Loading...
HomeMy WebLinkAboutPermit D07-313 - LEGACY PARTNERS - WALL DEMOLITIONLEGACY PARTNERS 16400 SOUTHCENTER PY SUITE 407 D07 -313 Parcel No.: 2623049021 Address: 16400 SOUTHCENTER PY TUKW Suite No: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: LEGACY PARTNERS Address: 16400 SOUTHCENTER PY, STE 407 , TUKW LA WA Owner: Name: LEGACY PARTNERS I TUICWILA L Address: 10655 NE 4TH ST #812 , BELLEVUE WA 98004 Phone: Contact Person: Name: JENNIE WHITAKER Address: 10230 NE POINTS DR, STE 300 , K RKLAND WA 98033 Phone: 425 827 -2100 Contractor: Name: GATEWAY CONSTRUCTION SRVCS INC. Address: 701 DEXTER AVE N SUITE 420 , SEATTLE WA 98109 Phone: (206)621 -9111 Contractor License No: CATEWCS992C3 doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D07 -313 Issue Date: 01/18/2008 Permit Expires On: 07/16/2008 Expiration Date: 03/04/2008 DESCRIPTION OF WORK: DEMOLISH EXISTING "WING- WALL" CONSTRUCTION, PATCH AND REPAIR WITH NEW FINISHES. Value of Construction: $10,000.00 Fees Collected: $375.06 Type of Fire Protection: SPINKLERS International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 0008 D07 -313 Printed: 01 -18 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Main Extension: Water Meter: N Permit Center Authorized Signature: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D07 -313 Issue Date: 01/18/2008 Permit Expires On: 07/16/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Thee: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Thee: End Thee: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Private: Public: Date: , (U -- v } I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of ermit does not presume, j ve authority to violate or cancel the provisions of any other state or local laws regulating construction'or the • erformance ; f ork. Signatur Print Nam doc: IBC orized to sign and obtain this developmenntermit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -313 Printed: 01 -18 -2008 Parcel No.: 2623049021 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16400 SOUTBCENTER PY TUKW LEGACY PARTNERS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -313 ISSUED 08/20/2007 01/18/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or .granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) doc: Cond -10/06 D07 -313 Printed: 01 -18 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than S feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 24: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051.(Install audibility and visibility throughout the space.) 26: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this doc: Cond -10/06 D07 -313 Printed: 01 -18 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** project. 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 30: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 31: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D07 -313 Printed: 01 - 18 - 2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the • - rformance of work. Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us /4 g7t2.. Date: ( 7/ 670 s D07 -313 Printed: 01 -18 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us King Co Assessor's Tax No.: 21.02.304 02./ / Site Address: 11.041 t Sr i Yf 1( Suite Number: 4b 7 Floor: 4 New Tenant: ❑ Yes ❑..No Tenant Name: -'- Property Owners Name: L.Ef r! q T .e. C/711 Ail Ac-4r--C 1 A Mailing Address: 4 o A-vE_ rrvirEe. Ca Ty City CONTACT PERSON - who do we contact when your permit is ready to be issued Name:J F.;4P4% L11- 41 E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Day Telephone: 1 1Z - nZ q -2I Mailing Address: l 02.f) 1.1 E `POI LtT5 D g. ; tre- -arr) /V 14-7.1i> WA 98c33 City State Zip E -Mail Address:3l. 4(0f ar' Arch • WYY) Fax Number: 425 - S2,g3 4089 / GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: r. ` l3. . Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: ' F Q . F i t 1 p 7 . 4 1 - 4 4. pin jarre_al T LT S IN r.. f 1 ?,, . s • II /► Mailing Address: lf)L?r, NC ' 1?o1.t1S'� S Kl Y LAN 0 L(H 98C33 1 City State Zip Day Telephone: '/2.5 - 0V7 -7.1 CD Fax Number: /Z - SZS-643 Contact Personir Kitt t.t ENGINEER r F RECORD - All plans must be wet stamped by Engineer of Record Q:Upplications\Fams- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh s om- Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) CA 94414 State Zip Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 BUILDING PERMIT INFORITION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ I0 Existing Building Valuation: $ !O CF3q 7/10 Scope of Work (please provide detailed information): ' P P c - C G a & ' c k 2 4 '61Q 1 s - . Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: pi Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Saf Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line\ -2006 - Permit Applicationdoc Revised 9 -2006 bh . "71 .. No If yes, a separate permit and plan submittal will be required. Floor area of accessory dwelling: Compact: Handicap: Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1` Floor 11 11-5 5 2" Floor l3, 74 I I 3 ,d Floor I3, 774 11-B T) Floors i4 tiro 5 I3 1 774 /, 3`_, I I - ?) Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORITION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ I0 Existing Building Valuation: $ !O CF3q 7/10 Scope of Work (please provide detailed information): ' P P c - C G a & ' c k 2 4 '61Q 1 s - . Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: pi Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Saf Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line\ -2006 - Permit Applicationdoc Revised 9 -2006 bh . "71 .. No If yes, a separate permit and plan submittal will be required. Floor area of accessory dwelling: Compact: Handicap: Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Mailing Address: 102 3b Or. T n.11 — Oz. 5E Date Application Accepted: Ioi- Q\Applications\Fonns-Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh ay Telephone: 4 kut urn City Date Application Expires: a Date: 8 1(nl07 {{ q -2(00 State 9 Zip Staff Initials: Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049021 Permit Number: D07 -313 Address: 16400 SOUTHCENTER PY TU1CW Status: APPROVED Suite No: Applied Date: 08/20/2007 Applicant: LEGACY PARTNERS Issue Date: Receipt No.: R08 -00174 Initials: WER User ID: 1655 Payee: JAN GREENE TRANSACTION LIST: Type Method Description Amount Payment Check 8339 229.08 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 224.58 000/386.904 4.50 Total: $229.08 Payment Amount: $229.08 Payment Date: 01/18/2008 09:00 AM Balance: $0.00 7428 01/18 9710 TOTAL 631.76 doer Raraint -(1R Printarl• (11- 1R -2f(1R Receipt No.: R07 -01750 Initials: JEM User ID: 1165 Payee: LEGACY PARTNERS ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES �,r v City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049021 Permit Number: D07 -313 Address: 16400 SOUTHCENTER PY TUICW Status: PENDING Suite No: Applied Date: 08/20/2007 Applicant: LEGACY PARTNERS Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 1352 145.98 Account Code Current Pmts 000/345.830 145.98 Total: $145.98 Payment Amount: $145.98 Payment Date: 08/20/2007 03:35 PM Balance: $229.08 1862 08/21 9710 TOTAL 145.98 doc: Receiot -06 Printed: 08 -20 -2007 Pro+ect: Le ce q P A e+ Net/C..... Co A Type of Inspection: ' i ,U-,q Address: 1 - (O C, C at-I Gr±,Jte- Date ailed: r ` Special Instructions: Date Wanted: BF ,rtt- Requester: Phone No INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION YL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: pe Inspecto(L U 1 Date: 7 , El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: ,Date: Approved per applicable codes. ❑ Corrections required prior to approval. Projec • ,fie 9 .wyP4, /,v€'/ Type Inspection: 5, -,v o �y /.i. Address: // Vet F•t/ iA ate Called: Special Instructions: ��' � ,f J /� 0 _ �1 . `\ ,9 4 0a Date Wanted: O 7— �5 — '= p.m. Requester: Phone No: -563 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r C _S P' : , PJ L - <..� r r ,i.,. r 'Inspecto j (Date: _ + J �� ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: PERMIT NO. COMMENTS. Type of Inspecyon: rye A,A , Addres : r � I .S .c. pAJ 1 7 - 7,.J Date Called: ED Sc(c (3 ()F ( (..\`Al �T � I`� r 116f,t, A P/ ( S,/'‘_ ,1- f - t 8 Project: A z p a r�l els Type of Inspecyon: rye A,A , Addres : r � I .S .c. pAJ 1 7 - 7,.J Date Called: i Special Instructions: i te Wanted: " 14 _3 a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Inspectoy' 009 -3( orrectio required prior to approval. f Date r - 7 — / n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: J J t Project: Sou 4-11c e, r t«- "act- Type of Inspection: , • ,4 0/44 ,� C%IG Address: / 1/ov Suite #: y v 7 sc Piewr Contact Person: a 14 oeL s ‘v� 'cam_ Special Instructions: Permits: Phone No.: ' -G 70 - 54 se Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER F Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT OP7 -313 OR - P- 3 PERMIT NUMBERS Wa. 98188 206- 575 -4407 COMMENTS: Inspector: 54) s Date: e � j , Hrs.: f • $80.00 REINSPECTION FEE REQUIRED: You will receive an invoice from City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 Li Corrections required prior to approval. T.F.D. Form F.P. 113 Project: Sl >n�.- --d` \ _. " OA( c Fire Alarm: Type of Inspection: Ceti-e dL Monitor: Address: A, q00 Suite #: C- e_ • rz / Contact Person: C6.2frS Cox >,Qe_r, Special Instructions: Phone No.: ( -f) c .6)e - s 6 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 41 4Pproved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Word /Inspection Record Form.Doc 1/13/06 Date: 7/ 51 Do -313 ox— s- ?s PERMIT NUMBERS Corrections required prior to approval. COMMENTS: Or_ Cu yo ° - 1� -/ 0 0 Inspector: 'Art S /V Hrs.: / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. T.F.D. Form F.P. 113 ti COMMENTS: Ol dl { Type of Inspection: Cove_ it_ Address: / b i-f 0 O Suite #: La7 5. C. r 1 i Contact Person: c li j e Special Instructions: . /96/) iig,y 42, re. „.) N. q -Cce P, 1 4 D /: nl) U .0 /r ti , (f' - I D ,4I/ /✓ N!h J! Jr'_..) 9- C ` • / / 2 i .) L. , J C' , I'LL - ,w : /z Sn -e'� ei,., / b(J V" ,k.c1C, J /g) pe, ll !J t o vP I v-( pm ry s Project: S (z z--( y` c _ Q,,L Ol dl { Type of Inspection: Cove_ it_ Address: / b i-f 0 O Suite #: La7 5. C. r 1 i Contact Person: c li j e Special Instructions: Phone No.: u2 S > 9S — %5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT p0 - 7 — 3/3 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 n Approved per applicable codes. rrections required prior to approval. I Inspector: SR/ Date: 44) (0 5 Hrs.: / �„L n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from / the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address 16400 SOUTHCSt1TER PARKWAY Date 8/20/2007 TUKWILA, WASHINGTON For Building Department Use FILE COPY ' q1: 1 Area in ft (or If for perimeter) Applicant Name: Preiheit and Ho Architects, Inc., P.S. ApplicantAddress: 10230 NE POINTS DRIVE STE 300 KIRKLAND, WA 98033 Covered Parking (standard paint) ' Applicant Phone: 425.827.2100 P Project Description ❑ Plans Induded requirements. ❑ New Building ❑ Addition -' {+Iteration Refer to WSEC Section 1513 for controls avid commissioning Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) 0'3 W /ftz Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Open Parking & space use not changed. -' Less than 60% of the fixtures new, installed wattage not increased, Location (floor /room no.) - • Occupancy Description Allowed Watts per ft Area in ft Allowed x Area Area in ft (or If for perimeter) Allowed Watts x ft (or x If) REMIEWED FOR Covered Parking (standard paint) COUt COMPLIANCE !f � �� 112 0.2 W/ft Covered Parking (reflective paint) Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts 0'3 W /ftz ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts RECEIVED OF TUKWII A Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Area in ft (or If for perimeter) Allowed Watts x ft (or x If) REMIEWED FOR Covered Parking (standard paint) COUt COMPLIANCE !f � �� 112 0.2 W/ft Covered Parking (reflective paint) Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts 0'3 W /ftz CITY RECEIVED OF TUKWII A Open Parking AUG 2 8 7007 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 0.2 W /ft2 Location Fixture Description Number of Watts/ Fixtures Fixture Watts Proposed Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x If) REMIEWED FOR Covered Parking (standard paint) COUt COMPLIANCE !f � �� 112 0.2 W/ft Covered Parking (reflective paint) Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts 0'3 W /ftz CITY RECEIVED OF TUKWII A Open Parking AUG 2 8 7007 0.2 W /ft2 AUG 2 0 2007 Outdoor Areas /!1/ VVIICCC"'��" 0.2 W/ft MI i C;tNTER Bldg. (by facade)' O T i ty f ukwla 0.25 W /ft2 PEF Bldg. (by perim) 7.5 W/If 1. Choose either the facade area or _._ Total Allowed Watts Location Fixture Description Number of Watts/ Fixtures Fixture Watts Proposed Er)04 i 112 Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts F hting Summary LTG -SUM 2004 Washington State Nonresidential Energy Code Compliance Forms 2004 Washington State Nonresidential Energy Code Compliance Form Maximum Allowed Lighting Wattage (Interior Revised May 2005 Proposed Lighting Wattage (Interior) Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 3. List all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior se mtgr listed maximum input wattage. for fixtures wutn hart -wlrea oalrasrs only, Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. Use' LPA` (W /sf) Use' LPA` (W /sf) Painting, welding, carpentry, machine shops 2.3 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools ho pitals, institutions, museums, banks, churches) ' ' 1.0 Barber shops, beauty shops 2.0 Police and fire stations" 1.0 Hotel banquet/conference/exhibition hall'' 2.0 Atria (atriums) 1.0 Laboratories 1.8 Assembly spaces ", auditoriums, gymnasia ", heaters 1.0 Aircraft repair hangars 1.5 Group R -1 common areas 1.0 Cafeterias, fast food establishments' 1.5 Process plants 1.0 Factories, workshops, handlin 1.5 Restaurants/bars' 1.0 Gas stations, auto repair shops 1.5 Locker and /or shower facilities 0.8 Institutions 1.5 Warehouses ", storage areas 0.5 Libraries' 1.5 Aircraft storage hangars 0.4 Nursing homes and hotel /motel guest rooms 1.5 Retail' retail banking 1.5 Wholesale stores (pallet rack shelving) 1.5 Parking garages (see exterior lighting) Section 1532 Mall concourses 1.4 Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Plans Submitted for Common Areas Only' Laundries 1.2 Main floor building lobbies' (except mall concourses) 1.2 Medical Offices, Clinics" 1.2 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist ed type is "Other" and fixture answer If is occupancy es in answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if all fixtures are ballasted and at least 95%* of fixtures are either: 1 . Fluorescent fixtures which a) are non - lensed. b) h ave 1 or 2 two lamps c have ) ) P ) 5-60 watt T -1, T -2, T-4, T -5, T-6, T-8 lamps. d) have hard -wired electronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts ' - Exit and LED lights can be excluded from count if < 5 watts/fixture. 1J ting Summary (back) LTG -SUM 2004 Washington State Nonresidential Energy Code Compliance Forms 2004 Washington State Nonresidential Energy Code Compliance Form Revised May 2005 TABLE 15 -1 Unit Listhtina Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) See Section 1532 for exterior lighting. 7) For conference rooms and offices Tess than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.20 w /ft may be used. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For indoor sport toumament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 12) Medical and clinical offices include those facilities which, although not providing ovemight patient care, do provide medical, dental, or psychological examination and treatment. These spaces include, but are not limited to , laboratories and treatment centers. 