HomeMy WebLinkAboutPermit D07-364 - MAACO - SPRAY BOOTHMAACO SPRAY BOOTH 355 TRECK DR D07 -364 Parcel No.: 0223400042 Address: 355 TRECK DR TUKW Suite No: Tenant: Name: MAACO SPRAY BOOTH Address: 355 TRECK DR , TUKWILA WA Owner: Name: JENKINS PROPERTIES INC Address: PO BOX 53290 , BELLEVUE WA 98015 Phone: Contact Person: Name: JAYSON PEREDO Address: PO BOX 58991 , TUKW LA WA 98138 Phone: 253 486 -2392 Contractor: Name: ROHNER MECHANICAL INC Address: P 0 BOX 822049 , VANCOUVER WA 98682 Phone: 360 -885 -7641 Contractor License No: ROHNEMI015LH DESCRIPTION OF WORK: INSTALLATION OF PREFABRICATED SPRAY BOOTH/OVEN doc: IBC -10/06 Citl..af Tukwila �. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Value of Construction: $12,000.00 Fees Collected: $432.35 Type of Fire Protection: SPR]NKLER/DRY CH International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0024 * *continued on next page ** Permit Number: D07 - 364 Issue Date: 10/08/2007 Permit Expires On: 04/05/2008 Expiration Date: 05/17/2008 D07 -364 Printed: 10 -08 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: Signature: doc: IBC -10/06 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Number: D07 -364 Issue Date: 10/08/2007 Permit Expires On: 04/05/2008 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erformance of work. I am authorized to sign and obtain this development permit. Date: — oq-07 Print Name: Ta ( S o .1 6°,6,-, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -364 Printed: 10 -08 -2007 Parcel No.: 0223400042 Address: Suite No: Tenant: 355 TRECK DR TUKW MAACO SPRAY BOOTH 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: D07 -364 ISSUED 09/17/2007 10/08/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D07 -364 Printed: 10 -08 -2007 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. I 5 'so4 �[rta Date: t 0 — r71 007 -364 Printed: 10 -08 -2007 Site Address: Tenant Name: A CITY OF TUKWI4A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 35s T /ECk- Dri co Property Owners Name: t7e /Cr {r' pc- erg i-ef / /� G Mailing Address: P gat' 5 3 2— ' " City CONTACT PERSON — who do we contact when your permit is ready to be issued Name: (7 JOT) Pe /~-"Pdo Mailing Address: ei dk 5er 9/ E -Mail Address: l 4�4J p ` 377 e ' ` „ OT/ a / / IQf�J V GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) V101---A04 King Co Assessor's Tax No.:1 22 3 q O a f t/ 203 Suite Number: Floor: New Tenant: IX Yes ❑..No State ZNumberggs C 70 3 / 7er gro Zip Day Tel 2 434. ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: D4 V / u k 'e h / -e, / rr ch / (4 ,14_ / Mailing Address: ` /�{o Ban air z2 ve S� (e -`'e Q 7 . /f City State Contact Person: Da kZ /(.eh Day Telephone: 2- d 69 a 3 3 g qPq 7 E -Mail Address: vl I<Gh /'e Co / &h /'e a rCh. Corn Fax Number: '2-4 24 0 r� 7 ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip City Contact Person: Day Telephone: Fax Number: E -Mail Address: Q: Applications\Fonns- Applications On line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Page 1 of 6 BUILDING PERMIT INFORTION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ I 2109° Existing Building Valuation: /a $ Scope of Work (please provide d iled information): /ate? //Ql7'a1 d 7 a ,g/77� /_ /Ccz& spr boor oYl Will there be new rack storage? ❑ Yes Xr. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DMSION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: t o Sprinklers ❑ Automatic Fire Alarm ❑ None IN Other . ify) 1)eY C Clo .n1 c.�I t Will there be storage or use of flammable, combustible or hazardous materials in the building? .. Yes ❑ No booms If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quart: • nd Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:UppliuUons\Forms- Applications On line\ -2006 - Permit Application.doc Revised: 9 -2006 bh ��- 2(P Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor LJ /0j / 1 ) .J'/ / 'r \1 (L- -t'/1 2 {'l !� r-, �!f 2 " Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORTION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ I 2109° Existing Building Valuation: /a $ Scope of Work (please provide d iled information): /ate? //Ql7'a1 d 7 a ,g/77� /_ /Ccz& spr boor oYl Will there be new rack storage? ❑ Yes Xr. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DMSION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: t o Sprinklers ❑ Automatic Fire Alarm ❑ None IN Other . ify) 1)eY C Clo .n1 c.