Loading...
HomeMy WebLinkAboutPermit D07-439 - PAYLESS SHOES - TENANT IMPROVEMENTPAYLESS SHOES 17250 SOUTHCENTER PY SUITE 128 D07 -439 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D07 -439 Occupant /Tenant: PAYLESS SHOES Building Address: 17250 SOUTHCENTER PY, SUITE NO. 128 Parcel No.: 2623049117 Property Owner: WIG PROPERTIES LLC-SS 4811 134TH PL SE , BELLEVUE WA 98006 Use: RETAIL SALES Occupancy Group/Division: M Type of Construction: V -B Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: 79 dale, 206 OFFTC BUILDIN DATE THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: 2623049117 Address: 17250 SOUTHCENTER PY TUKW Suite No: City if Tukwila Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Phone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: PAYLESS SHOES Address: 17250 SOUTHCENTER PY SUITE 128 , TUKWILA WA Contractor: Name: CONSTRUCTION EXPDTNG SRVCS INC Address: 13620 LINCOLN WY 3210 , AUBURN CA 95360 Phone: Contractor License No: CONSTES944B3 DEVELOPMENT PERMIT Contact Person: Name: CORNEL PURAVET Address: 10230 NE POINTS DR SUITE 300 , KIRKLAND WA 98033 Phone: 425 -827 -2100 * *continued on next page ** Permit Number: D07 - 439 Issue Date: 04/08/2008 Permit Expires On: 10/05/2008 Expiration Date: 01/23/2010 DESCRIPTION OF WORK: INSTALL INTERIOR WALL AND FLOOR FINISHES. INSTALL DISPLAY FIXTURES, CHECK -OUT COUNTER, OFFICE FURNITURE, AND SHELVING. PROVIDE ELECTRICAL CONNECTIONS FOR CASH REGISTERS Value of Construction: $100,000.00 Fees Collected: $2,037.27 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0019 doc: IBC-10 /06 D07 -439 Printed: 04 -08 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: The granting of this permit does not pres construction or pe ormance of w Signature: Print Name: City oar/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D07 -439 Issue Date: 04/08/2008 Permit Expires On: 10/05/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Date: 011 011 �/ b I hereby certify that I have read and *ax4uted this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied t , whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating uthorized to sign and obtain this development permit. Date: c This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D07 -439 Printed: 04 -08 -2008 Parcel No.: 2623049117 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17250 SOUTHCENTER PY TUICW PAYLESS SHOES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 5: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -439 ISSUED 11/29/2007 04/08/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 7: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4 -4) 12: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. doc: Cond -10/06 D07 -439 Printed: 04 -08 -2008 (IFC 1008.1.8.3 subsection 2.2) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13: Install a sign in one inch high letters over the door stating: "This Door to Remain Unlocked During Business Hours ". (IFC 1008.1.8.3 subsection 2.2) 14: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 15: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 16: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 17: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 18: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 19: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 20: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 21: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 22: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 24: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. doc: Cond -10/06 D07 -439 Printed: 04 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 25: Local U.L. central station supervision is required. (City Ordinance #2051) 26: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 30: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 33: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** D07 -439 Printed: 04 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: / Date: V � � g Print Name: doc: Cond -10/06 007 -439 Printed: 04 - 08 - 2008 E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: /%www. ci. tukwila. Wa. us Q: Wpplications\Fams- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bit Building Permit No. ! 1) 0 2-1 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. ?b1-" 1 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2 62 3Q -‘1030-o81.117 Site Address: ‘12 H CE Nit re. Pkwy Suite Number: 12 2 Tenant Name: PA y L E SS 5 Ho ES Property Owners Name: W I G Pao P E K'ri ES L L C - SS Mailing Address: li $ j 13 4 ( 1- 1/ PL • SE Contractor Registration Number: f�E LCEVvE City Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: W/} State State State Floor: New Tenant: Yes ❑..No 6(S 006 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Co RwEL Po1a,RvET /Me iHE(T$Nn AECiti?EC?$ Day Telephone: 1 12 5- 32/ - 21 00 Mailing Address: 1 30 WE. ?ow l-5 -5 bl -ZvE t Sv1TEgoo . KileKLAND WA 4 111 0 33 City State Zip o eu ra vet @ ekoarck . COth Fax Number: 425 - 1. 2 4 " 6$ GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: T. $ .1) . Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: 12Ei NE1 T R N0 AQC ttiTFC TS I 14 • P. S. Mailing Address: 10210 NE P0INic-a bRWVE So ITF Soo KIRIGLAAID, WA 49$033 City State Zip Contact Person: C or n eL Pk/ ra v¢ t Day Telephone: 425 - $2? — 2 100 E -Mail Address: G ev rot V et ( f . Cool Fax Number: 1 1 25 - $ 23 - 6Set q ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Zip Page 1 of 6 BUILDING PERMIT INFORMATION = 206- 431 -3670 Valuation of Project (contractor's bid price): $ 100, Dbo Scope of Work (please provide detailed information): 1 N SIA L.L. I iv' a Iti o R 1,00a ANI. W /1 L. L. F lW$TALi- DIS PLA, FiX9✓ics.5 cnEck - o'r Pre / a>%'GTC 'Ft) gpt'fu ICS AND 5It .vilG ? vl bs ELEc)i (A2 Cor" C Paz CAs14 2E(rTs S • Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 8 Sprinlders Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Jg No If `yes ; attach list of materials and storage locations on a separate 8 -1/2 "x II "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\ Applicerions\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised 9 -2006 bh Existing Building Valuation: $ -' 2.5 Kt' Lc i oN X .. No If yes, a separate permit and plan submittal will be required. Other (specify') EXIST) N G S y 57E M Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l't Floor; li 6 t 61( 2,Ct4$ O Y - B M 2nd Floor 3rd Floor Floors thru Basement Accessory Structu Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION = 206- 431 -3670 Valuation of Project (contractor's bid price): $ 100, Dbo Scope of Work (please provide detailed information): 1 N SIA L.L. I iv' a Iti o R 1,00a ANI. W /1 L. L. F lW$TALi- DIS PLA, FiX9✓ics.5 cnEck - o'r Pre / a>%'GTC 'Ft) gpt'fu ICS AND 5It .vilG ? vl bs ELEc)i (A2 Cor" C Paz CAs14 2E(rTs S • Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 8 Sprinlders Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Jg No If `yes ; attach list of materials and storage locations on a separate 8 -1/2 "x II "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\ Applicerions\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised 9 -2006 bh Existing Building Valuation: $ -' 2.5 Kt' Lc i oN X .. No If yes, a separate permit and plan submittal will be required. Other (specify') EXIST) N G S y 57E M Page 2 of 6 BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: Q: Applications\Forms- Applications On Line\3 -2006 - Permit Application. doe Revised 9-2006 bh PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: i l CORN 5 L p, 9Avt .T Day Telephone: 1125 $ 21 ' 2 t°° to23o NE PolnrTS b9-)ve , sut ?E 30o ®KlgKLA$b wA - State ( 43°33 Zip Date Application Accepted: I 1....,p `o 7 Date Application Expires: 5-A-0 g Staff Initials: v i< i Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 2623049117 Permit Number: D07 -439 Address: 17250 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 11/29/2007 Applicant: PAYLESS SHOES Issue Date: Receipt No.: R08 -01080 Initials: JEM User ID: 1165 Payee: CONSTRUCTION EXPEDITING SERVICES, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5600 1,236.48 ACCOUNT ITEM LIST: Description BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 RECEIPT Account Code Current Pmts Total: $1,236.48 Payment Amount: $1,236.48 Payment Date: 04/08/2008 01:48 PM Balance: $0.00 1,231.98 4.50 i 7w 04/08 "711 Oi} 1:30.43 doc: Receipt -06 Printed: 04 -08 -2008 Receipt No.: R07 -02610 PLAN CHECK - NONRES Payee: FREIHEIT AH HO ARCHITECTS INC ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049117 Permit Number: D07 -439 Address: 17250 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/29/2007 Applicant: PATLESS SHOES Issue Date: Initials: WER Payment Date: 11/29/2007 09:34 AM User ID: 1655 Balance: $1,236.48 TRANSACTION LIST: Type Method Description Amount Payment Check 18464 800.79 Account Code Current Pmts 000/345.830 800.79 Total: $800.79 Payment Amount: $800.79 5475 11/29 9710 TOTAL 800.79 doc: Receiot -06 Printed: 11 -29 -2007 Proje19 ( Type,gf Ins�ec� ion: /' J v Address: nu a So ��� ! i � < r. Date �I led: Special Instru ions: Date Wed: y -q-- dCl a p m. Requester: Phone No: X07 - 43 c INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - Approved per applicable codes. El Corrections required prior to approval. COMMENTS: t V Inspect r: ` Aipj Dat tr . $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit Project: a, Lc -s s Type Inspection: Address: l7 2 S v Svt.rr�+c,tv,1 ;zZ Kf Suite #: )76 Contact Person: M k IC E Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWIL.A FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 COMMENTS: c 2 c '� �� 14 - U (� Inspector: Jo p b S CZ- Date: L I is I rs.: Jf Aroved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 n Corrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 04 -04 -2008 CORNEL PURAVET 10230 NE POINTS DR SUITE 300 KIRKLAND WA 98033 RE: Permit Application No. D07 -439 17250 SOUTHCENTER PY TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 11/29/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 05/27/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 05/27/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, J?<nni�r Marshall Pe Technician xc: Permit File No. D07 -439 City of Tukwila Department of Community Development Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: c 11 iii1) I [Bain • , 'vision PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -439 DATE: 11 -29 -07 PROJECT NAME: PAYLESS SHOES SITE ADDRESS: 17250 SOUTHCENTER PY X Original Plan Submittal _ Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued 5I( "09() (i'1 Fire Prevention X. P b is Works Structural 5 41 I - DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2- 28-02 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions P CT3 I�4t anning Division Permit Coordinator DUE DATE: 12 -04 -07 Not Applicable ❑ No further Review Required n Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 01 -01 -08 Not Approved (attach comments) LI Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License CONSTES944B3 Licensee Name CONSTRUCTION EXPDTNG SRVCS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602468049 Ind. Ins. Account Id #1 Business Type CORPORATION Address 1 13620 LINCOLN WAY 3210 Address 2 City AUBURN County OUT OF STATE State CA Zip 95603 Phone 5308852200 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/23/2006 Expiration Date 1/23/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 DEVELOPERS SURETY & INDEM CO 740059C 01/17/2006 Until Cancelled $12,000.00 01/23/2006 Business Owner Information Name Role Effective Date Expiration Date WILLER, PERRY PRESIDENT 01/23/2006 Look Up a Contractor, Electric ; an or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 2 https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= CONSTES944B3 04/08/2008 4. 5. 6. SQUT 11250 SQST eN= AL NOTES ALL WORK AND BIDDING SHALL REFLECT AND CONFORM TO ALL LOCAL AND STATE BUILDING CODES, ORDINANCES, AND BUILDING INSPECTIONS AND BE ENFORCED BY THE CONTRACTORS AT ALL TIMES. 2. CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND REQUIREMENTS. CONTRACTOR SHALL CONTACT LANDLORD'S REPRESENTATIVE TO VERIFY AND COORDINATE ANY SPECIAL CONDITIONS, REQUIREMENTS, AND RESPONSIBILITIES. CONTRACTOR SHALL ALSO REVIEW ANY TENANT HANDBOOKS AND COMPLY WITH ALL REQUIREMENTS THEREOF. PRIOR TO SUBMITTING HIS BID THE GENERAL CONTRACTOR SHALL CAREFULLY STUDY ALL DRAWINGS AND VERIFY EXTENT OF DEMOLITION WORK (IF REQUIRED) WITH TENANT'S FIELD COORDINATOR. CONTRACTOR SHALL BE RESPONSIBLE FOR FLOOR PATCHING, LEVELING, AND PREPARATION FOR AND OF FLOOR FINISHES. ALL MATERIALS, EQUIPMENT, AND FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SUGGESTED INSTALLATION SPECIFICATIONS. CONTRACTOR SHALL USE GYPSUM BOARD OF THICKNESS NOTED AND WITH TAPERED EDGES. ALL OUTSIDE CORNERS SHALL HAVE METAL SCREWS, CASING BEADS OR CORNER BEADS AS REQUIRED. TAPE ALL JOINTS, BED, AND SAND SMOOTH IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SMOOTH SURFACE TO RECEIVE PAINT. SCREW GYPSUM BOARD TO BACKING. 7. CONTRACTOR SHALL VERIFY BUILDING DEPARTMENT PROCEDURES FOR OBTAINING ALL. PERMITS PRIOR TO SUBMITTING BIDS, CONTRACTOR SHALL PAY FOR ALL NECESSARY PERMITS AND /OR FEES REQUIRED BY PUBLIC, AUTHORITIES AND /OR UTILITY COMPANIES AND ALL TEMPORARY POWER COSTS. ANY TIE -IN OR INSPECTION FEES TO BE INCLUDED IN BID. CONTRACTOR TO VERIFY IF WATER OR OTHER METERS ARE REQUIRED BY LANDLORD, UTILITY COMPANY, OR BUILDING DEPARTMENT. ALL ASSOCIATED COSTS FOR SAME TO BE INCLUDED IN BID. 8. GENERAL CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION, BARRICADES, AND /OR CANOPIES AS REQUIRED BY THE LOCAL AUTHORITIES OR AS NECESSARY FOR PEDESTRIAN SAFETY. 1. GENERAL CONTRACTOR SHALL PROVIDE AND HANG FIRE EXTINGUISHERS AND MISCELLANEOUS ITEMS PER TENANT'S OPERATIONS DEPARTMENT OR AS DIRECTED BY LOCAL FIRE DEPARTMENT OFFICIAL. 10. ALL CONDITIONS DESCRIBED IN GENERAL NOTES SHALL BE INCLUDED IN BID. II. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR SHALL NOTIFY TENANT IMMEDIATELY UPON ANY /ALL DISCREPANCIES. 12. ALL SPRINKLER WORK MODIFICATIONS SHALL BE COORDINATED WITH ALL OTHER TRADES ON SITE. CONTRACTOR IS RESPONSIBLE FOR ALL SPRINKLER WORK INCLUDING ALL UPGRADES AND MODIFICATIONS, ALL RISERS AND HEADS. ALL SPRINKLER WORK SHALL ACCOMMODATE TENANT APPROVED CONSTRUCTION DRAWINGS AND SPECIFICATIONS. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO LANDLORD, BUILDING, AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. (IF APPLICABLE). 13. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LEAVING PREMISES IN CLEAN CONDITION, READY TO ACCEPT MERCHANDISE. 14. GENERAL CONTRACTOR SHALL VERIFY WITH LANDLORD REQUIREMENTS TO TIE INTO SHOPPING CENTER FIRE ALARM SYSTEM (SMOKE EVACT. SYSTEM IF REQUIRED) AND DETERMINE WHO IS TO FURNISH ALL REQUIRED EQUIPMENT. ALL CONTRACTOR COSTS ARE TO BE COVERED IN BID. (IF APPLICABLE) 15. ABSOLUTELY NO ASBESTOS OR ASBESTOS CONTAINING MATERIALS SHALL BE USED IN THE CONSTRUCTION OF THIS PROJECT. 16. ALL REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT AND ANY LOCAL ACCESSIBILITY CODES SHALL BE ADHERED TO. WHEN IN CONFLICT, THE MORE STRINGENT OF THE TWO STANDARDS SHALL GOVERN. 17. THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SUBMITTALS ARE DEFERRED AND MUST BE SUBMITTED SEPARATELY (IF APPLICABLE). WNTRACTQ N = ORATION ARCHITECTURAL PROJECT MANAGER: PROJECT MANAGER: UNION: CONSTRUCTION START: CONSTRUCTION COMPLETE: CONSTRUCTION DURATION: LOCATION: JENNIFER 5OETTCHER (185) 270 -1620 JLrr WYLIE (785) 210 -1665 SOUTHGENTER SQUARE 11250 SOUTHGENTER PARKWAY, SUITE 126 TUKWILA, WA IT IS A VIOLATION OF THE LEASE TO FAIL TO CONSTRUCT THIS PROJECT ACCORDING TO THE "TENANT PACKAGE" REQUIREMENTS (TENANT DESIGN AND CONSTRUCTION CRITERIA, CONSTRUCTION RULES AND REGULATIONS FOR TENANT'S CONTRACTOR, AND SIGN DESIGN AND CONSTRUCTION CRITERIA). ANY DEVIATION FROM THE CRITERIA OR THESE CONSTRUCTION DOCUMENTS MUST HAVE THE TENANT COORDINATOR'S SPECIFIC WRITTEN APPROVAL. STORE #I123 °Gee TER SUAR °G_NTeR FAKAA', SUTE 128 TUKALA AA TENANT: LANDLORD: AREA CALCULATIONS: CONSTRUCTION TYPE: OCCUPANCY CLASSIFICATION: OCCUPANCY CALCULATIONS: GOVERNING CODES: BUILDING DEPARTMENT: ARCHITECT/ PROJECT CONSULTANT: A.B. A.G.T. A.F.G. A.F.F. B.M. CKT. G CLG. CONC. CONT. CPT. DN. DIA_ DWG. EA. E.F. EL. ANCHOR BOLT ACOUSTICAL CEILING TILE ABOVE FINISH CEILING ABOVE FINISH FLOOR BRAKE METAL CIRCUIT CENTERLINE CEILING CONCRETE CONTINUOUS CARPET DOWN DIAMETER DRAWING EACH EACH FACE ELEVATION iN vATIpN PAYLESS SHOESOURCE CORPORATE HEADQUARTERS 120 S.E. 6TH STREET TOWNSITE PLAZA BUILDING #2, SUITE 102 TOPEKA, K5. 