HomeMy WebLinkAboutPermit D97-0226 - SOUTHCENTER CORPORATE SQUARE - WALLS
City of Tukwila (
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
Parcel No: 262304 -9075
Address: 370 CORPORATE DR N
Suite No:
Location: BUILDING #10
Category: ACOM
Type: DEVPERM
Zoning:
Const Type:
Gas /Elec.:
Units: 001
Setbacks: North:
Water: N/A
Wetlands:
Contractor License No: - SGACO * *084BS.
Permit Center Authorized Signature:
Signa
WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES,
APPLICANT IS PROCEEDING AT THEIR OWN RISK.
.0 South: .0
Sewer: N/A
Slopes: N
_
DEVELOPMENT PERMIT
Print N
Permit No:
Status:
Issued:
Expires:
Streams:
(206) 431-3670
D97 -0226
ISSUED
07/18/1997
01/14/1998
Occupancy: OFFICE
UBC: 1994
Fire Protection: SPRINKLERED
East: .0 West: .0
OCCUPANT SOUTHCENTER CORPORATE SQUARE
370 CORPORATE DR N, TUKWILA WA 98188
OWNER SOUTHCENTER CORPORATE SQUARE Phone:.'. (206)575 -8500
C/O JSH PROPERTIES INC, 1005 ANDOVER PARK E, TUKWILA WA 98188
CONTACT RON GREENE Phone: 206 575 -2120
600 UNIVERSITY ST #2820, SEATTLE WA 98101
CONTRACTOR ' 'SGA CORPORATION Phone: 206 778 -2191
6414 204TH STREET S.W. #200, LYNNWOOD, WA 98036
k* ************ . **************************************** * * * * * * * * * * * * * * * * * * * * ** * * * * * * **
Permit Description:
REMOVE ALL NON BEARING WALLS.
******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Construction Valuation: $ 12,500.00
PUBLIC WORKS PERMITS: *(Water Meter Permits. Listed Separate) Eng. Appr:
Curb Cut /Access / /CSS:
Fire Loop Hydrant: No: Size(in): .00
Flood Control Zone:
Hauling: Start Time: End Time;
Land Altering: Cut: Fill
Landscape Irrigation:
Moving Oversized Load: Start Time: End Time:
Sanitary Side Sewer: No:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use:
Water Main Extension: Private: Public:
k**************************************************** * * * * * * * * * * * * * * * * * * * * * * ** * * * * * **
TOTAL DEVELOPMENT PERMIT FEES: $ 334.09
k**************************************************** * * * * * * * * * * * * * * * * * ** * * * * * * * * * * **
Date:
a - 1 � 9 L
I hereby certify that I have read and examined this permit and know the same
to be true and correct. All provisions of law and ordinances governing this
work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or
cancel the •rovision of any other state or local laws regulating construction
or the p• f•rmance of work. ,4I am authorized to sign for and obtain this
develo• ent permit.
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or abandoned
for a period of 180 days from the last inspection.
Address :
Tenant Status ISSUED
Type: DEVPERM Applied: 07/08/1997
Parcel '.#:1- , - , Issued: 07/18/1997
**** k k k* k*"*** k***' k k*; k** ** *,*, ** * * *;kh *-kk ** * *k, ** ** * * * *** * * *• ***
Permit ;Conditions.
1. No changes will be made to the plans unless : : approved by the
Architect or Engineer and th,e.Tukwila_Building Div,ision.
A1.:1 permits . inspection reccir:ds ' d' approve plans :shall .'be
a vailable a:t the aab set's prior, to the st'art. o:f any con
s•truction Thesedacuments are to`be maintain:e and avail -
:
able :unti 1 :f i,nalnspection approval is granted Y;
A1.1 const ru0 ; 71,0n o n
to be d m
'iri conforance with • ap'pro
plai and requ i s n' eme s at the Unifo Building ;, Code (1994
Ed tion) a mend edlr Uniform "`Mechan7`'c -a1 ,Code :01 Edition)
and Wasttiittgton State Ene' gv Code (1994 Edition).
