Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D07-355 - FITNESS OUTLET - WALLS AND DOOR
FITNESS OUTLET 17250 SOUTHCENTER PY D07.355 City of Tukwila Design Occupant Load: 76 BUILDING OFFICIA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D07 -355 Occupant /Tenant: FITNESS OUTLET Building Address: 17250 SOUTHCENTER PY, SUITE NO. 100 Parcel No.: 2623049117 Property Owner: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA 98006 Use: RETAIL SALES Occupancy Group/Division: M Type of Construction: V -B Automatic Sprinkler System: Provided: Y Required: Y DATE o 0/z /z413 THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: Value of Construction: Type of Fire Protection: Type of Construction: City f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2623049117 17250 SOUTHCENTER PY TUKW FITNESS OUTLET 17250 SOUTHCENTER PY , TUKWILA WA WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA 98006 DEVELOPMENT PERMIT Contact Person: Name: GEORGE TSUKAMAKI Address: 205 -NE NORTHLAKE WAY STE 200 , SEATTLE WA 98105 Phone: 206 -633 -1522 Contractor: Name: DAVIS SCHUELLER INC. Address: 20700 44 AV W , LYNNWOOD WA 98036 Phone: 206 775 -9400 Contractor License No: DAVISSI105PN DESCRIPTION OF WORK: TENANT IMPROVMENT, CONSTRUCT NON - BEARING WALLS AND DOOR TO TENANT SPACE $15,000.00 V -B * *continued on next page ** doc: IBC -10/06 D07 -355 Permit Number: Issue Date: Permit Expires On: Expiration Date: 07/01/2008 Fees Collected: International Building Code Edition: Occupancy per IBC: D07 -355 10/12/2007 04/09/2008 $518.28 2006 0019 Printed: 10 -12 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature Print Name: doc: IBC -10/06 City o Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us LJ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or . e performan •f work. I am authorized to sign and obtain this development permit. Permit Number: DOZ -355 Issue Date: 10/12/2007 Permit Expires On: 04/09/2008 Date: 10`k Date: (.0 CD This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -355 Printed: 10 -12 -2007 Parcel No.: 2623049117 Address: Suite No: Tenant: FITNESS OUTLET Swe 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 13: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17250 SOUTHCENTER PY TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -355 ISSUED 09/13/2007 10/12/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: D07 -355 Printed: 10 -12 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IF'C 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 26: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this doc: Cond -10/06 D07 -355 Printed: 10 -12 -2007 doc: Cond-10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** project. 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 30: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 31: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 33: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. D07 -355 Printed: 10 -12 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us J 75 L I Date: ( 0 12 D07 -355 Printed: 10 -12 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htux/Iwww.citukwila.wa.us Site Address: 1725' 5 C 57 &(_ (tuA - r Tenant Name: r T(JE`J:, OK.4TLeT Property Owners Name: CIING r (F'S L . L.C. . �J Mailing Address: 4S l ' I i .. Se", f .k.Eck.4k.S City tide Building Permit No -- 35:5 - Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. fO U (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 2 42-3c74-41 King Co Co Assessor's Tax No.: L g 0 ac 1 I ? Suite Number: IOC) Floor: 1 New Tenant: jg Yes ❑ .. No State 4r8 CinCra Zip CONTACT PERSON — who do we contact when your permit is ready to be Name: lt6r'it- TSL.tK444 -try -t Day Telephone: O 1522_ Mailing Address: 74:6 i t t.P71-kiet1r -S GOTT t 5Cf1T6 AnO, 5t1 ( eA - City State Zip E -Mail Address: G T4- JONE PA HA-P.( - C-c4'I Fax Number: `Z0C, 'C.33 ' (S� GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name:■ .fES'T 4 t-4A.& t • Mailing Address: Z &X Z 4I Ale (.13017 S ( J176- .(X. T7C -(S. Ltd aS I Zip Day Telephone: '(c G33- Fax Number: 24.9(0 • Contact Person: C 51ZC 5 Lt(' - fr1i' -4 t E -Mail Address: G T - J c7Pes."1`5e4 r -44 (_ c-61 - Company Name: Mailing Address: • Contact Person: E -Mail Address: Q:\Applications\Fonns- Applications On Line\ -2006. Permit Application.doc Revised: 9 -2006 bh City State Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): T T 1. • — 241.—Y.4 c 9(Ac.�/1;%=>or.