Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D07-468 - WESTFIELD SOUTHCENTER MALL - BARE ESCENTUALS - TENANT IMPROVEMENT
BARE ESCENTUALS 827 SOUTHCENTER MALL D07 -468 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D07 -468 Occupant/Tenant: BARE ESCENTUALS Building Address: 827 SOUTHCENTER MALL, SUITE NO. Parcel No.: 6364200010 Property Owner: WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 Use: RETAIL Occupancy Group/Division: M Type of Construction: II -B Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: 32 THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: Contact Person: Name: Address: Phone: DESCRIPTION OF WORK: TENANT IMPROVEMENT Value of Construction: Type of Fire Protection: Type of Construction: City ,f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 827 SOUTHCENTER MALL TUKW BARE ESCENTUALS 827 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 BOB ROBINSON 37936 23 PL S , FEDERAL WAY WA 98003 253 677 -6874 Contractor: Name: TRAINOR COMMERCIAL CONSTR Address: PO BOX 406 , SAN ANSELMO CA 94979 Phone: 415 259 -0200 Contractor License No: TRAINCC950LW $183,000.00 SPRINKLERS /AFA HB DEVELOPMENT PERMIT * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 04/29/2010 Fees Collected: International Building Code Edition: Occupancy per IBC: D07 -468 05/12/2008 11/08/2008 $2,987.70 2006 0019 doc: IBC-10/06 D07 -468 Printed: 05-12 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D07 -468 Issue Date: 05/12/2008 Permit Expires On: 11/08/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signatur Print Name: doc: IBC -10/06 N Date: ocfri-1,71 I hereby certify that I have read and x • ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo c of work. I am authorized to sign and obtain this development permit. Signature `' k�L Date: t 1a d a WA Irt t Sit This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D07 - 468 Printed: 05-12 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 827 SOUTHCENTER MALL TUKW BARE ESCENTUALS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D07 -468 ISSUED 12/19/2007 05/12/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the doc: Cond -10/06 D07 -468 Printed: 05-12 -2008 doc: Cond -10/06 err City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Building Official from requiring the correction of errors in the construction documents and other data. 18: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (1FC 1008.2) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate 007 -468 Printed: 05-12 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 32: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 35: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 36: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** 007 -468 Printed: 05-12 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Signature« t4 Print Name: t D" 11 Kit S Date: Sll�la�' D07 - 468 Printed: 05-12 -2008 SITE LOCATION i � t ,��/�� �p,� King Co Assessor's Tax No.: � �_ 0 0 Site Address: ! e So � •, t Tl Ce- /1 1 YV ► ► 1 Suite Number: rig Floor: Tenant Name: t L'S C- t1T1�1 A-LS New Tenant: ❑ Yes ❑ ..No Property Owners Name: W EST F1 1) CO��O fl O QQ Mailing Address: tl1Pb I WILSVI ' L-VP . 1 14111 R- / LOS 6!n,-, 1,0� ' C - I 002_5 City state Zip CONTACT PERSON - who do we contact when your permit h ready to be issued Name: B . • I ris> en - - Day Telephone: 7_5: 4,7 7- bo?I st Mailing Address: �� Z-3 Yd ri' S �4 lAkel �}- City State E -Mail Address: ptor►�1'/ �! ��� cp �° �rnC • .fi Fax Number: 2 s � —64 1 , 0 9 9 I F ..r 1 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical eechanical (p 4) for Plumbing and Gan Piping (pg 5)) 1 Company Name: "I !V O• N fmb - VI� tc_1 1 O ? INC • Mailing Address: S \ o Contact Person: BO Pd TgAi 1i F� � E -Mail Address: I J l: 11 (Inn Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: T C/Th ....ASSOC-4 (02 - "t itT F , /� (� Mailing Address: 1-1 I I fl / SAN 1 NcZcO '7�' IO Contact Person: hI 1 e ► r ' 1 / I e'T 1 !� ((( Day Telephone: ��' 3tp 2 `5 tp City tate Fax Number: l si 7 7 E Ma11 Address: � � 3 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record WrikS ENG 1 sktizlt.14 Company Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tukwila.wa. us Q:Wpplications\Forms- Applications On Lme\ -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. Va Mechanical Permit No. /V1, D1 - G� Plumbing/Gas Permit No. WO" Public Works Permit No. Project No. Po For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** City sta Zip Day Telephone: 03 3 2S"j — 52-1) O Fax Number: ( i 2S' 7 - C2-?) I Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 0 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 18 3 � o O o. DO Existing Building Valuation: $ Scope of Work (please provide detailed information): I Nii 0- - m - N mac m Pia► n r Will there be new rack storage? ❑ Yes 1" Floor Floor 3 Attached Oarage Deck g N l/- NIA Interior Remodel 13'3 5T. N 1� r Addition to Exiting Structure N Type of Construction per Type of Occupancy per IBC Oft PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) N Il *For an Accessory dwelling, provide the following: N 1/T_ Lot Area (sq ft): Floor area principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: N'14-- Compact: Handicap: Will there be a change in use? ❑ Yes V. No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None Q:\Applications \Forms- Applications On Line\3 -2006 - Permit Application. doe Revised: 9 -2006 bh No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safe Data Sheets. SEPTIC SYSTEM 0 ❑ On -site Septic System -- For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Pagc 2 of 6 PUBLIC WORKS PERMIT INFORMATION - 206 - 433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑... ValVue ❑...Sewer Availability Provided Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public _ ff Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Call before you Dig: 1- 800 -424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Highline ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑ .. Renton ❑ .. Seattle Se tic System: [� On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance WO # WO # WO # ❑ ...Deduct Water Meter Size Private Private ❑ ...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation " Domestic Water " FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser is 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 1 Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM I Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206-431-3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): fO 1(-0, bob Scope of Work (please provide detailed information): T. E - ry o RK . 1\1 6 `1 VA-V - g U ) W !! 1 New alc.�tiJog. 4-1R -viST Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ Fuel Type: Electric ❑ Gas .... Other: V kV- v) Indicate type of mechanical work being installed and the quantity below: Q:tApplications'FmmsApplications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 t Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain ' Sinks I Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERNIIT INFORMATION - 206-431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: State Zip Contact Person: E - Mail Address: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide de filed information): 0 1 N otAATI I N c 1 c UvA -Tee GYv Building Use (per Int'1 Building Code): Re I A- I Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:Wpplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Fax Number: I gooli Page 5 of 6 E PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINGN R UTHORIZgD AGENT: Signature: Date: 1 7 16 7 Print Name: � 1 r) Mailing Address: ,7 23 rd a'. s Date Application Expires: ai / ti 10 Date Application Accepted: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: FIMPOt 1 149, City WA' ' FD D3 State Zip Staff Initials: r , Page 6 of 6 Parcel No.: 6364200010 Permit Number: D07 -468 Address: 827 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/19/2007 Applicant: BARE ESCENTUALS Issue Date: Receipt No.: R08 -01565 Initials: JEM User ID: 1655 Payee: TRAINOR COMMERCIAL CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount don! Rnrs int -flfi Payment Check 19747 2,047.07 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 000/322.100 000/345.830 000/386.904 RECEIPT Account Code Current Pmts Payment Amount: $2,047.07 Payment Date: 05/12/2008 12:06 PM Balance: $0.00 1,808.00 234.57 4.50 Total: $2,047.07 2276 05/12 9711 TOTAL 2047.07 Printal. 05- 17 -900R Receipt No.: R07 -02804 Payee: TECTA ASSOCIATES ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: D07 -468 Address: 827 SOUTHCENTER MALL TUICW Status: PENDING Suite No: Applied Date: 12/19/2007 Applicant: BARE ESCENTUALS Issue Date: Initials: JEM Payment Date: 12/19/2007 10:25 AM User ID: 1165 Balance: $2,047.07 TRANSACTION LIST: Type Method Description Amount Payment Check 2674 940.63 Account Code Current Pmts 000/345.830 940.63 Total: $940.63 Payment Amount: $940.63 6264 12/19 9710 TOTAL 940.63 doc: Receiot -06 Printed: 12 -19 -2007 Project: v / Dad" e .r5e-e-47 Type of Inspection: P./ Addres s 727 70 Date Called: Special Instructions: Date Wanted 7/24/6 1 :11 Requester: Phone No: Iv INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: / /n/Y e/12/2/e/e/ I Inspector: $58.0 paid INSPECTION RECORD. Retain a copy with permit Date: INSPECTION FEE REQUIRED. Prior to inspection, fee must be 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: PERMIT NO. Project & fe . SGe0 / . /s Type of Inspection:_. ' f't'�?lli Address: /)//// Date Called: Special Instructions: Date Wanted:7/?/O 4)7 �.Ry m. Requester: Phone N S g5 / 0330 £07 -c/ ' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. Zfrorrections required prior to approval. COMMENTS: Nit Ce4ly rate?/,r/ P (Inspector: $60.09 %REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid fit 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: .g ame II Cst e 1)tLtJ� Type of Inspection:,— , , ,- t o 2 Address: 8_27 & t/ Date Called: Special Instructions: Date Wanted: 7/ 7 / / Requester: Phone No: /I INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. COMMENTS: I/ OK - rn se_k/5f -FE (Inspector: El $60.0 paid Corrections required prior to approval. (Date: 74-7/08 itN SPECTION FEE REQUIRED. Prior to inspection, fee must be 00 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: �,l`t e-Yl-� `�c Type of Inspection: ! a � o � • l Address: Date Called: Special Instructions: Date Wanted: 7 f t a.m. p.m. Requester: Phone No: )! INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 giv4 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 1 jr (lnspecto . (Date: - / / U $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. !Receipt No.: 'Date: Project ,oil re e c ' AJf2 eetc Type of Inspection: F/2 /77/4/6 Address: Z 7 /)'I f3- // Date Called: - Special Instructions: Date Wanted: --77- Qe a.m p.m. Requester: Phone No: ,12/y -637 -6/7 7 ICJ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 a Approved per applicable codes. COMMENTS: pA \/../A IIS I H 5f, /Z,yJ/oo.— (Inspector: El $60.00 El PECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: El Corrections required prior to approval. I Date: 7r Proje t: /7r� �sc�F.A./ s Type of Inspection: A Ad ess: , '7 fr'� // Date Called: Special Instructions: Date Wanted: 2C� ` U� . . p. . Requester: Phone No: any - 63 - 6//7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 0 Approved per applicable codes. FO Corrections required prior to approval. COMMENTS: 89 filer? I(TC 'Inspector: i El $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r eceipt No.: 'Date: 'Date: COMMENTS: Type of Inspection: F ✓2 / ,i-► /ale / 1, i 7 e J /, I el / �) /) ell /✓I r'/ - 7 ) 0 /-°!I / / //c-7/ / =''[ l Special Instructions: _. Z • P/1-(ii/Z/;'1 /HZ( .5 1 6.- C' /)/6 //e !7 (' / /)d' 1 Y-'/'G v-4 i i1 - /!4l T� 4''7 , i!!/1 Phone No: /y &32- - 6 11"7 / l Project:, f16/�c" oVC Type of Inspection: F ✓2 / ,i-► /ale Address: (5)?. 7 /1141/ Date Called: Special Instructions: _. Date Wanted: 6 - Z,3 -0° p.m. Requester: Phone No: /y &32- - 6 11"7 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. 15Z Corrections required prior to approval. 'Inspector: / INSPECTION RECORD Retain a copy with permit r3 'Date: 1 3/; S� U $60.0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: ;S ara os'F f4 Type of Inspection: w3 Addre Date Called: Special Instructions: Date W anted: / C, (; - / / v e a r p.m. Requester: Phone No: 2J 0)Z -6f/7 7 DO q6° INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: H''e �; 5 V eq € (Inspector:/ (Dace: �/ ❑ $60 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa' t 6300 Southcenter Blvd., Suite 100. Call to scheddte reinspection. (Receipt No.: 'Date: r Project; el,sefArk4k Type of Inspection: Address: ?Z7 1774// Date Called: Special Instructions: Date Wa ted: �_ / rl� p.m. Requester: Phone G : ,� // 63Z -//7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: J7/ /?2 /d/ El $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid a 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Projec , /541 &ci iv -'2(4 / Type of Inspection: ,c Address: eq27 ,en /7// Date Called: Special Instructions: E.2,77/ r 7/� / r',,vc , ./ p / *ASr 32 / /icJG£e1/5 <Y2'.s /f'nyl / Date Wanted: /' f/ 7- e91 a.m. Requester: Phone No /: -763= INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ./4 PS Gl-S/ ect - uln rf/5 (IAA hard t;c y' 4 tom 00) cost r∎ d a r (Inspector: (Date: / %2 El $60 99 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: !Date: D47-qo& PERMIT NO. K_ (206)431 -3670 Proj y Type pnspection: A dd d /7 Date Called: Special Instructions: Date W nted: 6 -& -��_ �,� ..� / •m• • Requester: Phone No: o? /y - 63 2 - (1 /---? a Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r�tG�r. C/ 1 fl ? 1 (Date: r_ El $60.00 RE FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Inspector: 'Receipt No.: 'Date: 1 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 67 PERMIT NO. 1'S (206)431 -3670 Projekt: Type of Inspection i;s: _ Address: 7 Ill A r I , Called: Special Instructions: _ Date Wanted: p.m. Requester: Phone No: 707 ( 1g 1 - S582- _3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 I:I Approved per applicable codes. COMMENTS:V ?et- r oD AllfAde-c/ 'Date: _ er / e9 4 er...., El $58.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid a1 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit D0 PERMIT NO. (206)431-3670 Corrections required prior to approval. COMMENTS: 9 ok- -1 k,„‘,- p, 4-- -,- I' 4 r.rf..0 (..---., I/ S. Address: 6 / 2.7 /9 '9 si CiPli e^.. .'l ei. 1 F :f 4 ,e( reA ,- ,-. s €-- Pe .., € 44 itd., S Special Instructions: Date Wanted: / 5 Requester: Phone No: 7D7 -- 5? ...._._ Project: 6 , Type of Inspection: Fibeivin /A.) Address: 6 / 2.7 /9 '9 ( Date Called: Special Instructions: Date Wanted: / 5 Requester: Phone No: 7D7 -- 5? INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes: Inspector: PERMIT NO. 11* (206)431-3670 EJ Corrections required prior to approval. Date: 4Er O $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Proje 4 �" 1'9 j e of l EC to in G) Ad 6027 P7.47/( d: Date Called: Special Instructions: Date Wanted: ,y_ �� Vi. � Requester: Ph . neeoN i, ./ CJ � i PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Vt 6300 Southcenter Blvd.;. #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. J Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Ptecc»i s4 iie %q 0 $58.00 SPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit Project: We_ C Sc e N - v'v S Type of Ins qn: Ci r - -e-- , P0 - 1. — Address: -� ,s C Suite #: g� y „�,� L Contact Person: Special Instructions: N Phone No.: Needs Shift Inspection: - Sprinklers: Fire Alarm: V Hood & Duct: N Monitor: �,aU,r,O, k ,J Pre -Fire: 0 0 Permits: t) Occupancy Type: A"-- INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 P pproved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: Inspector: I Date: 7 wa h g Fthe O $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: &ILL " F S CL Nr`r t'. MS Sprinklers: Type of nspection: csA S i° Address: Suite #: 460 .. '5. C . tv\r - (..- Contact erson: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Ia, Wa. 98188 206- 575 -4407 INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT [ ipproved per applicable codes. INSPECTION RECORD Retain a copy with permit o�- s- - X3 pa-") - clo op - s Is i PERMIT NUMBERS r7 Corrections required prior to approval. COMMENTS: r„ S (Z se j;: - ©rc f 25 1 (4 f :iv Inspector: Date: 7 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project:c C s5 - n 5 Type of Inspection: SP2I6AtkLC k Hood & Duct: Address: $z- S , e . Suite #: Mme.. ` Contact Person: Co-A-0 - W. S.-s Occupancy Type: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 2 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: Dem bK / Co Jed-- OIL l 5-O,rz -r 2-2-27 (v l ono ..H414) 4312- I Date: 5 /L f . U g Hrs.: 2. Inspector: glitJ jj n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 aTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing Report Number: 87953 Description: Epoxy Grouting (Reber) CONSTRUCTION INSPECTION REPORT Project: Bare Essentials Permit Number. B07 -468 Address: 1139 South Center Mall, Tukwila Job Number. 08 -0418 Client: Adek Construction Client Address: 23423 14 Avenue S, Des Monies Inspector and Date Remarks Randy Carpenter Inspected epoxy - grouted rebar at slab trench holes and found the following: 6/13/2008 RECEIVED DEEV o Simpson ET epoxy with an expiration date of 11/30/2009 was used. o #4 rebar, grade 60 from Cascade was epoxy - grouted to an embedment depth of 5 ". o All holes were blown clear of debris, brushed dean, and drilled to a proper diameter. Epoxy grouting at the above locations conform to the Engineer of Record's specifications. Copies to: X Client Contractor Architect X Building Dept. Technical Responsibility: X Engineer to F` C-xt4/ j' -' David Lyal, Technical Director This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except In full, without written permission from our firm Is strictly prohbited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1- 888 - OTTO -4 -US - Fax (206) 723 -2221 Form No.: ADMIN -63 -01 (Rev 05/03) ImelP OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing Job Number: 08 -0418 CONCRETE REPORT Report Number: RC75251 Permit Number: B07 -468 Specimen Test Field Age Size Area Weight Max Load Strength Fracture Type Number Date Cure (Days) (in.) (Sq.ln.) (Lbs.) (Lbs.) (psi) (other than cone) 1 6/26/08 7 4 x 8 12.58 8.71 41,970 3340 Discarded Tested in general accordance to: ASTMC39 0 ASTMC617 ❑ ASTMC1231 ❑ Copies to: J Client ❑ Contractor ❑ Architect © Building Dept Engineer [] Batch Plant Technical Responsibility: _ David Lyal, Technical Director This report applies only to the items tested or reported and Is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report except in full, without written permission from our firm is strictly prohibited. 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725 -4600 or 1- 888- OTTO -4-US - Fax (206) 723 -2221 Form No.: ADMIN -62 -04 (Rev 09/06) RECEIVED JUL 2 3 SW Project: Bare Essentials Client: Adek Construction Address: 1139 South Center Mall, Tukwila Address: 23423 14th Avenue S, Des Moines Inspector: Dwayne Helgeson Date: 6/19/2008 DEVELOPMENT Description /Location: Inspected reinforcing steel and placement of concrete for slab -on -grade infill at storage /bathroom with #4 bars at 18" on center each way with vapor barrier. Resteel Verified: Yes 6/19/2008 by Dwayne Helgeson Grade: 60 Mfg: Cascade Placement Data Design © Actual = Batch Weights /Cubic Yard Supplier: Corliss Cement (lbs/type): 705# Mix Number: S15000 Fine Agg. (lbs): 2396# Slump Spec: 4" t 1" Coarse Agg. (lbs/size): 738# 1/2" Slag (lbs): W/C Ratio Spec: Coarse Agg. (lbs/size): 2078# 3/4" Air Spec: N/A Coarse Agg. (lbs/size): Total Yards: 1.50 Fly Ash (Ibs): Placed Via: Wheelbarrow Water (lbs or gal): 130# Consolidated: Yes Admixtures (specify): Required Strength (psi): 3000 Sampling and Testing Data Time Cubic Water Slump Air % Conc.Temp Ambient Truck Ticket ASTM C 172, C 31 Made Yards Added C 143 C 231 C 1064 Temp No. No. Cast Samples: 1 -4 2:20 pm 1.50 5 gal. 4 1/2" N/A 73 °F 71 °F 115 39976 Weather. Inside Slump Range: -- Air % Range: -- Date Samples Picked Up: 6/20/2008 Initial Curing Method: Excluding ASTM c31 -121.5 Initial Curing Temp: Excluding ASTM C31- 1D.1.2 Comments REINFORCING / PLACEMENT: Conforms © Does Not Conform ❑ COMPRESSIVE TEST RESULTS Page 1 of 1 SS. .. . IS .. - - .a - .-. - .- . ..' 11111 .. . .. Lighting, Motor, and Transformer Permit Plans Checklist Project Address The following information is necessary to check a permit application for compliance with the lighting, motor, and transforme requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) yes yes z.a. yes yes z.a. yes yes Code Section LIGHTING CONTROLS (Section 1513) 1513.1 Local control/access Schedule with type, indicate locations 1513.3 Daylight zone control Schedule with type and features, indicate locations 1513.2 Area controls Maximum limit per switch 1513.4 1513.5 1513.6 1531 1532 MOTORS (Section 1511) BARE ESCENTUALS Component vertical glazing overhead glazing Display /exhib /special Exterior shut -off Inter. auto shut -off Interior Lighting Summary Form Exterior Lighting Summary Form Information Required Indicate vertical glazing on plans Indicate overhead glazing on plans Indicate separate controls Schedule with type and features, indicate location (a) timer w/backup Indicate location (b) photocell. Indicate location Indicate location 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 1E2 EXIT SIGNS (Section 1514) I 1514 Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 - 1532) Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture z. a. 1511 lElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) �. a. I 1540 (Transformers 'Indicate size and efficiency 'Date il oP la ti �EVIEWED FOR C 5DE COMPLIANCE . APPROVED FEB -1 2008 E3 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.7 Commissioning Indicate requirements for lighting controls commissioning E2 Of ila City ILD NC DIVISION 2006 Washington State Nonresidential Energy Code Compliance Forms If "no" is circled for any question, provide explanation: FILE COPY Pr rrit Men NONINIMOMp r RECEIVED CITY OF TUKWIIA DEC 19 2001 pkI tMIT CENTER 4(eg •. .• k•• .-• _ . . •.- • u• _• .en LTG -CHK Lighting, Motor, and Transformer Permit Plans Chef ter 12/14/2007 Revised Juy 2007 2006 Washington State Nonresidential Energy Code Compianoe Forms Building Department Notes Lighting - General Requirements 1613 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1613.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant-sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.6 Automatic Shut -off Controls, Exterior. Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either. a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1613.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied (lours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring mans, the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufa facilities as may be required for produc 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental performed are exempt from the occupy requirement. 1513.6.1 Occupancy Sensors: Occupant be capable of automatically turning off all tl area, no more than 30 minutes after the are vacated. Light fixtures controlled by occupancy sens wall- mounted, manual switch capable of tut when the space is occupied. EXCEPTION: Occupancy sensors II allowed to have two step lighting (high- light) provided the control fails in the hi 1513.6.2 Automatic Time Switches: Autc switches shall have a minimum 7 day clock of being set for 7 different day types per we incorporate an automatic holiday "shut -oft" turns off all loads for at least 24 hours and 1 normally scheduled operations. Automatic t shall also have program back -up capabilitie the loss of program and time settings for at power is interrupted. Automatic time switches shall incorporate switching device which: a. is readily accessible; b. is located so that a person using the de' lights or the areas controlled by the switch, area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no m when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft building footprint for footprints over 100,00( greater. 1513.7 Commissioning Requirements: F controls which include daylight or occupant automatic controls, automatic shut -off contt sensors, or automatic time switches, the lig shall be tested to ensure that control device equipment and systems are calibrated, adjt. in accordance with approved plans and ape Sequences of operation shall be functionall ensure they operate in accordance with apI specifications. A complete report of test pr results shall be prepared and filed with the notes shall require commissioning in accon paragraph. 1514 Exit Signs: Exit signs shall have an i demand of 5 Watts or less per sign. Motors - General Requirement 1511 Electric Motors: All permanently wir motors of 1 hp or more, which are not part r system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are a specialized process equipment. 2. Where the motor is integral to a Ii equipment for which no complying mot approved. Transformers - General Requit SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltag distribution transformer shall be the Class I for distribution transformers specified in Tal "Guide for Determining Energy Efficiency fc Transformers" published by the National El Manufacturers Association (NEMA TP -1 -20 requiring manual operation of systems. trial or manufacturing process ired for production. ratory spaces. dical or dental tasks are Dm the occupancy sensor rs: Occupancy sensors shall :uming off all the lights in an as after the area has been cupancy sensors shall have a c capable of turning off lights 3ncy sensors in stairwells are lighting (high-light and Iow- a! fails in the high -light position. witches: Automatic time .m 7 day dock and be capable iy types per week and iday "shut-off' feature, which 24 hours and then resumes ns. Automatic time switches < -up capabilities, which prevent settings for at least 10 hours, if call incorporate an over -ride n using the device can see the by the switch, or so that the unciated; in on for no more than 2 hours ; and eding 5,000 ft or 5% of the s over 100,000 ft 2 , whichever is luirements: For lighting ht or occupant sensing c shut-off controls, occupancy Nitches, the lighting controls t control devices, components, :alibrated, adjusted and operate plans and specifications. I be functionally tested to dance with approved plans and sport of test procedures and I filed with the owner. Drawing oning in accordance with this shall have an input power er sign. Revised July 2007 quirements srmanently wired polyphase h are not part of an HVAC action 1437. Dtors that are an integral part of ipment. c integral to a listed piece of complying motor has been Aral Requirements ORMERS of a low voltage dry-type be the Class I Efficiency Levels specified in Table 4 -2 of the 3y Efficiency for Distribution :he National Electrical 'IEMA TP- 1- 2002). 6 Washington State Nonresidential Energy Code Compliance Form Fan Equipment Schedule Equip. ID Brand Name' Model No.1 CFM SP HP/BHP Flow Control Location of Service Location TUKWILA, NA • 1EVIEWED FOR COMPLIANT APPROVED APPROVED Applicant Name: Ammo MJ1/AZAt3 RECEIVEC CITY OF TUM CODE Applicant Address: 2747 19TH STREET, SAN FRANCISCO, CA 94110 Applicant Phone: 415- 362 -5857 DEC 1920 pEtiMI I (;LN I Cooling Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 m Total CFM OSA CFM or Econo? SEER or EER IPLV Location TUKWILA, NA • 1EVIEWED FOR COMPLIANT APPROVED APPROVED Applicant Name: Ammo MJ1/AZAt3 CODE Applicant Address: 2747 19TH STREET, SAN FRANCISCO, CA 94110 Applicant Phone: 415- 362 -5857 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity2 Ruth Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiencv TUKWILA, NA • 1EVIEWED FOR COMPLIANT APPROVED APPROVED Applicant Name: Ammo MJ1/AZAt3 CODE Applicant Address: 2747 19TH STREET, SAN FRANCISCO, CA 94110 Applicant Phone: 415- 362 -5857 Project Info Project Address BARE ESCENTU LS Date 12/14/2007 633 s00THCENTER PARKWAY For Building Dept. Use TUKWILA, NA • 1EVIEWED FOR COMPLIANT APPROVED APPROVED Applicant Name: Ammo MJ1/AZAt3 CODE Applicant Address: 2747 19TH STREET, SAN FRANCISCO, CA 94110 Applicant Phone: 415- 362 -5857 Mechanical Summary ■• • - •-• - ► ' • NO' • n • . • •. • ••• MECH -SUM 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description Briefly describe mechanical system type and features. Q Indudes Plans pew ' Fie%_ FILE COPY Include documentation requiring compliance with commissioning requirements, Section 1416. Ci 7 Of Tukwila BUILDING DIVISIC �r On.S . FEB -1 2008 Compliance Option • Simple System 0 Complex System Q Systems Analysis • (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the I plans. For projects without plans, fill in the required information below. applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). ILA ER ' If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as 41 1 (01 System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: 0 Constant vol? D Air cooled? 0 Packaged sys? 0 <20,000 Btuh? 0 Split system? 0 Economizer included? If Heating Only: 0 <5000 cfm? 0 <70% outside air? Mechanical Summary (back) 11• 1. • •• •• - ••• - •-• . •- • •.• •u• .• • MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Complex Systems I Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Project Info Project Address SAKE EscJ�Trmrs Date 12/14/2007 6 Watts/ Fixture 26.0 75.0 For Building Department Use FILE COPY No 633 sakrraCtecrr$R PARKWAY TOIDTILA, NA Applicant Name: Applicant Address: 2747 19TH STREET, SAN FRANCISCO, CA 94110 Applicant Phone: 415 - 362 -5857 Pen d)!# ai New Building Q Addition 0 Alteration Refer to WSEC Section 1513 for controls i afid'cdmmissioning Project Description 0 Plans Included regni�01tVtc*4 a r^70,vM Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) Q No changes are being made to the lighting Q Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) SPACE SPACE nA Da Number of Fixture Description Fixtures 6 Watts/ Fixture 26.0 75.0 Watts Proposed 104.0 450.0 •i14 �� �� CODE COMPLIANCE SPACE DC _ 1 540.0 540.0 SPACE rs 24 44.0 1056.0 SPACE rai 1 2008 13 44.0 572.0 SPACE rc [LB 1 26.0 26.0 SPACE IT 40/14 32 37.0 1184.0 8> 1 ?!f O f Tu iIa 16 25.0 400.0 SPACE rrz D ■ . ! - . _ ION _ .: 4 28.0 112.0 SPACE a - _ ... _ . 17.0 17.0 SPACE rs 4 62.0 248.0 Location (floor /room no.) Occupancy Description Allowed Watts per ft ** Area in ft Allowed x Area SPACE RETAIL 1.50 1260.0 1890.0 SALES MERCHANDISE DISPLAY 1.50 1785.0 2677.5 SPACE 2% INCREASE FOR SLIGHT PER FOOT Or 4042.5 mars 0.04 4042.1 161.7 Interior Lighting Summary 1 . A. . .. .. - .. . - . - . - • se .... .1 - • Al LTG -INT 2006 Washington State Nonresidential Energy Code CcmpOance forms Maximum Allowed Lighting Wattage From Table 15-1 (over) - document all exceptions on form LTG-LPA Provosed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Allowed Watts otal Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the facture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all factures. For exempt liahtina. note section and exceotion number. and leave Watts/Fixture blank. RECEIVED CITY OF TUKWU A DEC 19 2001 PEKN1iT E NTE Revised July 2007 4729.2 4709.0 and om Use' LPA` (W /sf) Use' LPA`(W /sfl Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to school% hospitals, institutions, museums, banks, churches) .7 1.0 Convention center 1.2 Penitentiary and other rouo 1 -3 Occuoancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments', restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms. day care centers 1.2 ii Gymnasia assembly spaces 1.0 Theater motion picture 1.2 Health care clinic 1.0 Theater oerformina arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses " . storaae areas 0.5 Hotel banquet/conference/exhibition hall''` 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundrie? 1.2 Libraries 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (exceot mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms. elevator lobbies 0.8 Prescriptive Spaces Occupancy: a Warehouses, storage areas or aircraft storage hangers a Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elee- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. 11• _ a le as - - ►.l - • Interior Lighting Summary (back) I' • as ono - • s ii LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised ,Ny 2007 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter-height partitions (transparent or opaque). and lighting for free-standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address BARE EScEIITOALS 'Date 12/14/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component 'Information I Required FILE COPY Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance Peer It N n.a. 1411.4 Pkg. elec. htg.& dg. e List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment ul w tl pe, capacity, efficiency 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss • 1 1412 HVAC controls t `�Y ' r 1< yes 1412.1 Temperature zones Indicate locations on plan `O � v �C LIAA1 yes 1412.2 Deadband control Indicate 5 degree deadband minimum COD ■ (OM 1412.3 Humidity control Indicate humidistat . PR V tEll 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day pes 1412.4.1 Dampers Indicate damper location and auto. controls & max. le kage FB _ tuuB 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule ��a 1412.6 Combustion htg. Indicate modulating or staged control t O� WW . yes 1412.7 Balancing Indicate balancing features on plans Wall OW 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy - - -s 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate dg load & water econoe & dg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M yes 1414.2 Duct insulation Indicate R -value of insulation on duct M2 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1434 Separate air sys. Indicate separate systems on plans ' Mechanical Completed and attached. Equipment schedule with types, Summary Form linput/output, efficiency, cfm, hp, economizer I SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. RECFIVFI OF TUKW1L . 1441 Elec. water heater Indicate R -10 insulation under tank CI1Y yes 1442 Shut -off controls Indicate automatic shut -off E2 EEC 1 9 zoos n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 PEHMIT GEN [ER 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover DOI 6 1454 Pools 90+ degrees Indicate R -12 pool cover I Enerav Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: • 2006 Washin ton State Nonresidential Ener• Code Corn • liance Form • Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packages ele ctric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced toe minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. it must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: if an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 dm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 • 2006 Washin ton State Nonresidential Ener• Code Corn • liance Form • Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14-1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packages ele ctric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced toe minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. it must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: if an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 dm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 dm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14-5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1416 Piping Systems 1416.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) 05 -08 -2008 BOB ROBINSON 37936 23 PL S FEDERAL WAY WA 98003 RE: Permit Application No. D07 -468 827 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 12/19/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 06/16/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 06/16/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall t Technician Permit File No. D07 -468 city of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 December 20, 2007 Bob Robinson 37936 23` P1 S Federal Way WA 98003 RE: Letter of Incomplete Application # 1 Development Permit Application D07 -468 827 Southcenter Mall — Bare Escentuals Dear Mr. Robinson, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on December 19, 2007 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 431 -2440 if you have any questions concerning the following comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messen,4er service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Enclosures File: D07 -464 e""&ip Bill Rambo Permit Technician City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director P:\Permit Center\Incomplete Letters \2007\D07 -468 Incomplete Ltr #I.DOC wer 1. Please make provisions for one drinking fountain per IBC 2903.4.1 Washington State Amendments 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tenant Acknowledgment Letter [Date] o, r c t.44 JAN 22 2008 Tukwila i Building Division/Permit i Suite 100 Center �'FRM /r czNrEfs Tukwila, WA 98188 Tenant improvement permit for [tenant name], Tukwila Permit No. issued subject to the following condition: This condition is hereby acknowledged by: Title': Tenant Name: Final inspection approval of this permit and approval of occupancy (i.e. Open for Business) for the herein named tenant space will not be issued until the "shell" Building Permit No. D06 -147 has received fmal inspection approval from the Building Division. 1 Note that the letter is to be signed by the responsible officer of the tenant (ie business manager, business president, vice president, CEO etc). The contractor, contact person for the project nor the architect will not be acceptable. ACTIVITY NUMBER: D07 -468 PROJECT NAME: BARE ESCENTUALS SITE ADDRESS: 827 SOUTHCENTER MALL DATE: 01 -22 -08 Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: BuSltii Ig vision Public Works Complete Comments: Please Route Documents/routing slip.doc 2 -28-02 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES/THURS ROUTING: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP C REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Fire Prevention Structural Incomplete ❑ Structural Review Required C No further Review Required DATE: DATE: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 01-24-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: C DUE DATE: 02 -21-08 Approved ❑ Approved with Conditions El Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: 17-"/ \.29( Buil•� g !vision Public Worics Complete ❑ Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D07 -468 DATE: 12 -19 -07 PROJECT NAME: BARE ESCENTUALS SITE ADDRESS: 827 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued - 511 /rub Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only i 1 INCOMPLETE LETTER MAILED: I�4e — 0 7 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: 1YJ DUE DATE: 12-20-07 DATE: DATE: Planning Division 1 Permit Coordinator n Not Applicable n No further Review Required C DUE DATE: 01-17-08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: /ettp: //www.ci.tukwila.wa.us Steven M Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc Date: J-- 2-2-- 201* Plan Check/Permit Number: Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued 17v L-1111 P'. CEIVED " JAN 22 2008 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: f � S ✓'T /�'' I Project Address: ( &e J- 24 Contact Person: Phone Number: / 3 1 4477 7� Summary of Revision: /}5 7.'et0 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 1/6 Entered in Permits Plus on lcpplicationslfonns- applications on lindrevision submittal Created: 8-13-2004 aviQ,ti• Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 1 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 It Water closet, tank or valve, >1.6 GPF 8 4 — King County Department of Natural Resources and Parks Wastewater Treatment Division Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type g 2%7 So e-0114 Pot( Property Street Address Vw ALA WA City &ere. CE TC3 LS Owner's Phone Number (with Area Code) 20 State Owner's Name Subdivision Name Lot # Subdiv. # Block # Building Name (if applicable) Property Contact Phone Number (with Area Code) Owner's Mailing Address ( $ TeY 0 D S T. 22ND FL12 SA-n9 re"n cv zf l _ 4 1 K1 S i'c. A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units RCE TA)/4 Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner /Representative c '/' . r 1 M, Date 1 i 0 /e'7 RCE Ig ZIP 1 For King County Use Only Account # No. of RCEs Monthly Rate Property Tax ID # '3 tP 'TZC " C OI Party to be Billed (if different from owner) ov A City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre - existing building? ❑ Yes n No Was building on Sanitary Sewer? K ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No B. Other Wastewater Flow 4— (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) RECEIVED CITY OF TUKWILA DEC 1 v2 0 FEHNit CI M ER A B RCE Business declaration Part I Fill out this form, fold it so the business-reply Po, i shag and return it to Metro's industrial Waste section. If you need to use additional sheets cf `a p eai,Hi+6` paeTKage of infoiutation in a separate envelope. Mail to: Metro, Water Pollution Control Department, Industrial Waste Section, 130 Nickerson Street, Suite 200, Seattle, WA 98109 -1658. •� ari ;np rouctron areas { or any IR � i�l� yi iY 1fiFr 51+c'If yoiihave 111131 thaix=one pv .. • Qfi It Q Yes O No If yes, are they for resale? Yes No 4. Does your company use solvents pi substances? Yes NO If yes, do you recycle them? . ..Yes •❑ No' • 5. Does ybui teitpany:proa3sfood.Or inintal matter ? .' 11JNTY Pi 821 2ND AVE. SEATTLE WA 98104 -9986 9 Q Yes 6. Does your company uSe. or metal solutions is manufacturing, processing, .tr!eath% waste, etc.? III Iit IS! IL UPI IIIII VIII.,I1I /IIII,III,II111II111 • Titattj O QE_:... I Titj s. L 1MT_o STATES . License Information License TRAINCC950LW Licensee Name TRAINOR COMMERCIAL CONSTR Licensee Type CONSTRUCTION CONTRACTOR UBI 602512116 Ind. Ins. Account Id #1 Business Type CORPORATION Address 1 PO BOX 406 Address 2 City SAN ANSELMO County OUT OF STATE State CA Zip 94979 Phone 4152590200 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/29/2005 Expiration Date 4/29/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 DEVELOPERS SURETY & INDEM CO 547292C 06/22/2005 Until Cancelled $12,000.00 06/29/2005 Business Owner Information Name Role Effective Date Expiration Date TRAINOR, BRIAN PRESIDENT 06/29/2005 TRAINOR, SUZANNE VICE PRESIDENT 06 /29/2005 Look Up a Contractor, Electric; an or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TRAINCC950LW 05/12/2008 VICINITY MAP KEY PLAN CODE INFORMATION DES: 2006 GOVERNING INTERNATIONAL CO BUILDING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL PLUMBING CODE 2006 INTERNATIONAL GAS CODE 2006 INTERNATIONAL FIRE CODE 2003 INTERNATIONAL ACCESSIBILITY CODE BLOCK: ZONING: CONSTRUCTION CLASSIFICATION: IIB OCCUPANCY: M, MERCANTILE OC CUPANT LOAD: SALES AREA 915 5Q. FT. / 30 SQ. FT. = 30.5 OFFICE AREA 200 SQ. FT. / 100 5Q. FT. = 2 H.C. RESTROOM 45 SQ. FT. = ACCESSORY USE TOAL AREA 1,160 Q. T. RESTROOMS: PROPOSED HDCP UNISEX RESTROOM REQUIRED EXITS: 1 REQUIRED, 1 PROVIDED SPRINKLER SYSTEM: FULLY SPRINKLERED AND MONITORED SYSTEM 4 NORDSTROM ��� ~Or O r ^ ' macy� __-_ � ® I -5 1 \ _ ° ° ° ° o o � ° o o ©o w • r5 0 �� h ° a �� r4-7 4 NNW* . CO CO Q SOUTHCENTER PARKWA` D ❑ _ ° — Bid . °. • ° b.. a 633 S Tukwila e I d S o u th ce o u t h ce n to r WA 9S n to r P a rkwa SS -2SS8 \ Q 'CV ` v ` 1 O � , ° ° c ' associates • ARCHITECTURE • INTERIORS • PLANNING I /---,. \ >i, �� -A. �� A' �: IJ SITE F • d w r ui 1 ANDOVER o PARK WEST m m iX w Q 'e = � _ _ �. - .� ' ' ! BARE ESCENTUALS 2747 19th STREET SAN FRANCISCO, PH: 415- 362 -5857 15 36225044 4 BARE S C E N T U A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 N m PARK EAST N ABBREVIATIONS GRAPHIC SYMBOLS / LEGEND INDEX OF SHEETS REVISIONS PROJECT INFORMATION ABV ABOVE LH LEFT HAND A/C AIR CONDITIONING ACP ACOUSTICAL LAY -IN H METER PANELS - REGULAR HAS. MASONRY GRID - (SCRUBABLE) MAX. MAXIMUM AC. PL. ACOUSTIC PLASTER M.C. MILLWORK CONTRACTOR ACT ACOUSTICAL TILE - MECH MECHANICAL MOUNTED ON MEZZ MEZZANINE SUSPENSION MFG. MANUFACTURING OR SYSTEM MANUFACTURER MIS[ MISCELLANEOUS AFF ABOVE FINISHED FLOOR MM MILLIMETER AHU AIR HANDLING UNIT MIN MINIMUM AL ALUMINUM NIC NOT IN CONTRACT AT NTS NOT TO SCALE ALT ALTERNATE ANOD ANODIZED DC ON CENTER AT ASPHALT TILE DTO OUT TO OUT BF BARRIER -FREE P. POINT BL. BLOCK PART. PARTITION BR. BRICK PLASTER -PLATE PL PROPERTY LINE CC CENTER TO PLAM PLASTIC LAMINATE CENTER PLUM PLUMBING C.D. CEILING DIFFUSER PNL PANEL C.J. CONTROL JOINT PNT PSF PAINT C.L. CENTER LINE POUNDS PER SQUARE FOOT C CEMENT PSI POUNDS PER SQUARE INCH CL CLOSET CG CORNER GUARD PWD PLYWOOD CIRC CIRCUMFERENCE QT QUARRY TILE CONST. CONSTRUCTION CONT. CONTINUOUS CLG CEILING RB RUBBER BASE CM CENTIMETER R.A. RETURN AIR CMU CONCRETE MASONRY R.A.R. RETURN AIR REGISTER UNIT REFR REFRIGERATOR COL COLUMN REG. REGISTER CONC CONCRETE REQ REQUIRED COORD COORDINATE REST. RESILIENT TILE CPT CARPET RH RIGHT HAND CT CERAMIC TILE RM. ROOM CTB CERAMIC TILE BASE RO ROUGH OPENING DF DRINKING FOUNTAIN S.A. SUPPLY AIR S.C. SELF CLOSING DIA DIAMETER S.C.W.D. SOLID CORE WOOD DOOR D.O. DOOR OPENING 5-6 SEMI -GLOSS DIM. DIMENSION SIM SIMILAR ON DOWN S.P. STANDPIPE DTL. DETAIL SPK SPEAKER EA EACH 5Q SQUARE E.A.S. ELECTRONIC ARTICLE SURVEILLANCE SS STAINLESS STEEL E.C. ELECTRICAL CONTRACTOR ST. STEEL OR STREET E.G. EXHAUST GRILLE OR STAIR ELEV ELEVATION STD. STANDARD ELEC ELECTRIC ELECTRICAL STOR STORAGE EMER EMERGENCY STRUCT STRUCTURAL ENCL. ENCLOSURE SYS SYSTEM E -S EGG SHELL EWC ELECTRIC WATER COOLER TEL TELEPHONE TOILET EXIST. EXISTING TERR. TERRAllO FA FIRE ALARM T.O. TRIMMED OPENING F.A.I. FRESH AIR INTAKE TOM TOP OF MASONRY F.O. FLOOR DRAIN TOP TOP OF PIER FE FIRE EXTINGUISHER T.O.S. TOP OF SLAB FEC FIRE EXTINGUISHER CABINET T.O.W. TOP OF WALL F.F. FINISHED FLOOR T .O. TYPICAL FIN. FINISH T &G TONGUE FLR FLOOR, FLOORING AND GRDOVED F.O. FINISHED OPENING TV TELEVISION F.P.S.C. FIREPROOF SELF CL051NG F.R. FIRE RATED UNFIN. UNFINISHED F.R.P. FIBERGLASS REINFORCED PANELS UNO UNLESS NOTED F.S. FULL SIZE FT FOOT, FEET OTHERWISE VB VINYL BASE GC GENERAL CONTRACTOR VCT VINYL COMPOSITION TILE GL. GLA55 VEST. VESTIBULE GYP. BD. GYPSUM BOARD VIF VERIFY IN FIELD GWe GYPSUM DRYWALL V.T. VINYL TILE VWC VINYL WALL COVERING H.CLG. HUNG CEILING HGT. HEIGHT W/ WITH HM HOLLOW METAL WB WALL BASE HVAC HEATING /VENTILATING/ WC WATER CLOSET WD WOOD INCL INCLUDE, INCLUDING, WO WITHOUT INCLUDED (E) EXISTING INS. INSULATION (N) NEW J.B. JUNCTION BOX (R) RELOCATED J.C. JANITOR'S CLOSET LANDLORD REQUIRED NOTES: 1. Tenant's general contractor shall submit a construction de with Landlord's on -site representative per Center requirements. 2. Tenant's general contractor must schedule a pre- construction meeting with Landlord's on -site representative prior to work start. P p 3. Tenant's contractor will repaint and /or repair Landlord's property, (neutral piers, bulkheads, rear corridor, etc.) damaged during Tenant improvement. 4. ALL ceiling material must have a minimum of a class "A" fire rating. 5. Support wires for lay -in ceiling grid, lights, HVAC equipment, etc. must not be connected to any of Landlord's electrical, plumbing, fire protection piping and mechanical equipment or deck above. 6. All support wires may only be connected to top cord of joist and /or structural members. 7. All materials used in the construction of this space must be asbestos free. 8. Food related Tenants and Tenants with bathrooms shall provide a waterproof membrane in wet areas. Verify water test procedure with Landlord's on -site representative. 9. Do not channel cut slab. Core drill only and install supplemental support framing. 10. Any penetration or modifications to structural steel or concrete must be coordinated and approved by Landlord's on -site representative. 11. It is the responsibility of the Tenant's architect to field verify dimensions, utility locations s prior and conditions and during construction. 12. Tenant shall not penetrate Landlord's metal roof deck with any type fasteners. 13. It is Tenant's responsibility to maintain the integrity of Landlord's demising walls, floor slab, roof and building structure. T -1 COVER SHEET / PROJECT I N F O R M A T I O N PROJECT ADDRESS: BARE ESCENTUALS WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 LANDLORD: WESTFIELD CORPORATION 11601 WILSHIRE BOULEVARD, 14TH FLOOR LOS ANGELES, CA 90025 ATTN: JOSH KIMMEL TEL: 310 -478 -4456 FAX: 310 - 575 -5991 OWNER: BARE ESCENTUALS 71 STEVENSON STREET, 22ND FLOOR SAN FRANCISCO, CA 94105 ATTN: SAMANTHA SHEILDS TEL. 415 -489 -5180 FAX: 415- 520 -9653 ARCHITECT: TECTA ASSOCIATES 2747 - 19TH STREET SAN FRANCISCO, CA 94110 ATTN: AHMAD MOHAZAB TEL: 415 -362 -5857 FAX: 415-362-5044 GENERAL CONTRACTOR: TRAINOR CONSTRUCTION, INC. 769 CENTER BLVD., #170 FAIRFAX, CA 94930 ATTN: BRIAN TRAINOR TEL: 415 - 259 -0200 FAX: 415 - 259 -0231 LIGHTING VENDOR: REXEL CAPITOL LIGHT 1000 SANSOME STREET, STE. 380 SAN FRANCISCO, CA 94111 TEL: (877) 247 -0187 FAX: (415) 956 -3907 FIXTURE MANUFACTURER: B & N INDUSTRIES, INC. 1409 CHAPIN AVENUE, 2ND FLOOR BURLINGAME, CA 94010 ATTN: GWEN GONZALES EMA 1 : GGONZALE5[G16NIND.COM SIGNAGE VENDOR: COLITE INTERNATIONAL, LTD. 229 NORTH PARSON STREET WEST COLUMBIA, SOUTH CAROLINA 29169 ATTN: SHANNON M. SOMERVILL TEL: 800.760. x130 MUZAK MUZAK 15083 WICKS BOULEVARD SAN LEANDRO, CA 94578 ATTN BILL EG GLESTON TEL:510- 618 -1540 1 fizz RECEIVED RECEIVED OF TUKWILA DEC 1 D 2007 PEHMIT CENTER pc) v ARCHITECTURAL EXISTING TO REMAIN G -1 GENERAL INFORMATION �n NEW PARTITION G -2 ACCESSABILITY NOTES G -3 MATRIX OF RESPONSIBILITY NEW ITEM - - - - -- ITEM TO BE DEMOLISHED — — — SOFFIT ABOVE THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEMI WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. A -1 CONSTRUCTION PLAN & A -2 FIXTURE PLAN, NOTES & SCHEDULE A -4 REFLECTED CEILING PLAN, NOTES & SCHEDULE A -5 FINISH FLOOR PLAN, NOTES & SCHEDULE �N# PA RTITION TYPE A -6 ENLARGED H.C. UNISEX RESTROOM PLAN AND ELEVATIONS OFFICE ROOM IDENTIFICATION REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET ig A -7 INTERIOR ELEVATIONS & NOTES A -8 STOREFRONT ELEVATIONS, DETAILS & NOTES 1 100 I A -9 STOREFRONT SECTIONS DO2 DOOR NUMBER 19 A -10 DETAILS A -12 DETAILS A -13 DETAILS v,..... Ra •TEREC) ,, ° \v' i 1 AO MO ZAB L TE OF W GTON - � t ENGINEERING A3.1 ELEVATION TAG WORK POINT O KEY NOTE FINISH TAG 19 14. Tenant to remove any existing or newly abandoned materials, equipment, piping, ducts and wiring from the premises. Cap service at point of origin and coordinate this work with Landlord's on -site re resentative. P 15. Tenant must comply with Title III of the American's with Disabilities ACT (ADA) and all Local and State codes. M_1 MFrHANIrAI [FILING PLAN M-. MErHANIrAI NOTES DETAILS, R. SrHEDI II FS P_1 PI 11MRING Fl QDR PI AN P -2 PLUMBING NOTES. DETAILS. & 16. Free standing security devices are not allowed in the control zone. Security devices shall be concealed from public view. 17. Tenant is to maintain any expansion joints within their leasable area. Install cover plates per Center requirements. 18. Television antennas and satellite dishes are not permitted on the roof or attached to HVAC units. 19. Tenants requiring cable television should refer to their lease and contact the Landlord's on -site representative for additional information. 00°- h�, SF �� :. E -1 SYMBOLS AND NOTES rr //�� Vl 11 sa) 4 C a) CO CO CO E -2 SINGLE LINE DIAGRAM E -3 LIGHTING PLAN E -4 POWER PLAN E -5 SIGNAL PLAN SECTION CUT A3 -1 -c,eA IA L �' L F� F`' v-53 R- SEPARATE P ERMIT REQUIRED F �M�tianical leCtriCal plumbing Gas Piping City of Tukw BUILDING DIVISION �, N z C O W U CO �✓ ♦ Q) °° A...0 CD r —) BLOWUP DETAIL _ MEWED FOR CODE COMPLIANCE APPROVED F EB 1 I �a� 1C A3.1 I �) I / ` REVISION DELTA / CLOUD C Q) v 0 ll~= -1--+ _ 06 Q CO N /� ® NORTH ARROW , ELECTRICAL PANEL I Of Tukwila ; �1. , � N FILE COP �: . Permit No. Pte' Gnus and orris& Approval of not ogle violation 00de or 01�. of + condition � Imo` -E--• rr ^^ W • -1—, 41 g CO <F- F- O Z a O E.P. PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: W1 WALL TYPE DESIGNATION - SEE A2.1 ll iI Cate: 5 l (1-'1'4 ( D01 EQ UIPMENT OR FURNITURE DESIGNATION X Tukwila rr 1 DIVISION �I)i���� V�Si�iY -. _.....__...- ._..._. - -._ ---_. ._......_-- ...--- ..... _ . _ . ... __ N®cha s shall made to O t work,, , � approval of Tukwila Building DOT i NOTE: Revisions will requite a a nd may include ad ditional r . SCALE: (DO NOT SCALE DRAWINGS) + 12' -6" A.F.F. INDICATES ELEVATION OF SHEET TITLE: TITLE SHEET & PROJECT INFORMATION PROJECT NOTES r FIRE DEPARTMENT NOTES GENERAL NOTES ® A. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT L ING THAN 2A:10BC WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. B. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. C. PROVIDE EMERGENCY LIGHTING OF ONE FOOT CANDLE AT FLOOR LEVEL COMPLY WITH BUILDING CODES. D. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS. E. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. F DOORS OPENING INTO REQUIRED 1 -HOUR, FIRE- RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP BY ASSEMBLY HAVING A 20- MINUTE RATING AND SHALL BE SELF CLOSING. G. 20- MINUTE DOOR JAMBS TO BE TIGHT - FITTING, SMOKE AND DRAFT CONTROLLED. H. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA. I. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING: 1. CLASS I, FLAME SPREAD 0 -25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. 2. CLASS II, FLAME SPREAD 26 -75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS, 3. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALSINSTALLED IN ANY OTHER LOCATION. J. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE NON- COMBUSTIBLE OR BE FLAME PROOFED IN AN APPROVED MANNER. K. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE -RATED WALLS OR CEILINGS. L. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM FIRE CODE REGULATIONS. M. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDNANCE WITH APLLICABLE CODE REQUIREMENTS. N. EXTEND OR MODIFY EXISTING FIRE /LIFE SAFETY SYSTEM AS REQUIRED TO PROVIDE AN APPROVED FIRE /LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT WITH COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION, AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 0. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. P. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE. Q. EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHERS SYSTEM AS REQUIRED TO PROVIDE AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT AND OBTAIN APPROVAL PRIOR TO INSTALLATION. R. AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL, PROPRIETARY OR REMOTE STATION SERVICE OR A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION. . 34. CEASE OPERATIONS AND NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. TAKE PRECAUTIONS TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUME OPERATIONS UNTIL SAFETY IS RESTORED. 35. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION 36. ALL WORK SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES AS ADOPTED BY THE AUTHORITIES HAVING JURISDICTION. 37. GENERAL CONTRACTOR SHALL KEEP THE APPROVED, PERMIT DOCUMENTS STAMPED SET ON THE JOBSITE AT ALL TIMES. 38. ALL ROOFING WORK TO BE PERFORMED BY LANDLORD'S ROOFING CONTRACTOR AT TENANT'S EXPENSE. 39. ALL SPRINKLER WORK TO BE PERFORMED BY LANDLORD'S SPRINKLER CONTRACTOR AT TENANT'S EXPENSE. 40. WATER SUBMETER TO BE PROVIDED BY LANDLORD AT TENANT'S EXPENSE. 1. FOR PURPOSES OF THESE DRAWINGS, THE TERMS "TENANT ", "OWNER" AND "BARE ESCENTUALS" SHALL BE USED AND INTERCHANGABLE. 2. FOR PURPOSES OF THESE DRAWINGS, THE TERMS "GENERAL CONTRACTOR ", "G.C." AND "CONTRACTOR" SHALL BE USED AND INTERCHANGABLE. 3. ALL WORK SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES AS ADOPTED BY THE AUTHORITIES HAVING JURISDICTION. 4. ALL WORK SHALL BE IN ACCORDANCE WITH THE MOST STRINGENT BARRIER-FREE 1BILI ACCE55TY REQUIREMENTS OF "ANSI A117.1 ", "THE AMERICANS WITH DISABILITIES ACT" ACCESSIBILITY STATE AND LOCAL REGULATIONS, CODES AND ORDINANCES. 5. GENERAL CONTRACTOR SHALL KEEP THE APPROVED, PERMIT DOCUMENTS STAMPED SET ON THE JOBSITE AT ALL TIMES. 6. GENERAL CONTRACTOR SHALL OBTAIN ALL PERMITS (INCLUDING LOW VOLTAGE INSTALLATIONS AS REQUIRED BY JURISDICTION HAVING AUTHORITY), APPROVALS, INSPECTIONS, CERTIFICATE OF COMPLIANCE, CERTIFICATE OF OCCUPANCY AND /OR INTERMEDIATE (TEMPORARY) CERTIFICATE OF OCCUPANCY. 7. GENERAL CONTRACTOR SHALL CONFIRM THAT ALL LOW VOLTAGE VENDORS HAVE ALL REQUIRED PERMITS PRIOR TO VENDORS COMMENCING WORK. B. GENERAL CONTRACTOR SHALL OBTAIN ALL REQUIRED SPECIFICATIONS AND SHALL INSTALL ALL MATERIALS PER MANUFACTURER'S RECOMMENDATIONS /REQUIREMENTS AND ARCHITECTS' REQUIREMENTS, WHICHEVER IS MORE RESRICTIVE. 9. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DISTRIBUTION OF COMPLETE SETS OF CONTRACT DOCUMENTS (DRAWINGS & SPECIFICATIONS) TO ALL TRADES. EACH TRADE SHALL REVIEW ALL CONTRACT DOCUMENTS TO BE AWARE OF ALL ITEMS OF WORK AFFECTING THEIR RESPECTIVE TRADE. NO CLAIMS FOR "EXTRAS" WILL BE HONORED DUE TO FAILURE TO REVIEW COMPLETE SET OF THE DOCUMENTS. 10. ADJACENT TENANT(S) WILL OCCUPY ADJOINING AREAS /ROOMS DURING THE ENTIRE PERIOD OF CONSTRUCTION. THE CONTRACTOR SHALL ARRANGE WITH AFFECTED TENANT(S) TO MAKE ALTERATIONS, PERFORM NEW WORK AND MAKE CONNECTIONS TO MECHANICAL AND ELECTRICAL SYSTEMS AT SUCH TIMES AS NOT INTERUPT SERVICES OR OPERATION OF THE BUILDING AND WHICH ARE OTHERWISE CONVENIENT AND SATISFACTORY TO ADJACENT TENANT(S). 11. GENERAL CONTRACTOR SHALL COORDINATE ALL ITEMS FURNISHED AND /OR FURNISHED AND INSTALLED BY VENDORS. 12. FIELD VERIFY EXISTING SITE CONSTRUCTION, CONFIGURATION AND DIMENSIONS. GENERAL CONTRACTOR TO CONFIRM ALL DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS OR ELEVATIONS SHALL BE RESOLVED WITH THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. 13. ALL TRADES SHALL COORDINATE THEIR WORK WITH FIXTURE INSTALLERS AND CONTRACTORS. 14. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY. ® ...,.....046111 __ 4--AN � • �A � associates • ARCHITECTURE • INTERIORS • PLANNING y� 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 FX:415 - 362 - 5044 BARE E S C E N T U A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF HARE ESCENTUALS. ANY REPRODUCTION ,MODIFICATIDN,DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEMI WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 15. INTERIOR DIMENSIONS ARE GIVEN TO THE FINISHED FACE OF WALL CONSTRUCTION, UNLESS NOTED OTHERWISE. 16. LANDLORD IS RESPONSIBLE TO PROVIDE TEMPORARY PROTECTION AND BARRICADES AS REQUIRED THROUGHOUT RENOVATION. 17. ALL NEW ACOUSTICAL CEILING TILES SF 18. ALL WOOD FRAMING, SHEATHING, BLOCKING PROVIDE WOOD BLOCKING AT WALL AND FASTENED OVER FINISHED SURFACES. 