Loading...
HomeMy WebLinkAboutPermit D07-451 - INTERNATIONAL GATEWAY WEST - MED DATA - TENANT IMPROVEMENTMED DATA 12101 TUKWILA INTERNATIONAL BL D07 -451 City -f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 0923049031 Permit Number: D07 -451 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Issue Date: 02/08/2008 Suite No: Permit Expires On: 08/06/2008 Tenant: Name: MED DATA Address: 12101 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 Phone: Contact Person: Name: NIXON GOLLA Address: 2221 5 AV , SEATTLE WA 98121 Phone: 206 441 -1449 Contractor: Name: WILCOX CONSTRUCTION INC Address: 123 4TH AVE N , EDMONDS, WA 98020 Phone: 425 774 -4185 Contractor License No: WILCOC*194Q0 Expiration Date: 12/10/2009 DESCRIPTION OF WORK: PARTIAL FLOOR TENANT IMPROVEMENT ON THE FIRST FLOOR OF AN EXISTING OFFICE SPACE. CONSISTS OF DEMOLITION AND CONSTRUCTION OF PARTITIONS, DOORS, RELITES, CEILINGS, AND OTHER FEATHERS. THERE IS NO STRUCTURAL OR CORE/SHELL WORK. Value of Construction: $80,000.00 Fees Collected: $1,750.83 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 0008 * *continued on next page ** doc: IBC-10 /06 D07 -451 Printed: 02 -08 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: I ► �� ��_: Date: I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pe 't. Date: O jl Signature: Print Name: doc: IBC - 10/06 N City c./ Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us fir Permit Number: D07 -451 Issue Date: 02/08/2008 Permit Expires On: 08/06/2008 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 -451 Printed: 02 -08 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 0923049031 Permit Number: D07 -451 Address: 12101 TUIKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 12/10/2007 Tenant: MED DATA Issue Date: 02/08/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. D07 -451 Printed: 02 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (ITC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 20: Minimum widths of corridors shall be maintained in accordance with Chapter 10 of the International Building Code and the International Fire Code. 21: In Group B and M occupancies, the minimum clear aisle width shall be determined by the occupant load served, but shall not be less than 36 inches. (IFC 1013.4.1) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (EEC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not doc: Cond -10/06 D07 -451 Printed: 02 -08 -2008 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3) 31: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 32: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 35: U.L. central station supervision is required. (City Ordinance #2050) 36: All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. (City Ordinance #2050) 37: All exterior components of sprinkler systems should be painted RED. This includes: Post indicator valves (PIV), outside stem and yoke (OSY), wall indicator valves (WIV), and Fire Department connection (FDC). (City Ordinance #2050) 38: Fire department connections (FDC's) shall be oriented in the direction of fire apparatus access, have a 4 foot clear space in front and to the sides of the connection, be appropriately signed and protected from potential vehicular damage. 39: The fire department connection (FDC) shall have a downward angle bend between 22.5 and 45 degrees, with a 5 -inch Storz fitting(s) and Knox FDC locking Storz cap. (NFPA 13- 6.8.3) (City Ordinance #2050) 40: The height of fire department connections (FDC's) shall be 36 to 48 inches above grade. 41: For all commercial, multifamily and single family subdivisions, hydrants shall be placed so that a hydrant is within 150 feet of a building and so that no point of a building (around its perimeter) is greater than 300 feet from a hydrant. Distance from a hydrant to a building is measured along the path of vehicular travel. (City Ordinance #2052) 42: An approved manual fire alarm system is required for this project. The fire alarm system shall meet the requirements of 007 -451 Printed: 02 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 43: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 44: Local U.L. central station supervision is required. (City Ordinance #2051) 45: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 46: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #2051) 47: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (4.4.1.4.2.1)) 48: In areas that are not continuously occupied, automatic smoke detection shall be provided at each fire control units) location to provide notification of fire at that location. (NFPA 72) 49: The reset code for the fire alarm panel or keypad shall be 1- 2- 3-4 -5. The reset code shall not be changed without approval of the Fire Marshal. The reset code should be permanently posted at the keypad. (City Ordinance #2051) 50: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 51: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 -575 -4407 for ordering information. 52: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 53: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 54: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110.26(A) thru F(2)) 55: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 56: Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. (IFC 605.3.1) 57: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 58: Fire doors, fire windows and fire dampers shall have a label or other identification showing the fire protection rating. Such label shall be approved and shall be permanently affixed. (IBC 715.3 Table 715.3, 715.4, 716.3.1 Table 716.3.1) 59: When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials doc: Cond -10/06 D07 -451 Printed: 02 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us shall meet the requirements of International Building Code 803. 