Loading...
HomeMy WebLinkAboutPermit D07-294 - MCLELAND WIESER RESIDENCE - REMODELMCI.F,T.AIVD- WIESER RES 14234 58 AV S EXPIRED 05 - 25 - 08 D07 -294 Parcel No.: 3365901105 Address: 14234 58 AV S TUKW Suite No: City Tukwila Tenant: Name: MCLELAND - WIESER RESIDENCE Address: 14234 58 AV S , TUKWILA WA Owner: Name: MCLELAND - WIESER RICHARD C +H Address: 14234 58TH AVE S , TUKWILA WA 98168 Phone: Contact Person: Name: RICHARD MCLELAND - WIESER Address: 14234 58 AV S , TUKWILA WA 98168 Phone: 206 229 -6123 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: OWNER AFFIDAVIT - RICHARD WIESER Address: Phone: Contractor License No: doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D07 -294 Issue Date: 08/15/2007 Permit Expires On: 02/11/2008 Expiration Date: DESCRIPTION OF WORK: REMODEL FIRST FLOOR INCLUDING PLUMBING, ELECTRICAL, DUCT SUBFLOOR, HARDWARE FLOOR, PARTIAL INSULATION, DRYWALL. REPLACE PLUMBING ON 2ND FLOOR. (MECHANICAL, PLUMBING, AND ELECTRICAL UNDER SEPARATE PERMITS) Value of Construction: $55,000.00 Fees Collected: $1,392.78 Type of Fire Protection: AUTOMATIC FA International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0022 D07 -294 Printed: 08 -15 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signatur I hereby certify that I have read an governing this work will be complie Print Name: doc: IBC -10/06 City oTukwiia Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N N 1 1...i 1/ Ad- A. . permit d know the same to be true and correct. All provisions of law and ordinances ther specified herein or not. The granting of • 't does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio e p o ance of w k. I authorized t -and obtain this development permit. Signature: a �jC Date: i 00r-1— 81) (,t3 ,� s-4 Permit Number: D07 -294 Issue Date: 08/15/2007 Permit Expires On: 02/11/2008 Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -294 Printed: 08 -15 -2007 Parcel No.: 3365901105 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond - 10/06 14234 58 AV S TUKW City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MCLELAND - WIESER RESIDENCE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. D07 -294 ISSUED 08/08/2007 08/15/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 7: All wood to remain in placed concrete shall be treated wood. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: Except for direct-vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 13: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 14: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila D07 -294 Printed: 08 -15 -2007 Permit Center. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 17: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** D07 -294 Printed: 08 -15 -2007 Signature: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: r."— C C\ C L t Gk es.re t/ I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. D07 - 294 Printed: 08-15 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h1tp: f !www. ci. tukwila. wa. us Building Perrrlit — 1'i Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** I q King Co Assessor's Tax No.: 33( .510 1105 —6(o Site Address: 1'i 23 4 . ! . " ll ' .5 $r'T1 f fe re i + Suite Number: — Floor: — Tenant Name: is4f Dr..LI Wv 9 %— New Tenant: ❑ Yes ❑..No m + Property Owners Name: k " CNA ct If O G A+Lp % r i C Ve id, to — La % er.e✓ Mailing Address: t 1 4234 - S E #k Av-e .S' 1 `�C V.-Gu I c � A - '321(' F City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 1 AA a ra h^ c 1,.dc N) - p ��„� 1.QS -Af Day Telephone: ZC&� � Z -- (Pt 2 3 Mailing Address: ( `(2 34 - St'e'm Pt- e S TUkc.J t f CA- (.JA a 2' 16 F E-Mail Address: rcw tfser COIN1C[} LI • 1NA GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: No A 2An Contact Person: E -Mail Address: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: N o Contact Person: E -Mail Address: Q - . .