Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D97-0280 - ENTERPRISE INSALLATION - STORAGE RACKS
City of Tukwila {- Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Print Name: //5,,e/2 Parcel No: 261320 -0084 Address: 4459 S 134 PL Suite No: Location: Category: AWSE Type: DEVPERM Zoning: ml Const Type: RACKS Gas /Elec.: Units: 001 Setbacks: North: Water: 125 Wetlands: DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK, Permit Center Authorized•.Signature'_ Permit No: Status: Issued: Expires: Occupancy: UBC:. Protection: .0 West: D97 -0280 ISSUED 09/19/1997 • 03/18/1998 WAREHOUSE. 1994 SPRINKLERS .0 Contractor License No:' OCCUPANT ENTERPRISE INSTALLATION INC 4459 135 PL, .TUKWILA,WA. 98168 OWNER PACIFIC ,CITIES INC: 3150 RICHARDS RD, BELLEVUE WA 980054446, CONTACT TERRY BENNETT Phone: 20 -2668 4459 S 134 PL, TUKWILA WA 98188 k• k****** ** **** **** ** ** ** ** ** ***** ** *•k* **** ** * **** * * *** ** k* *** * * ** ** ** *** **** ** *fir * *** Permit Description: INSTALL;, USED PALLET RACKS (15 SECTIONS) k***************************************************** * * * ** * * * * * * * * * * * * * * * * * * * * * * * Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water. Meter Permits Listed Separate) Eng Appr: Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: No Size(in) .00 Flood Control`. Zone: Hauling: Start Times': End•Time: Land Altering: Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start Time End Time: Sanitary Side Sewer: No Sewer Main Extension: Private: *Storm Drainage: Street Use: Water Main Extension: Private: Public: ********************'********************** k.************** * * * * * * * * * ** ** * * * *'k *k** * * * * * TOTAL DEVELOPMENT PERMIT FEES: $ _ 127.84 k************************************************** k* * * * * * * * * * * * * * * * * * * * * * *k* * * * * *** Publ i;c: SL Date: I hereby certify that I have read and .examined 'this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or riot. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature: Date: 97/9 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. (206) 431 -3670 Hq.ar es,s 4,4�`l >a ,1 54':= 'L F 'iY uy/ uGtsu :Suite Tenant Status. ISSUED • i7EVPERM A 08/2511997:. Parcel ` #, x.,61320 0084 Issued 09/19/1997 .***. ******k k4** kk* 4 * ** * *k' * *kk*.* * *. *:•k **k*kk *; Permit Conditions 1 No: changes, wil ., be :made ,.ta;. the p::l,ans `'unless ; approved `by .the z Ar chit`ect or Engineer and tfle r Tukw� la Buy l ding Divisi 2 A1.1 permits, ,inspe;c:tion, records, °and x a "ppr owed pla ns sh be. available at th:e fob site pr iar~ :ta 0;0 7- any ca struc,t;ion. These documents ar k: for be ma inta`t:ned nd "avail = able until ins ection - app grant eii`- ;,a;:` • All constru tiara to be Tian . n cor for.manc'e; With a''ppr+ove pla ns : and req irement —of the Uni,fn,rni' Bu;7ding.. ,a de�t1994 Edition) a,s amended, z>Uni fie chan,i.c Code (1994 Editoan >', and Was hing on 'at to Ener Code h (1 994 Ed`itionk` { ' 4 Va i d i. tyHof. Permit . The i ss`uance of a '.permit: g ar aappt oval of plans ,�l and °'comp . shall not :be can *� ' strue i;to be a :pe,r nrit for, °-o,r an' approval of,; any': violation r of° a N y of heS provisions of ` the building ' :code ot'he'r �sr of the ,� uriscif'c>aian - No permit pr�e to » give, ut j ority `ta v.io1ate orf cancel the pro visions of ;this code. shall . be val itirt 4. .' ; ;,, `' b� Project Name/Tenant: z'/i'77: /AP /Si*; /VSW /Gidi �i�C. , (.5 .Q.e-e tb ) /6 / /Ix 6/ b K g Value of Construction: .5 0-- Site,Address: City State /Zip: 1- 1L /S"9 /,.31/ /4 -- G /c"r..