HomeMy WebLinkAboutPermit D97-0019 - ALLIED INTERNATIONAL EXHAUST - STORAGE RACKSCity of Tukwila
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
DEVELOPMENT PERMIT
WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES,
APPLICANT IS PROCEEDING AT THEIR OWN RISK.
Parcel No: 352304 -9097 Permit No: 097 -0019
Address: 1165 ANDOVER PK W Status: ISSUED
Suite No: Issued: 01/31/1997
Location: Expires: 07/30/1997
Category: ACOM
Type: DEVPERM
Zoning: C -M
Const Type: Occupancy: WAREHOUSE
Gas /Elec.: UBC: 1994
Units: 001 Fire Protection: SPRINKLERS
Setbacks: North: .0 South: .0 East: .0 West: .0
Water: TUKWILA Sewer: TUKWILA
Wetlands: Slopes: N Streams:
Contractor License No:
OCCUPANT ALLIED INTERNATIONAL EXHAUST
1165 ANDOVER PK W, TUKWILA, WA 98188
OWNER WAREHOUSE PROPERTIES ASSOC Phone: (206)775 -9127
300 ADMIRAL WY, EDMONDS WA 98020
CONTACT PAUL KVAN Phone: 206 575 -1425
1165 ANDOVER PARK WEST, TUKWILA, WA 98188
***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Description:
INSTALL 12' HIGH RACKS IN EXISTING WAREHOUSE.
****************************************************** * * * * * * * * * * * * * * *,r * * * * * * * * * * * * **
Construction Valuation: $ .00
PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng..Appr:
Curb Gut /Access /Sidewalk /CSS: N
Fire Loop Hydrant: N No: Size(in): .00
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Cut: Fill:
Landscape Irrigation: N
Moving Oversized Load: N Start Time: End Time:
Sanitary Side Sewer: N No:
Sewer Main Extension: N Private: N Public: N
Storm Drainage: N
Street Use: N
Water Main Extension: N Private: N Public: N
***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOTAL DEVELOPMENT PERMIT FEES: $ 54.00
***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Center Authorized Signature:
(206) 431 -3670
Date 1
I hereby certify that I have read and examined this permit and know the same
to be true and correct. All provisions of law and ordinances governing this
work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or
cancel the provision of a ether state or local laws regulating construction
or the perfor of wo g sv am authorized to sign for and obtain this
developm- t t.
Signature:_ Date:,1�31.-3)
Print Name:_LAVAlkrif
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or abandoned
for a period of 180 days from the last inspection.
Andress 1165 ANDOVER FY W Permit. No 097 -;0019
Suite
;.Tenant Sstatus ; ISSUED
Tvp'e Q Appli : ed 0/24 1997
Parcel.# 352304. 9Q 7 •Issued :01 /31%1997: • •
k. l. A*. kAA* A* k' ikk *.Ar_ *kA *. * :�tk•kk-A * *k, * **A* � * * * * *k *'k *k. *, * *k *ktit *k *** k; * *k.AAAk•AAkA * *'Akb
Perrit,_Conditions
1 No changes wil;lr be: made •to the plans` :unl'ess approved 'by the
Architect 'or Engin eer and • the Tukwil
o a Building D :ivision
11 permits inspectin .recur ds ;`anat. :41 pr�.o ved' : plsans shall : 'be
"131'
l e .at the i site prior to the st art of • anv .ca
truct,i on Th ese documents :are to- be ma nta i' e d and ava i 1.-
able until t anal 'i'rispect.i.on
•approval is gran 4Y
• All co.nstructltn .be done :in conf cr r .manc :e with a proved
plans `and, ;equiremerits of the, Uniform {dui "ld,ing Code' (1;9 '
Edit ion) `a .` amendedi Uni,fornt_: Mechani'oal Code "( } 1 ( 994,; Edition
grid Washitri ton ,estate Energy: Code$ (1994 Edi t i on> " 1
Rack i nsta 1 l ati sons 'sha.l l desp lfay i n., one or' more co'nsp i cuous
locations ;a permanent plaque: each tint less titan 50. squar e;
i.rtche�S'Hl�;area and showing the maximum permissible unit load
in 'c1'ear legible print. r, s �y
Va :idi'tvk,oi Permi The • issuance of a permit- or a:ppr oval of
plans. spa n f tions. and ccimputations shall not. be
st e a: perm :it :for or an, appr oval of, any violation'
at�, any of the 'provisions of :the "bu i 1 d i ng code or o;f arty
other or dinanca= afn...the jurilsdiction „No .perm pr : t�
give? :author�itv.''to;v" plate or'. • cancel : th ,;provisions of • this'
cods %.sflall .be'; :valid : n
x f 1
•
Project NamelTenant:
ML t r� IA) ef•N 04/ma(
x 6,44E4
Value of Construction:
100. C I
Site Address: „�
114 S A +wQooev Fa v
... ---C'ry /Zip:
C. �t State � i k u1&
:
Parcel Number 0 1.909 7.03
Tax g a �. c-z 3
Property gwner: 1
LA: ve.14010S e b gt
Will there be a change of use? CI yes L!l no
n -
11 558 C. ,
Phone:
.32T -• 2 O 7 S_...