\Applications \Forms - Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City State Zip Fax Number: 206 61.7.S - 6 Co`7 State Zip City Day Telephone: Fax Number: Expiration Date: State Zip City Day Telephone: Fax Number: State Zip City Day Telephone: Fax Number: Page 1 of 6 BUILDING PERMIT INFORMATION 206- 431 -3670 Valuation of Project (contractor's bid price): $ 157C1005 ; '70 JS WO Existing Building Valuation: $ Scope of Work (please provide detailed information): t 'Re cp � 4v p%-,bI v► v v\ 2 ti -,F l oo Will there be new rack storage? ❑ Yes W .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers F. Automatic Fire Alarm El None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ;Z, No If `yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On LineU -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 xj4j I nterior Remodel Addition to Existing Structure - New Type of ; Construction per IBC Type of Occupancy per IBC 1s` Floor j5 W oar 7 � 6 9 2n Floor 700 ' w 3` Floor -too ,�[ �{ �/ Floors thru 2100 - loo ____1___ Basement 2 -1 G f Acessory Structure* Attached Garage Garage ' ©o Of g r Detached Attached Carport ! , IA Detached Carport = w , /A Covered Deck A) IA Uncovered Deck 1\-) IA BUILDING PERMIT INFORMATION 206- 431 -3670 Valuation of Project (contractor's bid price): $ 157C1005 ; '70 JS WO Existing Building Valuation: $ Scope of Work (please provide detailed information): t 'Re cp � 4v p%-,bI v► v v\ 2 ti -,F l oo Will there be new rack storage? ❑ Yes W .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers F. Automatic Fire Alarm El None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ;Z, No If `yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On LineU -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. BUILDING OWN Signature: Print Name: Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date Application Accepted: THORIZED A T• Date: V V 3 2A d 7 m vJ 1 12_1c rn c vela v�0 1etSaY>jerephone: ZOi, " 6 ;25 — 317 (L4 z Avg - s . �'� ty a � -�1t� `API 3 `/ Date Application Expires: bJ z/ ois Q: W pplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Staff Initials: Page 6 of 6 i City of Tukwila Parcel No.: 3365901105 Permit Number: D07 -294 Address: 14234 58 AV S TUKW Status: PENDING Suite No: Applied Date: 08/08/2007 Applicant: MCLELAND- WIESER RESIDENCE Issue Date: Receipt No.: R07 -01626 Initials: JEM User ID: 1165 Payee: RICHARD C. MCLELAND- WIESER Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Description Amount Payment Check 1039 1,392.78 ACCOUNT ITEM LIST: Description BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Payment Amount: $1,392.78 Payment Date: 08/08/2007 10:37 AM Balance: $0.00 841.38 546.90 4.50 Total: $1,392.78 1255 08/08 9710 TOTAL 1392.78 doc: Receipt -06 Printed: 08 -08 -2007 Project: MCLELA06—Welf.Stck Type of Inspection: W fk Lt. ...i Address: Ili 2.161 55 P4.1 S. Date Called: Special Instructions: Date Wanted: „ k1 p-1131 152. Requester: Phone No: INSPECTION RECORD I Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDINGjDIVISION 6300 S outhcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 'Inspector:n-0cl ' Date:. k(2..7 0/ 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: z L / S T y pe o f pec Address: Date Called: Special Instructions: Date Wanted )� a.m Requester: Pbone No: „ 4-229 -6/2 IN SPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. COMMENTS: Inspect • : .00 REINSPECTION FEE REQ P for to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 10 . Call the schedule reinspection. eipt No.: !Date: Corrections required prior to approval. Submittal Sheet CONTRACTOR: JOB NAME: DATE: ULTRATOUCW INSULATION Is a Class -A building material that can be used for both interior and exterior walls as well as most ceiling applications. UltraTouch can be installed in either wood or metal framing cavities and between furring channels by using a simple friction fit. The product is safe to handle and install without the RECFIVED need for protective clothing or special respiratory equipment. ITY OF TUIMI�LA FILE COQ AUG 0 8 2007 C PERMIT CENTER PHYSICAL PROPERTIES PROPERTIES Surface Burning Charactpistics (Fire Hazard Classification) / Corrosion Resistance Fungi Resistance Bacteria Resistance Moisture Absorption Fire Test of Building Material