Loading...
HomeMy WebLinkAboutPermit D97-0058 - BEAR COMMUNICATIONS - PARTITION WALLCity of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 115720 -0017 Address: 15215 52 AV S Suite No: SUITE #16 Location: Category: ACOM Type: DEVPERM Zoning: 0 Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: Y Contractor License No: RMILLCI190L5 OCCUPANT BEAR COMMUNICATIONS 15215 52 AV S SUITE #16, TUKWILA WA 98188 OWNER SOUTHCENTER OFFICE PARK Phone:. (206)624 -8200 C/O COLLIERS RE SVCES, AVE S, KENT WA 98032 CONTACT PATRICIA SPANGLER Phone: 206 872 -8365 20206 72 AV S, KENT WA 98032 CONTRACTOR R MILLER CONSTRUCTION Phone: 206:583 -0238 146 THIRD AVENUE SOUTH, EDMONDS WA 98020 r**************************************************** ** ** * * * * * * * * *** ** * * * * * *** * * * *** Permit Description: REMOVE THREE EXISTING INTERIOR OFFICE DOORS AND REPLACE WITH A PARTITION WALL. e**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 2,500.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(.in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: ' End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 127.84 k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature . _ Date:5''"l I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development perm t. DEVELOPMENT PERMIT Permit No: Status: Issued: Expires: Occupancy: OFFICE UBC: 1994 Fire Protection: AUTO. FIRE ALARM East: .0 West: .0 Streams: (206) 431 -3670 D97 -0058 ISSUED 03/20/1997 09/16/1997 Date:At .4L ciate This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA .390 SOUTHCEN:TER; BOULEVARDr`SUI.TE TUKWILA :WA HINGTON 98188` TH IS.CERTIFICATE ISS UEp. R wTQb.1HE:REOUIREMENTS7,�UFF�, ECTION.307 OF. THE • :UNIFORM BUILDING GUfi,E t GERTIF.Y,II(6 ,� 9'H 4 'j At)- T E: TIME OF `-`ISSU .NCE THIS STRUCTURE W AS IN COMPLIANCE b WIT,i `THE r VARaIQUS:ORDI , .NANCE t : Oi THE CIT REGULATING- BUILDING . CONSTRUCTION ,OR Li t : ;fAND x.�,8 A CITY ` °FIR F:,'. ) .:' GORE "�f FI�R-*:;THE FOLL0w' , yr ` F%i �"i C : T4 ,a ;v . ,: i . 7T r � � ., - y, 4 , ��� .. rr xtt. ... dew 3 ;4. F1 �' ` }1 /.. •" *n QccuP Ii .BFAR w}; 4 Pe6' i t . No: G ,7.0058 • Bu17d.ing Add y ss x' 152 1 ' 5 5,2 y : AV 8 A i t ,. • �„ 5u1te . Par�ce1 # 1 1.157 , X1= 001 ? s" `t7�vner 4'.�SbUTHCENTER; OFFICE` P.AR Address 15215'.5 :AV 5 :` Pe�:mit .No G97 0058 Su i,te Tenant Status ISSUED Tv GEVPERM Applied •02/27/1997;• Parcel „'# 115721; -001.7 Issued: ':03/2071997` t* k ik` k**:* 4k- k.• F' k k k' k * kit 1t*; k *k:kkt *kk •k - k^k•k *l* le * * k *k *:k,'kk •fir'k'k ,kkA'k•k •k,,', P r mi t fond tions No ;changes ;iii l l :be made:to .the' plans ;unl`ess approve . the Architect. a'r En'gineer and •the, :.:Tur,wila.. Buildirig Givision El_ectrical'-'p the:' Washington : State Divi: .ion of Labor` °arid Industrie's ari'�i { a11,, electrical Wuxi. wi':ll b:e inspected by that :agency: (24R 66 A1,1 per mats'. inspection ;records arid. ap 11 avai table at ;the job site' pr', or' to • the st art of an'y 'con struction , - ::tThese documents • are to be maintai arid avai 1" . able 'trntiyl find i'ns'pection apps a . is granted`' ; All corns't rrto' beti d' one !i,n conformance,wit.h approved plans and r equ i rk eme.nts of the Un i,:for ~m Building Code (1994 Edit ion) -' as: amended,. • Un ;o r * Mecha Code (l99`4;Editi and Wa:hirigan : Ene;rgv ;code (1994 Edition) Va.l i d i tv vt,; Permi t The 1 ss of :a I or appr.ova l p lan% fS spec f i c:at i ans ;and ` compti;tat i ons shall . not 'be a r}� . • �tr�ed, °tp be a permitt far , o'r. an approval of,' any viola.tiont. of any: of t "he,;provisions of :..the build'ing)code `or. o : t any other ordinance of the fur isdi,ct,i,ori • No, frerm it pr�esum tc aiVe ;autho : provisions i f�it�r to violate or cancel the , O this code;g +slid f i ;4 A ,cERTIFICATE OOCUPANCY° WILL BE; REOUIREG FOR THIS • PERMI'T`. • '' R LLq ,i / • • Z 0 • Project Name/Te ant: VA ci i i" ;J O-1 VI1 t1 lC �z � CT( s Vaxe of Construction: Y 2 5 0 Site Address: , City State/Zip: Tax Parcel Number: I i 5 7 - 0017 1-5 X.15 i.2 alio S . _3 L& T�. « t t� Qkr t5" Property O ner•� e / Pliii (TacEtreKs Lt , e t4s, G) 0 S A Ca at ev.S Phone: 20G 74 &- r'v Street Address y/� h c / J � / : ._. Fax 20 #: y Ce Co a t r. ���1 ��l�- on S >^lcc_ !