�I t Will there be storage or use of flammable, combustible or hazardous materials in the building? .. Yes ❑ No booms If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quart: • nd Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:UppliuUons\Forms- Applications On line\ -2006 - Permit Application.doc Revised: 9 -2006 bh ��- 2(P Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm/Ind MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: R-0 h1 A/612._ n /' Mailing Address: 1 2-414 6 ,V E Go O "h L 61D4 8 Van car Ve lot 9'J 4g City State Zip / . Day Telephone: 3(0e) cc) 7l E -Mail Address: ve.S f }art Ito H US4. Clax N 33(v0 � 57 If 1 Contractor Registration Number: i Q /'EM X- (J / 5 L N Expiration Date: 5/ / 7 / 26 0 8' Contact Person: Da- ve S7 --k-e2 1'1 Valuation of Mechanical work (contractor's bid price): $ 1- 0 0 _ Scope of Work (please provid detailed information): 1? 9 / /afl e> �/17C Q pre- fa6f-7 Spray 656A/0 Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Q:Upplications\Porms- Applications On linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh Fuel Type: Electric ❑ Gas ....' Other: Indicate type of mechanical work being installed and the quantity below: Page 4 of 6 BUILDING 0 Signature: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. R OR AUTFRIZED AGENT: A' Date Application Accepted: i a arl '-erede Print Name: D1 p q Mailing Address: 7 U 5.0>c 5-O / 9 / 7ikt,r, ` c Q: Applications\Forms- Applications On line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: Day Telephone: 2 i f &0 Z3q 2 &(/;rt City State Zip Date Application Expires: Mr4-1(01- Staff Initials: Page 6 of 6 Parcel No.: 0223400042 Address: 355 TRECK DR TUKW Suite No: Applicant: MAACO SPRAY BOOTH Receipt No.: R07 -02192 Payee: PEREDOS INC TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: WER Payment Date: 10/08/2007 10:22 AM User ID: 1655 Balance: $0.00 Amount Payment Check 2003 263.80 Account Code Current Pmts 000/322.100 259.30 000/386.904 4.50 Total: $263.80 Permit Number: D07 - 364 Status: APPROVED Applied Date: 09/17/2007 Issue Date: Payment Amount: $263.80 doc: Receipt-06 Printed: 10 -08 -2007 Doc: RECSETS -06 RECEIPT NO: R07 -01993 User ID: 1165 Payee: PEREDOS LLC SET TRANSACTIONS: Set Member Amount D07 -364 168.55 M07 -197 36.39 TOTAL: 204.94 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT Initials: JEM Payment Date: 09/17/2007 SET ID: S000000852 SET NAME: MARCO 000/345.830 TOTAL: Total Payment: 204.94 Amount Payment Check 2002 204.94 TOTAL: 204.94 Account Code Current Pmts 204.94 204.94 s -/ii ; TOTAL 1, 2 snr. Lip ?,1 09/17 .�-� Project: A A A A 64 /V1 Type of Inspection: 4J�J l l t• / -N...., J' it A t ' Address: ?jS /1P / /3 . Date Called: Special Instructions: Date Wanted: 0 < a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 \1206)431- Approved per applicable codes. Corrections required prior to approval. 2z COMMENTS: � y � ( Inspector: (Date: Z . l� 0 $58.00 REINSPECTION FEE REQUIR 'ED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: 4/14 /9 S P1'?116/ Type of Inspection: 7 c -- 4/17/ Address: _ass 7.- ,2( ( //, .D2 Date Called: .._ Special Instructions: Date Wanted _ b (a,n- Requester: Phone No s.3. / - �3S`z INSPECTION RECORD </ etain a copy with permit DD 7= C INSPE 10 NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C?, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Dat $ 7 0 REINSPECTION F REQUIRE . Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: This authorizes the application of the Certification Marks shown below to the Product Covered (also to the multiple listee model identified on the correlation page of the Listing Report where applicable) when made in accordance with the Description and under the conditions set forth in the Certification Agreement and Listing Report: Applicant: Contact: Party Authorized To Apply Mark: Reference Report No.: Report Issuing Office: Product Covered: Description: Standard(s): FILE COPY AUTHORIZATION TO MARK Gannat USA Inc. 1401 W. Stanford Ave Englewood, CO 80110 Intertek Testing Services NA Inc. Manufacturer: Same as Applic John Jurasic (303) 781— 6802, Fax (303) 781 - 2683 Same as Applicant 3054850 -003 Cortland HVAC, 3933 US Rt. 11, Cortland NY, 13045 Products covered are direct fired heaters, model numbers — 46008, 46008X, 48106, 48106X I REVIEWED FOR CODE COMPLIANCE APPROVED C BUILD SEP 2 8 2 Of Tu 7 wila The product covered by this report is a paint spray booth that has a ventilation system interlocked to the spray application equipment. The paint spray booth incorporates a natural gas.Direct Gas Fired Heater that is an integral part