06 -05 -2008 JENNIE WHITAKER 10230 NE POINTS DR, STE 300 KIRKLAND WA 98033 RE: Permit No. D07 -313 16400 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writinz and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/16/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, A-4X er Marshall, Permit Technician xc: Permit File No. D07 -313 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 01 -08 -2008 JENNIE WHITAKER 10230 NE POINTS DR, STE 300 KIRKLAND WA 98033 RE: Permit Application No. D07 -313 16400 SOUTHCENTER PY TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 08/20/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 02/16/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 02/16/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall 't Technician Permit File No. D07 -313 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ti..AERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 - 313 DATE: 08 -20 -07 PROJECT NAME: LEGACY PARTNERS, STE 407 SITE ADDRESS: 16400 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bul' "IMing Division Public Works RJ Structural ❑ A_ 8- V -0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28-02 51 kV) Fire Prevention Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: 64, B 11{d Division Permit Coordinator DUE DATE: 08-21-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required ❑ DUE DATE: 09-18-07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License GATEWCS992C3 Licensee Name GATEWAY CONSTRUCTION SRVCS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602086011 Ind. Ins. Account Id 754100 Business Type CORPORATION Address 1 701 DEXTER AVE N SUITE 420 Address 2 City SEATTLE County KING State WA Zip 98109 Phone 2066219111 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/26 /2001 Expiration Date 3/4/2008 Suspend Date Separation Date Parent Company Previous License NIELSC *02708 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SACCO, RONALD PRESIDENT 02/26/2001 Bond Amount NIELSEN, CRISTIAN VICE PRESIDENT 02/26/2001 SRS1008614 Bond Information Bond Bond Company Name Bond Account Number Effective . Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 RLI INSURANCE CO SRS1008614 02/26/2002 Until Cancelled $12,000.00 03/04/2002 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= GATEWCS992C3 01/18/2008 GENERAL NOTES GENERAL NOTES: I. ALL CONSTRUCTION SHALL COMPLY WITH THE 2006 INTERNATIONAL BUILJDIN6 CODE AS ADOPTED BY THE CITY OF TUKWILA, WASHINGTON STATE REGULATIONS FOR. BARRIER FREE DESIGN, WASHINGTON STATE ENERGY CODE, AND ALL APPLICABLE LOCAL CODES, ORDINANCES, AND STANDARDS. IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED 11-I>= REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. 2. SECURE RELEVANT CITY AND STATE APPROVALS RELATING 70 FIRE, CONSTRUCTION, LABOR, HEALTH AND LICENSING. CONTRACTOR SHALL FURTHER POST ALL BONDS AND SECURE ALL INSURANCE REQUIRED BY LAW OR CONTRACT, FORWARDING PROOF OF SUCH ACTIONS TO THE LANDLORD PRIOR TO COMMENCEMENT OF CONSTRUCTION. 3. PROVIDE ALL NECESSARY PERMITS AND FEES, WITH THE EXCEPTION OF THE BUILDING PERMIT, WHICH WILL BE PROVIDED BY THE OWNER. 4. WORK NOT INCLUDED IN THIS CONTRACT SHALL BE MARKED "N.I.G." OR SPECIFICALLY ASSIGNED TO ANOTHER PARTY. 5. CONTRACTOR SHALL VISIT THE SITE, REVIEW THE DRAWINGS AS SUBMITTED BY THE ARCHITECT, AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. 6. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 1. SUBMIT A LIST OF PROPOSED PRODUCT SUBMITTALS AND SHOP DRAWINGS TO THE OWNER FOR APPROVAL PRIOR TO START OF CONSTRUCTION. 8. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT 15 INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK 10. VERIFY ALL "BUILDING STANDARDS" WITH BUILDING OWNER PRIOR TO BEGINNING ANY WORK. HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY, AND HOW THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. II. ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS (WITH EXCEPTION TO SPECIFIC FINISH COLORS AND FLOORING) ARE INTENDED TO BE ON AN OR EQUAL" BA5I5. MY PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO THE ARCHITECT IN WRITING FOR APPROVAL WITHOUT DELAY OF SCHEDULE. 12. LOCATE ALL EXISTING UTILITIES 1 THER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. Is. VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS. 14. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A GLEAN (BROOM) CONDITION AT ALL TIMES. 15. PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXPENSE. 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL APPLICABLE SAFETY CODES, 11. THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER/ARCHITECT/ENGINEER HARMLE55 FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES, OR SUBCONTRACTORS. 18. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL. AS ALL REVISIONS, ADDENDA, AND CHANGE= ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE WT OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. I4_ MAINTAIN ALL EXIT PATHWAYS DURING CONSTRUCTION. 20. PROVIDE COMPLETE SECURITY OF THE TENANT SUITE WHILE JOB 15 IN PROGRESS AND UNTIL THE JOB 15 COMPLETED. 21. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING SPACE GLEAN, WASH ALL NEW WINDOWS AND GLASS, POLISH ALL NEW OR REWORKED HARDWARE. REPLACE AND PATCH AREAS OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. 22. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (I) YEAR AFTER COMPLETION, UNLESS OTHERWISE SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE 15 GIVEN. 23. MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE, ODOR, FUMES, OR VIBRATION. AT THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY CLEAN ALL AREAS SOILED BY CONSTRUCTION ACTIVITIES INCLUDING THOSE IN WHICH NO WORK WAS ONE 24. LATHING, PLASTER, AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO THE CHAPTER 25 OF THE 2006 I.B.G. 25. U5E GYPSUM WALL BOARD METAL TRIM AT ALL CORNERS AND INTERSECTIONS; PAINT TO MATCH ADJACENT WALL. 26. ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF TIME 2006 'B.C. AND THE U.S. PRODUCT SAFETY COMMISSION: SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (42 FR 1426: 16 CFR PART 1200. 21. VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW MANUFACTURERS. 28. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWING SHOULD BE CALLED TO THE ATTENTION OF THE ARCHITECTS_ 24. REMOVE ALL ABANDONED CABLING INCLUDING VOICE AND DATA TO SOURCE. DEMOLISH EXISTING UNUSED PLATES, ALL SURFACE MOUNTED CONDUIT AND SURFACE MOUNTED JUNCTION BOXES. REPAIR WALL CONDITION TO LIKE -NEW AS REQUIRED. 30. CARE SHALL BE TAKEN DURING DEMOLITION TO PROTECT ALL CONSTRUCTION TO REMAIN. CONTRACTOR SHALL REPAIR OR REPLACE ALL DAMAGED MATERIAL TO A LIKE -NEW CONDITION. 31. PROTECT ALL AREAS OF BUILDING AND H.VAG. SYSTEM FROM DUST AND DEBRIS AT ALL TIMES. 15. THE PLANS 5140W GENERAL DEMOLITION WORK TO BE PERFORMED AND DO NOT RELIEVE THE CONTRACTOR FROM OTHER DEMOLITION WORK REQUIRED TO PRODUCE THE BUILDING MODIFICATIONS SHOWN ON THE REMAINING CONTRACT DOCUMENTS. 16. REPAIR OR REPLACE MISSING AND DAMAGED SPRINKLER ESCUTCHEON PLATES. 11. PATCH AND REPAIR GJNB. AS REQUIRED TO ACCEPT NEW FINISH. REPAINT ALL WALLS; IN SPECIFIED LOCATIONS PAINT ACCENT WALLS. IS. AFTER THE DEMOLITION OF THE EXISTING WALL BASE, FLOAT THE WALLS AS REQUIRED TO HAVE A SMOOTH SURFACE ABOVE THE NEW 2-1/2" BASE. 19. REPLACE ALL NON-BUILDING STANDARD T ERM05TATS WITH NEW, WHITE, BUILDING STANDARD THERMOSTATS. DIMENSION: I. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS 15 GIVEN AS THE 15E5T PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK 2. DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISHED G.N.B. FACE OF PARTITIONS, UNLESS NOTED OTHERWISE. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE FOUR (4) INCHES FROM THE FACE OF THE ADJACENT PARTITION OR CENTERED BETWEEN PARTITIONS. a Do NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF DISCREPANCIES ARE FOUND. CONTRACTOR SHALL CONSULT OWNER'S REPRESENTATIVE WHEN ADDRESSING QUESTIONS OF MATERIAL, METHODS, DETAIL OR WORKMANSHIP NOT COVERED IN THE CONTRACT DOCUMENTS. 4. CONSTRUCT WALLS PLUMB AND SQUARE WITH EXISTING STRUCTURE AND NEW CONSTRUCTION UNLESS NOTED OTHERWISE. 5. COORDINATION: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFIGATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS. 6. ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. GENERAL NOTES, CONT. FIRE PROTECTION: I. IF NECESSARY, PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RELATED ELEMENTS AS REQUIRED BY CODE. 2. FIRE E)CflNGUISHER5: VERIFY LOCATION, TYPE, AND SIZE PER FIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE EXTINGUISHERS REQUIRED UNDER N.F.P.A. 10 MOST REGENT EDITION AND APPROVED BY THE FIRE MARSHALL. CONFIRM ACCEPTABILITY OF LOCATION WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE FINISHED CABINETS TO MATCH BUILDING STANDARD FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. 3. FIRE EXTINGUISHERS AND CABINETS SHOULD BE LOCATED 50 THAT THE TOP OF THE EXTINGUISHER OR CABINET 15 NO HIGHER THAN 48" A.F.F. AND THE TOP OF THE EXTINGUISHER OR CABINET HANDLE 15 AT LEAST 36" A.F.F. 4. AT SEMI - RECESSED FIRE EXTINGUISHER CABINETS WRAP ADDITIONAL LAYER(5) OF TYPE 'X' GYPSUM WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT. REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. 5. PROVIDE AND INSTALL FIRE EXTINGUISHER SIGNAGE (5 "X6 ABOVE EACH FIRE EXTINGUISHER OR CABINET WITHIN THE SCOPE OF THE TENANT IMPROVEMENT. MOUNT AT 84" A.F.F. UNLESS OTHERWISE REQUIRED. 6. EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 2006 IB.C. AND TUKWILAFIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND EXIT LIGHTING AS REQUIRED BY THE CITY OF TUKWILAFIRE AND BUILDING DEPART1vENT5. CONFIRM ACCEPTABILITY OF LOCATIONS WITH OWNER'S REPRESENTATIVE BEFORE INSTALLATION. CONTRACTOR SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH IB.G. ARTICLE 4. CONTRACTOR SHALL PROVIDE AND INSTALL VISIBLE ALARM SIGNALS AS REQUIRED BY ADA GUIDELINES. CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE DETECTION AS REQUIRED UNDER ARTICLE 4 OF THE IB.G. THE INSTALLATION OF THE ABOVE NOTED SYSTEM SHALL INCLUDE THE CONNECTION TO AND /OR MODIFICATION OF THE EXISTING BUILDING SYSTEMS, AS NECESSARY. 7. EXIT DOORS SHALL BE OPENA8LE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 8. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED, OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN N.F.P.A. STANDARD 30 AND THE 2006 INTERNATIONAL FIRE CODE. PERMIT MAY BE REQUIRED. 4. ALL DRAPES, HANGINGS, CURTAINS, AND ALL OTHER DECORATIVE MATERIAL, INCLUDING CHRISTMAS TREES THAT WOULD Tao TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NONFLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE MARSHALL. PROVIDE A CERTIFICATION TO THIS EFFECT. EXIT DOORS, EXIT LIGHTS, AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONGEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER TABLE 8035, SECTION 803.1 OF THE 2006 !B.C. 10. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. CONSTRUCTION: I. INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 2. COORDINATE CONSTRUCTION SCHEDULING WITH TENANT AND BUILDING REPRESENTATIVE TO ALLOW ONGOING OPERATION OF THE FACILITY DURING CONSTRUCTION. 3. PROVIDE FIRE TREATED BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 4. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONGEALED OR FURRED AND FINISHED, UNLESS NOTED AS EXPOSED ON CONSTRUCTION DRAWINGS. 5. OFFSET STUDS WHERE REQUIRED 50 THAT FINISH WALL SURFACES WILL BE FLUSH. 6. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 'T. PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW CONSTRUCTION TO RECEIVE NEW SCHEDULED FINISHES. ALL SURFACES ARE TO HAVE "LIKE= -NEVI" APPEARANCE. PLUMBING, MECHANICAL 4 ELECTRICAL: L PLUMBING, MECHANICAL, 4 ELEGTRIGAL DRAWINGS ARE TO BE SUBMITTED UNDER SEPARATE PERMIT. 