66605 P.O. BOX 5591 TOPEKA, K5. 66601 -3511 PHONE: (785) 233 -5171 JEFF WYLIE, CONSTRUCTION PROJECT MANAGER PHONE: (785) 210 -7565 EMAIL: Jeff_WyIIe @payless.com WIG PROPERTIES, LLC 4811 -134TH PLACE 5E BELLEVUE, WA (425) .157 -4714 ATTN: LESITYA WIG SALES AREA 101 = 2,522 5.F. OFFICE 102 = 515 5.F. HALLWAY 103 - 177 5.F. TOILET ROOMS 104 = 134 5.F. TOTAL = 2,148 5.F. TYPE V -B (FULLY SPRINKLERED) M MERCANTILE NUMBER OF EMPLOYEES NOT TO EXCEED (4) AT ANY TIME PUBLIC AREAS: 2,522 5.F.÷ 30 = 77 NON PUBLIC. AREA: 626 5.F. + 300 = 2 TOTAL: = 71 ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: BUILDING: ELECTRICAL: PLUMBING: MECHANICAL: FIRE: HANDICAP: 2006 IBC W/ WA STATE AMENDMENTS 2005 NEC 2006 UPC 2006 IMO 2006 I FG 2006 IBC IN/ WA STATE AMENDMENTS CITY OF TUKWILA BUILDING DIVISION 6300 SOUTHGENTER BOULEVARD, SUITE 100 TUKWILA, WA .16188 206 - 431 -3610 FREIHEIT AND HO ARCHITECTS, INC., P.S. 10250 NE POINTS DR., SUITE 500 KIRKLAND, WA 98035 (425) 821 -2100 ATTN: TOM SPADER ELC. EXIST. EXP. F.R. F.T. FIN. GA. GYP.BD. G.G. GALV. GL. HOW. HGT. H.M. H.P. H.A.G. INLAND. ELECTRICAL CONTRACTOR EXISTING EXPANSION FIRE RETARDANT FIRE TREATED FINISH (ED) GAUGE GYPSUM BOARD GENERAL CONTRACTOR GALVANIZED GLASS HARDWARE HEIGHT HOLLOW METAL HI GHPOI NT HEATING $ A/C CONTRACTOR INCANDESCENT SEPARATE PERMIT REQUIRED FOR: echanical I.v E lectrical F P lumbing G as Piping Cit of Tukwila BUIL N DIVISION _________________________ REvisioNs No chances sh�!ll b r arTrl thn ccnn�, of work , vithoui rC) : ,� , ;;•.ti,� n:Il f I_ Tukwila i J 1 )Il. i i oj i N OTE: Revisions will requife d i ew;v pInn sulbrnit+ryl and may include additional olds review fees SEPARATE PERMIT AND APPROVAL REQUIRED SALES AREA JT. LAY. L.P. MAS. MAX. MIN. MR. M.R. MT. N.I.C. NO. O.G. D.H. OPN'G P.B.G. P.G. PBS ROOM NAME NORTH KEY NOTE COLUMN NUMBER AND GRID LINE JOINT LAVATORY LOW POINT MASONRY MAXIMUM MINIMUM MIRROR MOISTURE RESISTANT METAL NOT IN CONTRACT NUMBER ON CENTER OVERHEAD OPENING PLUMBING CONTRACTOR PLATE GLASS PAYLESS SHOESOURCE FILE COPY Permit No..,,„ Pier review approval is subject to errors and omissions, of approv FIL • ' Approval of construction does notautho�a the violation of any added code or ordinance. Receipt 4 ' r � By t/A3 D City of Tukwila BUILDING DIVISION 1:7AAINS NEX CO COVER SHEET Al FLOOR PLAN AI.I FLOOR FINISH PLAN/FINISH SCHEDULE A2 REFLECTED CEILING PLAN AS EXTERIOR ELEVATIONS AND SIGN DETAILS A3.I EXTERIOR $ INTERIOR ELEVATIONS A3.2 INTERIOR ELEVATIONS A4 SECTIONS/DETAILS AS SPECIFICATIONS A5.I SPECIFICATIONS A5.2 SPECIFICATIONS A5.5 SPECIFICATIONS M -I GENERAL NOTES, SPECIFICATION, SCHEDULE LEGEND M -2 HVAG PLAN P -I PLUMBING PLAN E -I POWER PLAN E -2 LIGHTING PLAN E -3 DETAILS L ::4 LIGHTING ENERGY FORMS )1) ST'VEOL LEGEND 2 DETAIL NO. SHEET LOCATION DOOR NO. A65EVATONS P.L. PLY'D PT. RAD. R.B. RE: REQ'D 5T. T/S T.G. TYP. Y.I.F. U.N.D. V.G.T. W/ WD. WOOD c9 AT SECTION NO. SHEET LOCATION ELEVATION DESIGNATION PLASTIC LAMINATE PLYWOOD PAINT RADIUS RESILIENT BASE REFERENCE REQUIRED STEEL TOP OF STEEL TEMPERED GLASS TYPICAL VERIFY IN FIELD UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE WITH . COVED Nov 2 9 2001 PERMIT CENTER VICINITY MAP .•.•.•.. WEST.FI.ECD'.:: ': :: 61.1bPpINGTOWN " :. BLVD < PLAN PAYLESS SHOESOURC NOTE: TEAM MEMBERS: ARCHITECTURE: HVAG /PLUMS.: ELECTRICAL: QUAL ITY ASSURANCE: NORTH STREET THIS DESIGN CRITERIA I5 PROVIDED FOR SUILDIN6 OFFICIAL REVIEW CONVENIENCE ONLY AND 15 NOT INTENDED FOR USE BY COMPONENT DESIGNERS OR MANUFACTURES A5 THEIR SOLE DESIGN CRITERIA WITHOUT VERIFICATION. EACH DESIGNER AND /OR MANUFACTURER MUST INDEPENDENTLY CONFIRM ALL CODE CRITERIA WITH WHICH HI5 ELEMENTS OR COMPONENTS MUST COMPLY, INCLUDING BUT NOT LIMITED TO LOADING, APPLICATION, FUNCTIONALITY, TEC. PERFORMANCE CRITERIA PROVIDED ELSEWHERE BY A SPECIFIC DISCIPLINE SHOULD BE REGARDED AS THE MINIMUM STANDARDS ACCEPTABLE TO THE CLIENT. EACH SUPPLIER MUST EVALUATE THESE MINIMUMS AGAINST SPECIFIC INDUSTRY STANDARDS A5 WELL AS CODES, LAWS, ORDINANCES, AND UNDERWRITER REQUIREMENTS GOVERNING HIS PRODUCT A5 WELL AS OWNER INSURER REQUIREMENTS, AS APPLICABLE. THE MOST STRINGENT OF THESE CRITERIA SHALL GOVERN. THE FOLLOWING I N D I V I D U A L S WERE TEAM MEMBERS INVOLVED IN THIS PROJECT UNDER THE DIRECT SUPERVISION OF THEIR RESPECTIVE PROFESSIONAL of RECORD: TOM SPADER STEVE HOWARD JAY WERNER TOM SPADER NORTH NORTH Project North R e v i s i o n s 0 ■— ■- ■� ■=1111 ■� Date 11/2 Description OWNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 IIRKlAND, WA 98033 1M25.8272100 F:425.828.6899 T HOMAS LE - SPADER STATE (): \' ".SHINGTON STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA COVER SHEET DRAWN BY: CP DRAWING NAME: 07652CO.dvig DATE: 1 1/21/07 PROJECT NO.: A01 -652 1)0 LI 3/ ■ ■ • • • ■ ■ ■ ■ ■ • • ■ ■ ■ ■ ■ ■ TOILET ■ ■ ■ ■ ■ • • • ■ ■ ■ ■ ■ • ■ • • ■ ■ ■ HALLWAY TOILET 4' -10" 5' -10" ' -11 I /S" Play Zone 48'-4" 10' -1 5 /S" m �3 H�►ndbag 5' -10 7/8" FLOOR PLAN OFFICE 7 1/4" 13' -I 13/4" 4 7 /a" EXISTING CANOPY MEN'S BUNDLE FIXTURE PROVIDED BY P55, INSTALLED BY G.G. HOT ZONE DISPLAY FIXTURES PROVIDED BY PS5, INSTALLED BY G.G. EXISTING STOREFRONT. STOREFRONT DOOR PER SCHEDULE STORE ENTRY MAT - SEE DETAIL 4/A4 FIN END PANEL PROVIDED BY P55, INSTALLED BY G.G., G.G. TO GUT HAILERS @ FIN LOCATIONS. DISPLAY PANEL PROVIDED BY P55, INSTALLED SY G.G. PREFABRICATED WING WALL PROVIDED BY PSS, INSTALLED BY G.G. NER -2I I - ER -2156 - ER -2388 51 - ER -4627 - ER -1820 - FATTQN SG EXISTING CONSTRUCTION 43' -0" I06' -2 5/8" LEASE DIMENSION BY LANDLORD - 2 1/2" MTL STUDS @ I6" 0.C. W/ 5/8" TYPE 'X' GYP. BD. INTERIOR SIDE ONLY TO 6" ABOVE CEILING. ALIGN N1/ ADJACENT WALLS BY LANDLORD - 3 1/2" MTL STUDS @ 16" O.G. W/ 5/8" TYPE 'X' GYP. B. BOTH SIDES TO 6" ABOVE CEILING. BRACE AT 8' -0" 0. G. W/ 3 1/2" MTL. STUD @ 45° TO ROOF STRUCTURE ABOVE BY LANDLORD - 6" MTL STUDS @ 16" O.G. W/ 5/8" TYPE 'X' W. BD. BOTH SIDES TO 6" ABOVE CEILING. M.R. AT TOILET ROOM) BRACE AT 8' -0" 0. C. IN/ 3 1/2" MTL. STUD @ 45° TO ROOF STRUCTURE ABOVE 41' -5" METAL STUDS - UM -MAST HKT -14 KWIK -BOLT CONCRETE ANCHORS - HILTI, INC. HILTI LOW - VELOCITY DRIVE AND PNEUMATICALLY DRIVEN FASTENERS - HILTI, INC. KWIK- BOLT -II AND POST NUT KWICK- BOLT -II - HILTI, INC. SHEETROCK BRAND WATER - RESISTANT GYPSUM PANELS - UNITED STATES GYPSUM CO., CHICAGO, IL. 6I' -I0 I /8" 51' -3" IC/E0 NUV5S NOTES: MISC. HARDWARE @DOOR #3 ONLY FLOOR OR WALL STOP LOCKSET HINGES SADDLE THRESHOLD CLOSER SMOKE 4 DRAFT ASSEMBLY FLOOR OR WALL STOP LOGKSET HINGES CLOSER LOCKSET CLOSER HINGES THRESHOLD WEATHERSTRIPPING PEEPHOLE PULL. HANDLE DOOR BOTTOM FLOOR AND WALL STOP SMOKE $ DRAFT ASSEMBLY REMARKS Kids, /_ \,Kids WOMENS ARE 5G In Rack Clearance Handbaa LARGE GRAPHIC PROVIDED BY P55, INSTALLED BY G.G. GRAB BARS BY LANDLORD. SEE DETAIL 3/A4. SUPPLY SHELF PROVIDED AND INSTALLED BY G.G. FOR ACCESSORIES, FINISHES, ETC., SEE SPECS. - PROVIDED BY LANDLORD. TOILET 4 LAVATORY BY LANDLORD. SEE DETAIL 3/A4. DRINKING FOUNTAINS BY LANDLORD. MOP SINK PER SPECIFICATIONS. 5' -10 5/8" In Rack °L002 PLAN <Er'Et7 NOTES CIQNT FIRE EXTINGUISHER BY LANDLORD (PER CODE AND /OR CODE OFFICIAL) LOCATIONS TO BE DETERMINED AT FINAL INSPECTION. REFER TO SPECIFICATIONS. SEE GENERAL NOTE #q ON SHEET CO. L.L. TO PROVIDE AND INSTALL GLASS STOREFRONT SYSTEM. 3' -O" X T -0" DOUBLE ENTRY DOOR IN/ TRANSOM TO INCLUDE: BASE, BOTTOM AND HEAD RAILS, CORNER CLIPS, GLASS CLIPS, DOOR PIVOTS, LOCK HOLDERS, DOOR STOPS $ PUSH/PULLS PER SPECIFICATIONS. GLYNN- JOHNSON 1I53M SCHLAGE "5" SERIES SIOD (PASSAGE) 3 -4 1/2 X 4 1/2 X US26D BB BUTTS MACKLANBURG- DUNCAN #11072 (HEAVY -DUTY, FLAT TOP) I/4 "x2 I/2 "x36" ALUMINUM CORBIN- RUSSWIN *DC2200 XUS260 - WHEN APPLICABLE TRIM PROTECTOR BAR 42" - MODEL#RIIILFB (6" BELOW LATGHSET) SUPPLIED BY G.G. (3) BOSTON BUMPERS W/ ALUM. CHANNEL $ END GAPS. (SERIES 40) COLOR #18 SUPPLIES BY P55. INSTALL AT ELEVATIONS AS SHOWN ON SHEET A3.I 3' -11" FEMKO 305CR (PROVIDE DOOR ASSEMBLIES W/ GASKET INSTALLED AS TO PROVIDE A SEAL WHERE THE DOOR MEETS THE STOP ON BOTH SIDES $ ACROSS TOP) BY G.G. GLYNN - JOHNSON 1153 M SCHLAGE "5" SERIES 540D (TOILET) 3 -4 1/2 X 4 1/2 X U526D 55 BUTTS CORBIN- RUSSWIN #002200 XU5260 PHOENIX 4017-01 (PANIC HARDWARE) IN/ SCHLAGE CORBIN - RU55WIN DC 2200 SERIES X US26D 3 -4 1/2 X 4 1/2 X U5260 BB BUTTS W/ N.R.P. PEMKO #271A PEMKO 305GR -- WHEN APPLICABLE RESIDENTIAL TYPE MOUNTED @ 5-0" A.F.F. SGHLAGE - SERIES 5170 X 115261, (HALF - DUMMY) PEMKO #222AV IVES 445/446 OR 40214 (408 - WHEN APPLICABLE PEMKO 305GR (PROVIDE DOOR ASSEMBLIES W/ GASKET INSTALLED AS TO PROVIDE A SEAL WHERE THE DOOR MEETS THE STOP ON BOTH SIDES $ ACROSS TOP) BY G.G. ALL HARDWARE FINISHES SHALL BE SATIN CHROME FINISH U526D EXCEPT FOR CLOSURES WHICH SHALL BE SPRAYED FINISHED TO MATCH DOOR COLOR. ALL LOCK SETS SHALL HAVE STANDARD 2 3/4" BACKSET AND I I/8" X 5" STRIKE PLATES, DEAD BOLTS SHALL BE I" THROW. SUPPLY A TOTAL OF (5) KEYS FOR SETS A 4 D SHALL HAVE SAME KEYING. =LOOS PLAN <=1)'== NQTS QN'T 16' -5" ANELS I2' -3" DOOR SEULE ELECTRICAL PANEL BY LANDLORD (SEE ELEC. DINGS.) PHONE BOARD BY LANDLORD (SEE ELEC. DINGS) LOCKERS PROVIDED BY PS5, INSTALLED BY G.G. GOAT RACK PROVIDED BY P55, INSTALLED BY G.G. OFFICE FIXTURES PROVIDED BY P55, INSTALLED BY G.G. MOVEABLE CART PROVIDED AND INSTALLED BY P55. DESK, FILE CABINET, AND COMPUTER STAND PROVIDED BY P55, INSTALLED BY G.G. CHAIR PROVIDED BY P55, INSTALLED BY G.G. OFFICE SHELVING ABOVE @ T -2" A.F.F. (SHOWN DASHED) PROVIDED BY P55, INSTALLED BY G.G. cart cart cart cart PLAN <Er'EI; NOTES 34" HIGH CHECK OUT COUNTER SUPPLIED BY P55, INSTALLED BY G.G., ELECTRICAL CONTRACTOR TO INSTALL COUNTER OUTLETS AS SHOWN ON SHEET E3, OUTLET BOX TO BE LOCATED AT I' -6" KIDS PLAY ZONE FIXTURES PROVIDED BY P55, INSTALLED BY G.G. I' -6" X q' -O" PREFABRICATED CORNER SOX PROVIDED BY P55, INSTALLED BY 6.C. DISPLAY FIXTURES SUPPLIED BY P55, INSTALLED BY G.G. END PANEL AND MIRROR PROVIDED BY P55, INSTALLED BY G.G. END PANEL PROVIDED BY P55, INSTALLED BY G.G. END TABLE PROVIDED BY P55, INSTALLED $Y G.G. IN RACK MIRROR PROVIDED SY P55, INSTALLED BY 6.C. COLUMN, PAINT (P -I) W/ 4" RUBBER BASE (RB -I) G'ENEAL CONTRACTOR SHALL HOW ALL SALES AREA DIMENSIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE PAYLESS SHOE PROJECT MANAGER. 2. FIELD VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING CONSTRUCTION. NOTIFY P55 PROJECT MANAGER AND PROJECT CONSULTANT OF ANY DISCREPANCIES. 3. G.G. TO REFER TO SPECIFICATION SHEET (A5) TO DETERMINE WHETHER A RESPONSIBILITY 15 BY LANDLORD, BY TENANT (P55), BY TENANT'S G.G. OR AN EXISTING CONDITION. NOTIFY P55 PROJECT MANAGER AND PROJECT CONSULTANT OF ANY DISCREPANCIES. 4. ALL METAL STUDS TO BE 362 SJ 20 UNLESS NOTED OTHERWISE. REFER TO SHEET A2 AND A3.I FOR CEILING HEIGHTS A BARRIER FREE SERVICE COUNTER SHALL BE PROVIDED 5. USE (4) NO. 1/4 - 14 SHEET METAL SCREWS A EACH METAL STUD TO METAL STUD CONNECTION 8. A (5# ABC) FIRE EXTINGUISHER SHALL BE PROVIDED PER 2005 FIRE CODE ANY MODIFICATIONS TO THE SPRINKLER SYSTEM WILL NEED TO BE APPROVED BY THE FIRE DEPARTMENT. 10. THRESHOLDS: CHANGES IN LEVEL UP TO 1/4" NEED NO EDGE TREATMENT: CHANGES IN LEVEL BETWEEN 1/4" AND 1/2 " SHALL BE A RAMP NO STEEPER THAN I" VERTICAL TO 2" HORIZONTAL. 11. DISPLAY FIXTURES: ALL DISPLAY FIXTURES ARE 52" (6' -10 ") IN HEIGHT 12. ALL REUSED MATERIAL AND EQUIPMENT MUST BE REFURBISHED TO "LIKE NEW" CONDITION. 13. CONTRACTOR TO PILL AND LEVEL ALL FLOOR AREAS AS REQUIRED IN ACCORDANCE WITH SPECIFICATION 03346. DESCRIPTION GLASS ENTRY DOORS NOTES: 3' - X 7' -0" X 1 3/4" 3' -6" XT-0" X 1 3/4" HOLLOW METAL FLUSH SLAB (BY LANDLORD) HOLLOW METAL FLUSH SLAB (5Y LANDLORD) I. HARDWARE TO BE LEVER TYPE AT INTERIOR DOORS, ALL PANIC HARDWARE SHALL BE INSTALLED WITH ACTIVATING MEMBER MOUNTED AT A HEIGHT NOT LESS THAN 30" OR MORE THAN 44" A.F.F. UNLATCHING FORCE SHALL NOT EXCEED 5 LBS. ON INTERIOR DOORS OR 55 LBS. FOR EXTERIOR DOORS IN DIRECTION OF EXIT TRAVEL. EXIT DOORS SHALL SE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 2. G.G. TO PROVIDE A READILY VISIBLE, DURABLE SIGN ABOVE ALL EXIT DOORS STATING "THIS DOOR SHALL REMAIN UNLOCKED DURING BUSINESS HOURS." THE SIGN SHALL BE IN LETTERS NOT LESS THAN I" HIGH ON A CONTRASTING BACKGROUND IF REQUIRED BY CODE. 3. G.G. TO PROVIDE HANDICAP UNISEX SIGN ON DOOR #4 AS REQUIRED. 4. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES ON DOORS SHALL HAVE A SHAPE THAT 15 EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. LEVER - OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U- SHAPED HANDLES ARE ACCEPTABLE DESIGNS. 5. PAINT DOORS #3, 4, 4 5 (P -I) BOTH SIDES. PAINT DOOR #2 (P -I) TENANT SIDE ONLY.' C ( D 6. ALL DOORS SHALL COMPLY WITH 2003 ANSI A117.1 -404 NOV 2 9 2007 1. SEE DETAIL 5/A4. PERM T CENTER 6' -o" X T -0" 3' -O" XT-0" X 1 3/4" 3' -0" X 7'-0" X 1 3/4" DESCRIPTION I HARDWARE 1 GLASS ENTRY DOOR (EXISTING) HOLLOW METAL FLUSH SLAB (EXISTING) HOLLOW METAL FLUSH SLAB (BY LANDLORD) A B AL Project North Revisions N Date 11/21/01 Description GINNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 MOUND,. WA 98033 P:425.8272100 F:425.828.6899 STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA FLOOR PLAN DRAWN BY: GP DRAWING NAME: 01652AI DATE: I I/27/07 PROJECT NO.: A01 -652 FLOORING PLAN 1/4" : 1,_0" TOILET 104 HALLWAY 105 OFFICE 102 F -3 TOILET 104 ciEr eP CARPET SALES LUXURY VINYL CARPET / VINYL TILE TRANSITION, SEE DETAIL 6 /A4 Pu �n 010 — LUXURY VINYL TILE: PRODUCT:T.B.D. 5A5E: 5EE R5-I; NOTES: P55 PROVIDED, GC INSTALL BASE PAINT F -5 Y.G.T. F -I2 RB-I P -1 P -IE SALES AREA 101 OFFICE 102 HALLWAY TOILET 104 CARPET TILE: PRODUCT: INTERFACE FLOR, URBAN GRID CARPET. CARPET STYLE: *16 1I5 TUFTED TEXTURED LOOP; COLOR/PATTERN: 5425 STEEL; INSTALLATION TYPE: TAG TILE; BASE: SEE RB-I NO i : - 5 _ ;*YID + G NST . L ARMSTRONG #51111; COLOR: CLASSIC WHITE SUPPLIED AND INSTALLED BY CONTRACTOR (0.5.H.A. YELLOW) EMERGENCY EXIT STRIPPING AS REQUIRED BY CODE. RESILIENT BASE: ROPE; HEIGHT: 4 "; CONFIGURATION: COVED; COLOR: DARK GRAY PI50 �HERAIN WILLIAMS - S111006 EXTRA WHITE - EG -OHEL FINISH ON WALLS SEMI -GLOSS FINISH ON DOORS/TRIM SHERWIN WILLIAMS - CATALYZED EPDXY LATEX PAINT VERSION PROMAR 200 LATEX, 5WT006 EXTRA WHITE - E6-SHEL FINISH. SHERWIN WILLIAMS - SW66S5 DETERMINED ORANGE - EGGSHELL FINISH NOTES: LOCATION: SALES FLOOR BEHIND CASH WRAP CEILING CF -I ACOUSTIC CEILING TILE: ARMSTRONG, PRODUCT: FINE FISSURED; PRODUCT NUMBER: 1125; SIZE: 2'x4'xE /5' EDGE DETAIL: SQUARE LAY -IN; COLOR: WHITE; SUSPENSION SYSTEM: PRELUDE XL 15/16 INCH, #'730!, WHITE. NOTES: NOT ALL ITEMS LISTED ARE INCLUDED IN EVERY STORE PACKAGE BUT MAY BE PERTINENT- IN REGARDS TO FIXTURE AND FINISH PACKAGE. + ?' NOV 29nut ROOM NAME FLOOR WALL BASE CEILING MATERIAL PERMIT GEN E ROO V SC/ CEILING HEIGHT CARPET TILE (FC -I) VINYL TILE (FC -2) Y.G.T. (F -5) V.G.T. (F -5) V.G.T. (F -3) PAINT (P -I) PAINT (P -2) 4" RUBBER COVE BASE (RB-I) 4" RUBBER COVE BASE (R15-I) 4" RUBBER COVE BASE (RB-I) 4" RUBBER COVE BASE (RB-I) A.G.T. (CF -I) A.G.T. (CF -I) A.G.T. (CF -I) GYP. BD. (P -I) SALES SALES NON -SALES SALES /OFFICE HALLWAY TOILET WALLS DOORS/TRIM WALLS DOORS/TRIM WALLS SALES OFFICE HALLWAY II' I I' - O" Ill 0 " 5' -O" Project North Revisions 0 • ■11111111 • - • ■ Date I I /21/01 All • Description OWNER REVISION FREIHEIT & H O ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRKLAND, WA 98033 P:425.827.2100 F :425.828.6899 THOMAS LE?O SPADE'? STATE OF l "I;SI :AGTON STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA FLOOR FINISH PLAN AND SCHEDULE DRAWN BY: CP DRAWING NAME: 01652A1I.dwg DATE: 11/21/01 PROJECT NO.: A07 -652 1/4' : T_0' CO 1/4' : T -0' A A 1 A CI CI • • 0 ua L 1 EQ. B1 TO STRUGTURI; ABOVE B1 LL 4 -0" 8' -0" [I 1 .0 Let HALLWAY I 105 L EQ. REFLECTED CEILING PLAN SPRING CLIP • • • OFFICE EQ. I 102 B1 4' -o" l— EQ. =1R= SPRINKLE NOTES FIRE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE FIRE DEPARTMENT BUILDING DEPARTMENT, LANDLORD, AND TENANT FOR APPROVAL AND OBTAINING ALL NECESSARY PERMITS TO PERFORM ALL WORK. 2. FIRE SPRINKLER CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS WITH LANDLORD'S REPRESENTATIVE PRIOR TO INSTALLATION. 5. TENANT SPRINKLER CONTROL VALVE TO REMAIN OPEN AND IF PLACED ABOVE CEILING SIGN TO BE INSTALLED CLEARLY INDICATING LOCATION OF VALVE. INSTALL #12 GA. VERTICAL WIRE AT 4' -0" O.C. CONNECTED TO MAIN RUNNER AND STRUCTURE ABOVE. INSTALL AN APPROVED COMPRESSION POST FLUSH WITH TOP OF CEILING GRID AND STRUCTURE ABOVE. GROSS RUNNER (INTERMEDIATE DUTY) INSTALL #12 GA. WIRE CROSS BRACING IN EACH PLANE OF MAIN RUNNER AT 12' -O" O.G. AT 45 DEGREE ANGLES IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6'-O" FROM EACH WALL MAIN RUNNER (INTERMEDIATE DUTY) NOTE: I. INSTALL AS REQUIRED UNDER 2006 IBC SECTION 2506.2.1 EG r I L SUSPENDED CEILING SUPPORT DETAIL /I 0 / 5' -5" A A w It T. Al 1 Al I\%1 .L' _L . I cv I P _L _ 4M111 _L 4 Al [ Al I I T 7 /I T T T / I I I I I N I I I L _ L ._L --- , 1 ._L J _L T O ` � 4. TRACK LIGHTS AT THE END OF FIXTURES TO BE CENTERED ON FIXTURES. MOUNTING HEIGHT FOR "A" FIXTURES gi 5' -6" TO q' -O" CLG. SHALL BE IS BELOW CLG TO TOP OF FIXTURE. 