HomeMy WebLinkAboutPermit D07-379 - COMPUPAY - TENANT IMPROVEMENTCOMPUPAY
545 ANDOVER PK W
D07.379
Parcel No.: 2623049144
Address: 545 ANDOVER PK W TUKW
Suite No:
Tenant:
Name: COMPUPAY
Address: 545 ANDOVER PK E , TUKWILA WA
doc: IBC -10/06
Cityf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Owner:
Name: SOUTBCENTER CORPORATE SQUAR
Address: 150 CALIFORNIA ST , SAN FRANCISCO CA 94111
Phone:
Contact Person:
Name: TAMARA GENZALE
Address: 635 ANDOVER PK W, STE 107 , TUKWILA WA 98188
Phone: 206 575 -3080
Contractor:
Name: D P INC GENERAL CONTRACTORS
Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155
Phone: 206 -361 -2989
Contractor License No: DPINCGC066BU
DEVELOPMENT PERMIT
Permit Number: D07 - 379
Issue Date: 10/30/2007
Permit Expires On: 04/27/2008
Value of Construction: $40,000.00 Fees Collected: $1,114.59
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006
Type of Construction: VB Occupancy per IBC: 0008
Expiration Date: 01/31/2008
DESCRIPTION OF WORK:
TENANT IMPROVEMENT - DEMOLITION AND CONSTRUCTION OF PARTITIONS, DOORS, AND OTHER FEATURES.
* *continued on next page **
D07 -379 Printed: 10 -30 -2007
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
City G./Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non- Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Print Name:
doc: IBC -10/06
w AL
c\rokoopvl 11 W
Permit Number: D07 -379
Issue Date: 10/30/2007
Permit Expires On: 04/27/2008
Date: l.0 o7
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or e erformance of work. I am authorized to sign and obtain this development permit.
Signature: /\ C & / V A/\/ t Date:
(
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
D07 -379 Printed: 10 -30 -2007
Parcel No.: 2623049144
Address:
Suite No:
Tenant:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
545 ANDOVER PK W TUKW
COMPUPAY
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
D07 -379
ISSUED
10/03/2007
10/30/2007
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
7: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet
in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and
calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State
of Washington.
9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
10: Remove all demolition nibble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
12: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum
distance of 4- inches shall be maintained above the controls with the strapping.
13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206 - 431 - 3670).
doc: Cond -10/06
D07 -379 Printed: 10 -30 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
16: ** *FIRE DEPARTMENT CONDITIONS * **
17: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4-3, 4-4)
23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
28: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
doc: Cond -10/06
D07 -379 Printed: 10 -30 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
29: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
30: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H
occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit panic hardware on rated
fire doors. (IFC 1008.1.9)
31: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3)
32: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
33: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
34: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2051)
36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
37: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this
project.
38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
40: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite,
room or apartment number in a conspicuous place near the main entry door. (IFC 505.1)
41: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
doc: Cond -10/06
D07 -379 Printed: 10 -30 -2007
#2051)
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
42: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed
description of intended use.
43: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
44: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
* *continued on next page **
007 - 379 Printed: 10 -30 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
D\ 1CI
Signature: Date: 31
Print Name:
doc: Cond -10/06
v1n ow\ror v 11
D07 -379 Printed: 10 -30 -2007
King Co Assessor's Tax No.:
Site Address : Qnt ? A.A_Y_
Tenant Name: C pa f ►A.
Property Owners Name:
Mailing Address:
Company Name:
Mailing Address:
Company Name: illQ 1'V S yi Vlssc tek n S
Mailing Address: LISA- a \ s . St +C
Contact Person: / 1 0—
' • II e
E -Mail Address: Le
Company Name:
Mailing Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: //www. ci. tukwila. wa. us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Pin r1(C ohbt3U
Contact Person:
E -Mail Address:
Q:Wpplications\Forms- Applications On LineV -2006 - Permit Application. doe
Revised 9 -2006
bh
Building Permit No.
Mechanical Permit No.
Plumbing /Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Suite Number: b1
New Tenant:
City
Day Telephone:
Fax Number:
Floor:
Yes
Contact Person: \`
E -Mail Address: 1 wp.... 6 1 VIC 10
Contractor Registration Number:
State
Expiration Date: ,SG n Oi
State
❑ ..No
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name:
Mailing Address:
E -Mail Address:
Day Telephone _go
a 1O,/., tl 11./.4 _
tk.a'.AA .
V..
. t
rate
'7 SOlo
City
Fax Number:
GENERAL CONTRACTOR INFORMATION —
(Contractor information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
LLC�
VOA 6 3%17 City State Zi p
Day Telephone: tdd- 4 I /
Fax Number: ?—a 041
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Zip
Cit
Day Telephone:
Fax Number:
Page 1 of 6
'It ISS
BUILDING PERMIT INFORMATION - 206 -431 -3670
Valuation of Project (contractor's bid price): VW xisting Building Valuation: $
Scope of Work (please provide detailed information): Q. 4-
2t
DID %M IAe .
Will there be new rack storage? ❑ Yes
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
'For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: V\
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTIONMAZARDOUS MATERIALS:
Is Sprinklers Bg Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 154 No
/f"yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q:1ApplicationsWonns- Applications On LineV •2006 - Permit Application.doc
Revised: 9 -2006
bh
i — No If yes, a separate permit and plan submittal will be required.
Compact:
Handicap:
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of ''
Construction per
IBC
Type of
Occupancy per
IBC.
l Floor
93S
r
2nd Floor '
10 331
3 Floor
Floors thru
Basement
Accessory Structure'
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
BUILDING PERMIT INFORMATION - 206 -431 -3670
Valuation of Project (contractor's bid price): VW xisting Building Valuation: $
Scope of Work (please provide detailed information): Q. 4-
2t
DID %M IAe .
Will there be new rack storage? ❑ Yes
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
'For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: V\
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTIONMAZARDOUS MATERIALS:
Is Sprinklers Bg Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 154 No
/f"yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q:1ApplicationsWonns- Applications On LineV •2006 - Permit Application.doc
Revised: 9 -2006
bh
i — No If yes, a separate permit and plan submittal will be required.
Compact:
Handicap:
Page 2 of 6
Date Application Accepted:
10
V 09—
I h � 1
Date Application Expires:
a l I� 1
Staff Initials:
f s :: i : _ ._.
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Print Name:
Mailing Address:
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
BUILDING
Signature: l I A N U�I,UI Ul l 1.
Date: /0 Z
(leM � / Day Telephone: 7/06 / I O g 1 b l 607. Q
1/_ l , u�t I �7 try �l) 1 I t( e lct W / 9. N
Q: Applications\Fortns- Applications On Line3-2006 - Permit Application.doc
Revised: 9 -2006
bh
Page 6 of 6
Parcel No.: 6364200010 Permit Number: D07 -397
Address: 2676 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 10/22/2007
Applicant: HOT TOPIC Issue Date:
Receipt No.: R08 -00912
City of Tukwila
Initials: WER Payment Date: 03/26/2008 01:11 PM
User ID: 1655 Balance: $0.00
Payee: TIMBERWOLFFCONSTRUCTION
doc: Receiot -06
Payment Check 2198 1,340.58
ACCOUNT ITEM LIST:
Description
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
TRANSACTION LIST:
Type Method Descriptio Amount
BUILDING - NONRES 000/322.100
STATE BUILDING SURCHARGE 000/386.904
RECEIPT
Account Code Current Pmts
Payment Amount: $1,340.58
1,336.08
4.50
Total: $1,340.58
0445: 03/26 8711 TOTAL.. 2054.34
Printed: 03 -26 -2008
Parcel No.: 2623049144
Address: 545 ANDOVER PK W TUKW
Suite No:
Applicant: COMPUPAY
Receipt No.: R07 -02166
Initials: JEM Payment Date: 10/03/2007 12:00 PM
User ID: 1165 Balance: $677.28
Payee: TAMARA K GENZALE
TRANSACTION LIST:
Type Method Description
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Permit Number: D07 - 379
Status: PENDING
Applied Date: 10/03/2007
Issue Date:
Payment Amount: $437.31
Amount
Payment Check 2295 437.31
Account Code Current Pmts
000/345.830 437.31
Total: $437.31
8 10/0 7iC TOTAL 437.71
doc: Receiot -06 Printed: 10 -03 -2007
Parcel No.: 2623049144 Permit Number: D07 -379
Address: 545 ANDOVER PK W TUKW Status: APPROVED
Suite No: Applied Date: 10/03/2007
Applicant: COMPUPAY Issue Date:
Receipt No.: R07 -02358 Payment Amount: $677.28
Initials: WER Payment Date: 10/30/2007 09:08 AM
User ID: 1655 Balance: $0.00
Payee: SOUTECENTER CORP
TRANSACTION LIST:
Type Method Description
Payment Check 1535 677.28
ACCOUNT ITEM LIST:
Description
BUILDING - NONRES
STATE BUILDING SURCHARGE
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Amount
Account Code Current Pmts
000/322.100 672.78
000/386.904 4.50
Total: $677.28
doc: Receiot -06 Printed: 10 -30 -2007
Project:
Cn s - 5, •v
Type of Inspection:
/Ica
).-,
v
Addre ` ,
!�' i 1
t-t/
Date Called:
-
Special Instructions: c
sttrru tions:
Date Wanted:
0
Requester:
Phone No
2—
— 92
— 2
INSPECTION RECORD
Retain a copy with permit
INSPE ION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION ?
