAVID . UDKOW STATE OF WASHIN+;TOIN Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614-3385 bus (480) 614 -0209 fax 3408 JULY 2, 2007 1 /8 " =1' -0" SB /EO /WS Of: DAU 12 • • • / I \ 7/13/07 REVISE SIGN HEIGHT (EO) • 8/15/07 BLDING DEPT COMMENTS (E0) A 9/6/07 BLDING DEPT COMMENTS (EO) FLOOR PLAN u a il Z-0" .2' -0" 2' -O PREF UNIT 1 �8" u 2' -0" Z -0" „6 :--o" 2' -O" 2' -O" 2' -0" 2' PREFABRICATED UNIT -2' 2" 2" 2" 3" 12" 2' -O" 12" 12" 2' -0" 2' -O" 12" ,12" 2' -O" 12' 2' -0° N 0 2 0 2'_O" 2' -0° 2' -0" 2' 2' -O' 2' -0" 2' -0" 2' -O" 2' -O" .4 1/2" 9 i I I rn 2'-O" NE 2'_O" 2 -0 NE 2 -O El u ° 3° 3 2'-0" 2' -0" 2' -0' 2' -O" l - �1r111 • 'v) 2' -0" 2' -O" 5' -9" 3' -3" 3' -O" 11" 2' -O' 2' -0" 2' -0" 2' -O" .2'- 3' -5° 1' -4 2° 2" 2 -0" PREFABRICATED UNI 2" 2" 2' -O r1,_611 ^ 2' -O" O 2' -O" 2' -O" 2' -0 PREFABRICATED UNIT 17' -3" U) L 0 I c) N r rn i I• 9' 9 34 ' - REVIEWED F0 q --- "ODE COMPLIANCE APPROVED SEP 2 4 2007 City Of Tukwila ILDIN ©IVISIC u CVV ED SEP 12 2007 t, .. • U. U v_ 0 L O 9750 NORTH 96th STREET SUITE 219 SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614-0209 fax THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. CA Z • Q W a G� Cld Q • Q Z Z 12d0 <ZZ V • W Cd LIU CO V.0 tin W Z = cra CA imm W timji � Q ® imm CI) ad 0 z P le Q z W I Seal: Date: Scale: Drawn: Checked: Revisions: DAVt) A. (.10:40W STATE OF W'AS: Ott GTON Job No: TUKWILA, WA Sheet: z J 0 • • • JULY 2, 2007 1/8"- SB /EO /WS DAU /' \ 7/13/07 REVISE SIGN HEIGHT (EO) /2\ 8/15/07 BLDING DEPT COMMENTS (EO) /o\ 9/6/07 BLDING DEPT COMMENTS (EO) Of: 12 O 6 1 cN C c 0 p FOLDABLE HANDICAP EXTENSION (2O "X3O ") Z U- 0 PERMANENT ROOM IDENTIFICATION SIGN. II I/ /I / I N / / / I / / / / / I FOLDABLE HANDICAP EXTENSION (2O °X30 ") N.T.S. / /I / / /I V RJ -11 PHONE JACK INSTALLED BY OTHERS (Y) TOILET ROOM IDENTIFICATION SYMBOL. FiLE DRAWER FiLE DRAWER 4 SIGN q. SIGN a DOOR I DOOR TOILET ROOM DOOR SIGN N.T.S. BY LANDLORD IF REQUIRED N TOILET ROOM DETAILS ADJUSTABLE CHROME HANGBAR TO HAVE RELEASE BUTTON ON TOP. 4/4° REVEAL N CASH DRAW HANGERS 1/4" REVEAL -1/4" HiNGED DOOR GARBAGE( CONTAINS ADJUSTABLE CHROME HANGBAR TO HAY RELEASE BUTTON ON TOP. FRAMING AS REQUIRED TO SUPPORT LATCHES AT TOP AND BOTTOM OF DOOR (TYP) LJ L� KENSTAN K -17 CAM LOCK (TYP) LOCKED DOOR HINGED DOOR 1' -10" 1/4" THICK 12" D1A. CIRCLE OF BACK PAINTED ACRYLIC MATTE PINISH. USE MANUFACTUERERS STANDARD BLUE 6 WHiTE COLORS. 4' 0" 4' 0" 1/4" THICK 12" EQUILATERAL TRIANGLE OF BACK PAINTED ACRYLIC, MATTE FINISH. FOR UNISEX RESTROOMS SUPERIMPOSE TRIANGLE ON CiRCLE. HiNGED DOOR OPEN 0 9 cC B AGS LOCKED DRAWER BAGS BAGS COMPU B AGS O FRONT BAR BACK ELEVATION NOTE_ ALL SHELVES TO BE FiXED IN PLACE. 1r-8" HINGED DOOR 1 GRAIN DIRECTION N.T.S. 1/4° REVEAL HANGERS 1/4" REVEAL HINGED DOOR �I EA CASH DRAW -1 ) It 4' it 12' -1O" FRONT BAR FRONT ELEVATION `-9 9- OPEN BACK BAR ELEVATION 3 -BAY CASH WRAP ELEVATIONS TOILET ROOM WALL SIGN N.T.S. BY LANDLORD IF REQUIRED TOILET ROOM NOTES BY LANDLORD @ WATER CLOSET: AMERICAN STANDARD CADET Il NO. 2216.143 ELONGATED BOWL, 18" HIGH W1TH NO. 5324.019 SEAT ® LAVATORY: BY LANDLORD AMERICAN STANDARD COMRADE OR EQUAL NO. .0124.131 FOR CONCEALED ARMS WiTH NO. 7490.472H AMARiL1S FAUCET ALL TOILET ROOM ACCESSORIES SHALL BE MANUFACTURED BY BOBRICK OR APPROVED EQUAL UNLESS OTHERWISE NOTED. O TOILET PAPER HOLDER, #B -685 SURFACE MOUNTED BY LANDLORD Q PAPER TOWEL DISPENSER POLDER 5311 -47, SURFACE MOUNTED BY LANDLORD O MiRROR, # B -293, 18 "X3O ", SURFACE MOUNTED BY LANDLORD ® SOAP DiSH, #13-972, SURFACE MOUNTED BY LANDLORD Q GRAB BARS, #B -55O7 SERIES, 36" MOUNTED ON WALL BY LANDLORD 42" GRAB BAR MOUNTED ON SiDE WALL BY LANDLORD :GARBAGE( 4' 0" 12' -1O" '12' -10" I=f 2 DRAWER - )1/4" BAGS DRAWER t'RONT N ■ I = LOCKED DRAWER BAGS BAGS COMPUTER BAGS HINGED DOOR 3/16" THICK BACK PANTED ACRYLIC MATTE FiNISH, 1/4" RADIUSED EDGES. 4/4' REVEAL OPEN CASH DRAW HANGERS 1/4" REVEAL -( I HINGED POOR 1 r_ 6 " HiNGED DOOR "UNISEX" - TEXT RAISED 1/32" MiN. 6 3/4" HiGH, WiDTH-TO- HEIGHT RATiO OF 3 :5 TO 1:1 AND STROKE WIDTH -TO- HEIGHT RATiO OF 1:5 TO 1 "10. GRADE 2 BRAILLE W/ DOTS 1/1O" D.C. IN EACH CELL, 2/10 SPACE BETWEEN CELLS, AND DOTS SHALL BE RAISED 1/4O" MIN. USE MANUFACTURERS STANDARD BLUE 6 WHiTE COLORS GARBAGE' CONTAINS 4 ' O" 4' Orr 1/4" IFE/EAL-1 GRAIN DIRECTION 1/4" REVEAL BAGS (1 O LOCKED DRAWER BAGS BAGS COMPUTER 1/4' REVEAL HINGED DOOR _J 1/2X4/2X2" DOOR STOP (TYP) LOCKED DOOR 1 GRAIN DIRECTION O WASTE RECEPTACLE, #BOBRiCK B- 3644, WALL MOUNTED (MOUNT PER MANUFACTURERS SPECS) BY TENANT G.C. BAGS 5 " 5 "-, / ADJUSTABLE CHROME � HANGBAR TO HAVE RELEASE BUTTON ON TOP. ADJUSTABLE CHROME HANGBAR TO HAVE RELEASE BUTTON ON TOP. LOCKED FiLE DRAWER 11_311 LOCKED FILE DRAWER r L 0 N 0 N O O 2"X4" METAL STUD HANDICAP EXTENSION (20 "X30 ") ` HANDICAP EXTENSION \ (20•X30 °) \ i 0 PLAN VIEW cC N 12' -1O" 3/8" PLYWOOD BACKER BEHIND ENTIRE WALL. 5/8" G.B. (TYP), TAPE E SPACKLE READY FOR PAINT. 1/4" HILTi TOGGLER BOLT BY TENANT G.G. SECTION @ PUCK N.T.S. J PUCK SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.G. LANDLORD CONTRACTOR TO PROVIDE FIREBLOCKiNG iN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES. AT THE CEILING AND FLOOR LEVELS AND AT 10' -O• INTERVALS BOTH VERTICAL AND HORIZONTAL. NOTE: 1/4" MAX. RiSE AND 1:2 MAX. SLOP OF THE TAPER RAMP. SECTION @ THRESHOLD N.T.S. EXISTING DECKING CONTINUOUS CAULK JOiNT /FIRE SAFiNG TO DECK ABOVE TOP TRACK (SAME REQUIREMENTS AS BOTTOM TRACK) SECURE 6" METAL TRACK TO DECK ABOVE 20 GAUGE (MIN) 6 "X1 -1/4" LEGS, 3/8" ROLLED BACK RETURNS METAL STUDS AT 16' -0" O.C. MAX. ONE (1) PLY 5/8" THICK, 4' WiDE TYPE "X" GYP. BD. BOTH SIDES ATTACHED TO SLAB 6 FLOOR /TOP TRACKS WiTH 4" LONG, TYPE "S" SELF TAPPING SCREWS SPREAD 8" O.C. ALONG EDGES OF BOARD AND 12" O.G. IN THE FIELD OR THE BOARD. JOiNT ORIENTED VERTICALLY 6 STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. GYP. BD. TO BE FINISHED WiTH JOiNT TAPE 6 COMPOUND AS FOLLOWS: ViNYL, DRY OR PREMIXED JOiNT COMPOUNDS, APPLIED IN TWO COATS TO JOINTS 6 SCREW HEADS, PAPER TAPE, 2" WiDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS. GYP. BD. TO RUN FROM FLOOR SLAB. FLOOR TRACK - MIN. 22 GA. 6" WIDE X 1 -1/4" - LEG ATTACHED TO SLAB WiTH POWER ACTUATED FASTENER @ 16" O.C. MAX. CONTINUOUS CAULK JOINT AT FLOOR (BOTH SIDES - TYP) PARTITION - SEE DETAIL "A" FOR PENETRATIONS N.T.S. - ONE HOUR RATED - U.L. DESIGN NO. U465 BY LANDLORD IF REQUIRED N Ar771, /i rr /f %i! /12'-0" N.T.S. A ONE (1) HOUR FIRE RATED PARTITION N.T.S. VERTICAL COMPRESSION STRUT, TYP. CROSS RUNNER #12 GA. SPLAY W1RE BRACING IN PLANE OF EA. RUNNER VERT. ANGLE 45 HEAVY DUTY MAiN RUNNER 24 GA. NOTE: DETAIL PER MC STANDARDS DOW CORNING PIRESTOP SEALANT 2000 - MN. 1' DEPTH OVER MINERAL WOOL WiTH 1/4" CROWN AROUND THE CIRCUMFERENCE OF PENETRATING ITEMS (TYPICAL BOTH SiDES) 4 WiRES EACH POINT, SEE ABOVE. TYPICAL LAYOUT STEEL STUDS PIPE OR CONDUIT MIN. 4" MINERAL WOOL U.L. PENETRATION DETAIL FOR NOTE: COMPRESSION POST SiZE ACCORDING TO THE FOLLOWING TABLE EMT 1/2" 3/4" SiZE MAX HEIGHT 4 1- 0 " 5' -2" 6 8 , - 9 1_ 11 " #12 GA. WiRE AT EACH CORNER OF LiGHT FiXTURE, TYP (CONNECT TO STRUCTURE ABOVE) WiRE MAY BE SLACK 5/8° SHEET ROCK LIGHT FIXTURE SUPPORT CEILING SEISMIC RESTRAINT /LIGHT SUPPORT DETAIL CODE COMPLIANCE APPROV SE' 2 A 201 City Of Tuna 4 ; ggi�pp SEP 12 2007 f .; 1 . , ; L' u 6 ER • • 0 0 Seal: Job No: Date: Scale: Drawn: Checked: Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614-3385 bus (480) 614 -0209 fax MI Z 00 La 07 ■o o < < z gG p• ci) Lu imm z Z Lid 1•1•1 Z 00 O� W n OC = N z Z I- L U I STATE ly e:: �; ION 3gOb TUKWILA, WA JULY 2, 2007 1 / " = 1' - 0" SB /E0 /WS Of: DAU 12 • • • ENNIIMIMMININmEmil THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.0 -. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. / I \ 7/13/07 REVISE SIGN HEIGHT (EO) A 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (ED) ADDITIONAL FIXTURES FOR. ALTERNATIVE USE: WOMAN: e s 0 , 411 0 I % `._ . I F4 57 -Wi i I I L L F4-S7 -W F4 i -Wi i F4 -5744 i -Wi -lg L MISSES: 4 I D r- - 1L r 1 i ____ l e - -7 r - - -- --1 0 r - - -- -, T r11-11-11-1 L1 r - - -- T I L -1 L -1 L -1 1 I I i 1 I I I F4 -57-Mi L F4-ST-21j i F45T-Mi i F4-57-M] L., � F4 -8T -M I r4 - 5T41 FIXTURE LEGEND W1 W3 W4 W5 W6 W2 W7 VIP bait W8 U ACCESSORY FIXTURES F21 P5 -M I I 11 II II IrP4 J P1 1 ' P3 I I F4 -ST T- TOMBSTONE CABINET FEATURE WALL (1) 71 "X113" FL -1 SHELF (3) 47 "X13" PL -1 SHELF (1) 55 "X51" LARGE FRAME (1) 8 "X8" LOGO CHOP JEWELRY TOWER GIFT TABLE (42 ") WATCH TABLE (30 ") "BETTER" JEWELRY TABLE TALL ETAGERE SOCK SPINNER ACCESSORY STRAIGHT HOSIERY FIXTURE SALES WOODEN FIXTURES WARDROBE FIXTURE MERCHANDISER WOOD STRAIGHT RACK NESTED TABLE SET (TALL TABLE, SMALL TABLE Et RISER) ROUNDER TOP (30 ") SALES CHROME FIXTURES FOUR -WAY ROUNDER F8 -ST L - ❑ T -STAND H -RACK TOTAL AMOUNT 4 0 O 2 2 2 TOTAL AMOUNT 8 4 4 8 20 TOTAL AMOUNT 30 20 50 .4 II 1r II BUMP OUT FEATURE WALL (1) 71"X13" PL -1 SHELF (3) 47 "X13" PL -1 SHELF (1) 55 "X51" LARGE FRAME ( I) 5 "X8" LOGO CHOP L 0 CQ f) 1i Ii SMALL BUMP OUT FEATURE WALL (•i) 71 "X13" PL -1 SHELF (1) 55 "X51" LARGE FRAME (1) 8 "X8" LOGO CHOP MIRROR WALL UNIT ACCESSORY WALL CABINET (4) 5O "X13" FL -1 SHELF (8) 27 "X13" PL -1 SHELF ('I) 45 "X33" M FRAME (1) 8 "X8" LOGO CHOP _I - .1�.: 1 . MUU z� xi :4517011.1 ' �� Stmere 1I 1I • s�•�■ l., - liummyr .41§1. VirriVall ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■■ ■ ■■ ■ ■ ■ ■■ r�r 1�� ■■ 11•••••••• ■ ■■ ■ ■�■ ■■ • ■•• ■■ L.I ■ ■ ■■ ■■■ ■ ■ . 13 (�1 F4 -ST -M I I i 1 F4 -5T 4.11 i F4ti5T F4 -57 -W se 35 Attie ramp "I'M NEM Eram NM k FRONT PRESENTATION PUCK WALL VARIES t 33" I- �+ 18 L V HULTI TOGGL-ERS WITH MACHINE SCREWS TO HANG FRAME. SMALL FRAME ON FITTING ROOM WALL (1) 33 "X39" SMALL FRAME ( SEP 12 2007 C 4 EB NOTE: A MAXIMUM OF TEN ('10) FRAMES (LARGE - 55 "X51") ARE SUPPLIED TO EACH STORE • • DAVID A. U9 ARCHITECT TENANT IMPROVEMENTS CONSULTING <0 THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER. NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D_A -U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. z o0 CO Q W Cig Q z • 1 : 4 0 <.z �' z W � 6Yz tin V) W Z = c/a qtr ❑ a 0 Lf z < z W U O EL Seal: Job No: Date: Scale: Drawn: Checked: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614 -0209 fax Revisions: A 7/13/07 REVISE SIGN HEIGHT (EO) 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (EO) Sheet: 5 U- O I— w TUKWILA, WA JULY 2, 2007 1/8"=1'-0" SB /EO /WS Of: DAU 12 • • • • III •111111•1111111111111111111111111•1111 . 1 .LH 4A I n0 —r�Y Ai] 1 I, 4:116) I r i 110 Ad' I I CI . °1 9 11 I∎ �I .O-.9 2 ii.,. I r; i ___ I _ . 1 .LH 4A I n0 —r�Y Ai] 1 I, 4:116) I r i 110 Ad' I I CI . °1 9 11 I∎ �I .O-.9 2 ii.,. I r; i ___ . 1 .LH ® a n0 —r�Y Ai] m ® 4:116) I r i 110 Ad' . 1 .LH - I r i 110 Ad' . °1 9 11 I∎ �I .O-.9 2 1 r; i ___ . 1 .LH - z! . °1 9 11 I∎ �I .O-.9 MI MI I 111 . 1 .LH . °1 9 11 1 - .O-.9 LEFT ELEVATION REAR ELEVATION RIGHT ELEVATION REAR EXTERIOR DISPLAY WALL ACCESSORIES FRONT ELEVATION 3LATWALL LEFT INT. WINDOW DISPLAY WALL C C 0 REAR ELEVATION NOTE: VERT EDGES TO POLISHED 1 -1/2" BULLNOSE TRIM FURNISHED BY DRESS BARN INSTALLED AND PAINTED PT-2 BY TENANT G.C. AT 11' -0" A.F.F. RIGHT CENTER WALL ELEVATION LEFT EXT. WINDOW DISPLAY WALL LANDLORD MUST PROVIDE CONTINUOUS 12" 20 GUAGE METAL STRAPPING 2' -0" O.C. STARTING AT 3' -9" A.F.F. AT PUCK LOCATION. (TYPICAL) SEE ELEVATION E ON SHEET 6 REAR ELEVATION RIGHT INT. WINDOW DISPLAY WALL RIGHT CENTER WALL ELEVATION LEFT CENTER WALL ELEVATION REAR ELEVATION N N // // INTERIOR STOREFRONT ELEVATION � /// / 0 /// 9-. // / TR MCAP RIGHT EXT. WINDOW DISPLAY WALL ( /A LT CNTR WALL ELEV. TRMCAP /7 / / % TRIMCAP TRRat / / // 419 RIGHT CENTER WALL ELEVATION REAR ELEVATION S -- /// // , / /r / /// / /// } LEFT CENTER WALL ELEVATION SCALE: NONE 9 E0 0 N TYPICAL STANDARD LAYOUT NOTE PL-I FIXTURE PANEL TO BE SUPPLIED BY MILLWORK COMPANY AND INSTALLED BY TENANT GxC, PUCK SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.C. 0 4 9' -6 (MI Cift0 9 .■■■. 4 ,■■■, ■.... mom= ENTRANCE ELEVATION ENTRY SALES AREA FITTING ROOM STOCK ROOM TOILET 12" PL -1 VALANCE SUPPLIED BY MILLWORK COMPANY AND INSTALLED BY TENANT G.C. 8 "X8" GRAPHIC LOGO SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.C. APPLY CLEAR SILICONE EVENLY ACROSS ENTIRE BACK OF CHOP. BLOWUP OF CHOP @ FEATURE WALLS SCALE: NONE FEATURE CABINETS, ACCESSORY CABINET AND, IF APPLICABLE, SHOE DEPARTMENT AND MIRRORS ROOM FINISH LEGEND ROOM FLOOR BASE WALL CEILING 1/4' 'J' MOULD T -'1, FC -3, CT--1 FC -1, FC -2, T -1 CT -1 FC -2 FC -4 FC -4 ALL DOORS /FRAMES AND EXPOSED STEEL COLUMNS TO BE PAINTED WITH A SEMI -GLOSS FINISH. NOTE: SEE SHEET FL -I FOR FLOOR FINISH SPECIFICATIONS. RROR VERTICAL GES TO BE POLISHED LT CNTR WALL ELEV. SEP 12 ZOO7 E VB -I VB -I VB -1 VB -1 EGGSHELL PT -1 SEMI -GLOSS PT -1 SEMI -GLOSS PT -1 SEMI -GLOSS PT -1 PAINT: PT -1 BENJAMIN MOORE READY -MIX COLORS "SUPER WHITE" -NO SUBSTITUTES- PT-2 BENJAMIN MOORE READY -MIX COLORS COLOR *: 1093 VINYL BASE: VB -I JOHNSONITE VINYL WALL BASE 1/8" *80 (FAWN) FOUNTAIN HEAD: FORMICA "BLACK MATRIX" #324 1/2" THICK SOLID SURFACE ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE DRY WALL NOTES 1) TENANT G.C. SHALL PAINT WALL STANDARDS TO MATCH WALL F1N1SH. DRESS BARN WILL SUPPLY STANDARDS PRE - PRIMED WHITE. 2) TENANT G.C. SHALL INSTALL BRACKETS AND SHELVES FOR ALL DISPLAY FIXTURES AS SHOWN ON THE ELEVATIONS. DO NOT SECURE/ FASTEN SHELF BRACKETS TO SHELVES. 3) NO MILLWORK SHALL BE FACE NAILED. 4) ALL DOORS /FRAMES AND EXPOSED STEEL COLUMNS TO BE PAINTED WITH A SEMI -GLOSS FINISH. 5) 1/4" DIA. HiLTI TOGGLER BOLT WITH PHILIPS FLAT HEAD SCREWS SHOULD BE USED ON ALL WALL STANDARDS. 6) ANY WORK DENOTED AS "BY LANDLORD' SHALL BE FILED UNDER SEPARATE PERMIT BY LANDLORD AND SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PRIOR TO DRESS BARN'S CONTRACTOR COMMENCING WORK. WALL FINISH LEGEND CORNER GUARDS: ARDEN ARCHITECTURAL 2 "X 2 "X 8' W -CG -V2 "MOONLIGHT" LAMINATES: PL -1 NEVAMAR "GOLDEN AN1GRE" #WAOOOI E" PL -2 NEVAMAR "CHALK WHITE" * S -7O24T PL -3 NEVAMAR (TEXTURED) "NATURAL ALLUSION" *AL --2 -1T FIT. RM. METAL TRIM: OMEGA HB FULLER IF2457M (WRINKLE/ FLAT) SIGNAGE: SEE SHEET #7 TENANT TO SUPPLY SiGNAGE WHICH SHALL CONSIST OF A MINIMUM OF THREE SIGNS WITH INDIVIDUAL CHANNEL LETTERS. FACES AND INTERNAL ILLUMINATION TO BE RED, IF CONTRASTING WITH STOREFRONT COLOR. "DRESS BARN" SIGN TO BE A MINIMUM OF 3' -5" IN HEIGHT. LETTERS SHALL BE NEW LOGO STYLE AND MOUNTED DIRECTLY TO THE FASCIA OF THE PREMISES. EXTERIOR SIGNS WILL MEET ALL LOCAL CODE REQUIREMENTS. LANDLORD TO PROVIDE PROPER BACKER AND ACCESS TO ELECTRICAL CONNECTIONS. CHARGEBACKS WILL BE MADE TO LANDLORD IF SPECIAL REQUIREMENTS ARE NEEDED TO INSTALL SIGNS. STORE FRONT: SEE SHEET #7 LANDLORD SHALL PROVIDE: SPECIAL ELEVATION FOR SIGNAGE. NEW STOREFRONT TO BE FULL HEIGHT AND WIDTH GLAZING (NO KNEEWALL). ENTRANCE SHALL BE LOCATED IN ACCORDANCE WITH TENANT'S PLANS AND SPECIFICATIONS. DOOR LOCKS MUST HAVE BEST OR FALCON HARDWARE. WINDOW TINTING TO BE APPROVED BY DRESS BARN PRIOR TO INSTALLATION. U Iv 0 a Date: Scale: Drawn: DAVID A. UD-<o ARCHITECT TENANT IMPROVEMENTS CONSULTING Checked: Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614-0209 fax THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U. _ ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. V co co R ui 7 < > < < z V1 W (.7 cel W maW u ti) W = t/1 up, W N� W a oG � v o 3 1%ifi y - v) Seal: .f3 IS" FRE DAVID A. IJDk j STATE OF WAS HiNG i ON Job No: TUK WILA, WA JULY 2, 2007 1 /8 " =1' -0" SB /EO /WS 7/13/07 REVISE SIGN HEIGHT (LO) 8/15/07 BLDING DEPT COMMENTS (E0) A 9/6/07 BLDING DEPT COMMENTS (E0) Of: 1 ai H l � DAU • w • • • ELEVATIONS 1 1111111111 1 111111111 // // --L- DRESS BARN LEASE AREA 7 EXTERIOR STOREFRONT ELEVATION SIGNAGE 78 SQ. FT. EXTERIOR STOREFRONT ELEVATION REAR EXTERIOR STOREFRONT PLAN 73' -9" 70' -11" DRESS BARN LEASE AREA 5-11" 7 / / 59' -2" Imo 7 // 59'_2" DRESS BARN LEASE AREA 73'-9" DRESS BARN LEASE AREA 25' -2" SOUTHCENTER SQUARE TUKWILA, WA 70' -11" DRESS BARN LEASE AREA 7// DRESS BARN LEASE AREA /// NEW SIGNAGE - BY DRESS BARN SIGN COLOR (NO RACEWAY) FASCIA COLOR RED *2415 ILLUMINATED SIGN WITH RED TRIM CAPS LIGHT COLOR AND BLACK RETURNS. THE SIGN VENDOR IS RESPONSIBLE FOR OBTAINING THE SIGNAGE PERMIT AND SHALL NOT FABRICATE S1GNAGE UNTIL SHOP DRAWINGS ARE APPROVED BY BOTH DRESS BARN AND THE LANDLORD AS WELL AS ALL LOCAL MUNICIPAL AUTHORITIES. THE SIGN VENDOR 15 RESPONSIBLE FOR FASCIA COLOR VERIFICATION PRIOR TO FABRICATION OF SIGNAGE. /// NEW STORE FRONT BY !LANDLORD SIGN DRAWN: 6/14/07 SIGN REVISED: 7/12/07 Ir A mom_ ; - rj A 1111111111111111111111 f-7.7 11 . 