60: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 61: When fire resistive floor or floor ceiling assemblies are required to prevent the vertical and horizontal spread of fire and smoke, the assembly shall be maintained. (IBC 712.4.2) 62: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 63: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 64: Every building shall be accessible to Fire Department apparatus by way of access roadways with all- weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' shall be provided width an approved turn- around area. Access shall be within 150' of all portions of the buildings. (City Ordinance #2047) 65: There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (IBC 315.2.4) 66: All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (IFC 503.1, 508.1) 67: Aboveground gas meters, regulators and piping exposed to vehicular damage due to proximity to alleys, driveways or parking areas shall be protected in an approved manner. (IFC Ch. 312, sec. 312.1 thru 312.3) 68: Combustible material shall not be stored in boiler rooms, mechanical rooms or electrical equipment rooms. (IFC 315.2.3) 69: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 70: To schedule all construction fire - related inspections send an e -mail to fireinsprequest ©ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 71: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 72: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D07 -451 Printed: 02 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: I , c Date: / C Print Name: j---4 I �° ■ ) doc: Cond - 10/06 007 -451 Printed: 02 -08 -2008 CITY OF TUI LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cimkwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: (3`13(7 cyz I Site Address: I'LIrl TU L. is >• �k t l S WWI? Floor: , uite Number: Tenant Name: ' MOP' VAZTA Property Owners Name: � G 4—A VI"3 Mailing Address: Ii 'CUK44\L\ 1 -1'“1L • SIX/2 , `fU I- v. , 1'4 ^ 6 r I 1 CONTACT PERSON - who do we contact when your permit is ready to be issued. Name: Day Telephone: 20 - LI-'i-M - I LI Mailing Address: /Z-2'..2-1 }� �r t S i�c� t I, i vc r7-1 f � I �� • City State Zip E -Mail Address: t7/ Vl/ �� Fax Number: �D ' �"I �� GENERAL CONTRACTOR INFORMATION • (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: LAX t Gni 174j 1'� 1�TGH - k� 'iz Dry Contact Person: � Day Telephone: E -Mail Address: l` 'I— I&&ZT&14\I-- . C-111j..'' 'ax Number: Contractor Registration Number: VII l. 4a ‘ ---- Mt Building Znit No. MechanicaI Permit No Plumbing/Gas Permit N f Public Works Permit No. Project No. For once use New Tenant: City State Mailing Address: � '51: S • t 1>M17 4 4 t 1'L C (WO State Zip LI-z� '774 f - . LHgv 2 5 7 7 2 I �-t -14x7 Expiration Date: I /Z1 J v ARCHITECT OF RECORD =, All plans must be wet stamped by Architect of Record Name: T>ci-v .vic 4 17�'S1 � 17U P J�'{�C.ikl -T � 1 , Mailing Address: Z15 D mil I D? -1• *T. , - W 5171 .--",14`C (I ) 14.71C Contact Person: - r 't]17+-4 2I -b1-4 E - Mail Address: S(:: & 171::› r14 ZG 4 I l -1 ❑ Yes City State Zip Day Telephone: 7--P LQ . n3 - 14100 Fax Number: WLf 3 1/) • negg ENGINEER OF RECORD – All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: QitApplications\Forms- Applications On Line '3 2006 - Permit Application :doe Revised: 9-2006 bit State R.No Zip Zip Page 1 of 6 Valuation of Project (contractor's bid price): $ C b bC) ' Existing Building Valuation: $ Scope of Work (please provide detailed information): 1 7 1 41411 ) 44 / J T ' ft1 ' 7 / 1 M '1A7'1 l- rti3 Gds � yr . j 7L I ?l 4 GwS� -Uc-,--Cl t7i3 0"-11..(1361 , fL 1z . 15 I-� �'t1z.1,t G- i U AL t 1A n7 Will there be new rack storage? ❑ Yes '®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in care Footage Below st Floor r Floor 3'd Floor Basement Accessory Structure *. Attached Garage Detached Garage, Attached Carport Detached Carport Covered be Uncovered Deck 1J / Interior Remodel Addition to Existing Structure 1117 Typo 1DI-4 Typo of Construction per Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: \Applications\Forms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Date Application Accepted: Q'Applications\Forms- Applications On Line0-2006- Permit Application.doc Revised: 9 -2006 bh PERMIT APPLICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building.and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 AUT 0 ZED AGENT: ill _U Signature: •h Date: x/07/77 Print Name: L 6rrt/t-"A Day Telephone: 2 n1-y' 4+1' 1441 I Mailing Address: l`i' ` /10 .1 4 AssL'L• 2221 V Ct<511 City State Zip X21 col 01— Date Application Expires: Staff Initial Page 6 of 6 Receipt No.: R08 -00371 Initials: JEM User ID: 1165 Payee: MED DATA ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0923049031 Permit Number: D07 -451 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 12/10/2007 Applicant: MED DATA Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 75248 1,062.88 BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 Account Code Current Pmts Payment Amount: $1,062.88 Payment Date: 02/08/2008 04:19 PM Balance: $0.00 1,058.38 4.50 Total: $1,062.88 8410 02/11 9710 TOTAL 1062.88 doe: Receiot -06 Printed: 02 -08 -2008 City of Tukwila Parcel No.: 0923049031 Permit Number: D07 -451 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 12/10/2007 Applicant: MED DATA Issue Date: Receipt No.: R07 -02707 Payment Amount: $687.95 Initials: JEM Payment Date: 12/10/2007 08:37 AM User ID: 1165 Balance: $1,062.88 Payee: MARVIN STEIN & ASSOCIATES, LLC see TRANSACTION LIST: Type Method Description Amount Payment Check 26125 687.95 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 687.95 Total: $687.95 5844 12/10 9710 TOTAL 687.95 don! Rnmint -OR PrintAd: 19- 10- 9007 Project: j Type n� ion: Addr ss: / :1 01 TL. Date Called: Special Instructions: Date W�ed;l Z /D � // II � . m . Requester: Phone No 2 - 3)3- 2C 5 D 6 7 -L( INSPECTION RECORD Retain a copy with permit INSPECT NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 roved per applicable codes. El Corrections required prior to approval. COMMENTS: specto .S E $ • I. to REINSPECTION FEE REQU ' ED. P Ior to insp4ction ffee must be p d at 6300 Southcenter Blvd., Sui 10 Call to schedule reinspection. 'Receipt No.: !Date: Date: COMMENTS: __------ Type of Inspectipn: B 1 t h 1 J--) C /OA 1 alit 01)/— jtl 41, J 7` &, ( Z-4, /' J !.1 t /tike./1A - pu : ( M 0 0022 ft S (--) i--14 ova - F A 1 (e %.& Ql A45 S i .s S v e tnit\A Io c eA ,r' , 4a _i ,U AA A ;F / A e Jk W. (cam - co Al p 1 br ,xe 1 r-' - A 1m 1.-43 A' e prJ t ? p 7 I i Project: Type of Inspectipn: B 1 t h 1 Ad� Date Called: rimes 6 ( L Special Instructions: Date Wanted: a,in.