of the paint spray booth cabin. The product is provided with a Listed Industrial Control Panel, and Listed Electric Lighting Fixtures for Usc in Hazardous Locations. The paint spray booth is fully automated with Spray and Bake Cycles of operation. The paint spray booth is permanently connected to the electrical supply source. The heater pre- conditions the incoming air to a maximum of 200 F. and is connected thriSugh permanently installed ducting. The exhaust ventilation is also connected through permanently installed ducting to a safe discharge location. • Fuels — Natural Gas. • Unit Configuration — Down Flow, Blow Through • Discharge Configuration — Horizontal • Clearances to Combustible Material — 4" from top, sides and ends. (For service clearances, the distance of the door opened to 90 degrees is used.) • For installation on Combustible Surfaces. Non - Recirculating Direct Gas -Fired Industrial Air Heaters ANSI 283.4- 1999•CSA 3.7 -M99 ( Revisions through 10/01/99 w/ Addenda A — 2001, and Addenda B -2002) Thisprocedure, with all revisions, etc., is the property of lntertek Testing Services and is intended solely for the guidance of the listee and the representative of Intertek Testing Services, and is not transferable. Issued by: Intertek Testing Services NA Inc. 165 Main Street Cortland, NY 13045 -2014 USA ra --/ 9` . ry rLik _ EGG f Authorized by: '' Dom �! � v , RECEIVED William T. Starr GTY OF TUIC 1 Certification Manager SEP 17 2007 PERMIT CENTER Control Number: (40f,-1 Intertek Testing Services NA Inc. Report No. 3054850 -003 REVISION PAGE Issued: 4/26/04 Garmat USA Inc. Revised: 09/15/04 Report Composition: Numbering Cover 1 Revisions Revision Page Main Report 2 -16, 16A, 17 -39 Illustrations 33 -39 Markings 40-42 Components Requiring Yearly Testing 43-44 Total Number of Pages 45 Total Pages in this Report: 45 Note: When additional pages have been added after issuing, such as "A" or " -1" pages, they should be noted in the table above. For example: main report 1 -5, 5A, 5B, 6 -10, 10-1, 11 -15. REVISION SUMMARY - The following changes have been made to this Report: Date /Project # Project Reviewer Elge Item Description of Change 9/15/04 Allen Pirro Cover Added rev level of standard. 3061665 2 Addition of New Models to Model Series M.Sgyr 4 3 Updated ratings table to show new models 5 Added rev level of standard. �/ 11 Added models to multiple listee g ie2 /6J 12 Added models to multiple listee 13 Added models to multiple listee 14 Added photos to photo index I6A Added additional listed control panels. 25 Added photo of gas tram for 42xxx and 48xxx models 26 Added components for 42xxx and 48xxx models 27 Added photos of burner for 42xxx & 48xxx models 28 Added components for 42xxx and 48xxx models 29 Added photo of exhaust motor for new models 30 Added components for 42xxx and 48xxx models 31 Added photo of controller for new models 32 Added components for 42xxx and 48xxx models 33 Moved from original pg 25 and added new illustrations 34 Moved from original pg 26 35 Moved from original pg 27 36 Moved from original pg 28 37 Moved from original pg 29 38 New Illustration added 39 New Illustration added 40 Moved from original pg 30 41 Moved from original pg 31 42 Moved from original pg 32 43 Moved from original pg 33 44 Moved from original pg 34 NOTE: When the Report is first issued, the Revision Page will say "None." under the description of revisions made. Applicant: Intertek Testing Services NA Inc. LISTING REPORT INTERTEK TESTING SERVICES NA INC. 3933 US Route 11, Industrial Park Cortland, NY 13045 Job No. 3034850 -421 Issued: 04 /26/04 Revised: 09/15/04 Garmat USA Inc. 1401 W. Stanford Ave. Englewood, CO 80110 Manufacturer: Same as Applicant REPORT NO. 3054850 -003 INSPECTION, TESTS AND EVALUATION OF A Nonrecirculating Direct Gas -Fired Heater RENDERED TO Garmat USA Inc. Englewood, CO GENERAL: This Report gives the results of the inspection, tests and evaluation of a family of Direct Fired Heaters for compliance with applicable requirements of the Standard for Non - Recirculating Direct Gas -Fired Industrial Air Heaters ANSI Z83.4-1999, CSA 3.7 -M99 ( Revisions through 10/01/99 w/ Addenda A — 2001, and Addenda 13- 2002). The investigation to certify the 88000 model series was authorized by po # 20919. Signed by John S. Jurasic. The investigation for the 99270 model series was begun on 11/21/03 and completed on 04/26/04. A production sample, a model number 46008 in good condition, was provided by the client and tested at the 