Loading...
HomeMy WebLinkAboutPermit D97-0134 - SPRINT PCS - WALLS, CEILING, LIGHTING AND FINISHESCity of Tukwila �- (_ (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No:. Address: Suite No: Location: Category:. Type: Zoning: Const Type: Gas/Elec.: Units: Setbacks: Water: Wetlands: Contractor 262304-9110 17540 SOUTHCENTER PY ARET DEVPERM V-N 001 North: TUKWILA .0 South: Sewer: Slopes: Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: .0 East: .0 West: TUKWILA. N. . License No: .MARKECWO66NU. OCCUPANT SPRINT PCS 17540 SOUTHCENTER PY, .TUKWILA, ..WA,.98188 OWNER PACIFIC. NORTHWEST GROUP A C/O:GEORGE MCELROY ASSOC`INC, 3131 S VAUGHN WY STE 204, AURORA C CONTACT RICH MAJORS Phone: 888 842-1292 1100 MAIN, SUITE 2230, KANSAS CITY, MO 64105 CONTRACTOR MARKET CONTRACTORS LTD.. Phone: 206 872-9585 6040 SOUTH 194TH STREET, KENT, WA 98032 *************.******************.******.*.******************"***********************fir**** Permit Des.aription: INTERIOR TENANT IMPROVEMENT INCLUDING NEW WALLS, CEILING, LIGHTING, AND FINISHES. ************************************************************************************ Construction Valuation: $ 90,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng..Appr: Curb Cut/Access/Sidewalk/CSS:. Fire Loop. Hydrant: No: .00 Flood Control Zone: Hauling: Start Time: Land Altering: Cut: Landscape Irrigation: Moving Oversized Load: Start Time:. End Time: Sanitary Side Sewer: No: . Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: ********************************************************** TOTAL DEVELOPMENT PERMIT FEES:., $ 1,365.34 ************************************************************************************ Streams: D97-0134 ISSUED 06/23/1997 12/20/1997 STORE 1994 .0 Size(in): End Time: Fi11: Public: ************************** Permit Center Authorized Signature: _ __I-_ Date: (Q— —1 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit cancel the provision of any or the performance of work. development pern t. 4/ Signature:Z4" does not presume to give authority to violate or other state or local laws regulating construction I am authorized to sign for and obtain this f"'u✓ Date: L/7: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 'CITY.OF TUKWILA Address 17540SOUTHCENTER:.PY Permit No: D97 -0134 =` te': 'Tenant.. Status: :,,ISSUED: Type: DEVPERM Appliad 04'/17(1997. Parcel " #: 262304 -911Q `Issued 06/23/1997 5k•k** *:k k k * *k * ** *'k k *** * *'k * * *'k * * * *'k ** k k* k ** *•k.'k ** *•k * *** *'k * *• **k k'k•k•k "*-k k *•k* * * *"'k Permit 'Cnndi:tions chancres wi 11 be made' to the plans unless approved by the Architect . or.- Engineer . and the rukw� 1,a Building: Division: Electrical ..per.mi is ..shall ,. be +obtained tht ough'the Washington State Division `of " "bti►�:anti'':Inciustr i "e`s and�� ^i;1 electrical work wi11._ inspected by : th at,.agency.: • All mechati cal, work .shaT.l, be, under` separate; t' the City of 4,0 ),wi 1a ; All permsts records, and approved plans tslhal1 be avai table .a't th`e job site - pri or" to' the.; star t.,Vf any con structl,on.. , rhes`e .documents :are ,to be maintained :and a uriti °1 ':final inspect;ion'tappro "val.is granted Any rnew, l ina: grid and :- 1-1u�'ht f ixt'ure instal`1 "at o }is, required .t meet bra,ci.ng ,.requir•ernents for Seisrn Pariaition wal is • attached. to 'ceil:ing,rgrid" must be laterafl braced. 1f o,ver eight' (8)•-feed in length. • A11 ; sconstruct ion to'be done? tin co,nfo'rrnance. with approve,+ 0an4 and requirements ,of t,the ,Un.ifform d B,ui-lding, Cod eS,(1994 :; Ed0 zort) a amended,,, Un,i,form Mechani±:`al Code (1994 E a ton State Energy'S'Code ;(19 E) t ion) Va Pernri t T h'e ;i s.;u ance oj' a perm i it or approv'a'l a p1 a n specrticatzons, {a,nd ec Mom t'atlons iha11 not be cony. strued ,tor b.e a perrnit. f<dr, or an;,appro' ari any violattan of i an5y of t the provisions of. the bul!di code; or of an , __ athz ' {ord i n races., of the j uri sd ict ion Na : permit pr.;esumi;ng t gi:ve .auth „or'iXv to vio'1ate or cancel th e provisions ofwythTs code�islail` he valid. 9 Ther e ;'sha l l be ;no occupancy of Jthe `bu,i 1 i ngCsJ: ° "irnt i 1 the final 'inspectionha`s been completed by ° -ttie "'Tukwi la <Bui ldin g Inspector. , 10 VENTILATIONN; I5` REO,UIRED 'FOR ; NEW ROOMS AND SPADES " :OF`.NEW OR EX IS TING; �8.UILDI = NGS IN CONFORMANCE WITH THE (JNIFORM BUILDING CODE ,AND THE WASHINGTON, STATE VENTILATION"':;AND INDOOR AIR DUALITY, CODE , CHAPTER 5 ] 1'3,, WAC. Project Name/Tenant: Existing use: fa,Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Value of ConstructioruL B U J )00,, ( _ 6 Site Address: C Statepr: i 1- 4v - �c lc._L `Ct =c (V!(.t.:t•� ' Iu t a u /Zi �- tlt.,/: Tax Parcel Numbe & L . .' co 1 0_ Property Owner: ''eki (6:- N LO cAttW(' jNI %/c. - ("C, VA L., oZo U Phone: l .. U`IG' Street Address: i 4 ('l� 6.10 �� {'Y«' City State /Zip: "U1�..Uic,/> ? Wa `61 06 Fax #: C; 4-140; Contractor: Na Lt EX ;2vTc(Z1ti t IsL.1) Phone: Street Address: City State /Zip: Fax #: Architect: E FS ;, / U � Phone: : 8_ 41:2. • l 2, Street Address: 1tOC.) SAW, 5115 2 City State /Zip: k NSC aril. 1100 G=4tL) Fax #: i'3►6,.`3d;Z. - t&7 Engineer: . - Cjf,L x:N ti �lvC�i NE Phone: ` (M 2. 1 - T Street Address: City State /Zip: \ le 'Z'( (1 • I (...NJ a) ' KG l'-r47.A4- Fax #: o (3 . 4t'42 ' n Contact Person: Pv -t Phone: e.-fa.) rt z i ZD'Z L'.CN•t" ca) 'G Street Addr ess: l _ { \Icb E� i`J < ":71l.- rr � v: y\ City State /Zip: l - F xlV (2j) I'd C.) &.4 (0.S Fax #: E' - I tal Description of work to be done: , ;T Fi t.. H i tJ(.0..)P(NU Pt 5-; COAL-Ii= ; CC( L•I tJf- , C-4.( j-t7'11 AND 'rt NIyrtiG5 Existing use: fa,Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ra Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse CI Hospital ❑ Church ❑ Manufacturing ❑ MoteUHotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes no Existing fire protection features: ❑ sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: �� 2 existing Area of Construction: (sq, ft.) 72 `"r ! - Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 71 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Date application accepted: CITY OF TUV'VILA Permit Center • 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. CTPERMIT.DOC. 1/29/97 APPLICANT REQUEST FOR PUBLIC WORKS .SITEJCIVIL. PLAN :REVIEW.OF. THE ..FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal ❑ Miscellaneous Schedule' Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only Date application expires: Application tak by: (initials) PLEASE SIGN BACK OF APPLICATION FORM BUILDING ON5R OR T QRI ED AGENT: Signature( t etu tk, (i ( - r . Date: A (ice I Print name: , , .� V Phone :�, ., Z ...� r V2 ,, . Fax it: ,, -' _ r , i Address 1l iX: t_. --`4i t,j ' :)01/ . '( .'c- )C:% City /State /Zip v./4\1,-,),,,z, c Cr L V�`�.' ALL COMMERCIAL/MULTI -FAY TENANT IMPROVEMENT/ALTIIIATION PERMIT APPLICATIONS MU BE SUBMITTED WITH THE FOLL ING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER v ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include • ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERM I'T. DOC: 1/29/97 *** *AA•A * * : *Ak* *ilk* *k * * k k *•A *4- A*A* ** *k ** * *A *kAkk *1* TRANSMIT ,TY GF TUKWtL.A,, WA., zh,kok: * *Ak.t kk * *•k * ** 4 *•h"* * * * *** *k* *•k *A* **4 *** **A * *** * ** *k *AkA* ..1'F Pi tlum .R9700658 -Amount: 42.::00 1.0/15/97.16:12 Pevrnent'' Methiud. `CHEC1t ` Notation:: MARKET ' CONTRACTO In.i t: WfAI3 Permit No:: 'D9.7 -0 114 Type: DEVPE.R14 DEVELOPMENT PERMIT Parcel Nix: 2623.04-91.10 Site Address: 17540 SOUINCENTEU . PY Total. Fees: 1,40 Payment 42.00 Total: ALL PNitsc 1 k3alance .00 k* *•kk * * * *•A * * *A * ** * * *k* IS*** 4ik*** k* ** * * *k.. *4 * *$ * * * * *i• *Q *4** Account Cnde., Description Amount.. 000/322.090 BUILDING INVESTIGATION 42.00,.. 5113'10/16 9717 TOTAL . 42.00 ** A***,*k k W*. k*****'*` k• k'** k.* 1s**' t4*********+ 4 * **•*•.4 #•.4 * * **A** * * *k *k* *k ** 1:TY. OF 1 "UKWTLA;. WA �' TRANSMIT- *k * *0k * * * *• * ** *,k•k* *k.* *****kk•k *k * *A '::TRANSMIT NiAm,ber - R9700ti02 Amount; 824 2 06/23/97 1.3c28 . Paamen t Meth.od c CHCCI( Notation : MARKET CONTRACT° In i t : SLB • Permit No D97 -0134 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 262304 -9114 Site Address: 17540 SOUTHCENCER PY Total Fees: 1 This Payment 829.25 Total ALL Pmts: 1.v365.34 Balance: .00 k * **•*A ***** * *AA *** * *•k **•h•A*A ** *** **1x11 *h•* ***•* k * ** ** * *•k * * * **i **+,i** Account Code Description Amount 000/322.100 BUILDING.- NONRES 524.75 000/386.904 STATE BUILDING SURCHARGE 4.50 ,1539 06/25 8717 TOTAL 829.25 CITY OF TUKWILA, WA - -wkj TRANSMIT *********A**********J;?a*w** * *******k***********A********* TRANSMIT Number: R9700569 Amount: 536.09 04/17/97 13:42 Pavinent Method:: CHECK Notation: PERY KESSLER CON Init: SLB Permit No D97-0134 rype: DEVPERM DEVELOPMENT PERMIT Parcel No 262304-9110 Site Address: 17540 SOUNCENrER PY Total Fees: 1,365.34 This Payment 536.09 Total ALL Pmts: 536.09 Balance: 829.25 *4***4****/.*4,****k****i*IkW*****4iA***4.***********41 ****i****Is* Account Code Description Amount 000/345.030 PLAN CHECK - NONRES 536.09 'T39 04/21 9717 TOTAL 536.09 Project. r , n + P6,s Type of inspec ( rg4 1. • dd e C.- p Date called: i , L L 4r pecial instructions: 3f, CO 7 , i po &1t, Date wanted: t 0 ... 1 6 - crErv a.m. Requester. pr 1 1 .---, .. L -D---75r, L. I I Rannon.aftWACCOMP INSPICTIOttRECOilD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: Date: i $42.00 REINSPECTION FEE REQUIRED. Prior to inspectiL, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: iil R i Date: 1.0 (206) 431-3670 • Corrections required prior to approval; Project: C N11 . Type of inspection N Address: p " Date called: Specia i structions: ' C„,f 1.-t N(1 3o � O — I I � — r.. : ; y D ate wanted: /Q -97 a.m P.m. equester: - kt) PI) S J � hone No. 346 - co 3-.7t4 ...rw.awwamccrn.••v r INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, WA 98188 Approved per applicable c COMMENTS: ......wwwwv ,xrp+Ctxa�ewmams aa�s+tGtSre+..A}WfGX49M. INSPECTION RECORD Retain a copy with permit ".r . 