S reef Addree�
�32 4c'i►w tee pls�c��Ce
Ci State /Zip:
4 az
Fax #:
Contact P: erso
�•1.� V v1
Phone:
A — 'I 5 - - ) 4z4-
Street Address: Gs ^ n ) , T ' L0. t r e p'
11 /�tA,Otl?QV �/ (�J
Fax #:
Contractor:
Phone:
Street Address:
City State /Zip:
Fax #:
Architect:
Phone:
Street Address:
City State /Zip:
Fax #:
Enginee% A
Phone: � 7 S , /
S ess: 'l
v treet z 2 Addr S L3 . l004. L k t.. 1�
l e ,
C��' , St
` St o � ate /Zip:
Z
Fax #:
2� 1c - S 7 s""- eSo lb
to be �pnek . s.4 6 �� G r t
Description of � ` (,
/ s�/ 1 / W 1 t S
( l!s
Existing use: ❑ Retail ❑ Restaurant
❑ Church ❑ Manufacturing
— ❑ School /College /University
,
❑ Multi- family Warehouse Hospital
❑ Motel/Hotel ❑ Office
❑ Other
Proposed use: ❑ Retail ❑ Restaurant
❑ Church ❑ Manufacturing
❑ School /College /Universit
❑ Multi - family ft KVarehouse Hospital
❑ Motel /Hotel ❑ Office
❑ Other
Will there be a change of use? CI yes L!l no
If yes, extent of change: (Attach additional sheet if necessary)
Will there be rack storage? CI no
, yes
Existing fire protection features: prinklers ❑ automatic fire alarm ❑ none ❑ other (specify)
lid s °0
Building Square Feet: j S15t�//
existing
Area of Construction: (sq. ft.)
Will there be storage of flammable /combustible hazardous material
Attach list of materials and storage location on separate 8 1/2
in the building? ❑ yes l.� no
X 11 paper indicating quantities & Material Safety Data Sheets
•
r
Commercial / Multi- Family Tenant Improvement / Alteration Permit Application
CTPERMIT.DOC 7/9/96
CITY OF r IKWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mall or facsimile.
APPLICANT REQUEST FOR PUBLIC WORKS SITEICIVIL PLAN REVIEW OF THE FOLLOWING:
(Additional reviews may be determined by the Public Works Department)
❑ Channelization /Striping
❑ Land Altering 0 Cut cubic yds.
❑ Sanitary Side Sewer #:
❑ Storm Drainage ❑ Street Use
❑ Water Meter /Exempt #: Size(s):
❑ Water Meter /Permanent # Size(s):
❑ Water Meter Temp # Size(s):
❑ Miscellaneous
❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone
❑ Hauling
0 Fill cubic yds. ❑ Landscape Irrigation
❑ Sewer Main Extension 0 Private 0 Public
❑ Water Main Extension 0 Private 0 Public
0 Deduct 0 Water Only
Est. quantity:
gal Schedule:
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and
is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by
the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
Date application accepted:
Date application expires:
Applicatio to gy: (initials)
BUILD G O NE R AUTHO
AGENT:
Signal re: �...�r
Date: /+ 2 7
7
Print netaem- 1 i 0 t s + .
N_ aK
Pho7 /v 1 .-
Fax #:
s /
Addres/ 3 � N a JQ»
WC.
City /State /Z 44 hai
• g /g
ALL COMMERCIAUMULTI -FA Y TENANT IMPROVEMENT /ALT 'ATION PERMIT APPLICATIONS
MUBE SUBMITTED WITH THE FOLL• ING:
➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT,
STRUCTURAL ENGINEER OR CIVIL ENGINEER
➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ ❑ Complete Legal Description
❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Five (5) sets of working drawings, which include :
❑ ❑ Site Plan (including existing fire hydrant location(s)
1. North arrow and scale
2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas
5. Recycle collection location and area calculations (change of use only)
6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of
use only)
9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of
those, identify by size and species which are to be removed and saved
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change
of use only)
11. Location and gross floor area of existing structure with dimensions and setback
12. Lowest finished floor elevation (if in flood control zone)
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H-
9).
❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled
❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of
any hazardous materials; dimensions of proposed tenant space.
❑ ❑ Vicinity Map showing location of site
❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of
rack. Structural calculations are required for rack storage eight feet and over.
❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished
❑ ❑ Construction details
❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of
water supply to sprinkler vault with documentation from contractor stating supply line will meet or
exceed sprinkler system design criteria as identified by the Fire Department.
❑ ❑ Washington State Non - Residential Energy Code Date shall be noted on the construction drawings.
❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds).
❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
land use or SEPA decisions.
❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of
Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5)
❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no
contractor has been selected at time of application a copy of this license will be required before the
permit is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal
I HEREBY CERTIFY THAT ! H/(V6"READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PSM BY TH
THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
CTPERMIT.DOC 7/9/96
s tt t� x . ;rya ;:�• t,
*** *k **hk * * * *k * *k * *, *k kit* k********** ** * * ** * **kk** *** * *k ** * *:l ***h
S- I1Y:'.OF 1UKWILA.:WA TRANSMIT
- **A* * ** *k ** *.l*kkk* *A *** * * k . A *•h **it **k*•A* *k****k ******
TRANSMIT Number: R9700533 ''Amount: 54.00 01/24/97 11:42
Payment; Method: CHECK Notation: .ALLIED .INTERNAf . Init: SLI3
Permit No 1)97 -0019 Tvne:.DEVPERM DEVELOPMENT PERI4IT
'Parcel No ' :35 43044- 909
Site Address:
TN►is 1163 .ANDOVER
Payment
".54.00
PK
r.�
* * * *** * * * *•k ** * **
Account "Code
000/322.104
000/343.830
000/386.904
4�
Total Peer: 54.
Tota1.-ALL hots: 54.00
Balance: q00
** ** * * "* *k * * ** * * *.4 * *0- * *4,* * *4•* • *,lk *A4,4, 4A�t * **
- :Description
BUILDING - .NONRES
PLAN CHECK - NOWRES
STATE BUILDING SURCHARGE
770 01127 411.7
Amount
30.00
19.50
4,50
TOTAL 54.00
HN-mb la . ts . r i coA T
Type of ins ctior -, jA
� I
r ss:
(Ai pit s AWbiER ice
Date called:
2. — 7-:7 --
Special instructions:.
5.044.
, t -Y A. 1A:: pc Ise
Date wanted. - �7 p.m.
Requester p ! V �0/V
P � t �' !-
Phone No.:
75 — I
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY: OF TUKWILA BUILDING DIVISION
6300 Southcenter .Blvd., #100, Tukwila, WA 98188
Pit-
`OOt
PERMIT NO.
2.Q. 431 -3670
COMMENTS:
Inspect
Approved per, applicable codes.
<
Corrections required prior to approval.
dirt0711111111r
Aor
Date:
fY
gat/
El $42.00 REINSP 1 TION E REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
Ifia1 4.4 4460 ,1 AP l Id.{iJ ?WwS6'l.'Y:. 4
Project: f y � q •
�
Type of inspection:
] � �
(
Address:
Date called:
Special instructions:
Date wanted: 21 - / 1
:::: : L
l
:. 5 _ 75 ._
i 4 , 2 _ 5 _
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF :TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206) 431 -3670
Approved per applicable codes. (Corrections required prior to approval:
COMMENTS:
(Y)TA-1 vA
Inspector:
(-;"‘ „LA_
Date:
$42.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection,
[ReceiPt No.:
Y.,X1967 k/a sati lArivAz,r rx r to t Afrt air ,s :: i�, �. r br►+:.e..r ,
Date:
Name 4///4_z P �/ i� /7 Tivivi"9/ -)C/! t."(
HI eAA Suite #
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
Authorized Signature
City of Tukwila John W. Rants, Mayor
Fire Department Thomas P. Keefe, Rre Chief
TUKWILA FIRS DIPARTMRNT
FINAL APPROVAL FORM
Retain current inspection schedule
Needs shift inspection
Y Approved without correction notice
Approved with correction notice issued
f o
Permit No.
Pri< Ks
FINALAPP.FRM T.F.D. Form F.P. 85
s' /q7
D te(
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439
ACTIVITY NUMBER D97 -0019 DATE 1/24/97
PROJECT NAME ALLIED INTERNATIONAL EXHAUST
DEPARTMENT:
P e) B ING DIVISION
op to( eonc i ✓ �
PUBLIC WORKS ❑
REVIEWERS INITIAL
APPROVALS OR CORRECTIONS: (ten days)
REVIEWERS INITIAL
CORRECTION DETERMINATION:
C:ROUTE -F
Pue C.00rdra±ov Dopy
PLAN REVIEW / ROUTING SLIP
FIRE PREVANTION ❑ PLANNING DIVISION ❑
S 4 PERMIT CO U
NYC
DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 1/28/97
COMPLETE ❑ NOT COMPLETE ❑ NOT APPLICABLE ❑
COMMENTS
TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED ❑
ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.)
