Loading...
HomeMy WebLinkAboutPermit D07-429 - WESTFIELD SOUTHCENTER MALL - SWAROVSKI - STORAGE RACKSSWAROVSKI 636 SOUThCENTER MALL D07 -429 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: Contact Person: Name: Address: Phone: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 636 SOUTHCENTER MALL TUKW SWAROVSKI XXX SOUTHCENTER MALL, STE 1123 , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 MARY ANN ARTAVIA 3854 MENTONE AV #6 , CULVER CITY CA 90232 Contractor: Name: WESTWOOD CONTRACTORS INC. Address: 200 S 333RD ST #244 , FEDERAL WAY WA 98003 Phone: 206 661 -0800 Contractor License No: WESTWCI088BF DESCRIPTION OF WORK: INSTALLATION OF STORAGE RACKS Value of Construction: $0.00 Type of Fire Protection: SPRINKLER/AFA Type of Construction: IIB DEVELOPMENT PERMIT * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 09/11/2008 Fees Collected: International Building Code Edition: Occupancy per IBC: D07 -429 02/04/2008 08/02/2008 $231.84 2006 0019 doc: IBC-10/06 007 -429 Printed: 02 -04 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of construction or Signatur Print Name: doc: IBC -10/06 City ov.Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating work. I am authorized to sign and obtain this development permit. Date: it ht. � to As kat_ c?„,i, s tir Private: Public: Permit Number: D07 -429 Issue Date: 02/04/2008 Permit Expires On: 08/02/2008 Date: ' 1 - This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -429 Printed: 02 -04 -2008 Parcel No.: 6364200010 Address: 636 SOUTHCENTER MALL TUKW Suite No: Tenant: SWAROVSKI 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** Permit Number: D07 - 429 Status: ISSUED Applied Date: 11/21/2007 Issue Date: 02/04/2008 doc: Cond -10/06 D07 -429 Printed: 02 -04 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the 40•01- ce of work. Signature: Date: Print Name: I ' 'lti5r% if ordinances governing or local laws regulating doc: Cond -10/06 D07 -429 Printed: 02 - 04 - 2008 Site Address: Tenant Name: CITY OF TUKWIL Community Developmerirbepartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** (3 Sou C6tvi 2 P -cv y. SU/ 0 vs•kCX King Co Assessor's Tax No.: 06104 Suite Number: Tl �3 Floor: New Tenant: E.... Yes ❑ ..No Property Owners Name: GJ) S t Fi i—O 5 Pogd -rj ra „ Mailing Address: /)(, L I ShFI►2�. 61-VD, //fii FI/L, Lof �'l4ut , (L,4 c700 25 State Zip City CONTACT PERSON - who do we contact when your permit is ready to be issue Name: A l /4 4-77OI VW( 64.71 IT �112Oca Mailin 214 1 ��� 1 , 4 1 6t/7�OW £ 4/lE 0 6 g E -Mail Address: fl ZJ ya-nn Q 44,enwi yLztru, Cor Company Name: T13� Day Telephone: 3/ '" ' 7( "/1W Ca itc, C ry CA--- 90 232 City State Zip Fax Number: 3 / 0 -(76 - - 0 / GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Mailing Address: City Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: Contact Person: E -Mail Address: ARCHITECT OF RECORD - All plans must be wet stamped by Architect ofRecord % Company Name: N/1/4// S 1 ? ' l l TT/tl --L Aleme8 / 4 Mailing Address: 60 3 I 1-2-6 (4) e-- - e T ST J- o City Contact Person: J)t n/l./ S L ,I�, Day Telephone: E -Mail Address: !)71 4 ratty F'QT/11 rry c�4JP,e4 N CO ax Number: ENGINEER OF RECORD - All plans must be Wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: �cr rre /l) • Cv4sE Q: Appliations\Fonns- Applications On Line\3 -2106 - Permit Application.doc Revised: 9 -2006 bh State T 760 7 Zip e s ' -- �y Stat 5 X - yam? -7 3 7 7 City Day Telephone: Fax Number: State Zip Zip Page 1 of 6 Valuation of Project (contractor's bid price): $ 0 02) Existing Building Valuation: $ g g Scope of Work (please provide detailed information): Will there be new rack storage? [ .... Yes ❑.. No If yes, a separate- permit and plan submittal will be required. Provide All Building Areas to Square Footage :Belo v PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence: Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: IT/ Sprinklers co - Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes riK No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Fixture Type: Qty _Fixture Type: Qty Fixture Type:: Qty . Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPIN `ERMIT INFORMATION - 206 - 43.67 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Q:'tApplications\Forms- Applications On Lined -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Page 5 of 6 I Date Application Accepted: ii i,71 k Illl Date Application Expires: v .( r G g Staff Initial I M — 7 1 ( 1--) RMIT:APPLICATION NOT Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN AUTHORIZED G NT: Signature: Print Name: ✓z%u4E �/ Day Telephone: 26 Mailing Address: 50 3 '1 / 7 Mt .fit j � T' 3371 Zip Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Date: /c) 7 State Page 6 of 6 Receipt No.: R08 -00290 Payee: WESTWOOD CONTRACTORS TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description doc: Receipt -06 BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: D07 -429 Address: 636 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/21/2007 Applicant: SWAROVSKI Issue Date: Initials: WER Payment Date: 02/04/2008 09:22 AM User ID: 1655 Balance: $0.00 Amount Payment Check 143151 142.28 Account Code Current Pmts 000/322.100 137.78 000/386.904 4.50 Total: $142.28 Payment Amount: $142.28 8029 02/04 9710 TOTAL 1998.20 Printed: 02 -04 -2008 RECEIPT NO: R07 -02566 Initials: User ID: JEM 1165 Payee: NATIONWIDE PERMIT CONSULTANTS SET ID: 1121 SET NAME: SWAROVSKI SET TRANSACTIONS: Set Member Amount City of Tukwila epartment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us D07 -428 958.67 D07 -429 89.56 EL07 -709 77.90 M07 -252 57.14 PG07 -311 27.00 TOTAL: 1,210.27 TRANSACTION LIST: Type Method Description Amount Payment Check 363 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: 000.345.832.00.0 77.90 000/345.830 1,132.37 TOTAL: 1,210.27 Payment Date: 11/21/2007 Total Payment: 1,210.27 1,210.27 1,210.27 Account Code Current Pmts 5341 11/26 9710 TOTAL 1210.27 Project: f SuJal'0 Type of Inspection: / ti ll l `' Address: // 36 � Date Called: Special Instructions: Date Wanted: 7434 e a.m. P.m. Requester: Phone No: INSPECTION RECORD t,,.' J7 Retain a copy with permit 1 - y INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Q OM M ENTS: p Approved per applicable codes. El Corrections required prior to approval. 'Inspector: El $60.00 paid at SPECTION FEE REQUIRED. Prior to inspection, fee must be 00 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: r .� 'Date: 7/Z 3� Project: Sc � „�— Type of Inspection: j" 7 '4/6 Address: 6.7L— 49/9 // Date Called: Special Instructions: Date Wanted: rn, Requester: Phone No: INSPECTION RECORD Retain a copy with permit 1) 0 7 y79 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: I Dat o .00 REINSPECTIOJI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southc ter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: !Date: COMMENTS: Type of nspection: g k, k EM r o L i (, 5 t° - �'. at) 4 Address: (L 6 s . . l v\ r'rt -L..... Suite #: w PNAc 1e o k. Special Instructions: Pre -Fire: Phone No.: 9 1- 7 - 79 '1 — l `(7 Occupancy Type: Seg ∎iok t.eit Si ik,o, L. e7... A T L c,c_ . gg rr:wo L !7t€. Project: SIOA VSk r Type of nspection: g k, k EM r o L i (, 5 t° - �'. at) 4 Address: (L 6 s . . l v\ r'rt -L..... Suite #: w Contact Person: C-e fc.) -e.. Rik) c a Special Instructions: Pre -Fire: Phone No.: 9 1- 7 - 79 '1 — l `(7 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East. Tukwila, Wa. 98188 I NIQUIproved per applicable codes. INSPECTION RECORD Retain a copy with permit H � K - S - 060 PERMIT NUMBERS 206 - 575 -4407 ci � - � � PA 1 Corrections required prior to approval. Inspector: Date: '�/ / e Hrs.: / GL /Li $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 SQUARE FOOTAGE DESIGN CONSULTANTS ifica SO. FT. A SALES AREA (W/ STOREFRONT) 621 B STOCKROOM (W/ WASHROOM) 486 TOTAL NET SQUARE FOOTAGE 1101 TOTAL RENTED AREA TO LEASE LINE 1201 ADJACENT TENANT REVIEWED FOR CODE COMPLIANCE APPROVED DEC -- 720o7 Cy Of Tukwila B IL!IN D. ION SERVICE SINK LEASE LINE DIMENSION ADJACENT TENANT ADJACENT TENANT 7O LEASE LINE DIMENSION W]*11.111 1111 I 1111111 •••� \ / MIRROR AM- 14DURA h AM- 221HC1 AM- 14DURA AM-14 DURA 0-95 AM- 14-0URA FILE COPY_ Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation . : >' adopted code or ordinance. Receipt of app /� ooncttior>e is adcrtowled98d• 1n AM -21B AIr -21B AM-218 AM-215 AMA �, \ AMA AM City of Tukwila BUILDING DIVISION r j i 1 MALL 11 LEASE LINE CLOSURE LINE RECEIVEG DEC 0 7 2007 PERMIT CENTER REVISIONS T , . , <<, No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. DESIGN CONSULTANTS ifica PROJECT SOIITHCENTER MALL TUKWILA.WA DRAWING FIXTURE PLAN REV. DATE 00 10-25 -2007 01 PAGE P1 E B SWA O T 514. 