Va l i d,i ty��o f:` t• a. The i ssuanoez ; ,of. a per ml or a;ppr.:ov
pl n
asy specificatz ancd. :computat,ions: shall not ,be con
struec to. b.e a: permit for� or an : approval, of any violat.i'
e any it-ha,' ' provisions of the building code :or : of an'y ;.
other7�, ordinance of - j tir isilict;i No permit `pr~esum {ng
give u ori ty.:'to uiala "te or,,,cancel the. provisions of ,t,hi.s
code�Y s tial l'' l i d ,•. , „ ,
t ✓
i�rs
I y
CITY OF TUKWILA
Project Name/Tenant: B i t *to
r -+ t -F f` PA 1 -.4' A c �c q :�'rSc..' - ��c"*.1 c'/..nl *E'
Value of Construction:
l 2 1500
-- Site Address: ('� City State/Zip:
.3( ) 0 r ...r. Pc) •.rr ■, k f' \ 1 l--- 1v �l 1 l . \ 0, \KA A-
1 /
Tax Parcel Number:
21,02-304--q 015 - --cC)
Property Owner: ` qe) \ Y� ,
‘- ,1 _ 1-;2_ V r•.!'' �n�,�3e — � Pl∎ \�;c1/' -�(lD -Af. r \e 's 1 LLL.
Phone:
Street Address: City State /Zip:
(on ° () ►,\ , \ 1.A/ 51.1 -L` `- s-e , A-__? RTrf) e, axi-± I e LO A-
Fax #:
I Area of Construction: (sq. ft.) �a a 0 co 0
Contractor: c\E \o
T. CD
Phone:
Street Address: City State/Zip:
Fax #:
• Architect: , r -
N$ 1
Phone:
22.3 —.5?-
t 'e--- \�0..Lc -I.(
Street Address: City State /Zip:
1 1 \ . c , .. 1(tc 1,e<z, (t-S ` 4 - i' e v . sec.1. E - t \ O - C- , VI \
Fax #:
6 'L- ti —2 -304
Engineer:
Phone:
Street Address: City State/Zip:
Fax #:
Contact Perso
Phone:
575-2. 1 ?JO
Street Address: City State /Zip:
T h V)tit 0(eArr, \ * 1 S -\,r _Q__; 7rX , `xk).tA -E- \.e (0 0- q R101
Fax #:
Si S i 1 9 g
Description of work to be done: Des,✓\ U u , ` _- s' \,,z
Existing use: El Retail El Restaurant El Multi - family C7,1 Warehouse ❑Hospital
El Church El Manufacturing ❑ Motel /Hotel a Office
❑ SchooVCollege /University El Other
Proposed use: El Retail ❑ Restaurant El Multi- family ❑ Warehouse ❑Hospital
❑ Church El Manufacturing ❑ Motel/Hotel %Office
❑ School /College /Universit 171 Other
it�
Will there be a change of use? ❑ yes l'L`Jt no
If yes, extent of change: (Attach additional sheet if necessary)
Will there be rack storage? ❑ yes Ea no
Existing fire protection features: ® sprinklers 211, automatic fire alarm El none El other (specify)
Building Square Feet: (DP CX00 existing
I Area of Construction: (sq. ft.) �a a 0 co 0
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes gg no
- Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets
CITY OF TUKWILA
Permit Center
6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188
(206) 431 -3670
Commercial / Multi - Family Tenant Improvement / Alteration Permit Application
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mall or facsimile.
APPLICANT REQUEST. FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW 'OFTHE FOLLOWING:
(Additional reviews may be • determined.by the Public Works Department)
El Channelization /Striping ❑ Curb cut/Access /Sidewalk
❑ Fire Loop /Hydrant (main to vault) #: Size(s):
El Land Altering 0 Cut cubic yds. 0 Fill cubic yds. El Landscape Irrigation
El Sanitary Side Sewer #: El Sewer Main Extension 0 Private 0 Public
El Storm Drainage El Street Use El Water Main Extension 0 Private 0 Public
❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only
El Water Meter /Permanent # Size(s):
❑ Water Meter Temp # Size(s): Est. quantity: gal
El Miscellaneous
❑ Flood Control Zone El Hauling
Schedule:
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and
is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by
the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
Date application accepted:
Dale application ex ires: -qR
Application taken by: (initials)
ICYP
PLEASE SIGN BACK OF APPLICATION FORM
CTPER/MMIT.DOC 1/29/97
BUILD WNER OR AUTH R/ZED AGENT:
Signal re:
-
Date: 7 /q /7, .7
Print na � `n
t vA v r c(CG
P hone : � 1S21 Z C)
Fax #: sr--15 t i i 8
Address
� /,C`c1
k � , .•t e- , re--E 2_R ? ?� , qS `O
k» x,11 � � -
City /State /Zip C
Seckr-t W P. cifi
ALL COMMERCIAUMULTI -FAIIL Y TENANT IMPROVEMENT /AL •ATION PERMIT APPLICATIONS
MUgT BE SUBMITTED WITH THE FOL • WING:
ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT,
STRUCTURAL ENGINEER OR CIVIL ENGINEER
▪ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ ❑ Complete Legal Description
❑ El Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Four (4) sets of working drawings (five(5) sets for structural work), which include :
❑ ❑ Site Plan (including existing fire hydrant location(s)
1. North arrow and scale
2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas
5. Recycle collection location and area calculations (change of use only)
6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of
use only)
9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of
those, identify by size and species which are to be removed and saved
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change
of use only)
11. Location and gross floor area of existing structure with dimensions and setback
12. Lowest finished floor elevation (if in flood control zone)
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H-
9).
❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled
❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of
any hazardous materials; dimensions of proposed tenant space.
El El Vicinity Map showing location of site
El ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of
rack. Structural calculations are required for rack storage eight feet and over.
❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished
❑ ❑ Construction details
El ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of
water supply to sprinkler vault with documentation from contractor stating supply line will meet or
exceed sprinkler system design criteria as identified by the Fire Department.
El El Washington State Non - Residential Energy Code Data shall be noted on the construction drawings.
❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds).
❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
land use or SEPA decisions.
El ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of
Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5)
❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no
contractor has been selected at time of application a copy of this license will be required before the
permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND ! AM AUTHORIZED TO APPLY FOR THIS PERMIT.
CTPI:RMIT.DOC 1 /29/97
01
' Account Code • 000/322.100
000/345.830
000/386.904
+����� ��+**�+******+
***+**+******+**** ** � * �n� a � *^°���
CITY OF TUKNILA, WA TRANSMIT
++*****+a***k*****+**+++k .****** k**k **7***. * ***icA**a**h*+*
TRANSMIT Number: R9700610 Amount: ' 334.09 Q7/08/97 14:23
Payment Method: CHECK Notation: LONE NW INVESTOR Init: KJP
Permit No D97-0226 Type: DEVPERM DEVELOPMENT PERMIT
Parcel No: 262304-9075
Site Address: 370 CORPORATE DR N
Total Fees: 334.09
This Payment 334.09 Total ALL Pmts: 334.09
Balance: .00
+*a*a******+*,■*4*********+***+++*+**a*a*A*****A****+*+**m**a**
Description
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
Amount
199.75
129.84
4.50
-`
Project:
at 4 d
Type of ' • -ction•
� / % — 7.1.4 0 ./
i /��
Address: ..
'
_
Date '- e d:
Date wanted:
/ .7-7 di:
Special instructions:
Requester:
Phone No.:
INSPEC 0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
I I
Approved per applicable codes.
COMMENTS:
Inspector:
INSPECTION RECOP''
Retain a copy with peLit
I I
Date:
P RMI O.
296) - 431
Corrections required prior to approval.
Q - ---
$42.00 REINSPECTII°!N FEE REQUIRED. Prior to inspection, fee rfiust
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
I Receipt No.:
Date:
Project:
'f�. '' JJ
Type of inspection ( ...00 0
Address: —
Date called:
Special instructions:
j3
0. • /0
Date wanted:
_2,1, 47
cit„. .
Requester:
Phone No.:
77 _ 2_1 1
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 j( (206) 431 -3670
1 Approved per applicable codes.
COMMENTS:
—] $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection,
Receipt No.:
INSPECTI RECO
Retain a copy with p
V7-0a-2,c,
PERMIT NO.
Corrections required prior to approval.
7 Date:
ACTIVITY NUMBER D97 -0226
PROJECT NAME
DEPARTMENT:
BRING DIVISION El FIRE PREVENTION El PLANNING DMSION fl
4 ,1(... WORKS L j PERMIT COORDINATOR II
to "17 O
DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 7/10/97
COMPLETE El
COMMENTS
TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED El
ROUTED BY STAFF E] (If routed by staff, make copy to master file & enter Sierra.)