1TS's Cortland, NY facility. Non - Recirculating Direct Gas -Fired Industrial Air Heaters ANSI 283.4- 1999•CSA 3.7 -M99 ( Revisions through 10/01/99 w/ Addenda A — 2001, and Addenda B -2002) Contact: Contact: John Jurasic (303) 781 6802, Fax (303) 781 - 2683 An Independent organization testing for safety, performance, and certification. This report is for the exclusive use of ITS's Client and is provided pursuant to the agreement between ITS and its Client. ITS's responsibility and liability are limited to the terms and conditions of the agreement. ITS assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the ITS name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by ITS. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an ITS certification program. Model Midco HMA -2 42010 500,000 42010X 500,000 42106 500,000 42106X 500,000 46008 500,000 46008X 500,000 48106 500,000 48106X 500,000 Midco HMA -2 Area 12" Straight Back Inlet, H -1361 .65 Sq. Ft. Intertek Testing Services NA Inc. Report No. 3054850 -003 Page 2 Issued: 426/04 Garmat USA Inc. Revised: 09 /15/04 PRODUCT DESCRIPTION PRODUCTS COVERED: Products covered are direct fired heaters, model numbers — 42010, 42010X, 42106, 42106X, 46008, 46008X, 48106, 48106X PRODUCT DESCRIPTION The product covered by this report is a paint spray booth that has a ventilation system interlocked to the spray application equipment. The paint spray booth incorporates a natural gas or propane (LPG) Direct Gas Fired Heater that is an integral part of the paint spray booth cabin. The product is provided with a Listed Industrial Control Panel, and Listed Electric Lighting Fixtures for the in Hazardous Locations. The paint spray booth is fully automated with Spray and Bake Cycles of operation. The paint spray booth is permanently connected to the electrical supply source. The heater pre-conditions the incoming air to a maximum of 200 F. and is connected through permanently installed ducting. The exhaust ventilation is also connected through permanently installed ducting to a safe discharge location. • Fuels — Natural Gas. LP Gas (LP gas noted through "r designation at the end of the model number) • Unit Configuration — Down Flow, Blow Through • Discharge Configuration — Horizontal • Clearances to Combustible Material — 4" from top, sides and ends. (For service clearances, the distance of the door to 90 degrees is used.) • For installation on Non - Combustible Surfaces. MODEL SIMILARITY All models within the model line are manufactured using the same style cabinet in varying sizes. The burner in a 42000 model series may vary from to three feet of burner length. To verify the proper velocity over the burner use the following relationship: Burner shadow area = Length of burner x (See Table A for Burner Area's) Profile area (sq. in.) _ I(CFM + profile velocity) + burner shadow area] x 144 = Length of profile x width of profile. Velocity over the burner(flhnln) = Unit CFM divided by (profde area — burner shadow area) Firine Rate ( btu/hr per linear foot of burner Table A Modell: Volts/Hz/PH Fan (Exhaust) Fan (Supply) x 2 Total Air Throughput Temp. Rise °F Minimum Ambient °F Input Btu/hr Midco HMA-2 Amps HP Amps HP Amps CFM Nat/LP Natural 42010 208/230/460/60/3 1.7/1.5/0.80 1/ 13.8/13.4 5 20120/ 10 10,000 80 F 20 F 997,000 3 /6.7/5.4 42010X 208/230/460/60/3 1.7/1.5/0.80 1/ 13.8/13.4 5 2020/ 10 10,000 80 F 20 F 997,000 3 /6.7/5.4 42106 208 / 230/460/575/60/3 283/28.4/14.2/ 10 21.4/20./ 7.5 56.1/55.2! 11,000 80 F 20 F 997,000 11.4 10.2/ 27.6/22.2 82 42106X 208/230/460/575 /60/3 28.5/28.4/14.2/ 10 21.4120✓ 7.5 56.1/552/ 11,000 80 F 20 F 997,000 11.4 10.2/ 27.6/22.2 8.2 46008 208/230/460/575 /60/3 28.5/28.4/14.2/ 10 13.8/13.4 5 56.1/5521 12,000 80 F 20 F 997.000 11.4 /6.7/5.4 27.6/22.2 46008X 208/230/460/575 /60/3 28.528.4/14.2 10 13.8/13.4 5 56.1/55.2/ 12,000 80 F 20 F 997,000 11.4 /6.7/5.4 27.6/22.2 48106 208/230/460 /575/60/3 21.4/20.4/10.2/ 7.5 21.4/20J 7.5 56.1 /55.2/ 11,000 80 F 20 F 997,000 8.2 10.2/ 27.6/22.2 82 48106X 208/230/460/575 /60/3 21.420.4/10.2/ 7.5 21.420./ 7.5 56.1/552/ 11,000 80 F -20 F 997,000 8.2 10.2/ 27.6/22.2 82 Report No. 3054850 -003 Garmat USA Inc. RATINGS Intertek Testing Services NA Inc. Page 3 Issued: 426/04 Revised: 09/15/04 Report No. 3054850 -003 Garmat USA Inc. Intertek Testing Services NA Inc. Page 4 Issued: 05/13/04 TEST PERFORMANCE A representative sample of the products was tested in accordance with the Standard for N n- Recirculating Direct Gas -Fired Industrial Air Heaters