Loading...
HomeMy WebLinkAboutPermit D07-300 - HAMPTON INN - ADDITIONHAMPTON INN 7200 S 156 ST D07 -300 Parcel No.: 2423049014 Address: 7200 S 156 ST TUKW Suite No: Tenant: Name: HAMPTON INN Address: 7200 S 156 ST , TUKWILA WA doc: IBC -10/06 City\.,)f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: TUKWILA HOTEL L L C Address: 600 E RIVER PARK LN STE 205 , BOISE ID 83706 Phone: Contractor: Name: OWNER AFFIDAVIT - THOMAS DUSBABEK Address: 1938 SPRINGBROOK LN , BOUISE ID 83706 Phone: 208 - 338 -9696 Contractor License No: DEVELOPMENT PERMIT Contact Person: Name: CARL PIRSCHER Address: 19500 BALLINGER WAY NE STE 200 , SHORELINE WA 98155 Phone: 206 -368 -9668 * *continued on next page ** Permit Number: DOT -300 Issue Date: 10/01/2007 Permit Expires On: 03/29/2008 Expiration Date: DESCRIPTION OF WORK: RAISE THE FLOOR LEVEL OF A NON - ACCESSIBLE PORTION OF THE RECEPTION /SITTING AREA TO ONE UNIFORM LEVEL BY THE ADDITION OF A NEW OVERFRAMED FLOOR SYSTEM. Value of Construction: $10,000.00 Fees Collected: $375.06 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0020 D07 -300 Printed: 10 -01 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: doc: IBC-10/06 City o,Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Thee: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Lit.8L I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th erformance of I am authorized to sign and obtain this development permit. Signature: Date: /6/A 7 Print Name: Mani tQ- S // pos• 6 413E /( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Permit Number: DO7 -300 Issue Date: 10/01/2007 Permit Expires On: 03/29/2008 Date: L O `t/ D07 -300 Printed: 10 -01 -2007 Parcel No.: 2423049014 Address: 7200 S 156 ST TUKW Suite No: Tenant: HAMPTON INN 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 7: All wood to remain in placed concrete shall be treated wood. PERMIT CONDITIONS * *continued on next page ** Permit Number: D07 - 300 Status: ISSUED Applied Date: 08/10/2007 Issue Date: 10/01/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D07 -300 Printed: 10 -01 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: 7i %1 H t( doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: iG //: 7 D07 -300 Printed: 10 -01 -2007 CITY OF TUKWIL.t -e Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/lwww.cltulcwila.wa.us Building Permit No. 1)0 — 300 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION '^ -t-� King Co Assessor's Tax No.: 2-42-10 ' 0 19 Site Address: - 7 ) O S. 1 5(o f r l St-. 1 u kt 1 Id, WA 'MN' Suite Number: Floor: Tenant Name: Ha rn pl-on Inn Property Owners Name: bob SU 1'4-s Mailing Address: - 0 New Tenant: Yes • • f: I. 1.• I_ • Name: earl Firs c.hcr Mailing Address: Iv II i i i E -Mail Address: (nr i �P @ e .DA ARC . cn iM City . JO i $ 0 it State CONTACT PERSON — who do we contact when your permit is ready to be issued Day Telephone: ( - 56643 A State Zip City Fax Number: an ti -3 (oR - q55' R GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: State �..No Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHI'1 OF RECORD - All plans must be wet stamped by Architect of Record Company Name: CJ)M P I S5C R ,A IR CR I T ECtS Mailing Address: 11 500 B t'1rjr Way NP, suNe athri2.(il wk a$ L 5 �" " u Ei ty stat Z ip Contact Person: f1�(� I S CIn �r' Day Telephone: .) - 3�n 8 - q ( R E -Mail Address: (LIr1 f C. . CD M Fax Number: 2P6- 36?- q-. ENGINEER OF RECORD - All plans must be wet stamped by Engineer" of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:Mpplications\romu- Application On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page 1 of 6 BUILDING PERMIT INFORI,..:TION - 206 - 431 -3670 �. Valuation of Project (contractor's bid price): $ E3f. . 10,0100 Existing Building Valuation: $ Scope of Work (please provide detailed information): P4(SQ. i i 1p nO f 1 4.VLI o ' a I' ) n-a(CQs salltQ, por +tin ihe- or Qph nn ci ttinq area -o nne uhlThrrn /O.V.e I by 4-h .. acki •4irin ar a lute aver f red ffnvr sys m. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq it): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None QAApplicatiau'Fotms- Applications On Lma\3 -2006 - Pamit Application.doc Revised: 9 -2006 hh ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 at Floor r Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORI,..:TION - 206 - 431 -3670 �. Valuation of Project (contractor's bid price): $ E3f. . 10,0100 Existing Building Valuation: $ Scope of Work (please provide detailed information): P4(SQ. i i 1p nO f 1 4.VLI o ' a I' ) n-a(CQs salltQ, por +tin ihe- or Qph nn ci ttinq area -o nne uhlThrrn /O.V.e I by 4-h .. acki •4irin ar a lute aver f red ffnvr sys m. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq it): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None QAApplicatiau'Fotms- Applications On Lma\3 -2006 - Pamit Application.doc Revised: 9 -2006 hh ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. BUILDING 0 Signature: Print Name: Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. D a t e Application Expires: a_-_[01-- D Date Application Accepted: 8 - ID QMpp,iatiauWamrApplications On line\3.2006. Pamir Appticatian.doc Revised: 9.2006 bh Zip Staff Initials: 1 4_ Page 6 of 6 i Parcel No.: 2423049014 Address: 7200 S 156 ST TUKW Suite No: Applicant: HAMPTON INN Receipt No.: R07 -01661 Payee: CDA PRISCHER ARCHITECTS TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 000/322.100 000/345.830 000/386.904 RECEIPT Initials: WER Payment Date: 08/10/2007 11:31 AM User ID: 1655 Balance: $0.00 Amount Payment Check 14694 375.06 Account Code Current Pmts 224.58 145.98 4.50 Total: $375.06 Permit Number: D07 - 300 Status: PENDING Applied Date: 08/10/2007 Issue Date: Payment Amount: $375.06 1387 08/10 0710 TOTAL 375.06 doc: Receipt -06 Printed: 08 -10 -2007 Proiect: #/f/ii —.7-it) Ai Type of Laspection: ,' //Vs/ / Address: 7206 S /57s4 Date Called: Special Instructions: Date Wanted: / — l Requester: Phone No 2498— 57 -7/ 67 21-NSPECTION RECORD Retain a copy with permit PERMFO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 I Atpproved per applicable codes. El Corrections required prior to approval. COMMENTS: Peren (,1 p Weyi7(AJA/ 00 REINSPFCTION FEE REQUIREDPrior to inspection, fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date: c2 Receipt No.: 'Date: D07-3 \AL Project: /47 O4J -2 VA/ Type of Inspec3 ion: n. ��/v6K ✓ -l 92P-P Address: 72°6 5 /5 Date Called: Special Instructions: ,. Date Wanted: /2 — d 7 Requester: Phone No: ? Oc -v G 7-/16 INSPECTION NO. CO ItAM ENTS: Inspector: INSPECTION RECORD Retain a copy with permit Date / eceipt No.: 'Date: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. � .00 REINSPECTION FE REQUIRED. P or to inspection, fee must be aid at 6300 Southcenter B vd.. Suite 1 Call the schedule reinspection. GENERAL STRUCTURAL NOTES THE FOLLOWING NOTES APPLY EXCEPT WHERE SHOWN OTHERWISE CODE International Building Code IBC (2006) STRUCTURAL LOADS DINING FLOOR LIVE LOAD = 100psf COLD FORMED STEEL Cold formed steel framing members shall be manufactured by a member of the Steel Stud Manufacturers Association, SSMA, and shall comply with ICC report ER- 4943P. All 18, 20, 22, and 25 gauge (43, 33, 27 and 18 mils thick, respectively) material shall conform to ASTM 446 Grade A with fy = 33,000 psi. Design manufacture and fabrication to be in accordance with the current AISI Specification. (No deferred submittals) tO7 300 EXPIRES 5/17/ 6 1 CORRUGATED STEEL FORM Steel form deck to be "shallow vercor" galvanized deck by VERCO of the gage and depth noted on plans. Fasten to supporting members with #8 screws per the plan. SCOPE OF STRUCTURAL ENGINEERING SERVICES The Structural Engineer has performed the structural design and prepared the structural working drawings for this project. The construction must be performed in strict accordance with the structural drawings. Any deviation from the drawings must be approved in writing by the Structural Engineer. Errors and/or omissions found on the structural drawings must be brought to the Structural Engineer's attention immediately. Architectural drawings are the prime contract drawings. Structural drawings shall be used in conjunction with Architectural drawings. Primary structural elements are dimensioned on the Structural plans and details. The General Contractor shall verify and coordinate dimensions among all drawings. Any discrepancies, contradictions, or omissions shall be reported to the Architect for resolution prior to proceeding with work or fabrication of the item(s) in question. The Structural Engineer is responsible for the design of the primary structural system shown on the plan, except for any components noted above. Responsibility for any secondary structural and non - structural systems not shown on the structural plans rests with someone other than the Structural Engineer. The structure shown on these drawings is structurally sound only in its completed form. The Contractor shall provide all necessary bracing to stabilize the building during construction. The Structural Engineer is not responsible for, and will not have control of, construction means, methods, techniques, sequences or procedures, or for safety precautions and programs in connection with the construction work, nor will he be responsible for the Contractor's failure to carry out the construction work in accordance with the contract documents. Field measurements and the