844.6611 SCALE DRAWN BY 02 F 514.844 -7646 3/16" = 1' -0" K.J. 03 ADJACENT TENANT REVIEWED FOR CODE COMPLIANCE APPROVED DEC -- 720o7 Cy Of Tukwila B IL!IN D. ION SERVICE SINK LEASE LINE DIMENSION ADJACENT TENANT ADJACENT TENANT 7O LEASE LINE DIMENSION W]*11.111 1111 I 1111111 •••� \ / MIRROR AM- 14DURA h AM- 221HC1 AM- 14DURA AM-14 DURA 0-95 AM- 14-0URA FILE COPY_ Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation . : >' adopted code or ordinance. Receipt of app /� ooncttior>e is adcrtowled98d• 1n AM -21B AIr -21B AM-218 AM-215 AMA �, \ AMA AM City of Tukwila BUILDING DIVISION r j i 1 MALL 11 LEASE LINE CLOSURE LINE RECEIVEG DEC 0 7 2007 PERMIT CENTER REVISIONS T , . , <<, No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. J' SQUARE FOOT PLATE FOR HI-R1SE SHELVING MODEL# HRFPZ BY METRO SHELVING. FIXED l-1/ 5 RAMSET u 1505 SHOT PINS STOCKROOM SHELVING SHGI SHG -2' 5' -0" x I' -2" WIRE SHELVING SHELV -SOI 14%86"X86" SHELVING SHELV - POI 4 I' -2" WIRE SHELVING SHELV -502 LABEL HOLDERS (4 PER SHELF PROVIDED) TO BE INSTALLED BY SWAROVSKI DURING SETUP WHEN ROOM 15 NOT AVAILABLE NEXT TO DESK FILE CABINET TO BE PLACED UNDER SHELVING UNIT NEAREST DESK 4' -0" x 1' -2" WIRE SHELVING SHELV -E02 14"X46%86" SHELVING SHELV-P02 WATERFALL COAT HANGER ADDED TO LAST SET OF SHELVING IN ROW N N N \ \ \ DSK1 4' -0" x 2' -0" MANAGERS DESK DESK -EOI 5' -0" x I' -2" SEE FIGURE 6 • 5P2 WIRE SHELVING SHELV-S01 MANAGER DESK DESK -POI SAFE BOLTED TO FLOOR LEFT SIDE OF DESK I 2"-O" 4' -0" x 2' -0" MANAGER'S DESK DESK -501 1 , -6 " LCK 1 '-0 1/4" x I -6" 1'-0 1/4" x 1 NOTE: LOCKER UNIT LOCKER UNIT GABLES, WALLPLATE, LCK_EOI LCK_SOI JACKS AND TERMINATIONS PROVIDED AND INSTALLED BY SWAROVSKI LCK_POI NOTE: G.G. TO SECURE ALL STOCKROOM SHELVING ON WALL AND FLOOR WITH THE PROVIDED BRACKETS. iECEIVED DEC 07 2007 PERMIT CENTER 4 ADegenkolb November 8, 2007 Ms. Mirella Matera £difica Architecture + Design 4521, rue Clark Montreal, QC H2T 2T3 Reference: Swarovski Southcenter Mall — Shelving Unit Anchorage Tukwila, Washington [Degenkolb Job Number A7508027.00) Dear Ms. Matera: Attached are the structural calculations, numbered 1— 27, and Details SSK -01 and SSK- 02 for the anchorage of the four shelving units and a manager's desk in the above referenced project. The anchorage design was performed in accordance with the 2006 Edition of the International Building Code with State of Washington amendments. If you have any questions, please do not hesitate t Very truly yours, DEGENKOLB ENGINEERS C REVIEWED FOR CODE COMPLIANCE APPROVED DEC - 7 2007 Cale Ash Design Engin • City Of Tukwila LDIN DIVISION 0 9 NOV. 2087 DG/ca drachmas: Anchorage F. rpnojea. A0ASOM /175011027.00\Cort1Q#W71107doc Swarovski Soudicakc anchorage design oaks cover.doc EXPIRES 6/6/01 David Gonzalez Associate Principal RECEIVED CITY OF TUKWILA NOV 21 2007 PERMIT CENTER San Francisco Los Angeles Portland Oakland San Diego Seattle 720 W F Degen Engineers � O N 600 University Street Seattle, Washington 98101 O 262.9240 phone N 262.9346 fax Ak_lgenkolb Notes: 1. Anchorage designed for Super Erecta Shelving (SES) unit and manager's desk as manufactured by InterMetro Industries. Floor plates and anchors shall be installed at each of the four legs of each unit. 2. At adjoining shelving units, a SASES50BP -1 base plate with 4 -3/8" dia. Hilti TZ anchors (3" embed) may be substituted for (2) SASES25BP -1 base plates. 3. The anchorage is designed for a maximum shelf storage load of 50 psf. 4. Expansion anchors shall be Hilti TZ installed per ICBO ESR -1917 with a minimum effective embedment depth of 3 inches. Any substutions shall have an equivalent ICBO rated load value. 5. Special inspection of expansion anchor installation is required in accordance with IBC Section 1704. Shelving and Manager's Desk Base Anchorage Detail Degenkolb Engineers 600 University Street, Suite 720 Seattle, WA 98101 Phone: 206.262.9240 Fax: 206.262.9346 'I SA�rE Z55$f',4• 15 ; c1 r> E Yt�ire` M14 4/1- IL ANC— (8) Ca _111 viv. SHG2 4 x I =2° YLIRE SHELVING SF+ELV -E02 IL • a. to Title: Shelf/Desk Base Anchorage Detail Swarovski — Southcenter Mall Drawn: CA Job No.: A7508027 S S K- 01 Design: CA Rev.: CA Rev.: 0 Check: DG Date: 11/7/07 Job: Swarovski Shelving Anchorage Page 1 of 1 Sheet Number - "TAIL- A A Degenkolb Degenkolb Engineers 600 University Street, Suite 720 Seattle, WA 98101 Phone: 206.262.9240 Fax: 206.262.9346 ()tUl 5rptvr ri Cf4ANINAL Isji 2 - :f f 5; —p. ', `ja 7, y - t47r (I; Lam �- - A4 . : *K- '44 t; 1 I LU... ■I...... ■111 iiiiraill u..••■• 1••••••• IMEMOMII DSKI 4' -0 4L0' x 2'-O" MANASER DeSK DDK -t=01 SEE FI6URJ= 6 c 51 Title: Desk Shelf Anchorage Detail Swarovski — Southcenter Mall Drawn: CA Job No.: A7508027 Design: CA Rev.: 0 Check: DG Date: 11/7/07 Job: Swarovski Shelving Anchorage SAM SoLTED TO I LOOK LEFT SIDE OF DESK Notes: 1. Anchorage designed for Super Erecta Shelving (SES) manager's desk as manufactured by InterMetro Industries. Floor plates and anchors shall be installed at each of the four desk legs per SSK -01. 2. The anchorage is designed for a maximum shelf storage load of 50 psf. Manager's Desk Shelf Wall Anchorage Detail Sheet Number SSK- 02 Page 1 of 1 DegenkoIb Subject AA) C Job: 9 —01/K.1 l U& 7-0- 1(:Ll)1p2 O grGt -r J� PC914l•- C,Z rre 14 Job Number. Ai 0 r0 Z '7-00 By. CA Section: Checked By Page ) of VP. A) 1 C Y/L- r & S+�r,Z -I/ »il U/JiT Am> at ik &e6 Lo cA r ,r cry c AA)C kc E 1 o '4 &Ai, r Z 6 l C. ttil )c VA) T r 4 -6 Ur ctL urz_ cry hrU ( A ' A,JUi A (1 uiL..t7 • i /f i'—j 1 �i1(G ►�� Cu?n. Col = ZooG IBC AwfcE ✓% G ;3 y otr►? -4C !'J OA rei Tr A ci — t E Gi rr Ct 7 �7 0 ccvtAn) C y Ga >✓7c�y L 5r Date: C _� = 1_ 0 ra_ Act 7-oS § 13.1. (.5;4r7 1.0417 G ✓UL _ <Iti LA"- e' Lam✓ - 50 reg. 9f-lc;1.c,( Project Name = Swarovski Southcenter Date = Tue Nov 06 16:04:32 PST 2007 Conterminous 48 States 2005 ASCE 7 Standard Zip Code = 98188 Spectra! Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Centroid Sa (sec) (g) 0.2 1.429 Ss, Site Class B 1.0 0.489 S1, Site Class B Period Maximum Sa (sec) (g) 0.2 1.473 Ss, Site Class B 1.0 0.507 S1, Site Class B Period Minimum Sa (sec) (g) 0.2 1.377 Ss, Site Class B 1.0 0.470 S1, Site Class B Conterminous 48 States 2005 ASCE 7 Standard Zip Code = 98188 Spectral Response Accelerations SMs and SM1 SMs = FaSs and SM1 = FvS1 Site Class D- Fa = 1.0 ,Fv = 1.511 Period Sa (sec) (g) 0.2 1 .429 SMs, Site Class D 1.0 0.739 SM1, Site Class D Conterminous 48 States 2005 ASCE 7 Standard Zip Code = 98188 Z • Site Class D - Fa =1.0 ,Fv =1.511 Period Sa (sec) (g) 0.2 0.952 SDs, Site Class D 1.0 0.493 SDI, Site Class D 4genkoIb Subject S+ 1ti1 Gtice -Ag r Job: 9 LAV-D I1 * G !t! trTfit ( 517 -1'c nt■J 1 c.4.6 - ' A t7 7-05 § fi / ` r-, s = 0.9 9 P C K ti; LE (cam- Pcd\A J,- +.1 • T y r LDL .P- 4 5 rrr Z¢7' t. C' 11 g j NLcc Z By: to F = 6.635"ki Cervreer s ��..�.