ANSI Z83.4- l999•CSA 3.7 -M99 and the requirements of Addenda (a), ANSI Z83.4a•2001•CSA 3.7a -2001. The following tests were performed: Description Standard(s)/Clause Air Throughput Measurement Z83.4 / 2.5 High Temperature Limit Control System Z83.4 / 2.6 Air Flow Sensing System Z83.4 / 2.7 Operating Temperature Control System Z83.4 / 2.8 Combustion Z83.4 / 2.9 Burner Operating Characteristics Z83.4 / 2.10 Piloted Ignition Systems Z83.4 / 2.11 Manifold and Control Assembly Capacity Z83.4 / 2.15 Wall, Floor, Ceiling, Electrical Equipment and Wire Temps Z83.4 / 2.16 Electrical Continuity, Leakage and Dielectric Strength Z83.4 / 2.17 Heaters for Outdoor Installation Z83.4 / 2.18 Combustions Z83.4a / 2.9 Burner and Heater Input Ratings Determination Z83.4a / 2.15 Results of the tests indicate the specimens conform to applicable test criteria. Intertek Testing Services NA Inc. Report No. 3054850 -003 Page 5 Issued: 4/26/04 Gartnat USA Inc. Revised: 09/15/04 CONCLUSION Representative samples of the products covered by this report have been evaluated and found to comply with the applicable requirements of the Standard for Non - Recirculating Direct Gas -Fired Industrial Air Heaters ANSI Z83.4- 1999•CSA 3.7 -M99 (Revisions through 10/01/99 w/ Addenda A — 2001, and Addenda B -2002) Report ' • . . by: Project Engineer — HVAC Safety Report approved by: w Snyder, Al Pirro, Chief Engineer — HVAC Safety Report No. 3054850-003 Garmat USA Inc. Intertek Testing Services NA Inc. Page 6 Issued: 4/26/04 GENERAL INFORMATION The Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify ITS and to request authorization prior to using alternate parts, components or materials. COMPONENTS: Components used shall be those listed in the ITS report covering the products specified in the index including any amendments and/or revisions. LISTING MARK: The ETL listing mark applied to the products shall either be separable in form, such as labels purchased from ITS, or on a product nameplate or other media only as specifically authorized by ITS. Use of the listing mark is subject to the control of ITS. MANUFACTURING AND PRODUCTION TESTS: Manufacturing and Production Tests shall be performed as required in this Report. FOLLOW -UP SERVICE: Periodic unannounced audits of the manufacturing facility shall be scheduled by ITS. An audit report shall be issued after each visit. Special attention will be given to the following: 1. Conformance of the manufactured product to the descriptions in this Report. 2. Conformance of the use of the ETL mark with the requirements of this Report and the Listing, Labeling, and Follow -up Service Agreement. 3. In -plant quality control procedures and personnel. 4. Manufacturing changes. 5. Performance of specified Manufacturing and Production Tests. In the event that the ITS representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions: 1. Correct the non - conformance. 2. Remove the ETL Listing Mark from non - conforming product. 3. Contact the issuing product safety evaluation center for instructions. RATINGS MINIMUM SPACING mm an) _ THROUGH MR OVER SURFACE TO ENCLOSURE VA VOLTS mm in mm in mm in 0-2000 0-300 3.2 1/8 63 ''A 6.3 1/4 Hi 0-150 3.2 1/8 6.3 54 12.5 'A 151 -300 6.3 1/4 9.5 3/8 12.5 'A 301 -750 9.5 3/8 12.5 'A 12.5 1 /4 Report No. 3054850 -003 Gannat USA Inc. 1. Intertek Testing Services NA Inc. Page 7 Issued: 4/26/04 GENERAL REQUIREMENTS AND DEFINITIONS Recognized - Identifies any component, part or subassembly covered under the recognition service of an NRTL (US) or a CO (Canada) and intended for use in ETL Listed, ETL Classified, or ETL Recognized products. 'Listed - Identifies any product covered under the Listing or Certification service of an NRTL (US) or a CO (Canada). Construction Details - For specific construction details, reference should be made to the following photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply. $patinas - In primary circuits, the following spacings are maintained through air and over surfaces of insulating material between current- carrying parts of opposite polarity and between current - carrying parts and dead -metal parts. 2. Mechanical Assembly - Components such as switches, fuseholders, connectors, wiring terminals and display lamps are reliably mounted and prevented from shifting or rotating by lockwashers, starwashers, or the mounting format. 3. Corrosion Protection - All ferrous metal parts are suitably protected against corrosion by painting, plating or the equivalent. 