� Pone �i6 ,5` S - 3 -093 Street Address: ra City State /Zip: Fax #: Arch �segct: ; � Phone: Street Add s: 1 6{ y y J / C i ty State /Zip: 1f��i il lf.(/.Q -. S LR Sai '7 dIc/i Fax #: ._— Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: C' � c f a 5-PC , / I x lei P � --- rS 7o� > ' ��� - S �� f l vl �., ___ (.745,,j .Zi Fax #:._ -- (0 % O Description of work to be done: VO MOO l XlSiIfi I { o'C r3 �. 11 u)(f aY��'t� Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel 0-Office ❑ SchooUCollege /University ❑ Other Proposed use: in Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ MoteUHotel ®'Office ❑ School/College/University ❑ Other Will there be a change of use? ❑ yes ®'-no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 171-no Existing fire protection features: ❑ sprinklers automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: pct (G r) existing Area of Construction: (sq. ft.) 7 Gso Will there be storage of flammable /combustible hazardous material in the building? ❑ yes at Attach list of materials and stora•e location on so•arate 8 1/2 X 11 •a• orindicatin. •uantities & Material Safet Data Sheets CITY OF TrWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. CTPLRMIT.DOC 1/29/97 APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp II Size(s): Est. quantity: gal ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date applicct on accepted: ., ,--_9 Date application expires: C (7 PLEASE SIGN BACK OF APPLICATION FORM Prol.ct Num rr Permit Numbers ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only Schedule: Application taken by: (initials) BUILDING OWfyER OR AUTHOf71,ZED AGENT: Signature ' ; , zz c /�� .< . 1../ j Date: A ._ �__ (( Print name;�l I': (�t � / . / /7C Ai- i' `� Phone: l), 1/` , (, Fax #: �� 5 -- Address S.C. 7.� 11 (7 , a t , r , .. r ,1 City /State /Zip 4/1 �� �' J ' ALL COMMERCIAUMULTI -FA Y TENANT IMPROVEMENT /ALT TION PERMIT APPLICATIONS MUS BE SUBMITTED WITH THE FOLL # ING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Q Complete Legal Description a ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). �•y Four (4) sets of working drawings (five(5) sets for structural work), which include : CI 12' Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11 Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Tr F loor plan: show location of tenant space with proposed use of each room labeled ❑ O verall building floor plan with adjacent tenant use; identify tenant space use and location of storage of �.,/ any hazardous materials; dimensions of proposed tenant space. ❑ L�J Vicinity Map showing location of site Er ❑ , Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of ,...,,/ rack. Structural calculations are required for rack storage eight feet and over. ❑ LJ Indicate proposed construction of tenant space or addition and walls being demolished ❑ 0` Construction details ❑' ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. 0 ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. El ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). a ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. 