4 . 4 <110 f1 Corrections required prior to approval. (206) 431 -3670 4 13/ - 477 Inspec or: 1 Date:m v � $4 EINSPECTI FEE R QUIRED. Prior to inspection, fe must be paid at p300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No.: 4 Date: proj i. �� Type f insp ction: Q s D\171-1- d.�a rl .0 c .41 ti Special i trtsa w ed: (� a .m. " R,eq uester:A t- Phone g _ Approved per applicable codes. Receipt No.: • INSPECTION RECORD Retain a copy with permit INSPECTIO NO. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 [4 Corrections required prior to approval. COMMENTS: J c €t L10 ,s ul trim. t s Nt`st Inspector: • Date: / / y , 7 $ 42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • f. Date: (206) 431 - 3670 Pro' Type of inspection FNAL Addres : 0 S ")(75 R ) ; 4 Date called: 43, (0 _ -- Special instructions: rtew,ed: quester: P hi 1 - Phone No.: r7 2 _ 95 8.5 . . wwsarr..n,oc. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspecto $42.00 REINSPECTIObf' FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. Date: Date: (206) 431 -3670. COMMENTS: t ( cV.m w _ m•tt > ►, cm_ c& a S . 2 ) V t f: 4• C Cn /c A( C-C) L ( TO V) F--1 C A 7 (---r AJG I N S u LI td / 1.461-1r 1t=NT7t4G. 77WU ' p v o'E / rJStti.'GA- -i 7mJC bcfi r 6 'r' ->, 4 1 wm - 7}11- 1./K- -- Azrz-% Cr- VA- t-vl" i.Jn IT 4 1 r ,J f j ' N " - - A-(` ( 1 . 4 - 5 - 1X -difl i. j j XL . (T NN NS 1 flu tJ O L i d c 0 a- T iJ Al (t-c7 V`)2 1d GA- �i74)d. 5 ) 1tv-s u r—c' Pn c►c.; fpr A-t AAA.. w r IA )J / 1PP,,.., ft o r a...),„, c r' W.m A (-Lii7n €1 5 rnd lc..- /Lh 06 - CA P t' rc 61 8 4 1 f 4 (, - '^ 7O"NJ R-, r'"' IS as ,{t-PPii usO Tt cS P.r'J A r 714-13 , i't m,' , r t Project: ,rr P�-S Type of inspection: h u Pet....- Address: (7 4p S,Q. f i Date called: .1 [SI Special instructions: Date wanted: r 3t (97 a.m. Requester: r t Phone No.: 7 Approved per applicable codes. • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 EACorrections required prior to approval. Inspector: Date: .7/31 ig7 ri $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: -Date: ProjeS p g.) Nr P C Type of inspectiper:, N L 9 i s 5 30iiC m." eLt Date called: 1 , 2.1 ¶ Special instructions: Date wanted: _ 25 .9_7 p.m Requester: �, ` Phone No.: 51 c- , ..30..(42 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 SouthceRtv Blvd., #100, Tukwila, WA 98188 Inspector: I - 5 - /e'e/ 4- ) a_c Date: /;..27 (206) 431 -3670 Approved per applicable codes. /J Corrections required prior to approval. 775 $42.00 REINSPECT ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: - t r,-- -FC-3 Type of inspectio . :0 LI Address: , ; ,,',. ( '. C. , -041 Date called: Special instructions: Date wanted: 7 1 f 2-1 a.m. Requester: Phone No.: Arr.w...1.01.1%.11.1.**1.01•41‘ INSPEcTICIN RgCORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IA Approved per applicable codes. COMMENTS: 1Z1 I IASOLA-1€ r Owl Pr f-ENA %1C rsiSLAC,PrilAY.1 • "19 ek.14% f \A.51‘ Pita-rEc-TQA Ovec— 0 osLALAInal.) Sao os t.k M\ ( F 4\iv.cc Qma"cS. Inspector: Date: 71 c'17 11 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. (Receipt No.: I I Date: PERMIT NO. (206) 431-3670 Corrections required prior to approval. Project: 0.11 , 41 .---- Type of inspectionF Address: I "7 5r- 6 S. C . p �w�( Date called: Special instructions: Date wanted: -, A 9 q-j / R. Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 1(Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 11 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: INSPECTION RECORD Retain a copy with permit Date: -7( Date: (206) . 431 -3670 COMMENTS: I P ►C N 9tcs , G12-■P 2- IAN % SS 11.1E Lt G RA S t.. CAL_ w\ rt.c'' r r.! I r.Nr`*rit) i t sits40 5laocg 3) SA S A- IS 1- NmSS't►-)G, tErtA hl ak,_ tW► a�"5 f -L-0 4 u, w . A occ. o4 Al Special instructions: IA to D s S-rll . 51 ).i I tJ . . E. s A&C-4 itlxc--A . C IM A (. (9 ' -r147-w wA t__ P -'"Irt Gsof, , S) s.c I c_ s, xv fis 11.1 4h04.. A-P-ei:t •SOU t.n IA-AiVE' •fao wtiAx=s A- T4C.l{eb 111 714-z Gil-AV w1/4' ..) 2-" (IF 'cam s;nn.uT I is r T o Tla� sKu, . (9 mippe , yr cam • +P-.a uGN -t,J fwporA`t... r, . Proje�_�- { C..� Type o�,insption:elL) N /„ t sits40 5laocg l � (a N ' �- f '� Date called: _ 2 (� Date wanted: 1_ 2 .q _G/-- z t ! p.m. Special instructions: Requester: pH I L_ Phone No.: 575-303(0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,WN:A, gym ••\ PERMIT NO. , / n z. (206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. sector: (�, Date : / c� / $42.00$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ' s ProjeSp Fcs TypigespEwoft: p ju1/4167 legits4b c)owv.am f , t i 1 i Date called: Special instructions: fi :A 111... VI-05k Date wanted:,i in I — vd -9 1 P.m. Requester: Phone No.: INSPECTIOWRECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: Inspector: Date: V 6 ) 7 7 r $42.00 REINSPECTION FEE REQUIRED. Prior to inipection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, r eceipt No.: Date: Projeepg) MT . PCs Type of inspectionF, M AO M dgek `[ 4 . i i p p r Date called: 1 _ 7 _ 1 7 / Special instructions: Date wanted: rn. Requester: pH ' Phone No.: g. , / G INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Mu-Ls APf' itav■P0 . 0.-CKA`MC4t-- D.FTCH CI 0 r.) A S c.A-u_S FAA s a r--C -c r 604ACA �G j ( 0 . C . PC.FASZc c L t S"a w TA ALc 1k- ti.k-r Date: ,.� 1 Approved per applicable codes. Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PROJECT NAME DEPARTMENT: UILDING DI IS ON Pr. 5/ is 1 a "1 PUBLI 7 RKS COMPLETE EJ COMMENTS REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F Pani4 CczDrd. CAP`/ PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER - 0 I 3 �'I DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE N /A TUES /THURS ROUTING: PLEASE ROUTE [1 NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: APPROVED fl APPROVED W/ CONDITIONS FIRE P NTION Q PLANNIV�G MSION STRU El PERMIT COORDINATOR NOT COMPLETE NOT APPLICABLE DATE 1 APPROVED El APPROVED WI CONDITIONS Ei NOT APPROVED (attach comments) Q DATE REVIEWERS INITIAL DATE DATE 5 -I a - q� Co ecfc)n �l DUE DATES DUE DATE NOT APPROVED (attach comments) 0 (Cettificadoa of occupancy required. t, '1, k . 1:: t,`y.�Y. "x,i,t ;$F? c5:.'✓:J..ts'. «'. r*Sri".JI.W.Y�TtV- 'ic.`!!n'+`4t: ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION PUBLIC WORKS �fl 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE APPROVED APPROVED C:ROUTE -F PLAN REVIEW / ROUTING SLIP COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE E NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS IMTIAL °FT -o1L • �� �� tom- GS FIRE PREVENTION STRUCTURAL • fl NOT COMPLETE ' APPROVALS OR CORRECTIONS: (ten days) DATE 4 5 - Z APPROVED W/ CONDITIONS G CORRECTION DETERMINATION: DATE DATE DATE 5 la 97 PLANNING DIVISION PERMIT COORDINATOR DUE DATE N / NOT APPLICABLE DUE DATE 5a - �7 NOT APPROVED (attach comments) DUE DATE APPROVED W/ CONDITIONS 1111 NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) Pee Amik Coora■ riodv Cce PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97-0134 PROJECT NAME SPRINT PCS DEPARTMENT: COMMENTS REVIEWERS INITIAL BUILDING DIVISION FIRE PREVENTION ci 14411 Sta i DETERMINATION OF COMPLETENESS: (T,Th) DUEDATE 4/22/97 COMPLETE NOT COMPLETE NOT APPLICABLE El TUES/THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) DATE DATE 4/17/97 EJ PLANNING DIVISION PaT UT l e DUE DATE 5/06/97 APPROVED fl APPROVED W/ CONDITIONS NOT APPROVED (attach comments) COCi On Lel 6- 1 01011vd ti-det-97 REVIEWERS INITIAL DATE )cJf) ••■•■■•■• ■••■■•■• CORRECTION DETERMINATION: APPROVED 0 REVIEWERS INITIAL C:ROUTE-F DUE DATE APPROVED W/ CONDITIONS fl NOT APPROVED (attach comments) 0 DATE (Certification of occupancy required. 1 PLAN REVTF,W / ROUTING SLIP ACTIVITY NUMBER D97 -0134 PROJECT NAME SPRINT PCS DEPARTMENT: BUILDING DIVISION PUBLIC WORKS COMPLETE COMMENTS • L REVIEWERS INITIAL r _... . FIRE PREVENTION E STRUCTURAL fl DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE n \00\3C TUES /THURS ROUTING: PLEASE ROUTE ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F DATE DATE PLANNING DIVISION E PERMIT COORDINATOR DUEDATE 4/22/97 NOT APPLICABLE DATE 4/17/97 NO FURTHER REVIEW REQUIRED 11 DUE DATE 5/06/97 APPROVED n APPROVED W/ CONDITIONS E. NOT APPROVED (attach comments) DATE C fl DUE DATE NOT APPROVED (attach comments) (Certificadon of occupancy required. ) REVIEWERS INITIAL REVIEWERS INITIAL APPROVED C:ROUTE -F • PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION T PUBLIC WORKS D97 -0134 SPRINT PCS i DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n NOT COMPLETE COMMENTS FIRE PREVENTION PLANNING DIVISION STRUCTURAL n PERMIT COORDINATOR TUES /THURS ROUTING: PLEASE ROUTE E NO FURTHER REVIEW REQUIRED ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.) c)A9c3 L. 1 APPROVALS OR CORRECTIONS: (ten days) APPROVED APPROVED W/ CONDITIONS APPROVED W/ CONDITIONS DATE DATE CORRECTION DETERMINATION: DUE DATE REVIEWERS INITIAL DATE NOT APPLICABLE .2 v/LV) DUE DATE DATE 4/17/97 DUEDATE 4/22/97 5/06/97 NOT APPROVED (attach comments) NOT APPROVED (attach comments) (Certification of occupancy rcquired. ) :d':'diSk6 }at "CdY+n +.'.�i4 M.. -s,war t win ssifK•ivisVFbtuutvs.toAss ossRnY'sr4t ,satmeiV'. 1 iVlN1Y�h`� titwxL. HxU1S AR. I. YtTYrttMRG 'RK1lliNONtaula3RSwRNttiseso mEk.M PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0134 DATE 4/17/97 PROJECT NAME SPRINT PCS DEPARTMENT: BUILDING DIVISION FIRE PREVENTION n PLANNING DIVISION PUBLIC WORKS STRUCTURAL _ PERMIT COORDINATOR E DETERMINATION OF COMPLETENESS: (T, Th) DUEDATE 4/22/97 COMPLETE rg NOT COMPLETE NOT APPLICABLE COMMENTS () ca2.e.ij - �A I\ p e1 r s' TUES /THURS ROUTING: PLEASE ROUTE . 