Loading...
HomeMy WebLinkAboutPermit D97-0116 - IRONWORKERS LOCAL 86 - WALL DEMOLITIONCity of Tukwila ` Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 261320 -0005 Address: 4550 S 134 PL Suite No: Location: Category: ACOM Type: DEVPERM Zoning: C /LI Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: 125 Wetlands: Contractor License No: MONNADI168MF OCCUPANT IRONWORKERS LOCAL 86 4550 S 134 PL #102, TUKWILA WA 98168 OWNER PACIFIC NW IRON WORKERS 6701 SE FOSTER RD, PORTLAND OR 97206 CONTACT GEORGE KOONTZ 4550 S 134 PL #102, TUKWILA WA 98168 CONTRACTOR MONNAHAN BROTHERS INC 1607 DEXTER AV N 1A, SEATTLE. WA 98109 ********************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: REMOVE. INTERIOR WALLS (NON - BEARING PARTITIONS). ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: 5,768.00 PUBLIC WORKS PERMITS: k(Water Meter Permits Listed Separate) Eng..'Appr: Curb Cut / %Sidewalk /CSS: Fire Loop Hydrant: No: Size(in):. .00 Flood Control Zone: Hauling: Start Time: End Time: Land. Altering: Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start End Time: Sanitary Side Sewer: No: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: .Public: ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 189.71 ***************************************************** * * * ** * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:_ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other s ate or local laws regulating construction or the performance of work. I am - uthorized to sign for and obtain this development, permit. Signature: Print Name:__ DEVELOPMENT PERMIT Occupancy: OFFICE UBC: 1994 Fire Protection: SPKLR & ALARM South: .0 East: .0 West: .0 Sewer: TUKWILA Slopes: N Streams: k/i/R IN = �vr slar4 Permit No:. Status: Issued: Expires: .Phone: (206)728 -8600 Phone: 2413-4246 Phone: 206283 -8780 k -__ Date: (206) 431-3670 D97 -0116 ISSUED 05/09/1997 11/05/1997 Date: ? '" 7? 5912 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address 4550�'S 13 FL Permit No: 09,7 - 11116' Suite Tenant Status: ISSUED Type : DEVPERM App;l ied . 04/08/1997 Pa'rcel.# 26 1320 -0005 Issued 05/09/1997 • k* k k!st* h *44.*** k **. * k *: * ** *,* * k *'k *** r* * * * *•k *** * **4(*4 k:;k *•k* c k, 11. R 4;k Permit. Conditions 1 - No c han g e's, will ibe - :made.: to :' the plans Unless approved :by the Architect or Engineer and the Tu,k 1,1Aa Bu`i l d i na : Di V1 s i on Electrical permits. shall f qb..t inedr- thro ,the' Washington S "Gate .:Division, of L:'bor-3 and: I,ndustrries`" ° arid =aFl.l .electrical, work wil ; be i rispecteii by ' tKai aaenc • (248 - 6630) • All mechan,ica wu► k s Hal -l be,. under ,separate permit issued by Vie, V 3J r " • - . t he C i trr of , ,ukwi l ; , -,. ,.r Y s x, 4 A-11 nermit,,,..,-,.,.-,• 'inspe4rob sit o'i ion"'reca : , art ap0r'ove ans ▪ hall.: be avai la0l �.;at t.he u p rior t t.h'e' :s,tar t= x any,. ct n' str uc { L Th.e s e..fd ocuments: ar e its . be maintained :arid avail able until ti,n'al insp approval,, is or an 5 Any e'Agase.d insula,tions:.ba,Ck?ing .material sha1�1 h Flame a ▪ Fme, 5p ead. Rating of 25 at less',] m and aterial shall ?,bear ` r den0?:i ;4 :i fc3`t°iun ,hawing constr • t fire pet formance rating the.