Loading...
HomeMy WebLinkAboutPermit D97-0077 - CB RIVERVIEW PLAZA #2 - FRONT ENTRY DOORS• City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Contractor License No: SHOREGA099CJ Signature:__ Print Name:_ 252304 -9077 16000 CHRISTENSEN RD ACOM DEVPERM TUC 001 North: TUKWILA DEVELOPMENT PERMIT Fire .0 South: .0 East: Sewer: TUKWILA Slopes: N Permit No: Status: Issued: Expires: Occupancy: UBC: Protection: .0 West: Streams: (206) 431 -3670 D97 -0077 ISSUED 03/17/1997 09/13/1997 OFFICE 1994 SPRINKLERS .0 OCCUPANT CB RIVERVIEW PLAZA #2 16000 CHRISTENSEN RD, TUKWILA, WA 98188 OWNER JOHN HANCOCK MUTUAL LIFE Phone: (206)431 -8336 16040 CHRISTENSEN RD #214,,TUKWILA WA 98188 CONTRACTOR SHOREWOOD GLASS & AUTO Phone: 206 244 -7512 2639 SW 110TH, SEATTLE, WA 98146 CONTACT CHUCK MAHLUM Phone: 206 241 -5258 16000 CHRISTENSEN RD #101, TUKWILA, WA 98188 k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: REWORK FRONT ENTRY DOORS IN BUILDING. k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 8;000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: No: Size(in): .00 Flood Control Zone: Hauling: Start Time: End Time: Land Altering: Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start Time: End Time: Sanitary Side Sewer: No: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: Public: k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 141.75 k***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature ,j : -- _ -- y _a7 U "__ Date: 3 ) I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development per it. � I Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Addres's 1.6000 `'.CHRISTENSE'N `.RD Permit No D97 0077 suite T 4na n. t S TssuED T ype DEVPERM Appli 03/11 "/199 Parcel • # 252304 9077 :.Issued 03/17/19 * k le,* k #F k,'k ***** k*01 *•k.'k *'k *.** k k* k k`•k.k* k k *:k** k k A* k: *** k•k'-i k A ** k *:•k.'k ** k A •k k* k k* k k *.A ** P ermi t : Cond;i t ions 1 , Na" c 1 1 : ; be': made:" to the :plans un less ;approved by the • Tukwl.la Building Division • 2. Al pe i re c$r approve plans shall be a vail a ble at ' th:e iob's)i t pr'i` 'to, the start` .of any con str uct.ion These .d cu'me ; , are . ma` ii:ii, i;n"ed and ,avail gabl u ti n 1, f i na� ln^ 3Anspe+ t.iobn .appr oval is 9!r n ated,:'' ., A construet;1:on to be d . ni :,contorrmance'wi th ap proved pl and , re .qu i r eme`nts ;, of the Unif Bu , Code : (1:994 Ed ition) as.: amended,' Uniform: Me 'chan.i'cal Cadet. +(1994 Edi..t,ion) , an dWashington ;State En e: gy :Cod (1994 Edi tion ) 4' V a.l id t ' y rbf `Permit • { =The i ss;uari+ a ,o,f, 61:.. perms t or approv a ,l '.o p l ans� sp i ca n t ios, a nd fr compu t atti,on s h l l� s a' no " ;.be c strued7,fto be a.;per.mit. for, o an_aparoval oft anv :violatfp of ariu� ~of the.:pr ovislon of 'th,e :.building ,code or'of �an,y ' other ordinance ut. the aurisdict';ion l', • No, permit presuming i gsv'eY auth r,i otv violate or, cancel 1 the prov isions of this; cade sha 1 1'''be l ` "va s d �.;. Ow / : ' . ** -*414 • CITY OF TUKWILA : WA ' ' Dr ....,-,,,-,-) i TRANSMIT • ,,. ,.. . ;TRAWSMIT:Nuei3er: .R9700556 Amount: 141.75 03/11/97 1032 Payment IMethod : CHECK ' Notation RIVERVIEW Pl...AZA In it: SLB -.....-.......--- . .