0 El Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTl'LRMIT.D(.)C 1/29/97 P •'ect: Type of inspe on: A.dress: I�IS Lj2 AV S Date called: 1 4- I R� Special instructions: 1 a Date wanted: ++ ,, �m/. Requester: L-Okl iq i E. Phone No.: 5 g 3 , X23 �ata:rR. l INSPECTION RECORD I Retain a copy with permit INSPECTION .34-- CITY OF TUKWILA BUILDING?DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: Skri Ia�Bis AMA► i' :• 1a�£ r'. SU�dADi�ir�i4 ` 'l(zat�ac?�o- " S�!lVkr:•�f: 5 � : �� % <`r� Date: Corrections required prior to approval. L a- (206) 431 -3670 Inspector: /' ■ ` ���� L $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IV Date: bixit4w wi. lx41.4. Project: • , • . : . • •.,..‘" .• C. 14 , > • 07 7c/h/tga4 p of inspection: ,.....■ k , . / • /-* . o nt?/ i Address:. 5-SZA'cl At Da e called: .• ... 5) • 3-3/-,7. Special inst ions: - . . ' .'• . •:.• ''. : S ' ; Z' ' ' / • - . . . • • . , . . .. Date wanted: i / i • P.m. Requester:46 _ .,. . Phone No .......• • —. L 1` ? 6.90. I 1 COMMENTS: Inspector: I Receipt No.: 0 INSPECTION RECORD Retain a copy with permit F 2; ( E INSPECTION NO. CITY OF TUKVVILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206) 431-3670 Corrections required prior to approval. Date: $42.00 REINSPECTI N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. Date: *All**** CITY OF TUKWILA. WA TRANSMIT' 1 k i***• **** TRANSMIT Number: R9700545 Amount 127.84 02/27/97 11:40 Payment Method. CHECK Notltiom. P SPANGLER Init: KOP .. - . Permit No D97-0058 Type: DEVPERM DEVELOPMENT PERMIT Parcel No. 115720-0017 Site Address: 15215 52 AV S ..... Total Fees: 127.84 This Payment 127.84 Total ALL Pmts: 127.84 Balance: .00 .4.4*************A***A**,x4****t******** Account Code Deticription Amount . 000/322.100 BUILDING - NONRES 74 75 000/345.830 PLAN CHECK - NONRES 48.59 000/386.904 STAlE BUILDING SURCHARGE 4.50 5)26 02/28 9717 TOTAL 127.84 REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: C:ROUTE -F Fmi Ccat/ CDP1 PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D DATE �- 7 PROJECT NAME f J Corr h C.f DEPARTMENT: BUILDING DIVISION fr FIRE 4ENTION El P IVISION a PUBLIC � WORKS 0 STRUCTURAL El PE COORDINATOR • 1 4 DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE COMPLETE n NOT COMPLETE E NOT APPLICABLE 0 COMMENTS TUES /THURS ROUTING: PLEASE ROUTE NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) DATE DUE DATE 3' 51.97 APPROVED El APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) 0 DATE l APPROVED El APPROVED W/ CONDITIONS ID NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE DUE DATE (Certificadoa of occupancy required. ) DUE DATE 3.3 m , NOT APPROVED (attach comments) 0 • DUE DATE NOT APPROVED (attach comments) Q (Cerdfiadon of occupancy required. ) REVIEWERS INITIAL CORRECTION DETERMINATION: C:ROUTE -F DATE REVIEWERS INITIAL DATE PcrrnE Cooed COPS PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER OOS g DATE Z • Z7 q7 PROJECT NAME mar Comm uni cations DEPARTMENT: BUILDING DIVISION FIRE PREVENTION p PLANNING DIVISION PUBLIC WORKS UG URAL' P RMIT COORDINATOR' j13 Ia- DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE p COMMENTS DUE DATE 3' Li- q7 NOT APPLICABLE ❑ TUES /THURS ROUTING: PLEASE ROUTE p NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF p (If routed by staff, make copy to master file & enter Sierra.) I I APPROVALS OR CORRECTIONS: (ten days) DUE DATE 3-I c/• '77 APPROVED p APPROVED W/ CONDITIONS NOT APPROVED (attach comments) p °IC E� r (T-1 1 00 --e?'1-& ena1leot , 1- -Pc -ed (n1Ccrd , L I) l qq APPROVED p APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE DUE DATE (Certification of occupancy required. . !).: PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER bc1 $ DATE Z • Z7. 