t. C. PRODUCT CODE R- VALUE" 10000 -01316 13 10000 -01324 13 10000 -01916 19 10000 - 01924 19 10000 -02116 21 10000 -02124 21 10000 -03024 30 PERFORMANCE Flame Spread 5 (Class 1) Smoke Developed 35 (Class 1) Passed Passed - No Growth Passed - No Growth Passed - Less Than 15 ob Passed - 1 Hour Rating THICKNESS (MM) WIDTH (MM) 3.5" 89 16.25" 413 3.5" 89 24.25" 616 5.5" 140 16.25" 413 5.5" 140 24.25" 616 5.5" 140 16.25" 413 5.5" 140 24.25" 616 8.0" ' 203 24.25" 616 PRODUCT COMPLIANCES The physical properties of UltraTouch Insulation regularly meet the requirements, specifications, standards and building practices of the following organizations. Environmental Specification #1350 ICC Evaluation Report #1134 LARR ICC ER #1134 BOCA Building Officials and Code Administrators CABO Council of American Building Officials ICBO International Conference of Building Officials LEED Leadership in Energy and Environmental Design SBCCI Southern Building Code Congress International California Bureau of Thermal Insulation Lie. #TI 1367)Reg. # CA T367AZ LENGTH 94" 94" 94" 94" 94" 94" • Excellent Noise Absorbtion • Maximum R -Value • Class -A Fire Rated • No Itch or Skin Irritation • Resists Microbial Growth • No Formaldehyde • A LEED Eligible Product TEST METHOD ASTM E -84 UL -723 ASTM C -739 ASTM C -739 ASTM C -739 63.32 53.04 63.32 64.64 Ai. T 71":" EWED FOR :ODE t1PLIANCI APPROVED THERMAL/TECHNICAL INFORMATION "Tested in accordance with ASTM C -518 at a temperature of 75° F. Higher R-vo lues equal great r insulatingrrprygr. 1 3 0' ( 1, SQ.FT /�B WEIG ? 2. 4 106.07 48 lbs. 2 2 2.34 2.34 2.34 48" 1.22 4 OW Of TIkM1d 4 BUEDINGISION s. 37 lbs. 45 lbs. 57 lbs. ACOUSTICAL PERFORMANCE Sound Absorption was tested in accordance with ASTM E90 -02, ASTM C423 (Type A mounting per ASTM E 795) ABSORPTION COEFFICIENTS 0`@ OCTAVE BAND FREQUENCIES (Hz) R -VALUE THICKNESS (MM) 125 250 500 1,000 2,000 4,000 NRC)STC R - 3.5" 89 0.95 1.3 1.19 1.08 1.02 1.0 1.15 NRC R -13 3.5" 89 21 40 48 52 46 48 45 STC R -19 5.5" 140 0.97 1.37 1.23 1.05 1.0 1.01 1.15 NRC R -19 5.5" 140 40 53 57 63 53 63 57 STC 24053 S. ARIZONA AVE. CHANDLER. AZ 85248 480 -812 -9114 480 - 812 -9633 FAX www.BondedLogic.com Manufacturers Name BONDED LOGIC, INC. Emergency telephone Number (480) 812 -9114 Address (Number, Street, City, State, and ZIP Code) 411 E. RAY ROAD Telephone Number for Information (480) 812 -9114 CHANDLER, AZ 85225 Date Prepared 7/13/01 N/A Signature of Preparer (optional) Boiling Point N/A Conditions to Avoid !PROLONGED TEMPERATURES EXCEEDING 250 ° F Stable Specific Gravity (H = 1) N/A Vapor Pressure (mm Hg) N/A Hazardous Decomposition or Byproducts COMBUSTION PRODUCTS AS FIBER PRODUCTS Hazardous Polymerization Molting Point N/A Vapor Density (AIR = 1) N/A X Evaporation Rate Butyl Acetate = 1) N/A Solubility in Water NONE Appearance and Odor COLOR - WHITE /ALUMINIUM - NO ODOR Stability Unstable Conditions to Avoid !PROLONGED TEMPERATURES EXCEEDING 250 ° F Stable X Incompatibility (Materials to Avoid) N/A Hazardous Decomposition or Byproducts COMBUSTION PRODUCTS AS FIBER PRODUCTS Hazardous Polymerization May Occur Conditions to Avoid ! N/A WiII Not Occur X Material Safety Data Sheet May be used to comply with OSHA's Hazard Communication Standard, 29 CFR 1910.1200. Standard must be consulted for specific requirements. ULTRATOUCH NATURAL COTTON FIBER INSULATION Section II -- Hazardous In Information Hazard Components (Specific Chemical Identity. Common Name(s) l OSHA DEL ACGII.TLV Other Limits Recommended RECYCLED FIBER PRODUCTS I N/A N/A N/A OSHA PARTICULATES NOT OTHERWISE REGULATED - BORAX 5 MOL - Sodium Tetraborate Pentahydrate CAS No. 12179 - 04 - 3 BORIC ACID CAS NO: 10043 -35 -3 10 mg /m 15 mg /m 1 mg /m 10 mg /m 5 mg /m N/A Flash Point (Method Used) Extinguishing Media Special Fire Fighting Procedures Unusual Fire and Expolosion Hazards Route(s) of Entry. I 'Inhalation? Health Hazards (Acute and Chronic) Carcinogenicity None Known Section III -- Physical /Chemical Characteristics Section IV -- Fire and Explosion Hazard Data I N/A ILEL I N/A ANY STANDARD METHOD NO SPECIAL METHOD - MATERIAL IS TREATED FOR FLAME RESISTANCE N/A Flammable Limits NONE KNOWN INTP? INO Section I Section V -- Reactivity Data Section VI — Health Hazard Data YES 'Skin? I NO NONE KNOWN U.S. Department of Labor Occupational Safety and Health Administration (Non- Mandatory Form) Form Approved: OMB No. 121 B -0072 Note: Blank spaces are not permitted. If any item is not applicable, or no information is available, the space must be marked to indicate that. (optional) IIARC (NO Monographs? I UEL I N/A ' OSHA I Regulated? 