� 0,3Svs=P1-4 0. Z UP 1,0 6.Z 9 1.)Y Job Number. A s0 Z - T oO Checked By: 1 Page of L /, b s us = r U P Date: t I/6 o ff Section: O. 6 ;S ± 0. tq O ) (. A4P Ca^ 1 1 j 1 F;17._ ' riZ c9US'P- 17 I A): 0.q V -r I- of ADegenkolb Subject: 54-/ L r 4i c 14 e14 4 4 Job: 9 Lizigoti c) jotr-FfcovreiL. �ut;Ll/rNy - ly ''x Kd x L1'rre-i\1 96 ( ! `/ "X 56 ?b .. ' tCLF >4NCti l-A r 5. - iL44j T J L " 3 ; a 4 x(1t' x 70 vy r; IO 0..t Li -: so y-( /»-tLV x (y )( I ,1.1 x S u alit; I(67 Pb U I I -704 �J' 4 = 11 Z x jy Job Number. A 7 cp $" Z o 0 By: Checked By: LJ Page of C' (r z o„b) = go 6,e La- s&u ± 0.19(rZio,eb)= fi Zyr ,Q,,- Vi Othizs f'- ^- •= c x 4.5 = 5 6 Z7Ab g_tr ,cfrr u4 = 0,1 (IZ7o.Qb )c 7 ") _ 6,6 jb - --1 n. tit fr o, b,Q - O ( 123& { 5t1")= ZZ ' J1- 4 0,17c Ave Aivc-fic,c /1i q U= isD6Jb /q =ZoZJb x 1-3 ► =,acrq = z6ZJ& !Om : L Ac-r /'cQuitip Rae Ac t= 7- OS § 15.1-7- T2 y 5/1 ZS *P- E PL - ru of Z Yff ;.. L ri -rtj� z ,eltd " Section: Z v Lib y 13 Z' Jb x 1/= z c,z0 u —f- : riy - 7.247 A►vc ArE or- - SSE ►vE'x'f 1P.ai*t 4 Date: [,/6 / r. = 17Z7 imill , �` Iles Company: per, ti1J1�L'5 Sheet 1 of 4 Specifier. G A Project 9 L-44¢ U / . i �lo rr vv L User application PROFIS Anchor 1.8.0 Address Contract No.: A75pcf6Z Phone /Fax: - / - Responsible: http / /www.ushilti.com/ E-Mail: Location/Date: - / 11/7/2007 Specifier's comments: Anchor type and size: Kwik Bolt - Tensile Zone (KB -1Z)3/8 (2) Effective embedment depth: h 2.00 in. Material: Carbon Steel Proof: desgn method: AQ 318 / AC 193 Stand-off installation: e = 0.00 in. (no standoff); t = 0.25 in. Anchor plate: CUSTOM; f„,= 36000 psi; ; I, x l x t = 7.00 x 2.87 x 0.25 in. Base material: uncracled concrete 2500, f = 2500 pd; h = 5.00 in. Reinforcement condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Anchor Geometry fin.1 plan view y section A t =.2 h z x °o x c I, =7.00 o r• 0L C6C 0 1 2 a) action B z y h =5.00 393.70 5.00 393.70 ` section A 4 y 2.8 Laming Governing loads[lb, in.-lb) N = 1730 V = 262 Governing loads[fb, in.-lb] N 1730 M = 0 M = 0 V, 262 z V 262 y M, 0 0 M 0 z__1 M, x Eccentricity (structural section) [in.) e, = 0.00; e, =0.00 Seismic loads yes V = 262 M =0 Input data and results must be checked tor agreement with the misting conditions and torplausibilityl PROFIS Anchor (c ) 2003 Hilti AG, FL -9494 Schaan Hilti Is a registered Trademaik of HIM AG, Schaan 11 User application PROFIS Anchor 1.8.0 ��CA of 4 Specifier. Project: '71.)Af2_0'► ( 70 +f L1; - Address Contract No.: A15 7- 00 Phone/Fax - / - ReTonsble: http://wvwv.ushilti.com/ E -Mail: Location/Date: - / 11/7/2007 Load case (governing): Anchor reactions [1b] Tenson force: ( +Tenson -Pressure) Tenson 1 1R 2 Anchor Tenson force Shear force 1 2 865 865 185 185 max concrete compressive strain [%c]: 0.00 max concrete compressive stress [pd]: 0 resulting tendon force [lb]: 1730 resulting compression force [lb]: 0 Tension load Dedgn values[Ib] Proof Load N Strength A Utilization YN [ %1= N„ /4N Status Steel failure 865 3649 24 OK Pull-out failure 865 1107 78 OK Concrete cone failure 1730 2149 81 OK Steel failure Nsa[Ib] $ $seismic d a [Ib1 It[lb] 6487 0.750 0.750 3649 865 Pull-out failure NRkp[Ib] (f ° ' S $ $seismic 4N:pn[lb] It[lb] 2270 1.000 0.650 0.750 1107 865 Concrete cone failure ANn[in A c[in.] Ccr.ep[in.) 66.00 36.00 393.70 4.00 Wect,N Wec2,N Wed,N Wedge I I(cr 1.0 00 1.000 1.000 • 1.000 17 'b[Ib] 0 •seismic 7 $Nog[Ib] 1 N„a[Ib] 2404 0.650 0.750 2149 1730 Shear load Dedgn values[lb] Proof Load V„ Strength 4iV Utilization [i [ %] = V /$V Status Steel failure 185 1246 15 OK Pryout failure 185 1157 16 OK Steel failure Vsa[Ib] 4) ()seismic $t[lb] Vu 2555 0.650 0.750 1246 185 Input data and results must be checked for agreement with the refuting conditions and for plausibility) PROFIS Anchor (c ) 2003 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan P , User application PROFIS Anchor 1.8.0 Company: *J'ti`�1ti,1VY -OL Sheet 3 of 4 Specifier. GA Project ..JA,2 4 y f 99o iYL Address Contract No.: roz,"7.00 Phone/Fax: - / - Responsble: http://www.ushilti.00m/ E -Mail: Location/Date: -/ 11/7/2007 Pryout failure ANc[m e 1 A .,27 ANCO[)n J kp 66.00 36.00 1.000 Wed,N Wect,N Wec2,N Wedge kr 1.000 1.000 1.000 1.000 17 N • .seismic 0V� V 2404 0.700 0.750 1157 185 Combined tension and shear loads YN = NU /$Nn [f = V„ /4tV Utilization f N,V [ %] Status 0.805 0.160 5/3 74 OK p p p NV= YN RR +l pp =1or NNV =(1+N +i V )/1.2< =1 Allowable Stress Design (Refer. ICC-ESR) anchor group relevant (tension) single anchor relevant (shear) Reference for load Tendon [lb] Shear [Ib] including seismic excluding seismic induding seismic excluding seismic ACI318 Section D.4.4 1953 - 1052 - AC1318 Section D.4.5 1791 - 964 - R allow,ASD = R d / a TTTall°w.ASD + VNallow,ASD <= 1.2 Proof of the transmission of the anchor loads to the supports Transmission of the anchor loads into the concrete Checking the bander of loads into the base material is required in accordance with ACI 318! Shear ressance of base material Shear resistance of the base material must be checked according to relevant approval ordandard! Warnings Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applieswhere such supplementary reinforcement is not provided, or where pullout or pryout strength governs Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility' PROFIS Anchor (c ) 2003 Hilti AG, F1_4494 Schaan Hitti is a registered Trademark of Milli AS Schoen -3.50 1.44 3.50 -1.44 3.50 1.44 I -3.50 -1.44 1 W."!" I User application PROFIS Anchor 1.8.0 http://www.ushilti.00m/ Company: )9F:'G m NY-ot.. Specifies ciQ Address Phone/Fax - / - E-Mail: Sheet 4 of 4 Project: 1.JA(L01J6''G1 Glotr►'NG6V� C o n t r a c t No.: 41 O Zz o0 Respondble: Location/Date:- /11/7/2007 Anchoplate, steel: CUS1DM; f = 36000 psi Section type: Pipe section - HSS1- 11/16X.140 (1.69 x 1.69 x 0.14) Hole diameter ci = 0.44 in. Recommended plate thickness: not calculated Coordinates Anchor [in.] Anchor x 1.000 A O 1 1.000 3.500 3.500 10 m rn CO to M y Anchor x y 1 I -2.50 I -0.00 ' 2 I 2.50 I -0.00 I Anchorplate [in.] x y x x y Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor (c ) 2003 Hil9 AG, FL-9494 Schaan HMI is a registered Trademark of HIM AG, Schaan ADegenkolb Subject C tI j&ry c +� ti Job Number. Ai6- op Date: ff J Job: 5 I..)A(2 o 1/ 4.1 90 ui C e1 r i1 r� - t�4�Ja4 e�h 37ey' _ C•-j k 0 ,, (L c1/4i1uJ By: 64 Checked By: 1 b "Tc> c 4ZS + 5.1,xv5 +Y.cxZc° aZc e / : o. bas (13c.o,Cb) = 45 .fib /„d -resat - o.' ( 5 Yl•'Iz r1 C41_ Oti Erl-' A)W4 - 1 - t 11 ' 4 17 7 .1 12-11 J2 e - *,c.v11 6- - rep -1L. • o (,calyx ') : fz►s.b -1 O.q z zYTi0.0,4 t1' Section: Page lO of 0/ z(IPc J r" (cr) 1 1 00 7.o yZs . z -; 5.�5 y5v Z�3 'I,S 7 loo Z.5 Y zs 4 2' i s Ivy p,�r 0 Tyr z_ Ato c+ r Paz 0. 4199- tir5 VC 2' —Tr -7 1 ci ,c f �i okc icy _ /04 - Le& Z'c �.l�sE Z ii;P-1 0 t✓ir W yre cTrcAJ, -rvg- TV ZJr* CAW v'(ti)-Yy 1c„ Tz. ADegen Ica lb Subject: 94-I 6 - 1 _ , F- M ( i. i/ Job Number. AlOD`d UZ7. 00 Job: 5tjArt..j , tfL- Vi t ti N gryA cr-cf - c.la-trL CenhUcc - rcni Ay Tor' cF 5 -fiLLF To Vi1 c I ti' }-t 1,JSrn)c Ai Loacrnci\) o 54/-4.1-) To 9Turs By: CA Checked By: . 5,ox y -s ZSI> t zsx itc Date: tail 10-1 Section: J111 Page 1/ of t,= O,6Yis ri`�7Qb M' 5 - inikc Z �so,Q4� -{4 szzib aC 0.7 (A 7 5 G6t-eb 9Tt.t7 16" o. C_ 1`- io 7(4,b GA- CALL_ (- A!7 cf.) 9rur> '4 6, 6. 4/ 9 ", / C r4.0 J/vCLu y � UN 1C LS4 = 6. c> LP ,-1, G so J' - 7_ 15 14 h.-1,, . '',o C •��, u r Ad astable Super Erecte, Super Erects® gwikSLOT M (178mm) (6mm) SASES25BP -1 SASES50BP -1 It is recommended that a donut bumper be specified to cover any spaces between the post and the bolt plate anchor pipe. Specify the donut bumper to match the post type. SAQHD25BP -1 SAQHD50BP -1 MetroMax Q 09 /HD Super SAQHD25BP -2 SAQHD50BP -2 SASES25BP -4 SASES50BP -4 SES, SASE, QS = 9992DB SES HD = 9992H MetroMax Q = 9992DBX SAQHD25BP -4 SAQHD50BP -4 • • • • _ _ SASES25BP -1 SAS 25 = ' - = -. '.tio • . 