Loading...
HomeMy WebLinkAboutPermit D97-0344 - BOEING #9-101.2 - ROOF BEAMCity of f Tukwila t_ Water: 125 Sewer: VAL VUE Wetlands: Slopes: Y Permit Center Authorized Signature: Signature: DEVELOPMENT PERMIT Print Name: (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 102304 -9069 Permit No: D97 -0344 Address: 3417 S 120 PL Status: ISSUED Suite No: Issued: 11/12/1997 Location: Expires: 05/11/1998 Category: AMFG Type: DEVPERM Zoning: MIC /L Const Type: V -1HR Occupancy: WAREHOUSE Gas /Elec.: UBC: 1994 Units: 000 Fire Protection: SPRINKLERED Setbacks: North: .0 South: .0 East: .0 West: .0 Contractor License No: BOEINC*294ML OCCUPANT BOEING #9 -101.2 PO BOX 370.7 M/S 1F -09, SEATTLE WA OWNER THE BOEING COMPANY PO BOX 3707 M/S 1F -09, SEATTLE WA CONTACT GARY TALLER Phone: 206 -544 -2975 P.O. BOX 3707 M/S 46 -87, SEATTLE, WA 98124 CONTRACTOR BOEING COMPANY P.O. BOX 3707, M/S IF -09, SEATTLE, WA 98124 **************************************************** * * ** * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: REPAIR ONE ROOF BEAM. r***************************************************** * * * * * * * * * * * * * * ** ** * * * * * * * * * * ** Construction Valuation: $ 5,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng..Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop. Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time:. Sanitary Side Sewer: N No:. Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N r********************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 169.09 r*********** * * * * * * * * * * * * * * * * * * * ** * * * * * * * * *, * * * * * ** * **, * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date://-1,— I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I:am .uthorized to sign for and obtain this development permit. Date :_24:=12 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Addr ens : 17 5 120;" PU e rmit Na D97 : 0344 Sui • i enaty t 5 -tatus ISSUED TUp;e DE'UPERM App l "i ed 10/27/1 P 6 "# 1` : Issued 1`1/12/1X97`. ** *,yak' - k ,k `k' * �k * *k k k: kkk k'* * *kk * * le4c0ik* : *'. ** * *•k * * *:k * ** *' *k ** *'.4k4 * * kk *kk'A*. ** *fib... • Permit Condit rvcha will ` be ma de .to the :plan: un p less ap , the Architect ors Eri ir�eer and the Tukr�ila.. Div "ision 2 Al: permits: i'ri .d.t r`ead�rd ;�`ar�d a pray < din ed p1 ans shall va die a i 1 ski 1 e: at/, the i t=e p "r i or 'to the �trt an.y can , struvl-lon These documents ar`e, to ,be mainta ir7ed r and ava f able until fin 1 ihspect , +n appr ova,l 7s grunted`` constr irc ,u'n' to ; b 'ban s in' contnrmancre with a ed ans and r .egei i re eats of th Un.i -f at rn Bar i l d,ihri iti `Un ifornr'M e chanical Lo d e (1994,, >�di'tth and Wee hiriq.tori '3tate Energy „Code; (1994 Editron)' Valydi y;:tof'Pe .6xThe issuan r appr�o •i plans ,, peg.if ibatio't�s arid; edmputat:i,ons ha 1.1 s trued to`. be e�}mS t ,tor.' 'ar;;, fah - ova l of , .a n t's viol t ior" of : ar of he 'prov s i ons of the . 