verification of field dimensions are not part of the Structural Engineer's responsibility. The Contractor must check all (assumed) existing conditions shown on these drawings for accuracy and notify the Structural Engineer of any discrepancies. Omissions from the drawings or specifications or the inadvertent mislabeling of details of work which are manifestly necessary to carry out the intent of the drawings and specifications, or which are customarily performed, shall not relieve the Contractor from performing such omitted or inadvertent mislabeled details of the work but they shall be performed as if fully and correctly set forth and described in the drawings and specifications. DEFERRED SUBMITTALS The following items are considered to be deferred submittals under Section 106.3.4.2 of the International Building Code and must be submitted to the Architect or the Engineer for review. These items will then be forwarded to the Building Official for approval. The deferred submittal items shall not be installed until their design and submittal documents have been approved by the Building Official. RE ;r V r AUG .1 O 'raid L_ K. ETERSON •Z)TREHLE MARTINSON, INC. CONSULTING ENGINEERS 2200 SIXTH AVE.,SUITE 601 SEATTLE, WASHINGTON 98121 OFFICE (206) 622-4580 / FAX (206) 622-0422 JoB. ,ry) Premi DATE - 7 - e77 BY: le) SUBJECT: Pm iSit (RY ovE12 • , /z / A/ 6.e rn A C-0A/ ov•e 6,A A.v t4izeAok. " D . • • • • • . • • . • : tz;T EX I sl" 4 e47A,t4, hIt.-7-/ • • : RECEIVE, AVG1 0 nu • • ;.. . . . 'S RJC - 47 PiA/s -YV 4- -To P) 7 PERMIT EN Li . ..*■1•2 To u 4gi eqD 8'650 6 4- 43 : - 0S2.1‹. A7 Q tc7 ; • errP...) eb.41b • 33253 i ?Zors-ri-S ° sio EXPJFIES-51171-- - D ,r ETERSON ;;JTREHLE inARTINSON, INC. CONSULTING ENGINEERS 2200 SIXTH AVE.,SUITE 601 SEATTLE, WASHINGTON 98121 OFFICE (206) 622-4580 / FAX (206) 622-0422 I -I- I i ■ • 1 : : 4 J.- ' : .. I.... ' • '-!- ! i '• I i : 1 * 4 JOB: h /AM/ ese)27,270.Q... DATE: 7 07 BY: SUBJECT' . •. • •, ..... YetroS /ea ASE T/ffbA/V.,)( • 4A.9 (2) We SekEzt - 70fr ge REtE,ItiF• - AUG 1 0 PERMIT CENITEf 'EXPIRES 5/17/ 01 J f Lam COLD-FORMED STS FLOOR FRAMING NOTES 1. ATTACH DECK TO JOISTS WITH #8 SCREWS AT 12 (UNO). WELDED WIRE FABRIC 6 x 6 - W1.4 x W1.4 TO BE USED IN ALL SLABS. 2. ALL MEMBERS ARE TO BE UNPUNCHED. 3. SCREWS SHALL BE SELF - DRILLING. MINIMUM EDGE DISTANCE AND C.C. SPACING TO BE Y ". 4. BRIDGE ALL STUDS AND JOISTS PER MANUFACTURER'S RECOMMENDATIONS. 5. SEE THE GENERAL NOTES FOR ADDITIONAL INFORMATION. RECEIVEL AUG. 1 0 2007 • PERMIT ,T.-: ���a o t;�i August 16, 2007 Carl Pirscher 19500 Ballinger Wy NE, Ste 200 Shoreline WA 98155 City of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number D07 -300 Hampton Inn — 7200 S 156 St Dear Mr. Pirscher, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have included comments from the Fire Department. At this time the Building, Planning, and Public Works Departments have no comments. Fire Department: Alan Metzler at 206 575.4407 if you have questions regarding the following comment. 1. Please fill out the Fire Protection/Hazardous Materials section of the permit application. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenfer service. , If you have any questions, please contact me at (206) 431 -3760. encl File No. D07 -300 PAPemut Center\Correction Letters \2007\DO7 -300 Correction Ltr #1.DOC jem Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -300 DATE: 08 -27 -07 PROJECT NAME: HAMPTON INN SITE ADDRESS: 7200 S 156 ST Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division ❑ Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -28 -07 Complete Please Route rv TUES/THURS ROUTING: �►i I D1 Fire Prevention Incomplete Structural Review Required Planning Division Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09 -25 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 ACTIVITY NUMBER: D07 -300 DATE: 08 -10 -07 PROJECT NAME: HAMPTON INN SITE ADDRESS: 7200 S 156 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: tho Building Division Complete TUES/THURS RQCJTING: Please Route Documents/routing slip.doc 2 -28 -02 `HERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 511 dmittl 64 Fire Prevention Pub is Works �� Structural 111 Permit Coordinator �r �, • " ' qua.. DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required Nit Kik (44 --e Planning Division X DUE DATE: 08 -14 -07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 09 -11 -07 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Fa Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: OS C'k Departments issued corrections: Bldg ❑ FireX Ping ❑ PW ❑ Staff Initials:i REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Nor City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Hampton Inn Project Address: 7200 S 156 St Contact Person: (Awl ' T oh.w. Summary of ' evisi ' n: Entered in Permits Plus on \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: D07 -3 00 Received at the City of Tukwila Permit Center by: 9-)- Steven M. Mullet, Mayor Steve Lancaster, Director Phone Number: 2i4c.