Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D97-0335 - STANDARD REGISTER - TENANT IMPROVEMENT
City of Tukwila C Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: Permit Center Authorized Signature:_ Signat Print WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. 262304 -9075 545 ANDOVER PK W BUILDING #1 AOFF DEVPERM CM V -N 001 North: .0 South: .0 TUKWILA Sewer: TUKWILA Slopes: "N DEVELOPMENT PERMIT (206) 4313670 Permit No: Status: Issued: Expires: Streams: Public: D97 -0335 ISSUED 10/28/1997 04/25/1998 Occupancy: Not in table. UBC: 1994 Fire Protection: SPRINKLERED /AFA East: .0 West: .0 Contractor License No: SGACO * *084BS OCCUPANT STANDARD REGISTER 545 ANDOVER PK W, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTACT RON GREENE Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTRACTOR SGA CORPORATION Phone: 206 778 -2191 6414 204TH STREET S.W. #200, LYNNWOOD, WA 98036 **************************************************** * * * * * * ** ** * * * * * * * * * * * * * * * * * * * ** Permit Description: BLANKET PERMIT AGREEMENT 97- 002 -BPA. INTERIOR TENANT IMPROVEMENT WORK TO INCLUDE DEMOLITION, CONSTRUCTION OF NEW WALLS AND INTERIOR FINISH WORK. r***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 87,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: No: Size(in): .00 Flood Control Zone: Hauling: Start Time: End Time:. Land Altering: Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start Time: End Time: Sanitary Side Sewer: No: Sewer Main Extension: Private: Storm Drainage: Street Use: Water Main Extension: Private: Public: k **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 1,334.40 *********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * *,k *1 * * * * * * * * * ** * * * * * * * * * * * * * * * * * ** * * * * * * * * * ** Date: hereby certify that I have read and examine this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the •rovision of any other state or local laws regulating construction or the p rmance of ork. I am authorized to sign for and obtain this develop en permit. Date /O 1Z,� J This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CERTIFICATE `OF OCCUPANCY CITY OF TUI WILA. S.OUTHCENTER. BOULEVARD, UITE.. 10 `TIIKWILA , •WASHINGT0N `9.137 i3E PURSUANT TO THE REQUIREMENT" ' OF sEf rIor4 10 U E - rHE 'TIF YIriG' THAT . AT,, ME ` TI` OF ISSUANCE THIS : :: STRUCTURE HE•.VARiOU . OROI�t'1ANCE ; C F :�Tt1E CITY` REI ULATING ;BUILDING ALL .APP ICABLE CITY jFIRC : CAGE ; , FOR THE FOLLOWIN& • • BLANI��ET AIsRFEMENT 97 L'k -0O L3PP ` INTERIOR TENANT IMPPOVEP ENT TO. INCLUDE DEMOLIT•ION, CONSTRUCTIQN OF`.NEW WALLS AND •INTEPIOP' FINISH ant. tsabaras Site Address: 5 4S Al4t0.00 e r Gu e .‹ w �-sT' TO V 1 ra, , kt.{ , q , \ p(r 1 Value of Construction: $ Q - 1 , 00C Project Name,Tenant: ''''-\^;--,e';', C 4 s © vC4-ve c\.O.r A Account No.: Zl O — S Type of Work: Tenant Improvement igk. Demolition (interior) 0 Other: Describe work to be done: z_Nt -e.,/ `� .reNC1/40t \ Mnlivov Me.).1 - 4 - ‘tK - s ro \4 -4 ....._ De o i t3e u30.\ \s E \ eci -.r per...` vv\eo kn t.., tom\ L I so v I< c & , f ‘11;--e..."1. va--../ C s� % s % W0 \/... . Building Type: Building Use (office, warehouse, etc.): - - , of _ e _ `c .2 SQc.1/4.c..,,k_ Nature of Occupancy (printing, manufacturing, etc.): busk e_s S v5 Will there be a change in use? a No . Yes If "yes ", explain: City /State /Zip: -}-y -� ,e W q c�1O' Square Footage - Entire Building: a0 Construction Area: -loon Tenant Space: • 1 pa) Will there be storage or use of flammable, combustible or hazardous materials in the building? No 0 Yes If "yes ", explain: • Property Owner: La��nvaeS 1Nvesto" vembrt-tes I Phone No.: p) Si S 2\ 243 Address: (oO lutaweArs\' S�reest- s,„,,,, re_ Z8 City /State/Zip :. i v,k.k ie _ . WF}. vm \o\ Contractor: sGPr. 0 r.r'7Dd'GLA- \ Q►.) Phone No.(,) 2_33 Pie)3a Address:G *14 2.sy4t\n s\ t. - 1 Su o+e. A 2c m City /State/Zip: Ly N W 4 crap WA State Contractor's License No.:Sh_szte.0 *. A, 0$Li 6 S ‘ Expiration Date: ■ Z /c - Architect: w c Phone No.: 2_Z3. - s - s - Address: I (i Sov �- � J ,, 5.�.,r e,.i- City /State /Zip: -}-y -� ,e W q c�1O' WA State Architect's License No.: 2_36 Expiration Date: v.3 Act I he y certify that I have read and examined this application and know the same to be true anc correct, a I a authorized nder Blanket Permit Agreement No. to apply for and obtain this permit. Sign lure -7 O ...--.1 Organization: �a � r. e.S N ti Print m ( o « e _ � \ e_ Phone No.: ( e (0) s is Zl z Address: 0 1,3 t0 eAr5 , 0„� ey 'e - 5, \ .k_e_ L.pg-.t7 City /State /Zip: SPco-'M- \Q. % W P ct CITY OF TUKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Tenant Improvement A • plication PLAN REVIEW NUMBER: 0 3 3 APPLICATION MUST BE FILLED OUT COMPLETELY Blanket Permit Agreement No.: -' 00Z - Will there be ANY structural work? I Date application accepted: 0 Yes FEES for staff use onl DESCRIPTION: Building Permit Fee Plan Fee Building Surcharge TOTAL' AMOUNT' • V) RCPT • DATE' If "yes ", describe' See reverse side of application for specific plan submittal requirements and information. Date application expires: / I - (� 7 "X" REQUIRED INSPECTIONS DATE APPROVED INSPECT INITIALS PLANS DATE DATE(S) CORRECTION NOTICE ISSUED X' 1. Framing 2. Insulation 3. Suspended Ceiling X 4. Wallboard Fastening DO NOT PROCEED BEYOND THIS POINT UNTIL THE BUILDING PERMIT IS ISSUED. PERMIT MUST BE PICKED UP WITHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY. Plan Review No.: , n (3' i .- 0 3 3 Date Issued: / 0 -3" - 97 Blanket Permit Agreement No.: q .? - L►o 2.. is Project Name /Job No.: Sift o t d Rey /6 h- Site Address: c7 ti 5 �1Cf o t�`e r P< V \/ CITY 61- TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Agreement Tenant Improvement Temporary Inspection Card ... . CALL FOR INSPECTIONS A T LEAST 24 HOURS IN ADVANCE (431 -3670) (Have Plan Review number, Blanket Permit Agreement number, project name and site address ready) CONTRACTOR /APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. INSPECTIONS 1 FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2 INSULATION - After framing approval, but before insulation of wallboard. Baffles must be installed to keep attic ventilation points clear. 3. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 4. WALLBOARD FASTENING - Prior to taping (See UBC Chap. 25 and Table 25G). 5. PLAN CHECK INSPECTION - Immediately after the Tenant Improvement Permit is picked -up by the applicant. Work may not proceed until the City Inspector delivers the plans and new inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. • Construction will not proceed past required inspections. • The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. • Construction may not deviate from that shown on the plans as submitted at time of application. • All corrections shall be made within three (3) days of notification by Building Inspector. • No more than 30 days shall elapse between the last required inspection and the "Building Final." • Unauthorized occupancy and /or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued. • The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. • The following work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: Electrical Department of Labor and Industries (248 -6630) Plumbing /Gas Piping King County Health Department (296 -4722) Fire Protection City of Tukwila Fire Department (575 -4404) Mechanical City of Tukwila Permit Center (431 -3670) Rack Storage City of Tukwila Permit Center (431 -3670) THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. Is any part of the work proposed under this application include structural work of affect structural components of the building? 0 Yes 64, No If yes, has the structural work been authorized by the Tukwila Building Official to be included in this application? 0 Yes 0 No Does the proposed work comply with the requirements of Chapter 10 of the Uniform Building Code (1994 Edition)? Yes 0 No If no, please explain: Will any special inspections be required per Chapter 17 of the Uniform Building Code (1994 Edition)? 