HomeMy WebLinkAboutPermit D07-384 - SIDHU HOMES - NEW HOUSESIDHU HOMES 4637 S 148 ST D07 -384 Parcel No.: 0042000135 Address: 4637 S 148 ST TUKW Suite No: Tenant: Name: SIDHU HOMES Address: 4637 S 148 ST , TUKVVILA WA City -f Tukwila Owner: Name: SIDHU HOMES INC Address: 4224 S 148TH ST , TUKWILA WA 98168 Phone: Contact Person: Name: GARY SINGH Address: 4224 S 148 ST , TUKWILA WA 98168 Phone: 206 244 -1900 Contractor: Name: SIDHU HOMES INC Address: 14641 46 AV S , TUKWILA WA 98168 Phone: 206 - 244 -1900 Contractor License No: SIDHUHI980NO Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Permit Number: D07 -384 Issue Date: 11/14/2007 Permit Expires On: 05/12/2008 Expiration Date: 08/30/2008 DESCRIPTION OF WORK: CONTSTRUCTION OF A NEW 3608 SF SFR WITH 612 SF ATTACHED GARAGE PUBLIC WORKS ACTIVITIES INCLUDE: TESC, LAND ALTERING, STORM DRAINAGE W/ INFILTRATION, UNDERGROUNDING OF POWER, AND DRIVEWAY. WATER DIST. 125 & VALLEY VIEW SEWER Value of Construction: $365,312.84 Fees Collected: $7,008.61 Type of Fire Protection: NONE International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 22 doc: IBC - 10/06 * *continued on next page ** D07 -384 Printed: 11 -14 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: Y Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: Y Volumes: Cut 50 c.y. Fill 50 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: Y Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or performance of work. I am authorized to sign and obtain this development permit. Signature: Print Name: doc: IBC -10/06 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us x Date: Permit Number: D07 -384 Issue Date: 11/14/2007 Permit Expires On: 05/12/2008 tti Date: i) L/ U 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -384 Printed: 11 -14 -2007 Parcel No.: 0042000135 Address: 4637 S 148 ST TUKW Suite No: Tenant: SIDHU HOMES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D07 - 384 Status: ISSUED Applied Date: 10/10/2007 Issue Date: 11/14/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until fmal inspection approval is granted. 5: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 8: All wood to remain in placed concrete shall be treated wood. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 12: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 13: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 14: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 15: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. doc: Cond -10/06 D07 -384 Printed: 11 -14 -2007 16: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 17: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 18: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 19: ** *FIRE DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 20: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 21: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 22: All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (IFC 503.1, 508.1) 23: Adequate ground ladder access to rescue windows shall be provided. 24: Maximum grade for all projects is 15 %. 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 27: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 28: Contractor shall notify Public Works Project Inspector Mr. Greg Villanueva at (206)433 -0179 of commencement and completion of work at least 24 hours in advance. 29: Work affecting traffic flows shall be closely coordinated with the City Utilities Inspector. Traffic Control Plans shall be submitted to the Inspector for prior approval. 30: The City of Tukwila has an undergrounding ordinance requiring the power, telecommunications, and cable service lines be underground from the point of connection on the pole to the house. 31: Any material spilled onto any street shall be cleaned up immediately. 32: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 33: The Land Altering Permit Fee is based upon an estimated 50 cubic yards of cut and 50 cubic yards of fill. If the final quantity exceeds this amount, the developer shall be required to recalculate the final quantity and pay the difference in permit fee prior to the Final Inspection. doc: Cond -10/06 D07 -384 Printed: 11 -14 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 34: From October 1 through April 30, cover any slopes and stockpiles that are 3H: IV or steeper and have a vertical rise of 10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. 35: Downspouts, driveway, patio and drainage from other impervious areas shall be collected in an on -site storm drain system. Drains shall be 4" minimum diameter, PVC schedule 40 or corrugated poly ethylene pipe with a minimum 1% slope for gravity discharge to location approved by the Public Works Department. Downspouts shall not connect to footing drains. Footing drain and downspouts may share a single discharge pipe downstream of the lowest footing drain. 36: Driveways shall comply with City residential standards. Driveway width shall be a 10' minimum and 20' maximum. Slope shall be a maximum of 15 %. Turning radii shall be a minimum of 5'. 37: Owner /Applicant shall contact the local postmaster regarding location of mail box(es) installation. Location of mail box(es) installation shall be coordinated with Public Works. 38: PAVEMENT MITIGATION FEE MAY APPLY TO THIS PERMIT. AS PART OF PUBLIC WORKS FINAL, PUBLIC WORKS PROJECT INSPECTOR WILL MEASURE PAVEMENT CUT, IF APPLICABLE, FOR FINAL PAVEMENT MITIGATION FEE CALCULATION. 39: THERE IS NO WORK EXPECTED WITHIN THE PUBLIC RIGHT-OF-WAY AND THEREFORE PUBLIC WORKS DOES NOT REQUIRE (1) ROW HOLD HARMLESS AGREEMENT (2) INSURANCE FOR WORK WITHIN THE PUBLIC RIGHT -OF -WAY (3) BOND FOR WORK WITHIN THE PUBLIC RIGHT -OF -WAY. DURING CONSTRUCTION IF PUBLIC RIGHT -OF -WAY WORK IS NEEDED, THEN OWNER/APPLICANT SHALL PROVIDE ITEMS 1 THRU 3 ABOVE, PRIOR TO STARTING THE WORK. 40: ** *PLANNING DEPARTMENT CONDITIONS * ** 41: Please note that you are proceeding at your own risk by obtaining a building permit prior to any future short plat application you may be considering. The City is making no warranties and is providing no guarantees that a short plat may be approved at a future date. The home approved under this building permit will be required to comply with all basic development standards in place at the time of the filing of a complete short plat application. doc: Cond -10/06 * *continued on next page ** D07 -384 Printed: 11 -14 -2007 Signature: er e w- Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: )///W D07 - 384 Printed: 11 -14 -2007 CITY OF TUKWILA Community Development Department Public Works Department Pennit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http :!/www. ci. tukwila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 1/6 ( -*l Tenant Name: -- Property Owners Name: Mailing Address: tJN(J qoil4S � % xi c. Li 124 SNAEL \ tL s{-. King Co Assessor's Tax No.: 1)0 '1 000135 S Floor: City Name: Mailing Address: G ARy S mig N As Above_ City E -Mail Address: S & �� 1�. } .t 1 etTaxNumber. 2010 State t4 g Zip g '�- Contractor nfut tiouforSMechanicali( }forPlumbi Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Q :1Applieationstromu- Applications On Linet3 -2006 - Permit Apptication.doc Revised: 9 -2006 bh 1 D t-1 L3 -V\ >ti1 S r r c_ A5%. Ato:sv C._- ThlYtH 1 Ll.c rr► E S ti G'J t o �a 1 � 6to, Pi Contact Person: .�'1� d ��! w►�, E -Mail Address: Day Telephone: Z b 19kA-141 CIO City Suite Number: Contact Person: E -Mail Address: civ aA_ ( � c>s,.... Coni • Ala } Fax Number: Contractor Registration Number: S i U H rig 0 'JO Day Telephone: Expiration Date: New Tenant: ❑ Yes ❑..No - { V t.,i L sc�ce �� c781(-1% State Zip 20 1, O%- 3e- 2c3C Al t C TEC'T AF REC t_ utmost:. be vet Slav Company Name: rG Ce, S. � Macv -t }- p. a . 59 ,' a ✓e. Sea ft Tv�wi t fl Mailing Address: City State Zip tub'- 9 L % -0192._ City Day Telephone: Fax Number: gmee r. i ltd, State Zip Day Telephone: 2 0l, — 2)f2— ^j ( 45 Fax Number: sam Page 1 of 6 Valuation of Project (contractor's bid price): $ a. 003 9 S o Existing Building Valuation: $ 4 Scope of Work (please provide detailed information): ?.c,..l -S . Si i Pa 1 Re 4„ ez (P� Will there be new rack storage? ❑ Yes 13,.. No If yes, a separate permit and plan submittal will be required. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, nrovide the following: Lot Area (sq ft): 30 X floor area of principal dwelling: I. sr Floor area of accessory dwelling: *Provide doatrnentati that shows tha the principal owner lives in one of the lings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact Handicap: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Q:MpplicalionlPonro- Applications On Line \3 -2006 - Permit Appliwion.doc Reviled: 9 -2006 bh No If `yes ", explain: ❑ Sprinklers ❑ Automatic Fire Alarm fig, None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Er No If "yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Scope of Work (please provide detailed information): t\1 44-J C" .zit.. . . F. j2eS-i A cam. Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. ukwila VWater District #125 `Water Availability Provided Sewer District ❑ ...Tukwila [ Va1Vue ❑ ...Sewer Use Certificate Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. T Sub fitted with Application (mark boxes which apply): ... Plans (Maximum Paper Size —22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours \ ❑ . ght-of -way Use - No Disturbance ...Construction /Excavation/Fill - Right -of -way Non Right -of -way •/ 15,Rotal Cut 8' Total Fill 5 cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation » Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporar Water Meter Size . ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public „ „ 0. 0. o. 0. FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 1 ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: WA T4 4 i' 114 /t,. D':5 i- • / II, Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City Day Telephone: City State State Zip Zip QtApplicationslFonns- Appliestioe. On Line%3 -2006 - Permit Appliertion.doe Revised: 9 -2006 bh » Call before you Dig: 1- 800 -424 -5555 . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ .. Highline ❑ .. Renton ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .,,Work in Flood Zone rIV Storm Drainage ❑ .. Renton ❑ .. Seattle ❑...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization •Tench Excavation Utility Undergrounding WO # WO # WO # ❑...Deduct Water Meter Size Private Private Page 3 of 6 bh Contractor Registration Number: Use: Residential: Commercial: Unit Type: Fumace<100K BTU Fumace>100K BTU Floor Furnace Qly MECHANICAL CONTRACTOR INFORMATION Company Name: AV 4 aL 4 A t.-L. Mailing Address: 5 5 2 3 S 3 4 Si- Contact Person: V4153-ta � /7 Of , ! E -Mail Address: Valuation of Mechanical work (contractor's bid price): $ ! 500 0� Scope of Work (please provide detailed information): /J Fuel Tvve: Electric ❑ Gas....RI Other: Indicate type of mechanical work being installed and the quantity below: Suspended/Wall/Floor Ventilation System Mounted Heater Appliance Vent Z Hood and Duct Hea or ri Addig/Cootion li to Incinerator - Domestic System Air Handling Unit <10,000 CFM Incinerator — Comm/1nd Q:UppliwimsWonns- Appliatian On leneU -2006 - Permit Appfiwion.doc Revised: 9 -2006 'ERNAT TF RM ;� N b -43i 7 0 VHEA mi A 4 753 D8 New .... glf Replacement .... ❑ New .... ❑ Replacement .... ❑ Unit Type: Air Handling Unit >10,000 CFM Evaporator Cooler Ventilation Fan Connected to Single Duct Qty Unit Type: Fire Damper I Diffuser Thermostat Wood/Gas Stove Emergency Generator Other Mechanical Equipment City I 2 State Zip Day Telephone: 2 5 3 Fax Number: °Y Z-S 3 �. Expiration Date. °3 s Qty Boiler /Compressor 0-3 HP /100,000 BTU 3 -15 HP /500,000 BTU 15 -30 HP /1,000,000 BTU 30 -50 HP /1,750,000 BTU 50+ HP /1,750,000 BTU Page 4 of 6 ``Flitur_e F pe.... Oty - ixture`hpe. Qty .., :FIxturefi pe..., ;. EM F xtuare'Type QfY Bathtub or combination bath/shower , , '' Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets L I Bidet Food -waste grinder, commercial $ Receptor, indirect waste Clothes washer, domestic I Floor drain Sinks it l Dental unit, cuspidor Shower, single head trap ) Urinals Dishwasher, domestic, with independent drain Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type _grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas N UMBING W GAS P Pte G P, RMIT ;INFORMATION 206-431-36 PLUMBING AND GAS PIPING CONTRACTOR INFO ATION J / 1 1(. Company Name: M tl.2f:. tn.. Pi Mailing Address: 2°9 U , S ' - 1- SQ w Q 1., ;J-4 tJQ '` S e 3 9 City State Zip Contact Person: 2 \\ 'Y E eM . Day Telephone: / Z S 71 '3 -1(0 23 E -Mail Address: Fax Number: Contractor Registration Number M AJ2 1 * Imo M Expiration Date: 0 1 , O Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): 7560 `- sob c — Alew Si 2,17 r>r Building Use (per Int'l Building Code): I gC' 1 • f Occupancy (per Int'l Building Code): s� "'f >L ca- -z 17 l" " x • Utility Purveyor: Water: liv 6-1-e,, 1 / Sewer: V' [ e- CeA.i � T Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:NpplicanonslF0nm- Application On Line - Permit Application.doc Revised: 9 -2006 bh Fa 4..,,.1 Re sieiri, ee Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGE Signature: 9 / (8lo *:) - Date: d t Q6) 03- Print Name: G UYA'ID Day Telephone: gob — 2 Y y / f a Mailing Address: £ a SD t, 171 Sr? 61 .51:7 ''1c A - Sti d O / City State p Date Application Accepted: I o 01-7 Q1Applicabons \Forms - Applications On LineO -2006 • Permit Application.doc Revised: 9 -2006 6h Date Application Expires: t 0 Q 1 - Staff Initial:.- t Page 6 of 6 Doc: RECSETS -06 RECEIPT NO: R07 -02481 Initials: JEM User ID: 1165 Payee: SIDHU HOMES, INC. SET ID: 1114 SET NAME: SIDHU HOMES SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us D07 -384 4,588.90 M07 -215 175.56 PG07 -269 364.50 TOTAL: 5,128.96 TRANSACTION LIST: Type Method Description Amount Payment Check 2002 ACCOUNT ITEM LIST: Description SET RECEIPT TOTAL: Payment Date: 11/14/2007 Total Payment: 5,128.96 5,128.96 5,128.96 Account Code Current Pmts BUILDING - RES 000/322.100 3,078.02 GAS - RES 000/322.100 88.00 MECHANICAL - RES 000/322.100 175.56 PLAN CHECK - RES 000/345.830 7.50 PLUMBING - RES 000/322.100 269.00 PW LAND ALT PERMIT FEE 000/342.400 23.50 PW PERMIT /INSPECTION FEE 000/342.400 169.00 STATE BUILDING SURCHARGE 000/386.904 4.50 TRAFFIC CONCURRENCY 104.367.121 00 300.00 TRAFFIC MITIGATION FEES 104.367.120 1,013.88 TOTAL: 5,128.96 4979 11/14 9710 TOTAL 5128.96 Dnc: Rrcsomos RECEIPT NO: R07 -02210 User ID: 1165 Payee: SIDHU HOMES, INC. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us SET RECEIPT Initials: JEM Payment Date: 10/10/2007 Total Payment: 2,530.10 SET ID: S000000875 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -384 2,419.71 M07 -215 36.39 PG07 -269 74.00 TOTAL: 2,530.10 TRANSACTION LIST: Type Method Description Amount Payment Check 1955 2,530.10 TOTAL: 2,530.10 ACCOUNT ITEM LIST: Description PLAN CHECK - RES PW BASE APPLICATION FEE PW PLAN REVIEW Account Code Current Pmts 000/345.830 2,111.10 000/322.100 250.00 000/345.830 169.00 TOTAL: 2,530.10 • ; ;t i0 TTAL COMMENTS: re_rp&71 Co J-- (4. / -'' ijc-r1 5 L., ,,, t SU 2 1 R A / A-0 c _k A-I ( i ) 1 1 1\4k PI 0, 0 e X i Special Instructions: ' / r ,(1 Requester: P hone No: _ - tod I 1 l Pler tw _( ma Type of Inspectipn: EA IA SU 2 1 R A / Address: - ,_pate 03 50A f4 A i Called: / Special Instructions: ' / Date Wanted: ,(1 Requester: P hone No: _ - tod INSPECTION RECORD Retain a copy with permit ri , Do -3N INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 9— 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approved per applicable codes. Corrections required prior to approval. 'Date: I Lc El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Proje :., / Type of �� Inspection: Ar s J. A k es: ,3`? S 1 4& 5�c iled: / Special Instructions: 643 n-el f r .( l o� if-( —/ et-te-AT Date Wanted: - Z -n -- 0 a.m. Requester: Phone No: Pr INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspect!: ' 4 I Date: L El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Pro ,fn' i1��(/ffic T j22b e l� n . - -�Z- Addre s; In 5 7 /'g Date Called: Special Instructions: Date Wanted: ma rts . zc - 6e 1-rtf Requester: Phone No -.p6 Z W- 7'.0' INSPECTION RECORD *' Retain a copy with permit ,D67-18 INSPECTION NO. PERMIT NO. / CITY OF TUKWILA BUILDING DIVISION t - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 'Date: U $60.00 REINSPECTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd uite.a00. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Type of Inspection: .S , Address: L)- f. /-f 1' L J. i Ai UJA 1/ • -1:1 -F — ..- r° (--'-‘ ( '\"\---/ Special Instructions: ./' - V 4 , J . „zi 1 42: A -, u ALif . Ne ,4_11 - /1-1-> cP / , 6 (,...*.,-(. _--/- . ct: . Proje /-.) 14 • Type of Inspection: .S , Address: L)- f. /-f 57 Date Called: Special Instructions: ./' Date Wanted P.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. A !Date: - 1 - PERMIT NO. 7•• (206)431-3670 $58.00 REINSPECTION FE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pro le,c1; , ••• i!)//2/ /7 < Type of Inspection: 414/"- Address: 4//37 S /1/2:' 5-4 Date Called: Special Instructions: . , / Date Wanted: c2- - 28 dr6r) a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it* 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: rate) ;lip 0 l Inspeetor: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: _S7‘)2//-/ / Type of Inspection: /2 Addre 6 3 7 S / v2 s-, Date Called: } Special Instructions: / Date Wan - Z- Q ( a.rrr p.m. Requester: Phone No oG -21- /16v IlnsPrtor: L< /� ✓ !V } 1Date:2 - Z 6 .. V y INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: At t 7 ofre (.-I dA. f I■ v e ((2A :144, 11 $58.00 REINSPECTION FEE REQU`RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: i.)d 7 INSPECTION RECORD with permit I Xr ? I Retain a copy P PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION le-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 4= Proj t: /, (\ cJ 11 itvte 5 A 4� � S 14 Special Instructions: Type of Inspection: St ^ � om Date Called: Date Wanted: 2_ ' (� p.m. Requester: Phone No: /Approved per applicable codes. Corrections required prior to approval. COMMENTS: I lnspec or: ` 1 'Date: Z , 2 ( — )(I/ I El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Date: (Receipt No.: COMMENTS: T�y� of Inspection: WR( j(A('6 Addres (_3 I 1 J . 