19. PRIOR TO INSTALLATION OF NEW FIRE Ewe'. EXTINGUISHER CABINETS, GENERAL CO LOCATIONS OF NEW AND EXISTING FIRE EXTINGUISHERS WITH THE AUTHORITY HAVING JURISDICTION. GENERAL CONTRACTOR SHALL LOCATE THE FIRE EXTINGUISHERS AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION OF ANY LOCATIONS THAT DIFFER FROM THOSE SHOWN IN THE CONTRACT DOCUMENTS. 20. THE G.C. TO BE RESPONSIBLE FOR PROTECTING (FLOORS, CEILINGS AND WALLS) FROM DUST, DIRT AND DEBRIS IN ORDER TO BE SUITABLE FOR INSPECTIONS AND STOCKING 21. DO NOT INSTALL DAMAGED ITEMS. 22. ALL NEW WORK SHOWN, IS BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. THERE IS NO DELINEATION OF RESPONSIBILITY ON THE DRAWINGS, UNLESS OTHERWISE NOTED. 23. THE CONTRACTOR MUST COORDINATE ALL DELIVERIES WITH STORE MANAGEMENT AND RECEIVING DOCK PERSONNEL. VERIFY DOCK HOURS AND SCHEDULES PRIOR TO BIDDING. 24. UPON AWARD OF CONTRACT, THE GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE LIST OF EMERGENCY PHONE NUMBERS, LISTING PERSONNEL, INCLUDING AFTER HOURS PHONE AVAILABLE TO THE PROJECT MANAGER AND THE STORE MANAGER, AT THE FIRST PROJECT MEETING. LANDLORD WILL ALSO PROVIDE AN EMERGENCY CONTACT LIST. 25. ALL CONTRACTORS SHALL OBTAIN PRIOR THE FREIGHT ELEVATOR, AND NO CONSTRUCTION MATERIALS SHALL AT ANY TIME, BE TRANSPORTED IN THE PASSENGER ELEVATORS. GENERAL CONTRACTOR, TO PROVIDE DEBRIS BOXES FOR CONSTRUCTION MATERIALS. STORE FACILITIES MUST NOT BE USED. 26. NO SALVAGING OF CONSTRUCTION MATERIALS AND DEBRIS WILL BE ALLOWED, UNLESS OTHERWISE NOTED, OR DIRECTED BY THE LANDLORD CONSTRUCTION MANAGER. 27. THE CONTRACTOR WILL TAKE MEASURES TO PROTECT THE OWNER'S PROPERTY, AT ALL TIMES, INCLUDING BUT NOT LIMITED TO: FLOORS, WALLS, FIXTURES, DISPLAYS AND MERCHANDISE. THIS PROTECTION SHOULD INCLUDE PATH -OF- TRAVEL TO AND FROM MATERIAL STORAGE AND DEBRIS DISPOSAL AREAS. 28. DUST CONTROL BARRICADES AND WALK -OFF MATTS SHALL BE PROVIDED AS DIRECTED BY THE LANDLORD PROJECT MANAGER, OR AS NOTED ON DRAWINGS. 29. ALL INTENSIVE NOISE AND DUST RELATED WORK, INCLUDING DEMOLITION, CONCRETE SAW CUTTING, HARDWOOD FLOOR SANDING, OR BB BLASTING, WILL BE DONE ON AN "OVER- NIGHT" LOCK -IN BASIS, AT NO ADDITIONAL CHARGE TO LANDLORD. IF THE CONTRACTOR REQUIRES IN- AND -OUT ACCESSIBILITY, THEN THE CONTRACTOR WILL PROVIDE A LANDLORD APPROVED GUARD SERVICE, AT THE CONTRACTOR'S OWN COST. THE HVAC AND FIRE PROTECTION SHALL BE DESIGN- BUILD, AND COMPLY WITH ALL APPLICABLE CODES. 30. NO INTERRUPTION OF WATER SERVICE SHALL BE ALLOWED DURING CUSTOMER HOURS. STORE SECURITY IS REQUIRED TO HAVE 24 -HOUR NOTICE OF ANY SPRINKLER TESTING OR SYSTEM DRAINING. r'-�y TIVED OF 31, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE VISIBILITY ACCESS TONE W UMV(LP► CONSTRUCTION, FOR CITY INSPECTORS, AS REQUIRED. ANY CUTTING AND PAT G 1 9 200 RELATING TO ACHIEVING ACCESSIBILITY, WILL BE DONE AT THE CONTRACTOR'S EXPENSE. PERMIT CENTER 32. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, TO IDENTIFY ANY DISCREPANCIES BETWEEN THESE PLANS, AND ACTUAL FIELD CONDITIONS. DISCREPANCIES ARE TO BE RESOLVED BEFORE CONSTRUCTION BEGINS, AND /OR BEFORE MILLWORK IS FABRICATED. 33. PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE(S). DESIGN FOR, PROVIDE AND PLACE BRACING OR SHORING AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURE. ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT, DAMAGE, OR INJURY. 7716 \ R. GISTERED ' CHIT r ', ,j �,. s A Pip , NAZAR E OF i, A'� \NG i__. --� CEN' Souti ter Park 98188-2 lg Count II I EVIE1f ED FOR CODE COMPLIANCE APPROVED FEB -- 1 2008 City Of Tukwila BUILDING DIVISION D I F � PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: E N E RAL INFORMATION G.1 DISABLED ACCESS NOTES 1. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS LIFTS. 2. FLOOR SURFACES SHALL BE SLIP - RESISTANT. 3. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL NOT BE LESS THAN 44" IN WIDTH. 4. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2"IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NO GREATER THAN 1:2. 5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH -PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE FLOOR FINISH. 6. CENTER HAND ACTIVATED DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE THE FLOOR. 7. MAXMIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS. CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE REQUIRED FIRE DOORS MAY BE INCREASED NOT TO EXCEED 15 POUNDS. 8. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEEL CHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A 10 HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS. 9. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL NOT BE LESS THAN 3' IN WIDTH AND NOT LESS THAN 6' -8" IN HEIGHT . DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32 ". 10. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITTIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 12. THE FLOOR OF LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 44" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. 13. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4"AND 1/2" SHALL BE BEVELLED WITH A SLOPE NO GREATER THAN 1:2. 14. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR WITH A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2" WIDE, PLACE PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSE OF THE STEP OR LANDING. THE STEP SHALL BE OF A MATERIAL THAT IS ATLEAST AS SLIPRESISTANT AS THE OTHER TREADS OF THE STAIR. 15. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESSTHAND 15" ABOVE THE FLOOR OR WORKING PLATFORM. 16. SANITARY FACILITIES LOCATED ON AN ACCESSIBLE FLOOR OF A BUILDING SHALL BE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED. 17. ENTRY TO SANITARY FACILITIES; A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE. B. DOORWAYS TO HAVE A 32" CLEAR OPENING. C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44" SPACE WHEN DOOR SWINGS AWAY FROM APPROACH. 18. TOILET ROOM ACCESSORIES: A. MOUNT BOTTOM EDGE OF MIRRORS NO HIGHER THAN 40" FROM THE FLOOR . B. MOUNT TOILET TISSUE DISPENSES WITHIN 1/2" FROM THE FRONT EDGE OF THE TOILET SEAT. C. MOUNT DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY, NAPKINS, WASTE COIN SLOTS, ETC.) WITH OPERATING PARTS NO HIGHER THAN 40" FROM THE FLOOR. 19. SINGLE ACCOMODATION TOILET FACILITY: A. WATER CLOSET TO HAVE A 28" CLEARANCE FROM A FIXTURE AND 32" FROM A WALL. B. MINIMUM CLEAR SPACE IN FRONT OF WATER CLOSET TO BE 48 ". C. A SPACE 36 "X48" IS PERMITTED IN FRONT OF EXISTING WATER CLOSET ACCESSIBLE TO THE HANDICAPPED. 20. THE HEIGHT OF THE WATER CLOSET(TOP OF SEAT) SHALL BE BETWEEN 17" AND 19 ". 21. MOUNT FLUSH VALVE CONTROL NO MORE THAN 44" ABOVE THE FLOOR, ON THE SIDE OF THE TOILET WITH THE GREATEST SEPERATION FROM ADJACENT WALL OR OTHER SURFACE. 22. PROVIDE GRAB BARS ON EACH SIDE, OR ONE SIDE AND BACK OF WATER CLOSET. A. GRAB BARS TO BE 33" ABOVE AND PARALLEL TO THE FLOOR. B. SIDE BARS TO BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL. GRAB BAR AT BACK TO BE 36" LONG. C. DIAMETER OF GRAB BARS TO BE 1-1/4" TO 1-1/2". D. PROVIDE 1-1/2" CLEARANCE BETWEEN GRAB BARS AND WALL. E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, ETC.) SHALL SUPPORT A 250 POUND LOAD. F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. G. GRAB BARS AND ANY ADJACENT SURFACE SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. H. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". 23. PROVIDE A CLEAR FLOOR SPACE 30 "X48" IN FRONT OF LAVATORY TO PERMIT A FORWARD APPROACH. 24. MOUNT LAVATORIES WITH A MINIMUM CLEARANCE OF 29" FROM THE FLOOR TO THE BOTTOM OF THE APRON. PROVIDE KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30" IN WIDTH WITH 8" MINIMUM WIDTH AND SHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR A MINIMUM OF 17" DEEP FROM THE FRONT OF THE LAVATORY. 25. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL NOT BE GREATER THAN 5 POUNDS. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPETABLE DESIGNS. SELF CLOSING ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 26. INSULATE OR OTHERWISE COVER HOT WATER AND DRAIN PIPES UNDER LAVATORIES. 27. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVARATORIES. 28. THERMOSTATS SHALL BE MOUNTED AT REACH RANGE HEIGHT (48 AFF) PER IBC 11178.6(3). ACCESSIBILITY CLEARANCES PULL SIDE PULL SIDE NOTE: x =12 in. (305 mm) if the door has both a closer and a latch Front Approaches - Swinging Doors NOTE: x =36 in. (915 mm) minimum if y = 60 in. (1525 mm) : x =42 in. (1065 mm) minimum if y = 54 in. (1370 mm) Hinge -side Approaches - Swinging Doors PULL SIDE NOTE: M doors in alcoves shall comply with clearances for front approaches. NOTE: y = 54 in. (1370 mm) minimum if door has a closer E co r E o CV PUSH SIDE PUSH SIDE 54 min. 1370 I NOTE: y =48 in. (1220 mm) minimum if door has both a latch and a closer 24 min. X it 610 PUSH SIDE NOTE: y = 48 in. (1220 mm) minimum if door has a closer Latch -side Approaches - Swinging Doors Two Hinged Doors in Series ACCESSIBILITY CLEARANCES E CV n Knee Clearance 8 min 205 SIDE WALL E • E N CO [0 Q] 4 E 30 min. 760 54 min. Counter 30 min. 760 1370 12 . 42 min. 3051 1065 Side Wall 12 MAX. 305 i 42 min. 42 1065 min. LATCH APPROACH ONLY, OTHER APPROACHES 48 min. (1220). OD 00 Cabinet Heights Base Height 6 max. Toe Clearance ��. 17 min. Lay. Depth 430 Lavatory Clearances 36 max. 915 E ALTERNATE 40 42 min. 36 max. E co CC Lo C7 N N Toilets TOILET PAPER M CO n 305 TOILET PAPER C) 0 CO CO 12 max. 1370 1220 Suggested Supply Lines 17 min 430 ---1r Clear Floor Space 4- 48 min' 19 48 12 min. 36.min. 12 min. Back Wall 12 min. 305 69 min. 42 min. 12 max. 305 54 min. FLOOR -- MOUNTED W.C. WALL - MOUNTED W.0 CO Y is C7 N e 3 REAR WALL 305 U, 0) cc max. D tb RECEIVED CITY OF TUKWILA [FLU 1 9 2007 PEHMIT CENTER • ® • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415 - 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEMI WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/.7 CD SET 7318 AI1MAD ?ATE OF SHI EU ' HfTECT , 4t z U w 4t 0 U 0) PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: ACCESSABILITY NOTES & DETAILS G -2 DESCRIPTION FURNISHED BY INSTALL BY: COMMENTS DESCRIPTION FURNISHED BY: INSTALL BY: COMMENTS T CL T CL T CL T CL GENERAL SALES AREA PLANCHECK FEE • • GWB CEILING • • BUILDING PERMIT • • SEISMIC CEILING / SOFFIT SUPPORT • • TRADE PERMIT • • INSPECTION • • WOOD FL❑ ❑RING • • TEMPORARY HEAT • • SUB-FLOORING • • TEMPORARY ELECTRICAL • • WOOD BASE • • JOB PHONE / FAX • • REDUCER STRIPS • • CLEAN UP • • INTERIOR WOOD TRIM • • INSURANCE • • CAN LIGHTS • • FIELD VERIFICATION • • PENDANTS • • WARRANTIES & BONDS • • PAINT • • CERTIFICATE OF OCCUPANCY •• • •• • WALL COVERING ••• 41;•• CONCRETE SLAB PREPARATION l a FiVTHERfNG IQLJ'fiET SOUND SYSTEM PRE -WIRE SUPPLIED BY MUZAK VENDOR G.C. TO COORDINATE INSTALLATION W/ VENDOR DEMISING WALL STUDS SEE FLOOR PLAN FOR L❑CATI ❑N SOUND SYSTEM / SPEAKERS DEMISING WALL SHEETROCK • • TELEVISION • • DEMISING WALL INSULATI ❑N _ • • CHANDELIER • • FRAMING • • WALL SCONCES • • SH RD; K . • • MILLWORK & CASEWORK • • SUPPLIED BY MILLWORK VENDOR FURRING AND METAL STRAPPING • • MIRROR / IMAGE FRAMES • • CEILING • • CASH REGISTER & WIRING • • CEILING ACCESS PANELS • • FLOORING • • PAINTING / FINISHING • • DOORS & FRAMES y • • DOOR HARDWARE • • FIRE EXTINGUISHERS / CABINET • • LIFE & SAFETY ALARMS o • STOCKROOM LIGHTING • • VCT FL❑ ❑RING • • ELECTRICAL • • VINYL BASE • • MECHANICAL • • WALL SHELVING & STANDARDS • • SUPPLIED BY MILLWORK VENDOR PLUMBING • • REAR SERVICE DOOR • • DESK • • SUPPLIED BY MILLWORK VENDOR PAINT • • ACOUSTIC CEILING TILE • • FLUORESCENT LIGHTING • • DEMO / BARRICADE BARRICADE PANEL & FRAME • • C ❑ORDINATE W/ MALL OPERATIONS MGR. BARRICADE DOOR • • TOILET ROOM BARRICADE GRAPHICS • • SHEET VINYL FLOORING W/ COVE BASE • • DEM❑LITI ❑N • o GWB CEILING • • PAINT • • FRP WAINSCOT • • WALL INSULATI ❑N • • WATERPROOF MEMBRANE • • STOREFRONT GRAB BARS • • STOREFRONT FRAMING (S,F,) • • ACCESSIBILITY SIGNAGE • • S.F. GLAZING SYSTEM • • TOILET FIXTURES & ACCESSORIES • • S.F. GLAZING • • LIGHTING • • S,F, DOORS AND HARDWARE • • IN -WALL BATT INSULATI ❑N o • EXTERIOR APPLICATION ONLY THINSET GROUT AND SEALANT • • MALL FLOORING • • TILE FLOORING • • EXTERIOR APPLICATI ❑N ONLY MARBLE BASE • • PATCH AND REPAIR NEUTRAL PIERS • • PATCH & REPAIR LANDLORD BULKHEAD • ! ,,�, —,-. 1 S.F. VINYL WINDOW GRAPHICS • • .C. TO CO❑RDIANTE W/ SIGN VENDOR Pa �OE ' F l 1 �' "r,re� r �`=- 'g� -7 ` �'� ILLUMINATED SIGNAGE • • I��1- ��- — -,;.- q�� .m. as n I rrn i 1lfQ I q T LL) s 4uu4 I 1 I CitV Of TUKWU I riI IT! nTNG DIJI5L 1 - GENERAL NOTES: 1- REGARDLESS OF THE SPECIFIC SCOPE ITEMS IN EACH ROOM ON THIS SCHEDULE, G.C. IS RESPONSIBLE FOR ALL WORK REQUIRED TO COMPLETE PROJECT, IF THERE ARE ANY DISCREPANCIES OR QUESTI ❑NS REGARDING SCOPE ON ANY ITEM, CONTACT CLIENT PROJECT MANAGER PRIOR TO AWARD OF JOB. 2 -G,C, IS TO CONTACT LANDLORD PRIOR TO PROJECT START, SCHEDULE PROJECT KICKOFF MEETING TO COORDINATE WORK BY LANDLORD. 3 -G,C, IS TO REVIEW LANDLORD TENANT CRITERIA PRIOR TO AWARD OF PROJECT, WHERE SPECIFIC SUBCONTRACTORS ARE REQUIRED BY L.L. THESE SHALL BE COORDINATED BY G.C. IF THERE ARE ANY DISCREPANCIES BETWEEN THE LANDLORD CRITERIA AND C❑NSTRUCTI ❑N DRAWINGS, CONTACT CLIENT PROJECT MANAGER PRIOR TO AWARD OF JOB. L ka RECEIVED CITY OF TUKWILA DEC 19 2007 PEFfMIT CENTER • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 -362 -5857 FX: 415 - 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET CT) L. -Im 0 0 U, U co cu Cu • co > Co L N Co co 0_ co co 0-) Co p F- O CD U C Co a) C!) z 0 U PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: RESPONSIBILITY MATRIX G -3 GENERAL NOTES A. REFER TO GENERAL NOTES ON SHEET G -1. B. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND NOTIFY ARCHITECT OF ALL DISCREPANCIES BEFORE PROCEEDING WITH WORK. C. AFTER REMOVAL OF (El PARTITIONS, CONTRACTOR SHALL V.I.F. LOCATIONS OF ALL VOIDS AND HOLES AND PATCH AND REPAIR AS REQUIRED. D. COORDINATE WITH NEW CONSTRUCTION PLANS THE RELOCATION OF THE (El ELECTRICAL AND DATA LINES TO REMAIN AT SAME RELATIVE LOCATION. E. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE, UNLESS OTHERWISE NOTED. ALL DIMESIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING FLOOR FINISHES. F. REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES. G. ALL EXPOSED GYP. BOARD TO BE LEVEL 5 FINISH,TYP. H. TRANSITION 0 FLOOR MATERIALS TO BE LOCATED AT CENTER OF DOORS IN CLOSED UNLESS OTHERWISE NOTED. I. CONTRACTOR TO ENSURE DELIVERY AND INSTALLATION OF CASEWORK AND FINISH CARPENTRY WILL NOT BE DAMAGED BY OTHER CONSTRUCTION WORK. NOTES: PERMIT IS REQUIRED FOR ALL STORAGE RACK MORE THAN 5' -0" IN HEIGHT. NO RACK IS ALLOWED 12' -0" OR HIGHER. VERIFY WITH FIRE MARSHALL WHETHER SIDE SLIDING STOCK ROOM SHELVING WILL BE ALLOWED SINCE FIRE PROTECTION LANDLORD'S SPRINKLER SYSTEM IS DESIGNED FOR ORDINARY HAZARD GROUP 2. PROVIDE CERAMIC TILE FLOORING IN RESTROOM OVER WATERPROOFING MEMBRANE TO A MIN. 12" UP THE WALL. INSTALL LANDLORD APPROVED LATEX RUBBER WATERPROOFING MATERIAL UNDER THE FLOOR FINISH. THE MEMBRANE SHALL BE MANUFACTURER'S 2 PART FORMULA CONSISTING OF LIQUID LATEX RUBBER AND POWDER FOR TROWEL APPLICATION WITH GLASS FIBER FABRIC REINFORCEMENT (LATICRETE 9235 OR SUMMITVILLE S- 9000). INSTALL A WATER TIGHT DOOR THRESHOLD. G.C. TO VERIFY LOCATION AND GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESTFIELD'S ON SITE TENANT COORDINATOR BEFORE PROCEEDING WITH WORK. NO PEDESTAL SECURITY SYSTEMS WILL BE ALLOWED. UNDER FLOOR TYPE WILL BE ACCEPTABLE. REAR EXIT DOOR AND DOOR ALCOVE TO BE RATED TO MATCH ADJACENT RATING IN CORRIDOR. ALCOVE TO HAVE 9' -O" HIGH GYP. BD. CLG. WITH RECESSED LIGHTING. FINISH DOOR AND ALCOVE TO MATCH FINISH OF CORRIDOR. REFER TO KEYNOTES 14, 15 & 16 AND DOOR SCHEDULE FOR MORE INFORMATION. ■ ® �0041111F-44N ` _ —� ® • • • r 4 4-m \ �� 1 r� �� y� ■ rr�� Q associates ARCHITECTURE INTERIORS PLANNING f KEY NOTES 274719th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415-362-5044 BARE E S C E N T U A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 - 5478 01 LEASE LINE, V.I.F. 0 EXISTING 6" DEMISING DEMISING STUD WALL BY LL TO REMAIN, U.O.N. ® 3 EXISTING NEUTRAL PIER. 04 EXISTING STRUCTURAL COLUMN TO REMAIN. 0 LINE OF SOFFIT ABOVE. ® WALL MOUNTED LCD TV. 0 NEW CASEWORK, SHOWN DASHED, TYP. REFER TO FIXTURE PLAN FOR LOCATION AND CLEARANCE. O8 NEW DOOR AND FRAME. 10 NEW ELECTRICAL PANELIST 11 NEW TELEPHONE BOARD. 12 PROVIDE 5/8" TYPE "X" GYP. BD. @ TENANT SIDE OF DEMISING WALL. 13 PROVIDE 3 -5/8' STUD WALL TO HANG SUPPORT SHELVES, FIXTURES, CABINETRY, ETC... DEMISING WA LL I S NOT DESIGNED TO SUPPORT MERCHANDISE OR FIXTURING. 14 PROVIDE DOOR BELL, CHIME AND LOW VOLTAGE TRANSFORMER, 15 NEW RATED SERVICE DOOR. PROVIDE REAR DOOR SIGNAGE WITH TENANT NAME AND SPACE NUMBER. INSTALL 2" HIGH, DIE CUT, VANDAL PROOF, WHITE HELVETICA BLOCK STYLE LETTERS _ - STEEL; 10 GAUGE STAINLESS STEEL CORNER GUARDS ON 1 L 1 O OUTSIDE CORNER OF THE ALCOVE. THE 1 7 FOCAL WALL DETAIL, SEE 4/A 13. 5' -0" 9' -10" ± 4' -7 1/4" I L-� (E) SERVICE CORRIDOR 0 0 1'-•6" MIN. _ 3' - 0" 0 • 0 C® THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENUSE TOF UAL5 THESE ANY REPRMATERIODUCTION ANY MODIFICPORTATION OF DISTHECLOSURE WHOUT AND /OR ALS (OR ION M) IT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. IN , � - 1 � � - ���/ — = b / f' i :' ' ' . / G - 004 ' 1 .:.. x:::::::::::::: :x:.::.:..::.::.:...:'../ ca z- z I N :.:.:.:..::.:.:k:..::.:.:.•i ::.::.•L 7 � 6 p/1 wi 002 wt m «� W1 m �© co TYP. 6' -8 1/8" 1 6' -O" • / , REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 PCC SET _ m 1 TI® ®I I� ® I W1 wi C 3' -D" 9' -10" 1 J � J/ 9' -10" X 12" X 12" , 1 1 �. W1 0 5' -0 1/4" : _ - SALES € :) f I f 1 1 � �1� ; 0 - \ 0 - �� N 1 ; : I ; I ' I ` ` f I , r ; '• : f STOCKROOM W1 r 1 ; ; ., ; . g ....i /�� • ; , I ` _ 0 " :, I' f f I i ;, 4 ` ,_0 A, 1 1 Ii 1 - ■ \NN''‘, 7 I8 STE: rr y � r y1�p AHMAQ LMP A `. -"ATE O F AS GTON ;..�— °" is 1 j1 1 kJ 001 ass _11" ' _ i t L— I I ogi 7 ' I 0 � ... i o :n \ s• , 0 ! E I �T i; W2 I , ; I i 1 ? - 1 4 1, (€ I 1 m QTY 0° _ - y _ Et t I jI i1 I W2 /' H.C. UNISEX RESTROOM 1 ��� r 0 " / 11 1 :> �. ©, i ; ..... m �© Q° TYP. -' � - i s , I , I I © 0 � EQ. '; `; :;., Z - W1 zL1 I I Q T Y P. DOOR NOTES I 4 003 ® g _p ;, 1- m O ... EQ. I wi 8 '-/11/244 z� -1o" 1. HAVE SIGN ON TOP RAIL STATING "THIS EXIT DOORS AT STORE F TO UNLOCKED DURING BUSINESS HOURS", AS REQUIRED BY CODE. A 2. DOORS WITHIN THE PATH OF TRAVEL FOR HANDICAPPED TO BE OPERA) EFFORT BY LEVER, PANIC BAR OR PUSH /PULL HARDWARE, AS PER Al LE WITH A SINGLE 3. EXIT DOORS TO BE OPERABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 5. DOOR CLOSERS TO BE ADJUSTED TO PROVIDE FOR A MAXIMUM EFFORT TO OPERATE AT LBS. AT FIRE DOOR USE LESS THAN 15 LBS MINIMUM FORCE ACCEPTABLE MARSHAL. THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SC AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 THAT FROM MOVE TO A POINT 3" FROM THE LATCH MEASURED TO THE LEADING EDGE OF THE DOOR. 6. THRESHOLDS SHALL NOT EXCEED 1/2" IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. 7. ALL WOOD AND H.M. DOORS TO HAVE 1 -1/2 PAIR BUTT HINGES PER LEAF. LOCKS ALIKE). 8. BOTH SIDES OF DOORS SHALL BE FINISHED THE SAME, UNLESS OTHER'A ISE NOTED. SEE FINISH SCHEDULE FOR PAINT CALL OUTS. 9. ALL WOOD DOOR FRAMES AND TRIM SHALL BE A.W.I. OR W.I.C. CUSTOM GRADE U.O.N. 10. ALL LEGAL EXITS SHALL BE PROVIDED WITH SELF - ILLUMINATED EXIT SIGNS HAVING 6" LETTERS WITH 3/4" STROKES IN CONTRASTING COLORS. HARDWARE CONTRACTOR ORDINATE ALL HARDWARE WITH DOORS & FRAMES AS SPECIFIED, INCLUDING STRIKES. 11. ALL MILLWORK IN THIS SCOPE OF WORK SHALL BE DELIVERED ON -SITE, SHOP- PRIMED AND SANDED. 12. ALL COMPONENTS OF FIRE RATED DOOR ASSEMBLES SHALL BEAR THE LABLEL OF AN APPROVED TESTING AGENCY INCLUDING DOOR, FRAME, CLOSING DEVICE, LATCHES & HINGES. FRAME AND PROVIDE SMOKE GASKETS AND DRAFT CONTROL IF REQUIRED. 13. DOOR HARDWARE SHALL BE OF THE LEVER OR PUSH TYPE (STAINLESS STEEL IN ALL LOCATIONS), MOUNTED 30" TO 44" ABOVE THE FLOOR AND SHALL BE OPERABLE WITH A MAXIMUM EFFORT OF 8.5 LBS FOR EXTERIOR DOORS AND 5 LBS FOR INTERIOR DOORS (KEY ALL LOCKS ALIKE). 14. OFFICE DOOR AND NON -SALES DOOR TO BE KEYED ALIKE. 15. FOR EXISTING SERVICE DOORS, G.C. TO INSTALL TAMPER PROOF HINGES IF NOT EXISTING, REMOVE OUTSIDE KNOB / LEVER / LOCK AND INSTALL BLANK COVER PLATES TO CONCEAL AI N C LE M P L E TE ;; I „... N : . - - ' N 1 I k � r apzezm W' tert.W.441W4•11 �'������i°� Fl = __ ,;. • °•• :., 0 /T fJ / J w1 wi e �� � - i .. R IEWED FOR I 0 I wi _ •• .�,� / \ lr -77 l/ // /W / / // f// /7 // 1 // // // '/' /7 ± 3' -2 1/4" o �� 5' -O” 10'4 1/2" 6'4 1/4" 6' - 8" / 12' f 9' -10" // 5' -0 1/4" /I 9' -10" 8' -10" 2' -7 1/4" / ENLARGED 1 RESTROOM X 12" / iCEN' Id SoulJ enter Mall A 98188 :ing Count A -6 DETAIL 0 OS CODE COMPLIANCE APPROVED �. 2006 . _ City Of Tukwila BUILDING DIVISION 0-7••-iiie&E, CONSTRUCTION PLAN SCALE: 1/4" = 11-0° N WALL TYPES DOOR STYLE DOOR SCHEDULE 5/8" GYP. BD. METAL STUDS ON 3 5/8" (20 GUAGE) DOOR NUMBER LOCATION SIZE DOOR MATERIAL FRAME DOOR TYPE HARDWARE GROUP REMARKS PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: W1 PARTITION WALL TYPE @ 16 "O.C' 001 STOREFRONT PR 3' -O" x 8'-O" GLASS METAL A 1 DD2 STORKROOM 3' -O" x 6' -8" S.C. WOOD WOOD B 2 :..•: : ..••...., ,......,.. - ::.. 003 UNISEX RESTROOM 3' -0" x 6' -8" S.C. WOOD WOOD B 3 SCALE: (DO NOT SCALE DRAWINGS) 6' - 0" 004 SERVICE DOOR 3' -0" x 6' -8" METAL METAL C 20 MINUTES RATED, STEEL DOOR AND FRAME. PROVIDE THE FOLLOWING HARDWARE: SCHLAGE D5OPD LOCKSET. VIEWER. NO OUTSIDE HARDWARE. LOCKGUARD. 3' -0" 3' -0" OR SIDES) STUDS (20 SEE DETAIL ATTACH) 5/8" GYP. BD. ON 3 5/8" METAL WALL TYPE GUAGE) @ 16 SCHEDULE. (BOTH "D.C. „0 'r f f / 0 0 1 / SHEET TITLE: CONSTRUCTION CONSTRUCTION PLAN RECEIVED CITL�s ,� ± ate JAN 2 2 ''"' -zs;;r I ;�K�s I e:_ \ \ / HARDWARE GROUP II .. a I GROUP 1: GROUP 2: GROUP 3: LTR# ii /` • i 2 EA. CYLINDER DEADBOLT BEST 7 -PI CYLINDER 1 EA. LOCKSET SCHLAGE AL5380 SAT 626 2 3/4" BACKSET w /BEST 7 -PIN ADAPTER, INTERCHANGEABLE CORE AND KEY 1 EA. LOCKS 7-PIN A E AL50PD SAT 626 2 3/4" BACKSET w /BEST 7 -PIN ADAPTER, INTERCHANGEABLE CORE AND KEY, PRIVACY LOCK .. .. 1 EA - ADAMS RITE MS -1850, ADAMS RITE 3 POINT 4015/4085 SILVER 3 EA. HINGES HAGER BB1279 41/2"x4 1/2" US26D 3 EA. HINGES HAGER BB1279 4 1/2 "x4 1/2" US26D PARTITION - MO � W2 1 EA. EXTENSION FLUSH BOLTS (RUSTPROOF AT FLOOR), PROVIDED BY STOREFRONT MANUFACTURER, SILVER 1 EA. CLOSER LCN 4011 ALUM (PULL SIDE MOUNTED) 1 EA. CLOSER LCN 4011 ALUM (PULL SIDE MOUNTED) � ,-- 3 EA. HINGES BB1279 4- 1/2 "x4 -1/2" 1 EA. DOOR STOP DON JO 1450 -626 or TRIMCO 1231 626 OR VIES PS446 US626 1 EA. DOOR STOP DON JO 1450 -626 or TRIMCO 1231 626 OR VIES P5446 U5626 A._ i \ \ \ 10" HIGH S.S. 12" HIGH S.S. A. B. C. KICKPLATE, KICKPLATE, BOTH SIDES BOTH SIDES 2 EA. MAGNETIC HOLD OPEN RIXSON MODEL #990 WALL AND DOOR MOUNT HOLD 1 EA. SILENCERS GLYNN- JOHNSON GJ64, GRAY FINISH, 3 PER DOOR LEAF 1 EA. COAT HOOK McKINNEY 1043Z, MOUNT AT 48" A.F.F. 2 EA. DOOR PULLS w /PUSH PLATES ROCKWOOD RM- 4020 -16 ARBORMET ROUND WOOD GRIP PULLS 1 EA. KICK PLATE 12 "x36" S.S. KICK PLATE 1 EA. SILENCERS GLYNN- JOHNSON GJ64, GRAY FINISH, 3 PER DOOR LEAF SEE DETAIL 5/A FOR -13 ATTACHMENT SCHEDULE. 2 EA. CLOSER ...._.."___.----___/4.----' GENERAL NOTES A. REFER TO GENERAL NOTES ON SHEET G -1 B. CONTRACTOR TO ENSURE DELIVERY AND INSTALLATION OF CASEWORK AND FINISH CARPENTRY WILL NOT BE DAMAGED BY OTHER CONSTRUCTION WORK. NOTES: DEMISING WALLS ARE NOT DESIGNED TO SUPPORT MERCHANDISE OR FIXTURING. WALL FIXTURE LOADS MUST BEAR ON AN INDEPENDENT FIXTURE PARTITION INSTALLED ADJACENT TO THE DEMISING WALL. PERMIT IS REQUIRED FOR ALL STORAGE RACK MORE THAN S' -0" IN HEIGHT. NO RACK IS ALLOWED 12' -0" OR HIGHER. VERIFY WITH FIRE MARSHALL WHETHER SIDE SLIDING STOCK ROOM SHELVING WILL BE ALLOWED SINCE FIRE PROTECTION LANDLORD'S SPRINKLER SYSTEM IS DESIGNED FOR ORDINARY HAZARD GROUP 2. G.C. TO VERIFY LOCATION AND GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESTFIELD'S ON SITE TENANT COORDINATOR BEFORE PROCEEDING WITH WORK. NO PEDESTAL SECURITY SYSTEMS WILL BE ALLOWED. UNDER FLOOR TYPE WILL BE ACCEPTABLE. �041111111 4 �\ \ 4 A ---- 1.. ` `1 KEY NOTES LEASE LINE, V.I.F. V EXISTING 6" DEMISING DEMISING STUD WALL BY LL TO REMAIN, U.O.N. G.C. TO PROVIDE 5/8" TYPE "X" GYP. BD. ON TENANT SIDE. MAINTAIN FIRE RATING. 3O EXISTING NEUTRAL PIER 0 EXISTING STRUCTURAL COLUMN TO REMAIN NEW MIRROR(S) @ WALL MOUNTED LCD TV O CASEWORK PROVIDED AND INSTALLED BY CASEWORK VENDOR, TYP. CASEWORK VENDOR TO PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL BY DESIGN FIRM PRIOR TO FABRICATION. ® CASEWORK VENDOR TO VERIFY DIMENSIONS IN FIELD PRIOR TO FABRICATION OF CASEWORK. 10 SHELVING 0 OFFICE BUILT -IN DESK 13 NEW TELEPHONE BACK BOARD 15 SOFFIT ABOVE 0 PROVIDE WATER PROOFING IN RESTROOM LIP TO 12" UP THE WALL. R EE CODE COMPL • _ i _ ei , ---- Cit------------__AFFPRP7.11:::::: I B =LDIN D .. ® • • • \•: 7 � r1 ■ ■ associates ARCHITECTURE INTERIORS PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 Fx:415 -362 -5044 BARE E S C E N T U A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 0 0 J (E) SERVICE CORRIDOR 0 W THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AN D /OR USE OP THESE MATERIALS (OR ANY PORTION OF THEMI WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. . k �i ' I 1I, 7AUtiP1 �� r � � �1 �' �* a & I III I = 101 � 0 0 I, iI FW ■ illtil 0 ® 0 ■ (1-;1 1)1 WA LS 08 %WilI IF REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 0 01/09/08 PCC SET A k 3' - 0" i ` y "I I � o,� TYP SALES I " I r d W. ; WAW..,� (FT24) I. MB STOCKROOM O24r.X (M$) �� op Ls DB MIED 1 �`' 0 11 7 ?28 AMMO OHAZAB ATE OF '' HlNGTON %di D B 0 Kf [If N1A TYP. / iiv ` ` 1 i CDV C 1 I ' r ' II `,f∎'. ° o I 011 e _ 0 C . � i YAl � 0 (FT24) 0 ® CEP FT24 a, i L , iU. (iU^ cm 1 I li 0 I OO © TYP. Cf f I?f NIA � ) H.C. RES NISEX ROOM 11 Ao lla EMI 1 0 Fw I (WU) � �� ri 40 (WU) IT ® ® I wU WU w U 217/1 �.m/� �.ayArms ��'' :l 1 it .e . . lam. l �, NIAMIN 17i PAINT iI.d J 0 FIXTURE PLAN 0 GI N Souti ter Mall 98188 g Count SCALE: 1/4" = 1' -0" EQUIPMENT SCHEDULE NUMBER DESCRIPTION DETAIL COMMENTS NUMBER DESCRIPTION DETAIL COMMENTS o.,..... '( OF T I I �( OF TI N6 � nFi� A JAN 22 rn3 FI.:d 'v'al I (.;EN) ER PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: WALL CABINET BY MILLWORK VENDOR, INSTALLED BY G.C. DESK AND CHAIR - BY OWNER (wu) ( 014) WALL CABINET - BY MILLWORK VENDOR, INSTALLED BY G.C. FILE CABINET / PRINTER - (Wu -1) ( 015 ) WALL CABINET WITH CREDENZA ( 60" ) - BY MILLWORK VENDOR, INSTALLED BY G.C. EMPLOYEE LOCKERS - (WU -3) CM SCALE: (DO NOT SCALE DRAWINGS) WALL CABINET WITH CREDENZA ( 72" ) - BY MILLWORK VENDOR, INSTALLED BY G.C. ELECTRICAL PANEL - (wU -5) 017 ) WALL CABINET - BY MILLWORK VENDOR, INSTALLED BY G.C. TELE' - ! 6. E PANEL _ - (WU -6) 018 ��� SHEET TITLE: FIXTURE PLAN LAZY SUSAN ( 044" - 8 DRAWERS ) - BY MILLWORK VENDOR, INSTALLED BY G.C. . MICROWAVE •■ - BY OWNER (LS DS) ( 019 ) MAKE -UNDER COUNTER - BY MILLWORK VENDOR, INSTALLED BY G.C. REFRIGERATOR - BY OWNER ( MB ) 020 CDV CASH DESK FEATURE TABLE (024 ") - _ BY MILLWORK VENDOR, INSTALLED BY G.C. BY MILLWORK VENDOR, INSTALLED BY G.C. DRINKING FOUNTAIN HIGH -LOW - OASIS PR8ACSL - BARRIER -FREE SPLIT -LEVEL VERSACOOLER II WATER COOLERS CDV 021 (FT24) FEATURE TABLE ( 036" ) _ BY MILLWORK VENDOR, INSTALLED BY G.C. (FT36) FOCAL WALL _ BY MILLWORK VENDOR, INSTALLED BY G.C. ® A.2 LUCITE TABLE WALL MTD. FRAMED LCD TV _ - BY MILLWORK VENDOR, INSTALLED BY G.C. BY MILLWORK VENDOR, INSTALLED BY G.C. ( LT ) C B STOOL CASH REGISTER - - BY OWNER BY OWNER ( 007 ) ( 011) GENERAL NOTES NOTES: ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE CONCEALED POP OF COVER TYPE. ALL SUPPORTS TO BE FROM STRUCTURAL BEAMS AND JOISTS AND NOT FROM DECK ABOVE. ALL STOREFRONT LIGHTING MUST BE INCANDESCENT AND ON SEPARATE CIRCUIT AND ON 7 DAY TIME CLOCK SET TO MALL'S OOPERATING HOURS. STOREFRONT SIGNAGE MUST BE ON SEPARATE CIRCUIT AND ON 7 DAY TIME CLOCK SET TO MALL'S OPERATING HOURS. THERE MUST BE GYP. BD. CEILING WITHIN THE FORWARD SELLING AREA. CEILING SUPPORT SHALL COMPLY WITH ANY SEISMIC BRACING REQUIRED PER LOCAL CODE. VERIFY WITH FIRE DEPT. ON STOCK ROOM SHELVING HEIGHT AND CLEARANCE FROM TOP OF SHELVING TO SPRINKLER DEFLECTOR SHEILD. t REFER TO GENERAL NOTES ON SHEET G -1. 2. ALL NEW FLUORESCENT BALLASTS AND LAMPS, SHALL BE SYLVANIA COMPATIBLE. 3. ALL NEW FLUORESCENT LAMPS SHALL HAVE A COLOR RENDITION OF 3000K. 4. ALL NEW LIGHT FIXTURES ARE TO RECEIVE NEW LAMPS. 5. NOT USED 6. DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A LATERAL FORCE OF 20% OF THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM. USE A MINIMUM CEILING WEIGHT OF 5 POUNDS PER SQUARE FOOT TO DETERMINE THE LATERAL FORCE. 7. WHERE CEILING LOADS DO NO EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING METHODS MAY BE EMPLOYED: A. PROVIDE LATERAL SUPPORT BY FOUR WIRES OF MINIMUM NO. 12 GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREES APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. B. ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT TWO ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT THE OTHER TWO WALLS. C. PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES. IN ADDITIONAL, VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8" OF DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING IS INTERRUPTED BY A WALL. D. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. 