10. CEILING AREAS EXCEEDING 1,000 SF SHALL HAVE HORIZONTAL RESTRAINTS (DIAGONAL SPLAY WIRES OR RIGID BRACES) NOTE: CISCA REQUIRES BRACING FOR AREAS EXCEEDING 144 SF. 48' —O" Al I Al OEN__ AL NOTES I. LIGHT FIXTURES TO BE CENTERED EXACTLY BETWEEN SHOE FIXTURES. CONTRACTOR 15 TO INDICATE ON THE FLOOR THE PRECISE FIXTURE LAYOUT PRIOR TO INSTALLATION OF THE LIGHTS TO INSURE PROSPER ALIGNMENT. 2. PROVIDE ACCESS PANELS FOR SIGN INSTALLATION AND MAINTENANCE (AS REQ'D) VERIFY EXACT LOCATION QUANTITY WITH SIGN MANUFACTURER AND /OR P55 PROJECT MANAGER. 3. SUPPORT WIRES FOR LAY -IN CEILING GRID MUST NOT BE CONNECTED TO ANY LANDLORD MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT. 5. MOUNTING HEIGHT FOR "A" FIXTURES @ 11' -O" TO 10' -6" CLG. SHALL BE 24" BELOW GLG. TO TOP OF FIXTURE 6. MOUNTING HEIGHT FOR "A" FIXTURES @ 10' -6" TO 4 -6" GI-G. SHALL BE 20" BELOW GLG TO TOP OF FIXTURE S. PROVIDE EMERGENCY ILLUMINATION THROUGHOUT THE EXIT PATH. EMERGENCY ILLUMINATION MUST PROVIDE AT LEAST ONE -FOOT CANDLE AT TI-IE FLOOR LEVEL. I. WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL NOT BE LESS THAN 2- INGHES. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 3/4" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE. II. CEILINGS MUST BE DIVIDED INTO AREAS NOT EXCEEDING 2500 5F BY SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITIONS PENETRATING THE CEILING. THIS GAN BE WAIVED IF AN ENGINEERED STRUCTURAL ANALYSIS OF THE CEILING SYSTEM 15 PROVIDED DEMONSTRATING THAT THE CEILING SYSTEM PENETRATIONS AND CLOSURES ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACGOMODATE THE ADDITIONAL MOVEMENT. 12. SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVER -SIZE RING, SLEEVE, OR ADAPTOR THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST I" IN ALL HORIZONTAL DIRECTIONS. 15. FOLLOWING THE INSTALLATION OF THE CEILING GRID, BUT PRIOR TO INSTALLING THE PANELS, THE PROJECT MANAGER WILL INSPECT THE GRID'S CONSTRUCTION AND VERIFY THAT IT 15 SAFE TO INSTALL PANELS. %' Q II T 45' 0" 52' -O" I Al Al T Al Al Al EQ. 12' -0" EQ. SALES 101 Fin 5 10'-0" L EQ. i 0 V r II 1 11 zva Al B B1 A K EQ. LESENE7 II 1 1 1 T 0 0 C V I6' -0" IL — L_ q'4" • I T I2' -O" EQ. 0 c, EQ. I '-4" 6 T RECESSED FLUORESCENT LIGHT FIXTURES (SEE ELECTRICAL SHEET E -2) ()T-4.8 4' LINEAR FLUORESCENT FIXTURE (SEE ELECTRICAL SHEET E -2) 4' FLUORESCENT LIGHT FIXTURES (SEE ELECTRICAL SHEET E -2) 5' FLUORESCENT LIGHT FIXTURES (SEE ELECTRICAL SHEET E -2) 4' OFFICE STRIP LIGHT, MOUNT AT II' -O" A.F.F WHERE NO CEILING 15 PROVIDED. (SEE ELECTRICAL SHEET E -2) 5' OFFICE STRIP LIGHT, MOUNT AT II' -O" A.F.F. WHERE NO CEILING 15 PROVIDED. (SEE ELECTRICAL SHEET E -2) TRACK LIGHTING (SEE ELECTRICAL SHEET E -2) MONOPOINT COMPACT FLUORESCENT TRACK ( SEE ELECTRICAL SHEET E -2) ILLUMINATED EXIT LIGHTS (SEE ELECTRICAL SHEET E -2) EMERGENCY EGRESS LIGHTS (SEE ELECTRICAL SHEET E -2) SUPPLY AIR (SEE MECHANICAL SHEET MP -I) RETURN AIR (SEE MECHANICAL SHEET MP -I) LIGHT/FAN RECENED NOV 2 9 2007 PERMIT CENTEFs Project North R e v i s i o n s Date 11/21/01 Descr1ptfon OWNER REVISION • FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRNE SUITE 300 IORKIAND, WA 98033 P:425.827.2100 F:425.828.6899 TN�MAS 1F¢f SPA DER l S EON STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA REFLECTED CEILING PLAN DRAWN BY: GP DRAWING NAME: 01652A2.dwg DATE: I (/21/01 PROJECT NO.: A01 -652 QVFRSSQN STRUT S=ULE NOMINAL SIZE (INCHES) MAX. LENGTH (FT. 1/2 2 5/4 4 I S 11/4 10 1 1/2 12 2" IS ELTEt7 PLAN NOT'S I 2')(4' A.G.T. CEILING (CF -I) @ II' -0" A.F.F. (SEE DETAIL I /A2) GYP. BD. CEILING @ 16' -6" A.F.F. FAINT (P -I) 2 5 ALIGN FRONT OF LIGHT FIXTURE WITH FIXTURE RUN. 4 GYP. BD. CEILING a 8' —O" A.F.F. PAINT (P -I) 5 LIGHT FIXTURES TO ALIGN WITH ADJACENT LIGHT FIXTURE RUN 6 4 -1/S" BULKHEAD @ 1o' -11 A.F.F. PAINT (P -I) 1/4' : T_0' CO 1/4' : T -0' A A 1 A CI CI • • 0 ua L 1 EQ. B1 TO STRUGTURI; ABOVE B1 LL 4 -0" 8' -0" [I 1 .0 Let HALLWAY I 105 L EQ. REFLECTED CEILING PLAN SPRING CLIP • • • OFFICE EQ. I 102 B1 4' -o" l— EQ. =1R= SPRINKLE NOTES FIRE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE FIRE DEPARTMENT BUILDING DEPARTMENT, LANDLORD, AND TENANT FOR APPROVAL AND OBTAINING ALL NECESSARY PERMITS TO PERFORM ALL WORK. 2. FIRE SPRINKLER CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS WITH LANDLORD'S REPRESENTATIVE PRIOR TO INSTALLATION. 5. TENANT SPRINKLER CONTROL VALVE TO REMAIN OPEN AND IF PLACED ABOVE CEILING SIGN TO BE INSTALLED CLEARLY INDICATING LOCATION OF VALVE. INSTALL #12 GA. VERTICAL WIRE AT 4' -0" O.C. CONNECTED TO MAIN RUNNER AND STRUCTURE ABOVE. INSTALL AN APPROVED COMPRESSION POST FLUSH WITH TOP OF CEILING GRID AND STRUCTURE ABOVE. GROSS RUNNER (INTERMEDIATE DUTY) INSTALL #12 GA. WIRE CROSS BRACING IN EACH PLANE OF MAIN RUNNER AT 12' -O" O.G. AT 45 DEGREE ANGLES IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6'-O" FROM EACH WALL MAIN RUNNER (INTERMEDIATE DUTY) NOTE: I. INSTALL AS REQUIRED UNDER 2006 IBC SECTION 2506.2.1 EG r I L SUSPENDED CEILING SUPPORT DETAIL /I 0 / 5' -5" A A w It T. Al 1 Al I\%1 .L' _L . I cv I P _L _ 4M111 _L 4 Al [ Al I I T 7 /I T T T / I I I I I N I I I L _ L ._L --- , 1 ._L J _L T O ` � 4. TRACK LIGHTS AT THE END OF FIXTURES TO BE CENTERED ON FIXTURES. MOUNTING HEIGHT FOR "A" FIXTURES gi 5' -6" TO q' -O" CLG. SHALL BE IS BELOW CLG TO TOP OF FIXTURE. 10. CEILING AREAS EXCEEDING 1,000 SF SHALL HAVE HORIZONTAL RESTRAINTS (DIAGONAL SPLAY WIRES OR RIGID BRACES) NOTE: CISCA REQUIRES BRACING FOR AREAS EXCEEDING 144 SF. 48' —O" Al I Al OEN__ AL NOTES I. LIGHT FIXTURES TO BE CENTERED EXACTLY BETWEEN SHOE FIXTURES. CONTRACTOR 15 TO INDICATE ON THE FLOOR THE PRECISE FIXTURE LAYOUT PRIOR TO INSTALLATION OF THE LIGHTS TO INSURE PROSPER ALIGNMENT. 2. PROVIDE ACCESS PANELS FOR SIGN INSTALLATION AND MAINTENANCE (AS REQ'D) VERIFY EXACT LOCATION QUANTITY WITH SIGN MANUFACTURER AND /OR P55 PROJECT MANAGER. 3. SUPPORT WIRES FOR LAY -IN CEILING GRID MUST NOT BE CONNECTED TO ANY LANDLORD MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT. 5. MOUNTING HEIGHT FOR "A" FIXTURES @ 11' -O" TO 10' -6" CLG. SHALL BE 24" BELOW GLG. TO TOP OF FIXTURE 6. MOUNTING HEIGHT FOR "A" FIXTURES @ 10' -6" TO 4 -6" GI-G. SHALL BE 20" BELOW GLG TO TOP OF FIXTURE S. PROVIDE EMERGENCY ILLUMINATION THROUGHOUT THE EXIT PATH. EMERGENCY ILLUMINATION MUST PROVIDE AT LEAST ONE -FOOT CANDLE AT TI-IE FLOOR LEVEL. I. WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL NOT BE LESS THAN 2- INGHES. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 3/4" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE. II. CEILINGS MUST BE DIVIDED INTO AREAS NOT EXCEEDING 2500 5F BY SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITIONS PENETRATING THE CEILING. THIS GAN BE WAIVED IF AN ENGINEERED STRUCTURAL ANALYSIS OF THE CEILING SYSTEM 15 PROVIDED DEMONSTRATING THAT THE CEILING SYSTEM PENETRATIONS AND CLOSURES ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACGOMODATE THE ADDITIONAL MOVEMENT. 12. SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVER -SIZE RING, SLEEVE, OR ADAPTOR THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST I" IN ALL HORIZONTAL DIRECTIONS. 15. FOLLOWING THE INSTALLATION OF THE CEILING GRID, BUT PRIOR TO INSTALLING THE PANELS, THE PROJECT MANAGER WILL INSPECT THE GRID'S CONSTRUCTION AND VERIFY THAT IT 15 SAFE TO INSTALL PANELS. %' Q II T 45' 0" 52' -O" I Al Al T Al Al Al EQ. 12' -0" EQ. SALES 101 Fin 5 10'-0" L EQ. i 0 V r II 1 11 zva Al B B1 A K EQ. LESENE7 II 1 1 1 T 0 0 C V I6' -0" IL — L_ q'4" • I T I2' -O" EQ. 0 c, EQ. I '-4" 6 T RECESSED FLUORESCENT LIGHT FIXTURES (SEE ELECTRICAL SHEET E -2) ()T-4.8 4' LINEAR FLUORESCENT FIXTURE (SEE ELECTRICAL SHEET E -2) 4' FLUORESCENT LIGHT FIXTURES (SEE ELECTRICAL SHEET E -2) 5' FLUORESCENT LIGHT FIXTURES (SEE ELECTRICAL SHEET E -2) 4' OFFICE STRIP LIGHT, MOUNT AT II' -O" A.F.F WHERE NO CEILING 15 PROVIDED. (SEE ELECTRICAL SHEET E -2) 5' OFFICE STRIP LIGHT, MOUNT AT II' -O" A.F.F. WHERE NO CEILING 15 PROVIDED. (SEE ELECTRICAL SHEET E -2) TRACK LIGHTING (SEE ELECTRICAL SHEET E -2) MONOPOINT COMPACT FLUORESCENT TRACK ( SEE ELECTRICAL SHEET E -2) ILLUMINATED EXIT LIGHTS (SEE ELECTRICAL SHEET E -2) EMERGENCY EGRESS LIGHTS (SEE ELECTRICAL SHEET E -2) SUPPLY AIR (SEE MECHANICAL SHEET MP -I) RETURN AIR (SEE MECHANICAL SHEET MP -I) LIGHT/FAN RECENED NOV 2 9 2007 PERMIT CENTEFs Project North R e v i s i o n s Date 11/21/01 Descr1ptfon OWNER REVISION • FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRNE SUITE 300 IORKIAND, WA 98033 P:425.827.2100 F:425.828.6899 TN�MAS 1F¢f SPA DER l S EON STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA REFLECTED CEILING PLAN DRAWN BY: GP DRAWING NAME: 01652A2.dwg DATE: I (/21/01 PROJECT NO.: A01 -652 SCALE: 1/4' :T -0' 1' SCALE: 1/4 "_-0" MEI ==.1. 0 -".J. ∎ ∎ ∎ ∎1∎.. -M MIN I NORTH (FRONT) ELEVATION SOUTH (REAR) ELEVATION SW ES URCE 3 3 I I I I I I L J �� � 4 � I I I EVATII::N K ¥NOTES CIRCLES BUILDING FASCIA COPY #6500 WHITE NEON 10 M/M SILVA -TRIM _ RETAINER ALUMINUM SIGN CASE PAYLESS SHOESOURGE SIGN, ELEC. CONTRACTOR TO PROVIDE ELECTRICAL CONNECTION REFER TO SIGN MANUFACTURER'S SHOP DWG. FOR ADDITIONAL INFORMATION. EXISTING S' -O ", 1/2" GLASS STOREFRONT DOORS WITH CLEAR GLASS TRANSOM ABOVE LEASE LINE EXISTING ALUMINUM AND GLASS STOREFRONT EXISTING HOLLOW METAL DOOR AND FRAME WOOD CONSTRUCTION SECURE LETTER W/ — WOOD SCREWS OPEN CHANNEL LETTER, ALUMINUM SIGN CASE DRYWALL SECURE LETTER 1N/TOGGLE BOLTS SCALE: NO SCALE SILVA -TRIM RETAINER MASONRY SECURE LETTER 1N/LAG SCREWS $ EXPANSION SHIELDS SIGN MOUNTING METHODS INDIVIDUAL LETTERS - NOTE: INSULATION GLASS INSIDE CONDUIT TRANSFORMER BOXES FURNISHED BY TENANT SIGN COMPANY, LOCATION MAY VARY M OE SlitU OE BUILDING FASCIA PLEXIGLASS BACKGROUND ' SHALL BE 3" WIDER THAN THE OUTLINE OF EACH LETTER. FASTEN TO BACK- SIDE OF SIGN. COPY #6500 WHITE NEON 10 M/M SILVA -TRIM - RETAINER PLEXIGLA55 BACKGROUND ALUMINUM SHALL BE 3" WIDER THAN SIGN CASE THE OUTLINE OP EACH LETTER. FASTEN TO BACK- SIDE OF SIGN. SIGN NO NOTES I. ALL SIGNING TO BE PROVIDED AND INSTALED BY PAYLESS SHOESOURGE, THROUGH ITS SUPPLIERS. 2. SIGN FABRICATOR SHALL AFFIX UNION LABEL TO SIGN CASE, WHERE APPLICABLE. ALL ELECTRICAL WIRING IN SIGN CASE TO SPECIFICATIONS OF UNDERWRITERS LABORATORIES AND SEAL AFFIXED. 4. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE LOCAL GODES AND ORDINANCES. 5. SEE WRITTEN SPECIFICATION SHEET G -17, SECTION 16010 FOR INSTALLATION WIRING DETAILS. 516N FABRICATOR SHALL PROVIDE ALL FLUORESCENT OR NEON TUBES REQUIRED TO PROVIDE MAXIMUM BRIGHTNESS. THIS DRAWING PROVIDED FOR LAYOUT, PLACEMENT AND SCALE ONLY. DO NOT REPRODUCE LOGOTYPE GRAPHICS FROM THIS DRAWING. USE ONLY MASTER ART FOR SIGNAGE APPLICATIONS PREPARED BY LIPPINCOTT AND MARGULIES, NEW YOUR, NY, DATED JULY NOTE: ALL SIGN RETURNS SHALL BE BLACK REGARDLESS OF THE SIGN FASCIA COLOR SIGN CONTRACTOR TO OBTAIN A SEPARATE SIGN PERMIT. SIGN MANUFACTURER TO SUBMIT SIGN SHOP DRAWINGS TO ALL APPROPRIATE AGENCIES. SIGN MANUFACTURER TO SUPPLY INSURANCE CERTIFICATE TO MALL OPERATING MANAGER PRIOR TO SIGN INSTALLATION. NOTE: SIGN TO 5E VERI'IE SIGN MANUFA 'TURER SIN SHQF DRAM NGS TO BE SUBMITTED UNDER SEPARATE OVER R NOV 2 9 2007 PERMF CENTER, CONTINUOUS 5/M RACEWAY (BY TENANT SIGN CO.) PNT. TO MATCH BLDG. PRIMARY ELECT. SERVICE (BY OTHERS) - 2 "x2" GA.ANGLE CLIPS LOCATE FOR NON - VISIBILITY ( (BY TENANTS INSTA4L 3/8" Cp MTG BOLTS Project North R e v i s i o n s Date I (/27/07 Description OWNER REVISION 1 1 FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRKIAND, WA 98033 P:425.8272100 F :425.828.6899 STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA EXTERIOR ELEVATIONS AND SIGN DETAILS DRAWN BY: GP DRAWING NAME: o7652A5.dwg DATE: 11/27/07 PROJECT NO.: A01 -652 1 MI MEI I I. I II III \ i SCALE: 1/4' :T -0' 1' SCALE: 1/4 "_-0" MEI ==.1. 0 -".J. ∎ ∎ ∎ ∎1∎.. -M MIN I NORTH (FRONT) ELEVATION SOUTH (REAR) ELEVATION SW ES URCE 3 3 I I I I I I L J �� � 4 � I I I EVATII::N K ¥NOTES CIRCLES BUILDING FASCIA COPY #6500 WHITE NEON 10 M/M SILVA -TRIM _ RETAINER ALUMINUM SIGN CASE PAYLESS SHOESOURGE SIGN, ELEC. CONTRACTOR TO PROVIDE ELECTRICAL CONNECTION REFER TO SIGN MANUFACTURER'S SHOP DWG. FOR ADDITIONAL INFORMATION. EXISTING S' -O ", 1/2" GLASS STOREFRONT DOORS WITH CLEAR GLASS TRANSOM ABOVE LEASE LINE EXISTING ALUMINUM AND GLASS STOREFRONT EXISTING HOLLOW METAL DOOR AND FRAME WOOD CONSTRUCTION SECURE LETTER W/ — WOOD SCREWS OPEN CHANNEL LETTER, ALUMINUM SIGN CASE DRYWALL SECURE LETTER 1N/TOGGLE BOLTS SCALE: NO SCALE SILVA -TRIM RETAINER MASONRY SECURE LETTER 1N/LAG SCREWS $ EXPANSION SHIELDS SIGN MOUNTING METHODS INDIVIDUAL LETTERS - NOTE: INSULATION GLASS INSIDE CONDUIT TRANSFORMER BOXES FURNISHED BY TENANT SIGN COMPANY, LOCATION MAY VARY M OE SlitU OE BUILDING FASCIA PLEXIGLASS BACKGROUND ' SHALL BE 3" WIDER THAN THE OUTLINE OF EACH LETTER. FASTEN TO BACK- SIDE OF SIGN. COPY #6500 WHITE NEON 10 M/M SILVA -TRIM - RETAINER PLEXIGLA55 BACKGROUND ALUMINUM SHALL BE 3" WIDER THAN SIGN CASE THE OUTLINE OP EACH LETTER. FASTEN TO BACK- SIDE OF SIGN. SIGN NO NOTES I. ALL SIGNING TO BE PROVIDED AND INSTALED BY PAYLESS SHOESOURGE, THROUGH ITS SUPPLIERS. 2. SIGN FABRICATOR SHALL AFFIX UNION LABEL TO SIGN CASE, WHERE APPLICABLE. ALL ELECTRICAL WIRING IN SIGN CASE TO SPECIFICATIONS OF UNDERWRITERS LABORATORIES AND SEAL AFFIXED. 4. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE LOCAL GODES AND ORDINANCES. 5. SEE WRITTEN SPECIFICATION SHEET G -17, SECTION 16010 FOR INSTALLATION WIRING DETAILS. 516N FABRICATOR SHALL PROVIDE ALL FLUORESCENT OR NEON TUBES REQUIRED TO PROVIDE MAXIMUM BRIGHTNESS. THIS DRAWING PROVIDED FOR LAYOUT, PLACEMENT AND SCALE ONLY. DO NOT REPRODUCE LOGOTYPE GRAPHICS FROM THIS DRAWING. USE ONLY MASTER ART FOR SIGNAGE APPLICATIONS PREPARED BY LIPPINCOTT AND MARGULIES, NEW YOUR, NY, DATED JULY NOTE: ALL SIGN RETURNS SHALL BE BLACK REGARDLESS OF THE SIGN FASCIA COLOR SIGN CONTRACTOR TO OBTAIN A SEPARATE SIGN PERMIT. SIGN MANUFACTURER TO SUBMIT SIGN SHOP DRAWINGS TO ALL APPROPRIATE AGENCIES. SIGN MANUFACTURER TO SUPPLY INSURANCE CERTIFICATE TO MALL OPERATING MANAGER PRIOR TO SIGN INSTALLATION. NOTE: SIGN TO 5E VERI'IE SIGN MANUFA 'TURER SIN SHQF DRAM NGS TO BE SUBMITTED UNDER SEPARATE OVER R NOV 2 9 2007 PERMF CENTER, CONTINUOUS 5/M RACEWAY (BY TENANT SIGN CO.) PNT. TO MATCH BLDG. PRIMARY ELECT. SERVICE (BY OTHERS) - 2 "x2" GA.ANGLE CLIPS LOCATE FOR NON - VISIBILITY ( (BY TENANTS INSTA4L 3/8" Cp MTG BOLTS Project North R e v i s i o n s Date I (/27/07 Description OWNER REVISION 1 1 FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRKIAND, WA 98033 P:425.8272100 F :425.828.6899 STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA EXTERIOR ELEVATIONS AND SIGN DETAILS DRAWN BY: GP DRAWING NAME: o7652A5.dwg DATE: 11/27/07 PROJECT NO.: A01 -652 23 El 14 SALES SCALE: 1/4 " =1' -0" �C HALLWAY / SALES SCALE: 1/4 " :1' -0" SCALE: 1/4 ",1' -O" r 3" 23 23 24 SALES / HALLWAY Iq m C SALES SCALE: 1/4 " =1' -O" m 14 II \ O m 14 23 0 14 22 22 22 22 23 O� 9 RECt NOV z 9 ZUU7 PERMIT CENTEi- f NATION NOTES X 2 1 3 4 6 1 a I x 4 WHIM PINE NAILER, PAINT TO MATCH ADJACENT SURFACE. I X 2 WHITE PINE NAILER, PAINT TO MATCH ADJACENT SURFACE. I X 10 WHITE PINE NAILER, PAINT TO MATCH ADJACENT SURFACE. PHONE BOARD (SEE ELEC. DINGS. FOR MORE INFORMATION) H.M. DOOR IN H.M. FRAME - PAINT (P -I) BOTH SIDES. PROVIDE - QTY. 3 BOSTON RUBBER BUMPER, SERIES 40, COLOR: IVORY, SIZE: 55" O.A. LENGTH, G.G. TO INSTALL PER ELEVATION INCLUDE: RUBBER COIL @ 21 ", ALUMINUM CHANNEL © 30 1/2" $ 6 END CAPS PER DOOR. MODIFY BUMPER SIZE ACCORDING TO DOOR SIZE. IF OTHER THAN 3' X T DOOR, VERIFY IN/ PM. BUMPER PRODUCTS TO BE PROVIDED BY P55 RE PURCHASING. PROVIDE TRIM PROTECTOR BAR. PAINT (P -I) 1I -O" H. X I' -6" W. PREFABRICATED CORNER BOX PROVIDED BY P55. INSTALLED BY G.G. FIRE EXTINGUISHER PAINT (P -2) LOCKERS $ COAT RACK PROVIDED BY P55, INSTALLED BY G.G. I I 12 F 13 14 IS 16 17 F IS 1 IQ 20 22 23 24 GRAPHIC PROVIDED BY P55, INSTALLED BY G.G. PAINT (P -IE) TOP, BOTTOM, SIDES, AND BEHIND POSTE'R MOP SINK PER SPECIFICATIONS. FIN END PANEL PROVIDED BY P55, INSTALLED BY G.G. PREFABRICATED WING WALL PROVIDED BY P55, INSTALLED BY G.G. H.M. DOOR IN H.M. FRAME - PAINT (P -I) BOTH SIDES. ELECTRICAL PANEL (SEE ELEC. DINGS. FOR MORE INFORMATION) EXISTING H.M. DOOR IN H.M. FRAME - PAINT (P -I) TENANT SIDE ONLY EXISTING CLEAR TEMPERED GLASS STOREFRONT DESK, FILE, AND COMPUTER TABLE PROVIDED BY P55, INSTALLED BY G.G. EXISTING CLEAR TEMPERED GLASS ENTRY DOOR SLATWALL PANEL PROVIDED BY P55, INSTALLED BY G.C. 4" RUBBER COVE BASE (RB -I) DRINKING FOUNTAIN. 