4. Grounding - All exposed dead -metal parts and all dead -metal parts within the enclosure that are exposed to contact during any servicing operation and that are likely to become energized are reliably connected to the equipment ground connector. 5. Current Carrying Parts - All current - carrying parts in primary circuitry are silver, copper, or copper based alloy. Intertek Testing Services NA Inc. Report No. 3054850 -003 Page 8 Issued: 4/26/04 Garmat USA Inc. 6. Internal Wiring - Internal wiring is reliably muted away from sharp or moving parts. Internal wiring leads terminating in soldered connections are made mechanically secure prior to soldering. Separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is protected against abrasion or damage by plastic bushings or grommets. All wiring has a minimum rating of 300V, 105 C. 7. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a metal enclosure constructed such that any openings are not penetrable by the probe specified in the above - referenced Standard. 8. Markings - The unit is marked with the manufacturer's name, model number, electrical ratings, date of manufacture and cautionary markings where required. Markings are provided in English and French. Please refer to Marking pages for details. 9. Installation. Operating and Safety Instructions - Instructions for the proper installation and safe use of this product are provided by the manufacturer. Manual number MUAIM -1 must be provided with the DFC and DFM, manual number DFLIOM -1 must be provided with the DFL models. Intertek Testing Services NA Inc. Report No. 3054850 -003 Page 9 Issued: 4/26/04 Garmat USA Inc. MANUFACTURING AND PRODUCTION TESTS The manufacturer shall check, inspect, and test the components and the assemblies of each heater in the following manner. a. Inspect raw materials and purchased components. b. Inspect each burner to determine conformance with manufacturing specifications by application of a visual inspection. c. Test fire each burner and manifold and control assembly for the proper burner and gas valve operation and verify the gas tightness of the manifold and control assembly. This test shall be conducted on completely assembled heaters, when feasible. d. Test each heater to determine that electrical components function properly. This test shall be conducted on completely assembled heaters, when feasible. e. Conduct Dielectric Voltaire Withstand Tests on each factory assembled heater incorporating high- voltage electric circuits. See Dielectric Voltage Withstand Test procedure sheet for details on conducting test. One unit of production shall be tested annually to determine satisfactory operation with respect to: a. Burner Operating Characteristics; b. Ignition systems and pilot safety shutoff devices; c. Combustion; d. High temperature limit control; and e. Airflow sensing system. The results of these tests shall be recorded and maintained by the manufacturer for review by the certifying agency. Test Potential Test Time <250 V, < 'Y2 HP unit >250 V, >''A HP unit 1000 V 1000 V+ 2 x rated voltage 1 minute 1200 V 1200 V+ 2 x rated voltage 1 second Intertek Testing Services NA Inc. Report No. 3054850 -003 Page 10 Issued: 4/26/04 Garmat USA Inc. Method Products Requiring Dielectric Voltage Withstand Test: All products covered by this Report DIELECTRIC VOLTAGE WITHSTAND TEST: One hundred percent of production of the products covered by this Report shall be subjected to a routine production -line dielectric withstand test The test shall be conducted on products which are fully assembled. Prior to applying the test potential, all switches, contactors, relays, etc., should be closed so that all primary circuits are energized by the test potential. If all primary circuits cannot be tested at One time, then separate applications of the test potential shall be made. The test potential specified below shall be applied between primary circuits and accessible dead-metal parts. The test potential may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required. Test Equipment The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown. The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA. If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either: 1 - a voltmeter in the primary circuit; 2 - a selector switch marked to indicate the Lest potential; or 3 - a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output. In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration. 