14 y , Th (,/:1 tl /� % yam- j 4 1 � G,6 /r (( - 1---__IA f I, h, r S-F, -_J-, A -I..E . Phone No: Project: S v\ ,+ // l>A S T�y� of Inspection: WR( j(A('6 Addres (_3 I 1 J . 14 y , Th Date Called: Special Instructions: Date Wanted: t_ I I% d r a J m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. (Inspect El $58.00 REINSPECTION FEEREQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: ���_ Project: Type of Inspection: ,3 Address: 4(0 3 i C /i � 5 Date Called: —. Special Instructions: Date Wanted: C ) 2 , I c) a„ .. m; Requester: Phone Nom /q0 d INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R- 6 3 0 0 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspect or� !Date: 2 / � J $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: fr , q _. 9r , e) ...,, br _ bl 0 pp-el &of Aef ye 2- _Ste.' A tjil or ,s (71 Full le-A114. z/.3 7 ,S" / Yeg Special Instructions: n7- a.m. Requester: Phone No ) A-rs-h -kb 44.' /7 C , i o-K )(A. felt/ Pr*ct: . „ /( 2/ /1 Oft cS Type of Inspection: (A / 4 Li Sire 1 % 1 14/5 Addres Date Called: z/.3 7 ,S" / Yeg Special Instructions: Date Wanted: a.m. Requester: Phone No INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-36 Approved per applicable codes. 12167rections required prior to approval. Inspec r IDate: $58.00 REINSPECTION EE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: Project: , W NO nn ,C� of Inspection: ize . ,....w4 - /fl ,;(./. Ad dress zi63 „ 7 5 / y � S � Date Called: Special Instructions: Date Wanted: -- / / O 0 (a.n1. p.m. Requester: Phone N : .206 - Z4U -/9 2() I Do 2 -32N NSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 1 Inspectr: (Date' — 1 -a $58.00 REINSPECTIbN FESREQl1IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: Project; /-7(orii Type of Inspection: 2 /40evi /oo✓ - j,Pq7fria, Address; Date Called: Special Instructions: Date Wanted: /Z / 7/7 a."m' Requester:. Phone Ng; Z- 4 - zyy fie/ 0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. P NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 y ?r14A-t/e( 8.00 REINSPECTION FEE REQPRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd .'Suite 100. Call the schedule reinspection. i7 -38 ps, p proved per applicable codes. 0 Corrections required prior to approval. COMMENTS: (Receipt No.: 'Date: Pro ct: II�L1 ��D F� Type of Inspection; `� ( Di `N L) lIs Address: I-(&3 S I `I ej Date Called: Special Instructions: Date Wanted: _ 11)Z - ((� ----? �, Reques r• Phone 2o( ZL1ti _60r) INSPECTION RECORD Retain a copy with permit ip 35q INS E CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PERMIT NO. V . proved per applicable codes. El Corrections required prior to approval. COMMENTS: I cfr, X00 REINSPECTION ftE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: SI .3,CAN 2 £yD lc.. Type of Inspection: VD w pkt../.. s Address: c `� 4 (... S 1 `"1,S -- s Date Called: k Special Instructions: Date Wanted: �( /Zt a.m. 01 p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Approved per applicable codes. Corrections required prior to approval. I f �GI ) 2 Date: -- \k /t(crI $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: 1. INSPECTION RECORD Retain a copy with permit jr INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- Project: Ad d7: Special Instructions: Type of rectio7— Date Called: Date Wanted: 4 / — P.m. Requester: Phone No: COMMENTS: 'Date: pproved per applicable codes. Corrections required prior to approval. $58.00 R NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: J ! IZ� °5 Type of Ins ec rt�tl r 1/ ieci Address: !f(p Nef St , Date Called: D& f)-a/oek Special Instructions: Ch e r p 9✓P41(14 ✓ ifiV n --ee. Date Wanted: n6 1 ° 20 / 0 p.m Requester: r (1- Phone No: aol ,7$ INSPECTION RECORD Retain a copy with permit CI 6300 Southcenter Blvd., #100, Tukwila, WA 98188 OF TUKWILA BUILDING DIVISION a ❑Approved per applicable codes. �v COMMENTS: C' - (i?-fO 2 le/P/ t if 41444 Ac ,J,c (( LA ,ii_y‘ Inspector: 'Receipt No.: nAI Date: / / $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter lvd., Suite 100. Call to sch edule reinspection. Corrections required prior topproval. 'Date: / PERMIT NO. (206)431 -3670 1 Project: S'i b Stit Type of Inspection: : Address7 il /W Date Called: (11(1 Special Instructions: Date Wanted: 1.. 1 ( a.m. p.m. Requester (-\ a C ' Phone No: 50 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 LI Approved per applicable codes. PERMIT NO. (206)431-3670 Corrections required prior to approval. COMMENTS: 3/ 7/3 (U///J tA/cA, d/L !Inspector: !Date: 3 (2 7(4 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: 14 7 -7, COMMENTS: Type of 1 pection: 1 " tIh ( (k` u,.T Tt 4v ) /...t o_. g 0 `G --mot 5 < (N./K �J ` r T -\ L i. A-4 , Special Instructs ns: Date Wanted (� I rte` P.m. Reque p r: P e No 6) 414 -.. 191 Proje Type of 1 pection: 1 " Addr ss: g 0 I I t a t i- i' Date a led: I 11 10 fo2 Special Instructs ns: Date Wanted (� I rte` P.m. Reque p r: P e No 6) 414 -.. 191 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. (Inspector: INSPECTION RECORD Retain a copy with permit El Corrections required prior to approval. 'Date: D 73y\- PERMIT NO. $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: LA' Project: (11 Type of Inspection: S0 Address: tf l, -1 ;7 ` � � , ; 1 Date Called: II 1 n10n Special Instructions: Date Wanted: I ( t / a.m. p.m. Requester: Phone No: C INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY;OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: It f 0/1 (1 U.) II d Inspector: 'Date: ( �/ 0)7? El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: s ` r S� A S Sprinklers: Type of Inspection: Fel .,L Hood & Duct: Address: S 1 ei_q, i Pre -Fire: Contact Person: �,c 1 51 4643 _ , Suite #: Special Instructions: PAC\ L�ncl b Y7 , Phone No.: cc sS � 4R 'av+t Needs Shift Inspection: M I- 1 Sprinklers: Fire Alarm: Hood & Duct: Monitor: ' \ Pre -Fire: Permits: `. Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT :"\)0 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Approved per applicable codes. ri Corrections required prior to approval. COMMENTS: Date: L 20l o b Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 XPIat Q� 09 : 4/24/ 24' #i k - to e - RE C COMPLIANCE ANCE APPROVED NOV 13 2007 //VI C , v ter -....r 24 ■/a 166 z70/5 7 /3'0'.4 /-t �� mom/ L 1Z S ,pe7r."i /OAP $ � e = 2S 3-ny do Ps.c L = 4'0 -. ,9$ 6 0 ,oj-/ /'7.4 x, /e X /2" P €12 G /G a c74s "71 s 'c3 72c, It Lam vs_ /2" /2"C74? s < � /4" 0-00A-0v ; 5 ni)E 5 , 3m 720 l4 /6 z- S S 6i$- 30/5 "Ve c)0 C7- //. - J ) Tic .57/2.4 7_ I /6 ' (2- Fib C M' rte; b cs_3,acitoC: �• C " f y' al& ?3,5Szc 184 0 2 /7 �- & ` " el7-e S CITY OF TUIMIILA OCT 1 0 2007 / 2 ...)'PA/V n-i Fog PERMIT C • /,.f/°. c 7/0 I-/ 2 / 2 " `6 f' ot< ?/O '1 1L d v n o ( Z? a of - // r 122.Z �d Q, r 0 QS t oZ,�' t Q8� t o b 1` o 8t l= G'7 x°7/01 0 -= s Z 'v `--�► S 7/03 nemoaroorf ).....P.••■••■•■•••••J 1' SaA 1 1 9/ 5-y_2 64. 70 / / e Z, 2101,4.5.7- o Z 02 m cc) CD CD / A t 0 3 6 0 - o w presher0l.wsw level %d 1 of 2 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN i -10' -5' 0' 1 C &C52.1/61 8141 [ F) V 2964 `10 1972 H -1 1)7 7 t/27 (1 ' 4221 E-1 - ? 9 i V ? r ? 3598 D.1 1 690 6 • �sq.? 0 6072 L,T A -1 XS c9 T {5 8 C & C 26 / 32 111 1 10' - 15' WoodWorks® Shearwalls 2002 46.7 f � T }} -} } i f f Tf f f 4 t} I -1 G -1 .? A • it A A 4) A` 1 C & C 29 / 32.3 C &C26.2/32.3 25' 35 } f f f U U Mar. 24, 2006 11:33:48 75' 70' 60' 55' 50' 25' 20' 15' 10' 5' 0 55' 60' 3 /r presher01.wsw level %d 2 of 2 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN 67.7 -- 105.0 05.6 - 10032.5 - 99.999,9 27.4 - 67.7 } f 4" i f±! j 6 } 4 C & C `26 / 32 C & C 26 2 / 32.3 01\ • 757 6MMS"na. °6b D�' N 4649 co co pti 1872 M v °1 744 q -1 + 1. GC 26 / 32 -10' -5' 0' 5' 10' • 15' WoodWorks® Shearwalls 2002 ,44 i i i i = --78ee -82 65.8 — 8136.6 — 72.3 72.3 - - 3.5 99.9 - 24.7 -82 - 60.4 F -1 C &C26.2/32.3 35' N 45' V 40' ci Mar. 24, 2006 11:33:48 75' 70' 65' 60' 55' i 35' 30' 15' 10' 5' 0' -5' 4-4 presher0l.wsw level %d 1 of 2 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN -10' -5' 0' E -1 Woodworks® Shearwalls 2002 -■111111111 D -1 A -1 10' • 15' I -1 H -1 G -1 25' 35' 40' Mar. 24, 2006 11:26:34 75' 70' 50' 55 60' 65' 60' 55' 50' 35' 30' 25' 20' 15' 10' 5' 0' -5' -10' presher0l.wsw level %d 2 of 2 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN -10' 0' 5' 10' 15' WoodWorks® Shearwalls 2002 B -1 F -1 Mar. 24, 2006 11:26:34 75' 70' 65' 60' 55' 50' 45' 40 35' 30' 25' 20' 15' 10' 5' 0' -5' -10' 45' 50 55' WoodWorks(r) Shearwalls 2002 presher01.wsr Mar. 24, 2006 11:36:17 STORY INFORMATION Floor /Ceiling Wall Building Story Elevation[ft] Depth[in] Height[ft] Mass[lbs] Shear[lbs] 20.50 10.0" 11.67 10.0" 8.00 26159 3639 2.83 10.0" 8.00 37468 2724 2.00 Totals: 63627 6363 Ceiling Level 2 Level 1 Foundation BLOCK INFORMATION Block:Block 1 Location[ft]: Extent[ft]: Ridge Loc[ft]: Ridge Elev[ft]: BLOCK INFORMATION Block:Block 2 Location[ft]: 10.50 Extent[ft]: 23.50 Ridge Loc[ft]: 10.50 Ridge Elev[ft]: 7.65 DESIGN SETTINGS Design Code: IBC Wind Capacity Increase: Shear = 1.40; C&C Panels = 1.50; Withdrawal = 1.60 Wind: Sheathing capacities are added together Seismic: Use greater of strongest or twice weakest sheathing capacities. Seismic Load Reduction Factor = 0.70 Shearwall Relative Rigidities based on Flexible Design Holddown Forces based on Applied Force Max Shearwall Offset: Plan = 4.00'; Elevation = 1.67'; Height to Width Ratio = 3.50 SITE INFORMATION . IBC Occupancy: Category I; ASCE Equivalent - Category II WIND: ASCE -7 98 General analytic method for all buildings Design wind speed = 100mph; Exposure C; Enclosed building SEISMIC: ASCE -7 98 Equivalent Lateral Force Procedure Use Group I; Seismic Design Category D; Site profile class D Spectral response accelerations S1 = 0.400g, Ss = 0.750g Fundamental period T: T used = 0.178s; Approximate Ta = 0.178s; Maximum T = 0.303s Reliabiliy factor rho = 1.00; Response modification factor R = 6.00 MATERIALS by WALL GROUP Wall Sheathing [in] Fasteners: Grp Surf Material Thickness Or Size Type 1 Ext SS in OSB ? Vert ? Nail 2 Ext SS incl. OSB 7/16 Vert 8d Nail 3 Both SS incl. OSB 7/16 Vert 8d Nail Notes: 1. Capacity has been reduced according to IBC specific gravity adjustment. SHEARLINE DIMENSIONS Name Level Wall Design Group(s) 1 2 COMPANY 1 2 2 2 1 3 STRUCTURAL DATA PROJECT ROOF PANELS Overhang Mass 2 Stories Type Slope [ft] [lbs] 0.00 North Hip 30.0 1.00 0 20.00 South Hip 30.0 1.00 0 0.00 East Side 30.0 1.00 0 5.77 West Side 30.0 1.00 0 ROOF PANELS Overhang Mass 2 Stories Type Slope [ft] [lbs] North Side 18.2 1.00 0 South Side 18.2 1.00 0 East Hip 30.0 0.57 0 West Joined 150.0 1.00 0 Location [ft] X = Y = 0.00 0.00 0.00 20.00 20.00 Spacing[in] Edge Field Blkg ? ? yes 6 6 yes 3 6 yes Framing Members [in] Apply Species G Spacing Notes Hem -Fir 0.43 ? Hem -Fir 0.43 24 1 Hem -Fir 0.43 24 1 Extent [ft] Full Height Start End Sheathing [ft] 0.00 57.00 0.00 57.00 51.00 0.00 57.00 45.00 0.00 20.00 0.00 57.00 10.50 2 2 3 2 2 4 1 2 2 2 A 1 1 2 2 B 1 3 2 2 C 2 2 D 1 2 E 1 2 F 2 2 G 1 2 H 1 2 I 20.00 28.00 28.00 43.50 43.50 43.50 1 2 2 2 * WARNING - The shearwalls on this 0.00 57.00 20.00 20.00 31.50 10.50 57.00 11.50 10.50 57.00 10.50 57.00 43.50 10.50 57.00 41.50 0.00 0.00 20.00 0.00 0.00 20.00 0.00* 0.00 0.00 20.00 13.00 10.50 20.00 43.50 10.50 0.00 43.50 6.00 10.50 0.00 43.50 23.50 20.00 20.00 28.00 20.00 0.00 43.50 8.00 22.00 0.00 20.00 22.00 0.00 43.50 17.00 28.00 0.00 14.00 28.00 0.00 43.50 14.00 31.00 28.00 43.50 31.00 0.00 43.50 15.50 36.00 18.00 28.00 36.00 0.00 43.50 10.00 41.00 0.00 43.50 41.00 0.00 43.50 31.50 57.00 0.00 43.50 57.00 0.00 43.50 13.00 57.00 0.00 43.50 31.50 shearline and level do not have any segments between openings that satisfy the minimum height -to -width requirements LOADS WIND SHEAR LOADS Name Building Lev Profile Tributary Face Width[ft] Block 1 N Wall North 2 Line Block 1 N Wall North 2 Line Block 1 N Roof North 2 Line Block 1 N Roof North 2 Line Block 1 N Roof North 2 Line Block 1 N Roof North 2 Line Block 1 E Wall East 1 Line Block 1 E Wall East 1 Line Block 1 E Wall East 2 Line Block 1 E Wall East 2 Line Block 1 E Roof East 2 Line Block 1 E Roof East 2 Line Block 1 E Roof East 2 Line Block 1 E Roof East 2 Line Block 1 E Roof East 2 Line Block 1 E Roof ' East 2 Line Block 1 S Wall South 1 Line Block 1 S Wall South 1 Line Block 1 S Wall South 2 Line Block 1 S Wall South 2 Line Block 1 S Roof South 2 Line Block 1 S Roof South 2 Line Block 1 S Roof South 2 Line Block 1 S Roof South 2 Line Block 1 W Wall West 1 Line Block 1 W Wall West 1 Line Block 1 W Wall West 2 Line Block 1 W Wall West 2 Line Block 1 W Roof West 2 Line Block 1 W Roof West 2 Line Block 1 W Roof West 2 Line Block 1 W Roof West 2 Line Block 1 W Roof West 2 Line Block 1 W Roof West 2 Line Block 2 N Wall North 1 Line Location[ft] From To 0.00, 0.00 -1.00 -1.00 10.00 10.00 0.00 0.00 0.00 0.00 - 1.00 - 1.00 10.00 10.00 47.00 47.00 0.00 0.00 0.00 0.00 - 1.00 - 1.00 10.00 10.00 0.00 0.00 0.00 0.00 -1.00 =1.00 10.00 10.00 47.00 47.00 0.00 43.50 43.50 10.00 10.00 21.00 21.00 10.50 10.50 10.50 10.50 10.00 10.00 47.00 47.00 58.00 58.00 20.00 20.00 20.00 20.00 10.00 10.00 21.00 21.00 57.00 57.00 57.00 57.00 10.00 10.00 47.00 47.00 58.00 58.00 43.50 Magnitude Wind [lbs,plf,psf] Direction 63.4 Windward 21.5 Leeward 0.0 -65.7 Leeward 0.0 -25.8 Windward 65.7 -0.0 Leeward 25.8 =0.0 Windward 111.1 Windward 76.1 Leeward 63.4 Windward 41.7 Leeward 0.0 -65.7 Leeward 0.0 -21.9 Windward 21.9 Windward 65.7 Leeward 65.7 -0.0 Leeward 21.9 -0.0 Windward 111.1 Windward 39.2 Leeward 63.4 Windward 21.5 Leeward 0.0 -65.7 Leeward 0.0 -25.8 Windward 65.7 -0.0 Leeward 25.8 -0.0 Windward 111.1 Windward 76.1 Leeward 63.4 Windward 41.7 Leeward 0.0 -65.7 Leeward 0.0 =21.9 Windward 21.9 Windward 65.7 Leeward 65.7 -0.0 Leeward 21.9 -0.0 Windward 111.1 Windward Block 2 N Wall North 1 Line 0.00 43.50 46.7 Leeward Block 2 N Roof North 2 Line 6.75 20.57 0.0 -78.5 Leeward Block 2 N Roof North 2 Line 6.75 20.57 0.0 - -72.3 Windward Block 2 N Roof North 2 Line 20.57 30.25 -72.3 Windward Block 2 N Roof North 2 Line 20.57 30.25 78.5 Leeward Block 2 N Roof North 2 Line 30.25 44.07 78.5 -0.0 Leeward Block 2 N Roof North 2 Line 30.25 44.07 - 72.3 -0.0 Windward Block 2 E Wall East 1 Line 10.50 57.00 111.1 Windward Block 2 E Wall East 1 Line 10.50 57.00 76.8 Leeward Block 2 E Wall East 2 Line 10.50 57.00 63.4 Windward Block 2 E Wall East 2 Line 10.50 57.00 42.0 Leeward Block 2 E Roof East 2 Line 9.50 33.75 0.0 =83.2 Leeward Block 2 E Roof East 2 Line 9.50 33.75 0.0 -27.7 Windward Block 2 E Roof East 2 Line 33.75 58.00 83.2 -0.0 Leeward Block 2 E Roof East 2 Line 33.75 58.00 27.7 -0.0 Windward Block 2 S Wall South 1 Line 20.00 43.50 111.1 Windward Block 2 S Wall South 1 Line 20.00 43.50 46.7 Leeward Block 2 S Wall South 2 Line 20.00 43.50 63.4 Windward Block 2 S Wall South 2 Line 20.00 43.50 25.6 Leeward Block 2 S Roof South 2 Line 6.75 20.57 0.0 -78.5 Leeward Block 2 S Roof South 2 Line 6.75 20.57 0.0= =72.3 Windward Block 2 S Roof South 2 Line 20.57 30.25 -72.3 Windward Block 2 S Roof South 2 Line 20.57 30.25 78.5 Leeward Block 2 S Roof South 2 Line 30.25 44.07 78.5 -0.0 Leeward Block 2 S Roof 'South 2 Line 30.25 44.07 - 72.3 -0.0 Windward WIND C&C LOADS Name Building Level Magnitude [psf) Face Interior End Zone Block 1 N Wall North 1 26.0 32.0 Block 1 N Wall North 2 26.0 32.0 Block 1 E Wall East 1 26.0 32.0 Block 1 E Wall East 2 26.0 32.0 Block 1 S Wall South 1 26.0 32.0 Block 1 S Wall South 2 26.0 32.0 Block 1 W Wall West 1 26.0 32.0 Block 1 W Wall West 2 26.0 32.0, . Block 2 N Wall North 1 26.2 32.3 Block 2 N Wall North 2 26.2 32.3 Block 2 E Wall East 1 26.2 32.3 Block 2 E Wall East 2 26.2 32.3 Block 2 S Wall South 1 26.2 32.3 Block 2 S Wall South 2 26.2 32.3 BUILDING MASSES Name Shear Level Profile Tributary Location[ft) Magnitude Line Width[ft] From To [lbs,plf,psf] Wall 2 -1 2 1 Line 0.00 10.50 80.0 Wall A -1 A 1 Line 0.00 20.00 80.0 Wall 1 -1 1 1 Line 0.00 57.00 80.0 Wall I -1 I 1 Line 0.00 43.50 80.0 Wall 4 -1 4 1 Line 10.50 57.00 80.0 Wall B -1 B 1 Line 20.00 43.50 80.0 Floor Dl -E 1 1 Line 0.00 10.50 100.0 Floor Dl -W 2 1 Line 0.00 10.50 100.0 Floor D2 -E 1 1 Line 10.50 57.00 217.5 Floor D2 -W 4 1 Line 10.50 57.00 217.5 Floor D1 -S A 1 Line 0.00 20.00 285.0 Floor Dl -N I 1 Line 0.00 20.00 285.0 Floor D2 -S B 1 Line 20.00 43.50 232.5 Floor D2 -N I 1 Line 20.00 43.50 232.5 Wall I -1 I 2 Line 0.00 43.50 80.0 Wall 2 -1 2 2 Line 0.00 10.50 80.0 Wall A -1 A 2 Line 0.00 20.00 80.0 Wall 1 -1 1 2 Line 0.00 57.00 80.0 Wall 4 =2 4 2 Line 31.00 57.00 80.0 Wall B -1 B 2 Line 20.00 43.50 80.0 Wall 4 -1 4 2 Line 10.50 31.00 80.0 Block 1 N Roof I 2 Line - -1.00 21.00 295.0 Block 1 E Roof 2 2 Line -1.00 58.00 110.0 Block 1 S Roof A 2 Line , -1.00 21.00 295.0 Block 1 W Roof Block 2 N Roof Block 2 E Roof Block 2 S Roof Block 2 W Roof SEISMIC LOADS Name South 1 South 2 South 3 South 4 South 5 West 1 West 2 West 3 West 4 West 5 West 6 South 1 South 2 South 3 South 4 South 5 South 6 South 7 South 8 South 9 West 1 West 2 West 3 West 4 West 5 West 6 West 7 West 8 SHEARWALL SEGMENTS Name Lev Type Wall 1 2 Line I 2 Line 4 2 Line B 2 Line 2 2 Line Building Lev Profile Face South 1 Line South 1 Point South 1 Line South 1 Point South 1 Point West 1 Line West 1 Point West 1 Line West 1 Point West 1 Line West 1 Point South 2 Line South 2 Line South 2 Point South 2 Line South 2 Point South 2 Line South 2 Line South 2 Line South 2 Point West 2 Line West 2 Line West 2 Point West 2 Line West 2 Line West 2 Line West 2 Line West 2 Point Dimensions [ft] WIND DESIGN SHEAR RESULTS by SHEARLINE Line Lev Wall Wind Total Cumulative Shear Force Grp. Dir. FHS V[lbs] Unit V /FHS[plf] 1 1 2 S =>N 51.00 2939 51.6 57.6 2 2 Both 45.00 1361 23.9 30.2 2 1 3 S ->N 10.50 5877 103.1 559.7 2 2 N - >S 20.00 1763 30.9 88.2 3 2 2 N - >S 11.50 1108 23.8 96.3 4 1 2 N ->S 43.50 2941 63.2 67.6 2 2 N =>S 41.50 710 15.3 17.1 A 2 2 W - >E 13.00 744 37.2 57.2 B 1 3 W - >E 6.00 6072 139.6 1012.1 