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-
COMMENTS:
Approved per applicable codes. El Corrections required prior to approval.
Inspector: -� ; �� J Date: 1 ( /1( —( v
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
Project:
Type of Inspection:
Address: 5i.\.5 —
Suite #: ) 01
Contact Person:
L os\
Special Instructions:
Phone No.:
Needs Shift Inspection:
y e_s
Sprinklers:
Fire Alarm: rn.,,,,v PL_
Hood & Duct:
Monitor: P`„a
Lie
c -
Pre -Fire:
Permits:
Occupancy Type:
B
4
INSPECTION NUMBER
444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
PERMIT NUMBERS
Corrections required prior to approval.
COMMENTS:
Inspector: a
Date: \ \ \ Zia! b"1
Hrs.: '
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
Project: Co.., o P
Type of Inspection:
.in F2 L-' /5 ,t..viio &v
Address: 5 L/5 A P v✓
Suite #: Jo 1
Contact Person:
Z. ask,
Special Instructions:
Phone No.:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
3
CITY OF TUKWILA FIRE DEPARTMENT
INSPECTION NUMBER
ndover Park East, Tukwila, Wa. 98188 206 575 - 4407
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
- 379
o1 -s-
PERMIT NUMBERS
Corrections required prior to approval.
COMMENTS:
.1P2//Wk L E)2 -
fj - LT —
OS/EC -to 4 n h Z MA:. n
Inspector:
Date: //f7 0 l
Hrs.:
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
COMMENTS:
Type of Inspection:
/'� ;. i.,1/4„.„,
-� T�
Address: Sy S` 4A c14,,,c,.._ ,4, IL 4
Suite #:
Contact Person:
Chi", s
i"<< --
Special Instructions:
F:fl 14i Aad41
1 f51
,4 1 S S - r�iC----
/wTG : 4 rldfOe - R. 4tc,'
M "r
..57 -7`o
4sI4 /)
�v 5i -7 46, _
r oc,.
Project: G 0 „,, f ,,, r , y
Type of Inspection:
/'� ;. i.,1/4„.„,
-� T�
Address: Sy S` 4A c14,,,c,.._ ,4, IL 4
Suite #:
Contact Person:
Chi", s
i"<< --
Special Instructions:
Phone No.:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
INSPECTION NUMBER
444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
1)07- 371
a?- s - Z S�
PERMIT NUMBERS
r7 Corrections required prior to approval.
Inspector: 5C j L jc
Date: /OW
Hrs.:
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
Project:
(;) 3 »2 ?/ A-9
J
Type of Inspection:
` 175/7GAjd '
Address:
..5 4/5 /- .ulw (' lL.--
Date Called:
Special Instructions:
q: /
Date ante a.m.
/ .) L /
U
Requester:
Phone No:
206 -276
— 73 7 j
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION '
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3E7
pproved per applicable codes. El Corrections required prior to approval.
COMMENTS:
El $58.00 REINSP ` ION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
(Receipt No.:
'Date:
INSPECTION RECORD
Retain a copy with permit
Projec:
Type of Inspection:
[�
Address: _ // !!! / / / �/ /
�Y 5 / 1 A &V'/ /.
Date Called:
Special Instructions:
Date Wanted:
(a.z
Requester:
Phone No:
A,2
/
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206)431 -3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
i
f Ins Pecto Date:
$58.00 REII PECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
Project:
Type of Ins ection:-
.,.r.—...i-eIZ f mi<
Address:
-5 ( /"),/cf cvev P4 (}
Date Called:
Special Instructions:
Date Wanted:
/ 0 /?
/ /C-2 /11Z
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
DO7-57c
42 Approved per applicable codes. Corrections required prior to approval.
$58.00 REINS CTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
'Receipt No.:
1Date:
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 )431 -
COMMENTS:
'Inspector:
Date:
./.."--.?/-0`7
ACTIVITY NUMBER: D07 -379 DATE: 10 -03 -07
PROJECT NAME: COMPUPAY
SITE ADDRESS: 545 ANDOVER PK W
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Buildin Division
P I'c Wor C
- a1
Comments:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28-02
�.r PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Approved with Conditions
till Attic Io'I4'a
Fire Prevention iAj
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Ni Incomplete n
rya. Ia c�.'o
P nning Division
Permit Coordinator ❑
DUE DATE: 10-04-07
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUT NG:
Please Route Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
DATE:
DUE DATE: 1 1-01-07
Not Approved (attach comments) F ,
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License
DPINCGC066BU
Licensee Name
D P INC GENERAL CONTRACTORS
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601515833 Verify Workers Comp Premium
Status
Ind. Ins. Account
Id
Business Type
CORPORATION
Address 1
19909 BALLINGER WAY NE
! Address 2
City
SEATTLE
County
KING
State
WA
Zip
98155
Phone
2063612989
{ Status
ACTIVE
Specialty 1
GENERAL
ti Specialty 2
UNUSED
Effective Date
1/31/1994
Expiration Date
1/31/2008
Suspend Date
Separation Date
Parent Company
Previous License
DODSOPI101JB
Next License
Associated
License
Look Up a Contractor, Electrician or Plumber License Detail
or ,.. nust>�es
Search I
Home Safety Claims & Insurance - Workplace Rights Trades & Licensing
Find a Law or Rule Get a Form or Publication
Up a Contractor, Electrician or Plumber
Printer Friendly Version
General /Specialty Contractor
IA business registered as a construction contractor with LStI to perform construction work within the scope
of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment
of account and carry general liability insurance.