1,opd e ';`ah;' ot � cea of tho fur isdjc:tion No perm t gir.e' hority ;to u- c�lat`e yr • ancel the provisions c.o0eide ha l 3 be •.va l r dry i fM t Elec�k fi per shall be°abta.ined ,`through the Washirgton' t t'e' 0�1,v i �� on .of Labor nd Indu e; all e l ei. tx i cal f wi l l b f.ti� e e cted :`b t hat - a enc v'''C24.8 -6630 Project Name/Tenant: ` I30E T NG BLDG . v •l - Q 1 Value of Construction: IMO Site Address: 3 � Cit State/Zip: �1 ( 7 j� �L Tax Parcel Numer: /030i-1- 9069 Property Owner: THE ROE T NG COMPANY Phone: • Street Address: BOX 3707 M/S 46 - SEATTLE VAe/i %1 2 ! fax tf: Contact Person: GARY TALLER/ P e: h�i - 544 - 2975/ Street Address: City State/Zip: P.O. ROX 3707 MIS 46 -87 SEATTLE, WA 98124 Fax #: 2 06 - 544 - 2854 Contractor: f7�. .\rn Phone: Street Address: City State /Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: c - � � 5 Phone: Street Address: City State /Zip: Fax #: Description of work to be done: }� t ILC iM,t r O hC i2-c.)0+ e a ti-, Existing use: ❑ Retail ❑ Restaurant ❑ Church 171,Manufacturing ❑ School /College /University ❑ Multi family ❑ Warehouse ❑Hospital ❑ Motel/Hotel ❑ Office ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Church rp Manufacturing ❑ School/College /University ❑ Multi - family ❑ Warehouse ❑Hospital ❑ MotelHotel ❑ Office ❑ Other Will there be a change of use? ❑ yes ❑ no If yes, extent of change: (Attach additional sheet 11 necessary) Will there be rack storage? ❑ yes 71 no Existing fire protection features: sprinklers ❑ automatic fire alarm El none ❑ other (specify) / ®, Building Square Feet: 'V 1 (ODD existing ( Area of Construction: (sq. ft.) ,2,6 Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 141 no Attach listof materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Commercial / Multi - Family Tenant Improvement / Alteration Permit Application ❑ Channellzation /Striping ❑ Land Altering 0 Cut ❑ Sanitary Side Sewer #: CITY OL . TUKWILA Perml Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 JOB N Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. ' AP PLICANT. REQUEST FO R PUBLIC;Wo KS#SITI:iCiVIt;)PL'A,'�1►REVI of TH (Addltlonelre'v/ews' tis'determ /ned?�y;tii'e Pu Works Departm`e Y ' ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent 11 SIze(s): ❑ Water Meter Temp # Size(s): ❑ Miscollaneous CTPF.RMiT.nQC 7/9/96 ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Est, quantity: Date application accepted: Date app11Fallon expires: )``1� 1 - q gal Schedule Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Application taken by: (initials) BUILD/NG OWNS OR AUT ORIZ NT: Signature: [ /lll Date: O I c: 7 `7 11 / Print name: R GARY ALLE Phone :2. — 44 -2 5 06 5 975 F ":206-544-2854 Address p.0. BOX 3707 M/S 46 -87 City /State /Zip SEATTLE, WA 98124 ALL COMMERCIAL /MULTI -FAMI ENANT IMPROVEMENT /ALTER4(ON PERMIT APPLICATIONS MUST ArSUBMITTED WITH THE FOLLOIING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas • 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ El Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as Identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health Is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit Is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. C7'I'i.:IZM17'.DOC 7/9/96 it * * � � * * * * * ?t 4 * 4 It 4 * 1ti, 4 k.t * *..* * -A •k * * s h0.4- �t * * * zl * fi a' i1 * A i,. A.1,. CITY Q.