Loading...
HomeMy WebLinkAboutPermit D97-0160 - JUSTICE RESIDENCE - ADDITION AND REMODELCity of Tukwila Parcel No: 734660 -0050 Address: 2945 S 135 ST Suite No: Location: Category: ASFR Type: DEVPERM Zoning: LDR Const Type: V -N Gas /Elec.: Units: 001 Setbacks: North: Water: 125 Wetlands: Contractor License No: Print Name: ) ‘) i DEVELOPMENT PERMIT Signature:___ ~`� �v '� ` 4._s Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: Status: Issued: Expires: Occupancy: DWELLING UBC: 1994 Fire Protection: .0 South: .0 East: .0 West: .0 Sewer: RAINIER VI Slopes N Streams: OCCUPANT JUSTICE JOYCE 2945 S 135 ST, TUKWILA, WA OWNER JUSTICE JOYCE Phone: 2945 S 135TH SEATTLE WA' 98168 CONTACT AL JOHNSTON P.O. BOX 1899, YELM, WA 98597 k********************************* A******************* * * * * * * * * * * * **'k******* * **** **** Permit Description: ADDITION TO EXISTING SINGLE - FAMILY RESIDENCE 305 SQ FT AND REMODEL OF EXISTING LIVING SPACE.. k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * *k * * ** Construction Valuation: $ 31,633:65 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. JJS Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No Size(in) .00 Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape. Irrigation: N Moving Oversized Load: N Start Time: End'' Time: ,. Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public Storm Drainage: N ' Street Use: N Water Main Extension: N Private Public: k**************************** * * * * * * * * * * * * * ** * ** * * * * * * * * * * * ** *fit * * * * ** * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ ' ' 685.54 k***************************•**************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * *•k (206)241 -8678 Phone: 360 458 -4600 Permit Center Authorized Signature'! Q `Matta_ Date: 1 I hereby certify that I read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am_authorized to sign for and obtain this development permit Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. End ..Time:. Fill: 097 -0160 ISSUED 06/20/1997 12/17/1997 b r Li :. awl (206) 431-3670 D97,- 01 Address.2945 '''S u i te Tenant Status: ISSUED Type DEVPERM App 1 i ed .05/12/1997 Parcel # 734660-0050 Issued: 06/20/1997 k* ** * ** *k' **k** *k* **** k*******' kk k**** k******* * * ** * * *•k *k * *k * *-k *k Permit Condition Temporary-:' .control .me.asur >es:, be 'i`mplemented as the first `or der: of,busines to pr event sedimentation off te or into existin s torm dr`alna'ae' ;fao.i 1 it i'ec - .strong r�eoorrimer: ed"that storin' cii^a'ir�agc designs 06 certi by a .1 1 ceKsed engineer; ot rw r se �`the own assumes l i a b i l i t y 'for tth:e des i gn arid. any :Subs ebtEen:t re la te damages • ? M ;;' 3 , 4 No:': changes W i r l l.' be,ratle to the plans unless "approve Tukwila Bui:idiri:g D.r,vision.; ' Electric l " : p r mits r sh l.tl be obt - , i ned through '.the Wa;shingtori State L?1,vi Labor and ,Indus;tr�ies and alj electri work X 11 Jae i nspected by :. that agency (24'8- 6630) A l l t pe r r mits inspection ',.r�ecor ds. and approved .plans shal l` b' available a:t, the lob s;i a pr ", ax. the start of any ,.con strcr'.+c.irn'` These documents ; are :.toLbe. ma intained •and ava`i a bilekiun til final inspection ap.p.rova.lr • i granted All, r constriction to :be dune; In conformance with approve, p"1 a}ns, and requi rements .of:' r the ' .Un,i f,or m Bu,i I d i ng Code Ed' tion) as amended. ", uniform Meci ar�l Cede (1994 Edition ) and 1,Washington 4,3,tate Energy Code ;+(1994 Ed) ti on) All wood :ta remain in fpl , concrete : s hall be treated `wood Any e xposed in sula on tis` ba,c1;in'g material shall have a Flame • Ser d. •Rat ing''",of 25 or less, and matPria'1 shal all bear~ ldent. 1'1 cat�ion showing the fire.. performance rating thereof Valid qty jat PeT mi. The is suance of a°' permit , ,. app • pianY�, specificati and comput sha1:1 ,snot "'be3 - cor1- s.tru `d to'Ybe a permi for or ari appro`v l of 'any v i of atl o af: any' of the provisions: of .the rbu1`lding•"code =.or of any othe nance of the jurisdiction . presuming gi ve auth'orltv-; >t,o;° vio:la or .cancel .the. :code shall i,be Val 4d d Project Name/Tenant: \J (-� I (, 2 \ j C-' �y l4CY)O Construc n: a �' i',eft1ocl i Is this site served by: fa Sewer ❑ Septic (King County Health Dept. approval required - 296 -4722) Site Address c 4 5 , t ..s ___-!