97 PROJECT NAME Zear Con'Y 1 ur11 cations DEPARTMENT: BUILDING DIVISION a FIRE PREVENTION ❑ PUBLIC WORKS ❑ STRUCTURAL ❑ DETERMINATION OF COMPLETENESS: (T,Th) ex-r-(-1- TUES /THURS ROUTING: PLEASE ROUTE El ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) I v p DATE APPROVALS OR CORRECTIONS: (tea days) APPROVED ❑ APPROVED W/ CONDITIONS ❑ CORRECTION DETERMINATION: DATE REVIEWERS INITIAL DATE PLANNING DIVISION PERMIT COORDINATOR ❑❑ DUE DATE 3- 4 1.97 NOT APPLICABLE ❑ l'Cd te Dcz NO FURTHER REVIEW REQUIRED ❑ I I DUE DATE I f • • 9 7 NOT APPROVED (attach comments) [f✓ DUE DATE APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Certification of occupancy required. $ ' PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER bcri 003 p DATE Z.Z7. PROJECT NAME Boar [.ornmunica DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION II PLANNING DIVISION ❑ PUBLIC WORKS ❑ STRUCTURAL ❑ PERMIT COORDINATOR ❑ DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 3 • 9 7 COMPLETE ❑ NOT COMPLETE ❑ NOT APPLICABLE ❑ COMMENTS TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL 44, 52/ DATE 3 - I? I 1 APPROVALS OR CORRECTIONS: (ten days) APPROVED ❑ APPROVED WI CONDITIONS ❑ REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED ❑ DATE APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ REVIEWERS INITIAL DATE C:ROUTE -F DUE DATE 3!7 NOT APPROVED (attach comments) ❑ DUE DATE (Cenificadon of occupancy required. ) NOT COMPLETE ❑ • NOT APPLICABLE ❑ DATE 73 f q/ 17 DUE DATE DUE DATE 34./17•.q7 (Ccnificadoa of occupancy required. + COMMENTS " REVIEWERS INITIAL REVIEWERS INITIAL PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D91 DAM 2.27 4? PROJECT NAME DEPARTMENT: BUILDING DMSION [J FIRE PREVENTION p PLANNING DIVISION p PUBLIC WORKS • STRUCTURAL p PERMIT COORDINATOR ❑ DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 3- 14.97 COMPLETE NOT COMPLETE p TUES /TSURS ROUTING: PLEASE ROUTE p NO FURTHER REVIEW REQUIRED I ROUTED BY STAFF p (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: DATE DATE J - 1 ~ l� DUE DATE 3 I • q7 APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) p APPROVED ( I APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE C:ROUTE -F NOT APPLICABLE p DUE DATE (Certification of occupancy required. ) � This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on 'your drawings. I have enclosed review comments from the Building Division. At this time the Fire Department, Planning Division and the Public Works Department have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. FILE COPY City of Tukwila John W. Rants, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 43I 3670 • Fax (206) 4313665 SUBJECT: CORRECTION LETTER #1 Development Permit Application Number D97 -0058 Bear Communications 15215 52 Av S #16 ' •, • . `', • nuiLDINc DATE: 3/10/97 PROJECT NAME: Bear Communications PLAN CHECK NO D97-0058 Plan Reviewer: ' 1. The floor plan resulting from the proposed tenant improvements is the record document for the certificate of occupancy for Bear Communications. Consequently, :' additional information is required to be documented on this plan as follows: a) Identify the "Bear Communications" tenant space on the plans. b). Identify the use of all rooms, including the adjacent tenant space that will be created as the result of this tenant improvement. • . „ c) .Provide a typical detail for construction of the listed "Building Standard" partition.. Contact Bob Benedicto at (206) 431-3670, if you have any questions regarding the following comments: d) Indicate the size of the "Building Standard" door #1. • f• Permit Cover Sheet Bear Communications, Inc. 15215 52nd Avenue South, Suite 16 Seattle, WA 98188 Owner. The Manufacturers Life Ins Co USA Phone (206) 872-4680 c/o Colliers Real Estate Services 20206 72nd Avenue South • :" Kent, WA 98032 Contact: Patricia Spangler Tax I.D. Number: 115720-0017 Contractor: R. Miller Construction, Inc. RMILLCI190L5 146 3rd Avenue