- (I ' CO ' D Y p.m. Requester: Phone No: _ Z 1 7 _(003 k Retain a copy w p CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1218)431 -3670 Approved per applicable codes. 'Inspector: U $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: DD's -4J 1 INSPECTION RECORD ith ermit INSPECTION NO. PERMIT NO. El Corrections required prior to approval. 'Date: 1 / 1 tD Eg( INSPECTION RECORD Retain a copy with permit PERMIT NO. IL- INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: (Inspect n ►f fDate: (c_ Type opnspecti () u ., ` 0"-Ar Proje t: Address: (2(v l T,17. 8 . Date Called: --1 Special Instructions: Date Wanted: /- 141.111... ()Y P.m. Requester: Phone No. — 2,C ( 5 INSPECTION RECORD Retain a copy with permit PERMIT NO. IL- INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: (Inspect n ►f fDate: (c_ COMMENTS: - 0 S L,-te____ t k\, s 'Lk_ pe-a ,) ‘(__, re ne i Ar-r tve.A-1 mr6 `,\ UT-,e7 Address: 2 . ` ( - L Dat�Called: / Special Instructions: Date Wanted: 6- - 'o - De)/ .a.m. p.m. Requester: Phone 2 ( 40 T5 t E _ Projec /n1 J' 0 / t�' Type of Inspection: Y !� P� C r / Address: 2 . ` ( - L Dat�Called: / Special Instructions: Date Wanted: 6- - 'o - De)/ .a.m. p.m. Requester: Phone 2 ( 40 T5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. i 1 lnsPec1jr: D a 9 -45( Date El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: f n ap {IUD► -^ E%CJy '. R D t i G n c1 � ► t� �! el �P 7 s o f - s -z`' o -- -�s�P - zr Ai Address: .�� I ZwI t✓k tinit°1 Date Called: 3(jc i tJ 0,-if = p 4..._ S 9e e tY 1 C.0 &Try f' S L k-( I S k., k ) T A ppf f k. 6 ifY (1( „-Si U! S /V P ACC' e-r) ) ( e) t i r ` o - !, ' pp Jr Requester: Phone -265S Project: ittc_A DA-1A Type of Inspectio C (` Address: .�� I ZwI t✓k tinit°1 Date Called: 3(jc i Special Instructions: / Date Wanted: 3 -2 ? v- a.m. Requester: Phone -265S PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit £[) 7 -45 ( El Corrections required prior to approval. Inspect A ,I o M Date: 3 _ 9 _4 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: !Date: Project: inFi 3414 Type of Inspection: ..5 / PPn/LFD �fr ,u S Address: i /2 /0 t 7 3 -pku Date Called: A ,),,A P N J Ai ._. k ...,- 4 ; Special Instructions: Date Wanted: C a.m.' 3 Z S -p 7 p.m. Requester: Phone No: was 3i3 - 2 6gC INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE_I�1IT NO. CITY OF TUKWILA BUILDING DIVISION � 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. COMMENTS: iLeJ (9J F r Inspect Date:3 �5 ..- v c; (S 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: 1)6 7 -95 / Corrections required prior to approval. Project: )Y1f D 0.}"li) Type of Inspection: SLis PraLvo e`'e //' '5 Address: /ca. Aa/ Ti 6 Date Called: Special Instructions: Date Wanted: ?— 2./-0e.._ a.m. nr Requester: Phone No: aoG -3 /3-Z55 INSPECTION RECORD Retain a copy with permit INSPECTION NO. ; . PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'A 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. COMMENTS: Flee fr. ff r , I" , e it !14 4 /ff /ot /I Inspector: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Do7 -4 ) Corrections required prior to approval. 1 Date: 3 -. 2. 1.- -c' Project; 1 e l ,Z.)4 / Type of Inspection: 7 /A/ G Address: /' / /� V ( �1 //�'d' L 4 - - AA/ Date Called: . Special Instructions: Date Wanted: 3 / -O (.....- a.m. CFI: Requester: Phone 6 -.P3-2-6'5 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (Inspector: (O'7- 4 / 5 / PERMIT NO. (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS 6 /4 - z;hS (Date: -3 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: ---- -- _ Project: /22c /7,1 7s Type of Inspection: -....... Address: /2. / �' / 2//e4//2-4_2 Date Called: — Special Instructions: / Date Wan zo/o--. P.m. Requester: Phone No: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit I 1D67- - e7_57 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- OO r Blvd.. #100, Tukwila, WA 98188 (206)431- Corrections required prior to approval. COMMENTS: 'APO JAI 4kA Date: d El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 1 Receipt No.: 'Date: - Project: gr Type of Inspection: c-.....". L`t Address: 1210 I I \ Q Suite #: 1 )0o ` Contact Person: 14 Special Instructions: Phone No.: Needs Shift Inspecction: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: I Inspector: INSPECTION NUMBER CITY" OF TUKWILA FIRE DEPARTMENT 206 - 575 -4407 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit COMMENTS: — D /L_ UJa / / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. ord/Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS Corrections required prior to approval. T.F.D. Form F.P. 113 Project: m Ef O 374 Type of Inspection: ,Erk, c%rn '_`/ 14 'id; ;15 Address: 12ry I Suite #: TZ/3 Contact Person: // /14Y1 Special Instructions: Monitor: Phone No.: .2c. c/27 60.3. Needs Shift Inspection: -- - Sprinklers: Fire Alarm: t Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type :, 2 n Approved per applicable codes. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word/Inspection Record Form.Doc 1/13/06 `Oo7 — '/ 5 / PERMIT NUMBERS Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: s , 2 17 e7 fr 4 L2_ 1 s Inspector: 4 j Date: i ap/1 2 Hrs.: $80.06 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: m DA - Sprinklers: Type of Inspection: L. LT Address: J. I o' - 1 - 1 Suite #: p 0 0 Co tact Person: i Ot Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: n Approved per applicable codes. Inspector: INSPECTION NUMBER /OA 4 Word/Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT kwila, Wa. 98188 206 - 575 -4407 COMMENTS: 1\1 l o 10 A (u E-t T Dip 00 - t - 1 Fi / c D •1 Date: N/097 PERMIT NUMBERS rrections required prior to approval. Hrs.: / $8 .00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 T.F.D. Form F.P. 113 Project: Me D J4 1 Type of Inspection: Address: /2 / Di Suite #: 7"/ 6 Contact Person: C , iv ie , Special Instructions: Permits: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood , & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 F - Approved per applicable codes. COMMENTS: c Az ,47e.v+ 16 -- D /� Pai Ala tLW_ OfL- $80:60 REINSPECTION FEE REQUIRED. You will receive an invoice from e Cite Oukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT I u /5/2- I Date: ) Z /05 1/13/06 c ?