0 Yes ex No If yes, list specific inspections: As a result of this proposal, does the parking meet the requirements of the Tukwila Zoning Code parking requirements? izs. Yes 0 No If no, please explain deficiency: - I Architect/Engineer Stamp: Architect/Engineer Signature: . Print Name: r_ V 11::. , r6 to 1 li 2364 PEGI,TFRED A.A.. & lir I IA, STATE OE wASMMtaTO$ Firm Name: ,..,...s., Business Phone: ei.Oti . Z•3.t3r Street Address: t t t So . J04_4.ra01.1 fir. . City /State /Zip: S✓prr"'ru. W A, g 8 t a 4 PLAN IYfl , O `=5 REVIEW NO.: ' TENANT: PROJECT NAME/ ,b IE,f r 1S'I'e4g_ �o K BLANKET PERMIT AGREEMENT NO.: *ill app COMPANY JOB NO.: SITE ADDRESS: 0 0d K. ()mpg. wes-r C V OF TUKWILA Dapartment of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 ' Blanket Permit Agreement Tenant Improvement Application Attachment 1 - Architects Statement tarr ;1( Koh • st* eE* k* kA lek ** 71c,/,e +EEkt* * /c • 1iets44k E ;kh.4eEt /c''F *: *. CITY O TUk .411LA y WA . / ` . TRANStiIT p • * e. * .6 4i 4r�r k ,.* * !c * •k F� .:E •k ;E .:t /S h.* •k /e..A •k •4 ***A . k k k k dr �k •�l'�e" A• * *• * �':t:•k k k �.4.vF•h A f .... h -h •k.,:E ; 4 � .. „ _.... .,. • ... k RHrir3NIT Number : R9 Amount: 1 33 4 '10/0E1/97 19:37 Payme nt 'Method: ;CHECK;: Notation; LOWI_ NW Ini t; ICJP Permit No D37;0335 Tvipp: »EUPCRM - LEVEI_OPMLN'f PERMI1 Par eel.. No: 2.62304 °507 .Site , Address: 545.''ANDOVER PI( : 44 `foetal Fees; 1 4.334.40 Total " ALL. rn;ts:' 14 .34.40 Da•Iance: COQ. ,. .it *# * * h,1i.*'st *•A;st ** * *A ** ih * * ** * ' * **ti* * * * k *A111 * ***h * **3•Ak303* •'Account. ,'.Code Description . . Amount 0064322.1.0V RUIL INO - : O RES 006.06 ()00 /345.fl.3Q 1?CAt� "LHI CI( NONRf:5 5`.23'i.90 600/306.5Q4 STAT'E SURCHARGE 4.50:., • COMM ENTS: Inspector: OFEMBIREMESilli INSPECTION RECORD Retain a copy with permit ' INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Date: PERMIT NO. Project: Approved per applicable codes. l Corrections required prior tq.,approval. $42,00' REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • Receipt No.: Date: , Project:.., r . � ) G4- rY:ACt.i?r)f I�C Gva -lam Type of inspections . �-t.>1 Address: :54 .5 A r o lick '•Pk. U), Date called • 11-- 19 -9 Special instructions: Date wanted: _9 ' Q a.m. �ililllil Requester: .� Phone No.: �. _ � ' (7 et2 i i J COMMENTS: I Receipt No.: , INSPECTION -RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd.; , #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Approved per applicable codes. (Corrections required prior to approval. u• h OrXe. cr'/ 7601 lam � J cry, e f- 4 ,1---- A (6 4 04-e. S!: ko /is mom' a /4344.04d 1 14' A-24 AEI Inspector /. �� / Date: $42.0 REINSPECTIO ' FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: k k; S ; :INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300' Southcenter Blvd., #100, Tukwila, WA 98188 project: Special instructions: Type of inspe 'o Date called: Date wanted: Requester: Phone No.: Approved per applicable codes. COMMENTS. Inspector: Corrections required prior to approval. PERMIT NO. (206) 431-3670 t 4 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: Type of inspection: Address: Date called: Special instructions: Date wanted: 11 11 4 0 a.m: Requester: " >r Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION n: 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 Approved per applicable codes. I Receipt No.: PERMIT NO. (206) 431 -3670 COMMENTS: i to-A-P s - P P *T- 04 t.t.N) ftrfirt . l � W c ) '- 0 .1) u ' 6 ?A4 9 A-1 t? ?r A 401-C I ' . j - . CixrVAN) Corrections required prior to approval. Inspector: Date: U $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: s. Q . f p s 10 „ ape ofip ti6n: ��� I ,� Address: c,, rr ,/ ; . l . 3 . Date called: /( ..... Special instructions: Date wanted: all a. m' Requester: tip.. Phone No.: p, . /-(o Approved per applicable codes: L eceipt No.: • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Date: PERMIT NO. (206) 431 -3670 Corrections required prior to approval. I COMMENTS: k/6 4 5 Inspector: /� n lily.(,/ Date: /7_76 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain " a copy with permit INSP NO..: . . 444. CITY OF TUKWILA BUILDING DIVISION "6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Inspector; Receipt No.: ' Project: ,. ::::2° Special instructions: Date wanted: G 7 a.m. Requester: Phone No.: ��'? Approved per applicable codes. 1 1 Corrections required prior to approval. Date: Date: PERMIT NO. (206) 431 -3670 $42.g3 FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �•� .INSPECTION RECORD • Retain. a copy with permit / 3 S I INSPECTION NO.. 4-4k. r �...< PERMIT NO. CITY OF. TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 (206) 431 -3670 Receipt No.: Projec`� .c... Type of inspectiop•� U/�rr Address: Date called: Special instructions: Date wanted: Requester: Phone No.: Approved per applicable codes. I f Corrections required prior to approval. Inspector: J $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY. . OF"TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206) 431 -3670 P,�ropject: �p a of inspec CCQnC�cu k C J •� j( ` I.�X I i \C l t'� Q � — � rS � f;31 � r' � Date caile`:1.����� --7 Q Special instructions: Date want? -�} ,a.m. ,.;� .. Requester: ��'^1 Phone No Y'i r. �1 — �o t Q1 Corrections required prior to approval. Inspector: Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. CaII to schedule reinspectlon. Receipt No.: tn C rl • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY. . OF"TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206) 431 -3670 P,�ropject: �p a of inspec CCQnC�cu k C J •� j( ` I.�X I i \C l t'� Q � — � rS � f;31 � r' � Date caile`:1.����� --7 Q Special instructions: Date want? -�} ,a.m. ,.;� .. Requester: ��'^1 Phone No Y'i r. �1 — �o t Q1 Corrections required prior to approval. Inspector: Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. CaII to schedule reinspectlon. Receipt No.: Project., _ � 5 p_ ,Type of inspe Iii i . (-VC/LA/WI • Address: s s A a J , ,/ . w , Date called: Z-- Special instructions: Date wanted: /U p.m. Requester: � � Phone No.: 9 , 7 s_, (o (Acs ( INSPECTION NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, , WA 98188 Approved per applicable codes. Receipt No.: INSPECTION RECORD Retain a copy with permit 1' 6 33 3 PERMIT NO. (206) 431 -3670 COMMENTS: 6 ^� Date: /Z , Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Adires� 545, ANDOVER 'Su i e ` enan.t " Status ISSUED` Tvp.e DEVPCRM Applied 10/081:19 Parcel. 2E 304 =.9075 Issued. .10/28/1997 *• k. A* k k..- A' k: k**• kk* k*'* k- A***.****- k'' k.- k*'** kIvk:*• k•**'A* k****** 4k*** * * *'**.v * *. * **.'k"*. P.er Co.ndi ti Na changes wi l:1 he . made,. to the .;plans unless. approved by the:. Architect Or'. Engineer a »d the Tukwt la:...8ui l :ding Divis Electrical :,-permits: shall A be `�obta :ned ;tht o.ugh the' Washing Mate; .Division of Labo :,an'd Industrie7.; an'd Fall ,electrica.1 1 1 ' be inspected by that agency (248 6630), Al:'l mechanical ,wor,i she;1.1 be a »der separ ate •per ni.i t he City of ,Tuk la l i permit, i .wi ln spetyiun. `re cords,, and approved plans avai ladle <.W the :job. 'site, ,,prior • to the start of `any str:°ucti`o ti >r. r. These docume•nts ;are ' to he maintai an able until f ina'l: inspect.ion ' appr' a va:j, Is gr At y » {,v' ei :,1 ing gs x id and,, 1`rght fixture Installation i required to_meet l.ateral- bracing r equirernents .for Seisiui Z9,ney ,ti Partition wal ls.;' atta'ctfed to ceil ing grid muSt be 'later._ally br�aceti ::If „ otter "eight CL')" feet: in ile,ngtn. • Al . ::l4,constr uct ion,.to be aorta `in;_ confor;mance with appr ov "ei p:la`ns and gipr,enten.ts 'of the Uni'forni Sii:i pii Code , 99 (•14 `f : Ed it`i on),„ a .4 amended. Un l form'. Mechanical ; Code (1994 Edition) and - Washington ,ate En er.gy :'C.ode.(1994 Va;1�i�1ity +'of Permit - : . - Th' issuance. of‘`a" permit or approval o pla'ns;.. specif d 'computati-ons all not be; con ;5 "true`d` a,,per mi't``for , :or an ap ir :. a.l` iif, any violation. of atiy,, o : ',t:he pr ~ov.isions of the 'hutldtrig code' a ».v other<<''ordinance': :of the :jurisdict:ion ;: presuming to gIVe'a'tthorit:j+ to violate or cancel the provisions code •st'al V' be valid'. -There 1 . be no occupancy of , ,the building(s)' .unt i 1 the final; irts+pectio had;tb:een completed: by'•'th'ey .Tukwi la, Building' Inspector;> 10. VENTILATION IS REQUIRED FOR ALL NEW ?QOM' AND SPACES OF NEW: • OR EXISTING.T:BUILDI•G'S IN CONFORMANCE. WITH THE UNIFORM'-:';';' BUILDING.CODE,'..AND` THE WASHINGTON :'? +;T,ATE''.VENTILATION.:•AO .' INDOOR AIR OUAL'I T'r .CODE , CHAPTER 51' -13 WAC . Sprinklers: .J Fire Alarm: M/° igs ADP' Hood & Duct: A/ Halon: Monitor: Pre -Fire: Permits: OH/( Authorized' Signature FINALAPP.FRM City Of Tukwila Fire Department TUKWILA.FIRE.DEPARTNENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued F,d John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. 