Loading...
HomeMy WebLinkAboutPermit D97-0176 - BOEING #21-04 - RESTROOMSCity of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Contractor License No: BOEINC*294ML Permit Center Authorized Signature: Signature:___ Print Name: DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. (206) 431 -3670 Parcel No: 102304 -9069 Permit No: D97 -0176 Address: 3417 S 120 PL. Status: ISSUED Suite No: Issued: 06/10/1997 Location: Expires: 12/07/1997 Category: ACOM Type: DEVPERM Zoning: MIC /L Const Type: V -N Occupancy: WAREHOUSE Gas /Elec.: UBC: 1994 Units: 001 Fire Protection: SPRINKLERS /AFA Setbacks: North: .0 South: .0 East: .0 West: .0 Water: 125 Sewer: .VAL ' VUE Wetlands: Slopes: Y Streams: OCCUPANT BOEING #21-04 3417 S 120 PL, SEATTLE, WA 98124 OWNER SABEY CORPORATION 201 ELLIOTT AVE. WEST, SUITE 400, SEATTLE WA 98119 CONTRACTOR BOEING COMPANY P.O.. BOX 3707, M/S IF -09, SEATTLE, WA 98124 CONTACT . GARY TALLER Phone: 206 -2975 P.O. BOX 3707, M/S 46 -87; SEATTLE, WA 98124 ****************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: EXPAND MEN'S AND WOMEN'S BATHROOMS. *********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 32,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) •Eng.'Appr: Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: No: Size(in): .00 Flood Control Zone: Hauling: Start Time:. . End Time: Land Altering: Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start Time: End Time: Sanitary Side Sewer: No: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: . Public: ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT. FEES: $ 685.54 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** _ Date �d' I ) I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development per it. Date: 4 /f.7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 3417 S 120 PL Suite: Tenant: Type: DEVPERM Parcel #: 102304 -9069 • CITY OF TUKWILA Permi t'•No: D97- 0176 Status: ISSUED Applied: 06 /02/1997 Issued: 06/10/1997 ***** k*• k** k• k***• k* k*• k* k**• k• k* k• k k* 4*• kk**• k k*• k4• k• k*• k• Mlkk k• k4 . Mk•k1Y•k•k *•kk•k * **•k *•kkkk•k4 Permit Conditions:. 1..PRI0R TO FINAL SIGN OFF APPLICANT SHALL SUBMIT KING COUNTY NON- RESIDENTIAL SEWER USE CERTIFICATION TO PUBLIC WORKS FOR PROCESSING. 2 No changes will bema'der.' „ . o' the. plans 'unless approved by the Architect or Engineer and th:e,YTukwila Building Division. 3. Plumbing permits s - hall tie ob:.tained through the e a.tle - King County Depar of ., Pub:l is Health:: P 1 umbi ng . wi l l`; be_ insp.ected4b`y;.°that agency. includina all gas piping' (2 "96 -4722) i° Electri per be ob through the Washin State ,Division of Labor and`4ndustr. es and all electrica work ,Karl l •be inspected by': that agency (248- 6630) . 5 All meonanicai' work" sha;l.l''be under' separate permit issued ,by the t `C,i1i v . Allfipermits inspection recotr,ds, and approved plans shall availabl a ,t the jobsite prior to. - the. start of any con tr „unction.`” These documents! are to;;be siiaintained and a'vai ab,l,e`funtil - fi;nal:-•in:p i,s.. granted. 7. Any'`new c 1 ing gr.i.d and l'i +ght' fixture installation 'is•: rec cured t_o meet latera.brecing,"-re',quir ` e.ments for S l• • S e ismic Zone 3. 8. Partitio walls attached to ceiling ,grid. must be la bra ,.:if. over. eight " feet in - ,length 9. An_y e`xpo,s;ed insulation. backing'- material shall have a,~ F°-lame. Spread Rating of 25 or less. and material• shall bear identi - =' fication showing the fire performance '.rati.ng thereof 10. A•l'l construct i on s,t be done in conformance with : ,approved plans ' an,d requirements of the Uniform Building. " Code (1994. iEdition) as amended;.: Uniform Medhan'ical Code. (1994, Edition). and Wash :ington :',State Energy Code (1994 Edition) 11. Validity`of Permit. The issuance of a permit or approval of plans, speci;f-ication., and computations shall not be con- strued to he'-a:-permit for, Or an approval of, any ,Violation of any of the •pr?ov i s i ons of: the:. building code or of 'any other ordinance 'of; the jurisdiction. • No per.m'it,presuming to give authority to violate orb, cancel the_provi of this code shall be valid. 12. VENTILATION IS REQUIRED FOR ALL NEW ROOMS AND SPACES OF NEW OR EXISTING BUILDINGS' IN. CONFORMANCE WITH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, CHAPTER 51 -13 WAC. Project Nameffenant: ROE 1NG BLDG. y a)-4) Value of Construction: t J Tax Parcel Number lo.Q oil — ''c q Site Address: ..... 3y/ �. / 2.Q State /Zip: '� �L�« Property Owner: THE BOEING COMPANY Phone: Street Address: P. n. BOX 3707 MIS 46 -87 SEATTLe 6 #: Contact Person: GARY TALLER/ P e: hr -544 -2975/ Street Address: P.O. BOX 3707 M/S 46 -87 CI�y State /Zip: SEATTLE, WA 98124 Fax #: 206 -544 -2854 Contractor: \ Phone: Street Address: City State /Zip: Fax #: Architect: 'A e � l � J Kt N T v Phone: s _ .2 sq Street Address: City State /Zip: Fax #: Engineer: • Phone: Street Address: City State /Zip: Fax #: Description of work to be done: E .- - -- rfavA MC,r, G. (Ai 0 ►•+••tom \ ZPAL/ UO v --. S Existing use: ❑ Retail ❑ Restaurant ❑ Multi - family 21. Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church 'Manufacturin ❑ Motel /Hotel ❑ Office ❑ School/College /University ❑ Other Will there be a change of use? yes ❑ no If yes, extent of change: (Attach additional sheet if necessary) Fromm 1 40 Fa, c kettn G' f'µr%1 Pa.4 ) Will there be rack storage? yes El no Existing fire protection features: El sprinklers El automatic fire alarm El none ❑ other (specify) Building Square Feet: 1 13 / 72"( existing Area of Construction: (sq. ft.) SC Z "/ Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list•of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material a ety Data Sheets Commercial / Multi - Family Tenant Improvement / Alteration Permit Application ❑ Channelization /Striping ❑ Land Altering 0 Cut ❑ Sanitary Side Sewer II: ❑ Storm Drainage ❑ Water Meter /Exempt II: ❑ Water Meter /Permanent # ❑ Water Meter Temp ft ❑ Miscellaneous Date application accepted: C'1'PEIlMIT.DOC 7/9/96 CITY 01- j IKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC IL';P„LANREVIEW'OF THEFOLLOWING: `, (Additional reviews may be determined by the'Publlc Works Department) ' ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling cubic yds. JOB N ❑ Street Use Size(s)• Size(s)• Size(s)• In -a- ai 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Est. quantity: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Data application expires: la - a-91 gal Schedule: Application l: • • by: (Initials) .I: BUILDING OWNER •R AUTHORIZE 4 - T: Signature: / 0i- Date: Print name: GARY T LER Phone:206- 544 -2975 Fax tt:206- 544 -2854 Address p -n- BOX 3707 M/S it6 -87 City /State /Zip SEATTLE, WA 98124 ALL COMMERCIAL/MULTI -FA!.. Y TENANT IMPROVEMENT /AL ATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas • 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT ! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE SjATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 7/9/96 Project: ` J C ,f ' w � ��) i s r T�y�e� of ins ec�'q� • ` I a V—LYk Address: Date called• Special instructions: S ` ', 30 cL,r- Date wanted:__ 11 ` -L1-1 p.m. Req�ue� k. Pho N o.: . 11.4 a. • INSPECTION RECORD Retain a copy with permit INSPECTION NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: 4- A Inspector Receipt No.: Date: Corrections required prior to approval. (2 431 -3670 Date: 3 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fe: must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project: b Type of inspect' ` o V , 0 Ai I , Address,_ (i , [20 n I , Date called: cf.... Special instructions: 1/. 7; () 1 4 t42 (,,. 6° 1� Date wanted: q / .. , a.m. Requester: S Phone No.: ti INSPECTION NO.�: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspecto � AA M Date: e'"/ G� $42,00 REINSPECTUON 'PEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Ca Ito schedule reinspection. Receipt No.: Date: INSPECTION RECORD /* Retain a copy with permit Corrections required prior to approval. ori 'b ip PERMIT NO. e (206) 431 -3670 (95-5- --gzd Project: rb .c.slc , rvg., 7) . ( 4. Type of inspection: 9 4stv..,A1 v.s e Address: -1/4 .2 • I e \— Date called: Special instructions: Date wanted: 91 1 ic, a.m. Requester: Phone No.: i)...'043r414021211241111912=1.111311 4. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 per applicable codes. PERMIT NO. (206) 431-3670 *r Corrections required prior to approval. COMMENTS: Inspector: Date:01 El $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: '• ' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector• INSPECTION RECORD Retain a copy with permit 1,16 5 Date: • ,1 " brit PERMIT NO. (206) 431 -3670 Type of inspection: to ca led: roject: , a `. — n So . t a.0trPl , Special instructions: wantt a.m.` p.m. quester: r 1 C Rho 'D (i`2) Corrections required prior to approval. Pl $42.00 REINSPECTIO v FEE R tat ORED. Prior to inspection, fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: In1 (10 q ..,} LL 5 5 --T . -1)Q . O 1 tjF ' 11).... t-vvyAlt,I 1 ,4 PfLwM . 2 A00 sett -‘ )Jiiizr..4 t G LA ,AG SPACc . c c ME- WAti4--S ACC" sw-% G w -a - litArvsF1%- t s t -WA-US TO ∎""1- - s10 $1 1. Glt., LakA6LA1 U , IJ da1sT-s - Rk t'1'` 80th— c lc pr; 10 Nvic . sPR 0 t.)(. . Ai-49 f cc I LA C LA-1 e P 'e ,..J�C ct rlc1 2,»I-� � Type of inspection: Address: Date called: . ict J Special instructions: 2 -` e Lk (---0\ V ' Date wanted: CI t P.m. Requester: 1 f ; j , ✓`Q'� acv` c - r\ Phon No.: 6 -• )--k V 21 az I I INSPECTION RECORD Retain a copy with permit INSPECTION NO. . , CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Approved per applicable codes. [Corrections required prior to approval. Inspector: J Dater $42.00`i INSPECTION FEE REQUIRED. Prior to inspdcti fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: /�'14n 3i�irtt; ltib? �' �? a t�, �i�CtY ,v+n1':a5��'`6�`7�7ex�'9tl1* ��.' t OVtk4y '"�e"sYi'a:w7+G` . i<tyi'..� .��,f ..v. 4-..tNt;', :id x47, City of Tukwila Fire Department Project Name , �J"� 11ar - Q4' TURWILAtFIRE•DEPARTMENT FINAL APPROVAL FORM' Address 3 +} S I ACT 8 : 1 -' P L Retain current inspection schedule Needs shift inspection Approved without correction notice FINALAPP.FRM Approved with correction notice issued Sprinklers: Fire Alarm: \- L Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature T.F.D. Form F.P. 85 John W Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. 111 13 \1 ^ C'•X \ Date Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 ********•* kh** k* kk*****l rkkk**** kk* Ak*** k* k* ,kAk•4k***4***kkk:lAkk••1'•k CITY OF.:1•UKWILA. WA 1'Ulf /6NiT *kk ** Ask *kk* **.k**** kk• *` k Akkkk •k **kk *kAkl:4****Ak.ki'kk* 1'RHNSMIT Number.: 89700597 Amount: 417.25 06/12/97 00:52 Payment Method: CASH Notation: BOEING !nit: 66LB Permit No: D97 -0176 Type: DEVPERM DEVELOPMENT. PERMIT Parcel. No: 102304- 9069 Site Address: 3417 S 120 PL Total Fees: 6 3 . ;4 This Payment 417.25 Total ALL Pmts: 605.54 Balance: .00 ** *A *,.*********•********* *k* *•k ******k ****.A****k*k** * *A ** ****Ai *** Account Code 000/322.100 000/386..904 Description BUILDING.- NONRES STATE BUILDING SURCHARGE Amount 412.75 4„"0 06/12 971.7 TOTAL 417..21:z.:. ................,...,.......-...„.