Loading...
HomeMy WebLinkAboutPermit D97-0364 - TREASURE CHEST - PARTITION AND CEILING DEMOLITIONCity of Tukwila C.. Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 252304 -9078 Permit No: D97 -0364 Address: 16300 CHRISTENSEN RD Status: ISSUED Suite No: 217 Issued: 01/05/1998 Location: Expires: 07/04/1998 Category: AOFF Type: DEVPERM Zoning: TUC Const Type: Occupancy: OFFICE Gas /Elec.: UBC: 1994 Units: 001 Fire Protection: SPRINKLERS Setbacks: North: .0 South: .0 East: .0 West: .0 Water: TUKWILA Sewer: TUKWILA Wetlands: Slopes: Y Streams: Contractor License No: AO -SePdro Pti- OCCUPANT TREASURE CHEST Phone: 206 241 -5258 16300 CHRISTENSEN RD, TUKWILA WA 98188 OWNER JOHN HANCOCK MUTUAL LIFE Phone: (206)431 -8336 16040 CHRISTENSEN RD #214, TUKWILA WA 98188 CONTACT CHUCK MAHLUM Phone: 206 -241 -5258 16000 CHRISTENSEN RD., TUKWILA, WA 98188 CONTRACTOR ALL SEASON. PAINTING Phone:_ 425 -803 -9532 11032 104 AV NE, KIRKLAND WA 98033 k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: DEMOLITION PARTITION PLAN AND REFLECTED CEILING PLAN. k************************** k************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 9,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS:•.N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time Land Altering: N Cut:. Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 0 251.59 k******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *********** J* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date _k f��_ Permit Center Authorized Signature:_ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development per t. DEVELOPMENT PERMIT Date: J 5:9t Signature:__ Print Name: __ e, __4(61/1W E This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. (206) 431 -3670 Atidr 1630q CH RI' ' ST EN�EN RCS r er rn i Sul te Te.n rat', S tattis ISSUE vrpe: GE:VPERM Appi #ed" 11/2041997 arcei 1t 252304;` :9tl7il T ssue d 01/05/1 • k**4 :'k k4kk kA; k* kkk ik M1r*4*kk k*kk . k,k*kk** kk:k•kkk*•kkk : 4.k khk!rk�t ".k. er rn ii. C.on 1: No changes w #1.1:be made to the p1' n� unies a p prDyed by the • • Ar ch1tect or En'g`ineer acid rile; T kwiis •Bu 11di t.; sjan.. 2 E1 e.ctri,ca l jee m . 4. (..e �ohtairie hrou the Washitigtan " Stta`te'l7' #vision of Lahr and Indu tr, ie s'n.dry eirl :.e :l'er.tr ical work W,i'i i be. e Tcted by that. agency '(248 = 6630) ? ;: errnit ns'reftiorin, records, rrnd,a.pp land; sha'l1; able at;, i t�e job 'site p or;`to the start o °f ar #y�Ycon. t rue0on , : ,.The e�;dor.Unrent� art t a . a avai bl ^`e unt�r1 .f na i, i pectTarr `appr'aval is orga red ? } at ^ti I:0,1'1'4,1,44104; `aTt aehe+.i- to cei °l r jig gr id irtUst be, late a '11 bx ace,:d� f- ov r "e : ight;�(8) feet in': lengt Al 1 co is i on to' be dori'e' .i c.on Tormance. with . appr ;ove i plans yaitd .qui erner7t of the Un�f arm:Buil di ng'Code (199 Ede -ti n> � ,arisen d, . Unif:arm ; Meihani�al Gocie 11994 . Edit i and, awash 1 ton a;tat :: En pcie ,t 1934 Cd i t iori,) Valid' y nYof �'e �ii.i t The ~tysuan of 3 per ~m t :or e pp r ov 1 R1ans ,specif�,catian and cdm putat c'ns h al l not be cor rr`ued to • b:e e p'er m i t for o s ova I . !'of t :any v iol a`t.i o at `ah of tfle *pr.ov i 5.i ans`Lof, code 'or of `Any,,a • others orrdinance , at they ]t%r isd:1 tion �':No per nrit pr e,,0 60:11 F � g ive0 1 authorl ty toF violate a r" • rth'e pruvis#an$;of th 66dei sha11 Abe ^va11d Pro' ct Name enant: iJt�.r, 4r i e4- — 7 s c)A.E (Z' es? ( 4 a Value of Constructionl�` o111 Site Address: City tate/Zip: �lo . / 576,125 o J (55.. 27/ ii4 ( . 7J/8 ex Parcel Number: '_,27S2-3o 'i - -0 Property Owne • W / ..(■, Phone: c,21 age ,S - zsg Street Addr: •s: Existing fire protection features: Mprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) i,4 /. - ity S1te2ip8 Fax 0dG 4 y/ — 76/ Contact Person: vz.4- /�ING-viw -- Phone: aNl •- SL 5'8 Street Adess: sr& o ., to /,,� 2 /Lb 4 ity St to /Zi Yi Fax #: o?yl - 7 S7 Z... Phone: 003 •— 7r3 z- Fax #: 80 3 — ?s.3 Z ontractor: Sari Street Address: 1123 Z— ��r , • 6 j/ At* . /�l a0 ha; ?San /Zip: Y Architect: /J _ L /647 *41,1A, Phone: /7O - 670b [' Stree Address: o 4 - Slv 20�{ / !. 11. City St e/Zip: a�3 Fax #: 77 �� g 2,1 Engineer: Phone: Street Address: City State /Zip: Fax #: Description of work to be done: )i 2(,, Q.1 7 . 4'0-14 ,9z,�� i.:,, ' " /4 or p.A4 Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse( Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel 75 Office ❑ SchooVCollege /University ❑ Other Will there be a change of use? ❑ yes jg no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 21 no Existing fire protection features: Mprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 7s; 474- existing Area of Construction: (sq. it.) p Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 in the building? ❑ yes no X 11 paper indicating quantities & Material Safety Data Sheets CTPERMIT.DOC 7/9/96 CITY OFCUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL.PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined: by the P ublic Works Department) ❑ Channelization /Striping ❑ Land Altering 0 Cut cubic yds. ❑ Sanitary Side Sewer #• ❑ Storm Drainage ❑ Stree: Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zona ❑ Hauling O Fill cubic yds. ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public Cl Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Est. quantity: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. gal Schedule: Appl ation a.:n • Initials) BUILDING OW R O AUTHOR; ED AGENT: Signature: ��GG�C ei Date: /� � 3 fq7 Print name: ( ayA /��`' e Aye -vim._ Ph aw S ax #: 1 �Y / -7s /z.. Address ••, 9 eActiSTzA) J , ,. t o /a,ri� awWc7 ,vita City /Staje iotA r9 pp,98 ALL COMMERCIAL /MULTI -FA/IV TENANT IMPROVEMENT/ALTISITION PERMIT APPLICATIONS MUSiTIE SUBMITTED WITH THE FOLL ING: lA ; D A AWINPF, To BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, fi �''UdTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUB ITTED ❑ Complete Legal Description ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : ❑ EJ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9, identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18,45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Chec,clist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ lel Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of �.�( any hazardous materials; dimensions of proposed tenant space. ❑ LJ Vicinity Map showing location of site ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ Ti Indicate proposed construction of tenant space or addition and walls being demolished in gi Construction details 7i ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ 71 Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). © ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other �1 land use or SEPA decisions. IYl ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ( ❑ Cop of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu. of Certificate of Contractor ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized I&tter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE RE ID D AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 7/9/96 • .M.'n «m..a:�r . rv•• fu. wv.:..._ �. a.: va„ a; a: r .nf�n4�uVse.,.r�.,,d.r........, ... ................. r.. w..... uuAe. i«..-. ww.. rtvvMrww.M.Tnux'nn•vent+v�r.... rev. rr... vrur•. rv.. a....... n.. vaw• uvwr.. nl. wnfn. atwm ..r�rr..n+.- �Iw..rtMVanwwna�e. ACTIVITY NUMBER REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INTrIAL C:ROUTE -F P€XmI# card. a PLAN REVIEW / ROUTING SLIP D97 -0364 PROJECT NAME TREASURE SST APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: DATE DATE DATE •w.h+rm✓• DATE 11/20/97 DEPARTMENT: B 127 ING DIVISION ❑) FIRE PREVENTION PLNINBIG DIVISION ❑ W illc WORKS ❑ M ❑ emrr COORDIN2TOR in o . N) A - KIP1 ._._,,...... 4 DETERMINA ON OF COMPLETENESS: (T,Th) DUE DATE 11/25/97 • COMPLETE NOT COMPLETE ❑ NOT APPLICABLE ❑ COMMENTS TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF f1 (If routed by staff, make copy to master file & enter Sierra.) 1 1 DUEDATE 12/9/97 ' APPROVED n APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ DUE DATE APPROVED 1 APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Certification of occupancy required. ) iF1c *01i, * * 1 4 14'* ** *' *.t*-460,Ask *, *A :A t *•k::k * * k ;Ah;t *A *:r.it.k t k,k *A * G`I l Y 0F 1 UKW] L A:, 11tH • ] ( ] TRANSMIT * *k *!c *-k* * * * * *A * *:A***** k *t % *A k. A. k * 4c *Ak:AkiekAAkkkkA{r•A• * *,1.. TRAr1$M1j R9Iq.Oi B2. - "251.55 11/20/57; 1.1,128 avmer►t. Methods RIVERVIE 1. PLAZA In.it : WAD Permit:: t1.Oi 'D97:- -03 4 .Tvp'ec DEVPEI�M I)Ev PI Iu Ir . Parcel Nn 252304 ^cr078 .3i'te Addi^ess.s' 11,300 CHRI,STENSEi1• RU .. fatal 1= ee4: 251.59 251.53 T.otaal.. fL.L Pmts:. 251»a5 1341 once: • A() * A.ii; * * *.l:a'`,•;*i.kitd *i1' ..•h **°A'0•kAitA,A•. *00:1,4.01 .,k a•c 4-* it k'it. *i~i• *A**a.i * *iv AcLount Cnd,e .Descrjption.. , A00432 . 2.2100': HU1L DINS NCINRES 000/34,5.830.. PLAN GNLCI( - 1N0NRES 000/3S6..:104 STATE ,BUILDING SURCHARGE Amount 149.!5 97.34 4.50 Project. Type of inspection:' Addre$s i tom_ ciltu Date called:. 1_7_ c Special instructions: Date wanted: l _ 8—W ( a.m) P.m. Requester ,,„� U(1 /") l )L»v Phone No.: INSPECTION Ni. CITY OF TUKWILA BUILDING DIVISION '6300 Sotithcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. l ' Corrections required prior to approval. COMMENTS: I Inspector: [Receipt No.: INSPECTION RECORD Retain a copy with permit Date : PERMIT NO. (206). 431 -3670 9 $42:00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite100. Call to schedule reinspection. Date: Project: - 1 - /Le G •OLLILE Type of inspeytion: r, r/i/,c:llwTI Date called: 1— to Addre s: � Special instructions: Date wanted: a.m. Requester: c i,) � Il IU Ilk Phone No.: ,.1D i'31- g 33L INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.,. #100, Tukwila, WA 98188 Approved per applicable codes. Vi Corrections required prior to approval. COMMENTS: A Pivo ( r s n Pa A. Nr"w1 S t t.1�L. Inspector: INSPECTION RECORD Retain a copy with permit C" %-)C PrPv Date: Date: o31af PERMIT NO. (206) 431 -3670 $42.00 • REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: December 20, 1999 City of Tukwila John W. Rants, Mayor Department of Community Development ::. Steve Lancaster, Director Chuck Mahlum 16000 Christensen Road Tukwila, WA 98188 RE: Permit Status D97 -0364 16300 Christensen Road Dear Mr. Mahlum: In reviewing our current permit files, it appears that your permit for a tenant improvement issued on January 5, 1998, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any-time after the.work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, 4 WiIL > Holt Permit Coordinator Xc: Permit File No. D97 -0364 Duane Griffin, Building Official ;Jr, .1 it 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 INSUFFICIENT ADDRESS RETU5i1 TO SENDER City of Tukwila Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188-2599 E 6/ u Z Chuck Mahlum 16000 Christensen Road Tukwila, WA 98188 IAI d lb 6 V AV&V.V. SVP \ ..... WM/ (,) P 1 d 21 DE041 orxh.. /89 "" 81035 PS METER tr. S. PO Project Info Project Address i /7 646760 A !!DD ! Allowed Watts per ft " Date / / / . ;/7'6 J/ i 1� la Pi� For Building epirrttme nt Use I lLo &)cat' �'(1tsw, ILA 0 �JJ u n 0 1997 P Rh+f CENTER , Applicant Name: (■Cs �fi ?a `A Open Parking Applicant Address Afm C.. /P� avegS.EA, 1 0.