1 11 11111111IIIII • FA rAvm w r. EWA FA 1111111111111111111111 M11 1111111111 rff EWA IIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIu mmmummimm �r1�IwR� �1 h I I1,I Illllli 1111111111111111111111 .1111111111111111111 111 1111111111111111111111111111111111111111 0 // w SEP 12 ZOO] • SIGNAGE: TENANT TO SUPPLY SIGNAGE WHICH SHALL CONSIST OF A MINIMUM OF THREE SIGNS WITH INDIVIDUAL— CHANNEL LETTERS. FACES AND INTERNAL ILLUMINATION TO BE RED, IF CONTRASTING WITH STOREFRONT COLOR. "DRESS BARN" SIGN TO BE A MINIMUM OF 3' -5" IN HEIGHT. LETTERS SHALL BE NEW LOGO STYLE AND MOUNTED DIRECTLY TO THE FASCIA OF THE PREMISES. EXTERIOR SIGNS 1A/ILL- MEET ALL LOCAL CODE REQUIREMENTS. LANDLORD TO PROVIDE PROPER BACKER AND ACCESS TO ELECTRICAL CONNECTIONS. CHARGEBACKS WILL BE MADE TO LANDLORD IF SPECIAL REQUIREMENTS ARE NEEDED TO INSTALL SIGNS. STORE FRONT: LANDLORD SHALL PROVIDE: SPECIAL ELEVATION FOR SIGNAGE. NEW STOREFRONT TO BE FULL HEIGHT AND WIDTH GLAZING (NO KNEEWALL). ENTRANCE SHALL BE LOCATED IN ACCORDANCE WITH TENANT'S PLANS AND SPECIFICATIONS. DOOR LOCKS MUST HAVE BEST OR FALCON HARDWARE. WINDOW TINTING TO BE APPROVED BY DRESS BARN PRIOR TO INSTALLATION. ■■ DAVID A. U3 ARCHITECT TENANT IMPROVEMENTS CONSULTING <0 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614-3385 bus (480) 614-0209 fax THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER. NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. Cl1 z co CO a Q w > cg pQ z z . Le cj W („ - -V 'At . W � W z 0® u �W Cn� W = c= >W HQ 1.1.1 L 0 . v, — o z Id Q z U Q] O d Seal: Job No: Date: Scale: Drawn: Checked: Revisions: Sheet: 340 • . ARC HI 11 yi AVID A. LIDKOW STATE OF W'ASH(PYGTON • W s • • TUKWILA, WA JULY 2, 2007 1 /8 " =1' -0" SB /EO /WS Of: DAU , \ 7/13/07 REVISE SIGN HEIGHT (EO) A 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (EO) 2 FC -2 O FC -2 NE= MIMI. TYPICAL FITTING ROOM SiDE PANEL .. -. -- TYPICAL FITTING ROOM REAR PANEL [ I ZT CARPET REAR F/R BENCH SiDE Yew CARPET FC -2 H.G. REAR F/R BENCH SiDE VIEW CARPETED BENCH VIEW SCALE: NONE CARPET :2 BENCH REAR. F/R TOP ViEW J�� H.C. REAR F/R BENCH TOP ViEW NOTE: CARPET ON BENCHES TO BE FASTENED USiNG CARPET ADHESIVE AND 1/2" STAPLES AROUND PERIMETER (NO V1SABLE STAPLES) TENANT G.C. SHALL ADHERE CARPET TO WALL ABOVE PANEL. TENANT G.C. TO FURNISH AND INSTALL "J" CHANNEL AT UNFINISHED EDGE OF CARPET. ---■ TYPICAL CENTER FITTING ROOM WALL CARPET DETAIL SCALE: NONE NOTE: TH1S ONLY APPLIES TO SALES AREA FIT1NG ROOMS, AND NOT REAR AREA FiTTiNG ROOMS. FC -2 CARPET ABOVE FITTING ROO PANELS TO CEILING TYPICAL CENTER FITTING ROOM WALL CARPET PLAN SCALE: NONE CARPET SHAW CARPET ADHESIVE (SEE NOTE 8 FOR SPECIFICATIONS) SEAM SHAW SEAM SEALER - (SEE NOTE 9 FOR. SPECIFICATIONS) 2 CARPET SEAM DETAIL SCALE: NONE FLOOR CARPET SHAW CARPET ADHESIVE (SEE NOTE 8 FOR SPECIFICATIONS) NOTE: THiS MAT LiES OVER THE TiLE. NO WORK REQUIRED CERAMIC TILE MOULDING FOR A CERAMIC TOOL COMPANY MILWAUKEE WI. 1 -800- 236 -5230 CTC CARPET TRiM ANODIZED ALUMINUM 7/16 "X7/16" DEPTH OF MOULDING TO HAVE SAME FiNiSH HEIGHT AS TiLE a SETTING MATERIAL FLOORING DETAIL SCALE: NONE METAL TRANSiTION STRIP LL LL LL LLLLL LLL LL LL LLLL LLLLLLLLLLLLLLLL L L LLLLLLL LLL L LL LL LLLLL LLLLLLLLLLLLLL LLLLLLLLLLLLLL. CARPET TO SE TUCKED UNDER METAL E FLOOR LiNE THINSET L- FLASH AS REQUIRED TO MORTOR BED. ACHIEVE SAME FINISH HEIGHT (TYP.) 116'9" SPECIAL NOTES: 1. TENANT G.C. SHALL ADVISE DRESS BARN'S PROJECT MANAGER AS TO THE LOCATION OF ALL CONCRETE SLAB CONTROL AND EXPANSION JOINTS WITHIN THE FiRST TWO WEEKS OF CONSTRUCTION. 2. TENANT G.C. SHALL INSTALL PREFABRICATED EXPANSION JOINTS, SUPPLIED BY DRESS BARN, IN ALL HF -1 AREAS. LOCATIONS SHALL BE COORDINATED WiTH THE DRESS BARN PROJECT MANAGER PRIOR TO INSTALLATION. LLLLLL LL LLL LL LLL LL LL LLLLLLLLLLLLLLLLLLLLLLLLLLLLLL LLLLLL LL LLL LLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLLLLLLL LL LL L LLL LLLL L LL LL L LLLLLLLLLLLLLLLLLLLLLLLLLLL LL LLLLLLLI_LLLLLLLLLLLL LLLL4.L4LL LLLLLLLLLLLLLLLLLL LLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLLLLLLLL 4 4, 4 4 4 4' 4 4 0 4 4 4 04 SCALE: NONE 4 4 4 EXPANSION JOiNT DETAIL PREFABRICATED CAULK JOINT DXJ 38 BRONZE FINISH EXPANSION JOINT W/ COLONIAL TAN SEALANT MANUFACTURED BY CERAMIC TOOL COMPANY. SUPPLIED BY DRESS BARN 1/4" CERAMIC TILE. CERAMIC TILE FLOOR TO BE FINISHED FLUSH TO TOP EDGE OF EXPANSION JOINT. 1/8" THiNSET MORTAR BED EXISTING BUILDING CONCRETE SLAB EXISTING CONCRETE SLAB EXPANSION JC1NT/ CONTROL JOINT ROOM FINISH LEGEND ROOM FLOOR BASE WALL CEILING ENTRY SALES AREA FITTING ROOM STOCK ROOM � TOILET 2' -r /I■■ 1 �4 -9 • 1 1 1 1t im •:: T • PDT a riiI : -I ■. ■ ■I1■■ 1 :dlsrz■ ■ ■■ • • RTRIM.6.�M !1 9 ZL edi i il I i l 113 1 ���i,�.eMM■ ■� • F:m.ur imsmomm ■■ gii • 1 2'- ' '1 ■ ■ � 4 ' -5 " 1 70 1111 I 1_l.l_l1 1 : ' . I� • 12' -5" 81' -11" SEE NOTE 3 86' -10" 68' -4' SEE NOTE 3 116' -11" 'PEE FC -1 FC -1 16' -1" 15' -2" 44-10" SEP 12 2007 T -1, FC -3, CT -'1 FC -1, FC -2, T -1 CT -1 FC -2 FC -4 FC -4 VB -1 VB VB VB -1 EGGSHELL PT--1 SEM1 -GLOSS PT -1 SEM1 -GLOSS PT -1 SEMi -GLOSS PT -1 ACOUSTICAL CEILING TiLE ACOUSTICAL CE1L1NG TiLE ACOUSTICAL CEILING T1LE ACOUSTICAL CEILING T1LE DRY WALL ALL DOORS /FRAMES AND EXPOSED STEEL COLUMNS TO BE PAINTED WiTH A SEMI -GLOSS FINISH. NOTES 1) ANY WORK DENOTED AS BY LANDLORD" SHALL BE FILED UNDER SEPARATE PERMIT BY LANDLORD AND SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PRiOR TO DRESS BARN'S CONTRACTOR COMMENCING WORK. 2) TENANT G.C. TO INSTALL FC -5, SURFACE MOUNTED ANTi- FATIGUE MAT OVER FINISHED FC -1 FLOORING BEHIND CASHWRAP DESK. 3) TENANT G.C. SHALL SEAL CERAMIC TILE GROUT WiTH "TILE LAB" GROUT SEALER OR EQUAL. 4) TENANT G.C. SHALL FURNISH ALL LABOR AND MATERIALS TO STRIP AND POLISH ALL FC -4 FLOORING. 5) TEN •'' - 0 FURNi A 1 -T • L ARDEX Pr -• • D ARDEX CONCR - V L - AYMENT FOR ALL (HF -1 CENTiVA) F ► ` ' • 'CATIONS. UNDERLAYM 1 - - - ED IN CE W1TH MANUFACTURERS DIRECTIONS. 6) TENANT G.C. SHALL BROOM SWEEP FLOOR CLEAN. ALL HOLES, CRACKS AND DEPRESSIONS TO BE FLASH PATCHED PRIOR TO CARPET INSTALLATION. 7) FC -1 IS A DIRECTIONAL CARPET WHICH IS MANUFACTURED AND SHIPPED IN ROLLS THAT COME IN SEQUENTIAL ORDER. CARPET ROLLS MUST BE INSTALLED IN THE ROLL ORDER ON THE SHIPPING TICKET, PLEASE CONTACT DRESS BARN PROJECT MANAGER IF YOU HAVE ANY QUESTIONS. 8) CARPET ADHESIVE SPECIFICATIONS: SHAW 1-1-1000 MULTi- PURPOSE ADHESIVE, TAYLOR 2055, MAPE1 PREMIUM MULTi- PURPOSE OR APPROVED EQUIVALENT. 9) SEAM SEALER SPECIFICATIONS: SHAW H -4000 SEAM ADHESIVE, TAYLOR LATEX SEAM SEALER., MAPS LATEX SEAM SEALER OR APPROVED EQUIVALENT. .10) TENANT G.C. 15 RESPONSIBLE FOR UNLOADING OF ALL DRESS BARN SUPPLIED MATERIALS. IT 1S THE TENANT G.C. S RESPONSIBILITY TO NOTIFY DRESS BARN OF ANY DAMAGE OR DISCREPANCY IN SPECIFICATION OF MATER1AL SUPPLIED AND THAT 15 DELIVERED TO JOB SITE. CONCRETE SLAB LANDLORD SHALL PROVIDE: CEMENT FLOOR THROUGHOUT, SMOOTH FiNiSH READY FOR FLOOR COVERING. LANDLORD TO PROVIDE CONCRETE SLAB WITH A MOISTURE EMISSION LEVEL NOT TO EXCEED 5 LBS. AND PH LEVEL NOT TO EXCEED 8 THROUGHOUT TENANT'S SPACE. LANDLORD SHALL PROVIDE TENANT W1T1-1 CALCIUM CHLORIDE AND PH TESTS FROM A CERTIFIED TESTING AGENCY PRIOR TO TENANT'S POSSESSION OF SPACE. IF NOT R BY POSSESSION DATE OR IF TEST EXCEEDS STANDARDS, LANDLORD WiLL REIMBURSE TENANT FOR FLOOR PREPARATION REQUIRED TO ACHIEVE PROPER FLOOR CONDITION FOR TENANT FINISHES. FLOOR COVERING LEGEND FLOORING SOURCE FC-1 SHAW STYLE: #1875L COLOR: DRESS BARN CUSTOM COLOR NOTE: ADHESIVE AND SEAM SEALER BY TENANT G.C. DRESS BARN (845) 369 -4500 FC -2 CYPRESS POiNT V 30 STYLE: OLD SPAR COLOR: 43910 NOTE: ADHESIVE AND SEAM SEAL-ER BY TENANT G.C. DRESS BARN (845) 369 -4500 FC-3 MATS INC. FORTUS MAT COLOR: #61 EDGING COLOR: CTA-80-A (FAWN) MATS INC. (800) 628 -7462 EXT. 241 FC-4 IMPERIAL- 51839 "FORTRESS WHiTE' NOTE: TiLE AND ADHESIVE BY TENANT G.C. FC-5 BERBER EZE 3' -11" X 12' -9" WITH BLACK EDGES ON 4 SIDES COLOR: LIGHT BEiGE #19 T -1 STORE FLOORS STYLE: PETRANOVA 12 "X12" COLOR: LAVENDER GROUT: LATICRETE #61- PARCHMENT (11) ARMSTRONG COMMERCIAL FLOORING MATSiNC (800) 628 -7462 EXT: 241 T -1 STORE FLOORS STYLE: PETRANOVA 12 "X12" COLOR: LAVENDER GROUT: LATICRETE #61- PARCHMENT (11) BY TENANT G.G. DRESS BARN (845) 369 -4500 CT -1 CERAMIC TOOL COMPANY - CARPET TRiM ANODIZED ALUMINUM - MODEL# CTC 716 DB 7/16" X 7/16" TENANT G.C. CONTACT: SUSAN DOLATA 800- 236 -5230 X -337 EJ -1 CERAMIC TOOL COMPANY - EXPANSION JOINT MODEL# DXJ 716 CT- BRONZE DRESS BARN (845) 369 -4500 VB -1 JOHNSONiTE VINYL WALL BASE 1/8 #80 (FAWN) TENANT G.C. TOTAL TILE FLOORING SQ. FOOTAGE TOTAL -SQ. -FEET 1098 DAVID A. U ARCHITECT TENANT IMPROVEMENTS CONSULTING D <CD 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614 -0209 fax THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER. NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. ,A,, �sI z o0 W Q W , p Z z . eg o � " . z � z r OD W �W Z can tn I WV LLI� ~� O (, D O a im 1mm �.. v , r i Z < Z `` U 0.) 