DATE
APPROVED APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑
DATE
REVIEWERS INITIAL DATE
DUE DATE 2/11/97
DUE DATE
APPROVED n APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑
(Certification of occupancy required. )
PLAN REVIEW / ROUTING SLIP
ACTIVITY NUMBER D97 -0019 DATE 1/24/97
PROJECT NAME ALLIED INTERNATIONAL EXHAUST
DEPARTMENT:
BUILDING DIVISION
PUBLIC WORKS
REVIEWERS INITIAL
I
DETERMINATI N OF COMPLETENESS: (T,Th)
COMPLETE NOT COMPLETE El
COMMENTS
TUES /THURS ROUTING: PLEASE ROUTE NO FURTHER REVIEW REQUIRED
ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.)
t
1
APPROVALS OR CORRECTIONS: (ten days)
APPROVED El APPROVED W/ CONDITIONS
REVIEWERS INITIAL
C:ROUTE -F
CORRECTION DETERMINATION:
APPROVED n APPROVED W/ CONDITIONS
DATE l ^ `a1
REVIEWERS INITIAL DATE
FIRE PREVENTION PLANNING DIVISION El
STRUCTURAL El PERMIT COORDINATOR 0
DUE DATE 1/ 28197
NOT APPLICABLE 0
DUE DATE 2/11/97'
NOT APPROVED (attach comments)
DATE — 50 - `11
DUE DATE
NOT APPROVED (attach comments)
(Cerdfcatioo of occupancy required. )
a.�v.+.•..vu. i0.d#Ias7ibACW. Nit(
ACTIVITY NUMBER D97 -0019
PROJECT NAME ALLIED INTERNATIONAL EXHAUST
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE ❑
COMMENTS
ctipttiva glir nW"%T:laMi�iulG<zi7w nn
NOT COMPLETE ❑
vc4.awar ,Man.+m .aww.w uw2040,1. . , a ...W .n nrrInNWIIC
PLAN REVIEW / ROUTING SLIP
DATE 1/24/97
DEPARTMENT:
BUILDING DIVISION ❑ FIRE PREVENTION PLANNING DIVISION ❑
PUBLIC WORKS ❑ STRUCTURAL ❑ PERMIT COORDINATOR El
4
DUE DATE 1/28/97
NOT APPLICABLE ❑
TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ❑
ROUTED BY STAFF I I (If routed by staff, make copy to master file & enter Sierra.)
REVIEWERS INITIAL
I
I
APPROVALS OR CORRECTIONS: (ten days)
APPROVED n APPROVED WI CONDITIONS
REVIEWERS INITIAL 4i1 5 / f DATE h ('
CORRECTION DETERMINATION:
REVIEWERS INITIAL
C:ROUTE -F
DATE
DATE
DUE DATE
2/11/97
NOT APPROVED (attach comments) ❑
DUE DATE
APPROVED ❑ APPROVED WI CONDITIONS ❑ NOT APPROVED (attach comments) ❑
(Certification of occupancy required. )
PUBLIC WORKS
{
COMPLETE
COMMENTS '
REVIEWERS INITIAL
APPROVED 0
REVIEWERS INITIAL
C:ROUTE -F
PLAN REVIEW / ROUTING SLIP
•
ACTIVITY NUMBER D97 -0019 DATE 1/24/97
PROJECT NAME ALLIED INTERNATIONAL EXHAUST
DEPARTMENT:
BUILDING DIVISION 0
U
DETERMINATION OF COMPLETENESS: (T,Th)
REVIEWERS INITIAL
APPROVALS OR CORRECTIONS: (ten days)
CORRECTION DETERMINATION:
FIRE PREVENTION U PLANNING DIVISION
STRUCTURAL 0 PERMIT COORDINATOR 0
J
NOT COMPLETE •
TUES /THURS ROUTING: PLEASE ROUTE El NO FURTHER REVIEW REQU1REDI:1
ROUTED BY STAFF 11 (If routed by staff, make copy to master file & enter Sierra.)
DATE / -261—
I
I
APPROVED I I APPROVED W/ CONDITIONS ❑. NOT APPROVED (attach comments) fl
DATE
APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0
DATE
DUE DATE 1/28/97
NOT APPLICABLE Ej
DUE DATE 2/11/97
DUE DATE
(Certification of occupancy required,
I
ACTIVITY NUMBER D97 -0019
PLAN REVIEW / ROUTING SLIP
PROJECT NAME ALLIED INTERNATIONAL EXHAUST
DEPARTMENT:
BUILDING DIVISION FIRE PREVENTION ❑ PLANNING DIVISION ❑
PUBLIC WORKS i STRUCTURAL ❑ PERMIT COORDINATOR ❑
DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 1/28/97
COMPLETE ❑ NOT COMPLETE ❑ NOT APPLICABLE ❑
COMMENTS
TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED Lg
ROUTED BY STAFF rl (If routed by staff, make copy to master file & enter Sierra.)
REVIEWERS INITIAL ( DATE I"
APPROVALS OR CORRECTIONS: (ten days) DUE DATE 2/11/97
APPROVED n APPROVED W/ CONDITIONS ❑ . NOT APPROVED (attach comments) ❑
REVIEWERS INITIAL
CORRECTION DETERMINATION:
APPROVED I I APPROVED W/ CONDITIONS
REVIEWERS INITIAL
C:ROUTE -F
DATE
DATE
DATE 1/24/97
DUE DATE
NOT APPROVED (attach comments) ❑
(Certification of occupancy rcquired. )
I
0
v
Bre y_ 97 " ?a` r
- 1) 4 97 00 61?
