HomeMy WebLinkAboutPermit D97-0344 - BOEING #9-101.2 - ROOF BEAMCity of f Tukwila t_
Water: 125 Sewer: VAL VUE
Wetlands: Slopes: Y
Permit Center Authorized Signature:
Signature:
DEVELOPMENT PERMIT
Print Name:
(206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES,
APPLICANT IS PROCEEDING AT THEIR OWN RISK.
Parcel No: 102304 -9069 Permit No: D97 -0344
Address: 3417 S 120 PL Status: ISSUED
Suite No: Issued: 11/12/1997
Location: Expires: 05/11/1998
Category: AMFG
Type: DEVPERM
Zoning: MIC /L
Const Type: V -1HR Occupancy: WAREHOUSE
Gas /Elec.: UBC: 1994
Units: 000 Fire Protection: SPRINKLERED
Setbacks: North: .0 South: .0 East: .0 West: .0
Contractor License No: BOEINC*294ML
OCCUPANT BOEING #9 -101.2
PO BOX 370.7 M/S 1F -09, SEATTLE WA
OWNER THE BOEING COMPANY
PO BOX 3707 M/S 1F -09, SEATTLE WA
CONTACT GARY TALLER Phone: 206 -544 -2975
P.O. BOX 3707 M/S 46 -87, SEATTLE, WA 98124
CONTRACTOR BOEING COMPANY
P.O. BOX 3707, M/S IF -09, SEATTLE, WA 98124
**************************************************** * * ** * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Description:
REPAIR ONE ROOF BEAM.
r***************************************************** * * * * * * * * * * * * * * ** ** * * * * * * * * * * **
Construction Valuation: $ 5,000.00
PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng..Appr:
Curb Cut /Access /Sidewalk /CSS: N
Fire Loop. Hydrant: N No: Size(in): .00
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Cut: Fill
Landscape Irrigation: N
Moving Oversized Load: N Start Time: End Time:.
Sanitary Side Sewer: N No:.
Sewer Main Extension: N Private: N Public: N
Storm Drainage: N
Street Use: N
Water Main Extension: N Private: N Public: N
r********************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOTAL DEVELOPMENT PERMIT FEES: $ 169.09
r*********** * * * * * * * * * * * * * * * * * * * ** * * * * * * * * *, * * * * * ** * **, * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Date://-1,—
I hereby certify that I have read and examined this permit and know the same
to be true and correct. All provisions of law and ordinances governing this
work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or
cancel the provision of any other state or local laws regulating construction
or the performance of work. I:am .uthorized to sign for and obtain this
development permit.
Date :_24:=12
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or abandoned
for a period of 180 days from the last inspection.
Addr ens : 17 5 120;" PU e rmit Na D97 : 0344
Sui •
i enaty t 5 -tatus ISSUED
TUp;e DE'UPERM App l "i ed 10/27/1
P 6 "# 1` : Issued 1`1/12/1X97`.
** *,yak' - k ,k `k'
* �k
* *k k k: kkk
k'* * *kk * * le4c0ik* : *'. ** * *•k * * *:k * ** *' *k ** *'.4k4 * * kk *kk'A*. ** *fib...