11 NO FURTHER REVIEW REQUIRED N ROUTED BY STAFF 11 (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL Nt. ( APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED n APPROVED W/ CONDITIONS C:ROUTE -F DATE '//Z 11 DATE REVIEWERS INITIAL DATE DUEDATE 5/06/97 NOT APPROVED (attach comments) DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0134 PROJECT NAME SPRINT PCS DEPARTMENT: BUILDING DMSION FIRE PREVENTION E PLANNING DIVISION PUBLIC WORKS ■ STRUCTURAL 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE pa_ NOT COMPLETE COMMENTS TUES /THURS ROUT) tG: PLEASE ROUTE n NO FURTHER REVIEW RE'?UIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS APPROVED n REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F R CORRECTIONS: (ten days) APPROVED W/ CONDITIONS CORRECTION DETERIYDNATION: APPROVED n APPROVED W/ CONDITIONS DATE 1 /4 - 1/ c. DATE DATE DUE DATE NOT APPLICABLE DATE 4/17/97 PERMIT COORDINATOR n 4/22/97 DUE DATE 5/06/97 NOT APPROVED (attach comments) DUE DATE NOT APPROVED (attach comments) (Certification of occupancy required. ) Project Info Project Address Si Ncr PGs Date sieve? ('1540 SOt.rYttcENTER .W 4 . For Building Department Use D';17 - 01 '3V Covered Parking Applicant Name. IRIc►t MAioes / gas Ateainrcruee Applicant Address ( ,00 MAIN, Suite 2230 g6NSts ci ry, MO Applicant Phone B8b 442 .1292 Location (floorlroom no.) Occupancy Description Allowed Watts per ft " Area in R Allowed x Area Covered Parking 0.2 W /f1 c Open Parking 0.2 W /ft Outdoor Areas 1 7 is97 . 0.2 W /ft Bldg. (by facade) ERMIT CENTER 0.25 W /ft Bldg (by perm) 7 5 W/If Note for building exterior, choose erther the facade area or the perimeter method, but not both) Total Allowed Watts • " From Table 15 -1 (over) - document all exceptions taken from footnotes Total Allowed Watts Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking 0.2 W /f1 c Open Parking 0.2 W /ft Outdoor Areas 1 7 is97 . 0.2 W /ft Bldg. (by facade) ERMIT CENTER 0.25 W /ft Bldg (by perm) 7 5 W/If Note for building exterior, choose erther the facade area or the perimeter method, but not both) Total Allowed Watts • Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Location Description Allowed Watts per 11 or per If Area in ft (or If for penmeter) Allowed Watts x 11 (or x It) Covered Parking 0.2 W /f1 c Open Parking 0.2 W /ft Outdoor Areas 1 7 is97 . 0.2 W /ft Bldg. (by facade) ERMIT CENTER 0.25 W /ft Bldg (by perm) 7 5 W/If Note for building exterior, choose erther the facade area or the perimeter method, but not both) Total Allowed Watts Location w Fixture Descnption Numbei of Fixtures Watts/ Fixture Watts (lCC IYCD ITY OF TUKWILA c (SAY 1 7 is97 . Total Proposed Watts may not exceed Total Allowed Watts for Extenor Total Proposed Watt* ERMIT CENTER t Lighting Summary LTG -SUM 1994 Washin State Nonreciiential Ener 1 994 Washington State Nonresidential E'+ergy Code Compliance Forms Com•liance Form April 1994 Project Description I ❑ New Building ❑ Addition j ii, g 4lteration Compliance Option Prescriptive ❑ Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plans ) Alteration Exceptions (check appropriate box) ❑ No changes are being made to the lighting ❑ Less than 60 % of the fixtures are new, and installed lighting wattage is not being increased Maximum Allowed Lighting Wattage (Interior) W. Foe. r €seIPnvv Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Maximum Allowed Li Min Wattage (Exterior Proposed Lighting Wattage (Exterior) May not exceed Total Allowed Watts for Exterior) Use' LPA' (W /ft Use' LPA (W itt') Painting, welding, carpentry, machine shops 2.3 Police and fire stations 1.2 Barber shops, beauty shops 2 Atria (atriums) 1 Hotel banquet/conference /exhibition hall" 2 Assembly spaces', auditoriums, gymnasia', theaters 1 Laboratories 2 Process plants 1 Aircraft repair hangars . 1.5 Resta rs Cafeterias. fast food establishments 1.5 • Retail A' Factones, workshops, handling areas 1 5 Ret 10 nking Gas stations, auto repair shops' 1 5 Locker and/or shower facilities 0.8 Institutions 1 5 Warehouses ", storage areas 0.5 Libraries 1.5 Aircraft storage hangars 0.4 Nursing homes 1 5 Parking garages s.ii s''°' t532 Wholesale stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools buildings, school classrooms, day care centers 1.35 Common area, comdors, lobbies (except mall concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office buildings, office/administrattve areas in facilities of other use types (including but not limited to schoots, hospitals, institutions, museums, banks, churches) 7 ' 1 1.2 Prescriptive Spaces' Occupancy ❑ Warehouses, storage areas or aircraft storage hangers ❑ Other Qualification Checklist Nole. If occupancy type Is'Oiher" and fixture answer is checked. the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified. do LPA Calculations. Lighting Fixtures: • • , ❑ Check here if at least 95% of fixtures in the space meet all four criteria: • , 1 Fixtures are fluorescent, non - lensed, with only one or two lamps, and •.2. Lamps are T -5, T -6, T -8 or PL, and 3. Lamps are 5 -50 Watts, and 4. Ballasts are electronic ballasts Lighting Summary (back) LTG -SUM 1994 Washin•to tate Nonresidential Etter • Code - n•liance Form 1994 Washington State Nomestdential Energy Code Compliance Forms April 1994 Table 15-1 Unit Lighting Power Allowance (LPA) for Interior Lighting Footnotes for Table 15-1 1. In cases in which a use is not mentioned specifically. the ( iii► Power: allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. Sec Section 1512 I'or exempt areas. 2. The watts per square tool may be increased. by two percent per foot of ceiling height above twenty feet. unless specifically directed otherwise by subsequent tootnotes. 3 Waus per square !hot of room may be increased by two percent per toot of ceiling height above twelve feet. 4. k r all other spaces. such as seating and common areas, use the ( ;fir light Power Allowance for assembly. 5. Waits per square foot of room may be increased by two percent per toot of ceiling height above nine feet. 6. Includes pump area under canopy. 7 In cases in which a lighting plan is submitted for only a portion of'a floor, a Unit Lighting Power Allowance of 1.35 may he used for usable office floor area and 0.80 watts per square toot shall be used for the common areas, which may include elevator space. lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. R. For the lire engine room. thc Unit Lighting Power Allowance is 1. watts per square toot. l'or indoor sport tournament courts with adjacent spectator seating. the Unit Lighting Powcr Allowance for the court area is 2.6 watts per square foot. Itt For both Retail A and Retail B. light I'or tree- standing display. building showcase illumination and display window illumination installed within Iwo feet of the window are exempt. Retail A allows a Unit Lighting Power Allowance of 1.0 watts per square toot. Ceiling mounted adjustable tungsten halogen and 1110 merchandise display iiluminaries are exempt. Retail H allows a Unit Lighting Power Allowance 011.5 watts per square toot. including all ceiling mounted merchandise display computing the interior Unit Lighting Power Allowance. as thc floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in tbotnote 2 applies only to the floor area nol covered by racks. 4 Lighting Permit Plans Checklist .. LTG-CHK 1994 wasnington State Energy Code Comobanee Forms • ProiectAddress .,. . ,.. 'Date ., , „ ..... . ., The following inforrriation is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. . . • ' . _ . . ... . Applicability 1 (circle one ) .j ... Code .. Section : . , ,, ,.. ., . , Component .. . ,, .. , — • , Information Required' • - - - Location 'on Plans Building Department .'.. , . Notes'.-.. LIGHT! ,CONTR L .(Section 1513) , .. , , • yes no n.a. 1513,1 ' Local control/access . Schedule with type. indicate locations yes no ' n a. 1513.2 Area controls Maximum limit per switch 1513 3 , Daylight zone control Schedule with type and features, indicate locations yes no .' n.a. .. ' vertical glazing 1 ' Indicate vertical glazing on plans yes no n.a, . , . overhead glazing Indicate overhead glazing on plans yes .. no n.a. 1513.4 - Display/exhib/special Indicate separate controls .- . 1513.5 Exterior shut-off Schedule with type and features. indicate location • . yes , no ..n.a, .. (a) timer w/backup ' Indicate location yes. no n.a. , • (b) photocell. - Indicate location . . , 15116 - Inter; auto shut-off Indicate location . • yes no ,:n.a. - 1513.6.11. (a) occup. sensors. Schedule with 1pe and locations . . yes . no n.a. " 1513.6.2 (b) auto. switches . Schedule with'type and features (back-up, override capability), ,. Indicate sin of zone on plans LIGHTING 1520-22 or 1530-32) yes no . 1 Lighting Sum. Form Completed and attached. Schedule with fixture types. J lamps, ballasts. watts per fixture ' ELECTRIC MOTORS (Section .1511) ••, . . . yes no n.a, • ,...." ' Elec motor efficiency ", MECH-MOT or.Equtpment Schedule with hp, rpm, efficiency . " . . _ 1994 W.ahirig 9, State Nonresidential,Energy CodeQompIiance Form If no " is.circied lor quest on, prov e expl • • • 19942.Washingto _State Nonresilentiat Energy Code Compliance Form Lighting Permit Plans hecklist 1904Wasnington State Energy Code Compliance Forms Lighting - General Requirements 1513 Lighting Controls 1613.1 Local Control and Accessibility: Each space. enclosed by walls . or ceiling-height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit. to personnel'occupying or using the space. „ • Exceptions: The following lighting controls may be centralized in • . . remote locationi: • , . , 1. Lighting controls for spaces which must be used as a whole. 2; Automatic controls.' ; . 3. Controls requiring trained operators 4. . COntrols for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a twenty ampere circuit loaded to not more than eighty percent. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. • Exceptions:. . • . 1. • ., Industrial or manufacturing process areas, as may be required for production. 2; . Areas less thin five percent of the building footprint for footprints over 100,000 ft ,•. 1513.3 Daylight Zon All dayfighted zones defined in Chapter 12. both under overhead glazing and adjacent to vertical glazing,. shall be provided with individual controls, or daylight- or occupant-sensing automatic controls, which control the lights independent of general area lighting. 