- r ib 76NAIS Will there be new rack storage? ❑ Yes X . No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1' Floor 2nd Floor 3`° Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Interior Remodel 243 Addition to Existing Structure Type of Construction per IBC Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None (specify) ❑ Other ci Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Wpplications\Forms- Applications On Limel3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 BUILDING 0 R OR AU Signature: D A NT: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date:• (p , 46:124e (St-tleR 1# 4 1 Day Telephone: Mailing Address: 20S 1 1- 3S7141.19t6 f, '7- 1 7t5 Z ., , 59J TtL • City Print Name: � G55- t522-- State Zip Date Application Expires: 3-1 Date Application Accepted: G 't3 -O7 Q:Npplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 bh Staff Initials: Page 6 of 6 i Receipt No.: R07 -02235 Payee: JONES TSUKAMAI {I ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 000/322.100 000/386.904 RECEIPT Parcel No.: 2623049117 Permit Number: D07 -355 Address: 17250 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 09/13/2007 Applicant: FITNESS OUTLET Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Amount: $315.88 Initials: WER Payment Date: 10/12/2007 11:31 AM User ID: 1655 Balance: $0.00 Payment Check 10526 315.88 Account Code Current Pmts 311.38 4.50 Total: $315.88 i 17 TOTAL 31:5 doc: Receiot -06 Printed: 10 -12 -2007 Receipt No.: R07 -01976 Payee: JONES TSUICAMAKI TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049117 Permit Number: D07 -355 Address: 17250 SOUTHCENTER PT TUICW Status: PENDING Suite No: Applied Date: 09/13/2007 Applicant: FITNESS OUTLET Issue Date: Initials: WER Payment Date: 09/13/2007 03:06 PM User ID: 1655 Balance: $315.88 Amount Payment Check 10508 202.40 Account Code Current Pmts 000/345.830 202.40 Total: $202.40 Payment Amount: $202.40 2763 09/13 ?710 TOTAL. 202 doc: Receiot -06 Printed: 09 -13 -2007 Project 1 Type Inspec ,! v A/7 : 5 - 0 SoIiaro t 4 P, Date Called: Special Instructions: 204, Date Wanted: a. m. Requester: Phone No: 70-`?6 0 INSPEQTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 3 70 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Civol//io7/6_, — /'1//4 0/ 7 / //t/// / INSPECTION RECORD Retain a copy with permit Date: y_ REINSPECTION 7 REINSPECTION FEE REQUItRED. Prior to inspection. fee must be at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Date: Pro„ jectf I-- ► - -1 \ie C 6,41,4 Type of Inspection: Fri 4 - 1 !` Address: 17 2 Sc) ScntfhcgAM/ Date Called: k, Special Instructions: Date Wanted:, (0—) Requester: 7161to....5, !O W y INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. COMMENTS: c . -e 4 ti jr\j<, p-061 19- )k,_/ A 'Date: 1714, Corrections required prior to approval. 1 .$ 00 REINSPECTION EE REQUIRE Prior to inspection, fee must be p id at 6300 Southcenter Blvd.. Suite 00. Call the schedule reinspection. 'Receipt No.: COOM v /j Address: / -� �,Date l 7 2 S� �l�l �fi/i/ / '` Called: Ac/ 'T /07 7," Date Wan t �7 J /� G—/ !/ ,�, ( Requester: P is 3 — S/ p — / r, 1 rI 6 lG TU lJ ( ?/7 .5<;-: / J /// ?_5' - Proje / 7" Zl` (,27/4c-1 Type of Inspection: /2, 9 Address: / -� �,Date l 7 2 S� �l�l �fi/i/ / '` Called: Special Instructions: f it) // Date Wan t �7 J /� G—/ !/ ,�, ( Requester: P is 3 — S/ p — c 6 y INSPECT N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. El Corrections required prior to approval. nspector: REINSPECTION FEE REQ ED. for to inspection, fee must be p at 6300 Southcenter Blvd.. S. e 100. Call the schedule reinspection. R elpt No.: "we- INSPECTION RECORD Retain a copy with permit 2 'Date: / 'Date: Project: 55 Pt-irte,r Type of Inspection: Hood & Duct: Address: 172 C Suite #: I 00 satith «.fi*-<. -- Pr Contact Person: ,56. Occupancy Type: Special Instructions: Phone No.: 06 — y" -- 3v'3 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER I ✓ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 Day - 355 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. COMMENTS: Ern relC44 /. h�, � rqs r<<4" DK J 57ac Inspector: ,.,Sc. 5/ Date: 1,1l/ y / P 2 rs .. i $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the�City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: A71i7-7 5 S 0 Type of Inspection: �� {� L, :1-z_ Address: / 7Z O Suite #: / ( 7 ( 7 . 5C 'Jl !tip Contact Person: GRp bb; Special Instructions: Occupancy Type: Phone No.: o?oG, %vG • 3 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 COMMENTS: Inspector: CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 cvvod c .) t , 411e F ,0o7- 3015 PERMIT NUMBERS Corrections required prior to approval. Date: Hrs.: �) $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 l COMMENTS: G erce 4- Type of Inspection:. 