SrFet. Pat 12A r - = 2 . Auto tAitit.NAir co,) . ExNiusl - rualicok L ,4
use f 1994 uric um" 22
I. ref. A14 ysiS
V : (jA) W £ zO.3e. (SoM -3)
S•(,o 2.75
r2 G Ttk�
• ThHt — eRA&eQ fRAME1 ,
R» s $ Los 44r `D4 - 0►DA&
us c 104.1 ��,i . F►ti akuc beA.Q • east)
l3k5t V . 0.3 2,1 S /6) x 3 t, Zo r.
L4sto c. A Wro I i = 3(•'' ar z { k = 704- a 4- 4- tea
isa4c_P") e
F • 9.1080
0
ft • m.163k •I` s D.2 ;2 k
544 M = 44.11 tl Z _ 44,0— (, 425'r +2115
se% R r 1.49 T = 19
G.e.m) R = 1•1 iii 14,1
�._ 1 / o x 4' /Z 144-1 LT t
7A . 0. t5
VA , 1.1.4 1 `
Loo To P
ZCBz * 4421
TIT,4- \/j4
� t1'A5 '
1, ,�r • j441: •
k °.�
EXPIRES 7/14/ 98
0.
V= 9. trig /cat.
Pc s 3, 2R k
l a -Z (3" E-w.8 Eo) p:# R*sE pLA
k\t,iskatir SPEC.ut_ I�StECP1,a
0.14 0k_. L 1.
Le-Jet. 04 Lk( !S Len cRtr1 c ,k
*Mc. BAst
f R i a• L s
6841.4
.Anc tp.1r
�• 495
73.44"
P s D,ac. c
SAArtti 14 G+1 SgWrs
344"
4. 0.9
RECEIVED •
CITY OF TUKW
JAN 2 419
LA
9 7
PERMIT CENTER
41
o.1r C73•¢a)/404.3 136.21
W LTA Q = 4Z, DS' q t 8,18 k4s:
� k • S, �p 0, 28 3et c 4 13 z 3,1o •k 7 P
�a (r sr
e( .
lust '1 Ace Ct s '
PA
Low trig
0.449"
• - y ;
sksr PLATo-s
`f. 122 K 1.0
C L)
Pr 1 191
M tool r , 3.2 14
s 3 x 3 Ye, to sA
afftet • IS.Ate PLAID M I/2 d /U- k oom, G•t.vw.4
I
z 3x4, 0,515 4 ' i . D ?S) + 2 x D, 41 S $ d, 573 a 5.4710 "'
fp z D. Sq1 k.4 Pk l *taw -Fp ,3f4/3 • 1.200 k4.
takSt 1+ M : O. 0.3-0 /z . 9.07s k
a . 15 Fy 4 4 1 3 i 3 G
gitik0 t y p.112 " ak 4 Acrlcbt. t . 10 am 69.34e)
15mA- (- E8)014), sat1mLe Scot ,°I, 3 44- k
/
S lea /lM,. 4.1 *ct s 5 1 0 pc , 127 p (¢ . o. bs,
5 L,rq L s o . 121 K /it D, S 2 9 k ` '
9, 521 I' 1" CM w ps I 44 3117 •1?.
5.Dik 611444 : (1Z.34' 2 4- 5.0 -F 2.344)27144• z 1122 Pril.
1,12 sk > 7 Pt.
USE V. m. 3 . ( t1s/,)x 31,20 /2
P s D , 038 k M'= z O.041 k
: 44- 4z 40
s.iakr . # = ky lo`
u)
4 ,1 f $2... 4 ., 4 "
.4:• t-. Or
.2
9.l86 e.L i..
P3 , o, Di" k
Nit/MVO-4 s C
C t wa.11
; ..
r F6 . 19.5+ 1—
41 Fa 4- 4 /
Fa = Ev.I ,qt to .1Y k4.:
. +3 .1- .1
dk �/ I , 35
9 704
1 -Wa0) 56•4 AO Mast Om cm_
u.. lSrklks Ate U3 404-
STD 344.1 RQA CZErr 5eis = 13. Si k
*-to *A -o Stss '!a 6, .74 a GVa:it6t4
asiN4 A 24. ado fixtry Pia o+RR ✓tnf G.,ws
Ovo 14 • 5.94 / 2 f •. Z o (1.211/2,) K 10 y r z 4 . r '
�k a 4 .
t lit O . $ ' / . 2 % ) 1 / , . 4.3o k
f ► • 6.44 IA$44' p L • 4 Fy = 3a '
Ai s S Co. to) Cie S) = K 0.8 , 0./2
44. Zit Soo . 2.oSit
k /ido • psi?"
. S8 Ix
p$ Aote 0413 . o7S
f' s 1.aok • 4.3f ks.'