--( 1. ,i..., rj te /Zip: rjl Tf IFrcQl ev b, � Proposed New Square Footage: QS sq. ft. Dwelling sq. ft. Covered Deck(s) Property Owner: "' sq. ft. Garage /Carport sq. ft. Accessory Structure(s) Phone: Floor Area Ratio: (total floor area of all structures divided by the area of the lot) .7- Yu) Street Addres : "' c1, S S 13 S •57 Citty State/Zip: c' ,f- t a Fax #: Contractor: Phone: Street Address: City State /Zip: Fax #: .architect; P '' °1 - .Sf- �� , D 37 o 1 Phone: 3 Ca 0-153- ' c'v Se IAddre 09 u State/Zip: Fax #: En ineer: g Pho Phone: n. Street Address: City State /Zip: Fax #: Contact Person: iv � 4 N 60 Ph ,90 ,... q ) Street sb •c \, co Lity jotatg2ig.: _ \ c #: 30° 4$1 , .5e Description of work to be done: kaa l k b() to -E„CI fib f\ 5 � (1( Il = rY \t i.e 43i cienC-e 3o S (A. ft . Gr\ d r..e rYl oc+-el , J Type of work: ❑ New Single - Family Residence Interior Remodel- Single- Family Residence Remodel /Addition to Accessory Structure Decks) - Covered & Uncovered Addition - Single - Family Residence Residential Accessory Structure* El Garage(s) ❑Residential Reroof Is this site served by: fa Sewer ❑ Septic (King County Health Dept. approval required - 296 -4722) Existing Square Footage for Structure: / D' sq. ft. Dwelling sq. ft. Covered Deck(s) sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck Proposed New Square Footage: QS sq. ft. Dwelling sq. ft. Covered Deck(s) ft. Uncovered Deck "' sq. ft. Garage /Carport sq. ft. Accessory Structure(s) �sq. Floor Area Ratio: (total floor area of all structures divided by the area of the lot) .7- Yu) For a4:1- Asseasery- dwelling, provide the following: `6') O Lot area Floor area of principal dwelling Floor area of accessory dwelling ' Provide documentation that shows the principal owner lives in one of the dwellings as his or her primary residence. Single - Family Residential Permit Application CITY OF TUV'NILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile* ) ( 3 US n R STAFF USE ONLY Project Number:- �. Permit Number: 0 APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews shall be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Hauling ❑ Land Altering: 0 Cut cubic yds. 0 Fill cubic yds. ❑ Moving an Oversized Load: Start Time: End Time: ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be re- viewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall ex- pire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: 1 Application t ken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM SFPERMI7'.DOC 2/13/97 BUILDINGOW .R UT UT 0141Z � AGENT: Signature: • 400 Date: / Print name. 7f C 0-/072) N ! "/o e --7J� F 71:51....34:. Address: `n v` A / / ( 1 9 " < „ 7 City /State /Zip: ye ` t ( w 7 ALL SINGLE- FAMILY RESIDENTI! PERMIT APPLICATIONS MUST BE BMITTED WITH THE FOLLOWING: • DRAWINGS PREPARED BYs.. REGISTERED ARCHITECT OR PRO..:SSIONAL ENGINEER MAY BE REQUIRED BY THE BUILDING OFFICIAL > ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Copy of recorded Legal Description from King County 0 ❑ Certificate of water /fire flow availability (Form H -11 a). Contact the Public Works Department (206) 433 -0179 for servicing district. ❑ Certificate of sewer availability (Form H -11). Contact a Public Works Department (206) 433- 0179 for servicing district. © I 3 S( ❑ Metro: Residential Sewer Certification (if Tukwila Sewer District) (Form H -12) n l King County Health Department approval for septic - 296 -4722 Four (4) sets of working drawings, which include: ❑ 5& Site Plan (see example Form H -16) 1. Existing fire hydrant location(s). Proposed access road. " t Driveway location- driveway shall be 10' wide minimum and 20' wide maximum. If driveway is over 150' long, driveway shall be 20' wide and have an approved turnaround (City Ordinance 1741). North arrow and scale. Building setback from property lines. Any proposed or existing easements must be shown on plan. 6. Public Works review requires the following on site plan: driveway location (10' min., 20' max. width), show proposed and existing power, water and sewer lines, existing storm drainage system, downspouts and foundation drains, and where drains tie -in. 7. Parking plan. X Lowest building elevation (if in Flood Control Zone). Estimated /proposed topography at 2' intervals and proposed elevation of lowest floor level. 