South Edmonds, WA 98020 Description of Work: Remove 3 existing office doors and enclose with partition • wall.. Construction Cost: $2,500 RECEIVED CITY OF TUKWILA FEB 2 7 1997 PERMIT CENTER ,VICINITY MAP LEGAL DESCRIPTION Parcel No. B of Short Plat No. 79 -32 -SS Recording No 791205 -0555, and being a short plat ol: That portion of Tract 1 of Brookvale Garden Tracts, as per plat recorded in Volume 10 of Plats, on page 47, records of King County, lying Westerly of 52nd Ave, South as condemned hi King County Superior Court Case No. 596231: EXCEPT the North 30 feet of South 152nd Street adjoining, vacated by the City of Tukwila by Ordinance No. 502 dated December 4, 1967 and recorded under Recording No. 6296201: AND EXCEPT the West 20.00 feet there of conveyed to King County for road purposes under Recording No. 4011953: AND EXCEPT the South 51.00 feet there of Situated in the County of KIng,State of Washington. to at tU NOT TO SCALE RECEIVED CITY OF TUKWILA FEB 2 71997 PERMIT CENTER DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A State of Washington ss County of Snohomish STATE OF WASHINGTON RECEIVED JUN 1 9 1996 • fi..Miller Construction, Inc. /T. AgeoLA of "3 42ec_h , On this day personally appeared before me 441-5 iJ •GiV n my hapd and_official seal this4q77/ day )91 No Puplic in for the State of Washington, d resding at 1 fri) l e) License # 7_64, -0/ Expiration Date OZ iqq & • Representative of R. Miller Construction Co., Inc. F1325-052-000 (3-92) The above is a photocopy of the original Ccntractor's License, as sighted by by the undersigned, for R. Miller Construction Co. Inc. Project Info PmieaAadr,' D'te 1-14-111- 15 -- S2 u0 AVE. SevrN , ¶ vITE IL Po Building Department use 1NKWIL4 WA gear, Applicant Name: ' JIM 'guar-if-LS Applicant Address: \Ail *TM Avb 5 VIM t2- to Applicant P lane: 'Lelw)SQ}• -4. GENERAL NOTES 1. Contractor to comply with the current - general conditions', and building standards as provided by the building owner. 2. Contractor shall be responsible for providing all work and materials in accordance with the latest local Building Codes and Ordinances. 3. Contractor shall verify all field dimensions and conditions and shag report any conflicts or questions for resolution before proceeding with the work. DO NOT SCALE THE DRAWINGS. 4. Subject to the terms of the Lease, the Landlord shall supply and install all Work shown, caged for. or implied on the Construction Documents unless otherwise noted. 5. The use of word 'Provide shall always mean "furnish and install. connect. or secure as required. 6. All materials and equipment shag be installed in strict accordance with manufacturers written instructions and trade associates accepted standards. 7. Contractor shall provide a written construction schedule. This schedule shall include delivery lead times of construction items, and start and completion dates of each phase. The Contractor shall update and provide such schedule on a bi- weekly basis. 8. Where no building standards exist for materials called out as "18 /S) building standard" on the Construction Documents. the Contractor shag so advise within ten tot days of the Contractor's receipt of the Construction Documents so that the Designer may make alternate selections. 9. Every exit door shall be operable from the inside without the use of a key or any special knowledge or effort. 10. Any decorations used shall be non - combustible or flameproof in an approved manner. 11. All electrical. plumbing and mechanical material installations shall comply with the building shell standard specifications. 12. Work must be scheduled with the building management to avoid disruption to the tenants. 