Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D97-0301 - KING COUNTY / DEPARTMENT OF TRANSPORTATION - OFFICE AND ADA RAMP
City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 102304 -9066 Address: 11911 EAST MARGINAL WY S Suite No: Location: Category: ACOM Type: DEVPERM Zoning: M2 Const Type: MOBILE Gas /Elec.: Units: 001 Setbacks: North: Water: SEATTLE Wetlands: Contractor License No: EVERGM *202KT OCCUPANT KING COUNTY DOT (TRANSIT) 11911 EAST MARGINAL WY S, TUKWILA, WA OWNER METRO ACCOUNTS PAYABLE SBANNEX- 5432 - 50706- D50314, 821 2ND AVE, SEATTLE WA 98104 CONTACT MARC DALLAS Phone: 206 684 -1332 821 SECOND AVENUE M/S 122, SEATTLE, WA 98104 CONTRACTOR EVERGREEN MOBILE COMPANY Phone: 206 861 -7400 P.O. BOX 687, REDMOND, WA 98073 k************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** sic******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: SET -UP ONE 14 X 60 FOOT MODULAR OFFICE. THERE IS NO PLUMBING. CONSTRUCT A DETACHED BREEZEWAY AND ADA RAMP. **********************'****************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 14,776.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N k******************************************, k********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 375.34 k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature: I hereby certify that I have read and exams - d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of wor . I am authorized to sign for and obtain this development permit. S i gnatur Print Name: DEVELOPMENT PERMIT .0 South: .0 East: .0 West: .0 Sewer VAL VUE Slopes: N Streams: 1 k_ (206) 431 -3670 Permit No: Status: Issued: Expires: Occupancy: OFFICE UBC: 1994 Fire Protection: AFA D97 -0301 ISSUED 10/02/1997 03/31/1998 Date: 10 *92_ Date: / °- C? °.9.7. . 9� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Permit., No: D97 -0301 Status. ISSUED Applied: 09/10/1997 Issued: 10/02/1997 k* k* k ° k *•k•k* k k k•k•k•k k k *•kA k *•k•k * ... Addr,es.s • S u :i •Ten`an t i`vpe DEVPERM • Parcel .: # 102304:-9066, 'k 44 : ?,.•ki{• *4•k•k•k *ik•k,* k:** *•k•k** *•k*•kk•k *•k* •Pe..rmi.t , Cond:i t;ions 1 Pr'ior." to moving the building on -site; a copy of the WSDOT mo permit, route m ap and pr.oposed. moving schedule shall '';be submitted to the Ci;ty;_ Dev'elopment mits,.Engineer, for dation. NO McN/IN +3`ACrTIVIT.Y: SHALL BE UNTIL HIS. ;VALIDATION;, NAYS BEEN::, FORMALLY RECEIVED OR : . TII E.. MOVER IAiS' CONTACTED THE: DEVELOpMENT,IPERM`ITS :ENG AT; ` ('206) • '433 `0179 . SEATF Y THE B11ME If:::;a WSDOT.: t ha':. not been approved tai,P,t'he move, =a''Ci ty..p,e.r�,m:i.t .wi 11 ` need to be applied' • xf.or CWSDOT l'E MST RECEIVEDY.ROUTE MAP h :SCHEDU : STILL ENDING). 1. i LE o change w i 1 1 >be made to the ' plans _unless approved :by the. Archite~c.t or Eng.ine'er and the Tukwila Building Divlsiorr P. perrits :hall ,1b.e ob through the Seatt,,l;e =i irig` County Uepar°tmen`t .`of Pub 1 i c Health , P l umbi ng wi 1 1: b e e i ns ' ct that. :a ergo incl'ud9�e 11 in i p yx 9 y t ,,; gas p p in g C 96 "1.722) Ele;trtrical permits shall be • :obtained :rthrbiagh the • Washington S:tat : el : Divisron ofJ'•'Labor °'arid Industr <.and:.a11 e,lectrica1.' wo.rtk wi,l. in` petted .1bv ti7at 'agency. 0243 6630) . T a` Al 1 } s p:e.chen wor 1r" shall be sunder sepa'r atel; permit l ssued th Ci tY,c:W Tuirwi'1,a. 7 1 ti inspeic't re ion uor da, and a ro ppved plan. sha l'l a va i abl,e`#� the ,Job's ite''pr�,ior� 'to' they star *t•. „of aii ; 'con strcko These, documents are to be and avai` able, unti l�; final ..I inspect ion approval .s granted. All coiistr=u'tlon to be done in conformance wi:t'h approved, . plans`'hnd requirements of the Uniform But i.ding” Code (1994 t° Edition)`: as amende'd,,, Uniform Mechanical Code,, ( Edition and Wash i:rr,gton ��•State - •E,nergy Code' (1994 ••'Edition) .' B. Validity of Permit.. The ,:issuance of a' permit or';approval plans, speci.:f icati,ons, and computations • `sha not: :`be con; -' strued to be a perniit for, or an approval of, any violation, of any of the provisions of':the` bui °.ldf'ng code or of. : army other,. ordi.nance nt:.the .jiurisdict'ion. : °''No permit :p,resuming to give authority to v i o l ate or cancel the provisions of this , code shall be valid 9. There shall be no occupancy, of the airs l d ing (s) until the final inspection has been completed b the Tuk,wi 1a Building Inspector. 10. VENTILATION IS REQUIRED FOR ALL NEW ROOMS AND SPACES OF NEW OR EXISTING' BUILDINGS IN CONFORMANCE WITH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, CHAPTER 51 -13 WAC. Project Name/Tenant: King County DOT (Transit) Modular Office Value of Construction: $ 14,776 Site Address: City State /Zip: 11911 Fast Marginal Way Tukwilla, WA Tax Parcel Number: 102704 9066 - 09 Property Owner: King County Existing fire protection features: ❑ sprinklers n automatic fire alarm ❑ none ❑ other (specify) Phone: (206) 684 -1332 Street Address: c/a 8 1 2nd. Ave. City State /Zip: MS 122 Se ttle. WA 98104 - 1598 Fax #: (206) 684 - 1900 Contractor: Evergreen Mobile Company Phone: (206) 861 - 7400 Street Address: City State /Zip: 8345 154th Ave. NE Redmond. WA98052 Fax #: (206) 881 - 6814 Architect: As Above c/o Dale L. Phone: — Street Address: As Above City State /Zip: Fax #: Engineer: As Above Phone: Street Address: AG AhnvP City State /Zip: Fax #: Contact Person: Marc Dallas Phone: (206) 684 - 1332 Street Address: City State /Zip: 871 2nd. AvP. MS 122 Seattle, WA 98104 -1598 Fax #: (206) 684 -1900 Description of work to be done: Set -up one (1) 14x60 foot Modular Office. There is no plumbing. Construct a detached breezeway and ADA ramp. Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel/Hotel in Office ❑ School /College /University Other Bus Rase /nffi cP site Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family Warehouse Hospital El Church ❑ Manufacturing ❑ MoteUHotel a Office ❑ School /College /University ❑ Other Will there be a change of use? CI yes a no If yes, extent of change: n/a • Existing fire protection features: ❑ sprinklers n automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: n/a existing 840 new Area of Construction: on 15 acre site Will there be storage of flammable /combustible hazardous material in the building? Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating ❑ yes a no quantities & Material Safety Data Sheets Date application accepted: Date application expires: AppllcaUon lak (lnit/als) CITY OF TIJkWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 New Commercial / Addition / Multi - Family Permit Application Application and plans must be complete in order to beacoepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS•SITE/CIVIL PLAN REVIEW. OF THE FOLLOWING: • (Additional reviews may be determined by.the Public Works Department): ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Hauling ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Moving an Oversized Load: Start Time: End Time: ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. PLEASE SIGN BACK OF APPLICATION FORM NCPERMIT.DOC 1/29/97 BU OR AUTHOR/ ENT: atu L J -de 4 . ` 2C. Date : Print nam�.l J►iZ C— • .� ( � C 1 �. F • /.9' 0 0 Address: �Z / �,e w'��,�y�. S. Z L Cit /State /Zip A r r E . WA .# O isie ALL NEW COMMERCIAL/ADDITION /II I- FAMILY PERMIT APPLICATIONS M BE SUBMITTED WITH THE FOLLOWING: )› ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ❑ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Copy of recorded Legal Description from King County ❑ ❑ Certificate of water /fire flow availability (Form H -11a). Contact the Public Works Department (206) 433- 0179 for servicing district. ❑ ❑ Certificate of sewer availability (Form H -11). Contact the Public Works Department (206) 433-0179 for servicing district. ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : Cl ❑ Site Plan 1. North arrow and scale. 2. Existing and proposed utilities and existing hydrant location(s). 3. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements. 4. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions. 5. Location of driveways, parking, loading & service areas, with parking calculations & location & type of dump - ster recycling screening. 6. Location and screening of outdoor storage. 7. Limits of clearing /grading with existing & proposed topography at 2' intervals extending 5' beyond property's boundaries, erosion control measures & three buffer protection measures. 8. Identify location of sensitive areas slopes 20% or greater, wetlands, watercourses and their buffers (TMC 18.45.040). 9. Identify location and size of existing trees, note by size and species those to be maintained and those to be removed. 10. Landscape plan with irrigation: Existing trees to be saved by size and species. Proposed: Include size, species, location and spacing. Location of service areas and vault with proposed screening. 11. Location of high water mark of the Green /Duwamish River if site is located within 200' of the high water mark. 12. Lowest finished floor elevation (if flood control zone permit required). 13. Civil plans to include size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. 14. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). ❑ ❑ Vicinity Map showing location of site ❑ ❑ Building Elevations (Include dimensions of all building facades and major architectural elements) ❑ ❑ Mechanical Drawings ❑ ❑ Structural Drawings (detail of sprinkler hangers, pipe, duct & vent penetrations in structure) ❑ ❑ Architectural drawings ❑ ❑ Specifications (if separate document) ❑ ❑ Structural Calculations ❑ ❑ Sprinkler structural calculations indicating load of water - filled sprinkler piping ❑ El Height Analysis ❑ ❑ Soils Report stamped by Washington State licensed Geotechnical Engineer ❑ ❑ Topographical and Boundary Survey ❑ ❑ Tree Coverage Analysis (Multifamily only ) ❑ ❑ Washington State Energy Code Data and Non - Residential Energy Code Compliance Form H -7 El Completed Land Use Applications if not previously submitted (i.e. SEPA, BAR, Variance, Shoreline or Tree permit) ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Pub- lic Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent if the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA WS9F THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. NCPERMIT.DOC 1/29/97 INSPECTION RECORD Retain a copy with permi INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 . Southcenter Blvd., #100, Tukwila, WA 98188 ()1,1.1, �T Project:. Address: 119 11 erA4 Special Instructions: T pe of inspection: Dates called: Date wanted: a. Requester: ��j o l Phone No.: Cox y -� . pproved per applicable codes. (206) 431 -3670 Corrections required prior to approval: COMMENTS: E1 $42.00 R INSPECT! • FEE REQU RED. Prior to inspection, fee st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, [eceiPt No.: Date: C . INSPECTION RECORD' Reta a copy w ith perm INSPECTION NO... CITY•OF TUKWILA BUILDING DIVISION 6300: Southcenter Blvd., #100, Tukwila, WA 98188 e t: ti Tome of inspection: Ion: • � C o . O aT �� nf1�l � ��it�..