License Information
Topic Index I Contact Info
Page 1 of 3
https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= DPINCGC066BU 10/30/2007
•
ACT ACOUSTICAL CEILING TILE LL @TE BY LANDLORD AT TENANTS EXPENSE
ADJ ADJACENT /ADJUSTABLE LF LINEAL FOOT
AFF ABOVE FINISH FLOOR MAX MAXIMUM
ALT ALTERNATE MECH MECHANICAL
ALUM ALUMINUM MFR MANUFACTURER
APPROX APPROXIMATELY MIN MINIMUM
AT
@ MISC MISCELLANEOUS
BLDG BUILDING MTD MOUNTED
BLKG BLOCKING MTL METAL
B/S BUILDING STANDARD MW MICROWAVE OVEN
CAB CABINET N NORTH, NEW
CLR CLEAR/CLEARANCE N/A NOT APPLICABLE
CLG CEILING NIC NOT IN CONTRACT
CL CENTERLINE NO NUMBER
COL COLUMN NOM NOMINAL
COMM COMMUNICATION NTS NOT TO SCALE
COMP COMPOSITION OC ON CENTER
CONST CONSTRUCTION OPNG OPENING
CONT CONTINUOUS OPP OPPOSITE
CPT CARPET ORIG ORIGINAL
CT CERAMIC OR CONCRETE TILE PERM PERMANENT
DIA DIAMETER PL PLATE
DIM DIMENSION PLAM PLASTIC LAMINATE
DR DOOR PLYWD PLYWOOD
DW DISHWASHER PR PAIR
DWG DRAWING PTR PARTITION
E EXISTING, EAST R RADIUS, REMOVE, RELOCATE
EA EACH RB RUBBER BASE
ELEC ELECTRIC REF REFRIGERATOR
ELEC'L ELECTRICAL REINF REINFORCING
ELEV ELEVATION (VIEW) REQ'D REQUIRED
EXIST EXISTING REV REVISION/REVERSE
EXT EXTERIOR RM ROOM
FIN FINISH RO ROUGH OPENING
FLR FLOOR s SOUTH
SCHED SCHEDULE
FLUOR FLUORESCENT
FR FIRE RATED SC SOLID CORE
SECT SECTION
FT FEET
FURN FURNISH/FURNISHINGS SIM SIMILAR
FU GAUGE SPEC SPECIFICATION
GA
GALV GALVANIZED SQ SQUARE
STD STANDA D
GD GARBAGE DISPOSAL
GL GLASS /GLAZING STL STEEL:
STOR STORAGE GWB GYPSUM WALL BOARD
HC HOLLOW CORE SUSP SUSPENDED
HDW HARDWARE TEL TELEPHONE
HM HOLLOW METAL TYP TYPICAL
HT HEIGHT UNO UNLES NOTED OTHERWISE
HVAC HEATING, VENTILATING, VCT VINYL COMPOSITION TILE
AIR CONDITIONING VERT VERTICAL
IN INCH W WEST
INCL INCLUDE W/O WITHOUT
INSUL INSULATION
INT INTERIOR WC WALLCOVERING
WD WOOD
JT JOINT
WSBF WASHINGTON STATE BARRIER FREE
SEISMIC BRACING 9/TI 1.
4
SOUTHCENTER
CORPORATE S
BUILIDING 1
5 45 ANDOVER PARK WEST
TUKWILA WASHINGTON 98188
REGISTERED ,
�R�
ARCHITECT
1. O 11 I? �O N
�3,�'t"st°SyiL'eF!
_ . - - - •
\kda
S
i
r
a
¢
a_
1-
_______I
STRAN I
.
T•
ER BLVD.
a D
2
BLDG 1
a 5
PROVIDE AT DEMISING AND PER
SOUND PARTITIONS 4' -0" WIDE
ACOUSTICAL CEILING TILES
CENTERED OVER PARTITION
�� °
D
l
2
ABOVE HUNG CEILING. 1/4 NON COMB. W❑ FILLER
UNDER MAIN RUNNERS
CONTINUOUS CEILING GRID
ce
w
0
z
-
E I
I SSOS <I<I NIII<S1<fUSS•A DO NOT CUT.
lIII ssF'
4
Ill
r
¢
ec
U
o
Z
► ) . 1Vd .�AOQNV
r
'I�
F___4.....°
/ LINE OF CEILING GRID BEYOND, SEE
R.C.P.
CONT. '12 METAL TRIM WI PAPER WING
REVEAL (PAINT BLACK) OR MATCH
EXISTING CONDITION.
�,
i�
;:
-
�,
<
�
8
MINK
R E
S
LVD.
T E
1/8" BLACK FOAM TAPE HOLD BACK 1/4" /
CONT. 31/2" 1 1/4" 25 GA. TRACK WI (2)
9
7
6
x
#10 SCREWS @ 24" O.C.
HEAD SECTION
t,
FROM EDGE OF TRACK
UPLAND D'.
co MIDLAND D'.
o
\_.
TRILAND D • .
K }
MINKLER BLVD. NORTH
NORTH
�'
1
VICINITY MAP NTS
SITE PLAN NTS
PROVIDE ACOUSTIC aATT
INSULATION BETWEEN STUDS
AT SOUND AND DEMISING
PARTITIONS, ONLY.
I
��
= �r
31/2" x 25 GA. GALV. STEEL STUD @ 24"
4 O.C. WITH 518" TYPE x GWB EACH SIDE.
PLAN VIEW
co
SCOPE OF WORK
ii 1 0 s n (�
OCCUPANT LOAD:
' .'
6,583 SF @ 1:100 = 66 OCCUPANTS
2 EXITS REQUIRED, 3 EXITS PROVIDED
n (l (1
T
(1
PARTIAL FLOOR TENANT IMPROVEMENT ON THE FIRST FLOOR OF AN EXISTING OFFICE SPACE WHICH IS
APPROXIMATELY ±6,583 U.S.F. THE WORK CONSISTS OF DEMOLITION AND CONSTRUCTION OF PARTITIONS,
AND OTHER FEATURES THERE IS NO STRUCTURAL OR GORE AND SHELL WORK
�[ F CC► �
CONSTRUCTION TYPE: TYPE V -B ' R �^ " ° �� AN 1- -
LON EST DI GONAL `1' 7
T
i
iDOORS
i
:
.
1,
�
5/8" GWB, TYPE '7C EACH SIDE, TYP.
f 1 i i I
- `. •- =
//
pi
44
p
/
j
' ,
, P
• ;
am--4
BASE AS SCHEDULED.
_
_
11
i %1
� ® E CO
SPRINKLERS: SPRINKLERED � ��'� '
m °°
I��e�
a-
......... >:
,_� f
��
°m
° °
■ _
��
i
n
�•
�:
��
, 4 ,
'���I
OCCUPANCY: B - OFFICE C� < /1 7 4
b �
r
::'.: .. l
r
CONT. 25 G A GALV. STEEL RUNNER
CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER
3/4" MIN. EMBEDMENT.
BASE SECTION
'
% I
/
AREA OF WORK: ±6,583 5F
-
_6: = =a
Marvin Ste , ■ soc�ates, LLC
planning design
p g g
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
n EXIT .`
'�/,
Jr- /
��
720
of vo olia
ARCEL ID: 51- 0599163 �� S O o,
y., '
/`r4 i
6�'�
B IL®�C � ..`F
LEGAL DESCRIPTION
M1 f���»�
--
ALL THAT CERTAIN REAL PROPERTY SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING STATE OF
WASHINGTON, BEING A PORTION OF THE EAST 1/2 OF THE NORTHWEST 1/4 OF THE SOUTHEAST 1/4 OF SEC.
26 T R W AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINING AT THE
INTERSECTION OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4 WITH THE WESTERLY MARGIN OF
ANDO VER PARK WEST (59TH AVENUE SOUTH), DISTANT ALONG SAID NORTHERLY LINE N88 °05'42"W 1369.34
FEET FROM THE NORTHWEST CORNER OF SAID SOUTH- EAST QUARTER; THENCE FROM SAID POINT OF
BEGINNING ALOND SAID WESTERLY MARGIN S01 °47'29" V1/ 451.30 FEET; THENCE LEAVING SAID WESTERLY
MARGIN TANGENT TO THE PRECEDING COURSE ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A
RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 90 °6'49 ", AN ARC LENGTH OF 78.64 FEET TO A POINT ON A
LINE THAT IS PARALLEL TO AND 501.40 SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4;
THENCE ALONG SAID PARALLEL LINE N88 °05'42 "W 180.90 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH
AND 261.00 FEET WESTERLY OF THE EAST LINE IF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE
N01 °47'29 "E 136.00 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 365.40 FEET SOUTHERLY OF THE
NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE S88 °05'42 "E 37.50 FEET
TO A POINT ON A LINE THAT IS PARALLEL TO AND 223.50 FEET WESTERLY OF THE EAST LINE OF SAID EAST
1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 100.00 FEET TO A POINT ON A LINE THAT IS
PARALLEL TO AND 265.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE
ALONG LAST SAID PARALLEL LINE N88 °05'42 "W 12.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND
236.00 FEET WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE
N01 °47'29 "E 265.40 FEET TO A POINT ON THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID
NORTHERLY LINE 588 °05'42 "E 206.00 FEET TO THE POINT OF BEGINNING AND CONTAINING 2.408 ACRES OF
LAND MORE OR LESS.