0 0 Seal: 1 3408 REGISED R �) LIB � AVID A. UDKOW 1. STATE OF WASHINGTON Job No: Date: Scale: Drawn: Checked: Revisions: / 1 7/13/07 REVISE SIGN HEIGHT (EO) /A\ 8/15/07 BLDING DEPT COMMENTS (EO) / 1 9/6/07 BLDING DEPT COMMENTS (EO) Sheet: TUKWILA, WA JULY 2, 2007 1 /8 " =1' -0" SB /EO /WS Of: 9 1 DAU • w • • NE= MIMI. CARPET REAR F/R BENCH SiDE Yew CARPET FC -2 H.G. REAR F/R BENCH SiDE VIEW CARPETED BENCH VIEW SCALE: NONE CARPET :2 BENCH REAR. F/R TOP ViEW J�� H.C. REAR F/R BENCH TOP ViEW NOTE: CARPET ON BENCHES TO BE FASTENED USiNG CARPET ADHESIVE AND 1/2" STAPLES AROUND PERIMETER (NO V1SABLE STAPLES) TENANT G.C. SHALL ADHERE CARPET TO WALL ABOVE PANEL. TENANT G.C. TO FURNISH AND INSTALL "J" CHANNEL AT UNFINISHED EDGE OF CARPET. ---■ TYPICAL CENTER FITTING ROOM WALL CARPET DETAIL SCALE: NONE NOTE: TH1S ONLY APPLIES TO SALES AREA FIT1NG ROOMS, AND NOT REAR AREA FiTTiNG ROOMS. FC -2 CARPET ABOVE FITTING ROO PANELS TO CEILING TYPICAL CENTER FITTING ROOM WALL CARPET PLAN SCALE: NONE CARPET SHAW CARPET ADHESIVE (SEE NOTE 8 FOR SPECIFICATIONS) SEAM SHAW SEAM SEALER - (SEE NOTE 9 FOR. SPECIFICATIONS) 2 CARPET SEAM DETAIL SCALE: NONE FLOOR CARPET SHAW CARPET ADHESIVE (SEE NOTE 8 FOR SPECIFICATIONS) NOTE: THiS MAT LiES OVER THE TiLE. NO WORK REQUIRED CERAMIC TILE MOULDING FOR A CERAMIC TOOL COMPANY MILWAUKEE WI. 1 -800- 236 -5230 CTC CARPET TRiM ANODIZED ALUMINUM 7/16 "X7/16" DEPTH OF MOULDING TO HAVE SAME FiNiSH HEIGHT AS TiLE a SETTING MATERIAL FLOORING DETAIL SCALE: NONE METAL TRANSiTION STRIP LL LL LL LLLLL LLL LL LL LLLL LLLLLLLLLLLLLLLL L L LLLLLLL LLL L LL LL LLLLL LLLLLLLLLLLLLL LLLLLLLLLLLLLL. CARPET TO SE TUCKED UNDER METAL E FLOOR LiNE THINSET L- FLASH AS REQUIRED TO MORTOR BED. ACHIEVE SAME FINISH HEIGHT (TYP.) 116'9" SPECIAL NOTES: 1. TENANT G.C. SHALL ADVISE DRESS BARN'S PROJECT MANAGER AS TO THE LOCATION OF ALL CONCRETE SLAB CONTROL AND EXPANSION JOINTS WITHIN THE FiRST TWO WEEKS OF CONSTRUCTION. 2. TENANT G.C. SHALL INSTALL PREFABRICATED EXPANSION JOINTS, SUPPLIED BY DRESS BARN, IN ALL HF -1 AREAS. LOCATIONS SHALL BE COORDINATED WiTH THE DRESS BARN PROJECT MANAGER PRIOR TO INSTALLATION. LLLLLL LL LLL LL LLL LL LL LLLLLLLLLLLLLLLLLLLLLLLLLLLLLL LLLLLL LL LLL LLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLLLLLLL LL LL L LLL LLLL L LL LL L LLLLLLLLLLLLLLLLLLLLLLLLLLL LL LLLLLLLI_LLLLLLLLLLLL LLLL4.L4LL LLLLLLLLLLLLLLLLLL LLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLLLLLLLL 4 4, 4 4 4 4' 4 4 0 4 4 4 04 SCALE: NONE 4 4 4 EXPANSION JOiNT DETAIL PREFABRICATED CAULK JOINT DXJ 38 BRONZE FINISH EXPANSION JOINT W/ COLONIAL TAN SEALANT MANUFACTURED BY CERAMIC TOOL COMPANY. SUPPLIED BY DRESS BARN 1/4" CERAMIC TILE. CERAMIC TILE FLOOR TO BE FINISHED FLUSH TO TOP EDGE OF EXPANSION JOINT. 1/8" THiNSET MORTAR BED EXISTING BUILDING CONCRETE SLAB EXISTING CONCRETE SLAB EXPANSION JC1NT/ CONTROL JOINT ROOM FINISH LEGEND ROOM FLOOR BASE WALL CEILING ENTRY SALES AREA FITTING ROOM STOCK ROOM � TOILET 2' -r /I■■ 1 �4 -9 • 1 1 1 1t im •:: T • PDT a riiI : -I ■. ■ ■I1■■ 1 :dlsrz■ ■ ■■ • • RTRIM.6.�M !1 9 ZL edi i il I i l 113 1 ���i,�.eMM■ ■� • F:m.ur imsmomm ■■ gii • 1 2'- ' '1 ■ ■ � 4 ' -5 " 1 70 1111 I 1_l.l_l1 1 : ' . I� • 12' -5" 81' -11" SEE NOTE 3 86' -10" 68' -4' SEE NOTE 3 116' -11" 'PEE FC -1 FC -1 16' -1" 15' -2" 44-10" SEP 12 2007 T -1, FC -3, CT -'1 FC -1, FC -2, T -1 CT -1 FC -2 FC -4 FC -4 VB -1 VB VB VB -1 EGGSHELL PT--1 SEM1 -GLOSS PT -1 SEM1 -GLOSS PT -1 SEMi -GLOSS PT -1 ACOUSTICAL CEILING TiLE ACOUSTICAL CE1L1NG TiLE ACOUSTICAL CEILING T1LE ACOUSTICAL CEILING T1LE DRY WALL ALL DOORS /FRAMES AND EXPOSED STEEL COLUMNS TO BE PAINTED WiTH A SEMI -GLOSS FINISH. NOTES 1) ANY WORK DENOTED AS BY LANDLORD" SHALL BE FILED UNDER SEPARATE PERMIT BY LANDLORD AND SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PRiOR TO DRESS BARN'S CONTRACTOR COMMENCING WORK. 2) TENANT G.C. TO INSTALL FC -5, SURFACE MOUNTED ANTi- FATIGUE MAT OVER FINISHED FC -1 FLOORING BEHIND CASHWRAP DESK. 3) TENANT G.C. SHALL SEAL CERAMIC TILE GROUT WiTH "TILE LAB" GROUT SEALER OR EQUAL. 4) TENANT G.C. SHALL FURNISH ALL LABOR AND MATERIALS TO STRIP AND POLISH ALL FC -4 FLOORING. 5) TEN •'' - 0 FURNi A 1 -T • L ARDEX Pr -• • D ARDEX CONCR - V L - AYMENT FOR ALL (HF -1 CENTiVA) F ► ` ' • 'CATIONS. UNDERLAYM 1 - - - ED IN CE W1TH MANUFACTURERS DIRECTIONS. 6) TENANT G.C. SHALL BROOM SWEEP FLOOR CLEAN. ALL HOLES, CRACKS AND DEPRESSIONS TO BE FLASH PATCHED PRIOR TO CARPET INSTALLATION. 7) FC -1 IS A DIRECTIONAL CARPET WHICH IS MANUFACTURED AND SHIPPED IN ROLLS THAT COME IN SEQUENTIAL ORDER. CARPET ROLLS MUST BE INSTALLED IN THE ROLL ORDER ON THE SHIPPING TICKET, PLEASE CONTACT DRESS BARN PROJECT MANAGER IF YOU HAVE ANY QUESTIONS. 8) CARPET ADHESIVE SPECIFICATIONS: SHAW 1-1-1000 MULTi- PURPOSE ADHESIVE, TAYLOR 2055, MAPE1 PREMIUM MULTi- PURPOSE OR APPROVED EQUIVALENT. 9) SEAM SEALER SPECIFICATIONS: SHAW H -4000 SEAM ADHESIVE, TAYLOR LATEX SEAM SEALER., MAPS LATEX SEAM SEALER OR APPROVED EQUIVALENT. .10) TENANT G.C. 15 RESPONSIBLE FOR UNLOADING OF ALL DRESS BARN SUPPLIED MATERIALS. IT 1S THE TENANT G.C. S RESPONSIBILITY TO NOTIFY DRESS BARN OF ANY DAMAGE OR DISCREPANCY IN SPECIFICATION OF MATER1AL SUPPLIED AND THAT 15 DELIVERED TO JOB SITE. CONCRETE SLAB LANDLORD SHALL PROVIDE: CEMENT FLOOR THROUGHOUT, SMOOTH FiNiSH READY FOR FLOOR COVERING. LANDLORD TO PROVIDE CONCRETE SLAB WITH A MOISTURE EMISSION LEVEL NOT TO EXCEED 5 LBS. AND PH LEVEL NOT TO EXCEED 8 THROUGHOUT TENANT'S SPACE. LANDLORD SHALL PROVIDE TENANT W1T1-1 CALCIUM CHLORIDE AND PH TESTS FROM A CERTIFIED TESTING AGENCY PRIOR TO TENANT'S POSSESSION OF SPACE. IF NOT R BY POSSESSION DATE OR IF TEST EXCEEDS STANDARDS, LANDLORD WiLL REIMBURSE TENANT FOR FLOOR PREPARATION REQUIRED TO ACHIEVE PROPER FLOOR CONDITION FOR TENANT FINISHES. FLOOR COVERING LEGEND FLOORING SOURCE FC-1 SHAW STYLE: #1875L COLOR: DRESS BARN CUSTOM COLOR NOTE: ADHESIVE AND SEAM SEALER BY TENANT G.C. DRESS BARN (845) 369 -4500 FC -2 CYPRESS POiNT V 30 STYLE: OLD SPAR COLOR: 43910 NOTE: ADHESIVE AND SEAM SEAL-ER BY TENANT G.C. DRESS BARN (845) 369 -4500 FC-3 MATS INC. FORTUS MAT COLOR: #61 EDGING COLOR: CTA-80-A (FAWN) MATS INC. (800) 628 -7462 EXT. 241 FC-4 IMPERIAL- 51839 "FORTRESS WHiTE' NOTE: TiLE AND ADHESIVE BY TENANT G.C. FC-5 BERBER EZE 3' -11" X 12' -9" WITH BLACK EDGES ON 4 SIDES COLOR: LIGHT BEiGE #19 T -1 STORE FLOORS STYLE: PETRANOVA 12 "X12" COLOR: LAVENDER GROUT: LATICRETE #61- PARCHMENT (11) ARMSTRONG COMMERCIAL FLOORING MATSiNC (800) 628 -7462 EXT: 241 T -1 STORE FLOORS STYLE: PETRANOVA 12 "X12" COLOR: LAVENDER GROUT: LATICRETE #61- PARCHMENT (11) BY TENANT G.G. DRESS BARN (845) 369 -4500 CT -1 CERAMIC TOOL COMPANY - CARPET TRiM ANODIZED ALUMINUM - MODEL# CTC 716 DB 7/16" X 7/16" TENANT G.C. CONTACT: SUSAN DOLATA 800- 236 -5230 X -337 EJ -1 CERAMIC TOOL COMPANY - EXPANSION JOINT MODEL# DXJ 716 CT- BRONZE DRESS BARN (845) 369 -4500 VB -1 JOHNSONiTE VINYL WALL BASE 1/8 #80 (FAWN) TENANT G.C. TOTAL TILE FLOORING SQ. FOOTAGE TOTAL -SQ. -FEET 1098 DAVID A. U ARCHITECT TENANT IMPROVEMENTS CONSULTING D <CD 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614 -0209 fax THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER. NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. ,A,, �sI z o0 W Q W , p Z z . eg o � " . z � z r OD W �W Z can tn I WV LLI� ~� O (, D O a im 1mm �.. v , r i Z < Z `` U 0.) 0 0 Seal: 1 3408 REGISED R �) LIB � AVID A. UDKOW 1. STATE OF WASHINGTON Job No: Date: Scale: Drawn: Checked: Revisions: / 1 7/13/07 REVISE SIGN HEIGHT (EO) /A\ 8/15/07 BLDING DEPT COMMENTS (EO) / 1 9/6/07 BLDING DEPT COMMENTS (EO) Sheet: TUKWILA, WA JULY 2, 2007 1 /8 " =1' -0" SB /EO /WS Of: 9 1 DAU • w • • 0) 0 cn 8' -9" r 0 OPEN OPEN 0 B 0 o CASHWRAP MURAL DETAIL SCALE: NONE BRANDING MURAL SIGN SUPPLIED BY DRESS BARN DB 2c09 DB 2009 • DOORS WITHOUT PADDLE HANDLES DOOR DECAL DETAIL SCALE: NONE DOOR WITH HORIZONTAL PUSH BAR DOOR WITHOUT HORIZONTAL PUSH BAR DOORS WITH PADDLE HANDLES DB 2 009 NOTES 1) FOR 2010/ 2011 SEE FL -1 FOR INSTALLATION INSTRUCTION NOTES. 2) TENANT G.C. TO INSTALL ALL DECALS AND GRAPHICS SUPPLIED BY DRESS BARN PER THIS PLAN. 3) TENANT G.C. TO INSTALL DRESS BARN SUPPLIED GRAND OPENING DECALS ON ALL STOREFRONT GLASS. 4) STOREFRONT DECAL 2009 1S A STATIC CLING DECAL FOR GRAND OPENING. DECALS SHALL BE REMOVED BY STORE PERSONNEL ONE MONTH AFTER GRAND OPENING. 