1) -i C /7 - (9 3.Sr Suite # 1 T.F.D. Form F.P. 85 ///2.9 Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 4...Yi 0A614fi 116W ilmtitiivs se40 n 1 ACTIVITY NUMBER PROJECT NAME DE ARTMENT: DIVISION EI Ire/ REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED ❑ C:ROUTE -F Pe,i+ Cord Copy PLAN REVIE / R U G SLIP lopH 1.3 DA 101SI C I7 • PREVENTION C l0 15617 S UC T U RAL ❑ DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE ❑ COMMENTS REVIEWERS INITIAL DATE APPROVALS OR CORRECTIONS: (ten days) DATE REVIEWERS INITIAL DATE ml PLANNING J LANNING DIVISION ❑ P R rI MIT COORDINNA OR 1 DUE DATE 'b I Iy NOT APPLICABLE ❑ TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF [1 (If routed by staff, make copy to master file & enter Sierra.) DUE DATE wiali et 7 APPROVED P1 APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ DUE DATE APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Certification of occupancy required. ) ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION III PUBLIC WORKS DETERMINATION OF COMPLETENESS: (T,Th) - COMPLE COMMENTS ' PLAN TUES /THURS ROUTING: PLEASE ROUTE ❑ ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) 1°0 REVIEWERS INITIAL 1 1 APPROVALS OR CORRECTIONS: (ten days) APPROVED ❑ APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F ;rAtiVIALMS7.02 ,.'13'a IOM IAA; gvIEo SLIP 033 DATE IOII 7 Lo_ •4111M All NOT COMPLETE ❑ NOT APPLICABLE ❑ FIRE PREVENTION ❑ PLANNING DIVISION STRUCTURAL 0 PERMIT COORDINATOR ❑ REVIEWERS INITIAL Nbti. �' 4i�' i' t? �'.'! �§ 4". S�f•} SS# �'. Fi'' t1i' t' �. �1iR :'4?i�3S�'f�'�t.';F}"�7Vt.��, u.. -, ' 7..e.;,' � "k+i S' +•, uv;`�Sry3:�4'Ofv.- :.. . DATE CORRECTION DETERMINATION: APPROVED 17 APPROVED W/ CONDITIONS F DATE DUE DATE 'O 1141 NO FURTHER REVIEW REQUIREa DUE DATE tops') 417 NOT APPROVED (attach comments) ❑ DATE VI) DUE DATE NOT APPROVED (attach comments) ❑ (Cerdficadoa of occupancy required. PLAN REVIEW / G SLIP .ACTIVITY NUMBER p 1 � aR 33 DATE lolsici7 PROJECT N 5londar iteler DEPARTMENT: BUILDING DIVISION 0 FIRE PREVENTION i PLANNING DIVISION El PUBLIC WORKS ❑ STRUCTURAL C PERMIT COORDINATOR Q DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE COMMENTS • • TUES /THURS ROUTING: PLEASE ROUTE d NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED El APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F CORRECTION DETERMINATION: REVIEWERS INITIAL t 5 DATE NOT APPLICABLE Ej 1 ouEoA,E 10 114 l97 1 1 DATE Ay/S/9 7 APPROVED APPROVED W/ CONDITIONS fl NOT APPROVED (attach comments) 0 DATE DUE DATE Iola') ff 7 NOT APPROVED (attach comments) Q DUE DATE (Certification of occupancy required. ) ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION Cl PUBLIC WORKS ❑ DETERMINATION OF COMPLETENESS: (T,Th) - • COMPLETE ❑ COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE ❑, NO FURTHER REVIEW REQUIRED, ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED I I APPROVED W/ CONDITIONS ❑ REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F PLAN gVIE SLIP 1 � 33 DATE 1ol�' 47 CORRECTION DETERMINATION: APPROVED I APPROVED W/ CONDITIONS OA•a !AIN II Ike FIRE PREVENTION ❑ PLANNING DIVISION STRUCTURAL ❑ PERMIT COORDINATOR ❑ NOT COMPLETE ❑ NOT APPLICABLE DATE PD DATE DATE 1 o,Eow,E io�Wl�'i DUEDATE Io a1 q7 NOT APPROVED (attach comments) ❑ DUE DATE NOT APPROVED (attach comments) ❑ , (Cettificadoe of occupancy required. t !G'a* s"tr2Y'X?'Sal.W.t roe alivekt'01Pe EC kYti� R x : PLAN ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION EJ PUBLIC WORKS II q�o SLIP 1 r33 ' DATE 10141197 ar .411111 aIlke DETERMINATION OF COMPLETENESS: (T,Th) - - COMPLETE n COMMENTS REVIEWERS INITIAL (Us DATE 1 `O c i APPROVALS OR CORRECTIONS: (ten days) APPROVED Ell APPROVED W/ CONDITIONS ❑. REVIEWERS INITIAL DATE CORRECTION DETERMINATION: APPROVED APPROVED W/ CONDITIONS rj REVIEWERS INITIAL C:ROUTE -F FIRE PREVENTION E PLANNING DIVISION' EJ STRUCTURAL El PERMIT COORDINATOR 0 DATE DUE DATE ioI 1 4 r9 s 1 NOT COMPLETE NOT • NOT APPLICABLE n TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) DUE DATE 1Of ast 1 7 NOT APPROVED (attach comments) El r DUE DATE NOT APPROVED (attach comments) 0 (Ceraficadoa of occupancy requtxcd. Fire Department Review Control #D97 -0335 (512) Re: #1) Dear Sir: .urrawew+nr+*etieae..iawk+9.a City of Tukwila Fire Department Thomas P. Keefe, Fire Chief October 15, 1997 Standard Register - 545 Andover Park West (Building The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 .4r'.M�:uWnW ...S:.it. F.w ifS!^YZGYin): lo x% City of Tukwila Page number 2 • wa wMrds∎•••∎• anx••V 010.1 Fire Department Thomas P. Keefe, Fire Chief Maintain fire extinguisher coverage throughout. 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1 - 1212.8) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group 1, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 When exit signs are required by The Building Code (see U.B.C. section 3314(A)), additional approved low level exit signs which are internally or externally illuminated, or self - luminous shall be provided in all interior exit corridors serving guest rooms of hotels in Group R, Division 1 occupancies. The bottom of the sign shall not be less than 6 inches or more than 8 inches above the floor level. For exit doors, the sign shall be on the door or adjacent to the door with the closest edge of the sign within 4 inches of the door frame. (UFC 1212.6) Hallways in your building are constructed as one -hour rated exit corridors. In order to maintain this one -hour rating, doors leading into the corridor must be kept self - closing or the door hardware must meet certain criteria of the Building & Fire Codes. Please contact the Fire Prevention Bureau at 575 -4407 for further information. (UBC 1005.8.1) When two or more exits from a story are required and when two or more exits from a room or an area are required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Current supply to one of the lamps for exit signs shall be provided by the premises' wiring system. Power to the other lamp shall be from storage batteries or an on -site generator set and the system John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone :: (206) 575.4404 • Fax (206) 5754439 k: H" d: iS' tCt` i�2.:' .'?,�kii�..`1 City of Tukwila Page number 4 Fire Department Thomas P. Keefe, Fire Chief shall be installed in accordance with the Electrical Code. (UBC 1013.4) Exit doors shall be maintained in accordance with Section 1207. Exit doors shall be maintained in an operable condition. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112. (UFC 1207.1) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. An approved manual fire alarm system is required for this project. The fire alarm system shall meet the requirements of the Americans With Disabilities' Act, chapter 51 -20 WAC (Chapter 31 Accessibility), N.F.P.A. 72 and the City of Tukwila Ordinance #1742. In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S7S•4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 5 All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) When the control panel is located inside a room', the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 4404 • Fax (206) 5754439 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax: (206)5754439 CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL Pol D A T E : I0'' I r PLAN CHECK/PERMIT NUMBER: ' - 1 l -. OD 13th � ,,- �-.J PROJECT NAME: 61 /14601 i 1 ' P" 1 * 1 DDie" O he -. PROJECT ADDRESS: oi4h(e4iter arr. c . ,., n,. 