APPLICABLE CODES:
,.
, 41 •
w ����
/
' prep,
/
A
�
, ► � , �r
�/ ; a � I�
= ^
' ���� EXIT
-
%��i
;�
..,�
�
i/�
( �
EXIT'�
�q
5
EXITS SEPARATION
NORTH
DRAWN BY: TN, AP JOB NO.: 99135.050
` 3
ABBREVIATIONS
4
B/S TENANT PARTITION NTS
5
EXI T I
N KEY PLAN U PANT LOAD AL . NTS
PERMIT SET
CHECKED BY: SN DATE: 08/27/07
#10 SCREWS \
METAL STUDS STAGGERED 8' 0 "
CONTRACTOR SHALL PROVIDE ALL WORK AND MATERIALS IN ACCORDANCE WITH APPLICABLE CITY, COUNTY, STATE AND
FEDERAL BUILDING AND FIRE CODES.
CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN THE CONTRACT DRAWINGS &SPECIFICATIONS.
CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY
DISCREPANCIES BEFORE PROCEEDING WITH WORK.
CONTRACTOR SHALL OBTAIN ALL PERMITS AND APPROVALS.
B/S INDICATES "BUILDING STANDARD" A5 PROVIDED BY LANDLORD AS DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT
DOCUMENTS. IF NOT SPECIFIED, CONTRACTOR SHALL SEE ADJACENT SPACES FOR EXISTING EXAMPLES AND CONDITIONS.
WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS.
ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE ALARM AND SPRINKLER AND SECURITY DESIGN SHALL BE PERFORMED BY
THE CONTRACTOR
ALL FURNITURE DESIGN SHOWN ON PLANS IS SCHEMATIC ONLY AND NOT IN CONTRACT, UNO. TENANTS FURNITURE
VENDOR SHALL FIELD VERIFY PREMISE FOR LAYOUT CONFIGURATION AND CLEARANCES.
ALL VOICE /DATA AND CABLING DESIGN SHOWN ON PLANS IS SCHEMATIC ONLY AND NOT IN CONTRACT, UNO. TENANTS
CABLING VENDOR SHALL VERIFY TENANTS REQUIREMENTS AND FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE
ROUGH -IN AS NOTED, COORDINATION AND SCHEDULING FOR THIS PORTION OF THE WORK.
THE FOLLOWING DRAWINGS ARE BASED ON ELECTRONIC INFORMATION DERIVED FROM A NUMBER OF SOURCES. WHILE
DEEMED RELIABLE, MS&A CANNOT BE HELD RESPONSIBLE FOR INFORMATION FROM OTHERS NOT FIELD VERIFIED OR WHICH
HAS BEEN ALTERED BY OTHERS.
THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING MANAGEMENT ON CONSTRUCTION HOURS, PROCEDURES AND
METHODS ALLOWABLE IN THIS BUILDING.
THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF VV. V. BOXES. IF LIGHTING LAYOUT CREATES
A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE
REQUIRED.
CONTRACTOR TO UPGRADE SIESMIC BRACING AS REQUIRED AT EXISTING CEILING.
CONTRACTOR TO FIELD VERIFY ALL ELEMENTS INDICATED AS EXISTING ON PLANS.
DOORS & HARDWARE SHALL BE REUSED, RELOCATED OR NEW BASED ON AVAILABLITY AND SUITABLITY.
ALL HARDWARE SHALL BE TENANT STANDARD FINISH. MATCH EXISTING CONDITIONS.
1
I`
I
P
iI
■
� .,
VERTICAL WIRE HANGER-NO. 12 GAUGE @4'-0"
O.. .10 GAUGE @ -0" O.C. ALONG EACH
C OR NO 5'
MAIN RUNNER
P
HEAVY GAUGE WIRE "PIN ".
SCALE: AS NOTED
@
O.C. FOR ALL UNBRACED STRAIGHT
RUNS OF WALL OVER 12'-0 ".
ATTACH TO STRUCTURE ABOVE W/
HILTI POWER DRIVEN FASTENER
3/4" MIN.
CONTINUOUS CEILING GRID - DO
REVISIONS /ISSUANCE:
NO.
REVISIONS INDICATED THUS / `
A
DATE
FASTENED TO MAIN RUNNER AND CUT TIGHT TO
STRUT @ 12' -0" EACH DIRECTION STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL
WIRE HANGER AND HEAVY GAUGE WIRE PIN.
INTERNATIONAL BUILDING CODE, 2006 EDITION, AS ADOPTED BY THE STATE OF WASHINGTON.
IN ICC TERNATIONAL A117.1, 2003 FIRE EDITION. CODE, 2006 EDITION, AS ADOPTED BY THE STATE OF WASHINGTON.
WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11
WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (WSVIAQ)
°
PROJECT DIRECTORY "
PERMIT SET
8/27/07
CONSTRUCTION SET
10/01 /07
(2)
NOT CUT.
"
REVISION SET
10/02/07
45°
�1
! -4
5° HEAVY DUTY MAIN RUNNER AT 4' -0" O.C.
� 45°
««««��««<,�unk.WI
«««<ti«it
REVEAL (PAINT BLACK) OR
_„
SUSPENDED CEILING.
1,�
J
`"
"
wi VERTICAL STRUT FASTENED TO MAIN RUNNER
`
r =
3 1/2" X 25 GA. STL. STUDS 24"
- CROSS RUNNER
INSTALLATION:
BUILDING REPRESENTATIVE: PROPERTY MANAGER:
MATCH EXISTING.
1/8° BLACK FOAM TAPE
HOLD BACK 1/4" FROM
EDGE OF TRACK.
�� )
a;
=E
•`
,,: G---
@
O.C. W/ 5/8" GWB, TYPE 'X', EACH
SIDE.
-
:k
r
s
MERIWETHER PARTNERS LLC PINNACLE REALTY MANAGEMENT CO.
2ND & SENECA BUILDING 810 3RD AVE.
1191 2ND AVE. SUITE 140
SUITE 1570 SEATTLE, WA 98104
SEATTLE, WA (206) 903 -0662 (P)
(206) 816 -1570 (P) (206) 903 -0668 (FAX)
(206) 381 1200 (FAX) CONTACT: TAMARA GENZALE
CONTACT: JOEL P. ASLANIAN EMAIL: tgenzale @pmic.com
EMAIL: jaslanian @mericap.com
SPACE PLANNER TENANT:
j
INSTALL PER INTERNATIONAL BUILDING CODE SECTION 803.9.1.1. AND 1621.1 "SUSPENDED ACOUSTICAL CEILINGS" AND ASCE 7 -02.
SUSPENDED CEILING SUPPORT DATA:
LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR
DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS
RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF
THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE
FIRST POINT WITHIN 4' -0" FROM EACH WALL.
PROVIDE LATERAL BRACING AT ALL CEILING AREAS GREATER THEN 144 SF SURROUNDED BY WALLS THAT
CONNECT DIRECTLY TO STRUCTURE ABOVE.
VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND
SADDLE -TIED AROUND MAIN RUNNERS, PER 2003 IBC SECTION 803.9.1.1. CROSS RUNNERS ATTACHED TO
MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED
EQUIVALENT, PER 2003 IBC SECTION 803.9.1.1. DISCONTINUOUS ENDS OF CROSS - RUNNERS AND MAIN
RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE
CEILING IS INTERRUPTED BY A WALL.
CEILINGS OVER 2500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HT PTNS THAT BREAKS THE
CEILING UP INTO AREAS NOT EXCEEDING 2500 SF.
FOR CEILINGS W/O RIGID BRACING, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 IN.
OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT
LEAST 1 IN IN ALL HORIZONTAL DIRECTIONS; OR, SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT
THAT CAN ACCOMMODATE 1 IN OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS.
CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING.
CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING.
CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO DETAILS
SHOWN.
NOTES:
MARVIN STEIN AND ASSOCIATES, LLC COMPUPAY, INC.