13. Access to and from the project site, special conditions. noisy work. timing of work. interning. of mechanical and electrical services, relocation of exiting equipment, casework, fixtures. Wags, etc., must be coordinated with the building management. 14. :;oniractor shall verify all requirements of exact size and quantity of equipment furnished by the tenant, including requirements for mechanical and electrical services. and be responsible for all rough in connections. 15. Adequate clean -up, protection and placement of any ceiling tiles and /or other disruption to the adjacent tenant improvements must be replaced before business hours of that tenant in order that the occupant will not be inconvenienced in the normal continuation of their office hours. 16. Each sub- yonbactor is responsible for any damage to adjacent work and shall repair said damage at their own expense. 17. Schedule the use of the elevator with Biding Management. 18. Contractor shall provide the Balding Management with one (1) copy of "as- built" drawings. 19. All materials to be new unless noted otherwise. 20. Patch all disturbed and/or damaged areas as required to accomplish new work and as required for finished appearance. 21. Provide all necessary backing. blocking. and framing for light fixtures, electrical fixtures, casework and all other items requiring the same. 21 Contractor to provide all fire /emergency systems as required by all applicable codes. Free /emergency systems include but are not limited to sprinkler modifications. fire extinguishers, audible alarms. sprinklers. smoke and heat detectors, and exit signs. 23. All paint and finish material colors shall match designer's control samples and require designees approval prior to installation. 24. Contractor shag t arnish shop drawings for approval on cabinetwork. millwork and any other special items requiring custom shop fabrication work. Submit to designer two I21 copies for approval. 25. Contractor shag provide plastic sheeting or other appropriate barrier to control dust and debris such that it does not affect areas outside the area of work. 26. Mechanical 8 Electrical to be design build under separate permit. SPECIFICATIONS The Parkridge Building - SUITE 16 DIVISION I - GENERAL CONDITIONS 01010 SUMMARY OF WORK 1 General description of project: non - structural interior tenant improvements of a commercial office suite on the second floor of the Parkridge Building. 2. Work not included: Contractor shall provide the following items described in the specifications and space plan attachment except for the items indicated - N.IC" (not in contract), telephone and data cables, fixtures, equipment and kitchen appliances. MOON 1 I - SITE WORK 02050 - DEMOLITION t Furnish all labor an materials and equipment as required to complete the demolition and removal of all items located in the construction areas. 2. Upon completion of all demolition work all areas shall be left broom clean. 3. During the removal or any environmentally hazardous materials protection guidelines should be strictly followed by code or local governing authority. 4. All existing construction items that interfere with the consfuction per the construction documents shall be removed, relocated. or kept flush in the ceiling. wall. or floor as required. 5. All damaged areas shall be patched as required and finished to match existing adjacent areas or as specified to provide a "like new finish ". Project Description - I El New Building ❑ Addition Alteration Exceptions (check appmprale bast LIGHTING SUMMARY DIVISION VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 ROUGH CARPENTRY 1, Provide all new partitions as shown on the Construction Documents. 2. Walls shown aligned with base building structure shall be flush and smooth with base building structure, unless otherwise noted. 