2 2 W = >E 23.50 1872 43.0 79.6 C 2 2 W ->E 8.00 2365 54.4 295.7 D 1 2 W - >E 17.00 3598 82.7 211.6 E 1 2 W - >E 14.00 4221 97.0 301.5 F 2 2 W - >E 15.50 4649 106.9 300.0 G 1 2 W - >E 10.00 2964 68.1 296.4 14 1 2 W ->E 31.50 1972 45.3 62.6 I 1 2 W ->E 13.00 4101 94.3 315.5 2 2 W ->E 31.50 2598 59.7 82.5 * WARNING design capacity has been exceeded. -1.00 58.00 19.00 44.07 9.50 58.00 19.00 44.07 9.50 58.00 FLEXIBLE DIAPHRAGM DESIGN 110.0 242.5 123.2 242.5 127.5 Location[ft] Magnitude From To [lbs,plf,psf] 0.00 20.00 37.2 0.00 0.00 232 20.00 43.50 29.8 20.00 20.00 43 43.50 43.50 189 0.00 10.50 18.3 0.00 0.00 81 10.50 31.00 30.3 10.50 10.50 48 31.00 57.00 30.3 57.00 57.00 177 -1.00 0.00 57.4 0.00 19.00 65.2 0.00 0.00 222 19.00 20.00 88.8 20.00 20.00 41 20.00 21.00 85.0 21.00 43.50 27.5 43.50 44.07 23.6 43.50 43.50 181 -1.00 0.00 21.4 0.00 9.50 29.2 0.00 0.00 78 9.50 10.50 53.6 10.50 31.00 53.6 31.00 57.00 53.6 57.00 58.00 45.8 57.00 57.00 169 Shear Capacity [plf] Inter Exter Perf Total 299.5 299.5 585.9 585.9 299.5 299.5 299.5 299.5 299.5 585.9 585.9 299.5 299.5 299.5 299.5 299.5 299.5 299.5 299.5 299.5 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 299.5 299.5 1171.8 299.5 299.5 299.5 299.5 299.5 1171.8 299.5 299.5 299.5 299.5 299.5 299.5 299.5 299.5 299.5 Full Height Perf Shear [lbs] Opening [ft] Response V /FHS /Tot 0.19 0.10 0.48 0.29 0.32 0.23 0.06 0.19 0.86 0.27 0.99 0.71 1.01* 1.00 0.99 0.21 1.05* 0.28 Group Location Start 1 -1 1 I 2 0.00 0.00 Opening 1 Opening 2 1 -1 2 I Opening 1 Opening 2 Opening 3 2 -1 1 I 2 -1 2 I 2 -2 2 I 3 -1 2 I 4 -1 1 I Opening 1 Opening 2 4 -1 2 , I 4 -2 2 I Opening 1 A -1 2 I Opening 1 B -1 1 I Opening 1 Opening 2 B -1 2 I C -1 2 I D -1 1 I Opening 1 E -1 1 I F -1 2 I G -i 1 I H -1 1 I Opening 1 Opening 2 I -1 1 I Opening 1 Opening 2 I -1 2 I Opening 1 Opening 2 Opening 3 End Sheathing Factor Force 57.00 51.00 1.00 2939 23.00 25.00 33.00 37.00 2 0.00 0.00 57.00 45.00 1.00 1361 13476 11.00 13.00 23.00 28.00 41.00 46.00 3 20.00 0.00 10.50 10.50 1.00 5877 12304 2 20.00 0.00 10.50 10.50 1.00 926 3144 2 20.00 10.50 20.00 9.50 1.00 838 2845 2 28.00 20.00 31.50 11.50 1.00 1108 3444 2 43.50 10.50 57.00 43.50 1.00 2941 13027 32.50 34.00 41.00 42.50 2 43.50 10.50 31.00 20.50 1.00 351 6139 2 43.50 31.00 57.00 21.00 1.00 359 6289 32.00 36.00 2 0.00 0.00 20.00 13.00 1.00 744 3893 6.50 13.50 3 10.50 20.00 43.50 6.00 1.00 6072 7031 20.00 26.50 30.00 41.00 2 10.50 20.00 43.50 23.50 1.00 1872 7037 2 • 20.00 20.00 28.00 8.00 1.00 2365 2396 2 22.00 0.00 20.00 17.00 1.00 3598 5091 10.00 13.00 2 28.00 0.00 14.00 14.00 1.00 4221 4192 2 31.00 28.00 43.50 15.50 1.00 4649 4642 2 36.00 18.00 28.00 10.00 1.00 2964 2995 2 41.00 0.00 43.50 31.50 1.00 1972 9433 14.00 17.00 24.50 33.50 2 57.00 0.00 43.50 13.00 1.00 4101 3893 4.00 30.50 33.50 37.50 2 57.00 0.00 43.50 31.50 1.00 2598 9433 3.50 5.50 17.00 22.00 30.00 35.00 Capacity Width Height 15272 2.00 7.00 4.00 7.00 2.00 7.00 5.00 7.00 5.00 7.00 1.50 7.00 1.50 7.00 4.00 7.00 7.00 7.00 6.50 7.00 11.00 7.00 3.00 7.00 3.00 7.00 9.00 7.00 26.50 7.00 4.00 7.00 2.00 7.00 5.00 7.00 5.00 7.00 DRAGSTRUT AND HOLDDOWN FORCES Level Location [ft] Wall Position on Wall Holddown Force [lbs] Dragstrut X 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 20.00 1 20.00 1 20.00 1 28.00 1 28.00 1 43.50 1 43.50 1 43.50 1 43.50 1 43.50 1 43.50 1 43.50 1 43.50 1 0.00 1 2.00 1 18.00 Y or Opening 0.00 Line 1 Vert. Element 11.00 Line 1 Vert. Element 13.00 Line 1 Vert. Element 23.00 Line 1 Vert. Element 25.00 Line 1 Vert. Element 28.00 Line 1 Vert. Element 33.00 Line 1 Vert. Element 37.00 Line 1 Vert. Element 41.00 Line 1 Vert. Element 46.00 Line 1 Vert. Element 57.00 Line 1 Vert. Element 0.00 Line 2 Vert. Element 10.50 Line 2 Vert. Element 20.00 Line 2 Vert. Element 20.00 Line 3 Vert. Element 31.50 Line 3 Vert. Element 10.50 Line 4 Vert. Element 31.00 Line 4 Vert. Element 32.50 Line 4 Vert. Element 34.00 Line 4 Vert. Element 36.00 Line 4 Vert. Element 41.00 Line 4 Vert. Element 42.50 Line 4 Vert. Element 57.00 Line 4 Vert. Element 0.00 Line A Vert. •Element 0.00 Line A Vert. Element 0.00 Line A Vert. Element Shear Dead Uplift Combined Force[lbs] 703 703 242 242 242 242 703 703 140 461 461 36 242 242 461 461 85 461 461 121 242 242 242 242 703 703 5163 5163 5868 5868 4795 705 705 770 770 770 770 678 678 137 137 541 541 96 541 541 1 137 137 541 541 32 541 541 63 678 678 458 458 458 458 458 458 1 20.00 0.00 Line A Vert. Element 458 458 1 20.00 10.50 Line B Vert. Element 637 637 1 26.50 10.50 Line B Vert. Element 8097 8097 3699 1 30.00 10.50 Line B Vert. Element 8097 8097 646 1 41.00 10.50 Line B Vert. Element 8097 8097 2181 1 43.50 10.50 Line B Vert. Element 8734 8734 1 20.00 20.00 Line C Vert. Element 2365 2365 1 28.00 20.00 Line C Vert. Element 2365 2365 1 0.00 22.00 D -1 Left Wall End 1693 1693 1 10.00 22.00 D -1 Left Wall End 1693 1693 1289 1 13.00 22.00 D -1 Left Wall End 1693 1693 1041 1 20.00 22.00 D -1 Left Wall End 1693 1693 1944 1 0.00 28.00 E -1 Left Wall End 2412 2412 1 14.00 28.00 E -1 Left Wall End 2412 2412 2862 1 28.00 31.00 Line F Vert. Element 2400 2400 1 43.50 31.00 Line F Vert. Element 2400 2400 1 18.00 36.00 G -1 Left Wall End 2372 2372 1227 1 28.00 36.00 G -1 Left Wall End 2372 2372 1056 1 0.00 41.00 H -i Left Wall End 501 501 1 14.00 41.00 H -1 Left Wall End 501 501 242 1 17.00 41.00 H -1 Left Wall End 501 501 106 1 24.50 41.00 H -i Left Wall End 501 501 235 1 33.50 41.00 H -1 Left Wall End 501 501 173 1 43.50 41.00 H -1 Left Wall End 501 501 1 0.00 57.00 Line I Vert. Element 3183 3183 1 3.50 57.00 Line I Vert. Element 660 660 1 4.00 57.00 Line I Vert. Element 3706 3706 885 1 30.50 57.00 Line I Vert. Element 3980 3980 1614 1 33.50 57.00 Line I Vert. Element 2936 2936 950 1 37.50 57.00 Line I Vert. Element 2771 2771 1327 1 43.50 57.00 Line I Vert. Element 3183 3183 2 0.00 0.00 1 -1 Left Wall End 242 242 2 0.00 11.00 1 -1 Left Wall End 242 242 70 2 0.00 13.00 1 -1 Left Wall End 242 242 22 2 0.00 23.00 1 -i Left Wall End 242 242 86 2 0.00 28.00 1 -1 Left Wall End 242 242 33 2 0.00 41.00 1 -1 Left Wall End 242 242 49 2 0.00 46.00 1 -1 Left Wall End 242 242 70 2 0.00 57.00 1 -1 Left Wall End 242 242 2 20.00 0.00 2 -1 Left Wall End 705 705 2 20.00 10.50 2 -1 Left Wall End 1411 1411 2 20.00 20.00 2 -1 Left Wall End 705 705 1145 2 28.00 20.00 3 -1 Left Wall End 770 770 226 2 28.00 31.50 3 -1 Left Wall End 770 770 607 2 43.50 10.50 4 -1 Left Wall End 137 137 2 43.50 31.00 4 -1 Left Wall End 137 137 2 43.50 36.00 4 -1 Left Wall End 137 137 22 2 43.50 57.00 4 -1 Left Wall End 137 137 2 43.50 32.00 4 -2 Left Opening 1 40 2 0.00 0.00 A -1 Left Wall End 458 458 2 6.50 0.00 A -1 Left Wall End 458 458 130 2 13.50 0.00 A -1 Left Wall End 458 458 130 2 20.00 0.00 A -i Left Wall End 458 458 2 20.00 10.50 B =1 Left Wall End 637 637 861 2 43.50 10.50 B -1 Left Wall End 637 637 2 20.00 20.00 C -1 Left Wall End 2365 2365 1088 2 28.00 20.00 C -1 Left Wall End 2365 2365 843 2 28.00 31.00 F -1 Left Wall End 2400 2400 2993 2 43.50 31.00 F -1 Left Wall End 2400 2400 2 0.00 57.00 I -1 Left Wall End 660 660 2 3.50 57.00 I -1 Left Wall End 660 660 80 2 5.50 57.00 I -1 Left Wall End 660 660 40 2 17.00 57.00 I -1 Left Wall End 660 660 222 2 22.00 57.00 I -1 Left Wall End 660 660 77 2 30.00; 57.00 I -1 Left Wall End 660 660 105 2 35.00 57.00 I =1 Left Wall End 660 660 193 2 43.50 57.00 I -1 Left Wall End 660 660 RIGID DIAPHRAGM DESIGN SHEAR RESULTS by SHEARLINE Line Lev Wall Wind Total Cumulative Shear Force Shear Capacity [plf] Response Grp. Dir. FHS V[lbs] Unit V /FHS[plf] Inter Exter Perf Total V /FHS /Tot 1 1 2 S - >N 51.00 4651 81.6 91.2 299.5 1.00 299.5 0.30 2 2 N - >S 45.00 2107 37.0 46.8 299.5 1.00 299.5 0.16 2 1 3 S ->N 10.50 3548 62.2 337.9 585.9 585.9 1.00 1171.8 0.29 2 2 N ->S 20.00 844 14.8 42.2 299.5 1.00 299.5 0.14 3 2 2 N - >S 11.50 484 10.4 42.1 299.5 1.00 299.5 0.14 4 1 2 N ->S 43.50 4295 92.4 98.7 299.5 1.00 299.5 0.33 2 2 N - >S 41.50 1764 37.9 42.5 299.5 1.00 299.5 0.14 A 2 2 W ->E 13.00 1895 94.7 145.7 299.5 1.00 299.5 0.49 B 1 3 W - >E 6.00 5781 132.9 963.5 585.9 585.9 1.00 1171.8 0.82 2 2 W - >E 23.50 3323 76.4 141.4 299.5 1.00 299.5 0.47 C 2 2 W ->E 8.00 1100 25.3 137.5 299.5 1.00 299.5 0.46 D 1 2 W - >E 17.00 3848 88.5 226.4 299.5 1.00 299.5 0.76 E 1 2 W ->E 14.00 3024 69.5 216.0 299.5 1.00 299.5 0.72 F 2 2 W - >E 15.50 2083 47.9 134.4 299.5 1.00 299.5 0.45 G 1 2 W - >E 10.00 2113 48.6 211.3 299.5 1.00 299.5 0.71 H 1 2 W - >E 31.50 6687 153.7 212.3 299.5 1.00 299.5 0.71 I 1 2 W ->E 13.00 2800 64.4 215.4 299.5 1.00 299.5 0.72 2 2 W ->E 31.50 4583 105.4 145.5 299.5 1.00 299.5 0.49 SHEARWALL SEGMENTS Name Lev Type Wall. Dimensions [ft] Full Height Perf Shear [lbs] Opening [ft] Group Location Start End Sheathing Factor Force Capacity Width Height 1 -1 1 I 2 0.00 0.00 57.00 51.00 1.00 4651 15272 Opening 1 23.00 25.00 2.00 7.00 Opening 2 33.00 37.00 4.00 7.00 1 -1 2 I 2 0.00 0.00 57.00 45.00 1.00 2107 13476 Opening 1 11.00 13.00 2.00 7.00 Opening 2 23.00 28.00 5.00 7.00 Opening 3 41.00 46.00 5.00 7.00 2 -1 1 I 3 20.00 0.00 10.50 10.50 1.00 3548 12304 2 -1 2 I 2 20.00 0.00 10.50 10.50 1.00 443 3144 2 -2 2 I 2 20.00 10.50 20.00 9.50 1.00 401 2845 3 -1 2 I 2 28.00 20.00 31.50 11.50 1.00 484 3444 4 -1 1 I 2 43.50 10.50 57.00 43.50 1_.00 4295 13027 Opening 1 32.50 34.00 1.50 7.00 Opening 2 41.00 42.50 1.50 7.00 4 -1 2 I 2 43.50 10.50 31.00 20.50 1.00 871 6139 4 -2 2 I 2 43.50 31.00 57.00 21.00 1.00 893 6289 Opening 1 32.00 36.00 4.00 7.00 A -1 2 I 2 0.00 0.00 20.00 13.00 1.00 1895 3893 Opening 1 6.50 13.50 7.00 7.00 B -1 1 I 3 10.50 20.00 43.50 6.00 1.00 5781 7031 Opening 1 20.00 26.50 6.50 7.00 Opening 2 30.00 41.00 11.00 7.00 B - 2 I 2 10.50 20.00 43.50 23.50 1.00 3323 7037 C - 2 I 2 20.00 20.00 28.00 8.00 1.00 1100 2396 0-1 1 I 2 22.00 0.00 20.00 17.00 1.00 3848 5091 Opening 1 10.00 13.00 3.00 7.00 E -1 1 I 2 28.00 0.00 14.00 14.00 1.00 3024 4192 F -1 2 I 2 31.00 28.00 43.50 15.50 1.00 2083 4642 G -1 1 I 2 36.00 18.00 28.00 10.00 1.00 2113 2995 H - 1 I 2 41.00 0.00 43.50 31.50 1.00 6687 9433 Opening 1 14.00 17.00 3.00 7.00 Opening 2 24.50 33.50 9.00 7.00 I -1 1 I 2 57.00 0.00 43.50 13.00 1.00 2800 3893 Opening 1 4.00 30.50 26.50 7.00 Opening 2 33.50 37.50 4.00 7.00 I -1 2 I 2 57.00 0.00 43.50 31.50 1.00 4583 9433 Opening 1 3.50 5.50 2.00 7.00 Opening 2 17.00 22.00 5.00 7.00 Opening 3 30.00 35.00 5.00 7.00 DRAGSTRUT AND HOLDDOWN FORCES Level Location (ft] Wall Position on Wall Holddown Force [lbs] Dragstrut X Y or Opening Shear Dead Uplift Combined Force[lbs] 1 0.00 0.00 Line 1 Vert. Element 1095 1095 1 0.00 11.00 Line 1 Vert. Element 375 375 1 0.00 13.00 Line 1 Vert. Element 375 375 1 0.00 23.00 Line 1 Vert. Element 1095 1095 221 1 0.00 25.00 Line 1 Vert. Element 720 720 58 1 0.00 28.00 Line 1 Vert. Element 375 375 1 0.00 33.00 Line 1 Vert. Element 720 720 134 1 0.00 37.00 Line 1 Vert. Element 720 720 192 1 0.00 41.00 Line 1 Vert. Element 375 375 1 0.00 46.00 Line 1 Vert. Element 375 375 1 0.00 57.00 Line 1 Vert. Element 1095 1095 1 20.00 0.00 Line 2 Vert. Element 3029 3029 1 20.00 10.50 Line 2 Vert. Element 3366 3366 2895 1 20.00 20.00 Line 2 Vert. Element 338 338 1 28.00 20.00 Line 3 Vert. Element 337 337 1 28.00 31.50 Line 3 Vert. Element 337 337 1 43.50 10.50 Line 4 Vert. Element 1130 1130 1 43.50 31.00 Line 4 Vert. Element 340 340 1 43.50 32.50 Line 4 Vert. Element 790 790 140 1 43.50 34.00 Line 4 Vert. Element 790 790 2 1 43.50 36.00 Line 4 Vert. Element 340 340 1 43.50 41.00 Line 4 Vert. Element 790 790 46 1 43.50 42.50 Line 4 Vert. Element 790 790 92 1 43.50 57.00 Line 4 Vert. Element 1130 1130 1 0.00 0.00 Line A Vert. Element 1166 1166 1 2.00 0.00 Line A Vert. Element 1166 1166 1 18.00 0.00 Line A Vert. Element 1166 1166 1 20.00 0:00 Line A Vert. Element 1166 1166 1 20.00 10.50 Line B Vert. Element 1131 1131 1 26.50 10.50 Line B Vert. Element 7708 7708 3522 1 30.00 10.50 Line B Vert. Element 7708 7708 615 1 41.00 10.50 Line B Vert. Element 7708 7708 2077 1 43.50 10.50 Line B Vert. Element 8840 8840 1 20.00 20.00 Line C Vert. Element 1100 1100 1 28.00 20.00 Line C Vert. Element 1100 1100 1 0.00 22.00 D -1 Left Wall End 1811 1811 1 10.00 22.00 D -1 Left Wall End 1811 1811 1379 1 13.00 22.00 D -1 Left Wall End 1811 1811 1114 1 20.00 22.00 D -1 Left Wall End 1811 1811 2079 1 0.00 28.00 E -1 Left Wall End 1728 1728 1 14.00 28.00 E -1 Left Wall End 1728 1728 2051 1 28.00 31.00 Line F Vert. Element 1075 1075 1 43.50 31.00 Line F Vert. Element 1075 1075 1 18.00 36.00 G -1 Left Wall End 1691 1691 874 1 28.00 36.00 G -1 Left Wall End 1691 1691 753 1 0.00 41.00 H -1 Left Wall End 1698 1698 1 14.00 41.00 H -1 Left Wall End 1698 1698 820 1 17.00 41.00 H -1 Left Wall End 1698 1698 359 1 24.50 41.00 H -i Left Wall End 1698 1698 798 1 33.50 41.00 H -1 Left Wall End 1698 1698 586 1 43.50 41.00 14 -1 Left Wall End 1698 1698 1 0.00 57.00 Line I Vert. Element 2887 2887 1 3.50 57.00 Line I Vert. Element 1164 1164 1 4.00 57.00 Line I Vert. Element 3810 3810 604 1 30.50 57.00 Line I Vert. Element 4293 4293 1102 1 33.50 57.00 Line I Vert. Element 2451 2451 649 1 37.50 57.00 Line I Vert. Element 2160 2160 906 1 43.50 57.00 Line I Vert. Element 2887 2887 2 0.00 0.00 1 -1 Left Wall End 375 375 2 0.00 11.00 1 -1 Left Wall End 375 375 108 2 0.00 13.00 1 -1 Left Wall End 375 375 35 2 0.00 23.00 1 -1 Left Wall End 375 375 133 2 0.00 28.00 1 -1 Left Wall End 375 375 52 2 0.00 41.00 1 -1 Left Wall End 375 375 76 2 0.00 46.00 1 -1 Left Wall End 375 375 108 2 0.00 57.00 1 -1 Left Wall End 375 375 2 20.00 0.00 2 -1 Left Wall End 338 338 2 20.00. 10.50 2 -1 Left Wall End 675 675 2 20.00 20.00 2 =1 Left Wall End 338 338 548 2 28.00 20.00 3 -1 Left Wall End 337 337 99 2 28.00 31.50 3 -1 Left Wall End 337 337 265 2 43.50 10.50 4 -1 Left Wall End 340 340 2 43.50 31.00 4 -1 Left Wall End 340 340 2 43.50 36.00 4 -1 Left Wall End 340 340 53 2 43.50 57.00 4 -1 Left Wall End 340 2 43.50 32.00 4 -2 Left Opening 1 2 0.00 0.00 A -1 Left Wall End 1166 2 6.50 0.00 A -1 Left Wall End 1166 2 13.50 0.00 A -i Left Wall End 1166 2 20.00 0.00 A -1 Left Wall End 1166 2 20.00 10.50 B -1 Left Wall End 1131 2 43.50 10.50 B -i Left Wall End 1131 2 20.00 20.00 Cl = Left Wall End 1100 2 28.00 20.00 C -1 Left Wall End 1100 2 28.00 31.00 F -1 Left Wall End 1075 2 43.50 31.00 F =1 Left Wall End 1075 2 0.00 57.00 I -1 Left Wall End 1164 2 3.50 57.00 I -1 Left Wall End 1164 2 5.50 57.00 I -1 Left Wall End 1164 2 17.00 57.00 I -1 Left Wall End 1164 2 22.00 57.00 I -1 Left Wall End 1164 2 30.00 57.00 I -1 Left Wall End 1164 2 35.00 57.00 I -1 Left Wall End 1164 2 43.50 57.00 I -1 Left Wall End 1164 COMPONENTS AND CLADDING by SHEARLINE Name Level Wall • Sheathing [psf] Group 1 1 2 2 2 2 1 3 2 2 4 1 2 2 2 A 1 1 2 2 B 1 3 2 2 I 1 2 2 2 Force 32.0 32.0 32.0 32.0 32.0 32.0 32.0 32.0 32.0 32.0 61.0 32.0 COMPONENT AND CLADDING DESIGN Cap. Resp 30.0 1.07* 30.0 1.07* 30.0 1.07* 30.0 1.07* 30.0 1.07* 30.0 1.07* 0.0 30.0 1.07* 30.0 1.07* 30.0 1.07* 30.0 2.03* 30.0 1.07* *WARNING - Sheathing design capacity has been exceeded for Flexible Design and Rigid Design Fasteners [lbs] Force Capacity Response End Int End Int 32 26 68 0.47 0.38 32 26 68 0.47 0.38 32 26 68 0.47 0.38 32 26 68 0.47 0.38 32 26 68 0.47 0.38 32 26 68 0.47 0.38 32 26 68 0.47 0.38 32 26 68 0.47 0.38 32 26. 68 0.47 0.38 61 52 68 0.90 0.77 32 26 68 0.47 0.38 SEISMIC DESIGN FLEXIBLE DIAPHRAGM DESIGN 340 98 1166 1166 332 1166 332 1166 1131 1528 1131 1100 506 1100 392 1075 1341 1075 1164 1164 140 1164 70 1164 391 1164 135 1164 186 1164 341 1164 SHEAR RESULTS by SHEARLINE Line Lev Wall Wind Total Cumulative Shear Force Shear Capacity [pif] Response Grp. Dir. FHS V[lbs] Unit V /FHS[plf] Inter Exter Perf Total V /FHS /Tot 1 1 2 51.00 1536 26.9 30.1 213.9 1.00 213.9 0.14 2 2 45.00 932 16.4 20.7 213.9 1.00 213.9 0.10 2 1 3 10.50 1860 32.6 177.1 418.5 418.5 1.00 837.0 0.21 2 2 20.00 880 15.4 44.0 213.9 1.00 213.9 0.21 3 2 2 11.50 327 7.0 28.4 213.9 1.00 213.9 0.13 4 1 2 43.50 1058 22.8 24.3 213.9 1.00 213.9 0.11 2 2 41.50 408 8.8 9.8 213.9 1.00 213.9 0.05 A 2 2 13.00 254 12.7 19.5 213.9 1.00 213.9 0.09 B 1 3 6.00 1276 29.3 212.7 418.5 418.5 1.00 837.0 0.25 2 2 23.50 431 9.9 18.4 213.9 1.00 213.9 0.09 C 2 2 8.00 550 12.6 68.7 213.9 1.00 213.9 0.32 D 1 2 17.00 719 16.5 42.3 213.9 1.00 213.9 0.20 E 1 2 14.00 832 19.1 59.4 213.9 1.00 213.9 0.28 F 2 2 15.50 992 22.8 64.0 213.9 1.00 213.9 0.30 G 1 2 , 10.00 569 13.1 56.9 213.9 1.00 213.9 0.27 H 1 2 31.50 318 7.3 10.1 213.9 1.00 213.9 0.05 I 1 2 13.00 1332 30.6 102.4 213.9 1.00 213.9 0.48 2 2 31.50 912 21.0 29.0 213.9 1.00 213.9 0.14 * WARNING design capacity has been exceeded. SHEARWALL SEGMENTS Name Lev Type Wall Dimensions [ft] Full Height Perf Shear [lbs] Opening [ft] Group Location Start End Sheathing Factor Force Capacity Width Height 1 -1 1 I 2 0.00 0.00 57.00 51.00 1.00 1536 10909 Opening 1 23.00 25.00 2.00 7.00 Opening 2 33.00 37.00 4.00 7.00 1 -1 2 I 2 0.00 0.00 57.00 45.00 1.00 932 9626 Opening 1 11.00 13.00 2.00 7.00 Opening 2 23.00 28.00 5.00 7.00 Opening 3 41.00 46.00 5.00 7.00 2 -1 1 I 3 20.00 0.00 10.50 10.50 1.00 1860 8789 2 =1 2 I 2 20.00 0.00 10.50 10.50 1.00 462 2246 2 -2 2 I 2 20.00 10.50 20.00 9.50 1.00 418 2032 3 -1 2 I 2 28.00 20.00 31.50 11.50 1.00 327 2460 4 -1 1 I 2 43.50 10.50 57.00 43.50 1.00 1058 9305 32.50 34.00 41.00 42.50 2 43.50 10.50 31.00 2 43.50 31.00 57.00 32.00 36.00 2 0.00 0.00 20.00 6.50 13.50 3 10.50 20.00 43.50 20.00 26.50 30.00 41.00 2 10.50 20.00 43.50 23.50 2 20.00 20.00 28.00 8.00 2 22.00 0.00 20.00 17.00 10.00 13.00 2 28.00 0.00 14.00 14.00 2 31.00 28.00 43.50 15.50 2 36.00 18.00 28.00 10.00 2 41.00 0.00 43.50 31.50 14.00 17.00 24.50 33.50 2 57.00 0.00 43.50 4.00 30.50 33.50 37.50 2 57.00 0.00 43.50 Opening 1 Opening 2 4 -1 2 I 4 -2 2 I Opening 1 A -1 2 I Opening 1 B -1 1 I Opening 1 Opening 2 B -1 2 I C -1 2 I D -1 1 I Opening 1 E -1 1 I F -1 2 I G -1 1 I H -1 1 I Opening 1 Opening 2 I -1 1 I Opening 1 Opening 2 I -1 2 I Opening 1 Opening 2 Opening 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3.50 5.50 17.00 22.00 30.00 35.00 0.00 0.00 Line 1 Vert. Element 0.00 11.00 Line 1 Vert. Element 0.00 13.00 Line 1 Vert. Element 0.00 23.00 Line 1 Vert. Element 0.00 25.00 Line 1 Vert. Element 0.00 28.00 Line 1 Vert. Element 0.00 33.00 Line 1 Vert. Element 0.00 37.00 Line 1 Vert. Element 0.00 41.00 Line 1 Vert. Element 0.00 46.00 Line 1 Vert. Element 0.00 57.00 Line 1 Vert. Element 20.00 0.00 Line 2 Vert. Element 20.00 10.50 Line 2 Vert. Element 20.00 20.00 Line 2 Vert. Element 28.00 20.00 Line 3 Vert. Element 28.00 31.50 Line 3 Vert. Element 43.50 10.50 Line 4 Vert. Element 43.50 31.00 Line 4 Vert. Element 43.50 32.50 Line 4 Vert. Element 43.50 34.00 Line 4 Vert. Element 43.50 36.00 Line 4 Vert. Element 43.50 41.00 Line 4 Vert. Element 43.50 42.50 Line 4 Vert. - Element 43.50 57.00 Line 4 Vert. Element 0.00 0.00 Line A Vert. Element 20.50 1.00 21.00 1.00 13.00 1.00 6.