2221 5TH AVE. 2302 MARTIN STREET, SUITE 300
SEATTLE, WASHINGTON 98121 IRVINE, CA 92612
CONTACT: LISA BOLSTER CONTACT: LISA CARMEN
TEL: (206)441 -1449 TEL: (949) 885 -8100 x1205
FAX: (206) 441 -4361 EMAIL: lisacarmen @compupay.com
EMAIL: (.bolster @marvinstein.com
LATERAL BRACING TENANT WALLS (NO CASEWORK)
TENANT:
COMPUPAY RECEIVED
�
� OF TUKWILA
OCT ; ..- 3 2007
F ,
ER` "' (` '` I e.n
B' MAX B' MAX B' MAX B' MAX B' MAX 8' MAX MAX 2'
1 if
I
I
I I
\
-
\
PER
6
plan
VIOIN�I
O f
GENERAL NOTES
l
PROJECT INFORMATION /DIRECTORY
ALABO E(n)
NOTES:
S EPA - P N
REQUI
� �
review � � � u E
not euthceize
or wawa �' " Gas PIPing
� �le ed C- of Tukwita
/ ' BUILDING orvrsroN
TI -1 COVER SHEET & DETAILS.
TI -2 DEMOLITION PLAN
TI-3 CONSTRUCTION PLAN
TI -4 REFLECTED CEILING PLAN
TI -5 ELEVATIONS AND SECTIONS
TI-6 ELECTRICAL/ COMMUNICATIONS PLAN
SHEET TITLE:
FIRST FLOOR
COVER S H E ET & DETAILS
W....... �
1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH
WALLS AT LEAST 4 FT. LONG.
(PER TYP. PART. PLAN)
2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL
UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE
DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY.:
3. PROVIDE BRACING AT ANY PERMANENTLY PARTITION THAT IS NOT ATTACHED TO CEILING GRID.
it qI �0 D _
1. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRENT
CODES AS NECESSARY.
2. POWER DRIVEN FASTENERS SHALL NOT BE USED FOR TENSION LOADS APPLICATIONS.
3. THE GRID SHALL BE ATTACHED AT TWO ADJACENT WALLS.
City of Tukwila __REVISIONS
BUILDING N o chances shall b ma to the scope
BUILDING DIVISION of work wit hout prior appr oval of
T Building DiviS On•
NOTE: Revisions will require a new plan submittal
and may include additional plan .—_ # _ ,
REPRODUCTION, ALTERATION OR PUBLICATION OF THIS
DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A
MS &A TIONO OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY
I�
I _ I
S
SUSPENDED CEILING SUPPORT DATA NA
9
PARTITION HEAD BRACING DETAIL NTS
14
NA
11
DRAWING INDEX
OF 6
,r
SOUTHCENTER
CORPORATE
BUILDING
545 ANDOVER
TUKWILA,
WASHINGTON
•-•., - -
'TE OF
SQUARE
I
PARK WEST
98188
REGISTERED
ARCHITECT '
P DONAHOU
WASHINGTON
.
Marvin Ste 1 .sociates, tic
planning design
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441-1449
DRAWN BY: TN, AP JOB NO.: 99135.050
PERMIT SET
CHECKED BY: SN DATE: 08/27/07
SCALE: AS NOTED .
REVISIONS/ISSUANCE:
NO.
REVISIONS INDICATED THUS
DATE
PERMIT SET
8/27/07
CONSTRUCTION SET
10/01 /07
,
c
a
-ct
=
c
v
L.
i_
..:1
a
c
a
a
C
a
TENANT:
COMPUPAY4747411.4
OCT !-3 2007
CENTEF
SHEET TITLE:
FIRST FLOOR
DEMOLITION PLAN
.
REPRODUCTION, ALTERATION OR PUBLICATION OF THIS
DRAWING, WITHOUT EXPRESS PERMISSION BY MS&A, IS A
VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY
MS&A 2007.
1-
OF 6
—
L L_'
FIRST FLOOR PLAN
SCALE: 1/8"
7-7
LL-
DEMOLITION GENERAL NOTE:
1. REFER TO THE CONSTRUCTION PLAN FOR DIMENSIONS OR EXTENT OF
DEMOLITION.
n
I
NORTH
0 5' 10' 20' 30'
I
DEMOLITION KEYNOTES:
0 REMOVE EXISTING CORK BOARD. VERIFY WITH TENANT.
0 EXISTING CASEWORK TO REMAIN
REVIEWED FOR
CODE COMPLIPMC'E.
APPROVe
MI 2
City Of Tukwila \
'WING DIVISICV
II
NOT IN CONTRACT
BREAK
1117H
110 I A I b
I I I .._J L--- -�-_ ---J L
101 I A
OFFICE
1031
l Ams
1
OFFICE
OPEN
WORK
AREA
s 116 I
AREA
MULJ
PTN.
L --
OPEN
WORK
AREA
X1051
mid
L
I I I•. I I 1
L_ - - _L OPEN L--- _- ---J WORK
--- - - - -� �- - --
I - - �T. + - - -
J-- -
co
SCALE: 1/8" =1' -0"
MUL./
PTN.
1 108
r
FILES
OFFICE
WORK
AREA
HI 109
FIRST FLOOR PLAN
NORTH
0 5' 10' 20' 30'
I
OFFICE
H1 114
Q EXISTING 60- MINUTE RATED CORRIDOR.
O2 EXISTING DEMISING PARTITION TO REMAIN.
O 3 EXISTING CASEWORK TO REMAIN.
0 REMOVE EXISTING LIGHT SWITCH. SEE RELATED CEILING KEYNOTE. PATCH AND
FINISH TO MATCH ADJACENT.
0 5 EXISTING RELITE TO REMAIN.
Q 6 CONTRACTOR TO PROVIDE AND INSTALL B/S ADJUSTABLE SHELVES (2) HIGH
STARTING AT 68" A.F.F. ON HEAVY DUTY STANDARDS AND BRACKETS.
C 7 CONTRACTOR TO CONSIDER THREE (3) PEOPLE AND AT LEAST TEN (10) PRINTERS
WHEN RE- BALANCING HVAC.
Q 8 CONTRACTOR TO CONSIDER SERVER EQUIPMENT WHEN RE- BALANCING HVAC.
COORDINATE WITH TENANT.
a 9 RECOVER CASEWORK WITH NEW LAMINATE.
10 CONTRACTOR IS TO PROVIDE AND INSTALL VCT TILE FLOORING IN ROOMS
INDICATED. COORDINATE WITH LANDLORD/TENANT.
OPEN
WORK
AREA
31
OFFICE
1
112 1
COURIER
PICK -UP
AREA
STORAGE
110
GENERAL CONSTRUCTION NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY DEMOLITION REQUIRED TO
COMPLETE THE WORK AS DESCRIBED ON THE CONSTRUCTION DOCUMENTS.
2. CONTRACTOR SHALL PROTECT ALL EXISTING FINISHES AND ASSEMBLIES NOT BEING
REMOVED OR ALTERED DURING CONSTRUCTION.
3. CONTRACTOR SHALL PROVIDE NEW FRAMING AND FINISHES THAT ARE FLUSH,
CONSISTENT AND IN ALIGNMENT WITH EXISTING CONDITIONS. IN THE EVENT OF FRAMING
SIZE DIFFERENCES, THE CONTRACTOR SHALL FURR OR ADJUST THE FRAMING AS
REQUIRED FOR PROPER ALIGNMENT.
4. CONTRACTOR SHALL VERIFY MINIMUM FRAMING SIZE REQUIRED FOR ELECTRICAL,
MECHANICAL AND PLUMBING FEATURES BEING INSTALLED BY DESIGN/BUILD AND ADJUST
THE FRAMING ACCORDINGLY.
5. CONTRACTOR SHALL PATCH TO MATCH AND PREPARE FOR FINISH AT ALL LOCATIONS
WHERE EXISTING ASSEMBLIES ARE ADJACENT TO DEMOLISHED OR ALTERED ASSEMBLIES.