REVIEWERS INITIAL DATE
I
APPROVALS OR CORRECTIONS: (ten days)
APPROVED El APPROVED W/ CONDITIONS [ NOT APPROVED (attach comments) Q
REVIEWERS INITIAL
CORRECTION DETERMINATION:
APPROVED [] APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0
REVIEWERS INITIAL
C:ROUTE -F
PQiyt* C.00r&fl Copy
PLAN REVIEW / ROUTING SLIP
SOUTHCENTER CORPORATE SQUARE BLDG 110
NOT COMPLETE El NOT APPLICABLE ❑
DATE
DATE
DATE
7
DUE DATE 7/24/97
DUE DATE
(Certification of occupancy required. )
t41?Rfst`;,'�Uw z. atS: *.' Spi +s? `:',Y'r�;:an?`' '•°:.1P1.@ n!'"+s =!«: i3Szr :agC4;g5;+� Mi;d:?`.�M :;25u
PLAN REVIEW / ROUTING SLIP
ACTIVITY NUMBER D97 -0226
PROJECT NAME SOUTHCENTER CORPORATE SQUARE BLDG 110
DEPARTMENT:
BUILDING DIVISION FIRE PREVENTION ❑ PLANNING DIVISION ❑
PUBLIC WORKS n STRUCTURAL ❑ PERMIT COORDINATOR ❑
I
J
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE
COMMENTS '
REVIEWERS INITIAL
NOT COMPLETE
TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED R
ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.)
I
I
APPROVALS OR CORRECTIONS: (ten days)
APPROVED C APPROVED W/ CONDITIONS Cl✓ NOT APPROVED (attach comments) 0
REVIEWERS INITIAL
REVIEWERS INITIAL
C:ROUTE -F
-,QL44
CORRECTION DETERMINATION:
DATE
DATE
DATE 7^ I0 -C17
1- O -T)
DATE
DUE DATE 7/10/97
NOT APPLICABLE ❑
DUE DATE 7/24/97
7/08/97
1
a
DUE DATE
APPROVED n APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑
(Certification of occupancy required. )
PROJECT NAME
REVIEWERS INITIAL
REVIEWERS INITIAL
APPROVED
REVIEWERS INITIAL
C:ROUTE -F
ACTIVITY NUMBER D97 -0226
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE n NOT COMPLETE
COMMENTS
APPROVALS OR CORRECTIONS: (ten days)
N
s
CORRECTION DETERMINATION:
APPROVED W/ CONDITIONS
T
PLAN REVIEW / ROUTING SLIP
SOUTRCENTER CORPORATE SQUARE BLDG 110
DATE
DEPARTMENT:
BUILDING DIVISION El FIRE PREVENTION 111 PLANNING DIVISION ❑
PUBLIC WORKS 0 STRUCTURAL n PERMIT COORDINATOR 0
I
DATE
DATE
DUE DATE 7/10/97
NOT APPLICABLE
TUES /TI-IURS ROUTING: PLEASE ROUTE C NO FURTHER REVIEW REQUIRED n
ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.)
APPROVED E APPROVED WI CONDITIONS E NOT APPROVED (attach comments) 11
DATE - 7'(0 - P 2
7/0 8/97
DUE DATE 7/24/97
DUE DATE
NOT APPROVED (attach comments) Q
(Certification of occupancy required.
V'
9
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE n NOT COMPLETE
COMMENTS
REVIEWERS INITIAL'
APPROVALS OR CORRECTIONS: (ten days)
REVIEWERS INITIAL
CORRECTION DETERMINATION:
APPROVED n APPROVED W/ CONDITIONS
C:ROUTE -F
i g'
':iiV .';ash ri4f+L: SAW. 'It,:e il:'• - 11 1 , 7,Y
PLAN REVIEW / ROUTING SLIP
ACTIVITY NUMBER D97 -0226 DATE 7/08/97
PROJECT NAME SOUTHCENTER CORPORATE SQUARE BLDG #10
DEPARTMENT:
BUILDING DIVISION El FIRE PREVENTION El PLANNING DIVISION
PUBLIC WORKS U STRUCTURAL ❑ PERMIT COORDINATOR Q
I
DATE -7//0/4'
DATE
REVIEWERS INITIAL DATE
DUE DATE 7/10/97
NOT APPLICABLE Ian
TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED K,
ROUTED BY STAFF Cn (If routed by staff, make copy to master file & enter Sierra.)
I
DUE DATE 7/24/97
APPROVED f n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) 0
DUE DATE
NOT APPROVED (attach comments) 0
(Certi1 cation of occupancy required. )
:L'!: sv ,'.'� 7ri'Sl,_ rNFf,4"s,. s` 4' eir!!?*+,.+,�,w:`.'