=> ' SGb G )16 IREUEIV t1.3 CITY OF TUKWILA AUS 2720011 FERMITC'tgIER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision RJ CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Permit Center /Building Division: 206 -431 -3670 Public Works Department: 206 - 433 -0179 Planning Division: 206 - 431 -3670 STATE OF WASHINGTON) ) ss. COUNTY OF KING AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION 7 !a vv s /3A /3 15 7c [please print] 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. l'/ , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. \applications\8 -2004 affidavit in lieu of contractor registration PPLICANT Signed and sworn to before me this NOT RY � S't - — day of PERMIT NO.: , states as follows: Odbe r a UBLIC in and for the State of Washington, 20 01 Residing at 1< , ,,,, , County. Name as commissioned: Y'(2)-01- .. f j-wer t e My commission expires: ,695_ °2 9 -I O 18.27.090 Exemptions. This chapter shall not apply to: 1. 2. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district or other municipal or political corporation or subdivision of this state; 3. Officers of the court when they are acting within the scope of their office; 4. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 5. Any construction, repair or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 6. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of the structure; 7. Any construction, alteration, improvement or repair of personal property, except this chapter shall apply to all mobile, manufactured housing. A mobile/manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 8. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 9. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 10. Any work or operation on one undertaking or project by one or more contractors, the aggregate contract price of which for labor and materials and all other items is less than $500.00, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in all instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into \applications\& -2004 affidavit in lieu of contractor registration contracts of amounts less than $500.00 for the purpose of the evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 11. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except then any of the above work is performed by a registered contractor; 12. An owner who contracts for a project with a registered owner; 13. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but his exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 14. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 15. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 16. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 17. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation ` to perform highway construction, reconstruction, or maintenance work. NO 101 Iativsci s .l1wa3d I Q DR AJ'tN: DO Of4eOK_ CP JOB NO: 7031 GENERAL NOTES ALL CONSTRUCTION SHALL CCNFOR I TO 71$ LATEST EDITION CF 11-E INIER 4ATICI4AL BUILDING CODE (2006 EDITION). ALL CONSTRICTION SHALL BE DONE IN ACCORDANCE WITH TI-ESE PLANS AND PROJECT SPECIFICATIONS. GENERAL CONTRACTOR IS RESPONSIBLE FOR PERMITS. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS IN T1.E EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS OR BETIJEEN THE PLANS AND SPECIFICATIONS NOTIFY TI-E ARCHITECT IMMEDIATELY SPECIAL INSPECTORS SHALL 13E AFFROVED BY THE BUILDING OFFICIAL PRIOR TO CONSTRUCTION. FINISH FLOOR R12=ERB4CE DATUM EQUALS (0' -0 9. REFER TO CIVIL DRAWINGS FOR ACTUAL SITE ELEVATION. ALL DIM ENSIGNS ARE TO R=ACE CF CONCRETE, MASONRY, FACE OF FRAMING OR COLUMN CENTER LINES UNLESS NOTED OTHERWISE. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WOOD OF ANY SPECIE OR FOUNDATION GRADE CEDAR OR REDWOOD. ALL MARKED BY AN APPROVED TESTING AGENCY ALL WOOD FORMS USED FOR CONCRETE, 114 THE GROUND OR BETUEE M FOUNDATION SILLS AND THE GROUND SWAJ L BE REMOVED. PROVIDE HORIZONTAL FIREBLOCKI G IN ALL WOOD FRAME WALLS AT 10'-0° GN CENTER AND 11.1-ERE FRAME WALLS PENETRATE CEILING. FIRi =BLOCK IN ACCORDANCE WITH I.B.C. SEC ill. INTERIOR WALL AND CEILIIJCs FINISHES FCR AREA5 SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING OF 200. ALL DECORATIVE MATERIALS ARE REa111R1=D TO BE MAMTAItED IN A FL.A' E- RETARDANT CONDITION. POST NO SMOKING° SIGNS M ACCORDANCE WITH THE WASHINGTON CLEAN INDOOR AIR ACT 14BJ62. EXPOSED INSULATION