16. Identify location of sensitive areas slopes 20% or greater, wetlands, watercourses and their buffers. 1,1:'Identify location and size of significant trees that are located in sensitive areas and buffers or the shoreline zone. Of those, identify which are to be removed (Title 18, City of Tukwila Zoning Code). T. Identify location of high water mark of the Green /Duwamish River if site is located within 200' of the high water mark. 13. See Public Works Checklist for detailed site plan information required for Public Works Review (Form H -9). ❑ © Foundation plan and details ❑ 91 Floor plan ❑ ffi Roof plan ❑ 71 Building elevations (all views) ❑ Building height ❑, a. Building cross - section ❑ M Structural framing plans and details necessary to completely describe construction ❑ ❑ Washington State Energy Code Data (Gas /Electric /Oil /Propane /Heat Pump) Form H -15 available at Permit Center. OR Prescriptive Heating System Sizing Chap 9 Form H -6. ❑ ❑ Complete Land Use Applications if not previously submitted (i.e., Reasonable Use Exception, Variance, Shoreline or Tree Permit). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance and other land use or SEPA decisions. ❑ ❑ If dwelling has a septic tank, and a bedroom or bathroom are added, provide written approval from the King County Health Department or the Tukwila Public Works Department prior to submittal of permit application. ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE ATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. SFPERMIT.DOC 2/13/97 REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F Coari. CoP/ PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER bcrl • OUoO DATE 4-3- 97 PROJECT NAME DEPARTMENT: BU ING DIVISION El FIRE PREVENTION [J PLANNING DIVISION PUBLIC WORKS 5 rC;TURAL [J PERMIT COORDILUOR DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE (.9 q -j COMPLETE NOT COMPLETE E NOT APPLICABLE 0 COMMENTS TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF I I (If routed by staff, make copy to master file & enter Sierra.) DATE 1 1 DATE DUE DATE b' et- q 7 APPROVALS OR CORRECTIONS: (ten days) APPROVED APPROVED W/ CONDITIONS NOT APPROVED (attach comments) Q CORRECTION DETERMINATION: DUE DATE APPROVED I I APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 DATE (Certification of occupancy required. 1 REVIEWERS INITIAL REVIEWERS INITIAL c Ptnnii. C�or&u*ov CoP PLAN REVIEW / ROUTING SL ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION PUBLIC WORKS D97 -0160 JUSTICE JOYCE DETERMINATION OF COMPLETENESS: (T,Th COMPLETE El NOT COMPLETE NOT APPLICABLE 0 COMMENTS n r none a pp i f Mali-' 5O Or/ )q TUES /THURS ROUTING: PLEASE ROUTE El NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED WI CONDITIONS fl NOT APPROVED (attach comments) 0 CORRECTION DETERMINATION: APPROVED Ej REVIEWERS INITIAL C:ROUTE -F DATE DATE DATE DATE 5/12/97 FIRE PREVENTION iJ PLANNING DIVISION ❑ STRUCTURAL El PERMIT COORDINATOR 11 DUE DATE 5/13/97 DUE DATE 5/27/97 DUE DATE APPROVED W/ CONDITIONS El NOT APPROVED (attach comments) 0 (Certification of occurancy required. ) ik.h*k * Lek** ** **k**k�% *** *.k* *k* * k**** �A* klkkk h *k**kkklak #•.kk**•k c; aF TU KW LA`, wk ' �.0). C, TRANSMIT **k*k * *k. * *k *: *.kkk * * *k:•�1 k* lc kir, *hk* k * * * *41 **k#kh.k. k * *k%*kk:% TRANSMIT. number ^: R9740602 Amount 417.25 06/20/97 08:52 Payment Method: CHECK Notauion: JOYCE JUSTICE .', - Init: SLB Permit No D97 -0160 Type: DEVPERM DEVELOPMENT PERMIT Parcel No 734660 -•0050 Site Address: . S 133 ST. Total Fees: 683.54 This Payment 417.25 Total ALL Pmts: 685.54 Balance: .00 ** ASVk***** A***/. elf* Ak* i**• A4k*i* * * ** * ** *A** *hA4 *A *s1***i *A *hi A+t•k4,4 Account Code Description Amount 000/322.100 BUILDING - RES 412.75 000/3 STATE BUILDING SURCHARGE 4.50 i' X21 06/20 9719 TOTAL. 