5 45 f t 1C(oVe( Pi le-PJ. 4 wt tci `,VISE CONTACT PERSON: f'o v i Arse/ PHONE: 4* • 57' - 2(20 REVISION SUMMARY: • 1A 'boor 5a'' 4e, revI4eldts 1A - moo(,'I• olm»vo 2- Meth • ' etee`rl ;: ,? rant $•04> 5ataidt, Ufettete C mow& aot,e,T irt A fiek reteuturiA ct LiS1 fi)c-t2ors TPA • .eP,ea� t (efr4 vi t> SUBMITTED TO: SHEET NUMBER(S) 1-0 TA r 1 , TA --2, TA ', TA - I "Cloud" or highlight all areas of revisions and date revisions. OF TUKWILA OCT 1 k 997 PERMI TAR scoria 3/19/96 L DETACH TO DISPLAY CERTIFICATE_! STATE OF. WASHINGTON 100A torn 3'X MATCH EXIST. HT. 1 -3/4' 0 HW -1 'SCWD 5T -1 WOO) ST -1 RATED DOCR/ELEIE/FRMIE •'v MATCH EXIeT. HT. I -3/4' A HW -2 SCUM 5T -1 WOOD ST -1 102A 102B I04A E STING EXISTING EX1S11NG EXISTING EXISTING DOMING EASING y XIS11N0 EXISTING CASTING EXISTING E%151190 E1SS1NG EXMNG 3'X MATCH EXIST. HT. 1 -3/4' A HW -3 SCMO ST -1 NOOD ST -1 105A 3'X MATCH EXIST. HT. 1 -3/0' B HW-3 SLIM/GLASS ST -1 9000 5T -I 1056 Ek75TING RELOCATED DOSING EXISTING EBBING EASING D051000 E)6SiNG 10 BE REUSFASEE TA -1 107A 3'X MATCH EXIST. HT. 1 - 5/4' B H SUM/GLASS 5T -1 *000 5T -1 078 EXISTING RELOCATED E%151NG E%1511NG ECO51NG EXISTING - EXI5100 EXISTING TO BE RE05EO:1E TA - ..sr' r6.�l... � � ���// 4 .�MINI .� �� WWWm����W ac : S - 1 .uu'�_ .tIG\ 110A 12A 1 SCWDAUSS 121R0019 ®- - C T • . Yf __ I i iT. TO 8T. RE05EFXSEE TA -1 3'X MATCH EXIST. HT. IMEMICE. 50110 /GLASS En WOW En 113A E515150 RE)OS r LOCATED u, �d E H W-3 l� �.�� DGOR/0EL1E IS EXISTNG TO BE REU`0r SEE TA -1 174A 3'% MATCH EXIST. HT. 1 -3/4 A H SCW9 ST -I WOOD 51-1 115A 3'10 MATCH EXIST. HT. 1 -3/4' C HW -1 5CW0 ST -1 W000 55-1 RATED 000R/ROME/SRAME RATED 000l/REI11E/TRAME 116A EXISTING EXISTING EXISTING ER51110 01051160 EXISTING Abbreviations AC Gc AFT Mum ALl nom klum Arm Bldg m'1a n Bend Cec Ch Cig CL wu CCP Col Cone cane Cent Cana card CT Wt Wt Dim Dim On Or Deg Ea Dec Elev En Eg Exist m Fn Fir Flux FOIL Ft F10 Fum Ca WN 0 HCCW Hd Hew Hot HM Ht HVAC In Ivan Ind heal In11 dl It ' Ltg Mat Rex Meh Med Mezz Mfr Mix LIM 115 MB N/A NC No Nor Non Comb NTS 0c COO O,rg Perm Perry PI P -Lam Pd Pd PR Prop Pt RD Reh Rent Reg 'd Rev Rm Po Pub 5ched SCW Seal Sect Sht SM s al St! Sty P Tel Temp Thermo Typ Ver Ve V Vert Vwc W/ w/a We Wd U.N.O AA Cm6tionmg Smartie,' Celine lie Aa starie /cootet 01,0.. to Mow Mini.. floe Aluminum Angle Anoeved Appronmately At Budding Moping Bean BuW g Standard Bammmt Cobnel Orculatim Clear or Clearance Ceang Centerline Close Concrete Mo., Wit Contract Proposal Ceumn 1 Column or Concrete Construction Continuous Coordinate Coordinate Cara Ceramic ore Dead Diameter Dimension Down Door Drawing East Each Elevation (Height) Electric Devotion (new) Elevator Enamel Equal Eriaing Factory Finish finish Floor Fluorescent Fum 110,6 by Omer IFoot by Contract« Foot/Feet Furnished by Tenant Installed rnish /T Co u, i ingFurnish/Furnishings Gauge Galvanized Moss /oozing G49,um wall Board Hollow core Woad Hard Hardware Horizontal Hallow Mete Height Heating, Mentfling, Air Conditioning Inch Incandescent Include Insulation Installation Junction Box Joint Kitchen Lo Lineal Fool Lighting Matelot Maximum Mahonial Medium Mezzanine Manufacturer Miscellaneous Mounted MatedalMelal North Not Applicable Not in Contract Number Nominal Nan Combustible Not to Sate W Cater Opening Opposite Original Permanent Perpendicular Plate Plastic Laminate Pl Pd hW Pair Property Paint Rad'as Reliant Base Refrigerator Reinforcing Required fled ion/Reveee Roue Rough Opening Rubber South Schedule Sdid Care Wood Sealant Section Sheet 5imdar Sheet Metal Square Standard Steel Storage Suspended Telephone Tempered Ih0.001d Typical Vales U�iComposiDan Tie vented any Wall Covering West/Walt/Wdth With Without 60111000.04 Wood Unless Noted Otherwise L\ Door Schedule DOOR DOOR 00018 000! NUMBER SUE (8 X HT) 1H1(. TYP'� HDMIE Hardware (Intent is to match new hardware to existing Building Standard type and finish.) Mfr: Yale Finish: Polished Chrome No. Description NW 1 NW -2 HW -3 HW -4 Hardware General Notes: 1. IF EXISTING DOORS ARE REUSED, ALL EXISTING HARDWARE IS TO BE REPLACED AS REQ'D TO MEET ADA AND BLDG CODE ACCESSIBILITY REQUIREMENTS. General Notes 1. Refer to bask budd09 peci9colbne, requbernmb and standards far existing shell and core construction. 2. for the purposes of this work, the following definitions apply. u Owner: 1),!) Manage: Run Greene0 Inc Contractor SCA Architect; 11861 3. All work shall conform to applicable current Federal, state and Local Codes. The Contractor is to proide for dl required notification of and coordination with City and Mote agencies, and prodd0 required permits for !nested hare contractor. All tests and inspections enunciated rah obtaining approwis to proceed with and complete the work shall be paid fa by the Contractor. 4. The intent of the Contract Documents le to Indus all labor and materials, equipment and transportation necessary or reasonably infera1e as being necessary for the execution of the work. By submitting a proposal, the Contractor represents Nat thorough examination of the site and all existing conditions and limitations have bean mode end That the Contract Decummb have been examined In complete echo, and that It is determined beyond doubt that the drawings, specifications and existing NM conditions arsufficient, adeq ale and satisfactory for adjustments at no added epene to the Omer. Mere such minas construction of the wok. Nbem minor adNstmma to the week ate necessary for the Purposes of fabrication and Installation of items, or resolutions of conflicts between Neva, within the Intent of the Contract Documents, the Contractor hall make such 048010 nis affect functional or aesthetic design of the work they shall be submitted to the Owner in writing for ran and approval. 5 The Contractor hall amdbate all operations with the Owner, including area for work, materials daage, access to and from the work, special conditions or noisy work, timing of mark, Interruption of mechanise and electrical sent. and relocation of misting equipment casework fixtures. fittings. etc. Noisy or disruptive work shall be scheduled at least one (1) week in advance of the time work is to commence 6. All work hall be performed in accordance with the highest standard of wod.onshlp In general and with such standards as ore specified. Symbols 01A - Door No. B/S Public Corridor Leverstyle Mortise Lockset, 1 -1/2 Pr. B/S butt hinges, silencers, wall bumper & B/S closer. B/S Leverstyle Passage Set, 1 -1/2 Pr. B/S butt hinges, silencers, wall bumper or floor stop as required. B/S Leverstyle Office Lockset, 1 -1/2 Pr. B/S butt hinges, silencers wall bumper or floor stop as required. B/S Leverstyle Storage Lockset Set, 1 -1/2 Pr. B/S butt hinges, silen -ors, wall bumper or floor stop as required. Elevation Key Section Key Detail Key DOOR MATT . nrastiIMA11 � ' 006, RENNd6 7. Contractor shall adhere to all bddng standards. My changes to sane PM be submitted to MAited in writing far B. Contractor AM submit senates of all Mihes of such six red number that they repmt a reasonable distribution d m range and pattern prior to installation far Omens color approval. Contractor MP provide shop drawings and product data for owner's appro. on all speed dens raphig edam labrkalbn. 9. Find &mirk at substantial campleko shall i4ude doming d all lashed wood and giro seam during d al haimd0 surface, eh rang of all enacted awes and reamed of my pots. slang spas ., on any mdse named during the construction period IQ Cadlnn and use shall be the repan0DNY of the GC. Jh site shall he nwnaned n a dean and adely fahian. Debds and trash for all trades and detractors under GC control and for those under direct bi t mer act with O shall be removed doily. y. GC M coordinate ddiwie, pedal, site ends for all trade and contractors as required. 11. Contractor Is to verify di dimensions ad mars co site and notify Omer in writing of any discrep.des. Contractor is not to ode off droning, 12. Contacts shall prodder 18 -gage shat metal boding in partitions far dl w4l -mooted fixtures and decree unless Indicated otherwise on the drawings 13. Al floors should be 1021 and not wry more than 1/4' in 1tl -0 °. The Contractor shall be respans1le for correcting my candilians that do not Died this standard. 