MATERIALS INCLUDING FACINGS AND VAPOR BARRIERS SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25, AND A SMOKE DENSITY NOT TO EXCEED 450, OR SHALL BE IN SUBSTANTIAL CONTACT WITH THE WALL OR CEILING SURR=ACE FINIS1 -L SEE IBC. SECTION 1193. HAMPTON INN TENANT IMPROVEMENT 7200 SOUTH 156th ST. TUKWILA, WA. 98188 PERMIT SET AUGUST 7, 2007 SYMBOLS INTERIOR ELEYATLOly A11 4 IDENTIFICATION ROc� 1 S rt1 L NAME RaaK rum BUILDING SECTION eami )N ICIENTIFICA,TION LOCATED ON SHEET- SECT ON eecnOPL 9 TFICATION LOCATED ON SFEET DETAIL IDENTIFICATION LOCATED ON BEET TED ON SHAT MATERIAL COVES 2nd No WALLSALLOISCOT 3rd No CUING NE(GHT e i APE FOOTAGE 1R1P t"IA E LETTERS 1141 ONE DIRECTION NPIEERS IN THE 011-ER DOOR SYMBOL tem 5 11L4.L IDENTIFICATION WINDOW SYMBOL IDENTIFICATION CENTER LAM .- PROPERTY LBO CENTER LINE OP STREAM MATCH LIFE 411R-------2444:4EP PORTION IS SIDE C.ONINCE ED 114E NORTH ARROW ELEVATION MAPPER FNIBH GRADE ELEVATION TOP OP CURB TOP OF PAVEMENT NEUJ GCNTaI R EXISTING CONTOUR ABBREVIATIONS L 1 • A8. ACP ACT. APP. AGGR AUK ANOJ7 APPRPX AR AI ABPFL BD. ELCG. ELK ELM. EM. BOTJI3TM BUR CAB. CE. cot a�. C.J. C CLR COL. CONE POW COMM COWL COON® CT. CTR GT$K DBI- Dan Ora DET. DL4 Dal. VN. DR D.S. E EA EWA EJ. ELF. ENCJ_ EP. EGTUIP. AND AWLS AT SINE DIAMETER OR ROUND PERPENDICULAR POUND OR NUMBER ANCHOR BOLT A5P1 -LALT CONCRETE ACOUSTICAL TILE ABOVE FIWSH RR AGGREGATE ALUMINUM MODIXEp APPROXIMATE ARCHITECTURAL ASPHALT BOARD BUI BLOCK BLOCKING BEAM BOTTOM BUILT UP ROOF CABIkET CATCH BASW CEMENT CHANNEL CONTROL JOINT CEILING CLEAR CLEAN OUT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTIMIOUS COORDINATED CERAMIC TILE CENTER =INTER SUNK EAST EACH EXTERIOR INSULATION FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR ENCLOSURE ELECTRCAL PANEL EQUAL EQUIPMENT EXIST. EXPO PD. PE FT. PTL'rt FLIER. GYP. DOUBLE JNd'8 DEPARTMENT DETAIL LAM. DIAMETER LB. DI'1ENSION 1N DOWN LOO. DEPARTMENT OF TRANSPORT DOOR MAIL MAX. DOWNSPOUT DRAWING MFR TIFL PECK M MTD. MTL EXISTING DQ'OSED EXTERIOR RUR4ISHE P 5Y OWNER INSTALLED SY CaNT'R FLOOR DRAIN FIFE DcTING- UISHER FIRE HYDRANT FINISH FLASHING FLOOR FLUORESCENT FOUNDATION FRAMING FIBERGLASS REINFORCED PLASTIC FOOT OR FEET FOOTING FURRING GAUGE GALVANIZED GENERAL CONTR GLASS GROW GRAPE GRC JP G'PSIJI WALL BOARD GYPSUM HARDWARE HARDWOOD HOSE SIBS HANDICAP HOLLOW METAL HORIZONTAL HOUR HEIGHT HEAVY INSTALLATION INSULATION 4TE'RROR JOINTS LAMINATED POUND LOCATION MATERIAL MAXItiLIM MANUFACTURER MANHOLE MEGI-LANlCAL MNIh4J1 MISCELLANEOUS MOUNTED METAL NORTH NOT IN CONTRACT NUMBER NOT TO SCALE OTC. 0/ PL AMID. PP. PLAN P., R RD. REC. REF RED REQ'D. RM. RU 8. SOUTH SQ. SOUP CORE SCI SCHEDULE S.F. STORE FRONT Siff. SHEET OHM SHEATHING SIN. SIMILAR SJ. SCQ JONT SPEC. SPECIFICATIONS SGL 5 o1APE SIP. STANDARD OIL STEEL STOR STORAGE 811EJGT. STRUCTURAL 8t : 5uSFEMED &� Y. STAIN AND VANISH SYht STTII1ETTRICA1- Sew) SIDEWALK T. Tr. TEL. ti G. TF�IC TOR TP. TIU. TIP. I1BC. uNT: ION. ON CENTER OvER OPPOSITE UNIFORM BUILDING CODE UNFNISWED UNLESS OTHERIWSE NOTED VERT. VERTICAL PLATE PL.111100P POWER POLE PLASTIC LAMINATE PRESSURE TREATED RADIUS OR RISER ROOF DRAIN RECOMMENDED REFERENCE REINFORCED REQUIRED ROOM RAIN WATER LEADER TREAD TOP OF CURB TELEPHONE TONGUE AND GROOVE THICK TOP OF PLATE TOP OF PAVEMENT TOP OF WALL TYPICAL UL WEST ay WITH WD. WOOD UA�UI WINDOW UI/O WITHOUT MN? WATEWROOF UIR WATER RESISTANT UECT. WAINSCOT arr. MIGHT PROJECT DATA ADDRESS: SITE AREA: AREA OF WORK: CONSTRUCTION TYPE: BLDG. DEPT OCCUPANCY: OCCUPANCY LOAD: 1200 SOUTH 186th STREET - TUKWILA, WA. 98188 62,610 SQ. FT. 888 SQ. FT. 1 -IOTEL TYPE II F.R CITY OF TUKWILA 5 FILE CO - Permit No. (flan review r. 7- p rova1 Is subjel to errors and CMISSICIIS Approval c,' documents does not authortaR the violcaci c; 4:7.7 cccepz code or ordlnaru.'e. Reaette apprcvoJ C:77 c7d a. viedged BY Date: _L,Z /O 7 City of Tukwila BUILDING DIVISION PROJECT PIRECTORY CLIENT: NORTHWEST HOSPITALITY GROUP 600 E. RIVER PARK LANE, SUITE 205 BOISE, ID. 83106 (20S) 343 -3439 (20S) 344 -4148 FAX CONTACT: ROBERT J. SUITS ARCHITECT: CDA ARCHITECTS, INC. 19500 BALL INGER WAY N.E. SUITE 200 P.O. 13OX 55429 SEATTLE, WA. 95155 (206) 368 -9665 (206) 36S -9558 FAX CONTACT: CARL F. PIRSGHER STRUCTURAL PSI CONSULTING ENGINEERS 2200 SIXTH AVENUE, SUITE 601 SEATTLE, WA. 98121 (206) 622 -4580 (206) S18 -1539 FAX CONTACT: MINI . VIMAWALA rvvi --=- r. ;. 1.a SHEET INDEX AEGHEEEMMEAL-WAELI t T -0.1 COYER SHEET T -U STRUCTURAL FLOOR PLAN SURVEY DISCIPLINE : 5 -1 LAND SURVEY SRC- AQUIRED FORT ' Electrical MettanIcal pl d Gas PIPo • e f Ti ikwiia REVISIONS 1 No changes shall be made to the scope I of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees VICINITY" N VICINITY MAP NOT TO SCALE AUG 10 2007 '1;ENI'Eh. 00 300 a d a CDA PI RSCHER ARCHITECTS ODA + Flrscher Architects Ici500 Ballinger Nay NE, Bribe 200 Seattle, iNoshtnc3ton 48155 (2067368 -166S Eax (206)368 -V5SO SHEET: OF: SHEETS ��� I las 1.11 11/2" NOIR"IAL ..