• Permit Condit
rvcha will ` be ma de .to the :plan: un p
less ap , the
Architect ors Eri ir�eer and the Tukr�ila.. Div "ision
2 Al: permits: i'ri .d.t r`ead�rd ;�`ar�d a pray < din ed p1 ans shall
va die
a i 1 ski 1 e: at/, the i t=e p "r i or 'to the �trt an.y can ,
struvl-lon These documents ar`e, to ,be mainta ir7ed r and ava
f able until fin 1 ihspect , +n appr ova,l 7s grunted``
constr irc ,u'n' to ; b 'ban s in' contnrmancre with a ed
ans and r .egei i re eats of th Un.i -f at rn Bar i l d,ihri
iti `Un ifornr'M e chanical Lo d e (1994,, >�di'tth
and
Wee hiriq.tori '3tate Energy „Code; (1994 Editron)'
Valydi y;:tof'Pe .6xThe issuan r appr�o •i
plans ,, peg.if ibatio't�s arid; edmputat:i,ons ha 1.1
s trued to`. be e�}mS t ,tor.' 'ar;;, fah - ova l of , .a n t's viol t ior"
of : ar of he 'prov s i ons of the . 1,opd e ';`ah;'
ot � cea of tho fur isdjc:tion No perm t
gir.e' hority ;to u- c�lat`e yr • ancel the provisions
c.o0eide ha l 3 be •.va l r dry i fM t
Elec�k fi per shall be°abta.ined ,`through the Washirgton'
t t'e' 0�1,v i �� on .of Labor nd Indu e; all e l ei. tx i cal f
wi l l b f.ti�
e e cted :`b t hat - a enc v'''C24.8 -6630
Project Name/Tenant: `
I30E T NG BLDG . v •l - Q 1
Value of Construction:
IMO
Site Address: 3 � Cit State/Zip:
�1 ( 7 j� �L
Tax Parcel Numer:
/030i-1- 9069
Property Owner: THE ROE T NG COMPANY
Phone: •
Street Address: BOX 3707 M/S 46 - SEATTLE VAe/i %1 2
! fax tf:
Contact Person:
GARY TALLER/
P e:
h�i - 544 - 2975/
Street Address: City State/Zip:
P.O. ROX 3707 MIS 46 -87 SEATTLE, WA 98124
Fax #:
2 06 - 544 - 2854
Contractor:
f7�. .\rn
Phone:
Street Address: City State /Zip:
Fax #:
Architect:
Phone:
Street Address: City State /Zip:
Fax #:
Engineer: c - �
� 5
Phone:
Street Address: City State /Zip:
Fax #:
Description of work to be done: }� t
ILC iM,t r O hC i2-c.)0+ e a ti-,
Existing use: ❑ Retail ❑ Restaurant
❑ Church 171,Manufacturing
❑ School /College /University
❑ Multi family ❑ Warehouse ❑Hospital
❑ Motel/Hotel ❑ Office
❑ Other
Proposed use: ❑ Retail ❑ Restaurant
❑ Church rp Manufacturing
❑ School/College /University
❑ Multi - family ❑ Warehouse ❑Hospital
❑ MotelHotel ❑ Office
❑ Other
Will there be a change of use? ❑ yes ❑ no
If yes, extent of change: (Attach additional sheet 11 necessary)
Will there be rack storage? ❑ yes 71 no
Existing fire protection features: sprinklers ❑ automatic fire alarm El none ❑ other (specify)
/ ®,
Building Square Feet: 'V 1 (ODD existing
( Area of Construction: (sq. ft.) ,2,6
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 141 no
Attach listof materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets
Commercial / Multi - Family Tenant Improvement / Alteration Permit Application
❑ Channellzation /Striping
❑ Land Altering 0 Cut
❑ Sanitary Side Sewer #:
CITY OL . TUKWILA
Perml Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670 JOB N
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mall or facsimile. '
AP PLICANT. REQUEST FO R PUBLIC;Wo KS#SITI:iCiVIt;)PL'A,'�1►REVI of TH
(Addltlonelre'v/ews' tis'determ /ned?�y;tii'e Pu Works Departm`e Y '
❑ Storm Drainage ❑ Street Use
❑ Water Meter /Exempt #: Size(s):
❑ Water Meter /Permanent 11 SIze(s):
❑ Water Meter Temp # Size(s):
❑ Miscollaneous
CTPF.RMiT.nQC 7/9/96
❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling
cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation
❑ Sewer Main Extension 0 Private 0 Public
❑ Water Main Extension 0 Private 0 Public
0 Deduct 0 Water Only
Est, quantity:
Date application accepted:
Date app11Fallon expires:
)``1� 1 - q
gal Schedule
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and
is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by
the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
Application taken by: (initials)
BUILD/NG OWNS OR AUT ORIZ NT:
Signature: [
/lll
Date: O I c: 7 `7
11 /
Print name: R
GARY ALLE
Phone :2. — 44 -2 5
06 5 975
F ":206-544-2854
Address p.0. BOX 3707
M/S 46 -87
City /State /Zip SEATTLE, WA 98124
ALL COMMERCIAL /MULTI -FAMI ENANT IMPROVEMENT /ALTER4(ON PERMIT APPLICATIONS
MUST ArSUBMITTED WITH THE FOLLOIING:
➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT,
STRUCTURAL ENGINEER OR CIVIL ENGINEER
➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ ❑ Complete Legal Description
❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Five (5) sets of working drawings, which include :
❑ ❑ Site Plan (including existing fire hydrant location(s)
1. North arrow and scale
2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas •
5. Recycle collection location and area calculations (change of use only)
6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of
use only)
9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of
those, identify by size and species which are to be removed and saved
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change
of use only)
11. Location and gross floor area of existing structure with dimensions and setback
12. Lowest finished floor elevation (if in flood control zone)
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H-
9).
❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled
❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of
any hazardous materials; dimensions of proposed tenant space.
❑ ❑ Vicinity Map showing location of site
❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of
rack. Structural calculations are required for rack storage eight feet and over.
❑ El Indicate proposed construction of tenant space or addition and walls being demolished
❑ ❑ Construction details
❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of
water supply to sprinkler vault with documentation from contractor stating supply line will meet or
exceed sprinkler system design criteria as Identified by the Fire Department.
❑ ❑ Washington State Non - Residential Energy Code Date shall be noted on the construction drawings.
❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds).
❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
land use or SEPA decisions.
❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of
Public Health Is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5)
❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no
contractor has been selected at time of application a copy of this license will be required before the
permit Is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
C7'I'i.:IZM17'.DOC 7/9/96
it * * � � * * * * * ?t 4 * 4 It 4 * 1ti, 4 k.t * *..* * -A •k * * s h0.4- �t * * * zl * fi a' i1 * A i,. A.1,.
CITY Q.( •TUKWILA.. WA' ... //V TRANSMIT
*14 .4 -AI* * ** ***** it . *, •k *A*•h*A %k*- a *** * * * *n *:+c*
TRANSMIT -Nulabpr. ;I297O0667:'.Ainaunt 1b0 09.10/?7/97.14:02
a■nerlt 'Meths d CA6 Natat i ari . GARY TAL.LER I.ri i t: WFlB
Per •n it .Na 097-0,344 ' • Type: QEVPEE M DEUELOPt ENT .PERMIT'
Parcel' •.Uox 1023.04! -0069
Site Address: 3417 9 120 PL.
'k.* + * II ate *•h 1:* * *a` * *hA.# ;1kir* *A *k'*/ *?. *i1 *. *A *1 : *k * * ** * iv i. *lc * *st *.
Ac Code Description Amount
000/322.100:, ,': BUILDING :-•. NOMREa 99.75
000/345).830 PLAN CHHI:C1( - NQN12E5 b4.84
000/386.904
TAIL BUILDING SURCHARGE 4.50
Total Fees« 169..09
Tetal' F3L:L Pmts.. 169.09
Balance: • .00
"2741 1 0/27 9711 TOT .,i69. 0.9
i
INSPECTION NO
CITY' OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Project: .J a
t. it \cl
.Addrltl 7
Special instructions: •
S I. ..)►a)
Type of insgecti n:,.
1'c
Date called:
-98. F'
Date wanted:
Requester:
},e4
Phone l ! 1 �
• -) ,e 1
Approved per applicable codes.
Inspector:
7
INSPECTION RECORD
Retain a copyy with pe it
Date:
bc97 -( t(LI
PERMIT NO.
(206) 431 -3670
Corrections required prior to approval.
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection.