14 Fla finish transitions shall acs under doors. unless Won or noted eh0wne. 15. A0 make). indicated to match adding hall do so with respect to im, shape. cola, texture, patter, quality and method of Indonation Insofar as protkoble end shell be approved by the Owner before um.. 16. All fnproofing disturbed during demd900 or construction shall be replaced to match original fire protection levels Room No. A Revision Key Fn. Match Existing Match Existing Match Existing Match Existing Project Contacts: Ric Anderson 1/0e President Lowe Enterprises Northwest, Inc. One union Square 600 University Street, Suite 2820 Seattle, VA 98101 Phone. (206)623 -0200 Fax. 12061623 -0600 Ron N. Greene Chief Engineer Lowe Enterprises Northwest, Inc. Phone (206)575 -2120 Fan 12061575 -1198 Shawn Plckerill Project Hanger NBBJ 111 South Jackson Street Seattle, Va 96104 Phones (206)223 -5555 Fax. (206)621 -2301 Door Types DOOR WD1H AO TYPIC/L OFFICE SCW 000R- MATCH EXIST. WOOD DOOR )R. 8' -S - MATCH DUST. DETAILS U.N.O. Door Standards (Typ. U.N.O.) 000R 46011 17. Protect pommel. Pother passersby. aapants of 0d0ing balding C dears to the site from halm and Nay. arefully maintain and protect maemm4, bench mob and their reference point from being destroyed or disturbed replete as needed. 16 Exiting wok darnoged as a remit at work done under thin Contract dud be repaired to Aid median and aniehed to match adpcmt finishes, subject to Dam's approval. at no Welland cod to Omer. AP replacement matelots 184Red to etch adding modeles shell do 0 reaped reaped to type, p so pollen, texture, sae shape, odor and method of installation nef0 as practicable, and sitar be approved by the Architect and Omer prior to netdlatlon. Existing materials whkh are to be ranond may be used for the patching. but only with ewrm pprodd of the 600hllect and Omer. 19. MI misting mechanical and electrical equipment end services disrupted a removed doing 0.0905. del be restored and replaced unless noted oameis. Where existing plumbing !M em me removed, cap the supply wet and drains above 6600)1.9 and below the Soar, and path openings. Remove fillings from walls and patch openings to accommodate the new rewired finish. 20. Installation of mechanical, decided and structure spleens NI reqube opening of some existing wogs, ceilings or flit cavities. The Contractor shall be responsible for the repair of these pilings to match existing, except where noted 019,1900. Fit dl holes and weds In 0a, wale and clings which result from Mediation of work and removed of exol1g materials and equipment rewired by this Contract. Patched areas shall match the material, iNihes. and Wets adjacent as hall be put In the proper condition to receive the finish ndldled 21. Shop drawings shall be submitted to architect (4 copies) for review. Shp drawings enhance these specifications: weasel of walled drawing, shall not release contactor of responsibility for shoo cm 22. Warranty shall be extended far all construction components and equipment and 100101lalbne Included in this work for o minimum of 1 ]ear from dale of substantial completion. DV- 0 MIN. AT PUSH SIDE MIN. AT + IF DOOR PULL 885 I SIDE CLOSER RUBBER BASE TYPICAL NON -RATED OFFICE DOOR W/GLASS INSERT. MATCH EXISTING DOOR M. B' -S 21 Openings required for new wade that penetrala adding structure hall be comdnaled with Omer prior - to dlnmpeng the work. My opening ow 2n' Onsets shall be redewed and approved. by Omer. 1Mau4h existing Pea structure et wd, or masonry wob, d round hales shall be acre drilled with a dimmed drill and all r /004460 oping, Mall be at 9Nh a diamond car In d rase dud my structural mambos be ad, Use bide - tipped dale far ggmm wellhead partitions. .: Ker9 avereottim to a mblnennt Maintain continuity and integrity of fire epoatian t all Ones. Goal aroma conduits Ruing through cawele wee and fide and memory. wan, Mho NOM. with mull bhesed edges: match added editing work 24 Contractor *MI profile km leveling as may be required l Siding doom, rdRea without bone cabinetwork and °Vier bedlam rewiring oral mbelrale. feather Mango in elevation ow su0Nel area to lima trandlon dope to 1/11' per hot 25. 90)064, slides, denims and products are wedged in the documents by reference to the building standards, by I109 acceptable manufacturers er products, by requbig candknee Mk referenced standard.. a by 9erfam000 petlflulies Fs ilea specified by name pled any prodse named, 1st those specified by reference standards or by perferomce specifications pled any product meeting or exceed*g specked criteria. For roved of an Ilan not specified, inborn required submittal, prwoid'ng complete bock-up information kr purpose of evddtian. Nhee building standard items are called tar, no substitute wit be aapda 26. Contactor hall provide for all *Pk required la maintain compliance with Local Fire Code. Provide for all required shop drawings and approval. All devices shall match existing systems. Contractor H responsible fa providing fire dam system adb4ily. 27. Mechanic,' and electrical futures, outlets, etc., when shown on the architectural dawinge, are for locution iniama9m only Mechanical and electrical to be dedoued by others All dredging cadnation to be by others. Location Map 1/4' TEMPERED GLASS DOOR 4810 N000 FRAME VICINITY MAP N.T.S. C TYPICAL SCW ENTRY DOOR - 20 MIN. RATED & LABELED. MATCH EXISTING DETANs U.N.O. 26 Contractor is to grads trading* for amt's ad Ar6Wx0s apps,4 *dig wow«. 4t NVAC themasbsts. grin and &Mama, lire and make detection &does *000696 spr4Hes smoke detectors, are edigu5iers ad 0e base cobbnel. 29. My change in rind entire *caned de to Madera= of mechanical a structural ear pomets mall he 96400006 by the Ar hilect 30. Carpet SbmiT aeon* drawings showing carpet outs are rewired. 4hdft - emplo ask mplde mmubhrds r«mmme0uam and PP naMbg crunch d code amplimae heel In acord.= all mandated. redenmend0llmc Prdds bddee edge sign Loy wig swans pord4 to long *modal of read. IIPIM Malian at pattern and texture. Cater mono under doare. Do not Flom assns in traffic *alien In doorways as amides Gem carpet at completion d work Proide protective mmHg Preside all finish aaawerim Furnish man1omoe information. Return d surplus of practical Snead. to tow. Provide for follow-up ad smart unto. 31. Prier to short 040.90006. 0C hd daranee scheduling of meeting with Ms project personnel, the buidng/landas06 rep(s), Omer pm9et trimmer, others fo review of po)el scope, design intent cansbuclice quality tweeted, and Tad Maeda of drawings/ drab /queelbn, 1/4' WIRE CLASS MITE 11 WOOD FRAME ICH 1/2- X 3/4 (WI) CONT. METAL ANGLE STOPS ALL AROUND BOTH SIDES. NOTE NAXNUR cuss AREA OF ANY ONE PANEL NOT TO laCEFD 1,296 50. INCHES MUM STANDARD SIGNAIE 20 -MINUTE RATED BUILDING STANDARD DOOR PANEL IN 45- MINUTE RATED E00R/REITE FRAME ASSEMBLY (ALL UJ_ LISTED AND APPROVED FOR 1 -HR PARTI110N) BUILDING STANDARD PUBLIC CORRIDOR BASE Special Notes 2. APPLIANCES: A. Full -size Refrigerator. N.I.C. Legal Description m t cer �ec �A the Cky TWnb, Centy M IAg R0 rt s T G R.t4 V. fi ord beep 2 t�M W t�ezt 1/e of tM ...abed as r A gawer 1M msMrly 01 369311 et fr. the 0 07west 0 o'r N corner 4 ,10N• miner ore 12 1 P STAAGVal. 8 0 " E r �lige N lmanrd II wepterlyd' v'np ireeeteMagimbal o f ee M arc I lengthMJ61 y ieet re N s a o o i l utl a line that po mhe is porde-an dN. ...M 4 0006...., 1 of t 'r V satl Dist iyd 110009 plmg .1 red drdlel ins 1 1006 0 29'E .rO y o f M 'Sr pin a '..4`1.' ter ple to a ltg M hp& 365A0 let southeNy tlx at W,rr �m t h uf m epst t l l Na /'d 1 M ae l plo� l e lpat mUWl U m • ParMIN I�X,e e 42'V YYff b yy e 0 g % Po amt0 e n tmf 5 s dea h NN'IYZA' 2 oi 6 4 iB ec M o r SBB'a5'42E 206L0 i t . P M NT SEMNING arelta p 1.408 aches air led more . less Index TA -0 COVER SHEET TA -1 DEMOLITION PLAN TA -2 CONSTRUCTION PLAN, FINISH PLAN TA -3 REFLECTED CEILING PLAN TA -4 POWER & COMMUNICATION PLAN TA -5 DETAILS 1. The Design Intent for this project is to match existing Building Standard details and finishes, Field Verify, and notify Owner of discrepancies or conflicts between architectural details and existing conditions prior to construction. .,ndersiand Thal the Plan Check Opprnv0IS ere ..,...; Oct to errors and omi,einn,4 and Opornvnl 01 not authorize the 9010110h 91 BnV y'ol sal code or ordl e. Receipt of 001, t /aatc i s copy of apprguie piens ocknnwleriQnd, By Date Ia ?A 7"7 Permit No 0535 SEPARATE r' REQUIRED ti EMECHA' G ELECTRIC: PLUMBING ❑ GAF PIPING CITY OF TUKV10'L A BUILDING DIVISION Agency Address: Building Code: Construction: Fire Protection: Occupancy Type: FILE COPY Notes 555 Andover Pork West Tukwila, Washington 1994 UBC 1m Sprinklered 8 Office NBBJ £ c i"1 - 0335 111 South Jackson Street Seattle, Washington 98104 12061 223 -5555 Fax 1206) 621 -2300 LOWE ENTERPRISES NORTHWEST, INC. STANDARD REGISTER Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 10 13 DP DOOR SCHED.REVISION A 10-09-97 DP DOOR SCHED.REVISION 1 10-01T97 DP PERMIT SET Wizen Date By Deew9f n of Ration Sheet 1060 COVER SHEET Sale 1/0' = P -0' Designed Dom 10-01 -97 Approved By Rat Nabs c17-00- EPA TA -0 RECEIVED CRY OF TDHWIIA OCT 1 41997 . ERMIT CENTER OM. PRO Checked BP Job Nubs 40951.09 1/8" = 1' -0" DEMOLITION PLAN ii L ii NOT IN SCOPE LIMIT OF WORK !