�.c � �' � r � ,Address Date calla Special instructions: Date wanted: am MSZIEZEINAIMEM �1..,.1,, Re e r:��� Phone No. � l ; COMMENTS: Approved per applicable codes. w. /4/2,41q? $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No.: Date: PERMIT NO. Corrections required prior to approval. • TIOn Refitter: 1 _ , ' INSPECTION RECORD, 1 . Retain a copy with permi INSPECTION NO. :; CITY OF, TUKWILA BUILDING DIVISION 6300. Southcenter Blvd:, #100, Tukwila, WA 98188 Proje of inspecti n: A Dat , tYlr nr� r�c�� 5 �C gated: \Lk Q� Special instructions: J Date wanted: a. . Phone No.:� 6‘ ,.. k ` � � Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:' Date PERMIT NO. (206) 431 -3670 •. $42.00 REINSPECTION FEE REQUIRED. Prior to irpection, fee must be pgid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: , 0 rm ' s rr+'Z"N:eY City of Tukwila Fire Department • TUJKWILA . FIRE : IMPARTMENT FINAL APPROVAL FORM Project Name 1► ,c) (.4N f 1 1 :Address`. (H " c' 0 1'0:40,(, 5 as) 2 Sprinklers: � �� Fire Alarm: 'ut!, a�� il , Hood & Duct: Halon: Monitor: Pre - Fire:. Permits: Authorized Signature FINALAPP.FRM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Permit No. ,1} CV - 3n T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Suite /o) 3 fl Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575.4439 .+ .. ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION PUBLIC WORKS REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F PQ.yM* CmOOT C�op,� PLAN REVIEW /ROUTING SL D97 -0301 KING COUNTY DOT (TRANSIT) FIRE PREVENTION 0 Pr&c, C I11) ❑ 17A DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE Eg NOT COMPLETE p COMMENTS TUES /THURS ROUTING: PLEASE ROUTE fl ROUTED BY STAFF 1 (If routed by staff, make copy to master file & enter Sierra.) DATE APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS ❑ DATE CORRECTION DETERMINATION: APPROVED I 1 APPROVED W/ CONDITIONS p REVIEWERS INITIAL DATE DATE 9/10/97 ( P DIVISION p E�t1GiIT 'C l l.. l OORDINATOR p DUE DATE 9/11/97 NOT APPLICABLE ❑ NO FURTHER REVIEW REQUIRED 0 DUE DATE 9/25/97 NOT APPROVED (attach comments) p DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) a�x ACTIVITY NUMBER D97 -0301 PROJECT NAME RING COUNTY DOT (TRANSIT) DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE COMMENTS • V 'in Ali Lb ntn U 46, PLAN REVIEW / ROUTING SLIP DEPARTMENT: BUILDING DIVISION 111 FIRE PREVENTION [J PLANNING DIVISION a PUBLIC WORKS STRUCTURAL El PERMIT COORDINATOR ❑ 4 DUE DATE 9/11/97 NOT APPLICABLE Q f1'e,4.'i11LWipF5 tit'A DATE 9/10/97 TUES/TITURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL I 2 APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVE r; WI CONDITIONS REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F DATE DATE DATE G DUE DATE 9/25/97 N • T APPROVED (attach comments) Q DUE DATE NOT APPROVED (attach comments) Q (Certification of occupancy required. t;: ACTIVITY NUMBER D97 -0301 PROJECT NAME KING COUNTY DOT (TRANSIT) DEPARTMENT: BUILDING DIVISION El u PUBLIC WORKS I DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n COMMENTS TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRE" ROUTED BY STAFF En (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) DUE DATE 9/25/97 APPROVED El APPROVED W/ CONDITIONS REVIEWERS INITIAL 1 I CORRECTION DETERMINATION: APPROVED REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP NOT COMPLETE APPROVED WI CONDITIONS DATE DATE DATE A.':' �h': a'FiF:T3�1YsY:T4Sl!}!'s".2iNN.« cA` 7xhlf a'^ rtSE§' tit4tl t3t4sra." tR�4Pt;!7 tY, ih�tP ?�eRktitD!�awta�ACO.an DUE DATE q/d DATE 9/10/97 FIRE PREVENTION II PLANNING DIVISION' a STRUCTURAL 0 PERMIT COORDINATOR El NOT APPLICABLE Q 9/11/97 I NOT APPROVED (attach comments) DUE DATE NOT APPROVED (attach comments) (Certification of occupancy required. ) PROJECT NAME DEPARTMENT: BUILDING DIVISION PUBLIC WORKS PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0301 RING COUNTY DOT (TRANSIT) DATE 9/10/97 FIRE PREVENTION E PLANNING DIVISION • STRUCTURAL PERMIT COORDINATOR 0 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE COMMENTS TUES /TIIURS ROUTING: PLEASE ROUTE TI NO FURTHER REVIEW REQUIRED ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL I 3 APPROVALS OR CORRECTIONS: (ten days) APPROVED /v ` DATE c/ l k I1 APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) Ei NOT COMPLETE E NOT APPLICABLE Er REVIEWERS INITIAL v DATE Cr / I l /r7 DUEDATE 9/11/97 DUE DATE 9/25/97 CORRECTION DETERMINATION: APPROVED APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F DATE DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy required. ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION El PUBLIC WORKS , COMMENTS • APPROVED fl REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP D97 -0301 RING COUNTY DOT (TRANSIT) DETERMINATION OF COMPLETENESS: (T,Th) $ 1 COMPLETE NOT COMPLETE FIRE PREVENTION PLANNING DIVISION ❑ STRUCTURAL El PERMIT COORDINATOR Q DUE DATE DATE 9/10/97 NOT APPLICABLE Ei 9/11/97 TUES /THURS ROUTING: PLEASE ROUTE gi NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF f1 (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL ' (J.J DATE 1 I is/ q - APPROVALS OR CORRECTIONS: (ten days) DUE DATE 9/25/97 APPROVED W/ CONDITIONS 03 NOT APPROVED (attach comments) Q / Cpl DATE CORRECTION DETERMINATION: APPROVED • [] APPROVED WI CONDITIONS DATE DUE DATE NOT APPROVED (attach comments) (Certification of occupancy required. ) 'U G. 113 57 R - 1 502.4 p' L - 313.19' I- :.l G 1 cC O ° LP I WOO' 29'OB' (10.00' R) 20 W' 1 4 R/w SR 999 .fFH L P �•�.. FACILITIN■ n / � • MAINT /NANO 1 �N/ r ',--; • • SELF -IL '�c.f. ' FLAME ,°"` •TD Q6 rG I) /N$/. -30 37 y� A••' -Wry e- 70 '!' t�_� e F-1.-..2.1:0:-4. 4f.F. 4 -14 N2CJ4. Gwer5-. I w .4,1r01..G a.ar. I T•F_ N LP. N 2913 fat 20'L9 5ETBACK N89'14'10 W(224.421 .7E-Z. LI REP PT. FOR OJMEN. ALONG N DT- Xe -D7'W N. 0 y 1 1. 1]9.0' ME' .7 -yr-.: 2 USGETT 4 PLAN 2,4 j LLJJ NI 0't4 9ETEACK _ N 2 A . CB R . 1,192.4 L - 229.19' OUT'. RI• S R q99 - �� • r29.o' Q I.�QK 7 4..tG.Lb _., L..JU.. G..TL ILO' r /' f -TI I ' IN .••••■nR .4.w,.. 4-C! / -T/ OI ."''•00 TI'S /2732.0 7 G'7 6' - It ^ • OP 41.1 .I.n.El s'TOan MAIN 2 ,1' 20' • 24 , 0 < p "+•.NO"rX /c•nr FER c -8 V REF PT. FOR OIMEN. 2 ALONG NO2' 29 -23 / n. _ 19a.16.TI2IJ ;O c 0�•• 07s1, CA 3.y IDEOMETAY 8TFIIPINL'SL FENCII\I t SITE PLAR! acAL[.t .ac: 20' DL10C43 G'4- 20 /00K GATE LO' DOI11&LE SwING GATE 0 P G6 • NG (GATE (.0) � DI G N ,ETB/`CK 2 L1. 517.0' IFL?TU?IS PHASE !I DSV[LOPM•NTI PAN E9 71,14 V A 4.: / .,,,s.rL 20' EJOtrG .S..T2 LANDSCAPING PER L -1 Kyle- 5...,Ir.L2•r �iJ..,Ee co,,*TSUCTIaJ IJI 4•2•4. 4T0¢1-1 17 4 - i -IOLJN AJ G•�J. r'1.e.p.e,, ^ e. L/5 SETBACK ¢..E L1 �J g P r - , L brat N do' ACCESS EASEMENT rorz ••6A42 IJ r02 WA L►.JE. u I.LGFif� ¢o. hE2, 01-.14. N.1 150. ARTHUR M. JAMES 'ENGINEERS INC • - PRIMII �ONBULTANTH 0 NEW C -N/C. u• CU -CULT) N 02'4 4-'W (00524-7 O J •00.0' _ ■KID PAD M1Z tG¢.iGS.Tgd 4.6.. y -i N r1Y,E.. of ;,44-05'x?' L N lf - J4CCR•• gOAp - PZOPOSIEP Fte D i D IC E E tL+bTAe1 h LE 4 LP 28 GAT 2S'DRIVEI✓AY This Drawing Rdduced To Wf•ne 0 4uhT' µ T•A1 20'>J0w EAT= n p ' - A 666 - £FORLir-R 42E E - s, • Y2 T -I° -,°c F=.ko PLAN 64..0' I_ 1JJM.IGIGAr EAr1P (.4). ( rE:R c - 141.7,1' ▪ 1 ` . 41 ___ .6 L "j'''"'. jjiiii ` ' - • L if d d "1 6D' C r A e. "AS CONSTRUCTED"- • tJSL / - Jo-71 11 C5 Ffwi D. AC4 J G (ub 4EE. 44 -I 99.5e // TR • TRAININ 1NIN • WT- \ gip - •��. hi lts HDL.DI• = 0). TT "crag t d. i • • ♦I p S UIT ` - d- F� 7 . 1 ECEIVE C •F T JAN '1 P RMIT C r2aP.2TY LIJE. ti RE CITY ' 1 1 kl a 27 DRIVVEwAY CS PLACES) 28 SUOING GATE (3 PL CEO ) 1 !I 3 /Gn e 1 {{1 5 1 1 LEGIEND CENTER LONE • PROPERTY LINE - -- EASEMENT LINE - C"--c- FENCE ± FH. FIRE HYDRANT 0 - • o LP LIGHT POLE \ o PROTECTION P091 0 • o FP Ft- ra-f.. - Aal1 s.C"f. 0 2CC < r,P , UNt_: NE - a G GO 6 0 �.G, 1 = aur iz7 G2' i PERM{ • C.J. CONLEE PROJECT COORDINATOR KCCH,BACHB &WHITTAKER, ARCHITSCTURAL CONSULTANTS u : I • DI Y .� .•.m. JG !� : rte • . - - '� w... JP_ METRO MLVI. C Iltr et Mclr00011tan S.101c t► II OUTH OP[A R TINO D 4ee[ ANNC:G Jlay:oeaMETRY3 IETRIPIND.ti CQ PIINCINO- ?LAN; M Jn. • R.ti•C 4 :C ILA 97 ER " EIVED F TUKWILA CENTER , . „ ;;:, .; • • King County Department of Transportation Transit Division, Design and Construction Services M/S SC ; • , 821 Second Avenue • Seattle, Washington 98104-1598 • (206) 684-2240 • Fax (206) 684-2284 Sep tember 29, 1997 Attention: Kelcie J. Peterson Reference: Building Permit D97-301' The occupants of the to be installed modular office building shall have direct access to the restroom facilities in the existing office. The existing office contains two restroom facilities one of which is barrier free. Very truly yours, Michael A. Paulson , 'Construction Management IV VQQY.Nk 40.4.Q WNN.u1QVASR4liAt., A Dear Sir: City of Tukwila Fire Department Review Control #D97 -0301 (CH 52) Fire Department Thomas P. Keefe, Fire Chief September 11, 1997 -.Re: King County DOT - Metro Transit - 11911 East Marginal Way South The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 3. A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1742. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1 - 1212.8) Local U.L. central station supervision is required. John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 Gni!• • Y4KWttY.A41/ City of Tukwila Fire Department Page number John W. Rants, Mayor Thomas P. Keefe, R1re Chief (City Ordinance #1742) 4. 41 work, and equipment shall conform .strict.ly.to the standards of The National Electrical Code -(NFPA 70) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 5. For all commercial, multifamily and single family subdivisions, hydrants shall be placed so that a hydrant - i l s within 150 feet of a building and so that no point of a building (around it's perimeter) is greater than 300 feet from a hydrant. Distance from a hydrant to a building is measured along the path of vehicular travel. All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (UFC 901.3) 6. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) 7. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 5754404 • Fax (206) 5754439 AUG -27 -97 WED 15:08 - ?jo l JUL 28 '97 09 :49AM WSDOT R--5 r BRIDGE 01- IA1AA (n « . •' I A!1 YHRt r 1 N Dgt p A I ANbPORTAtION �ZaL� L` AT LOCATION: MOTOR CARRIER STAMM BEt LEVUE DATA MILTED: JUL 2s 97 10:31 AM NAME EVERGREEN MOBILE ADDRESS: PO ROX 1043 MARYSVILLE , WA )0 111 LO ME OR YIN NO: TRAVSPOATINO TRW : GROSS WEIGRI: LEGAL CAMACII•Y: EXCESS GROSS WEIGHT OM: 141 AS: DATES (F1109.0: FROM POINT TO: POINT ON MATE IIIOIIWAY3: ALL AFPROYP.D WASHINGTON STATE BIGIIWAYS #6: • t7: #9: 110: MAXIMUM WIDTH: MAXIMUM HEIGHT: MAXIMUM LENGTH: GARAGE TRUCK OVER AXLE WEIGHT: SUSPENSE NUMBER: TRANS P► t NUMBER' . TIM AXLE WEIGHTS s OVIDtWEI1GIt OR AXLESPACWO: OP >D: LYR VENDOR NO. 19(47007 REPORT NUMBER: HQ AftUVAL: ate 9,3x70 111: #12: l4; 115: 017032: UNIT MUM; tt, P.01 P .1/2' 'i.r:e. >i Vidkd_ TRAM MIT I LIMITS NO. AXLES; VARY 114`tN.4E 02 VIN NO: RUNS ItE9TR>iCT>,f es SPECIAL CONDITIONS: - 5ION IN COLORED INK (NOT BLACK) TO VALIDATE PERMIT. CARRY FAX PE pIfT IN VEHICLE AT ALL MIS. OVERSIZE LOAD 8ICoN3 REQUIRED. FORM 560 -002 ATT C IE MAD TIIIS u #ORE. UGNN ING: T1.JQ comm.= tolvo►noMN PGRM(T ISSUED IN ACCORDANCE WIN R.O.W. *AMAX WRH1NE smIRCUNDERETN.IDINO THAT ALL APPLICABLE WAI NNOTioN EWE LAWB. ADA4NISTRATTV6 tome: U ATON6AN I CCM,YPONs. INCLUDING THOSE NOT =ED H E R E O N Wu. ea C O I O F .IED WITH. 6 THE tRiOERS1GNtED PIEHogrTM O R D T THEREOF. C E N T V Y T R A T TH6IIf03MA11ON MOWN HEREON IS K N Y A ND 1B TRUE AND CORRECT AND UNOERSTANO TWAT -HG PGRMITTEE SHALL BC LIAtr t AS SET FOkt1i vNRCNJ 0,+ 1, 1toFOR ALL DAMAGES TD ANY PUDUGt4IC: 1wAY. ORRIN RESULT= FROM TtEMOVBAENTOFECRI:>A1iNTAM R EDGY THIS PERMIT ON 'ME TAMEM HIGHWAVD OF 'MS STATE. TOE PER/CMsNALL FURTHER PIOLo pumas= Mp HARK= AND IDeRZaFYTHP ATAtti; RS CFFICERs. AGENTS AND ENMLOTWES AGAINST ANY VOMIT, UA*LITY, LOSS, JURY A1:OON ANOThE COSTS TME3g9F mom Rom Tug mot/crag OP ENAMMS OF THE PERMITT1:E IN STRUCTUIES HAVING A W Q «,t:AR L I4AN THE P MMTTTED HEC HT FORRT R R Ar D I�AI A TNG P ED EtE IS INSURED ED IN COMPUAt WAC Aaa, � Tel TT v.• ��, r T , '� 1 `YT r ` i...wT 74,���T �1*� v VIGY.AT1ON Of StSCIAL Y S • MALTY: FOR FAILURE TO OBTAIN, MISREPRESENTATION OR VIOLATION OF SPECIAL PERMITS, STATE I.AVV PROVIDES FOR A FINE, CONFISCATION AND SUSPENSION OF PERMIT WITHOUT REFUND. NO REFUNDS AFTER THE START OF THE EFFECTIVE. DATES. nor 1 OK1GnYALt�a:arfi[lST»r ON CIB 4.r••• to . 4 eOCs_t'O _ KI LRtSt't osp pm Oh VMS Miff lYK4 Post -IP Fax Note 7671 My commission expires: 2/11/00 Residing in: Redmond, Washington r `" - C L° c:DZO ( rfzc�n DOOR 3' -0" .6 - AiS if 7 UNE Q 14/ ) - F'gut -1U - 2 ?ER. DWG. L -1 (;) 036f SITE PLAN e,d 110 Office NEW OFFICE UNIT 12' X 60' ;-4U> f7L I Z I-- g. - naEs I y-L' . -PLUM) z CA L- -) .5 L- I GAL. _ . -- 3`0. G ttLI OFF L DOOR 3' -0" � -� c CITY OF TuKWILA SEP 2 9 1997 APPR SEP 3 0 1997 R !VUt LL) 31, 3'‘! C L A l t Co r �Y �J PERMIT CENTER /p7- ALL U G, & ORE 1�1G611 DtDIZE - 12: Pte{' 3rh/P - Sic /ER GG /G/H C._ S /,ECS SfAD4,o A ) • 5Its FF 10) C jeT T & .• -tom . 0 i✓D, �P��) 2 �}-,r , KING COUNTY DEPARTMENT OF TRANSPORTATION TRANSIT DESIGN AND CONSTRUCTION SERVICES ENGINEER OFFICE ADDITION hRa,c"T 5 l LOCATIo J SCALE : I". J0' DRAWN BY N1,T DATE Viz - II - 1b RECEIVED CITY OF TUKWILA PERMIT CENTER 024 SCALE: 1/4" = 1' -0" SW -2 I MIN REQUIREMENTS PER NREC: INSULATION VALUES: CEILING WALL R -21 R -11 GLAZING: MAX U FACTOR MAX SHGC .90 LO DOORS, MAX U FACTOR: .60 NOTES: 16 GA STAPPLES @ 6 "OC EDGE; 12" OC FIELD 16 GA STAPPLES ® 4 "0C EDGE; 12" OC- FIELD 1. THIS BUILDING MEETS OR EXCEEDS THESE REQUIREMENTS BY THE PRESCRtTIVE COMPLIANCE OPTION. 2. PROPOSED GLAZING % OF G.W.A. = 1.1.9% 3. SEE SCHEDULES AND BUILDING SECTION FOR ACTUAL INSTALLED VALUES 5 8/11/97 8/19/97 MARK 1�1 03) 1 -(RH) (1 1 -010 1 -(RH) FF10E OFFICE -(RHR) - 3'- 0 "x6' -8 METAL INSULATED DOOR W/ WD FRAME, RO: 38" x 80 -7/S' AND BRICKMOLD W/ 2 "x30" RE -LTTE ©40" A.F.F. WAIL THICKNESS: 5 -3/4 ". - HINGES- 1 1/2 MFR. STD. x 268 x BB x NRP PAINTED FINISH. - WEATHER STRIP- STANDARD PEMCO. - THRESHOLD- STANDARD PEMCO. - SWEEP- STANDARD PEMCO. LOCKSET- MFR. STD. KEYED LEVER ENTRY x 26D (KEY ALIKE) 1 -(RHR) DOOR AND WINDOW SCHEDULE 4'- 0 "x4' -0" DUAL GLAZED ALUMINUM SLIDER, 10 BRONZE ALUMINUM FINISH, CLEAR GLAZE W/ LEV7.LOR MINI BLINDS - CB - CB - CB 104 I OFFICE 1051 OFFICE 1061 OFFICE - GB 1071 NAIL - EG' - DESCRIPTION CB - i CB - CB CB - CB Y V - =P, - `t GB Nun - ,YV - uzr9 (R I ArT 7` - FLOORS 1 VIN - SHEET VINYL: SEAGATE, #86515 ROSE BEIGE RB RUBBER BASE: ROPPE TBD BAS - BASE CASING COLONY OAK WALLS CB -- 1/4" CINNAMON BIRCH PANELING vWB - VINYL WRAPPED GYPSUA;1 WALLBOARD CEILING ACT SUSPENDED ACOUSTICAL CEILING TILT 2'x 4'x 5/8 ". LAY -IN (INSTALL PER UBC 47.18) 3 HOLLOW CORE WOOD DOOR W/ WD FRAME RO: 38 x 82' ' HINGES- 1 -1/2 - PAIR MFR. STD. x 26D WALL THICKNESS: 4 ". LATCH- MFR: STD. LEVER PASSAGE x 26D FINISH: ALPINE OAK UNDERCUT DOORS FOR RETURN AIR RO: 48" x 48" THERMAL BREAK. WITH LOCKS & SCREENS. I SILL HEIGHT: 34". - CB - CB t ACT 17' -11" V1N - CB - ! CB i ACT I 7' -11' Y! - CB - GB - CB - I CB ACT -11" VIN SAS ACT i 7 -11" VIN PAS ACT I7 -1i" V1N M AL,t I 7.