1513.4 Display, Exhibition, and Specialty Lighting Controls: All display, exhibition, or specialty lighting shall be conbolled independently of *general area lighting. 1613.6 Automatic Shut-off Controls, Exterior: Exterior lighting not intended for 24-hour continuous use shall be automatically switched by timer, photocel, or a combination of timer and photocel. Automate time switches shall also have program back-up capabilities; which prevent the loss of program and time settings fol at least 10 hours, if power is , 1513.6 Automatic Shut-Off Controls, Interior: Office buildings greater than 25,000 Wand all school classrooms shall be equipped with separate' automatic controls to shut off the lighting during unoccupied hours. Automatic controls may be an occupancy sensor; time switch, or Other device capable of automatically shutting off lighting. Exceptions; .••• • • . • • 1. .'; Areas that must be continuously illuminated, or illuminated in a manner requiring manual operation of the lighting. 2. . :Emergency lighting systems. • . 3. ' Switching for industrial or manufacturing process facilities as • may be required for production. • , i 613.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area; no more than 30 minutes alter the area has been vacated. •1513.6.2 Automatic Time Switches: Automatic time switches shall have . a minimum 7 day•clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut-off'. feature, • , which turns off Woods for at least 24 hours and then resumes normally scheduled Operations. Automatic time switches shall also have program ., back-up capabilities. which prevent the loss of program and time settings for at least 10 hours, if power istnterrupted. • • • • Automatic time switches shall incorporate an over-ride switching device. which: • • . a, , is readily accessible; ' . • b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the - area being illuminated is annunciated; ' • c. • is manually operated; d.. • allows the lighting to remain on for no more than two hours . when an over-ride is initiated; and ' e. controls an area not exceeding 5,000 ft or 5 percent of • footprint for footprints over 100,000 ft', whichever is greater. Apnl. 19IM • . . LIGHTING F I XTURE SCHEDULE TYPE MFR. t MODEL NO. VOL FIXT. LAMPS DESCRIPTION '• ' A . JUNO ' #TC2-2413-120V . • • 120 4c1 (1)15W PLT/30 6" DIAMETER RECESSED DOWNLIGHT'INITH BLACK BAFFLE AND WHITE TRIM RING. •FURNISHED AND INSTALLED BY, ' ELECTRICAL CONTRACTOR. REFERENCE KEYNOTE 2, SHEET El. B JUNO. ' ' ' ; • - - ' #TC20-659C-120V ' . .. . 120 5 (0 ,1514 PLT/30 5" DIAMETER RECESSED DOWNLIGHT WITH BLACK BAFFLE, WHITE TRIM RING, AND GIMBAL. FURNISHED AND INSTALLED • BY ELECTRICAL CONTRACTOR. REFERENCE KEYNOTE '2, SHEET El. C • • . JUNO .-: , #V65 • ' . 120 5 (1) 5014 PAR3OL/HAL/ ' NFL30 OPEN BACK SPOTLIGHT. SEE DRAWINGS LAMPHOLDER . QUANTITIES.. FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 17 JUNO . . . , '. #TMBX261A1H-1-IPF-120V . 1A4/ #T431A1H '120 I 10 1) #PL-G 261AI/21 MONO-POINT FLUORESCENT WALL WASHER AND. HIGH POWER . 'FACTOR BALLAST. ' FURNISHED ANP INSTALLED BY ELECTRICAL CONTRACTOR. E DUAL LITE . ' ItEZ-2-120V 2T1 3 (2) 1.21AI SEALED BEAM INC. IN/ FIXTURE EMERGENCY LIGHT WITH THIN ADJUSTABLE HEADS AND • SEALED LEAD, CALCIUM' BATTERY. FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. F . . METALUX ' '• #2G440A-LE3 . 211 16 (4) F32T5/ TL641 2' X 4' (4) LAMP FLUORESCENT FIXTURE WITH Al2 VIRGIN ACRYLIC LENS. • G JUNO . . ,. . . #TMI3X26BLI-HPF-120V :' IN/ #T3IBL . • 120 p 1) #PL-C 2614'21 COMPACT FLUORESCENT TRACK HEAP AND HIGH POWER FACTOR BALLAST.' FURNISHED AND INSTALLED BY ELECTRICAL' CONTRACTOR. • , • JUNO.. #TMBX26INH-HPF-120V 14/ #T3IWH . 120 4 ' I) #PL-C 261A1/21 COMPACT FLUORESCENT TRACK HEAD AND HIGH POWER FACTOR BALLAST. FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. •T16. JUNO (2) (1)#V2021WH 6 (1)#V2023141-1 120 - -- 16-0" LONG LIGHT TRACK FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ' Tas JUNO (1)#V&BL, (1)#V202IBL 120 - -- 6'-0" LONG LIGHT TRACK FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. T51A1 • JUNO (I)#V&WH, (1)#V2021WH 120 - -- 5'-0" LONG LIGHT TRACK FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. X DUAL LITE . KSR-EP 2T1 3 INC. IN/ FIXTURE SINGLE FACE UNIVERSAL MOUNT. EMERGENCY EXITLIGHT. . FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ; =' . • • LleHT FIXTURE SCHEDULE NO SCALE RECEIVED CITY OF TUKWILA MAY 1 2 1997 PERMIT CENTER 0031071 „ :4141q1 PROJECT NAME: SUBMITTED TO: Bldg. CITY OFc- JKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL DATE: PLAN CHECK/PERMIT NUMBER: Df7 ` 0 134 PROJECT ADDRESS: 17 G O 0 / -e/ l -ter CONTACT PERSON: ttt Mk PHONE: east. 6 4z. 1 29 2 REVISION SUMMARY: SUI NACrrrp LTS Reg Pa/Ia i COMMENTS AK.o46 CO/ P$`ll UC TIN , f xrve& st,klcDVC.E sttji1P F xTU2c' CDUNT. SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. Planning Fire RECEIVED CITY OF TUKWILA Public Works 3/19/96 MAT 1 2 j 19997 PERMIT CENTER /eat CITY USE ONLY April 28, 1997 Mr. Rich Majors Rees Architecture 1100 Main, Suite 2230 Kansas City, Missouri 64105 Dear Mr. Majors: SUBJECT: CORRECTION LETTER #1 Development Permit Application Number D97 -0134 Sprint PCS 17540 Southcenter Py This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Building Division. At this time the Planning Division, Public Works Department and Fire Department have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, l'6,86te i—e%6&e 5'01 Kelcie J. Peterson Permit Coordinator Enclosures File: D97 -0134 City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431 -3670 • Fax (206) 4313665 • DATE: PROJECT NAME: APPLICATION NO. : PLAN REVIEWER: BUILDING DIVISION COMMENTS April 24, 1997 • Sprint PCS tenant improvement permit application D97-0134 Ken Nelsen, Plans Examiner (206) 431-3670 • There are no significant Building Division life safety concerns on the general project. However, regardless of the submitted electrical plans and specifications a lighting budget must be submitted to show conformance with Washington State Energy Code 'Chapter 15. Attached is the lighting portion of the State compliante form, other formats may also be acceptable. The architectural lighting plans may need to be revised to reflect the wattage limitations on the compliance form. :15 April 23, 1997 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Fire Department Review . Control # D97 - 0134 Re: T.I. at Sprint PCS, 17540 Southcenter Py Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or. obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number Thomas P. Keefe, Fire Chief halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 04,4ft V44.0 City of Tukwila Page number 3 Fire Department Thomas P. Keefe, Fire Chief required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level,. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) 7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 City of Tukwila Fire Department Page number 4 P _w 9. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submi to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required .fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 Page number City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 TFD file ncd City of Tukvvila John W Rants, Mayor Fire Department : Thomas P Keefe, Fire Chief The Tukwila Fire':Prevention Bureau Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S7S -4404 • Fax (206) 575-4439 APR -I6 -97 12:37 Frops:Sprint PCS Contracts LEGAL DESCRIPTION 8165593920 PARKWAY PLAZA SOUTH That portion of the southeast quarter of the southwest quarter and of the southwest quarter of the southeast quarter of Section 26, Township 23 North, Range 4 East, Willamette Meridian, and of the northwest quarter of the northeast quarter and of the northeast quarter of the northwest quarter of Section 35, Township 23 North, Range 4 East, Willamette Meridian, King County, Washington, described as follows: Beginning at the northwest corner of the northeast quarter of said Section 35; Thence south 87 °44'08" East along the north line of said northeast quarter a distance of 140.16 feet to the true point of beginning; Thence South 02 °24'12" West parallel to the west line of said north- east quarter a distance of 894.23 feet to the north line of the south 430.00 feet of the northwest quarter of the northeast quarter of said Section 35; Thence North 87 °50'09" West along said north line a distance o1.140.16 feet to the east line of the northeast quarter of the northwest quarter of said Section 35; Thence North 87 °50'57" West along the north line of the South 430.00 feet of said northeast quarter of the northwest quarter a distance of 177.29 feet to a point 6.00 feet distant northeasterly, measured at right angles, from the easterly margin of the Mess Brothers County Road No. 972; Thence North 11 ° 59'33" West along a line 6.00 feet distant northeasterly, measured at right angles, from said easterly margin a distance or 1024.61 feet; thence South 88 °47'35" East a distance of 570.04 feet to a point on a line which is North 01 °12'25" East a distance of 108.77 feet from the true point of beginning; thence South 01 ° 12'25" West a distance of 108.77 feet to the true point of beginning. RECEIVED CITY OF TUKWILA APR 1 7 1997 PERMIT CENTER T -013 P.02/05 Job -588 /1//C sod . / cam._. EXHIBIT A PLEASE INITIAL LESSEE labor and industries REFERENCE SYMBOLS ® Detall Sectton G Nell T9,, wax Interior Belot., -� �- Door to be Removed Noll to be Remrn•ed Exstag Door Erbt.Ma Y?cll Nc Daw e Door R rnber E. Room ri<anc I lol I Room Number No-o1 Gctii g Elevation O Construction Nate Rnlsn Dcsionctton 13M-D154 GENERAL NOTES GOB ZEVIEP riATA HRDfG GOLF OGQJPANCY ea `RC P SCAIPEFiX2TA OOCiP.vir LOAD 3135 .114€ 1944 380 3412 5F_ sa N6 REVISIONS: DRAIA1 I NO INDEX ARCHITECTURAL SHEET AI - TITLE SHEET SHEET DI - DEMOLITION PLAN SHEET A2 - FLOOR PLAN SHEET AS - RE=L ECiW CEILING PLAN SHEET A4 - ELEVATIONS SFicET AS - DETAILS St= Ab - SPECIFICATIONS MECHANICAL SHEET MI - PLUMBING FLOOR PLAN SI-EET M2 - FI /AC FLOOR PLAN SHEET M3 - SPECIFICATIONS AND SGFEDULES ELECTRICAL SHEET EI - LIGHTING AND POVER PLANS SHEET E2 - COMMUNICATION FLOOR PLAN 51-HFET E3 - SPECIFICATIONS. SCHEDULES, AND DIAGRAMS COMMUNICATIONS SHEET GI - ELECTRICAL COMMUNICATION PLAN SHEET G2 - SPECIFICATIONS t the Plan Check aPP 5 ect to a that s and orn2e the sand o coo ry a P lans does d e or ordinanc' .:� o.,:I °deed. adopted tractor's copy PP'J l' C.: BY Date : 'L -r - = !