- 2 - PERMIT NUMBERS n Corrections required prior to approval. T.F.D. Form F.P. 113 Project: V\ Type of Inspection: S ?,2_ ►►ai L i - C _- Address: 12 1 6 t T1 Suite #: Contact Person: - -- ,e,A Moolie-n Special Instructions: Phone No.: 2 2- -n - ( Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: COMMENTS: Inspector: .1,30,1,1L, ►_ Date: 3 /2- 6. /00 Hrs.: INSPECTION NUMBER 0 1( per applicable codes. • Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 t)R ^5- QS-9- PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 1 - 1 Corrections Kequired prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 07 -29 -2008 NIXON GOLLA 2221 5 AV SEATTLE WA 98121 Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, xc: Ter Marshall t Technician Permit File No. D07 -451 Cizy of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. D07 -451 12101 TUKVVILA INTERNATIONAL BL TUKW In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be In withine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 09/23/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 January 14, 2008 Allen Johannessen, Plans Examiner City of Tukwila — Building Services 6300 Southcenter Blvd, Suite 100 Seattle, WA 98188 Re: CORRECTION LETTER #1 Development Permit Application Number D07 -451 Med Data —12101 Tukwila International BI Dear Mr. Johannessen, This is in response to the correction letter you sent Marvin Stein and Associates (MSA) dated January 2, 2008. Please use this letter in conjunction with the revised drawings, Revision #1, dated January 11, 2008. Below is the additional information you have requested: 1. Names of spaces within the tenant's suite have been added on sheet TI -3. Tenant names on the third floor and their respective square footages have been added on sheet TI -1 at cell 1. 2. For occupant loads of the tenant spaces, please see cell 1 on sheet TI -1. 2. The path of egress travel is located at cell 1 on sheet TI -1. Pathway lighting is located on the reflected ceiling plan which is on sheet TI -4. Please see also cell 8 on sheet TI -1 for legend and notes regarding emergency lighting. Sincerely, • Nixon lla MAR STEIN & ASSOCIATES, LLC Marvin Ste Associates, c planning - I' design 1)p7- 451 Enclosures: Revision 1 — General Revision Per City Comments, 01/11/08. Completed Revision Submittal Form Cc: Admin 2221 Fifth Avenue Seattle, Washington 98121 (206) 441 -1449 Fax (206) 441 -4361 Email: marvinstein @isomedia.com CORER r: c . noN LTR# RECERTE) JAN 14 2008 PERMIT CENTER January 2, 2008 Nixon Golla 2221 5 Ave Seattle WA 98121 Dear Mr. Golla, Sincerely, Bill Rambo Permit Technician end File No. D07 -451 P:\Pennit Center\Correction Letters \20071D07 -451 Correction Ltr #1.DOC wer City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number D07 -451 Med Data —12101 Tukwila International BI This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. .z 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: December 20, 2007 Project Name: Med Data Permit #: D07 -451 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please name all spaces and adjacent suites or tenant spaces. Provide the square footage for each tenant space. 2. Show the total occupant load for the tenant spaces. 3. Identify egress paths and pathway lighting including all recommended emergency lighting for this tenant. Show adequate emergency lighting spaced apart to meet the illumination level required per code. (IBC 1006.1, 1006.2, & 1006.3) Should there be questions concerning the above requirements, contact the Building Division at 206 - 431- 3670. No further comments at this time. ACTIVITY NUMBER: D07 -451 DATE: 01 - -08 PROJECT NAME: MED DATA SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL _ Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: (Ct B I •O g Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Please Route Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: Fire Prevention Incomplete Structural Review Required Planning Division DUE DATE: 01 -17 -08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 02 -14 -08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPART ENTS• Buil;!ing !!vision Public 8 Wp (,1 J ACTIVITY NUMBER: D07 -451 DATE: 12 -10 -07 PROJECT NAME: MED DATA SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: 'PERMIT COORD COPY '' Structural Incomplete ❑ Structural Review Required 5(1 /W u iL. o1 Fire Prevention LISJ fibs. l2 - //-° Planning Division ❑ Permit Coordinator No further Review Required DATE: DATE: C DUE DATE: 12-11-07 Not Applicable n P DUE DATE: 01-08-08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Er Fire ❑ Ping ❑ PW ❑ Staff Initials: `k Yg- City of Tukwila REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: . u 1 12Gt Plan Check/Permit Number: D07 -451 ❑ Response to Incomplete Letter # ▪ Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Med Data Project Address: 12101 Tukwila International B1 Contact Person: Summary of Revision: Iz l l s1170 ��l.t r31'q r'`'T �� - �1 I t4 t`� I - �7 -�'S t' F1Z. ALL-P-0 2t:;177. s $4440M1 - -rii Gr (. 'i't's- CCg- 1t* (71° Sheet Number(s): i a . \11 �✓ lt 7 r ' $W C ZU t* 14317 1 i LDG 'S fij t70 5► -r 'C� - l , 1 -3 4- T1-11-. "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: rgr Entered in Permits Plus on l 1 -69) \applications\forms - applications on line\revision submittal Created: 8 -13 -2004 R evicerl• Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Nixon Golla Phone Number: 2D1� LI44-I . ► y�-1-LI Steven M. Mullet, Mayor Steve Lancaster, Director CITY OF RECEIVED 'JAN 14 2008 REFitoir caNTEH License Information License WILCOC• 194Q0 Licensee Name WILCOX CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 319007592 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 234 5T1I AVE SOUTH Address 2 11/21/2005 City EDMONDS County SNOHOMISH State WA Zip 98020 Phone 4257744185 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/20/1981 Expiration Date 12/10/2009 Suspend Date Separation Date Parent Company Previous License WILCOAE376NO Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WILCOX, ROBERT EUGENE PRESIDENT 11/20/1981 LESSARD, MATTHEW J SECRETARY 11/21/2005 LESSARD, JAMES MICHAEL VICE PRESIDENT 11/20/1981 11/21/2005 WILCOX, A E 01/01/1980 01/01/1980 WILCOX, LAURA 01/01/1980 