06 -05 -2008 JAYSON PEREDO PO BOX 58991 TUKWILA WA 98138 RE: Permit No. D07 -364 355 TRECK DR TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/23/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, f er Marshall Permit Technician xc: Permit File No. D07 -364 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: D07 -364 DATE: 09 -17 -07 PROJECT NAME: MAACO SPRAY BOOTH SITE ADDRESS: 355 TRECK DR X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Issued Response to Correction Letter # DEPARTMENTS: Build g Di ision Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ../PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 61‘ 4w0 Fire Prevention LL Structural ❑ Incomplete ❑ TUES/THURS RO ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved with Conditions No further Review Required DATE: DATE: Planning Division Permit Coordinator C n DUE DATE: 09-18-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 10-16-07 Not Approved (attach comments) C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Printer Friendly Version ve Date6/8/1999 rtp iration rate = 5/17/2008 Suspend Date Separation Date Parent Company Previous License Next License °= VAUGHPC974NO Associated, License •, ... �ii� iuii v1 1 1111111/GI License uetali ToQi+ tnciex Contact trif o Look Up a Contractor, Electrician or Plumber Li cens e; ROHNEMI015LH .......... Licensee Name, ROHNER MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBi 601952807 Verify Workers Comp Premium Status nd. Ins. Ac ou nt I Business Type CORPORATION Address 1.( PO BOX 822049 Address City; VANCOUVER County 1 CLARK State tel WA Ptt ape 3608857641 Stat ACTIVE Specialty 1 GENERAL Specialty; 2 UNUSED A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. hops: // fortress .wa.gov /lni /bbip /Detail.aspx ?License= ROHNEMI015LH Page 1 of 2 10/8/2007 r I rill irir AIWA/IA! I 4 PREFABRICATED PANT BOOTH 8 _I 32'-0" 21' •0" MINNA NM CI= MIIII OM= 2T-0" HALL EXIST MEN EXIST. EXIST. ELECTRICAL EXIST. NO STAIR 4 LANDING (STING 6 1/4" CONCRETE t iEX WALL ALONG GRIDLNE C, ALL OTHER EXTERIOR WALL 5 IR " CONCRETE TYPICAL 12' -b 21"..6 12' ' -0 )e 3 ' =0" XISTNG IN- FILLED OPENING SEMI-HEATED SPACE MAX S B1U/HR NO ELECTRIC RESISTANT +4ATNG 12' - 0" LOCK EXISTING OVERHEAD DOOR 5co,e dr work p W48 FLOOR PLAN 1/8"=1:—O'' SHOP 5 EXISTM STAIR NO WOW €4- Q EXISTING SPRINKLER RISER Exist. WOOD STUD SHEAR WALL, NO CHANGE EXIST. STAIR 4 LANDING NO CHANGE BY CONCRETE STAIRS 4 LANDING f)013 REVISIONS No changes shall made o the scope of Work without prior ap royal of Tukwila Building Dig ision. � NOTE: Revisions wiarequire l ply n review fees. I and may include - Mi Permit Noe pal- Ran review r °_ravel is subject 10 errors and ornissl Approval c` c `- ctian documents does not author the violot. ::i c' c. -./ ccca; Zed code or ordinanc.m. Receipt apprcycil r . .� 1 C:77 ` , :d condition, is ocknoi 'Wedgeda Date: tw City of Tukwila ILDING DIVISION 3T -6' NEW CONCRETE WHEELCHAIR RAMP . ..o■- -. - d__.. ...� 1 SEE SHEET T -3 FOR ENLARGED PLAN OF THIS 41 KEY PLAN N.T.S. UJ14LL TYPE SCHEDULE A B E1 : E3: E4: E E6: 142: 344: 5/8" GYP. 130. BON SIDES 3 5/8 1 525 GA STEEL STUDS • 24" 0.0. FROM FLOOR TO UNDERSIDE OF EXISTIN G SUSPENDED CEILING. FILL IN EXISTING OPEN(13 W/ ONE -HOUR ASSEMBLY, 5/S' GYP. ED. BON SIDES STEEL STUDS + 24" O.C_ FINISH &MOON 4 FLUSH W/ ADJACENT EXISTING SURFACES. INSTALL. PER GA FILE'XOOOOGC. 5/8' GYP. BD. BON SIDES 3 5/5")C GA. STEEL STUDS • 24' O:C. FROM FLOOR TO UNDERSIDE CF CEILING • 1I' -0" APE, ONE -HOUR ASSEMBLY FER GA FILE 'X XXXXX. DooR SCHEDULE EXIST. PAIR 3701' ALUMINUM STOREFRONT DOORS W/ CLOSER THRESHOLD, WEATHERSTRIPPING, LOCK, 4 SAFETY GLAZING, NO CHANGE. E2 : EXIST 35(1' ALUI1M1<1 STOREFRONT DOOR CLOSED, LOCK, 4 SAFETY GLAZING, NO GUNGE. EXIST. 3X1' WOOD W/ METAL JAMB, NO CIaANGE. EXIST. 37X1' WOOD DOOR 4 JAMB, NO CHANGE. EXIST. 37X1' HOLLOW METAL DOOR 4 JAMB W/ CLOSER LOCKSET, WEATHERSTRIPPNG, 4 THRESHOLD, NO CHANGE. EXIST.10'XI0' OVERHEAD DOOR NO CHANGE. 37X1' HOLLOW METAL DOOR 4 JAMB W/ 1 1P2 PAIR BUTTS, CLOSER LATCHSET, SMOKE GASKET, THRESHOLD, ONE -HOUR RATED. 