-- 0" 1 1/2" 3' -0 " 1„ 02 ROOM! DESCRIPTION I Y'�. ROOM FINISH SCHEDULE NORTH EAST WEST SOUTH I CEILING WALL WALL ! WAIL WALL MAT EN MAT FN j MAT FN MAT FN FLOUR MAT I HEIGHT i MAT BASE BAS • 01 02 1031 OFF CB - I CB COMMENTS N. BAs MK STRAP/HOLD DOWN FASTENING SCHEDULE STRAP /HOLD DOWN SIMPSON #STA6215 (WALL TO FLOOR) 6' -8" GENERAL NOTES RE FASTEN PER MFR. SPECS: INSTALLED IN PLANT (8 REVD TOTAL) GENERAL NOTES 1. ALL STAIRS, RAMPS, LANDING, AND CANOPY TO BE SUPPLIED AND INSTALLED ON SITE BY EMCO. SEE SHEET 6 -0 FOR PLAN & DETAILS. FOUNDATION NOTES: 1. CUSTOMER SHALL PREPARE SITE, EMCO TO SET AND LEVEL MOD. EVERGREEN SHALL MAKE ALL STRUCTURAL MA CONNECTIONS ENERGY CODE / BUILDING ENVELOPE 1. BUILDING HEATED BY WALL MOUNTED HEAT .PUMP ELECTRIC RESISTANT HEAT NOT ALLOWED` 2. ALL WINDOWS AND DOORS SHALL BE SEALED, CAULKED, GASXETEO, OR WEATHER STRIPPED TO MINIMIZE AIR LEAKAGE.. (WSEC 1314.1) 3. ALL VAPOR BARRIERS SHALL BE A MAXIMUM OF 1' PERM. 4. BUILDING ASSEMBLIES= USED AS DUCTS OR PLENUMS SHALL BE - SEALED CAULKED AND GASKETED TO LIMIT AIR LEAKAGE. (WSEC 1314.3) RESTROOMS TIN'S PLAN IS IN ACCORDANCE WITH -WAC 2900, QUANTITIES & ' RATIO'S TOILET FACILITIES ARE PROVIDED. IN AN ADJACENT BUILDING, SEPARATE - FACILITIES FOR FOR EACH GENDER PROVIDED IF THE NUMBER OF EMPLOYEES FOR THE NEW MODULAR EXCEEDS 4 PERSONS. ALL NEW FACILITIES SHALL BE BUILT IN ACCORDANCE WITH WAG-51-20-310.5 FOR BARRIER FREE ACCESS. THE OWNER /LEESEE SHALL VERIFY BY LETTER TO L &I THAT THE LOCAL BUILCING DEPARTMENT HAS AGREED TO THIS CONDITION. ELECTRICAL / LIGHTING I. LIGHTING CONTROLS SHALL BE PROVIDED FOR EACH SEPARATE AREA, READILY ACCESSIBLE AT THE POINT OF ENTRY /EXIT. CONTROLS SHALL BE CAPABLE OF TURNING OFF ALL LIGHTS' WITHIN THE SPACE (WSEC 1513.1) 2. MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM A SINGLE SWITCH OR CONTROL' SHALL NOT EXCEED A 20 AMPERE CIRCLIT LOADED TO; 30 %. CAPACITY (WSEC 1513.2) ALL LIGHTS WITHIN DAY LIGHTED ZONES SHALL BE PROVIDED WITH INDEPENDENT CONTROLS SEPARATE FROM THE GENERAL LIGHTING- -(WEEC 1513.3) 4. EXTERIOR LIGHTS SHALL BE CONTROLLED BY A PHOTOCELL (WSEC 1513. 5. BUILDING .SHALL. BE WIRED IN ROMEX. 6. SERVICE ENTRANCE TO BE UNDERGROUND: 7. SERVICE CONNECTION SHALL BE MADE ON SITE BY CUSTOMER. 1. ALL CONDUCTORS & CONDUITS SHALL 'BE BE- SIZED & INSTALLED TO COMPLY WITH ' hhE 1996 EDITION .OF'Ti-IE,N.E.C.. 6 ' -8 „ SW -1 NOTES: A) 1 2" 3/8" PLYWOOD (INTERIOR F.O.S.) 3/8" PLYWOOD (INTERIOR F.O.S.) 60 0 BUILDING AREA.. EA• . 840 s f OCCUPANCY GPO'IP: 8 OF OCCUPANTS: 8 CLIMATE ZONE: 1 SEISMIC ZONE: 3 6` -8 FLOOR R -19 CODE ANALYSIS FOR BUILDING 3' -2" SHEAR WALL SCHEDULE 0 N MARK SHEATHING FASTENERS 16 GA STAPPLES ® 6 "OC EDGE; 12" OC FIELD 16 GA STAPPLES CcD ;4 "OC' EDGE; 12" OC FIELD THIS STRUCTURE MEETS CONSTRUCTION REQUIREMENTS WAC 296 -15OF (UBC) BUILDING TYPE: Y 1 ROOF LIVE: 25 WIND HORIZONTAL: 80 mph EXPOSURE: "C" FLOOR LIVE: 50 psf SOIL: ASSUME 2000p.s.i. /HEAT PUMP REF MAX % OF GROSS WALL. AREA: 15.0 6'- � Date Permit N.D. 3' -2" . 6' -8 1 /2 " 0 Ma. 1 ZYr t OF n 2 -0 FILE COPY understand that the Plan Check approvals a re ubject to errors and omissions and approval of plans does not authorize the violation of any I adopted code ordinance Rey ,I_r of con- tractor's copy of approve ns acknc.siledged, (a, a V i 1.0 2.0 3.0 4.0 5:0 6.0 MARK IL JOB NO. 3119 D BY GJI 0" r ° . 4F't',fr PERMIT s' - 1 /' I )GrQ 'IRED FOR: �J INIECHANICAL PELECTRICAL 0 PLUMBING 0 GAS PIPING GAS rer�e�a t_Y OF TUKVVILA F'.0 LDSNG DIVISION DRAWING INDEX PRODUCTION SET FLOOR PLAN /SCHEDULES BUILDING CROSS - SECTION /DETAILS ELECTRICAL PLANS /SCHEDULES EXTERIOR ELEVATIONS/ COLOR SCHEDULE FOUNDATION PLAN /DETAILS STD. DECK /RAMP /CANOPY PLAN & DETAILS REVISION CUSTOMER SUBMITTAL LOCAL PERMIT SUBMITTAL CITY OF TUK'WWiLr EVERGREEN APPROVED 3 0 1997 L SIP HJ IxU i Li) B UILDING DIVISION LL 9' -2" 0 AUG 20 1991 DATE SALES: 8345 154th Ave. N.E. Redmond, WA 98052 (2 FAX 881 -6814 PRODUCTION: 14219 35th Ave N.E. 36 D)vif 8 7 98271 t 7677 An (387YY 659 -7731 IEPRCOMED 'WHOM WINSIDI CONSENT OF MOEN WOKE COIVANr s/N 797 -101 STANDARD PLAN NO. DATE 8/11/97 IP* • - Ir **J•AIPAIKIVIIMIP." Int ilx K - 75 , ,Y)< ' '' ._.. - -, '1>V2&•41111A.... ARKS 4M10 I* . iist - 4:-I-X: V AMIa.4.. -1/.. A. Aka......., a .. .. a . -.1■17... , .411..41■4111.- 411. A.A. A.A. .4". ... .s. .... 4 1t; i : _e- ■ ---'11 I L-- ., ........ I w"- #4131.210 Imo ito „ I — ----_ 1 I • - - ....- _. , , i Anlillallik 1.-- P" P*11110 *41111 I , ' ear pi,,,,,,, .- W■ • , ■'' , . , , , . ..,, --„„, 1 ,•' I j '...ft, 11 -0 .1 ----1 ..... AV ftii ..... ...... T■!!''. a .40 ...,'"..', 1110.. rpm 4111..' rota 111_■..; Illag, , -.0: 1 Otri ...ro „TA ....., IP... ... ... „.... -or R.-41, ift OP. r o .411t, .411 !Jo, 410-, ....is MI''' sr-, iiw P-41111r O., ar. .,_ 1 ' '3 10.411, '1.4. , ! W ■ aw.4 P.O. :0•410 ,....4 '11110.1 1.40 ' M ' 0. 1111111 0 0.4 W 0.4110 1 12 0410 41100.1 , Pile , .....1 CEILING GRID HEIGHT 9'-7 1/2" INT. WALL cINAmoN BIRCH PANELING COLONY OAK TRIM 2x4• H.M. #2 STUDS @ 15" 0.C. R-11 FIBERGLASS BATT. INSULATION CINAMON BIRCH PANELING COLONY OAK TRIM p.... ....• 'Poll* 11110.4 '1.1111 , 0-00 '110.-1 (1100.4 PP*11. ' 0.4 ' 0. , 111104 . oft ■ 111111.4 , 411.4 !We. / FLOOR FINISH FLOOR SEE FINISH SCHEDULE ON SHEET 1-0 I 3/4" T&G JDLX PLYWOOD SUB-FLOORING 2x12 FLOOR JOISTS (4 16 O.C. DOUBLE RIM JOISTS R-21 FIBERGLASS BATT. INSULATION MOBILE FLEX UNDERCLOSURE 7.er I i i , i 868686686TMELQ 8/99,A" 1 1 c8 • cbtb 88 8ii 3 8 . hi .........2—.--. I FOUNDATION BLOCK STACK 2x12 STAGGERED BLOCKING 15 MIDSPAN SEE SHEET 5-0 FOR FOUNDATION PLAN AND DETAILS III ■ 5 ,-,--I -....•...- ACESSM2146.40111.18=191.1931.7a, ROOF El _INC COOLE Si ISLE MEMBRANE. ROOFING MECHAINCALLY FASTENED 4" RIGID FOAM INSULATION R-30 /2" OD X PLYWOOD ROOF SHEEiHNG F.S.