-„ * * *•A *A* * *0 * * * * *•k *•A *A k * * * * *a1 * * * *A *• kit***** ***•k•k**A* ** ***A•AAA4 * CITY: OF TUKWILA. WA —^( '"� ( TRANSMIT * * * * * * * * * *4 * * * *13 **•AIT1* `•n1l1 * •� �� �E�c * * * * **** * *** * * * * *** * **** TRANSMIT Number: R 9700590 Amount: 268,29 06/02/97 15 :19 Payment Method: .CASH Notation: BOEING Init SLB P!rm'.it: Nue `a97—017f Type;' DEVPERM DEVELOPMENT PERMIT Parcel No,: °:102304 --9069 :"Sitc':Address:`'3417' PL This .. Payment: Total Fees: 260..29 Total. ALL Pmts: Ba1anre: 685 w 54 268.29 417.23 ****•*** * * * *•Ak * ** * ** *•k *A ** *** *It * *A*1 *A* A* * * *k * *•k *• *A. **. * * * *•A *. ** * * *•k Account Code Description Amount 000/345,.530 PLAN. CHECK - NONRES 268.29 -.4\90 06/02.9717 TOTAL 68.29 REVIEWERS INITIAL Py* Coord%n*ov cef# PLAN REVIEW / ROUTING ACTIVITY NUMBER D97 -0176 PROJECT NAME BOEING 121 -04 DEPARTMENT: P G DIVISION DIVISION �� PREVENTION ❑ DIVISION PUBLIC WORKS ( y� ► (p-3-ep CTURAL ❑ PERMIT COORDINATOR U PtwC CQloula1 _ �J DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE ❑ COMMENTS TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) I APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED ❑ REVIEWERS INITIAL C:ROUTE -F DATE DATE DATE DATE 6/02/97 DUE DATE 6/03/97 NOT APPLICABLE ❑ DUE DATE 6/17/97 APPROVED ❑ APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ I 1 DUE DATE APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) 0 (Certification of occupancy required. YC�1:: ut:' ��A.+. M. o..f• GI' IL :W�M':HC'.iW;AihW.'1Rfi1!M(Yy,(; VrM_ I ACTIVITY NUMBER D97 -0176 PROJECT NAME BOEING #21 -04 DEPARTMENT: BUILDING DIVISION • PUBLIC WORKS DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE COMMENTS REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F Ott wri L (r• NOT COMPLETE APPROVED n APPROVED W/ CONDITIONS CORRECTION DETERMINATION: PLAN REVIEW / ROUTING SLIP FIRE PREVENTION PLANNING DIVISION STRUCTURAL El PERMIT COORDINATOR 0 t DATE DATE DATE 6/02/97 DUE DATE 6/03/97 NOT APPLICABLE Q TUES /THURS ROUTING: PLEASE ROUTE NO FURTHER REVIEW REQUIRED ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) DUE DATE 6/17/97 NOT APPROVED (attach comments) DATE 6 I / ? l c DUE DATE APPROVED' l J APPROVED W/ CONDITIONS El NOT APPROVED (attach comments) 0 (Certification of occupancy required, ) t33W'+I:ut :lEi ^.tk:ta.4w'. wiA'i+Y.'�Ya+xVIR.VaMa.JR(MAW ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION P PUBLIC WORKS 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE [ NOT COMPLETE COMMENTS TUES /THURS ROUTING: PLEASE ROUTE NO FURTHER REVIEW REQUIRED E ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED n REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP L D97 -0176 BOEING 121 -04 FIRE PREVENTION ■ PLANNING DIVISION STRUCTURAL El PERMIT COORDINATOR Q �1 l CORRECTION DETERMINATION: APPROVED n APPROVED W/ CONDITIONS s— er..p..wr....wwfMCI— DATE DUE DATE 6/03/97 NOT APPLICABLE DATE 6/02/97 I I DUEDATE 6/17/97 APPROVED W/ CONDITIONS 5 NOT APPROVED (attach comments) fl DATE t DATE DUE DATE NOT APPROVED (attach comments) (Certification of occupancy required. ) ide.MVaa+. �Mw�.W ..� 4z'z..wtw�.0 fa -M� rev=W r.'}iAtrMr W �i+Mt W AtwYCmMkN.KH tu. W 4t ACTIVI'T'Y NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION T PUBLIC WORKS COMPLETE COMMENTS REVIEWERS INITIAL, REVIEWERS INITIAL APPROVED REVIEWERS INITIAL C:ROUTE -F L idt N. e.V. PLAN REVIEW / ROUTING SLIP D97 -0176 BOEING #21 -04 FIRE PREVENTION E STRUCTURAL n I DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE CORRECTION DETERMINATION: TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED E ROUTED BY STAFF rn (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) I APPROVED W/ CONDITIONS DATE Z.:10? APPROVED n APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) E DATE DATE 6/02/97 PLANNING DIVISION • PERMIT COORDINATOR Q DUE DATE 6/03/97 NOT APPLICABLE DUE DATE 6/17/97 DATE DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) 4 I ACTIVITY NUMBER PROJECT NAME DEPARTMENT: COMPLETE COMMENTS REVIEWERS C:ROUTE -F REVIEWERS INITIAL • nn rt4 •$ ){ e�i4 :A'�7f:.ANSf.'tr•�,^.y.+sM4r. PLAN REVIEW / ROUTING SLIP D97 -0176 BOEING 121 -04 BUILDING DIVISION Cl FIRE PREVENTION C PLANNING DIVISION U PERMIT COORDINATOR PUBLIC WORKS STRUCTURAL 4 DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE TUES /THURS ROUTING: PLEASE ROUTE ROUTED BY STAFF �� �. routed b taff, make copy to master file & enter Sierra.) DATE APPROVALSOR CORRECTIONS: (ten days) DUE DATE 6/17/97 APPROVED 1 APPROVED W/ CONDITIONS E[ NOT APPROVED attach comments) C f DIA e, ut.e.,) kti k--re-r Usk Calk '(..,,$)-P-1'9-,_ . REVIEWERS INITIAL cv� DATE 6/ r CORRECTION DETERMINATION: DUE DATE APPROVED C APPROVED W/ CONDITIONS DATE DATE 6/02/97 DUE DATE 6/03/97 NOT APPLICABLE NO FURTHER REVIEW REQUIRED C I NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) CITY OF TUKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL DATE: 7/2 iI/1'7 PLAN CHECK/PERMIT NUMBER: 4 / 7 PROJECT NAME: BOEING DEFENSE & SPACE GROUP PROJECT ADDRESS: 2 Li/7 x.20 2.14 PL. . CONTACT PERSON: GARY TALLER REVISION SUMMAR tt rr n v\s4-e(Acho ,n Kirke C — i - 3 12k 1 - %I n/ av,r.A QQ cc 61 ' F; a(A ©rce CL-L a �s 7/a/7 SHEET NUMBER(S) 1 M "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO• •■••Cei 6 Bldg. Planning FIrr C t\(4,i i-DLL) PHONE: 206 -544 -2975 Public Works pxnpivFn CITY OF TUKWILA collead ENTER 5 k CITY USE ONLY Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtubs and /or shower 4 2 Dental units or lavatory 1 1 Dishwasher 4 2 Drinking fountain (each head) 1 1 Hose bibb or sill cock 5 3 Laundry tub or clotheswasher 4 2 Sink, bar or lavatory 2 1 9 b Sink, clinic, flushing 10 10 Sink, kitchen 4 2 • Sink, other 4 - 2 , ], Sink wash, circle spray 4 4 ' Urinal, flush tank 3 3 Urinal, pedestal • 10 10 Urinal, wall or stall 5 5 ,2,. 