11v.46 5iru# Uw 4- /r' -: 4444;r4:40.1 Address: l �Z S , Suite #: P. Pie .Y:: Contact Person: Special Instructions: Pre -Fire: Phone No.: 1-114 4 c. ` «i 0� Yom. v/C ,! < ei 1 ;le kr1+ 1i•,, Q 1 Ci .F C i ., t. 1j,' r • f � - l WI !!VC r i.4• /) 4 Jr, • i- `1. .167 rn t (.7 (> cr Z n1,949,- ■ / , S !' ■) 7• / /4/7Z- W S 3- ;. I ? -1.,/ t 7'Cr- ✓Ia '' f . J(.? Project: = F;; dc's 9 G erce 4- Type of Inspection:. 11v.46 5iru# Uw 4- /r' -: 4444;r4:40.1 Address: l �Z S , Suite #: P. Pie .Y:: Contact Person: Special Instructions: Pre -Fire: Phone No.: Needs Shift Inspection: ' Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ,! INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. Inspector: 4) INSPECTION RECORD Retain a copy with permit Date: Corrections required prior to approval. Jrr .7 07- ,x • gym " PERMIT NUMBERS Hrs.: A $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule . a reinspection. Word /Inspection Record Form.Doc 1/13/06 _ T.F.D. Form F.P. 113 Project:, I"/ //U (� /f 1�1 Type of In pection: 0 LIZ / A/6 Address: _ ! �2 �U �C�(7 �7�F�ti d,� l ailed: .. ----7:,' Special Instructions: Da a Wanted: //e/2- /n .m. Requestr: Phone No: INSPECTION NO. COMMENTS: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. 0 Corrections required prior to approval. nspector / I f I. 0 10 REINSPECTION REQUIRtD. Prior to inspection, fee must be d at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. eipt No.: 'Date: a'�i. •...H'ZS.j� COMMENTS: lr /Lf' Type of In pg.ction: F /Z 4/-11 / /t/-6 Ad ress: 725) . / / / /- /3 A Vf /Nb - 4) / /y;/W Special Instructions: Date W m / z �p a. Re r i p/c 1 / /r42/ ( e /sue // / .1 ' Pro /v S 5 lr /Lf' Type of In pg.ction: F /Z 4/-11 / /t/-6 Ad ress: 725) . / / q Called: Special Instructions: Date W m / z �p a. Re INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. Corrections required prior to approval. REINSPECTION FEE REQUIRED/Prior to inspection, fee must be p. d at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Re eipt No.: • j___________■INSPECTION RECORD Retain a copy with permit 'Date: PERMIT NO. COMMENTS: Sprinklers: V Type of Inspection: P !ibQv 1 Oziv - Address: 0,9 0 t;. c .• Pic Suite #: Ito .� Contact Person: A-44 x lt.Ar Special Instructions: )3 es II JAS / /a) M4_ 5 o k/.+, -1c:7 I_ o u t o (,. ,A - A 1 - i 0 Re Project: 1 /----, ' NeSs oo--1 itA 1 Sprinklers: V Type of Inspection: P !ibQv 1 Oziv - Address: 0,9 0 t;. c .• Pic Suite #: Ito .� Contact Person: A-44 x lt.Ar Special Instructions: Pre -Fire: AI Phone No.: 0 5 - 3(c9 o78/ Needs Shift Inspection: Sprinklers: V Fire Alarm: ; Hood & Duct: N Monitor: Pre -Fire: AI Permits: 4), Occupancy Type: 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Inspector: On S J L Date: /t2 Hrs.: t rs.. 141)k I $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 a7- —alp PERMIT NUMBERS n Corrections required prior to approval. T.F.D. Form F.P. 113 September 27, 2007 George Tsukamaki 205 NE Northlake Way Suite 200 Seattle WA 98105 City of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number D07 -355 Fitness Outlet —17250 Southcenter Pkwy Suite 100 Dear Mr. Tsukamaki, If you have any questions, please contact me at (206) 431 -3760. Sincerely, C- ROAJ1 7- Bill Rambo Permit Technician encl File No. D07 -355 P:\Permit Cente,\Correction Letters \ 2007007 -355 Correction Ur #1.DOC wer Steven M. Mullet, Mayor This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have included comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have.enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: September 27, 2007 Project Name: Fitness Outlet Permit #: 007 -355 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Plan notes Indicate Mercantile with occupancy of 25. Mercantile calculations shall be 30 gross per IBC table 1004.1. The 2436 sq ft shown minus 160 sq foot of the storage room and restroom shall calculate to 2276 sq ft / 30 = 76 occupants. Revise notes to meet occupant loads. 