8. ALL CEILING HEIGHTS INDICATED ON PLAN ARE FROM TOP OF FINISH FLOOR TO UNDERSIDE OF FINISH CEILING, U.O.N. 9, NOT USED. 10. PROVIDE ADEQUATE CLEARANCES FOR FIXTURES, DUCTS, CEILINGS & RELATED APPURTENANT ITEMS NECESSARY TO MAINTAIN THE SPECIFIED HEIGHT ABOVE FINISHED FLOOR. 11. ARCHITECTURAL DRAWINGS DETERMINE THE LOCATION OF LUMINARIES & SUPERSEDES ALL OTHER DRAWINGS, UO.N. 12. SEE ELECTRICAL DRAWINGS FOR FIXTURE MODEL NUMBER. 13. ALL LIGHTING FIXTURES PROVIDED BY OWNER & INSTALLED BY SUBCONTRACTOR, U.O.N. 14. LATERAL BRACING FOR CEILING MUST BE PROVIDED. (U.B.C. 88, TABLE 23P), WHERE CEILING LOADS ARE LESS THEN 5PSF & NOT SUPPORTING INTERIOR PARTITIONS. CEILING BRACING SHALL BE PROVIDED BY FOUR NO. 12GA. WIRES SECURED TO THE MAIN RUNNER INTERSECTION & SPAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE LESS THAN OR EQUAL TO 45 DEGREES FROM THE PLANE OF THE CEILING. THESE HORIZONTAL RESTRAINT POINTS SHALL BE 15. ADDITIONAL HANGERS & SAFETY WIRES FOR LIGHT FIXTURES, SPEAKERS & AIR SUPPLY /RETURN DIFUSERS (SEE LOACAL CODES), TO BE THE RESPONSIBILITY OF THE CEILING SUBCONTRACTOR. 16. PROVIDE ACCESS PANELS AS REQUIRED BY CODE COORDINATE LOCATIONS PER LOCAL CODE E, SIGN LOCATIONS, AND REQ'D BY LANDLORD. 17. ALL GYP. BD. CEILINGS TO BE SMOOTH FINISH &PAINTED P -4, U.O.N. • �■1111111n4IN ilk —_ ■ )III 4 4'Iral • • • V r ` \ r � i� �y1 1 III ' associates ARCHITECTURE INTERIORS PLANNING I 2747 19th STREET SAN FRANCISCO. CA 94110 PH: 415 -362 -5857 FX: 415 -362 -5044 BARE E S C E N T U A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 ■ (N) GYP. BD. CLG. @ 9' -0" A.F.F. ACT (la 9' -0" A.F.F. PAINT TO I PERIMETER CROWN MLDG., TYP, PAINT MATCH (E) SERVICE CORRIDOR P -1 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION. MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ADJACENT CORRIDOR CEILING FINISH EQ. EQ. EQ. EQ. 3 FIXTURES 3 FIXTURES ED. @ 3'-2" 0.C. EQ @ 3' -2" 0.C• EQ EQ 3' -2" EQ © 111 =I �■ _ l %WAN : � C_ 1 I i % q REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 PCC SET , �.. _ -� "' t6 NE0 p + 1 -I- ::.:.:::::.::::<:.......:..::: I it 3' FC IN . w `� ( 0 TYP. TYP. GYP. BD. CLG. @ 6 A.F.F. PAINT Ila'�.d�� O ' +.- I I i, EQ , -2" EQ L I P -4 �' - E' €f1 I � , 1 ` # I I 0 I I I p PI r U I,_ . 03 ` - 6 .THE f I O $ F B1 s FBBC - - - ^ te FB .FB FB ¶ FBSAL E S - FB B • Z „8 REU` T ' 4 AMMO )tiAZAB - S HIN I OF GTON X. 0% • ... 1 Of / STOCKROOM r .,wrr .�Mr�wr _.; I I =F 12" ! • F G F F F G F F C : _;: F F f F E. rn FS F F FG FC FG C G FG F C F FG F C C FG F F F ' •® I,-, Mg �..;. . B • I: :_:.:. FBI -- - a �I 'G * .: � i *: �< _..: • 1 WOOD CLG. @ 11' -0” A.F.F. PAINT p I P -1 I .I � �/ NEI - - - - - ` ., - ' V FB1 - }; FB1 .: .FBI F BI Fla • I - FC - "- e } ® a a '' a ` " 01111 iirorxdormseraTillilliak .. 1 2' 1 2 12' 12' 2 1 ' 12' : . 1 2 " 12" 1 2' 12' p z' FC EQ GYP. BD. 10'_6" A.F.F. PAINT - " • I ' FBI I P -1 KEY NOTES � i 03 FB I— FB�1 a % ` FG . ` FB1 --- . FG FBI " - " - , : • F81 : FBI ,�. y� i a - �' 0 FG F? FG - _ F` FG I F G FG FG FG FG FG .P+ FG F F.. " FG FG a FG FG FG FG '1.. Ft TYP. NEW MILLWORK, SHOWN DASHED FOR REFERENCE ® LEASE LINE FLUORESCENT FIXTURES ABOVE MILLWORK SHELFING UNITS 6 WALL MOUNTED SCONCE. DEMISING WALL. V PROVIDE ACCESS PANELS AS REQUIRED FOR ACCESS TO LANDLORD'S/TENANT'S COORDINATE WITH MALL REPRESENTATIVE. 9 CEILING MOUNTED SPEAKERS 10 WALL SCONCES 11 CEILING MOUNTED DISPLAY FIXTURE 12 CHANDELIER F�E �i�V� r—;FirCE ! R E COMP! (N) GYP. BD. CLG. _ " - " - " -" - " " � ;' -- -- - - - - - T e _ ` - I F : : -F }BB j 0 FB • FB _ : B y -- FB ::.FB :�. - G a F & 1 �r N y ' i ; "' GYP. BD. CLG. @ 15'4" A.F.F. @ 9' 0" A.F.F. T TYP„,„. B.1 � FB :.:F.B 6 PAINT �.- �: a PAINT � i :: I P -25G I H.C. UNISEX fR V A _ TYP. TYP. ,. o o Q Q I� I Y T Q O D O P -1 c 1 ,� l °4-1 ,•r ! a O L 4' �74 P7 * • �� �r ' e ,� •' ' :' o ^' b` c) .. • O 111111■ �. / ■� ____ ��,�',i �A.'� /,�',�V.R /. Ir i /1 '. /! / / EQ. EQ. 1' - 8" I i- 7 / I EQ 3 FIXTURES @ 3' -2" O.C. EQ EQ EQ EQ ,> 3 FIXTURES @ 3' -2" O.C. EQ I O © Soul iter Mall 98188 Coun 3' -2" 12 / COFFERED CEILING / LIGHT DETAIL / �f /-,/ f , A -13 N PERIMETER CROWN ML., TYP, MUM., j 1 a P IN I P P APPROVED REFLECTED CEILING PLAN FEB - 1 2 City Of Tukwila B ILDING D, ,/ SCALE: 1/4" = V -0" FIXTURE LEGEND REFLECTED CEILING SYMBOLS PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: FA RECESSED MULTI -LAMP CERAMIC HALIDE ACCENT (21x39W FF • RECESSED ADJUSTABLE ACCENT W/ 1 - 37 WATT MR16 (1)x37W EM 2 HEADED EMERGENCY LIGHT N/A SYMBOL DESCRIPTION SYMBOL DESCRIPTION t� E CEE ") �) TI i; "e� Q JAN 22 rl Ft� iVA I UE I E9 [._.� FB RECESSED ADJUSTABLE ACCENT CERAMIC HALIDE 39W (1)x39W FG c - LINEAR FLUOR. STRIP 1 x 32 WATT T8 LAMP (11x32W DC M CHANDELIER (9)x25W (1)x59W OD DIMENSION OF CEILING ABOVE FINISH FLOOR O THERMOSTAT SCALE: (DO NOT SCALE DRAWINGS) FG1 FG2 LINEAR FLUOR. STRIP 1 x 25 WATT T8 LAMP LINEAR FLUOR. STRIP 1 x 17 WATT T8 LAMP (1)x25W (1) x17W CEILING FINISH LIGHT SWITCH F61 RECESSED ADJUSTABLE ACCENT CERAMIC HALIDE 39W (1)x39W I WALL EXIT FACE(S) AND I OF ARROWS) QUALITY OF 1J DIMMER SWITCH FC 0 RECESSED COMPACT FLUOR. DOWNLIGHT W/32 WATT PLT LAMP (1)x32W , // A 2'x4' FLUORESCENT FIXTURE SHEET TITLE: REFLECTED CEILING PLANS AND SCHEDULE ® I FA CEILING MOUNTED EXIT SIGN, SHOWS QUALITY OF C 1 1 AND DIRECTION OF FACE (S) ARROW(S) RETURN AIR FH SURFACE MOUNTED LED STRIP LIGHT BUILT INTO MILLWORK ASSEMBLY (1)x8.4W FC1 O� RECESSED COMPACT FLUOR. SINGLE WALLWASH W/32 WATT PLT LAMP (1)x32W SD SMOKE DETECTOR SUPPLY AIR Fl LINEAR FLUOR STRIP UNDER - CABINET TASK LIGHT (1)x32 W 51 S1 SPEAKER - BOSE M16 N/A ■ d FC2 <0> RECESSED COMPACT FLUOR. DBL. WALLWASH W/32 WATT PLT LAMP (1)x32W ST STROBE O CIRCULAR SUPPLY DIFFUSER FK SURFACE MOUNTED LED STRIP LIGHT BUILT INTO MILLWORK ASSEMBLY (1)x8.4W S2 S2 SPEAKER - KLIPSCH N/A FD W/ 1 37 WATT MR 6 LE ACCENT (1)x37W FIRE SPRINKLER HEAD - SEE MECH. EF EXHAUST FAN O FL FLUOR. CIRCULINE LAMP BUILT INTO MILLWORK DISPLAY (6)x5W /Ft. DB (3)x25W "...._ _ . WALL SCONCE SPEAKER E DENOTES EXISTING TO REMAIN A.4 FD1 RECESSED ADJUSTABLE ACCENT W/ 1 - 37 WATT MR16 (1)x37W FM LINEAR FLUOR. STRIP 1 x 32 WATT T8 LAMP (1)x32W J WALL MOUNTED FLUORESCENT (1)x17W ACCESS DOOR R DENOTES EXISTING, RELOCATED FIXTURE Q STRIP LIGHT FM1 ° LINEAR FLUOR. STRIP 1 x 25 WATT T8 LAMP (1)x25W DA O PENDANT LIGHT FIXTURE (11x26W I LINEAR DIFFUSER FE LINE VOLTAGE TRACK SYSTEM SURFACE MOUNTED IN GYP. SLOT FM2 LINEAR FLUOR. STRIP 1 x 17 WATT T8 LAMP (1)x17W GENERAL NOTES FINISH NOTES: EXTEND EXISTING MALL TILE AT LEASE LINE TO TENANT'S STOREFRONT BASE AND ALSO INTO VESTIBULE TO UNDERSIDE OF DOOR. TILE TO MATCH EXISTING MALL TILE IN TYPE, COLOR, SIZE, THICKNESS, GROUT COLOR AND INSTALLATION DIRECTION. NO THRESHOLD REDUCER STRIP OR OTHER WIDE TRANSITION DEVICES WILL BE PERMITTED AT INTERSECTION TO TENANT'S FLOORING AND MALL TILE. WHEN EXTENDING MALL TILE INTO TENANTS STOREFRONT BASE OR VESTIBULE, TILES MUST BE FULL TILE. IF TILE IS CUT, IT MUST BE REMOVED AND REPLACED WITH FULL TILE. SUBMIT COLOR AND MATERIAL SAMPLE BOARD FOR LANDLORD REVIEW AND APPROVAL. ALL COLOR AND MATERIAL SELECTIONS MUST MEET ALL CODE REQUIREMENTS FOR FLAME SPREAD AND SMOKE DEVELOPMENT FACTORS. SUBMIT CUT SHEETS OF ALL INTERIOR FINISHES AS REQUIRED. PROVIDE CERAMIC TILE FLOORING IN RESTRDOM OVER WATERPROOFING MEMBRANE TO A MIN, 12" UP 1 HL WALL. INS f ALL LANDLORD APPROVED LA I EX RUBBLR WA 1 ERPRUUF NJ MATERIAI UNDFR THF FE. FINISH, THF MEMBRANE SHALL BE MANUFACTURER'S 2 PART FORMULA CONSISTING OF LIQUID LATEX RUBBER AND POWDER FOR TROWEL APPLICATION WITH GLASS FIBER FABRIC REINF URCEMEN 1 (LA 11CRE 1 L 923 UR SUMM1 I VILLL 5 - 9000), INSTALL A WATER TIGHT DOOR THRESHOLD, BUILDING NOTES: THE FLOOR ON BOTH SIDES OF ALL DOORWAYS SHALL BE SUBSTANTIALLY LEVEL AND SHALL HAVE THE SAME ELEVATION ON BOTH SIDES OF THE DOORWAY FOR A DISTANCE AT LEAST EQUAL TO THE WIDTH OF THE WIDEST LEAF, PER SECTION 7- 2.1.3.2, NFPA 101. INTERIOR FINISH (IE: WALLS, CEILING TILE, ETC.) SHALL HAVE A FLAME SPREAD RATING OF 200 OR LESS WITH A MAXIMUM SMOKE GENERATION FACTOR OF 450 PER SECTION 10.2, NFPA 101. A. REFER TO THE GENERAL NOTES ON SHEET G -1. B. TRANSITION OF FLOOR MATERIALS TO BE LOCATED AT THE CENTER OF DOORS IN CLOSED POSITION, UNLESS OTHERWISE NOTED. C. CONTRACTOR TO ENSURE DELIVERY AND INSTALLATION OF CASEWORK AND FINISH CARPENTRY WILL NOT BE DAMAGED BY OTHER CONSTRUCTION WORK. D. ALL INTERIOR WALL SURFACES MUST BE FINISHED IN AN APPROPRIATE MANNER AND BE IN COMPLIANCE WITH ALL APPLICABLE CODES. ALL TENANT SPACE INTERIOR WALL FINISHES ARE TO MEET A CLASS III FLAME SPREAD RATING. FINISH WOOD AND TRIM NEED NOT BE FIRE- RESISTANT, BUT SHALL MEET CLASS III. CERTIFICATES OF COMPLIANCE ARE NECESSARY FOR INTERIOR FINISHES. E. WOOD USED IN THE CONSTRUCTION OF THE STOREFRONT MUST BE KILN DRIED, MILL QUALITY HARDWOOD AND MUST MEET LOCAL FLAME SPREAD REQUIREMENTS (CLASS III 76 -200). F. PAINTED WOOD MUST HAVE A SHOP QUALITY ENAMEL FINISH. ■ �.04111 �\ .1 )1 4 ' \ `� , 2 _jr, ® • • • \ V 1 \I� '� yam' — ® Qp�+ associates ARCHITECTURE INTERIORS PLANNING KEY �+ KE i NOTES 0 LEASE LINE, V.I.F. ZO NEW CASEWORK, SHOWN DASHED, TYP. O EXTEND EXISTING MALL TILE FROM LEASE LINE INTO VESTIBULE TO UNDERSIDE OF DOOR ALSO EXTEND FROM MALL TILE LEASE LINE TO FACE OF STOREFRONT BASE TILE. REFER TO FINISH NOTES FOR ADDITIONAL INSTRUCTIONS. 04 FINISH WALLS, FLOOR AND CEILING IN REAR DOOR ALCOVE TO MATCH (E) SERVICE CORRIDOR FINISHES. 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415-362-5857 FX: 415-362-5044 BARE ESCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 0 0 "" (E) SERVICE CORRIDOR j THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME BARE ESCENTUALS. ANY REPRODUCT ON, AT ON, DISCLOSURE OF AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. MI iimod 6 Ii i r r _ __ __- _ ._l %J' 16 ' '� ' L i " ''*'°•A /211116f$ © � 10 REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 PCC SET ma i r "' "- ATE OF W � `i '� e GM ® STOCKROOM P -2 E5 SALES P .5 WC -3 B - 1 f B - 1 P -2 E5 P -3 P -2 E5 B - 1 B - 1 B - 1 rf O / a 0 P -2E5 B -3 VT -1 \ 0 ® ®. ®arr r . WD -1 WD -1 P -3 •:: \ �/ w , P -2 ES P P -2 ES H.C. UNIS RESTRO M -3 WC -3 P -5 WC - 1 I Southcenter iter Mall 98188 lg County P - 2SG CT -1 e'rAwnswira , 4,.., . . wai . rAP3417-4. 0 4 .....0 /r in �Al/�lI/ /Ir��d//// / / /��// �A/ /TAI FINISH PLAN 0 . REVIEWED FOR CODE COMPLIANCE APPROVED FEB - 1 2 I SCALE: 1/4" = 1' -0" ROOM FINISH SCHEDULE City Of Tukwila 1; ,T ' 1 KEY MATERIAL i MANUFACTURER TYPE COLOUR/PRODUCT # i INTERIOR SW #7102 "WHITE FLOUR" _...... ... _ I INTERIOR I SW #6603 "OLEANDER" INTERIOR i SW #6603 "OLEANDER" INTERIOR i SW #6862 "CHERRIES JUBILEE" INTERIOR i 5W #6609 "TOUCHING WHITE" - � INTERIOR I SW #6112 "BISCUIT" MATCH MALL FLOORING FROM STOREFRONT CLOSURE TO LEASE LINE AT ENTRY I - 5/8" X 3 1/2" VALENZA COLLECTION / ENGINEERED € #PR422NA PRAD00 NATURAL _._......_.__.._.._.......__.._ VINYL COMPOSTION #51899 COOL WHITE TILE i SHEET VINYL w /INTEGRAL COVE BASE 6" i #88213 WHITE SAND : I ( 6" HIGH i - i CALACATTA GOLD 4" HIGH 1/8" GAUGEµ I #69 "LIGHT GREY" COLOR-INTEGRATED - i - ... �.... SELF ADHERING VINYL i CUSTOM SWIRL, TAP, BUFF IMAGE WALL PAPER £ XXL (N0. TP 121 01) _ _.. _.. �. WHITE / PEBBLE FINISH I - SIZE FINISH LOCATION STOREFRONT / SALES AREA BASE / C. RO, W.N. M41. 01. N. Fa .. /...5T13�.KRO.OM..l...1 L!NISEX„ IL.ET WALLS - SALES AREA / STOCKROOM WALLS / CEILING RESTROOM ACCENT WALLS - CASH WRAP /SALES AREA CEILING /SALES AREA FOCAL WALLS ENTRY VESTIBULE - COORDINATE WITH MALL REPRESENTATIVE SALES FLOOR OFFICE H.C. UNISEX TOILET SALES AREA STOREFRONT BASE OFFICE STOREFRONT WINDOW RESTROOM FLOOR AND BASE SALES AREA - TV WALL SALES AREA - FOCAL WALL H.0 UNISEX TOILET WAINSCOT /SERVICE SINK CONTACTIREMARKS - _ _ 1877 ARMSTRONG MARY BELLE MCMACKIN 618- 288 -6794 PATTY ROSE 1- 800 - 347 -0550 EXT 821 SANDY 1- 818 -842 -1121 ___._ - _ - y CITY OF - F ;p. °•'�I - A JAN 22 ?"3 JAN 2 3 J FIRI'mi I (..;N I is I P -1 PAINT 1 SHERWIN WILLIAMS _ SEMI -GLOSS - EGG SHELL - SEMI -GLOSS - EGG SHELL _ FLAT - EGG SHELL 5/8" POLISHED _ 54" - - POLISHED N - _ - - ._ - CUSTOM SIZE _ CUSTOM SIZE - .__ .. , m PAINT s SHERWIN WILLIAMS PAINT I SHERWIN WILLIAMS I PAINT i SHERWIN WILLIAMS PAINT SHERWIN WILLIAMS IP-2 E.S•I IP-2 S•G•I I P-3 PROD. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: I 4 I P -5 PAINT SHERWIN WILLIAMS ! I MALL TILE T.B.D. i WOOD FLOORING HARTCO BY ARMSTRONG . _ _._....__ VINYL FLOORING ARMSTRONG VINYL FLOORING ARMSTRONG MF -1 I SCALE: (DO NOT SCALE DRAWINGS) WD - 1 I VT -1 I SHEET TITLE: FINISH PLAN AND SCHEDULE f SV -1 I I SUPERIOR MOULDING - B -1 I WOOD BASE i ryry MB -35 -b0 I B - 2 B I MARBLE FLOORING / BASE i SOUTHLAND STONE B -3 I VINYL BASE i ARMSTRONG .... ...... ..... ....... F -1 I FABRIC CURTAIN BY OWNER I CT CERAMIC TILE - CALL SANDY 1- 818 -842 -1121 DONGHIA INC. CONTACT: KITTY 415 -861- 7717x201 FROM TOP OF COVED BASE TO 48" A.F.F. '_.._ I WC - I WALL COVERING i CRUSH CREATIVE WC -3 I WALL COVERING ELITIS � .. .............. - i - I FIBER REINFORCED FRP I MARLITE POLYESTER NOTES: PROVIDE CERAMIC TILE FLOORING IN RESTROOM OVER WATERPROOFING MEMBRANE TO A MIN. 12" UP THE WALL. INSTALL LANDLORD APPROVED LATEX RUBBER WATERPROOFING MATERIAL UNDER THE FLOOR FINISH. THE MEMBRANE SHALL BE MANUFACTURER'S 2 PART FORMULA CONSISTING OF LIQUID LATEX RUBBER AND POWDER FOR TROWEL APPLICATION WITH GLASS FIBER FABRIC REINFORCEMENT (LATICRETE 9235 OR SUMMITVILLE 5- 9000). INSTALL A WATER TIGHT DOOR THRESHOLD. P -2 S1 ■ 18" CT -1 A UNISEX HC RESTROOM ELEVATIONS SCALE: 1/4" = 1' -0" SIGNAGE IS TO COMPLY WITH IBC 1103.2.4 FOR LOCATION & 110616 FOR DESIGN NOTE: SIGNAGE SHALL BE 1 4" THICK & THEIR COLOR & CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THAT OF DOOR H.C. ACCESSIBILITY SYMBOL PAPER TOWEL DISPENSER ENLARGED UNISEX HC RESTROOM PLAN 01) SCALE: 1/2" = 1' -0" N j 12" HAND DRYER UNISEX SIGNAGE COMBINATION TOWEL AND WASTE DISPENSER i ommew Aranomed // 111 • wAi P I 48" L 1-6 " 1-6" 60" 56" 4 i m MISC. HEIGHT REQUIREMENTS TOILET SEAT COVER DISPENSER NAPKIN DISPENSER F.F TRASH 5' -0" SIGNAGE LOCATION TOILET ROOM DOOR THERMOSTAT 1 LJ RECEPTACLE SWITCH TOILET ROOM SIGNAGE BRAILLE FIRE ALARM OR HEAD OF FIRE EXTINGUISHER CUP DISPENSER CLEAR FLOOR SPACE LAVATORY URINAL TYPICAL HANDICAP TYPE LEVER TO BE USED GENERAL NOTES 1. GRAB BAR: LOCATE GRAB BARS ON EACH SIDE OF WATER CLOSET OR ONE ON SIDE AND ONE BEHIND WATER CLOSET. SIDE GRAB BARS ARE TO BE 3' -6" LONG WITH THE FRONT END 2' -0" IN FRONT OF WATER CLOSET. GRAB BARS AT THE BACK CANNOT BE LESS THAN 3' -0 ". GRAB BARS SHALL NOT ROTATE AND THERE ARE TO BE NO SHARP OR ABRASIVE ELEMENTS ON OR ADJACENT TO THEM. EDGES ARE TO HAVE A MINIMUM 1/8" RADIUS 2. SIGNAGE; IDENTIFICATION SYMBOLS. DOORWAYS LEADING TO MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE 1/4" THICK W/ EDGES 12" LONG AND A VERTEX POINTING UPWARD. WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 1/4" THICK AND 12" IN DIAMETER. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK, 12" IN DIAMETER W/ A 1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12" DIAMETER. THESE GEOMETRIC SYMBOLS SHALL BE CENTERED ON THE DOOR AT THE HEIGHT OF 60" AND THEIR COLOR AND CONTRASTS SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRASTS OF THE DOOR ALSO PROVIDE PERMANENT SIGNS IN RAISED (1/32 INCH MINIMUM) LETTERS OF SANS -SERIF UPPERCASE CHARECTERS ACCOMPANIED BY GRADE -2 BRAILLE. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT SHALL BE 60" A.F.F. TO THE CENTERLINE OF SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF DOOR. 3. LAVATORIES: 2' -10" IS THE RECOMMENDED HEIGHT FROM THE FLOOR TO THE TOP OF THE LAVATORY. INSULATE OR COVER ALL HOT WATER AND DRAIN PIPES UNDER LAVATORY. NO SHARP OR ABRASIVE EDGES ALLOWED UNDER LAVATORY. 4. GENERAL: FAUCET CONTROLS AND OPERATING MECHANISMS MUST BE EASILY OPERATED BY ONE HAND AND MUST NOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE NEEDED TO ACTIVATE CONTROLS SHALL NOT EXCEED 5 LBS. FOR LEVER OPERATED OR 15 LBS. FOR PUSH TYPE 5. REFER TO SHEET G -2 FOR RESTROOM ADA REQUIREMENTS. KEY NOTES 10 NEW DOOR AND FRAME • 18 "x36" TILT MIRROR BY BOBRICK B -293 4@ 36" GRAB BAR BY BOBRICK B- 6806x36 O TOILET TISSUE HOLDER BY BOBRICK B -2740 © 42" GRAB BAR BY BOBRICK B- 6806x42 O7 18" VERTICAL GRAB BAR BY BOBRICK B- 6806x18 ® TOILET SEAT DISPENCER (SURFACE MOUNTED) BY BOBRICK B -221 9D TOWEL DISPENCER (SURFACE MOUNTED) BY BOBRICK B -253 11 TOILET - ADA COMPLIANT 12 ARTEMIDE 560 24" ALUMINUM FLOURESECENT STRIP FIXTURE 14 LAVATORY - ADA COMPLIANT SEE LANDLORD REQUIRED NOTES ON SHEET T -1 REGARDING WATERPROOF MEMBRANE IN WET AREAS. REVEWE CODE COMPLIANCE APPROVED FE 3 2008 �JT y. � o Te� ja iLDING D R.SION CITY Of TUK�/ILA DEC 19 2007 PERMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 -362 -5857 FX: 415- 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 718 R • A AI M E OF W STEREG' HI cs 0 N 0 CO C CO Ca C 0 oes C) a) Z 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: ENLARGED UNISEX HC RESTROOM, ELEVATION A -6 EQ. EQ. r EQ.— . ' EQ. / Ea. OTYP. OTYP. 1 EQ. EQ. / Ilr 0 WC - I -3 II 1 / / I BARE ESCENTUALS Din 4/ O n n n n n n n n_ n n nEQ. 1EQn fl n ECl EQ - IN \ �1 1 I n . ■ I! 7/i \ / I 11 . I \ 0 O TYP. o e L A - 12 . . TYP. . . . . a . 0 a . o EQ. EQ. r EQ.— EQ. EQ. / Ea. E2. 1 / / IL I P -1 0 8 n I Din 4/ i I - IN \ �1 1 ■ I! \ / I 11 . I \ 0 O TYP. o e A - 12 . . O` r EQ.— W -0" 1 I III // 0 1 IL e IL IL I 0 p i — I - IN \ 1131 ■ I! + I 1-6 A.F.F. � + 0' -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 10" F.F. 4- 0 -0" F.F. + 11' -6" A.F.F. 0 _ + 0' -0" F.F. -0" A.F.F. -0" F.F. � CROWN TYP. SALES AREA ELEVATION I SCALE: 1/4" =1' -0" WALL AT ANGLE A WALL COVERING I P -1 we -1 I PAINT CROWN TYP. EQ. O 3 SALES AREA ELEVATION SCALE: 1/4" = -0' 5 O DIVA BAR ELEVATION SCALE: 1/4" = 1' -0" PAINT WALLS P-2 ES B -3 EQ. 7' -0" O 6 STORAGE ROOM ELEVATION SCALE: 1 /4" TYP. PAINT WALLS S WC -1 n n 0 I P -1 I -e • CO TYP. PAINT CROWN I P -1 TYP. r PAINT WALLS PAINT WALLS P -2 ES 7' -0" n n + 9'--0" A.F.F. -0" F.F. B I B -1 J J P -3 EQ. n EQ. 7' -0" EQ. EQ. O O O z B -1 PAINT WALLS P-2 ES I B -3 PAINT WALLS P -3 PAINT WALLS I P -2 ES PAINT WALLS P -2 ES r I ♦` TYP. + 9"-0" A.F.F. $ +O- O "F.F. N C :a. WALL COVERING WC -3 ♦— C WALL COVERING B A R E E S C E N T U A L S PAINT WALLS P -2 ES I B -3 I I WC -3 FOCAL WALL DETAIL 1 8' -0" N r S I FOCAL WALL DETAIL, SIM, + 9' -0" A.F.F. 0 -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 0' -0" F.F. + 11' -6" A.F.F. + 0' -0" F.F. D ---I P -2 E5 PAINT WALLS I P -2 ES B -1 I SALES AREA ELEVATION SCALE: 1/4" =1' -0° PAINT WALLS .4 4 A -10 PAINT WALLS IP -2ESI TYP. PAINT WALLS P -3 I B1 I O SALES AREA ELEVATION 4 SCALE: 1/4' =1' -0° 4' -0" PAINT CROWN I P -1 TYP. PAINT WALLS P -2 ES PAINT CROWN P -1 TYP. O HIGH -LOW DRINKING FOUNTAIN 40 REFRIGERATOR 33 MICROWAVE GENERAL NOTES 1. REFER TO THE GENERAL NOTES ON SHEET G -1. 2. REFER TO FINISH SCHEDULE ON SHEET A -5 KEY NOTES 0 CONTINUOUS CONCEALED FLUORESCENT TUBE UPLIGHT INSTALLED BY G.C., TYP. 21 RECESSED LOW VOLTAGE DOWNLIGHTS INSTALLED BY FIXTURE MANUFACTURER, TYP. O NEW DOOR AND FRAME. O6 4'X4'X3/4" PLYWOOD TELEPHONE BACKBOARD FRAMED LCD TV WALL SCONCE O ELECTRICAL PANEL 13 53 "x53" HINGED, FRAME MIRROR 20 32 "H x 32 "W x 24 "L BELKIN 220 RACK. 21 SHELVING. 22 EMPLOYEE LOCKERS. O 30 "W x 49 "H x 21"D CLEAR SPACE FOR PRINTER & FILE CABINET 24 BUILT IN MANAGERS DESK - 29" A.F.F., 27" CLEAR FROM BOTTOM OF DESK TO FINISH FLOOR. O PENDANT LIGHT FIXTURES 26 HANDICAP BRAILLE SIGNAGE, SEE A -6 27 HANDICAP UNISEX SIGNAGE, SEE A -6 O 32 "x45" HINGED, FRAME MIRROR COFFERED CEILING, SEE DETAIL 12/A -13 1 City Of TUkw a FEB _. i 2000 Dm-Lke REVIE4lEL FL; CODE COMPLIANCE APPROVED RECEdVED CITY OF T: " JAN 2 2 • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415- 362 -5857 FX: 415- 362 -5044 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 FCC SET Vl 14 W 4t w z- 0 X11 TD Pel w � Lu • U PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: A -7 INTERIOR ELEVATIONS & NOTES • • • associates B ARE E SCENTUALS THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. Co CO p oo Q as 3 c� U) 1- I— Z 0 U 827 Southcenter Ma r EQ.— W -0" 1 I 0 I 1 r j 0 r\ — I IP -1 \ „Z /L OL L . + I 1-6 A.F.F. � + 0' -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 10" F.F. 4- 0 -0" F.F. + 11' -6" A.F.F. 0 _ + 0' -0" F.F. -0" A.F.F. -0" F.F. � CROWN TYP. SALES AREA ELEVATION I SCALE: 1/4" =1' -0" WALL AT ANGLE A WALL COVERING I P -1 we -1 I PAINT CROWN TYP. EQ. O 3 SALES AREA ELEVATION SCALE: 1/4" = -0' 5 O DIVA BAR ELEVATION SCALE: 1/4" = 1' -0" PAINT WALLS P-2 ES B -3 EQ. 7' -0" O 6 STORAGE ROOM ELEVATION SCALE: 1 /4" TYP. PAINT WALLS S WC -1 n n 0 I P -1 I -e • CO TYP. PAINT CROWN I P -1 TYP. r PAINT WALLS PAINT WALLS P -2 ES 7' -0" n n + 9'--0" A.F.F. -0" F.F. B I B -1 J J P -3 EQ. n EQ. 7' -0" EQ. EQ. O O O z B -1 PAINT WALLS P-2 ES I B -3 PAINT WALLS P -3 PAINT WALLS I P -2 ES PAINT WALLS P -2 ES r I ♦` TYP. + 9"-0" A.F.F. $ +O- O "F.F. N C :a. WALL COVERING WC -3 ♦— C WALL COVERING B A R E E S C E N T U A L S PAINT WALLS P -2 ES I B -3 I I WC -3 FOCAL WALL DETAIL 1 8' -0" N r S I FOCAL WALL DETAIL, SIM, + 9' -0" A.F.F. 0 -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 0' -0" F.F. + 11' -6" A.F.F. + 0' -0" F.F. D ---I P -2 E5 PAINT WALLS I P -2 ES B -1 I SALES AREA ELEVATION SCALE: 1/4" =1' -0° PAINT WALLS .4 4 A -10 PAINT WALLS IP -2ESI TYP. PAINT WALLS P -3 I B1 I O SALES AREA ELEVATION 4 SCALE: 1/4' =1' -0° 4' -0" PAINT CROWN I P -1 TYP. PAINT WALLS P -2 ES PAINT CROWN P -1 TYP. O HIGH -LOW DRINKING FOUNTAIN 40 REFRIGERATOR 33 MICROWAVE GENERAL NOTES 1. REFER TO THE GENERAL NOTES ON SHEET G -1. 2. REFER TO FINISH SCHEDULE ON SHEET A -5 KEY NOTES 0 CONTINUOUS CONCEALED FLUORESCENT TUBE UPLIGHT INSTALLED BY G.C., TYP. 21 RECESSED LOW VOLTAGE DOWNLIGHTS INSTALLED BY FIXTURE MANUFACTURER, TYP. O NEW DOOR AND FRAME. O6 4'X4'X3/4" PLYWOOD TELEPHONE BACKBOARD FRAMED LCD TV WALL SCONCE O ELECTRICAL PANEL 13 53 "x53" HINGED, FRAME MIRROR 20 32 "H x 32 "W x 24 "L BELKIN 220 RACK. 21 SHELVING. 22 EMPLOYEE LOCKERS. O 30 "W x 49 "H x 21"D CLEAR SPACE FOR PRINTER & FILE CABINET 24 BUILT IN MANAGERS DESK - 29" A.F.F., 27" CLEAR FROM BOTTOM OF DESK TO FINISH FLOOR. O PENDANT LIGHT FIXTURES 26 HANDICAP BRAILLE SIGNAGE, SEE A -6 27 HANDICAP UNISEX SIGNAGE, SEE A -6 O 32 "x45" HINGED, FRAME MIRROR COFFERED CEILING, SEE DETAIL 12/A -13 1 City Of TUkw a FEB _. i 2000 Dm-Lke REVIE4lEL FL; CODE COMPLIANCE APPROVED RECEdVED CITY OF T: " JAN 2 2 • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415- 362 -5857 FX: 415- 362 -5044 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 FCC SET Vl 14 W 4t w z- 0 X11 TD Pel w � Lu • U PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: A -7 INTERIOR ELEVATIONS & NOTES • • • associates B ARE E SCENTUALS THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. Co CO p oo Q as 3 c� U) 1- I— Z 0 U 827 Southcenter Ma EQ.— r I WC -3 I + I 1-6 A.F.F. � + 0' -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 10" F.F. 4- 0 -0" F.F. + 11' -6" A.F.F. 0 _ + 0' -0" F.F. -0" A.F.F. -0" F.F. � CROWN TYP. SALES AREA ELEVATION I SCALE: 1/4" =1' -0" WALL AT ANGLE A WALL COVERING I P -1 we -1 I PAINT CROWN TYP. EQ. O 3 SALES AREA ELEVATION SCALE: 1/4" = -0' 5 O DIVA BAR ELEVATION SCALE: 1/4" = 1' -0" PAINT WALLS P-2 ES B -3 EQ. 7' -0" O 6 STORAGE ROOM ELEVATION SCALE: 1 /4" TYP. PAINT WALLS S WC -1 n n 0 I P -1 I -e • CO TYP. PAINT CROWN I P -1 TYP. r PAINT WALLS PAINT WALLS P -2 ES 7' -0" n n + 9'--0" A.F.F. -0" F.F. B I B -1 J J P -3 EQ. n EQ. 7' -0" EQ. EQ. O O O z B -1 PAINT WALLS P-2 ES I B -3 PAINT WALLS P -3 PAINT WALLS I P -2 ES PAINT WALLS P -2 ES r I ♦` TYP. + 9"-0" A.F.F. $ +O- O "F.F. N C :a. WALL COVERING WC -3 ♦— C WALL COVERING B A R E E S C E N T U A L S PAINT WALLS P -2 ES I B -3 I I WC -3 FOCAL WALL DETAIL 1 8' -0" N r S I FOCAL WALL DETAIL, SIM, + 9' -0" A.F.F. 0 -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 0' -0" F.F. + 11' -6" A.F.F. + 0' -0" F.F. D ---I P -2 E5 PAINT WALLS I P -2 ES B -1 I SALES AREA ELEVATION SCALE: 1/4" =1' -0° PAINT WALLS .4 4 A -10 PAINT WALLS IP -2ESI TYP. PAINT WALLS P -3 I B1 I O SALES AREA ELEVATION 4 SCALE: 1/4' =1' -0° 4' -0" PAINT CROWN I P -1 TYP. PAINT WALLS P -2 ES PAINT CROWN P -1 TYP. O HIGH -LOW DRINKING FOUNTAIN 40 REFRIGERATOR 33 MICROWAVE GENERAL NOTES 1. REFER TO THE GENERAL NOTES ON SHEET G -1. 2. REFER TO FINISH SCHEDULE ON SHEET A -5 KEY NOTES 0 CONTINUOUS CONCEALED FLUORESCENT TUBE UPLIGHT INSTALLED BY G.C., TYP. 21 RECESSED LOW VOLTAGE DOWNLIGHTS INSTALLED BY FIXTURE MANUFACTURER, TYP. O NEW DOOR AND FRAME. O6 4'X4'X3/4" PLYWOOD TELEPHONE BACKBOARD FRAMED LCD TV WALL SCONCE O ELECTRICAL PANEL 13 53 "x53" HINGED, FRAME MIRROR 20 32 "H x 32 "W x 24 "L BELKIN 220 RACK. 21 SHELVING. 22 EMPLOYEE LOCKERS. O 30 "W x 49 "H x 21"D CLEAR SPACE FOR PRINTER & FILE CABINET 24 BUILT IN MANAGERS DESK - 29" A.F.F., 27" CLEAR FROM BOTTOM OF DESK TO FINISH FLOOR. O PENDANT LIGHT FIXTURES 26 HANDICAP BRAILLE SIGNAGE, SEE A -6 27 HANDICAP UNISEX SIGNAGE, SEE A -6 O 32 "x45" HINGED, FRAME MIRROR COFFERED CEILING, SEE DETAIL 12/A -13 1 City Of TUkw a FEB _. i 2000 Dm-Lke REVIE4lEL FL; CODE COMPLIANCE APPROVED RECEdVED CITY OF T: " JAN 2 2 • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415- 362 -5857 FX: 415- 362 -5044 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 FCC SET Vl 14 W 4t w z- 0 X11 TD Pel w � Lu • U PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: A -7 INTERIOR ELEVATIONS & NOTES • • • associates B ARE E SCENTUALS THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. Co CO p oo Q as 3 c� U) 1- I— Z 0 U 827 Southcenter Ma r I WC -3 I + I 1-6 A.F.F. � + 0' -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 10" F.F. 4- 0 -0" F.F. + 11' -6" A.F.F. 0 _ + 0' -0" F.F. -0" A.F.F. -0" F.F. � CROWN TYP. SALES AREA ELEVATION I SCALE: 1/4" =1' -0" WALL AT ANGLE A WALL COVERING I P -1 we -1 I PAINT CROWN TYP. EQ. O 3 SALES AREA ELEVATION SCALE: 1/4" = -0' 5 O DIVA BAR ELEVATION SCALE: 1/4" = 1' -0" PAINT WALLS P-2 ES B -3 EQ. 7' -0" O 6 STORAGE ROOM ELEVATION SCALE: 1 /4" TYP. PAINT WALLS S WC -1 n n 0 I P -1 I -e • CO TYP. PAINT CROWN I P -1 TYP. r PAINT WALLS PAINT WALLS P -2 ES 7' -0" n n + 9'--0" A.F.F. -0" F.F. B I B -1 J J P -3 EQ. n EQ. 7' -0" EQ. EQ. O O O z B -1 PAINT WALLS P-2 ES I B -3 PAINT WALLS P -3 PAINT WALLS I P -2 ES PAINT WALLS P -2 ES r I ♦` TYP. + 9"-0" A.F.F. $ +O- O "F.F. N C :a. WALL COVERING WC -3 ♦— C WALL COVERING B A R E E S C E N T U A L S PAINT WALLS P -2 ES I B -3 I I WC -3 FOCAL WALL DETAIL 1 8' -0" N r S I FOCAL WALL DETAIL, SIM, + 9' -0" A.F.F. 0 -0" F.F. + 15' -0" F.F. + 11' -6" F.F. + 0' -0" F.F. + 11' -6" A.F.F. + 0' -0" F.F. D ---I P -2 E5 PAINT WALLS I P -2 ES B -1 I SALES AREA ELEVATION SCALE: 1/4" =1' -0° PAINT WALLS .4 4 A -10 PAINT WALLS IP -2ESI TYP. PAINT WALLS P -3 I B1 I O SALES AREA ELEVATION 4 SCALE: 1/4' =1' -0° 4' -0" PAINT CROWN I P -1 TYP. PAINT WALLS P -2 ES PAINT CROWN P -1 TYP. O HIGH -LOW DRINKING FOUNTAIN 40 REFRIGERATOR 33 MICROWAVE GENERAL NOTES 1. REFER TO THE GENERAL NOTES ON SHEET G -1. 2. REFER TO FINISH SCHEDULE ON SHEET A -5 KEY NOTES 0 CONTINUOUS CONCEALED FLUORESCENT TUBE UPLIGHT INSTALLED BY G.C., TYP. 21 RECESSED LOW VOLTAGE DOWNLIGHTS INSTALLED BY FIXTURE MANUFACTURER, TYP. O NEW DOOR AND FRAME. O6 4'X4'X3/4" PLYWOOD TELEPHONE BACKBOARD FRAMED LCD TV WALL SCONCE O ELECTRICAL PANEL 13 53 "x53" HINGED, FRAME MIRROR 20 32 "H x 32 "W x 24 "L BELKIN 220 RACK. 21 SHELVING. 22 EMPLOYEE LOCKERS. O 30 "W x 49 "H x 21"D CLEAR SPACE FOR PRINTER & FILE CABINET 24 BUILT IN MANAGERS DESK - 29" A.F.F., 27" CLEAR FROM BOTTOM OF DESK TO FINISH FLOOR. O PENDANT LIGHT FIXTURES 26 HANDICAP BRAILLE SIGNAGE, SEE A -6 27 HANDICAP UNISEX SIGNAGE, SEE A -6 O 32 "x45" HINGED, FRAME MIRROR COFFERED CEILING, SEE DETAIL 12/A -13 1 City Of TUkw a FEB _. i 2000 Dm-Lke REVIE4lEL FL; CODE COMPLIANCE APPROVED RECEdVED CITY OF T: " JAN 2 2 • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415- 362 -5857 FX: 415- 362 -5044 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 FCC SET Vl 14 W 4t w z- 0 X11 TD Pel w � Lu • U PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: A -7 INTERIOR ELEVATIONS & NOTES • • • associates B ARE E SCENTUALS THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. Co CO p oo Q as 3 c� U) 1- I— Z 0 U 827 Southcenter Ma 15' -0" A.F.F. 3 1 r ..04F-4 14p Ilk \ I - )1 \ • Tit V , L `M associates • ARCHITECTURE • INTERIORS • PLANNING A -9 A -9 A -9 2747 SAN FRANCISCO, A 94110 PH: 415 - 362 -5857 FX: 415-362-5044 D A R E E S C E N T U A L S 22ND FLOOR STEVENSON STREET SAN FRANCISCO, CA 94105 (415) 489 -5478 B.0, BULKHEAD 3/4" REVEAL 13' -0" A.F.F. oith Ea 1 ( i h a . NOTES: ALL STOREFRONT DESIGN MUS BE INDEPENDANTLY SUPPORTED FROM THE MALL STRUCTURE. LANDLORD'S MALL BULKHEAD CAN ONLY BE USED FOR LATERAL SUPPORT. GRAPHICS APPLIED DIRECTLY TO THE STOREFRONT GLASS MUST HAVE MATCHING LETTERS AND FEATURES ON BOTH SIDES OF GLASS TO CREATE A FINISHED LOOK WHEN VIEWED FROM EITHER SIDE. MAXIMUM LETTER HEIGHT OF LETTERS IS 3 ". L L T.O. SIGNBAND w .� ESCENTU — A.. L S ■ AR 11'- 0"A.F.F. EXISTING SECOND LEVEL SPANDREL THESE PLANS AND SPEOFICAT1ONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. TA. GLAZING /ENTRY BRUSHED STAINLESS 8 8 8 e 3/4 "x3/4" CLER ANOD ALUM REVEAL EXISTING REV DATE DESCRIPTION SET ' 10/12/07 DD S 12/07/07 CD SET ' NOTE :SIGNAATTACHMEN MFR. PROP DRAWINGS FOR R� STEEL LETTERS WITH LED BACKLIT. PAINTED MDO FASCIA P -1 3/4" REVEAL :::;;;:: TENANT LEASELINE PR. 3'x8' WOOD � j % J11 "' NEUTRAL PIER EXISTING � II I 1 172 W T - AI NT B L ACK. G.C. TO PAIL LETTERS 7 F 1 5TEREG' . i 7. Z8 r ,} 4{TECT E E OF ; A5' NGTON - COLUMN ENCURESEE TENANT LEASELINE _ • - - , WHITE LEXAN BACK —UP W FRENCH DOORS 0' -0" A.F.F. 0 II IF N OTE •SIGNAGE FABRICATOR TO SUBMIT SHOP DRAWINGS FOR REVIEW • %!