„ , CL ,,! 0.2 W /R r Applicant Phone yo? „ 433 4 Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in R' Allowed x Area Covered Parking 0.2 Wlft Open Parking 0.2 W /R Outdoor Areas 0 2 W/ft _ Bldg. (by facade) 0.25 W /ft 7 5 WAf ^� Bldg (by perim) Note for building exterior, choose either the facade area or the penmeter method, but not both) Total Allowed Watts • '• From Table 15 -1 (over) - document all exceptions taken from footnotes Total Allowed Watts Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking 0.2 Wlft Open Parking 0.2 W /R Outdoor Areas 0 2 W/ft _ Bldg. (by facade) 0.25 W /ft 7 5 WAf ^� Bldg (by perim) Note for building exterior, choose either the facade area or the penmeter method, but not both) Total Allowed Watts • Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Location Description Allowed Watts ' per n or per if Area in 11 (or It for perimeter) Allowed Watts x 11 (or x If) Covered Parking 0.2 Wlft Open Parking 0.2 W /R Outdoor Areas 0 2 W/ft _ Bldg. (by facade) 0.25 W /ft 7 5 WAf ^� Bldg (by perim) Note for building exterior, choose either the facade area or the penmeter method, but not both) Total Allowed Watts r Location v v Fixture Descnption Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts 1994 Washin Lighting Summary LTG -SUM 1 994 Washington State Nonres,aennai Energy Coae Compnance Forms P 3G _d) State NonreFi 1ential Ener• CocL...a;om•Hance Form April 1994 Project Description I ❑ New Budding ❑ Addition Alteration Compliance Option ❑ Prescriptive ❑ Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans ) Alteration Exceptions (check appropriate box) Ar No changes are being made to the lighting ❑ Less than 60 % of the fixtures are new. and installed lighting wattage is not being increased Maximum Allowed Lit;htinz± Wattage (Interior Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Maximum Allowed Lighting Wattage (Exterior Proposed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior) Use' LPA (W /ft') Use LPA' (Wife) Painting. welding, carpentry, machine shops 2.3 Police and fire stations 1.2 Barber shops, beauty shops 2 Atria (atriums) 1 Hotel banquet/conference /exhibition hall" 2 Assembly spaces ° , auditoriums, gymnasia', theaters 1 Laboratories 2 Process plants 1 Aircraft repair hangars 1.5 Restaurants/bars 1 Cafeterias. fast food establishments 1.5 Retail A 1 Factones, workshops, handling areas 1 5 Retail B Retail banking 1.5 Gas stations, auto repair sh2s • 1 5 Locker and/or shower facilities 0.8 Institutions 1 5 Warehouses", storage areas 0.5 Libraries 1.5 Aircraft storage hangars 0.4 Nursing homes 1 5 Parkinjgarages s« s'°'°' 1112 Wholesale stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools buildings, school classrooms, day care centers 1.35 Common area, corridors, lobbies (except mall concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.2 Prescriptive Spaces Occupancy ❑ Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note. If occupancy type is "Other and fixture answer is checked. the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. tf not qualified. do LPA Calculations. Lighting Fixtures: ❑ Check here if at least 95% of fixtures in the space meet all four criteria: 1 Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -5, T -6, T-8 or PL, and 3. Lamps.are 5 -50 Watts, and 4. Ballasts are electronic ballasts • oft 1994 Washin to Nonresidential Ener. Code n fiance Form Lighting Summary (back) LTG -SUM 1994 Washington Stale Nonresidential Energy Code Compliance Forms Apo 1994 Table 15-1 Unit Lighting Power Allowance (LPA) for Interior Lighting Footnotes for Table 15-1 I. in cases in which a use is not mentioned specifically. the I 'rrir Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use speci lied in the table. See Section 1512 for exempt arcs. 2. The wans per square tool may be increased. by two percent per foot of eeiling height above twenty feet. unless specifically directed otherwise by subsequent lbotnotes. 3 Watts per square !brit ol'room may be increased by two percent per toot of ceiling height above twelve feet. 4. For all other spaces. such as seating and common areas. use the L'nii Lighi Power Allowance for assembly. 5 Watts per square fitut of room may be increased by two percent per foot of ceiling height above nine feet. 6. Includes pump arca under canopy. 7. In eases in which a lighting plan is submitted for only a portion ota Ioor, a Unit Lighting Power Allowance of 1.35 may be used for usable nllicc floor arca and O.S0 watts per square foot shall be used for the common areas, which may include elevator space. lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. It, For the tire engine room. the Unit Lighting Power Allowance is 1.0 wens per square toot. y For indoor sport tournament courts with adjacent spectator seating. thc Unit Lighting Powcr Allowance for the court area is 2.6 watts per square foot. 11) For both Retail A and Retail 13. Tight for free-standing display. building showcase illumination and display window illumination installed within two feet of the window are exempt. Retail A allows a Unit Lighting Power Allowance of 1.0 vans per square foot. Ceiling mounted adjustable tungsten halogen and HID merchandise display illuminaries arc exempt. Retail 13 allows a Unit Lighting Power Allowance of 1.5 watts per square foot. including all ceiling mounted merchandise display luminaries, 1 1. Provided that a Ioor plan. indicating rack location and height. is submitted. thc square footage for a warehouse may be defined. t'or computing the interior Unit Lighting Power Allowance. as the floor arca not covered by racks plus the vertical face arca (access sidc only) at the racks. The height allowance defined in footnote 2 applies only to the Ioor arca not covered by racks. Lighting Permit Plans !VIA WasprIgton 51ste, Energy Code Como wee Forms , ; Checklist . 