<' Dq1- 0335 NORTH A CODED DEMOLITION NOTES: O ROUND BI-1OD DOORS AND SHELVES TO BE RELOCATED AND REUSED N OFFICE 1107. EASING SINK A10 CABINETS TO REMAIN. USING ODOR AND 1001E TO BE P01000TED AND REUSED N CONFERENCE ROOM 1112 REMOW: WALL 11 FRONT OF F70S1110 11114001 DEMOLITION NOTES: 1. ALL DOMING EDNMENNT TO BE SALVAGED; DOORS, 11001ES, FRAMES CASE1DRI( FIE EXINdAOIER CABINETS, LIGHTING, ETC. EI05T ITEMS REMOVED AS REQUIRED ARE TO BE REUSED ON RETURNED 10 OWNER. CONTRACTOR IS 10 COORDINATE MOMENT AND STLWAGE OF SALVAGED. 2 EA51110 DOORS ARE TO BE RETAINED AT THE LANDLORD'S 0110X. BEFORE CO MBICING MTH NMWDON. INSPECT 00511NG DOORS 411H 111E BUILDING ENGINEER AND 1101E TH010 MACH MILL BE RETAINED. 3. VERIFY 000140 CONDITIONS PRIOR TO 0E0OITON AND INFORM ARORIECT OF ANY DISCREPANCIES. ISSUES OR CONFLICTS. 4. AL DEBRIS REMOVAL 941 BE PERFORMED IN ACCORDANCE MTH OWNER'S RE0ANIENTS AND PROCEDURES 5. FASTING UNUSED OUTLETS AFFECTED BY PROPOSED Da,10U1ON TO BE REMOVE AND CONDUITS TO BE ROAMED AND CONDUITS TO BE TED BACK TO BUILDING ELECTRICAL PANEL D0 NOT ABANDON CONDUITS IN PLACE. E GENERAL CONTRACTOR TO REMOVE HEMS CAREFULLY; ALL ITEMS DAMAGED DUE TO REMOVN. 941. BE REPLACED AT THE CONTRACTOR'S EXPENSE AND M1114T ANY COST TO BURL NG OME R AND TEN/111. 7. FILL AL HOES N FLOOR ERIE INSTALNG FLOORING. E PATCH AND RENE ALL EFFECTED AREAS TO MATCH EDSTNO 9. CC SHALL 0EDOU91 DOSTMC0 PARTTO1 MD VAADUS OTHER RENEWS AS 11DNN1E0 ON PLAN AND COORDINATE THE REMOVAL OF AL RELATED ELECTRICAL ORMCE PUIYBRNG AND AL OTHER ASSOCIATED SERNCES N CLIIOFO. AS REMOLD. 10. GC 941 BE IESPONORE FOR THE IE110VAL OF ALL CO151RUCT0N DEBRIS AND FOR THE RETURN OF ANY MEDIC STANDARD COMPONENTS IF REQUESTED TO HE BALDING MANAGEMENT. 11. RETOOK ACOUSTICAL CBIRO TILE THROUGHOUT CONSTRUCTION AREA AND SAVAGE FOR REUSE LASTING CEILING LAID TO REMAIN. RECORD HOOT M0 PORTION OF GRID. REPORT ANY DISCREPANCIES FROM THE PLAN TO THE PROTECT ARCHITECT. 12 EOSTNG ELECTRICAL WHOM RETIRES TO BE RETAINED FOR RDNSTALLATON. PROTECT STORED FEMMES FROM DAMAGE DURING CONSTRUCTION. 13. REMOVE ALL ELECTRICAL CARING AN0 DEUCES REFER TO ELECTRICAL PLAN FOR 001010IGI COMPONENTS MACH MAY BE RETAINED. NOTE: 00 NOT REMOVE LOW-VOLTAGE 111/AC CONTROL WRING. 14. REMOVE ALL FLOOR FINISHES WTHIN THE SCOPE AREA TO SLAB. CREW SLAB 10 A SMOOTH SURFACE READY FOR APPLICATION OF FINISHES. 15. REMOVE ALL CASING CABINETWORK AND FINISHES WIHIN 1HE DEMISED AREA. (10 APPROVED, CABINET TO RENON BY TENANT.) DEMOLITION PLAN LEGEND Symbol Description E105TNG PARTITION TO BE REMOVED E450NG PARTITION TO REMAIN CITY OF iiiNi IA p,PPFO OC1 23 NBBJ 111 South Jackson Street Seattle. Washington 98104 12061 222 -5555 Fax 1206) 621 -2300 LOWE ENTERPRISES NORTHWEST, INC. STANDARD REGISTER Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 10 -09 -97 DP DEMO WALL REVI5ON 1 i0 -01 -97 DP PERMIT SET Mirka Dote By DuwDtion of Reidws Sheet T159 DEMOLI110N PLAN /Legged Rex9 ONP Dote 10 -01 -97 Checked BP *cored By Job Raker 10951.09 940 NrtAe TA-1 CT' OCT 1 4 1997 PERMIT CENTER No. Name Remarks CPT -1* CARPET SHAW, PARALLELS, BLACK DIAMOND #64560 CPT -2* CARPET SHAW, SHOAL CREEK 0, 30 oz., CLASSIC GREY #19576 RB -1* BASE ROPPE RUBBER BASE, #50 GRAY VCT -1* VCT ARMSTRONG, INSPIRATIONS, #401 WHITE MULTIFLEC PT -1* PAINT BUILDING STANDARD, OFF - WHITE ACT -1 ACT -1 ARMSTRONG SECOND LOOK II; EXISTING TO BE REUSED. ST -1 STAIN TO MATCH EXIST BLDG STD WOOD STAIN IN COLOR & FINISH PL -1* _ LAMINATE WILSONART, #4622 -60 GREY NEBULA WC -1* WALLCOVERING KOROSEAL GOSSAMER BASICS, #7003 -08 CROSSWINDS Symbol Description Floor MIL EXISTING WALL TO REMAIN North Walls South NEW BLDG STD PARTITION TO ACT, SEE DETAIL 13/10 -5 West CeiH g MAL NEW 5' -0' LOW HEIGHT PARTITION W /WOOD CAP, SEE DETAIL 11 /TA -5 100 Reception NEW 1 -HOUR RATED BUILDING STANDARD PARTITION, SEE DETAIL 12/TA -5 08 -1 Room No. Name Floor MIL Base MIL North Walls South East West CeiH g MAL V V Remarks 100 Reception Cpt -i 08 -1 PT -1 WC -1 WC -1 PT -1 ACT -1 4 ALL FINISHES TO MEET CLASS "A" FIRE 101 Mail /Copy TACT -1 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 SPREAD RATING. 102 Open Office Cpt -1 RB -1 PT -1 PT -1 PT -1 00 -1 ACT -1 103 Training Cpl -1 RB -1 PT -1 PT -1 PT - 0T -1 ACT -1 104 Parts VCT -1 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 105 Office Cpt -2 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 106 Open Office Cpt -1 RB -1 P0-1 PT -1 PT -1 PT -1 ACT -1 107 Office Cpt -2 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 108 Staging Equip. VCT -1 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 109 Locked Storage VCT -1 RB -I PT -1 PT -1 PT -1 PT -1 ACT -1 110 Office Cpt -2 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 111 Cust.Engineering VCT -1 R8 -1 PT -1 PT -1 PT -1 PT -1 ACT -1 112 DSM Office Cpt -2 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 113 Conference Cpt -2 RB -1 PT -1 PT -1 PT -1 WC -1 ACT -1 114 Electrical Rm. VCT -1 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 , 115 .arridar Cpt1 RB -1 PT -1 PT -1 PT -1 PT -1 ACT -1 101'. 105 1 OFFICE PARTS 1 I1IJ TRAINING 1 102 OPEN OFFICE MAIL /COPY /COFFEE i RECEPTION IA- CONSTRUCTICnI PLAN 1/ 8 " -1' 0 Al t7'11O?5 i 1 .07 1 01101 108 i ESU9' ilea 1 DSM OFFICE CONFERENCE NORTH A CUSTOMER ENGINEERING A ' \ Finish Schedule Construction Coded Notes: O BUIDRT0 SWARD WA UCOLINC O BI1LT -N P -LAN WOPo@A6ACE, 31 r 34 W/3 ML LQTGN 1rd P-IAM UPPER NTH BI -10 5NEL VE5 ON z4 STNlDAPD BtAOa: M OWED 1Y ar A N911E AQ; ENLIIFSE 10 00015 (0 51 0010 PLAN NOTES, TA-I). &ALT -MP -LAM. 91011115. 3B'd v 1 OPEN EMIL PROW( never AS REWIRED;. REFER TO ($ OETAL 14/14 - 5 30' O FULL HEIGHT WALL 4/9111WNG STANDARD WALLCOWRNG AND STANDARD REGISTER LOW (LOO) SPECNCATIOHS 10 BE DETERMINED BEIWE0I CONTRACTOR MID 1049141. O PROVIDE WATER UNE FOR REFRIGERATOR'S ICEMNO10 O PROVIDE WATER UNE FON'COFEEMAIER O BUILT N P -LAM WDNISUNFACE, 24'd A 481. O BUILT-IN P -LAM WOR1S0116f, 24'a x 481.., NTH SHELF UNLIEREAIN, in 1 3011. Construction Notes: 1. WERE DOSING I5 RETANED . 0EAN, PATCH, REPAIR AMa FWW91 TO BE EQUAL TO HEW O0M51R110119. 2. VERIFY DOSING CONDITIONS PRIOR TO DEMOLITION AND INFORM ARCHITECT OF MY ISSUES, DISCREPAIl0ES, OR COIFUCTS PRIOR TO CONSTRUCTION. 3. ALL FIREPROOFING 015TUR0D. DURING DEMOTION SHALL BE 8EP0ACE0 10 MATCH ORIGINAL FIRE PROTECTION IEUELS. MAINTAIN CONTINUITY AND INTEGRITY OF FIRE SEPARATION AT ALL IVES 4. PATCH ANO REPAIR PARTITIONS AS 6EQUIRm WE TO 1E110E1191 WOW N ENDER TO ACCEPT NEW WALL FINISH. 5. PATCH AND REPAIR FLOORS AS REWIRED WE TO DEMOLITION WORK 90M AND PREP FLOORS AS PEW TO ACCEPT NEW FLOOR FINISH. 6. DO NOT SCALE OR91NG5 WRITTEN DIMENSIONS TAKE PRECEDENCE OKR GRAPHIC REPRESENTATION. DETAIL DIMENSIONS TARE PRESENDENCE 01£R. PL.V4.OMENMON& 7. AU. DIMENSIONS . ARE TO FINISHED FACE OF PARTITION, COLUMN, ETC. UNLESS. NOTED 0110911SE ALL DIMEN1ONS MANED 'CLEW SHALL BE MNNT9NEO AND SHALL ALLOW FOR THICKNESS OF F11101 MATERIALS. 8. DIMENSIONS LOCATING DOORS ARE TO THE IN5DE FINISHED EDGE OF JAMB UNE. 9. REUSE DOORS REUTE5 AND HARDWARE FROM E0151NC INVENTORY WHENEVER POSSIBLE COORDNATE AVAILABLE INVENTORY AND ACCESSIBILTY 'MTH OWNER. FIELD VERIFY DIMn750N5 APT CONDITION OF UNITS TO BE REUSED. TOUCH UP STAINED OVER AS RE00 FOR NEW APPEARANCE. NO/FY WEIR OF DISCREPANCIES PRIOR TO CONSTRUCTION. 10. PROVIDE 16 GAUGE SHEET METAL BACKING IN ALL PAR11ON5 WHERE WALL- MOUNTED CASEWORK OR EQUIPMENT/ HARDWARE IS INDICATED. 11. PROVIDE SHOP DRAWINGS FOR NEW CASEAI7RK ITEMS FOR RUM AND APPROVAL BY OWNER AND ARCHITECT. ALLOW ONE WEEK FOR REAM. 12. ERRING HVAC SYSTEM 15 TO BE MODIFIED AS REWIRED DUE TO NEW CONSTRUCTION. ALL WORK TO CONFORM TO STANDARDS AND DIRECTIVES AS PROVIDED BY OWNER. GENERAL CONTRACTOR TO COORDINATE SCHEDULE OF HVAC WORK REVD TV/OWNER. COORDINATE NEW THERMOSTAT LOCABWS 11/IENW4 AND ARCHITECT PRIOR TO INSTALLATION. 