Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D97-0388 - BOEING #21-05 - FENCE, GATE AND DOOR
City of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 102304 -9069 Address: 3417 S 120 PL Suite No: Location: Category: AWSE Type: DEVPERM Zoning: MIC/L Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: 125 Sewer: VAL VUE Wetlands: Slopes: Y' Contractor License No: BOEINC *294ML BOEING' #21 -05 3417•S 120 PL, TUKWILA WA 98168 THE BOEING COMPANY PO BOX 3707 M/S 1F -09, SEATTLE WA GARY TALLER PO BOX 3707 MIS 46 -87, SEATTLE WA 98124 CONTRACTOR BOEING COMPANY P.O. BOX 3707, M/S IF -09, SEATTLE, WA 98124 **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALLATION OF 120 SF OF SHOP FENCE, GATE. AND, DOOR. **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ ' 7,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Curb Cut /Access /Sidewalk /CSS: 'N Fire Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving, Oversized Load: N Start Time: End Time;: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 210.34 ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** m*********** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** OCCUPANT OWNER CONTACT Permit Center Authorized Signature: Signature: Print Name: DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: Status: Issued: Expires: Streams: End Timer Fill: Date: (206) 431 -3670 D97 -0388 ISSUED 01/09/1998 07/08/1998 Occupancy: WAREHOUSE UBC: 1994 Fire Protection: SPRINKLERED /AFA East: .0 West: .0 Phone: 206 544 -2975 Eng. Appr: Size(in): .00 Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work, am authorized to sign for and obtain this development pei This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. TUKWIL Addr 34'1.7 S ' 140 PL Permit No 097 03,88 Suite; Tenant, Status ISSUED; Type, D,EVPER1!4 Ap:p l i d 12 f 1.1 / 997 oriel # 10 304 906 Issued 01 /09 /.1998 k 4. * k * k*k k *,kh*k* '.k* *'* : k* it** k:* k ******* ; *kkk * * *kA *A'A•N * **A *kk.k: *A. N•Ar•k•hA,k;k;k:•k • ermi t tCond i;t ion 1' No . wi 11 be: made ta the plans ' unless approved fay the Ar chitect or Engineer and' the.. Tula. ti la 13ui ldi Division 2 All per miis ins pect ion ecords -an i iappro plans ,shall ava`i lab;le at this` labtstte prior tip the start ;o any c o n` str.uct i:on The e do'cu ar a to be ma rata fined and .0 : i•1 able unti 1 final in:.pectio i, appr Dual i. grarl,ted -' Y 3 All construction toy b`e done in� c'onfdrmance 't�llt`h approved pla "ns and �,r egui remerit� - of the lan ifor m Bu l l d ng +Code U994 Edition) s amen,ded "11.1nifi:or m Mechanical Code X1 94 Edit and 41as,bj ngtnn Statc Energy ,ode?,{ (19 4 E d Pe.rson:ri'e,1 gate is the requii�e�d e.r,it the space dero.is�e; bey th yi ence } `Cons'c ; qu'entl�,. Arty : ng 5or : loc�kling har dw K r r mint 01 with th e r e quirm6nts� atc Cxi r �dgor ha1;l he, op,ehab le1 from th inside -wi thout e of!, . eY t any sp krio'V�1ed e}or' effor.t.' 'Ja l h i ty"'off Per,mi t The ssu.anc oaf a perm ► t , or approval plays, pecifica and comp hal1 • not be co.p titr iea to t; a permit for » o ari 'apprfoval "of any ; �rrol tior $ ny +at„ ile f'<t b ri�7 3ng ,code'or o f and k otherl o;► d 1'40 e fat they l,ub i sd i eti„Op f:Ko :.p .i pr esun►i,ng g ive,'author tty to } or, � ancel the provisions of • this; cad F { :.h all :be 'va l i d,� r i Project Name/Tenant: BOEING BLDG . v ./'05 Value of Construction: fr " , noo, Proposed use: El Retail El Restaurant ❑ Church Manufacturing ❑ SchoolCollege /University Site Address: j 1-7 J fan PI City State /Zip: Tax Parcel Number: U`(^ 296 Will there be a change of use? El yes C no Property Owner: THE BOEING COMPANY Phone: • Street Address: P.O. BOX 3707 M/S 46 -87 SEATTLE lK / i$124 F � ax n #: Will there be storage of flammable /combustible hazardous material Attach listof materials and storage location on separate 8 1/2 Contact Person: GARY TALLER /G E7�� 1� /D- C.E�2� P ZU�e =544 -2975 /ZGIo'&55•Z48fo Street Address: City Slate/Zip: P.O. BOX 3707 M/S 46 - 87 SEATTLE, WA 911121 Fax #: 2 06 - 544 - 2854 Contractor: NSo r i:ZN ()— Phone: Street Address: City State /Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax it Engineer: Phone: ' Street Address: City State /Zip: Fax It: Description of work to be done: I115TAJ .L 12o ►..i✓. OF SMOP Fa4C r t; Et). 