3. Seismic bracing: provide seismic bracing as required per the latest building codes Inew construction only) to the partition heads and ceiling grid. 4. Framing studs: Metal studs 25 gauge, 2 -1/2" galvanized steel with sheet metal backing within all walls receiving casework (cabinets, bookshelves. etc.) 5. Provide as required one 4' x 8' x 3/4' thick fireproof grade plywood panel mounted for Tenant's voice and data equipment and wiring as shown on the Construction Documents or as directed by the tenant. 08710 FINISH HARDWARE 1. Finish hardware shall match building standard. 2. Hardware to comply with the current accessibility standards. Style per the owner's direction. 3. Provide silencers on all door frames. All door stops to be wall mounted unless noted otherwise. 4. All locksets shall conform to the building's grand master keying system. Provide two 12) keys for each lock and two 12) master keys for the suite. All keys to be tagged with room numbers. DIVISION IX - FINISHES 09250 - WALL SYSTEM 1. "Wall Surfaces" mean all vertical surfaces including columns where exposed. convector or radiator enclosures, fascias, returns, plywood backboards, etc. 2. 5/8' type "X" gypsum wall board with all drywall accessories. 3. All corners to have corner L metal. 4. All partition heads to have F molding. 5. Prior to receiving finish, all surfaces shall be properly prepared as required to receive final finishing as specified. 09530 ACOUSTICAL TREATMENT 1. Provide sound ball insulation between framing studs in all new construction. 2. Demising wall construction and other additionally noted rooms to have sound bait insulation between framing studs and two feet of insulation on either side of the partition head, above ceiling grid. 09680 CARPET 1. Provide new carpel per the finish schedule. 2. Carpet to be Installed over manufacturer's specified pad. 3. Provide seaming diagram for Designer's review and approval. 4. Verify condttinn of concrete underlay prior to installation of carpet. Patch, level and prepare with cementilious':underlaymenl per manufacturers written instructions to floors receiving carpet if condition of concrete underlay warrants such action. 5. Upon completion all work shall be cleaned and all spots of adhesive and surface stains removed. 09900 PAINTING 1. Paint all dry wall surfaces throughout with two 121 coats S/S latex paint with satin finish. Provide one (1) paint color, refer to finish schedule. Prime all surfaces, unless otherwise noted. 2. Paint for the light surfaces to .conform with the requirements of the "Architectural Specifications Manual" IAWS1 for paint systems. Latex paint: AWS System 3 -8 "custom" 12 coati grade light color paint finish on gypsum board surfaces. 3. Upon completion of work, remove excess paint, stain varnish, adhesive, caulk, etc. from all other surfaces that were not specified to receive same. 4. Touch -up and patch surfaces as required after the completion of work by other trades. 5. All doors shall be finished with two 121 coats of clear satin finish polyurethane varnish. DIVISION XV - MECHANICAL 1994 Washinaton State Nonresidential Enerav Code Compliance Form cv LTG-SUM Lighting Summa Compliance Option ❑ pmtoytae ❑ Lighting Power Alb ante ❑ Syslernz Analysis (See DualK Opp Ch JOct Inver, Indicate Prescriptive }IPA spaces Army on plans.) Y1.No Barges are being made tome lighting ❑ Less than W % of the roiures are new, and irsaikd N'aMirg wetage o t beug nv®sed 15500 FIRE PROTECTION 1. Fire protection system per .building standard and Local Regulations and Ordinances. 2. Provide all emergency lighiing,xexit signs, fire alarm speakers, strobes and bells as required by code. Design and install the same in compliance with the Americans with Disabilities Act. 3. Provide lire extinguishers etc. as required by applicable local codes and laws. 4. Fire extinguishers shall be installed in recessed cabinets. 