( •TUKWILA.. WA' ... //V TRANSMIT *14 .4 -AI* * ** ***** it . *, •k *A*•h*A %k*- a *** * * * *n *:+c* TRANSMIT -Nulabpr. ;I297O0667:'.Ainaunt 1b0 09.10/?7/97.14:02 a■nerlt 'Meths d CA6 Natat i ari . GARY TAL.LER I.ri i t: WFlB Per •n it .Na 097-0,344 ' • Type: QEVPEE M DEUELOPt ENT .PERMIT' Parcel' •.Uox 1023.04! -0069 Site Address: 3417 9 120 PL. 'k.* + * II ate *•h 1:* * *a` * *hA.# ;1kir* *A *k'*/ *?. *i1 *. *A *1 : *k * * ** * iv i. *lc * *st *. Ac Code Description Amount 000/322.100:, ,': BUILDING :-•. NOMREa 99.75 000/345).830 PLAN CHHI:C1( - NQN12E5 b4.84 000/386.904 TAIL BUILDING SURCHARGE 4.50 Total Fees« 169..09 Tetal' F3L:L Pmts.. 169.09 Balance: • .00 "2741 1 0/27 9711 TOT .,i69. 0.9 i INSPECTION NO CITY' OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: .J a t. it \cl .Addrltl 7 Special instructions: • S I. ..)►a) Type of insgecti n:,. 1'c Date called: -98. F' Date wanted: Requester: },e4 Phone l ! 1 � • -) ,e 1 Approved per applicable codes. Inspector: 7 INSPECTION RECORD Retain a copyy with pe it Date: bc97 -( t(LI PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: -< 1 I CITY OF..TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Special instructions: Type of inspecti • n: Date called: Project: �►C� 21.01 Address: 3(11'7 . a.m. p.m. Date wanted: Requester: It Phone No COMMENTS: A-ee it-c) . itsuiFtfitxJ Date: Approved per applicable codes. INSPECTION RECOan Retain a copy with (206) 431 -3670 Corrections required prior to approval. 74(47 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Cali to schedule reinspection. Receipt No.: Date: structural calculations roof repair boeing defense and space group thomas c wylie • • ¢x /¢ Poe oil REPo/2. REvI$/o,/ 1 pROACT Z / -o / /Roof R,P,r /iL c u c. e- ' r'at.) O.EOCED Or . EX /Smi6 . s /.1- • Rooms io/Jo2L /A)S. . &Wicf/ . f= ic,eO . ev7 - • . 0/0 "(lot . O[14ioSE . . WER E . .v A ro • 7710i4 O te/ G/dic. Posolfoit/ Joe NO. o „E / -8 -97 9T 52/ - / 0 . /3EAPIS . WEZ E . Pi-,pee. • . .4 c// ' . 7 . 0)051/4 Pcrw.ao0. D /c. . 400 . P g 5. . AoPe,,,P_ED . 7'a.. D •r v.. Gore p .CoAvdt>io /J ) . .THEREFOR • T y ” . /E. TEMP4ieAi2 SuPPb,E.T . �3 EAAlS . WiGc dE 1 5F7 . /AI . PL4c5 4.it./O . use.p. A S . P €RM MJ 7 . F,eRMI04 MEMO .S. . r . Cf1 a44Y. 2-470 F- .I- AQ 5 , Ii . TEHIPaeibey." . csuPioo4 - r .43490ss . 41000. . . f` . . . . . . /) 3 / X / 4- . V54 - LAM L VLL Mo BY 130/SE «S CANOE • rL,d' • 2(0 40 F AA b0 2 ') ' WIZ . . ' : A.aa - LANf sZ • H Y4 : /5'Y • Ro S f5o eo : 40/to9b2 Z - Vi Lez.. 1.9 E.. 23,9. .... our - . ¢ (/O f ZS, -f /D t /,S =. 5PLF i2 = 1.97 K M•z. 1I. $K» S _. 3 CI ,°� - . \C /2- Ov2>( . - 5C P5 vk sC�z1 �; ►42 = .123° .PSI FO 2 x12) I P1 e 1. - LAM Sv 3 (1,°x'1 -.1c.> /2 ( /$) q = 1M3(.11./8 = /722. <_ 115(. PSi). - ' . 321 psi Jot t.■5 (Z- 040)C 14> A. ` EA-F51 40l'- P51. 4 1,►s(tSO> = 218 psi Jou.. �/ <1'115 - (2; 3335 PSI. 4op- kit• P01l.M1 eelM/010 roxer 2i,o/ goolc 4,EPAN4 CA.C. e- .713-kr”. *CCM SY . . /tIASoA) )10 0/2- . . .4otkovs • 4- kr--Cv • . . . .... J08 MO. . . AgArit/62. . • . simpsoi/ . . .4.u/ adj we/ ra 404. ... (4) /De' Tb ,ougid • • • • V • 46 > /970 354-7 • • • • A-Miii6g4 47 datiaet7-4 PAW01. n. c.c.. Hoitiz . 