__ i 1 -1/2" = l'-0" 800 5162 -43 5162 -43 • 24" GAL LEDGER STL. 0.C. (TYP.) JOISTS "x28 ga. 31VCI 800 OVE < WT. CONC. "SHALLOW VERCOR" } DECKING Q DRAWN: DQ CHECK: CF .ao5 NO: 1031 ��� LOWER LOSSY EXT.BULKHEAD 11/2" NOIR"IAL ..__ i 1 -1/2" = l'-0" 800 5162 -43 5162 -43 • 24" GAL LEDGER STL. 0.C. (TYP.) JOISTS "x28 ga. 800 OVE < WT. CONC. "SHALLOW VERCOR" } DECKING ��� LOWER LOSSY EXT.BULKHEAD TITS 1031-no (- 3 EDGE 0 STAIR LOCATION 1" = 1 l -o" 5O4On..1OOEAS C1 LOE313Y /STOP EDGE ..__ i 1 -1/2" = l'-0" 5O4OD..1OOLSE FLOOR TYPES (2) #a SCREWS 24" o.c. EXISTINS CONCRETE 800 SI62 -43 0 24" oz.. W/ WEB STIFFENERS 0 EA. SUPPORT 4 ENDS (STIFFENERS NOT SHO1NN FOR CLARITY - SEE 4 /A -TI.1) - . — (2) #S SCREWS PER SLK6. FINISH (BY OWNER) OVER 11/2" NORMAL WT. CONCRETE OVER GALV. %" x 2S ga. "SHALLOW VERCOR" DECKING. (2) 800 5I62 -43 BACK -TO -BACK 0 48" o.G. NI (2) ROWS OF HILTI 0.145 + PINS 48" oc., STAGGER, TO (E) CONC. T.O. BULKHEAD PROTECT EXISTING WINDOW CONDITION DURING CONSTRUCTION STL. JOISTS PER PLAN 4 4 4 a 4 4 4 a 4 4 4 4 d 4 4 OMIT 0 SIM. 800 5162 -43 LEDGER vi! (2) RCM GF I4LTI 0.145" • PINS 12 " p,0 y STAC7 •• U.. I•• :ml I:: I.. ••• e 4 4 4 4 4 EXISTING WALL BEYOND 400 5162- 43W1-111-710.146' 4PINSa " oa —4010 5162 -43 ®24' 04. W (2)1.11LT10.145' PM TO (E) 0= CO t (2) +8 SCREE TO 8U JOIST 6' OVERHANG 4 4 4 � d 800 SI62 -43 BLK6. EXISTING CONCRETE 800 5162 -43 w/ HILTI 0.145" 4t PINS a 12" oz,. NOTE: REMOVE TILLS MGM TREAD EEFOW ANGHORINS TREATED PLATEa. 400 SI62 -45 WEB STIFFFNER r4/ (2) 418 SCREWS TOP 4 BOTTOM JOIST SUPPORT (4D vE3 STIFFENER I •• = 11_ 11 5O4OPJO01045 cv / 11 SCALE: 14" = 1' -0" 3' -6" FLOOR PLAN 4 -T1.1 1I' -8" ENTRY T-10" EXIS 10' -4" 33' -11" ING COLUMN DINING 4ALL 5 800 5162 -43 LEDGER (2) 800 5162 -43 BACK -TO -BACK STL. JOISTS * 48" O.G. - TYP. (UN.) EXIST1NCs STAIRS TO REMAIN - REMOVE EXIST IM TILES c24TREADS 800 S162-43 LEDGER (T'YP.) - SEE E/T -1.1 1' -0" 12' -10" LOBBY T -1.1 ECEPTION 4' -10" COLD- FORMED STEEL FLOOR FRAMING NOTES 1. ATTACH DECK TO JOISTS 11TH #8 SCREWS AT 12"0C (UNO). rNELDED MIRE FABRIC 6 x 6 — IN1.4 x TO BE USED IN ALL SLABS. 2, ALL MEMBERS ARE TO BE UNPUNCHED, 3. SCREIAIS SHALL BE SELF—DRILLING. MINIMUM EDGE DISTANCE AND C.C. SPACING TO BE 4. BRIDGE ALL STUDS AND JOISTS PER MANUFACTURER'S RECOMMENDAI1ONS. 5. SEE THE GENERAL NOTES FOR ADDITIONAL INFORMATION. 11' -6" T -lei Sm. WOJRK AREA T -1.1 6 ' 0 11 9 7?+ r f'" q' � • I r po 7- 300 AUG 10 2007 p,'•_:RMl r GEN 1E 1 PIRSCHER ARCHITECTS CPA + Ptrscher ArGhttach% 14500 Ballhger Way le, Suite 200 Saattla, Yinahington 48155 (206}36 -1 668 Fez< (206368 -4556 SHEET: T--= a I OF: SHEETS FLOOR PLAN CURVE TABLE CURVE RADIUS LENGTH DELTA CHORD Cl (C) 109850 442.68 23'05'21" N30'02'514 439.69 C1(D,R1) 1098.50 44,162 2308'19" C2 1148.50 68.127 34'05'12" N15•830 "W 673.24 C3 1198.50 461.91 22V4'55" N28 4425 "W 459.05 C4 955.24 J52.51 210$ 38" N25 27'52 "W 350.51 F0. 2" B.D. /PUNCH PER (R1); HELD rn U.v..(2)(0.1'E /O P.L -) F.P. SN. ' 7200 1561H STREET FOUR STORY BUILDING ` AREA = 15,859 SQ.FT. HEIGHT = 43' ± 0 D - may_ A.C. PVM'T 13 P. S. 0 EBOX SL.P.B U.V. 135 W. V. F -H• S.P -B• E. CAB - r S.P.B. T.S.P. m 0 N08V4■8 "ry 1 , s_s6'�c� I SOUTH 15671-1 STREET CD N88V4 43 "W 368.81(D,RI) • (60' DEDICATED PUBLIC RIGHT - OF -WAY) 1 U GE SQE��. \ 4Q�a so` „ a m `E -- q - � - - 1 Ui \ 0 P.D.C. PER TITLE LEGA1 -.-. FD. 5/8” Y.P.C. EMERALD 30581" PER (Rl); HELD FD. 2" B.D. /PUNCH PER (R7); HELD - �--- • ---� ' ' '�` N8708'08'E 398.71'(R1) • N87 04 27"E 398.69'(M) SOUTH 158TH STREET (0 I 11 i SCALE 1" FD. 2" B.D. /PUNCH PER (R1) ;; HELD 1ERRAL'ra MARK 1. 111E LOCATION OF UTILITIES SERVING THE SUBJECT PROPERTY CAN ONLY BE DETERMINED BY OBSERVED EVIDENCE TOGETHER WITH PLANS AND MARKINGS PROVIDED BY CLIENT UTILITY COMPANIES, AND OTHER APPROPRIATE SOURCES. THE LOCATION OF UTILITIES EXISTING ON OR SERVING THE SURVEYED PROPERTY FOR THIS SURVEY WAS DETERMINED BY OBSERVATION OF ABOVE GROUND EVIDENCE. 2. THE BUILDING FOOTINGS WERE NOT EASILY ACCESSIBLE AND THEREFORE THE BUILDING OMITS SHOWN HEREON, AND THE BUILDING SQUARE FOOT CALCULATIONS, WERE MEASURED ALONG THE BUILDING FASCIA. .3. ITEM NUMBERS SHOWN HEREON ARE STATED AS MATTERS ON REFERENCED COMMITMENT. NO RESPONSIBILITY FOR THE COMPLETENESS, ACCURACY, OR CONTENT OF SAID REPORT IS ASSUMED BY THIS MAP. 4. THE SUBJECT PARCEL IS LANDSCAPED WITH TREES /SHRUBS. THIS SURVEY REFLECTS MEASUREMENTS OF HARDSCAPE ONLY AND THEREFORE LANDSCAPING, LANDSCAPE LIGHTING AND IRRIGATION SYSTEMS ARE NOT SHOWN HEREON. ACCORDING 10 THE CITY OF TUKWILA ON 05/22/2007, THE SUBJECT PROPERTY IS ZONED "TUC" (TUKWILA URBAN CENTER DISTRICT) AND IS SUBJECT TO THE FOLLOWING CONDITIONS: HEIGHT RESTRICTION: LOT COVERAGE: FRONT SETBACK: SIDE SETBACK: REAR SETBACK: PARKING RESTRICTIONS: HOTELS AND MOTELS: L X/S 11NG P RKING' REGULAR PARKING: 148 SPACES LHANQICAPKING.