417.25 '• • *licirititic*.ir'***1■41.1(*4 4.1%*********A********41**** CXTV OF 'TOVNILI4 'WA -C)1Cat TRANSMIT TRANSMIT Number: R,9700580 Amount:: 268.29 05/12/97 1336 Payment Method: CHECK Notation: JOYCE JUSTICE Init: SLB Permit No: D97-0160 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 734660-0050 Site Address: 2945 S 135 $T Total Fees: 685.54 lhis Payment 268.29 Total ALL Pmts: 268.29 Balance: 417.23 •Account Code Description Amount 000/345.830 PLAN CHECK - RES 268.29 • 0410 05/12 9705 TOTAL 268.29 COMMENTS: Type of inspection: `11 i3 C-1 I �V � g ,q- ._...s . -6Auc- ,A,--11,,f--1.z13 AA 1.3-1aG /.t,. kNGN t>J co►ar -ar .,,4 -ro TAN c . ' ,,' 11 s% O �E y Nun Sv -c(L i s Ape tW V V Tio - e~■•I c,6` S : 1'- y" T Z' 01.1 'ni$s SIDE dF T Date wanted: , ■JO YYtA-5u>° v013310 + Of — 06 - P L P-w S col I S NA . Phone No.: Project: - ` V ,� C� \.J Type of inspection: `11 i3 C-1 I �V � Address:Z S , f called: c, ' ,,' 11 A1 4:.F. Special. instructions: Date wanted: , Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. INSPECTION RECO Retain a copy with pe it y0 . 0)t0 0 PERMIT NO. • (206): 431 -3670 Corrections required prior to approval. Inspector: Date: l " F $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: )c.K; -e. -.,y 02— Type. Inspection: 114,0 g2,er i W N NE / , Address: 9y 5 S . 135 S , Date called: _ /)-5-97 Special instructions:. Date wanted: a..m. 11 at� p.m. Requester L G�� Phone No.: i 8(i7R INSPECTION RECOR -... - . Retain a, copy with per INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 , 11--o1(60 PERMIT NO. (206) 431 -3670 COMMENTS: Inspector: Date: ti /^ Approved per applicable codes. Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: is INSPECTION NO. CITY OFTUKWILA. BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Project: , .--1 Type of inspection: Address: Date called: ?9 Li5 S 1S 5�" 11 - IM - 1 7 Speciia instructions: Date wanted: l a c `) a rr i R equester: �JC)C..0 L � 24.,t Phone No.:.� 1 -86-1S COMMENTS: Date: Approved per applicable codes. ] $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Bivd., Suite 100, CaII to schedule reinspection. Corrections required prior to approval. Dci'l -01 toe PERMIT NO. (206) 431 -3670 Date: Project: .. 1 Type of inspection: Address: f- Zy(S . S. (3 Dat called: f r ro Special instructions: / Date wanted: / / r o�91- a.m. 0576 Requester: Phone No.: / INSPECTION NO. • CITY. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. COMMENTS: INSPECTION RECOR Retain a copy with penfttei ° coo PERMIT NO; (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspecti•n, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: A Type of inspection: C -ii.l JC, • '50041°'3 Address : . - Zs�S S• r3S Date called: if / /0 Special instructions: , , Date wanted: l r �to /97 en Requester: Phone No.: 0 2 ( 1 7,/' INSPECTION RECOR Retain a copy with per INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 .Approved per applicable codes. I PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: Inspector: I ( r Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt , No: : -- Date: Project: :;; .. (),s;,Ci Type of inspection: livAtc z1 .1 Address: .I _ Date called: 1/(d Special instructions:: Date wanted: / m. Requester: / " '1 Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: Date: f i i1 i I Receipt No.: INSPECTION RECOR Retain a copy with per I (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Date: Project: Siei JU40- j Type of inspectigni neiKkr..e ir Address: 7,,144..s 5 , i-ss-- Date called: II 4 - 11 Special instructions: Date wanted: 11 - 1 461° 'S Requester: Ir6t-Anrtit Phone No.: 74/ ,_ 1(49 INSPECTION RECOR Retain a copy with per INSPEC N NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter. Blvd., #100, Tukwila, WA 98188 • PERMIT NO.. (206) 431-3670 coymENTS: • I I Approved per applicable codes. Corrections required prior to approval. 12 4 $42.'' REINSPECTI N FEE REQUIRED. Prior to inspection, edrAust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: . Date: Project: � Type pgioe i. " = / Date / Addres t? called: Special instructions: Date wanted: /h 1 a Requester: Phone No.: INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Inspector: Approved per applicable codes. INSPECTION RECOR Retain a copy with per I PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: 3 $42.00 REINSPECTION FEE REQUIRED. Prior to ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ,.. ,:. Pr o j ect: Type of insp�6ction;"Q ‘�' 7z�e'`' . Add ress: y .9945 5.135 312te" as called: flo 9'7 Special instructions: .t.,�,t.c>�.n 7/ iu _i t c et AA Grr ne ,c - 1V,)1 . Date wanted: , . Gjjn 10 -31 '9 p.m. Requester: L. i Cu P-42-9 , 1 O Z Phone