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 13.00 1.00 31.50 1.00 166 166 407 241 166 241 241 166 166 407 1769 2121 352 227 227 273 79 195 195 79 195 195 273 156 201 4385 206 4492 254 2781 1276 5022 431 550 719 832 992 569 318 5027 1711 3636 2995 3315 2139 6738 1332 2781 912 6738 DRAGSTRUT AND HOLDDOWN FORCES Level Location [ft] Wall Position on Wall Holddown Force [lbs] Dragstrut X Y or Opening Shear Dead Uplift Combined Force[lbs] 407 407 166 166 407 241 166 241 241 166 166 407 1769 2121 352 227 227 273 79 195 195 79 195 195 273 156 1.50 7.00 1.50 7.00 4.00 7.00 7.00 7.00 6.50 7.00 11.00 7.00 3.00 7.00 3.00 7.00 9.00 7.00 26.50 7.00 4.00 7.00 2.00 7.00 5.00 7.00 5.00 7.00 73 19 44 63 1517 35 0 11 23 1 2.00 0.00 Line A Vert. Element 156 156 1 18.00 0.00 Line A Vert. Element 156 156 1 20.00 0.00 Line A Vert. Element 156 156 1 20.00 10.50 Line B Vert. Element 147 147 1 26.50 10.50 Line B Vert. Element 1702 1702 778 1 30.00 10.50 Line B Vert. Element 1702 1702 136 1 41.00 10.50 Line B Vert. Element 1702 1702 459 1 43.50 10.50 Line B Vert. Element 1849 1849 1 20.00 20.00 Line C Vert. Element 550 550 1 28.00 20.00 Line C Vert. Element 550 550 1 0.00 22.00 D -1 Left Wall End 338 338 1 10.00 22.00 D -1 Left Wall End 338 338 258 1 13.00 22.00 D -1 Left Wall End 338 338 208 1 20.00 22.00 D -1 Left Wall End 338 338 388 1 0.00 28.00 E -1 Left Wall End 475 475 1 14.00 28.00 E -1 Left Wall End 475 475 564 1 28.00 31.00 Line F Vert. Element 512 512 1 43.50 31.00 Line F Vert. Element 512 512 1 18.00 36.00 G -1 Left Wall End 455 455 235 1 28.00 36.00 G -1 Left Wall End 455 455 203 1 0.00 41.00 H -1 Left Wall End 81 81 1 14.00 41.00 H -1 Left Wall End 81 81 39 1 17.00 41.00 H -1 Left Wall End 81 81 17 1 24.50 41.00 H -1 Left Wall End 81 81 38 1 33.50 '41•.00 H -i Left Wall End 81 81 28 1 43.50 41.00 H -1 Left Wall End 81 81 1 0.00 57.00 Line I Vert. Element 1051 1051 1 3.50 57.00 Line I Vert. Element 232 232 1 4.00 57.00 Line I Vert. Element 1235 1235 287 1 30.50 57.00 Line I Vert. Element 1331 1331 524 1 33.50 57.00 Line I Vert. Element 964 964 308 1 37.50 57.00 Line I Vert. Element 906 906 431 1 43.50 57.00 Line I Vert. Element 1051 1051 2 0.00 0.00 1 -1 Left Opening 3 166 166 2 0.00 11.00 1 -1 Left Opening 3 166 166 48 2 0.00 13.00 1 -1 Left Opening 3 166 166 15 2 0.00 23.00 1 -1 Left Opening 3 166 166 59 2 0.00 28.00 1 -1 Left Opening 3 166 166 23 2 0.00 41.00 1 -1 Left Opening 3 166 166 34 2 0.00 46.00 1 -1 Left Opening 3 166 166 48 2 0.00 57.00 1 -1 Left Opening 3 166 166 2 20.00 0.00 2 -1 Left Wall End 352 352 2 20.00 10.50 2 -1 Left Wall End 704 704 2 20.00 20.00 2 -1 Left Wall End 352 352 571 2 28.00 20.00 3-1 Left Wall End 227 227 67 2 28.00 31.50 3 -1 Left Wall End 227 227 179 2 43.50 10.50 4 -1 Left Wall End 79 79 2 43.50 31.00 4 -1 Left Wall End 79 79 2 43.50 36.00 4 -1 Left Wall End 79 79 12 2 43.50 57.00 4 -1 Left Wall End 79 79 2 43.50 32.00 4 -2 Left Opening 1 23 2 0.00 '0.00 A -1 Left Opening 1 156 156 2 6.50 0.00 A -1 Left Opening 1 156 156 44 2 13.50 0.00 A =l Left Opening 1 156 156 44 2 20.00 0.00 A -1 Left Opening 1 156 156 2 20.00 10.50 B -1 Left Wall End 147 147 198 2 43.50 10.50 B -1 Left Wall End 147 147 2 20.00 20.00 C -1 Left Wall End 550 550 253 2 28.00 20.00 C -1 Left Wall End 550 550 196 2 28.00 31.00 F -1 Left Wall End 512 512 639 2 43.50 31.00 F -1 Left Wall End 512 512 2 0.00 57.00 I -1 Left Opening 3 232 232 2 3.50 57.00 I -1 Left Opening 3 232 232 28 2 5.50 57.00 I -1 Left Opening 3 232 232 14 2 17.00 57.00 I -i Left Opening 3 232 232 78 2 22.00 57.00 I -1 Left Opening 3 232 232 27 2 30.00 57.00 I -1 Left Opening 3 232 232 37 2 35.00 57.00 I -1 Left Opening 3 232 232 68 2 43.50 57.00 I -1 Left .Opening 3 232 232 SHEAR RESULTS Line Lev Wall Grp. 1 1 2 2 2 2 1 3 2 2 3 2 2 4 1 2 2 2 A 2 2 B 1 3 2 2 C 2 2 D 1 2 E 1 2 F 2 2 G 1 2 H 1 2 I 1 2 * WARNING by SHEARLINE Wind Total Dir. FHS 51.00 45.00 10.50 20.00 11.50 43.50 41.50 13.00 6.00 23.50 8.00 17.00 14.00 15.50 10.00 31.50 2 13.00 2 31.50 design capacity SHEARWALL SEGMENTS Name Lev Type Wall Group 1 -1 1 I 2 Opening 1 Opening 2 1 -1 2 I Opening 1 Opening 2 Opening 3 2 -1 1 I 3 20.00 2 -1 2 I 2 20.00 2 -2 2 I 2 20.00 3 -1 2 I 2 28.00 4 -1 1 I 2 43.50 Opening 1 Opening 2 4 -1 2 I 2 43.50 4 -2 2 I 2 43.50 Opening 1 A -1 2 I Opening 1 B -1 1 I 3 10.50 Opening 1 Opening 2 B -1 2 I 2 10.50 C -1 2 I 2 20.00 D -1 1 I 2 22.00 Opening 1 E -1 1 I F -1 2 I G -1 1 I H -1 1 I Opening 1 Opening 2 I -1 1 I Opening 1 Opening 2 I -1 2 I Opening 1 Opening 2 Opening 3 17.00 22.00 30.00 35.00 RIGID DIAPHRAGM DESIGN Cumulative Shear Force V[lbs] Unit V /FHS[plf] 1910 33.5 37.4 1149 20.2 25.5 1350 23.7 128.6 437 7.7 21.8 244 5.3 21.3 1485 31.9 34.1 849 18.3 20.5 459 23.0 35.3 1192 27.4 198.7 822 18.9 35.0 277 6.4 34.6 821 18.9 48.3 658 15.1 47.0 536 12.3 34.6 473 10.9 47.3 1522 35.0 48.3 671 15.4 51.7 1238 28.5 39.3 has been exceeded. Shear Capacity [plf] Inter Exter Perf Total 213.9 1.00 213.9 213.9 1.00 213.9 418.5 418.5 1.00 837.0 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 418.5 418.5 1.00 837.0 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 213.9 1.00 213.9 Dimensions [ft] Full Height Perf Location Start End Sheathing Factor 0.00 0.00 57.00 51.00 1.00 23.00 25.00 33.00 37.00 2 0.00 0.00 57.00 45.00 1.00 1149 9626 11.00 13.00 23.00 28.00 41.00 46.00 0.00 10.50 10.50 0.00 10.50 10.50 10.50 20.00 9.50 20.00 31.50 11.50 10.50 57.00 43.50 32.50 34.00 41.00 42.50 10.50 31.00 20.50 1.00 31.00 57.00 21.00 1.00 32.00 36.00 2 0.00 0.00 20.00 13.00 1.00 459 2781 6.50 13.50 20.00 43.50 6.00 1.00 1192 5022 20.00 26.50 30.00 41.00 20.00 43.50 23.50 20.00 28.00 8.00 0.00 20.00 17.00 10.00 13.00 2 28.00 0.00 14.00 14.00 2 31.00 28.00 43.50 15.50 2 36.00 18.00 28.00 10.00 2 41.00 0.00 43.50 31.50 14.00 17.00 24.50 33.50 2 57.00 0.00 43.50 13.00 1.00 671 2781 4.00 30.50 33.50 37.50 2 57.00 0.00 43.50 31.50 1.00 1238 6738 3.50 5.50 1.. 00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Shear [lbs] Opening [ft] Force Capacity Width Height 1910 10909 1350 229 208 244 1485 8789 2246 2032 2460 9305 420 4385 430 4492 822 277 821 658 536 473 1522 5027 1711 3636 2995 3315 2139 6738 Response V /FHS /Tot 0.18 0.12 0.15 0.10 0.10 0.16 0.10 0.17 0.24 0.16 0.16 0.23 0.22 0.16 0.22 0.23 0.24 0.18 2.00 7.00 4.00 7.00 2.00 7.00 5.00 7.00 5.00 7.00 1.50 7.00 1.50 7.00 4.00 7.00 7.00 7.00 6.50 7.00 11.00 7.00 3.00 7.00 3.00 7.00 9.00 7.00 26.50 7.00 4.00 7.00 2.00 7.00 5.00 7.00 5.00 7.00 DRAGSTRUT AND HOLDDOWN FORCES Level Location [ft] Wall Position on Wall Holddown Force [lbs] Dragstrut X Y or Opening Shear Dead Uplift Combined Force[lbs] 1 0.00 0.00 Line 1 Vert. Element 504 504 1 0.00 11.00 Line 1 Vert. Element 204 20 1 0.00 13.00 Line 1 Vert. Element 204 204 1 0.00 23.00 Line 1 Vert. Element 504 504 91 1 0.00 25.00 Line 1 Vert. Element 300 300 24 1 0.00 28.00 Line 1 Vert. Element 204 204 1 0.00 33.00 Line 1 Vert. Element 300 300 55 1 0.00 37.00 Line 1 Vert. Element 300 300 79 1 0.00 41.00 Line 1 Vert. Element 204 204 1 0.00 46.00 Line 1 Vert. Element 204 204 1 0.00 57.00 Line 1 Vert. Element 504 504 1 20.00 0.00 Line 2 Vert. Element 1203 1203 1 20.00 10.50 Line 2 Vert. Element 1378 1378 1101 1 20.00 20.00 Line 2 Vert. Element 175 175 1 28.00 20.00 Line 3 Vert. Element 170 170 1 28.00 31.50 Line 3 Vert. Element 170 170 1 43.50 10.50 Line 4 Vert. Element 437 437 1 43.50 31.00 Line 4 Vert. Element 164 164 1 43.50 32.50 Line 4 Vert. Element 273 273 48 1 43.50 34.00 Line 4 Vert. Element 273 273 1 1 43.50 36.00 Line 4 Vert. Element 164 164 1 43.50 41.00 Line 4 Vert. Element 273 273 16 1 43.50 42.50 Line 4 Vert. Element 273 273 32 1 43.50 57 :00 Line 4 Vert. Element 437 437 1 0.00 0.00 Line A Vert. Element 283 283 1 2.00 0.00 Line A Vert. Element 283 283 1 18.00 0.00 Line A Vert. Element 283 283 1 20.00 0.00 Line A Vert. Element 283 283 1 20.00 10.50 Line B Vert. Element 280 280 1 26.50 10.50 Line B Vert. Element 1589 1589 726 1 30.00 10.50 Line B Vert. Element 1589 1589 127 1 41.00 10.50 Line B Vert. Element 1589 1589 428 1 43.50 10.50 Line B Vert. Element 1869 1869 1 20.00 20.00 Line C Vert. Element 277 277 1 28.00 20.00 Line C Vert. Element 277 277 1 0.00 22.00 D -1 Left Wall End 386., 386 1 10.00 22.00 D -1 Left Wall End 386 386 294 1 13.00 22.00 D -1 Left Wall End 386 386 238 1 20.00 22.00 D -1 Left Wall End 386 386 444 1 0.00 28.00 E -1 Left Wall End 376 376 1 14.00 28.00 E -1 Left Wall End 376 376 446 1 28.00 31.00 Line F Vert. Element 277 277 1 43.50 31.00 Line F Vert. Element 277 277 1 18.00 36.00 G =1 Left Wall End 378 378 196 1 28.00 36.00 G -1 Left Wall End 378 378 169 1 0.00 41.00 H -1 Left Wall End 387 387 1 14.00 41.00 H -1 Left Wall End 387 387 187 1 17.00 41.00 H -1 Left Wall End 387 387 82 1 24.50 41.00 H -1 Left Wall End 387 387 182 1 33.50 41.00 H -1 Left Wall End 387 387 133 1 43.50 41.00 H -1 Left Wall End 387 387 1 0.00 57.00 Line I Vert. Element 728 728 1 3.50 57.00 Line I Vert. Element 314 314 1 4.00 57.00 Line I Vert. Element 977 977 145 1 30.50 57.00 Line I Vert. Element 1107 1107 264 1 33.50 57.00 Line I Vert. Element 610 610 156 1 37.50 57.00 Line I Vert. Element 531 531 217 1 43.50 57.00 Line I Vert. Element 728 728 2 0.00 0.00 1 -1 Left Opening 3 204 204 2 0.00 11.00 1 -1 Left Opening 3 204 204 59 2 0.00 13.00 1 -1 Left Opening 3 204 204 19 2 0.00 23.00 1 -1 Left Opening 3 204 204 73 2 0.00 28.00 1 -1 Left Opening 3 204 204 28 2 0.00 41.00 1 -1 Left Opening 3 204 204 42 2 0.00 46.00 1 -1 Left Opening 3 204 204 59 2 0.00 57.00 1 -1 Left Opening 3 204 204 2 20.00 0.00 2 -1 Left Wall End 175 175 2 20.00 10.50 2 -1 Left Wall End 350 350 2 20.00 20.00 2 -1 Left Wall End 175 175 284 2 28.00 20.00 3 -1 Left Wall End 170 170 50 2 28.00 31.50 3 -1 Left Wall End 170 2 43.50 10.50 4 -1 Left Wall End 164 2 43.50 31.00 4 -1 Left Wall End 164 2 43.50 36.00 4 -1 Left Wall End 164 2 43.50 57.00 4 -1 Left Wall End 164 2 43.50 32.00 4 -2 Left Opening 1 2 0.00 0.00 A -1 Left Opening 1 283 2 6.50 0.00 A -1 Left Opening 1 283 2 13.50 0.00 A -1 Left Opening 1 283 2 20.00 0.00 A -1 Left Opening 1 283 2 20.00 10.50 B -1 Left Wall End 280 2 43.50 10.50 B =1 Left Wall End 280 2 20.00 20.00 C -1 Left Wall End 277 2 28.00 20.00 C -1 Left Wall End 277 2 28.00 31.00 F -1 Left Wall End 277 2 43.50 31.00 F -1 Left Wall End 277 2 0.00 57.00 I -1 Left Opening 3 314 2 3.50 57.00 I -1 Left Opening 3 314 2 5.50 57.00 I -1 Left Opening 3 314 2 17.00 57.00 I -1 Left Opening 3 314 2 22.00 57.00 I =1 Left Opening 3 314 2 30.00 57.00 I -1 Left Opening 3 314 2 35.00 57.00 I -1 Left Opening 3 314 2 43.50 57.00 I -1 Left Opening 3 314 170 134 164 164 164 26 164 47 283 283 80 283 80 283 280 378 280 277 127 277 99 277 345 277 314 314 38 314 19 314 106 314 37 314 50 314 92 314 es 7 7c - 44 5 (?) ci) LIN (41.) t?) es3 ti /0 17 3 VI) (/b) r 4 j V Tukwila City Bulletin W.S.E.C. Section 502.1.6 Moisture Control ftf PERMIT NO. 201 /l� Project 1 t� A vapor retarder is a layer of material placed over the warm side of insulation to limit the transport of water and water vapor movement through exterior walls, ceilings and floors. To meet energy code requirements, vapor retarders need to be rated at not more than 1.0 perm dry cup or less. Components of a house that require a vapor retarder are: • Floors - Floors between heated and unheated spaces are required to have an installed vapor retarder. Floor decking of 3 inch tongue and groove exterior plywood and exterior grade O.S.B. both meet the vapor retarder requirements. • Walls - Walls separating heated from unheated space are required to have an installed vapor retarder on the side (warm side in winter). • Ceilings - Ceilings where there is an average of less than 12 inches of ventilated area above the insulation, an installed vapor retarder is required. Construction documents shall specify the proposed method for providing a vapor retarder in each of the above building components. *Please check which type of insulation method will be used for the project and return this bulletin with the permit application. Recognized method are as follows: ❑ Kraft or Foil Faced Insulation: Facing material must be stapled directly to the face of the studs. (i.e. to 2x edges not the side of studs) 4 -Mil or thicker Polyethylene or craft faced material: Polyethylene of craft faced material shall be stapled to the framing, with seams overlapped 6- inches and taped. Electrical boxes and other penetrations to be tight fitted and sealed around openings. ❑ Vapor retarding paint: Vapor retarding paint listed to provide transmissivity of not more than 1.0 perm dry cup rating. (See Affidavit attached to bulletin) If vapor retarding paint is specified as a vapor retarder for walls and ceilings, the following conditions shall be required for the builder: Complete Contractor's affidavit and submit with building permit application. (A form is included with the permit packet) A red stamped copy of the affidavit shall remain with the permit at the job site and shall be kept available for building final inspection. Tukwila doc. A -001 Created on 10/19/2007 Revised FILE COPY RETURN THIS FORM WHEN COMPLETED RECEIVED CITY OF TUKWILA NOV 0 0 2007 PERMIT CENTER CORRECTION LTR# f . 3 DATE: CONTACT: RE: ADDRESS: ZONING: PLANNING DIVISION COMMENTS November 8, 2007 Gary Singh D07 -384 46XX S 148 Street LDR The Planning Division of DCD has reviewed the above permit application. The application as submitted is approved subject to the following condition(s): 1. Please note that you are proceeding at your own risk by obtaining a building permit prior to any future short plat application you may be considering. The City is making no warranties and is providing no guarantees that a short plat may be approved at a future date. The home approved under this building permit will be required to comply with all basic development standards in place at the time of the filing of a complete short plat application. S„ 1,ec , .64.v stl,,,,, rsr„Li da , r ks cer, Vac h � K 11 C31'1 Az Pdr24-t74) am-L. L:-it‘liC°. 1 'ct-,et- ce,),e5 -JO ;A.- ` / I n a 1/44ca:ajc Y '" °'tom v, i w;11 b 1- _• w �N`''.� �,� a <^ 1' II � ' " ten s `,' �"" , .� X11 Vz- :: A '?\ .-,,,_ NAJIN vPir AA, \ CYLe, 1,--4-- a- C aA• s Sb � <1 t u kw t LP . /314a-:-.! re-Y)I-4 P ►RECTION 1# 1 RECEIVED CITY OF TUKWILA NOV 0 6 2007 PERMIT CENTER sikc itr)-:f November 2, 2007 Gary Singh 4224 S 148 St Tukwila WA 98168 ifer "arshall 't Technician encl File No. D07 -384 City of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number D07 -384 Sidhu Homes — 46xx S 148 St Dear Mr. Singh, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time the Building, Fire, and Planning Departments have no comments. Planning Department: Brandon Miles, at 206 431 -3684, if you have question regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, P:\Permit Center \Correction Letters\2007\D07 -384 Correction Ur #1.DOC jem Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: CONTACT: RE: ADDRESS: ZONING: October 12, 2007 Gary Singh D07 -384 46XX S. 148 St. LDR PLANNING DIVISION COMMENTS The Planning Division of DCD has reviewed the above permit application. The application as submitted cannot be approved. 1. Aerial photos show structures on the subject property. Clarify the use of the property, if existing structures exists on the property they need to be shown on the site plan. 2. The development standards being utilized are for a lot that has an area of 30,000 square feet. If you intend on doing a short plat please note that at the time of a plat the proposed home will have to comply with the development standards for the area of the proposed home. You are proceeding at your own risk by proceeding ahead with a building permit before a short plat is approved. Construction of the home may impact the development of your short plat. October 8, 2007 City of Tukwila Attn: Building Plans Examiner Dear Sir: Bruce S. MacVeigh, P.E. Civil Engineer /Small Site Geotechnical 14245 59 Ave. S. Tukwila, WA 98168 Office: (206) 242 -7665 Fax: Same Subject: Re -Issue of Residential House Plans and Calculations, Plan #DD07- 4237 -P4 Submitted with this letter are residential house plans and calculations previously submitted and approved by the City of Tukwila. The plans have been re- drafted and improved from the previous use, which was under Building Permit #D06 -100. Having reviewed the improved plans, it was noted that some very small changes in building layout have been made. Comparison with the previous plans indicates that these changes do not substantially affect the previous calculations. The shear walls and hold downs for the current submittal are unchanged from the earlier plan. While we realize the current submittal requires its own attention and review, it is hoped that the above information is helpful. Should questions arise, please feel free to contact this office. Sincerely, e . MacVeigh, Civil Engineer garysinghhs01 /0758 RECEIVED CITY OF TUKWILA OCT 1 0 2007 PEHMIT CENTER QUANTITY IN CUBIC YARDS RATE Up to 50 CY Free 51 -100 $23.50 101 -1,000 $37.00 1,001 - 10,000 $49.25 10,001 - 100,000 $49.25 for 1 10,000, PLUS $24.50 for each additional 10,000 or fraction thereof. 100,001 - 200,000 $269.75 for l 100,000, PLUS $13.25 for each additional 10,000 or fraction thereof. 200,001 or more $402.25 for 1 200,000, PLUS $7.25 for each additional 10,000 or fraction thereof. BULLETIN A2 TYPE C PERMIT FEE ESTIMATE PLAN REVIEW AND APPROVAL FEES DUE WITH APPLICATION PW may adjust estimated fees PROJECT NAME G M (S F,) PERMIT # 44._ S. l ¢BfiS or-) If you do not pro a contractor bids or an engineer's estimate with your permit application, Public Works will review the cost estimates for reasonableness and may adjust estimates. 