_ Permit No SPORTMART 1 SITE FLAN SPRINT PCS FARKWAtY PLAZA SOUjHGVNTER Pp.R WA:( ac11 *O I SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 SEPARATE PERMIT RE USED BCRANI ELECTR ❑ PLUMBI 0 GAS PIPING OP DI IO BUILDIN THE EON RECEIVED ® APR oP Tull 997 AP E ? 1997 PERMIT CENTER REFS JAMES A. LICHTY ARCHITECT ARCHITECTVRE Al 1107 UM STMT. S18T8 8890 KANSAS CITY. MO 64106 816 - 858 -1808 FAX 848 -1078 GENERAL NOTES PLAN NOTES STAMP' ` G-°° --°- -� rp ,� ` ( ° p q� _ = >?s.F'I�1116 '411t. _ i :i ..*, I. REMOVE ALL BRANCH DUCTWORK FROM THE MAIN DUCTWORK AND SEAL THE CONNECTION POINT AIRTIGHT. 2. ALL CONTROLS, INCLUDING THERMOSTATS, VALVE, PUMPS, WIRING, SMOKE DETECTORS, TO REMAIN. 5. NOT L/SE7 4. WATER (=EATER AND ASSOCIATED PARTS SHALL REMAIN 5. ALL ROOF DRAIN PIPING TO REMAIN 6. ALL EXISTING LIGHT FIXTURES, OUTLETS, AND SWI T..HES WITHIN INTERIOR SPACE ARE TO BE ABANDONED AND RE -iOVr, EXCEPT FOR THE FOLLOWING= - EXIT LIGHTS O N ar I/5ID Z. NOT MED O REMOVE EXISTING CABINET_ PATCH WALL AS W.GIRRED C. - SELF CONTAINED EMERGENCY EGRu.�-5 LIGHT - ELECTRICAL ONttrLTiONS TO HVAG UNITS) - EXTERIOR LIGHTING AT ?FRONT AND REAR OF SPACE - DUPLEX CONVENIENCE RECEPTACLES AT ROOFTOP EQUIP. - ,i1N..TiGN BOXES) FOR 516Ns - 1. ABANDON A• REMOVE ALL BRANCH CIRCUIT RAGE Y5, GONn�UGTORS, BOXES, ETC_ W WIN LEASE SPACE BACK TO 11-E PANELBOARD. BRANCH CIRCUITS FOR ITEMS INDICATED TO REMAIN (ITEMS ABOVE) SHALL BE REI^llRED AS NECESSARY SQ AS TO REMAIN ENERGIZEM AFTER DEMOLITION 15 COMPLETE_ S. EXISTING FIRE ALARM SYSTEM DEVICES, DETECTORS, AND ASSOCIATED WIRING TO REMAIN. PROVIDE TEMPORARY MOUNTING FOR DEVICES LOCATED IN REMOVED WALLS OR CEILINGS. 1 0 i 0 176r,0114 ( , " DEMO FLAN � I /4` =I —o NOTES= ALL WALLS SHOWN DOTTED SHALL BEREMOVED_ PATCH AND PREPARE ADJACENT CONSTRUCTION AS REGUIRED TO RECEIVE NEVI FINISHES IN AREAS Y WALLS ARE. INDICATED TO BE REMOVED, REMOVE THE EXISTING CEILING GRID_ REFER TO GENERAL NOTES FOR INSTRUCTION FOR CEILING MOUNTED EXISTING.: TOILET TO. REMAIN, INCLUDING ALL PLUMBING FIXTURES, CEILING GRID, AND LIGHT FIXTURES_ REMOVE ALL FLOORING, EVEN IN AREAS SCHEDULED TO REMAIN. PATCH AND REPAIR SUBSTRATE AS REQUIRED TO RECEIVE NEW FINIO EP. RETAIN 6 GATT INSULATION ABOVE EXISTING CEILING, INSULATION WILL BE REUSED ABOVE NE:W CEILING_ L r — T 1 SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 REOEIVED GTY OF TUKWILU APR 1 7 1997 PERMIT CENTER I — , j WALL TYPE 1 1/2 " =1' -0" 11 I 2)' AGC.LST. CEILING SY AT 4' -3 2'X4' ACC/UST. CEILING SYSTEM AT 9=2" 3 1/2" (25 GA) MT_. STUDS b I6 OG. 5/6" GYP. BD. BOTH SIDES BAS-E - SEE FINISH NOTES CD FLOOR FINISH PLAN I/16" = I -0" GENERAL NOTES I. REFERENCE ELEVATORS ON SHEET A4 FOR WALL FINISHES, UNLESS NOTED ON THIS ILI IQT. 2. DOTTED LINES INDICATE FIXTURES E CEILING CLOUDS WHICH ARE MR-NISI-EL) AND INSTALLED BY THE CONSTRUCTION MGR (N.I.c) SUPPORTS FOR CLOUDS BY GENERAL CONTRACTOR PLAN NOTES 0 0 PROVIDE AND INSTALL 5/16" X V2' X I/16" SS. ANGLE TO PROVIDE EDGE AT CERAMIC TILE. FINISH EXPOSED EDGE TO MATCH HEIGHT OF INSTALLED 11F PRIOR TO INSTALLING CARPET. PROVIDE AND INSTALL VINYL TRANSITION ADAPTOR BETWEEN CARPET AND VINYL FLOORING, AS MAN. FACTURED BY JOHNSONITL, MODEL .CD -XX-S, COLOR *20 CHARCOAL, WITH APPROPRIATE TRACK SASE. 0 O O 0 7 0 0 PLAN NOTES EXISTING DEMISING WALL - I HOUR FIRE RATrP ILO" W117E HALL - SEE ENLARGED PLAN 2/A5 AND DETAIL 6 /A5_ coti FR.Am NG UP TO STRUCTURE AND STOP GYP. BD. 6' ABOVE GELLING. DROPPED 1 ADER - 5)= DTI 5 /A5 FLOOR F FO. OUTLETS - Sri ELEG. DRAWINGS SAFE - BY CONSTRUCTION MANAGER AND INSTALLED BY CONTRACTOR - PROVIDE ANCHOR BOLTS PER DETAIL 1 /A5_ WALL MOUNTED FIRE EXTINGUISHER - FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR MOUNT 5' X 5' X 1/2 PLYWOOD (HORIZ) ON WALL 6" A.F.F. PROVIDE AC FINISH GRADE PLYWOOD TO MEET LCYAL CODES Q l�I�lili 3'_4" 11' -2" • 8 ( FLOOR PLAN s- GINSJ_ ° DOOR TYPES I/4 ° =1' -0" FLOOR FINISHES EXISTING EXPOSED CONCRETE NAL L FINISHES WAILS TO BE TAPED AND SAND! ONLY ALL WALLS TO BE PAINTED, E3LIDVELi', 501 63/01 2 S.G.YYD_ VINYL WOOD PLANK BY "WALLY WOOD ", ° -106 rFRATEtJ"N MAPLE CARPET BY PRINCE Six s1 TELL* OLOGY, "AN/04E', COLOR TO BE SF =GTED BY Ti-5 ARC.Hfl LT CARPET BY PRIN S1,4.1 TECHNOLOGY, NP RH AL', DOLOR TO BE SSEGi 7 BY THE A G111 T_ VINYL coMPosF'P10N TILE SY 'AZROCK ", COLOR 3V -666, "SHALE PORGEGALN CERAM'C TILE BY CRO:SVILLE CERAM1GS', "CROSS COLORS', COLOR .A360-ONYX UP IL ALL DOORS, FLARDINA1 P./RMSFE7 INSTALLED BY 433€RAL CONTRACTOR FINISH NOTES DOOR NOTES 0 O LJ ALL WALL FINIS NOiB, ON SS EVATIONS, RE 5H1 A/4, UNLESS NOT NO= ON TH15 PLAN UNDER "WALL FTh 1SFES'. 2. ALL WALLS TO HAVE RUBBER COVE BASE. ALL RUBBER SASE BE 'ROFFE', COLOR _, ° 15 LACK BROWN ". ALL SASE TO $t n,IRNIBE3, CONTRACTOR, INSTALLED BY CONTRAGTOR_ 3. ALL FLOOR FINV,HIES TO BE PROVIDED BY 11-5 CONTRACTOR ---GEPT FOR GAS B E C. CONTACT FOR VINYL 14005 FLANK a_OOR WV NATIONAL PRICING IS. WONDER WORKS r.F. AMERICA - GOHTALT WALLY, GRACE OR JOYCE BROOKLYN NAVY YARD, BUILDING *292, SUITE 402 BROOKLYN, NY 11205_ PHONE. 1 -600- 336 -1029_ EXISTING DOOR TO REMAIN - PROVIDE NEW CONTACT FOR SECURITY SYSTEM. NOT USED EXISTING DOOR TO REMAIN - PROVIDE NEW CONTACT FOR SECURITY SYSTEM AND PEES' HOLE FURNISHED AND INSTAL 1 Fr, BY CONTRACTOR - HAGAR 1155 OR EQUAL. NEW 5' X 7' X 13/4" SOLID CORE WOOD DOOR WITH 2" HOLLOW METAL FRAME WITH DOOR I T1, I. PROVIDE HARDWARE GROUP G - PER THE SPECIFICATIONS. NEN 5' X 1' X 1 5/4" SOLID CORE DUTCH TYPE HOOD DOOR WITH 2" HOLLOW METAL FRAME AND DOOR TYPE 2. PROVIDE HARDWARE GROUP B - FER THE SPECIFICATIONS. PUSH BUTTON KEYPAD LOCK FURNISHED SY CONSTRUCTION MANAGER AND INSTAI 1 Fn SY CONTRACTOR STAMP PERMIT CENTER NOT USED \q 5i1LLU n,ti 1110 EXISTING DOOR 14/ FRAME TO BE RELOCATED FROM EXISTING TOILET. PROVIDE HARDWARE GROUP A. NEW 3' X T X 13/4" SOLID CORE WOOD DOOR WITH 2" HOLLOW METAL FRAME WITH POOR TYPE I. PROVIDE HARDWARE GROUP A - PER THE SPECIFICATIONS. PROVIDE PRIVACY LOOK IF NEEDED. NEW 5' X T X 13/4" SOLID GORE WOOD DOOR WITH 2" HOLLOW METAL FRAME WITH DOOR TYPE I. PROVIDE HARDWARE GROUP G - PER THE SPEGIFIGATIONS. NEW 5' X 1' X 13/4" SOLID CORE WOOD POOR WITH 2" HOLLOW METAL FRAME WITH DOOR TYPE I PROVIDE HARDWARE GROUP A - PER THE SPEGIFIOATIONS. NEW 5' X T X 15/4" SOLID GORE WOOD DOOR WITH 2" HOLLOW METAL FRAME WITH DOOR TYPE I. PROVIDE HARDWARE GROUP A - PER THE SPECIFICATIONS. RECEIVED CCTV bF TUKSLA APR 17 19997 SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA MARCH 1997 tx1_ O1L1 DO I IE LINES INDICATE FIXTURE AND CEILING CLOUDS WHICH ARE FURNISHED AND INSTALLED BY THE CONSTRUCTION MANAGE - R. (N.I.G) SUPPORTS FOR CLOUDS BY COAL CONTRACTOR 2. SIESMIG BRACING REQUIRED IN LOCATIONS WITHIN SIESMIC ZONE 2, 3. E 4 ONLY IN OTHER AREAS DISCARD DTIS. 2, 3, e 4 ON THIS SHEET RE- INSTALL 6" BATT INSULATION ON TOP OF NE N 2X4 LAY-IN CEILING. LIt € OF SOFFIT ABOVE TO MATCH LINE OF FLOOR PATTERN .OYi PLAN NOTES II'-0" NFERENGE 10061 TORAGE 008 I ci s — ? 3 - 0 2' -0" ci' -2" EXIST. TOILET 1004 ERE K 00 1� [ IU i FFIC i �I ooi ` O I l^IO 2 11 I■[� I` 11 I� ! NIi I / j %I L A -1111 MENTOR 1005 O 2 \ SIESM1C BRACING LOCATION 1/4" =1'-O GENERAL NOTES GYP_ BD.:F,_ADER G 9'-G" A.F.F. - RE: DTL 5 /A5 ( O ' CENTER CLOW' FURNISHED AND INSTALLED BY 114E CONSTRUCTION MANAGER - CONTRACTOR TO PROVIDE (6) THREADED RODS S OR":}3J FROM TI-E STRUCTURE ABOVE RE= DTL. 5/A3. CONSULT GOAD FURNISHED AND INSTALLED BY THE CONSTRUCTION MANAGER - CONTRACTOR TO PROVIDE (4) THREADED RODS Si.PPORTED FROM THE STRUGTJRE ABCVE R?=- DTI- 5 /A3. CEILING FINIS' ES FINISH NOTES 1/4' =1 REFLECTED CEILING FLAN 0 SIBSMIG BRACING LOCATION I/4 " =I '-0" PGOUSTTCAL COLIN& TILE AND GRID TO BE BLACK (FACTORY F11415 1-0 ACOUSTICAL LAY -TN TITS AND SON GRID DOLOR TO BE SPECS EXISTING GEILINS TO RAIN_ NOT USs. GYP. BD_ SOFFIT. PAINT - GLIDDEN W YY631060 NOTE: ROTATE ANGULAR FITTING 9O DEG_ WHEN BRACE IS 'P_ TO UNISTRUGT CHAN. AT ROOF AND CLOUD. SIESMIG SRAC1NO DETAIL 3/4 " =1 '-0" EXISTING CEILING TO REMAIN PAINT WHITE 112' -O" UNISTRUGT CHANNEL c ROOF FRAMING ANGULAR FITTING \ TYP. AT EA. END - - UNISTRUCT CHANNEL BRAGS FOR SIESMIC Z2" DI 2, 3, b 4 ONLY /2 DIA. UNIROD UNISTRUGT CHANNEL IN CLOUD - N I.G) SPRINKLER CLOSET 1 ooa 1 OPEN TO STRUCTURE ABOVE Gi' -2 EXISTING ROOF 0111W40111010MINIE S 2" D NUT. W/ SPRING NUT. SIMPSON LTT2O TENSION TIE ATTACH TO JOIST W/ 4-I6d rV' MIN. GUT TIE LEG AS REM, TO -I/2' DIA. UNIROD FIT I -JOIST DEPTH. THREADED ROD (MAX. 2 PER GHAN.) REr Dm D�n�ITA SPRINT PCS APR i 7 i997 PERMIT CENTER PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 P2000 UNISTRUT CHANNEL - 8' -0" MAX. SPAN TYP. GE I L I NO CLOUD SUPPORT 3/4 " =1 ° -0" REFS JAMS A. LICHTY ARCHITECT ARCHITECTSTRE A3 1100 WI 0011T, slims 5450 KANSAS CITY, YO 84106 010 -642-120 TAX 64E -100 RECEIVED CRT OF TUKWILA APR 1 7 1997 PERMIT CENTER SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 REFS JAMES A. LUCHTY ARCHITECT ARCHITECTVRE A4 1100 vaffi STEM SOBS seso KANSAS QTY, MO 84106 810- 818 -1805 FAX 848 -1878 GENERAL NOTES PLAN NOTES FINISH NOTES � � I . VI . -. J WALL FINISHES I. �, 3. 4. v 0 .IUNCTION BOX FOR HIRING LIGHT SOXES O 5F U T {1I _ FROyIDE BLOCKING O BASE u,11T (FIxiT7P" SPRINT LOGO - FURNISHED AND INSTALLED BY O SP G(iti.'f'1d1CTfON MANAG? =R - O EX;">r�30R 5: - ?tiA .- U?�:Lt�D Ale, SIONAGE CONTRACTOR. (F.I.C.) 0 © ALL HALLS TO BE FARMED 'GLIDDEN' .5OYY bb / 041 • FAINT •GLIDDI3i 05 /0am' o FAINT �gl• 36OY1f 83/�b2 VINYL Y�S.LCOVi321NG, YI 1 COLOR 'APEN' © V.