2." z 1 . • • () 1 / z Y • • • • • • 134007 • • • .1r #ll_77 1 .: COX., P,9A.I / "W 8 • /Oci Pas4-11,1 • ,:73 . •Ci 3 )C9 3)(5100 z. .. ........ • ******************** V Attow t = 4-(5 4-(34-4) 2(f7 * > two_ oft" ACTIVITY NUMBER PROJECT NAME DEPARTMENT: REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F ING DIVISION El C WORKS 1'P►� 10 ��� 1 tJ L Permi-i- Cord. C.ij PLAN REVIEW / an PLAN D97 -0344 FIRE PREVENTION p STRUCTURAL R' CORRECTION DETERMINATION: BOEING BLDG. #21 -01 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE 4rJ NOT COMPLETE p COMMENTS APPROVALS OR CORRECTIONS: (ten days) DATE DATE DATE DATE 10/27/97 PLANNING DM�0�1 COORD DUE DATE 10/28/97 NOT APPLICABLE p TUES /THURS ROUTING: PLEASE ROUTE p NO FURTHER REVIEW REQUIRED p ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) 1 1 DUEDATE 11/11/97 APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) p DUE DATE APPROVED l l APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 (Certification of occupancy required. ACTIVITY NUMBER D97 -0344 PROJECT NAME BOEING BLDG. 121 -01 DEPARTMENT: BUILDING DMSION 11 FIRE PREVENTION E PLANNING DIVISION" 0 PUBLIC WORKS STRUCTURAL PERMIT COORDINATOR 1 DETERMINA N OF COMPLETENESS: (T,Th) • COMPLETE NOT COMPLETE El COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE f NO FURTHER REVIEW REQUIRED ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) • REVIEWERS INITIAL 1 1 APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED WI CONDITIONS REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED Q APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP DATE DATE DATE 0 DATE 10/27/97 DUEDATE 10/28/97 NOT APPLICABLE ❑ DUEDATE 11/11/97• NOT APPROVED (attach comments) DUEDATE NOT APPROVED (attach comments) 0 (Certification of occupancy requited. ) PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0344 PROJECT NAME BOEING BLDG. #21 -01 DATE 10/27/97 DEPARTMENT: BUILDING DIVISION FIRE PREVENTION III PLANNING DIVISION 0 PUBLIC WORKS STRUCTURAL El PERMIT COORDINATOR Q 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE COMMENTS TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.) ,REVIEWERS INITIAL c 1 APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) L-.I REVIEWERS INITIAL DATE DATE / Viv /c 7 DUE DATE 10/28/97 NOT APPLICABLE DUE DATE 11/11/97• CORRECTION DETERMINATION: DUE DATE APPROVED I 1 APPROVED W/ CONDITIONS fl NOT APPROVED (attach comments) Q REVIEWERS INITIAL C:ROUTE -F DATE (Ccrtifiadoe of occupancy :squired. ) �a` iNwa.•,]r.;.'An+lM:zums >'t -atin .t .sgemcuw!04 .w..,In el . x4Mrb'M: 100114 x ACTIVITY NUMBER 1)97 -0344 ,REVIEWERS INITIAL KS APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED El APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F ..l.Y4p sAfumk PROJECT NAME BOEING BLDG. #21 -01 DATE DATE .ri PLAN REVIEW / ROUTING SLIP DATE 10/27/97 DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION E PLANNING DIVISION III PUBLIC WORKS STRUCTURAL PERMIT COORDINATOR Q 1 4 DETERMINATION OF COMPLETENESS: (T,Th) DUEDATE 10/28/97 COMPLETE n NOT COMPLETE NOT APPLICABLE r COMMENTS TUES /THURS ROUTING: PLEASE ROUTE Ej NO FURTHER REVIEW REQUIRED ROUTED BY STAFF I I (If routed by staff, make copy to master file & enter Sierra.) DATE l z-o t DUE DATE 11/11/97• APPROVED