2. The occupant load exceeding 50 occupants shall require two exits. However the two exits shown do not meet code for placement of emergency exits. Where a building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2, the separation distance of the exit doors or exit access doorways shall not be less than one -third of the length of the maximum overall diagonal dimension of the area served. An additional exit shall be required. The plans show and exit In the back to a corridor. However and exit shall not pass thru a storage room. In this case the storage room could be adjusted to allow a small hallway to the exit. Please revise plan to show an additional exit. (IBC 1015.2.1 & 1014.2 #2) 3. Egress and emergency lighting shall be shown on the reflective ceiling plan. Revise plan to show illuminated egress paths and exit signs. (IBC 1006) Should there be questions concerning the above requirements, contact the Building Division at 206-431 -3670. No further comments at this time. ACTIVITY NUMBER: D07 -355 DATE: 10 -02 -07 PROJECT NAME: FITNESS OUTLET SITE ADDRESS: 17250 SOUTHCENTER PY Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 04 g i ivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-04-07 Complete I ✓ Comments: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator ❑ Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: n C DUE DATE: 11 -01-07 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D07 -355 DATE: 09 -13 -07 PROJECT NAME: FITNESS OUTLET SITE ADDRESS: 17250 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS• BCtlffing DiVISIOn V v � Public Works ' DE Complete PLAN REVIEW %ROUT SLIP ERMINATION OF COMPLETENESS: (Tues., Thurs.) Please Route Documents/routing slip.doc 2 -28 -02 TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: � 1 Fire Prevention Structural ❑ Permit Coordinator Incomplete Structural Review Required m t� p� y, pi-D1 Pla ng Division DUE DATE: 09 -18 -07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 10 -16 -07 n Approved ❑ Approved with Conditions L, Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: ` n I en _0 7 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: C 3 . Ori Plan Check/Permit Number: D07 -355 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OF TUKWILA OCT -3 2007 PERMIT CENTER Project Name: Fitness Outlet Project Address: 17250 Southcenter Pkwy Contact Person: George Tsukamaki Phone Number: 206, • 6:33 • (5 2..2— Summary of Revision: - hC S0645 - 1 `T A• 4. -- Ke SKI - 2-- Sheet Number(s): A ?k - 2- , "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: J Entered in Permits Plus on 10 d J I (4 \app ications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: License Information License DAVISSI105PN Licensee Name DAVIS SCHUELLER INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601273797 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 20700 44TH AVE W STE 280 Address 2 City LYNNWOOD County SNOHOMISH State WA Zip 98036 Phone 4257759400 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/15/1990 Expiration Date 7/1/2008 Suspend Date Separation Date Parent Company Previous License SEACRMI104DE Next License SILVECI988QO Associated License Business Owner Information Name Role Effective Date Expiration Date DAVIS, BILL E PRESIDENT 01/15/1990 SCHUELLER, DANETTE SECRETARY 01/15/1990 DAVIS, BARBARA D TREASURER 01/15/1990 SCHUELLER, KENNETH E VICE PRESIDENT 01/15/1990 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Account Effective I Expiration Cancel Impaired Bond Received https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= DAVISSI105PN 10/12/2007 Door Schedule Door No. Type Thk. Opening Size Door MU, Fin. Frame Mtl. Fin. Remarks 1 A 1 3/4" 3' —O x B/S WOOD B/S WOOD B/S Symbols Detail Indicator Elevation Indicator Section Indicator HALL -d Room Name 3000 Room Number Revision Indicator General Notes Grid Line Exist'g Partitions bh B/S Partitions O 2 or Mu. STUD O 3 5/e" y11_ STUD B/S Sound Partitions ✓ 2 I/2" M 1. STUD <> 3 5/8" MTh STUD B/S Demising Fir to Slab Partition 0 2 1/2" Mn STUD 0 35/a 1111 STUD B/S Full Height Relite B/S Partial Height Relite 6" TYP. Door Number Door Type Hardware Set 1. GENERAL A. The Contractor shall be governed by all conditions as indicated in the Construction Drawings, Specifications for the building, and the Specifications for the Tenant Improvements. B. B/S indicates "Building Standard" as provided by the Owner and /or specified in the Construction Documents. C. The Contractor shall be responsible for safety in the area of work in accordance with all applicable safety codes. D. The Contractor shall indemnify and hold harmless the Owner /Space Planner for injury or death to persons or damage to property caused by the negligence of the Contractor, his agents, employees or subcontractors. E. Each Contractor is responsible for any damage to adjacent work and is