'Ingestion? IYES Signs and Symptoms of Exposure Medical Conditions Generally Aggravated by Exposure Emergency and First Aid Procedures' Waste Disposal Method Precautions To Be Taken In Handling and Storing Other Precautions Respiratory Protection (Specify Type) Ventilation YES Protective Gloves Other Protective Clothing or Equipment Work/Hygienic Practices Local Exhaust Mechanical (General) OPTIONAL INONE KNOWN NONE KNOWN INGESTION: IF LARGE AMOUNT IS CONSUMED, SEEK MEDICAL ATTENTION Section VII -- Precautions for Safe Handling and Use Steps To Be Taken in Case Material is Released or Spilled I PICK UP LARGE QUANTITIES AND USE OR DISPOSE IN ACCORDANCE WITH FEDERAL AND /OR STATE REGULATIONS COVERING SOLID WASTE DISPOSAL STORE MATERIAL IN DRY PLACE NONE REQUIRED Section VIII -- Control Measures OSHA APPROVED AIR MASK YES NO Eye Protection NOT NORMALLY REQUIRED 'OPTIONAL NO SPECIFIC REQUIREMENT - USE COMMON SENSE Page 2 Special Othe NONE NONE vvaitefebv•i') Permit Application Page 1 Permit Application Index Drawing One - Floor Plan - 1 floor Drawing Two - Site Plan with utilities - Vicinity Map Site Address: McLeland Wieser Residence 14234 - 58 Avenue South Tukwila, Washington 98168 206 - 439 -7096 206 - 229 -6123 mobile Parcel # 336590 - 1105 -06 King County, State of Washington Lot 6, Block 10 Hillman's Seattle Garden Tracts, According to the plat thereof recorded in Vol. 11 of plats, page 24, records of King County, Washington. Owners /contacts Heather McLeland- Wieser Richard McLeland- Wieser 14234 - 58 Avenue South Tukwila, WA 98168 206 - 439 -7096 Building area: First floor. 730 square feet. r -� 8/8/2007 nte oor� REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 3 2007 City Of Tukwila B ILDIN DIVISION General Scope of Work (description) Remodel First Floor (Living Room, Dining Room, Office, Entrance) of existing house built in 1908. Total area of remodel 730 square feet. Scope includes • Demolition of existing lath /plaster walls and ceiling • Install new sheetrock • Replacement of all electrical on first floor • Relocate 125amp main panel • Addition of low voltage to all rooms and home run to media closet • Addition of heating ducting and vents to second floor from existing gas furnace • Addition of Cold Air Return on West wall of Entrance Foyer • General tune up and cleaning of existing furnace • Replacement of flooring with hardwood in all rooms except kitchen • Replacement of kitchen flooring with Marmoleum • Replacement of window in kitchen • Addition of skylight in kitchen RECEIVED CITY OF TUKWIIF it; 0 82007 NtHMIT CENTER Permit Application Page 2 8/8/2007 • Replacement of cabinets • Replacement of all relevant plumbing pipes to kitchen and bath located directly above kitchen on second floor. • Replacement of all existing kitchen plumbing fixtures in kitchen • Replace hot water system with tankless heater and re- circulating system. Location to be determined • Replacement of existing electric cooking range with dual fuel range • Replace existing original fir flooring with hardwood • Repair any first floor flooring so as to ready for installation of new flooring • Install new plywood subflooring where necessary • No new exterior or exterior walls will be added • Rebuild interior wall between kitchen and Dining Room • Colonnade between Dining room and Living room to be added at existing interior wall • Replace wall insulation where necessary General Contractor Owner will act as general contractor. Sub - Contractors Plumbing: Green Planet Plumbing Tyler Brown 2701 California Ave SW