Receipt No.:
Date:
-<
1
I
CITY OF..TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Special instructions:
Type of inspecti • n:
Date called:
Project:
�►C� 21.01
Address:
3(11'7 .
a.m.
p.m.
Date wanted:
Requester: It
Phone No
COMMENTS:
A-ee it-c) .
itsuiFtfitxJ
Date:
Approved per applicable codes.
INSPECTION RECOan
Retain a copy with
(206) 431 -3670
Corrections required prior to approval.
74(47
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100, Cali to schedule reinspection.
Receipt No.:
Date:
structural calculations roof repair
boeing defense and space group
thomas c wylie
•
•
¢x /¢ Poe oil REPo/2.
REvI$/o,/ 1
pROACT Z / -o / /Roof R,P,r /iL
c u c. e- ' r'at.)
O.EOCED Or
. EX /Smi6 . s /.1- • Rooms io/Jo2L /A)S. . &Wicf/ . f= ic,eO . ev7 - •
. 0/0 "(lot . O[14ioSE . . WER E . .v A ro • 7710i4
O te/ G/dic. Posolfoit/
Joe NO.
o „E / -8 -97 9T 52/ - / 0 .
/3EAPIS . WEZ E . Pi-,pee. • . .4 c// '
. 7 . 0)051/4 Pcrw.ao0. D /c. . 400 .
P g 5. . AoPe,,,P_ED . 7'a.. D •r v.. Gore p .CoAvdt>io /J )
. .THEREFOR • T y ” .
/E. TEMP4ieAi2 SuPPb,E.T . �3 EAAlS . WiGc dE
1 5F7 . /AI . PL4c5 4.it./O . use.p. A S . P €RM MJ 7 . F,eRMI04 MEMO .S. .
r . Cf1 a44Y. 2-470 F- .I- AQ 5 ,
Ii
. TEHIPaeibey." . csuPioo4 - r .43490ss . 41000. . .
f`
. . . . . . /) 3 / X / 4- . V54 - LAM L VLL Mo BY 130/SE «S CANOE •
rL,d' • 2(0 40 F
AA b0
2 ') ' WIZ . . ' : A.aa - LANf sZ • H Y4 : /5'Y • Ro S f5o eo : 40/to9b2
Z - Vi Lez.. 1.9 E..
23,9. .... our - . ¢ (/O f ZS, -f /D t /,S =. 5PLF
i2 = 1.97 K
M•z. 1I. $K»
S _. 3 CI ,°� - . \C /2- Ov2>( . - 5C P5
vk sC�z1
�; ►42 = .123° .PSI
FO 2 x12) I P1 e 1. - LAM
Sv 3 (1,°x'1 -.1c.> /2 ( /$)
q = 1M3(.11./8 = /722.
<_ 115(. PSi). - ' . 321 psi Jot
t.■5 (Z- 040)C 14> A. ` EA-F51 40l'-
P51. 4 1,►s(tSO> = 218 psi Jou..
�/ <1'115 - (2; 3335 PSI. 4op-
kit• P01l.M1
eelM/010
roxer 2i,o/ goolc 4,EPAN4
CA.C. e- .713-kr”. *CCM SY
. . /tIASoA) )10 0/2- . .
.4otkovs • 4- kr--Cv •
. . .
....
J08 MO.
. . AgArit/62. .
• . simpsoi/ . . .4.u/ adj we/ ra 404. ...
(4) /De' Tb ,ougid •
• • • V • 46 > /970 354-7 • • • •
A-Miii6g4 47 datiaet7-4 PAW01.
n. c.c.. Hoitiz . 2."
z 1
. • •
() 1 / z Y • • • • • • 134007
• • • .1r
#ll_77 1 .:
COX., P,9A.I / "W
8 •
/Oci Pas4-11,1
• ,:73 .
•Ci 3 )C9 3)(5100 z. .. ........