responsible for the repair of said damage at his expense. CODES A. All work shall conform to the applicable building codes and ordinances. In case of any conflict where the methods or standards of installation or the materials specified do not equal or exceed the requirements of the laws or ordinances, the laws or ordinances shall govern. Notify the Space Planner of all Conflicts. THE DRAWINGS AND SPECIFICATIONS A. Structural, plumbing, mechanical, electrical and fire protection drawings are supplementary to these drawings. The Contractor shall coordinate the work of each consulting engineer with these drawings and the Tenant Improvement Specifications and shall notify the Space Planner of all discrepancies with a written request for clarification. Any work installed in conflict with these drawings or the Tenant Improvement Specifications shall be corrected by the Contractor at no expense to the Owner, Tenant or the Space Planner. 4. DIMENSIONS A. All information shown on the drawings relative to existing conditions is given as the best present knowledge but without guarantee of accurac The Contractor shall field verify existing conditions and dimensions and shall notify the Space Planner of any discrepancies or conditions adversely affecting the design prior to proceeding with the item of work affected. B. Dimensions on the plans are typically to the finish face of partitions or to the center line of columns. C. Door and cased openings without location dimensions are to be six (6) inches from the faces of the adjacent partition or centered between partitions. D. Locate partitions that are not dimension, flush and square with the existing structure or on the centerline of a window mullion as shown. 5. DO NOT SCALE DRAWINGS A. The Contractor shall use dimensions shown on the drawings and actual field measurements. Notify the Space Planner of any discrepancies found 6. ABBREVIATIONS A. Throughout the drawings are abbreviations which are in common use. The list of abbreviations provided is not intended to be complete or representative of conditions or materials actually used on the project. The Space Planner will define the intent of any in question, 7. COORDINATION A. The General Contractor shall be responsible for the coordination and verification of the work of all trades to assure compliance with the drawings and specifications. 8. FIRE PROTECTION A. Building is fully sprinklered throughout. Fire Protection Contractor shall provide Fire Protection drawings as required by the governing authority. B. Provide fire protection at all penetrations of fire rated elements required by the fire official. Y• 3 0 2 $a $3, 2'x4' Fluorescent Fixture 2'x2' Fluorescent Fixture 1'x4' Fluorescent Fixture 2' or 4' Fluorescent Fixture F Fluorescent Wallwasher IC1 Recess Down Light Suspended Light Fixture Exit Sign Indicates Circuit Switch Two Level Switch 3 —Level Switch t 'I► 0 Wall Mid Outlets Duplex Wall Mtd Outlets Quad Wall Outlet Dedicated Circuit Wall Mtd Tel Outlet Wall Mtd Data Outlet Elec Floor Outlet Tel Floor Outlet Data Floor Outlet GENERAL CONSTRUCTION A. The contractor shall investigate and verify locations of structural, mechanical and electrical elements and other existing conditions prior to drilling or cutting of slabs or structural members. Notify the Space Planner of any conflicts prior to beginning work. B. The Contractor shall be responsible for providing all wall blocking as required for all wall and ceiling mounted items. C. All construction shall be stabilized against lateral movement in accordance with the requirements of the latest adopted edition of the IBC in the local jurisdiction. D. Ceiling heights, where indicated, are from sub floor to bottom of ceiling grid or other finished surface. E. Mechanical, electrical, vertical transporting and sprinkler work shall be conducted under separate permit. F. All wood used in interior wall framing shall be fire — retardant treated wood. 10. GENERAL FINISH NOTES A. There shall be no exposed pipe, conduit, duct, vents, etc. All such lines shall be concealed or furred and finished, unless noted as exposed construction on drawings. B. Offset studs where required so that finish wall surfaces will be flush. C. Provide galvanic insulation between .dissimilar metals. 