Suite 224 Seattle, WA 98116 206 - 412 -3926 tyler ogreenplanetplumbing.com Flooring: LeBlanc Floors Wayne LaBlanc PO BOX 23657 Seattle, WA 206 - 406 -6560 wayne@leblancfloors.com LEBLAFS962RO Electrical: Sun Bright Electric Brian Flack 5423 34 Ave SW Seattle, WA 98126 206 - 369 -8282 briflack@comcast.net 2 Permit Application Page 3 8/8/2007 Heating: American Heating Pat Flack 20924 First Avenue South Des Moines, WA 98198 206 - 353 -3835 Sheetrock - To be determined Total Estimated valuation of the work to be completed: $75,000. Total square footage of remodel area: 700 square feet. Permits: Owner will secure General Contractor. Subcontractors will be responsible for securing all other relevant permits related to their trade Schedule - All dates are start dates August 10, 2007: All contractors secured and permits obtained. August 10: Plumber rough -in August 10: Heating rough -in August 10: Electrical rough -in August 20 Sub - flooring installed. Framing completed. September 1: Sheet -rock installed and mudded September 10: Windows installed September 10: Walls Paint Primed September 20: Hard wood flooring installed but not finished September 20: Kitchen floor installed September 25: Cabinets installed September 30: Counter tops installed 3 Permit Application Page 4 8/8/2007 September 30: Electrical terminated September 30: Plumbing terminated September 30: Heating terminated October 10: Electrical, Plumbing, Heating completed October 15: Painting completed October 30: Substantial completion. Punch lists December 1: Woodwork and trim January 1: Final completion Plumbing Scope Plumbing Contractor (PC) will: 1. Remove all existing waste lines to secone floor bathroom. 2. Provide and install new abs drain, waste, and vents to one toilet, one tub /shower, and one lay on second floor; one kitchen sink. 3. Relocate 4" stack into wall, vent through roof and flash. 4. Provide and install new pex hot and cold waterlines to lay, toilet, tub /shower, kitchen sink and dishwasher, connect to existing copper in crawlspace. 5. Provide and install new three - handle shower valve with trim, spout, and showerhead. 6. Provide and install new gas line to range in kitchen. 7. Provide and install new on- demand, tankless waterheater with necessary venting and water connections. 8. Provide and install new 1" tracpipe gasline to waterheater (existing line is half inch and undersized for any tankless BTU rating). 9. Provide and install new six gallon electric water heater and recirculation pump with loop to furthest fixture on second floor. *note -110 volt is needed for on- demand heater, electric heater and pump; Plumbing is not responsible for electrical circuit. 10. Provide and install new angle stops and risers to lay and toilet on second floor and kitchen sink. 4 Permit Application Page 5 8/8/2007 Heating Scope: Heating Contractor (HC) will: • Run 5 new heat runs through wall to second floor from furnace. • Re -route hall register to kitchen toe kick. • Remove one living room and one kitchen register. • Work to be performed after floor is removed • All ducts in crawl space to be insulated • Seal all new duct work • Add cold air return grate on West wall of entrance foyer • Clean all ductwork • Clean and tune existing furnace • Additional work may be completed upon mutual agreement of Owner and Contractor. Such change orders will impact contract and costs will be negotiated between owner and contractor. Electric Scope Electrical Contractor shall: • Install new 125 amp main panel in new location in stairs area and new wiring to meter base, main bonding included • remove old panel and route old circuits from junction box in wall of bathroom to new location • Install following: o GFI protected outlet in kitchen (2) o Electrical outlet 12ov 20 amo ckt. In kitchen (10) o Wall mounted fixtures in kitchen by sink (2) o Switches and wiring for wall finxtures by sink, disposal (2) o 2 -15 amp dedicated circuits wiring from panel fro undercabinet hotwater & disposal (1) o 15 amp dedicated circuit wiring from panel for dishwasher (2) o Connect cord