01/01/1980 OLDS, HOWARD A SECRETARY 01/01/1980 01/01/1980 Look Up a Contractor, Electri"tan or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WILCOC* 194Q0 02/08/2008 ACT ACOUSTICAL CEILING TILE LL @TE BY LANDLORD AT TENANT'S EXPENSE ADJ ADJACENT /ADJUSTABLE LF LINEAL FOOT AFF ABOVE FINISH FLOOR MAX MAXIMUM ALT ALTERNATE MECH MECHANICAL ALUM ALUMINUM MFR MANUFACTURER APPROX APPROXIMATELY MIN MINIMUM AT M15C MISCELLANEOUS BLDG BUILDING MTD MOUNTED BLKG BLOCKING MTL METAL BUDING STANDARD M W M ICROWVE OVEN CAB CABINET ORTH, EW CLEARAiJCE NIA NOT APPLICABLE CLG CEILING NIC NOT IN CONTRACT CL CENTERLINE NO NUMBER COMM COL COLUMN NOM NOMINAL COMMUNICATION NTS NOT TO SCALE COMP COMPOSITION OC ON CENTER CONST CONSTRUCTION OPNG OPENING CONT CONTINUOUS OPP OPPOSITE CPT CARPET ORIG ORIGINAL CT CERAMIC OR CONCRETE TILE PERM PERMANENT DIA DIAMETER PL PLATE DIM DIMENSION PLAM PLASTIC LAMINATE DR DOOR PLY WD PLYWOOD DW DISHWASHER PR PAIR pWG PTR PARTITION DRAWING E EXISTING, EAST R RADIUS, REMOVE, RELOCATE EA EACH RB RUBBER BASE ELEC ELECTRIC REF REFRIGERATOR ELEC'L ELECTRICAL REINF REINFORCING ELEV ELEVATION (VIEW) REQ D REQUIRED ± EXIST EXISTING REV REVISION /REVERSE EXT EXTERIOR RM ROOM ROUGH OPENING fi FIN FINISH RO R i FLR FLOOR S SOUTH r FLUOR FLUORESCENT SCHED SCHEDULE SC SOLID CORE FR FIRE RATED SECT SECTION FT FEET FURN FURNISH /FURNISHINGS 51M SIMILAR GA GAUGE SPEC SPECIFICATION GALV GALVANIZED SQ SQUARE GD GARBAGE DISPOSAL STD STANDARD GL GLASS/GLAZING STL STEEL GWB GYPSUM WA LL BOARD STOR STORAGE 4' HC HOLLOW CORE SUSP SUSPENDED HDW HARDWARE TEL TELEPHONE ,; HM HOLLOW METAL TYP TYPICAL rc H7 HEIGHT UNO UNLES NOT OTHERWISE HVAC HEATING, VENTILATING, VCT VINYL COMPOSITION TILE AIR CONDITIONING VERT VERTICAL IN INCH W WEST INCL INCLUDE W/ WITH W/0 WITHOUT INSUL INSULATION WC WALLCOVERING INT INTERIOR JT JOINT WD WOOD WSBF WASHINGTON STATE BARRIER FREE AREAS OF WORK SCOPE OF WORK: PARTIAL FLOOR TENANT IMPROVEMENT ON THE THIRD FLOOR OF AN EXISTING OFFICE SPACE. I NTE RGATE WEST C TU K WI LA INTERNATIONAL BLVD. TUKWILA , WASHINGTON 98168 ii /� �i�� COPY Permit Nor 1 Pla review approval is subject to errors and r' oni ons. Approval of constr documents does not authorize the violation of an adopted opted cads or or+dilrtanc@. Rece6pt of approved Field Co and moons Is acknowledged �� Copy PATH OF EGRESS 4 1\ TRAVEL IS LESS _ ,k �I �`� \ :: ; , , ' ��' ........ THE WORK CONSISTS OF DEMOLITION AND CONSTRUCTION OF PARTITIONS, DOORS, RECITES, CEILINGS, AND OTHER FEATURES. THERE IS NO STRUCTURAL OR CORE AND SHELL WORK. PROJECT ADDRESS: INTERGATE WEST - BUILDING C THAN 100' 4 ' w I � .. ` :::: ' : •• ;•; � -: ; : ; ; ' . . •; • M \\• ME DATA B ��ra�aaY MED DATA "A" " i I .... ..... .. ............ .. ... .. ........ .: : . ::: :: ' : ........... .... ................. • -- ` "�� I i ` 4 1; 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 PARCEL NUMBER: 092304 9309 OCCUPANT LOAD CALCS.: I � , I I = = ='� =7�1 `1 L =� .; � P `� i M C d l),e , wll�i� : , � I ; ® X 9 1 ® , dsi � ° 1' tl �' � ��� 7:1,1'7 oBeY u ,Is h pt'. 1._ 1 1 .1 __ :.1 I__ : I� i<< � „ „ MED DATA A r i � fir.. a e�.r Ni i LEGAL DESCRIPTION: BEGINNIN ON THE SOUTH LINE OF THE NORTHEAST 1/4 OF THE SOUTHEAST 1/4 OF SECTION 9 Ik 5,899 US F 2 ERUIRED2 @ 1:100 = 59 OCCUPANTS ETS PROVIDED m � ) I!In film, .� li yi N � - II, 0 _jw �dl ld ;_ ( I -►y.i _ • , :1..�. THENCE EAST 150 FEET TO SAID WEST MARGIN, THENCE NORTHWESTERLY ALONG SAID WEST , , , MARGIN TO A POINT 60 FEET NORTH OF MEASURED AT RIGHT ANGLES TO SAID SOUTH LINE 12101 CONTINUING NORTHWESTERLY ALONG SAID MARGIN 60 FEET; THENCE SOUTHWESTERLY TO THE TRUE POINT OF BEGINNING, ALSO BEGINNING AT THE NORTHWEST CORN OF THE PARCEL LAST ABOVE DESCRIBED THEN EAST PARALLEL WITH THE SOUTH LINE OF SAID SUBDIVISION TO THE CENTERLINE OF STATE HIGHWAY N01, THENCE NORTHWESTERLY ALONG SAID CENTERLINE 380 FEET, THENCE WEST PARALLEL WITH SAID SOUTH LINE TO A POINT 150 FEET WEST OF THE WEST MARGIN OF STATE HIGHWAY NO 1, THENCE SOUTHEASTERLY TO THE POINT OF BEGINNING, EXCEPT THAT PORTION THEREOF T E HIGHWAY NO ITUATE IN THE CITY OF TUKWI OUNTY 0 KIN TATE 1S LAC GS OFWASHINGTON . ZONING: C /LI s ',, „ki,ry f x �,., 7y_ ,d ,r s� an,.., r ;^- � �, h, - l . �� ru k - , . ® �.,) . I BUILDING I .,r� ,1 . t . _ .. .. �, J - - r ` J -_ - EXIT . . ,.:,, : ... \ \ \ '� �� MED DATA B I ��� III _ EXIT - 2,293 USF @ 1:100 = 22.93 OCCUPANTS 1 EXIT REQUIRED, 1 EXIT PROVIDED _ T _ ^_ ^ _- ..................:THENCE ,, . , .............. .. � • �� • • . • • • . ; ( , • ::: _ _ _ w � I �� I �� 'r r � `�., , 1 _ .� \ o / ` , , �I � I• I . • . • . .. .. ... . • • • • • • • • I' •' •'•'•'•'•' •'•'• '.' •'.'.'.'.'.'.'.'..'............ 0 ... • ... • • • . • • • .• • • . • • •• .�•t�.'• . • .. • .....• .� ....... .......tt.;...;......... d. o, ;, FSMD (SUBTENANT) 6,189 USF @ 1:100 = 61.89 OCCUPANTS 2 EXITS REQUIRED, 2 EXITS PROVIDED • ... _ � /�. / �� . I DEC% - � , Al , � -; ..� ` � I Alf II J I I, �I I • .. FSM .. ... .... ..... . ..... ... ..... .. ..... ..• ..•... �: A. TYPE OF CONSTRUCTION: II, SPRINKLERED, QUICK RELEASE SPRINKLER HEADS (IN ACCORDANCE WITH N.F.P.A. 13 AND ..- . � _..- �.- �' i �� SECTIONS 903.3.1.1 & 903.3.2). OCCUPANCY: B (OFFICE) � - --- - - - - -- - _ - - - -- y EXITS SEPARATION IV EXITS SEPARATION R LONGEST DIAGONAL ` LONGEST DIAGONAL KEY I EXITING PLAN AND OCCUPANT LOAD CALCULATION 1' = :1 _ _ r i°"hii ' TE PERMIT ~ AREA OF WORK: APPROXIMATELY 5,899 SF �� a i; s 2 y7 BY BUILDING CODE: IBC, 2006 EDITION I��C�UII ED FOR: ,� r / eci lanical � �,! ectricdl ( �E IUntbin g i Gas Piping City Of TL1kWila al ©iV a�9a0`�1 'S r '2 ..........:.. .... .... _ ...... _..... \ �, `r I .r fir FIRE CODE: IFC, 2006 EDITION I C of Tukwila DIVISION . rr £ a - ��z: ;t y ` ) ` NOTE: �!-� and may ,nclu additional oars F . - x PLUMBING CODE: UPC, 2006 EDITION ENERGY CODE: WASHINGTON STATE ENERGY CODE, 2006 EDITION •�- ^ + G _• \ w A 3 T C � � \ \Z�: ' .