5EE PLUMBING DRAWINGS. Project North R e v i s i o n s Date I I/27/01 A3,1 Description OWNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRNE SUITE 300 10R1GAND, WA 98033 P:425.8272100 F:425.828.6899 REGIS i ERED ARCHITECT • SPADER ASilINGTON N_7812 j r • THOMAS STATE OF y STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA EXTERIOR ELEVATIONS INTERIOR ELEVATIONS DRAWN BY: GP DRAWING NAME: 07652A31.dwg DATE: I I/21/07 PROJECT NO.: A07 -652 4 A 0 N 23 OFFICE SCALE: 1/4 ".1' -0" SCALE: 1/4 " :1' -0" 16 23 A 23 25 OFFICE / HALLWAY I-f 23 13 SCALE: 1/4 " =1 " -0" 00 25 O� 25 2 3 HALLWAY / OFFICE C C A 25 4 o c OFFICE SCALE: 1/4 " :1' -O" 25 N _ -. :Q T--: -,` to il ^ Z0 n n 25 SEE SHEET A3.I FOR INTERIOR ELEVATION KEYNOTES E1a ���Ih +e R Nov 2 9 ZOU7 PERMIT CEN 1 E Project North Revisions 0 0 MEM • • • Date 1 1/21/01 Description GINNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRXLAND, WA 98033 P:425.827.2100 F:425.828.6899 STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA INTERIOR ELEVATIONS A e2 DRAWN BY: GP DRAWING NAME: 01652AS2.dwg DATE: I (/21/01 PROJECT NO.: A01 -652 SCALE: 3" = 1' -0'• HEAD %" N f. VARIES, SEE PLAN —1N JAMB SEE PLAN 2" INTERIOR ] OOR 1 RA GYPSUM BOARD . / SEE ELEVATIONS FOR FINISHES r• METAL TRACK, SAME GUAGE AS PARTITION V 2 HOLLOW METAL FRAME W/ STOP HOLLOW METAL FRAME W/ STOP (3) ANCHORS PER JAMB (2) METAL STUDS, TYP EACH SIDE OF FRAME 5 /s" GYPSUM BOARD SEE ELEVATIONS FOR FINISHES DETAILS CARPET SCALE: I" = I" SUBSTRATE 6 JOHNSONITE CE-XX -AA (COLOR TO BE SELECTED BY OWNER) LUXURY VINYL TILE, PER PLAN JOHNSONITE TRACK BASE MT -00 -A, ALUMINUM, 1/4" LEG - NAN5ITION 1:7= CiARF�T TO Q.Y.T. PER PLAN SCALE: I" = I' -O" 1 31mnmm r d BULG OETAL 7 -------------------- ---- ATTACH METAL FRAMING TO ROOF JOISTS. 5 /s" GYPSUM BOARD. METAL TRIM, FLOAT 4 TAPE. -%" 206A METAL STUDS. LAY -IN ACCOUSTIGAL CEILING @ II' -O "AFF SOFFIT PAINT VARIES, SEE SHEET A2. 5 /6" GYPSUM BOARD. METAL TRIM, FLOAT 4 TAPE. TN(F'ICAL SCALE: 3" = I' -O" 0 TYF I G AL FLAN AND ELEVATION CLEARAN z ( -11" MINIMUM x Iq" MAXIMUM in I I I MUM 0 FONT WAT'6i GLOAT GL RANCIM &RAE 5AR DETAILS F.R.T. WOOD ANCHORING BLOCKING, CONTINUOUSLY SECURE TO METAL STUDS. SIZE AS REQUIRED TOGGLE BOLT. 48" MINIMUM 56" MINIMUM 0 m 1/2" 6RAB BAR VERTICAL 56GTION I da m 8" MIN. KNEE CLEARANC MIN. L4VAYDRY CLEARANCES 12" MAX. A TOILET 4 �1 'Ii I cn I 34 " -41" 36" MAX. MIRROR r 42" MIN. smE wn se car cllhzurcg 11/2" DIAMETER GRAB BAR. METAL WALL FLANGE. X00 V 11" INSULATED PIPES 6" MINIMUM OE CLEARANCE 1 m F.R.T. WOOD ANCHORING BLOCKING, CONTINUOUSLY SECURE TO METAL STUDS. SIZE AS REQUIRED TOGGLE BOLT. 3�TA1LS I. ALL TOILET ROOM FIXTURES AND CONSTRUCTION MUST COMPLY WITH LOCAL STATE BUILDING CODES, LOCAL $ STATE LAWS, AND I1g2 ANSI ACCESSIBILITY GUIDE LINES. 2. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORGE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF (22.2 N). FAUCETS SHALL COMPLY WITH 4.21.4. LEVER - OPERATED, PUSH -TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS, IF SELF - CLOSING VALVES ARE USED THE FAUCET SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. S. FLUSH CONTROLS TO BE MOUNTED ON WIDE SIDE OF TOILET AREA. (LONG LEAD ITEM WHEN ON RIGHT HAND SIDE) i i ., I �� ► 1 METAL WALL FLANGE. 1 1/2" DIAMETER GRAB BAR. INSTALLATION MUST SUPPORT 300 LBS. DOWNWARD PULL. JOHNSONITE BENDABLE TRACK MT -00-A, ALUMINUM I/2" LEG LUXURY VINYL TILE, RUN PER FLOORING PLAN. A -4 0 SCALE: AS NOTED 31_0:: L 3: -0 FLAN VI EW (DOUBLE POOR) SCALE: 3/8" = I' -O" NOTE: DO NOT NOTCH OR GUT MATS FOR PLACEMENT OF COLUMNS OR SECURITY DEVICES. IF SITUATION ARISES, SHIFT MAT BACK FROM STOREFRONT AND USE AN EXTENDED THRESHOLD. A SECOND ALTERNATIVE IS TO SHIFT THE MAT BACK CLEAR OF OBSTRUCTION AND CONTINUE PSS TILE IN THE VOID AREA. OBTAIN PS5 CONSTRUCTION MANAGER OR P55 ARCHITECTURAL PROJECT MANAGER APPROVAL FOR MAKING CHANGE. ENT vAT DETAILS .a IIIIIIIMI w.w.w.w.wA A I Ar Ar A r :rAwmow. Iw.w.w.w.w, Aw.w.w.w.w.►� Ar Air w.w.w.w.w.• A JOHNSONITE VI L MOULDING CD -40 (BLACK) SLACK EDGE VINYL TRANSITION STRIF' DETAIL AT GIRGLE SCALE: FULL 11 • SECURITY SYSTEM FASTENED THRU FLOORING (IFREO'D.) MITER CUT AT CORNERS CARPET STRIP MODEL TL3T5RM EXTRUDED ALUM. RAIL STORE SCALE AS SHOWN v SINGLE LAYER OF I /S" VGT, FLOAT VGT, BEVEL EDGE Do/4m RUN WIRE TO SECURITY SYSTEM IN CONDUIT AS SHOWN ON TELEPHONE SHEET GLASS STOREFRONT CONC. SLAB RONT ENTRY t7ETA I L I ' 1 5/8" TYPE 'X' GM (BOTH SIDES) TO 6" A.F.G. ON 5 5/8" 20 GA. MTL. STUDS @ 16" O.G. TO UNDERSIDE OF DECK. PROVIDE DIAGONAL BRACING AS REQUIRED. A.C.T CEILING (CF -I) III-0" A.F.F. U NO CEILING, EXPOSED ROOF DECK t ' I Ix4 NAILER (WHITE PINE) PAINT TO MATCH ADJ. SURFACES a 10 Ix10 NAILER (WHITE PINE) PAINT TO MATCH ADJ. SURFACES Ix2 NAILER (WHITE PINE) FAINT TO MATCH ADJ. SURFACES 4" RUBBER COVE BASE 3 5/8" METAL BRACING @ 4' -O" O.G. BOTH SIDES ALTERNATING (BRACING REQUIRED IF PARTITION STUD LENGTH EXCEEDS 16' -O9 - USE (4) NO. 1/4 -14 SHEET METAL SCREWS AT EACH CONNECTION. - ALL METAL STUD MEMBERS TO BE 362 SJ 20 UNLESS NOTED OTHERWISE. , 1/5"4 POWDER ACTUATED FASTENERS (RAMSET) @ 2' - O.G. Ix8 NAILER (WHITE PINE) PAINT TO MATCH ADJ. SURFACES SECTION OCCURS AT SHELVING "E" REFER TO INTERIOR ELEVATIONS FOR NAILER LOCATIONS AT "A ", "5 ", "C" AND "D" NOTE: SEE DETAIL 2/A-4 FOR NAILER FASTENING PROCEDURES. WA,L S�GTION SCALE: 1/2" = I' -O" OFFICE 4 O (V 0 II 9- (n 0 10 0 ± 81 3/S" A.F.F. FASTEN POINT SALES AREA 7 1/2" A.F.F. FASTEN POINT WALEh 9•01 SCALES 3 -0 SCAM 3 -0' 2 � A -4 0 • WALL ELEVATION womfoicoms■amtwof METAL STUD WALL insisrimmom 1A10017 STUD WALL NAILER FASTENING PROCEDURE GONG. BLOCK WALLS NAILING STRIPS TO BE TOGGLE BOLTED AT 4' -0" O.G. DOUBLE NAILED AT 2' -0" WOOD STUD WALLS NA NAILING STRIPS TO BE DOUBLE NAILED AT EACH STUD W/ I2d COMMON NAILS METAL STUD WALLS SCALE: 3" = 1' -0" LER DETAILS METAL OR WOOD STUD BEYOND I X WOOD NAILER NAIL OR SCREW PLACEMENT NAILING STRIPS TO BE ATTACHED W/ SHEET METAL FASTENERS, NO TRIM SCREWS GYP. BD. (AS REGD.) METAL STUD PARTITION WALL (SPACING AS REQ'D) GYP. BD. (AS REQ'D) I X WOOD NAILER DOUBLE NO. 8 SHEET METAL SCREWS (MIN. 3" LENGTH - COUNTERSUNK) GYP. BD. (AS REQ'D.) WOOD STUD PARTITION WALL (SPACING AS REGD.) GYP. BD. (A5 REVD) I X WOOD NAILER 12d COMMON NAILS ( DOUBLE NAILED - 3 1/4" LENGTH) REIvi NOV 2 9 2007 PERMIT CENTEh Project North Revisions Date I1/21/01 Description OWNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE; SUITE 300 KIRKLAND, WA 98033 M25.827.2100 F:425.828.6899 REGISTERED ARCHITECT 1 THOMAS 0 SPADER rani OF WASHINGTON STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA SECTIONS /DETAILS DRAWN BY: GP DRAWING NAME: 01652A4.dwg DATE: 11/27/01 PROJECT NO.: A01 -652 Section 01005 PSS space:# ® New Construction plans Received ❑ Existing tenant Plans * ® LOD Received ▪ Tenant Criteria Received ess 4Pr, =:ii9N S H O E S O U R C E STANDARD C -1 SPECIFICATIONS TENANT IMPROVEMENTS Store Development ; 120 SE 6th St., STE 102; Topeka, KS 66603 -3515 785- 233 -5171 Fax: 785 - 270 -7880 Location:Southwest center NEC of Southcerrter Parkway & Minkler Blvd. Tukwila, WA. 98188 Landlord (LL):Wig Properties,LLS 4811 -134"` Place SE Bellevue, WA. Mall Mgr. Contact Same as above LL Tenant Coordinator:Same as above Mr. Mike Weflin Cell # 509 31 Work Scope Type: S/C Format: Hot Zone Ph II Decor : *8 Level A District: A1C Date: 11- 01-07 Store : 01723 New Store ❑ Relocation ❑ Remodel PSS Attorney: * Phone # PSS Rep: Cowan Phone #785 - 270 - 7802 PSS Project Manager Contact: Field Office #: 785 -270- 7842 Voice Mai17842 Tenant Furnished Items: Carpet Carpet/Tile Joiner, Safe(s), Display Panels, Shoe Fixtures, Security Lock(s), Lighting Package, Laminated Flooring and /or Porcelain /Ceramic Floor Tile and Accessories, Display FF & E, Signs, Prefabricated Fins /Corner Boxes, Lockers, Custom Carrier Thermostats and Sensors, Boston Bumpers and Entry Mats. Materials as required by design. ❑ Total Payable by Landlord: S Introduction: This format conforms to the 16 Division Construction Specifications Institute (CSI) System, except that references to Division 2 (Site Work), Division 4 (Masonry), and Division 5 Metals) ' dealing with the construction of improvements beyond the lease line of the premises, are omitted, it being understood that a material consideration of the Lease is that the Landlord has provided or will provide (i) adequate utilities to the lease line, dedicated solely for Tenant's use including limitation, electrical, natural gas, sanitary sewer, storm sewer, water, life safety control cable, and telephone; (iii) exterior walls and roof to the demised premises and; (iii) free and unobstructed ingress and egress from frreight and customer entrances to a public right -of -way and adequate location for trash dumpster, all prior to Tenant's possession or obligation to pay rent under terms of the L p ease. ❑ All utilities serving Tenant's demised premises shall be metered in accordance with Landlord's requirements. No references are made to Division 2 (Site Work), Division 4 (Masonry) Division 5 (Metals), Division 12 (Furnishings), g Division 13 Special Construction), and Division 14 (Conveying Systems), although special language may be added if work under any of these Divisions is required. 17 Payless Y q u�red. Divisi o n i s a ay ess added section For clarifications. Section 17000 is the last page of the C-1 specifications. As noted below, Landlord and Tenant's Contractor shall provide and install at its sole cost, all materials, equipment and appliances required to complete, in good and workmanlike order, all work described herein and shown on the drawings attached hereto and incorporated herein. Tenant shall install tenant's signs and trade fixtures at Tenant's expense unless otherwise noted. SEE ARCHITECTURAL DRAWING COVER SHEET FOR INDEX OF DOCUMENTS DLEASE EXHIBIT DOCUMENTS CONSIST OF FOLLOWS: ❑Exhibit * * *!* 01005a Components installed within the premises, whether existing or to be constructed, meet or will meet all current fire, health, safety and building PHII HZ 3 -6 -07 r8 PAGES AS Sign Company:Loren Building Exterior Color Unknown SDC Approved Signs: ❑ Store Front ❑ Raceways El Right Side ❑ Left Side ❑ Back side ❑ Under Canopy ❑ Ribbon on Pylon ❑ Pylon 0 Monument ❑ ❑ Window Graphics ❑ Barricade Graphics ❑ Sign criteria PSS Architect: Freiheit 7 ho Phone # 425- 827 -2100 Overall Width in ft28'.' Overall Depth in Ft.105' Total Leased Sq. 2959F1.S.F. P55 APM: JIB 785- 270 -7820 APM email ' "John Osier 785 - 270 - 7842 Johr+WO.sier @ pa wl ess. rmn 120 SE 6th: Ste. 102 T opeka, K5. 66603 Existing PSS Landlord DNA Contractor Contractor ❑ Z x Section 01005b The General Contractor shall provide a copy of these specifications and drawings to each subcontractor performing the work and shall provide 01005c the names, addresses, e-mail, and telephone numbers of each subcontractor to the Tenant. CONTRACTORS ARE RESPONSIBLE FOR DOWNLOADING THE CURRENT VERSION OF ADOBE ACROBAT READER FOR VIEWING AND PRINTING BID DOCUMENTS. General Contractor shall be responsible to demolish and remove from premises all existing improvements, fixtures, etc., except those that are to be incorporated in the scope of work defined herein. It is the 01005d responsibility of the contractor to immediately notify the Tenant's Project Manager, named above, when portions of the demolition would affect structural integrity, compliance with fire code(s), or when suspect hazardous materials (i.e., asbestos, PCB's, etc.) are encountered before proceeding with the related work. 01005e ❑°'°*x° interior floor space within the demised premises shall be at grade with the adjoining finished mall floor. ❑ * * ** All interior 01005f floor space within the demised premises shall be at grade with the adjoining sidewalk which shall be elevated by at least six (6) inches above the grade of the adjoining parking lot and rear pavement of the common improvements. This floor space shall be accessible to an ADA compatible "Path of Travel ". 01005g 01005h (remodels) WORK SCOPE DESCRIPTION codes of the city, county and state in which the premises are situated and all Federal Occupational Safety and Health Act guidelines (OSHA) and Americans with Disability Act (ADA). Prior to acceptance of the completed work, General Contractor shall provide a Certificate of Occupancy or equivalent issued by the governmental agency or agencies having jurisdiction and authority to issue same. Tenant shall take possession of the premises subject to the issuance of such certificate and satisfactory completion of all work specified herein. landlord for there work per the lease and payless ShoeSource Contractor per cotracted work. Upon Landlord's receipt of Tenant furnished items, but not later than the Lease commencement date, Landlord shall remit the total allowance set forth above to Tenant, if unpaid after thirty (30) days of commencement of Lease. Tenant shall add interest at the maximum lawful rate and offset its rent obligation until fully paid. For the existing store, the General Contractor shall review a Critical Path Method (CPM) Schedule with Store Manager at least one (1) week prior to remodel and on a daily basis so that once construction has commenced, manpower requirements can be scheduled in advance. This store will continue its normal operating hours. The Contractor will be responsible to clear the store of all construction material, reset fixtures, etc., EXCLUDING MERCHANDISE. Also clean and vacuum the store. All building and parking areas must be suitable for business operations, each morning prior to the normal opening hours. Do not use the store's vacuum or supplies. Equipment, tools and trash must be removed from the store prior to opening. 01005i Contractor shall commence work 1/2 hour after regularly scheduled (remodels) business hours and end no later than 1/2 hour prior to scheduled opening PHII HZ 3 - 06 - 07 r8 Existing PSS Landlord DNA Contractor Contractor ❑ ® ❑ n x ❑ ❑ ❑ El Z ❑ 17 Section WORK SCOPE DESCRIPTION time. Security, if applicable, to be coordinated by the District Manager with the Construction Project Manager. Cover Tenant's fixtures, register and merchandise with Visqueen (min. 4- mil Polyethylene sheeting) at all times. Do not reuse. Replace nightly 01005k Keep dust and debris off fixtures, merchandise and equipment. PSS may also require screen covering at storefront and /or area of transition between carpet and tile as a dust control method. 01005j Remove and reinstall fixtures in conjunction with flooring installation 010051 and /or wall painting. Fixtures should be reinstalled according to the fixture layout, which may deviate from the existing layout. 01005m 01005n 01010 Contractor must ensure a superintendent at the job site during work hours. Sub - contractors will not be allowed on the job site without full - time superintendent being present. AT ALL TIMES PER CONTRACT Upon arrival at the jobsite, Contractor's Superintendent is responsible for verifying all critical dimensions, including but not limited to width of store, depth, ceiling height, storefront and signband dimensions. Superintendent shall immediately contact Payless Project Manager to confirm. Contractor must a - ma /Ito Protect Manager & cc: the APM on as built digital photos as email attachments at the completion of the job. These photos shall be taken with at least a 3 Mega pixel auto focus camera and have a minimum resolution 0' 640 x 480 pixels with a total of at least 20 views of the project covering: Exterior store elevations with signs, interior store front area(s), cross & rear aisles views, office areas, and miscellaneous construction topics identified or requested by the project manager. * * ** Tenant will provide: ❑ carpet, ❑carpet /tile joiner, ©safe(s), shoe fixtures, ® display panels, rolling grille, ®lighting package,® flooring systems, and /or ❑ porcelain /ceramic floor tile and accessories, ® signs, ® pre - 01040 fabricated fins, corner boxes, and ©cashwrap, upon Contractor's notice not less than three (3) weeks prior to date required for installations, shipped freight prepaid to the consignee at an address designated by the General Contractor who accepts risk of loss prior to installation on the premises. Sound system supplied by Muzak. Any Tenant provided items that are NOT NEW shall be carefully inspected, cleaned, and touched up to LIKE NEW condition. Items discovered to be NOT ACCEPTABLE due to non - repairable damages, 01040a and /or color variations shall be brought to the Project Manager's attention as soon as possible so that replacements can be ordered. The Contractor is to insure that ALL installed items shall be clean and free of dirt, dust, old labels, packing tape, markings, etc. prior to the stocking of the store. Cost associated with fixture cleaning is to be noted in all bids. General Contractor shall be responsible to coordinate the work and 01041 access to the Tenant's space with the Mall Manager; Landlord's Tenant Coordinator, Landlord's General Contractor or other designated agent. PHII HZ 3 - 06 - 07 r8 Existing PSS Landlord DNA Contractor Contractor n 71 ❑ ❑ n ❑ ❑ Z ❑ ❑ Section WORK SCOPE DESCRIPTION Contractor collaboration with the following Payless specialty equipment 01041a installers is required on all projects: Muzak, ShopperTrak, Security Solutions, Sensormatic, Spencer Technologies and other vendors of Payless ShoeSource. Any changes deviations or alternatives to these specifications must be submitted in writing, prior to installation, to Tenant, for 01300 written approval. If drawings and specifications conflict, contractor must contact above named Project Manager for clarification. 