1/1 $ 1.93 k" 'ix ' 23.02 ksi
r icy 3o bs-'
k 13• At's 4 ' k: k * 1.o Lys G3 I 42.
3 . i t
G kL tr) y z q/.'14 GQ,rrR.ts 47 Cfes : 34.52
r , . 1 ) $ ' ' 5 s • oo tot %I , e 0.424 4. co- 1f, 300
Fe - 19.54 kti: 4 Er /z = 25 t 4
GAGE
T
in
X
in
I
in
S
in
r
in
I
in
S
in
r
in
AREA
in
16 .060 .4189
.0893
.1 190
.6234 I .00379
.0456
.4066
.2297
14
, .075 I
.4261
.1081
.1440
.6169 , .0464
.0564
.4043
.2839
12 .105 ' .4405
.1418
.1890
.6041 .0621
.0767
.3999
.3885
10
.125 I .4551
.1706
.2275
.5914 .0764
.0960
.3956
.4878
10
9
U,
oZ
a 8
°0 7
a o 6
x
a 5
ac 4
0
o 3
z 2
1
0
20
f
H= 1 1/2
BRACING SECTION
PROPERTIES
y �-
XI+-
30 40 50 60
LENGTH IN INCHES
B= 1 1/4
krtEPARED BY
P. TINGEY
DATE
10MAY91
t
70
REVISION
NO. I DATE
aNvMI\EI ■
■
NE I N NINEES EME u
r�►� a aaa.
NE I ■M __.MME I wry\ uu.v■
111111111NEMEILIMIUMMEE
=111111 1111111111111ML
NE I ■NT I _ uaMEMV� �l
EEi l
■.n� N �����������������v�
ME I ■ __ _ . MMEM ...uaMwa
I I I
.� �n u
aaa.a. 1��a..aa.
aaaa aaaa.aa■ ■aWa
EMMEN MINEEMIESSI 10 G MOMMEMEMMUUMMill
..�5 U •
__1aROUaU. aaaaU
NM I 112M•r0�11►\
NMI 14 Gc __a��a� __vu■■
DRAWING NO.
R -3
0
80
13.3
14.6
10.6
9.31
7.98
6.65
5.32
3.99
2.66
1.33
•
VStsb
3TX
I2 -94-
US,N6 A44 F = 0.4 i rya.
oa,eo 3- Pip, IA'1T d. Ac4ts momF17 CA-PAC ay
Pii lrJAsti os . Is C I° Fr : 44 kk•
COLUmN nA -Vtg 144. 11 ASTM it 510 tog 5D I /n(
FY = So ks< 1 vni Fit : 65 ks,.'
P•s-1 t, smit e a 11/32
P4N AtEtt • IT D :/ 4 • 0. 0122 I +• ~
1 , 4
CIA RiA 1 J u
FtN I.0 F4. P'a Cot .0641.4 eriAireglArt.
P P1� s14E*4 P : .00281 x o.4t4 ,
s 1. 6Z �-- 71.4(4
N ' L. 15E0fut44. e , LM 15 oft, Loh 20 't .075 `)
p
k
P r . (11/32.) 40, DV. 6S = 1
Camp. pig; mritiac oa !.M 50 (t : 0. los ")
/3 Z) . los A 63' 2.3
US P : l.:� : � = t7z 0.84 A•ND _ Oa:14 k
Ai10 14 I.43R4.7S 0.84x 2.7.S+ .09(cx0.7S= /0. /
iv) p 13,
C6pr7Ro
)D,18K4 /3 = 13.57
totrA F S S k Col �
Be'1✓t•••+ •r+ LAI Is •r< (M t.,
P I 7 (t / L) (0.074 x : C = It 420
dr110 BC Ws Opt LM 3a AT f s t = 1,91k
i
/.:3 k AoGS Apn Lit 30
SEis MA
fi r- F,.
4 2 k . of 4S IGS.
1
r�A - (.1.42/143)03.57) - 11,8Z
LM 1 ox L wJ zo
57 14 L 3 (F : 4e" .-Nr 4s ko,
OT724L
4C /_�
B
.87
H .67 ..r_
T -I x
LM
PRIMARY COLUMN
PUNCHED
BACK -UP COLUMN
UNPUNCHED
LM
x
COLUMN SECTION
PROPERTIES
pREpARED BY
P.S.Tzngey
DRAWING NO.
R -2
DATE
16 JAN.'92
REVISION
NO.