• ********************
V Attow t = 4-(5 4-(34-4) 2(f7 * > two_
oft"
ACTIVITY NUMBER
PROJECT NAME
DEPARTMENT:
REVIEWERS INITIAL
REVIEWERS INITIAL
REVIEWERS INITIAL
C:ROUTE -F
ING DIVISION El
C WORKS
1'P►� 10 ��� 1 tJ
L
Permi-i- Cord. C.ij
PLAN REVIEW / an
PLAN
D97 -0344
FIRE PREVENTION p
STRUCTURAL
R'
CORRECTION DETERMINATION:
BOEING BLDG. #21 -01
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE 4rJ NOT COMPLETE p
COMMENTS
APPROVALS OR CORRECTIONS: (ten days)
DATE
DATE
DATE
DATE 10/27/97
PLANNING DM�0�1
COORD
DUE DATE 10/28/97
NOT APPLICABLE p
TUES /THURS ROUTING: PLEASE ROUTE p NO FURTHER REVIEW REQUIRED p
ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.)
1
1
DUEDATE 11/11/97
APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) p
DUE DATE
APPROVED l l APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0
(Certification of occupancy required.
ACTIVITY NUMBER D97 -0344
PROJECT NAME BOEING BLDG. 121 -01
DEPARTMENT:
BUILDING DMSION 11 FIRE PREVENTION E PLANNING DIVISION" 0
PUBLIC WORKS STRUCTURAL PERMIT COORDINATOR
1
DETERMINA N OF COMPLETENESS: (T,Th)
• COMPLETE NOT COMPLETE El
COMMENTS •
TUES /THURS ROUTING: PLEASE ROUTE f NO FURTHER REVIEW REQUIRED
ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.)
• REVIEWERS INITIAL
1
1
APPROVALS OR CORRECTIONS: (ten days)
APPROVED n APPROVED WI CONDITIONS
REVIEWERS INITIAL
CORRECTION DETERMINATION:
APPROVED Q APPROVED W/ CONDITIONS
REVIEWERS INITIAL
C:ROUTE -F
PLAN REVIEW / ROUTING SLIP
DATE
DATE
DATE
0
DATE 10/27/97
DUEDATE 10/28/97
NOT APPLICABLE ❑
DUEDATE 11/11/97•
NOT APPROVED (attach comments)
DUEDATE
NOT APPROVED (attach comments) 0
(Certification of occupancy requited. )
PLAN REVIEW / ROUTING SLIP
ACTIVITY NUMBER D97 -0344
PROJECT NAME BOEING BLDG. #21 -01
DATE 10/27/97
DEPARTMENT:
BUILDING DIVISION FIRE PREVENTION III PLANNING DIVISION 0
PUBLIC WORKS STRUCTURAL El PERMIT COORDINATOR Q
1
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE NOT COMPLETE
COMMENTS
TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED
ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.)
,REVIEWERS INITIAL
c
1
APPROVALS OR CORRECTIONS: (ten days)
APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) L-.I
REVIEWERS INITIAL
DATE
DATE
/ Viv /c 7
DUE DATE 10/28/97
NOT APPLICABLE
DUE DATE 11/11/97•
CORRECTION DETERMINATION: DUE DATE
APPROVED I 1 APPROVED W/ CONDITIONS fl NOT APPROVED (attach comments) Q
REVIEWERS INITIAL
C:ROUTE -F
DATE
(Ccrtifiadoe of occupancy :squired. )
�a` iNwa.•,]r.;.'An+lM:zums >'t -atin .t .sgemcuw!04 .w..,In el . x4Mrb'M: 100114 x
ACTIVITY NUMBER 1)97 -0344
,REVIEWERS INITIAL KS
APPROVALS OR CORRECTIONS: (ten days)
REVIEWERS INITIAL
CORRECTION DETERMINATION:
APPROVED El APPROVED W/ CONDITIONS
REVIEWERS INITIAL
C:ROUTE -F
..l.Y4p sAfumk
PROJECT NAME BOEING BLDG. #21 -01
DATE
DATE
.ri
PLAN REVIEW / ROUTING SLIP
DATE 10/27/97
DEPARTMENT:
BUILDING DIVISION El FIRE PREVENTION E PLANNING DIVISION III
PUBLIC WORKS STRUCTURAL PERMIT COORDINATOR Q
1
4
DETERMINATION OF COMPLETENESS: (T,Th) DUEDATE 10/28/97
COMPLETE n NOT COMPLETE NOT APPLICABLE r
COMMENTS
TUES /THURS ROUTING: PLEASE ROUTE Ej NO FURTHER REVIEW REQUIRED
ROUTED BY STAFF I I (If routed by staff, make copy to master file & enter Sierra.)