6. THE SCOPE OF WORK SHALL INCLUDE BOTH SIDES OF ALL NEW ASSEMBLIES DEPICTED
ON THE DRAWINGS EVEN WHEN LOCATED IN AN ADJACENT LEASE SPACE. NO PART OF
THE WORK IS TO BE LEFT UNFINISHED U.N.O.
7. CHANGES TO SPECIFICATIONS CAN BE MADE IF APPROVED BY MS&A, THE BUILDING
MANAGEMENT AND THE TENANT.
8. CONTRACTOR SHALL SUPPLY ALL REQUIRED JUNCTION BOXES, COVERS AND ACCESS
DOORS AS NECESSARY. VERIFY BUILDING STANDARDS.
9. CONTRACTOR SHALL CONFIRM TYPE AND LOCATION OF FIRE EXTINGUISHERS AND /OR
CABINETS WITH THE GOVERNING FIRE MARSHAL BEFORE INSTALLATION. IF NOT
SPECIFIED ON DRAWINGS, CONTRACTOR SHALL PROVIDE THE MINIMUM NUMBER OF WALL
MOUNTED FIRE EXTINGUISHERS REQUIRED BY CODE. VERIFY WITH BUILDING
MANAGEMENT.
DOOR SCHEDULE:
6" UNLESS
OTHERWISE HARDWARE
NOTED a. B/S LATCHSET.
b. B/5 LOCKSET.
B/S DOUBLE DOOR CLOSET HARDWARE.
DOOR NOTES:
DOOR NUMBER
TYPE OF DOOR
A. NEW B/S 3' -0" WIDE x FULL HEIGHT HIGH S.C. WOOD DOOR IN B/S
WOOD FRAME.
B. PAIR OF NEW B/S 3' -0" WIDE x FULL HEIGHT HIGH S.C. WOOD
BI -FOLD CLOSET DOOR IN B/S WOOD FRAME.
EXISTING DOOR TO REMAIN.
1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. ALL
HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER
OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP
WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF
THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND
48" MAX. ABOVE THE FLOOR
2. RE -USE EXISTING DOORS SCHEDULED FOR REMOVAL WHEREVER POSSIBLE. DOORS
TO BE RE -USED ARE TO BE TOUCHED UP TO BRING INTO "LIKE NEW" CONDITION.
3. THRESHOLDS AT DOORWAYS SHALL BE 1/2' MAXIMUM IN HEIGHT.
4. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER DONE
FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N),
SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE
FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD
THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE
ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. PROVIDE WALL STOPS
(FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS.
CONSTRUCTION KEY NOTES: CONSTRUCTION LEGEND:
= =T
. NEW, UNO, B/S TEMPERED SAFETY GLASS RELITE.
NEW B/S CORRIDOR PARTITION TO MATCH EXISTING.
CARDREADER
EXISTING B/S 1 -HR. CORRIDOR PARTITION TO REMAIN.
CODE C( n et rop
App c a A 20
S ICM
at VII DIt D
EXISTING B/S CONSTRUCTION TO REMAIN.
EXISTING B/S DEMISING PARTITION.
EXISTING CONSTRUCTION TO BE DEMOLISHED.
NEW B/S TENANT INTERIOR PARTITION: 31/2" METAL STUDS WITH 5/8" TYPE'X' GWB EACH
SIDE FROM FLOOR TO UNDERSIDE OF HUNG CEILING. SEE DETAIL 4/TI -1.
SOUTHCENTER
CORPORATE SQUARE
BUILDING
545 ANDOVER PARK
TUKWILA, WASHINGTON
REGISTERED
ARCHITECT
I L P H
I
WEST
98188
P. CiOR4.RHOU
t OF WASHINGTON
Marvin Ste ::sociates, LLc
tannin design
g n g
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
DRAWN BY: TN, AP JOB NO.: 99135.050
PERMIT SET
CHECKED BY: SN DATE: 08/27/07
SCALE: AS NOTED
REVISIONS /ISSUANCE:
NO.
REVISIONS INDICATED THUS n
DATE
PERMIT SET
8/27/07
CONSTRUCTION SET
10/01/07
c
u_
Q
a
L,
:1
TENANT:
COMPUPAY C RECEIVED
OCT 1- 3 20071
SHEET TITLE:
FIRST FLOOR
CONSTRUCTION PLAN
REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2007.
OF 6
—
NOT IN CONTRACT
BREAK
1117H
110 I A I b
I I I .._J L--- -�-_ ---J L
101 I A
OFFICE
1031
l Ams
1
OFFICE
OPEN
WORK
AREA
s 116 I
AREA
MULJ
PTN.
L --
OPEN
WORK
AREA
X1051
mid
L
I I I•. I I 1
L_ - - _L OPEN L--- _- ---J WORK
--- - - - -� �- - --
I - - �T. + - - -
J-- -
co
SCALE: 1/8" =1' -0"
MUL./
PTN.
1 108
r
FILES
OFFICE
WORK
AREA
HI 109
FIRST FLOOR PLAN
NORTH
0 5' 10' 20' 30'
I
OFFICE
H1 114
Q EXISTING 60- MINUTE RATED CORRIDOR.
O2 EXISTING DEMISING PARTITION TO REMAIN.
O 3 EXISTING CASEWORK TO REMAIN.
0 REMOVE EXISTING LIGHT SWITCH. SEE RELATED CEILING KEYNOTE. PATCH AND
FINISH TO MATCH ADJACENT.
0 5 EXISTING RELITE TO REMAIN.
Q 6 CONTRACTOR TO PROVIDE AND INSTALL B/S ADJUSTABLE SHELVES (2) HIGH
STARTING AT 68" A.F.F. ON HEAVY DUTY STANDARDS AND BRACKETS.
C 7 CONTRACTOR TO CONSIDER THREE (3) PEOPLE AND AT LEAST TEN (10) PRINTERS
WHEN RE- BALANCING HVAC.
Q 8 CONTRACTOR TO CONSIDER SERVER EQUIPMENT WHEN RE- BALANCING HVAC.
COORDINATE WITH TENANT.
a 9 RECOVER CASEWORK WITH NEW LAMINATE.
10 CONTRACTOR IS TO PROVIDE AND INSTALL VCT TILE FLOORING IN ROOMS
INDICATED. COORDINATE WITH LANDLORD/TENANT.
OPEN
WORK
AREA
31
OFFICE
1
112 1
COURIER
PICK -UP
AREA
STORAGE
110
GENERAL CONSTRUCTION NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY DEMOLITION REQUIRED TO
COMPLETE THE WORK AS DESCRIBED ON THE CONSTRUCTION DOCUMENTS.
2. CONTRACTOR SHALL PROTECT ALL EXISTING FINISHES AND ASSEMBLIES NOT BEING
REMOVED OR ALTERED DURING CONSTRUCTION.
3. CONTRACTOR SHALL PROVIDE NEW FRAMING AND FINISHES THAT ARE FLUSH,
CONSISTENT AND IN ALIGNMENT WITH EXISTING CONDITIONS. IN THE EVENT OF FRAMING
SIZE DIFFERENCES, THE CONTRACTOR SHALL FURR OR ADJUST THE FRAMING AS
REQUIRED FOR PROPER ALIGNMENT.
4. CONTRACTOR SHALL VERIFY MINIMUM FRAMING SIZE REQUIRED FOR ELECTRICAL,
MECHANICAL AND PLUMBING FEATURES BEING INSTALLED BY DESIGN/BUILD AND ADJUST
THE FRAMING ACCORDINGLY.
5. CONTRACTOR SHALL PATCH TO MATCH AND PREPARE FOR FINISH AT ALL LOCATIONS
WHERE EXISTING ASSEMBLIES ARE ADJACENT TO DEMOLISHED OR ALTERED ASSEMBLIES.
6. THE SCOPE OF WORK SHALL INCLUDE BOTH SIDES OF ALL NEW ASSEMBLIES DEPICTED
ON THE DRAWINGS EVEN WHEN LOCATED IN AN ADJACENT LEASE SPACE. NO PART OF
THE WORK IS TO BE LEFT UNFINISHED U.N.O.