• •� � \ A + , y = 1► \ 0 2 \ a F, \ I' I i ; 51 1BT II ST ' ' a � = a s � z m =; BARRIER -FREE CODE. AMERICAN NATIONAL STANDARD ICC I ANSI A117.1, 2003 EDIT JI TENANT MED DATA 9709 THIRD AVENUE NE, SUITE 301, SEATTLE, WA 98115 206 529 9742 (P), 206 529 9663 (F) EMAIL: jefllo @meddata.com ;r CONTACT: JEFF LONEY BUILDING SABEY CORPORATION y 599 ° 5` REPRESENTATIVE: 12201 TUKWILA INTERNATIONAL BLVD, 4TH FLR, TUKWILA, WA 98168 � _ Marvin Ste V ' r so c i at es LLC planning design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 i� 206- 281- 8700(P),206 -282 -9951 (F) EMAIL: marcyj @sabey.com Y CONTACT: MARCY JENKINS SPACE PLANNER: MARVIN STEIN AND ASSOCIATES, LLC IN TERGATE WEST \ 3 "� BUILDING C �' �3 7- o >' -..,. 62 I 12101 TUKWILA INTERNATIONAL BLVD \,- r \ TUKWILA, WA 98169 50 ' 2221 5TH AVENUE, SEATTLE, WA 98121 t a„' 206-441-1449 (P), 2064-41-4361 (F) _ @ EMAIL: s.navarro@marvinstein.com T CONTACT: STEVE NAVARRO s ' GENERAL TBD y NOTE: 1. THIS IS NOT A REPRESENTATION OF A LEGAL SURVEY. \ A INTERG WEST �'� BUILDING C y 12101 TUKWILA INTERNATIONAL BLVD y� TUKWILA, WA 98169 CP CONTRACTOR: EMAIL: , CONTACT: 5 - Milli- NORTH 2 ABBREVIATIONS 3 1 SITE MAP NTS DOOR NUMBER TYPE OF DOOR 4 VICINITY MAP NTS EXISTING CONSTRUCTION TO REMAIN 5 PROJECT INFORMATION 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS & SPECIFICATIONS FOR BUILDING. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. 5. DIMENSIONS TO AND OF ELECTRICAL & TELEPHONE OUTLETS INDICATES MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 6. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS, UNLESS NOTED OTHERWISE. 7. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS WHERE APPLICABLE. 8. CONTRACTOR TO PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 9. CONTRACTOR SHALL ALIGN OR FURR ALL INTERIOR PARTITITONS SO THAT FINISHES REMAIN FLUSH IN ROOMS AND CORRIDORS REGARDLESS OF DIFFERENCES IN PARTITION WIDTHS. 10. CONTRACTOR TO PROVIDE LEVELING THROUGHOUT THE SPACE FOR PROPER INSTALLATION OF EQUIPMENT, PARTITIONS, DOORS, GLUE -DOWN CARPET, ETC, TOLERANCE OF 1/4" IN 10' -0" DIFFERENCE IS ACCEPTABLE. DRAWN BY NG, SH JOB NO 07000.001 CHECKED BY: SN DATE: ' 12/4/07 EXISTING B/S ACOUSTICAL CEILING TILE AND TRACK TO REMAIN. NEW B/S ACOUSTICAL CEILING TILE AND TRACK AT 7' -10" AFF. -k rt PERMIT SET SCALE: AS NOTED = _ _ = EXISTING CONSTRUCTION TO BE DEMOLISHED EXISTING FULL HEIGHT RELITE TO REMAIN. REVISIONS/ISSUANCE: i► A. NEW B/S 3' -0" WIDE x 7' -0" HIGH S.C. MAPLE WOOD DOOR WITH B/S STEEL FRAME. = NO. REVISIONS INDICATED THUS A \ DATE � j � EXISTING PARTIAL HEIGHT RELITE TO REMAIN. = NEW STANDARD TENANT PARTITION 'A'. SEE DETAIL 1I1 -2. . I EXISTING PENDANT LIGHT FIXTURES TO REMAIN. C = = = = D EXISTING PENDANT LIGHT FIXTURES TO BE REMOVED. IIIII EXISTING PENDANT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING, IF NEEDED. EMERGENCY LIGHTING LAYOUT IS CONCEPTUAL ONLY. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING DESIGN. ® NEW B/S 1'x8' PENDANT LIGHT FIXTURE FOR EMERGENCY LIGHTING. EMERGENCY LIGHTING LAYOUT IS CONCEPTUAL ONLY. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING DESIGN. /\ GENERAL REVISION PER CITY COMMENTS 01/11/08 HARDWARE 'B'. = = NEW STANDARD TENANT PARTITION SEE DETAIL 21TI -2. NEW FULL HEIGHT RELITE: 3' -0" WIDE IN B/S MAPLE FRAME WITH SAFETY GLASS WHERE REQUIRED. HEIGHT 8" UNLESS a. B/S LOCKSET OTHERWISE NOTED b. B/S LATCHSET. rcz TO MATCH THAT OF DOOR FRAMES. NEW B/S DEMISING PARTITION AT HEADER. SEE DETAIL 3/TI -2. FULL HEIGHT DEMISING PARTITION. SEE DETAIL 4/TI _ I I EXISTING B/S 2'x4' FLUORESCENT LIGHT FIXTURE TO REMAIN. = NEW B/S -2. ! _ L � NEW B/S 2'x4' FLUORESCENT LIGHT FIXTURE. I • 0 EXISTING DOOR T 0 REMAIN. NEW B/S FULL HEIGHT PARTITION WALL TO MATCH EXISTING. NOTES: NEW B/S 2'x4' FLUORESCENT LIGHT FIXTURE FOR EMERGENCY LIGHTING. SEE EMERGENCY LIGHTING NOTE ABOVE FOR MORE INFORMATION. 0 EXISTING, U.N.O., B/S EXIT SIGN. (DIRECTIONAL WHERE SHOWN). REUSE EXISTING EXIT SIGNS WHENEVER POSSIBLE. (N = NEW) EXISTING, U.N.O., B/S WALL LIGHT SWITCH (N = NEW). ! ! ALIGN \ NOTES: CONSTRUCTION LEGEND NTS 7 GENERAL NOTES NA 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. �• 2 :� CONTRACTOR SHALL PROVIDE EM PATHWAY LIGHTING. THE MEANS pF EGR.ESS SHALLNOT Be zv_ESS THAN 1`FOOT "CANDLE (11 LUX) THE FLOOR LEVEL. , 3. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRENT CODES AS NECESSARY. 4. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. 5. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 7. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AREAS AS DEFINED IN CHAPTER 12,`BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 8. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 9. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. I 0 EXISTING, U.N.O., B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET EXISTING, U.N.O., B/S WALL MOUNTED VOICE/DATA OUTLET EXISTING, U.N.O., BLANK FACE PLATE ® EXISTING POWER POLE "N" NEW TO MATCH EXISTING B/S NOTES: TI -I COVER SHEET AND NOTES TI -2 NOTES AND DETAILS TI -3 DEMOLITION/ CONSTRUCTION PLAN TI -5 ELECTRICAL/ COMMUNICATIONS PLAN TENANT: MED DATA EXPANSION 'C E°R E C [ °'� ION . .TR.# - I: - = • " , a ' 5 '- JAN 14 2008 E . €"" CENTER PEn"i; 1(I CE _ 1. ALL NEW HARDWARE TO MEET ALL APPLICABLE LAWS, CODES AND STANDARDS FOR BARRIER FREE COMPLIANCE. 2. KEYING FUNCTIONS TO BE COORDINATED BY TENANT. 3. RE -USE EXISTING DOORS SCHEDULED FOR REMOVAL WHEREVER POSSIBLE. DOORS TO BE RE -USED ARE TO BE TOUCHED UP TO BRING INTO "LIKE NEW" CONDITION. 4. PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. ACCESSIBILITY NOTES: 1. ICC /ANSI A117.1 -2003 SECTION 404.2.4. DOOR THRESHOLDS: THRESHOLDS AT DOORWAYS SHALL BE 1/2 INCH MAXIMUM IN HEIGHT. 2. ICC/ANSI A117.1-2003 SECTION 404.2.6. DOOR HARDWARE: HANDLES, PULLS, LATCH, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR. 3. 404.2.5 DOOR OPENING FORCE: FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: a. INTERIOR HINGED DOOR: 5.0 POUND (22.2 N.) b. SLIDING OR FOLDING DOOR: 5.0 POUND (22.2 N.) THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD DOOR IN A CLOSED POSITION. SHEET TITLE: THIRD FLOOR COVER S H E ET AND NOTES li `,. 