`NYL VI GRTEx WOK COLOR 6REYST ' L Au_ i4AL LGOVERIN6 AND RUBBER BASE TO SE FURNISHED E INSTALLED ? f THE GON7RAGTOR THE CONTACTS FOR TtT i COVERING ARE AS FOLLOIIS SIGN TO BE CHANNEL BOX LET ERS INDIVIDUALLY MOUNTED TO HE STONE FASCIA. POWER TO BE THROUGH WALL_ AND WIRED TO TENANTS TIMER. . LIGHT SOURCE TO BE NEON. NOT USED SPECIFICATIONS AND DETAILS TO BE COORDINATED BY SIGN MANUFACTURER, MANUFACTURER, LANDLORD, AND TENANT. SIGNAGE TO BE SUPPLIED AND INSTAI 11=n BY SIGN CONTRACTOR. (N.I.G) COORDINATION OF ELECTRICAL PREPARATION BY GENERAL CONTRACTOR. VIGRTcX AKry KnrSeal YRODLY7PRODUCTS. -KIM oR ToB1N - c GGRA7IVE SERVICES - 641 LAKE 51KCC 1, SUITE 101, CHICAGO, LL. 60661 F14.600-55-2111 ! WOl-F 6l7RDON fROD'JG75 - SHANNON - IN7ERVV0`�ET! DESIGNS -.3 SOUTH NEWS ST. LOUIS, MO 63108 F1-6514-531-6200_ _ E NATIONAL W6413272. (TH IS NUMBER mar B` GIVEN TO RECEIVE NATIONAL f'RICKS.) O RUBBER 5AS SzOPPE', COLOR ?43 SLACK BROYfr Q VINYL MALLCOVERING, KORO EAL, "T AZZO', DOLOR 'CHARCOAL' Q VINYL NIALLCOVERIN , IKOLFG d', •415.1F.5272 I { I I --1=34=i—= _, L i 1 11 -- - -- J ELEVATION -FRONT FACADE . NOT USED L +: - SEE DETA� 6 /FS (SR.0 FOR t�i0HT 1D T-IP I/4 " =I' - 0" ,„,____,/ 1f4 ° =1 "-G' CUR= WALL s�r ota� ' Q m BEYOND SOFFIT �© O I C.OHTiP1T 874SH "Cr —.= T L A� ` \ _ _M __f MI AROUND HIS SIDE OF fi IN E R WALL 6 °_ OF THIS SIDE TO BE 'K'. 1 =II Illn _ I I ELEVATI 1 1 --0 - RETAIL AREA - RETAIL AREA 1/4 " =1' -0" (1) ELEVATION I/4 ° =1' -0° 2 -6 2.-6" I,- L ® -__m�® -4 -m - O _ 0 _ O O {� O O a Y \ —_ t- _-- -_ —_ f -- ' 1 ry L_J L —J L —J : N V -1 v2° 7a--r-3i k f0 , I„ -0,T2, -0,! , t c�NC ^r pp i� 0 ELEVATION - RETAIL AREA 0 \ \9S /2, CD ELEVATION - RETAIL AREA 4-1..0151.1 RECEIVED CRT OF TUKWILA APR 1 7 1997 PERMIT CENTER SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 REFS JAMES A. LUCHTY ARCHITECT ARCHITECTVRE A4 1100 vaffi STEM SOBS seso KANSAS QTY, MO 84106 810- 818 -1805 FAX 848 -1878 GENERAL NOTES PLAN NOTES FINISH NOTES STAMP :' d o e e _, a, . VI . -. J WALL FINISHES I. �, 3. 4. SIGNAGE: 0 .IUNCTION BOX FOR HIRING LIGHT SOXES O 5F U T {1I _ FROyIDE BLOCKING O BASE u,11T (FIxiT7P" SPRINT LOGO - FURNISHED AND INSTALLED BY O SP G(iti.'f'1d1CTfON MANAG? =R - O EX;">r�30R 5: - ?tiA .- U?�:Lt�D Ale, SIONAGE CONTRACTOR. (F.I.C.) S7 © ALL HALLS TO BE FARMED 'GLIDDEN' .5OYY bb / 041 • FAINT •GLIDDI3i 05 /0am' o FAINT �gl• 36OY1f 83/�b2 VINYL Y�S.LCOVi321NG, YI 1 COLOR 'APEN' © V.`NYL VI GRTEx WOK COLOR 6REYST ' L Au_ i4AL LGOVERIN6 AND RUBBER BASE TO SE FURNISHED E INSTALLED ? f THE GON7RAGTOR THE CONTACTS FOR TtT i COVERING ARE AS FOLLOIIS SIGN TO BE CHANNEL BOX LET ERS INDIVIDUALLY MOUNTED TO HE STONE FASCIA. POWER TO BE THROUGH WALL_ AND WIRED TO TENANTS TIMER. . LIGHT SOURCE TO BE NEON. NOT USED SPECIFICATIONS AND DETAILS TO BE COORDINATED BY SIGN MANUFACTURER, MANUFACTURER, LANDLORD, AND TENANT. SIGNAGE TO BE SUPPLIED AND INSTAI 11=n BY SIGN CONTRACTOR. (N.I.G) COORDINATION OF ELECTRICAL PREPARATION BY GENERAL CONTRACTOR. VIGRTcX AKry KnrSeal YRODLY7PRODUCTS. -KIM oR ToB1N - c GGRA7IVE SERVICES - 641 LAKE 51KCC 1, SUITE 101, CHICAGO, LL. 60661 F14.600-55-2111 ! WOl-F 6l7RDON fROD'JG75 - SHANNON - IN7ERVV0`�ET! DESIGNS -.3 SOUTH NEWS ST. LOUIS, MO 63108 F1-6514-531-6200_ _ E NATIONAL W6413272. (TH IS NUMBER mar B` GIVEN TO RECEIVE NATIONAL f'RICKS.) O RUBBER 5AS SzOPPE', COLOR ?43 SLACK BROYfr Q VINYL MALLCOVERING, KORO EAL, "T AZZO', DOLOR 'CHARCOAL' Q VINYL NIALLCOVERIN , IKOLFG d', •415.1F.5272 RECEIVED CRT OF TUKWILA APR 1 7 1997 PERMIT CENTER SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 REFS JAMES A. LUCHTY ARCHITECT ARCHITECTVRE A4 1100 vaffi STEM SOBS seso KANSAS QTY, MO 84106 810- 818 -1805 FAX 848 -1878 O DETAIL @ COLUMN 1 1/L =1 CD DETAIL @ DROPPED HEADER 1 112' =1'-0" O T SAFE ANCHOR BOLT DETAIL 11/2".1 3 1; MTL_ STOPS • 16 5/B" GYP 137. xECTff4 SIDES SAFE UNIT - MR34151-ED BY THE CONSTRUCTION MANAGER ANC. INSTALLED BY T}E CONTRACTOR VN - 21P( s"'7CAGT LOCATION (4) 1/2" DIA HOLES IN BOTTOM OF SAFE UNIT TO BOLT TO INS FLOOR - VERIFY LAYOUT DRILL AND EPDXY (4) 3 /i;" ANCHOR BOLTS IN TO 11 FLOOR - 4' MIN. VEZIFY L. =46TH 1-41T1-1 SI!°FU t7cl [sLt 2/A5 NPI F-NLA4RrD PLAN 1/2' =1" -0" O : 2 AL ELEVATION 0 DETAIL @ LIGHT BOX 3 " =1' -0" PAINT 'SUDDEN abarr 53/O62 PAINT 'SLOVEN W c Y 95/O62 VINYL WAIIGGNERING, VORTEX, CK', DOLOR 'ASPE1" VINYL WALLLOVERINS, VTGRT: -X " GK ", COLOR 6REYSTONE' ALL WALLS TO B= PAINTED, SLOVEN' 5OYY b3/O41 RUBBER HASE, 'ROPPE', COLOR 3 "E.AGK ERONN' VINYL WALLCOVERItO, K.aROSEAL, COLOR "CA-ARGOAL' VINYL ALCOVERINS,'WOLFSO 1, • LAY-OL Ga30i5 0 !2-O" AFm 1 LAYEZ V2" GYP_ EP_ GOId'SL BcAD MP) 2 LAYS 1/2 GYP_ BD_ 11/2"=1 3 V2" MTL. STUDS 0 16' O- 518' GYP. BD. ON 3 1/2' MTh_ STUDS O lb" O_G. ¶O LIGHT FIXTURE 1 O SECTION @ GYP. 517. SOFFIT 1 V2' =1'-O" 1'-3" L ALL WALL C.OdER1NG S RJBI'3`R EASE FURNISHED 6 IP TAI 1 . BY GONiF.AGTOR_ SECTION @ GYP. BP. SOFFIT WALL FINICHES FINISH NOTES LAY -IN &EILINS AFF. 1 LAYER I/2" SYP. BD. J -MOLD 2 LAYERS i/2" 6YP. BD. J -MOLD 3 LAYERS I/2" GYP. BD. CORNER BEAD (TYP) 5/3" GYP. BD. ON 3 1/2 MTL. STUDS O lb" O.G. l it 1 1111 1 1 1 lln111F 1 1 4-0" 9 Q RECEIVED CTTY OFT MLA APR % 7 997 FEAMR CENTER 3 I/2" MIL. STUDS O lb" O. 5/3" SYP. ED. ON 3 I/2" MTL. STUDS O lb" O.C. 4,0 LIGHT FIXTURE SECTION @ GYP. BD. DROP 11/2"=1'-0" MONOPOINT LIGHT FIXTURE 1 ' -0" SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 REFS JAMES A. LICHTY ARCHITECT ARCHYTECTVRE A5 NSOO WAIN MOE, SONS MO KANSAS CITY. MO 84106 510 - 818-1802 FAX 048-1878 2"-O' X D-U' &1A5 LIGHT BOX _ A: 4' ',ono Ll Box US X OX 7 (� O 411 b' 2' 5'-IO V2' O DETAIL @ COLUMN 1 1/L =1 CD DETAIL @ DROPPED HEADER 1 112' =1'-0" O T SAFE ANCHOR BOLT DETAIL 11/2".1 3 1; MTL_ STOPS • 16 5/B" GYP 137. xECTff4 SIDES SAFE UNIT - MR34151-ED BY THE CONSTRUCTION MANAGER ANC. INSTALLED BY T}E CONTRACTOR VN - 21P( s"'7CAGT LOCATION (4) 1/2" DIA HOLES IN BOTTOM OF SAFE UNIT TO BOLT TO INS FLOOR - VERIFY LAYOUT DRILL AND EPDXY (4) 3 /i;" ANCHOR BOLTS IN TO 11 FLOOR - 4' MIN. VEZIFY L. =46TH 1-41T1-1 SI!°FU t7cl [sLt 2/A5 NPI F-NLA4RrD PLAN 1/2' =1" -0" O : 2 AL ELEVATION 0 DETAIL @ LIGHT BOX 3 " =1' -0" PAINT 'SUDDEN abarr 53/O62 PAINT 'SLOVEN W c Y 95/O62 VINYL WAIIGGNERING, VORTEX, CK', DOLOR 'ASPE1" VINYL WALLLOVERINS, VTGRT: -X " GK ", COLOR 6REYSTONE' ALL WALLS TO B= PAINTED, SLOVEN' 5OYY b3/O41 RUBBER HASE, 'ROPPE', COLOR 3 "E.AGK ERONN' VINYL WALLCOVERItO, K.aROSEAL, COLOR "CA-ARGOAL' VINYL ALCOVERINS,'WOLFSO 1, • LAY-OL Ga30i5 0 !2-O" AFm 1 LAYEZ V2" GYP_ EP_ GOId'SL BcAD MP) 2 LAYS 1/2 GYP_ BD_ 11/2"=1 3 V2" MTL. STUDS 0 16' O- 518' GYP. BD. ON 3 1/2' MTh_ STUDS O lb" O_G. ¶O LIGHT FIXTURE 1 O SECTION @ GYP. 517. SOFFIT 1 V2' =1'-O" 1'-3" L ALL WALL C.OdER1NG S RJBI'3`R EASE FURNISHED 6 IP TAI 1 . BY GONiF.AGTOR_ SECTION @ GYP. BP. SOFFIT WALL FINICHES FINISH NOTES LAY -IN &EILINS AFF. 1 LAYER I/2" SYP. BD. J -MOLD 2 LAYERS i/2" 6YP. BD. J -MOLD 3 LAYERS I/2" GYP. BD. CORNER BEAD (TYP) 5/3" GYP. BD. ON 3 1/2 MTL. STUDS O lb" O.G. l it 1 1111 1 1 1 lln111F 1 1 4-0" 9 Q RECEIVED CTTY OFT MLA APR % 7 997 FEAMR CENTER 3 I/2" MIL. STUDS O lb" O. 5/3" SYP. ED. ON 3 I/2" MTL. STUDS O lb" O.C. 4,0 LIGHT FIXTURE SECTION @ GYP. BD. DROP 11/2"=1'-0" MONOPOINT LIGHT FIXTURE 1 ' -0" SPRINT PCS PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 —WA 11 APRIL, 1997 REFS JAMES A. LICHTY ARCHITECT ARCHYTECTVRE A5 NSOO WAIN MOE, SONS MO KANSAS CITY. MO 84106 510 - 818-1802 FAX 048-1878 -GiF1GAT IONS 1.0 GENER RECIUIREMMTS 11 All seek shalt be done in oceaderce with this highest quality statda!'as of the hrLetry for reaatoriO9 acesemeseitio installation of each trade. 1.2 Any diserepareas in drawings or specifications stall be breught tG sr.:. lion Of the Arcot and Gars'*sac"Lion Menager clarified, prior 0040 shalt ossornet the :test expeesive *retied er maeria, 13 The suisortimators shall provide the the GCnstructice Manager with scheadifi g information prior to Micro, which wail be updated t Chore ore any Changes. 14 Ali construction and materials than corcphj wits cony and ail applicable codes. rules and lass. 13 9./bmrait for cioprovai, prior to fek rivation or purchase, shop dnrosirras and/or samples for Items as requested by the Architect or Owner Represertattve. 1.6 Unless noted, Faro materials aid Brander daall remain_ Any damage disc to these Items shall be repaired to the original condition by a means approved by Cie on moor. 15 6UILDIN6 ACCESS: Access to the spats shall be coordraorted with the building Darer. G.141110 Gf G... , ..,., will be confined to the costructbn area any. b. Any construction worker caught stealing, drinking alcohol. or using erg Illegal substance we31 be inn xticliately bared from the adding. A professional manner end i areas opriate laagaa9e or comments will rot be tolerated G. No cookk g of erg kind will be allowed on the site- d_ Absolutely roe food, bays-cases c smokng will be allowed on the construction site after parting or installation of carpet has began_ IB MI cortrnmicatoa required °hail be through the Gore#e uctbn Jack Vaughn, Perry Keesier Construction (4I3) 782 - 4646 Fad (413)182 lei Provide senora ba! of dl finish mrateriais not provided by constructicra inanaser for approval prior to purchase orders_ I.10 Ail work seal! be in st: lct aca-dancc with all governmental codes. Leafs or regulations. Alf mw }ra tai shall meet flame and smoke requirements of the prevailing local Buildrg Code, as noted in the Construction Drawings end Spastic tiers_ 1.11 Tic contractor shall remedy any detects in the work and pas for amA Manage or other work resuittig therefrom which shall pear wit hn a period of one (1) year from the date of final acceptance unless a longer period is othenese specified or a different warranty period has been estatlished in the substantial correlation certification_ 1.12 All cutting, coring, drilling and patching required for the installation of systems herein described, shall be provided by the Contractor. Structural members shall not be disturbed wthea prior approval of the Archltect/Owner_ All areas disterbed by work performed under this contract stall be neatly repaired and refinished to the condition of adjoining surfaces n a suitable manner to to Architect/Owner_ a. Where cutting or coring is necessary, it shall be done by methods wwilich will not damage the structure, and shall be subject to prior written approval of the Architect. Any damage to structure or finished surfaces shall be repaired to the satisfaction of the Construction Maraager at the expense of the contractor. The contractor shall pay all cost assalated with obtonng approval of cutting or core drilling of existing structure from a registered engineer. b. The building owner is responsible for removal and capping of urvsed or abandoned conduit, cables, duct work, plumbing or other materials to the point of origin, withn the caafines of the tenant space prior to commencement. Contractor is notify the Construction Manager of any discrepancies before proceeding. t267OE 3L 'hie drx?w stews seeve _- w oriciv drawings for to amend leassit Oi the various errs of eaelpremats li waver, Scat of easement, excessortes -sp*cnalties embalms f e). mad tenant systerre ore acgrearamoitia amid e junction box, pulha®x, or other simnTlcr tams are respired to complete an tns'tabebcn, the contractor shall notifaj the tustrvctBon Menoger of the add'tircmal week and cost prior to proceeding_ 1.14 Ail scale dimensians are opproxixte_ Before prong with any work, the ca tractor actor shall coreAuil check and worths ail dimenelors- Any discrepancies ore to be broucht to the attention of the Gonstmetion Manager. 