01500 01530 01564 The Contractor shall be responsible for all costs including, but not limited to, permits, plan check fees, utility tap fees, MEA approval tags (NYC), temporary utilities including but not limited to gas, electricity, water and trash removal. Provide and install barricade(s) or enclosure(s) in accordance with Landlord's criteria. Coordinate with PM on installation and delivery of P55 special graphics on barricade. Vacant space, if any, adjacent to the demised premises, shall be secured 01530a with storefront, plywood, or door, front and rear, to prevent entry by unauthorized persons. Existing heating and air conditioning, electrical and plumbing systems 01535 serving the premises are warranted by the Landlord to be in good operating condition. Landlord agrees to hold Tenant free from any cost of repair or replacement of such existing components for a minimum period of one (1) year from the date of commencement of the Lease. All completed or adjacent work shall be protected, all rubbish, debris, and construction materials shall be removed at completion of work, and the premises delivered to the Tenant ready for installation of its' fixtures and merchandise cleaned as follows: a) glass and metal framing to be washed and polished. All labels, paint marks, excessive putty or silicon, etc., to be removed. b) Floors to be broom cleaned, vacuumed or dust mopped and scuff marks removed to owner's satisfaction just prior to punch list/merchandising. Carpet to be free of stains, dirt, etc. Clean per carpet sheet to remove stains and dirt. c) Hardware to be cleaned of dirt and protective coatings and polished. d) Wall and vertical surfaces dusted, wiped and cleaned free of stains and dirt. e) Ceramic floor tile and /or flooring systems cleaned per manufacturer's instructions. f) Mill work and fixtures to be cleaned, free of dust, and protective coatings removed. g) Restroom mirrors and fixtures washed; labels and marks removed and polished. h) Light fixtures, grills, and diffusers to be cleaned and free of dust. I) Payless leased or owned interior /exterior spaces without noted construction work shall be cleaned in accordance with the criteria above. When applicable as enumerated in Supplemental Agreement of the construction contract, prior to commencement of any Work, Contractor, through Contractor's Bonding Company, shall deliver 01740 a commitment to Payless for Payment and Performance Bond(s), in statutory form, for the full amount of the Contract Sum. Such Bond(s) shall name Payless as beneficiary and obligee and shall be issued by Contractor's Bonding Company. Payless shall make payment for Bond(s) directly to Contractor, which payment shall be included within the Contract Sum. DIVISION 3 -- CONCRETE FLOOR STRUCTURE ON GRADE PHII HZ 3 - - r$ Existing PSS Landlord DNA Contractor Contractor ❑ ® ❑ ❑ Section 03346 03346a 06001a 06001b 06200 07200 WORK SCOPE DESCRIPTION New floor structure shall be concrete; Portland cement, ASTM C 150, Type 1, and the applicable sections of the "Building Code Requirements for Reinforced Concrete" of the American Concrete Institute ACI -318- Latest Edition are included as a part of this specification. Working stress 03300 for all concrete shall be 3,000 P.S.I. at 28 days. Reinforcing mesh shall be Fibermesh fiber, by Fibermesh Company (423) 892 -7243 conforming to ASTM C -39, C -78, C -496. Slab under ceramic tile shall have a flatness /levelness of F /F All other slabs shall be F /F Existing floor structure shall be prepared to receive carpet or flooring systems by repairing depressions, cracks, joints and holes with Latex base floor stone, with all floor tile replaced, and existing floor tiles firmly bonded to the floor, which shall be dry and free of dirt and wax. Cracks in existing concrete floor to receive ceramic floor tile, to be epoxy patched prior to tile setting. If existing floor structure is other than concrete, submit for Tenant's approval prior to commencement of any construction. All existing slabs shall be corrected to achieve flatness /levelness per 03300. Under floor conduits, electrical and telephone outlets to register counter location by electrical contractor. Refer to floor plan and electrical drawings for appropriate location of raceway or conduits. Provide a self - leveling cementitious underlayment in accordance with the contract documents that shall be Ardex K -15 by ARDEX INC. Contact: Mike Wagner; 314-724-2756. Flatness and levelness shall be per 03300. Inst shall utilize manufacturer approved mixing tools, equipment, 03346b and methods. Underlayment shall be installed from a featheredge to any thickness in one pour. Underlayment shall develop a compressive strength of approximately 4100 -psi as per ASTM C -109 /mod. Installation and execution shall utilize Ardex primers, additives, and feather finish self- drying, cement - based, finishing underlayment skim coat /flash patch as project condition warrant and manufacturer's installation directions require. AS NEEDED DIVISION 6 -- WOOD AND PLASTICS Provide and install pine nailing strips at locations shown on interior 06001 elevations and floor plans. Nailing strips are load bearing and fastening procedure shall be followed precisely as shown on the drawings. Provide and apply fire retardant as required by local codes. Provide solid wood blocking in stud walls to receive handicapped grab bars in restroom. Provide solid wood blocking in stud walls to receive Sales Area fixtures as noted on plans. Display panels provided by tenant to be installed in accordance with contract documents and details shown on exhibits /drawings. DIVISION 7 -- THERMAL AND MOISTURE PROTECTION General Contractor to maintain minimum insulation values of R -11 in the wall assembly and R -19 in the roof /ceiling assembly, unless otherwise indicated or required by local energy codes. ALL ROOF INSULATION IS BY LANDLORD 07533 ® Roof penetrations, if required, shall be made by the Landlord's authorized Roofing Contractor, or in accordance with Landlord criteria. ALL ROOF WORK WILL BE DONE BY LANDLORD ROOFING COMPANY. PHII HZ 3 - 06 - 07 r8 Existing PSS Landlord DNA Contractor Contractor ❑ ® ❑ ❑ ❑ ❑ 0 El x Section 07533 (cont'd) WORK SCOPE DESCRIPTION ❑ ** **Whenever PSS or their contractors install a total roof system, they shall provide and install a complete single ply waterproof roofing system. Installation shall be by firm with minimum of three (3) years of experience in the installation of single ply roofing systems and shall be as approved by roofing system and materials manufacturer. Complete system shall be under one contract. Inspect roof substrate and verify in writing any deficiencies for remedial activity prior to installation of roofing. Provide temporary cover of the work and structure as required to prevent damage. Materials: Singly -ply membrane of a low shrink polyester fabric with thermo- plastic membrane by Duro -Last Roofing, Inc., 525 Morley Dr., Saginaw, MI 48601: Eric Day; 1- 800 - 248 -0280, Seal Dry 7000 is the only approved equal. All other systems will not be approved. Installation: Through continuous 3" securing tabs, factory dialectically welded at 4' -9" o.c. Mechanical fasteners distribution placed 12" o.c. through 3" securing tabs. Membrane and related items UL class A roof system. Oualifications; Roofer shall be approved by manufacturer. All components of roofing shall be approved in writing by manufacturer. The owner reserves the right to employ an independent inspection agency at his expense. Contractor shall have the roof inspected by manufacturer to ascertain that the roof system has been installed in accordance with manufacturer's specifications. Defective work shall be correct or replaced at no additional cost. Warranty; Provide fifteen (15) year warranty on workmanship. Corrective repairs shall be at contractor's expense. Warranty on manufacturer's materials shall be for fifteen (15) years. A written warranty must be submitted prior to final acceptance. No work shall be performed on roofing system without roofer and manufacturer's approval. Corrective repairs shall be made within seventy-two (72) hours of notification of contractor. Submittals: Written confirmation of roofer's qualifications shall be submitted along with literature on roofing membrane, sealants, sheet metal, shop drawings, PVC weldable drip edge, Gravel /water stop, termination bar, white breathable 2 -way vents and pourable sealer. Twelve (12) inch samples of gravel /water stop; drip edge and termination bar shall be submitted. Submittals to Manufacturer: Membrane shop drawings for approval, approved number of shop drawings by manufacturer returned to owner. Membrane: .035" thick sheets to 2,500 sq. ft., white thermoplastic alloy bonded to high tenacity, lo- shrink polyester fabric, resistant, to ultraviolet rays, micro - organisms and most caustic chemicals conforming to the following minimum physical properties: Flashing: Roof membrane .035 ". Termination Sealant: Fed. Spec. TT -C -598 and TT S - 00230C. DIVISION 8 -- DOORS, GLASS AND GLAZING, HARDWARE PHII HZ 3 - 06 - 07 r8 Existing P55 Landlord DNA Contractor Contractor Section 08111 08305 08330 08330a WORK SCOPE DESCRIPTION ❑ ' ° ° " *°i° Provide and install metal door and (grouted) frame (factory primed) at freight entrance shown on floor plan, 3' -6" x 7' -0" full flush hollow core 1 3/4" thick insulated core (polystyrene, urethane, etc.) and no less than 18 gauge cold rolled steel skin; 14 gauge frames with 14 gauge strike, 9 gauge hinge, and 12 gauge closer reinforcements, as manufactured by Steelcraft, Ceco, Fenestra, Curries, or Republic Steel, with security peephole. 4 1/2" x 4 1/2" BB butt hinges with NRP (non - removable pins) and hinge reinforced 61291 Marker CP. • `' .se Provide and install door closer Corbin - Russwin DC2200 x US26D. Provide and install one Schlage "5" Series (Saturn) #5170 x US26D half dummy. ® * Provide and install Pemko 305CR weather - stripping, Pemko #222 AV door bottom and Pemko 271A threshold. Ives 445/446 (when applicable) floor stop or Ives 402 1/2 (408 1/2) wall stop. ® "-a *x Paint exterior of door and frame to match exterior. All hardware to be U5260 finish. If door opens to interior corridor, insulation and weather - stripping may be omitted. ® *° - =- Access panel, if required, shall be CESCO; SR -1 drywall and plaster access panels or Glendon Fiberglass access panels. Hinge shall be concealed type, latch to be flush mounted, screwdriver operated cam, and the finish shall be "paint grip ". ❑ * * ** Tenant shall provide and install an upward coiling, electrically operated or manual grille, to match Kawneer Trifab #17(clear anodized) bottom bar and side guides, as manufactured by one of the following: ❑Metro Door or Mobilflex sliding grille (800- 501 -3531 fx: 813 - 248 -0900) flDynaflair (800- 254- 3539 fx: 813- 248 -0900) or approved equal. Door shall have "U- Change" cylinders on all security locks and key stations. U Change cylinders will be coordinated through Security Solutions and will be installed by local locksmith. The contractor shall coordinate complete installation of the grille with the Tenant and the installing contractor. The contractor shall provide all labor and material to frame and finish the soffit and other enclosures necessary to complete the storefront per exterior elevations and floor plan. If the existing horizontal grille is used, the contractor shall renovate to like new condition ❑ ** ** Tenant shall provide and install a security barrier where required. All Security locks (s) and key stations shall have "U- Change" cylinders. U- Change cylinders will be coordinated through security vendor and will be installed by local locksmith. Motor to be sized per the manufacturers recommendation and provided with automatically reset thermal overload protection (battery back up as requested.) The control operator shall include an interlock system to prevent the operation of the door while locked (see drawings.) Emergency egress release shall be installed only as required by the local building code. The contractor shall coordinate the installation of the barrier with the tenant and the installing contractor. The contractor shall include the construction of all support frames, soffits and enclosures necessary to complete the storefront per the project documents and the barrier manufacturer requirements. All exterior components to be enclosed in a minimum 22 ga. weatherproof enclosure. If an existing security barrier is to be reused the contractor shall renovate to "like new condition. PHII HZ 3 - 06 - 07 r8 Existing P55 Landlord DNA Contractor Contractor ❑ ❑ ❑ Section 08410 WORK SCOPE DESCRIPTION ❑ * * ** Steel Roll - up Door - by McKeon Door (Slat type F2.) Locks shall accept American model 700 or 701 hasp type locks. Motor on all gates 10' -0" wide or larger. Current equals; Overhead Door. ❑ * * ** Perforated Roll -up Door - by DynaFlair (Model Sentinel.) Slat minimum 22 ga. galvanized steel. Motor on all gates 10' -0" wide or larger. Current equals; AlumaTek Inc, Ameridor Industries Inc., McKeon Door and Overhead Door. ❑ * * ** Security Perforated Roll -up Door - by McKeon Door (Model PF.) Slat of minimum 16 ga. galvanized steel. Current equals; AlumaTek Inc. ❑ * *** Sliding Grille - by Overhead Door (Model # 680, SGN.) Intermediate mullions (min. 5' -0" o.c.) Trailing rail to provide full closure with the adjacent building surface. Current equal: AlumaTek Inc., Secure America or DynaFlair or Mobilflex sliding grille. ❑ * * ** Perforated Sliding Door - by McKeon Door (Model PF.) Slat of minimum 22 ga. galvanized steel. Current AlumaTek INC. ❑ ** * ** Security Grille - with Lexan inserts by Overhead Door (Model # 671, NGN.) Current equals: AlumaTek Secure America, Metro Door, and DynaFlair. ❑ * * ** Scissor Gate - by National Gate (Model # DC 300.) Current equals: None at this time. ❑ * * ** Emergency Battery Operation - by PowerGuard Corp. Operator to provide stand -by, manual and automatic operation through an interior and exterior accessible system. The system shall have dual gate, open /close sensibility and to be fully integrated with the barrier interlock system. Battery to have a minimum life of 2 years, with a max. Automatic recharge duration of 12 hrs. ❑Provide and install storefront, Kawneer Framing & Door Trifab VG451, center section, flush design 2 "x4 1/2" profile, extruded aluminum with clear anodized aluminum finish, #17, with 4" base, or approved equal as manufactured by CR Laurence, Arcadia AR450, Vistawall Series 3000, US Aluminum Corp IT451. (Provide 1 intermediate glazing clamp at mid -span of each open wall to glass joint and glass to glass joint. Complete door frame width of 3' -0" x 7' -0" Kawneer doors (770 -449- 5555). ❑ "190" Narrow Stile Door to match, or 3' -0 ", 3' -8" X 7' -0" if LL required, with door, US26D hardware, in clear anodized aluminum, finish #17. If bulkhead is mandatory, height shall not exceed 18".**** Tenant shall provide and General Contractor shall install, on freight door and other exterior doors when indicated, one (1) Security lock, Double 08712 Defender Quick Release Alarm /Lock Model #DD -QRA (door width 3' -0" or 3' -6 "), manufactured by Phoenix Industries, in accordance with manufacturer's recommendations or Detex when Double Defender is not available. ❑ 48" freight doors advise P55 Purchasing (785 - 295 - 6080); for glass exit doors provide Detex. Detex units to be specified on plans. ❑ Supply and install security peephole as needed. 