1, ( 1. ALL OUTLETS TO BE MOUNTED 15" A.F.F. TO BOTTOM OF OUTLET PER W.S.B.F. REQUIREMENTS U.N.O. 2. ALL COMMUNICATIONS (VOICE / DATA) LINES TO BE ROUGH IN ONLY (MUD RING W/ PULL WIRE). REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A Ti.i 8 I CEILING LEGEND & NOTES NA 9 I DOOR SCHEDULE NA 10 I ELECTRICAL LEGEND & NOTES NA 11 DRAWING INDEX s ATION FEDERAL COPYRIGHT LAW. COPYRIGHT BY OF 5 L CL on o C 0 C S 0 G 0 C C C- w C a au 0 C C J C7 cn J C iJ II ¢ cr)Q C c � 0 r� E Dl O C 0 C-0 CO a' o a METAL STUDS STAGGERED @ 8' -0" O.C. POWER DRIVEN FASTENERS SEE DETAIL 8/TI -2 ABOVE. TNG A CG O U S TICAL CEILING 8 " Vj // v INTERGATE W EST BUILDING C 12101 TU K WI LA INTERNATIONAL BLVD. TUKWILA, WASHINGTON 98168 !' r: 1 << A r SEISMIC BRACING PER 2/TI + 8' -0" A.F.F. -2. � @ - 11 EXISTING HEADER � EXISTING STRUCTURE ABOVE. CONT. 20 GA. GALV. STEEL TRACK ANCHOR TO STRUCTURE AS REQ'D, WITH APPROPRIATE POWER DRIVEN FASTENERS. DEFLECTION TRACK. SEE DETAIL 9/TI-2. ALIGN WALL SURFACE WITH — SURFACE OF HEADER. �ti[ai[ia[a CONTINUOUS ACOUSTIC SEALANT. 1/4" NON COMB. WD FILLER UNDER MAIN � i i �1 TO _ RUNNER / CONTINUOUS CEILING GRID � .... [[R[ [[[[[[a BIS ACOUSTICAL CEILING TILE @ ± T-10", WHERE APPLIES. 5/8" NON PLYWOOD BLOCKING GWB TO EXTEND 3" PAST TOP - ' CEILING. - °: \ STRUCTURE AS REQ'D. WITH PPROPRIAOR POWER DRIVEN FASTENERS. _ DO NOT CUT. OF ACCOUSTICAL ))�)��)))�� NEW ACCOUSTICAL CEILING @ 7' - 10" A.F.F. DEFLECTION TRAC SEE DETAIL 9/1 �� WW. {I01Meritrlit LINE OF CEILING GRID BEYOND, SEE LINE OF COLUMN BEYOND. 1- REFLECTED CEILING PLAN I CONT. 'L' METAL TRIM W/ PAPER WING , IF J['] Rimini[ REVEAL (PAINT BLACK) 118" BLACK FOAM TAPE HOLD BACK 1l4" FROM EDGE OF TRACK GWB TO EXTEND 6" PAST TOP i EXISTING ACCOUSTICAL CEILING @ 8' - 11" A.F.F CONT. 21/2" x 1 114" 25 GA. TRACK W/ (2) #10 SCREWS @ 24" 0.C. 5/8" NON PLYWOOD BLOCKING @ • • 1 I -COMB. WALL HUNG ITEMS (WHERE APPLICABLE REFER TO DRAWING PLANS ) ALTERNATE #1 FOR BLOCKING: OF ACCOUSTICAL CEILING. f -COMB. @ WALL HUNG ITEMS HERE APPLICABLE - / REFER TO DRAWING PLANS) ALTERNATE #1 FOR BLOCKING: nIDIPIRI PROVIDE ACOUSTIC BAIT INSULATION BETWEEN STUDS. � " -------D PLYWOOD BLOCKING 20" WIDE GALV. SHEET METAL @ +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) HEAD SECTION 20" WIDE GALV. SHEET METAL @ +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) HEAD SECTION L- -- NEW ACCOUSTICAL CEILING ? �° T - 10" A.F.F. I' / 518" NON COMB. @ WALL HUNG ITEMS (WHERE APPLICABLE WALL REFER TO DRAWING PLANS). ALTERNATE #1 FOR BLOCKING: PROVIDE ACOUSTIC BATT INSULATION BETWEEN STUDS. 5/8" NON COMB. PLYWOOD BLOCKING , G----) '° JJJ 20" WIDE GALV. SHEET METAL @ +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING). LINE OF COLUMN BEYOND. BASE AS SCHEDULED Mk 1 518" GWB, TYPE'X' EACH SIDE, TYP. @ WALL HUNG ITEMS (WHERE APPLICABLE / f 11( I� 5/8 "GWB, TYPE EACH SIDE, TYP. CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. - / ' � , PLANS) REFER TO DRAWING PLANS ) %. ALTERNATE #1 FOR BLOCKING: A AL ALTERNATE #1 OR BASE, AS SCHD. EDULE T— WIDE B METAL @ +40" FROM �' FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) BLOCKING x:. _. ��'''' I I I 3 1/2 STEEL STUD 24" D.C. WITH 518" 1( � I —CANT. 25 GA. GAL STEEL RUNNER CHANNEL - ANCHOR TO FLOOR A5 REQ'D. BASE SECTION '. PP" I I @ TYPE 'X' GWB EACH SIDE BASE, A5 SCHEDULED. CONT. 20 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'b. BEYOND. 1 I I BASE AS SCHEDULED BASE SECTION _ ` 24" O.C. WITH 5/8" 3 /2" STEEL STUD Marvin ate ..socltes, LLC Tannin � desi n - g 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 - �� �. 1 111.7 41 I [ -1 @ TYPE'X' GWB EACH SIDE. BASE, AS SCHEDULED, •� — CONT. 20 GA. GALV. STEEL RUNNER C HANNEL ANCHOR TO FLOOR AS REQ'D. � �„ ` � �r�i LINE OF COLUMN � I � I� I f �> 2112" x 25 GA. GALV. STEEL STUD © 24" O.C. WITH 5/8" TYPE' X' GWB EACH SIDE. 2 112" x 25 GA. GALV. STEEL STUD @ 24" O.C. WITH 5/8" TYPE'X' GWB EACH SIDE. PLAN VIEW I r PLAN VIEW 1 � STANDARD TENANT PARTITION ' ' NTS A 2 STANDARD TENANT PARTITION 'B' NTS 3 DEMISING PARTITION AT HEADER NTS 4 FULL HEIGHT DEMISING PTN. NTS DRAWN BY: NG, SH JOB NO 07000.001 METAL STUDS STAGGERED 8' -0" NOTE: SUSPENDED CEILINGS ARE TO COMPLY W/ FOLLOWING CODES & REGULATIONS: HVAC: CHECKED BY: SN DATE: 12/4/07 PERMIT SET SCALE: AS NOTED 1. RECONFIGURE AS REQUIRED FOR ALTERATIONS. 2. REBALANCE HVAC SYSTEM. 3. CLEAN ALL EXISTING GRILLES. 4. VERIFY AND RELOCATE THERMOSTAT AS NECESSARY. FIRE LIFE SAFETY: t .- a I , 10 IL 111111111 II � liiii VERTICAL WIRE HANGER-NO. 12 GAUGE @ 4' -0" O.C. OR NO. 10 GAUGE @ 5-0" O.C. ALONG EACH RUNNER. I / HEAVY GAUGE WIRE "PIN ". 1. 2006 INTERNATIONAL BUILDING CODE (IBC) ( ) SECTIONS 803.9 AND 1621.1. 2. ASTM C635 AND ASTM C636 ( REFERENCED IN IBC ) 803.9. ASTM IS AN ACRONYM FOR AMERICAN SOCIETY FOR TESTING AND MATERIALS. 3. ASCE -7 SECTION 9.6.2.6 (REFERENCED IN IBC 1621.1.2). ASCE IS AN ACRONYM FOR AMERICAN SOCIETY OF CIVIL ENGINEERS. 4. CISCA RECOMMENDATIONS FOR SEISMIC ZONES 3 -4 (REFERENCED IN ASCE -7 SECTION 9.6.2.6.2.2). CISCA IS AN ACRONYM FOR CEILINGS & INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION. - REVISIONS ISSUANCE: #10 SCREWS @ O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' -0 ". ATTACH TO STRUCTURE ABOVE W/ POWER DRIVEN FASTENER 3/4" MIN. / NO. REVISIONS INDICATED THUS / \ A DATE COMPRESSIBLE SPRING LOADED VERTICAL STRUT @ 12' -O" EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE. (2) + 8' 0" A.F.F. _ 1. ALL FIRE EXTINGUISHERS, HORN STROBES, EXIT SIGNS AND SPRINKLER HEADS, ETC. TO BE PER CODE'S MOST RECENT REQUIREMENTS. " ". 45° 45° MAIN RUNNER AT 4' -0" O.C. rj r------'-1 r • 21/2" X 25 GA. STL. STUDS 24" O.C. @ W/ 5/8" GWB, TYPE 'X', EACH SIDE. F �: VERTICAL STRUT FASTENED TO MAIN ..11 Apr' RUNNER. CROSS RUNNER INSTALLATION 5 SUSPENDED CEILING NOTES 6 HVAC AND FIRE LIFE SAFETY NOTES LATERAL BRACING TENANT WALLS (NO CASEWORK) j f/" 25 GA. GALV. STEEL ANGLE FROM 10° MAX. 1 OF WIRE PLUMBLINE = 6 6 TENANT: M E D DATA EXPANSION JAN 1 4 2008 pp�� a (. N CC�� rEli, IP&ii'4lui INSTALL PER INTERNATIONAL BUILDING CODE SECTION 803.9.1.1. "SUSPENDED ACOUSTICAL CEILINGS ". SUSPENDED CEILING SUPPORT DATA 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 2' MAX / STUD @ 24" O.C. x x SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER 2003 IBC SECTION 803.9.1.1. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER 2003 IBC SECTION 803.9.1.1. DISCONTINUOUS ENDS OF CROSS- RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. NOTE: CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRENT CODES AS NECESSARY. I LATERAL BRACING PER tivra�rrw�w�w��,w�w�w�w�w� ` 4 LATERAL DETAIL ABOVE (TYP.) NOTES: � ATTACH TO STRUCTURE ABOVE WITH POWER , , ! #12 HANGER WIRE ANCHORED TO STRUCTURE ABOVE ACTUATED FASTENERS. FACE OF WALL USG 1" X 2" ANGLE OR APPROVED SEISMIC CLIPS W/ 1" k VERTICAL DEFLECTION SHEET TITLE: THIRD FLOOR NOTES AND DETAILS - ' " 1C) 0 STABILIZER BAR TO KEEP COMPONENTS FROM SPREADING APART ATTACHMENT USING VERTICLIP SLD SERIES BE TUO BY I 'THE AS STEEL TEEL NETWORK - 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (PER TYP. PART. PLAN) 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL NTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 3. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. UL 2079. CUT STUD SHORT @ `� O ` HEAD TO ALLOW FOR VERTICAL DEFLECTION 3/4" REQUIRED BY CODE RED 1 -1/4" PLAY (MARGIN OF ERROR) MAX 8" REQUIREMENTS. ' HEAVY DUTY CROSS TEE �---- REPRODUCTION, ALTERATION OR PUBUCATION OF THIS DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A T1.2 7 PARTITION HEAD BRACING DETAIL NTS 3 I SUSPENDED CEILING SUPPORT DATA NTS 9 DEFLECTION TRACK DETAILS NTS 1 9 PERIMETER SEISMIC DETAIL NTS MS &ATION FEDERAL COPYRIGHT LAW. COPYRIGHT BY OF 5 E Dl O C 0 C-0 CO a' o a E a) 0_ n cn C C 0 0 C D O w 0 v n n u a) 0 C CD n cn J CO cn n C.° CO cn co C o o (An m ii")II C ED r� hi (D. cn . ESSE ©rcr)c x EXISTING CONFERENCE EXTERIOR DECK EXISTING OFFICE EXISTING OPEN WORK AREA EXISTING SERVER ROOM OPEN WORK AREA 11 -4" ="„V• 1 1AIl k 4. A I +h?•�.r OPEN TO LOBBY 11-4" L /DAT, r� .ar, SEATING 301 LOBBY HALLWAY 8 1 - 8" EXISTING LUNCH 7' -0" 4' -4" EXISTING FILES AREA EXISTING FILES /COPY/WORK EXISTING MAIL /SUPPLIES EXISTING CONFERENCE r "^ ^,ELECTRICAL ROOM 1. ALL WALL INFILLS TO ALIGN WITH ADJACENT SURFACES ON EACH SIDE. r .r.N..■ r OFFICE H 307 I DEMOLITION / CONSTRUCTION NOTES: OFFICE H 306 I OFFICE - 305 I r r.r.M r OFFICE H 304 1 PATCH WITH ACCENT CARPET AT THIS AREA. SHARED OFFICE 303 4 PLACE NEW WALL MINIMUM DIMENSION FROM HVAC DUCT ABOVE. 5 18" MIN. 1=1 OM CONFERENCE 302 DEMOLITION / CONSTRUCTION KEYNOTES: 0 EXISTING CONSTRUCTION TO BE REMOVED. O 2 EXISTING POWER POLE TO BE REMOVED/ RELOCATED, SEE ELECTRICAL/ COMMUNICATIONS PLAN (TI -5) FOR NEW LOCATIONS. O EXISTING HEADER TO BE DEMOLISHED. DEMOLISH EXISTING CEILING SOUTH OF NEW DEMISING WALL. SEE REFLECTED CEILING PLAN (TI-4) FOR PORTION OF EXISTING HEADER TO REMAIN. 12" MIN. AREA OF WORK uY1 SCALE: 1/8"=V-0" STAY FEC EXTERIOR DECK 0 5' 10' [ ±1 DEMOLITION/ CONSTRUCTION PLAN 20' NORTH 30' I INTERGATE WEST BUILDING C 12101 TUKWILA INTERNATIONAL BLVD. TUKWILA, WASHINGTON 98168 Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: NG, SH JOB NO.: 07000.001 CHECKED BY: SN DATE: 12/4/07 PERMIT SET SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A GENERAL REVISION PER CITY COMMENTS REPRODUCTION, ALTERATION OR PUBUCATION OF THIS DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2007. DATE wt( In TENANT: M E D DATA EXPANSION JAN 14 2008 6selr €& I\9 a.3, SHEET TITLE: THIRD FLOOR DEMOLITION/ CONSTRUCTION PLAN TI -3 OF 5 E C- Q 0 Cl, . c 0 Q x w 6 a 0 cn N v 0 C a J C N th Q � E OPEN TO LOBBY LOBBY PPM PIMP NMI CZ w9' w - MME --I OEM I NE AREA OF WthK 4, ELECTRICAL ROO . MillIEN1111=111111 MINNOW MOM rail I ~ I MINIM MIME 11■11_il_ • •ilUi.■E•N B■■� __•.Nr i•N•• 111 II i �oI i4 ■ mammiliiimmi■m• GENERAL CEILING NOTES: 1. EXISTING LIGHT SWITCHES NOT TO BE USED ARE TO BE DEMOLISHED. PULL WIRES AS NECESSARY & PATCH TO MATCH ADJACENT. 2. RE- CIRCUIT SWITCHING OF EXISTING LIGHTING AS NECESSARY TO COMPLY WITH NEW LIGHTING LAYOUT. CEILING KEYNOTES: O NO CEILING IN THIS AREA. O EXISTING HEADER TO REMAIN. O PLACE NEW LIGHT MINIMUM DIMENSION FROM EXISTING HVAC DUCT. O NEW SUITE MASTER SWITCH LOCATION. O CONTRACTOR TO VERIFY SWITCHING. RECIRCUIT AS NECESSARY TO COMPLY WITH NEW LIGHTING LAYOUT. IF NECESSARY, DEMO WALL SWITCHES AND PATCH AND PAINT TO MATCH ADJACENT CONSTRUCTION. T LIGHTING CALCULATIONS: LIGHTING CALCULATION FOR CORRIDOR ONLY: ALLOWED WATTAGE AT ENTIRE CORRIDOR: AREA = APPROXIMATELY 810 USF 811 SF x .8 WATT/ SF = 648.8 WATTS PROPOSED WATTAGE AT NORTH & SOUTH ENDS OF CORRIDOR: (3) NEW B/S 1' X 8' FLUORESCENT PENDANT LIGHT FIXTURES @ 96 WATTS = 288 WATTS SUMMARY: PROPOSED WATTAGE IS LESS THAN ALLOWED WATTAGE. LIGHTING CALCULATION AT NEW OFFICES ONLY: ALLOWED WATTAGE AT NEW OFFICES: AREA OF WORK = APPROXIMATELY 1,036 USF 1,036 SF x 1.0 WATT / SF =1,036 WATTS PROPOSED WATTAGE AT NEW OFFICES: (10) NEW B/S 2X4 LIGHT FIXTURE @ 96 WATTS EACH = 960 WATTS SUMMARY: PROPOSED WATTAGE IS LESS THAN ALLOWED WATTAGE. 0 CEILING PLAN SCALE: 1/8 " =1' -0" 5' 1 10' 20' NORTH 30' p NO. A INTERGATE WEST BUILDING C 12101 TUKWILA INTERNATIONAL BLVD. TUKWILA, WASHINGTON 98168 Marvin Ste DRAWN BY: REVISIONS /ISSUANCE: TENANT: SHEET TITLE: planning sociates, LLc design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 NG, SH JOB NO.: 07000.001 CHECKED BY: SN DATE: 12/4/07 REVISIONS INDICATED THUS n GENERAL REVISION PER CITY COMMENTS THIRD FLOOR CEILING PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2007. PERMIT SET SCALE: AS NOTED DATE M E D DATA EXPANSION 01/11/08 JAN 14 2008 @fi - -c CENTER TI -4 OF 5 0 —•-•"" U") co cr) 0 0' 0 0 - Ft) LJ 0 0 0 0 0 cl) Cr) 11.) 0 s_ a> 0 1 Cr) C r) I OD < 'DO c E 0_ c■.1 C c:;) CP 6 u — LD1=u DECK 0 —{ 307 I 4 ELECTRICAL 308 H 306 I FEC —I 305 I STAIR ••6 •• , `T, CR El OPEN TO LOBBY ,7 T-17'4.t . - - H 304 I I 300 I @+48" LOBBY H 303 I Th- • • :."." •41111143gsit',ViiiiVI.4'1 • ei4l'• 1".. r, ir 301 I 302 LE 0 EXISTING POWER POLES TO BE RELOCATED TO COORDINATE WITH NEW FURNITURE LAYOUT. ELECTRICAL/ COMMUNICATIONS KEYNOTES: AREA OF WORK 0 '',,Alk '''7=.. • ----1 Lop,,,i,„IpALFpg „, - "Ter'1',,,,, g.43 .,. , , ,, ,, , , ::: :,,,... t .4.-.„.„ , „ : „. ! . iliEfaMbr SCALE: 1/8"=1'-0" FEC 0 5' 10' 20' ELECTRICAL/ COMMUNICATIONS PLAN NORTH 30' lemem■mm DO 7- 1 -1 5 Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441-1449 DRAWN BY: NG, SH JOB NO.: 07000.001 CHECKED BY: SN DATE: 12/4/07 PERMIT SET SCALE: AS NOTED REVISIONS/ISSUANCE: NO. INTERGATE WEST BUILDING C 12101 TUKWILA INTERNATIONAL BLVD. TUKWILA, WASHINGTON 98168 REVISIONS INDICATED THUS A TENANT: SHEET TITLE: MED DATA EXPANSION THIRD FLOOR ELECTRICAL/ COMMUNICATIONS PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESS PERMISSION BY MS&A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS&A 2007. DATE JAN 1 4 2008 PERM iT CENTER TI-5 OF 5