1.15 Stbsttutiors will only be considered prior to receipt of bids unless petters nosiest for acGeptcrce has been received by the frchtect and Owner Representative at least 4e hairs prior to the date for receipt of bids_ Each recpeet shall include the rams of the material or equbmert for ifaich b to be su7 stlbuted and a complete description of the proposed substitute including eimeings, tats, performance and test data, and any other information necessary for can evaluation_ A statement setting forth at G other or t Incorporation of atio lee substitute would require shall be included_ The Architects and Owner's Representative decision of acceptance or disapproval of a proposed substitution shell be firnai. if the Architect and Oraaerrs Repssentathre Zubstlb,tions rior p to any of bids. such acceptance will be set forth in 017 Addendum. Bidders shall not rely upon ac.aeptance mode in Dray oilier manner_ No substitutions will be coresidered after tae Contract Award unless specifically provided in the C.onb Documents_ 116 The review of shop drawings does not relieve the contractor from resporstelty for errors, omissions or deviations from the centrract documents, unless in writing they are coiled out at the time of submission cad our cten acGepta ee_ The cabala b responsible for details, size of members or qua*eties; or omissions of components of fittings; or for coordinating terns with actual building conditions and adjacent wok. and °misstate discovered of a latter time met be fixed by the contractor with no cost to the owner_ in All shop drawings prepared by the manufacturer mist be pre checked by the contractor_ The contractors stamp of approval ad date rust be enckided with a specificat..ton pareg n which submitted Grad the project noes_ Suienittds not containers; the above information will be returned with out action. 135 The contractor shall maintain on site up-to -date complete `Record° set of prints which are corrs ted deity with all changes In layout from the original dr q o^ a. - + .c specificestans, tireksing MEP_ Contractor shall deliver "Record' set to Construction Manager prior to final payment. 1.14 Contractor is responsbble for obtaining ALL permits and inspections and paying all fees therefor_ Gontrator shall provide Owner a copy of the buildng permit prior to commencing any work_ Contractor will notify the Costruction Meager of all permit and code inspections. All punch be will be scheduled with the Construction Manager by the contractor. 120 Gontrator is responsible for coordinating all trades even If the traded under a separate contract_ Contractor shall sibmt a list of each subcontrectore' nave, contact, address and telephone number to Construction Manager prior to beginning destruction_ 1.21 Contractor shall verify all existing conditions and work in place iOUout all new walls and partitions; verify dimensions, locate existing utilities and mechanical systems to be modified, and notify the Construction Manager of any disuse/m1es prior to fbegimng demolition and/or construction_ L - Owner reserve the r to substeute material ors duo to avaI Ill j caod/or receipt of faAty materials, The substituted mnaterk 1 must be equal acrd Gppearoma_ (lire Intent b to Clow for example, Convect ceiling tile n lieu of Armstrong, er Beanja'nn Moore in lieu of Pratt s Lambert, etc- r no way shaii the substitutions effect the intent of the building code far which to building permit was issued The Contractor shalt saran j sibstitution for approval prior to order_ 123 Gontnxtor shall make very effort to keep the building areas diem drag safe durig the a rstruetior+ period Contractor shall use walk -oft mats to protect hoarier Contractor and re hers shall prover* noise, dust, smoke, and odors from interfering with the normal operations of the ..ro'pei oe center_ a_ Construction debris will be removed from the site per the shopping cater guidelines. The site area shall be kept Glean and organized at all tins_ b_ Before cog demolition and/or construction work teas begin, the Contractor nest det'ernair e w et cx such work will affect the BuIldrrjs fire alarm distort If it b determined that such demolition ardor construction work may trigger the fire edam system, /14111 be necessary for the Contractor to nil's the dapping center office so the system can be removed and restored to service upon completion of the actvtb(- G_ Contractor Hill place smoke detector dust bags on the detectors in the areas where production of dust well occur_ The dust bags must be removed by the end of each working day. Contractors sill notify the shopping center office before placing and removing dust bags to prevent false alams_ d Ail wall, floor or ceiling penetrations shall be sleeved and adequately sealed to prevent the spread of smoke card fine per applicable codes. The Contractor shall provide temporary protection stien Rork ccrnot be completed in ors work shift. e_ The Caeca** shaii provide an adequate number of fire extegubhers' in t he work area throughout the construction period f_ The Contractor shxafi nobly the Landlord ndlord 24 }wars prior to raj electrical stet which rn j effect existing ' tenants. g._ The .Oortractor is responsible for shutting off all lights in the 'construction area upon completion of the day's activities_ L24 The shopping center office is to be c ntected before the start of such work ce pointing, staining, or finishing that might create unwelcome odor or noise in the building. 125 Clean-up a_ The project site shall be swept up and trash ready for removal on a daily basis_ Care shall be taken to keep ad jacent occupied tenant areas clean during construction on a daily bas's where work required by this project dieturbs adjacent areas. b. The contractor Is res s1ble fa removal of construction debris_ Locating of large rosters for contractors use must be approved and placed as directed by the shopping center coordinator_ The Contractor will obtain then own permit for the durtpster. Prior to occupancy, space shell be . left clean of all debris, wails and other surfaces wiped down, glass washed, blinds dusted, floors swept and/or vacuumed, tile cleaned and woodwork cleaned. d. Contractor is responsible for delivering the Premises at completion in a 'move-in' condition. 126 All penetrations through the building Fire Rated Malls and Fire walls will be sleeved and fire caulked- Refer to Section 82. 2D GARP1 RFIRer etePSUM BOA SI7 2i Provide 3-51/1, S sauce metal studs dt t6' or Grams noted otherwise) rd h nammr frocks and necessary accessories as recommentied b9 Us moneociapree far a Refer to Mss for wail types, otter stud sib, and flashes_ shall 22 Hans caretruction foe Inspected be installation of was shrill be smooth acrd projea r+a rrperfectiars, they driab sx plumb and stroicjit and show no bulge or envhots at jogs. All seeding snarl be done with' a metal screen. 23 Egan 3ocrd to be 5/8' Tigre: 'X %peen board as provided by egos= prod t 4L U all pawl joints, sex* call expos of gtrasum board to be cowered by a stock extol edge Erin similar to .401 metal b-Wr by U.5 G psur> All interior corners shall be taped dl meaner corners shall be covered wsth a rh corner bead with tape_ 24 Door Frcarest To be aped to e dstiny base haAktrg hollow meta door francs (fire rated as rcquced en (4 � ASA s jambs trike_ Rem for schedule for dirmaislons aid Weakens 25 All frames old asseables to conform to applicable codes. and iz p properly labeled as required by the code_ 26 All doors shall be urderacrt as reached by differ-ere flooring card arcs derscrd d in chmadice �-4 arcs fe a schedule. 27 If sound attenuation bleicets are shown an the construction c raaln9s they shall be USG or other approved emeerd or gloss Hoer Menke*. 1911 wall cavity with 2" of h PCP derrr star fiber sound batty Comply pith mcnafactunear kstructions for particular cons or (retaliation in each case_ Place sound otterudion blankets n stud caves of sound rated partitions_ r riafibn ft searety between studs_ Haft aids of blaster closely together and fill a I volcb. 23 Use wMer res ant ' . bored adjacent to all plarbi19 fixturee as rated in the construction doom nts (ricks, urinals, potter Closets, jantar clock)_ 2_4 Hollow Metal Moor Frames shall X as noted eh the construction documents_ 16- gauge thank -dowel tape, mitered comers shall be rcmeorced whin integral tabs for scare tterbcking of yeti: to head Strike jamb to have 3 rubber mutes, factors iretailed. UL rated ce scheduled. 