7 . . , LTG-CHK . . .. : .. . . „ • . • ": . , " - , . . . The folioventinformation a 'necessary to check a lighting permit application for compliance with the lighting requirements in the : ,, , :, •1'.: ' 1994 Washington State Nonresidential Energy COde. -" ' ' ' • ''' -, , , • .'. ",. : . .. , . '...; .:. „ . : . AppliCabilty ;•Corte, ."; „ - ' ion : ir ,. Sect (ccle one) j ..'' ::-, •' I, '.. , r!'" Component . „ : " ''. ' '' - . ,,;:';., ' . , . . Informitian Required ci 1 Location' ., P .. .. en lata Budding Department . ,, ' • ' '• Notes.' :' • LIGHTIN :: CONTR LS,(Section 151 ),.. ,,. , • . . yes no n.a. ; 1513.1 ; Local controUaccess Schedule with type, indicate locations yes no• n a. 1513.2 ' Area controls Maximum limit per switch : „ . ; ;, .;: „ 1513 3 j' Daylight•zone control - ';; Schedule with type and features, indicate locations 2 2 yes ""no ; nra. ,:- ' ' • 'vertical glazing ' ; Indicate vertical glazing on plans . ,.. . yes ; no.; n:a. . : , ' overhead glazing Indicate overhead 'glazing on plans . - yes no ::n:a. 1513.4 . Oisplayaxhibapecial: Indicate separate controls ' • '‘.. ' . ;, . . ..1513.5.'' Exterior shut-off ; Schedule with type and features: indicate location . .. yes:: no; • n.a: : ; ', ': ,;-: (a) timer witiackup Indicate location • • : : ' . ' • ; yes: no. n.a. ; ,' (b) photocell. • , ;:... Indicate location 2 ' ' ..- : - -,;;-:,.'-":•:, ,... '. :; 1513.6 Inter.,auto shutoff . Indicate location ; . , • 2 • ' '' . , yes no:..:n.a. ;'. 1513.6.1 ' (a) occup.; sensors • .. Schedule with Ve and locations . : ,. . .. : • , yes nciti.a. ' '1513.6.2 (b) ; auto. switches:' . Schedule with type and features (back-up, override capability); ,- . ' , . - • : .. - • ,, , -; - ' . ' ::. , 2 •'Indicate sin of zone on plans LIGHTINGVATTAGE (Sections 15'26-22 or:1530-32) 2 2 2 2 • , no ' ; ' ' : yes . Lighting Sum.. Form/ ' ; ' : ,., Completedand attached. ' .. .' fixture types. . i mallasts. warts per fixture . . laps, b ELECTRIC MOTORS (Section 1511)- ,, Schad ,, u , levA 2 h yes no n.a. "::'-; • '' Elec motor efficiency”' MECH-MOT or Equipment Schedule.wrth hp, rpm, efficiency . ,..., ... 1994 Washing( , StateNonresidential Energy Cod( ompIiance Form ; ' • .• ,„ . .•,. . . 94 VVashinglo ltate,Noritetidential 'Energy; Code plianckForm Lighting Permit Plans Checklist 19 Washington State Energy code Comphance Forms . : • • ;•• LTG-CHK . _ Lighting. Requirements. 1013 Lighting Controls • : 9, • /99.9. • 1513.1 Local Control and Accessibility: Each space. enclosed by wails or ceilin P Shall be Provided with lighting centre!' locked timer, photocell, or a combination of finer and photocell. Automatic switChiS Shill also have program back-up capabiNties, which prevent the • loss of program and time settings for at least 10 hcrw if er s, pow is " 1513.6 'Automatic Shut-Off Controls, 'Interior: Office buildings :within that space; The lighting :.controls, whether one or more, shall be • : than 25,000 1t and all school clessrooros shall be equipped with separate capable Of turning off all Nghts Within the space. The controls shall b. . :.:.;.1UtoMitic'eontrolii to shut off the,lightingduring unoccupied hours: readily atcessble: at the point of entry/exit: to personnel . occUpying or .1 .;;?Autemstie„controls may be an occupancy sensor: time switch. or using the space: , :,; ," '; eapible oI athoniatIcallyshutting off lighting... • Exception': The following lighting controls may be centralized in ; :,• :„ , , „ . „ . • : • rimote locations: • = : ' 1. Areas that must be cOntinuoUily illuminated, or illuminated in a • , : „ • : , ,-, • ; '; : — ; • ' '; • „ • : 4,, ..0. Lighting controls for spaces which must be used asi Manner requiring manual operation of the • ; . . • • • Emergency lighting Systems . ; 2. ; Athematic controls: -9 • ';:'• 3. •, Switching fot industrial or manufacturing process facilities as 3. Controls requiring trained operators. - , . , . , . . may be required for production, ,,, • 4. Contols for safety hazards and secunty. : • - : • :: ' 1513.6.1 Occupancy Seniors: Occupancy sensors shall be capable of 1513.2 Area COritreils: The maximum lighting power that may be " . -autoinaticilliturning Off all the tights in an area, no more than 30 minutes controlled from a single switch or automatic control shall not exceed that : ; ;:, after the area has been vacated: ' : • which is provided by a hventy sniper* circuit loaded to not more than:, - 1613.6.2 AuromadiTime SWItches: Automatic time switches shall hairs , eighty percent: A master control may be installed provided the individual • ,! a minimum 7 day clock and be capable of being set for97 different day !: switches ritain their capability to function independently: ,Circuit breakers : .- , : ,- :.' types per week and incorporate an automatic holiday '!Shut7eiff fester., Maynet be used as the sole means of switching. - •• : . '. which turns OH all loads for at least 24 hours and then' resumes normally '.' ' ■ Exceptions:, :.: . . ' .' , : .: . , : 'scheduled operations. Automatic time switches shall also have program 1. Industrial or manufacturing process areei, as may be 'required : ' ' :: - biek...up capabilides. which prevent theross Of Program and time Settings: ':.'