1. APPLICATION BASE FEE 2. Enter total construction cost for each improvement category: o� Mobilization Erosion prevention - Water /Sewer /Surface Water 5dv 2So !sow • - Road/Parking/Access q $ co. 42 A. Total Improvements 3. Calculate improvement -based fees: B. 2.5% of first $100,000 of A. C. 2.0% of amount over $100,000, but less than $200,000 of A. D. 1.5% of amount over $200,000 of A. 4. TOTAL PLAN REVIEW FEE (B +C +D) 5. Enter total excavation volume 5o cubic yards Enter total fill volume .So cubic yards Use the following table to estimate the grading plan review and permit fee. ater of the excavation and fill volumes. GRADING Plan Review and Permit Fees Approved 09.25.02 Last Revised Jan. 2006 1 $250 (1) Ifb 6.7 so $ /68 S (4) TOTAL PLAN REVIEW AND APPROVAL FEE DUE WITH PERMIT APPLICA'JON (1 +4 +5) $ The Plan Review and Approval fees cover TWO reviews: 1) the first review associated with the submission of the application/plan and 2) a follow -up review associated with a correction letter. Each additional review, which is attributable to the Applicant's action or inaction shall be charged 25% of the Total Plan Review Fee. CITY OF /ILA OCT 10 2007 IT CENTER ( wT V1 QUANTITY IN CUBIC YARDS RATE 50 or less $23.50 51 —100 $37.00 101 — 1,000 $37.00 for 1 100 CY plus $17.50 for each additional 100 or fraction thereof. 1,001 — 10,000 $194.50 for 1 1000 CY plus $14.50 for each additional 1,000 or fraction thereof. 10,001 — 100,000 $325.00 for the 1st 10,000 CY plus $66.00 for each additional 10,000 or fraction thereof 100,001 or more $919.00 for 1 100,000 CY plus $36.50 for each additional 10,000 or fraction thereof. Approx. Remaining Years Pavement Overlay and Repair Rate (per SF of lane width) 20 -15 (100 %) $10.00 15 -10 (75 %) $7.50 10 -7 (50 %) $5.00 7 -5 (33 %) $3.30 5 -2 (25 %) $2.50 2 -1 (10 %) $1.00 0 -1 $0.00 Approved 09.25.02 Last Revised Jan. 2006 BULLETIN A2 TYPE C PERMIT FEE ESTIMATE PLAN REVIEW AND APPROVAL FEES DUE WITH APPLICATION PW may adjust estimated fees 6. Permit Issuance/Inspection Fee (B +C +D) 7. Pavement Mitigation Fee The pavement mitigation fee compensates the City for the reduced life span due to removal of roadway surfaces. The fee is based on the total square feet of impacted pavement per lane and on the condition of the existing pavement. Use the following table and Bulletin 1B to estimate the p 8. GRADING Permit Review Fee Grading Permit Fees are calculated using the following table. Use the greater of the excavation and fill volumes from Item 5. 2 $ (6) (7) $ Z 3 s (8) WATER METER FEE Permanent and Water Only Meters Size (inches) Installation Cascade Water Alliance RCFC 01.01.2007 — 12.31.2007 Total Fee 0.75 $600 $5297 $5897 1 $1100 $13,242.50 $14,342.50 1.5 $2400 $26,485 $28,885 2 $2800 $42,376 $45,176 3 $4400 $84,752 $89,152 4 $7800 $132,425 $148,015 6 $12500 $264,850 $277,350 BULLETIN A2 TYPE C PERMIT FEE ESTIMATE PLAN REVIEW AND APPROVAL FEES DUE WITH APPLICATION PW may adjust estimated fees 9. TOTAL OTHER PERMITS A. Water Meter — Deduct ($25) B. Flood Control Zone ($50) C. Water Meter — Permanent* D. Water Meter — Water only* E. Water Meter — Temporary* * Refer to the Water Meter Fees in Bulletin Al Total A through E $ (9) 10. ADDITIONAL FEES A. Allentown Water (Ordinance 1777) $ B. Allentown Sewer (Ordinance 1777) $ C. Ryan Hill Water (Ordinance 1777) $ D. Special Connection (TMC Title 14) $ E. Duwamish $ F. Transportation Mitigation $ CO /3 98 G. Other Fees / $ 300 % Si 7-� G CN�X Total A through G $ S i3 (10) DUE WHEN PERMIT IS ISSUED (6 +7 +8 +9 +10) $ '5 - ESTIMATED TOTAL PERMIT ISSUANCE AND INSPECTION FEE This fee includes two inspection visits per required inspection. Additional inspections (visits) attributable to the Permittee's action or inaction shall be charged $47.00 per inspection. Approved 09.25.02 Last Revised Jan. 2006 0.75" 2.5" $300 $1,000 Temporary Meter 3 ACTIVITY NUMBER: D07 -384 DATE: 11 -06 -07 PROJECT NAME: SIDHU HOMES SITE ADDRESS: 46XX S 148 ST Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued Original Plan Submittal DEPARTMENTS: , !lj 4 q Buil��ing'd�vi n' aj Public Work 11+01 D= rRMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-08-07 Complete Comments: PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: swii PERMIT COORD COPY Planning Permit Coordinator Not Applicable ❑ No further Review Required DATE: 1 'vision n DUE DATE: 12-06-07 DATE: Approved ❑ Approved with Conditions U Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D07 -384 DATE: 10.10 -07 PROJECT NAME: SIDHU HOMES SITE ADDRESS: 46XX S 148 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: , . & 1! Bui r ing Division Public Works 41006 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: PLAN REVIEW /ROUTING SLIP -14-61 Structural Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 ERMIT COORD COPY ; 4I1 Avu o n rd �nrfih g d f � Fire Prevention Pl LI IVlslon ❑ Permit Coordinator ❑ DUE DATE: 10-11 -07 Not Applicable ❑ No further Review Required DATE: DUE DATE: 11-08-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) r( Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 1110-1n- Departments issued corrections: Bldg ❑ Fire ❑ Ping PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fay etc. Date: 1 /- °5 - 2 Plan Check/Permit Number: D / - 3 Yy nse omplet r # Response to Correction Letter # I Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: S?/1-5 /2-e 51 d e C t Project Address: / X X 5 1v e SI. `TU/c ' / c A (.....) ,a) gl6 g Contact Person: °4 i Si' L')/t- Phone Number: 2.L— `I e-ick cry Summary of Revision: ., Sheet Number(s): Z Received at the City of Tukwila Permit Center b Entered in Permits Plus on a *kg' v T lapplications\fomu- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: "Cloud" or highlight all areas of revision including date of r ision I !Ai '1p !,_ RECENEp CITY OF T( OR NOV 06 2007' Steve Lancaster, Director G! Steven M Mullet, Mayor Part A: (To Be Completed by Applicant) Purpose of Certificate: a Building Permit ❑ Preliminary Plat or PUD ❑ Other ❑ Short Subdivision ❑ Rezone Proposed Use: . Residential Single Family ❑ Residential Multi - Family ❑ Commercial ❑ Other Applicants Name: S / 0/it/ ON-t c.S, . I ►^c . Phone: 20 - k `A —k`l °C) Property Address or Approximate Location: 4, XX Tax Lot Number: 001/2_000 / 3 S• / sl. Legal Description(Attach Map and Legal Description if necessary): J b_oLz L0-f-3 5 Part B: (To Be Completed by Sewer Agency) /r 1. Ei a. Sewer Service will be provided by side sewer connection only to an existing 6 size sewer L feet from the site and the sewer system has the capacity to serve the proposed use. OR ❑ b. Sewer service will require an improvement to the sewer system of: ❑ (1) feet of sewer trunk or lateral to reach the site; and /or ❑ (2) the construction of a collection system on the site; and /or ❑ (3) other (describe): 2. (Must be completed if 1.b above is checked) . ❑ a. The sewer system improvement is in conformance with a County approved sewer comprehensive plan, OR ❑ b. The sewer system improvement will require a sewer comprehensive plan amendment. 3. IIK. The proposed project is within the corporate limits of the District, or has been granted Boundary Review Board approval for extension of service outside the District, OR ❑ b. Annexation or BRB approval will be necessary to provide service. 4. Service is subject to the following: PERMIT: $ /00 , CO a. District Connection Charges due prior to connection: GFC: $ &50 SFC: $ UNIT: $ Treatment Capacity Charge: $ TOTAL: $ 950 , 0 fc (Subject to Change on January 1st) b. Easements: ❑ Required ❑ May be Required c. Other: RFCFIVFD CITY OF TUKWILA Off 1p "n7 I hereb from Residentia -C 1(I Title 14816 M' Road South P.O. Bo)6.o..9550 Tukwila, WA 98168 Phone: (206) 242 -3236 Fax: (206) 242 -1527 CITY OF BURIEN CERTIFICATE OF SEWER AVAILABILITY /NON - AVAILABILITY Commercial: $100 g Certificate of Sewer Availability OR ❑ Certificate of Sewer Non - Availability PEHMII. CENTER at the above sewer agency information is true. This certification shall be valid for one year ature. lo• /O.O Date ATTACHMENT TO VAL VUE SEWER DISTRICT CERTIFICATE OF SEWER AVAILABILITY/NON - AVAILABILITY The following terms and conditions apply to the attached Val Vue Sewer District ( "District ") Certificate of Sewer Availability/Non- Availability ( "Certificate "). 1. This Certificate is valid only for the real property referenced herein ( "Property"), which is in the District's service area, for the sole purpose of submission to the King County Department of Development and Environmental Services, King County Department of Public Health, City of Seattle, City of Tukwila, City of Burien and/or City of SeaTac. This Certificate is between the District and the applicant only, and no third person or party shall have any rights hereunder whether by agency, third -party beneficiary principles or otherwise. 2. This Certificate creates no contractual relationship between the District and the applicant and its successors and assigns, and does not constitute and may not be relied upon as the District's guarantee that sewer service will be available at the time the applicant may apply to the District for such service. 3. As of the date of the District's signature on this Certificate, the District represents that sewer service is available to the Property through sewer systems that exist or that may be extended by the applicant. The District makes no other representations, express or implied, including without limitation that the applicant will be able to obtain the necessary permits, approvals and authorizations from King County, City of Seattle, City of Tukwila, City of Burien, City of SeaTac or any other governmental agency before the applicant can utilize the sewer service which is the subject of this Certificate. 4. If the District or the applicant must extend the District's sewer system to provide sewer service to the Property, the District or applicant may be required to obtain from the appropriate governmental agency the necessary permits, approvals and authorizations. In addition, the governmental agency may establish requirements that must be satisfied as a condition of granting any such permits, approvals or authorizations, which may make impractical or impossible the provision of sewer services to the Property. 5. Application for and possible provision of sewer service to the Property shall be subject to and conditioned upon availability of sewer service to the Property at the time of such application, and compliance with federal, state, local and District laws, ordinances, policies, and/or regulations in effect at the time of such application. I acknowledge that I have received the Certificate ofSewer Availability/Non-Availability and this Attachment, and fully understand the terms and cond e s herein. Applicant's gn. Date totio0' r,.. n k A .f . F A 4 2 OwrjetirlfontlatlQrt, .�. � ..�f,_ � { �� � � `. }.�� f 3 , , ' i�^Y � ' r / �enlifCvtif�tt.l?ea'��h � . �'��.��F ����, �-,�� u� ���,�- Name: , S 'DR R v u oN Sr. s , Luc . Name: 54 ,,, , ,,, z. Address: i ' ay S. I y $ sk- . Address: Phone: 24 2 4 1 1_0 D p Phone: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Permit Center /Building Division: 206 -431 -3670 Public Works Department: 206 - 433 -0179 Planning Division: 206 -431 -3670 etet3bY ppii. Site address (attach map and legal description showing hydrant location and size of main): Cv x x Se l y�N , S - �. This certificate is for the purposes of: I21 Residential Building Permit ❑ Commercial/Industrial Building Permit Estimated number of service connections and water meter size(s): Vehicular distance from nearest hydrant to the closest point t�f VYYMM w tni . 1 25 Area is served by (Water Utility District): / �� CCIt�f Owner /Agent Signature i` Part B: To be compieted.by water uti lity d strict 1. The proposed project is within T4 IA w I I hereby certify that the above information is true and correct. Agency/Phone Zoe - 2 j z-- 95 7 K:rc CERTIFICATE OF WATER AVAILABILITY Required only if outside City of Tukwila water district PERMIT NO.: Preliminary Plat ❑ Short Subdivision Rezone ❑ Other 3 / 0 Date 5. Water availability: [ ' Acceptable service can be provided to this project ❑ Acceptable service cannot be provided to this project unless the improvements in Item B -2 are met. ❑ System is not capable of providing service to this project. B � /� / Y tektkeN 2. j f No improvements required. 3. The improvements required to upgrade the water system to bring it into compliance with the utilities' comprehensive plan or to meet the minimum flow requirements of the project before connection and to meet the State cross connection control requirements: RECEIVED CITY OF TUKWI J, (Use separate sheet if more room is needed) 4. Based upon the improvements listed above, water can be provided and will be available at the site with a flow of I L,9 A gpm at 20 psi residual for a duration of 2 hours at a velocity of ( fps as documented by the attached calculations. This certificate is not valid without Water District #125's attachment entitled "Attachment to Certificate of Water Availablity" \applications \water availability (7 -2003) Printed: 9 -16 -03 (City/County) OCT 1 0 2007 PERMIT CENTER /D— /0—C' 7 Date £ ;p;.ets 0-0_10_4>s) Attachment to Certificate of Water Availability King County Water District No. 125 The following terms and conditions apply to the attached Certificate of Availability ( "Certificate ") 1. This Certificate of Water Availability is valid only for the real property referenced herein for the sole purpose of submission to the City of Tukwila ( "City"). This Certificate is issued at the request of the City and is not assignable or transferable to any other party. Further, no third person or party shall have any rights hereunder whether by agency or as a third party beneficiary or otherwise. 2. The District makes no representations, expressed or implied, the applicant will be able to obtain the necessary permits, approvals and authorization from the City or any other applicable land use jurisdiction or governmental agency necessary before applicant can utilize the utility service which is the subject of this Certificate. 3. As of the date of the issuance of this Certificate, the District has water available to provide utility service to the real property which is the subject of this Certificate, and the utility systems exist or may be extended by the applicant to provide service to such property. However, the issuance of this Certificate creates no contractual relationship between the District and the applicant or the City, and the issuance of this Certificate may not be relied upon and does not constitute the District's guarantee that water utility service will be available to the real property at the time the applicant may apply to the District for such service. 4. Application for and the possible provision of District utility service to the real property which is the subject of this Certificate shall be subject to and conditioned upon the availability of water service to the real property at the time of such application, as well as all application for utility service, including conservation, water restrictions, and other policies and regulation then in effect. Applicant's Signature r Date \ \` )°\ \ F\-- � District Representative !l4 2112 -ice Date 10 - /o -o7 License Information License SIDHUHI980NO Licensee Name SIDHU HOMES INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602228341 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 4224 S 148TH ST Address 2 City TUKWILA County KING State WA Zip 98118 Phone 2062441900 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/20/2002 Expiration Date 8/30/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 CBIC SF7678 09/01/2004 Until Cancelled $12,000.00 08/30/2004 #1 CBIC SF7678 09/01/2004 Until Cancelled $12,000.00 08/30/2004 Business Owner Information Name Role Effective Date Expiration Date SINGH, GURDIP PRESIDENT 08/20/2002 Look Up a Contractor, ElectriPian or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SIDHUHI980NO 11/14/2007 1 1 SL .t;Ol toee J • r e a-i- / tX % 3 a� °o o Arn -P " FILE E COPY Permit No• Ran r(Iview appmel eutiecito WON end omissions. Approval of conelmolloo documenraWoodlarks the violation of sty adopted cods oradinina Receipt of approved Capyardecallonsisadmodedieck BY 1 n of Tub& BUILDING DIVISION I I [ '. I — 0 I °N° 63 0-7-• • II II I J a • REVISIONS No changes shall be made to the ape of work Tukwila Building approval g Tu NOTE: Revisions will require a new plan submittal and may include additional plan review oPP - •rrr. rr r • J H tn t�9 1 8 g O( � (V N I! 11 cm 0 2 r2 fk II 0p �k (2o u _ cip 7C K UJtL FOR 3 CODE COMPLIANCE PPNIGNE r aZ 0 F- U z z 0 U r 001ft O co co co N WOO pinos ]nhgAv acv ?t7 J NlnoG gnNgAV N1Di V cif la c_ —0 W ' Nxb-,0£ c o > Go 7 Date: z I -, I I 00 I I 1 I tn RECEIVED CITY OF T11KIA /11., • NOV 06 20Gi PERMIT CENTER !Lt r z w U7 • • These plans have been reviewed by the Public Works Department for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards or ordinances. The responsibility . for the adequacy of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent Final acceptance is subject to field inspection the Public Works utilities inspector. By I 3 ti 4 Q 7. 1 C ows . h • CORRECTION I.TR# I I 1 1 I I I T I E.EL. =284.5 I' I t<4" WINDOW TRIM STUCCO I "X4" TRIM OVER 2 "X 10" BARGE BOARD STUCCO AT GABLES TYP. GARAGE ROOF DROPPED I ' - I2 P.EL.= 282.35' E.EL.= 280.37' 8' r I IGI1 DOOR. IRUP 3R UP EKONT ELEVATION 36" MINIMUM HANDRAILS TYP == IMEt m= IMEM== IMEM= MIMIIIrwIMI■ MIII■ rrrIIIIIll ■Nrtmmimmomlllmingtmminil mmwmpr / ruimiiirlilliiiiimmmiu mioll • •1 11 11 11 CONCRETE TILE ROOF 11 1 1 II I I 11 1 N. GUARDRAILS E.EL.= 284.5 I I 1 1 1 1 I I 1 1 1 1 I I 1 1 1 1 1 1 h u l l 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MARDI -PLANK SIDING WITl1 CORNER TRIMS 125.G. 7 36" MINIMUM HANDRAILS TYP. I2 P.EL.= 283.00' P.EL.= 283.00' CONCRETE TILE ROOF 12 RIGHT ELEVATION % 0D/3 61-1 P.EL.= 283.50' E.EL.