. 4 i.sur,'Si,..).W,tt'S,a,:s.
aiT;. d1} Si14i? r. 'ifi"i'S5�1 ?s7t: {•K.'cf'Sr:'wG'.{
ACTIVITY NUMBER D97 -0226
PROJECT NAME SOUTHCENTER CORPORATE SQUARE BLDG #10
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE NOT COMPLETE ❑
COMMENTS
APPROVALS OR CORRECTIONS: (ten days)
APPROVED n APPROVED WI CONDITIONS
REVIEWERS INITIAL
CORRECTION DETERMINATION:
APPROVED ❑ APPROVED WI CONDITIONS
REVIEWERS INITIAL
C:ROUTE -F
N
ickp hnarnami'.7. .n.:• :k . rivy, GS4 : tmg., * it;..C rxcThTug.4vorwmktyptil l°a atpsx : —
PLAN REVIEW / ROUTING SLIP
DATE
DATE
DATE
NOT APPLICABLE ❑
7/0 8/97
DEPARTMENT:
BUILDING DIVISION ❑, FIRE PREVENTION
PUBLIC WORKS ■ STRUCTURAL ❑ PERMIT COORDINATOR ❑
PLANNING DIVISION ❑
1
I
DUE DATE 7/10/97
TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRE
ROUTED BY STAFF ❑ ' - •• ff, make copy to master file & enter Sierra.)
REVIEWERS ' DATE 7 /0/
DUE DATE 7/24/97•
NOT APPROVED (attach comments) ❑
DUE DATE
NOT APPROVED (attach comments) ❑❑
(Certification of occupancy required. )
City of Tukwila
July /0 /997
Fire Department Thomas P. Keefe, Fire Chief
Fire Department Review .
Control # Oq2 •od-aSP
Re: T. I . at Soci'Fx:erl fe/Cor u c{Q /-t IC)
Dear Sir: Noe CorpOraff Di Ai
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3 -1.1)
Extinguishers shall be installed on the hangers or in
the brackets supplied, mounted in cabinets, or set on
shelves (NFPA 10, 1 -6.9), and shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor. (NFPA 10, 1 -6.9)
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher ", with an arrow pointing to the unit.
(NFPA 10, 1-6.3) (UFC Standard 10 -1)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1 -6.5)
Fire extinguishers require monthly and yearly
inspections. They must have a tag or label securely
attached that indicates the month and year that the
inspection was performed and shall identify the
company or person performing the service. (NFPA 10,
4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and
John W Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439
City of f Tukwila
Fire Department
Page number 2
Thomas P. Keefe, Fire Chief
halon type fire extinguishers shall be emptied and
subjected to the applicable recharge procedures. (NFPA
10, 4 -4.1) If the required monthly and yearly
inspections of the fire extinguisher(s) are not
accomplished or the inspection tag is not completed, a
reputable fire extinguisher service company will be
required to conduct these required surveys. (NFPA
10A -4 -4)
Maintain fire extinguisher coverage throughout.
2. No point in an unsprinklered building may be more than
150 feet from an exit, measured along the path of travel.
(UBC 1003.4)
No point in a sprinklered building may be more than
200 feet from an exit, measured along the path of
travel. (UBC 1003.4)
Exit doors shall swing in the direction of exit travel
when serving any hazardous area or when serving an
occupant load of 50 or more. (UBC 1004.2)
3. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 1207.3)
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space.
4. When two or more exits from a story are required, exit
signs shall be installed at the required exits and where
otherwise necessary to clearly indicate the direction of
egress. (UBC 1013.1)
When two or more exits from a story are required and
when two or more exits from a room or an area are
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439
1
__________-_.
City of Tukwila
Page number
Fire Department Thomas P. Keefe, Fire Chtef
required by U.B.C. Section 3303, exit signs shall be
illuminated. (UBC 1013.3)
Internally illuminated exit signs shall have both
bulbs working at all times. (UBC 1013.3)
5. Exits shall be illuminated any time the building is
occupied with light having an intensity of not less than 1
foot candle at floor level. Fixtures required for exit
illumination shall be supplied from separate sources of
power for Group I, Divisions 1.1 and 1.2 occupancies and
for all other occupancies where the exiting system serves
an occupant load of 100 or more. (UBC 1012.1,••1012.2)
The power supply for the exit pathway illumination
shall normally be provided by the premise's wiring
system. In the event of its failure, illumination
shall be automatically provided from an emergency
system. Emergency system shall be supplied from
storage batteries or an on -site generator set and the
system shall be installed in accordance with the
requirements of the Electrical Code. (UBC 1012.2)
6. Maintain sprinkler coverage per N.F.P.A. 13.
Addition /relocation of walls, closets or partitions may
require relocating and /or adding sprinkler heads.