No.:) 85 - `ia' - Jy INSPECTION RECOR Retain a copy with per INSPECT! ' N NO. CITY 0 TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 (206) 4313670 COMMENTS: :i Approved per applicable codes. D9 "1=©l PERMIT NO. Corrections required prior to approval. $42.00 REINSPE or ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [ReceiPt No.: Date: Pry Typp� of inspectiion: Ad dress: e D called: Special instruc ions: i 1 quester: to wa teU: Cy INSPECTION RECOR Retain a copy with per INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 (206) 431 -3670 fE� Approved per applicable codes. C �.' MMENTS: Corrections required prior to approval. Inspector: (4 0e i t.,.3_ Date: ,a 1 El $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: U w Amt 1-t> A cck, (z4:1V-1 I -).rs 'Pt jN- w W ita-7 Lt u c� .. i t U i rsIG 1 Ctt STI ►.1 ( 7 (-t =scAr _ T 19� ctt.�U�.,._ yatiAL O . /qt • AP Roc. ( I t t r4. l►� i ( f 6-6' t c ) L - pI A-0. A S nt I NI - S - r6AC k... IS f4" LANI trd p j NAccu t-7 SN 1V4�c` w�T' er� rt - ci IJ sf- i-' Hn tns'E Tat l /L + oae M (F (1 1/0 r( r Sri r -1 Ci . 1 T /. A u_ /9r A,•oo, , ti o NI w I 1 � A- 3 (L� . SiFT6Au< - - t ri sT n F 714E frQ u I rtsi ) 0 rte.. wc.AL c 1* . -pals S11 AA --t,or l mat/... r I a(L. PJ 1 'NA t -L.1 I Na c co, (LA -1-E 4•1 Ii•t c .v4 . (Z4= - c3 -t.A t L:' . 7-M-ti 114 \ &":" s. Pc uo.►1 A- ■* 'Pt-A-r- CAS R..x S 1n 601) I iTC , ■ 114 Cal - j- IA- I?I?R.Q_JAt . ... Pro t: is.Tn c Rte-'. Type of inspecti spC '1Nos G ilsb 5 I3 - Date called: 7 - 5) - q1 Special instructions: � �te Wanted: p - 4 q i a .�� e er: L•AgR-( MuNbz hone No.: O 6 ` i_, i 2 Lf q tea+ ,usma VONZAI INSPECTION NO. `CITY OF TUKWILA BUILDING DIVISION 600 Southcenter Blvd., #100, Tukwila, WA 98 � Approved per applicable codes. Inspector: Receipt No.: INSPECTION RECOR[ `..' Retain a copy with per C:) PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: / $42.00 REINSPECTION FEE REQUIRED. Prior to inspec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: rr ..'�,_..... City of Tukwila John W. Rants, Mayor Steve Lancaster, Director December 6, 1999 Al Johnston PO Box 1899 Yelm, WA 98597 RE: Permit Status D97 -0160 2945 South 135 Street Dear Mr. Johnston: In reviewing our current permit files, it appears that your permit for the addition/remodel to an existing single family residence issued on June 20, 1997 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Department of Community Development Brenda Holt Permit Coordinator Xc: Permit File No. D97 -0160 Duane Griffin, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 41313670 • Fax (206) 4313665 June 6, 1997 City of Tukwila Department of Community Development Steve Lancaster, Director Mr. Al Johnston P.O. Box 1899 Yelm, Washington 98597 Dear Mr. Johnston: SUBJECT: LETTER OF COMPLETE APPLICATION Development Permit Application Number D97 -0160 Justice, Joyce 2945 S 133 St Sincerely, - 1/(dcti o 4- y Kelcie J. Peterson Permit Coordinator File: D97 -0160 John W. Rants, Mayor This letter is to inform you that your permit application received at the City of Tukwila Permit Center on May 12, 1997, was re- reviewed at the June 5, 1997, plan review meeting. Your application was determined to be complete. Your permit has begun the plan review process, you will be notified of any required corrections or when your plan is approved. If you have any concerns or questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 r:'�Yr;at2: 5 :5ai;ck'44AYKX1 DATE: SHEET NUMBER(S) SUBMITTED TO: '..'.�7tri!+.'RdY;7 •.tirg:'t7.4�:. ^hT<3,' rte+:' ftR1: Y+ Si' J$" �' Fi. ` N+' irRR :[�:SAat�a+:ru +:cilknt {tttE� SMCrtnA. xi (� 3 - R7 PLAN CHECK/PERMIT NUMBER: PROJECT NAME: <Il` Ge PROJECT ADDRESS: (9 9 5 1 3 J S q CONTACT PERSON: AL REVISION SUMMARY: • • "Cloud" or highlight all areas of revisions and date revisions. CITY OCTUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL D c - 7 - d l loo PHONE: 56 _0-- ")16:. -ova � <r> ��� i,o,!