210 Doors and Scenes stall br pre - machined for hardware_ 211 Caulking shall be erab to P ecora acnjlic latex caulk 212 W noted on the construction documents provide sound emubtbn caulking co top and bottom of all de ten g walls. Caulking shall be equal to Peters .3A-i8, noon -drying ba> I rubber_ 3D MILLWORK /CABItETRY (there ndicated on drawings) All millwork to be faked and installed b the Canstrucban Manager_ 31 All work shall be to tar highrht industry stehdcrds with its higfaest quaiitrj materials_ AU wank shall be plumb, level, true and reigned it shall be free from defects and warranted for I 32 Provide and install all blocking for proper installation of all ca-pent raj cold millwork. 40 DOORS/HARDWARE, eL ASSIG AZINS 4_I Provide hardware as indicated in the door schedule. All hackwork to be cantrted through Owners selected 'osreth and coincide with building 42 ire schedule. (Refer to Door Saleable for additional lnforn about hardware, special keying Grad locking cement_ if Pairs of doors are indicated, provide pars of hardware with automatic flush bone-equal to Ives sr7.57 (except on closets, which can receive standard fish bolts equal to Ives *262) ?rovidc hardware from the following mastacturer - Precision itullt leutts (PBB) Locks/Latches - PD.Q_ Closers - Dormer Steps/'Silences - Sirgnai /re Brass flARONARE GROUP #A (3) A. PE381 45" X 45' 626 Hinge (1) EA. 5P126PHL X 2 3/4' X ASA 626 Prssage Set (Provide privacy set for al in lieu of passage set). 00 EA_ 53e1502PT 630 Nlollstop 0) EA. 551337 -A silencer HARti elAi GROUP (4) A 145' X 45' 626 Hinge (1) E!L SP126PfL X 2 5/_4" X ASA 626 Po sage Set (1) EA. Push Button Lock - Smpiex LIOII. 0) A. Dutch Door Holt - Ives *054. 0) EA Z8A802PT 630 1'lallstop (4) EA. 581337 -A Silencer ?'.ARD1°lARE.GROUP Z*0 (3) EA. 3*1 45' X 45' 626 litre (I) EA SP126P#1L X 2 3/4 X ASA 626 Passage Set 0) EA. 7601. X PA X SNI Alum_ Closer (I) EA. 534 502FT 650 Niol'stop (5) EA 531537 -A silencer HARDWARE GROUP *2 (3) E,4 BSI 43' X 48' 626 Hinge (1) *A. asi241.1L X 2 3/4' X A5A 626 Passage set (1) EA_ Pish'3utton Lock - Smplex L1011. (1,) E 7601 X PA X *NI Alum. Closer (e) EA- * 02FT 630 Wallstop (3) EA 53357 -A silencer 43 ADDITIONAL REQUIREMENTS FOR RATED DOORS: Closures to be provided era all fire -rated doors_ Proviab Closer (equal to LGN regular arm 4030, Hro¢e), door sweep and all rcq iced gaskets. Provide Lever Lockset to match hardware specification_ 4.4 floor Stops. When a wall stop is not possible, provide floor stop equal to Ives #438. 43 Ylherc noted subcontractor shall furnish all boor end materials necessary to complete glass and glazing indicated. Ali glass shall conform to all applicable codes and ordinances. 4.6 studard Tenant Interior Doors: solid Gore Wood Veneer Doors shall be equal to Weyer DSP -20, Banded Particleboard Core filled, 3-oYa x -1'-O'h (unless noted)_ Face assembly shall be attached with Type 11, water resistant adhesive, for interior doors. Provide 5 ?° lock block for loci_set./latdiset hardware. Standards: Adel, Tube FG and NVIMA-IFel, IS -I-18 series. Finish veneer shall be ready for primer aid pant. Doors shall be 1-314' thick with solid wood edges . UL rated as scheduled. Verify all sizes prior to ordering. 4,5 All doors and assemblies to conform to applicable codes and shall bear the appropriate labeling as called out on tee _let_ 44 The contractor is to provide the architect, construction manager and tenant 3 copies each of the hardware and keying schedules for review prior to i stallation- 5.0 FINISHES 5.1 All finishes, materials c'nd colors ore called out in the finish schedule. If not noted, contort Architect or General Contractor WALLS. 5.2 Any finishes shall meet the requirements of the code for Fire Safety. Treat If necessary to obtain correct ratings_ 53 Seal tops and bottoms of all doors. 5.4 All paint on a gypwm board surface shall be two coats; one prime and one finish. The surface shall be painted with PPG eggshell latex or semi -gloss enamel when indicated on schedule, or equal as approved by owner. 55 Paint on surfaces other than gypsum board shall be as follows: a. Painted wood - one coat each interior trim primer. Vitralite enamel undercoating, Vitralite enamel 5.6 All walls to receive vinyl or fabric waltcoverIng shall be sized before installing the wallcovering. Apply vinyl or fabric as recommended by the manufacturer of the material using approved adhesives and techniques. Material, when of the same selection in a room, shall be from the same run. Variations in color or texture are unacceptable. All seams shall be straight and vertical cut with a straight edge. Seam busters shall be used for all seams. No piece shall be less than 12" wide. FLOORING 5.7 Rubber base shall be per the finish schedule that will list manufacturer, color and type. Contractor shall provide and install product in 12' lengths to minimize Joints and use corner pieces. 5b Carpet shall be per the finish schedule on the drawings, provided and installed by contractor. The installation shall be warranted buckle free for one year. Glue down carpet shall use a strippable carpet adhesive. Carpet shall be installed in strict accordance with manufacturer's requirements and by trained personnel. Carpet which is bordered by another floor material shall be transitioned with a vinyl or rubber reducer or trim piece, unless noted on the construction documents. Color samples to be confirmed by architect. 5.9 Vinyl composition the shall be per the finish schedule on the drawings, provided and installed by the contractor. Tiles shall be 12 "xl2 "xl /8" and shall be installed' per manufacturers recommendation with manufacturer approved adhesive. Contractor Is to confirm levelness of subfloor before new floor material Is installed. Edges Joining other floor coverings shall have vinyl or rubber edging strips or reducers to have finish with least visual impact. Strip and wax tile upon substantial completion of project. 5.10 Solid vinyl tile shall be per the finish schedule on the drawings, provided and installed by the contractor. The tiles shall be 6 "x35:4 "x..120" thick. and shall be Installed per manufacturers recommendation with manufacturer approved adhesive. Contractor to confirm levelness of subfloor before new floor material is installed. Edges joining other floor coverings shall have vinyl or rubber edging strips or reducers to have finish with least visual impact. 5.11 Porcelain tile shall be per the finish schedule on the °swings, provided and installed by the contractor. Tiles shall be 12 "x12 "x5/16" and shall be installed per the manufacturer's recommendations using a setting material' of latex portland cement mortar (per ANSI A115.4) and grout (per ANSI Al le.6). Contractor to confirm leveling of subfloor before new flooring Is installed. Edges Joining other flooring materials will have a stainless steel angle set to protect the tile from chipping and cracking. Clean and seal the upon substantial completion of project. CEILINGS 5.12 Ceilings shall be per the finish schedule. 5.12 Gypsum board ceilings shall have direct susperston system equal to USG. Gypsum board thickness shall be 5 /ei", unless noted. All joints shall be taped, speckled, and finished per USG specifications. 5.14 Install acoustical lay -in ceilings in accordance with manufacturer's directions and drawings_ Ceiling tiles to be 2'x4'x 5/8" Mineboard, non- directonal fissured as manufactured by Armstrong or Celotex. Color per the notes on the reflected ceiling plan. 5.15 Suspension system shoe' be an intermediate duty 2'x4' grid system as manufactured by Chicago Metallic, Donn, or Armstrong. Color to be white unless noted otherwise on the reflected ceiling plan. Install in accordance with the manufacturer's recommendations and ASTM 0636. 6.0 FIRE / LIFE SA 5.1 Furnish and Install fire extinguishers as required by code. 62 Firestop. a. The contractor is to provide fire stopping at any plumbing or electrical conduit penetration of a two hour wall assembly equal to "METACAULK 950 FIRESTOPPING PENETRATION SEALANT ", applied in accordance with UL System Number 442 and ASTM E -814. b. The contractor is to provide fare stepping at any plumbing or electrical conduit penetration of a two hour floor assembly equal to "METAGAULK 950 -10 FIRE PENETRATION SEALANT ", applied in accordance with UL System Number 273 and ASTM 5 -814. c. All penetrations through the building floors, Gore walls and Fire walls will be sleeved and fire caulked. b.* Fire Sprinkler a. The sprinkler contractor shall be responsible for stamped engineered drawings as required by the Gtty that includes a drawing of the existing layout (reproducible avelleble from the Owner) including modifications required by the reconfiguration. 7.0 MISCELLANEOUS 7.1 If any roof penetrations are required for this project, the Contractor is to coordinate Installation with adjacent work such as roofing, sheet metal and other work to ensure creation of a complete weatherproof assembly. Anchor work securely to supporting structure, but allow for differential and thermal movement. BREAKROOM EQUIPMENT 1.2 Contractor shall provide and Install all new breakroom equipment as noted on drawings and specified below. Contractor shall provide a complete installation, to include all plumbing, piping, openings, sleeves, etc. (see engineering specifications and drawings): a. Construction Manager to provide and Install one refrigerator (white In color). b. Construction Manager provide and Install one Microwave. Contractor is to Install electrical outlet behind microwave opening as noted on the electrical drawings. c. Coffee Maker is not in contract. d. Construction Manager wli: provide sink (sink comes pre- Installed In casework). Contractor Is to supply all associated screws, fasteners, piping, etc. to provide a complete installation Including hot and cold water with sink shutoff valves. RECEIVED C1 Y OF TUKWIIA APR 1 7 1997 SPRINT PCS PERMIT CENTER PARKWAY PLAZA 17540 SOUTHCENTER PKWY TUKWILA, WA 96019 098 -WA 11 APRIL, 1997 REES 4AMES A. LICHTY ARCHITECT AFICHITECTL7RE J IMO YAW Mee, eons X60 UNE. Cram, YO 64106 1116- 618 -1298 Ye 648 -1676