Sprinkler protection shall be extended to all areas
where required, including all enclosed areas, below
obstructions and under overhangs greater than four
feet wide. (NFPA 13 -4- 4.1.3.2.1)
7. Maintain hose station coverage per City Ordinance
#1742 and N.F.P.A. 14. Addition /relocation of walls or
partitions may require relocating and /or adding hose
stations.
8. An approved hose station requires plans review.
(Plans must be submitted to the Fire Marshal for approval
prior to installation.) (City Ordinance #1742)
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439
City of Tukwila
Fire Department Thomas P. Keefe, Fire Chief
Page number 4
9. All new sprinkler systems and all modifications to
existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or
modification. New sprinkler systems and all modifications
to sprinkler systems involving more than 50 heads shall
have the written approval of the W.S.R.B., Factory Mutual,
Industrial Risk Insurers, Kemper or any other
representative designated and /or recognized by The City of
Tukwila, prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved
drawings. (City Ordinance #1742)
All sprinkler system plans, calculations and the
contractors Materials and Test Certificates submitted
to The Tukwila Fire Prevention Bureau must be stamped
with the appropriate level of competency seal. (WAC
212 -80)
10. Maintain automatic fire detector coverage per
N.F.P.A. 72. Addition /relocation of walls, closets or
partitions may require relocating and /or adding automatic
fire detectors.
Maintain square foot coverage of detectors per
manufacturer's specifications in all areas including:
closets, elevator shafts, top of stairwells, etc.
(NFPA 72, 5- 1.3.4)
11. All new fire alarm systems or modifications to
existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence
until a fire department permit has been obtained. (City
Ordinance #1742) (UFC 1001.3)
12. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
13. Required .fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439
City of Tukwila
Page number 5
Fire Department
requirements based on type of construction, draft stop
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall be
properly repaired, restored or replaced when damaged,
altered, breached, penetrated, removed or improperly
installed. (UFC 701)
The maximum flame spread class of finish materials
used on interior walls and ceilings shall not exceed
that set forth in Table No. 8 -B of The Uniform
Building Code. (UBC 804.1)
14. Your street address must be conspicuously posted on
the building and shall be plainly visible and legible from
the street. Numbers shall contrast with their background.
(UFC 901.4.4)
In order to provide you with the fastest police and
fire protection under emergency conditions, please
post your suite, room or apartment number in a
conspicuous place near the main entry door. Numbers
shall contrast with their background. (UFC 901.4.4)
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Contact The Tukwila Fire Prevention Bureau to witness all
required inspections and tests. (UFC 10.503) (City
Ordinance #1742)
This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439
The :Tukwila Fire Prevention Bureau
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575.4439
•!' -`,;•
Mitt 9.7" ...V.: 1 ;1 1 MVP.rf 1 7. 9) . 13 M2
DEPARTMENT OF LABOR AND INDUSTRIES
.••• , "••••'
STATE OF WASHINGTON
DETACH TO DISPLAY CERTIFICATE_I
..•
• •
• • . • •
Project Contacts:
Ric Anderson
Vice President
Lowe Enterprises Northwest, Inc.
One Union Square
20
600 university Street, Suite coca
Seattle, WA 98101
Phone: (206)623 -0200 Fax (206)623 -0600
Ron M. Greene
Chief Engineer
Lowe Enterprises Northwest Inc.
Phone: (206)575 -2120 l=ax (206)575 -1198
Shown Piclkerill
Project Manager
NBBJ
111 South Jackson Street
Seattle, Wa 98104
Phone: (206)223 -5555 Fax (206)621 -2301
ee11•1•■
Agency Notes
Addresx 555 ANDOVER PARK WEST
TUCKWILA, WASHINGTON
Building Code: 1994 U.B.C.