to dishwasher o 20 amp dedicated ckt wiring from panel fro dishwasher, refridgerator (2) o Connect cord to dishwasher o 20 amp dedicated ckt wiring from panel fro microwave hood (1) o Undercabinet lighting fixture and wiring (fixture sold separately (4) o Ceiling mount fixture in kitchen (1) o 3 -way switch and wiring for kitchen ceiling fixture (1) o Sconces in dining room (4) o Electrical outlet 120v 20 amp ckt. In dining room and office (8) o 3 -way dimmer /switch for dining room sconces (1) 5 Permit Application Page 6 8/8/2007 o 40 amp wiring to dual range install outlet and cover (1) o 3 switches by front door to control 3 way lighting(1) o Ceiling mount fixture in office (1) o 3 -way switches and wiring for office (1) o Switch for some switched outlets in living room and 4 outlets (5) • Additional work may be completed upon mutual agreement of Owner and Contractor. Such change orders will impact contract and costs will be negotiated between owner and contractor. Sheet Rock • Contractor will hang sheetrock, tape and mud all rooms with a smooth finish • Contractor will provide all materials • Additional work may be completed upon mutual agreement of Owner and Contractor. Such change orders will impact contract and costs will be negotiated between owner and contractor. Flooring • Contractor will install new hardwood flooring in entrance, dining, living room • Complete sand & finish wood floor • Apply 2 Coats of OSMO polyx Oil • Materials: 4" or 5" Red Birch 6 04 -04 -2008 RICHARD MCLELAND - WIESER 14234 58 AV S TUKWILA WA 98168 RE: Permit No. D07 -294 14234 58 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/25/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall, it Technician Permit File No. D07 -294 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: Av& Apt Building Division b5 Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 - 294 DATE: 08 - - PROJECT NAME: MCLELAND - WIESER RESIDENCE SITE ADDRESS: 14234 58 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued .l atkli 1 O Fire Prevention lanning Division Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator No further Review Required DATE: DATE: n DUE DATE: 08-09-07 Not Applicable E Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 09-06-07 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: CITY OF TUKWIL4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Permit Center /Building Division: 206 -431 -3670 Public Works Department: 206433 -0179 Planning Division: 206 -431 -3670 STATE OF WASHINGTON) COUNTY OF KING ) AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION ss. )'\62Arj c [please print] 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration re u ement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. � 4 , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. \applications\8 -2004 affidavit in lieu of contractor registration APPLICANT , states as follows: L, "(NJ D i -Am F + + � r Signed and sworn to before me this Q ` , ? SAR .. � ' 'y, / day of 7q1i14�L(St , 200 7 NS c) '2 � O a __ � %1 N I Y PUBLIC in and for the State of Washington, Residing at iki Name as commissioned: My commission expires: PERMIT NO.: 1704 1-1 , County. ' 1 , n'e fraf'(< 5 --a4- 0-7 w 18.27.090 Exemptions. This chapter shall not apply to: 1. 2. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district or other municipal or political corporation or subdivision of this state; 3. Officers of the court when they are acting within the scope of their office; 4. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 5. Any construction, repair or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 6. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of the structure; 7. Any construction, alteration, improvement or repair of personal property, except this chapter shall apply to all mobile, manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 8. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 9. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 10. Any work or operation on one undertaking or project by one or more contractors, the aggregate contract price of which for labor and materials and all other items is less than $500.00, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in all instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into \applications\8 -2004 affidavit in lieu of contractor registration contracts of amounts less than $500.00 for the purpose of the evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 11. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except then any of the above work is performed by a registered contractor; 12. An owner who contracts for a project with a registered owner; Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but his exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 14. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 15. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 16. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 17. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work. 1Ze ce cOsAn w/ ir cAz c t, o, U s I No.," 17-5 c v V Y`eL <41 na 'tom .5 <Th l.4 t 4 LAG. 1Nt..-e.. - �, 4-0 ta 4 7-CA VI 5 t tz SEPARATE PERMIT REQUIRED FOR: Meidtankal • . - , Electrical . Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j 3; C/)01 (N SSGoPL ) 11111111111MIWMINIMINIO MIIIIMMENNEMMINI EXP1 E MAY 2 5 2008 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 3 2007 City ukwila BUILDING DIVISION FILE COPY Permit No. 1-2 Ran review e7,proval is subject to errors end omission Approval of conotru•ction dcaament; cocs not authorize the violation c? c- f c -- - - Coco or crdinenc.e. Receipt of approved C•:::.1 r. 7 .1 b C. ::.: cr viedged: faq General Scope of Work (description) g�� Cit� of Tukwila Remodel First Floor (Living Room, Dining Room, Office, Entrance) of exisfi�i g i `r9V908. Total area of remodel 730 square feet. • Demolition of existing lath /plaster walls and ceiling • Install new sheetrock • Replacement of all electrical on first floor • Relocate 125amp main panel • Addition of low voltage to all rooms and home run to media closet • Addition of heating ducting and vents to second floor from existing gas • Addition of Cold Air Return on West wall of Entrance Foyer • General tune up and cleaning of existing furnace • Replacement of flooring with hardwood in all rooms except kitchen • Replacement of kitchen flooring with Marmoleum • Replacement of window in kitchen • Addition of skylight in kitchen • Replacement of cabinets • Replacement of all relevant plumbing pipes to kitchen and bath located directly above kitchen on second floor. • Replacement of all existing kitchen plumbing fixtures in kitchen • Replace hot water system with tankless heater and re- circulating system. Location to determined • Replacement of existing electric cooking range with dual fuel range • Replace existing original fir flooring with hardwood • Repair any first floor flooring so as to ready for installation of new flooring • Install new plywood subflooring where necessary • No new exterior or exterior walls will be added • Rebuild interior wall between kitchen and Dining Room • Colonnade between Dining room and Living room to be added at existing interior wall • Replace wall insulation where necessary furnace Date: u 2 ©Q RECEIVED CITY OF TUKWILA AUG 0 8 2007 PERMIT CENTER be 9 1006 N.E. Ravenna Blvd Seattle WA 98105 voice 206- 524-2808 fax 206 -523 -1019 GREgg building DESIGN 2 .5e bck 37J± .1:tJ Site Plan 14234 58 Avenue South Tukwila, WA 98168 King County Assessor's Tax number 336590- 1105 -06 Created: August 4, 2007 Scale: 1" = 20' 1 of 1 sheets i ih 5 PL- IQ? arcs lc `16 It North Vicinity Map 14234 -- 58 Avenue South Tukwila, WA 98168 King County Assessor's Tax Number 336590-1105-06 S 136?l St .. _. 5 Zi , •. Joseph' Faster Memorial zt 2C07 MapQuest t:5 Poster isQlf t.i» S 1 •w ZVI �' . m Tukvviia ' , ! tll n : S 147th St Q� a 5149 st s 143rd sr 5 !43rd P1 •. S 154th Sr Fort Dee Park '4_6) , C,2OQ724AVTEO EX MAY 252008 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 3 2007 City Of Tukwila B ILDIN . DIVISION RECEIVED CITY OF TUKIn ""IA AUG U 8 2001 PERMIT CENTER