--25 0 'AC H END • 2x8 CEILING ..jc 24 0.C. SUSPENDED CEL I 0 • -1 I GUTTER & DOWNSPOUTS INSTALLED IN-PLANT EXT. WALL CINAMON CINCH PANELING COLONY OAK TRIM 3/5" CDX PLYWOOD SHEETING 2x6 H.F. #2 STUDS © 15" O.C. FIBERGLASS BATT. INSULATION T1 -11 SIDING W/ 4" GROOVES C.C. VERTICALLY 5/855 1/2" SACOMY TRIM TYPICAL EACH SIDE OF BUILDING COLOR T.B. D. Z FLASHING T1-11 SKIRTING INSTALLED ON BY EMCO LINE-UP GROOVES Z FLASHING INSTALLED ON-SITE BY EMCO ROUGH SAWN 5/8'x8" P.T. PLYWOOD INSTALLED ON-SITE JY EMCO 0 ----■ GRADE SLOPE 1 1 /2' ,,----- ALUMINUM DRIP R 1 x6 FACSIA TRIM COLOR T.B.D. 7 -10 71. 13 SCALE: 3/4" -= T'-0" cfri NPPROV SEP 3 0 In? h.) WJILI., BOLDING DNISIO% RECEnr CITY OF TUKW1LA 1 3 lirt:i* PER CUTSOMER SUBMITTAL 8/11/97 8/19/97 MARK EV'ER GREEN Redmond WA 98052 154th Ave. N.E. BILE 4 -18400 PROD A 11111 PANY kr:61 177735 98271 INS MING Mir BE NERIDDLICO Moor MIEN maw OF mum weLE 4 ' 3 N°. 3119 CAD FRE 3119 RE b 2 0 1991 s/N 797-107 STANDARD PLAN NO. DATE 8/11/97 DATE 49 NAUE METRO KING PI / 14'x60 OFFICE LJBC DRAWiNO C O. , 1 . SECTION Z.L.1 DETAILS a u ---- 111.611111111111111111111111111111 111111111111111111111111111111.111111 I _ - MR -, lite AL. 0 i , r i I i u_ • 0 1 i 1 ..... • o I ! Zd' — ® o f f _1_ 4 101 ‘N - 4 - I 1 of ZA — —I , ' ® 1 o p— — Z�. --- ' 1 0 ; \ 1 a I 771 -1-7 1 I- — 041. __ l - - — 71 — 7' (2 Il ■ 2 02 F2 I AL 1 F2 ,..-- / . ..© F2 2 1.11511M 4 _____, r: ,--_,3 Et v A co Si ________ r ____ 2 2___ i I WEATHER PROF j--BOX WITH covER PLATE (SIGN LCHT OUTLET) BU I LDIN ELECTRICAL/HVAC/REFLECTIVE CEILING PLANS SCALE: 1/4" = 1'-0 WORIMEXISIR- W.P. 7. HEATING & COOLING A. BARD WH361—A 3.0 TON, WALL MOUNT HEAT PUMP W/ 10 KW BACKUP HEAT STRIP B. PROGRAMABLE THERMOSTAT MOUNT W +54' A.F.F. C. 1" DUCT BOARD W/ SEAMS TAPED AND SEALED DUCT SIZE x 28" 14', 8" x 20" @ 8" x 13" © 18' 4, SUPPLY MR GRILL: SHOEMAKER #104PD W/ 8"0 DAMPER & NO LABOR COLLAR, (6) REQ. E. TRANFER GRILL: RETURN AIR GRILLS W/10"0 FLEX DUCT F. RETURN AIR GRILL 30"x14" WALL MOUNT 8. ELECTRICAL REF A. PANEL: 100 AMP 120/240 VOLT W/ MAIN BREAKER, UNDERGROUND SERVICE PANEL #-: QO 112M100, W/ UF COVER B. SERVICE WIRES: (2) #2 BLK THHN, #6 WHT THHN, its GRN THHN C. SWITCHES: ONE—WAY & THREE—WAY D. RECEPTACLES: DUPLEX, +18" AFT E LIGHTS: FLOURESANT TROFFER, W/ DIFF 2 TUBE, 72 wATrs, CBM CERT. BALLASTS (12) REQ. F. CIRCUITS, WIRE: USE 1. Q0 120 12/2 W/GRND FOR RECEP 2. 00 ' 20 12/2 W/GRNO FOR RECEP 3. Q0 120 12/2 W/GRND FOR H.W.T. 4. QO ! 70 12/2 W/GRND FOR LIGHTS 5. QO 120 12/2 W GRND FOR SIGN LIGHT 6. 00 260 (2) #6THW, #10 GRND TO, QO 6/12 1100 R/B DISCONECT FOR HVAC 7. QC 2100 FOR MAIN G. 2" MASTHEAD H. WSEC LIGHTING BUDGET 777.36 sqft .X 1.2vtotts =- 932.84 watts allowed (12) 2 TUBE FLUSH MTD. = 864 watts installed L EXT. LIGHTS: H.ARRIS 34.)4 W/ PHOTOCELL CITY OF TUN! APPROVE SEP 3 0 199 BUILDING DIVIS WEATHER PROOF 3—BOX WITH COVER PLATE (SIGN LIGHT OUTLET) 93,951E.811020.2:441r,.....99.1 __RECEIVED Ulf Y OF TUKWILA PE „ MARK REVISION CUSTOMER SUBMITTAL LOCAL PERMIT SUBMITTAL AUG 20 1997 DATE 711/97 8/19/97 EVERGREEN 150h Aw. N.E • Rodiromi. WA 98D52 MOBILE 4 PRODUCTION, 14219 35th Ave. N.E. COMPANY M3 AX 859-7735 *Rs mom mato BE ReRODUCED Yam:or cacao OF BECOEB4 NSW COMO JOB NO. 3119 siN 797-101 DRAWN EN. GJI CAD FILE 119-3—O METRO KING CO. 14:x60' OFFICE UBC STANDARD PLAN DRAWNG ELEC/HVAC/C El LI N G PLAN/DETAILS DATE 8/ 1 1 /9 7 SHEET OF a 6 /// D9 FRONT EXTERIOR SCALE: 1/4' • = 1'-0" LEFT SIDE LEI- I SIDE ELEVATION S EX T L!CHT W/ PC EXT HORN STROBE REAR MIERMS:05.1:11.1 1.1114.9■46.3 CITY OF TUKWILA APPROVED SEP 3 0 199? M ULU BULLING DIVISIOtv –—T 1 1 SaNG VI/ 4" GROOVES rNiSH iRTING iNSTAI LRD ON SITE DRAWN EN Gs! METAL DR iP FAIL h FLOOR 1x4 VOLID ,TRIM TYP, 'a ALL 'WINDOWS REVISION DATE LOCAL PERMIT SUBMITTAL EVERGREE S : 15 154th Ave. N.E. Redmond, WA 98052 (206) 861-7400 A MOBILE PRODUCTION: FAX (206) 881-6814 SG 14219 35th Ave. N.E. COMPANY Moryevlle, WA 98271 (360) 653-7577 FAX IMO 659-7735 DIS WOO MDT BE REPRODUCED 1616OUT 681194 WIMP OF EVERGREEN LOME COMPANY .109 Nro. 311 siN 797-101 GAD ru xxxx-x-x STANDARD PLAN NO. DATE 8/11/97 8/19/97 "' METRO KING CO. 14'x60' OFFICE UBC °PA" ELEVATIONS 4.0 ------- - jOF 6 SIDE VIEW [ -4 - - - ! I / I I I I L _1 TYPICAL FOUNDATION FOOTING DETAIL SCALE: 3/4" = FRONT VIEW f1 ff if L _J L _J - 1 — - 1 I I I 1 1 I t T_ J LL i - L L I - FOUNDATION PLAN .„L GRADE i 2 (MAX. SPACING 3'-t5" 0.C.) 71 L J MATERIAL SCHEDULE [I:TY . GENERAL NOTES REF A. SET A LEVEL CONCRETE BLOCKS ON CONCRETE PAD BLOCKS AT THE SPACING SHOWN ON THIS DRAWING. B. PLACE WOOD SHIMS ON TOP OF THE BLOCKS TO LEVEL THE MOD. C. ASSUME 2,000 P.S.F. SOIL BEARING, VERIFY W/BLDG DEPT. 2. FOUNDATION D CITY OF ROO APPROVED SEP 3 0 1991 0.) f BUILDI gtOTIELA NOTES A. PIER BLOCKS: 24"x24"x4" CONCRETE PADS, B. 8"x8"x16" CONCRETE BLOCKS C. 4"x8"x16" CONCRETE BLOCKS D. WOOD SHIMS AS NECESSARY PERMIT CENTER E. TIE DOWNS: IRON ROOT ANCHORS WITH "MINUTEMAN" STRAPS (OR EQUAL), APPROVED FOR THIS INSTALLATION TYPE 1 CLASS "B" GRADE 1 STEEL STRAPPING 1-1/4" x .035, CONFORMING WITH FEDERAL SPEC. 0Q-5-781-H MIN. BREAKING STRENGTH 4,725 LB. MARK 0 REVISION CUSTOM LR SUBMITTAL LOCAL PERMIT SUBMITTAL EVERGREEN COMPANY DATE 8/11/97 8/19/97 SALES. 8345 154th Ave. N.E. Redmond, WA 98052 (206) 861-7400 MOBILE A PRODUCTION: FAX (206) 881-6814 •0 14219 35th Ave. N.E. Marysville, WA 98271 (360) 853-7577 FAX (360) 659-7735 111:3 DRAWING CiNt41T DE REPRODUCED 'MDOJT WRITTEN ?SENT EYERGIEN NOBLE CrAIP/Wf JOS NO. 3119 DRAWN BY GJI CAD FILE 3119-5-0 METRO 14'x60' OFFICE UBC 797- 101 SIANDMD PUN NO. DATE 8/11/97 KING CO. '5.0 L ‘.1 CR OST RE0',,J CONT!NUOUS LEDGER 2 8 TO 4`-- 0" SPAN 2 x 1 . 