Construction: 5N
Fire Protection: SPRINKLER
Project Location: 2ND FLOOR
Occupancy. B
Legal Description
Al that certain red property situated in the City of Tukwla, County of 11bg
State of ington, being a of the east 1/2 of the northwest 1 4 of the
southeast 1/4 of Sec. 26 T.22N, RAE. W.Y., and Frelg more particukriy
described as follows
BEGINNING at the intersection of the n line of sold 1/4 with
the westerly margn of Andover Park West ( Avenue South), distant dung said
northerly line WM 1 1369.34 feet from the northwest coma of said south—
east qu e; thence Pram said POINT OF BEGINNING land said westerly margin
S014T2 451.30 �tthence leaving said westerly margin tangent to the
y
pr course arc of a save to the t having a radius of 50.00
feet and a central mole of 90'06'49', an arc length of 78.64 feet to a point on
a line that is parallel lo and 501.40 southerly of the nart fine of
said southeast 1/4; thence d odd parallel he N88135 4211 100.90 feet to
a point m a.lne at is pad with and 261.00 feet weetal of th east
line.If sold eat 1 thence clang lost sad pordd Ilse N01'4T29 'E 138.00
feet to o Ppoant an a line that io pordid to and 365.40 feet southerly of the
northerly of said southeast 1/4; thence ding last said parallel One
S88'05 42"tE 37.50 feet to a point m a line that ie padd p to and 223.50 feet
weste yyY the east the of said east 1 thence ding last said parallel line
N0147"29 4 _ 100.00 feet to a point on a One that js parallel to and 265.40 feet
southerly of the northerly line of said southeast 1/4; thence long last said
pordid line 68819542 12.50 feet to a pond on a line that is parallel to
and 236.00 feet westerly �E f the east line of said east 1/2; thence dang last
said pardld Ina 4 265.40 feet to a paint an the q nearly line of
said southeast 144 thence long said northerly lire S8805421 20&00 feet to
the POINT OF BE GINNING and containing 2,408 saes of land more or less.
1
CORPORATE y
'OR. N.
1.
CORPORATE (q-
pa S 5 MINK
!D ' MIDLAND DR
TRILAND DR.
fa BEta
VICINITY MAP
N.T.S.
NBBJ
111 South Jackson Street
Seattle, Washington 98104
(206) 223 -5555
Fax (206) 621 -2300
SOUTHCENTER
CORPORATE SQUARE
TUKWILA. WA
RECEIVED
CITY OF TUKWILA
JUL 6 8 1997
PERMIT CENTER
oq- , -oaatD
2 1/4' 3' -11 12'
32' -2 1/4'
78 -6 1/2.
7
EL
0
38' - o 3/4'
BLDG. 10 SECOND FLOOR DEMO PLAN A N
SCALE: I /8" - 1' -0"
1/2
2 1/4
21/4' 43. -11 1 2'
32' -2j/4'
0 BLDG. 10 FIRST FLOOR DEMO PLAN
SCALE: 1/8" = 1 -0"
38' -0 3/4:
78 1/2'
-I
3' -11 1/8
2 1/4'
rt
DEMOLITION PLAN NOTES
1. OBTAIN DEMOUTION PERMITS AND INCLUDE ALL COSTS
OF SAME IN CONTRACT PRICE
2. FURNISH All LABOR AND MATENNALS/EOUIPMENT TO 224212IE
DEMOURON AND REMOVAL OF ALL ITEMS AS INDICATED.
3. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND
DEBRIS FOR THE URA. OF CONSTRUCTION.
4. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL,
CLARIFY THE POINT IN QUESTION MTH THE ARCHITECT BEFORE
PROCEEDING.
5. AT COTLPLE3ON OF DEMOUTION WORK THE CONSTRUCTION AREAS)
SHALL BE LEFT IN 'BROOM CLEAN' CONDITION. ALL DEBRIS AND
MISCELLANEOUS MATERIAL SHALL BE REMOVED.
6. ALL DEBRIS REMOVAL SHALL DE PERFORMED IN ACCGRDANCE WITH
BUILDING MANAGEMENT REQUIREMENTS AND PROCEDURES AND
SHALL LEGALLY DISPOSED OF OFF SITE
7. AS DIRECTED BY BUILDING MANAGEMENT, ALL Dom-, FRAMES,
HARDWARE, MECHANICAL ITEMS, PLUNGING FIXTURES, UGHT FIXTURES
(INCLUDING 001MUCHT5 AND FLUORESCENTS), AND SPECIAL
EQUIPMENT SIROAN TO BE REMOVED, 9RALL BE CLEAN AND FREE OF
DEFECTS PROTECTED, SAVED AND REUS'c0 AS OiREC7ED HINEM,
RETURNED TO BUILDING STOCK.