11. WALL FINISH NOTES A. All paint, wallcoverings and wall panels shall be applied in accordance with the manufacturer's specifications for the particular surface applied upon. B. Samples of all finish colors specified shall be submitted for approval to JONES TSUKAMAKI INC. prior to the commencement of work. C. Flame spread ratings for interior finish to be Class III or better, all textile wall covering shall have a Class I flame spread classification. D. Paint 1 is the general paint color unless otherwise noted. 12. FLOOR FINISH NOTES A. The Carpet Contractor shall furnish and install rubber reducer strips at locations where carpet and resilient flooring meet. Provide color samples for approval. B. Floor covering in closets shall be the same as that of the space onto which the closet opens, unless otherwise noted. C. Prepare floor per Flooring and Carpet Manufacturer's recommendations and Shell and Core Specifications to provide level area for flooring installation and level flooring transitions. 13. ELECTRICAL /TELEPHONE NOTES A. The Electrical Contractor shall be responsible to maintain compliance with all codes and obtain all necessary permits, B. All deviations from dimensioned locations must be approved by the Space Planner. C. The Electrical Contractor shall verify the location of each core drill with the existing structure, piping, conduit, etc. and shall notifying the Space Planner of any conflicts or obstructions. All core drill locations will be provided by the Space Planner. D. Any discrepancies between existing conditions and Contract Documents should be called to the attention of the Spaces Planner E. Electrical /telephone outlets will be mounted vertically at 15 "a,f.f. unless noted. All wall mounted receptacles located in casework are to be mounted horizontally unless otherwise noted. F. Special heights are noted . adjacent to the outlet. G. The Electrical Contractor shall be responsible to maintain compliance with all ADA requirements for heights of fixtures and devices (i.e. switches, outlets, etc.). 14. MECHANICAL NOTES A. The HVAC system shall comply with all applicable codes. B. The Contractor shall verify sizes and locations of all openings for mechanical equipment with Mechanical Drawings as well as shop drawings before proceeding with the work. 15. EQUIPMENT A. Where shown on drawings, install Building Standard plumbing fixtures, fire extinguishers and cabinets in accordance with the manufacturer's instructions. FXTF \T OF . WORK 2,436 S.F. Hardware Schedule Item Fin. Description Hdwr. No. a Location Plan B/S SINGLE /LATCH NOTE: 1. DOOR HARDWARE TO BE "LEVER TYPE" PER WAG 51 -40 SEC 1106.3 2. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT J� V FIRST FLOOR PLAN - BUILDING S Not to Scole Remarks ,T i RV1S1OMS No changes shalt be made to the scope of work without prior Q, p approval Tukwila Building NOTE: Revisions will require a new plan subm and may include aatlitiorTal plan review fees FILE COPY ;* No. 04 Phi WAD approval Is subject to errors and omiission% Approval of constvcbc:T c'_ _ ;c'a duce r..ot atitjiorizi) the violation of en r -� 'tt reece~ilt of droved Fe'ci c - c nor viedged: \ Sy Date: a 2 � City of Tukwila SING DIN Index A -1: COVER SHEET A-2: FLOOR PLAN / REFLECTED CEILING PLAN A -3: DETAILS, INTERIOR ELEVATIONS /FINISH PLAN /FINISH SCHEDULE Agency Notes ZONING: OCCUPANCY: OCCUPANT LOAD: NUMBER OF STORIES: CONTRUCTION TYPE: CODE: REFERENCE PERMIT: TENANT S.F.: SUITE 100 BUILDING S,F.: BUILDING '5' Legal Description Vicinity Map TUKWILA URBAN CENTER (TUG) RCANTILE) ACCESSORS PARCEL #'S: 2623049080 2623049081 2623049117 V— B, FULLY SPRINKLED IBC 2006 & ICC /ANSI Al 17.1 -2003 TENANT SHELL PERMIT #D07 -270 2,436 S.F. 46,747 S.F. DESCRIPTION OF WORK: CONSTRUCT NEW TENANT IMPROVEMENTS FOR RLIAIL STORE DESCRIPTION: PARCEL A: THAT PORTION OF THE NORTHWEST QUARTER OF THE EAST QUARTER & OF THE NORTHEAST QUARTER THE SOUTHWEST QUARTER OF SECTION 28, TOWNSHIP 23 NORTH, RANGE 4 EAST, WM, DESCRIBED AS FOLLOWS, BEGINNING AT THE NORTHEAST CORNER OF THE SOUTHEAST QUARTER OF SAID SECTION 26, THENCE NORTH 88 °05'42" WEST ALONG THE NORTH LINE OF SAID SOUTHEAST QUARTER A DISTANCE OF 1998.68' TO THE WEST .LINE OF THE EAST 659.54' OF SAID NORTHWEST QUARTER OF THE SOUTHEAST QUARTER THENCE SOUTH 01 °47'29" WEST ALONG SAID WEST LINE A DISTANCE OF 658.25' TO THE TRUE POINT OF BEGINNING. THENCE CONTINUING ALONG SAID WEST LINE A DISTANCE OF 662.05' TO THE SOUTH LINE OF SAID NORTHWEST QUARTER OF THE SOUTHEAST QUARTER. THENCE NORTH 87'55'02" WEST ALONG SAID SOUTH LINE, 665.56' TO THE WEST LINE OF THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER. THENCE NORTH 01 °12'25" EAST ALONG SAID WEST LINE 661.08 '. THENCE SOUTH 88 °00'38" EAST 678.80' TO THE