/ oaf kv ��. ►-eF€01 3 rr ��s fbur7alcri-i <Y) pct i'() '�oy)c) P ropd 0/ oar) i 7L/tm �l 0d 1997 PL HMI f CENTER CITY USE ONLY 3/19/96 May 27, 1997 Dear Mr. Johnston: City of Tukwila Department of Community Development Steve Lancaster, Director Mr. Al Johnston P.O. Box 1899 Yelm, Washington 98597 SUBJECT: Development Permit Application Number D97 -0160 NOTICE OF INCOMPLETE APPLICATION Justice. Joyce 2945 S 135 St This letter is to inform you that your permit application received at the City of Tukwila Permit Center on May 12, 1997 was determined to be incomplete. Before your permit application can begin the plan review process the following requirements from the Public Works Department must be met. Public Works Department: John W Rants, Mayor Contact Joanna Spencer, Development Engineer, at 433 -0179 if you have any questions regarding the following comments. 1. The site plan needs to show how the roof and foundation drains connect to the existing storm drainage system. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431-3672. SCOPE OF WOR 10' 1 < 1. 1 6' —4" X1 8' —8" ADDITION 2. REPLACE POST & PIER FOUNDATI N WITH PERIMITER FOUNDATION 3. REMODLE KITCHEN & BATH 1 EXISTING HOUSE 28' 51 EXISTING DECK Io SCALE 1" = 20' 145' 145' SITE PLAN LEQOARR11/2 OF 111E FAST 1/2 OF LOT 4. BLCOC ( 7, PIAT Cr revo 7R18.5 ME-15103 SQ. FT. EXISTING DRIVE CU OF TUKWILA APPROVED JUN 1 7 19 AS NU LO N) U) FILE COPY It SU'T T...j cmscc • nc,t authorize the violatI:i Li ar';. code or ercLfr. copy ..111 date c:=) — 9?-7 Permit No. Dam o( (o R EV1 S JON'S SEPARATE PERMIT REQUIRED FOR: 0 MECHANICAL ! i GAS PIPING CITY OF TUKWILA BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 2 1997 PERMIT CENTER of contractor's NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIO APPROVAL OF TUKWILA BUILDING DV: INOTE: REVISIONS WILL REQUIRE A N EV PLAN LY.. Ai L.,AY AL JOHNSTON DESIGN PHONE 206 SHEET: 1A OW\ ER: JOYCE JUSTICE ADDRESS:2945 S 135th ST SEATTLE, WA. i GENERAL NOTES 1. ALL WORK IS TO COMPLY WITH THE LATEST ADOPTED VERSION OF THE UNIFORM BUILDING CODE AND ANY APPLICABLE STATE, COUNTY OR LOCAL REGULATI ❑NS. 2. THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND IS TO NOTIFY THE DESIGNER OF ANY ERRORS OR ❑MISSI ❑NS PRIOR TO THE START OF CONSTRUCTION, 3. WRITTEN DIMENSIONS HAVE PRECE- DENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. 4. DESIGN LOADS: ROOF 25 PSF(LIVE LOAD) FLOOR 40 PSF STAIRS 100 PSF GARAGE FLOOR 50 PSF(2000 PT) DECKS 40 PSF (IF YOUR LOCAL AREA REQUIRES DEFF- ERENT DESIGN LOADS CONSULT WITH A LOCAL STRUCTURAL ENGINEER TO DETER- MINE THE APPROPRIATE REVISI ❑NS. 5. INSULATION: FOR OTHER THAN ELECTRIC RESISTANCE HEATING. ROOF R -30 ROOF (VAULTED) R -30 WALLS (EXTERIOR) R -19 FLOORS R -19 BASEMENT WALLS R -19 FOR ELECTRIC RESISTANCE HEATING ROOF R -38 ROOF (VAULTED) R -30 WALLS (EXTERIOR) R -19 FLOORS R -30 BASEMENT WALLS R -19 ALL ABOVE VALUES ARE A MINIMUM AND MAY BE INCREASED IF DESIRED. VERIFY WITH CONTRACTOR. 6 ANY ATTIC ACCESS DOOR SHOULD BE SHOWN WITH R -30 (R -38 WITH ELE. RESISTANCE HEATING) INSULATI ❑N ON IT SHOULD BE WEATHER STRIPPED, 7, HOT AND COLD WATER PIPES IN THE GARAGE SHOULD BE PROTECTED WITH R -3 INSULATION. THIS INSULATION SHOULD HAVE A FLAME SPREAD OF 25 OR LESS. 8. PROVIDE INSULATION BAFFLES AT EAVE VENTS BETWEEN RAFTERS. 9, ANY DOORS SEPERATING THE GARAGE AND THE DWELLING SHOULD BE A SLIT) WOOD CORE DOOR, 1 -3/8' THICK, SELF CLOSING, AND TIGHT FITTING. THIS SHOULD BE NOTED ON THE PLANS, 10. THE SHOWER SURROUNDS SHOULD BE SMOOTH, HARD, AND NONABSORBENT TO NOT LESS THAN 70' ABOVE THE DRAIN INLET. 11. THE GYPSUM BOARD BACKING USED FOR TUB OR SHOWER ENCLOSURES WILL BE WATER RESISTANT BUT NOT INSTALLED OVER A VAPOR BARRIER OR ON THE CEILING, 12, MINIMUM CEILING HEIGHT IS 7'7' EXCEPT 7'0" FOR KITCHENS, HALLS, BATHROOMS, AND TOILET COMPARTMENTS, 13. SMOKE DETECTORS WILL BE CENTRALLY INSTALLED ON THE CEILING OR WALL IN THE CORRIDOR AREA GIVING ACCESS TO THE BEDROOMS AND 'HOT WIRED' AND WITHOUT A DISCONNECTING SWITCH AND WITH BATTERY BACK -UP, 14. ALL INTERIOR STAIRWAY'S WILL HAVE A MINIMUM HEAD CLEARANCE OF 6'8' AND WITH A MINIMUM GUARDRAIL HEIGTH OF 36' AND INTERMEDIATE RAIL CLEAR SPACING LESS THAN 4', THE STAIR HANDRAILS WILL BE A MINIMUM OF 36' FROM THE FLOOR WITH STAIR HANDRAIL ENDS RETURNED TO THE WALL. 15. GALVANIZED METAL FLASHING WILL BE INSTALLED BETWEEN THE CONCRETE SLAB AND THE RIM JOIST AT ANY GARAGE SLAB, EXTERI ❑R PORCH, AND EXTERIOR LANDING. 