10 ALL PENETRATORS AT ONE HOUR RATE0 PARTITIONS SHALL BE SEALED TO HAVE 111E SAME. PROTECTION LEVEL AS PARTITION. PROVIDE AND INSTALL FIRE DAMPERS AT HVAC DUCT LOCATIONS ONE -HOUR FIRE RESISTANCE RATING TO BE MAINTAINED AT ALL TIES PER ALL APPUCABLE BUILDING CODES AND ORDINANCES 14. ALL WOOD TO BE TREATED IN ACCORDANCE WITH LOCAL CODES. 15 'ALIGN' MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. 16. ALL USING AND NEW FLOOR SLAB PENETRATIONS FOR PIPING SHALL BE FULLY PACKED MID SEALED IN ACCORDANCE WITH APPUCABLE BUILDING AND FIRE CODES. 17. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE 19. ANY DIMENSION REMSIONS/MODIFICATIONS ARE 10 BE BROUGHT TO THE ATTENTION OF THE ARCHITECT'S PROTECT MANAGER FOR REMEW AND APPROVAL. Finish Notes: 1. *ERE : E0511NG 15 RETAINED CLEAN, PATCH, REPAIR, AND FINISH TO BE EQUAL TO NEW CONS1iUCPOI. 2. PATCH AND REPAIR ALL PARIPON5 AS REWIRED DUE TO DEMOLITION WORK IN ORDER TO ACCEPT NEW WALL FINISH. 3. PATCH AND REPAIR ALL FLOORS 0UE TO 018011101 WM. SKIM AND PREP FLOORS AS REVD TO ACCEPT NEW FLOOR FINISHES. 4. ALL PARTITIONS a1HIN THE LIMIT OF WORK, NEW AND 09SIING TO BE PAINTED P1 -1 (0.11.0.). 5. ALL FINISH MATERIALS TO MEET CLASS 'A' FLAME SPREAD RA1NG. 6. CLOSED CASEWORK AND DRAWERS TO HAW 91111E MELAMINE INTERIORS. OPEN CASEWORK TO TIME PLASM LAMINATE INTERIORS (SEE MATERIALS LEGEND, PL -1) DRAWER EDGES TO HAVE PVC EDGE TO MATCH ADJACENT URINATE COLOR. OPEN SHELMNG TO MATCH PU5111 URINATE. 7. PROVIDE RUBBER OR WM REDUCER STRIPS AT TRANSITIONS BETWEEN CARPET AND VCT. COLOR TO MATCH CARPET. PROVIDE A RANGE OF COLORS TO CHOOSE FROM. CONSTRUCTION PLAN LEGEND NBBJ 111 South Jackson Street Seattle. Washington 98104 (2061 223 -5555 Fax 12061 621 -2300 STANDARD REGISTER Sleet MN 5ade I/B' = Dectsed Dote 10 -01 -91 Appl0Ved By 9eet 14711tr TA -2 LOWE ENTERPRISES NORTHWEST, INC. Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 z0 10-13 -97 DP ELECTRICAL NA ADDITION FINISH 016100E SPEC5 A7 10-09 -97 DP ROOM FUNCTION CHANGE 05M OFFICE CLOSET 911VD. FINISH SCHEDULE SPECS I 10-0 -97 DP P0911T SET 11rt6er Dote 00 Deruplon of Renews CONS1RUC11ON_ PLAN ... Dean 007 Choked BP 6001500 CT'OF101241 OCT 14 1997 PERMIT CENTER Job Nsrbe 40951.09 SWnbd Fixture Wolfs x Quantity Total Watts Existing B/Std:2x Fluorescent failure to be rdocated and reused. Dabbroe Recessed. w/ 1 1/2' poracube lens typ. . 120 30 3,600 a Existing B /Sid. 2x4 Fluorescent future. to remain. Dalbrite Recessed with 1 1/2' Paracebe .lens tax. 120 43 5,160 r New 2x4 Fluorescent future to match Dalbrite Recessed. 120 19 2,280 existing. with 1 1/2 Paracube lens typ. O incandescent Building Stand recessed 75 10 750 9 New Building Standard recessed Will wash er. 75 2 150 . 1®!. B /Std. Exit Light - 6 - $D Dimmer Switch . Ex 2X4 ceiling grid w/ existing 2X4 ceiling tile to remain: Armstrong Second Leak II N/A Waite Allowed Total Watts Presided: 10,000 SQ.FT. 1.2 WATTS/SOFT. = 12,000 WATTS First Flaor.. 11,940 watts Note: 1. New ceiling tile to match existing: Armstrong Second Look II 0 Q --Tra IEEE N I 411 R R 11 • 1 1111 1 1 1 1111 1 11 N N 1 1111E11 R R [ 1 1_ 11111 111 I' 1111 11111 1 u !! _ ©U1111 11111 s 11i1!■.•iii ■■■■■ 1 1111111"'�'�1111 At - .---- - - - --, 17 1 11 NOT IN SCOPE 11 A_ EL C � 0 G J J iD M UP I UMIT OF WORK NOT IN SCOPE 11 112 06 _ o-_N OFFC; 105 I O0F1Q 104 PARTS 1 03 TRAINING 102 OPEN OFFICE MAIL /COPY /COFFEE 00 RECEPTION L. 107 a, „ 1:. 7 CDs 5-40001. E 109 1 LO00E0 STORAGE CUSTOMER 005900IWN0 009 OFFICE CONFERENCE ECM ELECTRICAL ROOM 115 CORRIDOR NORTH 0 REFLECTED CEILING PLAN OD REFLECTED CEILING LEGEND REFLECTED CEILING PLAN NOTES 1. SCOPE: GC SHALL INSTALL S080ENDED ACOUSTICAL TILE. VERIFY EXISTING CEILING GRID AND CEILING TILES. EXISTING CEILING GRID TO REMAIN. RECORD HEIGHT AND POSITION OF GRID. REPORT ANY DISCREPANCIES FROM THE PLAN TO Tiff PROJECT ARCHITECT. 2. REMOVE ACOUSTICAL CEILING TILE THROUGHOUT CONSTRUCTION AREA AND SALVAGE FOR REUSE. REPLACE DAMAGED CEILING TILES WITH NEW TILES TO MATCH DIETING. 3. CEILING PLANE SHALL BE LEVEL AND TRUE AND IN ALIGNMENT WITH ALL LIGHTING, SPRINKLER. NVAC AND OTHER ELEMENTS INCORPORATED IN ITS CONSTRUCTION. GRID SHALL BE CONTINUOUS THROUGHOUT THE DEMISED AREA. 4. PROVIDE ACCESS CUT-011T IN OAR AND TRIM AS REO'D FOR ALL LIGHT SNITCHES. PATCH & REPAIR EXISTING CAB AS REWIRED WHERE LIGHT SNITCHES ARE LOCATED. 5. SPRINKLER SUBCONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND MODIFY EXISTING SPRINKLER LAYOUT AS REO'D TO SUIT PARTITION & LIGHTING LAYOUT. 00111 8CTdi TO COMPLY W/ ALL APPLICABLE CODES AND ORDINANCES. 6. VERIFY EXISTING LIGHT FIXTURE LAYOUT PRIOR TO INSTALLATION. NOTIFY OWNER A ARCHITECT OF 01011100 LOCATIONS THAT CONFLICT WITH SMIRKERS, MECHANICAL 5YSTEM5, OTHER ELECTRICAL OR STRUCTURE ABOVE PRIOR TO CONSTRUCTION. 7. ALL SWITCHES TO BE LOCATED 0 48' A.F.F. TO CENTER OF SWITCH UNLESS NOTED OTHERWISE. WILTIPLE SWITCHES AT ONE LOCATION BE GANGED TOGETHER MD FINISHED W/ ONE COVERPLATE. LICIT SNITCHES TO CONTROL FIXTURES WITHIN THE SNAE ROOM U.N.O. 8. THE REFLECTED CEILING PLAN INDICATES LIGHT TYPE5 AND ASSOCIATED 11E16. COORDINATE CIRCUITING, WIRE LAYOUT AND ADDITIONAL INFORMATION WITH ELECTRICIAN. 9. EXISTING ELECTRICAL LIGHTING FIXTURES TO BE RETAINED FOR REINSTALLATICW. PROTECT STORED FIXTURES FROM DAMAGE DURING CONSTRUCTION. 10. CLEAN FIXTURE LENSES, REPLACE DAMAGED LENSES, RELAMP FIXTURES THROUGHOUT AS REQUIRED. 11. FINISH OF ALL 1EW SVITCPLATES TO MATCH EXISTING. 12. ALL LIFE SAFETY DEVICES Ate EMERGENCY LIGHT FIXTURE LOCATIONS TO COMPLY W/ ALL APPLICABLE CODES MO ORDINANCES. 19. ALL PENETRATIONS AT 0EHOUR RATED PARTITIONS SHALL BE SEALED TO HAVE THE SANE FIRE PROTECTION LEVEL AS PARTITION. PROVIDE AND INSTALL FIRE DAMPERS AT HVAC DUCT. LOCATIONS. ONE -HOUR FIRE RESISTANCE RATING TO BE MAINTAINED AT ALL TIMES PER ALL APPLICABLE BUILDING CODES AND. ORDINANCES. 14. PARTITIONS SHALL NOT PENETRATE THE CEILING PLANE EXCEPT MERE ACOUSTICAL OR FIRE PROTECTION CONSIDERATIONS ARE CALLED FOR (SEE CONSTRUCTION PLANS). ACOUSTICAL . =TRACTOR SHILL COORDINATE WORK WITH CARPENTRY TRADES TO PROVIDE FOR NEAT. LEVEL VISUAL LINE AT THE INTERSECTION OF CEILING AND PARTITIONS. 15. VENTILATION FOR THE ENTIRE TENANT SPACE SHALL MEET THE STANDARDS SET BY THE WASHINGTON STATE VENTILATION MD INDOOR AIR COMITY CODE FOR THE SPECIFIC OCCUPANCY OF EACH ROW. 16. ACCESS SHALL BE PROVIDED BY GC AS REWIRED FOR INSTALLATION AND MAINTENANCE OF MECHANICAL, ELECTRICAL AND OTHER ELEMENTS WITHIN THE CEILING PLENUM AND AS REQUIRED BY CONE. LOCATIONS FOR SPECIAL ACCESS DOORS, HATCHES, ETC. SHALL BE COORDINATED WITH OTHER TRADES AND APPROVED BY OWNER. AS -BUILT REFERENCE PLANS SHALL BE PROVIDED. 17. INSPECTION, AS REQUIRED BY LOCAL AUTHORITIES SHALL BE COORDINATED BY THE CC PRIOR TO THE CLOSING OF THE CEILING. 18 SHALL BE ALL RELATED AC) 0 10 MANUFACTURING AND INSTALLATION. A COORDINATED SHOP DRAWING FOR ALL VISUAL CEILING ELEMENTS SHALL BE SUBMITTED. 19. (MECHANICAL AND ELECTRICAL CONTRACTORS SHALL COORDINATE WORK WITH ARCHITECTURAL DRAWINGS. ARCHITECTURAL CEILING PLAN SHALL GOVERN WITH RESPECT TO LOCATIONS FOR CEILING PENETRATIONS AS AESTHETIC AND FUNCTIONAL CONSIDERATIONS DICTATE. MECHANICAL 000LR0ENTS SHALL TAKE PRECEDENCE WITH RESPECT TO OVERALL SCOPE OF WORK. 20. CLEARANCES FOR ALL RELATED PLENUM INSTALLATIONS, SHALL BE COORDINATED BY THE GC. NBBJ 111 South Jackson Street Seattle. Washington 98104 (2061 223 -5555 Fax (206; 621 -2300 LOWE ENTERPRISES NORTHWEST, INC. STANDARD REGISTER Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 0+ 10 -13-97 DP FIXTURE PLACEMENT /A0D'N. 1 10 -0 -97 DP PETAIIT SET Heber Dole By Dewplbn of Ramon Sheet TAM P FI,EGTED CEILING Sob 1/9' = 1' -0' Desiged Dote 10 -01 -97 Dawn OKP CIedred BP Alpored By lob Nrlber 40951.09 Sleet Nxkoe TA -3 CRY 0FE' UEKwNA OCT 1 41997 PERMIT 00)00R SALES 00.22110200001 LIMIT OF WORK I 104 PARTS 1 103 j TRAINNG OPEN OFFIC RECEPTION 101 MAIL /COPY /COFFEE POWER & COMMUNICATION PLAN • /8" = 1' -0° NOT IN SCOPE 708 11 S0AGINS E953P won SSCR1ZE 111 CUSTOVER t]NWNEESDNG n2 DSM DFFlCE CONFERENCE 114 ELECTRICAL ROOM I 115 1 CORRIDOR NORTH Coded Notes: Pg1 O OUTLETS TO BE LOCATED AT 44' A.F.F. O FINAL LOCATION OF POWRFEEO WILE TO BE DETERMINED BY FINAL FIEBHTL8E LAYOUT. AND COORDINATED WITH TENANT'S FURNITURE VENDOR.. O FLOOR IM MO TRANSFORMER, 75 VOLTS O FLUSH WALL MOWED BREAKER PANEL. 