4 Dimensions W x L One -post bolt plate, 1/4" wo -pas • • • ate, in. 2 x 7 x 1 / 4 / x 11 x 4 mm 73 x 178 x 6 3 x 27 • x • SASES25BP -4 Four -post bolt, plate, 1/4" 2 x 11 x 1 / 4 11 x 11 x 1 / 4 279 x 279 x 6 Four -post bolt plate, 1/4" 1 11 x 11 x 1 / 4 279 x 279 x 6 SASES50BP -1 ---... One -post bolt plate, 1/2" wo -post salt plate, 1 4 ••■••••- x 12 x 1 / 2 178 x 178 x 13 1 8 x I x 13 SASES50BP -4 Four -post bolt plate, 1/2" 1 12 x 12 x 1 /2 305 x 305 x 13 Part Number SAQHD25BP -1 Description One -post bolt plate, 1/4" 1 v. Dimensions W x Lx H in. 2 x 7 x 1 / 4 mm 73 x 178 x 6 SAQHD25BP -2 Two -post bolt plate, 1/4" 2 2 x 11 x 1 / 4 73 x 279 x 6 SAQHD25BP -4 Four -post bolt plate, 1/4" 1 11 x 11 x 1 / 4 279 x 279 x 6 SAQHD5OBP -1 One -post bolt plate, 1/2" 4 7 x 7 x 1 / 2 178 x 178 x 13 SAQHD5OBP -2 Two -post, 1/2" bolt plate 2 7 x 12 x 1 /2 178 x 305 x 13 SAQHD5OBP -4 Four -post, 1/2" bolt plate 1 12 x 12 x 305 x 305 x 13 A Example A requires one 1 -post starter kit, (ie. SASES25BP -1). SEISMIC SIIEIVINC SYSTEMS Super Erecta® (SES), Super Adjustable Super Erecta 2"" (SASE), gwikSlott` (QS), HD Super (HD), MetroMax Q® (Q) OSHPD Preapproved Bolt Plate Kits: For 1" diameter SES, SASE, and QS stationary post assemblies. Kit includes plate assem- blies and hardware to mount plates to posts. Floor anchors are not included. For 1.5" diameter HD and trilobal Q stationary post assemblies. Kit includes plates and hardware to mount plates to posts. Floor anchors are not included. 4 =j °1 B r Example B requires one 1 -post starter kit, (ie. SASES25BP -1) and one 2 -post adder kit, (ie. SASES25BP -2). Include one additional adder kit for each subsequent shelving unit added to the run. C Approved Fixed Equipment Anchorage California Office of Statewide Health Planning and Development OPA -0556 Required Components: To meet require- ments for preap- proval, simply add floor bolt - plates to standard Metro stationary shelving configurations and follow the installation and usage guidelines. Just add floor plates Example C requires one 1 -post starter kit, (ie. SASES25BP -1), two 2 -post adder kits (ie. SASES25BP -2), and one 4 -post adder kit, (ie. SASES25BP -4). Include one of each adder kit, (ie. one 2 -post kit and one 4 - post kit), for each additional pair of shelving units. EI'UHT' ICC Evaluation Service, Inc. Business/Regional ff I O' 5360 Workman Ma Road, W hittier , California 90601' (562) X ) 699-0543 W W W. Service, .O rq tonal Office • 900 Montclair Road, Suite A, Birmingham, Alabama 35213 • (205) 599 -9800 Regional Office • 4051 West Flossmaor Road, Country Club Hills, Illinois 60478 • (708)799 -2305 DIVISION: 03— CONCRETE Section: 03151 — Concrete Anchoring REPORT HOLDER: HILTI, INC. 5400 SOUTH 122 EAST AVENUE TULSA, OKLAHOMA 74146 (800) 879 -8000 www.us.hilti.com HiltiTechEno@us.hilti.com EVALUATION SUBJECT: HILTI KWIK BOLT TZ CARBON AND STAINLESS STEEL ANCHORS IN CONCRETE 1.0 EVALUATION SCOPE Compliance with the following codes: • 2006 International Building Code (IBC) • 2006 International Residential Code (IRC) • 1997 Uniform Building CodeTM (UBC) Property evaluated: Structural 2.0 USES The Hilti Kwik Bolt TZ anchor (KB -TZ) is used to resist static, wind, and seismic tension and shear loads in cracked and uncracked normal- weight concrete and structural sand lightweight concrete having a specified compressive strength, f . of 2,500 psi to 8,500 psi (17.2 MPa to 58.6 MPa); and cracked and uncracked normal- weight or structural sand lightweight concrete over metal deck having a minimum specified compressive strength, f', of 3,000 psi (20.7 MPa). The anchoring system is an alternative to cast -in -place anchors described in Sections 1911 and 1912 of the IBC and Sections 1923.1 and 1923.2 of the UBC. The anchors may also be used where an engineered design is submitted in accordance with Section R301.1.3 of the IRC. 3.0 DESCRIPTION KB -TZ anchors are torque - controlled, mechanical expansion anchors. KB -TZ anchors consist of a stud (anchor body), wedge (expansion elements), nut, and washer. The anchor (carbon steel version) is illustrated in Figure 1. The stud is manufactured from carbon or stainless steel materials with corrosion resistance equivalent to Type 304 stainless steel. Carbon steel KB -TZ anchors have a minimum 5 pm (0.00002 inch) zinc plating. The expansion elements for the carbon and stainless steel KB-TZ anchors are fabricated from stainless steel with corrosion resistance equivalent to Type 316 REPORTS are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 0 2007 Reissued September 1, 2007 This report is subject to re- examination in two years. stainless steel. The hex nut for carbon steel conforms to ASTM A 563 -04, Grade A, and the hex nut for stainless steel conforms to ASTM F 594. The anchor body is comprised of a high - strength rod threaded at one end and a tapered mandrel at the other end. The tapered mandrel is enclosed by a three - section expansion element which freely moves around the mandrel. The expansion element movement is restrained by the mandrel taper and by a collar. The anchor is installed in a predrilled hole with a hammer. When torque is applied to the nut of the installed anchor, the mandrel is drawn into the expansion element, which is in turn expanded against the wall of the drilled hole. Installation information and dimensions are set forth in Section 4.3 and Table 1. Normal- weight and structural lightweight concrete must conform to Sections 1903 and 1905 of the IBC and UBC. 4.0 DESIGN AND INSTALLATION 4.1 Strength Design: 4.1.1 General: Design strengths must be determined in accordance with ACI 318 -05 Appendix D and this report. Design parameters are provided in Tables 3 and 4. Strength reduction factors 0 as given in ACI 318 D.4.4 must be used for load combinations calculated in accordance with Section 1605.2.1 of the IBC or Section 1612.2 of the UBC. Strength reduction factors 0 as given in ACI 318 D.4.5 must be used for load combinations calculated in accordance with ACI 318 Appendix C or Section 1909.2 of the UBC. Strength reduction factors 0 corresponding to ductile steel elements may be used. An example calculation is provided in Figure 6. 4.1.2 Requirements for Static Steel Strength in Tension: The steel strength in tension must be calculated in accordance with ACI 318 D.5.1. The resulting N values are provided in Tables 3 and 4 of this report. 4.1.3 Requirements for Static Concrete Breakout Strength in Tension: The basic concrete breakout strength in tension must be calculated according to ACI 318 Section D.5.2.2, using the values of h and k„ as given in Tables 3 and 4 in lieu of h and k, respectively. The nominal concrete breakout strength in tension in regions where analysis indicates no cracking in accordance with ACI 318 Section D.5.2.6 must be calculated with 'P given in Tables 3 and 4. For carbon steel KB -TZ installed in the soffit of structural sand lightweight or normal- weight concrete on steel deck floor and roof assemblies, as shown in Figure 5, calculation of the concrete breakout strength may be omitted. (See Section 4.1.5.) 4.1.4 Requirements for Critical Edge Distance: In applications where c< c and supplemental reinforcement to control splitting of the concrete is not present, the concrete rs M..dierrwea.. r.mecsasiricani Page 1 of 14 CODE ACI 318 D.3.3. SEISMIC REGION CODE EQUIVALENT DESIGNATION IBC and IRC Moderate or high seismic risk Seismic Design Categories C, D, E, and F UBC Moderate or high seismic risk Seismic Zones 2B, 3, and 4 breakout strength in tension for uncracked concrete, calculated according to ACI 318 Section D.5.2, must be further multiplied by the factor W as given by the following equation: 4. C W CP N = ac whereby the factor WCP.N need not be taken as less than 1 he' . For all other cases, W CPN = 1.0. Values for the critical edge distance c must be taken from Table 3 or Table 4.1.5 Requirements for Static Pullout Strength in Tension: The pullout strength of the anchor in cracked and uncracked concrete, where applicable, is given in Tables 3 and 4. In accordance with ACI 318 Section D.5.3.2, the nominal pullout strength in cracked concrete must be calculated according to the following equation: C Nwi.