08712a Provide and install all interior doors as per documents door schedule and to be no less than 18GA hollow metal. Provide 3, 4 1/2" x 4 1/2" x US26D BB butts, and Schlage lockset "S" Series (Saturn) x (510D Passage /540D Bathroom) x US26D, and Glynn- Johnson 1153M floor stop. Paint doors to match adjacent walls; On the sales side, install the 3, 1 439 PHII HZ 3 -06 -07 r8 Existing P55 Landlord DNA Contractor Contractor ❑ C Z H ❑ ❑ ❑ ❑ x x k' NOV 29but PERMIT E.N Project North R e v i s i o n s Date I I/21/0'1 Description OWNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 10RI3IWD, WA 98033 P:425.827.2100 F:425.828.6899 /7l 'THOMAS LE: SPADER sTATr Oi: l.ASHINGTON STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA SPECIFICATIONS DRAWN BY: GP DRAWING NAME: 01652A5.dwg DATE: I (/21/01 PROJECT NO.: A07 -652 Section 08800 (storefronts Interior & exterior) Section WORK SCOPE DESCRIPTION Boston Bumpers (Shipped with other provided items) series 40, color 193: Polar White, size: 33" L w /bumper, aluminum channel and 6 end caps. Install bumper at centerline of bumper 8 ", 42 ", and 62" A.F.F. All doors are 7-0" high. Contractor shall provide and install Rockwood Mfr. Trim Protector Bar #R111LPB for 1 3 /4" HM door & #R115LPB for 1 3 /4" wood door. ® Add trim protector ® Office / toilets off corridor and toilet rooms off sales area to have push button entry: Kaba IWO Mechanical Lockset L1000 series or approved equal. ® Provide and install Pair of 3' -0" x 7-0" Kawneer (770 -449 -5555) 190 entrance door(s) to swing outward, finish to match storefront finish. If LL required provide 3' -0" or 3' -6" x 7' -0" door. Provide single cylinder dead bolt security lock(s) with keyed cylinder. U- Change cylinders wil /be 8712b coordinated through security vendor and will be installed by local locksmith. ❑ Provide and install automatic door closer Corbin - Russwin, DC2200 series x 693, or approved equal. Entrance door (s) to have 1/4" clear tempered glass and to have top, bottom and standard intermediate offset pivots. (See door locations on documents attached.) Pull to be style: #17 (std), Clear Anodized Aluminum for Kawneer doors. ❑ Storefront 4" bottom channel glazing base is to be Kawneer Tri -fob, CR Laurence in Satin Natural, (Clear Anodized Aluminum) and associated system products. Interior use requires 3/8" tempered glass greater than 3' -0" wide and 1/2" less than or equal to 3' -0" wide with frameless butt joints. Provide glass clips if 9' -0" or above for glazing panels, if required by code. Joints between glass panels and jambs, to be a maximum of 3/8 ", uncaulked, unless required by city, state or local code. * * ** ® Exterior glass shall be 1/4" clear polished plate or float glass. CBD's to have butt joint glazing system. Provide glass sections of at least 48" clear dimension, to allow maximum visibility into premises. Glass height shall be minimum 9' -0" as measured from finished floor, but in no case shall extend higher than Tenant's ceiling. Glass shall be tempered or insulated as required by state and local building codes and environmental conditions. Reuse of existing storefront glazing systems should be clearly noted on plans and have prior approval from PSS. * * ** DIVISION 9 -- FINISHES WALLS, ACOUSTIC, FLOORING AND PAINTING Provide and install demising walls, which shall extend from finished floor to roof deck structure and shall be nominal 2" x 4" steel or wood studs, 16" on center, insulated with 3 1/2" R -11 fiberglass batts, Kraft paper barrier one side, sheathed with 5/8" type X gypsum board both sides and rated for one (1) full hour fire resistance. Seal penetrations at demising wall to deck. All demising walls to deck to have fire stopping per local 09111 code. All exterior wall surfaces shall be finished with 5/8" type X gypsum board with minimum wall composite of R -11. Walls shall be taped, sanded and ready for paint. If the demising wall is existing, contractor to confirm that the entire wall meets this specification. On all exposed columns and other high impact areas as shown on drawings, use National Gypsum, Hi -Abuse XP Wallboard in lieu of standard 5/8" type X gypsum board. On all exposed corners, after appropriate finish, install Tri - guards clear Lexan Corner Protectors, 90 degree TG8118, 1-1/8"x1 - 1/8"x8' 800/783 -8445. Critical: All walls straight /plumb. See plans for blocking layout. Remove excess adhesive, leave in clean condition. PHII HZ 3 -06 -07 r8 WORK SCOPE DESCRIPTION All exposed wall surfaces in the Sales Area below 7' -O" above finished floor or stair nosing line, not covered by shoe shelves, fixtures or mirrors 09950a shall be covered with Zolatone or epoxy paint per section 09900a. See finish schedule and interior elevations for colors and finishes. Walls adjacent to slat walls, wall fixtures or fins, finish will extend to 9' -0" aff DIVISION 10 — SPECIALTIES Provide and install two (2) 5 pound A.B.C. type portable fire extinguishers (or as required by code), J. L. Industries, Fyr- Fyter, General, or Kidde, 10522 complete with wall hanger; install one (1) in office next to electrical service panel; install one (1) in sales area at back side of back wrap or location required by code or building inspector. Provide and install the following equipment, or approved equal, in each restroom: ® One (1) 18" x 36" x 1/4" plate glass mirror set a maximum of 40" a.f.f. Bobrick No. B -165 or Bradley No. 710; IM one (1) 10800 Miami Carey No. 6011 paper holder, or Bobrick No. B -685, or Bradley No. 5084, and ® one (1) Rubbermaid #2364 "Easy Change surface mounted roll paper towel dispenser or equal. Remodel or reuse of existing toilets requires existing internal flushing components to be refurbished to like new condition. ❑Provide and install handicapped hardware at all locations specified by local, state or national code, as required. Grab bars shall be as per code; 10800a minimum 18 gauge stainless steel, smooth, #4 polished satin finish, concealed mounting. ❑ Contractor to confirm existing grab bars meet code requirements and information shown in plans. Adjust to meet ADA requirements or replace as needed to meet compliance. All store signs required by Tenant shall be provided and installed by 10800b Tenant's sign contractor. Signage electrical connections and electrical stubs provided by General Contractor, final connection by electrical contractor. General Contractor shall install emergency lighting exit signs that may be required by local code. 10800c In one restroom provide and install (4) 24" x 8" wall mounted wire frame shelves mounted at 36 ", 48 ", 60" and 72" A.F.F. 10914 Install metal locker / coat rack (L unit) supplied by Payless, as shown on the plans. Other PSS provided lockers may be supplied. Coat racks to be provided by General Contractor IF not shipped with locker. 10915 Provide and install for the construction type, the hardware necessary for the exterior seasonal banners per the construction documents. DIVISION 11 -- EQUIPMENT Tenant shall provide and contractor shall install, after premises are closed 11030 in, a safe(s) (approximate weight of 170 lbs.) under register counter bolted to the floor. 0 Biometric pad or hub connections- setup and configured by other PSS vendors. PHII HZ 3 - - r8 Existing PS5 Landlord DNA Contractor Contractor E I H ❑ ❑ Z ❑ ❑ ❑ Existing PSS Landlord DNA Contractor Contractor ❑ ❑ n ® n ❑ T I O ❑ E I D ❑ ❑ ❑ ❑ ® ❑ ❑ x x x n n Section WORK SCOPE DESCRIPTION Provide and install all non - bearing partition walls at locations shown on 091iia floor plan, exhibits /drawings, which shall conform to Section 09111 above, except that it may extend only 6" above finished ceiling and requires no insulation. Walls shall be taped, sanded and ready for paint. Tenant shall provide and Contractor to install ceramic floor tile (in strict accordance with P55 installation specifications) per floor plan. Use Graniti Rendre, Marmi, Palissandro (off white color), Size: 16 "x16 ", Finish: Honed Sanded Grout Color: C -Cure, #25- White. 09330 ® Per plans and finish schedule . Grout sealer to be "Invisible Finish" Penetrating Sealer by Aquamix, Inc., 562/946 -6877. Butt tile joint required to minimize joint. (Contractor to confer with PSS Project Manager prior to commencing with tile installation.) Contractor shall be responsible for the condition of the substrate in order to facilitate acceptable limits for the proper application of ceramic tile. In all cases of wood framed floors, use 2" conc. setting bed as shown on plans. Contractor shall provide and install ceramic /porcelain /natural stone wall tile as shown on the documents. Material shall be per the finish schedule. Note: Stone Source Basaltina Tile is provided by PSS 09330a and installed by PSS GC. Other wall tile is provided and installed by PSS GC. Installation shall be per Tile Council of America Method W242- Latest Edition for C -36 gypsum board or plywood and type II organic adhesive. Butt tile ioint required to minimize joint. Option #1 09511* Section 1.5440a Provide and Install acoustical lay -in tiles and metal suspension system throughout sales area. Acoustical panels shall be Armstrong Dune, 2'x4'x3/4" Second Look II, #2712 angled tegular, class A: color White (877 - 276 -7876 or 800 - 572 -8324; email :techline @armstrong.com). If fire code required, provide Armstrong #1831, 2'x2'x5/8 ". Metal suspension system is to be Armstrong Prelude XL 15/16" #7300 Intermediate color: White. Installing contractor shall coordinate with electrical and mechanical contractors on job site to provide support for light fixtures, grilles and ceiling diffusers. Restroom ceiling is to be acoustical lay -in or gypsum board if required by code, at a ceiling height of 8' -0 ". See plans for type. If ceiling system is existing, contractors to confirm that seismic compression struts are existing, if required. It is not the intent of this specification to provide a one hour rated assembly. Design of space shall allow a ceiling height of 12' -0" , unless otherwise approved in writing. Installing contractor shall coordinate with electrical and mechanical contractors on job site to provide support for light fixtures, grilles and ceiling diffusers. Restroom ceiling is to be acoustical lay -in or gypsum board, verify per code, at a ceiling height of 8' -0 ". If ceiling system is existing, contractors to confirm that seismic compression struts are existing, if required. See plans to verify: Main ceiling height at 11' -0 ", see plans for variation at POS counter globe light in "A" level design to 12' -0" aff and provide Axiom trim as required. CEILING HEIGHT SHALL BE PER DRAWINGS PHII HZ 3 -06 -07 r8 WORK SCOPE DESCRIPTION DIVISION 12 — FURNISHINGS Provide all labor and materials necessary for the installation of the Slat Walls, Corner Boxes, Fins, Register Counter, Miscellaneous Merchandising Fixtures, and other items of plastic laminate faced Casework, as provided by tenant. Furnish, install, clean, and touch -up to a LIKE - NEW condition items as required including miscellaneous items not specifically called out. 12304 Any Tenant supplied items that are not NEW shall be carefully inspected, cleaned, and touched up to a LIKE NEW condition. Items discovered to be NOT ACCEPTABLE due to non repairable damages, and / or color variations should be brought to the Project Manager's attention as soon as possible so that replacements can be ordered. The contractor is to insure that ALL installed items shall be clean and free of dirt, dust, old labels, marking, packing tape, etc. prior stocking of the store. DIVISION 15 -- MECHANICAL -- PLUMBING AND HVAC Provide and install, or modify existing, sprinkler system in accordance with all codes having jurisdiction, if required. Sprinkler heads shall be 15330 located in conjunction with Tenant's reflected ceiling plan and floor plan. Design shall take into consideration shelving and top stock. Contractor is responsible for - coordinating this work with all other trades. Subcontractors shop drawings shall be used for all approval submissions required. Prior to commencement of any work the lease space fire sprinkler system 15330a shall be verified and confirmed to have components that have been updated or not listed in the Tyco Fire Products voluntary recall (800 -871- 3492). Effected specific models of Central and Gem wet sprinklers and Central and Star dry sprinklers and all others listed at www.sprinklerreplacement.com that are found within the demised space should be replaced by Landlord prior to occupancy and building inspections. Consult with Architect for placement of sprinkler heads in perimeter lighting alcove when applicable. See plans. ® If required by code, provide and install drinking fountain(s) Oasis P8AC or PBACSL if hi -lo (w/ slaved unit configuration) is required ®, P- trap(s), supply with stop at location shown on exhibits /drawings 15440 attached. Mount drinking fountain nozzle(s) per latest code or as shown by plans. Drinking fountain installation shall comply with all local and governmental ordinances as required. Provide required plumbing and electrical rough -ins. Equivalent by Elkay. Provide and install wall -hung white vitreous china lavatory (ies) (American Standard #0124.024) (with hose adaptable faucet fitting including back flow valve) and floor- mounted white vitreous china elongated rim water saver toilets (American Standard 2168.100) with open front seat in restroom(s) as required by local code, Eljer or Kohler, all supplied with stop.. Where required by local code, lavatory substitution may be American Standard #9141 series with 7400.172H faucets. Pressure assisted tanks required. 15440b When required, provide and install a thermoplastic wall mounted service sink (Mustee #15W, 1- 800 -321- 3128). PER DRAWINGS 15440c When using service sink, delete hose adaptable faucet fitting on lavatory and use American Standard 2.385 series, single control faucet. PHII HZ 3 - - r8 Existing PSS Landlord DNA Contractor Contractor ❑ ❑ ❑ ❑ ❑ E Existing PS5 Landlord DNA Contractor Contractor x x O D ❑ ❑ ® ❑ ❑ N C ❑ ❑ ® ❑ ❑ ❑ ZI ❑ n u ❑ ❑ ❑ ® ❑ Section WORK SCOPE DESCRIPTION Provide and Install Gypsum Board Ceiling Suspension System As indicated on the Drawings for the Sales Area. a. Ceiling Suspension: As scheduled on the Drawings. Option #2 b. Gypsum Board Suspension System: Similar to Armstrong "Drywall Grid 09511* System; 1 -1/2 inch face; ASTM C635 heavy duty classification. All above ceiling HVAC, electrical or other systems must be coordinated and confirmed before final completion of ceiling systems. Access panels shall be coordinated with critical components for maintenance and verified with PM at time of install. See plans for locations. See Finish Schedule for Paint colors. PSS provides and General Contractor installs Mannington iCore Flooring System, 5 "x48" plank. See construction documents for iCore specifications, locations and installation guidelines. Note: Sales Area to receive iCore for New /RL stores and A level remodels. C level remodels to receive iCore and carpet. Transitions, see plans for 09650 locations: iCore metal track with matching wood faux look, t -track (94" length) with silver U- channel, Schluter Reno Ramp at threshold, ]ohnsonite Bendable track #MTC -00 -A. GC shall view DVD and install per instructions. GC to confirm with PSS PM that installation crew has seen and understands the install video http: / /web.mac.com /studio 9302 /iWeb /Movies /iCore %20lnstallati on.html IM General Contractor provides and install base in sales area per construction documents. Provide and install vinyl composition resilient floor tile and "Roppe" 4" coved rubber base, color: Roppe Black #100, in office, corridor and restroom(s). Tile shall be 1/8" x 12" x 12" Armstrong Classic White No. 09650a 51911 or approved equal. General Contractor provide and install 1/8 "x12'x12" VCT for underlayment (if needed) use per plan details for products listed under 09650. Sales Area base to be Pie at exposed walls and columns. ® DNA Provide and install stair and landing surface with matching risers and stringers. System shall be Roppe standard profile, raised circular design. Stair tread with safety yellow nosing indicator required at top tread. All other material shall per plans. ® * * ** Entry mat(s) provided by tenant, installed by general 09655 contractor, typical mat size is 3' wide x 4' deep, color: black. One mat per each entry door per plans. ❑ ****Provide and install exterior entrance tile as shown on the construction documents. Tile shall be R.C. Musson (330 -773- 7651), dark gray, fluff-cord strip tile in alternating parquet pattern. Tenant shall provide and General Contractor shall install carpet in the sales area. Tenant shall provide the freight, mastic, and seam sealer. Installation shall be performed only by a qualified carpet mechanic experienced in glue down installation of 12' -0" enhancer - backed material. 