l l APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) Q l DUE DATE NOT APPROVED (attach comments) (Certiftcadoa of occupancy required. ) c ACTIVITY NUMBER D97 -0344 PROJECT NAME BOEING BLDG. 121 -01 DEPARTMENT: BUILDING DIVISION PUBLIC WORKS REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE COMMENTS TUES /THEIRS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED lg ROUTED BY STAFF I l (If routed by staff, make copy to master file & enter Sierra.) .REVIEWERS INITIAL DATE 1 APPROVALS OR CORRECTIONS: (ten days) DUE DATE 11/11/97 APPROVED n APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) Q CORRECTION DETERMINATION: APPROVED APPROVED W/ CONDITIONS FIRE PREVENTION C PLANNING DIVISION El STRUCTURAL El PERMIT COORDINATOR a DATE DATE 10/27/97 DUE DATE 10/28/97 NOT APPLICABLE E] DATE DUE DATE NOT APPROVED (attach comments) Q (Certification of occupancy requited. I KIND. CDOMY AIRPORT OFFlCE ":rta -ntl I: CENTER (FA4) FROM SEATTLE— TACOMA AIRPORT DEVELOPMENTAL CENTER VICINITY MAP FROM DOWNTOWN SEATTLE j EXIT 158'. - ---, 9Y APPROVED ,900 157 - PROJECT SITE 900 N0.'' SCALE BLDG. 21 -01 ADDRESS: 3417 SO. 120TH PLACE TU KWI LLA, WA. ( EAST MARGINAL WAY CORPORATE PARK) AREA MAP EAST', M■RGIINAL WAY CORPORATE PARK BC E2M e FACILITIES , DEPARTMENT , ' BOEING DEVELOPMENTAL CENTER 3417 S. 120TH PLACE TUKWILA, WASHINGTON 98108 CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1 VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK! 2. NOTIFY ,FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE I DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4.'' RETURN THIS SAME SET TO GARY TALLER AT BUILDING 9 -51.2 COLUMN N /1,', AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX THESE DRAWINGS CONFORM TO THE 1994 'U.B.C., U.F.C., U.P.C. , AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10—A. BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT 1 _ 1 ACKAGE: El 1. TENANT IMPROVEMENT ((STRUCTURAL): ❑ 5 SETS OF 'ARCHITECTURAL DRAWINGS ® 5 SETS OF, STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ® 5 SETS OF ENGINEERING 'CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 2. TENANT IMPROVEMENT (NON—STRUCTURAL): ❑ 4 SETS' OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS', ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS CT 3. MECHANICAL, 4 COMPLETE SETS: • 4'. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: REPAIR ONE ROOF BEAM AUBURN 1 WA. 98002 ❑ EVERETT WA. 98201 LI KENT, IWA. 98031 ❑t'PORTLAND, OR. 97220 ' [TRENTON, WA.1 98055 SEATTLE WA. 98124 NOTES 1ACCEPTABIUTY TNIS DESIGN AND /OR 'SPECINCAIION IS APPROVED SHEET N0. DRAWN aY EDDIE 1 DUARTE G ECKED' J. BURKS ENCR. J. BURKS CHECKED 21 -01 —X LAND USE CODE CODE REFERENCES OCCUPANCY GROUP CONSTRUCTION !(PE LOCATION ON PROPERTY FLOOR AREA (ACTUAL) BUILDING HEIGHT. STORIES: OCCUPANT LOAD: FIRE PROTECTIONS SEISMIC ZONE ZONE PARKING PROVIDED PARKING REQUIRED DAIS 09.13.95' DRAWIN:0 N0. Su OLE ARCHITECTURAL MASTER DRAWING INDEX 1994 U B.C., U.