10 Water closet tank 5 3 . Water closet, flush valve 10 6 S .50 Owner's Name _IHE__BOF T N_G C'?MI?ANY (Last, First, Middle Initial) Property Legal Address: Subdivision Name Lot # Subdiv. # Block # Property Street 4 317 S 120 PL . Address BLDG. 21 City, State, Zip T 1 1 Owner's Phone Number ( 0 6) =- 5 44- 2 9 75 Owner's Mailing Address: (if different from above) • _BOFTNG DFFFNSF F,_S.BA(F G ?OUP P.O. BOX 3707 MS 46 -87 SEATTLE, WA 98124 -2207 A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Total Fixture Units Residential Customer Equivalents (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units For K466664 utt •Account 1058 (Roy. 11/96) 20 4. RCE White - King County Monthly Rate Six Month' Due A B Date Non - Residential Sewer Use Certification (To be completed for all new sewer connections, reconnections or change of use of existing connections. m "' "' This form does not apply to repairs or replacements of existing sewer connections.) Pursuant to King County Ordinance No. 11034, all sewer customers who establish a new service which uses metropolitan sewage facilities after February 1, 1990 shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council but is limited by state law to $10.50 per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi- annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 664 -1740. (Please print or type) PropertyTaxlD# 1n730.4 -90f9 Building Name (if applicable) 21-04 Party to be Billed (if different from owner) Party's Mailing Address: (if different from property address) !3 ^ETNG DEFENSE S SPACE GROUP P.O. BOX 3707 MS -87 SEATTLE, WA 98124 -2207 or Property Contact Phone # ( ) City or Sewer District lide1 Date of Connection Side Sewer Permit # 17-6 B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /day Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) 187 C. Total Residential Customer Equivalents: (add A & B) = RCE ...+^. n. � + :vim:mt;nNietn'''ent.orza , ,WI' I iet5461 r er Wj�; i`' '..fMC'MWTP.1?"S'57i.f. H -i3 RCE I certify that the information given is correct, I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner/ Representative Print Name of Owner/ Representative (7Clr q. 1 Yellow - Local Sewer Agency Pink - Sewer Customer is z2 v,'15'bF6CailSflie "4; • City of Tukwila Fire Department Jaime 2.,19197. Fire Department Review . Control # D37- 0176 „vtseft Re: T.I. at Boe,%3G . J*49t0q, : 3'l/ - ] 5 i . 0 / Dear Sir: •JJ The attached set of building. plans have been reviewed by The Fire Prevention'Bizreau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 John W Rants, Mayor Thomas P. Keefe, Fire Chief C City of Tukwila Fire Department Page number 2 halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the ihspection. °_tom is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 20,0 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 57.5-4439 • ` t.M rmtme City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) Internally illuminated exit signs shall have both bulbs working at all:'•times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at Lloo.r level.. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1.and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 4.1.3.2.1) 7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) N Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 :. '. %ist�� Jrri iti.:+ t': Sy7did:.: IMYr1? i 'R:trtifLtt�lS•LWW�ar.�ruriunwa trvtx!. City of Tukwila John W. Rants, Mayor Fire Department . Thomas P. Keefe, Fire Chief Page number 4 C er..: aYr+ h e.< a+ w.... wa ..H,w.,,.ara.ny..Ne«cnr���uwn ate.. w..tr.e..,wwi.r....�+.1.a 9. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more-than 50 heads shall have the written approval of the W.S."R:B'., Factory Mutual, Industrial Risk Insurers, Kemper. or any other representative designated and /or recognized by The City of Tukwila, prior to submittal the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test, Certificates submitted to The Tukwila Fire• Prevention'Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80), 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206)57$4404 • Fax (206) 5754439 Page number City of Tukwila Fire Department requirements based on type of construction, draft stop partitions and 'roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered,, breached, penetr removed improperly installed. (UFC 701) The maximur flame spread class of finish materials used on interior'walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) John W. Rants, Mayor Thomas P. Keefe, Are Chief Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 57.5-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone; (206) 5754404 • Pax• (206) 5754439 February 10, 1997 1- 9604- DBW97024 To: Subject: Larry Allen Leonard Astemborski Terry Beals Rick Ford Len Knecht N. Konwent John Murdoch N. Pestisme Lori Pitzer Mike Sullivan Gary Taller Rex Turner 1997 Washington State Contractor's License for The Boeing Company Enclosed is a copy of the Washington State Contractor's License for 1997. This license expires on January 1, 1998. Please contact me if you have any questions. �t f D. B. Weigelt 1 -9604, 1F-09 (206) 655 -4535 Enclosure 19 -35 OH -13 63 -04 2R -71 63 -04 5H -26 89 -14 63 -04 2R -71 3U -EH 46 -87 7R -35 ft HOE tNL-:294ML DEPARTMENT OF LABOR AND INDUSTRIES THIS .cERTIFIES THAT THE PBR§QN NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A STATE OF WASHINGTON F525 -052-000 (3.92) � SEPARATE PERMIT REQUIRED FOR: MECHANICAL `�4 ELECTRICAL 1` PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH SEATTLE, WASHINGTON 98108 VICINITY MAP 14_01 PROJECT SITE FROM SEATTLE— TACOMA AIRPORT FROM DOWNTOWN SEATTLE EAST MARGINAL WAY CORPORATE PARK 599 TUKWILA 900 DEVELOPMENTAL CENTER FROM KENT & AUBURN — EXIT NO SCALE ADDRESS: (EAST! MARGINAL WAY CORPORATE PARK) 3417 SO. 120TH PLACE SEATTLE, WA BUILDING 21 -04 (WAREHOUSE "B2" & "F SEE PLAN BELOW AREA MAP PROJECT SITE NO SCALE EAST MARGINAL WAY CORPORATE PARK ®_® REY15hN 11111111111.1111111111 • __11111111 _ - __- FACILITIES DEPARTMENT DRAWN RC CHECKED MGR. EC. APPROVED VP R6 ED GENERAL NOTES CONSTRUCTION, SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. VERIFY ALL DIMENSIONS PRIOR TO START OF CONSTRUCTION. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRED DESIGN REVISIONS. REVISIONS TO BE APPROVED BY CITY OF TUKWILA PRIOR TO PROCEEDING WITH PROPOSED REVISED WORK. RETURN THIS SAME SET TO GARY TAI-LER AT BUILDING 9 -51.2 COL N/1 AFTER COMPLETION OF THIS CONSTR.;CTION PROJECT CHECKLIST CHECK BOX ❑ THESE DRAWINGS CONFORM TO THE 1994 U.B.C., U.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH THE CITY OF TUKWILA ZONING. ❑ ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 —A. BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): 0 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION, SPECIFICATIONS IE 2. TENANT IMPROVEMENT (NON— STRUCTURAL): 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. TENANT IMPROVEMENTS (REVISIONS), 2 COMPLETE SETS ❑ 4. MECHANICAL, 4 COMPLETE SETS ❑ 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS ❑ BRIEF PROJECT NARRATIVE EXPAND THE MEN AND WOMEN TOILET AREAS Pq -0 116 SEA'' SHOP SHEET NO. Al 1A11R 1A11 A370 A501 M451 SHEET TITLE COVER SHEET, LEGALS & NOTES FLOOR PLAN (REMOVAL) FLOOR PLAN INTERIOR ELEVATIONS MISC. DETAILS EXHAUST FAN LAND USE CODE CODE REFERENCES OCCUPANCY GROUP OCCUPANCY CHANGE CONSTRUCTION TYPE AREA SEPARATION WALLS NOTE: 3 BLDG. 'PORTIONS LOCATION ON PROPERTY FLOOR AREA (ACTUAL) BUILDING HEIGHT: STORIES: REMODELED AREA: OCCUPANT LOAD: SWORE FILE COPY to rstand that the Plan Check approvals are to errors and orii scot and approval of I , .; dray not authorira sloe qulatign of any adopted code or ordine!s• e Receipt of Ton- i ctar'sco yof approved p - %tl! 4 By Dote Permit No. DRAWING INDEX REV. NO. SHEET NO. CODE SUMMARY ARCHITECTURAL MASTER SHEET TITLE M —HP 1994 UBC, KING COUNTY /TUKWILA WASHINGTON STATE ENERGY CODE WASHINGTON STATE BARRIER FREE CODE ADDITIONS TO THE CITY OF TUKWILLA B 2 STORAGE FOR COMBUSTIBLE GOODS 8 -2 OFFICE B -2 (WAREHOUSE — STORAGE OF GOODS TO F -2 FACTORY AND INDUSTRIAL LOW HAZARD AT NORTH PORTION ONLY — '(36,584 SF), V —N SPRINKLERED THROUGHOUT 2 HOUR + HORIZ. SEPARATION S THE ROOF ON LIEU OF PARAPET WALL) N. PORTION (BOX SHOP), CENTER & S. PORTIONS (NO CHANGE) SEPARATIONS —(3 SIDES) CO N. & S. PORTIONS AND (2 SIDES) 0 CENTER PORTION OF THE BUILDING. BUILDING FOOTPRINT = 113,724 S.F. 26' -5 1/2" FLOOR TO TOP PLATE 1 W/ 5,220sf MEZZANINE IN THE S. PORTION 36,594 sf CHANGES FROM B -2 TO F -2: [36,584 sf /200] — [36,584 sf /500] _ (193 — 73) = 110 WAREHOUSE = 44,080 C. PORTION + 30,740 S. PORTION W 500 = 150 STORAGE = 1550s1 S 300 = 5 MECHANICAL = 1,B50sf 49 300 = 7 MANUFACT = 36,584sf 10 200 = 183 for the N. PORTION OFFICE = 8,092sf 19 100 = 81 in the S, PORTION MEZC. CONFERENCE= 140sf 0 15 = 10 FIRE PROTECTION`' FULLY AUTOMATIC, WET PIPE THROUGHOUT SMOKE VENTS & TURTAIN BD. INSTALLED IN ENTIRE BUILDING IN 1993. SEISMIC ZONE 3 I I I to lI A FIRE ZONE 3 PARKING PROMO 739 PARKING REQUIRED 725 BLDG. 21 -04.1 COL. A--- K/1 -11 1 REV NO usr € spa. r£tc TITLE SHEET 9H D.C. SHEET NO. ADD NO. 160086 -00 DWD ND. 21 -04 —A1 All A501 TEMPERATURE HUMIDITY CWIMBER 32" 2" 32 ", BUCKETS 0008000 LYONS STORAG CABINETE S VIBRATION TABLE 17' -6" '1A11 A202 1A11 A501 NOM. 12" IA11 A202 PALLET RACK 44x14 PALLET RACK ALLET RACK 44X144 25 -6" HELD ORDER CHANGES - 7/18/97 *ADD \ ADD NEW SC WD. DOORS W/ H. MTL DJOR FRA ES REUSE EXIST'G UNICAN LOCK ON JANITORS CLOS T USE YALE AU5405LN -26D LOCKSET ON ACCESS DOOR. TO M /E. USE QUALITY PUSH AND PULL ON MEN'S AND WMEN'S TOILETS INSTALL S. STL KICKPLATES ON AHD TOILE ROOMS. PAINT DOOR AND FRAMES AS DIRECTED. REMOVE EXISTING WALL CONSTRUCT NEW WALL 6" EAST OF EXISTING 4 THIS IS DONE TO ALLOW FOR SAN. SE R CONN CTION FILL -IN EXISTING JAN. DOOR OPEN'G TE MATCH EXISTING WALL CONSTRUCTION A l TAPE SPACKLE AND PAINT BDC -1 '" I INSTALL A 24' WIDE X 42" HIGH PARTI ON 12' FFL AS A VISUAL BARRIER A INSTALL WALL FURRING AROUND FLOC. DRAIN I VENT PIPING. - SEE MECHANICAL I F INSTALL 34" X 8' HIGH STUD & GAB PAR PAINT TO MATCH EXISTING BDC -1. I LED) ALVAGED Z.. PAINT. MIXERS STORAGE AREA 1 101E5 ENCH zaxz INSTALL 3'x7' -7" SWING SHOP FENCE GATE W/12" WIDE SHOP FENCE PANELS AT EACH SIDE AS SHOWN. GATE TO HAVE UNICAN LOCKSET, BUTTONS ON PUSH SIDE, GATE WITH POSTS, 12 "WIDE BY 8' HIGH FENCE PANELS AND UNICAN SUPPLIED BY BOEING. ANCHOR POSTS W /MIN. 1/2 "0 BY 4 -1/2" (MN. 3 -1/2" EMBED) LONG HILTI KWIK POLES, USE 4 BOLTS AT ALL POST . AND ADJACENT TO FENCE OPENINGS AND 2 BOLTS AT INTERMEDIATE POSTS. (1YP, FASTENINGS) ALL PANELS, POSTS AND SWING GATES TO BE PAINTED PRESERVATIVE PAINT BDC1 COLOR. CONTACT GEORGETOWN PRESERVATIVE PAINT STORE FOR PAINT SUPPLIES. ' INSTALL NEW 8' CHAIN LINK, FENCING. POST TO BE ANCHORED TO CONCRETE FLOOR WITH BASE PLATES, SIMILAR TO SHOP FENCE. DO NOT CORE DRILL CONRETE FLOOR. DO NOT INSTALL BARBED WIRE ALONG TOP OF FENCE. SEE SHE 1A10 FOR CONTINUATION I 440.8E - COPIER C AIN LINK & SHOP FENCE ONLY FEO-T t1 t7c ( FIBERBOARD STORAGE FOAM STORAGE III PLAN SCALE 1/8" = 1'- 40 "0' HOLE THRU ROOF 36 "0 DUCT ABOVE BOOTH 36 "e DUCT FROM BOOTH FEO-I L } PA I SPRAY BOOTH (REASSE FROM 7- 00 t SEE SHT. 1A10 FOR CONTINUATION DRILL PRESS 0 FE I RACK S © INSTALL NEW 3'x8' SHOP FENCE SWING GATE. GATE TO HAVE INSTALLED HASP. SEE SHOP FENCE SKETCH FOR FENCE POST INSTALLATI AND ANCHORS. SUGGESTED SHOP FENCE PAN AND POSTS SUPPLIER: SECURITY FENCE CO. ATTN: TOM @ 838 -1351 APPROXIMATE SIZE', OF MOBILE OFFICE SPACE UNITS. 