`rreof:.. '; b All uct he ion , b. done ,i`n conformance': with approved t ,1 p lans } an reo i.remen t of the Uniform Bu i l d i ng Code : ( 1994 E di t ion) as amended Un'iif or, m Mechan?ca l Code (1994 . Edi t i on, ) , r� an *ashin ton State Ener `rr :Cod,e - (1 994 Eld`i ` t ion).:. { 7 Va i d i t,y,'of Permit..:: The issuance of a`' permit ' or appsroval.J of$ k pl''i,,3,-.(6. ns, speci flea tio ns, = and' computations ,shad l not. be con-t r�' ' t d 'f�to 'be �.a per m�i tJ ~ffor;r, -orb an a approva l o Y. t an . v i'ol t i aon of nv o`f o pr'V,7:s,ion s' of" the, bui l`d ing;�' code or offs anv ,, k ,� other d o. of the �'-i�urisdi "c,t it5ii\ 'a'No'. presuming( to;°'`f� givef�,c to ca'ncel,�the - pro`vi,sionse,ot„, {thi'`s 0, ,�; +� s code i t r 2 �t ha l l `be Valid. Y .c ,.: . ,-., , . .. � ys VENT LATI;0N ,I5' REQUIRED FOR ALL NEW `ROOMS,,A 4 F N E4 <'y OR EXir TIf G` BUILDINGS IN CONFORMANCE:WI,THf THE UNIFORM` ` BUILDING, CODE, AND '' WASHINGTON STATE' VENTILATION' AND INDOO AI, QUALITY CODE, CHAPTE 51- 13` �,1 rt Project Nam /Tenant: 0 N)\ND -Y -� 1.6 c r-�c o Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ ' a ehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel M Office El School /College /University El Other Va,te of Construe , - ? -7 Site Address: ; f1( (02 .. r � cv 4 City State /Zip: IA S' 5 i 13q iI-( eL -rL �v� LA ( 0/ X1(0 5C Tax P c =I Number ► , :f e Property Owner: (PIc - Ow j Qow r= t2S -u ,>i Phone: r , 4 "3 -) . '7 Street Address: r � n - 1 Q 1 .5 i'" , i i1-=e- an City State /Zit): C n -6 C Fax #: Contractor Phone: Street Address: A74 t2l 72- :47 %% i 1 � / - City State /Zi . . /( 4 f /c» Fax #: Architect: n n Phone: i f 3 c Street Address: - j �� LO - �atteSOA Dr. -4k State/Zip: Tuj<WiLl ugil- 4oK Fax #: 7 lo - 9 Engineer: -✓ Phone: Street Address: City State /Zip: Fax #: Contact Person: Phone: Street Address: !ff 5 i (NT - eL. -tkla7. City State /Zip: "Taw i L -A IAA `4& - Fax #: 1 - CJS) Description of work to be done: , Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ ' a ehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel M Office El School /College /University El Other Proposed use: El Retail El Restaurant ❑ Multi- family El Warehouse El Hospital ❑ Church El Manufacturing El Motel /Hotel pi Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes '3 no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 7"" no Existing fire protection features: % sprinklers q automatic fire alarm El none ❑ other (specify) Building Square Feet: / "1) 4 7/ l existing Area of Construction: (sq. ft.) 1 a :), ) Will there be storage of flammable /combustible hazardous material in the building? El yes CI no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUI'WILA Permit Center • 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial I Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS.SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) . El Channelization /Striping ❑ Curb cut/Access /Sidewalk El Flood Control Zone ❑ Hauling El Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering 0 Cut cubic yds. 0 Fill cubic yds. El Landscape Irrigation ❑ Sanitary Side Sewer #: El Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage El Street Use El Water Main Extension 0 Private 0 Public El Water Meter /Exempt It: Size(s): 0 Deduct 0 Water Only El Water Meter /Permanent It Size(s): El Water Meter Temp # Size(s): Est. quantity: gal Schedule: in Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may_extiiKettiVillitie for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section .4f I i i th m Building Code (current edition). No application shall be extended more than once. Date a plication accepted: � _. c_) APR 0 8 1997 rennnrr Cr�f,tV Date application expires: Applicatio -ren by: (initials) -t_ PLEASE SIGN BACK OF APPLICATION FORM CTPI:RMIT.DOC 1/29/97 BUILDING o AUTHORIZED AGENT: Signature: ;�� ----- Datep PP Print na�rft3 / /1/J V/ /t CWA/ett T e2oS Phone: Fax #: Addres /6 07 � %7 .., / V City /State /Zip C ' / j - %14 ALL COMMERCIAUMULTI -FArA Y TENANT IMPROVEMENT/ALTIVITION PERMIT APPLICATIONS MUSTS E SUBMITTED WITH THE FOLL ING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ 71 Complete Legal Description ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ 7 1- Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of /// any hazardous materials; dimensions of proposed tenant space. ❑ � Vicinity Map showing location of site ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ P Indicate proposed construction of tenant space or addition and walls being demolished ❑ Construction details Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ 71 Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPL:RMIT.DOC 1/29/97 : -,. y ***********k**kk***********A*k***kk***A**k*A****************A** CITY OF TUKWILA, WA TRANSMIT *********************************k******************k****A*A**A* TRANSMIT Number: R9700563 Amount: 189.71 04/08/97 15:18 Payment Method: CHECK Notation: MONNAHAN BROTHER Init: SMC Permit No D Type: DEVPERM DEVELOPMENT PERMI Parcel No 261320-0005 Site Address: 4550 S 134 PL Total Fees: 184.71 This Payment 189:71 Total ALL Pmts: 189.71 Balance: .00 • Account Code Description • Amount 000/322.100 BUILDING - NONRES 112.25 • 000/345.830 PLAN CHECK - NONRES 72.96 000/386.904 STATE BUILDING SURCHARGE 4.50 9344 04/09 9716 TOTAL 189.71 Project _12W) leN POYia/V- Type of inspection F. 01/4... Address: 1 4 .ss .. 5 , i4-1-f1Date called: Special instructions: .1 . Date wanted: Requester: , Phone No.: -24r _ 4 .01............*11...1.11■*1■••••••••••■••• INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. TO PERMIT NO. 0 431 Corrections required prior to approval. %./ Date: (//24`,7 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: WolerWIWINOMW, Receipt No.: Date: • P roject Name f df /G J ! /'C' -lf Address 5/J`�S7? /r , / Suite # /tZ Retain current inspection schedule Needs shift inspection 71 * -M7 A I , ,C4V,v 1'�(Z�1'G�TH.KYx��'{'Zv Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authpr Signatur City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief • TUKWILA FIRE DEPARTMENT . FINAL APPROVAL FORM Approved without correction notice Approved with correction notice issued 4 r„ Iliw, Permit No . ,.,Y - O//C 6,././4,./afat Dat FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 ACTIVITY NUMBER lYn - © Ike DATE L I ' S " 91 1 PROJECT NAME l R(A\/ O F---14-E-1 L 0 cA L- O DEPARTMENT: UILDING DIVISION 0,, FIRE PREVENTION ❑ PLANNING DIVISION ❑ V4,11" MYQ 1 ('1� i u (� - lr f LIC WOF:KS ❑ STRUC f ❑ iJ 4 PERM COORDINATOR ❑ DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE L A - 1 - 6`1 COMPLETE COMMENTS �gM�T CooLbINATO. COP4 PLAN REVIEW / ROUTING SLIP TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL I INV I APPROVALS