5) FOR SIGNAGE INSTALLATION SEE DETAIL SHEET D -4. 6) DB 2012 SHOULD BE INSTALLED USING CLEAR SILICONE APPLIED EVENLY ACROSS ENTIRE BACK OF CHOP. SIGN LEGEND DB.2001 DB.2002 DB.2003 DB.2004 DB.2005 DE; .2006 DB.20C8 DB.200 9 DB.2010 DB.20'1'f DB_2O12 DB.20'(3 DB.20'(4 DB.2015 DB.2016 DB.20'f7 DB.20'(8 DB.2019 HANGING MISSES SIGN HANGING WOMAN SIGN HANGING PETITE SIGN FITTING ROOM SLIDE -1N SIGN - SEE DETAIL SHEET D -4 DRESS BARN WALL SIGN (12') WOMAN WALL SIGN (8 ") DRESS BARN DOOR DECAL GRAND OPENING DECAL INLAY FLOOR CHOP (32 ") INLAY FLOOR CHOP (48') MISSES PUCKWALL SIGN WOMAN PUCKWALL SIGN LAMINATED CHOP (8 "X8 ") SIZES 4 -24 DOOR DECAL WOMAN SIZES 14-24 DOOR DECAL BRANDING MURAL - 8' -6" X 3' -4" CEILING HUNG BRANDING MURAL - 8' -6" X 3'--4" WALL MOUNTED BRANDING MURAL - 10' -0' X 4' -O "" WALL MOUNTED SEP 12 2007 • • DAVID A. U3KO ARCHITECT TENANT IMPROVEMENTS CONSULTING U d] O o_ Seal: Date: Scale: Drawn: Checked: Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614-0209 fax Q z r W Q >C e Q < z Z O v W i tit) 1-1- r <.z L I L0 U_ IN 1 1:1m I mm 4 ;I: ri z 1,e < z W 1 z mei 1. z CHITEC7' D' Vii) A. UL',r,() j STATE OF WAS1 3408 JULY 2, 2007 1/8"=V-0" SB /EO /WS Of: DAU 1 • w • • • THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. Job No: TUKWILA, WA /' \ 7/13/07 REVISE SIGN HEIGHT (EO) 2\ 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (EO) / -9 3/4" 1' -9 3/4" � 1 d��31, d raq @baTw I 09111 .17i1 z �i(E35 4 -24 Ed�aM 4534 0� ®4 4� 1' -4 3/" / sozem 4 =24 / / • Z ft I 1' -4 3/4'1 / / 0) 0 cn 8' -9" r 0 OPEN OPEN 0 B 0 o CASHWRAP MURAL DETAIL SCALE: NONE BRANDING MURAL SIGN SUPPLIED BY DRESS BARN DB 2c09 DB 2009 • DOORS WITHOUT PADDLE HANDLES DOOR DECAL DETAIL SCALE: NONE DOOR WITH HORIZONTAL PUSH BAR DOOR WITHOUT HORIZONTAL PUSH BAR DOORS WITH PADDLE HANDLES DB 2 009 NOTES 1) FOR 2010/ 2011 SEE FL -1 FOR INSTALLATION INSTRUCTION NOTES. 2) TENANT G.C. TO INSTALL ALL DECALS AND GRAPHICS SUPPLIED BY DRESS BARN PER THIS PLAN. 3) TENANT G.C. TO INSTALL DRESS BARN SUPPLIED GRAND OPENING DECALS ON ALL STOREFRONT GLASS. 4) STOREFRONT DECAL 2009 1S A STATIC CLING DECAL FOR GRAND OPENING. DECALS SHALL BE REMOVED BY STORE PERSONNEL ONE MONTH AFTER GRAND OPENING. 5) FOR SIGNAGE INSTALLATION SEE DETAIL SHEET D -4. 6) DB 2012 SHOULD BE INSTALLED USING CLEAR SILICONE APPLIED EVENLY ACROSS ENTIRE BACK OF CHOP. SIGN LEGEND DB.2001 DB.2002 DB.2003 DB.2004 DB.2005 DE; .2006 DB.20C8 DB.200 9 DB.2010 DB.20'1'f DB_2O12 DB.20'(3 DB.20'(4 DB.2015 DB.2016 DB.20'f7 DB.20'(8 DB.2019 HANGING MISSES SIGN HANGING WOMAN SIGN HANGING PETITE SIGN FITTING ROOM SLIDE -1N SIGN - SEE DETAIL SHEET D -4 DRESS BARN WALL SIGN (12') WOMAN WALL SIGN (8 ") DRESS BARN DOOR DECAL GRAND OPENING DECAL INLAY FLOOR CHOP (32 ") INLAY FLOOR CHOP (48') MISSES PUCKWALL SIGN WOMAN PUCKWALL SIGN LAMINATED CHOP (8 "X8 ") SIZES 4 -24 DOOR DECAL WOMAN SIZES 14-24 DOOR DECAL BRANDING MURAL - 8' -6" X 3' -4" CEILING HUNG BRANDING MURAL - 8' -6" X 3'--4" WALL MOUNTED BRANDING MURAL - 10' -0' X 4' -O "" WALL MOUNTED SEP 12 2007 • • DAVID A. U3KO ARCHITECT TENANT IMPROVEMENTS CONSULTING U d] O o_ Seal: Date: Scale: Drawn: Checked: Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614-0209 fax Q z r W Q >C e Q < z Z O v W i tit) 1-1- r <.z L I L0 U_ IN 1 1:1m I mm 4 ;I: ri z 1,e < z W 1 z mei 1. z CHITEC7' D' Vii) A. UL',r,() j STATE OF WAS1 3408 JULY 2, 2007 1/8"=V-0" SB /EO /WS Of: DAU 1 • w • • • THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. Job No: TUKWILA, WA /' \ 7/13/07 REVISE SIGN HEIGHT (EO) 2\ 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (EO) / -9 3/4" / CI r(D2.0 b) ELM dF@EZI5EF I 09111 .17i1 z �i(E35 4 -24 0� ®4 4� 1' -4 3/" / / I / 0) 0 cn 8' -9" r 0 OPEN OPEN 0 B 0 o CASHWRAP MURAL DETAIL SCALE: NONE BRANDING MURAL SIGN SUPPLIED BY DRESS BARN DB 2c09 DB 2009 • DOORS WITHOUT PADDLE HANDLES DOOR DECAL DETAIL SCALE: NONE DOOR WITH HORIZONTAL PUSH BAR DOOR WITHOUT HORIZONTAL PUSH BAR DOORS WITH PADDLE HANDLES DB 2 009 NOTES 1) FOR 2010/ 2011 SEE FL -1 FOR INSTALLATION INSTRUCTION NOTES. 2) TENANT G.C. TO INSTALL ALL DECALS AND GRAPHICS SUPPLIED BY DRESS BARN PER THIS PLAN. 3) TENANT G.C. TO INSTALL DRESS BARN SUPPLIED GRAND OPENING DECALS ON ALL STOREFRONT GLASS. 4) STOREFRONT DECAL 2009 1S A STATIC CLING DECAL FOR GRAND OPENING. DECALS SHALL BE REMOVED BY STORE PERSONNEL ONE MONTH AFTER GRAND OPENING. 5) FOR SIGNAGE INSTALLATION SEE DETAIL SHEET D -4. 6) DB 2012 SHOULD BE INSTALLED USING CLEAR SILICONE APPLIED EVENLY ACROSS ENTIRE BACK OF CHOP. SIGN LEGEND DB.2001 DB.2002 DB.2003 DB.2004 DB.2005 DE; .2006 DB.20C8 DB.200 9 DB.2010 DB.20'1'f DB_2O12 DB.20'(3 DB.20'(4 DB.2015 DB.2016 DB.20'f7 DB.20'(8 DB.2019 HANGING MISSES SIGN HANGING WOMAN SIGN HANGING PETITE SIGN FITTING ROOM SLIDE -1N SIGN - SEE DETAIL SHEET D -4 DRESS BARN WALL SIGN (12') WOMAN WALL SIGN (8 ") DRESS BARN DOOR DECAL GRAND OPENING DECAL INLAY FLOOR CHOP (32 ") INLAY FLOOR CHOP (48') MISSES PUCKWALL SIGN WOMAN PUCKWALL SIGN LAMINATED CHOP (8 "X8 ") SIZES 4 -24 DOOR DECAL WOMAN SIZES 14-24 DOOR DECAL BRANDING MURAL - 8' -6" X 3' -4" CEILING HUNG BRANDING MURAL - 8' -6" X 3'--4" WALL MOUNTED BRANDING MURAL - 10' -0' X 4' -O "" WALL MOUNTED SEP 12 2007 • • DAVID A. U3KO ARCHITECT TENANT IMPROVEMENTS CONSULTING U d] O o_ Seal: Date: Scale: Drawn: Checked: Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614-0209 fax Q z r W Q >C e Q < z Z O v W i tit) 1-1- r <.z L I L0 U_ IN 1 1:1m I mm 4 ;I: ri z 1,e < z W 1 z mei 1. z CHITEC7' D' Vii) A. UL',r,() j STATE OF WAS1 3408 JULY 2, 2007 1/8"=V-0" SB /EO /WS Of: DAU 1 • w • • • THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. Job No: TUKWILA, WA /' \ 7/13/07 REVISE SIGN HEIGHT (EO) 2\ 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (EO) NOT A■■ S A■ �::']■ I■ • ■■PI■ • • II .■ dN TRAM■ I7 MAW 1II M CMS I� eq UR' anan.g In MN M N; RN JO NM A NE' Mil Ili 114"4081614 qpi mg E. m ■ ■ ■■p■■ • � ' • • 1NO1CA I SHA HA Y! 36" C 4R4NCL. . _ SEP 12 ZOO1 • • • • v 0 Q- Seal: Job No: Date: Scale: Drawn: Checked: Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614 -0209 fax W r 34t. w';1v�' t CHITECT DAVID A. i1DK0w STATE OF }'AEh N, C I TDIV 1 Of: 1 • THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER. NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. TUKWILA, WA JULY 2, 2007 1/8"=1'-0" SB /EO /WS DAU • • • !' \ 7/13/07 REVISE SIGN HEIGHT (EO) 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (EO) ELECTRICAL SYMBOL LIST IA-CS1 PB THERMOSTAT (LIGHT STAT MODEL # TME-AVU) MOUNTED 54" A.F.F. BY LANDLORD. THERMOSTAT /DUCT HEATER MOUTED 54" A.F.F. BUZZER, MOUNTED 6° ABOVE CEILING. PUSHBUTTON. JUNCTION BOX. ' REALISTiC° 45 WATT, 8" SPEAKER # 40 -1272 WiTH SPEAKER GRILLE # 40 -4225, OR EQUAL. WiTH 70 VOLT, IOW LiNE TRANSFORMER, RADIO SHACK CAT. NO. 32 -1O31B BY OTHERS. S/P WALL SWITCH HOME RUN TO PANEL. ARROWHEAD DENOTE NUMBER OF CIRCUITS. OCCUPANCY SENSOR - STOCK ROOM AND COORiDORS ONLY LIGHTOLiER MODEL #OS -C SENSOR FURNISHED BY DRESS BARN, INSTALLED BY TENANT G.C. SENSOR TO BE SET AT 30 MiNUTE DELAY BY TENANT G.C. SENSOR SHALL BE INDEPENDENT OF LIGHTSTAT CONTROL SYSTEM LIGHTSTAT AUTOMATIC LIGHTING CONTROL SYSTEM (MODEL #ALC- 3- 44 -DRB) CONTACT: BETSY RENOUI =- 800- 292 -2444 RON EiGENBROD- 800- 292 -2444 PUSH BUTTON FOR AUTOMATIC LIGHTING CONTROL SYSTEM. LANDLORD SHALL OBTAIN FULL- AND COMPLETE WARRANTIES FOR ALL HVAC, ELECTRICAL, AND PLUMBING EQUIPMENT FROM THE CONTRACTOR PROVIDING SAiD SERVICES, WHICH WILL REMAIN iN EFFECT I YEAR AND FORWARD TO TENANT FOR ITS RECORDS. LANDLORD TO PROVIDE FULL AND FINAL UTILITIES HOOK UP, SEPARATELY METERED TO TENANT SPACE READY FOR REASSIGNMENT TO TENANT ACCOUNT PRiOR TO POSSESSION. HVAC LANDLORD TO PROVIDE: 100% NEW PACKAGED HVAC UNITS WITH INTEGRATED ECONOMIZERS WITH POWER EXHAUST FOR 100% LEASED SPACE. UNiTS SHALL BE MANUFACTURED BY CARRIER, TRANE, YORK OR APPROVED EQUAL. THERMOSTATS SHALL HAVE AUTOMATIC NIGHT SET B ACK BASED ON CHANGES IN INTERIOR LGGHT LEVEL (LIGHTSTAT MODEL TME-AVU). ALL. DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL IN ACCORDANCE WiTH SMACNA FOR LOW PRESSURE, LOW VELOCITY DUCT WORK. THE USE OF FLEXIBLE DUCTWORK SHALL BE PERMITTED ONLY FOR VERTICAL PROPS DOWN TO CEILING DIFFUSERS. INSTALLATION OF FIBERBOARD DUCTWORK iS NOT ALLOWED. 