POINT OF BEGINNING. EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWLA BY DEED RECORDED UNDER RECORDING # 4408290323 FOR MINKLER BOULEVARD. SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. PARCEL B: THAT PORTION OF THE NORTHEAST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 26, TOWNSHIP 28 NORTH, RANGE 4 EAST, WM, DESCRIBED AS FOLLOWS. BEGINNING AT THE NORTHEAST CORNER OF THE SOUTHEAST QUARTER OF SAID SECTION 26, THENCE NORTH 88'05'42" WEST ALONG THE NORTH LINE OF SAID SOUTHWEST QUARTER. THENCE SOUTH 01 °12'25" WEST ALONG SAID EAST LINE 857.29' TO THE TRUE POINT OF BEGINNING. THENCE CONTINUING SOUTH 01'12'25" WEST 661.08' TO THE SOUTH LINE OF SAID NORTHEAST QUARTER OF THE SOUTHWEST QUARTER. THENCE NORTH 87 °55'58 WEST ALONG SAID SOUTH LINE 185.28' THENCE NORTH 01'56'27" EAST 849.95' THENCE NORTH 87 °55'58" WEST 48' THENCE SOUTH 02 °04'07" WEST 10' THENCE NORTH 8755'58 WEST 371.45' TO A TANGENT CURVE TO THE LEFT, WITH A RADIUS OF 25' THENCE SOUTHWESTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 90'55 AN ARC DISTANCE OF 39.87' THENCE NORTH 01'08'95" EAST TO A POINT NORTH 88 °00'86" WEST FROM THE TRUE POINT OF BEGINNING. THENCE SOUTH 86 °00'36" EAST TO THE TRUE POINT OF BEGINNING. EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING # 9408290825 FOR MINKLER BOULEVARD. SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. PARCEL C, THAT PORTION OF THE NORTHEAST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH RANGE 4 EAST, WM, DESCRIBED AS FOLLOWS. BEGINNING AT THE NORTHEAST CORNER OF THE SOUTHEAST QUARTER OF SECTION 26, THENCE NORTH 88'05'42" WEST ALONG NORTH LINE OF SAID SOUTHEAST QUARTER A DISTANCE OF 2678.68' TO THE EAST LINE OF SAID NORTHEAST QUARTER OF THE SOUTHWEST QUARTER. THENCE SOUTH 01°12'25" WEST ALONG SAID EASY LINE 138.32' TO THE SOUTH LINE OF SAID NORTHEAST QUARTER OF THE SOUTHWEST QUARTER THENCE NORTH 87 °58'53" WEST ALONG SAID EAST LINE 185.28' TO THE TRUE POINT OF BEGINNING. THENCE CONTINUING NORTH 87 °55'53" WEST 439.92 ' TO THE EAST RIGHT OF WAY LINE OF SOUTHCENTER PARKWAY. THENCE NORTH 01'08'35" EAST 34.59 ' ALONG SAID EASY RIGHT OF WAY LINE TO A TANGENT CURVE TO THE RIGHT WITH A RADIUS OF 25'. THENCE NORTHEASTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 90+55'31", AND ARC DISTANCE OF 39.87'. THENCE SOUTH 87'53'33" EAST 371.43' THENCE NORTH 02'04'07" EAST 10' THENCE SOUTH 87 °55'53" EAST 48' THENCE SOUTH 01'56'27" WEST 549.95' TO THE TRUE POINT OF BEGINNING. MEM Jones Tsukamaki Inc. 205 NE Northiake Way, Suite 200 Seattle, WA 98105 206/633-1522 2061633 -1552 fax 1111=111111.111=111 These drawings are the property of .:tines Tsukamaki Inc. and are nai to be used or reproduced in any 'manner, except with proir written permission or Jones Tsukanmki Inc. Fitness Outlet Suite 100 Southcenter Sqaure 17250 Southcenter Parkway Tukwila, Wa. REVISIONS: 1 10 -1--07 GENERAL SCALE: As Noted FILE NO: DRAWN: DESIGNED: CHECKED: Sheet Title coVER SI-tEET cITY of Tu I Sheet Number Date 8 -16 -2007 A -1 1841) • LTR# !AM L _• ES A. ST A7 oCi 0 3 2007 PERMIT CENTER SALES FULL HEIGHT PARTITION ON BY TENANT oO � N SCALE: 1/8"=1'– 0" FLOOR PLAN GENERAL NOTES: 1. ELECTRICAL 200 AMP 3 –PHASE 120/208 VOLT SERVICE STUBBED TO AN ELECTRIC PANEL. ELECTRICAL DUPLEX OUTLETS TO BE EVERY 6FT. AROUND THE CIRCUMFERENCE OF THE STORE. PROVIDE FLOOR OUTLETS @ THE WINDOW AREA'S. SEPARATELY METER ELECTRICAL SERVICE 2. CEILING. GRID & LIGHTING INSTALLED PER CODE. STANDARD T–BAR CEILING @ 112' –O" ABOVE THE FLOOR ONE 2`x4' FLUORESCENT LIGHT FIXTURE PER 100 SO. FT. OF PREMISES 3. AT LAV 102 PROVIDE ALL LANDLORD PROVIDED FIXTURES, EQUIPMENT AS NOTED ON SHEET A -3.1, DETAIL 3, SEE ARCHITECTURAL DESIGN GROUP INC. PERMIT DRAWING SET. (UNDER PERMIT #D07 -270) 7' -0" I � I LJ HALL NORTH s STORAGE 101 1. PROVIDE 3/4" PLYWOOD @ NORTH WALL VERTICAL @ 4' -0" 8'-0" A.F.F 2. ALARM, PHONE SYSTEM © NORTH WALL. REFLECTED CEILING PLAN SCALE: 1/8"=1' --O LEGEND X EXIT SIGN – ILLUMINATED PER IBC 1011 EMERGENCY EXIT LIGHT PER IBC 1006 110 DUPLEX OUTLET +44 N— HEIGHT FROM FINISHED FLOOR 2x4 FLUORESCENT LIGHT FIXTURE HVAC -- SUPPLY HVAC – RETURN PHONE OUTLET COMPUTER /DATA OUTLET WALL MOUNTED LIGHT FIXTURE FLOOR MOUNTED OUTLET - LIGHT TRACK SYSTEM – 8' 0 0 0 GENERAL NOTES: Do n..-- 1 i ! • 1. PROVIDE MIN. CLEARANCE IN FRONT OF EXISTING ELECTRICAL PANEL PER NEC. 2. FIXTURES WITHIN 15' -0" OF STOREFRONT SHALL BE SWITCHED SEPARATELY. 3. AREA CONTROLS – THE MAX. LIGHTING TO BE CONTROLLED FROM A SINGLE SWITCH CAN NOT EXCEED A 20 AMP CIRCUIT LOADED TO 80% 4. PROVIDE VENTILATION PER IMC. rIty ' ; , 3;e '3 S� S° f ,_„�� `..?