//L /4 A/4 9 &/61-1 62oV Tax Parcel Number. t7Lo/32O- 0 Phone: 2c 026 65/ Property Owner: /V0,12'77/ ST:pr /i/>4 r ..e,A 'Y7. J. fv4 , If yes, extent of change: (Attach additional sheet if necessary) Street Address: , / City State /Zip: 620 k_,,E e/. /) ' Uv f vi c. t n. /0 2- f�//x /CC,4,.1 9803 Fax #: Contractor: ' > - .Cp ';?1 4rri?-6 G /f 1c> ✓ /de Area of Construction: (sq. ft.) Phone: 1 / 204 2' 7'a Street Address: J/ W City State /Zip: Fax #: 206 Zz- /z/ 639 3 o Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: /••,,' ,, Contact Person: y^ / f •?; ./ ` , :, ! f � n � , � /Y , ` , . 7/v��/ �.�""�� +� ✓�� 7 '�.J f L'!L ✓it! �> ' • - .A r` (�';� Phone �} / /,, ..14-' � "�f�"� w Street Address: �, ' City State /Zip: this f S /.15 t 7A4: 9 3 /&8- 6 zo V Fax #: // Description of work to be done: , (.5 .Q.e-e tb ) /6 / /Ix 6/ b K g --�- /t�57/�G-L usi ei �ti -l=' / Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family Warehouse ['Hospital ❑ Church ❑ Manufacturing ❑ MoteUHotel ❑ Office ❑ School/College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant in Multi- family la Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel/Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes - TT no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? 71 yes ❑ no Existing fire protection features: 14 sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 3700 existing Area of Construction: (sq. ft.) Will there be storage of flammable /combustible hazardous material in the building? ❑ yes RI Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Commercial / Multi- Family Tenant Improvement / Alteration Permit Application CITY OF TUf WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT. REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Hauling ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted`. Dale application expires: ( - 9 Application to by: (initials) PLEASE SIGN BACK OF APPLICATION FORM CTPERMIT.DOC 1 /29/97 BUILDING OWNER OB-AUTHORI 5D AGENT: Signature: �� /7-71' Date: �f� .Z /J Print name: / � /� Phone: - 648 Fax It: a /....../(//11i..57/ Address i� -1j2fC City /State /Zip ALL COMMERCIAUMULTI -FLY TENANT IMPROVEMENT /AL 'ATION PERMIT APPLICATIONS MU, BE SUBMITTED WITH THE FOL • WING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack / \ layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ Cl Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ Cl Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 ACTIVI'T'Y NUMBER D97 -0280 PROJECT NAME ENTERPRISE INSTALLATION DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION p PLANNING DIVISION p PUBLIC WORKS STRUCTURAL 0 PERMIT COORDINATOR is 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE 0 NOT COMPLETE p COMMENTS TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF f (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS IMTIAL C:ROUTE -F femr Copy PLAN REVIEW / ROUTIN6' SLIP DATE DATE DATE DATE 12/4/97 DUE DATE 12/9/97 NOT APPLICABLE 0 I DUE DATE i 7/93/qv APPROVED ❑ APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) p DUE DATE APPROVED [1 APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) Punns& (ooy 