►c = N p .cr 2,500 (I b, psi) N pn. t c = N 1.0 , —c (N, MPa) 17.2 In regions where analysis indicates no cracking in accordance with ACI 318 Section D.5.3.6, the nominal pullout strength in tension must be calculated according to the following equation: Npn,re = Np." 2,500 (Ib, psi) N„, N p.una ` ( N, MPa) 17.2 (1) (2) (3) Where values for N or N not provided in Table 3 or Table 4, the pullout strength in tension need not be evaluated. The pullout strength in cracked concrete of the carbon steel KB -TZ installed in the soffit of sand lightweight or normal - weight concrete on steel deck floor and roof assemblies, as shown in Figure 5, is given in Table 3. In accordance with ACI 318 Section D.5.3.2, the nominal pullout strength in cracked concrete must be calculated according to Eq. (2), whereby the value of N p , deC1c.0 , must be substituted for N The use of stainless steel KB -TZ anchors installed in the soffit of concrete on steel deck assemblies is beyond the scope of this report. In regions where analysis indicates no cracking in accordance with ACI 318 Section D.5.3.6, the nominal pullout strength in tension may be increased by WC.N as given in Table 3. W is 1.0 for all cases. Minimum anchor spacing along the flute for this condition must be the greater of 3.0h or 1 times the flute width. 4.1.6 Requirements for Static Steel Shear Capacity V,: In lieu of the value of V as given in ACI 318 Section D.6.1.2(c), the values of V given in Tables 3 and 4 of this report must be used. The shear strength Vs.dea as governed by steel failure of the KB -TZ installed in the soffit of structural sand lightweight or normal- weight concrete on steel deck floor and lc roof assemblies, as shown in Figure 5, is given in Table 3. 4.1.7 Requirements for Static Concrete Breakout Strength of Anchor in Shear, Vc, or Viceg: Static concrete breakout strength shear capacity must be calculated in accordance with ACI 318 Section D.6.2 based on the values provided in Tables 3 and 4. The value of l used in ACI 318 Equation (D -24) must taken as no greater than heF 4.1.8 Requirements for Static Concrete Pryout Strength of Anchor in Shear, V or V ,, • Static concrete pryout strength shear capacity must be calculated in accordance with ACI 318 Section D.6.3, modified by using the value of k,, provided in Tables 3 and 4 of this report and the value of N or N, as calculated in Section 4.1.3 of this report. For anchors installed in the soffit of structural sand lightweight or normal- weight concrete over profile steel deck floor and roof assemblies, as shown in Figure 5, calculation of the concrete pry-out strength in accordance with ACI 318 Section D.6.3 is not required. 4.1.9 Requirements for Minimum Member Thickness, Minimum Anchor Spacing and Minimum Edge Distance: In lieu of ACI 318 Section D.8.3, values of c and s as given in Tables 2 and 3 of this report must be used. In lieu of ACI 318 Section D.8.5, minimum member thicknesses h given in Tables 3 and 4 of this report must be used. Additional combinations for minimum edge distance c spacing s may be derived by linear interpolation between the given boundary values. (See Figure 4.) The critical edge distance at corners must be minimum 4h in accordance with ACI 318 Section D.8.6. 4.1.10 Requirements for Seismic Design: For load combinations including earthquake, the design must be performed according to ACI 318 Section D.3.3 as modified by Section 1908.1.16 of the IBC, as follows: The nominal steel strength and the nominal concrete breakout strength for anchors in tension, and the nominal concrete breakout strength and pryout strength for anchors in shear, must be calculated according to ACI 318 Sections D.5 and D.6, respectively, taking into account the corresponding values given in Tables 3 and 4. The anchors comply with ACI 318 D.1 as ductile steel elements and must be designed in accordance with ACI 318 Section D.3.3.4 or D.3.3.5. The nominal pullout strength Np,sers and the nominal steel strength for anchors in shear V must be evaluated with the values given in Tables 3 and 4. The values of Npses must be adjusted for concrete strength as follows: C N = Np. seis 2,500 (Ib, psi) Nps,,s.rc = Npses 17.2 (N, MPa) (4) If no values for N or Vs.sed are given in Table 3 or Table 4, the static design strength values govern. (See Sections 4.1.5 and 4.1.6.) 4.1.11 Structural Sand Lightweight Concrete: When structural lightweight concrete is used, values determined in REFERENCE FOR STRENGTH REDUCTION FACTORS a Including Seismic Excluding Seismic ACI 318 Section D.4.4 1.1 1.4 ACI 318 Section D.4.5 1.2 1.55 t ti accordance with ACI 318 Appendix D and this report must be modified by a factor of 0.60. 4.1.12 Structural Sand Lightweight Concrete over Metal Deck: Use of structural sand lightweight concrete is allowed in accordance with values presented in Table 3 and installation details as show in Figure 5. 4.2 Allowable Stress Design: 4.2.1 General: Design resistances for use with allowable stress design load combinations calculated in accordance with Section 1605.3 of the IBC and Section 1612.3 of the UBC, must be established as follows: R = _q (5) kkow.as - a where Rd = • Rk represents the limiting design strength in tension (bN„) or shear (OV „) as calculated according to ACI 318 Sections D.4.1.1 and D.4.1.2 and Section 4.1 of this report. For load combinations including earthquake, the value Rd in Equation (5) must be multiplied by 0.75 in accordance with ACI 318 Section D.3.3.3. Limits on edge distance, anchor spacing and member thickness, as given in Tables 3 and 4 of this report, must apply. Allowable service loads for single anchors in tension and shear with no edge distance or spacing reduction are provided in Tables 6 through 9, for illustration. These values have been derived per Equation (5) using the appropriate strength reduction factors Ofrom Tables 3 and 4 and the a factors provided in Section 4.2 of this report. The value of a must be taken as follows: 4.2.2 Interaction: In lieu of ACI 318 D.7.1, D.7.2 and D.7.3, interaction must be calculated as follows: For shear loads V s 0.2 • Vdn„w.ASa the full allowable load in tension Talaw.ASD may be taken. For tension loads T s 0.2 • T,,, the full allowable load in shear V may be taken. For all other cases: T V + s 1.2 (6) T adow,ASD V allow.ASD 4.3 Installation: Installation parameters are provided in Table 1 and in Figure 2. The Hilti KB -TZ must be installed according to manufacturer's published instructions and this report. Anchors must be installed in holes drilled into the concrete using carbide- tipped masonry drill bits complying with ANSI B212.15 -1994. The nominal drill bit diameter must be equal to that of the anchor. The drilled hole must exceed the depth of anchor embedment by at least one anchor diameter to permit over - driving of anchors and to provide a dust collection area as required. The anchor must be hammered into the predrilled hole until at least four threads are below the fixture surface. The nut must be tightened against the washer until the torque values specified in Table 1 are achieved. For installation in the soffit of concrete on steel deck assemblies, the hole diameter in the steel deck not exceed the diameter of the hole in the concrete by more than '4 inch (3.2 mm). For member thickness and edge distance restrictions for installations into the soffit of concrete on steel deck / assemblies, see Figure 5. 4.4 Special Inspection: Special inspection is required, in accordance with Section 1704.13 of the IBC and Section 1701.5.2 of the UBC. The special inspector must be on the jobsite continuously during anchor installation to verify anchor type, anchor dimensions, concrete type, concrete compressive strength, hole dimensions, hole cleaning procedures, anchor spacing, edge distances, concrete thickness, anchor embedment, and tightening torque. 