% T % =t -.. . . . ... O i \ - •• SIGNAGE ON SEPARATE CIRCUIT AND ON 7 DAY TIME CLOCK SET TO MALL'S OPERATING HOURS. LOCATE DISCONNECT SWITCH OR TRANSFORMER WHERE ACCESSIBLE FOR SERVICING YET NOT VISIBLE TO PUBLIC. - - -- .. CI STOREFRONT \NE v--_, Q CODE CI-OMPLIA APPROVE FEB - - O ; Id Soutl enter Park' A 98188 -c :ing Count 12" MARBLE TILE BASE 12" MARBLE TILE BASE ELEVATION SIGNAGE SECTION B 1 1/2" THICK P1 BRUSHED SCALE : 1/2" = f -O" z I ' 4 .�. l"'�3IIIJ STAINLESS STEEL LETTERS W /LED BACKLIT 1) ...010.1(0 0 PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: d • : ,. A R E SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: STOREFRONT ELEVATION AND DETAILS RECEIVED CITY OF TUKWILA DEC 19 2007 PEHMIT CENTER A_8 SIGNAGE ELEVATION A 11' -6" A.F.F. B.O. CEILING Adik 8' -0" A.F.F. T.O. WOOD DOORS O' -0" A.F.F. T.Q. FIN. FLR. MARBLE TILE BASE SCALE: 1/2" = 1' -0" i SECTION @ ENTRANCE / EXISTING BULKHEAD (VERIFY LOCATION IN FIELD). PROVIDE 5/8" TYPE "X" GYP. BD. ON TENANT SIDE OF BULKHEAD. PAINTED 3/4" FIRE RETARDANT MOF OVER 5/8" F.T. PLYWOOD OVER 4 ", 16 GA. STUDS 15' -0" A.F.F. AL B.O. BULKHEAD 13' -0" A.F.F. T.O. SIGN BAND SIGNAGE UNDER SEPARATE PERMIT 11' -0" A.F.F. AL I T.O. ENTRY ALCOVE / B.O. SIGN BAND (N) FIXED TRANSOM WINDOWS W/ DIVIDEERS AND DUAL TEMPERED GLASS PAINTED TRIM (F.T.); FIXED WINDOW ON OPPOSITE HAND LEASE LINE E X T E R I O R • ► I .� � ►1 11 - 6 " A.F.F. ��I B.O. CEILING � _' \ I � A.F.F. B.O. PERIMETE SOFFIT I N T E R I O R SCALE: 1/2" = 1' -0" N I SECTION @ PILASTER EXISTING BULKHEAD (VERIFY LOCATION IN FIELD). 15' -0" A.F.F. a di 15' -0" A.F.F. B.O. BULKHEAD B.O. SOFFIT 13' -0" A.F.F. ALI T.O. SIGN BAND 11' -0" A.F.F. I T.Q. ENTRY ALCOVE / I B.O. SIGN BAND E X T E R I O R 1 k A - zz z PROVIDE 5/8" TYPE "X" GYP. BD. ON TENANT SIDE OF BULKHEAD. PAINTED 3/4" FIRE RETARDANT MOP OVER 5/8" F.T. PLYWOOD OVER 2 LAYERS OF 1/2" F.T. PLYWOOD OVER 4 ", 16 GA. STUDS 11' -6" A.F.F. B.O. CEILING 10' -6" A.F.F. B.O. PERIMETER SOFFIT SCALE: 1/2" =1 I N T E R I O R SECTION @ GLAZING \ i ._.I 144,0 1 A -10 EXISTING BULKHEAD (VERIFY LOCATION IN FIELD). PROVIDE 5/8" TYPE "X" GYP. BD. ON TENANT SIDE OF BULKHEAD. PAINTED 3/4" FIRE RETARDANT MDF OVER 5/8" F.T. PLYWOOD OVER 4 ", 16 GA. STUDS 15' -0" A.F.F. ki B.O. BULKHEAD 13' -0" A.F.F. AL T.O. SIGN BAND SIGNAGE UNDER SEPARATE PERMIT 11' -0" A.F.F. T.O. WINDOWS E X T E R I O R (N) FIXED CASEMENT WINDOWS W/ DUAL TEMPERED GLASS City Of Tuk NOTES: TENANT IS TO SUPPLY 5/8" TYPE "X" GYP. BD. ON TENANT'S SIDE OF LANDLORD BULKHEAD AT STOREFRONT AND PROVIDE RATING AS REQUIRED BY CODE. REVIEWED FOR CODE COMPLIANCE APPR FEB 1 2008 RECEIVED CITY OF TUKWILA DEC 19 2007 PENIVMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 13th STREET SAN FRANCISCO, CA 94110 PH: 415 -362 -5857 FX: 415- 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECRCATIONS. AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE TIE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET a 4t H crl z U 4t aG co CO PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: STOREFRONT SECTIONS A -9 1/2 CLEAR TEMPERED � ' :::. i II ::: � 2 ilk GLASS WITH POLISHED EDGES J. I L � _:': ___.01 R-19 BATT LEASE LINE I I `� ,.. 1,..,,, : • : :: :: ::•:: :: ::: ., : ;. -"•" i l : : : : : :: ' ' • i,.. :. END PILASTER BEYOND , � o p . ■ ■ coo - - y k � / /J� /�� % /1rl �i\ � �I�� . f , � .I�..��III�� �i �% ,,ter � ■ associates • ARCHITECTURE INTERIORS • • PLANNING INSULATION P�� i , 1/8" 1/8" 1 / 8 " OPENING DIMENSION GLASS EDGE 1 GLASS EDGE @ WALL @ MID - WINDOW 6 GALV 18 GA METAL JOISTS [la 16 „ O.C. ENTRY CORRIDOR BLACK METAL EDGE BEAD 2' WIDE CONT ALUM VENT PAINTED 1 x (F.T.), — PRIME ALL SURFACES 41011141 !��. I: i ! :.:A l SIGN BAND NOTES. 1. PROVIDE GLASS CLIPS AS REQ'D. SEE STOREFRONT ELEVATION SHT A -8. 2. USE LIGHT GREY SILICONE A T GLAZING CORNERS, TIP. 2 " I 2” PAINT BLACK. . _ 111Will--: ;"%':14 END PILASTER BEYOND 274719th STREET SAN FRANCISCO, CA 94110 PH: 415- 362 -5857 F7C :415 - 362 -5044 BARE E S C E N T U A L S 71 STEVENSON SO STREET S 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 TRANSOM WINDOWS Nw LEASE LINE HEAD \ \ \ \ -• y ~ . \, FILLER AS 1 \ � r , / SIGN BAND DETAIL n r n ' ri HEAD GLAZING SCALE: NTS � SCALE: 3" = ^ 11-0" 9 3" = 1 SCALE: 3 SCALE: 3" = V-0" THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME ARO LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /DR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT I5 STRICTLY PROHIBITED. 5/8 G.W.B. 41 � :::. ... ••: - -- �� 2 S EALANT + T) �C R ®�69��.�► AIP OW 0 ° Tu 5�� AI � � j I! I , ;: - l ; -- 1 I � REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET Nr113 IRE ' - FREE` �'._. AR., E AZ = , ; +ATE F WASH! ". T � �� ,- r /1��/� •. CONCEALED CLOSER BEYOND 1_': � ,� +` � � - �� � BACKER ROD PAINTED 1 x F.T. PRIMED ALL SID FILLERS (FIRE TREATED) PRIMED ALL SIDES :-:•:- - Mil � PAINTED 1x BAND PRIMED S �r AI •:-:-:• I I -- = _r; A � . .... • • 2 BEYOND I '� ... -:� : \ \' \ \ PAINTED ALL SIDES I PAINTED 3/4" FIRE RETARDANT MDF OVER 5/8" F.T. PLYWOOD OVER I STUDS TENANT LEASE LINE TRIM PAINTED �I � PAINTED FILLER PAI �, i/' ` •• I � • ■! 1 \ FILLER AS i- :: - Id Southcenter enter Parkway A 98188 -2888 :ing County SHIN \ PAINTED, R -13 BATT LION :: b� PRMED ALL SIDES 1/4" DOOR WITH DUAL 1/4 " tit LEASELINE 2 TEMPERED GLAZING L S PAINTED ALL SIDES. I I SEALANT +BACKING' ROD CUSTOM SIZED PAINTED WOOD TRANSOME WINDOW, PRIMED ALL SURFACES rpm– JAMB BEYON D END PILASTER DETAIL DOOR HEA ... DISPLAY WINDOW HEAD SCALE: 1 -1/2' = V-0" SCALE: 3" = 1' -0" 8 SCALE: 3 = 1 -0" 2 " TENANT LEASE LINE PAINTED 3/4" FIRE RETARDANT MDF OVER 5/8" F.T. PLYWOOD OVER 2 LAYERS OF 1/2" F.T. PLYWOOD OVER 4 ", 16 GA. STUDS PAINTED TRIM (F.T.),PRIME ALL SURFACES 1/2' STEEL REVEAL, PAINTED BLACK DUAL SEAL SET DUAL GLAZED JAMB 2,� � DUAL GLAZING TEMPERED GLASS WITH 1/4 TEMPERED GLASS r �' 3 " 2 2 / LEASE LINE PAINTED CUSTOM SIZE FIXED UNIT WINDOWS THINSET MARBLE TILE BEYOND BEYOND 5/8" G.W.B PAINTED R BATT SHIM it CUT BACKNOSE OF WINDOW / � � � 4 SILL THINSET MARBLE BASE OVER 1/2 PLYWOOD BACKING (USE EXT. PLYWOOD ON EXTERIOR APPLICATIONS). 4” GALV.16 GA STUDS 2 1/4" THICK WOOD DOOR BRONZE KICK P LATE IIIL I I1 END PILASTER BEYOND PAINTED WOOD PIER W/ PROJ. NO.: 7.112 PM: A.M. JC. A.C. CHECKED: SEALANT + BACKER ROD FILLER " , �; ���� � �� LIi 1 v ��. �__ ,��r -13 INSULATION THINSET MARBLE BASE, POLISHED ALL VISIBLE EDGES WOOD BASE R -13 BATT INSULATION T.O. FIN. FLR. ... - �„ �'` (BRUSH FINISH ) BOTH SIDES SET THRESHOLD IN oir �' TRIM IN FRAME SURFACE SCALE: ( DO NOT SCALE DRAWINGS) APPLIED. 1/2 „ PAINTED BLACK . GYP. BD WOOD BASE :: � . � i ; i . � '! ! � :' z . ' � REVEAL. THINSET MARBLE TILE. SHEET TITLE: STOREFRONT SECTIONS R BATT �`:• :: @12" O.0 DUAL SEAL, SET SEALANT -13 INSULATION T.O. FIN. FLR. `�' ALIGN 1ST JOINT W/ PIER ABOVE. INTERIOR AND EXTERIOR FINISH SHOULD BE FLUSHED TO EACH OTHER L !; ! ' ; _ ,`, PLYWOOD ON SEALANT BEAD, COVER W/ BACKING ROD AND SEALANT TO MATCH SIDEWALK PLYWOOD ON SEALANT BEAD COVER ER W/ BACKING ROD AND SEALNT COLOR TO M ATCH MALL TILE. WALL MOUNTED ELECTRO MAGNETIC N TIC HOLD OPEN WOOD FINISH FLOOR � MALL TILE A_ 1 0 r RECEIVED CITY OF TUKWILJ i END PILASTER AT FLOOR 10 ENTRY DOOR THRESHOLD ENTRY CORRIDOR AT FLOOR DISPLAY WINDOW SILL DEC 19 2007 PERMIT CENTER SCALE: 1 -1/2" = 1' -0" SCALE: 3" = V -0" 4 SCALE: 3" = 1' -0" 3" = V -0" v a d a 4 PAINTABLE FIRESTOP SEALANT (BOTH SIDES) UNDERSIDE OF DECK ABOVE S /8' DEFLECTION GAP 64 SLOTTED TRACK (SLP —TRK OR Ea) 5/8" GYPSUM BOARD CEILING FINISH PER SCHEDULE 5/8" GYPSUM BOARD TYPE "X" (60TH sums) ILL NO U465 I THE FOLLOIOCG FASTENING =lliE71ENTS ARE TAKEN FROM ILS WPEORCADCIL FOR THE WOWED ASSEMBLY. REFER TO 0.S OOCIA ENTAIION FOR COI7PEE1E ASSAIBLT REgpROFEWIS AHD ALLOWABLE MICAS MOW BOMO: 5/Y 1150C, 4 FT INIe, ATTAQ ED TO STEEL STUDS AND FLOOR ANO CEII.NG TRACK VIM 1 IN. LONG, T1PE S STEEL SCREIS SPACED 8 8L CC. ALONG EDGES OF BOARD MO 12 IN. OC IN THE FIELD OF DE DOMO. JCBITS ORIENTED VERTICALY NID STAGGERED ON CFPOSTE WE5 OF THE A.Y. STEI1 1ILE WAINSCOT, THIN —SET (WERE OCCURS) 6" STEEL STUDS ® 16" O.C. WALL FINISH PER SCHEDULE 6" CONTINUOUS UNPUNCHED STEEL TRACK FLOOR FINISH WHERE OCCURS SEALED CONCRETE SLAB, SEE STRUCTURAL DRAWINGS PAINTABLE huttSiOP SEALANT (BOTH SIDES) RAMSET AS REQUIRED WHERE WALL ABUTTS A TENANT SPACE, GYPSUM BOARD LAYERS SHALL BE SUPPLIED AND INSTALLED BY TENANT 1 HOUR PARTITION AT FINISHED CORRIDOR ,=0. a a v a UI- NC U465 I THE FOU.OVANG FASTENING REQUIREMENTS ARE TAKEN FROM UL'S SPECIFICATION FOR THE INDICATED ASSEMBLY. REFER TO UL'S DOCUMENTATION FOR COMPLETE ASSEMBLY REQUltEMENTS AND ALLOWABLE OPTIONS: GYPSUM BOARD: 5/8' THICK, 4 FT WIDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEIUNG TRACK WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 8 IN. DC. ALONG EDGES OF BOARD AND 12 IN. OC IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. a A PAINTABLE FIRESTOP SEALANT (BOTH SIDES) UNDERSIDE OF DECK ABOVE 5/8" DEFLECTION GAP 6" SLOTTED TRACK (SLP -IRK OR EQ) FINISH PER SCHEDULE NOTE FIRE RATNG CF WALL ASSEMBLY IS NOT REQUIRED TO EOM) ABOvE TENANT WING. GYPSUM BOARD TO RE NEW MIN. r CLEAR BELOW RR DE OF DELI( ABOVE TO ACCMICO 1E T9MANT MAC REIURN NR 5Y5TEA1. CEIUNG BY TENANT (WHERE OCCURS) 6' STEEL STUDS 0 16 O.C. 5/8 GYPSUM BOARD TYPE "X' (BOTH SIDES) RAMSET AS REQUIRED 6" CONTINUOUS UNPUNCIED STEEL TRACK FLOOR FINISH . CONCRETE SLAB, SEE STRUCTURAL DRAWINGS PAINTABLE FIRESTOP SEALANT (80TH SIDES) ME; ALL GYPSUM BOARD LAYERS SHALL BE SUPPLIED AND INSTALLED BY TENANT 1 HR TENANT DEMISING PART1ON (TYPICAL? ,. rnIC LOW VOLTAGE 5/8" GYP. BD. 17' -6 3/4" • B.O. (E) STRUCTURE, V.I.F. MTL. STUD FRAMING, TYP. FLUORESCENT CONTRAST MR NOTE: PER TENANT CRITERIA GYP. BD. AT SALES /STACK WALL TO BE FROM FINISH FLOOR TO B.O, STRUCTURE PROVIDE BACKING AT ALL WALL MOUNTED ITEMS SEE WALL LEGEND — SHEET AO.0 FOR SIZE, GAUGE & SPACING K, TO ND BOTTOM; ANCHOR TO ADJACENT ATRUCTURE/SLAB AT 24" O.C. MAX AND 12" FROM EACH END. D EFLECTION HEAD HERE OCCURS (W ) i ' r - a I �.imill `I �� / � ■ ° ° ° ° ° ° ° NOTE: COUNTER SINK NAILS; PUTTY AND SAND BEFORE PR IME /PAINT. y. 1 -1/2" X 3" X 16" GA. CHANNEL CLIP ANGLE 1/4 LESS THAN 1/4" STUD WIDTH, TYP. - ATTACH AT EVERY ATUD WITH (4) 5/8" O #5 -12 SCREWS OR 3/4" WELDS IN (3) PLACES 10 � NEW WALL UNIT REFER TO MILLWC / 11‘,_ PAINTED SUPERIOR MOULDING HB35 FINISHED CEILING SOUND ATTENUATING BAIT INSULATION, WHEN OCCURS � • 5 OPEN HOLES B. O. CEILING LINE RATED GYP. BD, S YSTEM, e e ° ° ° ° o e e �� �, 1 . , / r�� e `` associates • ARCHITECTURE • INTERIORS • PLANNING -60 WALL SEE DETAIL 5 /AO-4 FOR SPECIFIC METAL STUD TRACK ANCHORED TO FLOOR �� � MDF BASE DIRECT 4 � WALL REQUIREMENTS ' AT 24" O. C, MAX AND 9 OPEN HOLES WALL BASE. TYP. SEE. FINISH SCHEDULE 1 , 12" FROM EACH END. LARR# FOR DRIVE PIN I = 2582 ° ° ° ° ° ° a e ° a CONT, S EALANT, TOP AND BOTTOM OF PARTITION, BOTH SIDES +s-s _ 3/4" 16 GA. COLD— ROLLED CHANNEL - LOCATE AT 4' -0" O.C. HORIZONTALLY, OR AS REQUIRED BY LOCAL CODE GLU -DOWN WOOD FLOORING FINISH FLOOR V Y j 9 OPEN HOLES 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415-362-5857 FX 415- 362 -5044 BARE E S C E N T U A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 ° ° e o e ��1�'����' a e e ° A STORES IN SEISMIC ZONES 3 & 4 ONLY; PRO VIDE CUP ANGLE(S) + 5' -0" A.F.F. AT WALLS 1 0'-0" HIGH OR LESS, AND EVERY 4' -0" AT WALLS GREATER THAN 10' -0" OR AS REQUIRED BY LOCAL CODES \ \ \\ (E SUBFLOOR 1 . A CONNECTIONS TO STRUCTURE ABOVE TO BE ATTACHED TO TOP CHORD OF STEEL TRUSS OR TO A HORIZONTAL MOUNTING PLATE RUNNING BETWEEN THE TOP CHORD OF STEEL TRUSSES. 2. 1 —HR RATED WALL ASSEMBLY SHALL COMPLY WITH ASSOC. #WP- 1200 /ICBO #1632 ` `\ `\ `\ `\ `\ `\ `\ ,..\ `\ `\ ' 10 OPEN HOLES 1 HOUR RATED WALL _ WALL BASE ___ 9 j 1 i ONE HOUR RATED PARTITION BRIDGING DETAIL 5 OPEN HOLES SCALE: 3" = 1-O" \____} SCALE: NTS e SCALE; NTS THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODU CTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. `-" 1 X 4 WOOD TRIM WITH ' 17' -6 3/4" /. �1 (E) STRUCTURE ABOVE, j 1/4" X1/4" ACCENT TRIM DOOR - SEE PLAN FOR SWING STOCKROOM REV DATE DESCRIPTION 1 0/12/07 DD SET 12/0 07 CD SET STRUCTURE ik B.O. E (E) STRUCTURE, V.I.F \ ° v � (E) ABOVE (16' -0" HIGH 20 GA METAL TRACK SEE 1 �� OR GREATER) V E Cf��pa METAL STUD I \,...:78 ! ;. .. R d STS .13 r 1. ;,,p E� W I{INON \ • •-• , , 3 -5/8" DIAGONAL BRACING, .................. 48" O.C. MAX. AS REQ'D _— - • DIAGONALLY BRACED AT 24" O.C. 3" X 3" X 1' L 20 GA. SECTION AT WALL UNIT ALL U �' � . %' 6" ABOVE CEILING LINE (� T.O. GYP. BD. SCALE: 1 1/2" = 1' -0" SALES AREA FIN. CEILING WHERE OCCURS -0" METAL CLIP ANGLE u L W/Si 4' - 0" MAX 12' - O" 12' - O" 12' - O" 12' - 0" 4' - 0" T.S. N.T.S. N.T,S. N.T.S. N.T.S. MAX .T.S, VARIES B.O. CEILING LINE `! NOTE: PROVIDE BACKING AT ALL WALL MOUNTED ITEMS ATTACHMENT SCHEDULE COMPRESSION STRUT 1 1 1 1 1/2" X 13/8" DOOR STOP NON -RATED GYP. BD. WALL SYSTEM. SEE Q FOR SPECIFIED WALL 1X FZNGER- JOINTED WOOD JAMB MATERIAL OF BUILDING 2 FASTENERS ,, Al SOUND ATTENUATING o cV ~ r Z 1" X 4" WOOD TRIM WOOD REQUIREMENTS. SEE CONCRETE SLAB IF BATT INSULATION, MAIN RUNNER ) FIELD SUSPENSION POINT FOR ATTACHMENT TO EXISTING WALL .�, WHERE FURRED. WHEN OCCURS. BRIDGING SYSTEM SEE g _ �I ' ANCHORED TO FLOOR AT 24" O.C. MAX AND 12" FROM EACH END. LARR# FOR DRIVE PIN = 2582 METAL DECK W/ CONCRETE 1 -3 ANCHORS BLOCKING AND SHIM o z 5/8" TYPE ' X' GYP BD. ON 3 5/8 METAL STUDS AT 16" O.C. -- -_ WALL BASE, TYP. +0' - 0" A.F.F. SoutP Ater Park 98188 -2 lg Count METAL DECK W/ LIGHTWEIGHT FILL (ZONOLITE, GYPSUM) 2 SUB-DRILLED RCP CEILING d- FINISH FLOOR / STRUCTURE � F-. s . _ . WOOD JAMB DETAIL NONRATED PARTITION ATTACHMENT AT STRUCTURE HANGER WIRE , SCALE: 3" = 1' -0" SCALE: NTS SCALE: NTS SUSPENDED CEILING A CEILING I- ASSEMBLY CLIP ANGLE AT WALL -._ -- ---- -___ -. - (E) WALL DIAGONALLY 7 END F INISH FLOOR -� FLATTEN (TYP) ATTACH TO OF STRUT RUNNER WITH #10 X 1 1/2" SHEET MTL SCREWS ELEVATION = z METAL STUD BRACED AT 24" O.C. TO STRUCTURE ABOVE VERTICAL ANTI UPLIFT , - STRUT OR 1/2" DIA. RIGID CONDUIT AT 144 SQUARE FEET OR LESS. NOTCH LOWER END TO FIT OVER RUNNER WITH 1/4" DIAMETER MACHINE BOLT ` ' STRUT SIZING CHART CONT. 2" X 2" 20 GA. METAL CLIP ANGLE ATTACH AT EACH STUD 111 111111.v--- / SIZE MAX HT NOTES : WOOD 0.5" DIA X 22 GA 3' -0" 1. INSTALL CLG GRID USING #12GA WIRE HANGERS @ 4 FT MIN O.C. & 12' -0" MAX FROM PERIMETER WALL. 2. CALIFORNIA BUILDING CODE, CONTINUOUS ONE LEVEL. PER SECTION 25,2A0 SINGLE LEVEL DRYWALL CEILINGS ARE EXEMPT FROM LATERAL FORCE BRACING REQUIREMENTS WHEN WALL ARE NOT OVER 50 FEET APART. WHEN WALLS ARE OVER 50 FEET APART, THE CEILING SHOULD BE EXAMINED FROM BRACING REQUIREMENTS. 3. IBC - SEISMIC ZONE D /E /F SINGLE LAYER DRYWALL CEILINGS ARE EXEMPT FROM LATERAL FORCE BRACING REQUIREMENTS, REGARDLESS OF ROOM SIZE. METAL TRACK (20 GA. MIN) METAL PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: 0/5" DIA X 22 GA 4' - 3" AND 3/8" DIAMETER WEJ -IT EYEBOLTS TOSTRUCTURE , 5/8" GYP. BD. OVER FURRING STUDS BLOCKING AS 1 �� DIA X 20 GA 5' ABOVE �� �` �> •, / REQUIRED ATTACHMENT SCHEDULE SCALE: (DO NOT SCALE DRAWINGS) �, 1.25 DIA X 20 GA 7' 5/8 GYP. BD 12 GA LATERAL CONSTRU OF (E) FULL- HEIGHT WALL FASTENERS AT CONT. ANGLE FASTENERS AT BRACING `..� 5/8" GYP. BD. SUPERIOR MOULDING HCR 31 -62 MDF BRICK 1 -3/4" X 3/16" DIA, TAFOON ANCHORS AT 24" O.C. TO ALIGN W /STUDS BRACING NOT REQUIRED 1.5" DIA X 20 GA 8' - 6" SHEET TITLE: DETAILS (4) BRACE WIRES AT 12' - 0" Q.C. ' �� 2 �� DIA X 20 GA 11'-6" EACH WAY, SPLAY AT 45 DEGREES FROM EACH OTHER AND SET BACK 1" � FROM INTERSECTION OF ' � CMU SAME BRACING NOT REQUIRED - ._�� �- CONCRETE SAME BRACING G NOT REQUIRED DIA X 18 GA 14' -6" 3 MTL STUD W /GYP. BD. # 12 - 14 X 1 TO EACH STUD 3" X 3 " X 20 GA. CLIP ANGLE X O' 3" DIA X 18 GA 17' - 3" RUNNERS. SPACING AS 6" MTL STUD W /GYP. BD. SAME 2 #8 -18 X 1/2" HWH TEKS/RECEIvPD CROSS REQUIRED BY CODE. MAIN RUNNER RUNNER NOTE: PROVIDE WALL TRACK AT VERTICAL SURFACES CROWN WOOD #1 X 2' - 2 "L RO EACH WALL STUD IN SUB - DRILLED HOLES BRACE ANOYFTWEIYKWILk WE, S; 1 a ?M7 3.5" DIA X 16 GA 23' -3" A_ 1 2 MOULDING GYP. BD. CLG. SUSPENSION SYSTEM O GYP. BD. CEILING(SEISMIC) CROWN MOULDING ATTACHMENT AT FURRED WALL SCALE: NTS SCALE; 3" = 1'-0" 4 SCALE; 6" = 1' -0" 0 SCALE; NTS D 1)74-fil BALMER 8' -0° GWB CEILING - SEE A -4 ■ NOTES:: 1) GRID AND PANEL DIMENSIONS ARE SHOWN FOR DESIGN INTENT ONLY. 2) G.C. AND MANUFACTURER ARE C. RESPONSIBLE FOR VERIFYING FIELD DIMENSIONS AND METHOD AND SEQUENCE OF INSTALLATION. 3) DIMENSIONS TAKEN FROM CENTER LINE OF GRID CROWD MOLDING ARMSTRONG PRELUDE PAINTED SYSTEM / 4° I 1 ` _ "i N - \ . „.......40 � 1/2" REVEAL 3-1/2" CLEAR ACRYLIC LETTERS W/ c' / E EQ. Q MIRROR BACK `' B b 4----- 14 4 f 3 FORM ALABASTER PANELS w E r ESCENTUALS 1 I - m N U , A 4 L ; iiv � F �y� O II a ■ associates • ARCHITECTURE • INTERIORS PLANNING LIGHT POCKET - - `�`� , - d\ A. GRID/ PANEL PLAN 8 , ° 8'- 11/2" A -13 I L -13 BALMER T202 CR OWN ROWN MOLDING I I u II II 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415- 362 -5857 BARE E S C E N T U A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489-5478 K 4" TYP. u , I 1' -0" +/— 6' -0 1/4" 1' -0 II FG FIXTURES, IXTURE (LIGHTS OVERLAP 4" AT END, TYP.) II Alb O' -6" A.F.F u II 1 7 T.O. BASE II BRUSH WALL ELEVATION U II . \ SCALE: 1/2" = 1' -0" \ B. LIGHT FIXTURE LAYOUT PLAN THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF AAR /ESCENTUALS. M IA LS , DISCLOSURE Ate /OR USE OF THESE E MATERIALS (OR IOR ANY Y POR PORTION ION OF OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. LAYLIGHT PLAN 3 5/8" METAL STUDS WITH THREE S.M.S AT EACH END 3 5/8" X STUDS X 16 GA DS DECORATIVE WOOD FRAME SCALE: 1/2" = 1'-O" (BY OWNER) WOOD C) REV DATE DESCRIPTION 10/12(47 DO SET 12/07/07 CD SET I 0.- 718 RE el TEM 1 _ ! .) A. ' Ate MO ' 2 ' 1,411 , • E OF WAS °ING '+ ...-------w 3 -5/8" METAL STUD (a 4' -0" 0.C. BRACE @ 45° T O STRUCTURE + + + + WITH 1/4" OVERLAP OVER SCREEN r S +'> 8" 8" MAX. [nl PERIMETER / y a = "I #10 EACH 1 1 - ' ..2. '; IT 01111 b 4 12 GA. VERTICAL SUPPORT WIRE @ 4' -O" O.C. WIRE MUST NOT EXCEED A 1/6 SLOPE ( ±10 °) Q ` 16 GA i ' MIN. OF 3 TIGHT TURNS BRACKET EXPOSED FRAMIN,G1ff&FOR__ irralHraw I !Illi!II muniNII r � COD: + N 3 FORM ALABASTER WHITE WITH GREY 16" O.0 > '\ �- /2" "X" HEAVY DUTY SUSPENDED CLG. 5/8" TYPE GYP. BD. CLG. GRID MEMBER OVER MTL. STUD BALMER T202 -PL CROWN FRAMING MOLDING 4" ON FACE City of 7- Likw LAYLIGHT DETAIL SECTION AT TV OPENING SCALE: 1 -1/2" = 1' -0" figo SCALE: 1- 1/2 " =1' -0" 2' -10 PROVIDE 1/4" OVERLAP 2' -3° I OF FRAME OVER SCREEN, TYP. AT ALL SIDES F LIIk I VISPLAY INVISIBLE PANEL irif■rif I ;i i EDGE OF TV SCREEN l BEYOND (SHOWN DASHED) u_ Q = ,, 5'6" A .F.F. w • I w r I r � PROJ. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: VISPLAY GLASS PANEL I I; ; - FIN. FLR. Li, o d Ell ) ! l n t SCALE: (DO NOT SCALE DRAWINGS) - I A FLUOR. LIGHT SEE ELECTRICAL DWGS. 5 3/4" SHEET TITLE: DETAILS y 1/4" WHITE PLEXIGLASS DIFFUSER 1/2" WHITE U ,, ^ DUPLEX OUTLET FOR TV, CHANNEL LOCATE AT REAR OF RECESS RECEIVED WOOD INNER FRAME BY GC, PAINT CITY OF TUKW:LA \ FLAT BLACK DEC 1 9 2007 LINE OF GYP. BD. C -3 RECESS BEYOND (SHOWN DASHED) PERMIT GLN TE i 5/8" GYP BD OVER 1 -1/2" - MTh. STUDS. DECORATIVE WOOD FRAME (BY OWNER) BRUSH WALL DETAIL FRAME AT FLAT SCREEN TV 4 SCALE: 3" = 1' -O" 0 SCALE: 1.1/2 " -1' -0" • - -• ELECTRICAL SYVBOLS SYMBOL DESCRIPTION A a 0 3 LIGHT OUTLET a- SWITCH DESIGNATION 3 -CIRC. NO. (SEE PANEL) A- FIXTURE TYPE (SEE SCHEDULE) rid CONDUIT RUN CONCEALED IN WALL OR CEILING. CROSS LINES INDICATE NO. OF #12 COPPER WIRES EXCLUDING GND CONDUCTORS WHERE REQUIRED. (INSULATION TYPE THHN /THWN U.O.N) / � CONDUIT RUN WITH GROUND CONDUCTOR -- CONDUIT RUN W /ISOLATED GROUND CONDUCTOR - - - -- CONDUIT RUN IN FLOOR OR U.G. -X- CONDUIT RUN, EXPOSED REV DATE I CONDUIT STUB UP _____,D -. CONDUIT STUB DOWN -5-- SOUND SYSTEM CONDUIT -T- TELEPHONE CONDUIT ONLY I Souti ter Park 98188 -c ig County CONDUIT SEAL - - --HI" GROUND CONNECTION ] CONDUIT STUB OUT WITH CAP PROJ. NO.: 7112 PM: A.M. JC: A.C. CHECKED: -CL- FLEXIBLE CONDUIT SHEET TITLE: SYMBOLS AND NOTES PANEL MOUNTED CIRCUIT BREAKER ---0 o--- --0I- PANEL MOUNTED FUSED SWITCH S SINGLE POLE SWITCH S2 TWO POLE SWITCH S 3 THREE WAY SWITCH SR MOMENTARY CONTACT SWITCH SM MOTOR RATED SWITCH J DISCONNECT SWITCH, FUSED n--I DISCONNECT SWITCH, NON FUSED I-[ DIMMER SWITCH HD PUSH BUTTON 1,/ MAGNETIC MOTOR STARTER MU PANELBOARD SWITCHBOARD -1 L: TERMINAL CABINET TELEPHONE BACKBOARD I SURFACE RACEWAY T TRANSFORMER 0- MOTOR CONNECTION & 120V, 20A DUPLEX RECEPT. @ +15" UON CDP 120V, 20A DUPLEX RECEPTACLE & DOUBLE DUPLEX RECEPTACLE ® FLOOR MOUNTED RECEPTACLE RECEPTACLE WITH G.F.I. (1.0.) ISOLATED GROUND RECEPTACLE HALF SWITCHED RECEPTACLE 208/240V RECEPTACLE ® OR - SPECIAL RECEPTACLE e- LOCK ON DEVICE JO JUNCTION BOX ® FLOOR MOUNTED J -BOX 14 TELEPHONE OUTLET ® TELEPHONE FLOOR OUTLET II TELEPHONE /DATA OUTLET KI DATA OUTLET II INTERCOM OUTLET K9 CLOCK OUTLET QT THERMOSTAT OUTLET CABLE TV. OUTLET ifi i OR 6 ILLUMINATED EXIT SIGN (WALL OR CLG.) e SMOKE DETECTOR 05 MOTION SENSOR (WALL OR CLG.) Q SYSTEM SMOKE DETECTOR ABBREVIATIONS SYMBOL DESCRIPTION A/C AIR CONDITIONING CO CONDUIT ONLY CKT CIRCUIT FLA FULL LOAD AMPERES GFI GROUND FAULT INTERRUPTER HP HORSEPOWER LTG LIGHTING NIC NOT IN CONTRACT NTS NOT TO SCALE NL UNSWITCHED NIGHT LIGHT PB PULL BOX UG UNDERGROUND UON UNLESS OTHERWISE NOTED VI_ VERIFY LOCATION WP WEAIFIER PROOF • PART 1 - GENERAL 1.0 GENERAL 1.1 SCOPE THE "GENERAL CONDITIONS OF THE CONTRACT" ARE A PART OF THIS SECTION AND SHALL BE AS BINDING AS IF REPRODUCED HEREIN. A. THE WORK UNDER THIS SECTION SHALL INCLUDE FURNISHING ALL LABOR, MATERIALS, TOOLS AND EQUIPMENT REQUIRED FOR THE COMPLETE INSTALLATION OF ALL ELECTRICAL WORK AS INDICATED ON THE ELECTRICAL DRAWINGS AND AS HEREINAFTER SPECIFIED, TOGETHER WITH OTHER ITEMS OF MISCELLANEOUS WORK SO INDICATED, EXCEPTING ONLY WORK CLEARLY INDICATED TO BE DONE UNDER OTHER SECTIONS OF THESE SPECIFICATIONS OR UNDER OTHER CONTRACTS. 1.2 CONTRACT DRAWINGS A. IN GENERAL, THE ELECTRICAL DRAWINGS ARE DIAGRAMATIC IN NATURE AND INDICATE THE LOCATION OF OUTLETS AND EQUIPMENT AND THEIR INTERCONNECTION; AND THOUGH NOT NECESSARILY INDICATING THE ACTUAL PROPER COORDINATION WITH THE WORK OF THEIR TRADES AND IN SPACE AVAILABLE WILL PERMIT. THE DRAWINGS ARE NOT INTENDED TO BE SCALED. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LIMITATIONS OF THE BUILDING STRUCTURE OR FINISH, AND TO THE MECHANICAL DRAWINGS FOR THE LOCATION OF EQUIPMENT OF THOSE TRADES REQUIREING ELECTRICAL SERVICE CONNECTIONS. ANY DISCREPENCY, CONFLICT, OR QUESTIONABLE POINT SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER BEFORE COMMENCING WORK. B. "PROVIDE" MEANS FURNISH, INSTALL, AND CONNECT UNLESS OTHERWISE NOTED, 1.3 RECORD DRAWINGS A. DURING THE PROGRESS OF THE WORK, MAINTAIN ONE COMPLETE SET OF RECORD DRAWINGS AS OUTLINED UNDER GENERAL NOTE 12. AS THE WORK IS INSTALLED, NEATLY AND CLEARLY MARK ON THESE PRINTS THE FOLLOWING INFORMATION: 1. ALL DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS. 2. INFORMATION CONTAINED ON CHANGE ORDERS. 3. DIMENSIONED LOCATIONS OF CONCEALED CONDUITS. 4. DIAGRAMS OF EQUIPMENT CONNECTIONS. AT THE CONCLUSION OF THE JOB, THESE PRINTS SHALL BE DELIVERED TO THE ARCHITECT, 1.4 CODES, PERMITS, AND INSPECTIONS A. NOTHING IN THESE SPECIFICATIONS OR ON THE DRAWINGS SHALL BE INTERPRETED AS PERMISSION TO VIOLATE CODES OR ORDINANCES. ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING, AND ALL OTHER APPLICABLE, CODES AND STANDARDS: 3. DETACH ALL EXISTING NONSUPPORTED CONDUITS, BOXES AND ELECTRICAL DIVICES PER CODE 4. EXTEND NEW WIRING AS REQUIRED TO NEW DEVICES AND OUTLETS. PART 2 - PRODUCTS B. INSPECT THE JOB SITE PRIOR TO SUBMITTING A BID AND MAKE ALLOWANCE FOR EXISTING CONDITIONS WHICH MAY AFFECT THE WORK AND ARRANGE FOR AND PAY FOR TESTS AND INSPECTIONS, AND PROVIDE NOTICES REQUIRED BY ANY AND ALL LAWS, RULES, REGULATIONS, AND ORDINANCES WHICH PERTAIN TO THIS WORK, WHERE ADDITIONS OR ALTERATIONS ARE REQUIRED IN OR AT EXISTING ELECTRICAL INSTALLATION AS INDICATED. 2.1 GENERAL: 1. STATE DIVISION OF INDUSTRIAL SAFETY, ELECTRICAL SAFETY ORDERS. 2. NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION. 3. UNDERWRITERS' LABORATORIES 4. LOCAL CODES AND INSPECTION AUTHORITIES. 5. NATIONAL ELECTRICAL CODE FOR ALL ITEMS NOT SPECIFICALLY COVERED BY STATE OR LOCAL ORDINANCES. 1, INFORMATION GIVEN ON THE DRAWINGS REGARDING EXISTING INSTALLATIONS OR CONDITIONS HAS BEEN OBTAINED FROM THE BEST SOURCES AVAILABLE BUT CANNOT BE GUARANTEED ACCURATE IN ALL RESPECTS. VERIFY ALL SUCH INFORMATION BEFORE PROCEEDING WITH ANY NEW WORK THAT MAY BE AFFECTED. INCLUDE AS A PART OF THE CONTRACT ALL WORK REQUIRED TO PRODUCE THE INDICATED RESULT. 2. RELOCATE AND /OR RECONNECT EXISTING CIRCUITS WHERE CONTINUITY HAS BEEN AFFECTED OR AS MAY BE REQUIRED TO PROVIDE FOR NEW CONSTRUCTION. A. ALL MATERIALS USED IN THE ELECTRICAL WORK HEREIN SPECIFIED SHALL BE NEW AND SUITED TO THE USE INTENDED AND SHALL BE LISTED BY THE UNDERWRITERS' LABORATORIES, INC., AND SHALL MEET THEIR REQUIREMENTS AND BEAR THEIR LABEL WHENEVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY FURNISHED BY THAT AGENCY. THE ARCHITECT RESERVES THE RIGHT TO REJECT ANY MATERIAL WHICH IN HIS OPINION IS NOT IN COMPLIANCE WITH THIS SPECIFICATION, EITHER BEFORE OR AFTER INSTALLATION. ALL MATERIALS SHALL BE OF THE TYPES OR MAKES HEREINAFTER SPECIFIED, AND NO SUBSTITUTIONS WILL BE PERMITTED WITHOUT SUBMITTAL FOR REVIEW BY THE ARCHITECT. "PRODUCTS" AND "MATERIALS" ARE USED INTERCHANGEABLY AND MEAN MATERIALS, FIXTURES AND EQUIPMENT. 2.2 CONDUIT A. PROVIDE ONLY NEW CONDUIT WITH UL LISTING OR LABEL AND DELIVER TO THE SITE IN STANDARD LENGTHS. UNLESS OTHERWISE INDICATED, PROVIDE CONDUITS FOR ALL TYPES OF CONDUCTORS OR CABLES OF ALL SYSTEMS AND VOLTAGES. 2.3 WIRE AND CABLE A. ALL WIRE AND CABLE SHALL BE ANNEALED COPPER WITH 98% CONDUCTIVITY AND 600 -VOLT INSULATION. 2.4 LIGHTING FIXTURES A. PROVIDE RECESSED, SURFACE AND PENDANT MOUNTED LIGHTING FIXTURES, COMPLETE WITH LAMPS, AND BALLASTS WHERE REQUIRED, AS SHOWN OF THE DRAWINGS AS SPECIFIED. 2.5 WRING DEVICES 2.6 NAMEPLATES 2.7 OUTLETS 2. PROVIDE LAMPS AS INDICATED ON THE DRAWINGS. 1. RIGID STEEL CONDUIT AND COUPLINGS: HOT - DIPPED GALVANIZED DR SHERARDIZED INSIDE AND OUT, WITH GALVANIZED THREADS. PROVIDE INSULATED METALLIC BUSHINGS EXCEPT THAT SIZES 1 INCH AND SMALLER MAY BE NONMETALLIC TYPE. 2. ELECTRICAL METALLIC STEEL TUBING: HOT- DIPPED GALVANIZED OR SHERARDIZED INSIDE AND OUT. PROVIDE INSULATED AND BUSHED TAP -ON TYPE CONNECTORS AND COUPLINGS AS MADE BY TOMIC OR T & B, OR WRENCH TIGHTENED SCREW TYPE. 3. FLEXIBLE CONDUIT: MANUFACTURED FROM ALUMINUM OR SINGLE STRIP GALVANIZED STEEL, PROVIDE INSULATED DIE -CAST CONNECTORS WITH RIDGES THAT THREAD INTO THE INSIDE OF THE CONDUIT TO INSURE A FORCE FIT AS MADE BY D & H ELECTRICAL COMPANY OR EQUAL 4. LIQUIDTIGHT FLEXIBLE CONDUIT: IDENTICAL TO FLEXIBLE STEEL CONDUIT BUT WITH OVERALL POLYVINYL CHLORIDE PLASTIC JACKET. PROVIDE INSULATING CONNECTORS, APPLETON 5TH SERIES OR EQUAL. 1. CONDUCTORS NO.10 AWG AND SMALLER SHALL BE SOLID TYPE THHN OR THW INSULATION: NO.8 AWG AND LARGER SHALL BE STRANDED TYPE THHN OR THW INSULATION. USE TYPE THW IN WET LOCATIONS, IN CONDUITS INSTALLED WITHIN OR JUST UNDER ROOFING MATERIALS AND FOR ALL AREAS EXTERIOR TO BUILDINGS. 2. CONDUCTORS INSTALLED IN AREAS SUBJECTED TO TEMPERATURES EXCEEDING 140 DEGREES F., TERMINATING IN INCANDESCENT LIGHTING FIXTURES, AND INSTALLED THROUGH OR INTO HOUSING CONTAINING BALLASTS, SHALL BE TYPE AVA. 3. FOR ALL SIZES, CONDUCTORS WITH MINERAL FILLED CROSSLINKED THERMOSETTING POLYETHYLENE INSULATION, UL TYPE XHHW RATED 75 DEGREES C. IN WET OR DRY LOCATIONS MAY BE USED. 1. FLUORESCENT BALLASTS OF PROPER TYPE AND CHARACTERISTICS FOR THE LAMPS IN THE FIXTURE AND WITH VOLTAGE RATING AS REQUIRED BY THE CIRCUIT WHICH THE FIXTURE IS CONNECTED. A. WIRING DEVICES SHALL BE OF NE MOWED COMPOSITION SPECIFICATION GRADE. ALL DEVICES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED AND WITH FINISH MATCHING DEVICE PLATES. LOCAL SWITCHES SHALL HAVE ALTERNATING CURRENT RATINGS EQUAL TO FULL NOMINAL CAPACITY. 1. RECEPTACLES: PROVIDE TYPE IN ACCORDANCE WITH NEMA STANDARD CONFIGURATION AS SHOWN. 2. SWITCHES: SINGLE POLE, 3 -WAY AND 4 -WAY AS SHOWN, FINISH AS SELECTED. 3. PROVIDE PLATES FOR ALL OUTLET BOXES AND FITTINGS OF ALL SYSTEMS EXCEPT AT OUTLETS WHERE FIXTURE CANOPIES ARE USED. A. PROVIDE A NAMEPLATE FOR EACH PANELBOARD, DISCONNECT SWITCH, AND FOR ANY OTHER CONTROL DEVICE OR MAJOR ITEM OF ELECTRICAL EQUIPMENT, AS FOLLOWS: 1. PROVIDE BLACK -ON -WHITE LAMINATED PLASTIC NAMEPLATES ENGRAVED IN 1/4" HIGH LETTERS TO CORRESPOND WITH THE DESIGNATIONS ON THE DRAWINGS. PROVIDE OTHER OR ADDITIONAL INFORMATION ON NAMEPLATES WHERE INDICATED. 2. ATTACH NAMEPLATES TO EQUIPMENT WITH RIVETS, BOLTS, OR APPLICABLE SHEET METAL SCREWS. GLUE -ON TYPES AND POPRIVET TYPES ARE NOT ACCEPTABLE. 3. PROVIDE DYMO TYPE PLASTIC TAPE FOR EACH RECEPTACLE AND J -BOX INDICATING CIRCUIT NUMBERS AND PANEL PROVIDE ADDITIONAL INFORMATION AS INDICATED ON THE DRAWINGS. THE COLOR CODE FOR THE TAPES SHALL BE AS FOLLOWS: A. ORANGE FOR ISOLATED GROUND CIRCUITS B. BLACK FOR STANDARD 120V CIRCUITS A. OUTLET AND JUNCTION BOXES USED IN CONCEALED WORK, SHALL BE GALVANIZED OR SHERARDIZED ONE- PIECE, PRESSED STEEL. KNOCK -OUT TYPE SIZED IN ACCORDANCE WITH THE CODE FOR THE NUMBER OF CONDUCTORS OR THE NUMBER AND SIZE OF CONDUITS ENTERING THE BOX, BUT SHALL NOT BE LESS THAN 4" SQUARE AND 1 -1/2" DEEP. PLASTER RINGS SHALL BE PROVIDED FOR ALL FLUSH MOUNTED BOXES. 