DATE l z-o
t
DUE DATE 11/11/97•
APPROVED l l APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) Q
l
DUE DATE
NOT APPROVED (attach comments)
(Certiftcadoa of occupancy required. )
c
ACTIVITY NUMBER D97 -0344
PROJECT NAME BOEING BLDG. 121 -01
DEPARTMENT:
BUILDING DIVISION
PUBLIC WORKS
REVIEWERS INITIAL
REVIEWERS INITIAL
C:ROUTE -F
PLAN REVIEW / ROUTING SLIP
4
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE NOT COMPLETE
COMMENTS
TUES /THEIRS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED lg
ROUTED BY STAFF I l (If routed by staff, make copy to master file & enter Sierra.)
.REVIEWERS INITIAL DATE 1
APPROVALS OR CORRECTIONS: (ten days) DUE DATE 11/11/97
APPROVED n APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) Q
CORRECTION DETERMINATION:
APPROVED APPROVED W/ CONDITIONS
FIRE PREVENTION C PLANNING DIVISION El
STRUCTURAL El PERMIT COORDINATOR a
DATE
DATE 10/27/97
DUE DATE 10/28/97
NOT APPLICABLE E]
DATE
DUE DATE
NOT APPROVED (attach comments) Q
(Certification of occupancy requited.
I KIND. CDOMY
AIRPORT OFFlCE
":rta -ntl I: CENTER (FA4)
FROM SEATTLE— TACOMA AIRPORT
DEVELOPMENTAL CENTER
VICINITY MAP
FROM DOWNTOWN SEATTLE
j
EXIT
158'. - ---,
9Y APPROVED
,900
157 -
PROJECT
SITE
900
N0.'' SCALE
BLDG. 21 -01 ADDRESS:
3417 SO. 120TH PLACE
TU KWI LLA, WA.
( EAST MARGINAL WAY
CORPORATE PARK)
AREA MAP
EAST', M■RGIINAL WAY CORPORATE PARK
BC E2M e
FACILITIES , DEPARTMENT , '
BOEING DEVELOPMENTAL CENTER
3417 S. 120TH PLACE
TUKWILA, WASHINGTON 98108
CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST
BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT
ABOVE MENTIONED SET OF DOCUMENTS.
1 VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK!
2. NOTIFY ,FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE I DESIGN REVISIONS.
3. COORDINATE WORK WITH OTHER CRAFTS.
4.'' RETURN THIS SAME SET TO GARY TALLER AT BUILDING 9 -51.2 COLUMN N /1,',
AFTER COMPLETION OF THIS CONSTRUCTION.
PROJECT CHECKLIST
CHECK
BOX
THESE DRAWINGS CONFORM TO THE 1994 'U.B.C., U.F.C., U.P.C. ,
AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES
AND COMPLIANCE WITH CITY OF TUKWILA ZONING.
❑ ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10—A.
BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION.