‘ .,..., Permit No L,097-0077 Type: ,DEVPERM DEVELOPMENT PERMIT Parcel .No : 252304-9077 : , - • Site 'Addresi: 16000 CHRISTENSE:N RD , '., • ' s • . ' " • Total Fees: 141.75 This • Payment - 141.75 Total ALL Pints: 141.75 , , • .Balance: :' ' • **1v****** Account Code Descri pt on Amount 000/322.100 BUILDING - NONRES 137.25 000/386.904 STATE BUILDING SURCHARGE 4.50 3447 01112 7717 TOTAL 499.09 Project: /el th. Type of insp tion: r ....— Ad 6Az7 ci, , lig/ Date called: Special instructions: 'bate wanted: cti Requester: Phone No.: • INSPECTION RECVD Retain a copy with PL,nit INSPECTISN NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ......ntesiceurmAsessmarAmMIMOMESMien PERMIT NO. -(206)-431-3670 Approved per applicable codes. I I Corrections required prior to approval. Inspector Date: Af' A Le 1' $42. p EE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • Project, Jame /Tenant: / a Value of Construction: Site Address: i r City Sta�te /Zi : /� i (-4/4/5 eA : 7/4 • .. 6 /C. A? /.:.");i‘.4 7U /8 Tax Parcel Number. (9 5 "? ' ,e./ —1077 —0 _ Phone: c2 / - 5 Prop rty Owne : (�,6 ve r /c) 4 4- Street Address: City ,State/Zip: le5;l•' 7) (..�//..y.`, r SF' > Lo ( :f ; / c' l 7172, „,,,)/0 ys Fax #: Contractor: <---• / , . - . n o C7 /A!.': `. '- 47Tr.., Phone: .� o r 4/V/ - /S -4 / Z, _ Street Address: , ( n City State /Zip: 6:77 , 1A //( `. L.) /,J,_ /6/ Fax #: 0 e /3 -- .218 Architect: /1 0 Phone: ._ Street Address: City State/Zip: Fax #: Engineer: 4 „ Phone: Street Address: City State /Zip: Fax #: .1- Contact rrson: L-XV t ,'t»- - Phone: !! c 7// /” e Stg Street Address; City S te2ip: 4" (> )51A) / '6 t) -fi- // 7T/ . ,J,�r p Fax #: , c `//- 7 /Z Description of work to be done: / ' a .J :� " /<):vJ- i " !/,i';,.rf 4 ,' _/;) '- (.1 = � . I Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital in Church ❑ Manufacturing ❑ MoteUHotel 0 Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital Cl Church to Manufacturing ❑MoteUHotel )TTOffice ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 171 no Existing fire protection features: in sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: `7`Z', 7 existing Area of Construction: (sq. ft.) u 0,7c) Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 in the building? ❑ yes no X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUi WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp tt Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. 'Date application accepted: cTPERMI'r.1.)OC 1 /29/97 3-\ C Date application expires: Application ,laken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM BUILDING OW R OR AUTHORIZED AGENT: Signature: // f �. /,/ Date: �J /l Print nam c. , J �� I�r, c_ /ice r j f PhoneL7, Fax #: 75 - i „. ; ,: : C��/` Address ,, 1 <' City /State /Zi - Z c�,,/ C ALL COMMERCIAUMULTI-FA Y TENANT IMPROVEMENT/ALTISATION PERMIT APPLICATIONS MUM SUBMITTED WITH THE FOLL ING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER D. ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN Y BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ r Complete Legal Description ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : d ❑ Site Plan (including existing fire hydrant location(s) d d O 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). Floor plan: show location of tenant space with proposed use of each room labeled Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. Vicinity Map showing location of site Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. Indicate proposed construction of tenant space or addition and walls being demolished Construction details Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. SEPA Checklist - if intensification of use (check with Planning Department for thresholds). Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPf1MIT.DOC 1/29/97 fl, : .+t•.Y.s. - r; Y.v Jt:.I 1 `1h4MM`.uYl }mmr'.fP�MYR44`flt,. M�� MR. Wf�v�aia�P, Nrt`) M^ W. NeM�HY. siV: itMami+ Mwnv+ UbrrY. a1N✓ <�Ym'.xstYfMlhyiA!AJnMfANt/MbV4 MgGMri+ ACTIVITY NUMBER D97 -0077 DATE 3/11/97 PROJECT NAME CB RIVERVIEW PLAZA #2 DEPARTMENT: �ING DIVISION FIR PREVENTION PLANNING DIVISION 0 PI PUBLIC STIR CTtJ AL PERMIT COORDINATOR 1 • AJ 4 DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 3/13/97 COMPLETE gi NOT COMPLETE U NOT APPLICABLE 0 COMMENTS TUES /THURS ROUTING: PLEASE ROUTE U NO FURTHER REVIEW REQUIRED Ei ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED El APPROVED W/ CONDITIONS El REVIEWERS INITIAL ?e C.d'ircor copy PLAN REVIEW / ROUTING SLIP CORRECTION DETERMINATION: REVIEWERS INITIAL APPROVED El APPROVED W/ CONDITIONS NOT APPROVED (attach comments) 0 C:ROUTE -F DATE DATE DATE DUE DATE 3/27/97 NOT APPROVED (attach comments) Q DUE DATE (Certification of occupancy required. ) ACTIVITY NUMBER D97 -0077 DATE 3/11/97 PROJECT NAME CB RIVERVIEW PLAZA #2 DEPARTMENT: BUILDING DIVISION r PUBLIC WORKS 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED C✓ ROUTED BY STAFF p (If routed by staff, make copy to master file & enter Sierra.) DATE 3/ 3/97 REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED E 1, REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP NOT COMPLETE p NOT APPLICABLE DUEDATE 3/27/97 APPROVED W/ CONDITIONS C NOT APPROVED (attach comments) p CORRECTION DETERMINATION: FIRE PREVENTION p PLANNING DIVISION STRUCTURAL PERMIT COORDINATOR p DATE 3/ 3 i c7 jj DATE DUEDATE 3/13/97 DUE DATE APPROVED p APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) ❑ (Certification of occupancy required. ) MITOM 84AM x °a nayy `: `';':: .at;.+:l.i:i :+: "n:"%�b. ,i'w ?:Tiic ^�1 '.,Y:+''vl)a 'M.'t`iJr1Nti•�b!!4K- }a.{'?IaV, in�9l :YbnSb'v1.W,�r:2:V`%!Y'V!t•1•lf iM1V.:! e7(, q. YTI '.YW...K:YRGSL'&JR4k{.h"J!6/nY R'ITl.OAki07 / AMr >:.A•*21 ['W:� '1ia14'{ itqk }Y}j' { (�,5 ;{ (` '> s1Ni`11v4i.'i!1A.9T(tV�4 uW' i.T4.A ' �/�' S: ACTIVITY NUMBER PROJECT NAME CB RIVERVIEW PLAZA #2 DEPARTMENT: BUILDING DIVISION i-1 PUBLIC WORKS 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n COMMENTS ' TUES /THURS ROUTING: PLEASE ROUTE E. NO FURTHER REVIEW REQUIRED 2' ROUTED BY STAFF [] (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F L PLAN REVIEW / ROUTING SLIP D97 -0077 NOT COMPLETE '74,6 APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: APPROVED ❑ APPROVED W/ CONDITIONS FIRE PREVENTION U PLANNING DIVISION STRUCTURAL PERMIT COORDINATOR DATE DATE DUE DATE DATE 3/11/97 NOT APPLICABLE DATE 3/0/9 3/13/97 I DUEDATE 3/27/97 APPROVED n APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) Q DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) 5REEF The RREEF Funds Bob Benidicto City of Tukwila Permit Center 6300 Southcenter Blvd. Suite 100 Tukwila, Washington 98188 