2.8 SAFETY SWITCHES A. PROVIDE SWITCHES WITH THE NUMBER OF POLES AND THE VOLTAGE, CURRENT AND HORSEPOWER RATINGS AS REQUIRED. PROVIDE EXTERNALLY OPERABLE, QUICK -MAKE, QUICK -BREAK TYPE WITH COVER INTERLOCK AND PADLOCKABLE IN EITHER THE OPEN OR CLOSED POSITION. UNLESS INDICATED OTHERWISE, PROVIDE SWITCHES INDOORS IN NEMA TYPE 1 ENCLOSURE AND OUTDOORS, OR WHERE INDICATED TO BE WEATHERPROOF IN NEMA TYPE 3R RAIN -TIGHT ENCLOSURE. SWITCHES SHALL BE HEAVY -DUTY TYPE MEETING NEMA SPECIFICATIONS KS1 -2.02. PROVIDE NAMEPLATES INDICATING EQUIPMENT SERVED. PROVIDE UNIT AS MANUFACTURED BY GENERAL ELECTRIC, SQUARE -D OR CUTTLER - HAMMER. 2.9 PANELBOARD 2.10 A. 3.2 WIRE PROVIDE SURFACE MOUNTED PANELBOARD WITH MAIN LUGS, SUBFEED LUGS, BUS SIZE AND CIRCUIT BREAKERS OF A RATING AS SHOWN ON THE DRAWINGS. B. CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE WIN INTERRUPTING CAPACITY AS SHOWN ON THE PANEL SCHEDULE. SINGLE POLE BREAKERS SHALL BE FULL MODULE SIZE. MULTIPOLE BREAKERS SHALL BE OF THE COMMON TRIP TYPE HAVING A SINGLE HANDLE. C. PROVIDE NEATLY TYPED CIRCUIT DIRECTORY CARD, CLEARLY IDENTIFYING ALL CIRCUITS, MOUNTED IN A CARD HOLDER, BEHIND HEAVY PLASIC ON THE INSIDE OF THE HINGED DOOR D. PROVIDE PANELBOARDS MANUFACTURED BY "SQUARE D ", CUTTLER - HAMMER OR GENERAL ELECTRIC, TRANSFORMERS A. PROVIDE DRY TYPE, COPPER WINDING, SELF - COATED, VENTILAILO TRANSFORMERS FOR USE ON 60 -CYCLE SYSTEM WITH THE FOLLOWING CHARACTERISTICS: 1. RATINGS: PHASE. VOLTAGE AND CONNECTION ARRANGEMENT AS INDICATED. 2. INSULATION: CLASS H 115' C AVERAGE CONDUCTOR TEMPERATURE RISE. 3. TAPS: FOUR 2 -1/2 PERCENT PRIMARY TAPS, TWO ABOVE AND TWO BELOW RATED VOLTAGE. 4. MOUNTING: TRANSFORMERS SHALL BE FURNISHED COMPLETE WITH MOUNTING CHANNELS AND MOUNTING BOLTS. ENCLOSURES SHALL BE PROVIDED WITH LIFTING LUGS AND .LACKING PLATES AS REQUIRED. 5. VIBRATION DAMPENING: CONSTRUCTED WITH BUILT -IN VIBRATION DAMPERS WITCH COMPLETELY ISOLATE THE CORES AND COILS FROM ALL SUPPORTS AND ENCLOSURES. 6. SOUND RATINGS: IN THE INSTALLED CONDITION. THE SOUND LEVELS SHALL NOT EXCEED 50 DB. TRANSFORMERS SHALL BE MANUFACTURED BY SQUARE "D ", GENERAL ELECTRIC, CUTTLER- HAMMER OR WESTINGHOUSE. PART 3 - EXECUTION 3.1 MATERIALS AND WORKMANSHIP A. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH RECOMMENDATIONS OF THE MANUFACTURER TO CONFORM WITH THE CONTRACT DOCUMENTS. THE INSTALLATION SHALL BE ACCOMPLISHED IN CONFORMANCE WITH THE APPLICABLE RULES. AND WIRING METHODS A. ALL WIRING AND CABLE INCLUDING LOW VOLTAGE AND CONTROL CIRCUITS SHALL BE INSTALLED IN CONDUIT UNLESS OTHERWISE NOTED. 1. COLOR CODE ALL BRANCH CIRCUIT AND CONTROL CIRCUIT WIRING BY MEANS OF FACTORY COLOR CODED CONDUCTORS. EACH PHASE SHALL BE THE SAME COLOR THROUGHOUT THE SYSTEM AND SHALL BE A DIFFERENT COLOR FROM OTHER PHASES AND OTHER SYSTEMS THE IDENTIFIED NEUTRAL CONDUCTOR SHALL BE WHITE, AND GROUND WIRES SHALL BE GREEN. 3.3 CONDUIT AND TUBING A. EXCEPT WHEN OTHERWISE INDICATED AS MORE STRINGENT, PROVIDE THE TYPE OF CONDUIT LEGALLY PERMITTED OR REQUIRED FOR EACH LOCATION OR CONDITION. UNLESS INDICATED OTHERWISE, CONDUITS SHALL BE CONCEALED WHERE POSSIBLE WITHIN OR BEHIND FINISHED WALLS OR CEILINGS. 1. ELECTRICAL METALLIC TUBING (EMT) MAY BE INSTALLED ONLY WITHIN BUILDINGS ABOVE GRADE IN DRY LOCATIONS AND WHERE NOT SUBJECT TD MECHANICAL INJURY OR OTHERWISE PROHIBITED. 2. USE RIGID METAL CONDUIT WHERE LEGALLY REQUIRED, WHERE EXPOSED TO THE WEATHER; ALSO WHERE SUBJECT TO MECHANICAL INJURY, HERE DEFINED AS EXPOSED CONDUIT LESS THAN 7' -6" ABOVE THE FLOOR, WHERE UNDERGROUND, AND WHERE OTHER TYPES OF CONDUITS ARE NOT ALLOWED UNDER THIS SPECIFICATION. B. PROVIDE A GREEN INSULATION GROUNDING CONDUCTOR OF SIZE AS REQUIRED BY CODE IN ALL FLEXIBLE CONDUITS OR OTHER CONDUIT RUNS HAVING A LENGTH OF FLEXIBLE CONDUIT AS ANY PART OF THE RUN. USE FLEXIBLE CONDUIT ONLY AS FOLLOWS: A. WHERE INDICATED. B. FINAL CONNECTIONS TO MOTORS, TRANSFORMER, VIBRATING EQUIPMENT OR WHERE REQUIRED FOR EQUIPMENT SERVICING. C. CONNECTIONS TO RECESSED LIGHTING FIXTURES FROM NEARBY ACCESSIBLE JUNCTION BOXES. D. CONCEALED RUNS IN DRY LOCATIONS WHERE STRUCTURAL CONDITIONS PREVENT THE USE OF OTHER TYPES OF CONDUIT. E. IN DAMP LOCATIONS OR AREAS EXPOSED TO THE WEATHER, FLEXIBLE CONDUIT, WHERE REQUIRED, SHALL BE OF THE LIQUID -TIGHT TYPE PROVIDED THE JACKET TEMPERATURE LIMITATIONS WILL NOT BE EXCEEDED. C. SUPPORT CONDUIT AT LEGAL INTERVALS. PROVIDE ADDITIONAL SUPPORTS WHERE OBVIOUSLY REQUIRED OR AS DIRECTED. 3.4 LIGHTING FIXTURES 3.5 EQUIPMENT CONNECTIONS 3.6 TESTS 3.7 CUTTING AND PATCHING 4.0 WARRANTY A. FURNISH AND INSTALL FIXTURES COMPLETE IN CONFORMANCE WITH THE SPECIFICATION, THE REQUIREMENTS SPECIFIED BELOW, AND DETAILED ON THE DRAWINGS. DETAILS SHOWN ON THE DRAWINGS ARE INDICATIVE OF THE GENERAL TYPE DESIRED AND ARE NOT INTENDED TO RESTRICT SELECTION TO FIXTURES OF ANY PARTICULAR MANUFACTURER. (SUBMIT FOR ARCHITECTS APPROVAL) 1. LIGHTING FIXTURES SHALL BE SET PLUMB, SQUARE, LEVEL, AND IN ALIGNMENT AND SHALL BE SECURED IN ACCORDANCE WITH THE MANUFACTURERS' DIRECTIONS AND SHOP DRAWINGS EXCEPT AS OTHERWISE NOTED. ACCESSORIES SUCH AS STRAPS, MOUNTING PLATES, NIPPLES, OR BRACKETS SHALL BE PROVIDED FOR PROPER INSTALLATION. 2. FOR FLUORESCENT FIXTURES, THE CATALOG NUMBERS ARE THOSE FOR INDIVIDUAL UNITS. WHERE CONTINUOUS ROWS ARE INDICATED, PROVIDE ALL NECESSARY ACCESSORIES. WHERE SINGLE -LAMP FIXTURES ARE INDICATED IN CONTINUOUS ROWS PROVIDE TANDEM UNITS WITH 2 -LAMP BALLASTS WHEREVER POSSIBLE. 3. WHERE FIXTURES ARE FOR LAY -IN MOUNTING IN AN EXPOSED RUNNER TYPE OF CEILING, THE ADDITIONAL CEILING WIRE TIES FOR THE FIXTURES WILL BE PROVIDED AS PART OF THE CEILING WORK. THIS CONTRACTOR SHALL INSTALL AND TIE OFF EACH FIXTURE. IN SUCH CEILINGS OR SIMILAR, PROVIDE EACH FIXTURES WITH CLIPS (4 REQUIRED) OR EQUIVALENT MEANS TO PREVENT THE ACCIDENTAL DISENGAGEMENT OF THE FIXTURE FROM THE CEILING. 4. LAMPS OF THE PROPER SIZE, TYPE, WATTAGE, AND VOLTAGE RATINGS AS INDICATED ON THE DRAWINGS SHALL BE DELIVERED TO THE PROJECT IN THE ORIGINAL CARTONS AND INSTALLED IN THE FIXTURES JUST PRIOR TO THE COMPLETION OF THE PROJECT. LAMPS THAT HAVE BEEN USED DURING THE CONSTRUCTION SHALL BE REPLACED WITH NEW UNITS SO AS TO ASSURE A NEW INSTALLATION AT THE TIME OF FINAL ACCEPTANCE. A. ALL WIRING FOR THE CONNECTION OF MOTORS AND CONTROL EQUIPMENT AS INDICATED ON THE DRAWING SHALL BE FURNISHED AND INSTALLED UNDER THIS SECTION OF THESE SPECIFICATIONS. B. FLEXIBLE CONNECTIONS OF SHORT LENGTH SHALL BE PROVIDED FOR EQUIPMENT SUBJECT TO VIBRATION OR MOVEMENT AND FOR ALL MOTORS. LIQUID -TIGHT FLEXIBLY CONDUIT SHALL BE USED IN WET LOCATIONS. A SEPARATE GROUND CONDUCTOR SHALL BE PROVIDED ACROSS ALL FLEXIBLE CONNECTIONS. A. IN ADDITION TO TEXTS REQUIRED BY OTHER SECTIONS, PERFORM OR CAUSE TO BE PERFORMED, ANY TESTS SPECIFIED FOR ELECTRICAL WORK WHEN THE WORK IS SUBSTANTIALLY COMPLETE, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. UPON COMPLETION OF THE WORK AND ADJUSTMENT OF ALL EQUIPMENT, CONDUCT AN OPERATING TEST AND SUBMIT FOR APPROVAL AT SUCH TIME AS THE ARCHITECT DIRECTS. CONDUCT THE TEXT IN THE PRESENCE OF AN AUTHORIZED REPRESENTATIVE OF THE ARCHITECT. DEMONSTRATE THAT ALL SYSTEMS AND EQUIPMENT ARE: A. OPERATING IN ACCORDANCE WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. B. FREE FROM ALL ELECTRICAL AND MECHANICAL DEFECTS. C. FREE FROM SHORT CIRCUITS AND GROUNDS OTHER THAN INTENTIONAL GROUNDS. 2. CONDUCT ALL OTHER AND ADDITIONAL TESTS THAT ARE REQUIRED BY AUTHORITIES HAVING JURISDICTION OR ARE REQUESTED BY THE ARCHITECT. 3. ALL COSTS INCURRED, INCLUDING REQUIRED INSTRUMENTS AND PERSONNEL FOR THE TESTS, SHALL BE PAID FOR BY THE CONTRACTOR. A, BE RESPONSIBLE FOR THE CUTTING AND PATCHING OF ROUGH OR FINISH WORK REQUIRED BY THIS INSTALLATION. PATCHING SHALL BE OF THE SAME MATERIAL, FINISH AND WORKMANSHIP AS THE ORIGINAL WORK, AND WHEN REQUIRED BY THE ARCHITECT, DONE BY MECHANICS OF THE ORIGINAL TRADE AT CONTRACTOR'S EXPENSE. A. UNCONDITIONALLY WARRANT FOR ONE YEAR EVERY PART OF THE WORK EXCEPT THAT FLOURESCENT BALLASTS SHALL BE WARRANTED FOR (2) YEARS. FURNISH MANUFACTURERS' WARRANTIES. ALL WARRANTIES SHALL START FROM THE TIME OF ACCEPTANCE OF THE COMPLETED PROJECT BY THE OWNER. NOTE TO THE CONTRACTOR: DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. poi -410b 4 RECEIVED CITY OF TUKWILA DEC 19 2007 PERMIT CENi7Ef "A °41 1 - \ rid 4 ---, \ 117 ■OPYA %Ali associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415-362-5044 BARE ESCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (DR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE I 10/12/07 12/07/07 \ DESCRIPTION DD SET CD SET / 4i L� j ' : r - x o S ��JSI p14786 ' N � � t �, ~ % 4 I I Souti ter Park 98188 -c ig County I I I I PROJ. NO.: 7112 PM: A.M. JC: A.C. CHECKED: SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: SYMBOLS AND NOTES . -1 PART 1 - GENERAL 1.0 GENERAL 1.1 SCOPE THE "GENERAL CONDITIONS OF THE CONTRACT" ARE A PART OF THIS SECTION AND SHALL BE AS BINDING AS IF REPRODUCED HEREIN. A. THE WORK UNDER THIS SECTION SHALL INCLUDE FURNISHING ALL LABOR, MATERIALS, TOOLS AND EQUIPMENT REQUIRED FOR THE COMPLETE INSTALLATION OF ALL ELECTRICAL WORK AS INDICATED ON THE ELECTRICAL DRAWINGS AND AS HEREINAFTER SPECIFIED, TOGETHER WITH OTHER ITEMS OF MISCELLANEOUS WORK SO INDICATED, EXCEPTING ONLY WORK CLEARLY INDICATED TO BE DONE UNDER OTHER SECTIONS OF THESE SPECIFICATIONS OR UNDER OTHER CONTRACTS. 1.2 CONTRACT DRAWINGS A. IN GENERAL, THE ELECTRICAL DRAWINGS ARE DIAGRAMATIC IN NATURE AND INDICATE THE LOCATION OF OUTLETS AND EQUIPMENT AND THEIR INTERCONNECTION; AND THOUGH NOT NECESSARILY INDICATING THE ACTUAL PROPER COORDINATION WITH THE WORK OF THEIR TRADES AND IN SPACE AVAILABLE WILL PERMIT. THE DRAWINGS ARE NOT INTENDED TO BE SCALED. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LIMITATIONS OF THE BUILDING STRUCTURE OR FINISH, AND TO THE MECHANICAL DRAWINGS FOR THE LOCATION OF EQUIPMENT OF THOSE TRADES REQUIREING ELECTRICAL SERVICE CONNECTIONS. ANY DISCREPENCY, CONFLICT, OR QUESTIONABLE POINT SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER BEFORE COMMENCING WORK. B. "PROVIDE" MEANS FURNISH, INSTALL, AND CONNECT UNLESS OTHERWISE NOTED, 1.3 RECORD DRAWINGS A. DURING THE PROGRESS OF THE WORK, MAINTAIN ONE COMPLETE SET OF RECORD DRAWINGS AS OUTLINED UNDER GENERAL NOTE 12. AS THE WORK IS INSTALLED, NEATLY AND CLEARLY MARK ON THESE PRINTS THE FOLLOWING INFORMATION: 1. ALL DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS. 2. INFORMATION CONTAINED ON CHANGE ORDERS. 3. DIMENSIONED LOCATIONS OF CONCEALED CONDUITS. 4. DIAGRAMS OF EQUIPMENT CONNECTIONS. AT THE CONCLUSION OF THE JOB, THESE PRINTS SHALL BE DELIVERED TO THE ARCHITECT, 1.4 CODES, PERMITS, AND INSPECTIONS A. NOTHING IN THESE SPECIFICATIONS OR ON THE DRAWINGS SHALL BE INTERPRETED AS PERMISSION TO VIOLATE CODES OR ORDINANCES. ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING, AND ALL OTHER APPLICABLE, CODES AND STANDARDS: 3. DETACH ALL EXISTING NONSUPPORTED CONDUITS, BOXES AND ELECTRICAL DIVICES PER CODE 4. EXTEND NEW WIRING AS REQUIRED TO NEW DEVICES AND OUTLETS. PART 2 - PRODUCTS B. INSPECT THE JOB SITE PRIOR TO SUBMITTING A BID AND MAKE ALLOWANCE FOR EXISTING CONDITIONS WHICH MAY AFFECT THE WORK AND ARRANGE FOR AND PAY FOR TESTS AND INSPECTIONS, AND PROVIDE NOTICES REQUIRED BY ANY AND ALL LAWS, RULES, REGULATIONS, AND ORDINANCES WHICH PERTAIN TO THIS WORK, WHERE ADDITIONS OR ALTERATIONS ARE REQUIRED IN OR AT EXISTING ELECTRICAL INSTALLATION AS INDICATED. 2.1 GENERAL: 1. STATE DIVISION OF INDUSTRIAL SAFETY, ELECTRICAL SAFETY ORDERS. 2. NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION. 3. UNDERWRITERS' LABORATORIES 4. LOCAL CODES AND INSPECTION AUTHORITIES. 5. NATIONAL ELECTRICAL CODE FOR ALL ITEMS NOT SPECIFICALLY COVERED BY STATE OR LOCAL ORDINANCES. 1, INFORMATION GIVEN ON THE DRAWINGS REGARDING EXISTING INSTALLATIONS OR CONDITIONS HAS BEEN OBTAINED FROM THE BEST SOURCES AVAILABLE BUT CANNOT BE GUARANTEED ACCURATE IN ALL RESPECTS. VERIFY ALL SUCH INFORMATION BEFORE PROCEEDING WITH ANY NEW WORK THAT MAY BE AFFECTED. INCLUDE AS A PART OF THE CONTRACT ALL WORK REQUIRED TO PRODUCE THE INDICATED RESULT. 2. RELOCATE AND /OR RECONNECT EXISTING CIRCUITS WHERE CONTINUITY HAS BEEN AFFECTED OR AS MAY BE REQUIRED TO PROVIDE FOR NEW CONSTRUCTION. A. ALL MATERIALS USED IN THE ELECTRICAL WORK HEREIN SPECIFIED SHALL BE NEW AND SUITED TO THE USE INTENDED AND SHALL BE LISTED BY THE UNDERWRITERS' LABORATORIES, INC., AND SHALL MEET THEIR REQUIREMENTS AND BEAR THEIR LABEL WHENEVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY FURNISHED BY THAT AGENCY. THE ARCHITECT RESERVES THE RIGHT TO REJECT ANY MATERIAL WHICH IN HIS OPINION IS NOT IN COMPLIANCE WITH THIS SPECIFICATION, EITHER BEFORE OR AFTER INSTALLATION. ALL MATERIALS SHALL BE OF THE TYPES OR MAKES HEREINAFTER SPECIFIED, AND NO SUBSTITUTIONS WILL BE PERMITTED WITHOUT SUBMITTAL FOR REVIEW BY THE ARCHITECT. "PRODUCTS" AND "MATERIALS" ARE USED INTERCHANGEABLY AND MEAN MATERIALS, FIXTURES AND EQUIPMENT. 2.2 CONDUIT A. PROVIDE ONLY NEW CONDUIT WITH UL LISTING OR LABEL AND DELIVER TO THE SITE IN STANDARD LENGTHS. UNLESS OTHERWISE INDICATED, PROVIDE CONDUITS FOR ALL TYPES OF CONDUCTORS OR CABLES OF ALL SYSTEMS AND VOLTAGES. 2.3 WIRE AND CABLE A. ALL WIRE AND CABLE SHALL BE ANNEALED COPPER WITH 98% CONDUCTIVITY AND 600 -VOLT INSULATION. 2.4 LIGHTING FIXTURES A. PROVIDE RECESSED, SURFACE AND PENDANT MOUNTED LIGHTING FIXTURES, COMPLETE WITH LAMPS, AND BALLASTS WHERE REQUIRED, AS SHOWN OF THE DRAWINGS AS SPECIFIED. 2.5 WRING DEVICES 2.6 NAMEPLATES 2.7 OUTLETS 2. PROVIDE LAMPS AS INDICATED ON THE DRAWINGS. 1. RIGID STEEL CONDUIT AND COUPLINGS: HOT - DIPPED GALVANIZED DR SHERARDIZED INSIDE AND OUT, WITH GALVANIZED THREADS. PROVIDE INSULATED METALLIC BUSHINGS EXCEPT THAT SIZES 1 INCH AND SMALLER MAY BE NONMETALLIC TYPE. 2. ELECTRICAL METALLIC STEEL TUBING: HOT- DIPPED GALVANIZED OR SHERARDIZED INSIDE AND OUT. PROVIDE INSULATED AND BUSHED TAP -ON TYPE CONNECTORS AND COUPLINGS AS MADE BY TOMIC OR T & B, OR WRENCH TIGHTENED SCREW TYPE. 3. FLEXIBLE CONDUIT: MANUFACTURED FROM ALUMINUM OR SINGLE STRIP GALVANIZED STEEL, PROVIDE INSULATED DIE -CAST CONNECTORS WITH RIDGES THAT THREAD INTO THE INSIDE OF THE CONDUIT TO INSURE A FORCE FIT AS MADE BY D & H ELECTRICAL COMPANY OR EQUAL 4. LIQUIDTIGHT FLEXIBLE CONDUIT: IDENTICAL TO FLEXIBLE STEEL CONDUIT BUT WITH OVERALL POLYVINYL CHLORIDE PLASTIC JACKET. PROVIDE INSULATING CONNECTORS, APPLETON 5TH SERIES OR EQUAL. 1. CONDUCTORS NO.10 AWG AND SMALLER SHALL BE SOLID TYPE THHN OR THW INSULATION: NO.8 AWG AND LARGER SHALL BE STRANDED TYPE THHN OR THW INSULATION. USE TYPE THW IN WET LOCATIONS, IN CONDUITS INSTALLED WITHIN OR JUST UNDER ROOFING MATERIALS AND FOR ALL AREAS EXTERIOR TO BUILDINGS. 2. CONDUCTORS INSTALLED IN AREAS SUBJECTED TO TEMPERATURES EXCEEDING 140 DEGREES F., TERMINATING IN INCANDESCENT LIGHTING FIXTURES, AND INSTALLED THROUGH OR INTO HOUSING CONTAINING BALLASTS, SHALL BE TYPE AVA. 3. FOR ALL SIZES, CONDUCTORS WITH MINERAL FILLED CROSSLINKED THERMOSETTING POLYETHYLENE INSULATION, UL TYPE XHHW RATED 75 DEGREES C. IN WET OR DRY LOCATIONS MAY BE USED. 1. FLUORESCENT BALLASTS OF PROPER TYPE AND CHARACTERISTICS FOR THE LAMPS IN THE FIXTURE AND WITH VOLTAGE RATING AS REQUIRED BY THE CIRCUIT WHICH THE FIXTURE IS CONNECTED. A. WIRING DEVICES SHALL BE OF NE MOWED COMPOSITION SPECIFICATION GRADE. ALL DEVICES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED AND WITH FINISH MATCHING DEVICE PLATES. LOCAL SWITCHES SHALL HAVE ALTERNATING CURRENT RATINGS EQUAL TO FULL NOMINAL CAPACITY. 1. RECEPTACLES: PROVIDE TYPE IN ACCORDANCE WITH NEMA STANDARD CONFIGURATION AS SHOWN. 2. SWITCHES: SINGLE POLE, 3 -WAY AND 4 -WAY AS SHOWN, FINISH AS SELECTED. 3. PROVIDE PLATES FOR ALL OUTLET BOXES AND FITTINGS OF ALL SYSTEMS EXCEPT AT OUTLETS WHERE FIXTURE CANOPIES ARE USED. A. PROVIDE A NAMEPLATE FOR EACH PANELBOARD, DISCONNECT SWITCH, AND FOR ANY OTHER CONTROL DEVICE OR MAJOR ITEM OF ELECTRICAL EQUIPMENT, AS FOLLOWS: 1. PROVIDE BLACK -ON -WHITE LAMINATED PLASTIC NAMEPLATES ENGRAVED IN 1/4" HIGH LETTERS TO CORRESPOND WITH THE DESIGNATIONS ON THE DRAWINGS. PROVIDE OTHER OR ADDITIONAL INFORMATION ON NAMEPLATES WHERE INDICATED. 2. ATTACH NAMEPLATES TO EQUIPMENT WITH RIVETS, BOLTS, OR APPLICABLE SHEET METAL SCREWS. GLUE -ON TYPES AND POPRIVET TYPES ARE NOT ACCEPTABLE. 3. PROVIDE DYMO TYPE PLASTIC TAPE FOR EACH RECEPTACLE AND J -BOX INDICATING CIRCUIT NUMBERS AND PANEL PROVIDE ADDITIONAL INFORMATION AS INDICATED ON THE DRAWINGS. THE COLOR CODE FOR THE TAPES SHALL BE AS FOLLOWS: A. ORANGE FOR ISOLATED GROUND CIRCUITS B. BLACK FOR STANDARD 120V CIRCUITS A. OUTLET AND JUNCTION BOXES USED IN CONCEALED WORK, SHALL BE GALVANIZED OR SHERARDIZED ONE- PIECE, PRESSED STEEL. KNOCK -OUT TYPE SIZED IN ACCORDANCE WITH THE CODE FOR THE NUMBER OF CONDUCTORS OR THE NUMBER AND SIZE OF CONDUITS ENTERING THE BOX, BUT SHALL NOT BE LESS THAN 4" SQUARE AND 1 -1/2" DEEP. PLASTER RINGS SHALL BE PROVIDED FOR ALL FLUSH MOUNTED BOXES. 2.8 SAFETY SWITCHES A. PROVIDE SWITCHES WITH THE NUMBER OF POLES AND THE VOLTAGE, CURRENT AND HORSEPOWER RATINGS AS REQUIRED. PROVIDE EXTERNALLY OPERABLE, QUICK -MAKE, QUICK -BREAK TYPE WITH COVER INTERLOCK AND PADLOCKABLE IN EITHER THE OPEN OR CLOSED POSITION. UNLESS INDICATED OTHERWISE, PROVIDE SWITCHES INDOORS IN NEMA TYPE 1 ENCLOSURE AND OUTDOORS, OR WHERE INDICATED TO BE WEATHERPROOF IN NEMA TYPE 3R RAIN -TIGHT ENCLOSURE. SWITCHES SHALL BE HEAVY -DUTY TYPE MEETING NEMA SPECIFICATIONS KS1 -2.02. PROVIDE NAMEPLATES INDICATING EQUIPMENT SERVED. PROVIDE UNIT AS MANUFACTURED BY GENERAL ELECTRIC, SQUARE -D OR CUTTLER - HAMMER. 2.9 PANELBOARD 2.10 A. 3.2 WIRE PROVIDE SURFACE MOUNTED PANELBOARD WITH MAIN LUGS, SUBFEED LUGS, BUS SIZE AND CIRCUIT BREAKERS OF A RATING AS SHOWN ON THE DRAWINGS. B. CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE WIN INTERRUPTING CAPACITY AS SHOWN ON THE PANEL SCHEDULE. SINGLE POLE BREAKERS SHALL BE FULL MODULE SIZE. MULTIPOLE BREAKERS SHALL BE OF THE COMMON TRIP TYPE HAVING A SINGLE HANDLE. C. PROVIDE NEATLY TYPED CIRCUIT DIRECTORY CARD, CLEARLY IDENTIFYING ALL CIRCUITS, MOUNTED IN A CARD HOLDER, BEHIND HEAVY PLASIC ON THE INSIDE OF THE HINGED DOOR D. PROVIDE PANELBOARDS MANUFACTURED BY "SQUARE D ", CUTTLER - HAMMER OR GENERAL ELECTRIC, TRANSFORMERS A. PROVIDE DRY TYPE, COPPER WINDING, SELF - COATED, VENTILAILO TRANSFORMERS FOR USE ON 60 -CYCLE SYSTEM WITH THE FOLLOWING CHARACTERISTICS: 1. RATINGS: PHASE. VOLTAGE AND CONNECTION ARRANGEMENT AS INDICATED. 2. INSULATION: CLASS H 115' C AVERAGE CONDUCTOR TEMPERATURE RISE. 3. TAPS: FOUR 2 -1/2 PERCENT PRIMARY TAPS, TWO ABOVE AND TWO BELOW RATED VOLTAGE. 4. MOUNTING: TRANSFORMERS SHALL BE FURNISHED COMPLETE WITH MOUNTING CHANNELS AND MOUNTING BOLTS. ENCLOSURES SHALL BE PROVIDED WITH LIFTING LUGS AND .LACKING PLATES AS REQUIRED. 5. VIBRATION DAMPENING: CONSTRUCTED WITH BUILT -IN VIBRATION DAMPERS WITCH COMPLETELY ISOLATE THE CORES AND COILS FROM ALL SUPPORTS AND ENCLOSURES. 6. SOUND RATINGS: IN THE INSTALLED CONDITION. THE SOUND LEVELS SHALL NOT EXCEED 50 DB. TRANSFORMERS SHALL BE MANUFACTURED BY SQUARE "D ", GENERAL ELECTRIC, CUTTLER- HAMMER OR WESTINGHOUSE. PART 3 - EXECUTION 3.1 MATERIALS AND WORKMANSHIP A. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH RECOMMENDATIONS OF THE MANUFACTURER TO CONFORM WITH THE CONTRACT DOCUMENTS. THE INSTALLATION SHALL BE ACCOMPLISHED IN CONFORMANCE WITH THE APPLICABLE RULES. AND WIRING METHODS A. ALL WIRING AND CABLE INCLUDING LOW VOLTAGE AND CONTROL CIRCUITS SHALL BE INSTALLED IN CONDUIT UNLESS OTHERWISE NOTED. 1. COLOR CODE ALL BRANCH CIRCUIT AND CONTROL CIRCUIT WIRING BY MEANS OF FACTORY COLOR CODED CONDUCTORS. EACH PHASE SHALL BE THE SAME COLOR THROUGHOUT THE SYSTEM AND SHALL BE A DIFFERENT COLOR FROM OTHER PHASES AND OTHER SYSTEMS THE IDENTIFIED NEUTRAL CONDUCTOR SHALL BE WHITE, AND GROUND WIRES SHALL BE GREEN. 3.3 CONDUIT AND TUBING A. EXCEPT WHEN OTHERWISE INDICATED AS MORE STRINGENT, PROVIDE THE TYPE OF CONDUIT LEGALLY PERMITTED OR REQUIRED FOR EACH LOCATION OR CONDITION. UNLESS INDICATED OTHERWISE, CONDUITS SHALL BE CONCEALED WHERE POSSIBLE WITHIN OR BEHIND FINISHED WALLS OR CEILINGS. 1. ELECTRICAL METALLIC TUBING (EMT) MAY BE INSTALLED ONLY WITHIN BUILDINGS ABOVE GRADE IN DRY LOCATIONS AND WHERE NOT SUBJECT TD MECHANICAL INJURY OR OTHERWISE PROHIBITED. 2. USE RIGID METAL CONDUIT WHERE LEGALLY REQUIRED, WHERE EXPOSED TO THE WEATHER; ALSO WHERE SUBJECT TO MECHANICAL INJURY, HERE DEFINED AS EXPOSED CONDUIT LESS THAN 7' -6" ABOVE THE FLOOR, WHERE UNDERGROUND, AND WHERE OTHER TYPES OF CONDUITS ARE NOT ALLOWED UNDER THIS SPECIFICATION. B. PROVIDE A GREEN INSULATION GROUNDING CONDUCTOR OF SIZE AS REQUIRED BY CODE IN ALL FLEXIBLE CONDUITS OR OTHER CONDUIT RUNS HAVING A LENGTH OF FLEXIBLE CONDUIT AS ANY PART OF THE RUN. USE FLEXIBLE CONDUIT ONLY AS FOLLOWS: A. WHERE INDICATED. B. FINAL CONNECTIONS TO MOTORS, TRANSFORMER, VIBRATING EQUIPMENT OR WHERE REQUIRED FOR EQUIPMENT SERVICING. C. CONNECTIONS TO RECESSED LIGHTING FIXTURES FROM NEARBY ACCESSIBLE JUNCTION BOXES. D. CONCEALED RUNS IN DRY LOCATIONS WHERE STRUCTURAL CONDITIONS PREVENT THE USE OF OTHER TYPES OF CONDUIT. E. IN DAMP LOCATIONS OR AREAS EXPOSED TO THE WEATHER, FLEXIBLE CONDUIT, WHERE REQUIRED, SHALL BE OF THE LIQUID -TIGHT TYPE PROVIDED THE JACKET TEMPERATURE LIMITATIONS WILL NOT BE EXCEEDED. C. SUPPORT CONDUIT AT LEGAL INTERVALS. PROVIDE ADDITIONAL SUPPORTS WHERE OBVIOUSLY REQUIRED OR AS DIRECTED. 3.4 LIGHTING FIXTURES 3.5 EQUIPMENT CONNECTIONS 3.6 TESTS 3.7 CUTTING AND PATCHING 4.0 WARRANTY A. FURNISH AND INSTALL FIXTURES COMPLETE IN CONFORMANCE WITH THE SPECIFICATION, THE REQUIREMENTS SPECIFIED BELOW, AND DETAILED ON THE DRAWINGS. DETAILS SHOWN ON THE DRAWINGS ARE INDICATIVE OF THE GENERAL TYPE DESIRED AND ARE NOT INTENDED TO RESTRICT SELECTION TO FIXTURES OF ANY PARTICULAR MANUFACTURER. (SUBMIT FOR ARCHITECTS APPROVAL) 1. LIGHTING FIXTURES SHALL BE SET PLUMB, SQUARE, LEVEL, AND IN ALIGNMENT AND SHALL BE SECURED IN ACCORDANCE WITH THE MANUFACTURERS' DIRECTIONS AND SHOP DRAWINGS EXCEPT AS OTHERWISE NOTED. ACCESSORIES SUCH AS STRAPS, MOUNTING PLATES, NIPPLES, OR BRACKETS SHALL BE PROVIDED FOR PROPER INSTALLATION. 2. FOR FLUORESCENT FIXTURES, THE CATALOG NUMBERS ARE THOSE FOR INDIVIDUAL UNITS. WHERE CONTINUOUS ROWS ARE INDICATED, PROVIDE ALL NECESSARY ACCESSORIES. WHERE SINGLE -LAMP FIXTURES ARE INDICATED IN CONTINUOUS ROWS PROVIDE TANDEM UNITS WITH 2 -LAMP BALLASTS WHEREVER POSSIBLE. 3. WHERE FIXTURES ARE FOR LAY -IN MOUNTING IN AN EXPOSED RUNNER TYPE OF CEILING, THE ADDITIONAL CEILING WIRE TIES FOR THE FIXTURES WILL BE PROVIDED AS PART OF THE CEILING WORK. THIS CONTRACTOR SHALL INSTALL AND TIE OFF EACH FIXTURE. IN SUCH CEILINGS OR SIMILAR, PROVIDE EACH FIXTURES WITH CLIPS (4 REQUIRED) OR EQUIVALENT MEANS TO PREVENT THE ACCIDENTAL DISENGAGEMENT OF THE FIXTURE FROM THE CEILING. 4. LAMPS OF THE PROPER SIZE, TYPE, WATTAGE, AND VOLTAGE RATINGS AS INDICATED ON THE DRAWINGS SHALL BE DELIVERED TO THE PROJECT IN THE ORIGINAL CARTONS AND INSTALLED IN THE FIXTURES JUST PRIOR TO THE COMPLETION OF THE PROJECT. LAMPS THAT HAVE BEEN USED DURING THE CONSTRUCTION SHALL BE REPLACED WITH NEW UNITS SO AS TO ASSURE A NEW INSTALLATION AT THE TIME OF FINAL ACCEPTANCE. A. ALL WIRING FOR THE CONNECTION OF MOTORS AND CONTROL EQUIPMENT AS INDICATED ON THE DRAWING SHALL BE FURNISHED AND INSTALLED UNDER THIS SECTION OF THESE SPECIFICATIONS. B. FLEXIBLE CONNECTIONS OF SHORT LENGTH SHALL BE PROVIDED FOR EQUIPMENT SUBJECT TO VIBRATION OR MOVEMENT AND FOR ALL MOTORS. LIQUID -TIGHT FLEXIBLY CONDUIT SHALL BE USED IN WET LOCATIONS. A SEPARATE GROUND CONDUCTOR SHALL BE PROVIDED ACROSS ALL FLEXIBLE CONNECTIONS. A. IN ADDITION TO TEXTS REQUIRED BY OTHER SECTIONS, PERFORM OR CAUSE TO BE PERFORMED, ANY TESTS SPECIFIED FOR ELECTRICAL WORK WHEN THE WORK IS SUBSTANTIALLY COMPLETE, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. UPON COMPLETION OF THE WORK AND ADJUSTMENT OF ALL EQUIPMENT, CONDUCT AN OPERATING TEST AND SUBMIT FOR APPROVAL AT SUCH TIME AS THE ARCHITECT DIRECTS. CONDUCT THE TEXT IN THE PRESENCE OF AN AUTHORIZED REPRESENTATIVE OF THE ARCHITECT. DEMONSTRATE THAT ALL SYSTEMS AND EQUIPMENT ARE: A. OPERATING IN ACCORDANCE WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. B. FREE FROM ALL ELECTRICAL AND MECHANICAL DEFECTS. C. FREE FROM SHORT CIRCUITS AND GROUNDS OTHER THAN INTENTIONAL GROUNDS. 2. CONDUCT ALL OTHER AND ADDITIONAL TESTS THAT ARE REQUIRED BY AUTHORITIES HAVING JURISDICTION OR ARE REQUESTED BY THE ARCHITECT. 3. ALL COSTS INCURRED, INCLUDING REQUIRED INSTRUMENTS AND PERSONNEL FOR THE TESTS, SHALL BE PAID FOR BY THE CONTRACTOR. A, BE RESPONSIBLE FOR THE CUTTING AND PATCHING OF ROUGH OR FINISH WORK REQUIRED BY THIS INSTALLATION. PATCHING SHALL BE OF THE SAME MATERIAL, FINISH AND WORKMANSHIP AS THE ORIGINAL WORK, AND WHEN REQUIRED BY THE ARCHITECT, DONE BY MECHANICS OF THE ORIGINAL TRADE AT CONTRACTOR'S EXPENSE. A. UNCONDITIONALLY WARRANT FOR ONE YEAR EVERY PART OF THE WORK EXCEPT THAT FLOURESCENT BALLASTS SHALL BE WARRANTED FOR (2) YEARS. FURNISH MANUFACTURERS' WARRANTIES. ALL WARRANTIES SHALL START FROM THE TIME OF ACCEPTANCE OF THE COMPLETED PROJECT BY THE OWNER. NOTE TO THE CONTRACTOR: DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. poi -410b 4 RECEIVED CITY OF TUKWILA DEC 19 2007 PERMIT CENi7Ef 120/208 S 10000 A.I.C. R PANEL: "LA" MAIN 100A C.B. (W/ GND. BUS) FLUSH MOUNT CT No C.B. OUTLETS LOAD (VA) L.C.L LOAD DESCRIPTION AMP P LTG REC ETC L -1 L -2 L -3 1 20 1 24 768 / / % / / // GENERAL LTG. 3 20 1 36 7 � 1152 / //, 5 20 1 19 /��� 836 7 20 1 23 1012 j 9 20 1 38 / 1184 „/ 11 20 1 20 j /���� 460 460 13 20 1 9 700 / //' T 15 20 1 0 /i SPARE 17 20 1 5 3 390 /� 220 220 NL & EXIT SIGNS CSTOCKROOM 7 1 21 20 1 1 j/�ff 600 / /// SECURITY 23 20 1 1 1100 SHOW WINDOW 25 20 1 2 600 ` //� DOOR HOLDERS 27 20 1 4 / j 720 ,��, GENERAL RECEPT. 29 20 1 1 300 SPRINKLER CONTROLLER 31 20 1 4 720 //� GENERAL RECEPT. 33 20 1 1 f 600 j /�, 600 PLASMA TV 35 20 1 f /� 0 SPARE 37 20 1 0 //� /, SPARE 39 20 1 / 0 ,� SPARE 41 20 1 %//// // 0 SPARE 2 20 1 360 / / /// OFFICE 4 20 1 //7-- / 600 / � TELE. BKBD. 20 1 ,, 9 STOCKROOM RESTROOM 8 10 20 20 1 1 1 1200 / / / / /i: 15_0 4 v �� _ A_ // % REFRIGERATOR 12 20 1 " 1200 MICROWAVE 14 20 1 2 600 . •. . 16 20 2 1 1150 EWH -1 18 � - - 1150 - - -- 20 20 1 1 500 9/ WATER METER 22 20 1 / 0 ,A1 SPARE 24 20 1//� 300 1 SPARE 26 20 1 0 ��� SPARE 28 0 20 j� /� 0 32 20 1 0 34 20 1 0 0 36 20 1 / � 0 38 20 1 01� 40 20 1 0 M 42 20 1 j / / / /// 0 TOTAL LOAD AND SPARE 25% OF L.C.L TOTAL 6850 6806 6466 8522 V, 3 PH = 62 AMPS 20122 VA. 2131 VA. 22253 VA. © 120/208 SPECIFIC NOTES 1 2 3 4 EXISTING MAIN SWITCHBOARD WITH ASSOCIATED SEVICES TO REMAIN. VERIFY AT THE SITE. VERIFY EXACT LOCATION OF EXISTING 480V, 200A, 3P DISCONNECT SWITCH PROVIDED BY LANDLORD, INSTALL A GUTTER AS SHOWN. VERIFY EXACT LOCATION AT THE SITE. PROVIDE 480V, 60A, 3P DISCONNECT SWITCH WITH 40A CLASS RK -1 FUSES FOR CONNECTION TO NEW TRANSFORMER AS SHOWN. NEW 30 KVA, 480V -- 120/208V, 30, 4W, COPPER WINDING DRY TYPE TRANSFORMER TO BE MOUNTED ON WALL ABOVE PANEL "LA ". PROVIDE ALL REQUIRED MOUNTING HARDWARE PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE 3/4 "C, 1 #6 GND., CONNECT TO BLDG GND. STEEL STRUCTURE AND BOND TO MAIN COLD WATER PIPE. GUTTER PANEL "LA" A. B. C. D. E. F. 200A 3P <10' EXISTING FEEDER 3/4 "C, 3 #8 1 1/2"C, 4 #1 +1 #6 GND. <10' "TA" 30 KVA 480V- 120/208V SINGLE LINE DIAGRAM NOTE: ALL ITEMS ARE NEW U.O.N. 1 —LINE NOTES ALL SWITCHES SHALL HAVE REJECTION CLIP. ALL FUSES SHALL BE CURRENT LIMITING, CLASS "RK -5 ". ALL WIRING SHALL BE TYPE THHN /THWN, CU CONDUCTORS, U.O.N.. ALL DEVICES SHALL BE LISTED BY U.L. OR ANY APPROVED TESTING LAB FOR INTENDED USE. ALL FEEDER LENGTHS ARE SHOWN FOR VOLTAGE DROP CALC'S ONLY. ALL DEVICES SPECIFIED ARE SQUARE D PRODUCTS. LOAD SUMMARY (E) VAI\ SWITCHBOARD 277/480 V, 30, 4W 4 1 DESIGN LOAD ( 0100%) 100A NEW TOTAL CONNECTED LOAD (PANEL "LA ", INCLUDING SPARE & L.C.L. LOADS) - 62A N.T.S. Doi.