HomeMy WebLinkAboutPermit D97-0184 - MC LILE COMPANY - STORAGE RACKSCity of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 092304 -9066 Address: 3225 S 116 ST Suite No: 109 Location: Category: ACOM Type: DEVPERM Zoning: M1 KR314E SEC923 Const Type: RACKS Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: SEATTLE Sewer: VAL VUE Wetlands: Slopes: Y Contractor License No: EASYUSS08305 Permit Center Authorized Signature: Permit No: Status: Issued: Expires: (206) 431 -3670 D97 -0184 ISSUED 06/13/1997 12/10/1997 Occupancy: WAREHOUSE UBC: 1994 Fire Protection: SPRINKLERS /AFA East: .0 West: .0 OCCUPANT M.C. LILE COMPANY INC. 3225 S 116 ST,.TUKWILA, WA 98188 OWNER BEDFORD PROPERTIES INC 12720 - GATEWAY DR., SUITE 107, SEATTLE WA CONTACT CANDI KOHN Phone: 206.343 -0400 i741 FOURTH AVENUE SOUTH, SEATTLE, WA 98134 CONTRACTOR EASY UP STORAGE SYSTEMS Phone: 206 395 -2033 8731 S 212TH STREET, KENT, WA 98031 k** k************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL RACK SHELVING IN EXISTING WAREHOUSE. k**************************************** ************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: No: Size(in) .00 Flood : :Control Zone: Hauling: Start Time: End Time: Land Altering: Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start Time: End Time: Sanitary Side Sewer: No: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: Public: k***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** TOTAL DEVELOPMENT PERMIT FEES: $ 169.09 k***************************************** ********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 4 `a-— Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature:__ 44rVW Date: C Of'i'Q'l Print Name: LyilkiA I.QLS This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY. OF ' TUKWIL A. Addr.est •. 3225r S 116 = T Permit` No . ' 097 -0184: • Suite T enant Status.. °ISSUED Tvpe QEVPEhM, Applied• 06/.11 /1997 Parcel ?:# 11.92304 .9 Issued:; 06/13/1997 • A * .kk k-kkk* irk**'*• k'***: k* k' k k• k*' k****• k*'• k.***.*'.*. k***-hA*** * ** ****•k•k *'k * *•k•k. * * * *'kN *!y Permit: Conditions 1 No changes w ill: be. made to the ,plans unless approved bv the Architect `ar_Engineer� :and;.the Tukw.il „a Building Division. 2 A11 permits, ,irispe.ct d plans .shall b. • • av ailable: at:the j to the start': o,f. any con - .tr action The -er documents ;ar^e; to { =;be :maintained and avai 17. able”: until` finaljt.1 "ns ect.io approvat1 is granted All construction to {4 be `done ,tirroconfarmance . w10 approved plans and;ir eq'ii i r emetrts a" the Uhl form Building ode 1,994 Editi /as4amen,ded 4 a d i.t�f ,of Per mi i : 'Th'e sstrance of a permit or approval of O sifecif�'�cati,ons and comp,u'tations s hat l no;t he,::con 4L strue ? �i: o k be a permit fon o;r an ap.prava of any i!io;l,ation of at bf. ` of,the' building code or of :..ah o:ther�,or ~diva rce !of the, juris'dict.ion. No. perm.i 'Or esuming to giv = "authormtv ,v:iola or' a ncel., . t be provisi of th "is code shall ,be 'va l i d • Project Name/Tenant: 1 1\ . C . CI le. CoviNoav� Value of Construction: 5 C70a Site Address: City State/Zip: 32 So .11 ( St *- 109 ' C'cakwt (ac1 isk c.. S Tax Parcel Number: 09 2 ctocr,„=, Property Owner: D i vc o w'e.S Will there be rack storage? yes 171 no Phone: ao Ga ay 1 11 3 Street Address: 1 2, 4 Go C.,:. T_v>. -v* u� v l An- 'Sc City State /Zip: t_u T . u t, a g. ls 14.5( Fax #: a G t ► G Contractor: Ec s Li u_p 51fte-1 vtvt9 Phone: 3 5 c33 Street Address: City State /Zip: S 3 t SO , a caart te 9, g o 31 Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: itv State /Zip: 43 ( Fax #: Contact Person: CL �I le- cIrt .. Qtt LA/ VW\ Lois CO- Phone: aoca 3 3 0 L-loo Street Address: I Lt 1- t-1- v c Cc, City State/Zip: Ottla Q.e& t 3 y Fax #: 20 c. "34 3 acs S'-{ Description of work to be done: Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church gi Manufacturing ❑ Motel/Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail in Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church zi Manufacturing ❑ Motel/Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes no no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? yes 171 no vv fa Existing fire protection features: ,r1 sprinklers automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: `6300 C' IO existing Area of Construction: (sq. ft.) `"�► O Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 in the building? ,® yes ❑ no X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUW'VILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST. FOR PUBLIC WORKSSITE/CIVIL PLAN REVIEW OF THE:FOLLOWING:.., (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s) ❑ Water Meter Temp # Size(s): Est. quantity: 11 Miscellaneous ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: (n II Cr) Date application expires: i a I t -aj Application tgke y: (initials) PLEASE SIGN BACK OF APPLICATION FORM CI'PERMIT.DOC 1/29/97 BUILDING OWNS OR AUTHORIZED AGENT: 6, ,� Signature: �- Ve �� ,� G,�s � 0 •o (e e4, ON Phone: Zo I� - a le: Ca _ D3 - I I- 9 7 Fax tf:. 2VI 2i Print name: ,j04 Address SH ! 2 -�(QCti � h 4a , e S. I City /State /Z �, /� l k ALL COMMERCIAUMULTI -FA S V TENANT IMPROVEMENT /ALT TION PERMIT APPLICATIONS MUE SUBMITTED WITH THE FOLL • ING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER i> ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED U ❑ Complete Legal Description ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : I"J ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. Er �❑- Vicinity Map showing location of site ❑ lJ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. , Q X ❑ Indicate proposed construction of tenant space or addition and walls being demolished U ❑ Construction details • ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). • ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. IJ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ Er Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT ! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTI'I:RMJT.l)OC 1/29/97 ` � ` ` **°*+�v�+*++*^*���a+a� « ** NA ' ` TRANSMIT.' TRANSMIT.' : **a*-Pi*********14***ke «*� *���+^6�*m*a*hk**^+****+**+*+**+** **+ �" ��TQ ^ `' Number:`R97O0596'Amount: ' 169.O9 �6/11/97 1l:06: '" � Payment .��thod::.CHECK Notation: LYNN LuISEAU Init: SLB' Permit No: D97-0184 Type: DEVPERM ` DEVELOPMENT PERMIT Parcel No: 092304-9066 ` Site Address: 3223 S 116 ST Total Fees: 169.09 This Payment `. 169.09 � Total ALL Pmts 169.09 : Balance: .00 *****+***a*****+*+A****aah+**+a+aa«*******a******A+*+^**++*a***+ Account Code 000/322.100 000/345°830 000/386.904 - Description BUILDING - NONRES PLAN CHECK- NONRES STATE BUILDING SURCHARGE Amount 99.15 64"84 ' 4.50 1270 06/11 9705 TOTAL 169.09 Project:4f,-. """. i / -/ (..., . (p eZ.., Type of inspection no..? Address. 2. . Date called: Special instructions: . Date wanted: a.m. Requester: Phone No.: ••■•■■•■..11.00741.6414. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector [ I Approved per applicable codes. Receipt No.: ......6... INSPECTION RECORD Retain a copy with permit I I • '11 PERMIT NO. (206) 431-3670 Corrections required prior to approval. Date: $42.00 REINSPECTIcIN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: : �:' -'.. ia, o•, t::;. t. a.:.:..: rrwJ t.'`.xs�.,ts3 „,.un:.,:u. : 1.t.:1 aErwmito ix.co; ✓,3C?' :.u�£XF"Ar' PA ^ r WrIV AMYVVr VOhay:V1W:a 4s r:�s.:.xar.+ra riarr+:+xtt.�sn<new,�,. ii ?.