5.0 CONDITIONS OF USE The Hilti KB -TZ anchors described in this report comply with the codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Anchor sizes, dimensions and minimum embedment depths are as set forth in this report. 5.2 The anchors must be installed in accordance with the manufacturer's published instructions and this report. In case of conflict, this report governs. 5.3 Anchors must be limited to use in cracked and uncracked normal- weight concrete and structural sand lightweight concrete having a specified compressive strength, f , of 2,500 psi to 8,500 psi (17.2 MPa to 58.6 MPa), and cracked and uncracked normal- weight or structural sand lightweight concrete over metal deck having a minimum specified compressive strength, f of 3,000 psi (20.7 MPa). 5.4 The values of f , used for calculation purposes must not exceed 8,000 psi (55.1 MPa). 5.5 Loads applied to the anchors must be adjusted in accordance with Section 1605.2 of the IBC and Sections1612.2 or 1909.2 of the UBC for strength design, and in accordance with Section 1605.3 of the IBC and Section 1612.3 of the UBC for allowable stress design. 5.6 Strength design values must be established in accordance with Section 4.1 of this report. 53 Allowable design values are established in accordance with Section 4.2. 5.8 Anchor spacing and edge distance as well as minimum member thickness must comply with Tables 3 and 4. 5.9 Prior to installation, calculations and details demonstrating compliance with this report must be submitted to the code official. The calculations and details must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. 5.10 Since an ICC -ES acceptance criteria for evaluating data to determine the performance of expansion anchors subjected to fatigue or shock loading is unavailable at this time, the use of these anchors under such conditions is beyond the scope of this report. 5.11 Anchors may be installed in regions of concrete where cracking has occurred or where analysis indicates cracking may occur (f 1), subject to the conditions of this report. 5.12 Anchors may be used to resist short-term loading due to wind or seismic forces, subject to the conditions of this report. 5.13 Where not otherwise prohibited in the code, KB -TZ anchors are permitted for use with fire - resistance -rated construction provided that at least one of the following conditions is fulfilled: • Anchors are used to resist wind or seismic forces only. • Anchors that support a fire - resistance -rated envelope or a fire- resistance -rated membrane are protected by approved fire- resistance- rated materials, or have been evaluated for resistance to fire exposure in accordance with recognized standards. • Anchors are used to support nonstructural elements. 5.14 Use of zinc - coated carbon steel anchors is limited to dry, interior locations. 5.15 Special inspection must be provided in accordance with Section 4.4. 5.16 Anchors are manufactured by Hilti AG, in Schaan, Liechtenstein, under a quality control program with inspections by Underwriters Laboratories Inc. (AA -637). 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC -ES Acceptance Criteria for Mechanical Anchors in Concrete Elements (AC193), dated January 2007 (ACI 355.2). 6.2 A quality control manual. 7.0 IDENTIFICATION The anchors are identified by packaging labeled with the manufacturer's name (Hilti, Inc.) and contact information, anchor name, anchor size, evaluation report number (ICC -ES ESR- 1917), and the name of the inspection agency (Underwriters Laboratories Inc.). The anchors have the letters KB-TZ embossed on the anchor stud and four notches embossed into the anchor head, and these are visible after installation for verification. TABLE 1 —SETTING INFORMATION (CARBON STEEL AND STAINLESS STEEL ANCHORS) SETTING INFORMATION Symbol Units Nominal anchor diameter (in.) 3/8 1/2 5/8 314 Anchor O.D. do In. (mm) 0.375 (9.5) 0.5 (12.7) 0.625 (15.9) 0.75 (19.1) Nominal bit diameter day In. 3/8 1/2 5/8 3/4 Effective min. embedment het In. (mm) 2 (51) 2 (51) 3 -1/4 (83) 3 -1/8 (79) 4 (102) 3 -3/4 (95) 4 -3/4 (121) Min. hole depth h. In. (mm) 2 -5/8 (67) 2 -5/8 (67) 4 (102) 3 -7/8 (98) 4 -3/4 (121) 4.5/8 (117) 5 -3/4 (146) Min. thickness of fastened party 6, In. (mm) 1/4 (6) 3/4 (19) 1/4 (6) 3/8 (9) 3/4 (19) 1/8 (3) 1 -5/8 (41) Installation torque Thu ft -lb (NO 25 (34) 40 (54) 60 (81) 110 (149) Min. dia. of hole in fastened part do In. (mm) 7/16 (11.1) 9/16 (14.3) 11/16 (17.5) 13/16 (20.6) Standard anchor lengths In. (mm) 3 3 -3/4 5 3 -3/4 4 -1/2 5 -1/2 7 4 -3/4 6 8 -1/2 10 5 -1/2 8 10 (76) (95) (127) (95) (114) (140) (178) (121) (152) (216) (254) (140) (203) (254) Threaded length find. dog point) ___ In. (mm) 7/8 1 -5/8 2 -7/8 1 -5/8 2 -3/8 3 -3/8 4 -7/8 1 -1/2 2 -3/4 5 -1/4 6 -3/4 1 -1/2 4 6 (22) (41) (73) (41) (60) (86) (124) (38) (70) (133) (171) (38) (102) (152) Unthreaded length,, In. (mm) 2 -1/8 (54) 2 -1/8 (54) 3-1/4 (83) 4 (102) mandrel expansion element collar bolt setting assist UNC thread washer FIGURE 1 — HILTI CARBON STEEL KWIK BOLT TZ (KB - TZ) hex nut dog point The minimum thickness of the fastened part is based on use of the anchor at minimum embedment and is controlled by the length of thread. If a thinner fastening thickness is required, increase the anchor embedment to suit. Length ID marking on bolt head A B C D E F G H I J K L M N O P Q R S T U V W Length of anchor, tench (inches) From 1 ½ 2 2 5 4 3 3 5 4 4 4 ½ 5 514 6 614 7 714 8 814 9 914 10 11 12 13 14 15 Up to but nOt including 2 2 14 3 3 14 4 4 li 5 514 6 61/2 7 7 %4 8 814 9 914 10 11 12 13 14 15 16 tanch `thread tunthr • t FIGURE 2 —KB -TZ INSTALLED hef t. h' A h TABLE 2— LENGTH IDENTIFICATION SYSTEM (CARBON STEEL AND STAINLESS STEEL ANCHORS) FIGURE 3 —BOLT HEAD WITH LENGTH IDENTIFICATION CODE AND KB -TZ HEAD NOTCH EMBOSSMENT DESIGN INFORMATION Symbol Units Nominal anchor diameter 3/8 1/2 5/8 3/4 Anchor O.D. d° In. (mm) 0.375 (9.5) 0 5 (12.7) 0.625 (15.9) 0.75 (19.1 Effective min. embedment h,, In. (mm) 2 (51) 2 (51) 3-1/4 (83) 3-1/8 (79) 4 (102) 3-3/4 (95) 4 -3/4 (121) 8 (203) Min. member thickness h.*, In. (mm) 4 (102) 5 (127) 4 (102) 6 (152) 6 (152) 8 (203) 5 (127) 6 (152) 8 (203) 6 (152) 8 (203) Critical edge distance c,c In. (mm) 4 -3/8 (111) 4 (102) 5-1/2 (140) 4 -1/2 (114) 7 -1/2 (191) 6 (152) 6-1/2 (165) 8 -3/4 (222) 6-3/4 (171) 10 (254) 8 (203) 9 (229) Min. edge distance c,,,N, In. (mm) 2- /2 (64) 2 -3/4 (70) 2-3/8 (60) 3 -5/8 (92) 3-1/4 (83) 4-3/4 (121) 4 -1/8 (105) 8 -7/8 (225) for s 2 In. (mm) 5 (127) 5-3/4 (146) 5 -3/4 (146) 6-1/8 (156) 5 -7/8 (149) 10-1/2 (267) Min. anchor spacing s,,,,,, In. (mm) 2 -1/2 (64) 2 -3/4 (70) 2 -3/8 (60) 3-1/2 (89) 3 (76) 5 (127) 4 (102) 7-3/4 (197) 5 -3/4 (146) for c 2 In. (mm) 3-5/8 (92) 4-1/8 (105) 3-1/2 (89) 4 -3/4 (121) 4 -1/4 (108) 9 -1/2 (241) Min. hole depth in concrete ho In. (mm ) 2 -5/8 (67) 2 -5/8 (67) 4 (102) 3-7/8 (98) 4 -3/4 (121) 4 -5/8 (117) Min. specified yield strength /r lb/in (N/mm 100,000 (690) 84,800 (585) 84,800 (585) 84,800 (585) Min. specified ult. strength /, Ib/in (N/mm 125,000 (862) 106,000 (731) 106,000 (731) 106,000 (731) Effective tensile stress area A. In (mm) 0.052 (33.6) 0.101 (65.0) 0.162 (104.6) 0.237 (152.8) Steel strength In tension N° lb (kN) 6,500 (28.9) 10,705 (47.6) 17,170 (76.4) 25,120 (111.8) Steel strength in shear V, lb (kN) 3,595 (16.0) 6,405 (28.5) 10,555 (47.0) 15,930 (70.9) Steel strength in shear, seismic V ' ° ' B lb (kN) 2,255 (10.0) 6,405 (28.5) 10,555 (47.0) 14,245 (63.4) Steel strength in shear, concrete on metal deck` V °.deck lb (kN) 2130 (9.5) 3,000 (13.3) 4,945 (22) 4,600 (20.5) 6,040 (26.9) NP NP Pullout strength uncracked concrete N v'""` lb (kN) 2,515 (11.2) NA 5,515 (24.5) NA 9,145 (40.7) 8,280 (36.8) 10,680 (47.5) Pullout strength cracked concrete NAG{ lb (kN) 2,270 (10.1) NA 4,915 (21.9) NA NA NA NA Pullout strength concrete on metal deck N0 lb (kN) 1,460 (6.5) 1,460 (6.5) 2,620 (11.7) 2,000 (8.9) 4,645 (20.7) NP NP Anchor category' 1 Effectiveness factor k uncracked concrete 24 Effectiveness factor /k, cracked concrete 17 ‘Pc,e= kuncika 1.41 Coefficient for pryout strength, k 1.0 I 2.0 Strength reduction factor 0 for tension, steel failure modes 0.75 Strength reduction factor 0 for shear, steel failure modes 0.65 Strength reduction 0 factor for tension, concrete failure modes or pullout, Condition B" 0.65 Strength reduction 0 factor for shear, concrete failure modes, Condition B" 0.70 TABLE 3- DESIGN INFORMATION F or St: 1 inch = 25.4 mm, 1 Ibf = 4.45 N, 1 psi = 0.006895 MPa For pound -inch units: 1 mm = 0.03937 inches. 