6i no*t Cklb, PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0280 PROJECT NAME ENTERPRISE INSTALLATION INC. DEPARTMENT: BUII.DING DIVISION PREVENTION E PLANNING DMSION' 0 tk C 3/ORIW7 AUCTURAL C NRVi COO a INNATOR ■ .0 A - <61NDIcifi DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 8/26/97 COMPLETE a NOT COMPLETE NOT APPLICABLE E COTS TUES /THURS ROUTING: PLEASE ROUTE E NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE i APPROVALS OR CORRECTIONS: (ten days) APPROVED APPROVED WI CONDITIONS REVIEWERS INITIAL CORRECTION DETERNONATTON: REVIEWERS INITIAL DUE DATE APPROVED FT APPROVED W/ CONDITIONS E. NOT APPROVED (attach comments) 0 C:ROUTE -F DATE DATE DATE DUE DATE NOT APPROVED (attach comments) 8/25/97 9/09/97 (Certification of occupancy rcquirsd. ) City of Tukwila ,o hn W. Ra nts, Mayor Department of Community Development Steve Lancaster, Director Terry Bennett 4459. South 134 Place Tukwila, WA 98188 Dear Mr. Bennett: In reviewing our current permit files, it appears that your permit the installation of pallet racks issued on September 19, 1997 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Permit Status D97- 0280 4459 South 134 Place iclitr( Brenda Holt Permit Coordinator Xc: Permit File No. D97 -0280 Duane Griffin, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fay (206) 431.3665 roject: th'ter rfAce t ( �� ck1104� -t(A. Gc Type o spection: i F u t•Ik Address: 1 4471 aruct'ICJ 1-I "R ' l Date called: 3 n 1)F 0 P ructions: . Date wanted ? $— 2 -000 a.m. p.m. Reques : Pho ^^ n • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 a Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 COMMENTS: e ' , , L 44/ Date: 3_i: „yJ Corrections required prior to approval. 0 $47.00 REINSPECTION F EQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. Receipt No: Date: Projec • TType of insp c>)iod' il .Add estT J�1 , f ate called: Li -2 18 Special in?;tructlons: J ^n aims.- . *rl't S(6 L 1 � Date wanted: r� Q a'ir"i �l"� , �.. 1 U p.m. , 4 0''l{� `�' �' Request ---rk-e...e. Phone . :.._. 0 ilety • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per. applicable codes. Inspector; I I INSPECTION RECORD Retain a copy with permit PERMIT NO. (206) 431 -3670 Corrections required prior to approval. , Date: / $42.00 REINSPECTION ` frEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: (\ 6 N r r-, N L GIv4cl ■tt-ttJCI i.S cz>,rU a (,, rT- S1.bWS le 6,A. . , h :,:IC:v. IL �JtTS 13 In4 Gyro. 3 YL A,.m 4 4" 111I N • frrn 6,iT• rniT1ri". PA tttS'Ma1 -uc� -1 i s oNL1 3P2.." ern 6'�m•z..r .. c m4 X i''' et Go - ( L _ - Re u star: per: S3'1-GC/ 3 ) P & . r wN Ni SS i.i P C1s ' wlI 4 • SO S4.9.1. I 0 'q11,6% . Cpoa3u4.a CMG Q . IW s.-- - 1 sQ u m i TS Proj ..•_ Type of inspection: • Add`e$su S Date called:— —1(p —9 % C� . Special instructions: Date wants C Re u star: per: S3'1-GC/ G ong No.:1 40 — _7,76d0 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: Approved per applicable codes. Receipt No.: INSPECTION RECORD r� Retain a copy with permit Dr1 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: 3 r $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: k.:7 w<ti. • / <. E.•il„Y .j I . It4 1r t 3 '4�!