400% OF PREMISES TO BE DUCTED TO ACCOMMODATE TENANT'S ARCHITECTURAL LAYOUT AND ALL UNiTS DIRECT - DUCTED RETURN AiR SYSTEMS. ALL DUCTWORK MUST BE FULLY INSULATED. MINIMUM REQUIREMENT FOR SPACE COOLING iS 7 TON OF AiR CONDITIONING FOR EVERY 300 SQUARE FEET OF LEASED SPACE. MINIMUM REQUIREMENTS FOR SPACE HEATING SHALL BE BASED ON 70% INDOOR DESIGN TEMPERATURE USING THE 97% FREQUENCY DESIGN COLUMN FOR WINTER CONDITIONS OF THE LATEST ASHRAE GUIDE. LANDLORD WILL PROVIDE ELECTRIC DUCT HEATERS WiTH INDIVIDUAL WALL - MOUNTED THERMOSTATS FOR STOCK ROOM AND REAR AREA FITTING ROOMS. DUCT HEATERS SHALL BE 2 STAGE, AS MANUFACTURED BY 1NDEECO, MARKEL OR APPROVED EQUAL. STOCK AND FITTING ROOMS UP TO 500 SQUARE FEET IN FLOOR AREA, SHALL HAVE A MINIMUM OF 4 KW DUCT HEATERS. STOCK AND FITTiNG ROOMS OVER 500 SQUARE FEET IN FLOOR AREA, SHALL HAVE A MiNiMUM 6 KW DUCT HEATERS. DUCT HEATERS SHALL BE WIRED TO LOCKOUT WHENEVER THEIR RELATED HVAC UNiT IS IN HEATING MODE TO PREVENT SIMULTANEOUS HEATING. CEILING DIFFUSERS AND RETURN AIR REGISTERS SHALL BE MANUFACTURED BY T1TUS, ANEMOSTAT, CARNES OR APPROVED EQUAL, AND SHALL- BE EQUIPPED WiTH VOLUME DAMPERS. NO ONE DIFFUSER SHALL SUPPLY MORE THAN 600 CFM. LANDLORD SHALL PROVIDE A CERTIFIED AiR BALANCE REPORT TO DRESS BARN AT TiME OF POSSESSION. BALANCE REPORT SHALL BE PREPARED BY AN V (DEPENDENT TESTING AND BALANCING CONTRACTOR WHO iS A MEMBER OF THE AABC OR NEBB. REPORT SHALL ALSO INCLUDE THE FOLLOWING TEMPERATURE READINGS: AiR LEAVING DIFFUSERS, SIR LEAVING HVAC UNiT SALES AREA TEMPERATURE AND OUTSIDE AiR TEMPERATURE. FIRE PROTECTION /FIRE ALARMS LANDLORD TO PROVIDE: SPRINKLER SERVICE AS PER BUILDING AND LOCAL CODES IN ACCORDANCE WiTH TENANT INTERIOR DESIGN. LANDLORD MUST TAKE INTO ACCOUNT TENANT FINISHES AND TRACK LIGHTING AND 2'X4' LIGHTING IN LOCATING SPRINKLER HEADS. FiRE ALARM SYSTEM AS REQUIRED BY LOCAL CODES WORKING AS SPECIFIED BY LOCAL AUTHORITIES. H.V.A.C. BY LANDLORD ON SEPARATE PERMIT. SPRINKLER SYSTEM BY LANDLORD ON SEPARATE PERMIT. PLUMBING BY LANDLORD ON SEPARATE PERMIT. FIRE ALARM SYSTEM BY LANDLORD ON SEPARATE PERMIT. SYMBOL TYPE MANUFACTURER CATALOG NO. B 0 T4 -1 LiGHTOLIER A LiGHTOLIER F NUTONE T2 LiGHTOLIER T4 LiGHTOLIER C MERCURY G MERCURY MERCURY D(N /L) MERCURY 1102P1 FRAME KIT 1171P1 TRIM QT10OL 9276W14 ELECTRONIC BALLAST 9476WH ELECTRONIC BALLAST 9476WH ELECTRONIC BALLAST MB154T5ELB MB224HOT5ELB 35E2320CT9A- SRTELB 35E232OCT9A- SRTELB LAMPS MOUNTING (1) 60W PAR 36FL (1) BOW PAR 19FL (2) 20846 FP24830HO (2) 20857 FP54830H0 (2) 20857 FP5483OH0 (1) FP5483OH0 (2) FP2483OHO (2)F032/73O (2)F032/730 PLACE FIRST ROW OF 2'X4' "D° LiGHTS 3'O" FROM STOREFRONT (IN LINE WiTH THE DiSPLAY WALL) RECESSED RECESSED TRACK TRACK TRACK SURFACE SURFACE GRiD GRID N OTE: NO SUBSTITUTIONS TO SPECIFICATIONS WiTHOUT DRESS BARN'S WRITTEN APPROVAL. NEW RECESSED DOWN LiGHT FURNISHED BY DRESS BARN AND INSTALLED BY TENANT G.C. NEW GYPSUM BOARD CEILING BY LANDLORD TENANT G.C. SHALL PAINT PT -1 FLAT FINISH (TYP.) + 17'4' APP. TRACK LIGHTING SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.C. NEW GYPSUM BOARD PARTITION WALL BY LANDLORD REAR STORE SECTION N.T.S. REMARKS =NM r r - TENANT G.G. SHAL SUPPLY AND INSTALL (3) 2' -0' CROSS TEES 4' OFF FACE OF ENTRANCE WALL 'TO HANG POSTERS DOWN LiGHT WiTH TRIM FAN /LIGHT/NIGHT -LIGHT COMBINATION 6000 SERIES TRACK MATTE WHiTE FiNiSH TYP. 6000 SERIES TRACK MATTE WHiTE FiNiSH TYP. 6000 SERIES TRACK. CONNECT TO PHOTOCELL/ SIGN CONTACTOR WHITE FINISH NO REFLECTOR 2' MERCURY STRIP PRISMATIC LENS WITH SILVER REFLECTOR (NIGHT LIGHT) PRISMATIC LENS WITH SiLVER REFLECTOR 4 T2 2 FIXTURE SCHEDULE SYMBOL x X 4 ALL STOREFRONT PUCKWALL TRACK LIGHTING TO BE CONNECTED TO SALES AREA LIGHTING CIRCUITING. ALL OTHER STOREFRONT TRACKLiGHT1NG TO BE CONNECTED TO EXTERIOR SiGNAGE CONTACTOR — ALL STOREFRONT PUCKWALL TRACK LIGHTING TO BE CONNECTED TO SALES AREA LIGHTING CIRCUITING. ALL OTHER STOREFRONT TRACKLIGHTING TO BE CONNECTED TO EXTERIOR SiGNAGE CONTACTOR TYPE MANUFACTURER CATALOG NO. D-2 D- 2(N/L) E E-1 E -2 EM EL MERCURY MERCURY LIGHTOLiER LIGHTOLIER LIGHTOLiER LiTHONiA LITHONiA 34E2170CT9A- SRTELB 34E217OCT9A-SRTELB 9022WH 9022WH 9022WH W /MONO POiNT ADAPTER ELM2 LQMSW3R120 /277ELN 70 VOLT, 40W LiNE TRANSFORMER #32 -1O31B (TO AMPLIFIER) (TO AMPLIFIER) 'REALISTIC' 45 WATT, 8" SPEAKER #40 -4272 WITH SPEAKER GRILLE #40 -1225 (WHITE) SECONDARY SiDE (OHMS TAP) 5 e- PRIMARY SIDE (WATTS TAP) -. .62 -0 1.25 -S 2.5 SPEAKER SCHEMATIC LAMPS MOUNTING (21F017/730 (21E017/730 (1) COW CAP HALOGEN PAR 38 FL (1) BOW CAP HALOGEN PAR 38 FL (1) SOW CAP HALOGEN PAR 38 FL INCLUDED INCLUDED GRID GRID TRACK TRACK SURFACE CEILING MOUNTED NEW CEILING AT 11' -O" A.F.F. BY LANDLORD (SEE NOTE (4) FOR SPECIFICATIONS) REMARKS PRISMATIC LENS WITH SILVER REFLECTOR (NIGHT LiGHT) PRISMATIC LENS WITH SILVER REFLECTOR 6000 SERIES TRACK MATTE WHITE FINISH TYP. 6000 SERIES TRACK MATTE WHITE FINISH TYP. MONOPOINT ADAPTER FOR SURFACE MOUNTING MATTE WHITE FINISH CEILING MOUNTED MATTE WHITE FINISH NOTE USE WHERE SAGGING OCCURS IN CEILING. 2 1/2" (HOLD) NEW SHEET ROCK CEILING AT A.F.F. BY LANDLORD. LANDLORD TO FURNISH AND INSTALL ACCESS PANEL TO HOT WATER HEATER AS REQUIRED. OPEN /CLOSE PUSHBUTTON FOR LIGHTSTAT AUTOMATIC LIGHTING CONTROL SYSTEM. WALL MOUNTED BY LANDLORD. SEE NOTE #10 3 5/8' METAL STUD NEW FAN LIGHTS SUPPLIED AND INSTALLED BY LANDLORD. NEW CEILING AT 11' -O" A.F.F. BY LANDLORD (SEE NOTE (4) FOR SPECIFICATIONS) NO LIGHT TO SHINE ON CEILING ACOUSTICAL CEILING TiLE CEILING GRID 'V FIXTURE NOTE: TRACK TO BE SCREWED THRU CEILING TiLE INTO METAL STUD AS REQUIRED. SUPPORT DETAIL @ "T" FIXTURE NOTE: USE WHERE APPLICABLE WiTH COMPLIANCE TO LOCAL AND STATE CODES. NEW SHEET ROCK SOFFIT AT 10' -O" A.F.F. BY TENANT G.G. CEILING LINE 'I~ FIXTURE NEW CEILING AT 11' -O" A.F.F. BY LANDLORD (SEE NOTE (4) FOR SPECIFICATIONS) 2 1/2" (HOLD) NOTE THE LIGHT LEVEL HAS TO START FROM THE TOP OF THE WALL STANDARD. ELECTRICAL LANDLORD TO PROVIDE: WiRE, AND INSTALL THE MAiN SERVICE AT THE PREMISES. FOR LOCATIONS UTILIZING NATURAL GAS FOR SPACE HEATING, THE ELECTRICAL SERVICE SHALL BE BASED ON 12 WATTS PER SQUARE FOOT OF LEASED PREMISES. FOR LOCATIONS UTILIZING ELECTRIC HEATING COILS FOR SPACE HEATING, ELECTRIC SERVICE SHALL BE BASED ON 15 WATTS PER SQUARE FOOT OF LEASED PREMISES. ON 480/277 VOLTS SERVICE, A TRANSFORMER SHOULD BE USED TO REDUCE VOLTAGE TO 120 VOLTS FOR LIGHTING, PLUG RECEPTACLES AND SMALL POWER EQUIPMENT BASED ON OUR CONNECTED LOAD. A 3-PHASE 4 -WIRE PANEL BOX SHOULD HAVE 12 CiRCUITS FOR EACH 1000 SQUARE FEET OF ENTIRE PREMISES. LANDLORD SHALL FURNISH, INSTALL AND WiRE TENANT'S ELECTRICAL SERVICE INCLUDING ALL METERING EQUIPMENT, PANEL BOARD(S), TRANSFORMERS (IF REQUIRED) AND LIGHTSTAT AUTOMATIC LIGHTING CONTROL SYSTEM, MODEL# ALC- 3-44DRB WHERE INDICATED ON TENANT'S CONSTRUCTION DOCUMENTS. ANY FANLIGHTS AND FLUORESCENT FIXTURES WiLL BE LOCATED ACCORDING TO TENANT'S PLAN. EXiT AND EMERGENCY LIGHTS PER DRESS BARN DRAWINGS OR TO LOCAL CODE REQUIREMENTS WHICHEVER ARE GREATER. WIRED SiGN CiRCUITS WiTH CONTACTOR AND TiME CLOCK (INTERMATiC MODEL 175) FROM MAIN PANEL TO "J" BOX(ES) AT THE SIGN(S) LOCATION(S) ON THE PREMISES. ELECTRIC PANEL, CONTACTOR AND SWITCHES FOR GENERAL LIGHTING AND PHONE CONDUIT FROM TELEPHONE ROOM TO TENANT SPACE SHALL BE INSTALLED IN ACCORDANCE WITH TENANT'S PLANS AND SPECIFICATIONS. 4' -O" + - UNLESS OTHERWISE ff NOTED WALL TRACK LIGHTING LIGHTING iN THiS AREA BY LANDLORD. (BUILDING SERVICE CORRIDOR) NOT PART OF DRESS BARN SPACE. SEE LANDLORD SHELL DRAWINGS. DOOR BELL AND BUZZER BY LANDLORD. I'X5' GRID SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.C. TENANT G.C. SHALL MODIFY GRiD AS REQUIRED TO FiT DISPLAY DIMENSIONS (SEE DETAIL 6). ALL STOREFRONT PUCKWALL TRACK LIGHTING TO BE CONNECTED TO SALES AREA LIGHTING CIRCUITING. ALL OTHER STOREFRONT TRACKLIGHTING TO BE CONNECTED TO EXTERIOR SIGNAGE CONTACTOR NEW CEILING AT I1' -O" A.F.F. BY LANDLORD (SEE NOTE (4) FOR SPECIFICATIONS) LANDLORD TO MAKE SURE REAR STORE AREA IS PROPERLY VENTILATED ALL STOREFRONT PUCKWALL TRACK LIGHTING TO BE CONNECTED TO SALES AREA LIGHTING CIRCUITING. ALL OTHER STOREFRONT TRACKLIGHTING TO BE CONNECTED TO EXTERIOR SIGNAGE CONTACTOR 1'X5' GRiD SUPPLIED BY DRESS BARN AND INSTALLED BY TENANT G.C. TENANT G.C. SHALL MODIFY GRiD AS REQUIRED TO FIT DISPLAY DIMENSIONS (SEE DETAIL 6). WALL STANDARD SEP 12 2007 LIGHTING LEVEL TRACK TRACK LIGHT1NG STOREFRONT GLAZING FLOORING SCALE: NONE NOTE: STOREFRONT CEILING LiNE TRACK LIGHTING E -1 AND T -1 HEADS SHOULD NOT SHiNE ON STOREFRONT GLASS (SEE DETAIL 2 ON SHEET 10) STOREFRONT TRACK LIGHTING DETAIL THREADED EYE HOOK WiTH TOGGLER (SUPPLIED BY TENANT G.C.) W/ 'S' HOOK (SUPPLIED BY DRESS BARN). TENANT G.C. TO INSTALL ALL. CEILING LOOP (SUPPLIED BY DRESS BARN) ON CEILING GRiD W/ "S" HOOK (SUPPLIED BY DRESS BARN). TENANT G.C. TO INSTALL ALL. NON COMB 2' X 4' 4'X5' METAL GRID SUPPLIED BY TENANT HANGING 1' X 5' GRiD FROM DRYWALL CEILING NOTE: USE WHERE APPLICABLE WITH COMPLIANCE TO LOCAL ff STATE cams. CEILING GRiD WITH PROPER SUPPORT FROM STRUCTURE ABOVE 1'X5' METAL GRID SUPPLIED BY TENANT DRYWALL CEILING ACOUSTICAL CEILING TILE HANGING 1' X 5' GRiD FROM ACOUSTICAL CEILING NOTE: USE WHERE APPLICABLE WITH COMPLIANCE TO LOCAL Z£ STATE CODES. METHODS FOR HANGING 1' X 5' GRID N.T.S. CODE COMPLIANC APPRO SE' `1 2Ni Cit Of 6"ila BUILDIN NOTES 1) TENANT G.C. TO INSTALL ALL TYPE "A ", "C ", "E ", "G ", "T" AND TRACK LIGHTING PER TENANT PLAN SUPPLIED BY DRESS BARN. k. A . 