351' SOLID CORE DOOR 4 JAMB W/ 11/2 PAIR BUTTS, CLOSER 4 LATCHSET. ROOM SCHEDULE ROOMS 12,43: FLOORIPKs - CARPET BASE - 4" RUBBER EASE WALLS - PAINTED GYP. E. CEILING - EXISTING 2'X4' SUSPENDED ACOUSTICAL ROOM 4 FLOORING - VCT BASE - 4" l JBBER EASE WALLS - PAINTED GYP. BD. CEILING - EXISTING 2'X4' SUSPENDED ACOUSTICAL ROOM 5: FLOORING - SEALED CONCRETE BASE - NONE WALLS - PANTED GYP. ED. 4 CONCRETE CEILING - EXPOSED STRUCTURE I INSULATION ROOM b: FLOORING - SEALED CONCRETE BASE - NONE WALLS - PANTED GYP? ED. CEILING - PAINTED GYP. BD. ROOM 1: FLOORING - SEALED ATE BASE - 4" RUBBER WALLS - PAINTED GYP. SD. CEILING - EXSTNG 2704' SUSPENDED ACOUSTICAL ROOMS S: FLOORING - SEALED CONCRETE BASE - NONE WALLS - FACTOR FINISH CEILING - FACTORY FINISH NOTE: NO CHANGE TO EXISTING HALL, ELECTRICAL ROOM, CLOSET, RESTROOMS OR ADJACENT 'TENANT SPACE RECEIVED CITY OF TUKWILA SEP 1 7 2007 PERMIT CENTER N O) 0) (0 Cn CO CO o D Cq CD CO 0 0 N N W 1— O >[ co W = < tl cri Li N—• ) a) Eraigi L,J c' s a ) C-) CONTROL GAS TRAIN LOCATION 25" X 25" DUCT 7.5 HP MOTORS PLAN VIEW EXTRACT y 10' -0 1/8" ENTRY ELEVATION NOT TO SCALE WALL OR OBSTACLE ACCESS DOOR NOTE: INSURE CLEAR INTERIOR CEILING HEIGHT TO ACCOM— MODATE EQUIPMENT. IGHT FIXTURE SIDE ELEVATION NOT TO SCALE 7.5 HP MOTORS INTAKE EXTRACT ISOMETRIC VIEW NOT TO SCALE 25" X 25" DUCT EXIT ELEVATION NOT TO SCALE 25" X 25" DUCT (8) FILTER RACK EXHAUST OPENIN NOT TO SCALE SPRAY BOOTH: 7.5hp MOTOR FILTERS: Booth Ceiling, Filtrair CC600 G media, 99.9% efficiency, thermally bonded and impregnated in full depth to prevent release of fibers and migration of particles larger than 5 microns. Booth Exhaust, Filtrair Paint Arestor, glass fiber media, 96.5% efficiency, 4 self — sealing racks located in each of the two exhaust towers. FANS: Booth Intake: 1 Dual 355 Spark Arresting Reverse Incline Fan with 7.5HP Motor. Booth Exhaust: 1 Single 450 Spark Arresting Reverse Incline Fan with 7.5 HP Motor. CFM: 10,000 FILTER ACCESS DOORS THE GARMAT 42106. 27' TIER 1 SPRAY BOOTH WILL REQUIRE: 1. AT ELECTRICAL DROP LIGHTING (14, 4 —TUBE INTERIOR ACCESSIBLE LIGHT FIXTURES) WILL REQUIRE TWO 120v, 20amp, SINGLE PHASE CIRCUITS STANDARD, OR TWO 277v,10amp SINGLE PHASE CIRCUITS OPTIONAL. UPGRADED LIGHTING WILL REQUIRE AN ADDITIONAL LIGHT CIRCUIT. 2. AT ELECTRICAL DROP THE MOTORS WILL REQUIRE 208/240/480v(575 OUTSIDE OF USA), 60/60/30amp, THREE PHASE SERVICE FOR TWO 7.5hp MOTORS STANDARD. 3. ALL ELECTRICAL CONNECTIONS SHOULD BE IN ACCORDANCE TO THE CURRENT NEC (NATIONAL ELECTRICAL CODES). VERIFY COMPLIANCE OF LOCAL CODES WITHIN THE JURISDICTION OF THE INSTALLATION SITE. 4. ALLOW ADEQUATE CLEARANCE OF 3' MINIMUM FROM ALL SPARKING ELECTRICAL COMPONENTS, TO CONFORM TO THE CURRET NFPA (NATIONAL FIRE PROTECTION ASSOCIATION) 33, EDITION. 5. REMOTE CONTROL PANEL TO BE PLACED WITHIN 20' OF MAIN ELECTRICAL PANEL AND NOT TO BE WITHIN 3' OF A BOOTH OPENING, IN COMPLIANCE WITH THE CURRENT NEC EDITION. 6. SUPPLY 100 PSI COMPRESSED AIR TO MAIN GARMAT CONTROL PANEL, INCLUDING SHUT OFF VALVE (NOT SUPPLIED). CLEAN AND DRY AIR IS REQUIRED BEFORE THE SPRAY BOOTH CONTROL PANEL. A QUALITY AIRLINE DRYER (NOT SUPPLIED) CAPABLE OF A CONSTANT 17 CMF SHALL BE INSTALLED PRIOR TO MAIN CONTROL PANEL. AN ADEQUATE PRESSURE REGULATOR (NOT SUPPLIED) CAPABLE OF A CONSTANT 17 CMF AT 60 PSI IS RECOMMENDED PRIOR TO ENTERING THE SPRAY BOOTH CABIN (DO NOT MOUNT REGULATORS OR AIR FILTERS INSIDE THE BOOTH CABIN). 7. BURNER SIZE: 997,000 btu 8. SUPPLY GAS PIPING TO GAS TRAIN, INCLUDING UNION AND DRIP LEG (1 1/4" CONNECTION AT GAS TRAIN INLET). (RECOMMENDED DEDICATED LINE FROM METER WHEN POSSIBLE). GAS PRESSURE MUST BE A MINIMUM OF 1/4" psi (7" w.c.) AND A MAXIMUM OF 3/4" psi (21" w.c.). CAPACITY TO PROVIDE FOR 997,000 BTU BURNER. VENTING OF REGULATOR AND VALVES ON GAS TRAIN TO THE EXTERIOR OF BUILDING -- MINIMUM OF 10' FROM INTAKE. 10. ALLOW ADEQUATE SPACE AROUND THE BOOTH IN ACCORDANCE TO THE CURRENT NFPA 33, EDITION. 11. MEANS OF EGRESS TO CONFORM TO THE CURRETN NFPA 101, EDITION. 12. A MINIMUM CLEARANCE OF 20' IS REQUIRED FROM FRONT OF THE BOOTH TO ANY WALL OR OBSTACLE FOR OPTIMUM TURNING RADIUS. 13. HEIGHT OF BOOTH IS 11'-2 3/8 ". HIGHEST POINT IS 12' -4 1/4 ". INSURE 13' CLEARANCE AT ALL MOTOR AND DAMPER LOCATIONS. 14. PROVIDE FOR UNOBSTRUCTED EXPLOSION RELIEF IN ACCORDANCE TO THE CURRETN NFPA 86, EDITION. 15. AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM SHALL BE PROVIDED BY OTHERS. IN ACCORDANCE TO THE CURRENT NFPA 33, EDITION. LEGEND e ELECTRICAL DROP M MOTOR LOCATION INLET AIR FLOW TO BOOTH CABIN FROM MECH- ANICAL UNIT 0 GAS TRAIN INLET Q 2' -1" x 2' -1" INTAKE OPENING a 2' -1" x 2'--1" EXHAUST OPENING CAROL NELSON Drawn by: Approved by: Copyright © 2007 GARMAT USA. INC This drawing is not to be reproduced, either in whole or in part without the permission of Garmat USA, Inc. FAX (303)781 -2683 PHONE (303)781 -6802 1401 W. STANFORD AVE. ENGLEWOOD, CO 80110 STATUS — SOLD REVISION — 0 SHEET SIZE — D DRAWING NO. ROM 015A0