7. CHANGES TO SPECIFICATIONS CAN BE MADE IF APPROVED BY MS&A, THE BUILDING
MANAGEMENT AND THE TENANT.
8. CONTRACTOR SHALL SUPPLY ALL REQUIRED JUNCTION BOXES, COVERS AND ACCESS
DOORS AS NECESSARY. VERIFY BUILDING STANDARDS.
9. CONTRACTOR SHALL CONFIRM TYPE AND LOCATION OF FIRE EXTINGUISHERS AND /OR
CABINETS WITH THE GOVERNING FIRE MARSHAL BEFORE INSTALLATION. IF NOT
SPECIFIED ON DRAWINGS, CONTRACTOR SHALL PROVIDE THE MINIMUM NUMBER OF WALL
MOUNTED FIRE EXTINGUISHERS REQUIRED BY CODE. VERIFY WITH BUILDING
MANAGEMENT.
DOOR SCHEDULE:
6" UNLESS
OTHERWISE HARDWARE
NOTED a. B/S LATCHSET.
b. B/5 LOCKSET.
B/S DOUBLE DOOR CLOSET HARDWARE.
DOOR NOTES:
DOOR NUMBER
TYPE OF DOOR
A. NEW B/S 3' -0" WIDE x FULL HEIGHT HIGH S.C. WOOD DOOR IN B/S
WOOD FRAME.
B. PAIR OF NEW B/S 3' -0" WIDE x FULL HEIGHT HIGH S.C. WOOD
BI -FOLD CLOSET DOOR IN B/S WOOD FRAME.
EXISTING DOOR TO REMAIN.
1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. ALL
HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER
OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP
WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF
THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND
48" MAX. ABOVE THE FLOOR
2. RE -USE EXISTING DOORS SCHEDULED FOR REMOVAL WHEREVER POSSIBLE. DOORS
TO BE RE -USED ARE TO BE TOUCHED UP TO BRING INTO "LIKE NEW" CONDITION.
3. THRESHOLDS AT DOORWAYS SHALL BE 1/2' MAXIMUM IN HEIGHT.
4. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER DONE
FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N),
SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE
FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD
THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE
ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. PROVIDE WALL STOPS
(FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS.
CONSTRUCTION KEY NOTES: CONSTRUCTION LEGEND:
= =T
. NEW, UNO, B/S TEMPERED SAFETY GLASS RELITE.
NEW B/S CORRIDOR PARTITION TO MATCH EXISTING.
CARDREADER
EXISTING B/S 1 -HR. CORRIDOR PARTITION TO REMAIN.
CODE C( n et rop
App c a A 20
S ICM
at VII DIt D
EXISTING B/S CONSTRUCTION TO REMAIN.
EXISTING B/S DEMISING PARTITION.
EXISTING CONSTRUCTION TO BE DEMOLISHED.
NEW B/S TENANT INTERIOR PARTITION: 31/2" METAL STUDS WITH 5/8" TYPE'X' GWB EACH
SIDE FROM FLOOR TO UNDERSIDE OF HUNG CEILING. SEE DETAIL 4/TI -1.
SYMBOL
FIXTURE
DESCRIPTION
NUMBER OF
EXISTING
FIXTURES
NUMBER OF
FIXTURES
REMOVED
NUMBER OF
RELOCATED
FIXTURES
NUMBER OF
FIXTURES
ADDED
I
2'x4' RECESSED
FLUORESCENT
FIXTURE
90
0
17
0
0
DOWNLIGHT
FIXTURE
11
0
0
0
0
WALL WASH
FIXTURE
2
0
2
0
TOTALS
103
0
17
0
r
SOUTHCENTER
CORPORATE SQUARE
BUILDING 1
545 ANDOVER PARK WEST
TUKWILA, WASHINGTON 98188
6852 ; ._.. ... ,.w ......
REGISTERED, .
ARCHITECT
:.:'1PDONAHOU
TE OF WASHINGTON
Marvin Ste .1 .sociates, LLc
planning design
desi n
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
DRAWN BY: TN, AP JOB NO.: 99135.050
PERMIT SET
CHECKED BY: SN DATE: 08/27/07
SCALE: AS NOTED
REVISIONS /ISSUANCE:
NO. R
REVISIONS INDICATED THUS n D
DATE
PERMIT SET 8
8/27/07
CONSTRUCTION SET 1
10/01 /07
A R
REVISION SET 1
10/02/07
�
TENANT:
COMPUPAY
RECEIVED
CITY OF TUKWILA
OCT 1-3 2007
`'EF i.:: T CES TEF
SHEET TITLE:
E
w
REPRODUCTION, ALTERATION OR PUBLICA11ON OF THIS
TI-4
1—
(8)
1 117 1—
LIGHTING WORK ONLY
NO CEILING GRID WORK IS TO BE DONE,
ALL EXISTING GRID MEMBERS
ARE TO REMAIN U.N.O.
1 103 1 [ 104 1
H 116
H 105
n
NOT IN CONTRACT
� W o SEEM
MEEK
1
maim=
1
■■.i � _ ® N
■ ��
�ui
A _a
mo_iii ■I --
a- 21 1 " ■I■-■
i� ■I ■I
�� �I�i� ■I IIIIIII�
EMI=
I
NOT IN CONTRACT
111
SCALE: 1/8" =1' -0"
0
—1 115 1
FIRST FLOOR PLAN
CEILING KEYNOTES:
114 I
NORTH
5' 10' 20' 30'
O PROPOSED MASTER SUITE SWITCH LOCATION.
Q ABANDON EXISTING LIGHT SWITCH. PULL WIRES AS REQUIRED. FINISH AS
REQUIRED. SEE RELATED CONSTRUCTION KEYNOTE.
0 MODIFY DIRECTION OF EXISTING EXIT SIGN TO COMPLY WITH THIS PLAN.
Q 4 PROVIDE NEW B/S LIGHT SWITCH(ES), IF NOT ALREADY EXISTING.
110
GENERAL CEILING NOTES:
1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL
CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT
WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN
ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR
IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY
MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES
ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED.
2. CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING. THE MEANS OF
EGRESS ILLUMINATION SHALL NOT BE LESS THAN 1 FOOT- CANDLE (11 LUX) AT THE FLOOR
LEVEL.
3. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE
TO CURRENT CODES AS NECESSARY.
4. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS
NECESSARY.
5. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF
LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS
IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES
AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH
EXISTING AS REQUIRED.
7. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AREAS AS DEFINED IN CHAPTER 12, BOTH
UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED
WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC
CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING
AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE.
8. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND
CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS,
SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED.
9. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE
DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF
CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING
CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS,
EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE
WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST
PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER.
DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE.
SWEEP CONTROLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS
REQUIRED.
10. ALL ASPECTS OF THE DESIGN & CONSTRUCTION OF THE HVAC SHALL BE PERFORMED
BY THE CONTRACTOR.
11. ALL LIGHTING AND CONTROLS SHALL BE B /S, UNO.
12. CONTRACTOR SHALL SATISFY THE LIGHTING SPECIFICATIONS BASED ON THE
AVAILABLE ELECTRICAL VOLTAGE.
13. ALL B/S EXIT LIGHTS SHALL BE "LED" STYLE AND LESS THAN 5 WATTS /FIXTURE, UNO.
14. RE -USE EXIT SIGNS AS POSSIBLE.
15. RE- CIRCUIT SWITCHING OF EXISTING LIGHTING AS NECESSARY TO COMPLY WITH NEW
LIGHTING LAYOUT.
16. EMERGENCY LIGHTING SHOWN IS CONCEPTUAL ONLY. LIGHTING CONTRACTOR TO
PROVIDE DESIGN.
CEILING LEGEND:
EXISTING ACOUSTICAL CEILING TILE AND GRID
EXISTING GWB CEILING
EXISTING 2'x4' RECESSED FLUORESCENT LIGHT FIXTURE.
EXISTING 2'x4' RECESSED FLUORESCENT LIGHT FIXTURE TO BE
RELOCATED.
RELOCATED 2'x4' RECESSED FLUORESCENT LIGHT FIXTURE.