1S SU' ' L s = D SS B FOR E -1 AND ALSO INSTALL (C .C. SHALL INSTALL .C. SHALL AME. 3) OCCUPANCY SENSOR (INDEPENDENT OF LIGHTSTAT CONTROL SYSTEM.) LiGHTOLiER MODEL #0S -C SENSOR FURNISHED BY DRESS BARN, INSTALLED BY TENANT G.C. SENSOR TO BE SET AT 30 MiNUTE DELAY BY TENANT G.C. 4) CEILING GRiD TO BE 2'X4' AS SHOWN WiTH ARMSTRONG CORTEGA #769 NON - DIRECTIONAL 2'X4' CEILING TiLE. (BY LANDLORD) 5) LANDLORD TO INSTALL ALL TYPE "D ", "D2 ", EXiT AND EMERGENCY LIGHTING PER TENANT PLAN. 6) FAN LiGHT SUPPLIED AND INSTALLED BY LANDLORD 7) ANY WORK DENOTED AS "BY LANDLORD" SHALL BE FILED UNDER SEPARATE PERMIT BY LANDLORD AND SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PRiOR TO DRESS BARN CONTRACTOR COMMENCING WORK. 8 ) TENANT G.C. MUST COORDINATE FINAL T -STAT LOCATION WiTH DRESSBARN PROJECT MANAGER. 9) LANDLORD SHALL COORDINATE LIGHTING CiRCUiT DESIGN/ LAYOUT WiTH LIGHTSTAT REPRESENTATIVE INDICATED ON SYMBOL LiST. 10) NOTE TO LANDLORDS ARCHITECT: PLEASE NOTE THAT WHEN SUBMITTING PRINTS TO DRESS BARN OR LIGHTSTAT THE PLANS SHOULD BE CIRCUITED AS FOLLOWS: - SALES AREA 2X4 FLOURESCENT FIXTURES WILL BE EVERY OTHER FIXTURE FOR A 50/50 CONTROL SPLIT. - STOCK ROOM AND RESTROOMS WILL BE ON THEIR OWN CIRCUIT, SEPERATED FROM THE SALES FLOOR. FORWARD A SET OF CAD PRINTS TO BRENOUF @LIGHTSTAT.COM OR PLANS@LIGHTSTAT.COM AS LIGHTSTAT COMPONENTS WILL NEED TO BE LOCATED ON THE DRAWINGS. THEY WILL THEN BE RETURNED TO YOU FOR DISTRIBUTION. • • • • • DAVID A. U ARCHITECT TENANT IMPROVEMENTS CONSULTING 3 '<o 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 - 3385 bus (480) 614 -0209 fax w • • THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. U m 0 n Seal: Job No: TUKWILA, WA Date: Scale: Drawn: Checked: Revisions: 3408 FF Gi; F7 �'CHITECT I •A A.11w "' -OW STATE OF fAS ;1OTOtd / I \ 7/13/07 REVISE SIGN HEIGHT (EO) A 8/15/07 BLDING DEPT COMMENTS (EO) A\ 9/6/07 BLDING DEPT COMMENTS (EO) Sheet: 11 JULY 2, 2007 1/8"=1'-0" SB /E0 /WS Of: DAU 12 o 0 d -- q 0 O 1 0 / l (C I ll /■ i \. . (c) ® —��. (c5) :a „0,41-0 \\ \ ` . ` �� .fib 1 I I I I I 7 1 ---- 1 l e_�co❑ o 0 d q 0 O p 0 - / I ll /■ i \. . . ` � —��. �� 1 A /\ I ,, \\ \ ` ` �� II II il 1l /l \III i �i i i\ I I 41 I 11' 1 .1,I I 1 111. Ili 1 I - -- (4) 1 CONDUITS TO FRONT WRAP (CONDUITS TO BE RUN FROM NEAREST LOCATION SHOWN ON SHEET E -2 TO FRONT WRAP) INCOMING POWER BY TENANT G.C. INCOMING PHONE LiNE BY OTHER - - - - - (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) INCOMING CAT S LINE(S) BY OTHER — — (TENANT GC SHALL- LEAVE CONDUIT EMPTY WITH PULL STRING) EMPTY (WITH PULL STRING) - - - - -- I V OUTLET TO BE MOUNTED 3' BELOW COUNTER TOP (TYP). (ALL WIRI=S ARE TO BE RUN THROUGH BACK SHROUD NOT THROUGH CABINET$) EMPTY (WITH PULL STRING) o-- - J 1 PHONE LINE TO BACK WRAP ----- BY OTHER (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) POWER TO BACK BAR - (3) 1" CONDUITS TO BACK BAR (CONDUITS TO BE RUN FROM FRONT WRAP TO BACK WRAP) SCALE: NONE r -- -POWER TO BACK BAR I- - -� PHONE LINE TO BACK WRAP BY OTHER (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) EMPTY (WITH PULL STRING) I I \� A i \ \ 2 YYY�Y ■ :: • 0 0 J r - � CLOSED II CA BI II III III II CLOS II II CABINET II II II II II o II III III III o III III II = III II 1-J 4I1 �!I nnn ME III 1I1 (3) 1" CONDUITS TO BACK BAR (CONDUITS TO BE RUN FROM FRONT WRAP TO BACK WRAP) PHONE JACK TO BE LOCATED ON REAR CABINET WALL OF BACK BAR 3' BELOW COUNTER. TENANT G.C. TO PROVIDE PULL STRING TO LOCATION. WIRE AND JACK BY OTHERS. (ALL WiRE$ TO BE RUN THROUGH BACK SHROUD NOT THROUGH CABINETS) ISLAND BACK WRAP ELEC. DETAIL N a) (' BLACK GROMMET FURNISHED AND INSTALLED BY MILLWORK CO. I I L PLAN VIEW EMPTY (WITH PULL STRING -- -J I PHONE LiNE TO BACK WRAP - -- BY OTHER (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) POWER TO BACK BAR �- (3) 1 CONDUITS TO BACK BAR (CONDUITS TO BE RUN FROM FRONT WRAP TO BACK WRAP) J TERMINATE CAT 5 CABLES AT THIS LOCATION BY OTHERS. (TYPICAL iN EACH MODULE) EMPTY (WITH PULL STRING) --� PHONE LiNE TO BACK WRAP BY OTHER (TENANT GC SHALL. LEAVE CONDUIT EMPTY WITH PULL STRING) POWER TO BACK BAR - - (3) 1" CONDUITS TO BACK BAR (CONDUITS TO BE RUN FROM FRONT WRAP TO BACK WRAP) FRONT ELEVATION SCALE: NONE J j 1 L - EMPTY (WITH PULL STRING) I L -- INCOMING CAT 5 LiNE(S) BY OTHER (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) L -- - INCOMING PHONE LINE BY OTHER (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) L — -- INCOMING POWER BY TENANT G.C. (4) 1" CONDUITS TO FRONT WRAP ( CONDUiTS TO BE RUN FROM NEAREST LOCATION SHOWN ON SHEET E -2 TO FRONT WRAP) TWO ORANGE S/C 12OV 20 AMPS I.G. RECEPTACLES PER CIRCUIT BY TENANT GC (TYPICAL IN EACH MODULE). I ' 1 '- -EMPTY (WITH PULL STRING) J I L - - INCOMING CAT 5 LINE(S) BY OTHER (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) - -- INCOMING PHONE LiNE BY OTHER (TENANT GC SHALL LEAVE CONDUIT EMPTY WITH PULL STRING) L _ _ INCOMING POWER BY TENANT G.C. (4) 1" CONDUITS TO FRONT WRAP (CONDUITS TO BE RUN FROM NEAREST LOCATION SHOWN ON SHEET E -2 TO FRONT WRAP) ISLAND FRONT WRAP ELEC. DETAIL HVAC LANDLORD TO PROVIDE: 100% NEW PACKAGED HVAC UNITS WITH INTEGRATED ECONOMIZERS WiTH POWER EXHAUST FOR 100% LEASED SPACE. UNiTS SHALL BE MANUFACTURED BY CARRIER, TRANE, YORK OR APPROVED EQUAL. THERMOSTATS SHALL HAVE AUTOMATIC NIGHT SET BACK BASED ON CHANGES IN INTERIOR LiGHT LEVEL (LIGHTSTAT MODEL TME-AVU). ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL IN ACCORDANCE WiTH SMACNA FOR LOW PRESSURE, LOW VELOCITY DUCT WORK. THE USE OF FLEXIBLE DUCTWORK SHALL BE PERMITTED ONLY FOR VERTICAL DROPS DOWN TO CEILING DIFFUSERS. INSTALLATION OF FIBERBOARD DUCTWORK IS NOT ALLOWED. 100% OF PREMISES TO BE DUCTED TO ACCOMMODATE TENANT'S ARCHITECTURAL LAYOUT AND ALL UNiTS DiRECT- DUCTED RETURN AiR SYSTEMS. ALL DUCTWORK MUST BE FULLY INSULATED. MINIMUM REQUIREMENT FOR SPACE COOLING IS 1 TON OF AIR CONDITIONING FOR EVERY 300 SQUARE FEET OF LEASED SPACE. MINIMUM REQUIREMENTS FOR SPACE HEATING SHALL BE BASED ON 70% INDOOR DESIGN TEMPERATURE USING THE 97% FREQUENCY DESIGN COLUMN FOR WINTER CONDITIONS OF THE LATEST ASHRAE GUiDE. LANDLORD WiLL PROVIDE ELECTRIC DUCT HEATERS WiTH INDIVIDUAL WALL- MOUNTED THERMOSTATS FOR STOCK ROOM AND REAR AREA FiTTiNG ROOMS. DUCT HEATERS SHALL BE 2 STAGE, AS MANUFACTURED BY INDEECO, MARKEL OR APPROVED EQUAL. STOCK AND FiTTiNG ROOMS UP TO 500 SQUARE FEET iN FLOOR AREA, SHALL HAVE A MiNiMUM OF 4 KW DUCT HEATERS. STOCK AND FiTTiNG ROOMS OVER 500 SQUARE FEET iN FLOOR AREA, SHALL HAVE A MiNiMUM 5 KW DUCT HEATERS. DUCT HEATERS SHALL BE WIRED TO LOCKOUT WHENEVER THERR RELATED HVAC UNiT IS IN HEATING MODE TO PREVENT SIMULTANEOUS HEATING. CEILING DIFFUSERS AND RETURN AIR REGISTERS SHALL BE MANUFACTURED BY TiTUS, ANEMOSTAT, CARNES OR APPROVED EQUAL, AND SHALL BE EQUIPPED WiTH VOLUME DAMPERS. NO ONE DIFFUSER SHALL SUPPLY MORE THAN 600 CFM. LANDLORD SHALL PROVIDE A CERTIFIED AiR BALANCE REPORT TO DRESS BARN AT TiME OF POSSESSION. BALANCE REPORT SHALL BE PREPARED BY AN INDEPENDENT TESTING AND BALANCING CONTRACTOR WHO 1S A MEMBER OF THE AABC OR NEBB. REPORT SHALL ALSO INCLUDE THE FOLLOWING TEMPERATURE READINGS: AIR LEAVING DIFFUSERS, AiR LEAVING HVAC UNIT SALES AREA TEMPERATURE AND OUTSIDE AiR TEMPERATURE. ELECTRICAL LANDLORD TO PROVIDE: WiRE, AND INSTALL THE MAiN SERVICE AT THE PREMISES. FOR LOCATIONS UTILIZING NATURAL GAS FOR SPACE HEATING, THE ELECTRICAL SERVICE SHALL BE BASED ON 12 WATTS PER SQUARE FOOT OF LEASED PREMISES. FOR LOCATIONS UTILIZING ELECTRIC HEATING COILS FOR SPACE HEATING, ELECTRIC SERVICE SHALL BE BASED ON 15 WATTS PER SQUARE FOOT OF LEASED PREMISES. ON 480/277 VOLTS SERVICE, A TRANSFORMER SHOULD BE