• 4 SPAf'F, TOTAL PARKING: 152 SPACES BECAUSE THERE MAY BE A NEED FOR INTERPRETATION OF THE APPLICABLE ZONING CODES, WE REFER YOU TO THE CITY OF TUK11ILA, AND THE APPLICABLE ZONING CODES. B.D. B.S.W B. W. (C) C.L. C. O. CNC. 0.1. (D) E. BOX E. CAB. E.P. E/O F.H. F.P. FD. G.M. G.P. L R. L.P. BRASS DISC BACK OF SIDEWALK BLOCK WALL CALCULATED CENTERLINE CENTERLINE CLEAN OUT CONCRETE DRAIN INLET DEED EAST ELECTRIC BOX ELECTRIC CABINET EDGE OF PAVEMENT EAST OF FIRE HYDRANT FLAG POLE FOUND GAS METER GUARD POST IRON ROD LIGHT POLE fl FD. 1/2" Y.P.C. "PLS 29282" PER (RI); HELD 115' NONE 15' 10' 10' ONE SPACE /ROOM ONE EMPLOYEE SPACE /20 ROOMS M.B. (A4) N/0 NE /0 O.H. P.L. P.S. R.P.C. (R1) S S.D.M.H. S.L.P.B. S.M.H. 5/0 SN. 5W /0 T.S.P. T. S.P.B. TEL U.V. W LEGEND MONUMENT BOX MEASURED NORTH NORTH OF NORTHEAST OF OVERHANG PROPERTY UNE PARKING SPACE RED PLASTIC CAP RS 8911299010 SOUTH STORM DRAIN MANHOLE STREET LIGHT PULLBOX SEWER MANHOLE SOUTH OF SIGN SOUTHWEST OF TRAFFIC SIGNAL POLE TRAFFIC SIGNAL PULLBOX TELEPHONE PEDESTAL UTILITY VAULT WEST W.F. W.M. W.V. W/0 Y.P.C. --n E // ;;?,t SEE 1 8 Ail' Citi Of BUILDING DIViSic `ti WOOD FENCE WATER METER WATER VALVE WEST OF YELLOW PLASTIC CAP BLOCK /CONCRETE WALL CONCRETE EDGE OF PAVEMENT BUILDING LINE HANDICAP PARKING CHAIN LINK FENCE WOOD FENCE IRON FENCE LIGHT POLE OVERHEAD WIRE THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WEST VALLEY HIGHWAY AS SHOWN ON A RECORD OF SURVEY FILED AS RS NO. 8911299010, IN THE KING COUNTY SURVEYOR'S OFFICE, STATE OF WASHINGTON BEING NORTH 074133" WEST STATEMENT OF ENCROACHMENTS THIS LIST DOES NOT CONSTITUTE A LIST OF ALL ENCROACHMENTS. ADDITIONAL ENCROACHMENTS MAY BE FOUND BY A MAP REVIEW. aA - WOOD FENCE ENCROACHES UP 0.9' NORTHEASTERLY INTO THE FORMER SEATTLE AND TACOMA PEE RAILROAD RIGHT OF WAY. 0- CONCRETE SIDEWALK ENCROACHES UP TO 0.4' NORTHERLY INTO THE SUBJECT PROPERTY. FLOOD NOTE THE SUBJECT PROPERTY LIES WITHIN ZONE X" OF THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 53033C0978F, WHICH BEARS AN EFFECTIVE DATE OF MAY 16, 1995. ZONE X" IS DEFINED AS: AREAS OF .500 YEAR FLOOD; AREAS OF 100 YEAR FLOOD 411T -I AVERAGE DEPTHS OF LESS THAN 1 FOOT, OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MILE; AREAS PROTECTED BY LEVEES FROM 100 YEAR FLOOD. VICINITY MAP SCALE: NONE THAT PORTION OF GOVERNMENT LOTS 8 AND 10 IN THE SOUTHWEST QUARTER OF SECTION 24, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: COMMENCING AT THE INTERSECTION OF THE NORTHERLY MARGIN OF SOUTH 158TH STREET, ACCORDING TO THE Y LINE RIGHT -OF -WAY OF PRIMARY STATE HIGHWAY Na 1, GREEN RIVER INTERCHANGE, AS CONVEYED TO THE CI TY OF TUKWILA BY QUIT CLAIM DEED RECORDED MAY 28, 1980 - UNDER KING COUNTY RECORDING NO. 8005280642 WITH 7NE EASTERLY MARGIN OF SAID PRIMARY STATE HIGHWAY NO. 1, THE WEST VALLEY HIGHWAY, AS ESTABLISHED 72 FEET EASTERLY, AS MEASURED AT RIGHT ANGLES, OF THE 2M LINE THEREOF; THENCE NORTH 07'41'33" WEST ALONG SAID EASTERLY MARGIN 563.24 FEET TO AN INTERSECTION WITH A UNE "A" DRAWN PARALLEL WITH AND 55.28 FEET SOUTHERLY, AS MEASURED AT RIGHT ANGLES, OF THE NORTHERLY LINE OF DONATION LAND CLAIM NO. 46 OF THE HEIRS AT LAW OF HENRY MEADER, DECEASED; THENCE CONTINUING NORTH 074133' WEST ALONG SAID EASTERLY MARGIN 60.85 FEET TO AN INTERSECTION WITH A LINE B" DRAWN PARALLEL WITH AND 60.00 FEET NORTH OF SAID UNE "A' AS MEASURED AT RIGHT ANGLES THERETO, AND THE TRUE POINT OF BEGINNING; THENCE CONTINUING NORTH 07'41'33" WEST ALONG SAID EASTERLY MARGIN 289.73 FEET TO THE SOUTHERLY MARGIN OF PRIMARY STATE HIGHWAY Na 1, JUNCTION STATE SECONDARY HIGHWAY Na 2M TO JUNCTION PRIMARY STATE HIGHWAY NO. 2 IN RENTON; THENCE NORTH 667929" EAST ALONG SAID SOUTHERLY MARGIN 203.66 FEET TO A POINT ON THE WESTERLY MARGIN OF THE RIGHT-OF-WAY OF 77IE SEATTLE AND TACOMA PUGET SOUND ELECTRIC RAILROAD; THENCE SOUTHEASTERLY ALONG SAID MARGIN IN A CURVE TO THE RIGHT, WHOSE CENTER BEARS SOUTH 4820'51" WEST 1098.50 FEET FROM SAID POINT, THROUGH A CENTRAL ANGLE OF 23'08'19" AN ARC DISTANCE OF 443.62 FEET TO A POINT ON SAID UNE "B"; THENCE NORTH 8804'43" WEST ALONG SAID LINE "5" 368.81 FEET TO THE TRUE POINT OF BEGINNING. THE LEGAL DESCRIPTION SHOWN ABOVE DESCRIBES ALL THAT PROPERTY IN THE PRELIMINARY TITLE REPORT IDEN77FIED AS FIRST AMERICAN 1111E INSURANCE COMPANY', ORDER NUMBER NC5- 293687 -BOY, WITH AN EFFECTIVE DATE OF