OR CORRECTIONS: (ten days) APPROVED ❑ APPROVED W/ CONDITIONS ❑ . NOT APPROVED (attach comments) ❑ REVIEWERS INITIAL CORRECTION DETERMINATION: C:ROUTE -F NOT COMPLETE ❑ NOT APPLICABLE ❑ DATE DATE REVIEWERS INITIAL DATE DUE DATE L ✓ Z - 11 DUE DATE APPROVED I 1 APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Certification of occupancy requited. ; • 770^1 PUBLIC WORKS APPROVED El REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE-F L C. DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE fia NOT COMPLETE COMMENTS '€-X.:( TUES/THURS ROUTING: PLEASE ROUT APPROVALS OR CORRECTIONS: (ten days) DATE PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER b - 0 &V DATE g Cli PROJECT NAME P-CAWi il-14-aP-S L Duct._ 8 tea DEPARTMENT: BUILDING DIVISION U FIRE PREVENTION PLANNING DIVISION El STRUCTURAL fl PERMIT COORDINATOR El ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) — REVIEWERS INITIAL DATE 4 DUE DATE 1--- - 10 - 6 C - 1 NOT APPLICABLE NO FURTHER REVIEW REQUIRED E I DATE -A DUEDATE APPROVED W/ CONDMONS/1 NOT APPROVED (attach comments) Ei CORRECTION DETERMINATION: DUE DATE APPROVED El APPROVED W/ CONDITIONS n NOT APPROVED (attach comments) 0 (Certification of occupancy required. AVSfreg �c:7N;•5i'M!rri;!aG;wa a °w ?12';lC";tJ1G :':X�?stSiai9°%!s41.1 SY1;arrrYF'1tr$PO4 0.! u9rx .+•err: ^.+ avx:. ca'+tncsrJ, +irk!xc HM^:xo t:tM: "a53'i�'�N P. YL ' DEPARTMENT: BUILDING DIVISION fl PUBLIC WORKS REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F L DETERMINATION OF COMPLETENESS: (T,Th) PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER tY fl 0 Ikv DATE - g PROJECT NAME g(A\ \ 0 W -5 L 0(_,b L- g APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: APPROVED n APPROVED W/ CONDITIONS FIRE PREVENTION PLANNING DIVISION STRUCTURAL El PERMIT COORDINATOR Q COMPLETE El NOT COMPLETE n NOT APPLICABLE .— COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED E ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) DATE DATE DATE DUE DATE L 1 O _ Ck.1 I DUE DATE APPROVED i l APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) E DUE DATE NOT APPROVED (attach comments) E (Certification of occupancy required. ) 5 t�+fi'F'1 4 ,itA'AY+ ACTIVITY NUMBER Y\1 — 0 \ Q PROJECT NAME \Z01 0E- IcaT REVIEWERS INITIAL C- APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED n REVIEWERS INITIAL C:ROUTE -F "JhAw;t va rrr?•.:ux:9 , 144g xreAll r tNv!.Bt. ?. PLAN REVIEW / ROUTING SLIP DETERNIINATION OF COMPLETENESS: (T,Th) COMPLETE E NOT COMPLETE COMMENTS LOCA DATE - - 7 DATE DATE sh6 +, rx•tsuirtiAL;xY� *.G7°Rj�f NOT APPLICABLE p DUE DATE DATE L \ - g 1 8 DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION C PLANNING DIVISION a PUBLIC WORKS L STRUCTURAL p PERMIT COORDINATOR J DUE DATE 10 — c fl TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) DUE DATE L\ 2 y - 9 APPROVED l l APPROVED W/ CONDITIONS C NOT APPROVED (attach comments) APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) A1�ny",StF•cl�R2�€3�6hCT'.f; PUBLIC WORKS COMPLETE COMMENTS ' REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F r:YYtrxSi titk�c,+ r.; aacmufxstietisiwe :, ?nzas+?acc�w1. - )4 PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER Yfl — 0 Ike PROJECT NAME (ZO V \\ C PLEP --a L 0 CA L g 1 e DEPARTMENT: BUILDING DIVISION El S DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE EI NOT APPLICABLE C1 TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS I� DATE / CORRECTION DETERMINATION: APPROVED APPROVED W/ CONDITIONS APPROVALS OR CORRECTIONS: (ten days) DUE DATE APPROVED El APPROVED W/ CONDITIONS ❑. FIRE PREVENTION CJ PLANNING DIVISION STRUCTURAL C PERMIT COORDINATOR DATE DATE DATE - S " X11 DUE DATE " I O — fl NOT APPROVED (attach comments) C] DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) i April 15, 1997 Fire Department Review . Control # D97 -0116 Re: T.I. at Dear Sir: City of Tukwila Fire Department I$ONWORKERS LOCAL 86, 4550 S 134 PL John W. Rants, Mayor Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S7$4404 • Fax (206) 57$4439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 3 required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) 7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 C: City of Tukwila Fire Department Page number 2 Thomas P. Keefe, Fire Chief halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575.4439 City of Tukwila Fire Department . Thomas P. Keefe, Fire Chief Page number 4 9. All,new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required .fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) .575-4439 Page number City of Tukwila Fire Department requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired., restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) John W Rants, Mayor Thomas P. Keefe, Fire Chief This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila John W Rants, Mayor Fire Department Thomas P Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575•4439 1 �Syit ' %'i ``it wr RE G1Si.i A I ..•1 {Y 1 J t B ERlS�v'i�.`� yN.1 '. . rt^ ! ` P!Ri' ATION .1• t/�}TE•y 11. i �; • , 2.7:�: • . 1 .. ,. �. ^ ►. ,.� .:,t7. •.. !. .t . 5.�.. . ;4 : � . ., �..,`- .�.r..r'..L � c •• n r�a..� _ �'_ _ 1 __ _ _ — � '— ..r . . . 1 • t ' • ,�i� '� -r '. •�1:�:� �,• � • �'!: r��� .;�: :i {, �;��� .II � " i •. : � ':L ;• �'4� 1 . .{t� ,,. e t• ; ' M;�•`�i jG, •' Z ' i ■r`•, f7i�:t.P;'A � T " ' � 7r'� �•� tz•. � w 1�� 14 r t �` �•• 1�. • ' , I '� 1 ti• ' H • � •1 I i it i'' •' ,.1,1,' 1. 11 j rt "•/.)W 1 • A ' it` `tiS ,. .•; ; $ � n Z. " ,c"'X+ ►w: � % �' ' ' ',j, � •� t .P,±�+i�. h � n.�4.. f � •: 1 Sl: :!• � r , �. �.ri iN� •'• " ":�, ' ''7l � :'4� /. ' : �• 5 a e•;�:,r.•,•,ht� 7 +;•+��•i y 'Tr;;; II,; •� { i 1�.,�,� -1i,ti.,,•.� ��: , c'.. ✓: <., 'Y'.' •):�',, Y ,: c Y DEPARTMENT OF LABOR AND INDUSTRIES 1_ INI =' T!!y[7 G IY i IC TL> I' E 5xI;i iNC, c-,W LOc t 2wCtA. x L o !P�fRQC For- Per—ma—Doti 1-IFP,G (Nar rp4fqNE 7 ft LiLIP ?a GK- 5 /s` r x a.w>3. - iso 4I' !v Gib! I ND LATi e;• 0614 GEM ENT PP�i1 -11c3 i WAfNP'L %XI�iTNEl CONCRETE r, mi_u =uteu gn u I - su- �xranl- nTEMMIr wi t- u= 7_ MI= 1fl_ Lam.!_ =I _ —l�.e 4 ry xi zP'MO -G NAIL= INS ILO < O.G,, G/ P- f E� CPDWP DK!vEN # 4CHOI ) 20 GA. X (o' pj %c - rR C.g FASTEN 12 i 2 5TH 141/IrQ7 x Vi-" rLi WASI -r( HQd7 0 50k , S!DV, EH < Z 1 EXiTi'\4 WALL GELTIONt, Ti MI- 42° ABOVE FLOOR AND NOS I NG OF STAIRS OCCUPA g 1 wim 1 1 NCY TAX ACCP,SSORS •NU 91605€z03 : CONSTR UCTION- TYPE `VN SPRINKL)$ SITE A : 198;7 S F +/ .