16 INDIVIDUAL UNDERFLOOR CONCRETE PIERS SHOULD PROJECT AT LEAST 8' ABOVE EXPOSED GROUND UNLESS THE COLUMNS OR POSTS ARE TREATED WOOD, 17. WOOD GIRDERS ENTERING MASONRY OR CONCRETE WILL BE PROVIDED WITH 1/2' AIR SPACE ON SIDES, TIPS, AND ENDS UNLESS TREATED WOOD IS USED, 18, IF THE WATER HEATER HAS A NONRIGID WATER CONNECTION AND IS OVER 4' IN HEIGHT, IT SHOULD BE SHOWN ANCHORED OR STRAPPED TO RESIST EARTHQUAKE MOTION. 19, ANY GAS HEATING APPLIANCE SHOULD BE EQUIPPED WITH A LISTED SHUT -OFF ' DEVICE IN CASE OF PILOT OR IGNITION FAILURE, 20, DOMESTIC CLOTHS DRYERS WILL BE EXHAUSTED TO THE OUTSIDE. 21. ANY WALL BETWEEN THE GARAGE AND THE RESIDENCE WILL BE SHOWN WITH R -19 INSULATION AND 5/8' TYPE X DRYWALL. 22,A GROUND COVER OF 6 MIL BLACK POLYETHYLENE OR EQUAL WILL BE LAID OVER THE GROUND WITHIN THE CRAWL SPACES AND OVERLAPPED A MINIMUM OF 12' AT ALL JOINTS. 23. BLOWN OR POURED INSULATION IN THE ATTIC MAY BE USED WHERE THE CEILING SLOPE IS NOT MORE THAN 3/12 AND WHERE THERE IS AT LEAST 30' OF CLEAR SPACE. 24. WHERE UNDERFLOOR VENTS ARE INSTALLED IN THE RIM JOISTS, A BAFFLE SHALL BE PROVIDED BENEATH THE INSULATION, SLOPED AT 30 DEGREES FROM THE TOP OF THE VENT. 25. SHOWERS SHOULD BE EQUIPPED WITH FLOW CONTROL DEVICES TO LIMIT TOTAL FLOW TO A MAXIMUM OF 3 GPM PER SHOWER HEAD. 26. WATER HEATERS SHOULD BE LABLED AS COMPLYING WITH NAECA 1987, 27 ELECTRICAL WATER HEATERS SHOULD BE INSTALLED ON AN INCOMPRESSIBLE INSULATION (R -10 MINIMUM) IF LOCATED IN AN UNHEATED SPACE SUCH AS A GARAGE. 28. FOOTINGS ARE TO BEAR ON UNDISTUR- BED LEVEL SOIL DEVOID OF ANY ORGANIC MATERIAL AND STEPPED AS REQUIRED TO MAINTAIN THE REQUIRED DEPTH BELOW THE FINAL GRADE. 25. CONCRETE TO DEVELOP A MINIMUM OF 2500 PSI AT 28 DAYS WITH A MINIMUM OF 5 SACKS OF CEMENT PER YARD AND A MAXIMUM SLUMP OF 4 INCHES. 30. CONCRETE SLABS TO HAVE CONTROL JOINTS AT 25 FEET MAXIMUM INTERVALS EACH WAY. 31. CONCRETE SIDEWALKS TO HAVE 3/4 TOOLED JOINTS AT 5 FOOT O.C. 32, EXCAVATE SITE TO PROVIDE A MINIMUM OF 18' CLEARANCE UNDER ALL GIRDERS 33, ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED OR PROTEC- TED WITH 55# ROLLED ROOFING, 3. WATERPROOF BASEMENT WALLS BEFORE BACKFILLING PROVIDING A 4' PERFOR- ATED DRAIN TILE BELOW THE TOP OF THE FOOTING. 35, FOUNDATI ❑N PLATES SHOULD BE BOLTED TO THE FOUNDATION WITH NOT LESS THAN 1/2' STEEL 'J' BOLTS 10' IN LENGTH EMBEDDED 7' INTO THE CONCRETE AND SHOULD BE SPACED TO RESIST THE LATERAL LOAD WITH AT LEAST 2 BOLTS PER PIECE AND 1 BOLT WITHIN I FOOT OF THE ENDS OF EACH PIECE, 36, EACH BEDROOM TO HAVE A WINDOW OPENING OF 5,7 SQ. FT. WITH A MINIMUM WIDTH OF 20' AND A SILL LESS THAN 44' OFF THE FLOOR, 37, ALL WINDOWS WITHIN 18' OF THE FLOOR AND WITHIN 24' OF ANY DOOR ARE TO HAVE TEMPERED GLAZING. 38. SKYLIGHTS ARE TO BE GLAZED WITH TEMPERED GLASS ON OUTSIDE AND LAMINATED GLASS ON INSIDE (UNLESS PLEXIGLAS), GLASS TO HAVE MAXIMUM CLEAR SPAN OF 25'. SKYLIGHT FRAME IS TO BE ATTACHED TO A 2X CURB WITH A MINIMUM OF 4' ABOVE ROOF, 39. ALL TUB AND SHOWER ENCLOSURES ARE TO BE GLAZED WITH SAFTY GLASS, 40. ALL EXTERIOR WINDOWS ARE TO BE DOUBLE GLAZED AND ALL EXTERIOR DOORS ARE TO BE S ❑LID CORE WITH WEATHERSTRIPPING. PR ❑VIDE 1/2' DEADB ❑LT LOCKS ON ALL EXTERIOR E PFIF-6,11-ffg DOORS AND LOCKING DEVICES ON ALL DOORS OR WINDOWS WITHIN 10 ' VERT- ICAL OF GRADE. PROVIDE PEEP -HOLE 55' -66' ABOVE FLOOR ON EXTERIOR DOORS. 41. PROVIDE COMBUSTION AIR VENTS WITH SCREEN AND BACK DAMPER FOR FIRE- PLACES, WOOD STOVES AND ANY APPL- ANCES WITH AN OPEN FLAME. 42. BATHROOM AND UTILITY ROOMS ARE TO BE VENTED TO THE OUSIDE WITH A MINIMUM OF A 50 CFM FAN. RANGE HOODS ARE ALSO TO BE VENTED WITH A MINIMUM 100 CFM FAN. 43. ALL EXTERIOR WALL OPENINGS AND BEARING WALL OPENINGS TO HAVE 4X8 HEADERS UNLESS OTHERWISE NOTED ON THE PLAN. 44. JOISTS THAT ARE ATTACHED TO FLUSH BEAMS ARE TO BE HUNG WITH SIMPSON U -2?_0 OR EQUAL. 45. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS. 46. LUMBER SPECIES: POSTS, BEAMS, HEADERS JOISTS AND RAFTERS. B- SILLS, PLATES, BLOCKING, BRIDGING, ECT. C-S T UDS D -PLY SHEATHING WALLS E -PLY SHEATHINF ROOF F -GLU -LAM BEAMS RECEIVED CITY OF TUKWILA MAY I 2 199 PERMIT CENTER #2 DF #2 HEM /FIR STUD GRADE 1/2 CDX/ 7/16 OSB 5/8 CDX / 7/16 OSB Fb- 2400,DRY ADH, ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REP- RESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF AL JOHNSTON /AL JOHNSTON DESIGN AND WERE CREATED EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH, THE SPECIFIED PROJECT, NONE OF SUCH IDEAS, DESIGNS,ARRANG- MENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF AL JOHNSTON /AL JOHNSTON DESIGNS, WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. - a a rc V) z V) Li z F- z I U 0 SCOPE OF WOR 1. 