8. IN PAR32ONS TO BE REMOVED, REMOVE AND CAP ALL OUTIE15,
SWITCHES, VANES, 1HERMOS1215, ETC. TO TH22 SOURCE.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND /OR REPAIRING
ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS TO EXISTING
CONSTRUCTION IN ELEVATOR LOBBY AND RESTROOMS,
:JNISI TO MATCH METING ADJAUNT
FINISH, CR AS NOTED HEREIN.
10. NO EXISTING 9101E DETECTOR, PUBLIC ADDRE2° SPEAKER, FIRE
ALARM BOX OR SIMILAR DENIM, INCLUDING THE ASSOCIATED WING
WALL BE DAMAGED DURING DEMOLITION AND SUBSEQUENT
CONSTRUCTION. RELOCATION OF 910E DETECTORS, PUBLIC ADDRESS
SPEAKERS AND FIRE ALARM EQUIP, T, NECESSITATED BY NEW
CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST HAMMY, AND
PER THE PLANS NO ACTIVE SMOKE DETECTOR 91AI BE COVERED OR
DRUMM REMOVED OR USED FOR OTHER THAN ITS INTENDED
PURPOSE.
11. EXISTING CEILING MIS IN AREA OF 4 SMALL RER ALL
AN U.O.N. A
WMCEN, PARTIAL, STAINED, OR DAMAGED 222 TILES SHALL LE
DISCARDED AND REPLACED MTH NEW TO MATCH EXSTING.
12. EXISTING CRUNC GRID TO REMAIN EXCEPT WHERE DAMAGE OCCURS
DUE TO DEMOUTION. REPLACE GRID IN AREA OF MOUTON TO
MATCH EXISTING.
13. REMOVE ALL PIPES, VENTS, APPLIANCES OR DRAINS IN WAY OF NEW
PARTITIONS.
RE -USE OR PELOCATE ALL ABOVE CEILING DUCTWORK DIFFUSERS,
GRILLES, SPRINKLER PIPES OR OTHER EQUIPMENT, AS REQUIRED FOR
PROPER DISTRIBUTION WITH NEW LAYOUT.
15. REMOVAL OF AN8 EQUIPMENT, CABUNG SNITCHES, AND CONDUIT
PERTNNING 10 DATA /COI/NUMCR3OSS AND TELEPHONE SMALL BE
VERIFIED WITH TELEPHONE COMPANIES AND TENANT.
16. REMOVE ALL EXISTING MATERIALS WHICH WOULD CAUSE RISES OR
DEPRESSIONS M NEW FLOORING SURFACE, SUCH AS FASTENERS,
OUTLET CORES, CO. PLATES, RESILIENT FLOOR COVERINGS,
CARPET, CARPET PAD, FLASH PATCH, CONCRETE FIE, PLYWOOD, ETC.
17. CAREFULLY REMOVE ALL E%ISTING WALL COVERING AT EASTING
24333
PARTITION$ LOW PARTITIONS AND COLUMNS NOT TO BE DEMOUSHED.
18. DEMOLITION IS NOT NECESSARILY UNITED TO WHAT IS SHORN ON
ORAINNGS THE INTENT IS TO INDICATE THE GENERAL SCOPE OF
DEMOUEON REQUIRED TO COMPLETE THE WORK IN ACCORDANCE YAW
THE CONTRACT DRAWINGS.
DEMDLmON KEY
PARTITION TO REMAIN
PARTITION TO REMOVE
I un_ :.. .'..t the Plan Chen'.
_. - -.., crrom and omissions cr.,
pi,8 cc es not authol M NAB 4Oletion 2N 7
Code Q COMM ItIO.O of Confraclo024
Y • 403234 ed gym.
FILE COPY
CITY OF TUh'V'IILA
APPROVED
JUL 15 1997
PERMIT CENTER
NBBJ
111 South Jackson Street
Seattle, Washington 98104
(206) 223 -5555
Fax (206) 621 -2300
B;.vD n. snrav I
LOUIE ENTIRPRJS
NORTHWEST. INC.
u
SOUTRCENTER
CORPORATE SQUARE
TUKWILA. WA
Sheet Ilse
BLDG. TEN
DEMOLITION PLAN
same 1/8' = 1' -0'
ov Da.a MLR
Bale 6-90-97 Checked
App,o,N By Jab kamEa 10951E5
Aee1 Number
RECEIVED T e ( ' \ � 1.0
CITY OF TUKWILA
JUL 081997
DT/ -oaa)(6)