200 ALP, 120 /208 POWER Power & Communications Notes: 1. ALL WALL MOUNTED OUTLETS SHALL BE W 18' A.F.F. WLES5 NOTED OTHERWISE. HEIGHTS SHALL RE DETERMINED FROM FINISHED FLOOR TO THE WNTEBLIIE OF OOAEOPLATE, INSTALLED VERTICALLY CROWDING POLE AT TOP. 2. INDICATED DIMENSIONS ARE TO CENTER OF THE WVERPLATE; CLUSTERS OF OUTLETS ARE DIIENSIOED TO CENTER OF CLUSTER MISS NOTE OTHERWISE. OUTLETS ROAN ADJACENT TO EACH OTHER SHOULD SHOULD BE PLACED WITH MINIMAL 0IIENSION BETWEEN THEM, U.N.O. 3. CONTRACTOR TO COORDINATE ALL WOE( RELATED TO EOUIPIENT WITH MANUFACTURER'S RECOIWEIDATIOIS, SPECIFICATIONS, AND INSTRUCTIONS, INCLUDING SPECIAL RECEPTACLE CONFIGURATIONS FOR ALL COPIERS AND PRINTERS. 4. ALL NEW COWER PLATES TO MATCH EXISTING FINISH. 5. FIINITIAE 91D11 FOR IIWOEATIOAL PURPOSES ONLY - N.I.C. CONTRACTOR TO COORDINATE FINAL FURNITURE LAYOUT W/ TENANT'S FURNITURE VENDOR PRIOR 10 FINALIZING ELECTRICAL PLAN TO ENSURE PROPER: ELECTRICAL LAYOUTS. B. VERIFY SECURITY REOIIREIENTS WITH TENANT. LOCATIONS AND REaIRON:NTS TO OF COORDINATED BY ELECTRICAL CONTRACTOR WITH TENANT PRIOR TO CONSTRUCTION TO INSTALL CONTACTS AND READERS. PROVIDE CONDUIT AND WIRING (RCN PANEL TO DEVICES. P =TRACTOR 10 PROVIDE MIDSTRIN(S AND PULLSTRINGS. ALL DATA AND PI0E LINES NOT INCLUDED IN CONTRACT. 8. POWER REDUIREMENTS FOR 864 AREA5 CONTAINING SYSTEMS FURNITURE AND WORKSTATION5, TO BE SUPPLIED ND/OR VERIFIED BY TENANT'S FURNITURE VENDOR POWER & CONNUNICATIONS LEGEND Wall Mounted Duplex Outlet Wall Mounted Duplex Outlet with Ground Fault Interrupter 11 44" A.F.F. Wall Mounted 4 -Plex Outlet Wall Mounted Combination 0010/ Telephone outlet Wall Mounted Telephone Outlet Well Mounted Data Outlet Wall Mounted Ethemet Outlet Power Pole Floor Convenience Outlet Existing Outlet CT -1 Umo 0 �C1 L , 'el NBBJ 111 South Jackson Street Seattle. Washington 98104 12061 223 -5555 Fax (206) 621 -2300 LOWE ENTERPRISES NORTHWEST, INC. STANDARD REGISTER Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 Qi 10 -13-97 DP ELECTRICAL ROOM ADD'N 1 10-01-97 DP BRUIT ST Writer Dale By Dewptim of RaWora Suet Die POWER Ilk COMMUNICATION PLAN Sale I/O = t' -0 D Dote 10 -01 -97 Wet Amber TA -4 Drown 801 Cledted BP Awooed By lob Nnber 90951.09 CrTV OF OCT 1 k 1997 188017 OBNTEB D001 » 5000 3E BS 110041141J1E FR.AMS 8815 E43S 1ETAl5 & FW9H S;'8' !OW STOP W/ FOAN TAPE 8ESTAEN STOP A GLASS EA SEE. ATTACH W/ CON 11N@T NAAS (/11��3Py�EyR.E0 CLASS REUIE SCPEO - %' ULE) OMR RAIOIAKD DOOR STOP. ATTACH W/ C98L FIN91 NAL& FRL HOLES FM91 TO MATCH 0201NG ' j1 DOOR /RELITE JAMB SCALE: HALF SIZE O RECITE JAMB SCALE: HALF SIZE N: \40951_100 \101!"11 1111 STING FLOOR DECK YA 1 1/2" 3 3/4" O DOOR HEAD SCALE: HALF SIZE 25 GA SR STUDS• Y - 0 OC F.R. EOM 5/8' OR EA SIDE ACOUSTICAL CLUNG 111E ACOUSTICAL CEILING GRID FOR PA011TBN 11PE AND HEIGHT SEE CONSTRHCRDN PLAN & REFERENCE DETAIL 1/1A -8 OR 2/1A -8 SHIM AS REQUIRED 65. DOOR FRAME ATTACH 10 BLOCKING W/ COUNTERSUNK FASTENERS. FILL HOES FINISH PER SCHEDULE BS. 11110 CASING - MATCH 1057. CONDITIONS FOR REVEAL, FINISH, AND DETAILS DOOR PER SCHEDULE NOWT STOP. ATTACH W/ COUNTERSINK FN191 N9LS FILL HOLES FINISH TO MATCH EXISTING FINISHES ,10951 1xf'I -0335 1.08001 112 1 SNOS RELITE SILL SCALE: 3' = 1' -0' 4 3/r STUNG gnome ODOR ANN FRAME (30-8NIE"IE WED AE 1 -NIKIR MUM TYPICAL DOOR JAMB VINYL COMP. TILE /CARPET TRANSITION SCALE: 3' = Y -O' ?.'•:-- '„= \7 I' {T.', SCALE: FULL SIZE t \.sue: _€0j.;;L;{5T_x1T OBF,E 5EP 8113111-03386 BLOOM sir es BON SIDE MEM STEMS 0.G 8/r 140E MASS 111111 9Am1G TASIET ALL ABOUND BOTH SCE5 1/2' X 3/4' (UB) i&TN. ANTE STOP ML AROUND BOTH SONS - COVER VP W00) 191 SAP AS SHOO 1/8' X 1/8' REVEAL (TIP.) 14011-COO IIODD 9LOMG 5/8' TINE -X GIB EACH SIDE OF 2 1/8' IETAL SPAS • 24' 0.G 8000 BASE REPENT BASE CARPET (AS SCE1 110) 11\1090120\0P. 1/4' WE GLASS x111 C APP GASKET All AROUND 8018 IFS 1/2' X 3/4 BM METAL ANGLE STOP NI. AR980 BOTH STIES - C0900 NTH 11000 1141 PCP AS SHOTS 200081E RA1E0 DOOR LEAF 45 -11110IE RATED 20 ITN. D00R AND EEU1E FUME ASSEMBLY - U.L US1ED AND APPROVED AT 1-HOUR PAR1OIN5 1/8'0 1/8' REVEAL (T1.) O RELITE @ DOOR JAMB IN 1 -HOUR WALL SCALE: 3 = 1' -0" I0471451 , :., FASTEN RUNNERS TO PE8METFR WALL ANGLE AT (2) ADJACENT SIDES VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRE NOTES: NOTE N0. 1 2' MW( TIP CROSS 'Y MAN RUNNER 1. LATERAL BRACING CLUSTER (4) 12 GA CAW SOFT- ANNEAIFO (10 STEEL RRE5 SECURED TO FINN RUNNER 'M111IN 2' OF CROSS T AND SPLAYED 90 DEGREES PROM EACH OTHER AT 45 DEGREES MAX ABOVE HORIZONTAL OUSTERS PLACED 1X -0' 0.1. X U' -0' 0.C. AND 4' -0' MAX FROM EACH WALL MRCS 5NOUID BE TAUT 1111OUT CAUSING CEILING TO UFT. 2 SUSPENSION NRE: 12 GA GALV. SOT- ANNEALED MILD STEEL WIRE ENCASED IN 1/2' DIAN. 100011T (FOR UPUFT RESTRAINT): SECURE FIRE 10 MAIN RUNNER WITHIN 2' OF CROSS T. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES 10 OCCUR AT 4' -0' 0.C. MAX. EACH WAY. NOR NO RUNNER ENDS AT OPPOSITE WALLS TO FLOAT FREE CR PERIMETER ANGLE PARTITION TO MULLION SCALE: 3" = V-0" NNW WP8611570 THE (w7) 0411. R®I108 SDP ( DI192rt- C1A OM EOM) MOP 10 MATCH CA800 8900 CCNC E9E 918 1WICM. 25 GA MIL STUD PMIMS (ATTACH GIB TO TOM STUD TRY) 1' 9P ,WRR EDGE OF MEWOR SILL TEOW PAP/ 25 GA MR SBA /MST F0411 TAPE 010 NOT ATTACH SR 9P 90(1) CASING BEAD BACKER ROD & COMMUTE mutt (111. EA SCE) (STEWS WOW STE11 O g PARTITION TO WINDOW CENTER DIVIDER SCALE: 3" = 1' 0' R \!3? pILNX? P:0 MCAT 25 GA ME STUD PAIl10101 (ATTACH GM 10 PB0A8D STA 011) SLP ,0 EDGE OF111011 R9L BFLO• 25 G 110. SOD IIMNI FOAM TAPE (00 1131 ATTACH Sle 9P PPM =MUM CAS ET, SELF STEW EACH SIDE SUMP SEALANT EACH 91E EDIT AUM TO=P -SYS BY 9AL/COE +14 -O .R\ STAIN GRADE MOOD CAP STAIN CRATE 1811 01088 F.T. ND. BLOCKING . ATTACH TO TOP CAP FILL FASTENER AND SAND SMOOTH - PREPARE FOR WALL COVENI80 0081100 I5 RUNNER 5/8' GYP. BD. BOTH SIDES OVER 2 1/2' METAL STUDS RE99ENT BASE AT INIEMOR OF STATION END WALL C0NDI110N 0 SEISMIC BRACING @ CEILING GRID @ ACT 0 LOW PARTITION TOP CAP 12 1/2 STUDS) NO SCALE 4 -314 SCALE: Not to Scole K:149151_05 \0I A . PRE° ACT LNE O' -GEL GRID METH EIRE 1111 111101 SPACER ABOVE 0 BELOW SEW AT PANT OF CONNECTS( 800 ) (NN SEW TROUGH) 2A /4' ACDI51M.N 84115 AT 3 STRB PNIUIITE 04? 88 SEE PLAN FOR DEPTH WORK SURFACE SCALE: 3/4" = 1' -0" EXIST. SIRUC FLOOR — PLASTIC LAMINATE ON 3/4' M.D.F. COUNTER & CENTER SUPPORT. 410TE 1. FATE ALL GAPS IV PENETRATIONS 8(114 FI01APE/TIRESPFING MATERNAL 2 CUT DE TO FIT WATT KIN WALL RUNS PERPENDICULAR TO DECK STRUCTURE_ CONFIGURATION. UNDERSIDE OF STRUCTURE CON11N0005 CAULKING AT 1 -HOUR/ ACOUSTICAL PARTITIONS PR0W0E 2 3/4' SOUND ATTENUATION BAT15 FOR FULL EXTENT OF STUD CANNY MERE FULL- HEIGHT ACOIS1ICA1 PAR111040 ARE INDICATED ON PLAN MASHED ACT CDONG 2 1/2' K 20 GA. METAL STUDS AT Y -0' 0.0 (FOR SLAB-TO-SLAB STUDS) ONE LAYER LAMTAR G1PSU11 5 /6' GYPROC 0(4019ARD OR E0. EACH SIDE OF SRDS 1 1/4' 116E -5 DRYWALL SCREWS 0 B' 0.1. AROUND PERIMETER, 12 O.C, FIELD GYPSUM ASSN FILE NAP 1076 U.L DESIGN NO. 468 COST. 2 1/2' X 25 GA. STEEL RUNNER ANCHORED TO FLOOR 0 2' -0' 0.0. WITH COT. I/O' X 1' FOAM TAPE. WALL BASE AS SCHEDULED FINISH FLOOR AS SCHEDULED 0001180 CONCRETE FLOOR SLAB 0 TYP. FULL HEIGHT DEMISING PARTITION SCALE: 3 = 1' -0' K: \4 E0S\DR. \OET.FIEIP EXIST. 5TRUC FLOOR ATTACH CROSS BRACING TO FLO30 DECK W/ RAMSET FASTENERS, TYP. RESTORE ALL DAMAGED FIRE- PROOFING TO ORIG. FIRE RATING CROSS BRACING AT 7 -9' 0.C: 2 1/2' a 25 CA. STEEL SUITS - ATTACH W1 (3) 86 SIT MR SCREWS ATTACH CROSS BRACING DR SPACER TO RUNNER WAS 5NT MR 0018 5/8' 088 EACH SIDE 25 GA METH 01000 CONTINUOUS 011 1RA0( ANCHORED TO FLOOR • 2' -0' 0.1. BASE PER FINISH SCHEDULE FINISH FLOOR PER 181131 SCHEDULE EXISTING CONCRETE FLOOR SLAB (1S INTERIOR PARTITION (W /BRACING) TO CEILING SCALE: 3" = 1' -0" (AT UNSUPPORTED WALLS K' 4.. c. \_TI \DEL_N' GREATER THAN 7' -9' LONG) NBBJ 111 South Jackson Street Seattle. Washington 98104 (206) 223 -.3555 Fax (206) 621 -2300 &11e 1/8' = 1' -0' Nee 10 -0 -47 AEpo!> d By Sheet !irk( LOWE ENTERPRISES NORTHWEST, INC. STANDARD REGISTER Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 1 10 -01 -97 O PEdIT Reber Dote By 090404 Seen TWo DETAILS Gew 0NP Clacked EP TA-5 lob NHD, 40951.09 CRY OF U OCT 141997 PERMIT CENTER