444 c. * _ . Existing use: C:1 Retail ❑ Restaurant El Multi-family El El Hospital ❑ Church Manufacturing ❑ Motel/Hotel 0 ❑ School /College /University El Other Proposed use: El Retail El Restaurant ❑ Church Manufacturing ❑ SchoolCollege /University El Multi - family 0 El Hospital El Motel /Hotel Office ❑ Other Will there be a change of use? El yes C no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? El yes l r no Existing fire protection features: automatic fire alarm El none El other (specify) Building Square Feet: . 101, 414, 4 existing I Area of Construction: (sq. ft.) 3,000_ Will there be storage of flammable /combustible hazardous material Attach listof materials and storage location on separate 8 1/2 in the building? El yes L`7 no X 11 paper indicating quantities & Material Safety Data Sheets Commercial / Multi - Family Tenant Improvement / Alteration Permit Application ❑ Channelization /Striping El Land Altering 0 Cut ❑ Sanitary Side Sewer #: El Storm Drainage CITY OF T'IKWILA Permit Centert,. 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 .IOR M Iw7I' 7 -Oct El Water Meter /Exempt #: Size(s): El Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): El Miscellaneous CTPFRMIT.DOC 7/9/96 APPLICANT REQUEST, FOR PUBUC;:,WORKSiSITE /CIVIL'.PLAN- REVIEVOF THEsFOLLOWIN (Additional reviews may be.deterinliied -by`the Public Works Department) Est. quantity: Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ❑ Curb cut/Access /Sidewalk El Flood Control Zone ❑ Hauling cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation El Sewer Main Extension 0 Private 0 Public ❑ Street Use El Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only 2/0 .3L4 gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Oat j 2 - 1r q 7 or Date F a rt plres Cil -- BUILDING OWNS OR AUTHU: ' GEN- T: ---- - Signature: /J/ ,/ � Date: /� /, Print name: - GI RY .T ALLER t, .1 ,, 1Phone:206- 544 — %975.+• Fax II:2g Address : 1;D 3707 M 46 -87 City /State /Zip SEATILE, WA 4812 ALL COMMERCIAL/MULTI -FA TENANT IMPROVEMENT /ALT: TION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: f ➢ cr, A LL•DRAW,ING S' Te) BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification If there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : ❑ El Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas • 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as Identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. ❑ El SEPA Checklist - if intensification of use (check with Planning Department for thresholds). El ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) El ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ". Building Owner /Authorized Agent if the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 7/9/96 City: of Tukwila Fire Department TURWILA FIRE DEPARTMENT :FINAL APPROVAL FORM j )�_ C " Project Name Lx,.�CW1cj. .3M 5 1 Z�` PL Address Retain current inspection schedule Needs shift inspection Permit No :' Approved without correction notice Approved with correction notice issued Sprinklers: S Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 31 Lt.A °,) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575 -4439 . .."..1:1,:eC4' 4 i!.,■4L:P..;; ; +...1%fr.' ' '44 t ;'..;;;;tt2 4c*;1,1t*i A**14Ali.VA ;V4viic t****1 4.* :IN * k 1.1t.71-7k Alk4 1 TRANSMIT • k*:* k ***Alt;k410 Number' : 210..34 12/11/97 14:39 0 aYglertlethod : :CHECK Notation: c1RY TLI „ ER i i; KJP •-• 7••••• a. a* a 4. • "."• • a' - "a "• •” " " •! •.* -- 7.7 7 Permit No: D'37-0388 Type: DEVPERM DEVELOPMENT PE:KNIT Parcel No 107.304-9069 Site Ai/dress: 3417 $ 120 PL Total Fees: 210.34 This Payment 210.34 Total ALL Pmts: 210.34 Dal ance: .00 , 4*4*,4**.A*A*1*)..