_
DATE
BY
A
15APR'93
PST
MODEL
NH
IT:c1
B
in
X
in
I
in
Sx
in
rx
in
Iy
in
Sy
in
ry
In
AREA
In 2
LM 15
.075
3
1.625
.689
.582
.388
1.156
.205
.219
.686
.411
LM20
.075
3
3
1.435
1.023
.682
1.263
.872
.557
1.165
.618
LM30
.105
3
3
1.45
1.373
.915
1.249
1.164
.752
1.15
.859
LM20/15'
LM20 /20
'
3
3
4.625
6
2.607
2.714
1.78
2.222
1.187
T 1.481
1.231
1.268
2.577
4.701
.988
1.481
1.143
1.431
1.845
1.349
LM30/15
'
3
4.625
2.789
2.126
1.417
1.23
3.052
1.094
1.473
1.384
LM30/20
' 10 0 7S
3
6
2.951
2.568
1.712'1.262
5.45
1.788
1.838
1.590
LM30/30'
3
6
2.707
2.98
1.986
1.256
6.387
1.94
1.839
1.875
B
.87
H .67 ..r_
T -I x
LM
PRIMARY COLUMN
PUNCHED
BACK -UP COLUMN
UNPUNCHED
LM
x
Sw u...xi a: V mw�px«.liff �r < »a4iJrak �k. >�rsn
City of Tukwila
Fire Department
January 28, 1997
Fire Department Review
Control # D97 - 0019
Re: Rack at Allied International Exhaust
1165 Andover Pk W
Dear Sir:
FILE COPY
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. Storage may not be closer than 36 inches in all
directions to ceiling -hung "Space or Unit" heaters. (UFC
1109.2)
Storage may not be closer than 18 inches below
sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1)
2. In double row racks with heights of storage up to and
including 25', an average nominal 6" transverse flue space
between loads or at rack uprights shall be maintained.
(NFPA 231C 4 -3.1)
Thomas P. Keefe, Fire Chief
Maintain minimum 6" longitudinal flue space between
back to back racks. (NFPA 231C)
3. Where storage height exceeds 15 feet and ceiling
sprinklers only are installed, fire protection by one of
the following methods is required for steel building
columns located within racks: (a) one -hour fire proofing,
(b) sidewall sprinkler at the 15 foot elevation of the
column, (c) ceiling sprinkler density minimums as
determined by the Tukwila Fire Prevention Bureau. (NFPA
231C, 3 -2.3)
4. Aisles leading to required exits shall be provided
from all portions of buildings. Aisles located within an
accessible route of travel shall also comply with the
Building Code requirements for accessibility. (UFC 1204.1)
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439
: Page number
City of Tukwila
Fire Department
Contact The Tukwila Fire Prevention Bureau to witness all
required inspections and tests. (UFC 10.503) (City
Ordinance #1742)
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
• 5. Depending on the classification of the commodity being
stored and the size of the storage area, smoke vents and
curtain boards may be required by Table 81 -A of the Uniform
Fire Code. Contact the'Tukwila Fire Prevention Bureau for
further information.
6. Depending on the classification of the commodity being
stored and the storage height, in -rack sprinklers may be
required per N.F.P.A. 231C. Contact the Tukwila Fire
Prevention Bureau for further information.
7. Refrain from blocking sprinkler coverage with
shelving. NFPA•standard #13 states that any shelving or
decks in excess of 4 feet in width will require
installation of sprinklers thereunder.
8. High -piled combustible storage is combustible
materials in closely packed piles more than 12 feet in
height or combustible materials on pallets or in racks more
than 12 feet in height. For certain special- hazard
commodities such as rubber tires, plastics, some flammable
liquids, idle pallets, etc., the critical pile height may
be as low as 6 feet. (UFC article 2, sec. 209 -H)
This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188. • Phone: (200 575•4404 • Fax (200 5754439
STATE OF WASHINGTON
COUNTY OF KING
AFFCONT.DOC 5/29/96
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
CITY OF T( ✓YWILA
Permit Center
6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188
Telephone: (206) 431 -3670
ss.
k014aCS I' . ekes , states as follows:
1. I have made application for a building permit from the City of Tukwila, Washington.
H -4
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a building permit for work which is to be done by any
contractor, the City of Tukwila must verify either that the contractor is registered by the State of
Washington, or that one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby
attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I
consider the work authorized under this building permit to be exempt under No. /. , and
Will therefore not be performed by a registered contractor.
I understand that I may be waiving certain rights that I might otherwise have u der state law in any decision to
engage an unregistered contractor to perform construction
APPLICANT
Signed and sworn to before me this
a/ day of \...)C`^^
2
• 'r /.
,19
NOTARY UBLIC in and for the State of Washington,
residing at / pounty.