APRIL 23, 200Z NOTES CORRESPONDING ,TO SCHEDUL FIRST AMERICAN T7TLE COMPANY OF IDAHO: 7311 POTOMAC DRIVE, BOISE, ID 83704 ORDER NO: NCS - 293687 - --BO1; COMMITMENT DATE: APRIL 23, 2007; CONTACT. name (208)375 -0700 THE FOLLOWING SURVEY RELATED ITEMS WERE FOUND IN SAID TITLE REPORT AND ARE REFERENCED ON THIS MAP. u 4 11 1121 X13 14 20 AN EASEMENT FOR WATER PIPELINE PURPOSES RECORDED MAY 13, 1905 UNDER RECORDING NO. 337825. SAID ITEM DOES NOT DESCRIBE A SPECIFIC EASEMENT LOCA770N. WE ARE THEREFORE UNABLE TO DETERMEINE IF /HOW SAID ITEM AFFECTS THE SUBJECT PROPERTY; AND IT IS THEREFORE NOT SHOWN HEREON. RELINQUISHMENT OF RIGHTS AND STATE HIGHWAY ACCESS RECORDED DECEMBER 7, 1962 AS RECORDING NO. 5516658. SAID ITEM IS ILLEGIBLE. WE ARE THEREFORE UNABLE TO DETERMINE IF /HOW SAID ITEM AFFECTS 7HE SUBJECT PROPERTY. RELINQUISHMENT OF RIGHTS AND STATE HIGHWAY ACCESS RECORDED DECEMBER 7, 1962 AS RECORDING NO. 5516659. SAID ITEM IS ILLEGIBLE. WE ARE THEREFORE, UNABLE TO DETERMINE IF /HOW SAID ITEM AFFECTS THE SUBJECT PROPERTY. f 5 I CONDEMNATION OF RIGHTS RECORDED JANUARY 15, 1963, CAUSE NO. 596061. SAID ITEM WAS NOT PROVIDED TO OUR OFFICE. WE ARE THEREFORE UNABLE 70 DETERMINE IF/HOW SAID ITEM AFFECTS THE SUBJECT PROPERTY. RELINQUISHMENT OF RIGHTS AND STATE HIGHWAY ACCESS RECORDED MAY 20, 1963 AS RECORDING NO. 5558438. SAID ITEM IS BLANKET IN NATURE AFFECTING THE SUBJECT PROPERTY AND IS THEREFORE NOT SHOWN HEREON. Fl RELINQUISHMENT OF RIGHTS AND STATE HIGHWAY ACCESS RECORDED DECEMBER 31, 1964 AS RECORDING NO. 5828225. SAID ITEM IS BLANKET IN NATURE AFFECTING THE SUBJECT PROPERTY AND IS THEREFORE NOT SHOWN HEREON. F T1 REUNQUISHMENT OF RIGHTS AND STATE HIGHWAY ACCESS RECORDED APRIL 21, 1989 AS RECORDING NO. 8904211033. SAID ITEM IS BLANKET IN NATURE Af1EC11NG THE SUBJECT PROPERTY AND IS THEREFORE NOT SHOWN HEREON. TO AN EASEMENT FOR SEWER PURPOSES RECORDED MAY 4, 1,4 AS RECORDING NO. 8905040544. SAID ITEM AFFECTS THE SUBJECT PROPERTY AND IS SHOWN HEREON. AN EASEMENT FOR INGRESS AND EGRESS PURPOSES RECORDED MAY 4, 1989 AS RECORDING NO. 8905040545. SAID ITEM AFFECTS THE PROPERTY AND IS SHOWN HEREON. AN AGREEMENT FOR RIGHT OF ENTRY PURPOSES RECORDED NOVEMBER 28, 1989 AS RECORDING NO. 8911280641. SAID ITEM IS BLANKET IN NATURE AFFECTING THE SUBJECT PROPERTY AND IS THEREFORE NOT SHOWN HEREON. CONDITIONS AND EASEMENTS RECORDED NOVEMBER 29, 1989 AS RECORDING NO. 8911299010. SAID ITEM IS BLANKET IN NATURE AFFECTING THE SUBJECT PROPERTY. SAID ITEM CONTAINS THE FOLLOWING EASEMENTS 117 ARE SHOWN HEREON. 13A 15' EASEMENT FOR SEWER PURPOSES. EASEMENT FOR INGRESS /EGRESS PURPOSES. AN EASEMENT FOR ELECTRIC PURPOSES RECORDED FEBRUARY 12, 1990 AS RECORDING NO. 9002120762. SAID ITEM AFFECTS THE SUBJECT PROPERTY AND IS SHOWN HEREON. AN EASEMENT FOR BROADBAND SERVICE PURPOSES RECORDED MAY 8, 2002 AS RECORDING NO. 20020508000167. SAID ITEM IS BLANKET IN NATURE AFFECTING THE SUBJECT PROPERTY AND IS THEREFORE NOT SHOWN HEREON. 138 THE LAND AREA OF THE SUBJECT PROPERTY IS 103,408 SQ. F1 (2.37 •ACRES) AS DESCRIBED IN THE LEGAL DESCRIPTION SHOWN HEREON. THE UNDERSIGNED HEREBY CERTIFIES, AS OF JUNE 5, 200Z TO WACHOVIA BANK, NAAONAL ASSOCIATION AND ITS SUCCESSORS AND ASSIGNS, TUKWILA HOTEL, LLC, A DELAWARE LIMITED UABIUTY COMPANY AND FIRST AMERICAN TITLE INSURANCE COMPANY THAT HE IS A DULY REGISTERED LAND SURVEYOR OF THE STATE OF WASHINGTON; THAT 17-/IS PLAT OF SURVEY IS MADE AT LEAST IN ACCORDANCE WITH THE MINIMUM STANDARDS ESTABLISHED BY SAID STATE FOR SURVEYS AND LAND SURVEYORS AND WITH THE MINIMUM DETAIL REQUIREMENTS FOR LAND TITLE SURVEYS AS ADOPTED BY THE AMERICAN LAND T71LE ASSOCIAEON AND AMERICAN CONGRESS ON SURVEYING AND MAPPING; THAT THIS SURVEY CORRECTLY SHOWS THE LOCATION OF ALL BUILDINGS, STRUCTURES AND OTHER IMPROVEMENTS SITUATED! ON THE SUBJECT PREMISES; AND THAT EXCEPT AS SHOWN, THERE ARE NO VISIBLE EASEMENTS OR RIGHTS OF WAY ACROSS SAID PREMISES OR ANY OTHER EASEMENTS OR RIGHTS OF WAY OF WHICH THE UNDERSIGNED HAS BEEN ADVISED, NO PARTY WALLS, NO ENCROACHMENTS ONTO ADJOINING PREMISES, STREETS OR ALLEYS BY ANY OF SAID BUILDINGS, STRUCTURES OR OTHER IMPROVEMENTS, AND NO ENCROACHMENTS ONTO SAID PREMISES BY BUILDINGS. STRUCTURES OR OTHER IMPROVEMENTS SITUATED ON ADJOINING PREMISES. REGISTRATION N0. 40017 WITHIN THE STATE OF WASHINGTON DATE OF SURVEY: MAY 25, 2007 DA 7E OF REV 1: MICHAEL A. HO FMANN, P.L.S. 40017 EXP: OCTOBER 22, 2008 MIKEHgTERRAMARK /NC. COM TERRAMARK DATE : 05 -31 -07 SCALE : 1" = 40' r /. 213 SOUTH MAIN STREET, MOSCOW, IDAHO 83843 PH: 208/882 -7788 FX: 208/882-77801 I DRAWN BY JLP CHKD BY BCO Leis 7 PATE L TA /AGSM LA T1TL SVR6 E1 • TUKWILA HOTEL, LLC RECEIVEr . 7200 S 156711 STREET AUG 1 0 ZUU SEATTLE, WA ChNi JOB NO: 2007879 SHEET: 1 OF 1 Da 300