= 284.22' CODE COMPL ANLt 3 APPRO NOV I ', 2T1 City Of Tukwila LNG a ¢0 BUILDING 12 42" MINIMUM GUARDRAILS PROPOSED RESIDENCE FOR SIDhU HOMES INC. LOT I -B, 46XX SO. 148Th ST. TUKWILA, WA. (206) 244 - 1 000 DD07- 4237 -P1 • . I P � � r T � cR f ilc1�c1 0 ptwold&AR Qua .S • Macy, P o 1;01 Zi4 P 7 O <nv 9 TOP OF PLATE= 303.89' TOP FLOOR= 294.83' 12 MAIN FLOOR= 284.94' • -J -A IT II II II II II II II II IT II II IT IIII JI_IT II II I_LII II ITTI II P.EL.= 283.50' E.EL.= 284.22' 12 7 16 16, 1►. 20 aiRiRi.i.M...i_Iri - uLIUaHLUHIlly LIIIUH L ` Littilli Pr' i w r_ _w. _ rr_ —. ^_ —_ ∎.rrrr __r r —.—_ —_ rr.rr_ ■•■■ —r rrrr _ r_ r•— .- - ■■. rrrii_-- ^. —rw —_ w.— ..— _— ■— ri--- .-- - — . __ r —. H H I I H 1111 11 11 1 25 HARDI- -PLANK SIDING WITH CORNER TRIMS U 20 REAR ELEVATION U H I I I I I f I I I I 1 HARDI -FLANK SIDING WITH CORNER TRIMS 12 II II I I II 11 11 30 6 MIT P.EL. =281. 1.2 E.EL.= 279.42' I2 • AMINO NMI lib, w ►. P.EL. =28 I .42' E.EL.= 279.42' 12 1 20 L I T I II 1 1 I T I I I II i I 11 CONCRETE TILE ROOF I T L I I J HARDI -PLANK SIDING WITH CORNER TRIMS 1I I I` I I I T 11 I I I i I II l i 1 1 1 I 1 I 1 T 11 i I I i I I I L 17 20 I I I 11 I I I I I 1 7 I I I I 11 1 1 1 L I I I I I I I I I I I I 11 I, I I 11 I I I HARDI -PLANK SIDING WITH CORNER TRIMS 16 LEFT ELEVATION buT- L L I CODE COMPLIANCE. APPROV NO Ohl Of 1\ ANN Ra BUILDING D' S- N r�wwwl���� ■w•w���w•w�wr ■w�w�wA ■�I ■wow ■w.w�nw ■www��•w■��w ■w•�rywr J I I I r•_ 11.. LU L__ALL._ 1111 lT 1I 111111 II 11 11 I1 11 11 II IT II II 11 II 11 1111 P.EL.= 282.35' E.EL.= 280.37 12 r 1RUP 1 DWN: SCALE: DATE: CHKD: PHONE: • ,v Con TITLE PROPOSED RESIDENCE FOR 51D1 HOMES INC. LOT 1 -13, 4GXX SO. 1451 TUKWI LA, WA. I/4"-I' SEP. 17. 2007 (206) 244- I S00 DRAWING NO. DD07- 4237 -P2 g -tut s . lvl€c ve u,rr J1L71 t3/4: 206- - 7�" RECEIVED CITY OF TUK'WIIA OCT 1 0 2007 Wti- twill CENTER t. ti LL LEGEND: AN 45Mor { ALARM TF.D. -50 CFM EX. FAN -SMOKE ALARM -FLOOR DRAIN I0' -1#" I6 FAMILY KM. 3 -2 "x I O" 13' -8" Q 12 2"44 @ 16" o. I7' -1 28' Q 6`X5' BEDROOM WALL GIRDER GARAGE ROOF DROPPED I' -8" SOLID CURE, WEATHE TRIP SELF -CL • SER GARAGE 7'-92" I ' -4" Cfl 4' 3 -2 "x I OR ARCH NAY 5 :" 36" MINIMUM HANDRAILS TYP_ 0 N --I I- 3 -2 "x I O" 8' 43'-4" 4' -G" • 4' -G" 1 8'x24" MIN. CRAWL SPACE ACCESS UNDER. STAIRS 9 2' -8" 48' 9' Q 5'Y 3 -2"x I O" NOOK 9' -8" 1 -4 MAIN FLOOK SCALE: I /4 "- I' 4 I GR. UP 3R UP 7' -4" MAIN FLOOR AREA =1,930 SQ.FT. GARAGE AREA =612 SQ.FT. TOTAL MAIN FL. AREA =2,542 SQ.FT. 2R. UP \I/ "8,9,8,2 FRENCH DO R "8,9)C,8,Z ENTRY /FOYER 2 -3'X8' 6X4' ARCH WIN. ABOVE CV x l N m) 8'-1 " 11 REF WALL GIRDER 42" MIN MUM GUARDRA LS TYP. 3G" MIN MUM HANDRAILS TYP. 1 G' -5" KITCHEN DINING 5 4'14 A o 1G' LIVING VAULTED CEILING 1 G' 11- 3- 3'XIO' WINDCW5 INCL. ARCH ® 3' -4" 12' -8" 8' -4" 3' -4" 00 010 110 s 1 C" C9 N ti ) to 0 r; DESIGN SETTINGS Design Code: IBC Wind Capacity Increase: Shear = 1.40; CSC Panels = 1.50; Withdrawal = 1.60 Wind: Sheathing capacities are added together Seismic: Use greater of strongest or twice weakest sheathing capacities. Seismic Load Reduction Factor = 0.70 Shearwall Relative Rigidities based on Flexible Design Holddown Forces based on Applied Force Max Shearwall Offset: Plan = 4.00'; Elevation = 1.67'; Height to Width Ratio = 3.50 SITE INFORMATION IBC Occupancy: Category I; ASCE Equivalent - Category II WIND: ASCE-7 98 General analytic method for all buildings Design wind speed = 100mph; Exposure C; Enclosed building SEISMIC: ASCE -7 98 Equivalent Lateral Force Procedure Use Group I; Seismic Design Category D; Site profile class D Spectral response accelerations S1 = 0.400g, Ss = 0.750g Fundamental period T: T used = 0.178s; Approximate Ta = 0.178s; Maximum T = 0.303s Reliabiliy factor rho = 1.00; Response modification factor R = 6.00, 4' -8" 4 -S" tr 4 -4" 5/0 TUB/ SHOWER 4' -4° BEDROOM# I 7 5 -4" W.I.C. ,g,9X £ 2'8 'xG &'PD C. BATI1 ...4-, Dr WN p - /VS T/6 a L = STHD 14 13 -8" BEDROOM #2 2'8'x6' - - I „8,9X,£ \\„A 13 -8" 2'- I 0" 3 -G" 7 -4" CJ� niaba 0 4 -4" W.1.C. SMOKE ALARM 2'8"x6'8" tis x- NICHE WITH ARCHED TOP 8 INCL_ ARCH 9 23'-4" MATERIALS by WALL GROUP Wall Sheathing [in] Fasteners: Grp Surf Material Thickness Or Size Type $ Cat CC incl -_ ©CD ^ Vcrt 2 Nail Ext SS incl. OSB 7/16 Vert 8d Nail Both SS incl. OSB 7/16 Vert 8d Nail es: 1. Capacity has been reduced according to IBC specific 1 9' BEDROOM #3 4 -4" SMOKE ALARM Spacing[in] Framing Edge Field Blkg Species ' yea IIem I'ir O I 6 5x4' C17 N- i -8" gravity adjustment. 48' 13' -8 6 6 yes Hem -Fir 0.43 24 1 3 6 yes Hem -Fir 0.43 24 1 43 MOKE ALARM 2 -2'8 X6'8" 36" 'MUM HANDRAI TYP. 3' TOP FLOOK SCALE: 1 /4 "- I' Members [in] Apply G Spacing Notes 22'-4" 12' -8" MASTER BEDROOM 42" MIN. GUARDRAILS TYP. /. PLANTER * \ cib 5'x4' H IIi7Mi II��i! II I G' II��tF VAULTED CEILING' seert 7 -4 TOP FLOOR AREA =1,724 SQ.FT. i 4' -8" ENSUITE #k FAN 20' VAULTED CEILING L 2 8" 1 2'-8" 7 -4" I1ERS 7' -4" FAN 6'x4' JACUZZI J J c� N (1) C (0 to C" cc C,Ot7P:SP,t,CE NP? rtG t:11 C" FLOOD AREA ° �� TOTAL LOT AREA= 30,004 SQ.T• TOTAL AREA=4,266 SQ.FT. NOTES: I . 22 "X28" ATTIC ACCESS TO ALL ROOF SPACES. FAN 2. SPOT VENTILATION VENT TO OUTSIDE. 3. WHOLE HOUSE FAN VENT TO OUTSIDE. FAN P7 TITLE PROPOSED RESIDENCE FOR SIDIU HOMES INC. LOT I-5, 46XX SO. 1 48TH ST. TUKWILA, WA. OWN: SCALE: DATE: CHKD: PHONE: HB I /4 "- I SEP. I 7, 2007 (20G) 244- 1 900 DRAWING NO. DD07- 4237 -P3 RECEIVED CITY OF TUKNII.A OCT 1 0 2007 pt1'"LIvii r eL I tR 6-) co / 4' -8" / f / 5' -4' 3' 5' L / i I' -4" 13' -4" \ Fr) o ' 1 J r -- 0 h L J / 1) 28' 1 3' CRAWL SPACE ACCESS J \ / \ / / \ f \ / \ / \ 1 L f f r 2"x10"© 12 "O.C L 1 1 1 1 / / 4' -7" / 5' -8" / 3' CRAWL SPACE ACCESS Z Th 1 1 1 L Er) 43 -4" 14' 3 CRAWL 5'ACE A :LESS —I 8 "x24" MIN. I (CRAWL SPACE ACCE55 UNDER STAIRS 3' \ f \ / / 1 \ 1 48' 1 SCALE: I /4 " - ' 1 J L 1 1 5' -4" T J L L I 7-4" CRAWL SPACE $ fDN. PLAN 1 L 1 3' -4" FO CO N Fe 0 N Z \ CRAWL SPACE ACCESS CORBE_ FOUNDATION FOR CONCR = TE STEPS. NO CONCRK E AGAINST WOOD. 3' CRAWL SPACE ACCESS 3' CRAWL SPACE ACCESS 1G' I C' 1 C "X6" POST — I ON I0 "XI0" CONC. PIER ON 3'X3'X I a' CONC FOOTING TYP. 12 �n m L354 cow Ot I0011,13 pal 1.01 .. 2- 6 B ee' 7 `69-7 NEC 250.50. A concrete encased grounding electrode is required in all new concrete footings. The electrode shall consist of at least 20 feet of %Z" or larger reinforcement bar or #4 copper wire, located near the bottom of the building footing. (NOTE: 20 foot rebar shall be one continuous piece tied along side any vicinity footing rebar and shall protrude 8" min. above top of foundation wall near location of power panel.) r 1 2 "x I O "@ I 2 "O.C. G. G" 3 `WI 6' 6" J�� L TITLE i Z 5-- DWN: i 1115 SCALE: 3' CRAWL SPACE ACCESS - - - - -1 6-) co / 4' -8" / f / 5' -4' 3' 5' L / i I' -4" 13' -4" \ Fr) o ' 1 J r -- 0 h L J / 1) 28' 1 3' CRAWL SPACE ACCESS J \ / \ / / \ f \ / \ / \ 1 L f f r 2"x10"© 12 "O.C L 1 1 1 1 / / 4' -7" / 5' -8" / 3' CRAWL SPACE ACCESS Z Th 1 1 1 L Er) 43 -4" 14' 3 CRAWL 5'ACE A :LESS —I 8 "x24" MIN. I (CRAWL SPACE ACCE55 UNDER STAIRS 3' \ f \ / / 1 \ 1 48' 1 SCALE: I /4 " - ' 1 J L 1 1 5' -4" T J L L I 7-4" CRAWL SPACE $ fDN. PLAN 1 L 1 3' -4" FO CO N Fe 0 N Z \ CRAWL SPACE ACCESS CORBE_ FOUNDATION FOR CONCR = TE STEPS. NO CONCRK E AGAINST WOOD. 3' CRAWL SPACE ACCESS 3' CRAWL SPACE ACCESS 1G' I C' 1 C "X6" POST — I ON I0 "XI0" CONC. PIER ON 3'X3'X I a' CONC FOOTING TYP. 12 �n m L354 cow Ot I0011,13 pal 1.01 .. 2- 6 B ee' 7 `69-7 NEC 250.50. A concrete encased grounding electrode is required in all new concrete footings. The electrode shall consist of at least 20 feet of %Z" or larger reinforcement bar or #4 copper wire, located near the bottom of the building footing. (NOTE: 20 foot rebar shall be one continuous piece tied along side any vicinity footing rebar and shall protrude 8" min. above top of foundation wall near location of power panel.) /J = `WI J�� TITLE PROPOSED RESIDENCE FOR SIDNU HOMES INC. LOT I -B, 4GXX SO. 148Th ST. TUKWILA, WA. DWN: i 1115 SCALE: I /4 "- I' DATE: 5EP. I7, 2007 CHKD: PHONE: (20G) 244- I 000 DRAWING NO. DDO7- 4237 -P4 ...,) RECEIVED CITY OF TUkWI' A 0Cf10 PERMIT CENTER ----4::< c r il t 6-) co / 4' -8" / f / 5' -4' 3' 5' L / i I' -4" 13' -4" \ Fr) o ' 1 J r -- 0 h L J / 1) 28' 1 3' CRAWL SPACE ACCESS J \ / \ / / \ f \ / \ / \ 1 L f f r 2"x10"© 12 "O.C L 1 1 1 1 / / 4' -7" / 5' -8" / 3' CRAWL SPACE ACCESS Z Th 1 1 1 L Er) 43 -4" 14' 3 CRAWL 5'ACE A :LESS —I 8 "x24" MIN. I (CRAWL SPACE ACCE55 UNDER STAIRS 3' \ f \ / / 1 \ 1 48' 1 SCALE: I /4 " - ' 1 J L 1 1 5' -4" T J L L I 7-4" CRAWL SPACE $ fDN. PLAN 1 L 1 3' -4" FO CO N Fe 0 N Z \ CRAWL SPACE ACCESS CORBE_ FOUNDATION FOR CONCR = TE STEPS. NO CONCRK E AGAINST WOOD. 3' CRAWL SPACE ACCESS 3' CRAWL SPACE ACCESS 1G' I C' 1 C "X6" POST — I ON I0 "XI0" CONC. PIER ON 3'X3'X I a' CONC FOOTING TYP. 12 �n m L354 cow Ot I0011,13 pal 1.01 .. 2- 6 B ee' 7 `69-7 NEC 250.50. A concrete encased grounding electrode is required in all new concrete footings. The electrode shall consist of at least 20 feet of %Z" or larger reinforcement bar or #4 copper wire, located near the bottom of the building footing. (NOTE: 20 foot rebar shall be one continuous piece tied along side any vicinity footing rebar and shall protrude 8" min. above top of foundation wall near location of power panel.) ..0! BATH W.I.C. TOP Of PLATE= 303.89' i ii HEADERS. 11 HER. W.I.C. (SIZE DETERMINED STUDS 2X4 @ 12 "O.C. BY OPENING WIDTH) /— MASTER BEDROOM R TOP FLOOR= 294.83' R 2 X TRUSS Of ROOF FRAMING R -38 ATTIC INSULATION /2' DRYWALL 2 "x6" BOTTOM TREATED PLATE I 0" x 5 /a' ANCHOR BOLTS 7" EMBEDMENT FINISHED GRADE 8'THICK CONC. WALL DRAIN TILE -al iiiiiiiiiii ROOF VENTS: 15Q. FT. OF VENT FOR EA. 150 SQ.FT. OF ATTIC FOUNDATION 0 9 36" MINIMUM HANDRAILS TYP. FAMILY RM. #(4) @ 48" O.C. FOR CONSTRUCTION JOINT (I) #4 CONTINUOUS REBAR 12 R -30 INSULATION TYP. STAIR D ETA! L SCALE: I /2 "- I ' P4 ENGINEERED TRUSSES @24 O.C. BY TYP. FLOOR CONSTRUCTION: I " T4G PLYWOOD T.J.I. JOISTS WI CROSS BRIDGING OR BLOCKING MAIN FLOOR= 284.94' G MIL BLACK VAPOR BARRIER NOOK I " PLYWOOD STEPS AND NOSING `►% il∎' I%I►`A ► ' ►. ,1 ►. ∎ANI.;►.,..t∎ mi , i l ►.., ►_, ►_,;► A►_, ► 1 ►_, ►_,►_,►_,l►_, ,►► i� ' : ∎_•,A► ► KITCHEN 10' JOISTS OR SIZE OF TJI AS NOTED BY ENGINEER Note: Section notes by P. Eng. shall have precedence over designer's notes. TYP. EXT. WALL CONSTRUCTION: HARDIPLANK SIDING BUILDING WRAP /2' SHEATHING 2 "XG" STUDS @I G" O.C. R2 I BATT INSULATION /2' GYPSUM BOARD CONC. TILE ROOF 1X4 STRAPPING, BUILDING PAPER. GUTTERS FINISH TO CODE - FRAMING - INSULATION - VAPOUR BARRIER - DRYWALL FINISHED GRADE > � /jam /j�/j� / }�/%1/� \ �� \ PROPOSED RESIDENCE FOR SIDHU HOMES INC. LOT I -B, 4GXX 50. 1 48Th ST. TUKWILA, WA. RECEIVED CITY OF TUK■II_A OCT 1 0 2007 PERMIT CENTER BEARING WALLS NON BEADING WALLS Stud Size (inches) Laterally unsupported unsu pp stud height (feet) Maximum spacing when supporting pp g roof and ceiling only (inches) Maximum spacing when supporting pp g one floor roof and ceiling (inches) Maximum spacing when supporting pp g two floors roof and ceiling (inches) Maximum spacing when supporting one floor only (inches) Laterally unsupported pp stud height (feet) Maximum spacing (inches) 2X3* - -- - -- -__ - -- - -- I 0 1 G 2X4 10 24 I G - -- 24 14 24 2XG I 0 24 24 I G 24 20 24 NO. MANUFACTURER FRAME MATERIAL MODEL# SIZE QTY. U -VALUE AREA S.F. �C� frlii 8.5"8.5" TITLE PROPOSED RESIDENCE FOR SIDHU HOMES INC. LOT 1 -B, 46XX SO. 148TH ST. TUKWILA, WA. DWN: HB I OASIS WINDOWS VINYL SEP. I 7, 2007 2'X3' 3 PHONE: 6 2 OASIS WINDOWS VINYL 0 c 2'6 "X6' 2 1 5 3 OASIS WINDOWS VINYL 3'X4' I 1 2 4 OASIS WINDOWS VINYL 3'X 10' ARCH -TOP 3 30.2 5 OASIS WINDOWS VINYL 4'X4' 2 I G G OASiS WINDOWS VINYL 5'X4' 4 20 7 OASIS WINDOWS VINYL 5'X5' 1 25 8 OASIS WINDOWS VINYL G'X5' I 30 9 OASIS WINDOWS VINYL 8'X6' ARCH -TOP I 45.4 1 99.6 r 12" 3" G" 2 Story / J 4.5" G" �C� frlii 8.5"8.5" TITLE PROPOSED RESIDENCE FOR SIDHU HOMES INC. LOT 1 -B, 46XX SO. 148TH ST. TUKWILA, WA. DWN: HB SCALE: AS NOTED DATE: SEP. I 7, 2007 CHKD: PHONE: (2O6) 244-1900 DRAWING NO. DD07- 4237 -1D7 RECEIVED CiTY OF TUKWILA OCT 1 0 2007 PG - MI r CENTER L 0 c ----<< I Story 12" 3" G" 2 Story 15" 4.5" G" 3 Story 2.3" 8.5"8.5" General Specifications Contractor or the Owner shall verify all dimensions, materials and conditions shown on the structural drawings or noted in the structural specifications. Any variances within the structural swings and specifications, or from conditions encountered at the job site, shall be I by the Contractor and Owner and such solution shall be their sole 2. The :or and the Owner shall ensure that the construction complies with all federal, state, and local statutes and regulations. 3. The :or or Owner shall install all materials, equipment and components etc. in accordance with the manufacturer's instructions and accepted methods of good building 4. The designer shall not be responsible for site conditions such as soil bearing capacity, depths of frost Ines or water tables, or buried structures, etc. The purchaser of these plans shall be responsible of these plans * shall be responsible for the correct siting on the house of the property and for confirming with all requirements for siting. We do not guarantee that a house plan will fit a particular property unless we receive in advance of the plans purchased, a legal survey plan of the property and a copy of the applicable zoning by-laws stating he required setbacks from all property lines, and unless we undertake in writing that the souse will conform to the siting regulations of the by -laws for the particular parcel of land. 5. Construction loads on the structure caused by interim storage of materials or use of equipment shall not exceed the design loadings. G. The designer shall not be responsible for any departure from the drawings and specifications authorized by any official during the course of construction. Dimensions shall in all cases take precedence to scale. A. Monolithic footing./slab: R.403.1.3.2 Per 8403.1 grade shall fall a min. G" in the first 10" or footing dram shall be installed R40I.3 8405.1 C E E MONOLITHIC SLAB R403.1.4.2 12" single story 15" two story 23" three story '"Slab Insulator per State Enery Code I -#5 bar cast momolithic in center 3rd of footing, or #4 rebar top and bottom -min. 40 diameter lat at splices secured with tie wire TYPICAL FOOTING AND FOUNDATION DETAIL SCALE: 1 /2 "- i ' WINDOW SCHEDULE GLAZING /SKYLIGHT BY TYPE B. Typical footin• foundation General Notes Minimum insulation required to comply with the Washington State Energy Code is as follows: Floor (slab): R -30 Wall: R-2 I Ceiling: R -38 Doors: Wood or Fiber -optic Windows: Vinyl (summit or better) Furnace type: Gas or Electric Minimum furnace afue: 80% Refer to Wattsun 5.G energy calculation by design consultants, Inc. for verification of these values. 1. VERIFY SHEAR WALL NAILING AND HOLDOWNS PER PLAN AND SCHEDULE PRIOR TO INSTALLING SIDING. 2. MASONRY AND WOOD FRAME CHIMNEYS ARE TO BE CONSTRUCTED PER I.B.C. 3. CAULK ALL EXTERIOR JOINTS AND PENETRATIONS. 4. PROVIDE GALVANIZED OR ANODIZED SHEET METAL FLASHING AND COUNTERI'LASHiNG AT ALL ROOF PENETRATIONS, CHIMNEYS AND SKYLIGHTS. 5. PROVIDE CONTINUOUS METAL GUTTERS AND DOWNSPOUTS AT ALL EAVES, TYPICAL. 1 /2" Dam. x 10" long anchor bolts @ G' -O" o.c. 4 max. 12" from ends w /3 "x3 "x 1 /4" steel plate washers at each bolt,typ;cal minimum #4 rebar top and footing cont. -40 diameter tap at splices stemwalls higher than 4' will recfuired design as retaining wall or constrained basement wall #4 vent. @ max. 45" o.c. wl min. 14' extension into stem wall at splice. Mm. G" hook W P TYPICAL FOOTING AND FOUNDATION DE I AIL SCALE: 1/2"-1' TABLE DG02.3 (5) SIZE, HEIGHT AND SPACING OF WOOD STUDS D STRUCTURAL NOTES: CODE IBC 2005 AND ASCE 7 -02 DESIGN LOADS ROOF LIVE LOAD FLOOR LIVE LOAD WIND: 85 MPH EXPOSURE B 25 PSF 40 PSF ALLOWABLE SOIL BEARING PRESSURE: 2000 PSF SEISMIC: SEISMIC DESIGN CATEGORY "D" (IBC) FOUNDATION FOUNDATION DESIGN FOR GRAVITY LOADS IS BASED ON AN ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. CONCRETE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF CONCRETE FOUNDATION SHALL BE 2500 PSI. USE 5 -94# SACKS OF TYPE I OR TYPE II CEMENT PER CUBIC YARD OF CONCRETE WITH 5-i GALLONS Of WATER PER SACK OF CEMENT. MAXIMUM SLUMP 6 ". MINIMUM SLUMP 2 ". REINFORCING REINFORCING SHALL BE DEFORMED BARS IN ACCORDANCE WITH ASTM AG 15 GRADE 40. WELDED WIRE fABRIC TO BE PER ASTM AI 85. LUMBER LUMBER FOR JOISTS, RAFTERS AND HEADERS SHALL BE HEM -FIR #2 (WHERE HEADERS ARE MULTIPLE 2x'S) STUDS AND PLATES: HEM -FIR STANDARD GRADE FOR 2x4'S HEM -FIR #2 FOR 2x6'S BEAMS 4" WIDE: DOUGLAS FIR / LARCH #2 BEAMS G" AND WIDER: DOUGLAS FIR / LARCH #2 COLUMNS: DOUGLAS fIR / LARCH #2 OR HEM -FIR #2 (P.T. AT DECKS) GLU -LAM BEAMS: DOUGLAS FIR / LARCH 24r -V4 MAXIMUM MOISTURE CONTENT Of ALL FRAMING LUMBER AT THE TIME OF CONSTRUCTION SHALL BE 19 %. PROVIDE 2 STUDS MINIMUM AT EACH WALL END. Note: Whole house ventilation system shall supply outdoor air to all habitable rooms through Individual outdoor air Inlets. habitable space Is defined as space In a structure for living, sleeping, eating or cooking. Bathrooms, toilet compartments, closets, halls, storage or utility spaces and similar areas are not considered habitable spaces. Provide not less than 4 sq. in. of free area of opening for each habitable space, Whole house ventilation requirements for 5 bedrooms shall be a minimum of 120 CFM at .25 w.g. nutone qt. 80 is G2 CFM at .25 w.g. *Use two qt. 80 nutone fans each on clock timers. Structural Specifications I . Concrete a) General: all concrete to be minimum 2500 p.s.i. strength at 28 days unless otherwise specified. b) Walls: grades shown on side elevations are arbitrary. Owner or builder to adjust height of concrete walls to suit grade and adjust thickness of walls to conform to the height if required. Retaining walls other than the foundation walls of the residence are beyond the scope of these drawings. c) Footings: concrete footings must be placed on undisturbed or compacted soil at an elevation below the frost line. It shall be the responsibility of the owner or builder to have the footings redesigned to suit existing conditions. d) Retaining walls: backfill shall not be placed against basement retaining walls until: I) Concrete or masonry grout has reached its 7 -day strength ii) And, the structural floor framing (incl. Plywood subfloor) required to stabilize the walls is complete and fully nailed and anchored. e) Reinforcement shall be placed according to good building practice and adequately supported by concrete, metal, or other approved chairs, spacers or ties and secured against movement during pouring concrete. Tack welding is not permitted. 