USED TO REDUCE VOLTAGE TO 120 VOLTS FOR LIGHTING, PLUG RECEPTACLES AND SMALL POWER EQUIPMENT BASED ON OUR CONNECTED LOAD. A 3 -PHASE 4 -WIRE PANEL BOX SHOULD HAVE 12 CIRCUITS FOR EACH 1000 SQUARE FEET OF ENTIRE PREMISES. LANDLORD SHALL FURNISH, INSTALL AND WiRE TENANT'S ELECTRICAL SERVICE INCLUDING ALL METERING EQUIPMENT, PANEL BOARD(S), TRANSFORMERS (1F REQUIRED) AND LIGHTSTAT AUTOMATIC LIGHTING CONTROL SYSTEM, MODEL# ALC- 3-44 -DRB WHERE INDICATED ON TENANT'S CONSTRUCTION DOCUMENTS. ANY FANLIGHTS AND FLUORESCENT FIXTURES WiLL BE LOCATED ACCORDING TO TENANT'S PLAN. EXiT AND EMERGENCY LIGHTS PER DRESS BARN DRAWINGS OR TO LOCAL CODE REQUIREMENTS WHICHEVER ARE GREATER. WIRED SiGN CIRCUITS WiTH CONTACTOR AND TIME CLOCK (INTERMATIC MODEL '175) FROM MAiN PANEL TO °J' BOX(ES) AT THE S1GN(S) LOCATiON(S) ON THE PREMISES. ELECTRIC PANEL, CONTACTOR AND SWITCHES FOR GENERAL LIGHTING AND PHONE CONDUIT FROM TELEPHONE ROOM TO TENANT SPACE SHALL BE INSTALLED IN ACCORDANCE WiTH TENANT'S PLANS AND SPECIFICATIONS. LANDLORD TO PROVIDE FULL AND FINAL UTILITIES HOOK UP, SEPARATELY METERED TO TENANT SPACE READY FOR REASSIGNMENT TO TENANT ACCOUNT PRiOR TO POSSESSION. LANDLORD SHALL OBTAIN FULL AND COMPLETE WARRANTIES FOR ALL HVAC, ELECTRICAL, AND PLUMBING EQUIPMENT FROM THE CONTRACTOR PROVIDING SAID SERVICES, WHiCH WiLL REMAIN IN EFFECT 1 YEAR AND FORWARD TO TENANT FOR iTS RECORDS. LANDLORD TO PROVIDE FULL AND FINAL UTILITIES HOOK UP, SEPARATELY METERED TO TENANT SPACE READY FOR REASSIGNMENT TO TENANT ACCOUNT PRIOR TO POSSESSION. FiRE PROTECTION /FIRE ALARMS LANDLORD TO PROVIDE: SPRINKLER SERVICE AS PER BUILDING AND LOCAL CODES IN ACCORDANCE WiTH TENANT INTERIOR DESIGN. LANDLORD MUST TAKE INTO ACCOUNT TENANT FINISHES AND TRACK LIGHTING AND 2'X4' LIGHTING IN LOCATING SPRINKLER HEADS. FiRE ALARM SYSTEM AS REQUIRED BY LOCAL CODES WORKING AS SPECIFIED BY LOCAL AUTHORITIES. ® R1 ® T� T T1P E 0 T1P L. RiNG C g RiNG 0 E RJ31 PUNCHDOWN BLOCK DO NOT USE SHORTING CLIPS ON THE PAiR FOR THE RJ31X. RJ31X WIRING DIAGRAM LIGHTSTAT CHOICE (AUX) OF B OR 0 OUTPUT-I HVAC EQUIPMENT TERMINAL STRIP �Wy ® a SYSTEM TRANSFORMER I I I 1 VALUE DAMPER FAN OR RELAY COOL 4 COOL 2 l HEAT 1 I { HEAT 2 I FAN I-- LIGHTSTAT THERMOSTAT WIRING DIAGRAM SALES AREA ONLY r 1Q 1_ 0 ' JUCTiON BOX FOR EXTERIOR SiGNAGE BY LANDLORD 2 , 1 ' - DUPLEX OUTLET MOUNTED ABOVE CEILING CONNECTED TO SALES AREA TRACK LIGHTING CIRCUIT BY TENANT G.C. FOR FUTURE USE. DUPLEX OUTLET WITH A DEDICATED CIRCUIT TO BE MOUNTED ABOVE CEILING BY TENANT G.C. DUPLEX OUTLET MOUNTED ABOVE CEILING CONNECTED TO SALES AREA TRACK LIGHTING CIRCUIT BY TENANT G.C. FOR FUTURE USE. 21 -4" 14 0 21 -2 SECURITY ALARM CONTROL TENANT G.C. SHALL BOX IN PAD TO BE MOUNTED 5' -0" COLUMN AS REQUIRED TO A.P.F. BY OTHERS. ACCOMMODATE POWER AND COMMUNICATION CONDUITS. SAW CUT FOR ELECTRICAL AND COMMUNICATIONS WIRING BY TENANT G.C. 21 a r te! t • ► ) 0 to TENANT G.C. TO INSTALL (1) DEDICATED DUPLEX OUTLET ADJACENT TO TELEPHONE COMPANY V' MARK. THE RJ31X TO BE MOUNTED ABOVE THE CEILING. DUPLEX OUTLET WiTH A DEDICATED CIRCUIT TO BE MOUNTED ABOVE CEILING BY TENANT G.C. FOR ADT CONTROL PANEL. NEW MAiN ELECTRICAL SERVICE BY LANDLORD. LIGHTSTAT AUTOMATIC LIGHTING CONTROL PANEL BY LANDLORD. (COORDINATE DESIGN W/ CONTACTS ON SYMBOL LiST.) ALSO SEE NOTE 16. DOOR BELL AND BUZZER BY LANDLORD. OUTLET TO BE MOUNTED A.F.F. FOR STEREO UNiT BY LANDLORD SPEAKER WIRES TO BE TERMINATED AT STEREO OUTLET LOCATION BY OTHERS. DUPLEX OUTLET WITH A DEDICATED CIRCUIT FOR COMPUTER SERVER BY TENANT G.C. TENANT G.C. TO PROVIDE A JUNCTION BOX AND PULL STRING TO THiS LOCATION. CAT 5 GANG BOX AND WIRES BY OTHERS. ,,v1- co 0)- ,* N NOTES 1) 1T IS THE TENANT G.C.'S RESPONSIBILITY TO SUPERVISE THE INSTALLATION OF PHONE/ DATA WiRE TO ASSURE ALL JACKS AND LINES HAVE BEEN PROPERLY LOCATED. ANY CONFLICT OR DISCREPANCY SHOULD BE BROUGHT TO THE ATTENTION OF THE DRESS BARN PROJECT MANAGER FOR RESOLUTION. 2) TENANT G.G. TO PROVIDE LOCK -ONS (IF ALLOWED BY CODE) FOR THE FOLLOWING CIRCUITS: - REFRIGERATOR OUTLET (V.I.F.) - REGISTER OUTLETS - EMERGENCY LiGHTS, EXiT SIGN a NIGHT LiGHTS - TIME CLOCK -- SECURITY/ ADT - DEDICATED OUTLETS -STOCK ROOM LIGHTS - AS PER STORE REQUEST 3) TENANT G.C. TO VERIFY LOCATION AND NUMBERS FOR THE FOLLOWING METERS AND REPORT THEM TO DRESS BARN'S PROJECT MANAGER: - GAS METER - ELECTRICAL METER - WATER METER 4) TENANT G.C. SHALL INSTALL JUNCTION BOXES AT ALL WALL PHONE JACK LOCATIONS AND PROVIDE PULL STRINGS FROM BOX TO ABOVE CEILING. 5) TENANT G.C. TO INSTALL ALL OUTLETS IN WALLS BUILT BY TENANT G.C. LANDLORD TO INSTALL ALL OUTLETS IN WALLS BUILT BY LANDLORD. 6) ALL OUTLETS AND FACE PLATES TO BE WHiTE (EXCEPT WHERE NOTED). 7) TiME CLOCK TO BE (INTERMATIC T -175 OR EQUAL, SINGLE DAY TiMER, SINGLE POLE DOUBLE THROW). 8) COORDINATE THERMOSTAT LOCATIONS WiTH DRESS BARN'S PROJECT MANAGERS. (AVOID NIGHT LIGHTS) 9) ELECTRICAL CONTRACTOR TO PROVIDE TYPED ELECTRICAL PANEL DIRECTORY. 10) WHEN CONTACTORS ARE SUPPLIED BY DRESS BARN, THEY SHALL BE MECHANICALLY HELD TYPE, NOT ELECTRICALLY HELD. WALL SWITCHES CONNECTED TO CONTACTORS SHALL BE SINGLE POLE DOUBLE THROW TYPE. 11) LANDLORD'S CONTRACTOR MUST MOUNT CONTACTOR ON PLYWOOD BACKER. 12) NO MORE THAN (2) OUTLETS PER 20 AMP CiRCUIT. 13) LANDLORD'S ELECTRICAL CONTRACTOR MUST VERIFY SWITCHES AND CONTACTORS ARE COMPATIBLE PRiOR TO INSTALLATION. 14) ALL CIRCUITS, TIMER AND CONTACTOR FOR SiGN TO BE SUPPLIED AND INSTALLED BY LANDLORD. 15) ANY WORK DENOTED AS "BY LANDLORD" SHALL BE FiLED UNDER SEPARATE PERMIT BY LANDLORD AND SHALL BE COMPLETED (WITH REQUIRED INSPECTIONS) PRIOR TO DRESS BARN CONTRACTOR COMMENCING WORK. NOTE TO LANDLORDS ARCHITECT 16) PLEASE NOTE THAT WHEN SUBMITTING PRINTS TO DRESS BARN OR LIGHTSTAT THE PLANS SHOULD BE CIRCUITED AS FOLLOWS: - SALES AREA 2X4 FLOURESCENT FIXTURES WILL BE EVERY OTHER FIXTURE FOR A 50/50 CONTROL SPLIT. - STOCK ROOM AND RESTROOMS WILL BE ON THEIR OWN CIRCUIT, SEPERATED FROM THE SALES FLOOR. FORWARD A SET OF CAD PRINTS TO BRENOUF @LIGHTSTAT.COM OR PLANS @LIGHTSTAT.COM AS LIGHTSTAT COMPONENTS WILL NEED TO BE LOCATED ON THE DRAWINGS. THEY WILL THEN BE RETURNED TO YOU FOR DISTRIBUTION. ELECTRICAL SYMBOL LIST Q 4 9 gGFI V V s 0 T.c. TIME CLOCK. (INTERMATIC T -175 OR EQUAL, SiNGLE DAY TiMER, SiNGLE POLE - DOUBLE THROW) "REALISTIC' 15 WATT, 8' SPEAKER # 40 -1272 WITH SPEAKER GRILLE # 40 -1225, OR EQUAL. WITH 70 VOLT, 1OW LiNE TRANSFORMER, RADIO SHACK CAT. NO. 32 -4031B BY OTHERS. ® SECURITY ALARM CONTROL PAD BY OTHERS. 4 S/P WALL SWITCH HOME RUN TO PANEL. ARROWHEAD DENOTE NUMBER OF CIRCUITS. IALcs1 THERMOSTAT (LIGHT STAT MODEL # TME MOUNTED 54' A.F.F. BY LANDLORD. THERMOSTAT /DUCT HEATER MOUNTED 54' A.P.F. DUPLEX CONVENIENCE OUTLET, 125 VOLTS, 20 AMP. MOUNTED 16' A.F.F. OR AS NOTED. DUPLEX OUTLET, 125 VOLTS, 20 AMP. WiTH 1.G. DEDICATED CIRCUIT MOUNTED 16' A.F.F. OR AS NOTED. GROUND FAULT INTERRUPTER JUNCTION BOX. RJ11W JACK FOR DESK PHONE (LISTED #) RJ11W JACK FOR M.S.I. SYSTEM (UNLISTED #) RJ11W JACK FOR WALL PHONE MOUNTED 0 4-5' A.F.P. (LISTED #) RJ31X JACK FOR ALARM SYSTEM MOUNTED AT OR ABOVE CEILING LiNE (LISTED #) IF THERE IS NO CEILING, IT SHOULD BE INSTALLED AT 1O' -O ". BUZZER, MOUNTED 6' ABOVE CEILING. PUSHBUTTON. ® ELECTRICAL PANEL IJ L CATALOG #42777 -11A (GANG BOX) LEVITON CATALOG #41080 -4XP (FACE PLATE) MOUNTED 16' A.F.F. OR AS NOTED. LIGHTSTAT AUTOMATIC LIGHTING CONTROL SYSTEM (MODEL #ALC- 3- 44DR8) CONTACT: BETSY RENOUF- 800- 292 -2444 RON EiGENBROD- 800- 292 -2444 H.V.A.C. BY LANDLORD ON SEPARATE PERMIT. SPRINKLER SYSTEM BY LANDLORD ON SEPARATE PERMIT. PLUMBING BY LANDLORD ON SEPARATE PERMIT. FIRE ALARM SYSTEM BY LANDLORD ON SEPARATE PERMIT. SEP 12 2007 vitoi 1 11 DAVID A. U3,<0 ARCHITECT TENANT IMPROVEMENTS CONSULTING THESE DRAWINGS ARE THE INSTRUMENTS OF SERVICE AND THE PROPERTY OF D.A.U. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MATTER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT PERMISSION OF D.A.U.. ALL DIMENSIONS TO BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ANY CONSTRUCTION. r CA V rr rat Q W , Orl a Q = Z W ANO CY it ott Z z DO • WI °c ±IF C/) `u Z I Cn = O v aim ' = Q 1— N z z U 0 C- Seal: REGISTERED CHFTECT DAVID A. IMAM $TATS :s Job No: Date: Scale: Drawn: Checked: Revisions: Sheet: 11881 NORTH 113TH WAY SCOTTSDALE, AZ. 85258 (480) 614 -3385 bus (480) 614.0209 fax Of: 1- TUKWILA, WA JULY 2, 2007 1/8"—l'-0" SB /E0 /WS DAU 12 • W • • • A 7/13/07 REVISE SIGN HEIGHT (EO) A 8/15/07 BLDING DEPT COMMENTS (EO) A 9/6/07 BLDING DEPT COMMENTS (EO)