°a „snr„ xtax:fitrcY., ACTIVITY NUMBER D97 -0184 PROJECT NAME DEPARTMENT: BUILDING DIVISION PUBLIC WORKS I I M.C. LILE COMPANY INC. FIRE PREVENTION C STRUCTURAL PLAN REVIEW / ROUTING SLIP DATE 6/11/97 PLANNING DIVISION El PERMIT COORDINATOR 0 I DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE C • NOT APPLICABLE C COMMENTS • TUES /TIJTJR.S ROUTING: PLEASE ROUTE C NO FURTHER REVIEW REQU ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL REVIEWERS INITIAL 1 APPROVALS OR CORRECTIONS: (ten days) APPROVED C APPROVED WI CONDITIONS L I CORRECTION DETERIVE NATION: APPROVED APPROVED WI CONDITIONS DATE t o I DUE DATE REVIEWERS INITIAL DATE 6/12/97 DUE DATE 6/26/97 NOT APPROVED (attach comments) 0 DATE 1 DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0184 PROJECT NAME M.C. LILE COMPANY INC. DEPARTMENT: BUILDING DIVISION PUBLIC WORKS DATE 6/11/97 FIRE PREVENTION ! PLANNING DIVISION Ell STRUCTURAL El PERMIT COORDINATOR El I DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE C1 COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL 4 �^'► .5 1 / NOT COMPLETE E] NOT APPLICABLE 0 DATE ? 2 I APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED WI CONDITIONS . NOT APPROVED (attach comments) Q REVIEWERS INITIAL t I CORRECTION DETERMINATION: APPROVED APPROVED WI CONDITIONS REVIEWERS INITIAL C:ROUTE -F DATE DATE DUE DATE 6/12/97 DUE DATE 6/26/97 DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) . . ..;r"z;ita "•�iJ'iics�; irOM 464 COMPLETE E COMMENTS APPROVED REVIEWERS INITIAL C:ROUTE -F ACTIVITY NUMBER D97 -0184 APPROVALS OR CORRECTIONS: (ten days) APPROVED I I APPROVED W/ CONDITIONS REVIEWERS INITIAL CORRECTION DETERMINATION: 16Vori: iLtste rth: f nV.m. t v'. CFYdN_^. ;':!A1YCd' R;tAl4 F.;4 4,'•7 PLAN REVIEW / ROUTING SLIP PROJECT NAME M.C. LILE COMPANY INC. DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION PLANNING DIVISION ■ PUBLIC WORKS fl STRUCTURAL D PERMIT COORDINATOR ❑ 4 DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE El • NOT APPLICABLE Er TUES /THURS ROUTING: PLEASE ROUTE a NO FURTHER REVIEW REQUIRED K ROUTED BY STAFF E] (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL A DATE G ' DATE APPROVED WI CONDITIONS p NOT APPROVED (attach comments) 0 DATE 's�7:AWT.xesa DUE DATE DATE 6/11/97 6/12/97 DUE DATE 6/26/97 NOT APPROVED (attach comments) C DUE DATE (Cerdficadou of occupancy required. ) rj s• PROJECT NAME PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0184 M.C. LILE COMPANY INC. DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION 1=1 PLANNING DMSION Q PUBLIC WORKS • STRUCTURAL PERMIT COORDINATOR 0 1 DETERMINATION OF COMPLETENESS: (T,Th) COMMENTS • REVIEWERS INITIAL CORRECTION DETERIVIINATION: REVIEWERS INITIAL C :ROUTE -F N .ffiSd�k'14CYXS$A'!t tr4.Ar.ourroup.'1`its utiN,,' M1+' fvia irvz.. mtropwkom!grmtiamacerouvs5frarg' o S R�] 7: fhMTnar. DATE DATE DUE DATE NOT COMPLETE El • NOT APPLICABLE n TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If route tall, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE 1 APPROVALS OR CORRECTIONS: (ten days) DUE DATE 6/26/97 APPROVED l l APPROVED W/ CONDITIONS NOT APPROVED (attach comments) 0 voreweremallil DUE DATE DATE 6/11/97 6/12/97 APPROVED 1 APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) 0 (Cerdficadoa of occupancy required. ) OPEN OFFICE OFFICE LUNCH :Pea OUT (e fA► Mile.) ,RstarooM'! 1.ut ) /z► lN(.i.uP•44 i 1 �6w/ a4dow4tzi ttfln %Pt 4 �--- r • a `, 9)bY ; K WIrN OAK.SAMe U414T - r161N1 SEAL, • vroP O tK'.�b ii' GNv{ 6G. OAK W/ OAK .1A41I51 , VAA• 44tll - (tom cc CD S c ati a • OFFICE 0\ \■ti0. 3 V.11 PEWIT CENTER 114 8I' X02 PA~w,tr. ri4m Floe La civet) vat1 r. i1t1(1111:111 {(( pin„ r�l'�, � t ;i:(1f n f){ Gat Vinttl g1 1. u•,t n ( 7 11r11 311111067,, tly■ • ( colln (;f 01(1111 :111 r:jlN PI ta 0' +.� 1 1 1 lIp ---- � 1� � -olv� 7, 1:, 11111 pl(1;:- - -...— RECEIVED CITY OF TUKWILA JUN 1 1 1997 r p11K M Intl oaf !% i4'Yi Gantt d..ccyV .1 g uflkt►DQ i1fiGleicA . TO 400A.4M MOv,! , Ll CONFERENCE A " fl4V VIA @ 5 ' o. 6. (2`404) -'•J OFFICE ✓r ItlY PROPOSED RACK SHELVING (See Attached Layout) M.C. Lile Company, Inc, 3225 South 116th Street, #109 Tukwila, WA 98168 SHELF # LENGTH DEPTH HEIGHT NOTES: 6'0" 1 "6 " .. 