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND ' COMPLIANCE WITH CITY OF TUKWILA ZONING B AND F -1, NO CHANGE IN OCCUPANCY V-1 FIR SPRINKLER SEPARATION 90 FEET (3— SIDES) BUILDING FOOTPRINT (98,000 SF) 26' -5 1/2" ' FLOOR TO PLATE 1 NO CHANGE FULLY AUTOMATIC, WET PIPE THROUGHOUT 3 3 Y ,J 739. FILE COPY 725 (I llriderstand that the Plan Check aper 1 arP t ��actlo errors and omisSlons and zp c � ^t t !aPS does not Guth OrRe:the vt71a'ikJ n•! ��T+Y \ ?!�j� ;onntLd code ..or ordinance ReCeIpt nt con- t 3,,or`s copy of approved piay ackncwtedged. 5 �1� R ECEIV ED, L j F31` CITY OFITUKW, l i Date ' UI / o, O 2 7199 CENT 7 1 r oO SHEET TITLE Perm, DG. NO. ". REVISION N0. X XX.XX.XX OF HH \J ' PPPU lE 2B UST RENSION IIS P NSEE 81 SEPACL GROUR SYM A IJ 034 REVISION BY ADD SUPPORT BEAMS EXIST GLB 6 3/406 RER APPROVED 10 -15 -97 0'T'_ SYM REVISION EXIST GLB 6 3/4x33 ROOF FRAMING PLAN SCALE: 1/8" = 1' -0" N APPROVED F) 4x14 PURLIN DF #1 ROUGH DENSE (EXIST.) BAR 2x1 /4xJ WITH 1/2'0 MB J TO LVL & P1000 TYP. EA. END EA, P1000 P1000 T 9 UNISTRUT' (5) AT 4` -0 0.C. WITH 1/2�x 0' -6" LAG BOLT TO '4x14 ACCEPTABILITY THIS DESIGN. AND /OR SPECIFICATION IS APPROVED APPROVED BY EXIST 519 6 3/4x30 SYMM. SECTION SCALE 1".1'-0" 8164 —1/2" PLYWOOD CDX -5 PLY (EXIST.) 2x4 ® 24" 0.C. D.F. #2 (EXIST.) H5 TIE AT EA. 2x4 ''''' 1/2 "x117/8" LVL EA. SIDE— HU412 W1 (22) 16d COMMON 1,, TO GIB EA. END [WITH (8) 1/4"0 x2' 1/4" H I L TI K WI K BOLT II @ 2 "CC TO 5 1/2" PC CONC. WALL PANEL ROOF FRAMING PLAN BUILDING 21 -01 STRUCTURAL MASTER COL. D— G.5/5 —B RECEIVED CITY OF. TUKWILA OCT 2 7 1997 PERMIT CENTER LEGEND: GENERAL NOTES: 1. CONDUIT SUPPORT BEAMS DESIGNED FOR 32 # /LF. CONSTRUCTION NOTES: REPAIR DAMAGED ROOF BEAM PER SECT A —S1 CORP, PARK . ASBESTOS NO11FICA11ON: A good faith survey of the building has been conducted and no asbestos containing material was discovered within this building. 0 j O 5161 % 164 S162 S165 S160 S163 SHEET JOB N0. DWG NO KEY PLAN CURRENT REVISION SYMBOL S164 21 -01 -5164 DATE COMP NO. ( +1 1/4 DO ( +1 1/2 CO ") T 1 1 3 (+1") DO I T 1 DO -- EXIST kx14 DFiti DENSE r @ 8—O " O.C., YP. I 1 UO DO I I I 1 ,i , 5164 SYM A IJ 034 REVISION BY ADD SUPPORT BEAMS EXIST GLB 6 3/406 RER APPROVED 10 -15 -97 0'T'_ SYM REVISION EXIST GLB 6 3/4x33 ROOF FRAMING PLAN SCALE: 1/8" = 1' -0" N APPROVED F) 4x14 PURLIN DF #1 ROUGH DENSE (EXIST.) BAR 2x1 /4xJ WITH 1/2'0 MB J TO LVL & P1000 TYP. EA. END EA, P1000 P1000 T 9 UNISTRUT' (5) AT 4` -0 0.C. WITH 1/2�x 0' -6" LAG BOLT TO '4x14 ACCEPTABILITY THIS DESIGN. AND /OR SPECIFICATION IS APPROVED APPROVED BY EXIST 519 6 3/4x30 SYMM. SECTION SCALE 1".1'-0" 8164 —1/2" PLYWOOD CDX -5 PLY (EXIST.) 2x4 ® 24" 0.C. D.F. #2 (EXIST.) H5 TIE AT EA. 2x4 ''''' 1/2 "x117/8" LVL EA. SIDE— HU412 W1 (22) 16d COMMON 1,, TO GIB EA. END [WITH (8) 1/4"0 x2' 1/4" H I L TI K WI K BOLT II @ 2 "CC TO 5 1/2" PC CONC. WALL PANEL ROOF FRAMING PLAN BUILDING 21 -01 STRUCTURAL MASTER COL. D— G.5/5 —B RECEIVED CITY OF. TUKWILA OCT 2 7 1997 PERMIT CENTER LEGEND: GENERAL NOTES: 1. CONDUIT SUPPORT BEAMS DESIGNED FOR 32 # /LF. CONSTRUCTION NOTES: REPAIR DAMAGED ROOF BEAM PER SECT A —S1 CORP, PARK . ASBESTOS NO11FICA11ON: A good faith survey of the building has been conducted and no asbestos containing material was discovered within this building. 0 j O 5161 % 164 S162 S165 S160 S163 SHEET JOB N0. DWG NO KEY PLAN CURRENT REVISION SYMBOL S164 21 -01 -5164 DATE COMP NO.