`tYl y)14L .A Y.0 M "s Project Address Sprinklers: Fire Alarm: 1" Hood & Duct: A1 Halon: A/ Monitor: / Pre -Fire: Tv Permits: Authorized Signature FINALAPP.FRM City of Tukwila Fire Department .TURWILA,FIRE DEPARTMENT FINAL APPROVAL FORM 31/ (L. Retain current inspection schedule X Needs shift inspection Approved without correction notice Approved with correction notice issued 56 x./ LA 7 , •14 L 7 3 / e� ate T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. /,'9 7`© gCJ Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 1. *****4*****:k*** ************* ,• DITY OF TRAN8MIT i'****4**********44*****.***,* ****:* •*.* ********k4**********k#******* : 127.84 '08/25/87.:,14«,18 ENTERPRISE INC IMit: JP Pirmit No. ,' Dq70280':", :DEVPE:BM , DEVE:LOPMENT.UBMIT. ,.„. • • :Parcer.:NO,: : • •• . 4459 :S i34 PL Total Fees: . . 127.84 This. Pataeertt , - Total -ALL . 127.84' • • 3a1anc: .00 4.****** .„ Account 'Code DscriptiQn • Arnotint'' 000/322.40.0 . ,) , BUILDING - 'N8NRES.. 74.75 000/245.830 PLAN CHECK' - NoNRES • ' 48.59 6 :000/386.904 STATE. BUILDING SURC,FIARPE '4.50 • .., ^N'3x:n.. ....fin,. ..v ..r , deso?n ROCA • .•,.: S:Y.C. Daati) Permit No. FILE COPY : -- untie rstantl thattheTtan approvi4s -a ;ubiect to errors and omissions.a9d approvaiof r,► clues._. nQt .a.t4thorize toe' _vo)atio r of any t 30npteci cola• or ordinance..r3e4}eLPt or, con- tractor's copy of. • • roved p knovvi d. d. it ooPtCVAtalk i i-riz.z.x7zoiti SCALE:A :..._Z . _ SCALE: �rrra[tAna✓ /AC- : ter RECEIVED CITY OF TUKWILA PERMIT CENTER D'fl • °DS& •• f ooynnm ,„ Soutnworot Co • Wnst Sonngnolo Mass U1089 • JrCtlr NC. Js.'9 r- 0— E s- k ic i2E1ekrarg. Secno•vs - ADA EA • • 1:2, Re•A ee BUILDERS COPY . . v TYF't cA L IolM111••• SCA 1, = I , J�' Ci Y OF iuMVItA APPROVED 0C 51997 My 17 ntkiet tiui�.. )ING DIVISION O1iY ��� E p. APP SEP 2 1997 • RECEIVED CITY OF TUKWILA DEC fl 41997 PERMIT CENTER ':{E3)1St aJ RECEIVED CITY OF TUKWILA 7. r 1"?7 J' PERMIT CENTER Dc11-0M0 SY ::t77Cc3Y;�ttiiroa}Savri%a G . McKifzney S tructural Calculations for: Enterprise Installations Inc. 4 59 So. 134th Pl. Tukwila,Wa: August 25,1997 CITY OF AUG' 2 5 . 19 97 PERMIT CENTER 45,000 40,000 35.000 30,000 25,000 20,000 } 15,000 10.000 N - CAPACITIES BEAM CAPACITIES e E N 3 8 36 48 60 72 84 96 108 Vertical Beam Spacing, inches FRAME CAPACITY TABLE Use capacity of one frame to determine capacity of one hay. Load capacities are based on frames anchored to floor, in a straight line. Safety factor: 1.92 to I All frames are made from 50,000 psi steel. Frames are c 1 fabricated to your specific height as a cot ti i i, one-piece welded unit. Horizontal and diag nal bracing is 1.5" x I" welded tube for added strength. Welded footplates have ample room for lagging frames to floor. 'For vertical beam spacing greater than 108 ", consult manufacturer. BEAM CAPACITY TABLE Beam capacities are per pair of beams and based on an evenly distributed load, with frames anchored to floor Safety factor: 1.67 to I All beams are made from 50,000 psi steel. Beams are lapped top and bottom for added suergth. End plates with 3 load - bearing studs are standard 4 studs available upon request. Two safety clips provided per beam. QHF 40 QHF 34 QHF 28 QMF21. QLF 17 12,000 11,079 9,497 8,309 7,386 6,648 6,043 5,540 5,114 4,748 4,432 3,794 3,208 2,883 2,737 2,354 2,040 1,850 1,686 1,542 1.416 12.000 12.000 12,000 12,000 11,375 10,238 9,307 8,532 7,875 7,313 6,825 6,153 5,576 5,236 5,078 4,645 4,068 3.690 3,362 3,076 2,825 12,000 11,135 10,207 9,422 8,749 8,166 7,;36.7 6,671 6,265 6,076 5,557 