'See Fig. 2. 2 For structural light- weight concrete over metal deck, see Figure 5. 3 See Section 4.1.10 of this report. 'See Section 4.1.6. NP (not permitted) denotes that the condition is not supported by this report. % See Section 4.1.5 of this report. NA (not applicable) denotes that this value does not control for design. ° See Section 4.1.5 of this report. NP (not permitted) denotes that the condition is not supported by this report. Values are for cracked concrete. Values are applicable to both static and seismic load combinations. 'See ACI 318 Section D.4.4. ° See ACI 318 -05 Section D.5.2.2. ° See ACI 318 -05 Section 0.52.6. 10 The KB-TZ is a ductile steel element as defined by ACI 318 Section D.1. 11 For use with the load combinations of ACI 318 Section 9.2. Condition B applies where supplementary reinforcement in conformance with ACI 318 -05 Section D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. z DESIGN INFORMATION Symbol Units Nominal anchor diameter 3/8 1/2 5/8 3/4 Anchor O.D. do in. (mm) 0.375 (9.5) 0.5 (12.7) 0.625 (15.9) 0.75 (19.1 Effective min. embedment' ha in. (mm) 2 (51) 2 (51) 3-1/4 (83) 3-1/8 (79) 4 (102) 3-3/4 95) 43/4 (121) Min. member thickness h,,„„ in. (mm) 4 (102) 5 (127) 4 (102) 6 (152) 6 (152) 8 (203) 5 (127) 6 (152) 8 (203) 6 (152) 8 (203) 8 (203) Critical edge distance c� in. (mm) 4-3/8 (111) 3-7/8 (98) 5-1/2 (140) 4-1/2 (114) 7 -1/2 (191) 6 (152) 7 (178) 8-7/8 (225) 6 (152) 10 (254) 7 (178) 9 (229) Min. edge distance A in. (mm) 2- /2 (84) 2 -7/8 (73) 2 -1/8 (54) 3-1/4 (83) 2 3/8 (60) 4 -1/4 (108) 4 (102) for 2 in. (mm) 5 (127) 5 -3/4 (146) 5 -1/4 (133) 5-1/2 (140) 5 -1/2 (140) 10 (254) 8 -1/2 (216) Min. anchor spacing s in. (mm) 2 -1/4 (57) 2 -7/8 (73) 2 (51) 2 -3/4 (70) 2 -3/8 (60) 5 (127) 4 (102) 7 (178) 5 -3/4 (146) for ca in. (mm) 3-1/2 (89) 4 -1/2 (114) 3-1/4 (83) 4 -1/8 (105) 4 -1/4 (108) 9 -1/2 (241) Min. hole depth in concrete ho in. (mm) 2 -5/8 (67) 2 -5/8 (67) 4 (102) 3-7/8 (98) 4-3/4 (121) 4 -5/8 (117) Min. specified yield strength f Y lb/in (N/mm 92,000 (634) 92,000 (634) 92,000 (634) 76,125 (525) Min. specified ult. Strength f„ IbM` (N /mm ) 115,000 (793) 115,000 (793) 115,000 (793) 101,500 (700) Effective tensile stress area As„ in (mm) 0.052 (33.6) 0.101 (65.0) 0.162 (104.6) 0.237 (152.8) Steel strength in tension N8 lb (kN) 5,968 (26.6) 11,554 (51.7) 17,880 (82.9) 24,055 (107.0) Steel strength in shear V, lb (kN) 4,870 (21.7) 6,880 (30.6) 11,835 (52.6) 20,050 (89.2) Pullout strength in tension, seismic2 N lb (kN) NA 2,735 (12.2) NA NA NA Steel strength In shear, seismic2 V. b lb (kN) 2,825 (12.6) 6,880 (30.6) 11,835 (52.6) 14,615 (65.0) Pullout strength uncracked concrete N ° lb (kN) 2,630 (11.7) NA 5,760 (25.6) NA NA 12,040 (53.6) Pullout strength cracked concrete N ° lb (kN) 2,340 (10.4) 3,180 (14.1) NA NA 5,840 (26.0) 8,110 (36.1) NA Anchor category` 1 Effectiveness factor k,,,,„ uncracked concrete 24 Effectiveness factor k„, cracked concrete 17 24 17 17 17 24 17 wc.N = kuncikr 1.41 1.00 1.41 1.41 1.41 1.00 1.41 Strength reduction factor 0 for tension, steel failure modes' 0.75 Strength reduction factor 0 for shear, steel failure modes' 0.65 Strength reduction 0 factor for tension, concrete failure modes, Condition B 0.65 Coefficient for pryout strength, k 1.0 2.0 Strength reduction 0 factor for shear, concrete failure modes, Condition B 0.70 TABLE 4-DESI For S I : 1 mch = 25.4 mm, 1 Ibf = 4.45 N, 1 psi = 0.006895 MPa For pound -inch units: 1 mm = 0.03937 inches 'See Fig. 2. 2 See Section 4.1.10 of this report. NA (not applicable) denotes that this value does not control for design. 'See Section 4.1.5 of this report. NA (not applicable) denotes that this value does not control for design. `See ACI 318 -05 Section 0.4.4. 5 See ACI 318 -05 Section D.5.2.2. See ACI 318-05 Section D.5.2.6. 'The KB -TZ is a ductile steel element as defined by ACI 318 Section D.1. ° For use with the load combinations of ACI 318 -05 Section 9.2. Condition B applies where supplementary reinforcement in conformance with ACI 318 -05 Section D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. Z7 Nominal Anchor Diameter Embedment Depth he, (in.) Concrete Compressive Strength f c = 2,500 psi fc = 3,000 psi fc = 4,000 psi fc = 6,000 psi Carbon steel Stainless steel Carbon steel Stainless steel Carbon steel Stainless steel Carbon steel Stainless steel 3/8 2 1,168 1,221 1,279 1,338 1,477 1,545 1,809 1,892 1/2 2 1,576 1,576 1,726 1,726 1,993 1,993 2,441 2,441 31/4 2,561 2,674 2,805 2,930 3,239 3,383 3,967 4,143 5/8 31/8 3,078 3,078 3,372 3,372 3,893 3,893 4,768 4,768 4 4,246 4,457 4,651 4,883 5,371 5,638 6,578 6,905 3/4 3 3/4 3,844 4,046 4,211 4,432 4,863 5,118 5,956 6,268 4 3/4 4,959 5,590 5,432 6,124 6,272 7,071 7,682 8,660 Concrete condition carbon steel KB -TZ, all diameters stainless steel KB -TZ, all diameters uncracked concrete 700 120 cracked concrete 500 90 f� Sdesign Cd J9 • 1111 ills 1 ht h„ , „ S design or SI: 1 Ibf = 4. N, 1 psi = 0.00689 MPa For pound -inch units: 1 mm = 0.03937 inches Cmin at s 2 hmin • C design FIGURE 4- INTERPOLATION OF MINIMUM EDGE DISTANCE AND ANCHOR SPACING edge distance c TABLE 5-MEAN AXIAL STIFFNESS VALUES 11 FOR KB-TZ CARBON AND STAINLESS STEEL ANCHORS IN NORMAL-WEIGHT CONCRETE (10 'Mean values shown, actual stiffness may vary considerably depending on concre e strength, loading and geometry of application. TABLE 6 -KB -TZ CARBON AND STAINLESS STEEL ALLOWABLE STATIC TENSION (ASD), NORMAL - WEIGHT UNCRACKED CONCRETE, CONDITION B (pounds) 'Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of Rd as per ACI 318 -05 and conversion to ASD in accordance with Section 4.2.1 Eq. (5) of this report is required. 2 Values are for normal weight concrete. For sand - lightweight concrete, multiply values by 0.60. 'Condition B applies where supplementary reinforcement in conformance with ACI 318 -05 Section D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. it/ Nominal Anchor Diameter Embedment Depth h (in.) Concrete Compressive Strength fc = 2,500 psi fc = 3,000 psi fc = 4,000 psi fc = 6,000 psi Carbon steel Stainless steel Carbon steel Stainless steel Carbon steel Stainless steel Carbon steel Stainless steel 3/8 2 1,054 1,086 1,155 1,190 1,333 1,374 1,633 1,683 1/2 2 1,116 1,476 1,223 1,617 1,412 1,868 1,729 2,287 31/4 2,282 2,312 2,500 2,533 2,886 2,925 3,535 3,582 5/8 31/8 2,180 2,180 2,388 2,388 2,758 2,758 3,377 3,377 4 3,157 2,711 3,458 2,970 3,994 3,430 4,891 4,201 3/4 3 3/4 2,866 3,765 3,139 4,125 3,625 4,763 4,440 5,833 43/4 4,085 4,085 4,475 4,475 5,168 5,168 6,329 6,329 Nominal Anchor Diameter Allowable Steel Capacity, Static Shear Carbon Steel Stainless Steel 3/8 1,669 2,661 1/2 2,974 3,194 5/8 4,901 5,495 3/4 7,396 9,309 TABLE 7 -KB -TZ CARBON AND STAINLESS STEEL ALLOWABLE STATIC TENSION (ASD), NORMAL - WEIGHT 1 CRACKED CONCRETE, CONDITION B (pounds)1'2' 3 or SI: 1 Ibf = 4.45 N, 1 psi = 0.00689 MPa For pound -inch units: 1 mm = 0.03937 inches 'Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of Rd as per ACI 318 -05 and conversion to ASD in accordance with Section 4.2.1 Eq. (5) is required. 