* Account Code Descri pt ion 000/322..100 Hi/ICING NONRES 000/345.830 PLAN CHECK •-• NONREG, 000/086,904 STATE BUILDING SURCF1ARGE A m eit nt 124.75 81.09 4.50 6737 12/12 9717 TOTAL 23.0.34 .• • • ^ , • •• . • • ,, , Project: Addres COMMENTS: Inspector: I I • INSPECTION RECORD Retein a copy with per INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 5 i2a PI Special instructions: re.-- 312-fa Cull Date wanted: Date: )03: Type ins ion: Date called: . 3 zq_e 3 -24,18 Requester: in r vk.ar Pho 7: tv pet Approved per applicable codes. I 1 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspect on, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: PERMIT NO. 431-3670 .M: Project: Type of inspecti • Address: Date calledL Special instructions: c I.-- 414/X 1 Date wanted: 3.4... Requester: Phone No.: Inspector: Date: INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.,. #100, Tukwila, WA 98188 • L r AApproved per applicable codes. INSPECTION RECOR Retain a copy with per PERMIT NO. 206) 431 -3670 Corrections required prior to approval. 4 $42.00 REINSPECT! • FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: tioatniar ACTIVITY NUMBER: D97 -0388 PROJECT NAME: DEPARTMENT: Building Division Public Works 1 7 044+ COOP4 PLAN REVIEW /ROUTINE .$LIP loic inn 2-24-98 0 PALI. Fire Prevention Structural Planning Division Permit Coordinator , DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 2 -26 -98 Complete ❑ Incomplete ❑ Comments: Not Applicable ❑ TUES /THURS ROUTING: Please Route ❑ No further Review Required Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra). REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 3 -12 -98 Approved ❑ Approved with Conditions C Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: \PR•ROUTE.DOC 1/98 ACTIVITY NUMBER: D97 -0388 PROJECT NAME: BOEING #21 -05 DEPARTMENT: Building Division Public Works Complete Comments: Routed by Staff asrumv aursomar PLAN REVIEW /ROUTING SLIP • C DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 2 - 26 - 98 REVIEWERS INITIALS. TUES /THURS ROUTING: Please Route n No further Review Required REVIEWERS INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions El CORRECTION DETERMINATION: \PK•Rou rt.00c 1/98 Fire Prevention Structural a 1 Incomplete Not Applicable El C (if routed by staff, make copy to master file and enter into Sierra) ,a REVIEWERS INITIALS: Planning Division Permit Coordinator Cl DATE: 3/9/60 2 - 24 - 98 DUE DATE: 3 - 12 - 98 Not Approved (attach comments) LI DATE: g/4/16 DUE DATE: Approved LI Approved with Conditions C Not Approved (attach comments) C DATE: • Y.aK >•.cN.M.f IY1L:a4NUri tM•Mm REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F • Psxmi+ cerd. Cory PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0388 DATE 12/11/97 PROJECT NAME BOEING #21 -05 DEPARTMENT: ING DIVISION El FIRE PREVENTION 0 PLANNING DMSION 0 II PERM �0 RI5 LIC WORKS STRUCTURAL '91 IT C 0 , INAT R N . DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE KJ NOT COMPLETE COMMENTS APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: DATE DATE DATE DUE DATE 12/16/97 NOT APPLICABLE Q TUES /THURS ROUTING: PLEASE ROUTE I I NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) I DUE DATE 12/30/97 APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) Q DUE DATE APPROVED [J APPROVED W/ CONDITIONS F-- NOT APPROVED (attach comments) Q (Certification of occupancy requited. 4 � '�i.G^i�N�;�'3�4S71F;tE1 \R Ar COMMENTS • ACTIVITY NUMBER D97 -0388 COMPLETE F REVIEWERS INITIAL 0 . > REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS INITIAL G•: .kill a !.iY R'titlD 'Lt{lQ lwfMiP eWtt)%U % PLAN REVTF,W / ROUTING SLIP PROJECT NAME BOEING #21 -05 DEPARTMENT: BUILDING DIVISION FIRE PREVENTION Cl PLANNING DIVISION 0 PUBLIC WORKS STRUCTURAL El PERMIT COORDINATOR 0 I DETERMINATION OF COMPLETENESS: (T,Th) APPROVALS OR CORRECTIONS: (ten days) APPROVED n NOT COMPLETE [J NOT APPLICABLE El TUES /THURS ROUTING: PLEASE ROUTE U NO FURTHER REVIEW REQUIRED ROUTED BY STAFF (If routed by staff, make copy to master file & enter Siena.) APPROVED W/ CONDITIONS