2. MECHANICAL 4 ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE TO MAINTAIN COMPLIANCE WITH APPLICABLE CODES AND STANDARDS AND OBTAIN ALL NECESSARY PERMITS AND APPROVALS. 5. ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. 4. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWING SHOULD BE GALLED TO THE ATTENTION OF THE ARCHITECTS. 5. WHERE APPLICABLE, AT ALL TENANT PLUMBING WALLS PROVIDE S 5 /8" MINIMUM METAL STUDS. CONFORM TO WALL TYPE SCHEDULE FOR SPECIFIC PARTITION HEIGHT, STUD SPACING, SPECIFIC GYPSUM WALL BOARD, AND INSTALLATION REQUIREMENTS. 6. ELECTRICAL ROUGH -IN AND REFLECTED CEILING PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR EXACT LOCATIONS SHOULD BE VERIFIED. 7. ALL CABLING AND WIRING NOT IN CONDUITS OR FULL SURROUND GABLE TRAYS SHALL HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50. 8. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE BIDDER DESIGN/ BUILD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE CORRESPONDING PERMITS FOR WORK. THE PROPOSED SYSTEM DESIGN 4 METHOD OF OPERATION FOR ALL ROOMS SHALL BE REVIEWED AND APPROVED BY THE TENANT PRIOR TO THE START OF ANY WORK. 9. WHERE APPLICABLE, STRUCTURAL, FUNDING, MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE BUILDING OWNER, TENANT, OR ARCHITECT. GENERAL FINISH NOTES: I. SUBMIT FINISH SAMPLES TO OWNER AND TENANT FOR APPROVAL PRIOR TO ORDERING MATERIALS. 2. INTERSECTION OF SCHEDULED FLOORING MATERIALS ARE TO OCCUR AT CENTERLINE OF DOOR MEN IN A FULLY CLOSED POSITION UNLESS NOTED OTHERWISE. 3. PROVIDE APPROPRIATE TRANSITION MATERIAL AS REQUIRED WHERE DISSIMILAR FLOORING MATERIALS INTERSECT. 4. PATCH 4 REPAIR ALL FLOORS, WALLS, AND CEILINGS, AS REQUIRED BY DEMOLITION AND NEW CONSTRUCTION. ALL SURFACES ARE TO BE UNIFORM AND IN LIKE -NEW CONDITION. 5. PAINT AREAS OF NEW GAB. REPAIR AND TOUGH -UP AREAS OF EXISTING DAMAGE. DO NOT REPAINT SMALL AREAS, REPAINT ENTIRE WALL LENGTH WHERE NEW WORK OCCURS. 6. PAINT ALL WALLS P -I UNLESS NOTED OTHERWISE. CEILING: I. ALL LAY -IN ACOUSTICAL CEILING GRIDS, LIGHT FIXTURES AND DIFFUSERS SHALL BE INSTALLED AND SECURED PER SECTION 805.4.1 OF THE 2006 I B.G., AND ASTM E508 -02, FOR EARTHQUAKE ZONE 111. SEE PETAL 3/A6.0. 2. CEILING HEIGHTS, WHERE INDICATED, ARE FROM FINISHED FLOOR ELEVATION TO BOTTOM OF CEILING GRID OR OTHER FINISH SURFACE. 1. SAND AND RESTAIN BOTH SIDES OF ALL EXISTING DOORS AS REQUIRED TO MATCH BUILDING STANDARD. PROJECT DATA PROJECT ADDRESS: PROJECT OWNER: PROJECT ARCHITECT: CONTRACTOR: AUTHORITY: GOVERNING CODE: ZONING: OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: PROPERTY TAX NO.: SQ. FT. OF IMPROVEMENT: 50. FT. OF BUILDING: VALUATION: 16400 SOUTHCENTER PARKWAY TUKWILA, WA 48188 LEGACY PARTNERS 4000 E 3RD AVENUE FOSTER CITY, CALIFORNIA 94404 CONTACT: EDWARD NAZARADEH FREIHEIT 4 HO ARCHITECTS, INC. P.5. 10230 NE POINTS DRIVE, SUITE 500 KIRKLAND, WASHINGTON 48055 PHONE (425) 521-2100 FAX: (425) 828 -6849 CONTACT: JENNIE WHITAKER TO BE DETERMINED CITY OF TUKWILA 2006 IBC AS ADOPTED BY THE CITY OF TUKWILA COMMERCIAL B OFFICE I I -B 2625044021 1,550 5.F. 66,455 5.F. $10,000 KEY PLAN DRAWING INDEX A0.0 GENERAL NOTES, LEGAL DESCRIPTION, PROJECT DATA, DRAWING INDEX, KEY PLAN A3.0 FLOOR FLAN, REFLECTED CEILING PLAN, FINISH SCHEDULE A6.0 TYPICAL WALL AND CEILING DETAILS LEGAL DESCRIPTION 262504 21 PARCEL I OF CITY OF TUKWILA REVISED SHORT PLAT *'T -51 -55 AKA BLA #3-74 REC V1404150561 SD PLAT OAF - POR 5E 1/4 OF NW 1/4 BEG AT MONUMENTAL INTSN OF CA- OF SOUTHCENTER PARKWAY 51TH AVE 5 4 STRANDER BLVD S 164TH 5T TH 5 8-45 -5 E 375.05 FT TH 5 0 -25.58 E 30 FT TO AN INTSN WITH 5 MGN 5D STRANDER BLVD 4 TPOB TH CONTG 5 0 -25-55 E 200 FT TH 584 -45-58 E 550 FT TH 5 0 -25-58 E 104520 FT TH N 84 -45 -I1 W 626.51 FT TO E M&N SOUTHCENTER PARKWAY TH N 0 -51 -48 W 1241.55 FT TO A PT OF CURVE TH NLY 4 ELY ALES ARC OF CURVE TO REST RAD 50 FT THRU C/A 41 -11-50 19.53 FT TO 5 MGN STRANDER BLVD TH 5 84 -45-55 E 257.12 FT TO TPOB LESS POR OF SD PAR I FOR 5T UNDER REC NO 8510250422 FILE CCIPT Permit No. Han review c- ~70va1 Is subject to errors and omission, Approval c; c_::_:. Lotion documents does not authorize the violation " __/ . ��� code cr ordinanc"e. Remipt of approv ;E r4... J c; 4: 1 ^ ^ : - J admol Jvledged° BY City of Tukwila \ BUILDING DIVLSION SEPARATE PERMIT REQUIRED FOR: Matinanicsi VElectrical wif Plumbing eGas Piping City of Tukwila BI.E" n+ iC DIVISION AREA UNDER PERMIT FIRST FLOOR - NOT TO SCALE REVIEWED FOR CODE COMPLIANCE APPP.a. 'VE AUG 2 8 2001 Of Tukwila IN DIVISION RECEIVED CIN OF TUKWILA AUG 20 2007 • 4:, VC1 - *313 fL tte ss1 - ) mange of l' up idDevisi f e and Y CONSTRUCTION DOCUMENTS FOR LEGACY SOUTHCENTER PARKWAY SUITE 407 TENANT IMPROVEMENT 16400 Southcenter Parkway Tukwila, WA 98188 ISIONS PERMIT 4 BID SET REGISTRATION FREIHEIT & HO ARCHITECTS INC., P.S. 10940 NE 33RD RACE SURE 202 BELLEVUE, WA 98004 P:425.8272100 F:425.82&6899 DRAWN BY: DATE: PROJECT NO.: PRINT DATE DRAWING NAME: REGISTERED ARCHITECT !CHARD 0. F E1} C T STATE OF WASHINGTON JKW 08102107 A07 -504 08/16/07 - 8:48am A07- 504PLN.dwg SHEET A0.0 Copyright 2006 Freiheit & Ho Architects, Inc_, P.S. CEILING PLAN KEY NOTES REFLECTED CEILING PLAN SCALE: I /5" = 1 GN -0I REPLACE ALL EXISTING 2X4 FLUORESCENT FIXTURES W/ NEW BUILDING STANDARD 2X4 FLUORESCENT FIXTURE, 3 ", IS CELL PARABOLIC LOUVER, LIGHTOLIER DPS2GI$LSSS2, OR APPROVED EQUAL, W/ (3) T -S LAMPS. (0 -02) PROVIDE NEW BUILDING STANDARD WHITE EXIT SIGN. (GN -03) CLEAN ALL EXISTING I-IVAG SUPPLY AND RETURN DIFFUSERS AND PAINT WHITE TO RETURN TO