2'x8' SHOP FENCE PANEL. ALL PANELS, POSTS AND SWING GATES TO BE PAINTED PRESERVATIVE PAINT BDC1 COLOR. CONTACT GEORGETOWN PRESERVATIVE PAINT STORE FOR PAINT SUPPLIES, NOTE: CROSSED OUT ITEMS ARE TASKS THAT ARE SEPARATELY PERMITTED & ARE ON ANOTHER SET OF ARCHITECTURAL DRAWING. CITY OF TOKWIIA APPROVED JUL 3 0 1997 AS Oa BUILDING IV LEGEND: EXISTING WALL NEW WALL SYMBOLS HW TR w OPT o FD 0 FE SERVICE SINK HOT WATER TANK TRASH CAN(30 GAL) TRASH CAN W/ FIPPER TOP PAPER TOWEL DISPENSOR FLOOR DRAIN FIRE EXTINGUISHER SEE APPLICABLE INTERIOR ELEVATION ON SH A370 GENERAL NOTES: ASBESTOS NOTIFICATION: A good faith survey of the work area has been conducted and asbestos containing material was not doscovered that would be involved in the construction of this project. Do not remove, damoge or disturb any asbestos material adjacent to the work ore Please contact Boeing Facilities Department if asbestos containing material is damaged or discovered that is required to be removed to support work. CONSTRUCTION NOTES: INSTALL (6) PALLET RACKS (1 RELOCATED SEE 1A1OR) SEE STRUCTURAL DRAWINGS INSTALL (8) CANTILEVER RACKS SEE STRUCTURAL DRAWINGS, INSTALL 29LF, OF 24' -2 " +/- HIGH (TO BOT OF GL. BM.) SEE SECTION D ON SH A202 # L4- 676F- 8F- 19PT- HIGN-/JA6 b ARE-PrOVER -NE: W dAN-C -SEE- SECTION A ON DII. A501 & ® INSTALL NEW STRUCT, AND PATCH / PAINT WALL AS REQ'D. SEE SECTION F & G SH A202, INSTALL 3' X 7' HM. DOOR & FRAME ASSEMBLY. SEE DETAIL 2 SH, A200 INSTALL THE FOLLOWING HARDWARE: HINGES: STANLEY FBB175 412 X 412 26D LOCKSET: YALE 5407LN26DRH -LESS 1210 CYL. CLOSER: NORTON, 75008F INSTALL 3' X 7' HM, DOOR & FRAME ASSEMBLY - 2 HOUR RATED SEE DETAIL 1 SH, A200 INSTALL THE FOLLOWING HARDWARE: HINGES: STANLEY FBB179 412 X 412 26D PANIC BOLT: VON DUPRIN 99E0 US26D LEVER HANDLE: SIMPLEX LRP1020M -26D CLOSER: NORTON, 7500BF SMOKE SEAL: "PEMKO," FM TYPE 588017 gil›-INSTALL "SANYMETAL," OR-E TOILET PARTITIONS INSTALL (4) SALVAGED BOLLARDS SEE DETAIL 4 SH. A200 ® INSTALL (1) SALVAGED BOLLARD SEE DETAIL 3 SH. A200 ® REWORK EXISTING BOLLARD /RAII TO FIT RELOCATED CHARGERS - SEE SECTION D SH, A200 INSTALL (1) 1ABC, DRY CHEMICAL, 6 LB, (Al K 3A4OBC FIRE EXTINGUISHER. ( i 1 OP PAINT AS DIRECTED S POST 10" X 14" SIGN ® 8' FFL TO READ, "NO STORAGE ALLOWED ON ROOF," (2 REQUIRED) �:Gt7 <,6C't 4 : tl t °v' v�, IP,IjvI'Jt3Tf C,.L1 ILA( D.4YR._ASSEMBLIES ) pace t a7TY OF TUKW KEY PLAN PERA4 SCALE: N0' C N �rws CO REVISpN _ BY M. MILLER - APPROVED 841E 04.02.97 © BUSCH BY APPROVED BATE FACIL �0� IE3 DEPARTME AID ABI ;PECIFICATAN IS APPROVED L1PAM1i RY ED M. DI AR M1E 0 7 -2 J -96 r U(RI11E FLOOR PLAN S — 7� UST A(Ygq" I .S7P.AL W'T RELOCATE BOX SHOP J #160086 -00 �_� �� _ CREW B RELOCATE FINANCE PROP. MGMT. # 60241 -LO 1 HANSON APPROVED OEM u„E ENGR. ERE BLDG. 21- tJ4. ARCHITECTURAL MASTER COL. A- K/1 -3.5 D.C. C FENCE ADDITION REVISION TO 160086-00 HANSON 7.23.97 �"`C�" 160241 -0(7 D BATHROOM REVISIONS TO J#160086-00 M. M ILLER _ 7.23.97 APPROVED "" PPRtliED 21- 04 -1A1 All A501 TEMPERATURE HUMIDITY CWIMBER 32" 2" 32 ", BUCKETS 0008000 LYONS STORAG CABINETE S VIBRATION TABLE 17' -6" '1A11 A202 1A11 A501 NOM. 12" IA11 A202 PALLET RACK 44x14 PALLET RACK ALLET RACK 44X144 25 -6" HELD ORDER CHANGES - 7/18/97 *ADD \ ADD NEW SC WD. DOORS W/ H. MTL DJOR FRA ES REUSE EXIST'G UNICAN LOCK ON JANITORS CLOS T USE YALE AU5405LN -26D LOCKSET ON ACCESS DOOR. TO M /E. USE QUALITY PUSH AND PULL ON MEN'S AND WMEN'S TOILETS INSTALL S. STL KICKPLATES ON AHD TOILE ROOMS. PAINT DOOR AND FRAMES AS DIRECTED. REMOVE EXISTING WALL CONSTRUCT NEW WALL 6" EAST OF EXISTING 4 THIS IS DONE TO ALLOW FOR SAN. SE R CONN CTION FILL -IN EXISTING JAN. DOOR OPEN'G TE MATCH EXISTING WALL CONSTRUCTION A l TAPE SPACKLE AND PAINT BDC -1 '" I INSTALL A 24' WIDE X 42" HIGH PARTI ON 12' FFL AS A VISUAL BARRIER A INSTALL WALL FURRING AROUND FLOC. DRAIN I VENT PIPING. - SEE MECHANICAL I F INSTALL 34" X 8' HIGH STUD & GAB PAR PAINT TO MATCH EXISTING BDC -1. I LED) ALVAGED Z.. PAINT. MIXERS STORAGE AREA 1 101E5 ENCH zaxz INSTALL 3'x7' -7" SWING SHOP FENCE GATE W/12" WIDE SHOP FENCE PANELS AT EACH SIDE AS SHOWN. GATE TO HAVE UNICAN LOCKSET, BUTTONS ON PUSH SIDE, GATE WITH POSTS, 12 "WIDE BY 8' HIGH FENCE PANELS AND UNICAN SUPPLIED BY BOEING. ANCHOR POSTS W /MIN. 1/2 "0 BY 4 -1/2" (MN. 3 -1/2" EMBED) LONG HILTI KWIK POLES, USE 4 BOLTS AT ALL POST . AND ADJACENT TO FENCE OPENINGS AND 2 BOLTS AT INTERMEDIATE POSTS. (1YP, FASTENINGS) ALL PANELS, POSTS AND SWING GATES TO BE PAINTED PRESERVATIVE PAINT BDC1 COLOR. CONTACT GEORGETOWN PRESERVATIVE PAINT STORE FOR PAINT SUPPLIES. ' INSTALL NEW 8' CHAIN LINK, FENCING. POST TO BE ANCHORED TO CONCRETE FLOOR WITH BASE PLATES, SIMILAR TO SHOP FENCE. DO NOT CORE DRILL CONRETE FLOOR. DO NOT INSTALL BARBED WIRE ALONG TOP OF FENCE. SEE SHE 1A10 FOR CONTINUATION I 440.8E - COPIER C AIN LINK & SHOP FENCE ONLY FEO-T t1 t7c ( FIBERBOARD STORAGE FOAM STORAGE III PLAN SCALE 1/8" = 1'- 40 "0' HOLE THRU ROOF 36 "0 DUCT ABOVE BOOTH 36 "e DUCT FROM BOOTH FEO-I L } PA I SPRAY BOOTH (REASSE FROM 7- 00 t SEE SHT. 1A10 FOR CONTINUATION DRILL PRESS 0 FE I RACK S © INSTALL NEW 3'x8' SHOP FENCE SWING GATE. GATE TO HAVE INSTALLED HASP. SEE SHOP FENCE SKETCH FOR FENCE POST INSTALLATI AND ANCHORS. SUGGESTED SHOP FENCE PAN AND POSTS SUPPLIER: SECURITY FENCE CO. ATTN: TOM @ 838 -1351 APPROXIMATE SIZE', OF MOBILE OFFICE SPACE UNITS. 