5,103 4,860 4,480 4,099 3,765 1- --r 2 ,01 12,000 12,000 11,953 10,459 9,297 8,367 7,607 6,973 6,436 5,977 5,578 5,028 4,557 4.164 3,953 3,400 2,946 2,672 2,435 2,228 2,046 12,000 12,000 11,992 11,070 10,279 9,594 8,648 7,838 7,361 7,138 6,529 5,996 5,711 5,451 5,214 4,875 16,000 16,000 15,146 16,000 13,884 15,879 12.816 14,658 11,901 13,611 11,107 12,703 10,013 11,451 9,075 10,379 8,522 9.746 8,264 9,452 7,559 8,646 6.942 7,940 6.611 7,562 6,311 7,218 6,037 6,904 5,735 6,616 3 I' I A 9I /I6"I 1.01( I /f KWlK lir>I ►�f►l .4 I /V' ( IYPI CAL ) EaI4 AIM is Comb 1.16/16' 2.3/4' 1.1/2" 3' 4.1/2' 2.1/4" e 24/4' " 1•I/2' 6334" w 3.3/4" e•1 /P 1.3/1" 44411411 1160 3064 3102 3 61y1 63N 1111 1341 siii 11 NN 231e 2361 a 1" 4 • •" 1 ' 101/4' wee (SEE SKETCH ON PREVIOUS SHEET) DETERMINE CONCRETE AND ANCHOR BOLT STRESSES DUE TO DL, LL AND SEISMIC LOADING IN THE TRANSVERSE DIRECTION: Pc = P(DL +LL) + P(SEISMIC TRANS.) = 8.87 k BOLT AREA, As = 0.20 sq in A =B *N= 8.00 *5.00= 40.0 sq in Sy =B *N ^2/6= 33.3 in ^4 f N/2 = (5.00/2) = 2.50" BASE PLATE LOAD TYPE: Smax = 0.22 ksi Smin = 0.22 ksi tp BY: BAO / REV. C / 11.03.93 a) UNIFORM NO ANCHOR BOLT TENSION DUE TO MOMENT Pt = 1.78 k ANCHOR BOLT TENSION DUE TO UPLIFT BASE PLATE DESIGN PROCEDURE FROM AISC 9TH EDITION pp 3 -106 THRU 3 -108. fp = 0.22 ksi DETERMINE tp: m f p 0.136" 0.25fy *1.33 tp n f• = 0.340" < GOVERNS 0.25f *1.33 ACTUAL tp = 0.500" > 0.340" OK BENDING DUE TO UPLIFT: MAX Pt = 1.78 k M= Pt *(n -x)= 2.664 "k S = (N * tp ^2)/6 = 0.208 InA3 fb = M/S = 12.79 ksi Fb = 1.33* 0.75 *Fy = 36.00 ksi > 12.79 ksi OK 3/4 FILENAME: TMPPRK02.XLS 8/25/97 12:07 PM iS/25/ DETERMINE CONCRETE AND BASE PL STRESSES DUE TO DL AND LL: BASE PLATE LOAD TYPE: UNIFORM DETERMINE tp: Smax = 0.10 ksi fp = 0.10 ksi ACTUAL tp = 0.500" CHECK ANCHOR BOLTS: 0.260" OK MAX Pt = 1.78 k - MAX V (PER BOLT)= 040k ANCHOR BOLT TYPE: HILTI KWIK BOLT II NO SPECIAL INSPECTION SPECIAL INSPECTION?: NO 0.500" DIAMETER: EMBEDMENT: 3.500" TENSILE CAPACITY = SHEAR CAPACITY = INTERACTION: BY: BAO / REV. C / 11.03.93 MAX Pt 1.24 = 0.53k 2.40 k 2.45 k MAX V TENSILE CAPACITY SHEAR CAPACITY 1.776/2.400 + 0.402/2.450 = = 0.740 + 0.164 = 0.904 W/O 1.5 FACTOR = 0.387 1.00 OK 5 1,00 1.00 OK IF 1.5 FACTOR NOT USED 4/4 FILENAME: TMPPRK02.XLS 8/25/97 12:07 PM LOADS: N = 5.00 " B = 8.00 " d =-• 300" bf = 3.00 " x 1.00" PIER SIZE = 1296 sq in Bolt dia = 0.5 " MATERIAL PROPERTIES: fc' = 4000 psi Fy = 36 ksi Es/Ec = 10 P(DL+LL)= 3.90 k LONGITUDINAL- P (seis)= 1.86 k M (seis)=. 0.00 "k V (seis) = 0.80 k TRANSVERSE- P (seis)= 4.97 k M (seis)= 0.00 "k P(uplift)= 3.55 k V (sels) = 0.54 k BY: BAO / REV, C /11.03.93 min S min Pt Y Pt + Pc LOAD TYPE: I S ma o) UNIFORM S mox b) TRAPEZOIDAL I S m „ c) TRIANGULAR 1/4 FILENAME: TMPPRK02.XLS 8/25/97 12:07 PM • .... ., _-: - 'REVD . 8125/97 DETERMINE CONCRETE AND ANCHOR BOLT STRESSES DUE TO DL, LL AND SEISMIC LOADING IN THE LONGITUDINAL DIRECTION: Pc = P(DL +LL) + P(SEISMIC LONG.) = 5.76 k BOLT AREA, As = 0.20 sq in A =B *N= 8.00 *5.00= 40.Osgin Sx= N *B ^2/6= 53.3InA3 f= B /2 -x= (8.00/2) - 1.00= 3.00" e = M /Pc = 0.00/5.76 = 0.00" BASE PLATE LOAD TYPE: a) UNIFORM (SEE SKETCH ON PREVIOUS SHEET) Smin = 0.14 ksi Smax = 0.14 ksi Pt = 0.00 k . NO ANCHOR BOLT TENSION BASE PLATE DESIGN PROCEDURE FROM AISC 9TH EDITION pp 3 -106 THRU 3 -108. m =(N- d)/2= (5.0- 3.0)/2= 1.00" n = (B - bf) /2 = (8.0 - 3.0)/2 = 2.50" fp = 0.14 ksi A1 =B *N =8.0 *5.0 = 40.Osgin A2 = . 