Loading...
HomeMy WebLinkAboutPermit D97-0297 - STENSON CONSTRUCTION - LOT B - NEW RESIDENCEParcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: City of Tukwila t- Contractor 336590 -0107 14258 55 AV S 14258 55 AV S - LOT B NSFR DEVPERM V -N GAS 001 North: .0 South: UNKNOWN Sewer: Slopes: License No: FLEESI * 122CA: Permit Center Authorized Signature: DEVELOPMENT PERMIT This permit shall become null and void 180 days from the date of issuance, or for a period of 180 days from the last j Print N a l e : _/f_ !I Fire East: (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: Status: Issued: Expires: Occupancy: UBC: Protection: .0 West: Streams: c2f-- 097 -0297 ISSUED 02/18/1998 08/17/1998 DWELLING 1994 0 OCCUPANT STENSON CONSTRUCTION LOT B 14258 .55 AV S,' `TUKWILA, .WA 98188 OWNER BENNETT DARLA D Phone:. (425)228 -5149 13617 SE 141ST ST, RENTON WA'98056 CONTACT LEE STENSON Phone: 431 -5159 144 S.W. 153RD, SUITE C, BURIEN, WA 98166 CONTRACTOR F LEE:STENSON INC, Phone.:. 206:431-5159 :1 153RD, SUITE C, BURIEN, WA 98166 ..************4************************'***** l********** * * * * * * * *4 * ** * *li *. * * * * * * * * * * * ** Permit Description: CONSTRUCT NEW SINGLE- FAMILY.RESIDENCE 2,078 S.F. WITH A :.GARAGE 488 S.F., AND.AN UNCOVERED, PORCH. 432 S.F. REMOVE PART OF THE EXISTING.ROCKERY AND CONSTRUCT NEW 8 FT HIGH RETAINING WALLS TO ACCOMMODATE NEW DRIVEWAY. CONSTRUCT NEW .4" SANITA- RY SIDE SEWER, NEW 3/4". DOMESTIC WATER SERVICE. WITH NEW:WET TAP & NEW 3/4" PERMANENT WATER METER, AND NEW.:STORM DRAINAGE. r***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 159,993.66 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: JJS Curb Cut /Access /Sidewalk /CSS: Y Fire::Loop'Hydrant: N No: Size(in): .00 Flood Control`Zone: N Hauling: N Start Time: End Time: Land Altering: Y Cut: 336 Fill: Landscape Irrigation: N Moving Oversized Load: N 'Start Time: End Time: Sanitary Side Sewer: Y No: 1 Sewer Main Extension: N Private: Public: Storm Drainage: Y Street Use: N Water Main Extension: N Private: Public: r**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 2,369.96 -******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ************ •* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date:_ 2.18 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I any authorized to sign for and obtain this development permit. Signature: (t Date: ��rp if the work is not commenced within it the work is suspended or abandoned inspection. r •'• Status. 'Applied Issued * **: *•k * 4**•k*kk* Permit No: D97 -0297 .I'SSl1ED. . 09/09/1997 02/18/f998 *•k.*k * ** ** *'* Address: ..;14258 5 Suite• . Tenant: Type DEVPERM arce`;1 # 336590-0107 *******• k*• k• k*•k'k•k'k *k *•k'k** * * * * * * * *•k* Permit Conditions 1 No changes will be made to the plans unless approved by the Architect or Engineer hwi Building - Division. Plumbing per mi ss 2t , s � e fn ,; it ed ttu ough the Seattle-King ,County Depart ; i�-P i is He 4ipt <ng will be inspected "k ht'"�a ery- incl ,ding al i`d i in k:. Yx �4, p g y Ele l r 's 1 l rte ' o'bt : reed � cigfi`tbe Washingtbh . E �i�'�'�sic, `Labor a idustri and 1 e • 1�� ytt� t r • i c a l. wo, k rr f ,Ce i pe c ry te.d * by . that a � ' ` n�c•y (24-630)"'» Al1. i.ani c �a,k�''worrk sha,li"1 bei under separa petjuieAt, :,s ued 0 ty of� T uk0'i l'a,. s /' • r gr Kr. pe,rmi.ts p i,}nspec t on , recor s and approved ip4 =a> ‘WI ilAb a atethe job efte pryfr. to the .ta of ny con'. on. ' These - documeectsAre to be ma intairied . i a. i l ur .ti l f in ;respect 'ti approval i,s , grantoci: e :4 ( ny <ner� cey'i 1 ing gzTid° alnl1 ight,- F instal latio, ,i"s •, y e u i re d . rt, o m e't l a t.e ra+ �, g .� < `` �.:, � �ra�r~�� •r• t�pr� � ����m Zone 3 • ; �n r _;'�. r . l p P ar # on: a 1-- 1 -s.,at, Achecd to e 1i,l' + yid must be 1` t l: mull �" i; , � � �g 3.LF,� a be i� race. iif over e ig h tµ • 8' f e et• iin leng•t• 3 t o l ores r'u i o to be o eg • Nine {in\jtontorm nce with apps" pi ane, and requJ of the ,.ltnT:ilvlm Building : Code �4- , 911 .- E i; fin a : amende .In i,f o rr' , ech:a " ~R Code t 1 Ea 4, ) 'ndW s'in`gton State Ener `� 9 s; s us 9y �'md x..l 9 ��'E t i o n.� „P- of Wi ns I ] i i `Y * o'f� Permit . The i s 1 fig •c e o a� . r � ' (� .t�Y � �, �� � � ._. ,p� -r^mi t „�c�r� a��fit' �a �a <, 1s;pec'i.fications, and uta ., , h al not:Kb - s ^,ued to be.aa permit for, J aom i”- an a•p a;1 of any violation t' visions of ithe build n ir i ; g g: ode or of an r Dthe,ti ar•din " cn � f the jurisdiction N o,, � - per�p, pres to give,,` rtho i`, �r toav,iolate or cancel the' pr ov , /6f'this code A t ll 'be''valid. e /to a f, 10: Notifj?�t11 City of Tukwila`"Bu'ilding Division prtoit /to placing`40,,concrete. 44fS., pr' fee l {'e is in axit1°'�i''ion to re uirements ••f speciaYl ' p • } t � 11. All wood to ri i r i 11 -4 ' } werf, r n p &old ;� o ncr t o s b a:l:zi.b e treated wood. 12 There shall l be"' an of th b .• - . ,� , c � � . �? :._..._ y tee.. ��-the Tukwila Building Inspector. � f,�:ri � t :>) until tit e final inspection h•as: ;baK'enxr; . R gt:6d.,..6 r . , 13. Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off - site or into existing storm drainage facilities. 14. The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 15. Driveways shall comply with City residential standards. Driveway width shall be a 10' minimum and 20' maximum. Slope shall be a maximum of 15.. Turning radii shall be a minimum of five feet. 16. The driveway shall be designed and slop.d so that drainage from the driveway does not flow onto the existing road surface. 17. Dr-ivewa s shall be eyed for a minimum distance of 20' from any ,he e„..,: o f ; . e ris t ing road pavemen !or ^k a,ff ec t ;ing ' f;lows be_. c lo s ely coord at ine y si th tt e 'C1 t . U'ti l it.ie In Traffi :Contro•l Plan ;hall die submit -to the I s :for prior• : app u ov 5 A c ,y shal l_; re • app� ca on f tior ' a H auling ` ermitjp t o:;any: as so`ci a 't ed a s recommend t hat storm designs be • err .ed by a : i ce n s ed ' engineer,: othier . owner :: a ssu mes. 1. i ab i 1 i ty for t he desi : and `.any <s ubse.quent rre.1 •ate i amage r e water m sh be: located t .ity,r i ght f vay a ti :th e' pr t y l in :; wi hin G FIiE N 12 " "+TOR .DRAIN SYSTEM ON', AVE s sh all be fURNEDO .TO TH CI.T'r' along; with appropriat • d o c ume n t tion prior: to :the FinJw II ` t i te Project Name/Tenant: -- -. .. .. .. Value of Construction: $110.000.00 _- Site Add ress: ! u &5� ► V City State /Zip: §t Tax Parcel Number: 11659O—n107 . _ Ttnkwi1a Wa 98188 Property Owner: F. LEE STENSON CONSTRTTCTInN, INC_ Phone: 431 -91c9 Street Address: City State /Zip: 144 S. W. 153rd Suite C. Burien. Wa 98166 Fax #: 431 -1274 Contractor: F. LEE STENSON CONSTRUCTION, INC. Phone: 411 -5159 Street Address: City State /Zip: 144 S. W. 153rd Suite C. Burien, Ida 9R16h Fax #: 4'11 -1 99G Architect: Dongald Atwood Phone: 935 -2712 Street Address: City State/Zip: 4316 30th Ave. S.W.. Seattle_ Wa 9R176 Fax #: 911 —R075 Engineer: Phone: Street Address: City State/Zip: Fax #: Contact Person: F. T.PP StPnsnn Phone: /13 5159 Street Address: City State /Zip: • 144 S LI 1 5 "1,-.1 c,,44-,-. r n....: , r,_ 9R 1 AA F ax #: it'll 1 ") 9 Description of work to be done: New construction single family residence'.-' COn5f(OO`f -ioP of RocKQr Type of work: New Single- Family Residence ❑ Addition - Single - Family Residence Interior Remodel- Single - Family Residence ❑ Residential Accessory Structure' ❑ Remodel /Addition to Accessory Structure ❑ Garage(s) ❑ Deck(s) - Covered & Uncovered ❑ Residential Reroof Is this site served by: ® Sewer ❑ Septic (King County Health Dept. approval required - 296 - 4722) Existing Square Footage for Structure: sq. ft. Dwelling sq. ft. Covered Deck(s) sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck Proposed New Square Footage: 2,078 sq. ft. Dwelling sq. ft. Covered Deck(s) 488 sq. ft. Garage /Carport sq. ft. Accessory Structure(s) 432 s lyn Deck Floor Area Ratio: (total floor area of all structures divided by the area of the lot) *For an Accessory dwelling, provide the following: Lot area Floor area of principal dwelling Floor area of accessory dwelling ' Provide documentation that shows the principal owner lives in one of the dwellings as his or her primary residence. CITY OF T''CWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 JOB 709 OR STAFF USE ONLY Project Number: Permit Number: Single - Family Residential Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST. FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews shall be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Hauling ❑ Land Altering: 0 Cut cubic yds. 0 Fill cubic yds. ❑ Moving an Oversized Load: Start Time: End Time: ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be re- viewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall ex- pire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: (4 Date application expires: Q �(C l ~ -! 1 , Application takg by: (initials) PLEASE SIGN BACK OF APPLICATION FORM SFPERMIT.DOC 2/13/97 BUILDING OWNER OR AUTHORIZED AGENT: Date: 9/9/97 Signature: r �� ,� --''� -7. Print am , -' I ~�-"" - F ' . 1 ; EL STINSON, PRESIDENT Phone: 431 -5159 Fax #: J 431 -1224 Address: 144 S. W. 153rd Suite C City /State /Zip: B u r i e n, Wa. 98166 ALL SINGLE- FAMILY RESIDENTIA • ERMIT APPLICATIONS MUST BE :MITTED WITH THE FOLLOWING: DRAWINGS PREPARED BY . iEGISTERED ARCHITECT OR PROF,- 4SIONAL ENGINEER MAY BE REQUIRED BY THE BUILDING OFFICIAL ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Q Copy of recorded Legal Description from King County ❑ ❑ Certificate of water /fire flow availability (Form H -11a). Contact the Public Works Department (206) 433 -0179 for servicing district. ❑ ❑ Certificate of sewer availability (Form H -11). Contact the Public Works Department (206) 433- 0179 for servicing district. ❑ ❑ Metro: Residential Sewer Certification (if Tukwila Sewer District) (Form H -12) ❑ ❑ King County Health Department approval for septic - 296 -4722 Four (4) sets of working drawings, which include: ❑ ❑ Site Plan (see example Form H - 16) 1. Existing fire hydrant location(s). 2. Proposed access road. 3. Driveway location- driveway shall be 10' wide minimum and 20' wide maximum. If driveway is over 150' long, driveway shall be 20' wide and have an approved turnaround (City Ordinance 1741). 4. North arrow and scale. 5. Building setback from property lines. Any proposed or existing easements must be shown on plan. 6. Public Works review requires the following on site plan: driveway location (10' min., 20' max. width), show proposed and existing power, water and sewer lines, existing storm drainage system, downspouts and foundation drains, and where drains tie -in. 7. Parking plan. 8. Lowest building elevation (if in Flood Control Zone). 9. Estimated /proposed topography at 2' intervals and proposed elevation of lowest floor level. 10. Identify location of sensitive areas slopes 20% or greater, wetlands, watercourses and their buffers. 11. Identify location and size of significant trees that are located in sensitive areas and buffers or the shoreline zone. Of those, identify which are to be removed (Title 18, City of Tukwila Zoning Code). 12. Identify location of high water mark of the Green /Duwamish River if site is located within 200' of the high water mark. 13. See Public Works Checklist for detailed site plan information required for Public Works Review (Form H -9). ❑ ❑ Foundation plan and details ❑ ❑ Floor plan ❑ ❑ Roof plan ❑ ❑ Building elevations (all views) ❑ ❑ Building height ❑ ❑ Building cross - section ❑ ❑ Structural framing plans and details necessary to completely describe construction ❑ ❑ Washington State Energy Code Data (Gas /Electric /Oil /Propane /Heat Pump) Form H -15 available at Permit Center OR Prescriptive Heating System Sizing Chap 9 Form H -6. ❑ ❑ Complete Land Use Applications if not previously submitted (i.e., Reasonable Use Exception, Variance, Shoreline or Tree Permit). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance and other land use or SEPA decisions. ❑ ❑ If dwelling has a septic tank, and a bedroom or bathroom are added, provide written approval from the King County Health Department or the Tukwila Public Works Department prior to submittal of permit application. ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. SFPERM1T.DOC 2 /13/97 k,* k; bkk•d* kk*• k* k** kikkkk**" kkA*. k* k A• khlA 4.• kk: 1**., l#. •k:thA+1Ir,tA“•k4.*t *4•k OP: , .TRFP15M3 "T. k* h* k•l** A: kk *4e.A?t:l.?ek *1.* *k•A. *•k **k rol#* *•A *Ak *.:4•kk *'.=k /i l * *. *•k *.4*A*k * T. NSM ;21 �lilmbar:: 89700715. :Amnlnt. 1.',59.8.25 02/18./98..12:22 Pa me : 14 hn:d: `CH CIt .,: No:i- .,z.t.�an• I .: LEE .STENSON Inita::ULli, Perrmit. D97 -0297 ,.': Type, DEV.P.EUiI DEVELONME,N1 "PERMIT. a Prscel: : 336590- :01:07 B is d dy: S Lcic at i n : 14258 55 'AV 8 LOT: El :Tat "al l a :' 2,361.96 T,atal ALL".P.m:ts: 2,36:9.96 B e l ante: .00 , itiv *A ** ***A *• ** * * * *.*4, ** * * * *3* *A *A.ki *•a * o,mk * ***• * *•AA*•il *•* * ** Dc c•r'iptIon BUILDING RES PLAN CHLCI( UTILITY PLAN CHECK IWATI::R METER S:TATE,,BUll_DING 'SURCNf INSP: FEE.. UTILITY IN5N f EE 7 13TORtl :DRAIU INSP FEE -• -SME " /SSS WAT[ CONNECTION : , !'1AIER .INSTAL.L.ATION. (DEP) WATER INSPECTION FEE WATER •TURN FEE LAMS ALTERING PERMIT FEE L.AN.E) ALT ERINO .CHECK,. 22.50 f i s ,Paym Account Cade 000/322.100 000/345,830 000/345.830 000/386.904 060/342.400 412/342.40 402/ 401/388.:102 401/386:520 4'01/342. 461/343.405 000322.1 000/31 •8+80.. • Amount: 1,187.25 20.00 10.00 4.50 15.00 15.00 20 60,.00 - 1;,0.00 15.00 25.00 ;.4.00 -"— ...; . t7 •02/1r - 97I ' 'TOTAL' ._ 1598,25 • , . • , • , • ' ' • ' R. • 1: TR Not ti '• LEE STENSON Iiit: 0111 it N a • D 9 770 2,9 7. Type: EV PER it! ..1}E V E LO P N.TH PERMIT ...„. . , . , . „ .:,„ . • . ••• Parcel Wo: 336590-Ole? .P R CEL D • • •I • • !rota 1 1,963.46 „ • inertt•:; • Total ':' ALL. ,Pmts • • • • • • • • ira O e 1,191.75 • **** ,%.** ik if44,*•*.*:***11,4*4.*** 1c11.4,(11.***.,* * • * • Account Code Decript ion • • Arncuit • V:; , : , . , , , ' 1:100/.315.830 - - • • PLAN CHECK RE - . • 71 • •,•..;'.."•.• • eAgrutiLA SEP 0 9 1997 3903 07/10 9717 TOTAL 771.71 -•,, ,^-•-,„•■ .'" INSPECTION RE D Retain a copy with plrinit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 COMMENTS: Inspec pproved per applicable codes. PERMIT NO. (206)4313670 Date calfe.: Date an : a.m. p.m. Phone: Corrections required prior to approval. • , • • .„.. . • . • ,• . • • • • • ' • • . • • , • ".• ' ' '• ,• , • • . . 'AIPP/7 Ar dit ///,/ $47. I REINSPECTION FEE REQUIRED. Prior to insp ction, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call td schedule reinspection. Receipt No Date: • • , Project: '. r Lee S- -ensan Type of Inspection: PW Final Address: • 1 55 Ave S Date called: Z- g_ 9q :Special instructions: . Date wanted: a.m. 2 -q -�q . Requester: e Phone: 2 2 , $14 26 M kn ?ntry tr' X17atr ktk?f1'ea "w +u'.7v$lji'M` -7 PERMIT NO. INSPECTION RECOR Retain .a copy with per INSPECTION NO ITY-OF TUKWILA BUILDING DIVISION 300 :Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. (206)431 -3670 Corrections required prior to approval. COMMENTS: ,70/C f Inspector: Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: :,�' • INSPECTION NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 COMMENTS: INSPECTION RECORD Retain a copy with per PERMIT NO. (206) 431 -3670 Project: Type of inspection: ccA5 55 Date c alled: ' .. w P- -etp{ Date wanted: Special instructions: a.m. p.m. Phone No.: Corrections required prior to approval: Inspector: Date: 15/5? I $42,00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date; project:' , ,,, L e , n5077 Type of Inspectioniq . , (..... Address L..., ., hk 6 , , iika,5 6 55 -"r Date called: c26, Special instructions: , .. . Date wanted: - "W a.m. • • Requester:6 Phone: •n. COMMENTS: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. '• CITY OF.TUKVVILA BUILDING DIVISION ' 6 Southcenter BINid, #100, Tukwila, WA 98188 (b A/a) &dd./re-Ss 07 04Q97 q kAwei (Pite4 6L4 6 44.44-4(.4* 5 - (>t ett 44-e..look S" SfUt4 c.otlpi) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: 44.0. PERMIT NO. (206)431-3670 • Corrections required prior to approval. Inspector: j Date: 4 Date: • • Project: _ 5 Type of InsOctiop: lie-A A.5 s —11 14 Addiesta 6 - s -1-1,0 c , Date called: . Special instructions: tp . . . 1 Li 2 Date wanted: f / a.m. 01 Requester: Phone: q31_5( 5 • INSPECTION REc Retain a copy with p it • 'INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION ..f.oci Blvd; #100, Tukwila, WA 98188 0 fr a 7 PERMIT NO. (206)431-3670 •-• Approved per applicable codes. NRZorrections required prior to a p p;OV COMMENTS: Aci or 16---A-1>cf SEE. P ' /1 1 I FA r I P 47.0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: ' t . . •Typeof Inspection: .Ad re frs:, ; Jo ' • I Date c - . ..------,-_ Special.instructions: . •y4(A).5 s . .5 ' 5 -...: '• - 5. e Ci,„e..-rfR. • • , • - --- ,. I.L; ./-3r•C G y Date w,injed:/ 7/ 9 1 ( a.m P.m. . Re9tkes en. C.,--, re Phone: COMMENTS: INSPECTION RE Retain a copy with Approved per applicable codes. Inspector INSPECTION NO CITY OF TUKVVILA BUILDING DIVISION 6300 Southgoter Blvd, #100, Tukwila, WA 98188 (206)431-3670 • .4 ID '7 PERMIT NO. Corrections required prior to approval. $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid . . • at 6300 Southcenter B vd., Suite 100. Call to schedule reinspection. L •• Receipt No: ... „ . . . .... .-;:.,,::, :. ,,,,,,,,,,, .‘. Date: Projec `-rPtSor/k Co Type of inspection: v4.-pav kawirv v. F1 ' Ad r sg 2 f-� S � - 5 Date ailed: t l �- Special instructions: Date wanted: t 1' a.m. r Requester: 1. I 1.. /.. Phone No.: in i INSPECTION NO. PERMIT NO. Approved per applicable codes. COMMENTS: II INSPECTION . R '�R Retain a copywi Jermit CITY OF TUKWILA' BUILDING DIVISION 6300 • Southcenter Blvd., #100; Tukwila, WA` 9818 (206) 431 -3670 Inspector: Date : 11.- I I Corrections required prior to approval. $42.00 REINSPECTION ( E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: SPECTION R Retain a copy wt INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 9818 Special instructions: Eqo, Type of inspection: Address: ii.../ Date called: Date wanted: 0 Requester: Phone No.: Approved per applicable codes. COMMENTS: Inspector: RD' � rmit Date: D77-02-771 PERMIT NO. (206) 431 -3670 Corrections required prior to .approval: JJ / ILid -7 it $42.' INSPECT! s� EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: :5: o a t: Pr ,Lo+ B Type of ins ection: 4 6 r-, .Address: .Address:, 5 -✓ S Date called: L 10(27 1 Special instructions: /71-5-4. Date wanted: 10 8 -1 � a.m. Requester i 0 Phone No. Wolt INSPECTION NO. CITY OF,TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: • INSPECTION R RD Retain a copy wirmit Receipt No.: Date: g PERMIT NO. (206) 431 -970 $42.00 REINSPECT f% FEE REQUIRED. Prior to inspection, tee must be paid at 6300 South enter Blvd„ Suite 100. Call to schedule reinspection. Project: i Type of inspection;,. Date called: � ! )7/- Addres . Special instructions: r ` el I C {•,, 1 , f � .J 6 Date wanted: 1 a Requester: Phone No.: INSPECTION R RD Retain a copy .wi � rmit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes, CO ENTS: Inspector 4111 Alr—s Date: 0 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42, *0 ' INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No,: Date: Project: Type of i spect' Address. Date called: Special instructions: !f . / . f 1 ' �.. Date wanted:/ Requester: Phone No.: Inspector: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 J Approved per applicable codes. COMMENTS: Le 4, /.4_, 54,-4 k-o--)7 /-1 4* L1 [^] $42.00 REINSPECTIO r FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [ReceiPt No.: INSPECTION RVIVID Retain a copy wi 'rmit I PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: INSPEC11ON NO, CITY•OF TUKWILA. BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspecto Date: PERMIT NO. Project:. . ( »J-( Type of inspection: Address: / ). � Date called: Special. instructions: Date wanted: /C) f � � 1 � :m: Q,iii .Ca Requester: Phone No.• �v �- X1"'1 r�i l a �/?�,( ,-- i 5 EUREISegiwatansm Corrections required prior to approval. 1 Receipt No.: $42.00 REINSPECTION FEE REQUIRED. " Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: NamittwalmagatIMIIMPARE 7 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 COMMENTS: Inspect° Date: PERMIT NO. Project: J Type of inspection: Address. Date called: Special instructions: • . Date wanted: !/, , Requester: Phone No.: J (206) 431 -3670 r Appfoved per applicable codes. 1 Corrections required prior to approval. n $42.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection, Receipt No.: Date: Proje Ipp Type pf o Address I4 -�.s.� SS/vs D ate called: ( I 0 4 ( qs ,, Sp e al instructions: .4.. „ C�C'� � C-0- Date wanted: 1 Q 1 S q r ' f a.m. p.m. Requester: Phone No.:�� (S�o �/' 3 5211.9'110 3FISS INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter .Blvd., #100, Tukwila, WA 98188 I Approved per applicable codes. INSPECTION R ' RD Retain a copy wi►� rmit pci '1- W17 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. r $42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ject. INSPECTION R D Reta a copy wit mit INSPECTION NO. PERMIT NO. CITY OF. : TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 (206) 431 -3670 P . Typ f inspe Ion: v O v # vii Tr f,.4 c k vt Addre s; . ,... Date called ' c� )380 d EAs ; YiY io 7 �S Special instruction s I r'a Date w�nt d a.m. 1-�lc N . ' (.� ar o� C' Uo7 f q' p.m. Re s er: `�' ,.. {'t� `�'�. Phone N OMMENTS: Corrections required prior to approval. Inspector: be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. f Receipt No.: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must Date: Date: 111111 1,{ INSPECTION : R eft D : :. ,' Retain a copy wit 'mit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter. Blvd., #100; Tukwila, WA 98188 Project ��k'Fype of in f... � -r te. Address: Date called: Special instructions: Date wanted: a.m: l " 7 /I J - 4 . J Requester: G,� f ir- �-�� S � 2 � 6 / / � � / � o Phone N o . : "C f'�—�% c''r7 COMMENTS: Corrections required prior to approval. PERMIT NO. (206) 431 -3670 1 /L1/, 17 $42.00 REINSPECTION S EE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Inspector: Date: Date: 1. 111111 1,{ INSPECTION : R eft D : :. ,' Retain a copy wit 'mit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter. Blvd., #100; Tukwila, WA 98188 Project ��k'Fype of in f... � -r te. Address: Date called: Special instructions: Date wanted: a.m: l " 7 /I J - 4 . J Requester: G,� f ir- �-�� S � 2 � 6 / / � � / � o Phone N o . : "C f'�—�% c''r7 COMMENTS: Corrections required prior to approval. PERMIT NO. (206) 431 -3670 1 /L1/, 17 $42.00 REINSPECTION S EE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Inspector: Date: Date: Project: 5--en soh Type of inspection: CUy b Cu t Address: +j , l Z sB 5 , AveS Date. called: q 28- q8 Special instructions:.. Date wanted: 9 _ 29 _ 9 ,, 0 : p.: Requester: Lee 5+e n s o vi cc Phone No.: 20!;/ 31 _ 5 15 e _� �.s�. fir,.. INSPECTION NO. CITY,OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. 1 Inspector: INSPECTION RECOR Retain a copy with per, I I Corrections required prior to approval. COMMENTS: Date: to [I] $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [ceiPt No.: Date: INSPECTION RE D Retain a copy witimit INSPECTI Date called: Date wanted: Phone No.: `(0... 9ici 9 Approved per applicable codes. Y v Corrections required prior to approval. Receipt No.: • . • $42.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Date: Date: :s CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.; #100; Tukwila, WA -98188 Project: Type of inspection: PE MIT NO. (206) 431 -3670 Project a Type of inspection} 00. a Address: ` -mss+ Dte called: Date 07/F? Special instructions: Date wanted: m. Requester: 0701 LP- Phone No.: ' y3,_57Sf } .tst • `_ ^;+i• .