Name as commissioned�.ev►
My commission expires: 6/1 /�
18.27.090 Exemptions. This chapter shall not apply to:
1. An authorized representative of the States
Government, the State of Washington, or any
incorporated city, town, county, township, irrigation
district, reclamation district, or other municipal or
political corporation or subdivision of this state;
2. Officers of a court when they are acting within the
scope of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in
construction, maintenance, or development work
incidental to their own business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground
mine or mineral deposit when performed by an owner
or lessee;
5. The sale or installation of any finished products,
materials, or articles of merchandise which are not
actually fabricated into and do not become a
permanent fixed part of a structure;
6. Any construction, alteration, improvement, or repair
of personal property, except this chapter shall apply
to all mobile /manufactured housing. A
mobile /manufactured home may be installed, set up,
or repaired by the registered or legal owner, by a
contractor licensed under this chapter, or by a
mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site
or reservation under the legal jurisdiction of the
federal government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or
consuming them in the performance of, the work of
the contractor;
9. Any work or operation on one undertaking or project
by one or more contracts, the aggregate contract
price of which for labor and materials and all other
items is Tess than $500, such work, or operations
being considered as of a casual, minor, or
inconsequential nature. The exemption prescribed in
this subsection does not apply in any instance
wherein the work or construction is only a part of a
larger or major operation, whether undertaken by the
same or a different contractor, or in which a division
AFFCONT.DOC 5/29/96
of the oper n is made into contracts of amounts
Tess than $500 for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in
this subsection does not apply to a person who
advertises or puts out any sign or card or other
device which might indicate to the public that he is a
contractor, or that he is qualified to engage in the
business of contractor;
10. Any construction or operation incidental to the
construction and repair of irrigation and drainage
ditches of regularly constituted irrigation districts or
reclamation districts; or to farming, dairying,
agriculture, viticulture, horticulture, or stock or poultry
raising; or to clearing or other work.upon land in rural
districts for fire prevention purposes;. except when
any of the above work is performed by a registered
contractor;
11. An owner who contracts for a project with a
registered contractor;
12. Any person working on his own property, whether
occupied by him or not, and any person working on
his residence, whether owned by him or not but this
exemption shall not apply to any person otherwise
covered by this chapter who constructs an
improvement on his own property with the intention
and for the purpose of selling the improved property;
13. Owners of commercial properties who use their own
employees to do maintenance, repair, and alteration
work in or upon their own properties;
14. A licensed architect or civil or professional engineer
acting solely in his professional capacity, an
electrician licensed under the laws of the state of
Washington, or a plumber licensed under the laws of
the state of Washington while operating within the
boundaries of such political subdivision. The
exemption provided in this subsection is applicable
only when the licensee is operating within the scope
of his license; %•
,
15. Any person who engage On;iiip a.ctjvities�lnerein
regulated as an employee,o€ �registered contractor
with wages as his sole cofnpefismitiif; ,,,
16. Contractors on highway profeEctS,yfha,have been
prequalified as required by chaPt'er 13 of the Laws of
1961, RCW 47.28.070 with the department of
transportation to perform highway construction,
reconstruction, or maintenance work.
SPRINKLER MAIN
'PART'''
SCALE 1/J#7
25-O
-Jr
As :4 IYP
ORAa<E1 ASSY —\
ASHOTED
.375 R
RACK ELEVAlON (TYP)
SCALE: 1/4"--.1' -
19/32'0
(e."\FLOOR ANCHOR DETAIL
rgas 'FOR SPECt.
2 HOLES
CITY OF TIJOWILA
APPROVED ,
..1A0 3 0 1997
NOTES:
1. PALLET RACKS WOE MFD BY LODI METAL TECH, INC.,
OF 2. STEEL CAII IN M AI IA RACK ELOENTS CONFORMS TO
ASTM P570 GR 50 WITH Fy=13 KSI, AND Fu.65 KSI.
3. STEEL USED IN ALL BASE PAIS CONFORMS TO ASTM
A36 WITH Fy=36 Kg, AND F58 KSI.
4. MAXIMUM RACK LOADS SHALL BE 1000 LBS PER LEVEL
PER PAIR OF BEAMS.
5. CONCRETE SLAB IS GIVEN AS15" THICK, WITH fc'=. 3,000 PSI. copy 0
6. ALLOWABLE SOIL BEARING IS ;000 PSF FOR GRAVITY
LOADS, AND 1000 PSF FOR SEISMIC OR SEISMIC +
GRAVITY LOADS.
T. ALL RACK UPRIGHTS ARE MC4EL !MI5.
8. ALL RACK BEAMS ARE LE3F-404-105 OR SHORTER.
9_ BEAM-TO-COLUMN CONNECTONS UTILIZE 3-PIN BRACKETS
AND "A" TYPE WELDS.
10. ITE-DOWN ANCHORS SHALL 3 HILTI KWIK-BOLTS,
USE 1/2"0x4 1/2" BOLTS, W 3 MIN. EMBEDMENT,
ONE PER BASE PLATE. SPECIAL INSPECTION IS NOT
REQUIRED.
I ' the Plan Chcc.,..; •
ctrom and omissions c• r; cf
not authortas Violation ci
aeoptcd or of contractors
• '
tar
aPP
Data
Permit No
FILE COPY
REVISIONS
NO CHANGES SHALL BE MADE TO
THE SCOPE OF WORK WITHOUT PRIOR
APPROVAL OF TUKWILA BUILDING DIVISION.
NOTE: REVISIONS WILL REQUIRE A NEW FL,N L
A, 1, Ii7CLUDE FLAN FT