.:' .-;• ': . . . . :„ ., _, . , , ,... ,,:..for at least 10 hours. N power iti internroted.' : , ' •'` ' : ". : ' . , '''.1'; .:' • . :" -•'' ' " :''': for Production. '" :: . ' O.... .. • I 2:.• -::: ": Areas les' Automatic s than five percent of the building footprint for - :-.: . ,, : ' :- me switches shall incorporate an over-ride swilching deviCe.L. 1513.3 daylight Zone Control: Alidayighted zones, as defined in •• Chapter,12, both.under overhead glazing and adjacent to vertical b • : is located So that a person using the device can see the light's or the areas controlled by the switch or so that the area being illuminated is annunciated; shall he provided with individual controls, or daylight- or oecupant-sensing automatic controls, which control the lights independent of general are. lighting.. 1513.4 Display, Exhibition, and Specialty Lighting Controls: All display, exhibition, or specialty lighting shall be controlled independently of general area lighting. . , • . • • • . • , ..• ' ,.." c. is manually operated; d. allows the lighting to remain on for no more than two hours when an over-ride is initiated: and e. controls an area not exceeding 5,000 ft or 5 percent of footprint for footprints over 100,000 re whichever 1513.5 Automatic Shut-off Controls, Exterior: Exterior lighting not, greater. intended for 24-hour continuous use shall be automatically switched by .•' ;1994 Washinoo^n State Nonresidential Organization of For ORG 1914 Washington Slate Energy Code Compliance Fors This document introduces the forms to be used . for showing compliance with the 1994 Nonresi- dential Energy Code (NREC). The following fig - ure shows the overall organization of the form set: For simple projects, only a few forms are required; more complex projects will require addi- tional forms. The forms explain the decision cri- teria for determining when a more complicated form is required. Energy Code. Co r'ince Form ':.ABM. MN, All projects should complete the Summary forms which apply (envelope, mechanical and /or light- ing). All projects should also review the Checklist forms to make sure all necessary information on compliance is provided.. Applicable excerpts from the General Requirements sections of the Code are reprinted on the back of the Checklist forms. The need for other forms will be determined by project specifics. ENV Summary Project, information Typed project Compliance opts. Glazing area % Can use simple? Summ. of Req. ENV Checklist What goes on plans? Where it goes Reprint of General Reqmts. Component Performance Worksheet Target & Pro- posed UA Wtd. Avg. SHGC Area Adjustment MECH Summary Project information Type of project Compliance opts Can use simple? Basic equip efficiencies Complex Systems Additional Checklist and decisionmaking for Complex Systems LTG Summary Project information Type of project Compliance opts. Can use most simple? Allowed and Proposed Watts MECH Ckbt What goes on plans? Where it goes Reprint of General Reqmts. LTG ChecMst What goes on plans? Where k goes Reprint of General Reqmts. Motors Checklist For any project with motors cov- ered by 1437 or 1511 Forms List ORG 1994•.Washi .1 State. Nonresidential Energy Code Co " • ''z,nce Form The following is a list of the 1994 nonresidential compliance forms their use.. Envelope ENV-SUM Envelope Summary - Use this form for all projects where envelope work is to be done; there are sepa- rate versions for Climate Zone 1 and Zone 2. Show basic project information, compliance options chosen, summary list of required insulation levels and U- factors. Back side has Decision Flowchart for Prescriptive Option and calcu- lation to determine area weighted Heat Capacity for the Masonry Option. ENV -CHK Budding Permit Plans Checklist - Comprehensive list of all information required on plans for all op- tions, including the Component Performance and Systems Analysis Options. Also includes space for building de- partment notes. ENV -UA Envelope UA Calculations- Use this form if using the Component Performance Option; there are sepa- rate versions for Climate Zone 1 and Zone 2, Summary calculations of Target UA and Proposed UA. Back side has calculation of Target and Proposed SHGC, and calculation of glazing and opaque target area adjustments, if needed. Mechanical MECH -SUM Mechanical Summary - Use this form for all projects where mechanical work is to be done. Show ba- sic project information, compliance approach chosen, list of basic equipment & efficiencies (else this information goes on equipment schedules on the plans). Back side has Decision Flowchart for Simple System option. MECH -CHK Mechanical Permit Plans Checklist - Comprehensive list of all information required on plans for all options, including the Component Performance and Systems Analysis Options. Also includes space for building de- partment notes. MECH -COMP Mechanical - Complex Systems - Use this form if using the Complex Systems Option. Complex Systems Checklist has additional information required on plans for this Option. Decision flowchart is provided for determining which Complex Systems requirements apply to the project. MECH -MOT Electric Motors Checklist for electric motors compliance and schedule of installed motors, both for mechanical systems and other equipment. Lighting LTG-SUMM Lighting Summary - Use this form for all projects where lighting work is to be done. Basic project in- formation, compliance approach chosen, alteration exceptions. Calculations of Allowed and Proposed Lighting Power for both Interior and Exterior Lighting if using the Lighting Power Allowance Option. Back side has questions to determine if project qualifies for the Prescriptive Option. Also has Lighting Power Allowance table /footnotes. LTG -CHK Lighting Permit Plans Checklist - Comprehensive list of all information required on plans for all op- tions, including Component Performance and Systems Analysis. Also includes space for building department notes. Fire Department Fire Department Review . Control # Dq7 .