• .INSPECTION R R Re a copy wirmit • INSPECTION NO. CITY OF. TUKWILA. BUILDING DIVISION .6300 Southcenter Blvd., #100, Tukwila, WA 9818 L14. per applicable codes. f Receipt No.: riVo..2q7 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: i ilk Al i AIM Date: IN I Til A. 11 rL111 r $42.00 REINSPECTIO r FEE REQUIRED. Prior to inspection, fee must . be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Pro'e t: Type of inspection: Address: Date called: Special instructions: Date wanted: r 7 ,4Sf1' i° 1 /6, �I i ,a , Reque,ter: P one No . COMMENTS: Approved per applicable codes. cog ,213'7 (206) 4 Corrections required prior to approval. Date: [! $42.00 REINSPECTION FEE REQUIRED. Prior to inspect on, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: I Receipt No.: Date: el. am. '11 wiv i i A INSPECTION NO. CITY . OF TUKWILA BUILDING DI�GI.. ION 6300 Southcenter Blvd., #100, Tukwila, WA'98188 RMIT NO. ,j, i (206) ..431 -3670 Project: ° Type of inspection: It Address: Date called: i.tz r5.s. q /r� Special instructions: Date wanted: a.m. g f iG � 4 0 p.m: Requester: C� Phone No.: Approved per applicable codes. 1 1 Corrections required prior to approval. Inspector: Date: U $42.00 REINSPECTION FEE REQUIRED. Prior to insf ection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ElitgelAVIN VAIMOStagg INSPECTION NO. CITY -OF TUKWILA BUILDING DIVISION 6300 Southcenter �Bfvd., #1 0 ;z Tukwila, WA 98188 67-07A 7 Project: Address: - Date called: Type of inspection: Special instructions Date wanted: a.m. 9/✓�� � p.m. Requester: Phone No.: . . Corrections required prior to approval. 90 w iv4ef t / /( GK AiU 6 \ I Date: t l`J / • $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Date: Project: I- I ee SI -?Sc Type of inspection: SO Address: 19258' - .SS A v . S Date called: 9 -/O -y g Special instructions: Date wanted: c� a.m. Requester: e Phone No.: COMMENTS: 6 1/14h .) N0.4 rye cry ID D, S. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECO Retain a copy with pe fl o T NO. 1 -3670 Corrections required prior to approval. Date: ri $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Inspector: Receipt No.: Date: f >' zF INSPECT! • ' NO. CITY OF :TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable: codes. CO MENTS: I Receipt No.; INSPECTION RVVD Retain a copy wi! , • rmit ..T.;n14 640 1,1:(14. Date: G PERMIT. NO, fir• (206) '431-3670 Project:. 5 .Address: ,Special instructions: Type of inspectic ,' Date called: Date wanted: a m:' Requester: Phone No.: Corrections required prior to approval. [l $42.00- - INSPECT! N V E REQUIRED. to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100., Call to schedule reinspection. Projeo54 S Type of inspe to : "Willigillat Ad1res5 3 .- s _ aj Date called: ( 1 Special instructions: Date wanted: 17 i P• Requester: IZer -� Phone No.: n Approved per applicable codes. INSPECTION RRD Retain a copy wik Dig'7.- on INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188(2(}64 1 -3.7 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: C J �1 Type of. inspection: di S .. Address: _ I Date called: / Special instructions: /l/ � j0 / •Date wanted: / Cd" a.m. p•m Requester: Phone No.: PERMIT NO. INSPECTION RRD Retain a copy wi rmit INSPECTION NO. CITY. OF TUKWILA BUILDING DIVISION 6300. Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. Inspector: Receipt No.: (206) 431 -3670 ,. Corrections required prior to approval. / $42.00 REINSPEC ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenterelvd., Suite 100. Call to schedule reinspection. Date: / Date: MINBratec INSPECTION R RD Retain copy wirrr►it INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION , 6300 Southcenter Blvd., #100; Tukwila, WA 9818E4,1 . Project: /, R Type of inspection: T Address: Date called: S �� Vii/ � � - --- Special. instructions: Date wanted: / �Z�a �a.�m.� v ,� Requester: � y / Phone No.: COMMENTS: ,?' Approved per applicablv .codes. Iai Corrections required priorto,approval. PERMIT NO. .Inspector: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: 6 Receipt No.: Date: Project^ J tF'a�Q i.3 Type of inspection: 5 Address: /� y . 5'$ SS � A ,S Date called: 6 - 5 Special instructions: Date wanted' 6 - /C 1 a.m. p.m.. Requester:_ Phone • No. .o & 4 /3I 5159 Approved per applicable codes. [Inspector: INSPECTION REC Retain a copy with D )nit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D97 - °a97 PERMIT NO. (206) Corrections required prior to approval. COMMENTS: 6 /44,ex km1 -2e Akfre/qc s y 6a-‘01.e. sp( 4 d hay /D - . , Ay/I- no - .r Abld Date: 6 / /4 / /ff $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: J • Approved per applicable codes. [Receipt No.: INSPECTION: R RD Retain a copy wi rmit INSPECTION NO. CITY;OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100,'" Tukwila, WA 98188 9 ) -6297 no At PERMIT NO. • (206) 431 -3670 Type of ' spec Date called: • • Date wanted: Prefect: Address: S— A i Special instructions: Requester: ft.) Lo ��efLeci ons _Sag ffteth Liorzto COMMENTS: approval. $42.00 REINSPECTION FEE REQUIRED: Prior to insaection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: Proje _5. g cry� Type of inspection: LA Address: I y 2,55 5 .. 4 .. AV c tr s Date called: a Special . instructions: Date wanted: /4 a.m. . . . p.m:' Requester: Phone No.: INSPECTI r NO. ' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 i Approved pef applicable codes. Inspector: INSPECTION RECD Retain ' a copy with nit I bq 7_p2 c( MIT NO. Corrections required prior to approval. COMMENTS: /N , /e -c.zES 5 '-v/v 1 x GAL) , f;uty S. Date: pw , $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: J Proje ct:.. S73'A) �ort�ST /tSn1 Type of • spe tion: A) . fr"CoT / !t/ Address:::. /2,5 — 5S A S Date called: : S .- 7(0 . Date wanted `) Special 'instructions: Z. cr .. 11 A H. Requester: 4124 ki ( vU-) Phone No.: ' p / PERMIT NO. INSPECTION R Retain a copy wi INSPECTI'N NO..: CITY' OF TUKWILA. BUILDING DIVISION 6300 Southcenter Blvd.,, #100, Tukwila, WA 9818 1 Receipt No.: Approved per applicable codes. (206) 431 -3670 Corrections required prior to approval. COMMENTS: $42.00 REINSPECTION FEE REQUIRED. Priorto inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Date: Project: - 're rs 0 h Type of inspection: . G (- aSt c te er . Address: zb6 5Sti, ,Ave S D ate cal le 12 - Special instructions:.. Date wanted: a.m. 1- . 13. - 9 � - p.m. Requester: L.ee S +e vis an Phone No.: 20(0/44 3 f �" 6_151 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300; Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: Approved per applicable codes. , Receipt No.: INSPECTION RECOR Retain a copy with per Date: D97 -0267 C _ PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION PUBLIC WORKS Pk\ e A-A-ck P6vs44+ ecoPt. &T v PLAN REVIEW / ROUTING�LIP LEE STENSON DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 2 -5 -98 COMPLETE NOT COMPLETE E NOT APPLICABLE COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE d NO FURTHER REVIEW REQUIRED Ei ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED ( l APPROVED W/ CONDITIONS NOT APPROVED (attach comments) 0 REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED 0 PE PREVENTION 0 STR Cb E DATE DATE D97 -0297 DATE 2 -4 -98 APPROVED W/ CONDITIONS 4 j NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE C:ROUTE -F G D $4 a COORDINATOR DUE DATE 2 -19 -98 • DUE DATE (Certifcat on of occupancy required. .: ; ei6 afGinKtWO.u'ul..rrvN.A I PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER PROJECT NAME LEE STENSON DEPARTMENT: BUILDING DIVISION 0 FIRE PREVENTION ❑ PLANNING DIVISION ❑ PUBLIC WORKS J STRUCTURAL ❑ PERMIT COORDINATOR ❑ DETERMINATION OF COMPLETENESS: (T,Th) APPROVED TUES /TBURS ROUTING: PLEASE ROUTE NO FURTHER REVIEW REQUIRE ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL REVIEWERS INITIAL NOT COMPLETE APPROVALS OR CORRECTIONS: (ten days) APPROVED W/ CONDITIONS ❑. NOT APPROVED (attach comments) ❑ CORRECTION DETERiYIINATION: APPROVED n APPROVED W/ CONDITIONS tl1nYAb7.'08hFA'roCMa4W�.s.aw++M naw,+ euw. �.... x. r.• �-•. �.. �..a.w.At.�VW'MAM +, 'IWWtd�Y�tYM DATE DATE D97 -0297 DATE 2 -4 -98 REVIEWERS INITIAL DATE DUE DATE 2 -5 -98 NOT APPLICABLE ❑ DUE DATE 2 -19 -98 ' DUE DATE NOT APPROVED (attach comments) ❑ (Certification of occupancy required. ) w.w4*.Gywimr.uoskiwit 47:v ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION PUBLIC WORKS REVIEWERS INITIAL APPROVED n REVIEWERS INITIAL L^ '1i�ENARf! PLAN REVIEW / ROUTING SLIP DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n NOT COMPLETE COMMENTS TUES /THURS ROUTING: PLEASE ROUTE [1 NO FURTHER REVIEW REQUIRE ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: APPROVED n APPROVED W/ CONDITIONS D97 -0297 DATE 2 -4 -98 LEE STENSON FIRE PREVENTION PLANNING DIVISION ❑ STRUCTURAL El PERMIT COORDINATOR 0 DATE DATE DUE DATE 2 -5 -98 °2/GA' DUE DATE 2 -19 -98 • APPROVED W/ CONDITIONS C NOT APPROVED (attach comments) t DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. REVIEWERS INITIAL DATE C:ROUTE -F PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0297 DATE 2 -4 -98 PROJECT NAME LEE STENSON DEPARTMENT: BUILDING DIVISION 7 FIRE PREVENTION El PUBLIC WORKS ► ! STRUCTURAL El DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE COMMENTS TUES /TUURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF REVIEWERS INITIAL (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) DUE DATE 2 -19 -98 APPROVED I r " I APPROVED W/ CONDITIONS 1 NOT APPROVED (attach comments) 17 REVIEWERS INITIAL /14 DATE 1 1 iqg CORRECTION DETERMINATION: APPROVED l l APPROVED W/ CONDITIONS DATE Z -��- -� (8 I NOT APPLICABLE El REVIEWERS INITIAL DATE C:ROUTE -F PLANNING DIVISION PERMIT COORDINATOR 0 DUE DATE 2 -5 -98 DUE DATE NOT APPROVED (attach comments) Q (Certification of occupancy required. ) .,ism./4: fr1L`ariMIV414 7CCI:Si +SSA. 5;2 5uCfi9;fit :5 iP6 t +r rxxx Naxravro1. SIV OspilintrOl*W4 BUILDING DIVISION PUBLIC WORKS REVIEWERS INITIAL PLAN REVIEW / ROUTING. SLIP ACTIVITY NUMBER D97 -0297 PROJECT NAME LEE STENSON DEPARTMENT: s L DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n NOT COMPLETE ❑ COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) APPROVED n CORRECTION DETERMINATION: APPROVED ' l 1 APPROVED W/ CONDITIONS C:ROUTE -F FIRE PREVENTION ❑ PLANNING DIVISION' 0 STRUCTURAL ❑ PERMIT COORDINATOR ❑ DATE DATE 2 -4 -98 DUE DATE 2 -5 -98 NOT APPLICABLE ❑ REVIEWERS INITIAL DATE DUE DATE 2 -19 -98 APPROVED W/ CONDITIONS , NOT APPROVED (attach comments) ❑ REVIEWERS INITIAL [I � DATE /o 2/ DUE DATE NOT APPROVED (attach comments) ❑ (Certification of occupancy requirtd. ACTIVITY NUMBER PROJECT NAME D PARTMENT: Irl B ILDING DIVISION ) WORKS CIS MW igo -1 REVIEWERS INITIAL C:ROUTE -F Pumi+ eoor4.Co'y PLAN REVIEW /ROUTING SLIP D97 -0297 CORRECTION DETERMINATION: APPROVED D STENSON CONST. — LOT B FIRE PREVENTION El C TVRA1 1 ❑ DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE Ei NOT COMPLETE COMMENTS DATE DATE 12/9/97 PLANNING DIVISION �n i ecl b ? -f -' 7 PERMIT COORDINATOR ■ DUEDATE 12/11/97 NOT APPLICABLE fl TUES /THURS ROUTING: PLEASE ROUTE LJ NO FURTHER REVIEW REQUIRED E] ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) 4 APPROVALS OR CORRECTIONS: (ten days) DUE DATE 12/25/97 '013 APPROVED APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) I)? tcn r rztrztZ - A•3. $ VIEWERS INDATE )41 DUE DATE APPROVED W/ CONDITIONS ID NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE (Certification of occupancy required, ACTIVITY NUMBER APPROVED REVIEWERS INITIAL C:ROUTE -F WPAI aiAltu, Gvat* i7A x.IVX: PLAN REVIEW / ROUTING SLIP D97 -0297 PROJECT NAME STENSON CONST. — LOT B DEPARTMENT: BUILDING DIVISION 111 FIRE PREVENTION [J PLANNING DIVISION d PUBLIC WORKS LJ STRUCTURAL El PERMIT COORDINATOR Q I DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE El NOT APPLICABLE 0 COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL Cam— DATE \ �� I I APPROVALS OR CORRECTIONS: (ten days) APPROVED El APPROVED W/ CONDITIONS REVIEWERS INITIAL DATE 2. l /0 I CORRECTION DETERMINATION: APPROVED W/ CONDITIONS DATE DATE 12/9/97 DUEDATE 12/11/97 , DUEDATE 12/25/97 ' NOT APPROVED (attach comments) ri DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) tiN'Ai.