Dear Bob, FILE COPY I tho Plan Choc% ; • cnd omissions c:: • :, not authodia el violation c; ac' : code) or ordlnIMM, 111o*ipt of cantrcctor's February 27th, 1997 First of all I would like to thank -you for your help on the occasions that I have called with questions regarding this door project. As you know, I would like to change the entry doors on all three buildings of our complex from double hung three footers to single hung forty -two inchers. The net loss of doorway in buildings One and Two would total forty -four inches per building, and the net loss for building Three would only total twenty -two inches. The formulas that you gave me to calculate load factor and egress requirements work out like this: Building One has a total of 47,778 square feet. Dividing that by 100 gives me an occupant load of 478, and multiplying that by a .2 factor gives me a required 96 inches of doorway needed. I realize that is a perfect world scenario, with occupant types possibly effecting the formula, but we do not have classrooms, conference rooms etc., that should have any effect on us. Also, even after the proposed changes we would still have a total of 336 inches of doorway that exits to the outside. The above numbers reflect building One. Building Two has 42,790 square feet with 371 inches of doorway after changes, and building Three has 75,474 square feet with 366 inches of doorway after changes. I have made copies of the original prints to show the existing conditions. I have also included a drawing showing the proposed changes as well as a cut sheet to give you the dimensions, type and etc. of the new doors and glazing. Hopefully this is all that will be necessary to issue a permit to do the above mentioned work. Please do not hesitate to call me if there are any questions or further requirements and as before, thanks for all your help. Sincerely, Chuck Mahlum Operations Manager RREEF Management 16000 Christensen Road Suite 101 Seattle, Washington 98188 (206) 431 -0336 FAX: (2116) 241-7512 CITYOF MAR 1 1 1997 PERMIT CENTER /1 3/4 t 42 -14 23 3/4 _ u- i 10" 55 3/4" 8 " 26" jtt CITY OF TUIKWILA APPROVED MAR. 1 7 1997 AS NOTED BUILDING UIVT ION Bronze Finish Wide Style Offset Pivot 93 3/4" 10" Bottom Rail 8" Muntin 1" Glass Stops Adams Rite Electric Strike Adams Rite 8400 Panic Surface Mount Closer: Panic Pull 4 ,tiam 06 , Tr & 1 iSUtrATE,p 7i7trtz SaFTE 1 4L3 CITY OF�TUK MAR 1 1 1997 PERMIT CENTER 22 a * le • 1 • 1 la EAT ....••••• ■■••• ■ ■ ■ • • • ■■•■••■■■■••■••••■.* 0 . 1 4.............0611........" eX/51*1 ;) ‘3 cte4S (T 8 CITY OF TOINliA APPROVED MAR 1 7 1997 AS tiDIED BUM .H:-ioic"" ■•• . . " RECEIVED CITY OF TUKWILA MAR 1 1 1997 PERMIT CENTER nal S AT WALL ofa$e.b dNA, CITY OF TUIPWILI APPROVED • MAR 1 7 1997 AS hOIED BUILDING DIVISION RECEIVED CITY Of TUKWILA MAR 1 1 1997 PERMIT CENTER DETACH TO DISPLA CERTIFICATE - 1 DEPARTMENT OF LABOR AND INDUSTRIES /i /Nllii /iI /i / //.•f/ /ii /iii, / ••iH /iliif' L. DETACH TO DISPLAY r ERTIFICATE �1 c>2/O/ Eh�. • ' X (5-rir4, e DTIZ IBS (Tre CITY OF TUKWILA MAR 7 APPROV ED MAR ! f 1997 RECEIVED CITY OF TUKWILA MAR I 19 9, ;' PERMIT CENTER ,D91 ooli - SEAT Amor or SN86 (Tyr) CITY OF TU WILA APPROVED MAR 1 7 19 9 7 A 1 / 4 j ? iS 7 o fo$eb (..NABX 1 ,OT/2 RECEIVED CITY OF TUKWILA 99 PERMIT CENTER i-cra7