2. Framing a) This plan Is designed for a 25 p.s.f. Snow load and a 10 p.s.f. Dead load. It shall be the responsibility of the owner or builder to determine the snow load in the area in which the residence is being built and make adjustments in the size of the structural members to compensate for additional loading, to the satisfaction of local building authorities. b) The design of members used for structural purposes has been based on No. 2 or better Hem fir as shown in the "Span Tables for Wood Joist Rafters and Beams" in the most recent edition of the International Building Code. The use of different species of wood must conform to the same tables. c) All lintels to be 2 -2 "x i 0" unless noted otherwise. All load bearing beams and lintels shall have 3 V2" minimum bearing. d) All concrete to wood contacts shall be dampproofed with Gml polyethylene or 45 lb. Tar saturated felt or pressure treated wood. e) flash over all exterior openings. f) Caulk under exterior doors and both sides of chimney. 3. Plumbing * Electrical All materials, equipment and methods of installation shall be in accordance with the conditions as provided for in the International Building Code, and applicable state or local codes. When the owner's property is not located on a municipal sewer system, the owner or contractor shall be responsible for the submission of plans to the Building Dept. for approval of a septic tank and drain field in accordance with current local requirements. 4. Heating a) All hot air ducts to be overhead in attic, unless specified otherwise. b) Cold air return registers to be located and installed for maximum efficiency by qualified heating contractor. 5. Roofing a) Roofing materials to comply with the applicable section of the international Building Code. G. Windows a) All sash must be approved by local authorities - vinyl and slide openings unless otherwise indicated. 7. Site plan a) Customer or builder to provide property elevations at points marked before applying for mortgage or building permit. b) Customer to provide north arrow on blank compass rose provided at site plan. 8. Miscellaneous a) Base moulding at all floor and wall junctions where required b) Provide drop ceiling over 5' tub and shower, grab bar, shower curtain rod, towel bar, and tissue holder (provide backing) c) Floor finishes bathroom vanities, bath splash, and kitchen cabinets to specifications of owner or builder. 14 4 ?' nrV \Ao Note: �\ 1 C a - Owner /builder to supply any missing dimensions requirec���'� on site plan. Legal description, name of street(s), north arrow, floor and lot elevations, location of services, etc. - Ail dimensions shown on site plan to be governed and approved by all authorities having jurisdiction before starting construction. - Grade to slope a minimum of I To away from building for surface water run -off, builder to be responsible for any required swales. -Any retaining walls required to be built according to good practise and are entirely the responsibility of others. -All grades, elevations, and dimensions shown on site plan to be checked and verified on site by builder before excavation. aa'!R: 4/24/ 0 9 e7C7 FLOOR PLAN NOTES 1 . ROOM IDENTIFICATION: Each room and the intended use must be clearly defined on the plans by the applicant for In review purposes. R I O6 2. EGRESS WINDOWS: IRC Section R3 1 0. All sleeping rooms and basements with the habitable space shall have at least one openable emergency escape and rescue opening. Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet. Except that grade floor openings shall have a minimum net clear opening of 5 square feet (see definition below). The minimum net clear opening width dimension shall be 20 ". The openings shall have a finished sill height not more than 44" above the floor. Emergency escape and rescue openings shall be operational from the inside of the room without use of keys or tools. Window wells shall be provided when egress windows have a finished sill height below adjacent ground elevation. The well shall allow the window to be fully opened and provide a minimum accessible net clear opening of 9 square feet, with a min. dimension of 36 ". Window wells with a vertical depth of more than 44" shall be equipped with a permanent ladder. Grade floor opening definition: A window or other opening is not more than 44" above or below the finished ground level adjacent to the opening. Refer to handout for additional information . 3. SMOKE ALARMS: IRC Section R3 13. A smoke alarm shall be installed in each sleeping room, outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements. Each floor and basement shall have at least one detector. All smoke alarms shall be listed and installed in accordance with the IRC Code and the household fire warning equipment provisions of NFPA 72. When more than one smoke alarm 15 required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Required smoke alarms shall receive their primary power from the building wiring and shall be equipped with a battery backup. Additions, interior alterations, and repairs shall be provided with smoke alarms as required for new dwellings; the moke alarms shall be interconnected and hard wired. (Exception: Smoke alarms are not required to be interconnected and hardwired where the alteration or repairs does not result in the removal of interir wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, basement available which could provide access for hard wiring and interconnection without removal of hard finishes. Repairs to the exterior surfaces of dwellings are exempt from these requirements) . 4. SAFE I Y GLAZING: iRC Section R308. All glass located in areas considered hazardous must be safety glazed as identified by the manufacturer's or installer's label. The following shall be considered hazardous locations: I . Glazing in swinging doors. 2. Glazing in fixed and sliding door assemblies and panels in sliding and bifold closet doors. 3. Glazing in storm doors. 4. Glazing in all unframed swinging doors. 5. Glazing in doorsand enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and shower. Glazing in any part of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than GO- inches measured vertically above any standing or walking surface. G. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24 -inch arc of the door in a closed position and w bottom edge is less than GO" above the floor or walking surface. 7. Glazing that meets all of the following conditions: 7.1 Exposed area of an individual pane is greater than 9 square feet. 7.2 Exposed bottom edge is less than 18" above the floor. 7.3 Top edge greater than 3G" above the floor. 7.4 One or more walking surfaces within 3G" horizontally of the plane of the glazing. 5. All glazing in railings. 9. Glazing in walls and fences enclosing indoor and outdoor swimming pools, hot tubs, and spas where the bottom edge of the glazing is less than GO- inches above a walking surface and within G0" of the water's edge. i 0. Glazing adjacent to stairways, landings and ramps within 3G" horizontally of a walking surface when the exposed surface of the glass in less than GO" above the plane of the adjacent walking surface. 1 I . Glazing adjacent to stairways within GO" horizontally of the bottom tread of a stairway in any direction when the exposed surface of the glass is less than GO" above the nose of the tread. See code for exceptions for Items 1 through 11. 5. EXHAUST FANS: IRC Section M 1506, WSVIAQ Section 302.2.1 , IMC Section 501 .2, 502.7.3.G. Exhaust fans are required in each kitchen, bathroom, water closet room, laundry facility, indoor swimming pool. spa and other rooms where excess water vapor or cooking odor is produced. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic or crawl space. The termination point shall be located at least 3 -feet from the property line. See energery section of this checklist for more specific requirements. G. RANGE HOOD: IRC Section M 1502, M 1 503, M 1 504, M 1901.1 IMC Sections 304.8, 505. Overhead exhaust hoods shall discharge to the outdoors through metal exhaust hood (galvanized steel, stainless steel, or copper) not less than 28 gage. Such ducts shall have a smooth inner wall and be air tight and equipped with a backdraft damper. Clearance of at least 24" shall be maintained between the cooking surface and the combustible material or cabinet. Exception: Duct material and clearance where installed in accordance with the manufacturer's installation. Clearances to combustibles shall include such considerations as door swing, drawer pull, overhead projections or shelving and window swing, coverings and drapes. Refer to WSVIAQ Section 302.1 & Table 3 -1 for more specific reguuirements. FLOOR PLAN NOTES -- continued 7. WATER CLOSET CLEARANCE: IRC Section R307, UPC Section 405.G. Water closet shall be located in a clear space not less than 30" in width. The clear space in front shall not be less than 24 ". 8. SHOWER AREAS: IRC Section 8307, UPC Section 41 2.6, 4 ! 2.7, 41 2.8. Bathtub and shower floors and walls above bathtubs with installed showerheads and in shower compartments shall be finished with non - absorbent surfaces that extend to a height of not less than G -feet above floor. The clear space in front of the shower opening shall not be less than 30 ". All showers shall have a minimum finished interior floor area of 1 024 square inches and shall also be capable of encompassing a 30" circle. These dimensions shall be maintained to a point 70" above the shower drain outlet. 9. CLEARANCE TO COMBUSTIBLES (FIREPLACE $ CHIMNEYS): IRC Sections R808, RI 00 I . 15, R.1 001 . I G, RI 003. 1 i RI 003. 12. Combustible insulation shall be separated a minimum of 3" from heat producing appliances. Exception: Insulation shall be separated in accordance with conditions stipulated in manufacturer's listing. When masonry chimneys are built within a structure, min. 2" air space clearance to combustibles is required. When the chimney is placed on the exterior of the structure a i " clearance is allowed. The air space shall not be filled, except to provide noncombustible fire blocking. All wood beams, joists, studs and other combustible material shall have a clearance of not less than 2" from the front faces and sides of masonry fireplaces and not less than 4" from the back faces of masonry fireplaces. The air space shall not be filled, except to provide fire blocking in accordance with sections R1 003. 1 3 / RG02.8. Woodwork or other combustible materials shall not be placed within G" of fireplace opening. Combustible material placed within i 2" of the fireplace opening (such as mantles or decorative fireplace surrounds) shall not project more than 1/8" for each i " clearance from the opening. i 0. APPLIANCE LOCATIONS: IRC Chapter M 1 307, M2005, IMC Section 303, and UPC Section 308 $ 309. Installation of appliances shall conform to the conditions of their listing and label and the manufacturer's installation instructions. The manufacturer's operating and installation instructions shall remain attached to the appliance. Fuel burning appliances shall not be located in, or obtain combustion air from sleeping rooms, bathrooms, toilet rooms or storage closets. Exception: 1) direct vent appliances that obtain all combustion air from the outdoors or 2) Appliances located in a dedicated enclosure in which combustion air is taken directly from the outdoorsin accordance with IMC, section 703. Access to such enclosure shall be through a WSEC approved solid door, weatherstripped and equipped with an approved self closing device. Fuel -fired furnaces and boilers installed in closets and alcoves shall be listed for such installation. Equipment installed in outdoor locations shall be either listed for outdoor installation or provided with protection from outdoor environment factors that influence operability, durability and safety of the equipment. Appliances designed to be in fixed positions shall be fastened or anchored in an approved manner. I 1 . APPLIANCES LOCATED IN GARAGE: IRC Section MI 307, IMC Section 303.4, 304.3, IBC I G07.7.3. Appliance located in a garage, carport or other location where subject to mechanical damage shall be protected with approved barriers. Vehicle barrier systems for passenger cars shall be designed to resist a single load of 6,000 lbs. applied horizontally in any diraection to the barrier system and shall have anchorage or attachment capable of transmitting this load to the structure. For design of the system, the load shall be assumed to act at a minimum height of 1 'G" above the floor or ramp surface on an area not to exceed 1 sq.ft. Equipment and appliances having an ignition source shall be elevated such that the source of ignition is not less than at least 1 8" above the floor surface on which the equipment or appliance stands. Rooms or spaces that are not part of the living space of a dwelling unit and that communicate with the private garage through openings shall be considered to be part of the garage and appliances located in the space shall be elevated as specified above. 12. WATER HEATERS: IRC Section M 1307.2, M2005, and UPC 608. Where water heaters or hot water storage tanks are installed in locations where leakage of the tanks or connections will cause damage, the tank or water heater shall be installed in a 24 gage galvanized steel pan or other pan approved for such use. The pan shall be at least I .5" deep and shall be drained by an indirect waste pipe with a min. 3/4" diameter drain to the exterior of the building not less than G" and not more than 24" above the adjacent ground surface. Temperature and pressure relief valves shall be drained to the outsiide of the building. Drain may not be trapped and must terminate not more than 2' nor less than G" above the ground or the flood level of the area receiving the discharge and pointing downward. Water heaters shall be strapped to resist horizontal displacement due to earthquake motion. Twenty -two (22) gage x 3/4" strapping shall be used and be placed at points within the upper one -third (1/3) and lower one -third ( I /3) of its vertical dimensions. At the lower point, a min. distance of 4" shall be maintained above the controls. Lag screws not less than /4" in diameter must be used to anchor the restraints to the wall and each lag screw must have at least 1 thread penetration into a stud wall. A flat washer must be installed between each lag screw and the strap for reinforcement. WSEC Section 504.2. 1 . All electric water heaters shall be placed on an R-1 0 pad when located in an unheated space or concrete floor. 1 3. TRAP PRIMERS: floor drains or similar traps connected to the drainage system and subject to infrequent use shall be protected with a trap seal primer and shall be accessible for maintenance. 14. GARAGE / DWELLING DOOR/ OPENINGS: IRC Section R309. I Openings between the garage and residence shall be equpped with solid wood doors not less than I /8 inches (35mm) in thickness, solid or honeycomb core steel doors not less than i 3 / 8 " thick, or 20- minute fire -rated doors. FLOOR PLAN NOTES - continued 15. GARAGE / DWELLING SEPARATION: RC Section R309.2. The garage shall be separated from the residence and its attic area by not less than Y2" gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5 /8" Type X gypsum board or equivalent. Where the separation is a floor - ceiling assembly, the structure supporting the separation shall also be protected by not less than Y" gypsum board or equivalent. ! G. ATTIC ACCESS: IRC 8807. I . Attics that exceed 30 sq.ft. and have a vertical height of 30" or greater must be provided with min. access openings of not less than 22 "x30 ". The attic access shall be located in a hallway or other readily accessible location with a 30" minimum unobstructed headroom in the attic space above the access opening. 17. EXTERIOR DOORS / EXITS: IRC R3 I I .4. 1 . At least i exit doorway shall be side hinged and not less than 3' in width and not less than G'8" in height. The exit door shall provide direct access from the habitable portions of the dwelling to the exterior without requiring travel through a garage. Access to habitable levels not having an exit shall be by a ramp or a stairway in accordance to applicable IRC Sections 3 1 I .G or 3 1 1 .5. Egress doors shall be readily openable from the side from which egress i5 to be made without the use of a key or special knowledge or effort. 18. LANDINGS: IRC R3 1 I .4.3, R3 I I .5.4. There shall be a floor or landing on each side of all floors. Exception: Where a stairway of two or fewer risers is located on the exterior side of a door, other than the required exit door, a landing is not required for the exterior side of the door. The floor or landing at the required exit door shall be not more than 1%2" lower than the top of the threshold of the doorway. Exception: The landing at an exterior doorway shall not be more than 7 - below the top of the threshold, provided the door, other than an exterior storm or screen door, does not swing over the landing. The width of each landing shall have a minimum dimension of not less than 3G" measured in the direction of travel. The walking surface of landings shall not have a slope greater than 4" per foot. i 9. GUARDS: IRC Section R3 i 2. IBC Section 1 607.7. 