-03(/ Re: T.I. at T C�j . Dear sir: / 63oO Chrii tc/1 kx.,PU Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 11 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4,3) Every six years, dry chemical and John W. Rants, Mayor AMMO Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) .57$ 4404 • Fax 206 57.5-4439 Page number Thomas P. Keefe, Fire Chief halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are l-leadquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) .575-4439 Page number. 3 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3), Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) 7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206 5754439 nl:Cfi'A. EGi•4a:L. 2 1,∎' I,J !NF)i�Skil' "!ri'Mw'�IiCMG"I Page number City of Tukwila Fire Department 9. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. Ali new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required .fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 57;4404 • Fax John W Rants, Mayor Thomas P. Keefe, Fire Chief In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) John W. Rants, Mayor Thomas P. Keefe, Fire Chief requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East ti Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) .575-4439 Headquarters Station: 444 Andover Park East • Tukwila, Wasldngton 98188 • Phone: (2061 574;.4404 • FAX PON 57.5,4439 r-,DETACH • TO DISPLAY CERTIFICATET DETACH TO DISPLAY' .CERTIFICATE-..J GENERAL NOTES 2 25 s' T.CN SI)AL: LLSAPI WIT •HE '.Y9i 1NIF.`PM Ili .1 ..`LNG • �.I NAti. SATE REC,Du Tr `N FOR BARRIER FREE DESIGN AMERICANS WI', L ISABI U'E S AC' WASHINGTON STATE ENERGY 'ODE L'NSOIRM PLUMBING co, ANL As AFT; Il ABLE LOCAL ,IDES ORDINANCES AND STANDARDS C..N7F3q!: TOP IS TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS DES.. E N AND Neu,. THE DESIGNER OF ANY AND ALL DISCREPANCIES PRIOR TO PRO, EDIN3 wRH THE WORK T r_.N TRACTOR SHALL VERIFY ALL U AN 'BLDINO STDARDS' WITH BUILDING LANDLORD PRIOR BEGINNING ANY WORK HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE DESIGNERS WRIT TEN APPROVAL THEREOF THE CONTRACTOR AGREES TO DEFEND, INDEMNITY AND HOLD THE DESIGNER HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND ALL AREAS SHAL, BE LEFT IN A CLEAN BROOM) CONDITION 5T AU TIMES APPROVED PLANS SHALL KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS. ADDENDA. AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION. ONE COMPLETE SET OF PLANS WITH AL: REVISIONS. ADDENDA. ABS CHANGE ORDERS. ON THE PRMEM.ISES A T ALL TIMES WHICH ARE SD UNDER THE CARE OF THE JOB SUPERINTENOENT ALL OPERAROHS CONDUCTED ON THE PREMISES St-MALAISE BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY UN. 6Y REASON OF NOISE, STEAM, ODOR FUMES GASES SMOKE. VIBRATION, HAZARD OF OTHER CAUSES IN ADOTTTCN, THE CONTRACTOR SHALL MINIMIZE DISRUPTIONS OF ADJACENT TENANTS DUE TO NOISE, ODOR CORRIDOR FUMES, OR VIBRATION ALL COMMON LOBBY AND CORRIDOR SPACE SHALL BE KEPT CLEAR OF DUST DEBRIS, AND CONSTRUCTION MATERIALS AT ALL TIMES ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST RECCAGMENDATIONS OR WRITTEN DIRECTIONS ALL DIMENSIONS ARE FACE OF . PIL.A AA, , ,. HT UNLESS OTHERWISE NOTES: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK 'HE DETAILS SHALL BE THE SAME AS FOR OTHER SIW LAR WORK IN THE SAME BUILDING • o wHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR 1T IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICE ITEMS OR PARTS AS ARE REWIRED TO PROPERLY COMPLETE THE W0115 IT SHAD: BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL HOSTING UTILITIES WHETHER SHOWN HEREON OR NOT ANO TO PROTECT THEM FROM DAMAGE THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJLICTION WRH THE EXECUTION OF HIS WORK. THE CON t.CTOR WILL VERIFY AND CONFORM TO ALL RB)]DHREMENTS OF ALL LJTRTTY COMPANIES UNLESS OTHERWISE NOTED IN THE NS AND SPECIFICATIONS THE CONTRAC TOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE 1 HE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMER '4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BLEEDING ANC SITE WHK.E JOB tS IN PROGRESS AND UNTIL THE JOB IS COMPLETED ALL WORN SHALL BE ADARANTEED FOR A PERIOC OF ONE III YEAR AFTER COMPLETION. UNLESS OTHERWISE SPECIFIED. AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT ALL REPAIRS. CORRECTIONS AND DISCREPANCIES ETC . MUST BE MADE WITHOUT ANY ADDITIONAL COSI TO THE OWNER AND WITHIN FIVE (5) DAYS AFTER NOTICE IS SNEN LATHING PLASTER, AND GYPSUM WALL BOAR° SYSTEMS SHALL CONFORM TOT LIE CHAP rEP 250E THE 19W U B.0 ALL EXPOSED GYPSUM BOAAO TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER. OF THE 1.641u B AND THE U S. PRODUCT SAFETY COMMISSION SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIPC RATING. 20 EXIT SIGNS AND ILLUMINATION SHALL CONFORM TO THE 199'1 U 6 C CHAPTER 10, AND LOCAL FIRE MARSHAL REOUBREMENTS. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATIONS WITH ARE MARSHAL_ CONTRACTOR TO SUPPLY FIRE EXTINGUISHERS AND CABINET AS REQUIRED 21 ELECTRK;AL RG OH.IN AND REFLECTED CEKJNG PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED 24 FLAMMABLE UOVIDS SHALL NOT BE PLACED STORED. OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN N FP A STANDARD 30 AND THE CURRENT 0441F051A FIRE CODE PERMIT MAY BE RE'OUIRED. ALL DRAPES, HANGINGS. ANDCURTNNS. DROPS ANO ALL OTHER DE MATERAL INCLUDING CHRISTMAS TREES THAT WOULD 7END'C INC THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NON.FLAMABLE MATERIAL OR SHALL BE TREATED AND MAINTAINED IM A FIRE RETARDANT CONDITION BY MEANS OF A FT AME RETARDANT SOLUTION OR PROCESS APPROVED BY THE COUNTY FIRE MARSHAL. PROVIDE A CERTIFICATION TO THIS EFFECT A EXIT DOORS. EXIT LIGHTS, AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL MINIMUM FLAME SIRE II' CLASSIFICATION OF INTER10R FINISHERS SHALL BE PER TABLE 9 -B OF THE I1).4 U B.0 213 ALL LAY IN ACOUSTICAL CHLNG GRIDS SHALL BE INSTALLED AND SECURED PER 19. U B U SECTION TRH. STANDARD Sb, FOR EARTHOL/AKE ZONE II PROVIDE OR MODIFY AS NEEDED SPRINKLER, ALARM AND SMOKE DETECTION SYSTEM PER ALL APPLICABLE CODES, INCLUDING IF NECESSARY RAE HORNS STROBE LIGHTS CONTROL PANEL CONNECTIONS. SMOKE DETECTORS. AUDIO VISUAL ALARMS SUBMIT O SHOP DRAWINGS TO THE FIRE MARSHALL FOR APPROVAL 26 TENANT TO PROVIDE AND INSTALL THE TELEPHONE AND DATA COMMUNICATION CABLING. CONTRACTOR TO COORDINATE SCHEDULING AND OTHER REQUIREMENTS WITH TENANT 29 MECHANICAL SYSTEM. CONTRACTOR SHALL VERIFY AND PROVIDE A COMPLETE `NAC SYSTEM WHICH CONFORMS TO THE OWNERS HVAC SPECIFICATIONS CONTRACTOR SHALL BE RFSPONSt&1 FOR ALL ROOF PENETRATIONS AND PATCH- ING ANY SCREENING OF ROOF- MOUNTED MECHANICAL UNR REQUIRED BY GOVERN INS JURISDICTION 10 PROVIDE OR ).1001, AS NEEDED EMERGENCY LIGHTING ALL ITEMS MARKED' N I.C.' ARE NOT PART OF THIS CONTRACT. 32 ABBREVIATIONS THROUGHOUT THE PLANS ARE MBFEVIATION9 WHICH ARE IN COMMON USE THE LIST OF ABBREVLATIONS PROVIDES 19 NOT INTENDED TO BE COMPLETE OR REPRESENTATIVE OF CONDITIONS OR MATERIALS ACTUALLY USED ON THE PROJECT 'HE DESIGNER WIL) DEFINE THE INTENT OF ANY IN QUESTION ABBREVIATIONS A T AUJ P APVD ADC'- Bl K BI C<J CI KG COl CONS COHST DON TR CPT CW DEPT DET NAG DIA DIM DWG ELEV EL EC EO SOP' EXIST F F. FL FCIL. GL GWB ID WO HT H W !NCO 'NCI INTR JT LAM LTG SITE PLAN ACOUSTIC ACUIISTIDAL ACOUSTICAL TILE ADJUSTABLE ADJUST ACCESS PANEL APPROVED ARCHITECTURAL BLOCK BLOCKING BUILDING CENTER I INE CAUL KING COLUMN CONTRETE CONSTRUCTION CONTRACTOR CARPET COLD WATER DEPARTMENT DETAIL DIAGONAL DIAMETER DIMENSION DRAWING ELEVATION(BLDG) ELEVATOR ELECTRICAL EQUAL EQUIPMENT EXISTING FURNISHED A INSTALLED BY OTHER FINISH FLOOR FURNISHED BY OTHER INSTALLED BY CONTRACTOR GLASS: GLAZING GLAZED GYPSUM WALL BOARD HARDWOOD HEIGHT HUT WATER INCANDESCENT INCLUDE INTERIOR JOINT LAMINATED. LAMINATE LIGHTING 1 IGH MAT MAX MFD MFR. MIN MISC MID MTL N NTS OC PT PART PPL PL. P LAM PLY Q. R B REF RECD REV R SECT SHT SIM SPEC SST STD STOR STRUC SUSP SW TEL TEMP TYP VAR VCT VERT V,P W.8 W WD WT MAT EISAI MAXIMUM MANIIFAI;rt IRED MANUFACTURED MINIMUM MISCELLANEOUS MOUNTED METAL NOT IN CLINTHAC I NOT TO SOAI E ON CENTER PAINT PARTI'IC N POLISHED PLATE GLASS PLATE PLASTIC LAMINATE Pt YWOCID QUARRY TILE RUBBER BASF REFERENCE REQUIRED REVISED REVISION ROUGH OPENING STAIR SECTION SHEET SIMILAR SPECIFICATIONS SPEC .ELI STAINLESS STE: STANDARD STORAGE STRUCTURAL SUSPEND SUSPENDED SWITCH TELEPHONE TEMPERED TYPICAL VARIABLE VARIES VINYL COMPOSITION T I) E VERTICAL VERTICAL L VENEER F'I.AST I(' WOOF) BASE WATER I:UVERING WOOD WEIGHT CONTRACT THIS AREA PROJECT ADDRESS GOVERNING CODE. USE ZONE OCCUPANCY CONSTRUCTION TYPE ENERGY CODE CODE. CONTRACTOR MECHANICAL. ELECTRICAL: SPRINKLER SYSTEM. TENANT AREA PARCEL I 9EN NOAH ;D DL i p PROJECT DATA LEGAL DESCRIPTION I V E R 16300 CHRISTENSEN ROAD TUKWILA WA 98188 1994 U B C (STATE OE WASHINGTON AMENDMENTS) 8 1993 WASHINGTON STATE ENERGY CODE 1994 U. P. C. TO BE DETERMINED PRIOR TO PERMIT ISSUANCE BIDDER DESIGN (UNDER SEPARATE PERMIT) BIDDER DESIGN (UNDER SEPARATE PERMIT) BIDDER DESIGN (UNDER SEPARATE PERMIT) 1172 U.S.F. • DRAWING INDEX s w...w ..> a .�..r ..e.e.. VICINITY MAP T 1 COVER SHEET A-1 DEMOLITION /PA RTITION PLAN REFLECTED CEILING PLAN ELECTRICAL PLAN PARCELS 2 3 & 4 a IS: DI Date Permit No. SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL EIELECTRICAL ❑ PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION FILE COPY AL' .. _ omissions T p:.:. 1,3 not authorize the Violation cf L. aV_PIeI code OT WmIE@Ilap INIO0044 of Con copy cf approved periedialftlediged. EDEWED C17Y B OF TIIV` NOT T5; PERM'" REVISONS NO CHANGES SHALL BE MAfDE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OF TUKWILA BUILDING DIVISION. NOTE REVISIONS WILL REQUIRE A NEW Sues TT:,L AND MAY INCLUDE ADDITIONAL PLAN REV FEES. D 7-o36 CDG III tiN( I)) S)IIN 22000 64TH AVENUE WEST, SUITE 2F ILI `INL. + 197 ISSUED TOR RERMIT ,CVI N I ;HFE T 97308 „L LOnflO,il 0F`OIJ0 DOOR SCHEDULE u II DEMOLITION /PARTITION PLAN SCALE: I /5" = 1' -0" DEMOLITION NOTES WHERE DEMOLITION OCCURS, ALL REMAINING WALLS ARE TO BE PATCHED, SANDED SMOOTH AND PREPARED FOR FINISHING AS REQUIRED. REMOVE EXISTING FLOOR FINIC.I EG. PATCH AND PREPARE FLOORS AS REQUIRED FOR SMOOTH, LEVEL FINISH. AT N PATCHED. SMOOTH AND PREPARED FOR WALLS BE AS REQUIRED. WHERE NEW PARTITION MEETS EXISTING FURRED COLUMN OR GORE WALL, RF<O E R BEAD, ALIGN, TAPE AND SPACKLE NEW PARTITION TO EOARD Au CONSTRUCTION TO REMAIN AND AFFECTED