LIKE -NBN CONDITION. (GN -04) PAINT EXISTING CEILING GRID TO BRING TO LIKE -NEW CONDITION. PROVIDE AND INSTALL NEW BUILDING STANDARD CEILING TILES (ACT-O. CEILING PLAN LEGEND NEW BUILDING STANDARD 2X4 FLUORESCENT FIXTURE, TO REPLACE EXISTING; 3 ", IS CELL PARABOLIC. LOUVER, LIGHTOLIER DP526I8L5332, OR APPROVED EQUAL, W/ (31 T -8 LAMPS. EXISTING CEILING GRID TO REMAIN, PROVIDE AND INSTALL NEW BUILDING STANDARD CEILING GRID. FINISH SCHEDULE 40'11 4012 4015 4014 4015 4016 REGEPTIOw OPEN OFFICE CONFERENCE OFFICE OFFICE OFFICE OFFICE CARPET C-I CARPET C-I CARPET C CARPET C-I CONFERENCE OFFICE 1 4072 l 1 4073 1 RUBBER BASE B-I RUBBER BASE B -I RUBBER BASE B-I RUBBER BASE B-I RUBBER SASE RUBBER BASE 5-I B-I kN -01) TYP. EX F -I P -I EX P -I EX P -I CARPET CARPET C-I C--I EX P -I P -I KN-o4 TYP. KN-OS) TYP. OFFICE 4074 C-I KN-0I) EX F -I EX P -I EX P -I EX P -I EX EX OPEN OFFICE 4071 1=X P-2 P -I EX P -I EX P -I EX EX P -I P -I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KN-0:1 KN-06) TYP. OFFICE 4075 KN -15 ) P -I EX P -I EX P -I EX P -I 2 OFFICE 1 4076 1 ROOM FLOOR SASE N. WALL E. WALL S. WALL W. WALL CEILING EX/AGT EX/ACT-I EX/ACT EX/ACT-I EX/AGT EX/ACT-I EX/ACT EX/ACT -I EX EX P -I P -I EXACT EX/ACT EX/ACT-I EX/ACT-I FLOOR PLAN LEGEND = = = = EXTENT OF DEMOLITION — — — ■ EXTENT OF NEW ACCENT PAINT EXISTING CONSTRUCTION TO REMAIN FLOOR PLAN KEYNOTES (KN -0I) (KN -02) DEMOLISH EXISTING WALL CONSTRUCTION AS INDICATED, PROTECT ALL ADJACENT CONSTRUCTION TO REMAIN DURING DEMOLITION AND REPAIR DAMAGED AREAS TO LIKE -NEW CONDITION. REMOVE ALL EXISTING FLOORING AND BASE IN ALL AREAS OF SUITE. PROTECT ALL WALLS AND DOORS DURING DEMOLITION AND REPAIR DAMAGED AREAS TO LIKE -NEW CONDITION. PREPARE SUBSTRATE 50 IT 15 SMOOTH, LEVEL, AND READY TO RECEIVE NEW FINISH PER FINISH SCHEDULE ON SHEET A3.0. (KN -03) PAINT WALL ACCENT PAINT COLOR (F -2) AS INDICATED. (KN -04) REPLACE ALL OUTLETS, SWITCHES, OUTLET COVER PLATES AND SWITCH COVER PLATES WITH NEW BUILDING STANDARD WHITE PLATES. REMOVE EXISTING PHONE PALL, RETURN ALL WIRING TO SOURCE. PATCH AND REPAIR EXISTING CONSTRUCTION TO REMAIN TO RETURN TO LIKE -NEW CONDITION. (KN -06) REPLACE EXISTING BLINDS W/ NEW BUILDING STANDARD BLINDS. (KN -07) PATCH AND REPAIR ALL HOLES IN EXISTING WALL CONSTRUCTION AS REQUIRED TO BRING TO LIKE -NEW CONDITION, TYPICAL THROUGHOUT SUITE. CKN -05) REPAIR AND TOUCH -UP ALL DOORS AS REQUIRED TO BRING TO LIKE -NEW CONDITION, TYPICAL THROUGHOUT SUITE (KN -OBI) REPLACE ALL EXISTING KNOB -TYPE DOOR HARDWARE WITH NEW BUILDING STANDARD ADA COMPLIANT LEVER -STYLE DOOR HARDWARE, TYPICAL THROUGHOUT SUITE. (KN -05) REVIEWED FOR CODE COMPLIANCE APPROVEU AUG 2 8 2001 City Of T k BUILD _ " . , , FINISH LEGEND IV'7 313 NO. MATERIAL: FINISH /COLOR: PAINT P NEW GJN.B. (I) COAT PRIMER (2) COATS PREMIUM LATEX PAINT FLOORING G CARPET EXISTING GAB. (2) COATS PREMIUM LATEX PAINT CEILING ACT ACOUSTIC CEILING TILE I. KELLY MOORE, WESTERN ACOUSTIC, 20, SATIN FINISH 2. BENJAMIN MOORE, SHAKER BEIGE, HC-45, SATIN FINISH I. MARKET READY SUITES - SHAW, IN- TRANSIT 50644, OUTBOUND 44502 BASE 5 RUBBER BASE I. BURKE MERGER, 2 -1/2" STRAIGHT RUBBER BASE 150 NOUGAT. I. BUILDING STANDARD CEILING TILE ARMSTRONG DUNE #1774 2X2 TEGULAR EDGE. RECEIVED CITY OF TUKWILA AUG 2 0 20011 CENTER CONSTRUCTION DOCUMENTS FOR LEGACY @ SOUTHCENTER PARKWAY TENANT IMPROVEMENT 16400 Southcenter Parkway Tukwila, WA 98188 REVISIONS SUITE 407 PERMIT 4 BID SET REGISTRATION REGISTERED HITECT RIU,NARD 0. PRI*IHET STATE OF WA:ANG i OJ DRAWN BY: DATE: PROJECT NO.: PRINT DATE: DRAWING NAME: JKW 08/02/07 A07 -504 08/16/07 - 8:48am A07- 504PLN.dwg • FREIHEIT & HO ARCHITECTS, INC., P.S. 10940 NE 33RD RACE SUITE 202 BELLEW E, WA 98004 P:425.827.2100 F:425.828.6899 SHEET A3.0 massimagiamenaniimem Copyright 2006 Freiheit & Ho Architects, Inc., P.S. EXIT GN -02) IL GN -04 1 - • 4 , --.1p.-- -441■- ■..._ ..___ . _, GN-03) TYP_ ■ i .1 I i 1 CEILING PLAN KEY NOTES REFLECTED CEILING PLAN SCALE: I /5" = 1 GN -0I REPLACE ALL EXISTING 2X4 FLUORESCENT FIXTURES W/ NEW BUILDING STANDARD 2X4 FLUORESCENT FIXTURE, 3 ", IS CELL PARABOLIC LOUVER, LIGHTOLIER DPS2GI$LSSS2, OR APPROVED EQUAL, W/ (3) T -S LAMPS. (0 -02) PROVIDE NEW BUILDING STANDARD WHITE EXIT SIGN. (GN -03) CLEAN ALL EXISTING I-IVAG SUPPLY AND RETURN DIFFUSERS AND PAINT WHITE TO RETURN TO LIKE -NBN CONDITION. (GN -04) PAINT EXISTING CEILING GRID TO BRING TO LIKE -NEW CONDITION. PROVIDE AND INSTALL NEW BUILDING STANDARD CEILING TILES (ACT-O. CEILING PLAN LEGEND NEW BUILDING STANDARD 2X4 FLUORESCENT FIXTURE, TO REPLACE EXISTING; 3 ", IS CELL PARABOLIC. LOUVER, LIGHTOLIER DP526I8L5332, OR APPROVED EQUAL, W/ (31 T -8 LAMPS. EXISTING CEILING GRID TO REMAIN, PROVIDE AND INSTALL NEW BUILDING STANDARD CEILING GRID. FINISH SCHEDULE 40'11 4012 4015 4014 4015 4016 REGEPTIOw OPEN OFFICE CONFERENCE OFFICE OFFICE OFFICE OFFICE CARPET C-I CARPET C-I CARPET C CARPET C-I CONFERENCE OFFICE 1 4072 l 1 4073 1 RUBBER BASE B-I RUBBER BASE B -I RUBBER BASE B-I RUBBER BASE B-I RUBBER SASE RUBBER BASE 5-I B-I kN -01) TYP. EX F -I P -I EX P -I EX P -I CARPET CARPET C-I C--I EX P -I P -I KN-o4 TYP. KN-OS) TYP. OFFICE 4074 C-I KN-0I) EX F -I EX P -I EX P -I EX P -I EX EX OPEN OFFICE 4071 1=X P-2 P -I EX P -I EX P -I EX EX P -I P -I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KN-0:1 KN-06) TYP. OFFICE 4075 KN -15 ) P -I EX P -I EX P -I EX P -I 2 OFFICE 1 4076 1 ROOM FLOOR SASE N. WALL E. WALL S. WALL W. WALL CEILING EX/AGT EX/ACT-I EX/ACT EX/ACT-I EX/AGT EX/ACT-I EX/ACT EX/ACT -I EX EX P -I P -I EXACT EX/ACT EX/ACT-I EX/ACT-I FLOOR PLAN LEGEND = = = = EXTENT OF DEMOLITION — — — ■ EXTENT OF NEW ACCENT PAINT EXISTING CONSTRUCTION TO REMAIN FLOOR PLAN KEYNOTES (KN -0I) (KN -02) DEMOLISH EXISTING WALL CONSTRUCTION AS INDICATED, PROTECT ALL ADJACENT CONSTRUCTION TO REMAIN DURING DEMOLITION AND REPAIR DAMAGED AREAS TO LIKE -NEW CONDITION. REMOVE ALL EXISTING FLOORING AND BASE IN ALL AREAS OF SUITE. PROTECT ALL WALLS AND DOORS DURING DEMOLITION AND REPAIR DAMAGED AREAS TO LIKE -NEW CONDITION. PREPARE SUBSTRATE 50 IT 15 SMOOTH, LEVEL, AND READY TO RECEIVE NEW FINISH PER FINISH SCHEDULE ON SHEET A3.0. (KN -03) PAINT WALL ACCENT PAINT COLOR (F -2) AS INDICATED. (KN -04) REPLACE ALL OUTLETS, SWITCHES, OUTLET COVER PLATES AND SWITCH COVER PLATES WITH NEW BUILDING STANDARD WHITE PLATES. REMOVE EXISTING PHONE PALL, RETURN ALL WIRING TO SOURCE. PATCH AND REPAIR EXISTING CONSTRUCTION TO REMAIN TO RETURN TO LIKE -NEW CONDITION. (KN -06) REPLACE EXISTING BLINDS W/ NEW BUILDING STANDARD BLINDS. (KN -07) PATCH AND REPAIR ALL HOLES IN EXISTING WALL CONSTRUCTION AS REQUIRED TO BRING TO LIKE -NEW CONDITION, TYPICAL THROUGHOUT SUITE. CKN -05) REPAIR AND TOUCH -UP ALL DOORS AS REQUIRED TO BRING TO LIKE -NEW CONDITION, TYPICAL THROUGHOUT SUITE (KN -OBI) REPLACE ALL EXISTING KNOB -TYPE DOOR HARDWARE WITH NEW BUILDING STANDARD ADA COMPLIANT LEVER -STYLE DOOR HARDWARE, TYPICAL THROUGHOUT SUITE. (KN -05) REVIEWED FOR CODE COMPLIANCE APPROVEU AUG 2 8 2001 City Of T k BUILD _ " . , , FINISH LEGEND IV'7 313 NO. MATERIAL: FINISH /COLOR: PAINT P NEW GJN.B. (I) COAT PRIMER (2) COATS PREMIUM LATEX PAINT FLOORING G CARPET EXISTING GAB. (2) COATS PREMIUM LATEX PAINT CEILING ACT ACOUSTIC CEILING TILE I. KELLY MOORE, WESTERN ACOUSTIC, 20, SATIN FINISH 2. BENJAMIN MOORE, SHAKER BEIGE, HC-45, SATIN FINISH I. MARKET READY SUITES - SHAW, IN- TRANSIT 50644, OUTBOUND 44502 BASE 5 RUBBER BASE I. BURKE MERGER, 2 -1/2" STRAIGHT RUBBER BASE 150 NOUGAT. I. BUILDING STANDARD CEILING TILE ARMSTRONG DUNE #1774 2X2 TEGULAR EDGE. RECEIVED CITY OF TUKWILA AUG 2 0 20011 CENTER CONSTRUCTION DOCUMENTS FOR LEGACY @ SOUTHCENTER PARKWAY TENANT IMPROVEMENT 16400 Southcenter Parkway Tukwila, WA 98188 REVISIONS SUITE 407 PERMIT 4 BID SET REGISTRATION REGISTERED HITECT RIU,NARD 0. PRI*IHET STATE OF WA:ANG i OJ DRAWN BY: DATE: PROJECT NO.: PRINT DATE: DRAWING NAME: JKW 08/02/07 A07 -504 08/16/07 - 8:48am A07- 504PLN.dwg • FREIHEIT & HO ARCHITECTS, INC., P.S. 10940 NE 33RD RACE SUITE 202 BELLEW E, WA 98004 P:425.827.2100 F:425.828.6899 SHEET A3.0 massimagiamenaniimem Copyright 2006 Freiheit & Ho Architects, Inc., P.S. CONSTRUCTION DOCUMENTS FOR LEGACY @ SOUTHCENTER PARKWAY SUITE 407 TENANT IMPROVEMENT 16400 Southcenter Parkway Tukwila, WA 98188 REVISIONS PERMIT 4 BID SET REGISTRATION 1 CHARD O. FREIHLiT ?� Mir: OFW'. !INGTCh's FREIHEIT & HO ARCHITECTS, INC., P.S. 10940 NE 33RDPLfCE SUITE202 BELLEWE,WA 98004 P :425.827.2100 F:425.828.6899 DRAWN BY: JKW DATE: 08/02/07 PROJECT NO.: A07/504 PRINT DATE: 08/16/07 - 8:48am DRAWING NAME: A07- 504PLN.dwg SHEET A6.0 milegmElommzesmom Copyright 2006 Freiheit & Ho Architects, Inc., P.S. 3 WHERE HANGER WIRES i= ASTENERS INTO ARE MORE THAN 1:6 Z / STRUCTURE OUT -OF- PLUMB, PROVIDE COUNTER SLOPING WIRES TO ` \ STRUCTURE IINDUCED �., T SPLINE ABOVE INSTALL #I2 GA. VERTICAL WIRE AT 4' -0" TO MAIN RUNNER AND ABOVE. 6A. W1RE GROSS BRACING IN OF MAIN RUNNER AT 12'-O° DEGREE SHALL BE ANGLES IN WITH THE FIRST POINT FROM EACH WALL. STRUT (I -5/8° MIN.) ADEQUATE BRAGINGNR DEoUAT RESTRAINT POINTS SHALL BE FT (3658 MM) ER IN ON CENT WITH THE FIRST POINT (1821 MM) FROM EACH WALL. AS REQUIRED UNDER ASTM 6635 S WIRE AND TO A TM BE 0636. GAUGED PER ASTM 0841 TABLE 3. LIGHT FIXTURE SUPPORT PER ASTM 155S0_ O.G. CONNECTED INSTALL #12 BOT STt�ucTURE EACH PLANT: / O.C. AT 45 BOTH DIRECTIONS WITHIN 6' -0" % . � WIRES AT 4' O.G. - NO TRAPEZE I:6 TO AVOID PLUh�i, TYPICAL MAINTAIN SPACING ;i AS REQUIRED >< HANGER EACH DIRECTION MORE THAN OIJT- OF- OBSTRUGTION5 HANGER 'OQO INSTALL A DEGREES HORIZONTAL ► MAX. PLACED 12 BOTH DIRECTIONS WITHIN 6 FT NOTE: I. INSTALL E5, ASTM 2. SUPPORTING S0 AND SPACED 3. PROVIDE ATTACHMENT BRACING WIRE AND CAPACITY TO MAINTAIN PERIMETER MAIN RUNNER CROS/ CEILING • GEN. ACOUSTICAL CEILING THIS DETAIL APPLIES TO SUSPENDED CEILINGS WHICH MUST BE BRACED IN RESPONSE TO SEISMIC LOADS. USE IN UBG SEISMIC ZONES 2, 3, AND 4. SUPPORT A6.0 SCALE: NOT TO SCALE A&O SCALE: NO SCALE STEEL STUD WALL BRACE STUD GAGE) @ 4S" AGOUSTIGAL CONT. STEEL RUNNER ANCHOR TO SLAB POWDER ACTUATED 2 TYPICAL 4, 11111 II 1111 111 1111111 1 11111 WT I 1111111 III II I I 1 „IIIII IIIII, 1 �1�1111111�11111111 Illlllllllllll II I1 1111 111111111,111 1 1 111,1 11111111 1�1�1 �111�1�111 �1 1�111 1 (MATCH O.G., FASTEN STRUCTURE CEILING W/ 0.146" FASTED WALL WALL TO ABOVE TILE = ' . CONT. L-METAL TRIM --<--- WALL CONSTRUCTION PER PLAN CHANNEL. DIA. @ 36" 14.1 O.G. il 1 SCHEDULED BASE ACOUSTICAL SEALANT fl/ SCHEDULED FLOORING _ CONSTRUCTION A6.0 SCALE: 3' = I' -0" C %E CO 1A pR oX10fr : I, 0 2 B 251 CAW Of Ai RECEP/ED CITY OF TI!€4'NILA AUG 2 0 2007 ,,, , _,I, - , 1)01 41. 3 13 CONSTRUCTION DOCUMENTS FOR LEGACY @ SOUTHCENTER PARKWAY SUITE 407 TENANT IMPROVEMENT 16400 Southcenter Parkway Tukwila, WA 98188 REVISIONS PERMIT 4 BID SET REGISTRATION 1 CHARD O. FREIHLiT ?� Mir: OFW'. !INGTCh's FREIHEIT & HO ARCHITECTS, INC., P.S. 10940 NE 33RDPLfCE SUITE202 BELLEWE,WA 98004 P :425.827.2100 F:425.828.6899 DRAWN BY: JKW DATE: 08/02/07 PROJECT NO.: A07/504 PRINT DATE: 08/16/07 - 8:48am DRAWING NAME: A07- 504PLN.dwg SHEET A6.0 milegmElommzesmom Copyright 2006 Freiheit & Ho Architects, Inc., P.S.