2 Values are for normal weight concrete. For sand - lightweight concrete, multiply values by 0.60. 3 Condition B applies where supplementary reinforcement In conformance with ACI 318 -05 Section D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. TABLE 8 -KB -TZ CARBON AND STAINLESS STEEL ALLOWABLE STATIC SHEAR LOAD (ASD), (pounds)' For SI: 1 Ibf = 4.45 N 'Values are for single anchors with no edge distance or spacing reduction due to concrete failure. a�� Nominal Anchor Diameter Embedment Depth he (in.) Concrete Compressive Strength f c = 2,500 psi f'c = 3,000 psi f c = 4,000 psi f'c = 6,000 psi Carbon steel Stainless steel Carbon steel Stainless steel Carbon steel Stainless steel Carbon steel Stainless steel 3/8 2 1,006 1,037 1,102 1,136 1,273 1,312 1,559 1,607 1/2 2 1,065 1,212 1,167 1,328 1,348 1,533 1,651 1,878 31/4 2,178 2,207 2,386 2,418 2,755 2,792 3,375 3,419 5/8 31/8 2,081 2,081 2,280 2,280 2,632 2,632 3,224 3,224 4 3,014 2,588 3,301 2,835 3,812 3,274 4,669 4,010 3/4 3 3/4 2,736 3,594 2,997 3,937 3,460 4,546 4,238 5,568 4 3/4 3,900 3,900 4,272 4,272 4,933 4,933 6,042 6,042 Nominal Anchor Diameter Allowable Steel Capacity, Seismic Shear Carbon Steel Stainless Steel 3/8 999 1,252 1/2 2,839 3,049 5/8 4,678 5,245 3/4 6,313 6,477 TABLE 9 -KB -TZ CARBON AND STAINLESS STEEL ALLOWABLE SEISMIC TENSION (ASD), NORMAL - WEIGHT CRACKED CONCRETE, CONDITION B (pounds) Te For Si: 1 Ibf = 4.45 N, 1 psi = 0.00689 MPa For pound -inch units: 1 mm = 0.03937 inches 'Values are for single anchors with no edge distance or spacing reduction. For other cases, calculation of Rd as per ACI 318 -05 and conversion to ASD in accordance with Section 4.2.1 Eq. (5) is required. 2 Values are for normal weight concrete. For sand - lightweight concrete, multiply values by 0.60. 3 Condition B applies where supplementary reinforcement in conformance with ACI 318 -05 Section D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. TABLE 10 -KB -TZ CARBON AND STAINLESS STEEL ALLOWABLE SEISMIC SHEAR LOAD (ASD), (pounds)' For SI: 1 Ibf = 4.45 N 'Values are for single anchors with no edge distance or spacing reduction due to concrete failure. NOMINAL ANCHOR DIAMETER EMBEDMENT DEPTH, he (inches) TENSION SEISMIC TENSION NONSEISMIC SHEAR SEISMIC SHEAR NONSEISMIC 3/8 2 709 743 944 989 1/2 2 709 743 1,330 1,393 1/2 3-1/4 1,272 1,333 2,192 2,296 5/8 3-1/8 971 1,017 2,039 2,136 5/8 4 2,255 2,362 2,677 2,804 ti TABLE 11 —KB -TZ CARBON STEEL ALLOWABLE TENSION AND SHEAR LOADS (ASD), INSTALLED INTO THE UNDERSIDE OF A STRUCTURAL SAND LIGHTWEIGHT CONCRETE OVER METAL DECK SLAB (pounds) For SI: 1 plf = 4.45 N, 1 inch =25.4 mm. 'Pullout strength values Np,d are for anchors installed in structural sand lightweight concrete having a minimum 2,500 psi compressive strength at the time of installation. See Table 3. The values listed in Table 11 have been calculated assuming a minimum 3,000 psi concrete compressive strength. The pullout strengths may be adjusted for other lightweight concrete compressive strengths in accordance with Section 4.1.5 using the following reduction equation: Np.deck.fc = Np.deck Np.deck.fc = Np.deck Y (Ib, psi)* 2,500 I1 r (N, MPa)* 7.2 This equation can be used for structural sand lightweight concrete compressive strengths between 2,500 psi and 4,000 psi (17 MPa and 28 MPa). 2 Minimum anchor spacing along the flute shall be the greater of 3.0 he or 1.5 times the flute width in accordance with Section 4.1.4. 3 Anchors in the lower flute may be installed with a maximum 1 -inch offset in either direction. See Figure 5. 4 Allowable seismic tension and shear loads are calculated by multiplying Np,d and V by the strength reduction 0 factor of 0.65, the seismic reduction 0 factor of 0.75 according to ACI 318 D3.3.3, and the dividing by an a of 1.1 in accordance with Section 4.2.1. 5 Allowable nonseismic tension and shear loads are calculated by multiplying Np,d and V by the strength reduction 0 factor of 0.65 and dividing by an a of 1.4 in accordance with Section 4.2.1. Allowable nonseismic loads are calculated assuming the lightweight concrete over metal deck is cracked. ZS/ c J CO ZU i a z in MIN. 3,000 PSI NORMAL OR SAND - LIGHTWEIGHT CONCRETE UPPER FLUTE (VALLEY) • MIN. 20 GAUGE STEEL W -DECK LOWER FLUTE (RIDGE) FIGURE 5— INSTALLATION IN THE SOFFIT OF CONCRETE OVER METAL DECK FLOOR AND ROOF ASSEMBLIES Given: Two 1 12-inch KB -TZ anchors under A r- t Tan A static tension load as shown. s ) N = '' 1.5 he h = 3.25 in. Normal wt. concrete, f = 3,000 psi No supplementary reinforcing. A ssume uncracked concrete. Condition B per ACI 318 D.4.4 c) Calculate the allowable tension load for this configuration. LLLL-.1--1) I � r `' " �. , .; s =6" ° 1.5h e f i v v•. :.:..., A -A Calculation per ACI 318 -02 Appendix D and this report. Code Ref. Report Ref. Step 1. Calculate steel capacity. 0 N, = 0 nA ., = 0.75 x 2 x 0.101 x 106,000 = 16,059 lb Check whether f, is not greater than 1.9f and 125,000 psi. D.5.1.2 D.4.4 a a) Table 3 Step 3. Calculate concrete breakout strength of anchor in tension: _ Ncbg D.5.2 § 4.1.2 § 4.1.3 NCO Ivec,NY'ed,Nrc,NY'cp,NNb Step 3a. Verify minimum member thickness, spacing and edge distance: smin h = 6 in. 5 6 in. :. ok 2.375 - 5.75 2.375, 5.75 3.5, 2.375 D.8 Table 3 Fig. 4 slope = - 3.0 3.5 - 2.375 For c m;R = 4in 2.375 controls S min = 5.75 - [(2.375 - 4.0)( -3.0)] = 0.875 < 2.375in < 6in :. ok 0.875 ■ 4 Cmn Step 3b. For AN check 1.5h, = 1.5(3.25) = 4.88 in > c 3.0h,, = 3(3.25) = 9.75 in > s D.5.2.1 Table 3 Step 3c. Calculate Ant and AN for the anchorage: A = 9hN = 9 x (3.25) = 95.1 in 4 = (1.5h„ +c )( 3h,, +s ( = 1.5 3.25 ) +4 ( 3x 3.25 ) +6 = 139.8 in <2•A D.5.2.1 Table 3 Step 3d. Determine yr, : e = 0 . . 1v ec,N =1 D.5.2.4 - Step 3e. Calculate Nb: N = k f- h 5 =17 x Ifi,100 x 3.25' = 5,456 lb D.5.2.2 Table 3 Step 3f. Calculate modification factor for edge distance: =03 + 0.3 - 0.95 D.5.2.5 Table 3 y 1.5(3 25) Step 3g. wc.N =1.41 (uncracked concrete) D.5.2.6 Table 3 Step 3h. Calculate modification factor for splitting: K. = max I.5h 0.65>0.53.. - 1.5(3.25) c ' 1.5h,f 4 § 4.1.3 Table 3 c °C check: 7 55 =0.53; 7 5 - 0.65 controls c °c Step 3i. Calculate mN : 'DN 0.65 x 139.8 x 1.00 x 0.95 x 1.41 x 5,456 x 0.65 = 4,539 lb D.5.2.1 D.4.4 c) § 4.1.2 Table 3 95.1 D.5.3.2 D.4.4 c) § 4.1.5 Table 3 Step 4. Check pullout strength: Per Table 3, onN,,,,,r = 0.65x2x5,515 lb 3,000 = 7,852 lb >4539 .. OK 2,500 Step 5. Controlling strength: 'DN = 4,539 lb < onNp„ < 0N .. ONE controls D.4.1.2 Table 3 Step 6. Convert value to ASD: Tallow= 4.539 - 3,242 lb. - § 4.2 l a d FIGURE 6- EXAMPLE CALCULATION DEPARTMENTS: (, Division � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -429 DATE: 11 -21 -07 PROJECT NAME: SWAROVSKI, STORAGE RACKS SITE ADDRESS: 636 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Public Works n Structural 0 Fire Prevention is,k DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 Incomplete - C APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division Permit Coordinator No further Review Required DATE: DATE: DUE DATE: 11-27-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 12-25-07 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License WESTWCI088BF Licensee Name WESTWOOD CONTRACTORS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601011419 Ind. Ins. Account Id - Business Type CORPORATION Address 1 951 W 7TH STREET Address 2 ATTENTION: LILY SEGURA City FORT WORTH County OUT OF STATE State TX Zip 76102 Phone 8178773800 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/6/1992 Expiration Date 9/11/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BENDA, ROBERT D 01/01/1980 06/11 /2002 CHASE, DAVID E 01/01/1980 06/11 /2002 BENDA, JOAN M 01/01/1980 06/11/2002 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS CAS & Until httros: // fortress .wa.gov /lni/bbin/nrintenasnx ?License= WESTWCI088BF 02/04/200