2'x8' SHOP FENCE PANEL. ALL PANELS, POSTS AND SWING GATES TO BE PAINTED PRESERVATIVE PAINT BDC1 COLOR. CONTACT GEORGETOWN PRESERVATIVE PAINT STORE FOR PAINT SUPPLIES, NOTE: CROSSED OUT ITEMS ARE TASKS THAT ARE SEPARATELY PERMITTED & ARE ON ANOTHER SET OF ARCHITECTURAL DRAWING. CITY OF TOKWIIA APPROVED JUL 3 0 1997 AS Oa BUILDING IV LEGEND: EXISTING WALL NEW WALL SYMBOLS HW TR w OPT o FD 0 FE SERVICE SINK HOT WATER TANK TRASH CAN(30 GAL) TRASH CAN W/ FIPPER TOP PAPER TOWEL DISPENSOR FLOOR DRAIN FIRE EXTINGUISHER SEE APPLICABLE INTERIOR ELEVATION ON SH A370 GENERAL NOTES: ASBESTOS NOTIFICATION: A good faith survey of the work area has been conducted and asbestos containing material was not doscovered that would be involved in the construction of this project. Do not remove, damoge or disturb any asbestos material adjacent to the work ore Please contact Boeing Facilities Department if asbestos containing material is damaged or discovered that is required to be removed to support work. CONSTRUCTION NOTES: INSTALL (6) PALLET RACKS (1 RELOCATED SEE 1A1OR) SEE STRUCTURAL DRAWINGS INSTALL (8) CANTILEVER RACKS SEE STRUCTURAL DRAWINGS, INSTALL 29LF, OF 24' -2 " +/- HIGH (TO BOT OF GL. BM.) SEE SECTION D ON SH A202 # L4- 676F- 8F- 19PT- HIGN-/JA6 b ARE-PrOVER -NE: W dAN-C -SEE- SECTION A ON DII. A501 & ® INSTALL NEW STRUCT, AND PATCH / PAINT WALL AS REQ'D. SEE SECTION F & G SH A202, INSTALL 3' X 7' HM. DOOR & FRAME ASSEMBLY. SEE DETAIL 2 SH, A200 INSTALL THE FOLLOWING HARDWARE: HINGES: STANLEY FBB175 412 X 412 26D LOCKSET: YALE 5407LN26DRH -LESS 1210 CYL. CLOSER: NORTON, 75008F INSTALL 3' X 7' HM, DOOR & FRAME ASSEMBLY - 2 HOUR RATED SEE DETAIL 1 SH, A200 INSTALL THE FOLLOWING HARDWARE: HINGES: STANLEY FBB179 412 X 412 26D PANIC BOLT: VON DUPRIN 99E0 US26D LEVER HANDLE: SIMPLEX LRP1020M -26D CLOSER: NORTON, 7500BF SMOKE SEAL: "PEMKO," FM TYPE 588017 gil›-INSTALL "SANYMETAL," OR-E TOILET PARTITIONS INSTALL (4) SALVAGED BOLLARDS SEE DETAIL 4 SH. A200 ® INSTALL (1) SALVAGED BOLLARD SEE DETAIL 3 SH. A200 ® REWORK EXISTING BOLLARD /RAII TO FIT RELOCATED CHARGERS - SEE SECTION D SH, A200 INSTALL (1) 1ABC, DRY CHEMICAL, 6 LB, (Al K 3A4OBC FIRE EXTINGUISHER. ( i 1 OP PAINT AS DIRECTED S POST 10" X 14" SIGN ® 8' FFL TO READ, "NO STORAGE ALLOWED ON ROOF," (2 REQUIRED) �:Gt7 <,6C't 4 : tl t °v' v�, IP,IjvI'Jt3Tf C,.L1 ILA( D.4YR._ASSEMBLIES ) pace t a7TY OF TUKW KEY PLAN PERA4 SCALE: N0' C N �rws CO ONSION RELOCATE BOX SHOP 4160086 -00 KIM 1A11 A20 IN M. MILLER 4 APPROVED DATE 0602.97 5 -7" e IN ROVED PLAN SCALE: 1/8" = 1 —0" STORAGE AREA I 101F2 I STORAGE AREA 101F5° FEO- B!®E/ierI7 FACILITIES DEPARTMENT G 1* _1l APPROVED IN AC D D I ON I P /OR SPECIflCATpH IS APPROVED DEPT. FEO- E3 DRAWN M. RIT TMAR CHECKED F1R:R CHECKED APPROVED APPROVED 7- 01-23-96 SURRDE LEGEND: TR ❑T 0 PT o FD 0 FE DF GENERAL NOTES: ASBESTOS NOTIFICATION: A good faith survey of the work area has been conducted and asbestos containing material was not doscovered thot would be involved in the construction of this project. Do not remove, damage or disturb any asbestos material adjacent to the work area. Please contact Boeing Facilities Department if asbestos containing material Is damaged or discovered that Is required to be removed to support work. SEE PRECEEDEING SHEET 1A1OR FOR CONSTRUCTION GENERAL NOTES! CONSTRUCTION NOTES: €M - GRIND - Matti - TWO DOLTS'FLUSII W/ CON2 SCE SECTION C SI A200 • REMOVE AND REINSTALL 4 DOLLARDS SCC GCCTION C SII. A200 -o- DISMANTLE AND SURPLUS 10 FINGER- RAGK-S-- ..� • ., -15- REMOVE AND REINSTALL 0 FINGER RACKS ® REMOVE AND SURPLUS (3) ELECTRIC BASEBOARD HEATERS REMOVE AND SURPLUS A DRINKING FOUNTAIN REMOVE AND REINSTALL A PORTABLE EYEWASH - -R €MOVE -AND REINSTALL A PAL LET -RAGH— ES- J REMOVE AND SURPLUS A SMALL HOT WATER TANK SEE MECHANICAL PLUMBING DRAWINGS REMOVE AND REINSTALL A SERVICE SINK SEE MECHANICAL PLUMBING DRAWINGS 'Cy REMOVE AND SAVE (3) WOOD DOOR /FRAME ASSYS. SAW ALSO ALL H SEE SH, All CCNST. PLANS. N OF A 21 1Rrr -5Ttle L SCE SECTION' .SH A202 !1; REMOVE (2) SECTIONS OF, STUD WALL 8' -1 "H X LENGTH SHOWN.ON P REMOVE (2) LAVATORIES AND SURPLUS REMOVE AND REINSTALL (1) TOILET COMPARTMENT REMOVE THE JANITORIAL EQUIPMENT & SAVE FOR REUSE 6) NONE KEY PLAN E; FLOOR PLAN (REMOVAL) BLDG. 21 -04.1 REMOVE WALL REMOVE OBJECT EXISTING WALL NEW WALL SERVICE SINK HOT WATER TANK TRASH CAN (30 GAL) TRASH CAN W/ FIPPER TOP PAPER TOWEL'DISPENSOR FLOOR DRAIN FIRE EXTINGUISHER DRINKING FOUNTAIN (A') "" RE' CEIVER PEPMn' CENTER ARCHITECTURAL MASTER COL. A- K/1 -3.5 D.0 J00 OWC ,3 v .,„... ,,,,,,.__....,,.,_ �o. Vhf KW. 1A11R 21- 04 -1A11R it NEW '' II I F LL II liai i T Iii rt t J L j � ,, it NEW '' II I F LL II liai i T - 5 PLAS. LAM. BACKSPLASH METAL PARTITIONS COAT HOOKS ON DOORS @ 48" P. LAM. T UP 4' -6" 6" R. BASE TYP G.W.B. (SWC.) METAL PARTITIONS NEW EXIST'G SERVICE SINK SEE MECH. DWG SCALE: 1/4" =1' -0" MIN. CRAB BAR REVISION SOAP DISP. @ 54" AFL 8' -10" (3)EQ. 24.7 "SPACES 16" N. WALL -MEN'S TOILET T SCALE: 1/4 "_= 1' -0" 1A11 1A370 6" H. RUBBER BASE TYP. ALL ARND. N. WALL- WOMEN'S TOILET SCALE: 1/4" = 1' -0" 1A450 1A370 17' - 0" NEW HOT WATER TANK - SEE MECHANICAL DRAWINGS 6" H. RUBBER BASE TYP. ALL ARND, N. WALL - JANITORS CLOSET �J SCALE: 1/4" = 1' -0" 1A11 1A370 SEAT COVER DISPENSER TOILET TISSUE DISPENSER SANITARY NAPKIN DISPOSAL (WOMEN ONLY) TOILET PARTITION (4) MIRRORS 24 "x36" TYP. G.W.B. (SWC.) TYPICAL TOILET COMPARTMENT SEAT COVER DISPENSER GRAB BAR TOILET TISSUE DISPENSER SANITARY NAPKIN DISPOSAL (WOMEN ONLY) TOILET PARTITION DATE HC SOAP DISP. AT 40" ABOVE FFL GWB (SWC. ) 7' FFL NOTE: INSULATE PIPES TO PREVENT BURNS DESK TELEPHONE OUTLET ELECTRICAL OUTLET 3' - 0" MIN. G.W.B. (SWC.) METAL TOILET PARTITIONS SEAT COVER DISPENSER SANITARY NAPKIN DISPENSER & DISPOSAL MOP BUCKETS TYPICAL HANDICAP