1296 sq in (Pier size) DETERMINE tp: tp =m fP 0.25f *1.33 tp = n f P = 0.274" < GOVERNS 0.25f *1. 33 ACTUAL tp = 0.500" > 0.274" OK BY: BAO / REV. C / 11.03.93 = 0.110" 2/4 FILENAME: TMPPRK02.XLS 8/25/97 12:07 PM REVISION SUBMITTAL DATE: i-D' "J PLAN CHECK/PERMIT NUMBER: 5 7 PROJECT NAME: � e. PROJECT ADDRESS: 4/6" S l S / 347 PZ CONTACT PERSON: REVISION SUMMARY: CITY OFiijKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Gt-e a SHEET NUMBER(S) • "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: 7, -(- 4- "\-- CITY USE ONLY Bldg. 'Planning >* J)` RECEIVED CITY OF TUKWILA DEC 041997 PERMIT CENTER P�P PHONE: c . 4 c� - Public ;Works CITY OF TUKWILA T\PPR0VFD DEC 5197 0.0 I ,u 11`u IViSi.�.,N ciAti 3/19/96 City of Tukwila Fire Department E a � i cl co Fire Department Review Control # 07/1,-0a0 Re: Rack at e4 p(ije Z 1 � n5 fri /afO I Dear Sir: q L/59 55 (3L-/ l The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Storage may not be closer than 36 inches in all directions to ceiling -hung "Space or Unit" heaters. (UFC 1109.2) Storage may not be closer than 18 inches below sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1) 2. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) Thomas P. Keefe, Fire Chief 3. Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 231C, 3 -2.3) 4. Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57$4404 • Fax (206) 5754439 Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief 5. Depending on the classification of the commodity being stored'and the size of the storage area, smoke vents and curtain boards may be required by Table 81 -A of the. Uniform Fire Code. Contact the'Tukwila Fire Prevention Bureau for further information. 6. Depending on the classification of the commodity being stored and the storage height, in -rack sprinklers may be required per N.F.P.A. 231C. Contact the Tukwila Fire Prevention Bureau for further information. 7. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. 8. High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 57544 39 truly; , 9 o ��e, Cit o f Tukwila J ohn W Rants, Mayor: W t 'V. \ t 0 e ye , - Fire Department Thomas P. Keefe, Fire chie 1908 sa rSn 1y Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 STATE OF WASHINGTON COUNTY OF KING AFFCONT.DOC 5/29/96 SS. AP' LI' ' NT CITY OF T. "WILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 S 7�' ��� , states as follows: 1. I have made application for a building permit from the City of Tukwila, Washington. lAr My commission expires: r...nxnregm......+W -ryr. aLnret trym.F*hNa.t ?a'5 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION CITY OF KWILA SEP 191997 PERMIT CENTER 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. /c- , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Signed and sworn to before me this /(14')� day of v�hc.- 19 97 NOTARY PUBLIC in and for the State of Washington, residing at V) County. Name as commissioned: ,tirtfk Uur e.✓ la—cc-6'65 18.27.090 Exemptions. This chapter shall not apply to: 1. An authorized representative of the °United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; AFFCONT.DOC 5/29/96 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well.or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operatron is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work.