NUMBER OF PRINTS REQUIRED FOR PERMIT 1 _ 1 ACKAGE:
El 1. TENANT IMPROVEMENT ((STRUCTURAL):
❑ 5 SETS OF 'ARCHITECTURAL DRAWINGS
® 5 SETS OF, STRUCTURAL DRAWINGS
❑ 5 SETS OF STANDARD DETAILS
® 5 SETS OF ENGINEERING 'CALCULATIONS
❑ 5 SETS OF ENERGY CALCULATIONS
❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS
❑ 2. TENANT IMPROVEMENT (NON—STRUCTURAL):
❑ 4 SETS' OF ARCHITECTURAL DRAWINGS
❑ 4 SETS OF STANDARD DETAILS
❑ 4 SETS OF ENERGY CALCULATIONS',
❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS
CT 3. MECHANICAL, 4 COMPLETE SETS:
• 4'. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS.
® BRIEF PROJECT NARRATIVE:
REPAIR ONE ROOF BEAM
AUBURN 1 WA. 98002
❑ EVERETT WA. 98201
LI KENT, IWA. 98031
❑t'PORTLAND, OR. 97220 '
[TRENTON, WA.1 98055
SEATTLE WA. 98124
NOTES
1ACCEPTABIUTY
TNIS DESIGN AND /OR
'SPECINCAIION IS APPROVED
SHEET
N0.
DRAWN aY
EDDIE 1 DUARTE
G ECKED'
J. BURKS
ENCR.
J. BURKS
CHECKED
21 -01 —X
LAND USE CODE
CODE REFERENCES
OCCUPANCY GROUP
CONSTRUCTION !(PE
LOCATION ON PROPERTY
FLOOR AREA (ACTUAL)
BUILDING HEIGHT.
STORIES:
OCCUPANT LOAD:
FIRE PROTECTIONS
SEISMIC ZONE
ZONE
PARKING PROVIDED
PARKING REQUIRED
DAIS
09.13.95'
DRAWIN:0
N0.
Su OLE
ARCHITECTURAL MASTER
DRAWING INDEX
1994 U B.C., U.F.C., U.P.C., AND THE WAC 51 -20 AS
ADAPTED OR AMENDED BY LOCAL ORDINANCES AND '
COMPLIANCE WITH CITY OF TUKWILA ZONING
B AND F -1, NO CHANGE IN OCCUPANCY
V-1 FIR SPRINKLER
SEPARATION 90 FEET (3— SIDES)
BUILDING FOOTPRINT (98,000 SF)
26' -5 1/2" ' FLOOR TO PLATE
1
NO CHANGE
FULLY AUTOMATIC, WET PIPE THROUGHOUT
3
3 Y ,J
739. FILE COPY
725
(I llriderstand that the Plan Check aper 1 arP
t ��actlo errors and omisSlons and zp c � ^t
t !aPS does not Guth OrRe:the vt71a'ikJ n•! ��T+Y \ ?!�j�
;onntLd code ..or ordinance ReCeIpt nt con-
t 3,,or`s copy of approved piay ackncwtedged.
5 �1� R ECEIV ED,
L
j F31` CITY OFITUKW,
l i Date ' UI / o, O 2 7199 CENT 7 1
r oO
SHEET TITLE
Perm,
DG. NO. ".
REVISION
N0.
X XX.XX.XX
OF
HH \J
' PPPU lE
2B
UST RENSION IIS
P NSEE 81 SEPACL GROUR
SYM
A
IJ 034
REVISION BY
ADD SUPPORT BEAMS
EXIST GLB 6 3/406
RER
APPROVED
10 -15 -97
0'T'_
SYM
REVISION
EXIST GLB 6 3/4x33
ROOF FRAMING PLAN
SCALE: 1/8" = 1' -0" N
APPROVED
F)
4x14 PURLIN DF #1 ROUGH DENSE
(EXIST.)
BAR 2x1 /4xJ
WITH 1/2'0 MB J
TO LVL & P1000
TYP. EA. END
EA, P1000
P1000 T 9 UNISTRUT'
(5) AT 4` -0 0.C. WITH
1/2�x 0' -6" LAG
BOLT TO '4x14
ACCEPTABILITY
THIS DESIGN. AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
EXIST 519 6 3/4x30
SYMM.