5. Relocate sprinklers as required to maintain design intent and code requirements. 15800 FINAL. 1. Building Standard H.V.A.C. systems with all materials, labor and accessories for complete operation of the system. Balancing of the H.V.A.C. system to be done by contractor. 2. Design of mechanical to be prepared under a separate permit as a design build project. AREA OF WORK CONSTRUCTION LEGEND O NEW OR RELOCATED B/S WOOD DOOR 3 -0 X .Si9 WJSTYLE OR FINISH TO MATCH EXISTIN . e NEW B/S FULL- HEIGHT PARTITION. - - REMOVE EXSTING DOORS = = DEMO EXISTING WALL EY*-005 L lt=rh 1 = 71 =i 7 =T-I=T= UP OFFICE OFFICE i_____ SUITE 12 (VACANT) FLOOR PLAN - FIRST FLOOR SUITE 18 (VACANT) ALIGN OFFICE GENERAL NOTES NO STRUCTURAL CHANGES ARE TO OCCUR IN DESIGNATED AREA OF WORK. NO CHANGES TO THE CEIWNG GRID ARE TO OCCUR IN DESIGNATED WORK AREA. ALIGN ALL TRIM AND WOOD FINISH TO MATCH EXISTING. SUITE 10 (VACANT) FINISHES SUITE 16 BEAR COMMUNICATION NEW CARPET TO BE INSTALLED THROUGHOUT DESIGNATED AREA OF WORK. CARPET TO BE J&J INDUSTRIES. VERIFY WITH TENANT FOR SPECIFIC COLOR. NEW PAINT TO BE APPLIED THROUGHOUT DESIGNATED AREA OF WORK. PAINT TO BE BENJAMIN MOORE - ATRIUM WHITE. RUBBER BASE TO BE 4 ROPPE - SLATE. O 1 /8' = 1' -0" PROJECT CONTACTS Space Planner Burgess Design 1411 Fourth Avenue, Suite 1206 Seattle, WA 98101 587 -7120 phone 587 -7122 fax Jim Burgess Owner Agent Colliers 20206 72nd Avenue South Kent, WA 98032: 872 -4680 phone 872 -8365 fax Pat Spangler Tenant Bear Communication 15215 - 52nd Avenue South, Suite 16 Tukwila, WA. 98188 VICINITY MAP REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OF TUKWILA BUILDING DIVISION. NOTE REVISIONS WILL REQUIRE A NEW PLAN SUBMITTAL AND MAY INCLUDE ADDmONAL PLAN REVIEW FEES. AGENCY NOTES Area of Construction Constructon type Occupancy Address: LATERAL BRACING OF PARTITION HEAD TO STRUCTURE -14) 12 GA WIRES @ B' O.C. ALONG PARTITION TO CONFORM TO ICBO REPORT 4070 1/8' FOAM TAPE WOOD SPACER 2 -1/2' HTL, STUD 25GA @ 24' DC 2 -1/2' SOUND INSULATION (FIBERGLASS) - nn011UNRUIIUUIUNIUI I "l 1111111111111111111111111111111f- I�� 45 O PARTITION BRACING 1 • Scale: N.T.S. approx. 1,387 square feel Type V -N 15215 - 52nd Ave. South Tukwil WA 98188 LEGAL DESCRIPTION Parcel No. B of Short Plat No. 79 -32 -SS Recording No. 791205 -0555, and being a short plat of: That portion of Tract 1 of Brookvale Garden Tracts, as per plat recorded in Volume 10 of Plats, on page 47, records of King County, lying Westerly of 52nd Ave, South as condemned in King County Superior Court Case No. 596231: EXCEPT the North 30 feet of South 152nd Street adjoining, vacated by the City of Tukwila by Ordinance No. 502 dated December 4, 1967 and recorded under Recording No. 6296201: AND EXCEPT the West 20.00 feet (here of conveyed to King County for road purposes under Recording No. 4011953: AND EXCEPT the South 51.00 feel there of Situated In the County of King,State of Washington. Date R2 SELF TAPPI B/S F -MOLT 5/8' G.W.B. TYPE N.T.S. FILE COPY I Unde-:_AJ t::ot the Plan Check sal:; = l io oROr3 and omissions and piano does not authorke Os Violation of c::7 ad code or OIL NNW of contractors /1' n Pem,O No J c ti - 00v` THESE DRAWINGS HAVE BEEN CREATED BASED ON PREVIOUS DRAWINGS BY OTHERS. THESE DRAWINGS AND ANY RELATED MEASUREMENTS ARE UNCONFIRMED AND MUST BE FIELD VERIFIED. SEPARATE PERMIT REQ IRED FOR: G MECHANICAL ® ELECTRICAL ❑ PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION CITY Of TUKWILA APPROVED MAR 1 8 1997 AS NOIEU4 BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 1 7 1997 PERMIT CENTER PROJECT: DATE: FILE: DRAWN: CHECKED: JB 9724 01.29.97 JML TA