-1,11k RECEIVED 4. CITY OF Tt JAN 22 - 3 t-'zh6dpi 1 i La ' i/ UIQ� • • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415- 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489-5478 THESE PLANS AND SPEOFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS NOR ANY PORTION OF THEM' WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHBITED. REV DATE DESCRIPTION 10112/07 DD SET 12/07/07 CD SET 01/09/08 PCC SET Cr) 4t H z U w gcl 0 06 a) co N C!) z 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: SINGLE LINE DIAGRAM E-.2 FIXTURE SCHEDULE SYMBOL & TYPE DESCRIPTION MOUNT VOLT. LAMP TOTAL V.A. NOTE - N O T Y P E TYPE DA 0 PENDENT MOUNT FLUOR. FIXTURE RESOLUTE # 5100 SERIES PEND. 120 1 26W PL 26 FINISH: PROGENY BLONDE DB Q WALL SCONCE MURRAY FEISS LTG. # WB1218BRB SURFACE 3 25 W INC. 75 FINISH: BLANCHED PATINA DC 0 CHANDELIER ELK LIGHTING, ROCOCO SERIES # ELK 2717 -8 -1 -120 CHAIN HUNG 9 60W 540 FB r __, 10) 1 Lk �J CALCULITE HID ADJUSTABLE ACCENT LT. LIGHTOLIER # C4T4A- CCDP- MHT4RNF- C4A39T4E1 REC. 1 39 MH 44 FB1 1 10'1 L'%1 CALCULITE HID ADJUSTABLE ACCENT LT LIGHTOLIER # C4T4A- CCDP- MHT4RF- C4A39T4E1 REC. 1 39 MH 4.5 44 FC 0 CALCULITE COMPACT FLUORESCENT LT. LIGHTOLIER # 8021 CCDP- S6132BU REC. 1 26W PL 26 FF Q RECESSED FLUORESCENT WALL WASHER LIGHTOLIER # 315STX- 302MRIC9X REC. 1 37W MR16 37 FG I--- -- 0--- --1 4' OPEN STRIP FLUORESCENT FIXTURE BARTCO LIGHTING # BFL800 -1T/32 -120 SURFACE 1 25W T8 25 FN I - -0 - --1 4' OPEN STRIP FLUORESCENT FIXTURE LIGHTOLIER # CL- 1 -4 -E81 -120 SURFACE 1 28W T8 28 J ® BASIC BATH STRIP ARTEMIDE # RZK- BASICBTH SURFACE 1 17W T8 17 CENTER ABOVE MIRROR M LOW- PROFILE WRAPAROUND LITHONIA LIGHTING # LB -2 -32- 120 -GEB SURFACE 2 32W T8 62 0 EM EMERGENCY LIGHTING McPHILBEN # CAX6 SURFACE 1 2 6W MR16 HALOGEN 12 USE BATTERY UNIT MINIMUM OF 90 MIN. X 0 RENAISSANCE SERIES MULE LIGHTING # CEL -B SURFACE 1 LED 4 USE BATTERY UNIT MINIMUM OF 90 MIN. I c) d) e) f) 9) h) H r 1 2 r SPECIFIC NOTES DOOR BELL SPEAKER. RUN 1 /2 "C.O. WITH PULL WIRE TO P.A. SYSTEM UNIT LOCATION. VERIFY AT THE SITE. SALES AREA LIGHTING CONTROL SWITCH BANK. VERIFY EXACT LOCATION WITH ARCHITECT. LIGHTING NOTES a) ALL LIGHT FIXTURES SHALL BE BARE ESCENTUALS STANDARDS AND BE FURNISHED AND INSTALLED BY THE CONTRACTOR, U.O.N. PROVIDE FIXTURE SUBMITTAL FOR APPROVAL PRIOR TO PLACING THE ORDER. b) VERIFY TYPE OF CEILING, MOUNTING DETAILS, REQUIRED HANGERS & FASTENERS, TRIMS AND VOLTAGE PRIOR TO PLACING THE ORDER. ALL RECESSED DDWNLIGHTS TO BE THERMALLY PROTECTED PER N.E.C. & U.L. REQUIREMENTS . USE ENERGY EFFICIENT FLUOR. LAMPS, (T8, PL, ETC.) & ELECTRONIC BALLAST FOR ALL FLUORESCENT LIGHT FIXTURES. VERIFY EXACT LOCATION OF ALL LIGHT FIXTURES & MOUNTING HEIGHTS PRIOR TO ANY WORK. INSTALL SWITCHES & DIMMERS IN A GANG BOX UNDER COMMON COVERPLATE, WHERE APPLICABLE. ALL LIGHT FIXTURES USED IN THE PROJECT SHALL BE LISTED FOR INTENDED USE. EXIT SIGNS: REVIEW BUILDING DEPARTMENT APPROVED ARCHITECTURAL REFLECTED CEILING PLAN FOR ANY REVISIONS ON REQUIRED QUANTITY, FACES, DIRECTIONAL ARROWS PRIOR TO PLACING THE ORDER. PROVIDE ASTRONOMICAL TIME CLOCK FOR LIGHTING CONTROL PER BARE ESSENTUAL REQUIREMENTS. "NL" INDICATES 24 HR. UNSWITCHED NIGHT LIGHT WITH EMERGENCY BATTERY PACK UNIT. BATTERY SHALL HAVE MINIMUM OF 90 MINUTES OPERATION CAPACITY AT FULL LOAD. PROVIDE ALL REQUIRED MOUNTING HARDWARE FOR CHANDELIER PER MANUFACTURER'S RECOMMENDATIONS. STORE FRONT, SHOW WINDOW & SIGN SHALL BE CONTROLLED BY TIME CLOCK & BE "ON" FROM DUSK TO 12:00 AM n) ALL J —BOX'S SHOULD BE PLACED AT THE HEIGHT OF 8' —O". LA -19 SWITCH BANK 2 LIGHTING PLAN LA -9,11 (VIA SW g,h) SCALE: 1/4"=1-0" LA-1,3-5,7 (VIA SW a,b,c,d,e) TYPICAL 1 e N FC H.C. UNISEX RESTROOM 1�Cl, n " MA — n n / c1 �y +, % %/% //%%%/ / % // // / / / /// // // ////// // // / / / /I/ . — STOCKROOM LA -17 7e _5c SALES 7e 5c e ILA ,I 7NL\ i r ''1 y O .(0) 1 /OH- 7e 13m - 1 - )O4&.5 LA -13 (VIA SW j,k,m) r" ' RECEIVED Y1; CITY OF TUKWILA DEC 1 9 2007 EHMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX 415 - 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS. AS WELL AS BARE ESCENTUALS NAME AM) LOGO, TRADEMARKS AND DESIGNS ARE TIE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIRCATION, DISCLOSURE AND /DR USE DF THESE MATERIALS (OR ANY PORTION OF THEM WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBREO. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET I4 . 4 - E• c ,.% 0 Z � 0 °' 00 (f) ; 0 a) 2 W - - 5 ' A-1 O -- w a) r 4t4 W a f 0 0, oS a) a) z 0 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: LIGHTING PLAN E -3 - B Lsrl r W I) al 30 it - FIG FIG 1 •� '� c) d) e) f) 9) h) H r 1 2 r SPECIFIC NOTES DOOR BELL SPEAKER. RUN 1 /2 "C.O. WITH PULL WIRE TO P.A. SYSTEM UNIT LOCATION. VERIFY AT THE SITE. SALES AREA LIGHTING CONTROL SWITCH BANK. VERIFY EXACT LOCATION WITH ARCHITECT. LIGHTING NOTES a) ALL LIGHT FIXTURES SHALL BE BARE ESCENTUALS STANDARDS AND BE FURNISHED AND INSTALLED BY THE CONTRACTOR, U.O.N. PROVIDE FIXTURE SUBMITTAL FOR APPROVAL PRIOR TO PLACING THE ORDER. b) VERIFY TYPE OF CEILING, MOUNTING DETAILS, REQUIRED HANGERS & FASTENERS, TRIMS AND VOLTAGE PRIOR TO PLACING THE ORDER. ALL RECESSED DDWNLIGHTS TO BE THERMALLY PROTECTED PER N.E.C. & U.L. REQUIREMENTS . USE ENERGY EFFICIENT FLUOR. LAMPS, (T8, PL, ETC.) & ELECTRONIC BALLAST FOR ALL FLUORESCENT LIGHT FIXTURES. VERIFY EXACT LOCATION OF ALL LIGHT FIXTURES & MOUNTING HEIGHTS PRIOR TO ANY WORK. INSTALL SWITCHES & DIMMERS IN A GANG BOX UNDER COMMON COVERPLATE, WHERE APPLICABLE. ALL LIGHT FIXTURES USED IN THE PROJECT SHALL BE LISTED FOR INTENDED USE. EXIT SIGNS: REVIEW BUILDING DEPARTMENT APPROVED ARCHITECTURAL REFLECTED CEILING PLAN FOR ANY REVISIONS ON REQUIRED QUANTITY, FACES, DIRECTIONAL ARROWS PRIOR TO PLACING THE ORDER. PROVIDE ASTRONOMICAL TIME CLOCK FOR LIGHTING CONTROL PER BARE ESSENTUAL REQUIREMENTS. "NL" INDICATES 24 HR. UNSWITCHED NIGHT LIGHT WITH EMERGENCY BATTERY PACK UNIT. BATTERY SHALL HAVE MINIMUM OF 90 MINUTES OPERATION CAPACITY AT FULL LOAD. PROVIDE ALL REQUIRED MOUNTING HARDWARE FOR CHANDELIER PER MANUFACTURER'S RECOMMENDATIONS. STORE FRONT, SHOW WINDOW & SIGN SHALL BE CONTROLLED BY TIME CLOCK & BE "ON" FROM DUSK TO 12:00 AM n) ALL J —BOX'S SHOULD BE PLACED AT THE HEIGHT OF 8' —O". LA -19 SWITCH BANK 2 LIGHTING PLAN LA -9,11 (VIA SW g,h) SCALE: 1/4"=1-0" LA-1,3-5,7 (VIA SW a,b,c,d,e) TYPICAL 1 e N FC H.C. UNISEX RESTROOM 1�Cl, n " MA — n n / c1 �y +, % %/% //%%%/ / % // // / / / /// // // ////// // // / / / /I/ . — STOCKROOM LA -17 7e _5c SALES 7e 5c e ILA ,I 7NL\ i r ''1 y O .(0) 1 /OH- 7e 13m - 1 - )O4&.5 LA -13 (VIA SW j,k,m) r" ' RECEIVED Y1; CITY OF TUKWILA DEC 1 9 2007 EHMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX 415 - 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS. AS WELL AS BARE ESCENTUALS NAME AM) LOGO, TRADEMARKS AND DESIGNS ARE TIE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIRCATION, DISCLOSURE AND /DR USE DF THESE MATERIALS (OR ANY PORTION OF THEM WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBREO. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET I4 . 4 - E• c ,.% 0 Z � 0 °' 00 (f) ; 0 a) 2 W - - 5 ' A-1 O -- w a) r 4t4 W a f 0 0, oS a) a) z 0 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: LIGHTING PLAN E -3 '� '•111 •� '� '�rl� •� c) d) e) f) 9) h) H r 1 2 r SPECIFIC NOTES DOOR BELL SPEAKER. RUN 1 /2 "C.O. WITH PULL WIRE TO P.A. SYSTEM UNIT LOCATION. VERIFY AT THE SITE. SALES AREA LIGHTING CONTROL SWITCH BANK. VERIFY EXACT LOCATION WITH ARCHITECT. LIGHTING NOTES a) ALL LIGHT FIXTURES SHALL BE BARE ESCENTUALS STANDARDS AND BE FURNISHED AND INSTALLED BY THE CONTRACTOR, U.O.N. PROVIDE FIXTURE SUBMITTAL FOR APPROVAL PRIOR TO PLACING THE ORDER. b) VERIFY TYPE OF CEILING, MOUNTING DETAILS, REQUIRED HANGERS & FASTENERS, TRIMS AND VOLTAGE PRIOR TO PLACING THE ORDER. ALL RECESSED DDWNLIGHTS TO BE THERMALLY PROTECTED PER N.E.C. & U.L. REQUIREMENTS . USE ENERGY EFFICIENT FLUOR. LAMPS, (T8, PL, ETC.) & ELECTRONIC BALLAST FOR ALL FLUORESCENT LIGHT FIXTURES. VERIFY EXACT LOCATION OF ALL LIGHT FIXTURES & MOUNTING HEIGHTS PRIOR TO ANY WORK. INSTALL SWITCHES & DIMMERS IN A GANG BOX UNDER COMMON COVERPLATE, WHERE APPLICABLE. ALL LIGHT FIXTURES USED IN THE PROJECT SHALL BE LISTED FOR INTENDED USE. EXIT SIGNS: REVIEW BUILDING DEPARTMENT APPROVED ARCHITECTURAL REFLECTED CEILING PLAN FOR ANY REVISIONS ON REQUIRED QUANTITY, FACES, DIRECTIONAL ARROWS PRIOR TO PLACING THE ORDER. PROVIDE ASTRONOMICAL TIME CLOCK FOR LIGHTING CONTROL PER BARE ESSENTUAL REQUIREMENTS. "NL" INDICATES 24 HR. UNSWITCHED NIGHT LIGHT WITH EMERGENCY BATTERY PACK UNIT. BATTERY SHALL HAVE MINIMUM OF 90 MINUTES OPERATION CAPACITY AT FULL LOAD. PROVIDE ALL REQUIRED MOUNTING HARDWARE FOR CHANDELIER PER MANUFACTURER'S RECOMMENDATIONS. STORE FRONT, SHOW WINDOW & SIGN SHALL BE CONTROLLED BY TIME CLOCK & BE "ON" FROM DUSK TO 12:00 AM n) ALL J —BOX'S SHOULD BE PLACED AT THE HEIGHT OF 8' —O". LA -19 SWITCH BANK 2 LIGHTING PLAN LA -9,11 (VIA SW g,h) SCALE: 1/4"=1-0" LA-1,3-5,7 (VIA SW a,b,c,d,e) TYPICAL 1 e N FC H.C. UNISEX RESTROOM 1�Cl, n " MA — n n / c1 �y +, % %/% //%%%/ / % // // / / / /// // // ////// // // / / / /I/ . — STOCKROOM LA -17 7e _5c SALES 7e 5c e ILA ,I 7NL\ i r ''1 y O .(0) 1 /OH- 7e 13m - 1 - )O4&.5 LA -13 (VIA SW j,k,m) r" ' RECEIVED Y1; CITY OF TUKWILA DEC 1 9 2007 EHMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX 415 - 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS. AS WELL AS BARE ESCENTUALS NAME AM) LOGO, TRADEMARKS AND DESIGNS ARE TIE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIRCATION, DISCLOSURE AND /DR USE DF THESE MATERIALS (OR ANY PORTION OF THEM WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBREO. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET I4 . 4 - E• c ,.% 0 Z � 0 °' 00 (f) ; 0 a) 2 W - - 5 ' A-1 O -- w a) r 4t4 W a f 0 0, oS a) a) z 0 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: LIGHTING PLAN E -3 H r I LT 1 T I L I SPECIFIC NOTES 1 2 3 4 5 6 7 8 J 9 STOCKROOM I S 31 .. • .C. UN RES RsM _ I'� ID � 1 1 i �// // %4444 // // !/// 4/ /41,11/ /4 4444// /I GUTTER (SEE E -2) LA -20 LA-1 6,18 POWER PLAN LA -31,33 LA -27 LA -14 0 SCALE: 1/4"= TELEPHONE BACKBOARD. SEE SHEET E-5. 460V MAIN DISCONNECT SWITCH. SEE DWG. E-2 SINGLE LINE DIAGRAM. FOR CONNECTION TO SIGN. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SIGN CONTRACTOR. PROVIDE 120V, 20A, 1P DISCONNECT SWITCH MOUNT NEXT TO J-BOX AS RERQUIRED. FOR CONNECTION TO INSTA -HOT WATER HEATER. VERIFY EXACT LOCATION WITH PLUMBING CONTRACTOR. PROVIDE 240V, 20A, 2P DISCONNECT SWITCH AS RERQUIRED. PROVIDE 120V, 20A CEILING MOUNTED SHOW WINDOW RECEPTACLE. VERIFY EXACT LOCATION AT THE SITE. PROVIDE 120V, 20A CEILING MOUNTED RECEPTACLE FOR INSTALLATION OF FUTURE SECURITY DEVICE. VERIFY EXACT LOCATION WITH SECURITY SYSTEM CONTRACTOR. VERIFY EXACT LOCATION OF 120V, 20A PLASMA TV DUPLEX RECEPTACLE. AND AUDIO VISUAL OUTLETS WITH ARCHITECT. VERIFY ALL REQUIREMENTS WITH COMMUNICATION CONTRACTOR PRIOR TO ANY WORK. FOR CONNECTION TO DOOR HOLD OPEN AT ENTRY. VERIFY ALL REQUIREMENTS PRIOR TO INSTALLATION OF OUTLET. WP J -BOX FOR CONNECTION TO REMOTE WATER METER. VERIFY EXACT LOCATIO AND REQUIREMENTS WITH PLUMBING CONTRACTOR. O 27 31 (E) SERVICE CORRIDOR SALES 27 27 31 GENERAL NOTES LA- 21,23,25 31 LA -8 Y 7 A- VERIFY EXACT LOCATION OF ALL OUTLETS WITH BARE ESSENTUAL SITE CONSTRUCTION MANAGER PRIOR TO ANY WORK. ALL DEVICES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES, ETC. SHALL BE NEW AND U.L. LISTED FOR INTENDED USE. STAGGER ALL BACK -TO -BACK OUTLETS (1) STUD SPACE . D- ANY CIRCUIT FEEDING ONLY ONE RECEPTACLE SHALL HAVE 120V, 20A DUPLEX RECEPTACLE, U.O.N. B- C- E- ALL POWER, TELE /DATA, TV OR OTHER OUTLETS SHOWN SIDE -BY -SIDE, SHALL BE MOUNTED A 1 1/2" SEPARATION, (OR A STUD WIDTH), BETWEEN THE BOXES. (FLOOR OUTLETS SIMILAR). MOUNT ALL OUTLETS AT +18" A.F.F., U.O.N. F- COLOR OF RECEPTACLES, SWITCHES & COVERPLATES SHALL BE WHITE. U.O.N. G- PROVIDE GROUND WIRE WITH ALL HOMERUNS & BRANCH WIRING. H- K- FIRE ALARM SYSTEM: ALTERATIONS TO FIRE-LIFE SAFETY SYSTEM SHALL BE DONE BY A LANDLORD APPROVED VENDOR UNDER THIS CONTRACT. THE FIRE ALARM CONTRACTOR SHALL PROVIDE DETAILED DRAWINGS SHOWING ALL REQUIRED DEVICES (SUCH AS PULL STATION, STROBE, HORN, SMOKE DETECTOR, DUCT DETECTOR, SPEAKER, MAGNETIC HOLD OPENS, TRANSPONDER, ETC), AND THEIR CONNECTION TO EXISTING SYSTEM AND OBTAIN APPROVAL FROM BUILDING DEPARTMENT PRIOR TO ANY WORK. ALL NEW CONNECTIONS TO EXISTING SYSTEM SHALL BE PER NFPA 72 AND MEET LOCAL FIRE MARSHAL REQUIREMENTS. VERIFY ALL PRIOR TO INSTALLATION OF DEVICES. I- INFORMATION GIVEN ON THE DRAWINGS REGARDING EXISTING INSTALLATIONS OR CONDITIONS HAS BEEN OBTAINED FROM THE BEST SOURCES AVAILABLE, BUT CAN NOT BE GUARANTEED ACCURATE IN ALL RESPECTS. VERIFY ALL SUCH INFORMATION BEFORE PROCEEDING WITH ANY NEW WORK THAT MAY BE AFFECTED. INCLUDE AS A PART OF THE CONTRACT ALL WORK REQUIRED TO PRODUCE THE INDICATED RESULT. J- RELOCATE AND /OR RECONNECT EXISTING CIRCUITS WHERE CONTINUITY HAS BEEN AFFECTED OR AS MAY BE REQUIRED TO PROVIDE FOR NEW CONSTRUCTION. PROVIDE CONDUIT FOR THERMOSTAT, VAV BOX AND DUCT DETECTORS AS REQUIRED. RECEIVE CITY ror i R D :A, = JAN 2 2 3 I (..f,7.a et' e • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415- 362 -5857 FX 415 -362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIRCATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS MR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 PCC SET z U A L 0 0 �� a VJ W 4t4 U 0:1 C 0 C) 0) a) N z 0 PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: POWER PLAN 110 E -4 NUMBER USE USE TBD VOICE LINE 1 MANAGER'S DESK TBD ROLLOVER VOICE 2 MANAGER'S DESK TBD MODEM 1 T.T.B. CASHWRAP, POS # 1, 2 & 3 TBD MODEM 2 T.T.B. TBD FAX T.T.B. & CASHWRAP WALL MOUNTED DEMARC 110 PUNCH DOWN BLOCK. (LABLE EACH CONNECTION) WALL MOUNTED DATA 24 PORT PATCH PANEL. ( LABLE EACH CONNECTION) 1"C. TO LANDLORD C TELEPHONE CLOSET CONFIRM EXACT LOCATION OF SERVER EQUIP. WITH ARCHIT. PRIOR TO ROUGH -IN LOCATE WITHIN MILLWORK COORD. EXACT LOCATION W/ ARCHITECTURAL ELEVATIONS AND MILLWORK CONTRACTOR PRIOR TO ROUGH-IN. SIGNAL PLAN I I I I I I I I I O M N.T.S. TELEPHONE BACKBOARD 4'X4'X3/4" THICK FIRE RATED PLYWOOD TO TELE /DATA JACKS (CASH WRAP, ETC.) 4 --PLEX / 7 RECEPTACLE TELEPHONE BACKBOARD (T.T.B.) DETAIL SALES SCALE: 1/4"=1"-0" _ = N STOCKROOM H.C. UNISEX RESTROOM / / / /// /! /! / / / /!! !/ !/ /// /// // // / / /III !! /! / / / /// .� n n II II El II r,∎ 1M, am �wo CABLE DROP ONLY. LOCATED ABOVE CEILING AV (1) 1 CONTACT: DEBORAH TAYLOR © 415 489 - 5539 IF YOU HAVE ANY QUESTIONS REGARDING THIS DATA PLAN DATA JACK SPECIFICATIONS: 1. T.T.B. - NETWORK PATCH PANEL (36" FROM FLOOR ON WALL ABOVE "BELKIN BOX" - BIG BLACK BOX DELIVERED TO STORE ADDRESSED TO DEBORAH) 2. CASHWRAP - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 3. POS # 1 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 4. POS # 2 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 5. POS # 3 - (2) LIVE DATA JACKS (LINKED BACK TO PATCH PANEL # 1). 6. DEVICE ABOVE ENTERY - (2) LIVE DATA JACKS 7. MANAGER'S DESK - (1) LIVE DATA JACKS AND (1) ANALOG JACK FOR FAX LINE (TO DEMARC). TELECOMMUNICATIONS SPECIFICATIONS PURPOSE - THIS DOCUMENT ESTABLISHES THE STANDARDS AND DEFINES THE TECHINICAL SPECIFICATIONS FOR COMMUNICATION WIRING. CONTRACTORS - THIS DOCUMENT SETS THE MINIMUM COMPLIANCE REQUIREMENTS FOR CABLING INSTALLERS. WIRING SUBCOMPONENTS - THE FOLLOWING WIRING SUBCOMPONENTS ARE COVERED UNDER THIS DOCUMENT. HORIZONTAL CATEGORY 5 (UTP) CABLES RGB AND COAXIAL CABLES WORK STATION JACKS LABELING DESIGN STANDARDS - DESIGN STANDARD FOR TEH FOLLOWING AREAS: EXTENDED DEMARC (Taco MULTI PAIR FROM THE BUILDING MAIN POINT OF ENTRY (MPOE) TO THE EQUIPMENT ROOM) WALL MOUNTED EQUIPMENT LAYOUT. WIRING CONTRACTOR COMPLIANCE - ANY CONTRACTOR PERFORMING TELECOMMUNICATIONS WIRING WORK SHALL BE A CERTIFIED INSTAI I FR. THE CONTRACTOR SHALL HAVE AT LEAST ONE PERSON ON HIS /HER STAFF THAT IS BICSI RCDD CERTIFIED. ALL WIRING CONTRACTORS MUST AGREE TO COMPLY WITH ALL LOCAL, STATE, AND FEDERAL LAWS REGARDING BUILDING CODES, SAFETY CODES, ENVIROMENTAL CODES, NATIONAL ELECTRICAL CODE AND ANY OTHER APPLICABLE LAWS WITHIN THE JURISDICTION OF THE PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT ALL UTP CABLES APPLICABLE GOVERNING BODY FLAME RETARDANT SPECIFICATIONS. THE CONTRACTOR MUST BE UCENSED IN THE SUBJECT STATE INSTALLATION OF "LOW VOLTAGE WIRING INSTALLATIONS ", AS REQUIRED BY STATE LAWS AND REGULATIONS. ALL WIRING CONTRACTORS SHALL EXTEND A MINIMUM OF ONE (1) FULL YEAR PARTS AND LABOR WARRANTY ON THE TELECOMMUNICATIONS WIRING WORK PERFORMED. ANY TRAVEL COSTS ASSOCIATED WITH THE WARRANTY SHALL BE THE RESPONSIBLITY OF THE CONTRACTOR AND SHALL NOT BE BILLED BACK TO THE OWNER. DAMAGE TO PARTS AND EQUIPMENT RESULTING WARRANTY IS IN ADDITION TO THE STANDARD MULTI -YEAR WARRANTY PROVIDED UNDER THE UNIPRISE STRUCTURE WIRING SYSTEMS. THE CONTRACTOR MUST PROVIDE DOCUMENTATION IDENTIFYING WIRING INSTALLATIONS WARRANT( PROVISIONING FOR THE WARRANTY LIFE OF THE WIRING INSTALLATIONS. THIS DOCUMENTATION MUST SPECIFICALLY IDENTIFY WHO (SUBCONTRACTOR, UNIPRISE, ETC.) WILL SUPPORT THE WIRING INSTALLATIONS WARRANTY IN THE EVENT THAT THE CONTRACTOR SHOULD CEASE BUSINESS OPERATIONS DURING THE WARRANTY PERIOD THE DOCUMENTATION SHOULD PROVIDE DETAILS ON THE TYPE OF CABLE END -TO -END WARRANTY THAT IS BEING OFFERED, I.E. "CHANNEL UNK WARRANTY". FOR NEW INSTALLATIONS, THE CONTRACTOR MUST SUPPLY AS -BUILT DRAWINGS. THE CONTRACTOR MUST HAVE ALL LEGAL AGREEMENTS IN PLACE, INCLUDING BUT NOT UMF ED TO, STANDARD CONTRACTOR AGREEMENT, CONFIDENTIALITY AND NON- DISCLOSURE AGREEMENT, AND PROOF OF INSURANCE. CABLING STANDARD - A CERTIFIED CABLE SOLUTION CARRYING A MANUFACTURER'S WARRANTY IS TO BE INSTAI I FD. MANUFACTURE'S SPECIFICATIONS MEET ANSI /TIA /ETA 568 -B 2.1 STANDARDS. WIRING SUBCOMPONENTS - ALL HORIZONTAL CABLING SHOULD QUAUFY TO BE PART OF THE MANUFACTURER'S CERTIFIED SOLUTION. FROM THE SERVER ROOM. ALL HORIZONTAL CABUNG SHOULD BE ROUTED IN A MAIN BUNDLE AND ALWAYS MAKE 90 DEGREE TURNS (NO DIAGONAL ROUTES). THECABLING IS TO BE SUPPORTED SUFFICIENTLY TO MEET LOCAL CODES. ALL VOICE HORIZONTAL CABLING IS TO BE WHITE AND ALL DATA IS TO BE BLUE. LABEUNG - ALL WORKSTATION JACKS AND CABLES ARE TO BE LABELED WITH THE DESIGNATED OFFICE, ROOM OR CUBUCLE LOCATION NUMBER,. IN ADDITION, A,B IS TO BE USED FOR VOICE AND C,D FOR DATA, THESE SAME IDENTIFYING LABELS ARE TO BE USED ON THE ORIGINATING ENDS. (EX. OFFICE 101 WOULD HAVE 101 -A, 101 -B, 101 -C AND 101 -D) THESE LABELS SHOULD APPEAR ON THE PATCH PANEL, EACH END OF THE CABLE AND ON THE WORKSTATION JACK. CASHWRAPS - STANDARD CASHWRAP - 3 EACH, CAT 5 UTP CABLES TO EACH WORKSTATION (1 CABLE FOR VOICE AND 2 CABLES FOR DATA) SINGLE LINE WALL - TELEPHONE - 1 EACH, CAT 5 UTP WHITE CABLE TO EACH TELEPHONE JACK. THE FIRE RATING OF ALL CABLES MUST COMPLY WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL BUILDING CODE REQUIREMENTS. SINGLE STATION TELEPHONE JACKS WILL LITTUZE A SINGLE RJ -45 JACK TO TERMINATE THE 4 PAIR CAT. 5 CABLE. ALL FOUR PAIRS OF THE CABLE MUST BE TERMINATED ON THE STATION JACK IN ORDER TO MAINTAIN THE ANSI/TIA /EIA- 568 -B STANDARD. DESIGN STANDARDS - EXTENDED DEMARC THE EXTENDED DEMARC SHOULD BE A MINIMUM OF 50 PAIR, MEETING LOCAL BUILDING CODES FOR FIRE SAFELY. THE CABLE SHOULD ORIGINATE ON A 66 BLOCK IN THE BUILDING MPOE AND TERMINATE ON A 110 STYLE BLOCK IN THE TELEPHONE BACKBOARD. SPECIFIC NOTES — SIGNAL 171 PROVIDE 1 "C. WFTH ONE CAT. 5 BACK TO PATCH PANEL AT T.T.B. STUB CONDUIT TO ABOVE CLG. NEAR CENTER DOORWAY AND LEAVE 10' CABLE SERVICE LOOP FOR FUTURE TRAFFIC COUNTER. 2 4' X 4' X 3/4" THICK FIRE RETARDANT PLYWOOD TELE. BACKBOARD. PAINT TO MATCH ADJACENT FINISH. RUN 1"C. TELEPHONE WITH PULL STRING TO EXISTING BUILDING TELEPHONE BACKBOARD. VERIFY REQUIRED CONDUIT SIZE WITH COMMUNICATION CONTRACTOR. PROVIDE 3/4 "C, 1#6 CND., CONNECT TO BLDG. GND., STEEL STRUCTURE AND BOND TO MAIN C.W. PIPE. I-31 1 PROVIDE TV OUTLET WITH COAX CABLING FOR PLASMA TV UNIT (IN NICHE) BACK TO TELEPHONE BACKBOARD. COORDINATE LOCATION AND WIRING REQUIREMENTS PER OWNER'S /ARCHITECT'S VENDOR. 4 5 6 7 PROVIDE 1"C. FOR TELE. /DATA CABLING WITH THREE CAT. 5 CABLES AND ROUTE BACK TO PATCH PANEL. STORE USES 2 LINE PHONES- ONE CORDDED PHONE IN THE BACK OFFICE AND ONE REMOTE UNIT. -MAIN VOICE LINE AND ROLLOVER LINE NEEDS TO BE TERMINATED ON "2 LINE JACK" AT THIS LOCATION. - REMOTE EXTENSION UNIT AT CASH WRAP (NO JACK NEEDED). USE "66" TYPE BLOCK PANEL FOR ALL PHONE TERMINATIONS AT MAIN DEMARC AT THIS LOCATION. RECEIVED USE '12 PORT NETWORK PATCH PANEL FOR ALL DATA /VOICE TERMINATIONS AT THIS LOCATIOPI' OF TUKVVILA NOT WALL PLATES. DEC 19 2007 PEHMIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415 -362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPE0RCATIONS. AS WELL AS BARE ESCENTUALS NAME AI11 LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIRCATION, DISCLOSURE AMC /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM( WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 4c4 z U d fJ `+) • › co co oo (6 QO O 0- 00 C J a) a a) 0 0 co co co cd • C 0 0 oes c) a) a) z 0 PROD. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: , : zSIGNAL PLAN E -5 f Lr 1 EF HVAC PLAN SCALE: 1/2" = 1' -0" ',/ STOCKRO /, M H.C. UNIS RESTRO 6'0 6X6 C 50 CF SD -3 8X8 CD 100 CFM SD -2 6 24 24 8X8 CC 100 CFM SD -2 10 "0 %-;/// /7/ //%r „vim i / /// ///// /// //2% / / /i; I. L 01 SD -1 _ Q - 250 EFM L - f IIO I II .1 \ - I I r - ,7 O'I a I [ 0 I r ,1 I O I L .J /.- / / „ / //. // 4) 0 1/// 1 0 ” 0 r, r , I 1I0 1 1 (oII L I SALES 1O"0 250 o ( 0 1 L_ -'J L IV a SD -1 - Vf250 CFI - o 1 I _: -J OI • 1 4X24 r , r _ J 1 -1 I • pl1 pl1 `- yy,, pi 1 p11 1 Q11 _ - J SD-1 L ,1 L� . -- C'�L1 I 250 CFM € _& 0 .CI 250 CFM L O Q Q \ L ` -O I 1 50 /OIl L . 'J _C_ . _42. - - - - -_- . __. ¢] - - - - 250 16 KEY NOTES O NEW DOUBLE DUCT SIZE 12 MIXING BOX TO REMAIN • MECHANICAL CONTRACTOR SHALL PROVIDE THERMOSTAT AS INDICATED ON PLANS AT 5 FT. ABOVE FINISHED FLOOR. 0 NEW EXH. FAN RUN 6 ” ' EXHAUST DUCT TO EXISTING EXHAUST DUCT. 4 IF REQUIRED, PROVIDE DUCT SMOKE DETECTOR. DUCT SMOKE DETECTOR TO SHUT DN. THE BOX UPON ACTIVATION. PROVIDE AUDOI /VISUAL DEVICE, LOCATED IN CEILING FOR DUCT SMOKE DETECTOR. 0 INSTALL 1" INTERNALLY LINED SUPPLY DUCT AS SHOWN. RETURN AIR CEILING PLENUM. GENERAL NOTES FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. RECEIVED R, CITY OF TUKWILA DEC 1 9 2007 PEHI/IIT CENTER • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 -362 -5857 FX:415- 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THEE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARK5 AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS IDR ANY PORTION OF THEMI WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DO SET 12/07/07 CD SET 4t 1:4 > co co CO I _ co CO CO L T I- 0 5 CQ CO CO I- PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: HVAC PLAN Ris M -1 H.V.A.C. LEGEND SYMBOL ABBREV, DESCRIPTI ❑N MANUFACTURER AND MODEL B,D,D, BACK DRAFT DAMPER WEIGHT LBS M,BH THOUSAND BTUH S.P. IN.W.G. DUCT SECTION (SUPPLY) ICI 0 1 -1 0 VOLTS DUCT SECTI ❑N (RETURN) HZ DUCT SECTI ❑N (EXHAUST) I r - mil 0 CEILING COOK GEM -240 C,D. CEILING DIFFUSER 1- 1�1 -). r 4--^ R,A,R. RETURN AIR REGISTER 4-N- E.G./ E.R. EXAUST GRILLE/ REGISTER A -C L.D. LINEAR DIFFUSER TITUS M.C,A, MAX, CIRCUIT AMPACITY SEE DWG. T.S.P. TOTAL STATIC PRESSURE 1 F.L.A. FULL LOAD AMP ' M.V.D. MANUAL VOLUME DAMPER BORDER TYPE/ HARD OR LAY -IN SEE DWG. A.F.D. AUTOMATIC FIRE DAMPER - B A.V.D. AUTOMATIC VOLUME DAMPER Yi A,D, ACCESS DOOR O STAT ROOM THERMOSTAT Q B REMOTE TEMP. SENSOR o f U.C. UNDER -CUT c . -cws- C,W,S. COND. WATER SUPPLY - CWR -- C. V.R. COND. WATER RETURN -Hws- H.W.S. HOT WATER SUPPLY WA- H.W.R. HOT WATER RETURN - CHVS- CH.W.S, CHILLED WATER SUPPLY - C:HWR- CH.W.R. CHILLED WATER RETURN DIRECTI ❑N OF FLOW --> - X - G.V. GATE VALVE Coo G,LV, GLOBE VALVE -N- C.V. CHECK VALVE - Irl - B,V, BUTTERFLY VALVE A.P. ACCESS PANEL S.A. SUPPLY AIR R,A, RETURN AIR EA. EXHAUST AIR U.T.R. UP THRU ROOF ❑,S,A, OUTSIDE AIR DN, DOWN CLG. CEILING N.C. NORMALLY CLOSED N,O, NORMALLY OPEN N.I.C. NOT IN CONTRACT P,O,C, POINT OF CONNECTION G.C. GENERAL CONTRACTOR P.C. PLUMBING CONTRACTOR E,C, ELECTRICAL CONTRACTOR O FURN. & INST. BY ELEC. 0 FURN. & INST. BY MECH, EXHAUST FAN SCHEDULE SYMBOL SERVICE LOCATION MANUFACTURER AND MODEL FAN DATA MOTOR DATA WEIGHT LBS NOTES/ ACCESS. CFM S.P. IN.W.G. R.P.M. DRIVE HP WATT VOLTS PHASE HZ AIM BATHROOM CEILING COOK GEM -240 100 0.125 - DIRECT 60 120 1 60 15 A -C w AIR SUPPLY TITUS MCD BORDER TYPE/ HARD OR LAY -IN SEE DWG. - WHITE 1 B RG - 1 AIR RETURN TITUS 50 -F BORDER TYPE/ HARD OR LAY -IN GRILLE, REGISTER, A \D DIFFUSER SCHEDULE TAG SERVICE MAKE MODEL TYPE NECK SIZE & CFM FACE SIZE (L "XW ") FINISH FRAM TYPE NOTES/ ACCESS. SD -1 AIR SUPPLY TITUS FL15 BORDER TYPE/ HARD OR LAY -IN SEE DWG 4',,-0", 1 SLOT/ 2 SLOT WIDE STANDARD 1 A SD - 2 AIR SUPPLY TITUS TMS BORDER TYPE/ HARD OR LAY -IN SEE DWG. 24" x 24" WHITE 1 B SD -3 AIR SUPPLY TITUS MCD BORDER TYPE/ HARD OR LAY -IN SEE DWG. - WHITE 1 B RG - 1 AIR RETURN TITUS 50 -F BORDER TYPE/ HARD OR LAY -IN SEE DWG. 24" x 24" WHITE 1 B RG -2 AIR RETURN TITUS 50 -F BORDER TYPE/ HARD OR LAY-IN SEE DWG. 24" x 12" WHITE 1 B VAV UNIT SCHEDULE TAG AUNT. NOMINAL CFM TYPE MAKE (Sc MODEL ELECTRICAL COOLING CAPACITY (BTU) HEATING CAPACITY (KW) SUPPLY AIR CFM ESP INCH MIN AIR CFM SEER OR EER LB5 VOLTS PHASE HZ MCA MOCP VAV - 1 1 2600 SINGLE DUCT KRUEGER LMHS N/A N/A N/A N/A N/A - - - - 1300 - - HANGER AND BRACE SCHEDULE TERMINAL BOX WEIGHT MAX. LOAD EACH HANGER HANGER STRAP SIZE DIAGONAL BRACE SIZE UP TO 100# 72 # /HANCER 1 1 /2 "x 18 GA. 1 1/2 1/2'x18 GA. CIT 101 TO 225# 160# /HANGER 1 1/2 "x 16 GA. 1 1/2°x1 1/2'x18 GA. DE DRAWING LIST M -1 MECHANICAL CEILING PLAN M -2 MECHANICAL NOTES AND SCHEDULES & DETAILS GENERAL NOTES: 1. CODES, RULES AND REGULATIONS- DESIGN OF SYSTEM A) ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH ALL APPLICABLE FEDERAL STATE, AND LOCAL LAWS, ORDINANCES AND CODES. B) WHEN THE DRAWINGS CALL FOR MATERIALS OR CONSTRUCTION OF A BETTER QUALITY OR LARGER SIZES THAN REQUIRED BY THE ABOVE MENTIONED CODES AND RULES, WORK SHALL BE AS SPECIFIED OR SHOWN RATHER THAN AS REQUIRED BY CODE. ALL ITEMS OR FEATURES OF THE MECHANICAL SYSTEMS REQUIRED BY CODE SHALL BE INCLUDED, EVEN THOUGH NOT SPECIFIED HEREIN. C) INSTALLATION OF THE SYSTEMS SHALL BE IN ACCORDANCE WITH THE ABOVE MENTIONED CODES AND REGULATIONS AND ALSO SHALL CONFORM TO GOOD, ACCEPTED MECHANICAL PRACTICES. 2. FLEXIBLE CONNECTIONS AT SUPPLY AND RETURN AIR OPENINGS OF ALL AIR CONDIDONING UNITS. 3. FLEXIBLE DUCTS TO BE GLASS -FLEX 5-0 ", MAXIMUM IN LENGTH, WHERE APPUCABLE 4. PLUMBING CONTRACTOR TO FURNISH & INSTALL ALL CONDENSATE PIPING, INCLUDING FINAL CONNECTIONS. 5. CEIUNG DIFFUSERS TO BE EQUAL TO TITUS SERIES FL15 LINEAR DIFFUSER & PDS W/ O.B.D. 6. RETURN AND EXHAUST REGIS ILRS TO BE EQUAL TO TITUS 50F. 7. COORDINATE EXACT LOCATION OF ALL AIR OUTLETS AND INLETS (DIFFUSERS AND REGISTERS) VOITH APPROPRIATE ARCHITECTURAL PLANS REFLECTED CEILING, ELEVATIONS,ETC.) COLOR AS DIRE( BY ARCHITECT. 8. PROVIDE DUCT UNING TO SUPPLY DUCT OF EACH AC UNIT FOR MINIMUM OF 10 FT. DUCT LINING TO BE EQUAL TO JOHNS - MANVILLE, 1" THICK x 1-1/2 PCF DENSITY DUCT LINER. DUCTWORK TO BE INCREASED IN EACH DIMENSION TO INCORPORATE THICKNESS OF LINING. 9. DUCT INSULATION TO CONFORM TO LOCAL ENERGY CONSERVATION STANDARD CODES. 10. WIRING DIAGRAM IS INTENDED TO INDICATE SEQUENCE OF CONTROL AND DOES NOT NECESSARILY SHOW ALL CONNECTIONS REQUIRED BY LOCAL CODES. 11. AUTOMATIC TEMPERATURE CONTROL DEVICE FOR REGULATION OF SPACE TEMPERATURE SHALL BE CAPABLE OF BEING SET FROM 55 TO 85F, AND HAVE THE ABIUTY TO OPERATE THE HEATING AND COOLING IN SEQUENCE. CONTROL SHALL BE ADJUSTABLE TO PROVIDE A RANGE OF UP TO 107 BETWEEN FULL HEATING AND FULL COOLING AND HAVE CAPABILITY OF TERMINATING ALL HEATING AT A TEMPERATURE NO MORE THAN 70'F, AND COOLING AT A TEMPERATURE NDT LESS THAN 787. TSTATS TO BE HONEYWELL T7300A PROGRAMMABLE COMMERCIAL TSTAT WITH APPROPRIATE Q7300 SUB -BASE. 12 ROOF MOUNTED EQUIPMENT SHALL BE LABELED AS TO THE SPACE IT SERVES. 13. APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE FASTENED IN PLACE. 14. PROVIDE SEISMIC BRACING FOR ALL MECHANICAL EQUIPMENT STRUCTURE MOUNTED, 400 LBS. OR HEAVIER. 15. A MAINTENANCE LABEL SHALL BE AFFIXED TO MECHANICAL EQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED FOR THE OWNERS USE. 16. CONCEALED BUILDING SPACES USED AS RETURN AIR PLENUMS SHALL BE OF NON - COMBUSTIBLE MATERIAL. 17. PROVIDE ACCESS PANEL FOR ALL CEILING MOUNTED EQUIPMENT & VOLUME DAMPERS. 18. TRANSVERSE JOINTS FOR ALL AIR SUPPLY DUCTS INSTALLED WHERE AIR LEAKAGE WOULD BE NON- BENEFICIAL TO THE OCCUPIED AREA, TEMPERATURE REQUIREMENTS SHALL BE SEA' FIT WITH APPROVED MASTIC OR TAPE. 19. PROVIDE GALVANIZED SHEET METAL DUCTS FABRICATED AND INSTALLED TO ASHRAE AND SMACNA STANDARDS OR THE REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION WHOSE STANDARDS ARE MORE STRINGENT. (UMC CHAPTER 6 OF 2003) 20. DUCTWORK CONSTRUCTION DETAILS: A METARIAL: GAL SHEET METAL GAGE 26 FOR UP TO 14 "0 & GAGE 24 FOR UP TO 23% DUCT. B. SUPPORT: UP TO 10 DUCT SAME GAGE AS GAL STEEL DUCT, 1" WIDE OR (NO. 18 GAGE GAL STEEL WIRE) ON 10 FT. CRNTERS, AND UP TO 40 ° o DUCT SAME GAGE AS GAL. SIELL DUCT, 1" WIDE OR (NO. 8 GAGE GAL. STEEL WIRE) TIED TO 1" GAL STEEL BAND AROUND DUCT ON 10 FT. CRNTERS. C. HANGER: UP TO 360 DUCT 1/4" ROUND ROD OR 1 X 1" X 1 /B" ANGLE. 20. PROVIDE FIRE DAMPER WHERE DUCT PENETRATES FIRE RATED CEILING OR WALL IF APPUCABLE, PER LOCAL BUILDING CODE, BE OF APPROVED CONSTRUCTION AND HAVE PERMANENT I.D. AND ACCESS. 21. DUCT SIZES SHOWN ARE NET SIZED REQUIRED. INCREASE SIZES FOR THE LINED DUCT AS REQUIRED. 22. THE PROJECT SHALL BE AIR BALANCED AND A COPY OF THE FINAL REPORT SHALL BE PRESENTED TO B.E. PROJECT MANAGER. 23. THE MECHANICAL CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND FEES. 24. MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND VERIFY EXISTING LOCATION OF ALL EQUIPMENT AND THEIR WORKING CONDITION PRIOR TO WORK. ANY DISCREPANCY SHALL BE REPORTED TO ARCHITECT. 25. GENERAL CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE ADEQUACY OF THE STRUCTURE TO SUPPORT THE EQUIPMENT SPECIFIED. 26. GENERAL CONTRACTOR TO PROVIDE WEATHERPROOF EQUIPMENT AT LOCATIONS AGREED UPON IN CONSULTATION WITH H.V.A.C. CONTRACTOR. 27. ALL ROOF PENLIIlA11ONS TO BE WEATHERPROOF. 28. EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM SHALL BE EQUIPPED WITH AN AUTOMATIC SHUT -OFF. THE SMOKE DETECTOR SHALL BE INSTALLED IN THE MAIN SUPPLY AIR DUCT DOWNSTREAM OF THE FILTERS OR THEY MAY BE INSTALLED IN EACH ROOM OR SPACE SERVED BY THE SUPPLY AIR DUCT. D=TECTORS SHALL ALSO BE INSTALLED IN THE MAIN RETURN DUCT IF REQ D. BY THE LOCAL CODE) AHEAD OF OSA INTAKE. SEE CO E FOR EXEMPTIONS AND LOCAL AUTHORITY FOR CODE INTERPRETATION, OR AS INDICATED ON PLAN, 29. AIR CONDITIONING CONTRACTOR TO REMOVE AND DISPOSE OF ALL EXISTING EQUIPMENT AND DUCTWORK THAT ARE NOT USED. NOTE /ACCESSORY DESIGNATION: A - PROVIDE BACKDRAFT DAMPER B - SAFETY DISC. SWITCH C - INTERLOCK WITH LIGHT SWITCHD NOTE /ACCESSORY DESIGNATION: A - FRAM TYPE 22, PROVIDE FBPI -20 INSULATED B - FRAM TYPE 3 HVAC SPECIFICATION GENERAL: General Provisions of the Contract including General and Supplementary Conditions and General Requirements apply to work of this section. SCOPE: The base bid includes furnishing all materials, labor, tools, and equipment and the performance of all work required to install a complete heating and air conditioning system as outlined herein. QUALITY ASSURANCE : Provide a complete installation in conformance with the following standards. AGA American Gas Association ASHRAE American Society of Heating, Refrigerating and Air Conditioning Engineers NFPA National Fire Protection Association SMACNA Sheet Metal and Air Conditioning Contractors National Association. Commonwealth of STATE Uniform Statewide Building Code Indiana Mechanical Code WORK IN EXISTING SPACES : General: Care shall be taken when working in existing spaces so as not to damage existing walls and ceilings where work is being performed. Ceilings: Where work is being performed above ceilings, and the architectural drawings do not indicate ceiling modifications by the general contractor, it shall be the responsibility of this contractor to remove and replace existing ceilings where work is being performed. In those instances, all repair and installation of new grid, ceiling panels, etc shall be the responsibility of this contractor. Match existing finishes. Walls & Floors: It shall be the responsibility of this contractor to patch existing walls and floors and match existing finishes where work is being removed or installed and patching is being performed, unless noted otherwise on the architectural drawings. TESTS AND ADJUSTMENTS : No ducts, piping, fixtures or equipment shall be concealed or covered until they have been inspected and approved by the Architect and the inspector who shall be notified by the contractor when the work is ready for inspection. Work shall be completely installed, tested and leak tight before inspection is required All tests shall be repeated to the satisfaction of those making the inspection. EXECUTION INSTALLATION OF METAL DUCTWORK General: Assemble and install ductwork in accordance with recognized industry practices which will achieve air -tight (5 % leakage for systems rated 3" and under, 1 % for systems rated over 3 ") and noiseless (no objectionable noise) systems, capable of performing each indicated service. Install each run with minimum number of joints. Align ductwork accurately at connections, within 1/8' misalignment tolerance and with internal surfaces smooth. Support ducts rigidly with suitable ties, braces, hangers and anchors of type which will hold ducts true -to -shape and to prevent buckling. Support vertical ducts at every floor. Sealing: Seal all longitudinal seams, S's and drives and all joints with mastic or cement. Install according to SMACNA standards. Balancing Dampers: The sheet metal contractor shall be fully responsible for installing balancing dampers in the ductwork, (whether shown on the drawing or not) in order to arrive at the intended air flow. The balancing sub- contractor shall provide direction and assistance in determining locations where dampers are required. Additional dampers, if required shall be installed at no additional cost to the owner. Wall Penetrations: Seal and pack around all ducts and piping sleeves which pass through walls that extend to bottom side of structure and rated walls. Field Fabrication: Complete fabrication of work at project as necessary to match shop - fabricated work and accommodate installation requirements. Routing: Locate ductwork runs, except as otherwise indicated, vertically and horizontally and avoid diagonal runs wherever possible. Run ductwork in shortest route which does not obstruct useable space or block access for servicing building and its equipment. Hold ducts close to walls, overhead construction, columns, and other structural and permanent enclosure elements of bulding. Limit clearance to 1/2" where furring is shown far enclosure or concealment of ducts, but allow for insulation thickness, if any. Where possible, locate insulated ductwork far 1" clearance outside of insulation. Wherever possible in finished and occupied spaces, conceal ductwork from view, by locating in mechanical shafts, hollow wall construction or above suspended ceilings. Do not encase horizontal runs in solid partitions, except as specifically shown. Coordinate layout with suspended ceiling and lighting layouts and similar finished work. Electrical Equipment Spaces: Do not route ductwork through transformer vaults and their electrical equipment spaces and enclosures. Penetrations: Where ducts pass through interior partitions and exterior walls, and are exposed to view, conceal space between construction opening and duct or duct insulation with sheet metal flanges of same gage as duct. Overlap opening on 4 sides by at least 1 -1/2 ° . Fasten to duct and substrate. Where ducts pass through fire -rated floors, walls, or partitions, provide fire dampers and firestopping between duct and substrate, in accordance with requirements of Division -7 Section "F Coordination: Coordinate duct installations with installation of accessories, dampers, coil frames, equipment, controls and other associated work of ductwork system. INSTALLATION OF DUCT LINER General: Install duct liner in accordance with SMACNA HVAC Duct Construction Standards. Size of ductwork shown on the drawings is free net area, outside dimension of ducts will need to be increased if lined duct is Store internally lined ductwork up off of the floor. Protect internally lined ductwork from water and dust. 'Butter the leading edge of all internal duct lining with the manufacturer's recommended adhesive. Inspect and repair all damaged lining prior to installation of ductwork. INSTALLATION OF FLEXIBLE DUCTS Maximum Length: For any duct run using flexible ductwork, do not exceed 5' - 0" extended length. Installation shall have smooth full radius turns down to diffuser. Installation not permitted above inaccessible ceilings. ACCESS PANELS • Furnish all access panels required for proper servicing of equipment. Provide access panels for all concealed valves, vents, controls and cleonout doors, and sprinkler devices required by NFPA. Provide frame as required for finish. Furnish panels to General Contractor. Exact locations to be approved by the Architect. Minimum size to be 12" x 12', units to be 16 gauge steel, locking device shall be screwdriver cam locks. HANGERS AND SUPPORTS • Support all piping, ductwork and equipment by hangers or brackets. Furnish structural steel members where required to support piping and equipment. No portion of piping or valves shall be supported by equipment. Ductwork - Support by means of hangers as follows: Duct Width Hanger Size and Type Max. Spacing 60 or less 1 (l12 gage) 8 61 to 90 3/8" dia. Rod 8 A pair of hangers shall be located at every transverse joint and elsewhere according to the table. SEQUENCE OF OPERATION : HVAC UNIT : During occupied hours, supply fan shall operate continuously, and the outside air damper shall be open to the minimum position. Condensing unit shall cycle to maintain the required temperature set point During unoccupied hours the outside air damper shall be closed and the supply fan and condensing unit shall maintain the space set point. A differential enthalpy controlled economizer shall activate whenever the outside air enthalpy is lower than the enthalpy control setting. Economizer dampers shall modulate to full open position, as required, to maintain discharge air temperature between 52 and 56 degrees fahrenheit When the space temperature set point is satisfied, the damper shall return to the minimum outside air position during occupied mode and close completely during unoccupied mode. Upon a signal from the duct smoke detectors or zone fire alarm system, units shall shut down and outside air damper shall close. Exhaust Fans Toilet Exhaust Fans (Manual) Exhaust fans shall be controlled by local manual switch furnished, installed and wired by electrical contractor. When activated, exhaust fan motor damper shall open and fan shall start (Indicated by EC on MESCH schedule) Specialty Controls CONTROL WIRING Low Voltage Thermostats Low voltage thermostats shall be furnished, installed and wired by the HVAC contractor. The electrical contractor shall provide 4" square x 1- " deep wall outlet boxes at 60" above finished floor (with single -gang rings) for all thermostats /sensors. The electrical contractor shall provide one 3/4 empty conduit from each thermostat /sensor location, turned out above accessible ceilings (in joist space ar against overhead slab /deck). The HVAC /Temperature Control Contractor shall provide all other necessary conduit, raceway and wiring related work Conduit shall be identified in ceiling cavity and shall be provided with sweep bends, bushings and dragline. Line Voltage Thermostats General Control Wiring Requirements and Installation Methods Except where specifically indicated otherwise above, the HVAC /Temperature Control Contractor shall provide all electrical work as required for all temperature control related wiring (i.e. conduit, raceway, outlet boxes, junction boxes, wiring, etc.) in accordance with Division 16 requirements. All conduit shall be 3/4" minimum. CONTROLS: Electrical contractor will provide power wiring. HVAC contractor shall provide all the low voltage wiring of HVAC units and controls, thermostats and controllers. Thermostat shall be by the manufacturer of the HVAC unit (heat /cool /auto /off) with night setback. Provide plastic protective cover for all thermostats. Replace controls on existing unit, adjust and calibrate controls. GUARANTEE The contractor shall provide a guarantee in written form stating that all work under this section shall be free of defective work, materials, or parts for a period of one year from the date of owner's final acceptance and shall repair, revise or replace at no cost to the owner any such defects occurring within the guarantee period. Contractor shall also state in written form that any items or occurrences arising during the guarantee period will be attended to in a timely manner and will in no case exceed four (4) working days from date of notification by owner. FOR ADDITIONAL MALL REQUIREMENTS, SEE MALL DESIGN AND CONSTRUCTION CRITERIA. PRESSURE INDEPENDANT WITH DIGITAL CONTROL PLENUM - INSULATED FOR SUPPLY EXHAUST -NOT INSULATED ACOUSTICAL LINING Do1.4 a J1, DUCT COLLAR CEILING FLEXIBLE DUCT (MAX. 5' -0 ".) LINEAR DIFFUSER CON \ECTION DETAIL NOT TO SCALE GALVANIZED STEEL HANCE STRAP- MIN. (4) PER MIXING BOX- SEE SCHEDULE FOR SIZE. FOLD STRAP FOR DOUBLE THICKNESS- TYPICAL FOR ALL HANGER STRAPS. NOT TO SCALE SECURE TO CONCRETE STRUCTURE WITH 3/8" DIA. REDHEAD- TYPICAL EACH HANGER, STRAP DR BRACE IAGONAL BRACE TYPICAL -SEE SCHEDULE FOR SIZE (2) EACH SIDE. AIR TERMINAL BOX MOUNTING DETAIL RECEIVED OF TUKWIL A C 1 9 2991 r =r[1V11T CENT r R Y • • • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415 - 362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AND SPECIFICATIONS, AS WELL AS BARE ESCENTUALS NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSNE PROPERTY OF BARE ESCENTUALS. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (DR ANY PORTION OF THEM) WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 0 a 4t4 4t PC1 z U CO (ti CO OO L Ca CO 0_ CO a) I. 0 C) PROJ. NO.: PM: JC: CHECKED: 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) SHEET TITLE: MECHANICAL NOTES, DETAILS & SCHEDULE 4 M-2 ISEX RES S OM STOCKR KEY NOTES H r L -_J PLUMBING FLOOR PLAN SCALE: 1/2" = 1' -0" WH -1 WATER RISER DIAGRAM SCALE: NONE f' - - -- - - - - -- - - - - - -- - - - - -- - ---- ---- - -_Tr_ -- ---- - - - - -- - _, 9L a SALES It WASTE & VENT RISER DIAGRAM SCALE: NONE 10 UIL0IG WT SA , L CONNECT NEW 3/4" CW TO CW MAIN. FIELD VERIFY EXISTING COLD WATER MAIN LOCATION, SIZE, AND CAPACITY PRIOR TO BEGINNING OF WORK. PROVIDE PRESSURE REG. BACKFLOW PREVENTER AT POINT OF CONNECTION ROUTE 1/2" HW TO LAVATORY, 2" WASTE DN. &1-1/2" V. UP. INSTALL INSTANTANEOUS WATER HEATER UNDER THE LAVATORY. ROUTE 1/2" CW DOWN TO LAVATORY & EXTEND 1/2" CW TO WATER HEATER. ROUTE 3/4" CW TO WATER CLOSET, 4." WASTE DN. & 2" V. UP. CONNECT NEW 3" VENT TO EXISTING THROUGH ROOF OR RUN 3" V.T.R. AS INDICATED. LOCATE & CONNECT NEW 4" SANITARY TO BUILDING MAIN SANITARY. FIELD VERIFY EXACT LOCATION OF EXISTING SANITARY PIPE PRIOR TO BEGINNING OF WORK. PROVIDE TRAP PRIMER FOR FLOOR DRAIN. REFER TO SPECIFICATIONS FOR MODEL AND MANUFACTURER. INSTALL TRAP PRIMER VALVE ASSEMBLY IN WALL AT AN ACCESSIBLE HEIGHT. PROVIDE ACCESS PANELS AS REQUIRED. ROUTE 2" WASTE DN. & 1 -1/2" V. UP. O ROUTE 1/2" CW DOWN TO DRINKING FOUNTAIN, 2' WASTE DN. & 1 -1/2" VENT UP. LABEL ALL PIPING. IiECEEVED RF JAN 22 r'"'-'3 '4; F IorrF6eL y 6a�i\ I • • I • associates • ARCHITECTURE • INTERIORS • PLANNING 2747 19th STREET SAN FRANCISCO, CA 94110 PH: 415 - 362 -5857 FX: 415 -362 -5044 B ARE E SCENTUALS 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 -5478 THESE PLANS AI SPECIFICATIONS, AS WELL AS BARE ESWWITUALS NAM AND LOGO. TRADEMARKS ANB DESIGNS ARE THE EXCLUSIVE PROPENr•/ OF BARE ESCENTUALS. ANY REPRODUCTOI, MODIFICATION, =LASINE MAR R LSE OF THESE MATERIALS PR ANY PORTION OF D EM WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PRONBTTED. REV DATE DESCRIPTION 10/12/07 DD SET 12/07/07 CD SET 01/09/08 PCC SET a 4t 4 H z U C 0 rr VJ 0 PROJ. NO.: PM: JC: CHECKED: SHEET TITLE: cu co 2 co r cu < -L--r C6 0 co I- 7.112 A.M. A.C. SCALE: (DO NOT SCALE DRAWINGS) PLUMBING FLOOR PLAN P -1 ,4,A y 'Q: ■ ■ III PLUMBING NOTES 1. THE PLUMBING CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR THE PLUMBING WORK UNLESS PROVIDED BY OWNER. 2. ALL WORK SHALL CONFORM TO ALL LOCAL CODES THE UNIFORM PLUMBING CODE, HEALTH AGENCY REGULATIONS, ATE BUILDING CODE REQUIREMENTS FOR ACCESS TO THE HANDICAPPED AND STATE ENERGY CO N REQUIREMENTS AND ALL OTHER GOVERNING LAWS OR 3. STRAP TANKS SECURELY TO STRUCTURE. 4. INSULATE ALL HOT WATER PIPING AS REQUIRED BY U.P.C. -1994. 5. LAVATORIES IN REST ROOMS OF PUBLIC FACILITIES SHALL BE EQUIPPED WITH: A OUTLET DEVICES THAT LIMIT THE FLOW OF HOT WATER MIN. 120 DEG.F) TO A MAXIMUM OF 0.5 GALLONS PER MINUTE, OR WITH; B. SELF- CLOSING FAUCETS THAT LIMIT DEUVERY TO A MAXIMUM OF 0.25 GALLONS OF HOT WATER FOR RECIRCULATING SYSTEMS AND TO A MAXIMUM OF 0.50 GALLONS FOR NON- RECIRCULATING SYSTEMS . 6. CROSS SECTIONAL AREA OF VENTS THRU ROOF SHALL NOT HE LESS THAN LARGEST REQUIRED BUILDING SEWER . 7. PROVIDE CLEAN OUTS ON ALL BRANCHES OVER 5' -0 ". B. SIZE OF TRAPS AND TRAP ARMS SHALL COMPLY WITH 2003 U.P.C. 9. PROVIDE VACUUM BREAKERS ON ALL HOSE BIBBS. 10. PROVIDE Shutoff VALVE ON COLD WATER SIDE OF WATER HEATER 11. COORDINATE SIZE AND LOCATION OF METER, INCOMING WATER AND SEWER LINES WITH LOCAL UTILITY AGENCIES. NOTIFY OWNER'S REPRESENTATIVE OF THE UTILITY HOOK -UP FEES OR ASSESSMENT COSTS AS SOON AS THEY CAN BE DETERMINED. NOTIFY OWNER'S REPRESENTATIVE AT ONCE IF PUBLIC SEWER OR WATER SERVICE IS NOT AVAILABLE TO THE SHE. 12. THE PLUMBER SHALL CONNECT ALL WATER PIPING TO FOOD SERVICE EQUIPMENT, ICE MAKER, HAND SINK AND SERVICE SINK. FURNISH AND INSTALL ALL FAUCETS AND CONNECT ALL PIPING AND DRAINS. FURNISH AND INSTALL THE SHORT HOSE AND HANGAR REQUIRED AT THE MOP SINK. 13. REFER TO THE FIXTURE SCHEDULE FOR EQUIPMENT LOCATION AND SPECIFICATIONS. REFER TO THE HVAC, WALK -IN COOLER AND ROOF PLANS FOR LOCATION AND SIZE OF Condensate DRAINS. 14. WHERE PRACTICAL LOCATE ALL WATER LINES OUT DF THE CONCRLIL FLOOR SLAB. INSTALL ABOVE CEILING WITH RISERS WITHIN WALLS TO FACILITATE FUTURE PLUMBING WORK INSTALLATION. 15. LOCATE ALL PLUMBING VENTS A MINIMUM OF 10' HORIZ. OR MINIMUM 3' ABOVE MECH. AIR INTAKES AT AIR COND. UNITS & HOOD MAKE UP AIR BLOWER. 16. THE PLUMBING CONTRACTOR SHALL COOPERATE WITH ALL OTHER INVOLVED TRADES, EQUIPMENT INSTALLERS AND CONTRACTOR'S. THE PLUMBING CONTRACTOR SHALL PICK UP AFTER HIS OWN WORK AND EACH DAY LEAVE THE FACILITY IN A BROOM CLEAN CONDITION. 17. SERVICE SINK AND/OR FLOOR SINKS SHALL ACCEPT CONDENSATION DISCHARGE FROM RODE MOUNTED AIR CONDI11ONER AND COOLER FAN UNIT, AND DISCHARGE FROM WATER HEATER PRESSURE RELIEF VALVE. SINK TO BE USED SHALL BE DETERMINED. 18. FLOOR SINKS INTENDED FOR FUTURE USE NOT KNOWN AT THIS TIME) SHALL HAVE A TRAP PRIMER UNE CONNEC ED FROM DRAIN UNE TO COLD WAILl1 LINE WITH TRAP PRIMER. 19. FABRICATOR TO FURNISH AND INSTALL ESCUTCHEON PLATES AT EVERY LOCATION WHERE A PIPE PASSES THRU A WALL. 20. ALL WASTE AND VENT LINES TO BE CAST IRON PIPE. 21. EACH FIXTURE TRAP SILL NOT EXCEED 36" FOR 1 1/2" o LINE, 60" FOR 2" o LINE OR 72 FOR 3 % LINE. 22. UNLESS PROHIBITED SIRUCTURALLY, EACH VENT SHALL RISE VERTICALLY NOT LESS THAN 6" ABOVE FINISHED FLOOR. 23. HORIZONTAL DRAINAGE PIPING SHALL MAINTAIN A UNIFORM SLOPE OF 1/4 PER FOOT AND PROVIDE A CLEAN OUT FOR EACH AGGREGATE CHANGE OF DIRECTION EXCEEDING 135. 24. VENT UNES EXTENDING TO ROOF SHALL EXTEND THRO1.1GH ITS FLASHING AND SHALL TERMINATE VERTICALLY NOT LESS THAN 6 ABOVE THE ROOF NOR LESS THAN 12" FROM ANY VERTICAL SURFACE. 25. ALL WASTE AND VENT UNE SUNDER BUILDING TO BE SUPPLIED AND INSTALLED BY FABRICATOR. 26. ALL LINES THAT ARE DROPPED BELOW THE BASE FRAME WILL BE REMOVED FOR SHIPPING, REINSTALLED AND TESTED IN THE FIELD BY GENERAL CONTRACTOR. 27. CONTRACTOR SH VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE, NOTIFY SHELL REPRESENTATIVES OF ANY DISCREPANCIES BETWEEN SITE AND PLANS, PRIOR TO COMMENCING WORK. 28. ALL BACKFILL OF UTIUTY TRENCHES SHALL BE CLEANED WASHED SAND OR PEA GRAVEL. 29. CONTRACTOR SHAL FEILD VERIFY EXACT DEPTH AND LOCATION OF EXISTING SEWER LATERAL PRIOR TO EXCAVATION OF FOUNDATIONS AND TRENCHES. GENERAL NOTES: 1. WATER HEATER TO MEET THE REQUIREMENTS OF THE STATE AND LOCAL ENERGY COMMISSION. 2. PROVIDE TRAP PRIMER FOR FS AND FO. (WHEN APPLICABLE). 3. FOR HANDICAPPED REQUIREMENTS,SEE ARCHITECTURAL DRAWINGS. 4. a) SEWER OR WASTE TO BE CAST IRON ABOVE AND BELOW GRADE AND GALVANIZED STEEL ABOVE GRADE. b) HOT AND COLD WAILk TO BE COPPER TUBING, TYPE "L ". c) CONDENSATE PIPE TO BE COPPER TUBING TYPE "M" FOR AC UNITS. d) GAS PIPES TO BE SCHEDULE 40 BLACK STEEL OR GALVANIZED SILL 5. PROVIDE AND INSTALL NEW TEES AND WYES FOR EACH WATER OR SEWER POINT OF CONNECTION. 6. THE NONRESIDENTIAL ENERGY CONSERVATION STANDARDS HAVE BEEN REVIEWED AND THE DESIGN, DRAWINGS AND CALCULATIONS COMPLY SUBSTANTIALLY WITH THESE STANDARDS. 7. LAVATORY FAUCETS AND SINK FAUCETS (NOT INCLUDING SERVICE SINK FAUCETS) SHALL MEET THE FLOW REQUIREMENTS OUTLINED IN THE APPLIANCE EFFICIENCY STANDARDS. STANDARDS T20 -1525. 8. ALL APPLIANCES INSTALLED INCLUDING WATER HEATERS, SHOWER HEADS, LAVATORY FAUCETS, SINK FAUCETS...SHALL BE CERTIFIED TO THE ENERGY COMMISSION BY ITS MANUFACTURER, AND TO COMPLY WITH THE EFFICIENCY STANDARDS FOR SUCH APPLIANCES 9. CODES, RULES AND REGULATIONS - DESIGN OF SYSTEM: A THE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM PLUMBING CODE IS HEREBY MADE A PART OF THIS SPECIFICATION AS A STANDARD OF MINIMUM REQUIREMENTS. IN ADDITION ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES AND CODES, AND WITH THE LATEST RULES OF THE NATIONAL FIRE PROTECTION ASSOCIATION. B. WHEN THE DRAWINGS CALL FOR MATERIALS OR CONSTRUCTION OF A BETTER QUALITY OR LARGER SIZES THAN REQUIRED BY THE ABOVE MENTIONED CODES AND RULES, WORK SHALL BE AS SPECIFIED OR SHOWN RATTIER THAN AS REQUIRED BY CODE. ALL ITEMS OR FEATURES OF THE PLUMBING SYSTEMS REQUIRED BY CODE SHALL BE INCLUDED, EVEN THOUGH NOT SPECIFIED HEREIN. . C. INSTALLATION OF THE SYSTEMS SHALL BE IN ACCORDANCE WITH ABOVE MENTIONED CODES AND REGULATIONS AND ALSO SHALL CONFORM TO GOOD, ACCEPTED PLUMBING PRACTICES. 10. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DEPTH OF EXISTING LINES, LATERALS, AND WYES BEFORE STARTING. SHOULD IT BE NECE55ARY TO REROUTE LINES DUE TO CONDHIONS FOUND ON THE SITE OR IF INDICATED POINTS OF CONNECTIONS CANNOT BE MADE TO THE LINES AS FOUND, THE CONTRACTOR SHALL, BEFORE CONTINUING, NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH MAY BE AFFECTED. 11. ALL PLUMBING FIXTURES TO BE APPROVED BY ENERGY CONSERVATION STANDARD. 12. HOT WATER PIPE INSULATION MUST BE BASED ON INSULATION OF R VALUES BETWEEN 4.0 AND 4.6. A AT 1' OR SMALLER PIPES, 1' INSULATION THICKNESS. B. AT 1 -1/4" TO 6" PIPES, 1 -1 /2" INSULATION THICKNESS. PLUMBING FIXTURE SCHEDULE WATER CLOSETS (PIA) HANDICAPPED FIXTURE CONNECTION SCHEDULE PLUMBING LEGEND S APp ,1t7' R E. f P DESCRIPTION WASTE TRAP VENT HOT WATER COLD WATER SYMBOL DESCRIPTION FIXTURE: FLUSH TANK "KOHLER ", K 3544, EQUAL AMERICAN STANDARD, WATER SAVER (1.6 GPF), EQUIPPED WITH SEDAN FLUSHMATE, 17 -1/2" HIGH ELONGATED BOWL WHITE VITREOUS CHINA. PROVIDE COVER SEAT. FLOOR MOUNTED, BOTTOM OUTLET, 3E' PROJECTION IN FROM WALL, 10" TO CENTERLINE OF OUTLET FROM FINISHED WALL, WATER SURFACE AREA SEAL BALLPA55 AND OPERATION MEETS OR EXCEEDS ANSI A112.19.2M CODE REQUIREMENTS, 2 -BOLT CAPS #481310 PROVIDE OPEN FRONT SEAT AS REQUIRED. LAVATORIES (P2A) HANDICAPPED P1A FLOOR SET FLUSH TANK WATER CLOSET (A.D.A 4" TNT. Z N.A. 3/4" ■ ...-"1611111 �� L H • •I RY A. • - 2" 2" 1 -1 4 " X 1 -1 /2" 1 -1 /2" 1 - 1 /2 1/2" N T 1/2 _ " 1 /2 1/7's' SANITARY SANITARY/WASTE PIPING, 5, W / VENT, V COLD WATER PIPING, CW � P2A DF -1 _ DRINKING FOUNTAIN V REFER TO ARCHITECTURAL ELEVATIONS PLA' OR MOU G HEIGHT OF ALL FIXTURE � i\ � � �� � -- - HOT WATER PIPING, HW DRAWING LIST k �� , r / ' FIXTURE: AMERICAN STANDARD 110124.131 "COMRADE" WALL HUNG LAVATORY, WHITE VITREOUS CHINA, FAUCET LEDGE, REAR OVERFLOW, 4" CENTERS ON FAUCET HOLES, 2O" X 18 -1 OVERALL DIMENSIONS, "D" SHAPED BOWL 15" X 10 -7/8" X 6 -1/4" DEEP, SELF DRAINING DECK AREA WITH CONCEALED ARM SUPPORT. PROVIDE SINGLE LEVER HANDLE WITH MIXING VALVE. CHRDM PLATED P - TRAP & HARDWARE FOR. ADA COMPUANCE. INSTALL W/ PROTECTNEWRAP. CARRIER ZURN COMPANY Z -1231 SERIES, FLOOR MOUNT, SINGLE LAVATORY CARRIER W/ CONCEALED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS AND BLOCK BASES, SECURED TO FLOOR W/ )" BOLTS AND ANCHORS. APPROPRIATE MODEL TO SUIT WALL CONSTRUCTION AND TYPE OF FIXTURE PURCHASED. FLOOR DRAIN (FD -1) FIXTURE: GATE VALVE r , �J F P -1 PLUMBING FLOOR PLAN e ■ ■ associates • ARCHITECTURE • INTERIORS • PLANNING P -2 PLUMBING NOTES AND SCHEDULES & DETAILS 0 CO CLEANOUT ® FLOOR DRAIN, F.D. CW COLD WATER HW HOT WATER 274719th STREET FRANCISCO, CA 94110 SAN PH: 415 FX: 415-362-5044 w E ri E 5 C E N T LT A L S 71 STEVENSON STREET 22ND FLOOR SAN FRANCISCO, CA 94105 (415) 489 - 5478 x ' � VALVE m 3 DOMESTIC COLD WATER UNE TRAP PRI MER VALVE WITH BACKFLOW PREVENTOR AND VACUUM BREAK DISTRIBUTION UNIT FOR TERMINATE SLEEVE FLUSH STANDARD WEIGHT STEEL PIPE SLEEVE OF SIZE TO PASS PIPE AND INSULATION I , ZURN COMPANY SERIES ZN- 415 -P, COATED CAST IRON FLOOR DRAIN, WTM "PRIMER TAP, TWO -PIECE BODY, DOUBLE DRAINAGE FLANGE, INVERTIBLE NON- PUNCTURING FLASHING COLLAR, WEEPHOLES, BOTTOM OUTLET INSIDE CAULK CONNECTION, ADJUSTABLE ROUND SUPER TEED STRAINER, FLASHING CLAMP WITH 24" X 24" 4 LB. LEAD FLASHING FOR FLOOR DRAINS INSTALLED ABOVE SLAB ON GRADE. ADJUSTABLE SQUARE "TYPE 5" STRAINER FOR ALL DRAINS LOCATED IN TILED AREAS. STRAINER ZURN COMPANY TYPE C, 5" DIAMETER POLISHED NICKEL BRONZE FINISH. WASTE SIZE AS NOTED ON DRAWINGS, CAST IRON P -TRAP UNDER FLOOR. INSTALLATION DIMENSION 15 1 / " 4 SUPPLY - �� T UBE YS -8 _� WITH FINISHED WALL SURFACES SEAL OR CAULK SLEEVES � ` THRU FIRE WALLS IN A "�,�,�,�...�,�.1.�,� SMOKE TIGHT MANNER � ' ! � ,•. -10 �f���V�� ♦'�� _ _ _ _ . , • ∎• ∎���♦ MULTIPLE FLOOR DRAINS ., . ,.,., ,,., ,. �...A.�.�.�,�.,��.�. 1 SPECIFICATIONS, AS AS UALSHAKE AND LOGO. TRADEMARKS AND DESIGNS ARE DE pfttUSIVEPROPERTYOF euaEesmnu�us AMYREPRa�UCfIa1.N001RGT1�1 OSOASURE w use o� n nelMATERIALS NIR ANY PORTION a� I wmiour �ririr itititititititititi riiiriiirir � _4 i * * _ = /riiiiiriii� _ _•_•_ * _•. r STRICTLY PRIM r . NIMBI COHSE/ IS s PIPE AND INSULATION TO BE CENTERED IN SLEEVE DO NOT SUPPORT PIPE FROM SLEEVE rfrr rr .J FINISHED ESCUTCHEON PLATE FLUSH REV DATE DESCRIPTION 10/12!07 DD SET 12/07/07 CD SET 01/09/08 PCC SET AGAINST WALL AND OF SIZE TO COMPETELY COVER OPENING FINISHED WALL SURFACE PLUMBING SPECIFICATIONS EXCAVATION AND BACKFILL 3 MINIMUM /a COPPER FLOOR DRAIN TRAP MAKE - UP WATER LINE. (TYPICAL) VIEW DRINKING FOUNTAIN (DF -1) CONCEALED PIPING PIPING EXPOSED TO DO ALL EXCAVATION AND BACKFILLING. LAY SEWER AND UNDERGROUND PIPING LINES ON 6" COMPACTED SAND. BACKFILL UNDER BUILDING AND ALL DRIVES, ROADS AND WALKS WITH BANK -RUN GRAVEL PIPE JOINTS AND CONNECTION INTERIOR WALLS OASIS WATER COOLER MODEL PRSACSL SANDTONE COLOR, STAINLESS STEEL TOP, DUAL HEIGHT, WALL MOUNTED, TWO ONE PIECE FOUNTAINS WITH CONTOURED BASINS, PUSH BUTTON VALVES, CHROME PLATED BUBBLER AND WASTE STRAINERS, MATCHING STAINLESS STEEL BACK PANEL, VANDAL RESISTANT BOTTOM PLATES AND 1 -1/4" NPT TRAPS. PROVIDE APRON FOR ADA COMPLIANCES. WALL CLEANOUT (WCO 1 '.•.'SEWENGA5ES *. *. *. *. .* : WATER TRAP NOTE: I / va ,es C v ' ti :sue I'L' y , 29919 4 � f 5 ,�� � "' ONA L $�~ f ALL CUTTING AND PATCHING OF FINISHED CONSTRUCTION OF BUILDING SHALL BE PERFORMED BY THIS CONTRACTOR UNDER THE SECTION OF SPECIFICATIONS COVERING THESE MATERIALS. ANY MINOR ADJUSTMENT IN LOCATION OF ALIGNMENT OF NEW WORK OR TO CONNECT TO EXISTING UTILITIES SHALL BE PERFORMED AS DIRECTED BY THE ARCHITECT WITHOUT ADDHIONAL COST TO THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO THE GROUNDS, WALKS, ROAD, BUILDING, PIPING SYSTEMS, ELECTRICAL SYSTEMS, AND THEIR EQUIPMENT AND CONTENTS, CAUSED BY LEAKS IN THE PIPING SYSTEMS BEING INSTALLED OR HAVING BEEN INSTALLED BY HIM. HE SHALL REPAIR AT HIS EXPENSE ALL DAMAGED SO CAUSED. ALL REPAIR WORK SHALL BE DONE AS DIRECTED BY AND IN SUCH MANNER AS SATISFACTORY TO THE ARCHITECT. OWNER RESERVES THE RIGHT TO MAKE EMERGENCY REPAIRS AS REQUIRED TO KEEP EQUIPMENT IN OPERATION WITHOUT VOIDING THE CONTRACTOR'S GUARANTEE BOND NOR RELIEVING THE CONTRACTOR OF HIS RESPONSIBILTHES DURING THE BONDING PERIOD. INTERRUPTION OF SERVICES TRAP PRIMER VALVE SHALL BE MOUNTED ONE FOOT ABOVE THE FINISHED FLOOR FOR EVERY 20 FEET OF PRIMER LINE. TRAP PRIMER DETAIL SCALE 0 PIPE SLEEVES THROUGH WALL DETAIL SCALE 0 WALL: ZURN COMPANY #Z -1446. COATED CAST IRON CLEANOUT TEE, HUB AND SPIGOT CONNECTION, BRONZE PLUG. COVER: ROUND STAINLESS STEEL WALL ACCESS COVER WITH SCREW. WATER HEATER (WH -1) NOT TO SCALE NOT TO SCALE HOT VAL COLD VAT. CARPE MPRARKER WHERE OCCURS. CLEANOUT WITH COVER CL OVIDE F OR DUTY REQUIRED FINISHED FLOOR INSTANT. FLOW TYPE. CHRONOMITE MODEL S -3OIL 2.3 KW, 208V/10, 60 HZ TRAP PRIMER 1 /2'HW. UNION (TYP) d ° ° ° ° ° c ° a ° ° ° a ° - LONG SWEEP 1/4 BEND OR CAST IRON COMB, "Y & 1/8 BEND. (USE REDUCING TYPE WHERE REQUIRED) I EXTENSION 1/2' CW. ' ' v PRECISION PLUMBING PRODUCTS #PR -500 TRAP PRIMER. MOUNT ABOVE CEILING. WATER HAMMER ARRESTER (WHA) - SAME SIZE AS SEWER TO 4" DIA. Field Soutl ithcenter Mall WA 98188 & King Count; WHEN IT IS REQUIRED TO INTERRUPT EXISTING SERVICES, THIS CONTRACTOR SHALL FIRST NOTIFY THE ARCHITECT THAT AN INTERRUPTION IS REQUIRED. IT SHOULD BE NOTED THAT FACILIHES MUST BY KEPT IN OPERATION AS MUCH AS POSSIBLE. THIS CONTRACTOR SHALL ADVISE THE ARCHITECT OF THE LENGTH OF TIME THE SERVICE WILL BE INTERRUPTED AND SHALL GET PERMISSION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. WARRANTY CW. INLET SIOUX CHIEF MODEL HYDRA - RESTER ENGINEERED WATER HAMMER ARRESTER WITH SEAMLESS CONSTRUCTION. ASE 1010 POI AND ANSI APPROVED WITH NO ACCESS PANELS REQUIRED. THERMOSTATIC MIXING VALVE (TMV) .Imi■ ■ ELECT. box UNDER LAV. INST. WATER HEATER al'll ALIT SYMMONS TEMPCONTROL 5 -400 CLEANOUTS DIRECTION C THIS CONTRACTOR SHALL WARRANT THAT ALL WORK UNDER THIS SECTION SHALL BE FREE OF DEFECTIVE WORK, MATERIALS AND PARTS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE WORK AND SHALL REPAIR, REVISE, AND REPLACE, AT NO COST TO THE OWNER, ANY SUCH DEFECTS OCCURRING WITHIN THE WARRANTY PERIOD. BUILDING DRAIN OR SEWER MATERIAL AND SIZE AS SPECIFIED JOSAM, SMITH, WADE, ZURN OR WATTS FLOOR, ZURN Z- 1420 -2. WALL, ZURN Z -14 46 . GRADE, ZURN Z -1455. FLOOR DRAINS INSTANTINEOUS WATER HEATER DETAIL SCALE 4 CLEAN OUT DETAIL SCALE JOSAM, SMITH, WADE, ZURN OR WATTS NOT TO SCALE NOT TO SCALE FIELD VERIFY ALL CONDITIONS CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DEPTH OF EXISTING LINES, LATERALS, AND WYES BEFORE STARTING. SHOULD IT BE NECESSARY TO REROUTE LINES DUE TO CONDITIONS FOUND ON THE SITE OR IF INDICATED POINTS OF CONNECTIONS CANNOT BE MADE TO THE LINES AS FOUND, THE CONTRACTOR SHALL, BEFORE CONTINUING, NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH MAY BE AFFECTED. NO.: 7.112 PM: A.M. JC: A.C. CHECKED: DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICAT10N5 MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. HANGER NU I LOCKING NUT 3/ COND. DRAIN D HANGER ROD LOCKING NUT I �� SUPPORT NUT SUPPORT NUT HEAVY DUTY CLEVIS HANGER VAPOR BARRIER PIPE INSULATION LINE DOWN IN WALL /4 CONDENSATE THRU WALL AND j �� - HEAVY DUTY CLEVIS HANGER SCALE: (DO NOT SCALE DRAWINGS} FOR ADDITIONAL MALL REQUIREMNTS, SEE MALL DESIGN CRITERIA & DETAILS LAV TURN DOWN INTO RECEPTACLE SHEET TITLE: PLUMBING NOTES DETAILS I & SCHEDULE PIPE 16 GA. ZINC COATED SHEET STEEL SADDLE S " LONG MINIMUM C L EVIS HANGER CLEVIS HANGER SINGLE HORIZONTAL RUNS SINGLE HORIZONTAL RUNS NO VAPOR BARRIER INSULATION WITH VAPOR BARRIER INSULATION HUB OR FUNNEL m MI TYPE RECEPTACLE �I I � �� �- F E f tl �!ED CIrYflF VII;. - ,'.9 JAN 22 '�" ■ PIPE TO BE SAME SIZE AS SINK TAIL PIECE F�P:3Wa6 I t+I.a� e 1`1/ " tom, TYP. PIPE SUPPORT DETAIL NOT TO SCALE CONDENSATE DRAIN CONNECTION DETAIL NO SCALE