�. ",` B UI LD ING AREA : 19 SF AREA O REMODEL : 1820 SF PARSING : NO CHANGE LEGAL DESCRIPTION: Refer to boundary line adjustment file. #88 -7 -BLA Lighting Budget: Vactional Welding shop : 2.3 watts /s f room: 1.35 1.2 watts/sr Hall /Office : sf En Design: No':change - existing semi heated EX. DOOR • ! p NEW DOOR • EX. WALL • NEW ST SEL STUD WALL EXISTING WALL TO BE REMOVED WOOD RAIL N +34 ABOVE TREAD 'NO l I" 1/2' Sg, VERIFY TYPE OF ;RAt ✓X�STt�� _. L1 PRX`L :t�r3J r j - - - t'— SCALE: I I /2" = t'--0" SECTION 1 � l 171 . <iLALE- 1 HOU B1 E I Z Ef - wl 4,1210141 ib "O,Z. w /H-iM Er (1.)z=4•4 HEnt*42 at& s! N,NEvi NO1B: W (Z) 2,12' ` <} x4 LOIUMM `�(ZEI EIZS fir? E( j IN WALL,NEW +MIV /A4 NEW I EACH 41 I understand that the Plan Che& _yak, are I subject to errors andom - plans does not etI ho or ! adopted code • r- - ` " -j tractors c._ •.tap W a l l s .:n i }o g / .//, SEP� REQU ? I Et 0 GAS PIPING CITY Q' CU1CVti' BUILDING DIV rn D °1 7 ®I '(, 2 2 lil St �I U ,Oq t v V es Z oTh'S 1. office wail. 5;8" gyp- bd. bottt sides, 3 5/3• steel studs p 24" o.c- from floor to under side of hasp. ceiling. See 2/TA-3 for wall head detail. 2- hall (room 47): exist -i g smoke detection system to provide coverage in lieu of one -hour construction. Modify existing sprinkler system to provide coverage, per all des, in hall and new offices. 3. 10' high partial height wall. 5 bd. both sides with 2 x 6 A 16" o.c. ` 10116111111111111%11•11PU 11� \vc::? >ti�^_.✓ 1��.._� ' /:� -lip:✓ �- S��. 464 L- rc M eicertm proiValoN r }4R?7M.& �vsRaR— i 147�11`ttT�"'� OFFIC r5 WALLS TotovE1> 7CIZT _1uovl 4 4 L.k ivima 6 L4 waft -101- EiU No wolex '— prn.bLS „GMEf7 Sr. -1 ? rcNE (1,^'i cisi..) tcEE .Tri l I = L1t13>Na D occ 14 , 7160-1 • — 7 ot t Of.rlari kir•+SCOT fti ;4W6 LEAF pliu- 1- 1- 101.lI vat- w /t'c r FrOrratiitt-IIMVAisrnr i i-ti. > 4,91 -0 V 17 6 r1--0 l Ft1J 1_ L41. GA1E -4.- 1 -1 ruDor FL-PN 1 NOM P% r*ION IN R'..1I W FOL Mf xiMUwi otai kFICY OF 10 P iGNra — 2 5ZZAN1H J 'L:AN= XIgTlHC Y _ 3' x 7' solid core wood door, metal frame, 1 1/2 pr. butts, lockset, silencer. 3' x 7' solid core wood door, metal frame, 1 1/2 pr. butts, latchset, silencer. Doors to be 20 minute rated. 3'. x 7' solid core 1 hour door, metal jambs, 1 1/2 pair butts, closer, threshold, latchset, smokegaskets 3,12,13 3' x 7' solid core wood door, metal frame, 1 1/2 pair butts, latch set, silencers. Pair of 3' x.7' solid core 1 hour door, 3 pair butts, closer, threshold, latchset, smokegaskets, astregal, flushbolts on inactive leaf. Note: Inside handle must be free at all times. (One-hour rated) 9.,10111. Verify rating of existing door and frame, if not minimum of 20 min., remove and re- installnew 3' x 7', 20 minute fire rated doer and frame with 1 1/2 pair butts, threshold, latch set, and smoke gasket, install closers as needed. RS SCHEDULt: pi„i wf5j po &5 Utz "s '.`. O:.i`.s ISF.Att 1,3 Floor : Existing exposed concrete, rubber base. Wall : Paint new gyp. bd. Ceiling: Existing exposed structure. 2 door : Ex•5i::g exposed concrete, rubber base.._ Wall 8' cement board wainscot, paint new gyp. bd. Ceiling: Existing exposed structure. 4 Floor Existing exposed concrete, rubber , )(:: Tld11 Wall Paint new gyP. bd. ) ? 0 Ceiling: Paint new gyp. bd.. y . 1,c3'l 5 , 6 Floor M ` carpet - Ceiling: Kee gYP. bd. Kew Wall : Sew painted gyp. bd. Ceiling Existing suspended acoustical „,i- GO(V \5 0' ceiling LI f loor Exi'stiog concrete CT[Y °FnEKwu.n Wall : existing. panted gyp. bd. and repaint existing. AFB 0 � i997 PERMIT - INTER. I L\1 I S g N is 5, 6.1 SQ S