09688 Carpet shall be installed sidewall to sidewall starting at front of store. Prior to installation, all minor floor irregularities shall be repaired and surfaces thoroughly cleaned, removing all dirt and grit. Mastic shall be applied only with notched (serrated) trowel in accordance with manufacturer's recommendations and carpet specifications sheet. Tenant shall provide and contractor to install metal carpet tile joiner at ceramic or vinyl flooring system edge. Contractor shall provide and install a saddle threshold (heavy -duty, flat top) 1/4" high and 2 1/2" wide, PHII HZ 3 - 06 - 07 r8 Section WORK SCOPE DESCRIPTION Provide and install for one or two lavatory(s), one (1) 3 kW, 120 volt, 1 phase instantaneous electric water heater as manufactured by P.V.I. Industries, Inc. (800/433- 5654), Model #3.0IE -120V or equivalent by I.T.S. Contractor to verify compliance with applicable code and 15450 ordinances prior to ordering. 240 volt requires model # 3.5IE -240V. 277 volt requires a 4kW Model #4.1IE -277V (this unit is also available in 208 volt). Insulate all exposed H.W. pipes. See plans for size of circuit & breaker. If codes require tank type hot water heater then the size should be as small as allowable. The location should be as close as possible to the point(s) of use with safe guards for leakage, such as a drain pan with overflow to floor drain. Provide and install smoke exhaust and /or fire alarm systems as shown in construction documents in conformance with all applicable regulations 15600 and local requirements including ADA. The equipment shall be compatible with the Mall or Landlord's equipment where applicable. Contractor shall confirm, in writing to the project manager, the landlords' acceptance of system. Provide and install ventilation for the entire premises including office and restroom. Air supply and return ducts (No return air plenums allowed) shall be concealed between finished ceiling and roof deck (see construction documents). Insulate exterior of all supply and return air 15781 ductwork. Flex duct to diffusers in maximum length of 6 feet or less per local code. HVAC ductwork design is to be optimized for cost savings through shape, local standard practices, re -use of existing systems or other means that don't impact the store design standards Ducts /Diffusers to be square /rectangular Baked enamel off -white finish. The Mechanical Contractor shall procure the services of an 15781a independent air balance and testing agency, to balance, adjust, and test air moving equipment, and air distribution and exhaust systems. The testing and balancing firm shall be certified by NEBB or AABC and all work shall be performed in accordance with these organizations' published procedure manuals. The balancing agency shall prepare a certified report of all tests performed. The report shall be written on standard forms prepared by NEBB or AABC or facsimiles thereof. The balancing agency shall submit 3 copies of this report to the Mechanical Contractor who shall submit them to the P55 Project Manager for review and distribution, including to PSS Corporate Construction Services. This report and warranties described above must accompany the Contractor's request for final payment. NOTE: Payless ShoeSource has a National Account with Carrier Corporation for the HVAC products. All HVAC bidders should contact their nearest Carrier distributor for pre - determined pricing and availability, or National Accounts Department. General Contractor to allow 2 -3 week lead -time. Architect to send HVAC PDF plan to Carrier upon completion of construction drawings via email. Andrea.Barberi @carrier.utc.com - 704 - 494-2583 Carrier Engineering Support — Technical Questions 9300 Harris Corners Pkwy., Suite 220 Charlotte, NC 28269 PHII HZ 3 -06 -07 r8 Existing PSS Landlord DNA Contractor Contractor ❑ ❑ ❑ Z ❑ E E L D E I D E ❑ X H E ❑ ❑ ❑ Existing PSS Landlord DNA Contractor Contractor ❑ A ❑ ❑ IA n ❑ ❑ ❑ ❑ ❑ ❑ Section Provide and apply one (1) coat ProMar PrepRite 200 primer coat and a minimum of two (2) coats of "ProMar 200 Latex Eg - Shel base paint to interior walls; H.M. doors, frames (shop primed), and all exposed metal railings or columns to be painted with a minimum two (2) coats of "Water Based Catalyzed Epoxy" paint, P1E. Call Sherwin Williams @ 785 - 267 - 1252 or email sw7212 @sherwin.com with paint questions. Paint shall be applied 09900 in accordance with the manufacturer's recommendations. Finished surfaces shall be free from runs, drops, ridges, waves, laps, brush marks and variations in color and texture. The hiding shall be complete and each coat shall be applied to produce a film of uniform thickness. See construction documents for paint locations. P1 -Sales Area, Office, Stockroom. Toilet Rooms and Corridor:See Plans and Finish Schedule. Provide Zolatone /Polymix as shown on construction documents (816-898 - 09900a 1390) Denny Gragg, Architectural Finishes, Inc. (polomvxafi@AOL.com or www.zolatone.com). See plans and finish schedule. Exterior sign band area(s) color per construction documents. This may 09900b be accomplished by painting the existing surface or applying material matching this color (see plans). Coordination with the sign installer required to painting. Contractor to contact P55 project manager for sign installer information. Provide plastic laminate covered wall /partition surfaces as shown on the construction documents consisting of: Particleboard substrate meeting CS -236, industrial grade, thickness indicated, minimum 45# density. Plastic laminate meeting Nema LD3, grade 10 or 12. Color and finish as indicated. For fire rated wall /partitions, substrate shall be equal to Willamette Industries, Inc. "Dura Flake FR" fire rated particle board, with flame spread 20 and smoke developed 25, UL723 and ASTM E84. 09950 Contact adhesive as recommended by laminate manufacturer for field laminating to particleboard substrate. 4 Section WORK SCOPE DESCRIPTION aluminum by Macklanburg- Duncan 405/528 -4411 or equal, at the office door. Contractor shall provide and install "Roppe" 4" rubber base, Color: see finish schedule, as shown on documents. Contractor to provide and install Wood Base in Sales Area: Painted MDF, 1 /z "x4 ", Color Paint: P1. Install the /cpt joiner(s) after wall fixtures are installed. Do not put vinyl trim under CF -1 Alpolic. All joints to occur under floor fixtures. Ceilings per plans:See Plans and Finish Schedule. Install particleboard substrate to metal studs with appropriate self - drilling /tapping flat -heat countersunk fasteners at spacing indicated or required. Sand exposed surface as necessary fill fastener countersink holes and align joints in substrate to prevent telegraphing through plastic laminate. Apply adhesive, 100% coverage, on exposed face of substrate and on unexposed face of plastic laminate. Apply two coats of adhesive to particleboard substrate allowing first coat to become dry to touch before applying second coat. Apply adhesive coated plastic laminate to substrate as recommended by manufacturer. Roll with hand "3" roller over all laminated surfaces to assure 100% contact between plastic laminate and substrate. PHII HZ 3 -06 -07 r8 WORK SCOPE DESCRIPTION Contact: Deborah Roy -Jones (For order placement and /or delivery information) e-mail: Deborah .Roo- JonesPcarrier.utc.com (800 -690- 1086) All other questions: Bill Jackson -Sr. Acct Mgr.; 952 - 226 -3072; f:860- 660- 0824.e -mail: Bill.JacksonOcarrier.utc.com If Section 15781a is by the Landlord, the Landlord must submit to Payless ShoeSource a duct work/supply /diffuser layout complete with sizing and load calculations The unit serial and model number, and the landlord must meet die air balance requirements as outlined above New HVAC System: Provide and install Carrier heating and air - conditioning roof top units (as per PSS Design Standards with SEER rating of no less than 13 for 3 to 5 ton single phase units and 11 for 6+ ton 3 phase units). Provide tenant with five (5) year written warranty including labor and parts on air conditioner compressors, ten (10) year written warranty including labor and parts on gas -fired heat exchangers 15781b and one (1) year written warranty on complete installations. Provide tenant with operating instructions on all equipment. New HVAC system to include utility connections, fire and smoke alarms, disconnects, roof curbs and thermostat sensors. Thermostats and sensors provided by tenant in FFE shipment Use of Non - Carrier units require prior approval and may require additional conversion adapters to work with tenant supplied thermostat and sensors. ❑ *4-4.4 Existing heating and air conditioning systems, including all components shall be cleaned and serviced to full working capacity. 15781c Existing ductwork, thermostats and controls shall be modified, cleaned, or replaced as necessary in accordance with documents attached. Air balance report shall be completed per section 15781a with copies e- mailed to Elaine.Boose @pavless.com (785- 270 -7807) in a PDF or MS -Word format. Outside design temperatures shall be: Winter -99 1/2% design dry bulb 15781d column; Summer- 1 % design dry bulb and mean coincident wet bulb column from latest ASHRAE Manual. © * * ** *Inside design temperatures and thermostat set points shall be: 15781e Heating 68 degrees Fahrenheit; Cooling 75 degrees Fahrenheit dry bulb and 67 degrees Fahrenheit wet bulb. The nighttime set back shall be 55 degrees Fahrenheit Heating and 85 degrees Fahrenheit Cooling. ® * ** *Provide and install 6" diameter duct for 100 CFM restroom 15890 exhaust fan as required to duct through wall or roof, complete with wall or roof cap, as required by local code. 15952 ®New Thermostats: In all installations General Contractor uses the provided Custom Carrier Debonaire thermostat and installs one (1) thermostat 8& sensor for each matching rooftop unit per plans and manufacturer's instructions. Sensors missing from shipment should be field replaced by contractor - see section 15952 for model #. ❑ ** ** ® Mount thermostat(s) at 48" above finish floor as indicated on elevations of office desk. Tenant supplied Carrier remote sensor(s), model 33CSSEN -01, are mounted at 5' -6" above finished floor as shown on plans. This is a 3 -wire sensor for PSS thermostat; other sensors WILL NOT WORK. Non- Carrier units to be checked for PHII HZ 3 -06 -07 r8 Existing PSS Landlord DNA Contractor Contractor ❑ Z D E El x LI D ❑ 7 H E ❑ E O D Existing P55 Landlord DNA Contractor Contractor ❑ ❑ N ❑ ❑ ❑ ❑ H ❑ ® u ❑ ® ❑ ❑ ❑ ® ❑ n ❑ ® u NOV Z9au/ PERIVin Project North R e v i s i o n s 0 O • ■ ■ • ■ ■ Date I (/27/07 Description OWNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRKLAND, WA 98033 P:425.8272100 F:425.828.6899 STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA SPECIFICATIONS DRAWN BY: GP DRAWING NAME: 07652A51.dwg DATE: I I /27/07 PROJECT NO.: A07 -652 Section 16010c WORK SCOPE DESCRIPTION compatibility with P55 thermostat and sensor. ALL compatibility issues to be addressed with Project Manager after checking with Carrier (section 15781a). Project Managers must specify number of Thermostats and sensors when ordering from Pay less Purchasing department. DIVISION 16 -- ELECTRICAL LIGHT AND POWER, FIXTURES AND LIGHTS Contractor installation of circuited fixtures or devices shall include all 16009 supplies and materials to be fully functional when complete. ❑ : * * ** Provide and install - "• 1 "H' 20 amp circuit, wiring and junction boxes, routed through timer, for all Tenant's * * ** signing * * * *. ❑ Provide Intermatic #T171 time clock and Square D class 8903 electrically held lighting contractor having two 20 amp poles and enclosure, to control sign specified.❑ * *°"* 16010 ❑ Install Intermatic K4200 Series (specific number varies per power supply) photo electric cell to bring all signs on at dusk and set time clock to turn all signs off one (1) hour after closing. Photo electric cell to be located so that ambient light will not activate it. ❑ * * ** Electrical contractor to make final electrical connections to all signage and set per time clock riser diagram as indicated on documents. Provide adequate access to allow for installation of Tenant's sign * * * *. 16010a Such access to be secured. Location to be confirmed by Tenant in least conspicuous location. Refer to: Section 15781. Contractor shall be responsible to confirm phase, provide and install 16010b proper sized wiring, circuit(s) and junction box (es) and make primary connection to grille motor(s), interlocks, and install key station(s) provided by manufacturer. ❑ * *** Provide single circuit receptacle with plug cap, connected to water heater provided by Plumbing Contractor. Individual Letters and Under Canopy (Soffit) Sign: Location per documents attached. Fabrication and installation of signage is 16010d by P55 approved sign contractor. P55 Contractor and/ or LL Contractor(s) collaboration with sign contractor's installation of signs is required on all projects. Existing Project or New Pylon Sign: Location per documents attached. If lbOlfle new meter is required, install with timer and secure timer with padlock, furnish tagged key to Tenant. Convenience Outlets: Provide and install duplex outlets as shown on construction documents at 15" a.f.f. unless otherwise noted. All outlets 16130 and outlet covers to be brushed aluminum. ❑ * * ** ❑ Provide chime receiver outlet per plans. ❑Provide ceiling mounted outlet(s) at storefront as shown in plans. PHII HZ 3 -06 -07 r8 Existing P55 Landlord DNA Contractor Contractor LI l n XI n Section WORK SCOPE DESCRIPTION ® Register Counter Outlets: Provide five (5) separate 1" dia. Code compliant conduits per plans. (1) to be a security system conduit from back office to wall near register counter, then through floor slab to register counter location as shown on the per plans. Coordinate trench location with access panel in cashwrap per plans. Contained in (2) of the conduits shall be two (2) 20A dedicated, grounded circuits, one per conduit circuited to j -box located in access area. Cashwrap should contain pre -wired 5 duplex outlets with flexible conduit for attachment connection to circuited j -box. Conduit shall be rigid metallic or electrical metallic tubing (EMT). If circuit is within or under concrete slabs then rigid metallic conduit shall be used. (1) Conduit is for circuit to energize the cashwrap lights per plans. ®Switched circuit required for cashwrap lighting. Convenience out lets in demising walls to be per code by LL. PSS GC responsible for all outlets indicated on plans including partition walls, cashwrap, wing walls, corner boxes, and outlets 16130a for Loss Prevention equipment. All conduits are required to have (2) pull strings left in place. Conduits shall be labeled at both ends per descriptions noted on plans. 16130b 161470 Provide conduit that is acceptable by local, city, state, or national code and landlord. All 3-boxes are to be mounted as low as possible in counter access panel space. If Cashwrap does not include duplex outlets install new. Provide two (2) separate 1" conduits from telephone terminal board in office to ceiling cavity above. Also provide 1" conduit below floor at register counter to demising wall and stub up to ceiling cavity above, as indicated on the plans. ®The tenant shall provide and install the loss prevention items per plans. The contractor shall provide and install the security system conduits with at least 2 dedicated 20a circuits. One circuit has one duplex outlets mounted above ceiling at bulkhead above entry door. The other one is mounted above ceiling on coiled lead above cashwrap per plans. Outlet above door to be no more than .5 V over neutral and ground. ❑ * * ** ®DVR requires nailer bd. per plans. Nailer Boards are (2) 1 "x10 "x24 "white pine boards mounted above file cabinet to create a 20 "x 24" equipment Counting area. ELECTRICAL SERVICE. Provide to the demised premises separately metered electrical service as outlined below in Option #1 or Option #2. All work performed shall be in accordance with applicable codes. All apparatus, equipment, materials, and installations shall conform to standards of National Electrical Manufacturers Association (NEMA), Underwriters Laboratories, Inc. (UL), and the Occupational Safety and Health Act (OSHA). LIGHT SWITCHING NOT ALLOWED AT PANEL. See Construction Documents for wall switch location. Locate all electrical equipment in office area. PSS Signage is always circuited through time clock. * * ** 120/208 VOLT 3 PHASE 4 WIRE SERVICE - Unless restricted by Landlord's tenant improvement guidelines, provide minimum 200 amp service to the demised premises. If size is restricted to less than 200 amps, provide largest service permitted by Landlords tenant Option #1 improvement guidelines. 