2'x4' RECESSED FLUORESCENT LIGHT FIXTURE FOR EMERGENCY
LIGHTING. EMERGENCY LIGHTING IS CONCEPTUAL ONLY. ELECTRICAL
CONTRACTOR TO PROVIDE DESIGN.
0 EXISTING DOWNLIGHT FIXTURE TO REMAIN.
EXISTING WALL WASH FIXTURE TO BE RELOCATED.
R RELOCATED WALL WASH FIXTURE.
0 (N) EXISTING, U.N.O., B/S EXIT SIGN (N =NEW) (DIRECTIONAL WHERE
SHOWN).
169- (N,3) EXISTING, U.N.O., B/S WALL LIGHT SWITCH (N -NEW) (3 =3 -WAY).
LIGHTING CALCULATIONS:
PERCENTAGE OF RELOCATION
19 RELOCATED FIXTURES / 103 EXISTING FIXTURES x 100% =18 %
SUMMARY
PERCENTAGE OF RELOCATION IS LESS THAN 60% ALLOWED PER WSEC.
61 -57-°'
r
n
c�2
c1� t o ,
W
ELEVATION @ BREAK ROOM
NA
101 NA NA
NA
NA
11 I NA
PROVIDE B/S P -LAM
SUPPORT AS REQUIRED.
TYPICAL ELEVATION @ DISTRIBUTION ROOM
B/S 24" DEEP PLAM
UPPER CABS. WITH
DOORS AND (2) ADJ.
SHELVES.
18" DEEP PLAM SHELP
EXISTING LOWER
CABINETS
X 36" MAX.
NOTE:
PROVIDE FINISHED ENDS AT ALL
EXPOSED ENDS.
4" PLAM BACKSPLASH
PROVIDE B/S 24" DEEP PLAM WORK
SURFACE WITH BOX, FILE, & FILE PEDESTAL
AT 3 LOCATIONS. COORDINATE IN/TENANT.
B/S 17 DEEP PLAM
UPPER CABS. WITH
DOORS AND (2) ADJ.
SHELVES.
NOTE:
PROVIDE FINISHED ENDS
AT ALL EXPOSED ENDS.
RELAMINATE EXISTING
CABINETS TO MATCH
NEW CABINETS. FINISH
TBD
3/8 " =1' -0"
TYPICAL ELEVATION OF WORK COUNTER
PROVIDE B/S P -LAM SUPPORT
AS REQUIRED. (36" MAX.)
CHROME METAL ROD
3/4" PAINTED WOOD SHELF &
SIDE PANELS W/ "TEE"
EDGING, TYP.
EQ. II EQ. . EQ.
PROVIDE 20 GA.
SHEET METAL
BACKING OR 2x4
TREATED WOOD
BLOCKING
PROVIDE B/S 24° DEEP
PLAM WORK SURFACE.
IF SPAN IS OVER 36 ",
ADD SUPPORT K AS
REQUIRED.
3/8 " =1' -0"
SOUTHCENTER
CORPORATE SQUARE
BUILDING 1
545 ANDOVER PARK WEST
TUKWILA, WASHINGTON 98188
sociates, LLC
design
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 - 1449
3/8 " =1' -0"
NA
NA
4 ELEVATION @ CLOSET
NA
121 NA
3/8 " =1' -0"
NA
NA
NA
131 NA
SECTION @ CLOSET
REVIEWED FOR
Co COMA
P1
CC /2
CM 0 Tul ila
3/8 " =1' -0"
NA
NA
NO.
DRAWN BY: TN. AP
CHECKED BY: SN
REVISIONS /ISSUANCE:
REVISIONS INDICATED THUS n
PERMIT SET
CONSTRUCTION SET
TENANT:
SHEET TITLE:
JOB NO.: 99135.050
PERMIT SET
DATE: 08/27/07
SCALE: AS NOTED
DATE
8/27/07
10/01 /07
C O M P U PAY RECEIVED
REPRODUCTION, ALTERATION OR PUBLICATION OF THIS
DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A
VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY
MS &A 2007.
CITY OF TUKWILA
OCT - 3 2007
:ENTER
FIRST FLOOR
ELEVATIONS AND SECTION
TI -5
OF 6
NOT IN CONTRACT
RECEPTION
CONFERENCE
ELEC)
COMMUN.
NOT IN CONTRACT
+50 AFF
+50 AFF
+50 AFF
+50 AFF :44 AFF
cm
+44 AFF
T
OFFICE OFFICE
1 1031— 1104J-
1 1 I 1 1 1
L�- - ± - - -J L— — ± —� —J
(7) TOTAL VOICE REQUIRED.
(4 TO BE DEDICATED TO FAX.)
OPEN WORK AREA
OPEN
WORK
AREA
H 116 1
COLUMN
COLUMN
COATS
OFFICE
H1 115 1
+38 AFF
+38 AFF
OPEN
WORK WORK
AREA AREA
— 1 105 1 — 1 109 1
OFFICE
— 1 114 1
FILES
(_p i.o (I)
(, 4
ti) t 471 ; 7
N N N N N N N N t\
W LL U- W I-1- 1- W U
z., m zm o z
9' -0
ELEC. /COMMUNICATIONS PLAN
SCALE: 1/8 " =1' -0°
NORTH
OPEN
WORK
AREA
Ft1T1
OFFICE
COURIER
PICK -UP
AREA
STORAGE
GENERAL ELEC./ COMMUNICATION NOTES:
1. REUSE OPENING AT BLANK FACE PLATES (BFP) AND OPEN BOXES (OB) AS POSSIBLE.
2. AT OUTLET LOCATIONS TO BE REMOVED, PULL OR CAP WIRES AS REQUIRED BY CODE.
3. EXISTING FACE PLATES AND JUNCTION BOXES/WALL OPENINGS NOT USED ARE TO BE
REMOVED (TYPICAL), WALL FILLED & PATCHED TO LIKE NEW WALL CONDITIONS.
ELEC. /COMMUNICATIONS KEY NOTES:
0 REMOVE ELECTRICAL AND COMMUNICATIONS OUTLETS.
ELEC. /COMMUNICATIONS LEGEND:
BIS WALL MOUNTED QUAD ELECTRICAL OUTLET
• BIS WALL MOUNTED DEDICATED QUAD ELECTRICAL OUTLET
B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET
1 B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET
B/S WALL MOUNTED JUNCTION BOX
• B/S WALL MOUNTED COMBINATION VOICE/DATA OUTLET
1-1 B/S WALL MOUNTED DATA OUTLET
I B/S WALL MOUNTED VOICE OUTLET
�F B/S WALL MOUNTED DEDICATED FAX OUTLET
®PP POWER POLE
BFP
Og
'N'
# NEW WALL MOUNTED VOICE/DATA CONNECTION TO TENANTS FURNITURE PANEL
# SYSTEM (1) VOICE AND (1) DATA LINES PER WORKSTATION).
Q (NUMBER = QUANTITY OF WORKSTATIONS SERVED).
NEW WALL MOUNTED JUNCTION BOX CONNECTION TO TENANTS FURNITURE PANEL SYSTEM -
POWER FOR (1) DUPLEX ELEC. OUTLET PER WORKSTATION.
(NUMBER = QUANTITY OF WORKSTATIONS SERVED).
BLANK FACE PLATE
OPEN BOX (NO COVER PLATE)
NEW
SOUTHCENTER
CORPORATE SQUARE
BUILDING 1
545 ANDOVER PARK WEST
TUKWILA, WASHINGTON 98188
PERMIT SET
TENANT:
SHEET TITLE:
planning
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441-1449
DRAWN BY: TN, AP
REVISIONS /ISSUANCE:
NO. REVISIONS INDICATED THUS A
CONSTRUCTION SET
-T P. OOe4AJ1OU
OF WASHiNGTON
design
COMPUPAY
REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS
DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A
VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY
MS &A 2007.
JOB NO.: 99135.050
PERMIT SET
CHECKED BY: SN DATE: 08/27/07
SCALE: AS NOTED
8/27/07
10/01/07
FIRST FLOOR
ELEC./COMMUNICATIONS PLAN