0 7rD -O' r S N \, BOARD 'Ai /7" X LAO BOLTS. , 4 2 X4 SUpPOR ; F-:,.1M PAD - „ -„ - LEDGEk u.bp:NL, OCCURS CONCRETE FADS V,HERE BLDG OCOL, KrIETAL OR RAIL WITH FUIL ETL., RN 4 ENDS SLOPE OF RAMP IS THAN , CAG 0 NAL 2 , \ 4 ' L POST ',A/HERE DU DING ----- DOR' r C UR CD I') z LL.1 n LJ z „LT: 0 ( „ < - 7v, DECK/ RAMP SECTION ) '3/4" = Lit 7i - 1 ---- --- -- 1 1 - l i"1 f ri I I 11 1 ' 11 11 III il 11 i! II li 111 !I 11 ,, 1 II ill 11 II L_,4,D1!qG 11 III 11 II 11 ii 111 11 11 11 1:1 11 11 1 , III 11 11 11 1 111 II 11 11 1 1L , 1 1 1 1 1 1 1 1 1 1 HJi _ 11 F.1 4 -0' ( .9:1.07XVC1817.117, 'TUFF H PLYWOOD FACE CRAIN 9C` TO jDST SDP JFRC - _STAIR WHERE -1- OCCURS (AHED -tt 2 X 4 SLIPPCRT - RC HOsT BASE TO 1.-DER NAIL TO SIDE CF posi O.j . PEPS— ,,, Hos! BASE smilsiosfasseszasaltemszsetazuma ammixamase I I 11 1 11 11 11 11 I I 1 I I I 1 I I I 11 11 11 11 2 X IC TOP RAIL 2x4 iNTERMEDIATE RA■L_S SELF .SPACED (STAFF LAYOUT FROM LANDING WORK UP) 4 SPACE MAX. BETWEEN N 4" X 4" POST sPACBD, 4 5'-4' 0 (8' - 4 TRIM , JO!ST 2 x 5 O 4 -S" SPAN 2 x 10 TO 6' - 0" SPAN W/ (2) 1/2 0 X 7" SLAV BOLTS 2 x 8 JOIST 4 •6" U.G. (r(P) W/ 6 SPAN x 6 JOIST © 16" 0.0. (,TYP) Wi 4' SPAN POST 5 11 I I 11 11 I 1 11 I I RAMP SLOPE 1:12 11 11 11 - I CONCR RIM JOST ETE PJERS TRIM 16•1111014071■MAIDOLESSI, 3561:88:070MMEXIMMIGWARSOWCZ... W/POST BASE RAM P LANDING, ELEVATION SCALE: 1 /2" = 1 1 1 ELEVATION r= ; CALL: — I I i I ! I 11 11 11 11 11 11 !I 11 11 11 11 11 C2DCURI2, (DASHED!) 11 I 11 11 11 11 11 11 11 11 11 11 x FLOOR GISTS W/ TAPER CUT 10 II LI DIAMOND PLATE 3/16' X 10" X FULL WIDTH W/ FHWS TO PANM 5'-4" RAMP—LANDING PLAN VIEW SCALE: 1 /2' = 1' -0" SET THE LAST TWO POSTS IN CONCRETE METAL STAIR NOSING — WITH 1/2" RADIUS AND NON-SLIP SURFACE /2" PROTRUSION MAO. TAYC, STAIR ANGLE , , , V,/ 1 /- ',C (2 D N.. SCREW 12" OC. "TUFF TPRADYPLYWODD , .-.. x - I 2 STA STB:NCER. N N N N,, N, N 'FM CITY OF TUKWILA APPROVED SEP 3 0 199, BUILDING DIVISION Aiffird1.4 AVIV / C 2x12 TREAD — TREAD DETAIL SCALE: 1 /2" = 1-0' GENERAL NOTES MARK ALL FASTENERS, HANGERS, AND PLATES SHALL BE GALVANIZED HOT DIP P:ED,STAINLESS STEEL OR EQUAL. ALL WOOD , 0SED 01 CONSTRUCTION SHALL EL TREATED OUTDOOR WOOD. PRESSURE. TREATED, REDWOOD, OR EQUAL. 'NHEN PROVIDED BY OTHERS, ANY DEVIATION FROM THESE PLANS SHALL BE THE .RESPON - SIBIUTY OF THOSE .OTHERS, AND NOT EVERGREEN MOBILE COMPANY. THESE PLANS ARE FOR TYPLCAL DECK RAMP CONSTRUCTION ACTUAL DECK & RAMP DESIGN MAY VARY DUE TO 5005 CONDI REVISION LOCAL PERMIT SUBMITTAL EVERGREEN MOBILE COMPANY " LAS/GJI CAD 'ILE 3 1 1 9- 6-0 1 4'x60' OFFICE (UBC) DRA STANDARD DECK, - DATE 8/19/97 SALES: 6345 154th Ave. N,E. Redmond, WA 98052 (206) 861-7400 FAX (206) 881-6814 PRODUCTION: 14219 35th Ave. N.E. Morn:vile, WA 98271 $180) 653-7577 rAX (360) 659-7735 INS mom weer BE REPRootan mour SYRRIEN CONSENT OF EVERGREEN NOBLE CINPNW j°81.4 3119 " 797- 1 07 STANDARD PLAN NO. DATE 8/11/97 METRO KING CO. 1 "EET6--0 1 RAMP & CANOPY DE TAII_S °F 6 1 1 /2" METAL OR WOOD HANDRAIL WITH FULL RETURN © ENDS (OPTIONAL IF SLOPE OF RAMP IS LESS THAN 1 IN 20) BUILDING LINE OR POST AS REQUIRED BY SITE CONTINUOUS LEDGER 2 x 10 TO 6' -0" SPAN BOARD W/ 1/2" X 4" GALV LAG BOLTS. 48" O.C. DIAGONAL 2 X 4 BRACING 0 POST WHERE BUILDING DOES NOT OCCUR 2X4 SUPPORT FROM PAD TO LEDGER WHERE BUILDING OCCURS NI-0501 2 X 6 TOP RAIL • is= Na CLEAR 12 60" (MIN. LANDING) 3/4" "TUFF TREAD" PLYWOOD W/ FACE GRAIN L 90' TO JOIST (NON SLIP SURFACE) JOIST HANGER CLEA X 4 SUPPORT FROM POST BASE TO UNDER RIM, NAIL TO SIDE OF POST CONCRETE PADS CONCRETE PIERS WHERE BLDG OCCURS W /POST BASE IN TRIM RIM JOIST — POST IS_ 24" 48" (MIN. RAMP) O DECK /RAMP SECTION A SCALE: 3/4" = 1' -0" 122 BACKING 1X8 WOOD RISER W/ 1 1/2" WOOD SCREW 12" O.C. 3/4" 'TUFF TREAD " /PLYWOOD 3212 STAIR STRINGER 2x12 TREAD METAL STAIR NOSING WITH 1/2" RADIUS AND NON-SLIP SURFACE 1 1/2" PROTRUSION MAX. SIMPSON TA10 STAIR ANGLE 224 INTERMEDIATE RAILS SELF SPACED (START LAYOUT FROM LANDING WORK UP) 4' SPACE MAX. BETWEEN 4" X 4" POST O TREAD DETAIL SCALE: 1 1/2" = 1' -0" 1 X 4 TRIM RIM JOIST © MAX 60" RAMP /LNDG 2 x 8 TO 4' -0" SPAN BETWEEN POSTS 2 x 10 TO 5' -0" SPAN BETWEEN POSTS W/ (2) 1/2 0 x 7" GLAR BOLTS RIM JOIST IP MAX 72" LNDG 2x10 TO 4' -0" SPAN 2x12 TO 5' -0" SPAN RIM JOIST @ 96" LNDG 2x12 TO 4' -0" SPAN O STAIR — LANDING ELEVATION SCALE: 3/4" = 1' -0" HANDRAIL OCCURS WHERE (DASHED) I� I II IIIANDING II Tr it I I I I I 1 I I II i! II 11 LL �I u 7 1' -0" T - I H I DIAMOND PLATE 3/16" X 10" X FULL WIDTH W/ FHWS TO PANM CONCRETE PIERS W /POST BASE \\_ SCALE: 1/2" = 1' -0" SET THE LAST TWO POSTS IN CONCRETE RAMP — LANDING ELEVATION RIM JOIST } TRIM v -2 x 6 JOIST © 16" O.C. (TIP) W /5' SPAN MAX. 0 01 III I I I I I I RAMP SLOPE T:12 II II II II II II 24" 10 SCALE: 1/2" = 1' -0" III 0 EXISTING SHRUBERY FLOOR JOISTS W/ TAPER CUT RAMP — LANDING PLAN VIEW 6' -0" MAX I I RAMP SLOPE I I I I (TYP) wi P.PPF SE? 3 0 1991 gu1lO1NG 01C RECEIVED CIN OF TUKWIIA PERMIT CENTER I I I I I I I I I I I I I I MARK DRAW CAD DRAWING GJI 01 JoB. No. 3119 1' POS DECK AND RAMP 5 -0" (MIN) REVISION JOB NAME METRO KING CO. CHECKED BY 797 -101 3119 -6 -0 DATE 9/4/97 0301 C) EVERGREEN Redmond, WA 98052 MOBILE A P- ODUCTON, 881 6814 ( r2y19 35th Ave. N.E. COMPANY PA% o) (360) 6597 35 SALES: 6345 15 IS DRAWING CANNOT: OE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MOBILE COMPANY SHEET 6.0 OF L m DATE 7