SECTION
SCALE 1".1'-0" 8164
—1/2" PLYWOOD
CDX -5 PLY (EXIST.)
2x4 ® 24" 0.C.
D.F. #2 (EXIST.)
H5 TIE AT EA. 2x4
''''' 1/2 "x117/8" LVL EA. SIDE—
HU412 W1 (22) 16d COMMON
1,, TO GIB EA. END [WITH (8)
1/4"0 x2' 1/4" H I L TI K WI K
BOLT II @ 2 "CC TO 5 1/2" PC
CONC. WALL PANEL
ROOF FRAMING PLAN
BUILDING 21 -01
STRUCTURAL MASTER COL. D— G.5/5 —B
RECEIVED
CITY OF. TUKWILA
OCT 2 7 1997
PERMIT CENTER
LEGEND:
GENERAL NOTES:
1. CONDUIT SUPPORT BEAMS DESIGNED FOR 32 # /LF.
CONSTRUCTION NOTES:
REPAIR DAMAGED ROOF BEAM PER SECT A —S1
CORP, PARK
. ASBESTOS NO11FICA11ON:
A good faith survey of the building has been conducted
and no asbestos containing material was discovered
within this building.
0
j
O
5161
%
164
S162
S165
S160
S163
SHEET
JOB N0.
DWG NO
KEY PLAN
CURRENT REVISION
SYMBOL
S164
21 -01 -5164
DATE
COMP NO.
( +1 1/4
DO
( +1 1/2
CO
")
T
1
1
3
(+1")
DO
I
T
1
DO
-- EXIST kx14 DFiti DENSE
r @ 8—O " O.C., YP.
I
1
UO
DO
I
I
I
1
,i
,
5164
SYM
A
IJ 034
REVISION BY
ADD SUPPORT BEAMS
EXIST GLB 6 3/406
RER
APPROVED
10 -15 -97
0'T'_
SYM
REVISION
EXIST GLB 6 3/4x33
ROOF FRAMING PLAN
SCALE: 1/8" = 1' -0" N
APPROVED
F)
4x14 PURLIN DF #1 ROUGH DENSE
(EXIST.)
BAR 2x1 /4xJ
WITH 1/2'0 MB J
TO LVL & P1000
TYP. EA. END
EA, P1000
P1000 T 9 UNISTRUT'
(5) AT 4` -0 0.C. WITH
1/2�x 0' -6" LAG
BOLT TO '4x14
ACCEPTABILITY
THIS DESIGN. AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
EXIST 519 6 3/4x30
SYMM.
SECTION
SCALE 1".1'-0" 8164
—1/2" PLYWOOD
CDX -5 PLY (EXIST.)
2x4 ® 24" 0.C.
D.F. #2 (EXIST.)
H5 TIE AT EA. 2x4
''''' 1/2 "x117/8" LVL EA. SIDE—
HU412 W1 (22) 16d COMMON
1,, TO GIB EA. END [WITH (8)
1/4"0 x2' 1/4" H I L TI K WI K
BOLT II @ 2 "CC TO 5 1/2" PC
CONC. WALL PANEL
ROOF FRAMING PLAN
BUILDING 21 -01
STRUCTURAL MASTER COL. D— G.5/5 —B
RECEIVED
CITY OF. TUKWILA
OCT 2 7 1997
PERMIT CENTER
LEGEND:
GENERAL NOTES:
1. CONDUIT SUPPORT BEAMS DESIGNED FOR 32 # /LF.
CONSTRUCTION NOTES:
REPAIR DAMAGED ROOF BEAM PER SECT A —S1
CORP, PARK
. ASBESTOS NO11FICA11ON:
A good faith survey of the building has been conducted
and no asbestos containing material was discovered
within this building.
0
j
O
5161
%
164
S162
S165
S160
S163
SHEET
JOB N0.
DWG NO
KEY PLAN
CURRENT REVISION
SYMBOL
S164
21 -01 -5164
DATE
COMP NO.