16470a Provide and install, as a minimum. one (1) 225 amp, 120/208 volt, 3 _phase, 4 wire _42 circuit distribution panel with solid neutral andlground PHIL HZ 3 -06 -07 r8 Existing PSS Landlord DNA Contractor Contractor ❑ n 171 H ❑ n ® ❑ ❑ ❑ Section Option #2 16470b 16500 16510 buss, complete with bolt -on circuit breakers. Circuit breakers shall be as required for mechanical equipment and signage (quantity, amperage, poles); with all remaining circuit breakers spaces shall be provided 20 amp single pole circuit breakers suitable for use with HID and /or fluorescent lighting loads. Water heater requires a 30 A circuit breaker. * * ** 277/480 VOLT 3 PHASE 4 WIRE SERVICE - Unless restricted by Landlords tenant improvement guidelines, provide minimum 100 amp service to the demised premises. If size is restricted to less than 100 amps, provide largest service permitted by Landlords tenant improvement guidelines. Provide and install, as a minimum, one (1) dry step down power transformer, 30 KVA, 480 primary, 120/208 volt, 3 -phase secondary. Provide and install, as a minimum, one (1) 100 amp, 120/208 volt, 3 phase, 4 wire, 42 circuit distribution panel with solid neutral and ground buss, complete with bolt -on circuit breakers. Provide 20 amp single pole circuit breakers suitable for use with HID and /or fluorescent lighting loads ,per_plans. Point of Sale System. The Contractor shall provide and install Global Store equipment rack nailer board per plans and provide pull strings in data and phone conduits for use by equipment installers. Documents pertaining to this work will be found in the plans. (1) Nailer board above tower is required —see r section 16130b for size — paint . The following is the procedure to be followed in reference to the lighting for stores unless noted otherwise: All lighting package standards by Tenant or Landlord to be provided through Villa Lighting as per specification section 16510. 1)When documents are completed, the Architect will submit lighting documents via e-mail and 2 " day shipping to: VILLA LIGHTING SUPPLY WORK SCOPE DESCRIPTION 1218 S. Vandeventer St. Louis, MO 63110 800/325 -0963 Direct dial: 800/644 -0087 ext. 103 Contact: Sue Myers - SueCa villaliahtina.com 2) At that time, Villa Lighting will create a preliminary lighting package for the proposed site and send a quotation to Payless ShoeSource Real Estate Purchasing and the Payless ShoeSource Project Manager. 3) The documents and C-1 Specifications indicate that the lighting package will be a tenant furnished item. 4) The Project Manager will release the lighting package from Payless ShoeSource Real Estate Purchasing (same procedure as other LHI and FF &E tenant furnished items) allowing 3 weeks for delivery. Voltage, verified through the General Contractor, must be shown on the release form. General Contractor is responsible to accept and inspect for correct quantities and /or damages. If damages occur, the Contractor will file PHII HZ 3 -06 -07 r8 Existing PSS Landlord DNA Contractor Contractor ❑ ❑ ❑ ❑ ❑ ❑ IX ❑ E ❑ ❑ ❑ ❑ I. ❑ Section WORK SCOPE DESCRIPTION 16510 claim and request replacement fixtures through the Project Manager. (con't) Any monetary losses incurred by Payless ShoeSource due to the General Contractor not filing proper freight claims will be deducted from the final draw. 6) G.C. is responsible for complete installation of lighting package in accordance with the documents, manufacturer's installation information, and governing codes. This installation includes all necessary work to distribute the power from the light switches to each light fixture, including any and all wiring, conduit, junction boxes, other materials and labor. 7) All communication with Villa is to be coordinated through Payless ShoeSource Real Estate Purchasing. General Contractors are not to contact Villa direct. 8) In cases of landlord turnkey jobs, requests for lighting must still be placed, by Project Manager, through Payless ShoeSource Real Estate Purchasing with a notation that the landlord (or appropriate entity) will bear ultimate financial responsibility. All billings from Villa will continue to go directly to Payless ShoeSource Real Estate Purchasing with the landlord invoiced from Payless ShoeSource for reimbursement. Provide and install smoke exhaust and /or fire alarm systems in conformance with all applicable regulations and local requirements 16600 including ADA. The equipment shall be compatible with the Mall or Landlord's equipment where applicable. All equipment shall be UL and FM listed. 16601 DESCRIPTION Light & Schedule MODEL NUMBER WITH LAMPS ...... ...__.... _.... General Lighting—down aisle: Semi - Indirect Fluorescent includes 36" cables & coil cord. * * ** A ❑ Al ❑ Ala B ❑ ** *Back office under shelf desk light purchased & installed by Contractor per location and specifications on plans If not specified use GE Ultra Thin Line 21" Product # 27401 order code # UCF21 /DXO. Exceline ProLinear Series Shallo Perforated, 32 W (F) (Sylvania Lot 287 =3 Lamp...T8...... 8' -0" X 10 "X 3'/2 " surface mounted fixture (for use with 9'-0" or lower ceilings) * * ** Metalux 8TP410 -232 TBW- 120V- AD- REL4P32RHTP-U (4 Sylvania FO 3235K lamps per each 8' -0" section) 4' -0 "x 10" x 3 1 /2 " surface mounted fixture (for use with 9' -0" or lower ceilings) * * ** Metalux P410- 232TBW- 120V- AD- REL2P32RHTP -U (2 Sylvania FO 3235K lamps per each5-0" section) 8 " -0" Office Strip Lights Lightolier SW242 RSHPFUNVO4QPS 4 Sylvania F0 3235K per 8' -0" section) PHII HZ 3 -06 -07 r8 �DD7 -�3 Existing P55 Landlord DNA Contractor Contractor ❑ ® ❑ ❑ ❑ u LJ u ❑ ❑ n ❑ ❑ ® n 0 ❑ Del i Section B1 ❑ c ❑ cv ❑ D2 ❑ D3 ❑ E ❑ E1 ❑ E2 Sure Lite LM -1 Sure Lite -ST -1 NYC emergency light * * ** Sure Lite - XR -5 -NY Emergency exit light Sure Lite SLX7ORWH Chicago exit light * * ** Sure LiteCHX -318 -C NYC exit light **** F II F1 ❑ 4' -0" Office Strip Lights =r• * ** Chicago emergency light * * ** Sure Lite EP -1 - R -UNY8 Recessed adjustable fixture "* *'* Recessed fixture (exterior) * * ** WORK SCOPE DESCRIPTION Lightolier 240RSHPFUNVO4QPS (2 Sylvania FO 3235K 4' -0" section) MR16 Track Head for spot lens lighting Whiff, LS [5egree . Beam Spread * * ** Halo Lazer Track Lighting LZR 401P Q50MR16C /NFL25 degree (EXZ) Sure Lites emergency light with battery (Install in grid rY ( g d ceilmg) :c: * *:m Sure Lites GC- 1505- 2- 19C(2- 02C -50 battery) light ry.._— ._..— __._..._ Sure Lites surface mount emergency li ht with battery: (install surface D1 ❑ mount) * * ** Lightolier LT1102PJ -CUL -S with trim LT1123 CUL (LAMP= GE75PARH NFL2S -130V) Lightolier H44T/448 (LAMP= GE75PARHNFL25 -130V) PHII HZ 3 -06 -07 r8 Existing P55 Landlord DNA Contractor Contractor ❑ ❑ ❑ ❑ ❑ ❑ LI ❑ Li ❑ ❑ ❑ ❑ x F ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ® n ❑ ® ❑ Del Section F2 ❑ H ❑ 2 x 2 White Louver Parabolic, 3 -light General lighting at front of K ❑ store. * * ** K1 LI M❑ N ❑ P❑ Q LI Exterior Graphics Light - Hadco WAM1 -A, Black *° * ** Q75CL Lamp# 39574 WL ❑ Chicago recessed fixture * * ** Lightolier HAH7TCP w /HA 410P flat trim or HA 78P eyeball Exterior door light 'k *' * Lumark MH- WL- 175 - 120 -TT PE -LL -BLK MT -LL -BLK wall pack, 175 watt Metal Halide ...., —... �._ Fan and light ": Nutone NE 8673P w/60 watt lamp Lightolier DPS2G9WP3FT120X3 -CUL (Sylvania FT4ODL/830 lamps) Transmitter /sensor (Mall & Non - Malls) * * ** OPTEX TD1OU OPTEX RC1OU Outdoor pole light * * ** McGraw CS7162BLK9ED28L w /400w MH lamp Remote Emergency * * ** Sure Lite 6x9 WGY Light (Exterior Bldg. Stock Dr. Exit) States: PA, N3. Buzzer Edwards #340A- G5 -24VAC Push Button Edwards #852 Transformer Edwards #592 Specialty item #1: Unused Specialty item #2: Unused z ❑ Specialty item #3: Unused WORK SCOPE DESCRIPTION Receiver AM1 ❑ RSA Lighting; COT41MH- WH- BK- 35 -27 -YK -120. Lamp: Quantity: 1, CDM35/TC /830, 3000K;type: MI 120 V; Mounting: Ceiling, Recess; Clear Lens PHII HZ 3 -06 -07 r8 Existing P55 Landlord DNA Contractor Contractor ❑ n ❑ ❑ ❑ n ❑ C ❑ ❑ u ❑ LJ n ❑ ❑ ❑ n H ❑ Del ❑ F ❑ x Section AM121 ❑ RSA Lighting; COT41MH- WH- BK- 35- 27- YK- LN32COAR -120. Lamp: Quantity: 1, CDM35/TC /830, 3000K; type: MH; 120 V; Mounting: Ceiling, Recess; Spread Lens * **'* RSA Lighting; 0 AM2 ❑ CDM 5/TC/830,3 00K; type; MH; 120 V;�Mou Ceiling, t Recess; Clear Lens RSA Lighting; COT42MH- WH- BK- 35- 27- YK- LN32COAR -120. Lamp: AM2a ❑ Quantity: 2, CDM35 /TC /830, 3000K; type: MH; 120 V; Mounting: Ceiling, Recess; Spread Lens * * ** RSA Lighting; COT43MH- WH- BK- 35 -27 -YK -120. Lamp: Quantity: 3, AM3 ❑ CDM35 /TC/830, 3000K; type: MH; 120 V; Mounting: Ceiling, Recess; Clear Lens AM3a ❑ RSA Lighting; COT42MH- WH- BK- 35- 27- YK- LN32COAR -120. Lamp: Quantity: 2, CDM35/TC /830, 3000K; type: MH; 120 V; Mounting: Ceiling, Recess; Spread Lens *'° ** ! PA1 RF1 ❑ RF2 ❑ SD1 ❑ SF1A ❑ SF1B n SF1C ❑ X ❑ Artemide Chandelier; 1051018- CASTORE 42. Lamp: Quantity: 2 globe heads, BC75BT1S /HAL/CL; type: INC; 120 V; Mounting: Ceiling, Stem ****1052018- CASTORE 35. Lamp: Quantity: 1 globe head, BC75BT15 /HAL /CL; type: INC; 120 V; Mounting: Ceiling, Stem * * ** Artemide Chandelier; 1053018 - CASTORE 25. Lamp: Quantity: 2 globe heads, BC75BT15 /HAL/CL; type: INC; 120 V; Mounting: Ceiling, Stem Metalux; RWW- I -32 -I -EBB; Lamp: Quantity: 1, F32T8/TL830 /ALTO; type: FL; 120 V; Mounting: Ceiling, Recess — 4' Lengths, Wall wash fluorescent recessed in soffit * * ** Mark Lighting; SLF4- EB- FA.(Slot light) Lamp: Quantity: 1, F32T8/TL830 /ALTO; type: FL; 120 V; Mounting: Ceiling, Recess. 3' or 4' Lengths. (order proper trim kits per edge condition, ie: gyp bd. Vs. acous. ) * * ** GE Gelcore; GEYGXLSI. Lamp: Quantity: 1, 6 LED'S /FT., (66 Lineal Feet for 2 lights); type: LED 12 V; Mounting: Ceiling, Recess * * ** Metalux; SNL -I -32 -EB8. Lamp: Quantity: 1, F32T8/TL830 /ALTO; type: FL; ❑ 120 V; Mounting: Ceiling, Recess; 4' length. (order proper trim kits per edge condition.) * * *"' WORK SCOPE DESCRIPTION Metalux; SNL -I -25 -EB8. Lamp: Quantity: 1, F25T8/TL830 /ALTO; type: FL; 120 V; Mounting: Ceiling, Recess; 3' length. (order proper trim kits per edge condition.) * "::;::< Metalux; SNL -I -17 -EB8. Lamp: Quantity: 1, F217T8/TL830 /ALTO; type: FL; 120 V; Mounting: Ceiling, Recess; 2' length. (order proper trim kits per edge condition.) PHII HZ 3 -06 -07 r8 Existing PSS Landlord DNA Contractor Contractor ❑ n ❑ CZ ❑ ❑ ❑ ❑ ❑ ❑ u LI n ❑ ❑ ❑ ❑ n ❑ ❑ LJ x Lightolier exit sign; LE- A- C -1 -RC. Lamp: Quantity: included: INC, LED; 120V; Mounting: Ceiling, Surface; type E; note: add battery pack to pass city inspections. * * * "° Section NOTE: All fluorescent lights are available in 277 volt if required. Acoustical Ceiling Tile: Armstrong Product: Dune; Product Number: 2712; ACT -1 ❑ Size: 2'x4'x3/4 "; Edge Detail: Angled Tegular; Color: White; Suspension System: Prelude XL 15/16 Inch, #7300, White; Notes: If Fire Code tile required: #1831, 2'x2'x5/8 "; Location: Sales Floor •F ** Acoustical Ceiling Tile: Armstrong Product: Cortega; Panel Product Number: 823; ACT -2 ❑ Size:2'x4'x5 /8 "; Edge Detail: Square; Color: White; Suspension System: 5/16" Grid System, Flat White Notes: Location: Office, Corridor, Fire code is standard. * * ** Aluminum Storefront Door Frame System: Kawneer Trifab or CR Laurence ADF -1 ❑ Finish: Clear Anodized Aluminum, No. 17 Notes: Location: Storefront windows, base, and door * * ** Carpet Walk Off Mat: C/S Group Entrance Flooring Product: Duration Carpet (Synthetic) FC -la ❑ Carpet type: Broadloom Color: #905 Wrought Iron Notes: Location: Storefront Entry_ —.. _ Carpet: Product: Shaw Custom; � Carpet type: Broadloom with Enhancer backing; I FC-1b I Color /Pattern: Gray /multi- color; Installation Type: Direct Glue; Base: see WB -1; C.... ,... ,. _.... Notes: Location: Sales Floor; See plans. * * ** Y Y Y Y V Y Laminate Flooring: Mannington; Product: I Core Plank; FC -4 ❑ Color /Finish: American Oak; Size: 5 "x48 "' Base: see WB -1 Notes: Location: Sales Floor * * ** molding Resilient Flooring Hite Bendable Vinyl G �ck #M -A and�p g v l � 40 Black. n ons oorin .. r positi.. .._.......dec Arm.__....._._. Size: 12x12x1/8" Color; White Notes: Location: Restroom. Provide Integral 4" High Cove Base * * ** FINISH SCHEDULE DESCRIPTION FC -3 ❑ WORK SCOPE DESCRIPTION Paint: Sherwin Williams; Color: SW 7006 Extra White Finish: Egshel on walls; Semi -gloss on doors /trim; Contact: 785 - 267 -1252 * Catalyzed water based epoxy Notes: Location: Sales floor, office, corridor, toilet room walls, doors, trim, wood base, sales floor light cove if applicable, see plans. * * ** Paint: Sherwin Williams Color: SW 6070 Heron Plume Finish: Egshel Notes: Location: Sales Floor Ceiling PHII HZ 3 -06 -07 r8 Existing P55 Landlord DNA Contractor Contractor ❑ ❑ ❑ ❑ ❑ ❑ n 1 ❑ 171 x LI ❑ ❑ LJ ❑ ❑ LI LJ V ❑ LJ ❑ ❑ n ❑ ❑ Li El F y .., 1' F NOV 2 9 2007 PERiVin CENT E-. Project North R e v i s i o n s 0 U Date I I /21/01 Description OWNER REVISION ■ ■ ■ ■ ■ FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRKIAND, WA 98033 P:425.8272100 F:425.828.6899 STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA SPECIFICATIONS DRAWN BY: GP DRAWING NAME: 01652A52.dwg Section P -3 ❑ P -4 ❑ P -5 LI Resilient Base: Roppe; Height: 4"; RB -1 n Configuration: Coved; Color: Black 100 Notes: Location: Office, corridor, toilet rooms, see plans. * * ** T -2 Tile —Stone Source; Product: Basaltina; Color: Gray T -3 n Size: 12 "x12 "x3/8" Grout Manufacturer: C -Cure; Grout Color: 115 Silver Contact: Notes: Location: Signband Tile, See plans. * * ** Marble- Emser Tile an...,,r. Natural Stone; Product: Bo tticino Classico; and Natural Bo assi Color: Off- white; Size: 12 "x12 "x3/8 M2 ❑ Contact: Judy McWard 323- 650 -2000, cell: 415 - 517 -4329; Grout Manufacturer: C -Cure; Grout Color: 25 White; Notes: Location: Storefront, NOT SIGNBAND, see plans. * * ** Wood Base: Painted MDF.........._....._.......__......._...._.... ............_.._.._........_.._ Size: 5/8" x 4" Color: Paint P -le Finish: Catalyzed water based epoxy Notes: Sales Floor * * ** WB -1 ❑ z -1 ❑ T -1 is for Fashion Lab. WORK SCOPE DESCRIPTION Paint: Sherwin Williams Color: SW 7075 Web Gray (Dark Gray) Finish: Satin Notes: Location: Exterior FS /SC Signband, See plans FS=FreeStander, SC Shopping Center Paint: Sherwin Williams Color: SW 7073 Network Gray ( Medium Gray) Finish: Satin Notes: Location: Exterior FS /SC Trim Base, Top and Bottom band /Quoins, See plans * * ** Paint: Sherwin Williams Color: SW 7071 Gray Screen ( Light Gray) Finish: Satin Notes: Location: Exterior FS /SC Wall, Fields, See plans Tile — Porcelain: Graniti Fandre; Product: Marmi, Pallisandro Color: Off- white; Size: 16 "x16 "x3/8" Contact: Ann Feirabend 913 - 485 -3295 (anngraniti ©aol.com) Grout Manufacturer: C -Cure; Grout Color: 25 White Notes: Location: Mall Entry floor tile, as required, see plans * * ** Multi-spec Paint: Airless by Zolatone Product: A2M- C1007; Color: Medium Gray with White specs; Contact: Denny Gragg 1- 800 -354 -7117 Notes: Interior Finish at storefront, NOT SIGNBAND. See plans. * * ** PHII HZ 3 - 06 - 07 r8 PSS Landlord Existin g Contractor Contractor DNA n n ❑ ❑ ❑ ❑ ❑ ❑ ❑ H ❑ u ❑ n ❑ ❑ ❑ n E 171 IZ n F z Section 17000 - ADDITIONAL PROJECT REQUIREMENTS NOT LISTED ABOVE: ® PSS CONTRACTOR ❑ LL CONTRACTOR ® WORK SCOPE CLARIFICATIONS: NONE R 7 SPECIAL SITE CONSIDERATIONS: * SEE COMMENTS BELOW* ALL BIDDING CONTRACTORS SHOULD GO TO SITE TO REVIEW AS IS AND DRAWINGS IF TIME PERMITS. 7 WORK SCOPE DESCRIPTION EXISTING CONDITIONS SPECIAL INSTRUCTIONS: NONE SPECIAL INSTRUCTIONS FOR STORE RELOCATIONS: NONE End of C -i Specifications PHII HZ 3 -06 -07 r8 Existing PSS Landlord DNA Contractor Contractor Do eiECEIVEr NOV 2 9 2007 PERMIT CENTE1 -, Project North R e v i s i o n s Date 11/27/07 Descrrptro i OWNER REVISION FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 KIRKLAND, WA 98033 8425.8272100 F:425.828.6899 \ , r 2 THOMA ED SPACER STATE OE WASFI; "JGTON STORE NO. 1723 SOUTHCENTER SQUARE 17250 SOUTHCENTER PARKWAY, SUITE 128 TUKWILA, WA SPECIFICATIONS DRAWN BY: CP DRAWING NAME: 07652A55.dwg DATE: 1 1/27/07 PROJECT NO.: A07 -652