�l^Pf�i ".rM�3ff'i..1Y1 ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION El PUBLIC WORKS REVIEWERS INITIAL :Ge,c' '.i=Ci liRa 5aY"4it� "ihLe , s`Vis YtY1 PLAN REVIEW / ROUTING SLIP 0 D97 -0297 STENSON CONST. — LOT B FIRE PREVENTION LJ STRUCTURAL t 4 DETERMINATION OF COMPLETENESS: (T,Th) DUEDATE 12/11/97 COMPLETE NOT COMPLET NOT APPLICABLE a COMMENTS TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED I-1 ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL ..5 I I APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS El. NOT APPROVED (attach comments) El CORRECTION DETERMINATION: APPROVED El APPROVED WI CONDITIONS REVIEWERS INITIAL C:ROUTE -F DATE l"7/// DATE DATE DATE 12/9/97 PLANNING DIVISION 0 PERMIT COORDINATOR Q DUEDATE 12/25/97 DUE DATE NOT APPROVED (attach comments) 0 (Cerdfiadoa of occupancy required, ) ACTIVITY NUMBER D97 -0297 PROJECT NAME STENSON CONST. — LOT B DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE COMMENTS • APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS INITIAL C NOT COMPLETE El DATE PLAN REVIEW / ROUTING SLIP DATE 12/9/97 DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION n PLANNING DIVISION PUBLIC WORKS [J STRUCTURAL a PERMIT COORDINATOR 0 I DUEDATE 12/11/97 NOT APPLICABLE 0 TUES /TIIURS ROUTING: PLEASE ROUTE NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL ■J DATE / -L b I 1 DUEDATE 12/25/97 APPROVED n APPROVED W/ CONDITIONS ❑. NOT APPROVED (attach comments) DATE / Z(ig/�� t I DUE DATE APPROVED ' [] APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 (Certificadon of occupancy required. ) ? :ial.r??,'v:- ;kitf RECEWED DEC 3 0 1997 PLAN REVIEW / ROUTING SIAM W RKS ACTIVITY NUMBER D97 -0297 PROJECT NAME STENSON CONST. — LOT B DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION El PLANNING DIVISION d PUBLIC WORKS II STRUCTURAL PERMIT COORDINATOR 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n • NOT COMPLETE El NOT APPLICABLE rp COMMENTS ' TUES /THURS ROUTING: PLEASE ROUTE ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL C:ROUTE -F APPROVALS OR CORRECTIONS: (ten days) APPROVED ❑ APPROVED W/ CONDITIONS APPROVED ( l APPROVED W/ CONDITIONS ID DATE I�I t2) 7 REVIEWERS INITIAL DATE DATE 12/9/97 DUE DATE 12/11/97 NO FURTHER REVIEW REQUIRED El I DUE DATE 12/25/97 NOT APPROVED (attach comments) Q REVIEWERS INITIAL (lu DATE j:S0/ CORRECTION DETERMINATION: DUE DATE NOT APPROVED (attach comments) U (Certification of occupancy required. ) -! fist <,i!.�:rr�A7.�Were.r'r4rt.... x.>.r. ...... .. rv. w>.- a •+.. >n.�v.ver...rmw�t.as.rna..� r.rrru w..:wa�rw.....wx�ru.r> ACTIVITY NUMBER PROJECT NAME DEPARTMENT: LD IN DIVISION t i O'411 fog-\-ci IIB LIC WORKS REVIEWERS INITIAL C:ROUTE -F D97 -0297 STENSON CONSTRUCTION CO. LOT B FIRE PREVENTION p STRU �' ° /cri /Vi DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE U COMMENTS APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: APPROVED D APPROVED W/ CONDITIONS p ..... r .aw....r�..cu.r.�:.+w..n +�eralN wrXnrr+ r�r• wY .- .w�vi+nYtimvw.w.wYn1!xwrr��r! DATE REVIEWERS INITIAL DATE DUE DATE REVIEWERS INITIAL DATE C_ Ccor ct4vy C.py PLAN REVIEW / ROUTING SLIP 'rynbrntWx.rt+)i4f✓.n'N`. DATE 9 -29 -97 APPROVED El APPROVED WI CONDITIONS . NOT APPROVED (attach comments) DUE DATE 9 -30 -97 NOT APPLICABLE p PLANNING DIVISION PERMIT COORDINATOR Co( ( Mal I PC( tD -3 ( rzp TUES /THURS ROUTING: PLEASE ROUTE p NO FURTHER REVIEW REQUIRED 0 ROUTED BY STAFF [J (If routed by staff, make copy to master file & enter Sierra.) I 10 -14 -97 I DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) I DEPARTMENT: BUILDING DIVISION M PUBLIC WORKS REVIEWERS INITIAL APPROVED Ti REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F L PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0297 PROJECT NAME STENSON CONSTRUCTION CO. LOT B DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE COMPLETE COMMENT S P e r ► i i F C o (.t exc. TUES /THURS ROUTING: PLEASE ROU ROUTED BY STAFF l (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) CORRECTION. DETERMINATION: APPROVED APPROVED W/ CONDITIONS FIRE PREVENTION ' ! PLANNING DIVISION STRUCTURAL E PERMIT COORDINATOR DATE APPROVED W/ CONDITIONS DATE DATE DUE DATE 9 -30 -97 NOT APPLICABLE ri 6 ►1 Ca� c.rc4e. ) r� .it in( t4 �Q1I.? V NO FURTHER REVIEW REQUIRED E DUE DATE DATE 9 -29 -97 10 -14 -97 NOT APPROVED (attach comments) 1 DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) ,,s _ �`�� M1 ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION T PUBLIC WORKS COMPLETE n COMMENTS REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F L D97 -0297 DETERMINATION OF COMPLETENESS: (T,Th) (-66 APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMIr 1ATION: APPROVED ❑ APPROVED W/ CONDITIONS DATE DATE DATE PLAN REVIEW / ROUTING SLIP STENSON CONSTRUCTION CO. LOT B DUE DATE DATE 9 -29 -97 FIRE PREVENTION M PLANNING DIVISION E STRUCTURAL i l PERMIT COORDINATOR Q DUEDATE 9 -30 -97 NOT COMPLETE NOT APPLICABLE , TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED. ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) (Certification of occupancy required. 10 -14 -97 APPROVED I •I APPROVED W/ CONDITIONS I !. NOT APPROVED (attach comments) "1 DUE DATE NOT APPROVED (attach comments) in PLAN REVTF,W / ROUTING SLIP ACTIVITY NUMBER D97 -0297 PROJECT NAME STENSON CONSTRUCTION CO. LOT B DEPARTMENT: BUILDING DIVISION FIRE PREVENTION n PUBLIC WORKS n STRUCTURAL n DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE COMMENTS • APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS E. REVIEWERS INITIAL CORRECTION .DETERMINATION: APPROVED APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F DATE DATE DUE DATE. DATE 9 -29 -97 PLANNING DIVISION • si PERMIT COORDINATOR 0 DUE DATE 9 -30 -97 NOT COMPLETE E NOT APPLICABLE TUES /TUURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE 4 1 1 / 0 11/ I 10 -14 -97 NOT APPROVED (attach comments) E DUE DATE NOT APPROVED (attach comments) (Certification of occupancy required. ) COMMENTS REVIEWERS INrrIA% PLAN REVTE.W / ROUTING SLIP ACTIVITY NUMBER D97 -0297 PROJECT NAME • STENSON CONSTRUCTION CO. LOT B DEPARTMENT: BUILDING DIVISION FIRE PREVENTION I I PLANNING DIVISION PUBLIC WORKS STRUCTURAL DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE TUES /TIXURS ROUTING: PLEASE ROUTE )< NO FURTHER REVIEW REQUIRED E ROUTED BY STAFF f (4. routecrbrsia"tlyke copy to master file & enter Sierra.) APPROVED Fl APPROVED W/ CONDITIONS DATE APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS E REVIEWERS INITIAL DATE io(i / NOT APPLICABLE of'r DUE DATE t CORRECTION DETERMINATION: DUE DATE REVIEWERS INITIAL DATE C :ROUTE -F DATE 9 -29 -97 PERMIT COORDINATOR Q DUE DATE 9 -30 -97 10 -14 -97 NOT APPROVED (attach comments) NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) :'' �'" hCT. i'. ht: �txevw. a+ �..., �.«.....,.. .»..- .,...,..:.,..,- ...n;n+m. «. kn+.,. o,. w,« w�. a.. rr.. r. rw,... y+. a+.. n.... v..... mw-..... n... �.... w.. �..«,.... �.. w.....v,. .......nwr.� ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION fl PUBLIC WORKS ❑ COMPLETE n TUES /THURS ROUTING: PLEASE ROUTE El REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL C:ROUTE -F �exm* C�r6t Colpy PLAN REVIEW / ROUTING SLIP D97 -0297 CORRECTION DETERMINATION: STENSON CONSTRUCTION — LOT B DATE 9/09/97 FIRE PREVENTION ❑ PLANNING DIVISION 0 STRUCTURAL ❑ PERMIT COORDINATOR A 4 DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 9/11/97 rum NOT COMPLETE W NOT APPLICABLE ❑ ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.) DATE I I DATE REVIEWERS INITIAL DATE NO FURTHER REVIEW REQUIRED El DUE DATE 9/25/97 APPROVED ❑ APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ DUE DATE APPROVED l i APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Certification of occupancy required. ) .� : • ur nc isigge i:'�'•: .,���i�le to REVIEWERS INITIAL REVIEWERS INITIAL APPROVED D REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER 097 -0297 PROJECT NAME STENSON CONSTRUCTION — LOT B DEPARTMENT: Pl410414. 0461 a n BUILDING DIVISION El FIRE PREVENTION PLANNING DIVISION 0 PUBLIC WORKS STRUCTURAL El PERMIT COORDINATOR ❑ 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE [1 NOT COMPLETE COMMENTS TUES /T HUBS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF E] (If routed by staff, make copy to master file & enter Sierra.) I 3 APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: DATE 9//(/ APPROVED APPROVED W/ CONDITIONS ❑ . NOT APPROVED (attach comments) DATE APPROVED W/ CONDITIONS F NOT APPROVED (attach comments) 0 DATE Atto DATE 9/09/97 1 'I Z Sd 5 5 — . . 444V4 DUE DATE 9/11/97 NOT APPLICABLE DUE DATE 9/25/97 DUE DATE (Certification of occupancy required. ) ACTIVITY NUMBER PROJECT NAME STENSON CONSTRUCTION — LOT B DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION El PLANNING DIVISION 111 PUBLIC WORKS STRUCTURAL PERMIT COORDINATOR 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE fa COMMENTS TUES/THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE I APPROVALS OR CORRECTIONS: (ten days) APPROVED REVIEWERS INITIAL t awn CORRECTION DETERMINATION: APPROVED El APPROVED W/ CONDITIONS NOT APPROVED (attach comments) REVIEWERS INITIAL C:ROUTE-F ,;:e*mtAtem,sal, Mait:glarligitZ-VrAMAIMMIMIV D97-0297 PLAN REVIEW / ROUTING SLIP DATE 9/09/97 DUE DATE 9/11/97 NOT COMPLETE El NOT APPLICABLE Ei DUE DATE 9/25/97 APPROVED W/ CONDITIONS 111 NOT APPROVED (attach comments) DATE DATE DUE DATE (Certification of occupancy required. t . ' v.Am. i.'RiA $ 3c gatia�atgaat ilt;. n rV ++rg0.0;r:r. 0A"4ravAg efe• ACTIVITY NUMBER D97 -0297 PROJECT NAME STENSON CONSTRUCTION — LOT B DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION Q PLANNING DIVISION 0 PUBLIC WORKS II STRUCTURAL ❑ PERMIT COORDINATOR 0 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE El NOT COMPLETE / NOT APPLICABLE El COMMENTS 5 hot.() h Gr c� S 5 - tom UM G M & a Sed AA � .,L A, S /TUURS ROUTING: PLEASE ROUTE j NO FURTHER REVIEW REQUIRED a /N REVIEWERS INITIAL REVIEWERS INITIAL APPROVED U C:ROUTE -F PLAN REVIEW / ROUTING SLIP CORRECTION DETERMINATION: ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) DATE APPROVED n APPROVED WI CONDITIONS ❑ NOT APPROVED (attach comments) Q DATE REVIEWERS INITIAL DATE DATE 9/09/97 DUEDATE 9/11/97 DUE DATE 9/25/97 DUE DATE APPROVED W/ CONDITIONS IT] NOT APPROVED (attach comments) Q (Certification of occupancy requited. ) JJS/tkf Permit Center FROM Public Works Engineering DATE: V February 9, 1998 SUBJECT: Stenson New SFR NOTIFICATION OF UTILITY PERMIT ACTION 14258 - 55th Ave S (Lot B) Permit Number: D97-0297 Contact Person: Lee Stenson Phone: (206) 431-5159 Curb Cut/Access Sanitary Side Sewer Storm Drainage Land Altering 3/4" Permanent Water Meter CF: 4Development File (with copy of application and plans) PW Utilities Inspector (with copy of application and plans) Finance Department (with copy of application) John W. Rants, Mayor Ross A. Earnst, P. E, Director THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON FEBRUARY 9,1998: PERMIT FEE $25.00 20.00 25.00 76.50 260.00 TOTAL: $406.50 Two copies of the confirmed Utility Permit Application and plans are attached for inclusion in the permit file. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone.. (206) 433•0179 • Fax (206) 431•3665 j T r! - 1 - rel..14eC42-"si •- _ -1 1- 114 MIA ' T NibV4 rPl \/V•v-,9L`-< - f rm , 4450 0 1•14 1 1-111vire'• wA,L. tiopLi IAN ts -1195M- e=t4100- RECEIVED DEC 1 7 1997 u Kwi PUB -A LIC WORKS lageOltot 14 1 nr RECEIVED CITY OF TUKWILA f5X .44 1:)EC 1 7 1997 PE MI CENTER - •-• frZ sTay ocr — 'REM ERE!, AL TWOOD MOOS WASHINGTota • Dear Ms. Spencer, The revised estimate of material House eHcavatior Rear step out Driveway eucauation Total cubit feet •-• LEE STENSON CONSTRUCTION; INC. 144 S.' W..1531111 SUITE C . '-.IIURIEN, WIISHIN6TON 98166 286-431-5159 FIN 286- 431-1224 December 16, 1997 Ms. Joanna Spencer Development Engineer City Tukwila 6309 Southcenter Blvd, Suite 100 Tukwila, Washington 98188 cirl RE: 1197-12er - 14258 55th Rue. So., Tukwila, Washington or 336 yards of material to be moved from the site. If you have any questions please do not hesitate to contact me. Sincerely, F. LEE STENSON CONSTRUCTION, INC. FLS/tim F. Lee Stenson President to be moved off site is as follows: 26 25'H2'H8 = 400' 16'1120145' =1,600' 9,904 RECEIVED DEC 1 7 1997 UBLIC p TUKWILA W° RKS RECEIVED CITY OF TUKWILA DEC 17 1997 PERMIT CENTER Project Name/Tenant: Value of Construction: Is this site served by: ® Sewer ❑ Septic (King County Health Dept. approval required - 296 -4722) Address: ' u 4 ► V City State /Zip: Site t.J� S h Tax Parcel Number: 31f S9n- (11f17 f4 - z� r - 3Z'a -- �i`._ T71kwi1a Wa 9R1RR Property Owner: F. LEE STENSON CONSTRUCTION, TNf.. Phone: 131 -SLS9 , Street Address: City State /Zip: 144 S. W. 153rd Suite C. Burien. Wa 98166 Fax #: 431 -1224 ' Contractor: F. LEE STENSON CONSTRUCTION. INC. Phone: 411 -5159 Street Address: City State/Zip: 144 S. W. 153rd Suite C. Burien Wa 9Rlhh Fax #: /111 - 172A Architect: Dongald Atwood Phone: 935 -2712 Street Address: City State /Zip: 4316. 30th Ave. S.W.. Seattle- Wa 98126 Fax #: qr1 Engineer: Phone: Street Address: City State/Zip: Fax #: Contact Person: F. Leon 'ensnn Phone: / 131 5159 Street Address:. City State/Zip: 144 s w 1 S'Arr1 C„it. r u.... -. ..., T _ 981 AA Fax #: i. 11 /A Description of work to be done: New construction single family residencew COf1StfOC-f of RocKery Type of work: New Single- Family Residence ❑ Addition - Single - Family Residence • Interior Remodel- Single - Family Residence ❑ Residential Accessory Structure' ❑ Remodel /Addition to Accessory Structure ❑ Garage(s) ❑ Deck(s) - Covered & Uncovered ❑ Residential Reroof Is this site served by: ® Sewer ❑ Septic (King County Health Dept. approval required - 296 -4722) Existing Square Footage for Structure: sq. ft. Dwelling sq. ft. Covered Deck(s) sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck Proposed New Square Footage: 2 , 078 sq. ft. Dwelling sq. ft. Covered Deck(s) 488 sq. ft. Garage /Carport sq. ft. Accessory Structure(s) 432 9.�t. . n Deck B Floor Area Ratio: (total floor area of all structures divided by the area of the lot) *For an Accessory dwelling, provide the following: Lot area Floor area of principal dwelling Floor area of accessory dwelling • Provide documentation that shows the principal owner lives in one of the dwellings as his or her primary residence. CITY OF T KWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 JOB 709 . ....... • Project Numbers ;.Permit Number: Single - Family Residential Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST :FOR PUBLIC .WORKS;SITE /CIVILPLAN.REVIEW OF THE FOLLOWING : (Additional reviews. shall be deterrfined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Hauling ❑ Land Altering: 0 Cut cubic yds. 0 Fill cubic yds. ❑ Moving an Oversized Load: Start Time: ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage '❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous End Time: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be re- viewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall ex- pire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: (3 R; Application k; by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM SFPEP.MIT.DOC 2/13/97 ALL SINGLE- FAMILY RESIDENTI • ERMIT APPLICATIONS MUST BE .:MITTED WITH THE FOLLOWING: ➢ DRAWINGS PREPARED BY ti( GISTERED ARCHITECT OR PROF; ZONAL ENGINEER MAY BE REQUIRED BY THE BUILDING`OFFICIAL ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Copy of recorded Legal Description from King County ❑ ❑ Certificate of water /fire flow availability (Form H -11 a), Contact the Public Works Department (206) 433 -0179 for servicing district. ❑ ❑ Certificate of sewer availability (Form H -11). Contact the Public Works Department (206) 433- 0179 for servicing district. ❑ ❑ Metro: Residential Sewer Certification (if Tukwila Sewer District) (Form H -12) ❑ ❑ King County Health Department approval for septic - 296 -4722 Four (4) sets of working drawings, which include: ❑ ❑ Site Plan (see example Form H -16) 1. Existing fire hydrant location(s). 2. Proposed access road. 3. Driveway location- driveway shall be 10' wide minimum and 20' wide maximum. If driveway is over 150' long, driveway shall be 20' wide and have an approved turnaround (City Ordinance 1741). 4. North arrow and scale. 5. Building setback from property lines. Any proposed or existing easements must be shown on plan. 6. Public Works review requires the following on site plan: driveway location (10' min., 20' max. width), show proposed and existing power, water and sewer lines, existing storm drainage system, downspouts and foundation drains, and where drains tie -in. 7. Parking plan. 8. Lowest building elevation (if in Flood Control Zone). 9. Estimated /proposed topography at 2' intervals and proposed elevation of lowest floor level. 10. Identify location of sensitive areas slopes 20% or greater, wetlands, watercourses and their buffers. 11. Identify location and size of significant trees that are located in sensitive areas and buffers or the shoreline zone. Of those, identify which are to be removed (Title 18, City of Tukwila Zoning Code). 12. Identify location of high water mark of the Green /Duwamish River if site is located within 200' of the high water mark. 13. See Public Works Checklist for detailed site plan information required for Public Works Review (Form H -9). ❑ ❑ Foundation plan and details • ❑ ❑ Floor plan ❑ ❑ Roof plan ❑ ❑ Building elevations (all views) ❑ ❑ Building height ❑ ❑ Building cross - section ❑ ❑ Structural framing plans and details necessary to completely describe construction ❑ ❑ Washington State Energy Code Data (Gas /Electric /Oil /Propane /Heat Pump) Form H -15 available at Permit Center OR Prescriptive Heating System Sizing Chap 9 Form H -6. ❑ ❑ Complete Land Use Applications if not previously submitted (i.e., Reasonable Use Exception, Variance, Shoreline or Tree Permit). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance and other land use or SEPA decisions. ❑ ❑ If dwelling has a septic tank, and a bedroom or bathroom are added, provide written approval from the King County Health Department or the Tukwila Public Works Department prior to submittal of permit application. ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent. If the applicant is other than the owner, registered , architect/enginaei or contractor licensed by the State of Washington, .a notarized letter from the property owner authorizing the'agent to submit this permit application: and obtain the permit will be required as part of this submittal. s,r. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU HORIZED AGENT: Signature: � Printp STN SON, PRESIDENT Address: 144 S. W. 153rd Suite C SI'PERMIT.DOC 2/13/97 Date: 9/9/97 Phone: 431-5159 Fax #: 431 -1224 City /State /Zip: B u r i e n, Wa. 98166 SHEET NUMBER(S) SUBMITTED TO: CITY OF TUKWILA Department of Community Developm ent Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL DATE: 27 / PLAN CHECK/PERMIT NUMBER: 9 7 9 7 PROJECT NAME: sC 7t 5 OIL/ PROJECT ADDRESS: Z S S '] CONTACT PERSON: PHONE: °' 1 .7'3 REVISION SUMMARY: /2 F, Or ' h '9 / f PA A At "Cloud" or highlight all areas of revisions and date revisions. CITY USE ONLY RFCIFIVFD CITY OF TUKWILA FEB 0if1998 PERMIT CENTER 3/19/96 February 3, 1998 Mr.. F. Lee Stenson 144 Southwest 153rd Street, Suite C Burien, Washington 98166 Dear Mr. Stenson: SUBJECT: CORRECTION LETTER #2 Development Permit Application Number D97 -0297 Stenson Construction - Lot B 14258 55 Av S This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Planning Division, At this time the Building Division, Public Works Department and the Fire Department have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sinc9 rely, , CGe Kelcie J. Peterson Permit Coordinator Enclosures File: D97 -0297 City of Tukwila Department of Community Development Steve Lancaster, Director John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 ■ 01: 141 oh '\1,1�r� City of Tukwila John W Rants, Mayor ,k by��.== Department of Community Development Steve Lancaster; Director 1908 PLANNING DIVISION COMMENTS - .Dq 1 o& q �] D ate December 18, 1997 Planner: Michael Jenkins Tele: 431 -3670 If you have any questions, please contact me at the phone number listed above. The front yard and rear yard setbacks on the Site Plan are incorrectly listed at 24 feet and 12 feet. The correct measurements, based on Plan scale, are 20 feet and 16 feet. Please revise. The plan indicates a 550 cubic yard excavation. If this amount is correct, a SEPA checklist is required, as the SEPA threshold is movement of 500 cubic yards of earth or more. Please revise if this information is incorrect :or submit a SEPA checklist. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 December 16, 1997 F.•.LEE STENSON CONSTRUCTION, INC.:: 144 S W. 153110 SUITE C '8URIEN„ WRSHINISTON 98166 286-431-5159 F1111 286- 431-1224 7. RE: 1197-8211? - 14258 55th Rue. So • Tukwila, Washington House micauation Rear step out Driueway eHcauation Total cubit feet or 336 yards of material to be moved from the site. If you have any questions please do not hesitate to contact me. Sincerely, F. LEE STENSON CONSTRUCTION, INC. IFLS/tim Lee Stenson President 26' H38' H8'=7,904' 25 = 400' 16 =1,600' 9,904 TUKWILA PUBLIC WORKS RECEIVED CI TV YRECE C W I L A • DEC 11 1997 DEC .7 199 PERMIT CENTER Bldg. 'I$EVISIGN g REV/ SE /' CITY OF TUKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL ,DATE: �� ci 19 PLAN CHECK/PERMIT NUMBER: Dc11-0acil PROJECT NAME: 3 C et - EN PROJECT ADDRESS: mass • 55 AV S • 9NTAGtPER.01i: Lem L eo- 7e SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: e '� CITY USE ONLY Planning �= 077D%ti ` /SJ 9 4er5 Fire ' , PHONE: 1 4 ?') l -- 5t 9 Public Works RECEIVED CITY OF TUKWILA DEC 0 9 1997 PERMIT CENTER 3/19/96 JOB 709 C Lot B Short Plat No. SP90 -5 -55 WATER METER BILL OF SALE vs.w W,Se vwnvvw+:+r+wa mwmtrelw�rA .etts+.rru+iht�wr +k+r; ,rtfl 7- 0 KNOW ALL PERSONS BY THESE PRESENTS, That F. LEE STENSON CONSTRUCTION, INC. a gezeratmpartnewsktpOcorporation and existing by virtue of the laws of the State of WASHINGTON , and doing business in the State of Washington located at144 SW 153rd Suite C , City of BURIEN , in KING County, for and in consideration of the sum of ten dollars ($10.00) lawful money of the United States, to it in hand paid, the receipt whereof is hereby acknowledged, does by these presents grant, bargain, sell property , located at 14258 55th Ave. So. , , City of Tukwila, county of King, State of Washington, to wit: ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** LEGAL DESCRIPTION OF PROPERTY: ********************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** LIST OF MATERIALS /ASSET DESCRIPTION (Number of) 1 water meter box(es) (located at the above address) and (number of) 1 linear feet of (size) 3/4 -inch meter service line(s), with appurtenances, made of (type) k- copper material, with an installation cost of $ 52.50 , constitutes the list of materials for this turnover. ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** The seller herein covenants, agrees and warrants that it is the owner of said property and that the same is free from all liens and encumbrances and that it will defend the sale of said property, goods, and chattels, hereby made, against all and every person or persons whomsoever, lawfully claiming the same or any part thereof. EXECUTED at (City) Burien this 8th day of December 1998. SELLER: BY: B3'iI`. -'hie Stenson TITLE: President TITLE: , Washington, *******•************************* A*********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** STATE OF WASHINGTON County of: On this day personally appeared before me F. Lee Stenson to me known to be the individual described in and who executed the within and foregoing instrument, and acknowledged that he signed the same as a free and voluntary act and deed, for the uses and purposes therein mentioned. GIVEN under my hand and official seal this 8th day of December 1998 . Notary Public in and for the State of Washington, residing at 3232 So. 256th St., Kent, Wash My appointment expires 3/28/01 MARY E. HEINE STATE OF WASHINGTON NOTARY - -o -- PUBLIC YY CODUISSIOR EXPIRES 3 -28 -01 October 31,1997 Mr. F. Lee Stenson F. Lee Stenson Construction 144 Southwest 153rd, Suite C Burien, Washington 98166 Dear Mr. Stenson: SUBJECT: CORRECTION LETTER #1 Development Permit Application Number D97 -0297 Stenson Construction - Lot B 14258 55 Av S This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Building Division and the Public Works Department. At this time the Fire Department and Planning Division have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, � /, ec .1 t /r) Kelcie J. Peferson Permit Coordinator Enclosures File: D97 -0297 City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 T OJECT NAME: PPLICATION NO: PLAN REVIEWER: BUILDING DIVISION REVIEW Ken Nelsen, Plans Examiner (206) 431-3670 Oct. 9, 1997 Stenson Construction, new house lot "B" D97-0297 Please provide specific engineered plan details for the retaining walls that will contain the earth directly outside of the proposed garage entry . • • City of Tukwila ... _1:1.[YeM>••(y1x•Yf Y•.' �Al. rtylP.:^ q .?I: }ry�.,gH•vw...H! +.�'�ttr.+s Department of Public Works Ross A. Earnst, P. E., Director PUBLIC WORKS DEPARTMENT COMMENTS DATE: October 21, 1997 PROJECT NAME: tenson Construction SFR PERMIT NO.: D97 -0297 PLAN REVIEWER: Contact Joanna Spencer at (206) 433 -0179, if you have any questions regarding the following comments. 1) Provide an estimate of cut and fill (cubic yards) and quantity of land to be cleared (square feet) for land altering considerations. If more than 50 cubic yards is to be imported to or exported from the site, a hauling permit will be required. 2) Label the existing 8" sanitary sewer main located in 55th Avenue South on the plans. The label shall read: "Existing 8" sanitary sewer main." Is there an existing sewer stub? If there is, please state on plans. If not, a 6" sanitary side sewer with test tee and cleanout shall be brought to the property line. The section from the property line to the new single family residence shall be a 4" sanitary side sewer pipe. Specify the type of pipe, size of pipe, and slope of pipe for the sanitary sewer line. Type of bedding and backfill material, including percent compaction, shall also be included. See attached Public Works standards. 3) Specify type, size, and location of proposed water service line and size, and location of proposed permanent water meter. 4) A detail showing how the existing rockery will be connected to the proposed retaining wall must be shown on the plans. The storm drainage system that will be installed behind the proposed retaining wall shall also be shown. These details shall be approved by your geotechnical engineer prior to submittal. 5) The David Evans geotechnical report dated August 1997 does not bear the stamp and signature of the geotechnical engineer. These items must be included in the geotechnical report. . ' i . 'Rn'!'i�'Miw4M'Y}N'^Y'•:1 1 9M.: 6) If the storm drain line is to be constructed under the sidewalk, two structures will be required at the bends. Public Works recommends placement of the storm drainage line in the roadway and installing only one catch basin at the bend in the storm drainage line south of the proposed driveway. The size of the proposed storm drainage line shall John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433.0179 • Fax (206) 431 - 3665 match the size of the exis g storm drainage pipe that lies be en the two existing catch basins on 55th Avenue South. , Pipe material for the storm drainage line shall be concrete or ADS-N12. Please note that th new storm drainage line will become part of the public storm drainage system. Prior final inspection, turnover documentation shall be provided to the City along with a request for turnover of the constructed public facilities. These proposed public facilities will be accepted through the City Council or the Mayor's Office only. If the Public facilities are not accepted, they will remain the sole property and maintenance responsibility of the developer. It is the responsibility of the developer to provide the necessary docun to allow consideration for such turnover through the City's elected officials. REVISION SUBMITTAL DATE: 9 CITY OF TUKWILA 14? Department of Community Development RECEIVED Building Division - Permit Center CITY OF TUKWILA 6300 Southcenter Boulevard, Tukwila, WA 98188 S E P 2 6 1997 Telephone: (206) 431 -3670 ,2_61/9 PROJECT NAME: . - c) PROJECT ADDRESS: / ( 5 `7 3 5 / V CONTACT PERSON: '< r S"77 SPHO IE: 3 / `S 7S REVISION SUMMARY: A AmLc:,6) 0 77% /7 O 4,/ .S / 1E D/ S< '/ A e U/ c.64 SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: CITY USE ONLY Bldg. Planning Fire PERMIT CENTER (its I�7� I) 0 1 PLAN CHECK/PERMIT NUMBER: �/) 7 T Xil f-Ol /RA, Public Works 3/19/96 September 12, 1997 Mr. F. Lee Stepson 144 Southwest 153rd Street, Suite C Burien, Washington 98166 Dear Mr. Stenson: SUBJECT: LETTER OF INCOMPLETE APPLICATION Development Permit Application Number D97 -0282 Stenson Construction - Lot B 14258 55 Av S Sincerely, 7eee.e. -19; -19;ite 502 Kelcie J. Peterson Permit Coordinator Enclosures File: D97 -0282 City of Tukwila Building Division: Contact Joanna Spencer, Development Engineer, at 433 -0179 if you have any questions regarding the following comments. 1. Please show on your site plan all utility lines and all drainage for carport downspouts. See Public Works Checklist H -9 (enclosed). John W. Rants, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 27, 1997 was determined to be incomplete. Before your permit application can begin the plan review process the following requirements from the Public Works Department must be met. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation please submit four (4) copies of each document. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431- 3672. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 431.3665 Poses( FAx Note 7071 • ,,?. q ] ► / ' h a r d E Al u r *w 4 )21q4 tie n u( G `".'L!J I 4'n � Cu. Phnne s 2.04A ( voz) P 7 03.3 7 F `,Q4 4 - "7,2"9.3 Fri s 2e)3,3719 tli tab ■ tN .. ;.t 0 -..., P BY: . Au . 31 1" 1"'10 (Rev. Dates Jit 9. 1990 (29/PLkT.MAP) • 27 -97 ;10:35AM ; NF' A l's Rtmovs -I A.Rom ;.•r.rfii•rl 4 IKst lwry 4 c,sr, 4rua► i ifrOriv•wAy AG►se+ t. } Dkal•A }' 41ty or Tukwilrt Fir Ks i4 ( :e, *140M twiH11U a' ► �✓ .w . , / irt.eMw thrrt r / „we 311345 Sr t J2:. Fi ` ! 1) I API 1 ¢.1 tIn \\144T1.1 T 13\ \. - .\t \ it \ I E MOTU. 1. asotaobnioai /bydrolo9iosl.report by Washington State licensed Engineer for City review and epps;oval for wee and construction on tercel A • shall s000rpeny any building permit.. 2. A Structural Engineer is to analyse the remaining rookery to assure that it (remaining rockery) I. Stable. 3. Driveway devsiopuent of Parcel s requires a Daylight- basement dosage. 4. Mem wu cwita (single•" Psmily i Land Surveyor's Certificates This Short Plat correctly represents a survey made by ma or under my direction Las conformance with the requirements of appropriate state statute rind has been properly staked. b1'A8't0" V 0 loos -0$t Certificate NO. 9690 short Plat No. •+S .SS Direction; Scale: 1" • 30' 206 244 7593 4 1/ 1 o 4 k, RECEIVED DEC 0 71990 1• UKWIL A PUBLIC WORKS ^ PbRT1oN ‘A./ $4- t3PI. -R.4 L. Map on riii in vault • — ` r .&kery ( Page ol • _ of 4/ 09/97 ION FAX',2550286:: • • . .. • • ., • •-• aillft4MOMMMUOINIMMOOMMIBMWMOM = ‘1111401.111■=2111111M=24!Malll „ . METROSCAN PROPERTY PROFILE KING COTJNTY • • • • • „ • ..', • . . • • • ..' •• • • EXPANDED LEGAL DESCRIPTION • n ammormwomm = •asse•••• ir nnnnn limmimmism nn rormarir nnnn mem n rImmilmaromforrer= n r • ramr.irm= Parcel*:336590 03.07 Sit() Address:*No Site Address* Tukwila mmm BLK 2 LOT 1-2 HILLMANS SEATTLE GARDEN TRS POR OF LOTS 1 & 2 BEG SW CORNER OF LOT 1 TH N 01-20-40 E 13 FT TO POB TH N 01-20-40 E 101 PT TH S 88-48-20 E 70 FT TH S 01-20-40 W 108 FT TAP 6 FT NLY OF 8 LN OF LOT 1 TH N 83-05-37 W .70.33 FT TO POB -- AKA LOT 8 OP CITY OF TUICWILA SHORT PLAT NO 90-5-55 RECORDING NO 9101071307 RECEIVED OitY OF TuKwitA SEP 0 9 1997 PERMIT CENTER • REGISTRATION NUMBER • FLEESI.*122CA 01/25/1999i' EFFECTIVE ,DATE 1 02/01/1988: :‘ r. F LEE STENSON INC: . . • .:••• 144 SW 153RD STE C BURIEN WA 98166 INTRODUCTION In August I997.1 Evans and Associates, Inc. (DEA) completed a geotechnical study for. lot loca.d at the corner of I.th Street and 55th Street, in Tukwila, Washington. This report present the results of our geotechnical study and is mt.. as part of the requirements for buik.g permit application rad fotmdation design. The approximate project location is shown on the attached Vicinity Map, Ng. I. The purpose of our work was to evaluate the amditions of the site, inspect. amdition of an existing rockery and provide recommendations for foundation design and con.ruction of. proposed residence...two& inched. a visual recommissance of the area, and research of available information Access to the site . limited at... and therefore no subsurface evaluation was performoi The information gathered from the an.ysis was utilized Os develop the geo.chnical recommendations. Proposed Development We understand .t the new construction will include a single family residence which .hales a daylight basement md two additional levels of wood .ne consthation. T. home v. fitce west with a new driveway through the roclmy near tile northwest comer. It is our undemanding that the rockery will be removed in the northwest comer of the and replaced with nvo cones. walls to provide an access .m s.et level on t. west side. The remainder of the rock, .1 remain in place. fil=5:11g1211DNa The property is located on the northeast comer of the intersection of 55th AVM= South and 144th Street So.. There are two lots known as Parcel A a. Parcel B. Than is lat exist. reside.= on Parcel A, which is not included in this pmject. Pamel B is vacant at this time. The topography of the site within the building area slopes generally to the west toward 55th Avenue S. OuMde of the lot boundary below the base of the rock,, topography slopes to the southwest toward the Mtersectiort T h e m i a l =lief along. top or I r l e m me lot is approximately 10 f e e t f r o m the east property line to the west rine. The slopes above the top of the rock, do na exceed 25%. Based upon the slope of the lot a.ve the top of the rockery, the lot appears to be classified as a Class 2 area of Potential Geologic Instability, according to the City of Tukwila Sensitive Areas Overlay Chapter 1845. T. slope of the lot is .tween 20% and 40% and the site is underlain by te.tively permeable soils, as per the definition. The rockery is a man made cut into the slope and the house will be setback a sufficient distance from the top edge of the rockery. The exis rockery extends from the northwest comer of the property, south, to the southwest comer. The total length along the west .de is slightly over 100 feet The north end of the rock .1 is approMnately 6 feet high and the south end is approximately 10 feet high. The north end of this section will be removed to pmvide access to P m c e l B. The rock, toms to the ea. from the southwest corner and emends approx.a.ly 120 feet to the east At the southwest comer the rockery is approximately 10 feet high. The roc.ry tapers down in height to the east. a height of 3 feet .spection of the rockery was made Mth the following observations: • The maximum height of the rockery is 10 feet . • Ile ..snum height of the rockery 3 feet • The rock used in construction appears to be of sound quality • The rock used in construction appears to be of appropriate sim for the height of the rockery. • The batter of the rockery appears to be approximately IH:6V. • The toe of the rock, is keyed into the base of the slope. Along the south property line ...calk. poured up against