BY DEMOLITION SHALL BE PATCHED A ET SPACKLED AND BE PROPERLY MEMBERED AND ALIGNED 50 AS TO LEAVE NO EVIDENCE OF PATGHINS OR REPAIRS. EXISTING ELECTRICAL AND TELEPHONE OUTLETS LOCATED ON DEMOLISHED WALLS S ARE TO BE REMOVED INCLUDING CONDUIT AND WIRING BACK TO .JJNGTION SOX. LOCATIONS ARE TO BE PATCHED AND REPAIRED TO SE FLUSH WITH ADJACENT WALL SURFACE. WHLFC PLUMBING FIXTURES ARE BEING REMOVED OR WHERE EXPOSED P P A LTSI G AND REPAIR AS IDES OCCUR, C RE P LINES BEHIND FINISHED SURFACES ALL EXISTING CONSTRUCTION MERE INDICATED INCLUDING ELECTRICAL, TELEPHONE, PLUMBING AND MECHANICAL DEVICES NOT OTHERWISE INDICATED ON THESE CONSTRUCTION DRAWINGS SHALL BE REMOVED N A CAREFUL MANNER SO AS NOT TO DAMAGE ADJOINING CONSTRUCTION. PARTITION NOTES OONTRAOTOR TO VERIFY ALL DIMENSIONS. ALL DISCREPANCIES MUST SE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DIRECTION. PARTITIONS, WTiMETAL STUDS AT 2 0 OTHERWISE ., ITH 5/H TYPE CONSTRUCTED PE 'X' GYPSUM WALLBOARD EACH SIDE. THERE SHALL BE NO EXPOSED PIPE, CONDUIT DUCTS, VENTS ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED CONSTRUCTION ON DRAWINGS. OFFSET STUDS, WHERE REQUIRED, SO THAT FINISHED PARTITION SURFACE WILL SE FLUSH, UNLESS OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE SIX ION. INCHES PROM FACE AT HINGE SIDE OF DOOR TO ADJACENT PAR ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT PROVIDE SHEET METAL. REINFORCING (5" HORIZONTALLY MOUNTED STRIP OF 20 GA. GALVANIZED SHEET METAL) IN PARTITIONS FOR INSTALLATION OF WALL HUNG CABINET WORK AND PANELING WHERE INDICATED ON DRAWINGS INCLUDING ALL OWNER PROVIDED ITEMS. CONTRACTOR TO VERIFY DIMENSIONS FOR ALL PLUMBING PARTITIONS. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DESIGNER AND TENANT APPROVAL PRIOR TO MANUFACTURE OF ANY CABINET WORK MILLWORK, AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FUSRICATED WORK. PARTITION LEGEND DEMOLITION EXf5TIN5 PARTITION TO REMAIN 5/5 TENANT PARTITION - B/5 METAL STUDS s 24 "O.C. WITH 5/8" TYPE ON BOTH SIDES FROM FLOOR TO UNDERSIDE OF HUNG CEILING C - DOOR NUMBER /- TYPE OF DOOR i A. B/5 5' -O x B/5 HEIGHT BI -FOLD DOOR IN B/5 FRAME S. 5/9 5' -0" X 15/5 HEIGHT DOOR IN B/S FRAME HARDWARE a. B/S BI -FOLD DOOR HARDWARE b 13/5 LATCHSET NOTE CONTRACTOR TO REUSE AND RELOCATE EXISTING DOORS AND HARDWARE WHERE FOSSIBLE ALL NEW HARDWARE TO BE LEVER 5,LE �® N x GWB KEY NOTES IF II SCALE, I/5" = 1' -0" ELECTRICAL PLAN I. ALIGN FINISHED SURFACES. 2. ALIGN AT CORNER. 3, RELOCATE EXISTING SINK, BASE d UPPER CABINET, PROVIDE B/5 P -LAM COUNTERTOP I BAACKSPLASH AND PLUMBING. 4. PROVIDE NEW STORAGE CABINET TO MATCH EXISTING. ELECTRICAL NOTES. ALL WALL MOUNTED TELEPHONE AND ELECTRICAL OUTLETS TO BE INSTALLED 15" ABOVE FLOOR UNLESS OTHERWISE NOTED. ALL/ANY CORE DRILL LOCATIONS SHALL BE VERIFIED WITH DESIGNER PRIOR TO DRILLING. ALL UNUSED CORE DRILLS SHALL BE PLUGGED AND CAPPED AS REQUIRED TO MAINTAIN FLOOR FIRE RATING. ALL TELEPHONE AND COMPUTER WIRE-5 SHALL BE PULLED BY TENANT'S CONTRACTOR UNLESS OTHERWISE NOTED. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL WIRES AND BOXES AT EACH LOCATION. ELECTRICAL LEGEND 0 DUPLEX RECEPTACLE OUTLET 4* DUPLEX RECEPTACLE OUTLET - DEDICATED CIRCUIT 12OV, 2OA WALL MOUNTED B/S FOURPLEX RECEPTACLE OUTLET Q WALL MOUNTED 5/5 TELEPHONE OUTLET • WALL MOUNTED B/5 DEDICATED TELEPHONE/FAX/DATA OUTLET Q WALL MOUNTED B/S COMBINATION TELEPHONE/DATA OUTLET E EXISTING "0 REMAIN R RETROFIT EXISTING OUTLET NOTE CONTRACTOR TO REUSE AND /OR RELOCATE EXISTING ELECTRICAL I TELEPHONE OUTLETS WHERE POSSIBLE. ALL EXISTING TING ELECTRICAAIN TO REML/TELEPHONE OUTLETS NOT ARE EXIS. LIGHTING NOTES PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS, OR DUCTS PENETRATING FIRE RATED ASSEMBLIES, ENCLOSURES, WALLS, FLOORS, OR SURFACES, AND AS REQUIRED SY FIRE DEPARTMENT. CONTRACTOR SHALL OBTAIN APPROVAL FROM DESIGNER OF ALL THERMOSTAT LOC ATIONS. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND SHALL CONFORM WITH ALL APPLICABLE CODES. CEILING HEIGHTS ARE FROM SLAB TO FINISHED CEILING. LIGHT SWITCHES SHALL BE INSTALLED AT .45" A.F.F. MULTIPLE SWITCHES SHOULD BE GANGED TOGETHER UNLESS OTHERWISE SPECIFIED. CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING, .STROBE LIGHTS, AUDIO- VISUAL ALARMS, TO MEET ALL APPLICABLE CODES. LIGHTING CALCULATIONS ALL EXISTING LIGHT FIXTURES TO REMAIN WITHIN TENANT SPACE, NO PROPOSED CHANGE IN ENERGY USAGE. LIGHTING LEGEND I I /7 - Q3($f EXISTING B/S 2 x 4 FLUORESCENT LIGHT FIXTURE TO REMAIN RELOCATED EXISTING B/S 2 x 4 FLUORESCENT LIGHT FIXTURE EXISTING 24 HOUR FIXTURE TO REMAIN • B/5 SINGLE SWITCH E EXISTING TO REMAIN NOTE: CONTRACTOR TO REUSE AN/OR RELOCATE EXISTING LIGHT FIXTURES AND SWITCHES WHERE POSSIBLE CO O TO R / RECIRCUIT LIGHT SWITCHES AND LIGHT l l II SCALE: I/S' 1'-0" REFLECTED CEILING PLAN 45- ..811111111117 W911WW11111118$11111E:.. FOAM TAPE U __SC TR REWED TO TRACK AT 24° O G. CONTRACT THIS AREA It BRACE TO STRUCTURE ABOVE AT S' -O° MAX W,' MTL. STUDS ACOUSTICAL j CEILING TILE CONT. "L" METAL TRIM W/ PAPER WING CONT. 114" 20 GA. TRACK W/ 2 - 10 SCREWS AT 24" 0.0 25 GA GALV MTL. STUD AT 5 /5" THK. FIRE RATED GYPS, IJM BOARD (ONE HOUR CONSTRUCTION) CONT. 25 GA. GALV STL. RUNNER CHANNEL AND ANCHORED TO FLOOR W/ POWDER ACTIVATED FASTENING SYSTEM AT 24" O.G SECTION - BUILDING STANDARD PARTITION SCALE: N.T.S. FECEND CITY OF TU 3) . 199 PERT. CFI' - 01 171 i 97908 EW III III I11 HI wismorse e s i g n C design group PLANNING CJC. DESIGN INCORPORATED )5Q4) 142`.6'':,- F''LE I 1/-1197 ISSUED FOR PERMIT DEMO /PARTITION/ ELEC./ REFLECTED CEILING PLAN AMB