7'11 14'0" 2'0" 7'11" 4'0" 2'8" 7'11" 5 16'0" 1'0" 7'11" 6 1 22'0" Affixed to wall Aisle clearance = 6' Storage = cardboard boxes Affixed to wall Storage = paper Affixed to wall Storage = paper Affixed to wall Storage = cardboard boxes Affixed to wall Aisle clearance = 8' Storage = office records 1 . J 7'11" J Affixed to wall GM p R MOO E 0 Aisle clearance = 8' Storage = office records j u N i 2 5997 22'0" I 1'0" J 5'11"___I Storage = cans of ink_ .,._.. ---- -- BUILDlNG DIVISION L 8 j 30'0" 1 2'0" I 7'11" ] Affixed to wall Clearance to outside door = 6' Clearance to electric panel = 3'6" Storage = customer stock RECEIVED CITY OF TUKWILA JUN 101997 PERMIT CENTER JUN - 11 - 1997 13 47 J M.C.LILE CO. M.C. Lila Company, Inc. 3225 South 116 Street, Ste 109 Tukwila, WA 98168 HAZARDOUS MATERIAL PROPERTY QUANTITIES / STORAGE Blanket & Roller Wash Varnish Wash lammable Stored in 5 gallon metal container Maximum storage: two containers. Photo Fixer Waste Ink Waste Flammable Stored in 5 gallon metal container. Maximum storage: two containers. High silver content Waste is stored in 15 gallon container and picked up periodically by Safety- Kleen Corp. of Lynnwood. Maximum storage: one container Non - hazardous Waste is stored in 30 gallon container and picked up periodically by Safety- Kleen Corp. of Lynnwood. Maximum storage: one container RECEIVED CITY Off TUKWILA JUN 1 1 1997 PERMIT CENTER Safety - Kleen Corporation EPA #ILD984908202 6303 212 Street SW Lynnwood, WA 98036 M.C. Llle Company is considered by METRO to be a Small Quantity Generator of hazardous wastes. TOTAL P.02 Pax M;t coaro copy PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0184 PROJECT NAME M.C. LILE COMPANY INC. DEPARTMENT: BUILDING w� 1Q 1 9 i 1- 1 PUBLIC WORKS ❑ 1�1 I DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE p NOT COMPLETE p COMMENTS TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF p (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL t i APPROVALS OR CORRECTIONS: (ten days) APPROVED ❑ APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) p REVIEWERS INITIAL b i CORRECTION DETERMINATION: STRUCTURAL DATE DATE DATE 6/11/97 FIRE PI VENTION p PLANNIN IVISION El PERMIT COORDINATOR II DUE DATE 6/12/97 NOT APPLICABLE p DUE DATE 6/26/97 DUE DATE APPROVED I I APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) ❑ REVIEWERS INITIAL C:ROUTE -F DATE (Certification of occupancy required. ) • ., a. STATE OF WASHINGTON . . , . . . • .. . . . - • • , . , . , . . . , . . . , . . . , . . . . . • . . . . . . • - . . . , . . • . , „ . . . . . . , • , . . . . . . . . ., . . . . . . . . , . . . . . , . .. • . • , . , . r • a r , - 0141 t614,(1)644.) A iw mtg MO • Wilk (2 AK . _S AIP41 , T I614-11 GGA L , YV `� P rr br, . •Ai r, / 1rK.Ie° +b'I a OFFICE OPEN OFFICE LI" - * la R1.,4400pC w 24d 1.o'4, • 2V A AIF P( ' weft l too) •c� OFFICE_ 1 1 - I144TAL1. Y6h11 Fike4E0 GiAOR ni4.44- Pam nook g. (,3 wore,) 104144 C* (te / I G - up 1- or a r 4,-41, N/04). C� t Imo/ $'L[�'� { El 4,-0-H, t4 MCA DV 64-r iiLICA /— - ro 4449 A4474 2 42 V ° Sd'r - r (,Olr f frT CONFERENCE A"- FM' (11'0-1 S (71 ) -r l r(F OFFICE 2 0 i PROPOSED RACK SHELVING (See Attached Layout) M,C, Lile Company, Inc. 3225 South 176th Street, #709 Tukwila, WA 98168 SHELF # LENGTH DEPTH HEIGHT NOTES: 3 14'0' 4 6 7 8 6'0" I 1 "6" 14'0" 2'0" 4'0" 2'8'' 1'0" 22'0" 1'0" 22'0" 1'0" 30'0" j 2'0" 16'0" b II-- prut 2'0 r 7'11" 1 7'11" 1 Affixed to wall Aisle clearance = 6' Storage = cardboard boxes Affixed to wall Storage = paper 7'11" I Affixed to wall Storage = paper 7'11" 1 Affixed to wall Storage = cardboard boxes 7'11" 7'11" 5'11" 7'11" Affixed to wall Aisle clearance = 8' Storage = office records o i' (II i�` � Affixed to wall I\ F � ? Aisle clearance = 8' Storage = office records JO 1 - 1 917 Affixed to wall Clearance to outside door = 6' Clearance to electric panel = Storage = customer stock RECEIVED CITY OF TUKWILA JUN 1 0 1997 PERMIT CENTER Storage = cans of !ink r - -.