the toe of the rockery • T.re appears to be a perforated pipe e.ting along the toe of the rock, at the south west comer of the for drainage from behind the rockery • The rock, appears to . backfilled with coarse quarry rock for drainage • There are numerous other rockerim . the vicinity which are built into adjacent slopes which appear to be mable at tths time. • T. te),,,,hy of the area indimtes .thhe rockery . placed against a cut slope. - Based upon the observations made it is our opinion that the rockery is stable in its present condition. We recommend that for the future stabilityof the rockery a no load rune be established back from the top of the rockery. We also recommend t.t all dminage from the proposed development be captured and diverted away from the top of the rockery. No uncontrolled runoff should be allowed to infiltrate behind the rockery. DISCUSSION AND RECOMMENDA1TONS Slope Stability Our assessment of the site, included visual observations of the surface conditions and the sunounding area. In general tbe site appears to be in a stable condition, with no evidence of.. soil movement or deep-seated sliding. The vegetation in the area also gives no indication of past instability. Seism. Considerations The si. is considered to be a 2one 3 c.sification as per the Uniform Building Code (UBC). According to Table 234 of the UDC the soils on the site should he classified as S3. Site Preparation gXgEJ The vegetated areas should be stripped and grubbed prior to the placement of any fill or foundations. T. topsoil and vegetation should be removed from the site or may be stockpiled and used in lan.caped areas. It is anticipated that the sMpping depth to remove the vegetation will be 8 to 10 inches. There shall be no organic material included within possible fill areas placed for the raising grade under foundation areas. We recomme. that dur.g the excamtion the basement, the cut should be sloped back at IH:IV to preserve the stability of the slope. Slopes that are to be left permanent should not exceed 211:1V, and should. revegetated as soon as possible. 2 Oc1 It is recommended that all compaction done .hind . retaining wath be compacted Mth hand equipment such as a vibrating plate orproping jack. The use °flame equipment. induce stresses the wall which may exceed the dexige- Foundation Support If. footings are phced upon . dense native mils, on allowable bearing capmity of 2000 mitre, be utilised. We TeCOinnlend that wt.:mums foo.gs have a minimum width of 16 .chrs and individual footings a minimum width of 24 indica. AU cues. footings shall . placed a minimum 18 .ches below fmished grade. A on.third increase in allowable bearing capacity may be utilized for short Mm loads such as the ease of a se.. event or wind loading, qualified so. engineer should inspect all foo.g excavations prior to concrete placement. assure bearing capaciry and the cond.. of. excavation. Saha. Shb-On.Grade Retaining S... For tire drasign of:raining walls or extended stem walls a fluid equivalent pressure of 35 pcf may ..sumed if the wan is allowed to yield on amcomt equal to 0.001 times . height Walls that are not allowed to yield shall be designed to Md.. fluid equivalent pressures of 50 pet Walls backfined at the base with native so. may resiat 250 peg loran equivalmt pass.e.sistance and a .35 coefficient of friction may . used for slid.g. The pressures given allow thr short term lesithng during a Ii 100year seismic event The p.n.s given assume a drained condilion with no ...ter haul.. and level irtrkfill thickness of 12 inches of free draiMng material is required behin, the w.l. The soil shall be a free thaMing material with a maximmu of 5% pas.ng the 6200 Standard Sim= of similar to the specification for struc.al The soil shall be ph.. maximum 12 inch tins and compacted to 90% of rna.mum dry density, as per ASINI D- 1557 Modified Proctor Method. The 12 inch drain layer .11 . backed by a fabric and . remainder of the backfill may . the native son. The only steep slopes orrthe property are those associated with the rockery arm. the perimeter of the site. In order to presenre the stability of the rock,. recommend t.t an adequate .tback be maintained from the top of the rockery. Asedsack fr.. back side of t. rockery equal to t. height of the rockery, plus 5 feet, should be maim.. for all load bear. structures. For. placement of a slab-on grade we recommend that the subgrade sons be free of orgaMcs and a finn and unyiekling condition. We recommmd that the floor slab be underla. by a m.mum of 4 inchm of clean sand and gravel, washed rock rupee matvei to serve as a capillary break. An impervious moisture baMer rhoukl also be placed bmeath the slab. Drainage Footing.. should be p.c. along the out.. of perimeter .tings. The drain sbnild consist of. 4 ioch perfomtedPVCpips placed Ina. of. graveL The perforated drain .es aball that. datelined intn the moor collection system. All roof.. shall be also be tightfisted and nm sepandelyfrom the footing drains to the storm water collection system, or to the.' of the slope to thew.. SXMAISQN Inconel... faith. tiler:ripe. eons.etion oanpatible meet. misthig conditions...loot jeer.= . stability of the area ff the foregoing recommendations ara on.. with. We rosommmd.tDEA. ra...oughoutilla mojeot to assure compliance with. specifications. I TINTTATTON The Informal...Med in this analysis hu been prepared using generally accepted geologic and engineering practices in use att. time of our investiption. The use of Warm. for the proposed develop...sums no warmly expressed or implied fort. geologic rad son conditimut described. The information presmted is applicable to the subject property only, md should not be applied to the adJacent It expected that the o.site conditions will reflect our finding; however, tame variations may occur. Should conditions beam... that cause conc. andkrarenot as discussed basin, DEA should be contacted thremunrine the conditions enemmtered with regard to . posposed development DBA would Ithe to thank yon for the opportunity to misty...et Mdt this geologic assessment If there are any Rather questions mprding the information present4 Om< sow. us at (206)9224780. Sincerely, DAVID EVANS AND ASSOCIATES, PIC. Matthew A. Miller, P.P. Gmlogical Engineer mahraretraOkk eetiattatosihakeeerat los... VIII CS 4 444_ A/./E 77.1-I I r-tzr 1 --1 7 1 7 - jr4oet.- W/ AT ,Y-A-101,5. r y I W11-4 W1 1-4 7 — Gf-1-49 , TSF- err G1-.1 I,/ avq t - F 1, 1 - - ,zritlAolz - 7M' - • - 414 W.-7e , z-I°Z frn I-I > 11 . 4, - - - 4:42 r47- = Iota' '0- rt I 40,A51:70k.4 •;•1: 74.0 7p,35,4 1.4„av &e: tyrif4 pr.cr=. sebi „,r 110 - - 8 7 7 - 7'E 4, FLf,ric- -- F.04 1.7e V 9 5 vets - r., 1 ‹ 245 g -ti r —r. \Fr --1--- - 0-- --- s -_ z„ These plans have been reviewed by the Public Works Dc-r for conforms -S current City stan-O - Os. Acceptance L. orrers anS - which do not aulfr &los! 17 .:r or ordinances. -.- for th: adequacy of the design r • .1 the designer. Additions, deletions Cr these dra Wings after this date acceptance and will require a ressl of revised drawings for subsequect app.c ;Ed. Final --,lance is subject to field inspection by the Fiihc Works utilities inspector. Date: /0/ fe By' 71 c74 _55 5 5D lif)H (e `t1 11, •L■rlatee ass 5 CITY OF Wil7 p,pPROVED 1 1 1998 Eta? DIVISION (-22- -N31-02.91_ _ _ L41-47 - 1 hiri%', aN. II L743. ii--uur - 1.44- 1 ks 5 4114 W11- _ _ AN17' ritsG 1-1 57 I v-0 - 4-516, 1 _,6•At , 4,219Z • FEB Bk199 PERMIT CENTER REGIST oriiti it. 7' li • ‘} - 4 1, ,a-7 • 1l-t•T P; ` U k_ VV I . LA . _IP- C ciTYAE E y ,,4 DEC'09 1997; PR R O V D FEB 1 1 5998 b - C r' '• 1i 0 -0-' "h. I r - - 4 -r.ii ' ----11 4.1,x C -,5.+ (W9 -t' 41iz —TATf t r -= -r- Q4µ'[ 4�Z`tF1�F L4 l 141 re t ATE= , = Coo Yh+ (AIM A645 GtAOE 40) r!o 5,,c17..7e - p Of F EB 1 1 1998 1. 3s pa g y,` 1. 1 pass p � 35 ?Cr 4 t = Il2d 4 4,10° 1 V - I vi ea. imik : 4:x 15oxb -- 51,1) . I If q33 lb. f÷ f•11: 5. VixI7ogx5' 3 4' 'ii,9YY i6.ff = 3,G1.3 lb r.Tf: 5I7x ISelef c t� aif - 1,1,461614 z = &qc[b — ii,31S 164f , i. oTM tai Q 1`oy _ gdoo - t0,245. ILL t✓1 ta % o a 8, � Z ` -2 = 6.2$ Ni - 4,1 &e a - 31,i3o !bl^ A + 3: y 9 zo + got f i s ts Psi cI n /� pp 01.412 /7. xF'• -- Mk ao25f 6',i2- .2�r -J� fat �G •9 x12<7`,Ct•S fi- M/ ff -..asi CITY OF NIIA , DEC '0 9 1997 PERMj.6EMER .. -;; ®n 4 I s SANITARY SIDE SEWER I f L —SS 9s /zs /LL :31y0 flfl 4 1 ;I l$f fit - -� / a i . i•---.:1 ! 1I. A ? I kt it b k 1 il 7 OAR APR I City of Tukwila •W d g I obi y Allow i;t4 my i F!� 1 tftht 1 am unsr+ inn :4.0 .wns .v.rol +•. pu, . pill li Twill 9IgI I :1 11 ! � I I t I !i ! i!I!1 I !I1I 1 I 14A11 q h iJ I 4fl , !III iI 1 . J � u 1 1.14! Iiii flIijII4 li c ipm, . INI iiicohtikoA nviii Eitphol, Ai I A r 41i +Ili 1 41!11 igii!lial F 83• I Lit F ib hi I.. 9 tl. �'S1 5' ff41 h c� 4 _ N • a 9 l liy !do, 6 l dsd . d dau fig a a 3. a A 1 9 al I I 11a8A x mda h. . ada udd • In _ N11' EKED I -Alts Ina I r G. ATWOOD stnriotwsai8cton SE. iFP rd F SF�LO 9 hiss air.. LiCklE K. L. STLur itJPA- -L r*--I ( T ES project nm date: d r a wl? :Y.: : . AC PARTNERS ARCHITECTS 121 ' WESTLAKE AVE. N. suite IQ9' s STTLE;.WA.,984O9 28$-9332 s eol J.. 4. GENERAL NOTES These plans ware designed to conform to the latest edition of the Uniform Betiding ,..;:1e. Constant changes in building codes ,.. addition to changes in environmental qua)rflcatrons and ideal options for plumbing. heating /cooling and wiring. makes conformity to all building restrictions impossible. Censeiuently, i[ is the responsibility of the user to evaluate these plans for conformity to code requirements. any additional design or drawing services required are subject to A.C. .Associate_. Architects standard service fees. The contractor shall verify all dimensions and conditions prior to beginning work. and notify owner of any discrepancies. Written dimensions shall take precedence over scaled dimensions. DO NOT SCALE DRAWINGS. In the event of a conflict between applicable cedes and regulations and reference standards of these plans and specifications. the more stringent provisions shall govern. No variation required by a building official shall be binding on the designer. Specifications and drawings indicate finished structure- Builder Shall be responsible for construction methods. procedures and conditions except as spear fi.:ally indicated .,tnerw•ise in writing- All construction shall be per U.B.C. 144 - Edition- in the City of Seattle. use with t994- S.B.C. and Seattle Energy Code. All materials and construction shall conform to the drawings and specifications. The contractor is responsible for all required bracing during construction. The contractor shall eoerdinate all required building depar tenant inspections. Any modifications or revisions to the work shown on these plans shall be approved in writing by the architect. DESIGN CRITERIA Dead Loads Live Loads Roof with shingles /shakes I5PSF Roof 30PSF (= drift) Roof with clay /concrete tiles 25PSF Floor 40PSF . Floor IOPSF Deck 60 PSF Stairs. corr idores t00eSF Garage 50PSF or PT.LD. FOUNDATIONS Wind speed 80 MPH (exposure C) Seismic zone zone 3 Foundation Bearing Pressure 2000PSF Lateral Design Pressure Unrestrained cantilever walls. 