•..,.: "qtr LIGHTING ENERGY CALCULATION: GWB c 9' —O" A.F.F. NORTH NO CHANGES TO LIGHT FIXTURE QTY, RELOCATION ONLY PER TENANT REQUIREMENTS :35 0 1 Mal WWI LEM Jones Tsukamaki Inc, 205 NE Northlake Way, Suite 200 Seattle, WA 98105 2061633 -1522 2061633 -1552 fax These drawings or the property of ones Tsukamaki Inc. and are no to be used or reproduced in amt .•Wanner, except with proir wriiien permission o'• Jones Tsukorraki Inc. Fitness Outlet Suite 100 Southcenter Sqaure 17250 Southcenter Parkway Tukwila, Wa. REVISIONS: 1 10 -10 -07 GENERAL SCALE: As Noted FILE NO: DRAWN: DESIGNED: CHECKED: 1840 >;s STATE OF WASH N GTON RIMIMMIIIMMEM Sheet Title FLOOR PLAN cln OFTUKLA CEILING PLAN ocr o 3 2001 HIVII1 CENTER Sheet Number Date 8-15-2007 A -2 2 1/8 I [' STEEL. TUBE PROVIDE METAL STUDS EACH SIDE OF BRACE. ATTACH W/ 3/8" MIN. / � 7 - N N7 N / x 2 1/2" BOLTS @ 2' -0" O.C. VERTICAL N t/ / FILE FILE FILE FILE PROVIDE ANCHOR BOLTS RI (4) 3/8 DRILLED HOLES WELD T,S. TO PLATE 1/8" STEEL PLATE AS SHOWN ISOMETRIC STIFFENER TO BE PROVIDED @ 6'-0" O.C. ALONG LOW WALL 3 Partial Height Partition Stiffener Scale: 3"=1'-0" DETWALLO7E -1 P 35 .... _..4,4_,,..........„ / a " HEIGHT 1" ELEVATION 3 3/4" EASE EDGES (PCP.) f VARIES � ��� \\ 1x WOOD CAP FINISHED AS REQUIRED 2x3 WOOD PAINTED METAL CORNER ,BEAD/ JOINT COMPOUND 2 1 /2" CONT. METAL TRACK b GWB r 5/8" .. P i>,--,- !__ — SECTION Ln :y ) 9 ;!r' iL� PI ITi D ' :. , . - 1 2 Partial Height Partition Detail Half Scale DETWALLO7A V . \ ii \ 1 1 M IN. MinirdrAll ■IuIIIuuI1IIuIuL uuI■l miliiii iiiiin I■■II■■■■■®■■■IuluIm■r mum CEILING PER ................. `— Kraig PA ' l ,O ,O L ARCH'L I ATTACH CROSS BRACING TO PARTITION W/ (2) #6 SHEET i METAL SCREWS "x I Pi= 2 1 /2 25 GA. G.I. TOP TRACK ,® . 3 -5/8" x 25GA G.I. STUDS 24" O.C. CROSS BRACING MEMBERS - _ 2 STU DS 1 /2 "x ATTA 1 2 " W/ x25 GA. #6 STEEL (3) SHEET METAL SCREWS ATTACH CROSS BRACING TO 5/8" TYPE "X" GWB Iligi FLOOR DECK W/ RAMSET FASTENERS(TYP) . SOUND INSULATION (WHERE REQUIRED) 3 -5/8" CONT. METAL TRACK I � • "le � SEE FINISH SCHEDULE FOR FLOOR/ BASE FINISH SCREWS @ 24" O.C. MIN TYP. Typical Partition Detail NOTE: AT UNSUPPORTED WALLS OVER 7'-9' IN LENGTH PROVIDE DIAGONAL BRACING TO FL DECK Scale: 3" =1' –O" ABOVE AS SHOWN DETWALLO1 C ADJUSTABLE P. LAM TOP SHELVES & SELF EDGE I r / � 7 - N N7 N / N t/ / FILE FILE FILE FILE EQ. 1' -3" 2'-6" 9 -0 EQ. Sales West Scale : 3/8" = 1 — 7 PARTIAL HT. GWB PARTITION WOOD CAP TRANSACTION COUNTER P.LAM ALL EXPOSED SURFACES 6'-9 1/4" 7'_3 1/4" 2 Sales West Scale : 3/8" = 1'-0" CPT-1 CT--1 VCT -1 CB -1 RB -1 FINISH PLAN SCALE: 1/8"=1'-0 LEGEND OF MATERIALS CARPET TILE: DESIGNWEAVE, SHEER DECADENCE COLLECTION PATTERN: Z6452 CASHMERE, COLOR: 00327 TURKISH ANGORA INSTALL 1/4 TURN PORCELAIN TILE: BUILDING STD. 12 "x12 ", COLOR: T.B.D. VINYL COMPOSITON TILE: MANNINGTON, PATTERN: DESIGNER ESSENTIALS COLOR: 259 OLIVIA PORCELAIN COVED BASE: BUILDING STD. 6" COVED, COLOR: T.B.D. RUBBER BASE: ROPPE, PATTERN: 4 ", COLOR: P131 BISQUE GENERAL NOTES: 7 7 TRANSACTION COUNTER ANGLED\ KNEE BRACE OPEN ADJUSTABLE SH ELVES 4'-5 1 /4 " S , -5 1 /4" 10' 11 1/4" 2' - Sales East Scale : 3/8" = CPT -1, RB -1, P -1 ARE THE GENERAL BASE FINISH UNLESS OTHERWISE NOTED BY ROOM / AREA. SEE PLAN - WOOD CAP WALL BEYOND W/ GWB FLOOR: CT -1 BASE: CB -1 WAINSCOT: P--LAM 1 WALL /CEILING: P -1 NORTH TRANSACTION COUNTER P -2 ACCENT WALL PAINT: BENJAMIN MOORE, COLOR: 2148 -40 LIGHT KHAKI FINISH: EGGSHELL LATEX ENAMEL P– LAM 1 PLASTIC LAMINATE: PIONITE, COLOR: AV751 –S CELERY FIBER FINISH: SUEDE 6 3/4' P -1 BASIC WALL PAINT: BENJAMIN MOORE, COLOR: HC -27 MONTEREY WHITE FINISH: EGGSHELL LATEX ENAMEL P-3 ACCENT WALL PAINT: BENJAMIN MOORE, COLOR: 2148-30 MILITARY TAN FINISH: EGGSHELL LATEX ENAMEL 10" 7- WOOD CAP WALL BEYOND W/ GWB - P.LAM Sales South Scale : 3/8" — V--O" MEM MEIN MEE Jones Tsukamaki Inc. 205 NE. Northiake Way, Suite 200 Seattle, WA 98105 206/633-1522 2061633 -1552 fax These drawings ore the property of dbnes Tsukamaki Inc. and cre noI to be used or rearoduced in any :manner, except with proir written permission n= Jones Tsukarrc i Irt. Fitness Outlet Suite 100 Southcenter Sqaure 17250 Southcenter Parkway Tukwila, Wa. REVISIONS: 1 10 -1 -07 GENERAL SCALE: FILE NO: DRAWN: DESIGNED: CHECKED: A -3 As Noted RECEIVED CITY OF TUKWI OCI 0 3 20o7 PERMIT CENTER Sheet Title DETAILS INTERIOR ELEVATIONS FINISH PLAN Sheet Number Dote 8-16-2007 -. , , ,,i, 1 1/2" i •? FULL HEIGHT