16' -4 "X18' -8" ADDITION 2. REPLACE POST & PIER FOUNDATION WITH PERIMITER FOUNDATION 3. REMODLE KITCHEN & BATH uJ w J N b to BEDROOM #1 cc m� s I 2'8" X3'4 GLASS BLOCK CARPET 11' -3" 9'-11" BATH 50 FAN O 10' -0" S •KE If 2 '6" X6'8" 19' -1" 0 w S ' U) V u) O 0 C., 0 J 0 l 0 0 I kj to Igg CARPET -{ FIXTURE $ SWITCH • DUPLEX OUTLET 220 OUTLET O FAN • SMOKE ALARM 11' -8" 5'- 0"X4'— IY'SLIDER BEDROOM #2 SM KE M $ SMOKE ALARM LIVING ROOM SCALE 1/4" = 1' -0" 51' -4" w w I C FLOOR PLAN 5' -0" w W ce NOTE: ALL HEADER MATERIALS ARE #2 D.F. 4 "X8" UNLESS OTHERWISE NOTED 4" —0" X3' -6 "SLIDE R x KITCHEN VINYL to z 00 cri I W I 21' -5" 9' -9" 5'- 0"X4'- 0"SLIDER Swim AREA i wim ? a. CARPET C' R4tvos, tOOc9A. Mtg. progivutticiE ' # t44. (d, Lizr►A E(C4. 16' -4" EXISTING DECK ADDRESS:2945 S. 135th ST, S 6' -9" =ATTL AL JOHNSTON DESIGN P -0\1- 206 - 399 -9295 SHEET: 2 OWNER: JOYCE JUSTICE CITY OF TUKWILA APPfiOVED le:L JUN 1 7 1H7 WA. ice i �� RECEIVED CITY OF TUKWILA PERMIT CENTER 4" TO 15 FELT SIDING 7/16 OSB R-19 INSULATION R-19 INSULATION 1/2" DRYWALL 3/4" T&G PLY i i 14 F ri S I H GRADE ----- 111----E111 2— REBAR CONTINOUS 1 111 ! 111 It .1. ____... 0 .0 01.011.7.0 12. (7 11 , I 0 0 ° 0 0 o 0 o • • , 0 AND 4 4RE—BcrAR O.C. 18" H 0 0 ,C R .ZE_ RTICI& 6' TOP & BOTTOM 6 MIL POLY — 1 II I I I HI 11 III 1 111=111=111=111=1 IL=-1-111 cA 111= .. . , I i vt 1 FOU k DATIO \ DETAIL ALE 1"= —0" PRESSURE TREATED 2" X6" SILL PLATE 1/2" X10" ANCHOR BOLTS FLOOR JOIST 51' —4" LIVING ROOM eX• ONDA SCALE 1/4" = 1' —0" AL JOHNSTON DESIGN OWNER: JOYCE JUSTIC ADDRESS:2945 S 135t P ST S 16'-4' 16 EAT ON PLAN , 1, r Foy_ c'bv-EA. MIN VFal): eiF 0Egis_ t_ocATE EoEtsui ON — SID:ES O* Tr COALL -77 WA. CITY OF TUKWILA APNO0F:)). flH "j 1:]Z7 1143/237,90.6.21901,1 RECEIVED CITY OF TUKWILA PERMIT CENTER ONE 206-399-9295 SHEET: . A ..... E.K ___ .— _ . _ '; 1 1 Imi ,,,',. .— 1 I I I 1 I 1 I :4- 7 I I r . 1 ii 1 1 18X1 X8 CONC PADS Wi IMPSON PB44 4X4 — r - 11 7/8" TJI 16" O.C. TYP. BKTS. @ TYP, POSTS I I I j . F I 4" TO 15 FELT SIDING 7/16 OSB R-19 INSULATION R-19 INSULATION 1/2" DRYWALL 3/4" T&G PLY i i 14 F ri S I H GRADE ----- 111----E111 2— REBAR CONTINOUS 1 111 ! 111 It .1. ____... 0 .0 01.011.7.0 12. (7 11 , I 0 0 ° 0 0 o 0 o • • , 0 AND 4 4RE—BcrAR O.C. 18" H 0 0 ,C R .ZE_ RTICI& 6' TOP & BOTTOM 6 MIL POLY — 1 II I I I HI 11 III 1 111=111=111=111=1 IL=-1-111 cA 111= .. . , I i vt 1 FOU k DATIO \ DETAIL ALE 1"= —0" PRESSURE TREATED 2" X6" SILL PLATE 1/2" X10" ANCHOR BOLTS FLOOR JOIST 51' —4" LIVING ROOM eX• ONDA SCALE 1/4" = 1' —0" AL JOHNSTON DESIGN OWNER: JOYCE JUSTIC ADDRESS:2945 S 135t P ST S 16'-4' 16 EAT ON PLAN , 1, r Foy_ c'bv-EA. MIN VFal): eiF 0Egis_ t_ocATE EoEtsui ON — SID:ES O* Tr COALL -77 WA. CITY OF TUKWILA APNO0F:)). flH "j 1:]Z7 1143/237,90.6.21901,1 RECEIVED CITY OF TUKWILA PERMIT CENTER ONE 206-399-9295 SHEET: I c\ MANUFACTURED TRUSSES 24' D.C. TYP. 1/2" CDX PLY OD 7/16 OSB — 5/8" T 1 -11 SIDING OR 1/2" CDX W/ BEVEL SIDING 15# FELT PAPER GRADE CEDAR SHAKES --� z 12'X12' SCREENED VENTS 6'0' D.C. EACH SIDE STRUCTURAL A SCALE 1/2" = 1' -0" I 1/2' DRY WALL TYP & PVA PAINT 1/2' DRY WALL TYP & PVA PAINT 11 7/8" TJI 16" O.C. TYP R -30 INSULATI ❑N 3/4 T &G PLY R -19 INSULATION 16' O.C. TYP. bo 6" MIL POLY GROUND COVER 12 PITCH \ D EO U \RATION PLA\ 4 12" NOTE SOIL 2000 PSF MIN. DESIGN FLUID PRESSURE DO PCF 3 -2' SCREENED HOLED EACH BLOCK 1/2" PLY SOFFIT W /4" X8" SCREENED VENTS 4' -0' 0.C. R -19 INSULATION ALL 2X6 STUDS 16' D.C. TYP, 2"X6" HEM /FIR PLATE 2"X10" RIM JOISTS — REATED 2"X6" SILL PLATES 1/2" X 10" ANCHOR BOLTS 6' -0" O.C. & WITHIN 12" OF PLATE ENDS. 2— #4 REBAR TOP & BOTTOM UT CITY 1u;,4s t .1,ii11) RECEIVED CITY OF TUKWILA PERMIT CENTER AL JOHNSTON DESIGN PHONE 206- -399 -9295 ! SHEET: - OWNER: JOYCE JUSTICE ADDRESS:2945 S. 135th ST SEATTLE WA L FT ELEVATI O \ FRONT (EAST) X IL NATION (NORTH) EXISTING DECK REAR EL AL JOHNSTON OWNER: JOYC ADDRESS:2945 GLASS BLOCK IVATIO\ (SOUT 1 RIG HT DESIGN P JJSTIC S. 135th ST ELEVATION CITY OF TUKWILA APP'ROV iD SEATTLE WA. 1ST) RECEIVED 4 .217 CITY OF TUKWILA E PERMIT CENTER ONE 2O6 -399- -9295 , SHEET: 3