TOILET COMPARTMENT SCALE: 1/4" =1' -0" —WASTE RECEPTICLE `O 6" H. RUBBER BASE TYP. ALL ARND. 6 H. RUBBER BASE TYP. GWB (SWC.) UP 7' FEL PLAS. LAM. BACKSPLASH SERVICE SINK SEE MECH. DWG. WASTE � EQ. �3)EQ. 24.7 "SPACES 16'' EQ RECEPTACLE SEE ALSO,ELEV.A - MEND TOILET PTD NOTE: INSULATE PIPES TO PREVENT BURNS E. WALL- WOMEN'S TOILET E S. WALL - WOMEN'S TOILET SCALE: 1/4 = 1 -0" 1A11 1A370 SCALE: 1/4" = 1'0 "' 1A11 1A370 W. WALL -JAN. CLOS. SCALE: 1/4" = 1' -0" 1 A11 1A370 E. WALL -MEN'S TOILET cy) SCALE: 1/4" = 1' -0" 170 5' -2" NOTE: PROVIDE SHEET METAL ` BACKING (SEE DETAIL 8/A200) FOR ALL SURFACE MOUNTED TOILET ACCESSORIES TYPICAL ALL TOILET ROOMS. DRINKING FOUNTAINS (DE) PAPER TOWEL DISPENSER (PTD) TYPICAL TOILET ROOM ACCESSORY MOUNTING HEIGHTS. SCALE: 1/4" 1 '-O" REVISION 3' -4" 1 2` -2" I !" U PAPER TOWEL DISPENSER ACCESSIBLE (PTD / HC) EXIST'G. MTL. PARTITION PL. LAM. WAINSCOT G.W.B. G.W.B. (SWC.) (SWC.) PROVIDE A SELF EDGED PLAS, LAM 16" DEEP SELF 6' LONG W/ A 4 "H PL,LAM BACKSPLASH @ 3 SIDES. (SWC.)= SPECIAL WALL COATING "DESCO - TEX" EPDXY - COTE. 3' -�' (BACK BAR MIN) SHEET' METAL rf" 1 ' ' BACKING TYPICAL ■ 1 • t . 3' -6" o (SIDE BAR MIN) N GRAB BAR FEM NAPKIN FEM NAPKIN DISPENSER DISPOSAL (FN) (END) APP DATE — REMOVE WALL iv LAVATORY AND REPLACE WITH A NEW URINAL G.W.B. FOR THE H.C. // ) REMOVE AND REPLACE SEE TYP TOILET EXISTING PLAS, LAM. COMPARTMENT DTL. WAINSCOTING BELOW S. WALL -MEN'S TOILET SCALE: 1/4" = 1' -0" 1A 1A370 6' - 5, 8' = 10" ■ EQ 4 1 NOTE: MAKE SINK SPACING ip SAME AS. IN MENS TOILET. 4'H RUBBER BASE S. WALL - PACKAGE TEST [L1" SCALE: 1/4" 1' -0" SHEET METAL BACKING TYPICAL- - TOILET PAPER DISPENSER (TPD) 8" SHELFf SHELF TOILET SEAT COVER DISPENSER (TSCD) VARIES SPAZEIAW FACILITIES DEPARTMENT 1A11 1A370 G.W.B (SAC.) (244)" MIRRORS x36" TYP. HC SOAP DISP. AT 40" ABOVE FFL PTD @ 40" PLAS. LAM. BACKSPLASH ON TWO SIDES SINK SALVAGED FROM 7 -81 -2 SOAP HCP DISPENSER SOAP (SD) DISPENSER (SD) REMOVE EXISTING WALL PATCH & PAINT TO MATCH PLAS. LAM. WAINSCOT SEE TYP TOILET 6 "H R. BASE SEE TYP TOILET COMPARTMENT DTL. COMPARTMENT DTL. BELOW BELOW LAVATORIES W. WALL -MEN'S TOILET /11 PARTIAL W. WALL -MEN' 1A11 1A370 SCALE 1/4" = 1' - 0" 1A11 1A370 SCALE 1/4" = 1' -0" METAL TOILET PARTITIONS W. WALL- WOMEN'S TOILET SCALE: 1/4" = 1' -0" 1 A11 1A370 PAPER TOWEL DISP. SOAP DISP, PAPER CUP DISP, EASED CTRTOP CORNER -SEE FLOOR PLAN PROVIDE (2) CYLINDER LOCKS 2' -0" 2' -0" 2' -0 W. WALL- ALCOVE SCALE: 1/4" = 1' -0" KNEE SPACE MIRRORS SOAP DISPENSER G p, 10' -8" SEE TYP TOILET COMPARTMENT DTL. BELOW KITCHENETTE D G.W.B. (SWC.) METAL TOILET PARTITIONS SCALE: NONE SCALE: NONE 170 D APPROVED G.W.B. (SWC.) PLAS. LAM. WAINSCOT T.P.D. SEAT COVER DISPENSER SANITARY NAPKIN DISPENSER & DISPOSAL NOTE: GOOSENECK FAUCET WITH WRIST BLADES MICROWAVE OVEN(2) ELECT, OUTLET(2) IN NORTH WALL PLASTIC LAMINATED COUNTER TOP EDGE & BACKSPLASH ELECT, OUTLET IN NORTH WALL REFRIG. NICHE 4 "R BASE ALL AROUND RECOMMENDED 1/32" RAISED TACTILE MOUNTING PICTOGRAM LOCATIONS —1/32" RAISED TACTILE LETTER (ALL CAPS) BRAILLE - GRADE 2 SIGNAGE — ELEVATION ACCEPTABILITY 1H5 DEIGN AND/OR SPECIflCAigN 5 APPROVED DEPT. O.W.B. (SWC.) PLAS.LAM, SELF EDGED CT'R -TOP, FRONT & BACKSPLASH DEMO M. DFT 1MAR CH APPROVED AP ENGR. M. MILLER CHECKED !ED REF.TO TRASH CAN 9 -28 -9 SOMME PTD SD ARCHITECTURAL MASTER LEGEND: INTERIOR ELEVATION GENERAL NOTES: BLDG. 21 -04.1 CONSTRUCTION NOTES: cm/REM/ILA AN 0 1 PERMIT CENTER A WALL /DUCT STRUC, FRAME ON PC PANELS 12,500 CFM l . SAW CUT A SQUARE Y HOLE 2' X 2' FOR A 22' ROUND DUCT SEE STRUCTURAL DRAWINGS. BOTTOM CURB EXIST'G PC, CONC TILT -UP EXTERI ❑R WALL. 4 X -12 X 3' -0" LONG W/ (4) 5/8'0 HILTI { -1Y {5o BOLTS X 4" EMBEDDMENT / X 12 DF #1 SIMPSON HU612 TF HANGER EXIST'G 2 X 4 STUD WALL 4 X 6 POST W/ SIMPSON ECC64 COLUMN CAP & POST. BC40 COL. BASE BELOW DETAIL BM. HANGER DETAIL BM. HANGER SCALE 1 1/2" = 1' -0" 1A11I A501 SCALE:_ 1 1/2" ?' -0" 1A11 A501 9' -0 NEW 11' -0" TYP, WALL: ' 5/8' GYP BD. EA. SIDE 1 X 4 WD STUDS @ 16 "oc, }� 2 X 6 WD STUDS @ JANIT ❑R HOUSEKEEPING 2 X 4 2 4'oc 2 X 4 ACROSS ROOM WOMEN ELECT, PANELS MEN EXIST'G SHT VINYL COVERED CONC. FLOORS EXIST'G CONE CURBS DECK OH DOOR 22'O DU T UP 19'- " f FFL TO 7' -6' R ROT❑ -CLONE TEN AY "FA DYNAMIC DUS PRECIPITATUR COLI CONC. OR AS PHAL RAMP — SE T S TRUC. NOTE: EQUIPMENT SHOWN IS FROM THE 7 -81 -2 BUILDING 5/8" FR TREATED PLYWOOD 2 X 6 DF JOISTS @ 12' ❑C SPRINKEL SPACE PER NFPA #13 2 X 4 @ 16" ❑C. 5/8" GYP BD. TYP, - 2 X 6 TRIM ARND, FFL CU REIGION RELOCATE BOX SHOP J #160086 -DO MRM AIM APPROVED PARTIAL EXTERIOR ELEV. SCALE: 1/8" = 1' -0" 5.16.9 10' — O" REMOVE EXIST'G CONE CU 101 FLEXIBLE CONNECTION Z - TYP. DAMPER EXISTING REMOVE EXISTING WALL REPLACE W/ NEW BEAM 6 X 12 DF #1 REY6D 6" THICK TILT -UP CONC. WALLS TYP, PARTIAL FLOOR PLAN 0 SCALE: 1/8" = 1' -0" 20' -6" 2' N. -S. SECTION THRU JAN. & TOILETS( SCALE: 3/8" =1' -0" REMOVE EXISTING WALL REPLACE W/ NEW BEAM 6 X 12 DF #1 1A11 A501 M. 10' -8 7/8" REMOVED JANITORS ROOM AND EXPANDED THE MEN'S TOILET - SEE PLAN SH 1A11 MAW FACICITIEE'' DEPARTMENT 2' r 8 1/2' EXISTING 2 HR. WALL CONT. TO ROOF DECK NEW WALL - 2 X 4 STUDS @ 16" oc W/ 5/8' GWB ON TOILET SIDE ACCEPTASITY iIYG D AND /DR SrEGE�ATnN a n.PaorEn APPROVED OV 22 GA. PARTIAL WALL WRAPPED WITH 5/8" TYPE -X GWB 1 1/2 "0 AL. HANDRAIL DRAM R S .RIVERA mmn ENGR CM APPROVED APPROVED Mrz 8 -20 -95 SECTION SCALE: 3/4" =1' -0" RUBBER BASE - 2 "x12" FIRE TREATED TREADS WITH MINIMUM 1/2" FIRE TREATED RISER BACKING PLYWOOD 6" 18 GA; MTL, JOISTS 16" O.C, SCREW JOIST TO STUD WITH 4 EA, SCREWS PER CONNECTION WITH 3/8" TYPE S -12 PAN HEAD SELF DRILLER SCREWS pq0i Ib ARCHITECTURAL MASTER RECEIVED CRY OF TUIKWIEA PERMIT CENTER i1