1 . Porches, balconies, or raised floor surfaces located more than 30" above grade or floor below shall have guards not less than 3G" in height. Open sides of stairs with a total rise of more than 30" above the floor or grade below shall have guards not less than 34" in ht. measured vertically from the nosing of the treads. Open side of guards shall be designed such that a sphere 4" in diameter cannot pass through. Handrail assemblies and guards shall be able to resist a single concentration load of 200 lbs., applied in any direction at any point along the top, and have attachment devices ap and supporting structure to transfer this loading to appropriate structural elements 0 A. of the building. immediate rails (all those except the handrail), balusters and panel fillers shall be designed to withstand a horizontally applied normal load of 50 lbs. on an area equal to 1 sq.ft., including openings and space between rails. 20. HANDRAILS: 1RC Section R3 I I .5.6, R3 I I .5. 1 . All stairways with 4 or more risers shall have at least one handrail, Such handrails shall be placed not less than 34" nor more than 38" above the nosing of the treads. Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top riser to a point directly above the lowest riser. Handrail ends shall be returned or terminate in newel posts or safety terminals. Handrails adjacent to the wall shall have a space not less than IY2" between the wall and the handrail. Circular handrails shall have an outside diameter of at least I 4" and not greater than 2 ". Handrails with a perimeter greater than GY ' shall provide a graspable finger recess area on both sides. See handrail option in IRC Section 3 1 i .5.6.3 for additional handgnp requirements. Handrails shall not project more than 4Y2" on either side of the stairway. See #34, stairway width for additional information. Refer to handout. 21 . STAIR WIDTH: IRC Section 3 I I .5.1 . Stairways shall not be less than 3G" clear width at all points above the handrail height and below the required headroom height. ? shall not project more than 4Y2' on either side ?_ and landings, shall not be less than 3 1%2" where the handrail is installed on one side and 27" where handrails are installed on both sides. a 22. STAIR TREADS * RISERS: IRC Section 3 I I .5.3. The maximum riser height shall be 7- 3 /4 ". The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 ". The minimum tread depth shall be i 0 ". The tread depth withinany flight of stairs shall not exceed the smallest by more than 3/8 ". A nosing of not less than 3 / 4 " but not more than 1Y shall be provided on stairways with solid risers. Open risers are permitted, provided that the opening does not permit the passage of a 4" diameter sphere. Exception: Nosing is not required where the tread depth is at least 11". The opening between adjacent treads is not limited on stairs with a total rise of 30" or less. 23. STAIR HEADROOM CLEARANCE: IRC Section R3 1 I .5.2. All parts of the stairway shall not be less than G'8" measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform. See exception for spiral stairways. 24. USABLE SPACE UNDER STAIRS: IRC Section R3 I 1 .2.2. Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed Side with Y2" gypsum board. 25. ILLUMINATION: IRC Section R303.G, R3 I 1 .5.7. All interior and exterior stairways shall be provided with a means to illuminate the stair including landings and treads. Interior stairways shall be provided with an artificial light source located in the immediate vicinity of the landing of the stairway. Exterior stairways shall be provided with a light source located in the immediated vicinity of the top of the landing of the stairway. Lighting controls shall be accessible at the top and bottom of each stairway without traversing any steps. S ac rxPIRRS: 4/24/ © ,/i I DWN: SCALE: DATE: CHKD: PHONE: i1B Pft.4 Con PROPOSED RESIDENCE FOR SIDHU HOMES INC. LOT 1 -B, 4GXX SD. 1 48TH ST. TUKWILA, WA. sEr. 17, 2007 TITLE (206) 244-1000 DRAWING NO. DD07- 4237 44 RECEIVED CITY OF TUKVVII.A OCT 1 O :/ PErtiViI r CENTER Option Glazing Area" % of floor Glazing U- Factor Door' U- Factor Ceiling' Vaulted Ceiling Wall Above Grade Wall= into Below Grade Wall =ext Below Grade floor SIab on Grade Select One Vert Over- head I 1 2% 0.35 0.58 0.20 R -38 R -30 R 1 5 R -1 5 R -10 R-30 R -10 11 1 5% 0.40 0.58 0.20 R -38 R -30 R -21 R -21 R -1 O R -30 R -10 III 15% 0.40 0.55 0.20 R -35/ R -30/ R -21 / R -15 R-1 0 R -301 R -10 Group R- I and R -2 U =0.03 I U =0.034 U =0.060 U=0.029 Occupancy Only IV Unlimited 0.40 0.58 0.20 R -38 R -30 R -21 R -2 i R -1 O R -30 R -1 O Group R -3 and R -4 Occupancy Only V Unlimited 0.35 0.58 0.20 R -38/ R -301 R -21 / R -15 R -1 O R -301 R- I O Group R -1 and R -2 U =0.031 U=0.034 U =0.060 U =0.029 Occupancy Only 7 FLOOR FLAN NOTES - continued 26. SPECIAL STAIRWAYS: IRC R3 I 1 .5.3.2, R3 i I .5.8. 1 . Circular stairways, spiral stairways, winders and bulkhead enclosure stairways shall comply with all requirements of stairways except: Winder treads shall have a minimum tread depth of 1 0" measured at a point 12" from the side where the treads are narrower. Winder treads shall have a minimum tread depth of G" at any point. Siral stairways are permitted, provided the minimum width shall be 26 inches (G6Omm) with each tread having a 7 %2' minimum tread depth at 1 2" from the narrower edge. All treads shall be identical, and the rise shall be no more than 9 %2 ". A minimum headroom of 6 feet G inches shall be provided. Unless demonstrated otherwise soil bearing capacity is assumed to be 1 500 psf, weathering potential is determined to be moderate (IRC Table 30 i .2(i )). STRUCTURAL NOTES 27. FOUNDATION FOOTING 51ZE: IRC Section R403. Assume load bearing value of soil 1 500 psf unless proven otherwise. - Supporting i floor: minimum G "x 12 ". - Supporting 2 floors: minimum G "x 1 5 ". - Supporting 3 floors: minimum 8 "x23 ". Spread footing projections shall be at least 2" * shall not exceed the thickness of the footing. 28. FOOTING REINFORCEMENT: iRC Section 8403, R.404. i .4. Plain concrete walls located in Seismic Design Categories DI and D2 shall comply with the following: I ) Minimum reinforcement shall consist of one #4 horizontal bar located in the upper i 2" of the wall. 2) Wall height shall not exceed 8'. 3) height of unbalanced backfill shall not exceed 4'. 4) A minimum thickness of 7 %2' is required for plain concrete foundation walls except that a minimum thickness of G" shall be permitted for plain concrete foundation walls with a max. height of 4'6" provided the minimum specified compressive strength of concrete, fc, is 4000 psi as evidenced by the delivery (batch) ticket for the project. As a minimum standard, refer to the attached handouts: foundation Reinforcement Requirements. 29. FOUNDATION WALL SIZE: IRC Tables 8404. 1 . 1(1), 8404.1 . J (2), R404. 1 . J (3), R404. 1 . I (4), $ Section 404. I .4. See attached handouts. Plain concrete and plain masonry foundation walls located in Seismic Design Categories D I and D2, as established in Table R30 1 . 1(1), shall comply with the following: J) Minimum reinforcement shall consist of one #4 horizontal bar located in the upper 1 2" of the wall. 2) Wall height shall not exceed 8'. 3) Height of unbalanced backfill shall not exceed 4'O ". 4) A minimum thickness of 7%2" is required for plain concrete foundation walls except that a minimum thickness of 6" shall be permitted for plain concrete foundation walls except that a minimum thicknes of 6" shall be permitted for plain concrete foundation walls with a maximum height of 4'G ". 5) Main masonry foundation walls shall be a minimum of 8" thick. Vertical reinforcement for masonry stem walls shall be tied to the horizontal reinforcement in the footings. Masonry stem walls located in Seismic Design Categories DI and D2 shall have a min. vertical reinforcement of one #3 bar located at max. of 4' o.c. in grouted cells. Foundation walls located Seismic Design Categories D I and D2, as established in Table R30 I .2(1), supporting more than 4' of backfill or exceeding 8' in height shall be constructed in accordance with Table R404.1 .(2), R404. i . i (3) or R404. I . I (4) [reinforced concrete] and shall have two #4 horizontal bars located in the upper I 2" of the wall. 30. STEPPED FOUNDATIONS: IRC Section 602.1 I .3. Where stepped foundations occur, the following requirements apply: 1) Where the height of a required braced wall panel that extends from the foundation to floor above varies more than 4', the braced wall panel shall be constructed in accordance to figure RG02. I I .3. See attached details. 2) Where the lowest floor framing rests directly on a sill bolted to a foundation not less than 8' in length along a line of bracing, the line shall be considered as braced. The double plate of the cripple stud wall beyond the segment of footing that extends to the lowest framed floor shall be spliced by extending the upper top plate at a minimum of 4' along the foundation. Anchor bolts shall be located a max. of 1' and 3' from the step foundation. 3) Where cripple walls occur between the top of the foundation and the lowest floor framing, the bracing requirements for a story shall apply. 4) Where only the bottom of the foundation is stepped and the lowest floor framing rests directly on a sill bolted to the foundations, the requirements of Section R602. 1 I . 1 shall apply. 31 . FOOTING DEPTH: IRC Section R403. 1 .4, R403. 1 .4.2. All exterior footings shall be placed at least 1 2" below undisturbed ground. Interior footings supporting bearing or bracing walls and cast monolithically with a slab on grade shall extend to a depth of less than I 2" below the top of slab. STRUCTURAL NOTES - continued 32. CRIPPLE WALL BRACING: IRC Definition, Sections R602. 10.2, RG02. 10.2.3, $ R602. 10. I I . 1 *. R.G02. 1 0. 1 I .2. A cripple wall is a framed wall from the top foundation to the underside of the floor framing of the first story above grade plane. In Seismic category DI (other than D2), cripple walls shall be braced with an amount and type of bracing as required for the wall above in accordance with Table R602. 10. 1 with the following modifications for cripple wall bracing: i ) The percent bracing amount as determined from Table R602. 10. I shall be increased by 15 %, and 2) The wall panel spacing shall be decreased to 18' instead of 25'. In Seismic Design Category D2, cripple walls shall be braced in accordance with Table RG02. 10.1 . In any Seismic Design Category, cripple walls are permitted to be redesignated as the first story walls for purposes of determining wall bracing requirements. If the cripple walls are redesignated, the stories above the redesignated story shall be counted as the second and third stories respectively. Where interior braced wall lines occur without a continuous foundation below, the length of parallel exterior cripple wall bracing shall be I %2 times the length required by Table RG02. 10. 1 . Where cripple walls are braced using method 3 of Section 8602. 1 0.3. (wood structural panel) cannot provide this additional length, the capacity of the sheathing shall be increased by reducing the spacing of fasteners along the perimeter of each piece of sheathing to 4" o.c. Adhesive attachment of wall sheathing shall not be permitted in Seismic Design Catergories DI and D2. 33. UNDER -FLOOR VENTILATION: IRC Section 408. 1 and 408.2. The under -floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement or cellar) shall be provided with ventilation openings through foundation walls or exterior walls having a net area of not less than I square foot for each 150 square feet of under -floor space area. Openings shall be located as close to corners as practical and shall provided cross - ventilation. One such opening shall be within 3 -feet of each corner of the building. Ventilation openings shall be covered for their height and width with any of the following materials provided that the least dimension of the covering shall not exceed Y4": 1 Perforated sheet metal plates not less than .070" thick, 2) Expanded sheet metal plates not less than .047" thick, 3) Cast iron grills or grating, 4) Extruded load- bearing brick vents, 5) hardware cloth of .035" wire or heavier, G) Corrosion resistant wire mesh, with the least dimension being % ". See exceptions for additional options. 34. UNDER -FLOOR ACCESS: IRC Section 408.4. Access shall be provided to all under -floor spaces. Access openings through the floor shall be a minimum of 1 8" x 24 ". Openings through a perimeter wall shall be at least 1G" x 24 ". When any portion of the through wall access is below grade, an areaway of not less than I G" x 24" shall be provided. The bottom of the areaway shall be below the threshold of the access opening. Through wall access openings shall not be located under a door to the residence. Unobstructed by pipes, ducts or similar construction. 35. DECKS $ EXTERIOR STAIRS: IRC Section 3 19. I .2. Based upon climate conditions and local exposure approved naturally durable or pressure preservatively treated wood shall be used for those portions of wood members that form the structural supports of buildings, balconies, porches, or similar permanent building appurtenances. Such members may include: 1) Horizontal members such as girders, joists, and decking. 2) Vertical members such as posts, poles and columns. 3) Both horizontal and vertical members. Treatment must be applied by manufacturer. ENERGY CODE GENERAL NOTES 36. PREMISE IDENTIFICATION: IRC Definition, Section R32 I $ City of Seatac Standards for Fire Apparatus Access Roads. Approved numbers or addresses sahll be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Approved numbers or addresses shall be placed on all new commercial or residential buildings (that require an address), at the beginning of long driveways when the address is not clearly visible from the access road, or in any other areas deemed necessary by the City of Seatac Fire Marshal. They shall be placed in such a position as to be plainly visible and legible from the street or road fronting the property. Said numbers shall contrast with their background. 37. APPROVED PLANS: IBC Sections 1 06.4. I , i 06.4.2. The approved plans shall not be modified, changed or altered without authorization from the Building Official. The building permit and one (1) set of approved plans for the project shall be kept at the site of work and shall be open to inspection by the building official or his or her authorized representative. 38. HEATING: IRC Section 303.8. Every dwelling unit shall be provided with heating facilities capable of maintaining a minimum room temperature of G8° F at a point 3' above the floor and 2' from exterior walls in all habitable rooms at the design temperature. The installation of portable heaters shall not be used to achieve compliance with this section. 39. GYPSUM WALLBOARD: IRC Section 8702.4.2 * R702.4.3. When gypsum is used as a base or backer for adhesive application of ceramic tile or other nonabsorbent material, it shall conform with ASTM C630 or CI 1 78. Water resistant gypsum backing board shall be permitted to be used on ceilings where framing spacing does not exceed I 2" o.c. for % thick or I G" o.c. for 5/8" thick gypsum board. Water resistant gypsum backing board shall not be installed over a vapor retarder, or on ceilings in a shower or tub compartment. All cut or exposed edges, including those at wall intersections, shall be sealed as recommended by the manufacturer. Limitations: Water resistant gypsum backing board shall not be used in the following locations: 1) Over a vapor retarder in a shower or bathtub compartment. 2) Where theire will be direct exposure to water, or in areas subject to continuous high humidity. 40. GYPSUM WALLBOARD FASTENING: 1RC 8702.3.6 $ Table R702.3.2, IBC 2306.5. I .4. Screws for attaching gypsum board to wood framing shall be Type -W or Type 5 in accordance with ASTM C 1 002 and shall penetrate the wood not less than 5/8 ". Footnote, Table R702.35: Type X gypsum wallboard for garage ceilings beneath habitable rooms shall be installed perpendicular to the ceiling framing and shall be fastened at G" o.c. by minimum 1 -7/8" Gd coated nails or equivalent drywall screws. -3/8" minimum from edge and ends for nails or screws. - fastening (nails): 7" o.c. max. ceiling, 8" walls. - Fastening (screws): 1 2" o.c. ceiling, 1G" o.c. walls when wall framing is 16" o.c., I 2" when wall framing is 24" o.c. 4 I . STORY / STORY ABOVE GRADE: IRC Section R202. That portion of a building included between the upper surface of a floor and the upper surface of the floor or roof next above. A story above grade is any story having its finished floor surface entirely above grade, except that a basement shall be considered as a story above grade where the finished surface of the floor above the basement is: I) More than G' above grade plane. 2) More than 6' above the finished ground level for more than 50 % of the total building perimeter. 3) More than 1 2' above the finished ground at any level. 42. HEIGHT Of BUILDING GRADE PLANE: IRC Section R202. The vertical distance from grade plane to the average height of the highest roof surface. The grade plane : A reference plane representing the average of the finished ground level adjoining the building at all exterior walls. Where the finished ground level slopes away from the exterior walls, the reference plane shall be established by the lowest points within the area between the building and the lot line or, where the lot line is more than G' from the building between the structure and a point 6' from the building. Note: Zoning regulations may limit the height of residential structures more stringently. Check with your local jurisdiction for height limitations. Ce.9 Nap t MCA kl _ -A 43. RETAINING WALLS: IBC Section R 1 806. I , IRC Section R 105.2. Retaining walls shall be designed to ensure stability against overturning, sliding, excessive foundation pressure and water uplift. Retaining walls shall be designed for a safety factor of I .5 against lateral sliding and overturning. Retaining walls that are not over 4' in height measured from the bottom for the footing to the top of the wall not supporting a surcharge is exempt from permits. c` (PIRES: 4/24/ 0 7 PROPOSED RESIDENCE FOR SIDHU HOMES INC. LOT 1 -B, 46XX SO. 148TH ST. TUKWILA, WA. RECEIVED CITY OF TUKWILA OCT 1 0 /IHI/ PERMIT CENTER