35 PCF Restrained walls 50. PCF Footings shall bear on firm, undisturbed soil a minimum of l8" below the finish grade line and 12" below the line of the original grade for one and two story structures, and '24". below finish grade for three story structures. Foundation and footings are based on a soil bearing capacity of 2000 PSF. Verify local conditions and notify owner of any variation. Do not excavate greater than a 1X:2 slope below footings. Footings '.. to extend below frost line or 18" below finish grade, whichever is greater. All overexcavated .regions shall be repaired with structural fill. compacted CO 9th maximum Proctor density at optimum moisture content. Alternately, repairs may be made by filling with lean concrete (f'c =2000 PSI) Remove all organic material or debris and repair the region as per nole ,above. EIIVFORCJNG STEEL Unless otherwise specified, all reinforcing steel shall be Grade r deformed bars in accordance with ASTM A615. or welded wire fabric in accordance with ASTM A195, of the sizes shown on the drawings Reinforcing steel shall be securely tied in place with #16 double annealed iron wire. tap all reinforcing bars at splices 36 bar diameters minimum. De not weld reinforcing steel, except where specifically called for on the plans. On not tack weld reinforcing steel for placement. MINIMUM REINFORCING STEEL PROTECTION Use Protection slab bars 1" Wail Bars interior :faces 'j" Exposed to weather' IX Exposed to Earth 2" Footing Bars 3" Reinforcing . -Steel shall be bent cold. Welded wire fabric shall conform to ASTM A185 1'n as long a length as is practicable. Welded wire fabric shall be lapped at least one 'grid width plot 2 ". �o CONCRETE 1 All foundation wall and footing concrete shall develop a minimum compression strength of 2500 psi at 28 days. All concrete slats shall develop a minimum compressive strength of 2000psi et 28 days. Concrete forms, uhcr ing and pouring methods shall conform to current A.C.)- standards. Reekfill shalt not ce placed against basement retaining wails un till concrete or masonry grout has reached it's 2S day strength.and Structural floor framing (including subflcor) required to stabilize walls is complete and fully nailed and anchored. Apply lice and try Wall Preduccs.tnc "Thoreseal Foundation Coating" or equal on all exterior faces of walls below grade, and "Thoroglaze" or equal d=- mproofing on ail exposed surfaces o"f concrete walls above grade and all slabs not covered by finish floor materials. The selection of materials for, and the mixing and placing of:ail • concrete shall conform to the requirements of the 144'UBC. Materials shall be proportioned to produce a dense. workable mix. which can be placed without segregation or excess free surface water. Except as approved by the engineer, water - cement ratios and cement content for various concrete strengths (f'c) shall be as shown below. Mlti -c c sacks maximum gallons Use f'c .- c.,..nt per +.arerper sick. 2000 55'v 7, - Lean concrete WOOD FRAMING - -- - -- - -__ - -- ---} ' tires All solid sawn lumber shall bet Bemg e Poi m9,:F-e.:,- installed as noted on the plans and connected as specified in the nailing scheacle below. Lumber shall be graded in accordance with current- Western Wood Products Assn. standard grading rules. Lumber grades for uses to be: Posts. beams and headers N lue*l- . Floor, ceiling Joists and rafters # and better Sills. Plates and blocking #3 Studs.. )E}d /)c p... "S tud °[_ --F 7m 2" T &G Sub floor decking #3 Wall and roof sheathing r N X" CD exterior glue plyw'd Subfloor over joists " - " CD exterior glue plyw'd Underlayment X" under leyment grade particleboard Ole Lam beams AITC Industrial grade with dry use glue (Wet use adhesive for exterior use) Fb= 24-00psi V9- Fv- 1n5psi E= I.800.000psf Solid sawn lumber at visualy exposed locations shall be "clear" grade free of heart. e P All exterior wall, and interior bearing wall openings shall have a 4 x 12 #1 df /l headers unless otherwise noted. Framing hardware numbers shown on the drawings refer Co "Simpson Strong Tie" connectors catalog numbers. Equal connectors may be substituted provided they have the same configuration and ICBO approved load ratings. All connectors shall be onstalled with the manufacturers reccomended fasteners. and all holes shall be nailed. ?. II L In with :encr0te shall be pressure treated. Bolt 'ill plates to concrete with ..'a " ._J1 with V" minimum embedment at 4' 0" maximum spacing except as noted on the drawings. NAILING SCHEDULE Connection Nailing Joist to sill or beam (3)80 toenailed Bridging to joist (2)8d toenailed ea. end 2" T &G Decking to beams (2)16d toenail through lounge• Rim Joist to Joist (3)l6d face nailed Stud to sole plate (2)I6d face nailed ea. end Sole plate to Joists or blocking (1)16d a 16" OC face nailed Sole plate or top plate to studs (2)16d face nailed Double top plate (1)16d R16" OC face nailed Double studs (1)16d d 16" OC face nailed Corner studs (I)16d a I6" OC face nailed Top plates R laps /intersections (2)16d face nailed Headers to top plates (1)16d @ 16" OC face nailed Ceiling Joist's to plates (3)8d toenailed Joist laps over partitions (3)16d face nailed Ceiling Joist to rafters (3)16d' face nailed Rafters in top plate (3)8d toenai led with "Simpson" H - 25 Connectors- verify. Plywood subfloor to Joists (1)8d common .B 6" OC ti edges &le" OC in field. Plywood wall and roof sheathing (1)8d common R 6" OC B edges & 12" OC in field. All staples a minimum crown width of 7/16. All shall be installed with a minimum penetration into framing members of 1" and a maximum penetration. of 1'5/8" s, e , 4 1107 ES NOTES iii frame .ells _'.all n fated ....ere O trio.: se :..tad. pin t it" OC except ,- r p .c._ t. te oneureo ail . ails ex _pt ".,_.e net,. Cripple: ..,'cr all headers _..all to ccnci.. -,e•ms to sole pier. - Deucle .lists _ _er all "walls parallel to joists except where 3therwie lad. Block ail steel -_pie as required for sheathing. Solid blocking between all J o i s t s and r a f t e r s at supporting walls and beams except rim Joists. Double rim Joists at all walls parallel to to joists. Beams. Girders and joists supporting bearing walls or concentrated loads shall not be notched All rafters shall be notched to provide full bearing at supports. AIi joists shall have a ;inixun bearing of 2" at supports. - Lap all joists 6 - inimum at all interior bearing supports. Mud sills and ledger hoards at 00r.crece walls shall have anchor bolts of the size and spacing =hc on the drawings. Each board shall be secured with at least 2 bolus. and each board shall have a bolt within 12" of each end- Cover surface=_ behind siding. shingles and where indicated on drawings with Dupont Ty-ek building wrap or ecuain Provide double framing at all roof and floor diaphram penecra ti ons unless otherwise noted on drawings. Bridging or 2x solid blocking required where any Joist spans more than 10'. Firestepping re ?hired per section 25t6(F).diso Draftstepping and Fireblocking. i.t coil Ail Glu Lam's s11a11 be 21FV1 exterior glue. Pm ovide shop drawings to engineer and blu talon dept" for approval pm ior to fabrication. Provide 2 la: -ers of asphalt building paper between sill plate and concrete" Provide 2 joists under cripples for window headers at all cantilevers" house Garage Occupancy Separation 5/5 "`type tiG -W -B" on all walls(and ceilings if 2nd floor over) in gar=age. Garage to dwelling door to be self closing. tight fitting, solid core weatpre rstri pped and 1 - 34" min. thickness. Ducts piercing fire separation wall to be min- 26Ga. galvanized steel- Prefab Roof Trusses 'Roof trusses shall be noted on the plan and manufactured by the Tres Span Corp- _r equal manufacturer. Trusses shall be installed per manufacturers reccomendetion, complete with all blocking. web stiffeners and bridging. Submit shop drawings prior to fa brication.Manufacturer shall verify all lengths and web openings all truss drawings shall bear the stamp of a Washington Registered Professional Engineer. Roof trusses shall be designed in accordance with snow and drift - loading prescribed by "Snow Load Analysis For Washington" published by the Structural Engineers Assn. of Washington. (SE.AW) INSULATION Roof Vaulted areas Flat ceilings Exterior walls 201 studs 2x6 Studs Floor over unheated Spaces Basement walls Slab floors on grade Ducts in unheated spaces Cantilevered floors and Floors over Garages Furnace duct in unheated space Notes R-30 R -38 R-Ir R -19 R -19 - Rif lL= 10 R -10 Rigid insulation at exposed perimeter" R -5 R -30 R -35 Insulation to be installed with vapor barrier on interior face. 'Caulking or gasketing is to be applied at all exterior sills and Plates and all exterior envelop penetrations.( between window or : door frames and rough openings) ' All glazing and all . skylights to be double glazed. U -value 0.60 max with thermal break or DCLU approved. Exterior doors to beweat herstripped at head and Jambs. Minimum l" airspace above insulation In reef. MISCELLANEOUS All tub & shower enclosures to be wired. tempered or safety glass. Ail glass within 18" of floor or within 12" of any door to be temrered. Each bedroom shall have at least one window with a maximum sill height above floor of 43 ". and a net clear opening of 20" min. width and 24" min. height and a net clear opening of 5.7 square feet. All skylights must be plastic or safety glazing and mounted on a curb above roof. Maximum spacing in roof of 20 ". Skylights 7/32" glass- Combustible aim (furnace) Per UMC section 601, 602, 603 and 607. Metal fireplaces Installed per UBC section 1707 and UMC section 512. Provide glass doors. Install per manufacturers spat's. Smoke detectors shall be hard wired to house power and basement smoke detectors to be audible in upstairs bedrooms. Tub and tub /shower enclosures CO have X" water resistant gypsum board. and a hard. moisture resistant surface up to 6'0" above floor(min.) All exhaust fans, range hoods and dryers shall vent to the outside through sheet metal ducts. Sheet metal ductwork per UMC 1005 and table 100. Vent connectors allowed only in the same room with appliance per UMC section 915. All windows, patio doors and doors with glass shall be double glazed, insulating units with wood or thermally broken aluminum frames and sashes. _ER0 ¢e tJ tJ- '.Lnbfe All metal connectors labeled "Simpson" shall be manufactured by the Simpson Strong Tle Co. or equal. Exterior doors to be foam cora insulated deers, unless otherwise indicated. Provide I been fire wall between Garage and living areas and under all stairs where storage space is available. All doors between garage and living areas shall be 1 hour fire rated assemblies with I-U" solid core wood doors or code approved equivilants and self closing mechanisms. Every exit door shall be operable from the Inside without the use of a key or any special knowledge of effort. Every entry door shall have a visitor observation port. Every entry door including garage shall have a lockset'with deadbolr or deadlatch will at least a X" min. throw. Deadbolts or approved locking devices required on all patio doors(sliding) and openable windows so that lockcase mounting screws are inac resible from the outside. Provide #l5 felt under all e siding. All interior wallboard (GWB) to be y unless otherwise noted. All interior doors to be 1 - 3/8" flush face. Asphalt shingles to have #15 underlayment- 3 tab min. pitch 4 in 12. Wood shakes and shingles per UBC section 3203(G) & (H). Attic ventilation per UBC 3205(C). The net free ventilating ere. shall not be less than 1 /150 of the area of the spat e'ventilated.- ;hat the area coy ibe 1/300 provided at least 50% of the ' the upper portion of the space to be ventilated at least 3' 0" above eave or cornice vents with the balance of required ventilation provided by eave or cornice yenta. Foundation ventilation under floor areas shall be ventilated per UBC 2516(0)6. Opening in exterior foundation walls shall have a net area of not less than I square foot for each 150 square feet of under floor area. All footings and gutter drains must be tightened separately and lead directly to approved dlscharge.(seepage pit) Stairs shall have not less than 6'8" headroom. Handrails not less than 3¢" and not more than 3S" above tread nosing. Walls retaining drained earth may be designed for' pressure equivalent to that exerted by a fluid weighing not less than 50 lbw/ cu.ft. - Shower flow control limited to not more than 3 GPM. 1 Hot water shall most ASHRAE 90 -75 requirements.' P? QFj0 RECEIVED p R cr, Of Tulcwtu F$ \\19 - DEC 091997 i•' "" " - PERMIT CENTER rw ...r.nS\(1. } rl yzi3tt tai ib`' ewe, _- - 30 u Ai;4 2 _tfz "mss - sj-rG 2l = xts s-ruoS 4t4 1JF3 �:r. lga (( E ch't d Er . �'�':'" eiD F'co-rt -j • . = — fit" SN rCa. SGcG� = PdtPE;R SIDM1.16, cam : —h TtiD WALL: (SEE teo C LJG SLAB MIEN IMININFMMER