DATE DATE • DATE 1211(0/6 7 DATE 12/11/97 DUE DATE 12/16/97 NOT APPROVED (attach comments) li DUEDATE 12/30/97 • DUE DATE APPROVED n APPROVED W/ CONDITIONS NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) PROJECT NAME BOEING #21 -05 DEPARTMENT: BUILDING DIVISION t-1 PUBLIC WORKS ❑ DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n COMMENTS ' REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED • REVIEWERS INITIAL APPROVED W/ CONDITIONS C:ROUTE -F CORRECTION DETERMINATION: APPROVED ' I l APPROVED WI CONDITIONS ri NOT COMPLETE ❑ FIRE PREVENTION STRUCTURAL El PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0388 DATE 12/11/97 PLANNING DIVISION ❑ PERMIT COORDINATOR ❑ $ 1 DUEDATE 12/16/97 NOT APPLICABLE TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF I I (If routed by staff, make copy to master file & enter Sierra.) DATE L DATE REVIEWERS INITIAL DATE DUEDATE 12/30/97 NOT APPROVED (attach comments) ❑ 2 - A fr - 2 DUE DATE NOT APPROVED (attach comments) ❑ (Certification of occupancy required. ) r�. �!7.yh� }� ry � uc��1+5�.�!�rt t� wxyy . F "wnt:._ 3 h rr q„.v ! � f F' °F <a �y' rXYi�s��i' ish�i" S�z3�a16cKticiltl�E4'`.jd''e..9'- L ei °�.'v � t � AC9l.Sf•4 ' T! � : � ' tvii +x*.ox,r.�l'`d.� 5s'�'1+..;ic. PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D97 -0388 PROJECT NAME BOEING 121 -05 DEPARTMENT: BUILDING DIVISION t_I PUBLIC WORKS 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE ri COMMENTS ' TUES /THURS ROUTING: PLEASE ROUTE [j NO FURTHER REVIEW REQUIRE ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL REVIEWERS INITIAL A FIRE PREVENTION STRUCTURAL El NOT COMPLETE Ej • DATE 12'l0 er3 r APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS NOT NOT APPROVED (attach comments) APPROVED I I APPROVED WI CONDITIONS DATE CORRECTION DETERMINATION: DUE DATE PLANNING DIVISION DUE DATE 12/16/97 NOT APPLICABLE REVIEWERS INITIAL DATE DATE 12/11/97 PERMIT COORDINATOR El DUEDATE 12/30/97 • r NOT APPROVED (attach comments) 0 (Certification of occupancy required. PLAN REVIEW / ROUTING SLID ACTIVITY NUMBER D97 -0388 PROJECT NAME BOEING #21 -05 DEPARTMENT: BUILDING DIVISION El PUBLIC WORKS a J DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE El NOT COMPLETE L! NOT APPLICABLE COMMENTS ' TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF (If routed by staff, make copy to master file & enter Sierra.) REVIEWER5 INITIAL � APPROVALS OR CORRECTIONS: (ten days) APPROVED C] APPROVED W/ CONDITIONS 0. NOT APPROVED (attach comments) 0 REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED n APPROVED W/ CONDITIONS REVIEWERS INITIAL C:ROUTE -F FIRE PREVENTION PLANNING DIVISION ❑ STRUCTURAL El PERMIT COORDINATOR U DATE `2 'IQ 7 DATE DATE DATE 12/11/97 DUEDATE 12/16/97 DUEDATE 12/30/97 DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy requircd. . DATE: DZ.. 20• q i3 PROJECT ADDRESS: 3q/7 CITY OF TUKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 .l bolg7 -00 'x11 It-1 Zl PLAN CHECK/PERMIT NUMBER: ) 97 - 03 PROJECT NAME: BOEING DEFENSE € SPACE GROUP S . loo f / Cpl -os) CONTACT PERSON: GARY TALLER PHONE: 206- 544 -2975 REVISION SUMMARY: i 0101 AL. Si-')P -1C� i 1 Z___ 4t GATE. SHEET NUMBER(S) Z I ' 05 )k 18 12.ex tst oN 'D "Cloud" or highlight all areas of revisions and date revisions. (lyre FEB 2 ' 1998 PERMIT CENTER 41/tA , 4nk 4 e €4 . SUBMITTED TO: City of Tukwvila Fire Department l� 17 Fire Department Review Control #.06/7-10.3; Re: Fence at &eit29 47 6/7 - 0 5 3 5 c at) P/ Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Maintain fire extinguisher coverage throughout. 2. If the fenced -in area is to be occuppied on a regular basis, the following exiting requirements shall apply. Gates and barriers shall be openable without the use of a key or any special knowledge or effort. Gates and barriers in an exit Shall not be locked, chained, bolted, barred, latched or otherwise rendered unopenable at times when the building or area served by the exit is occupied. (UFC 1208.2) Gates and barriers installed across an exit shall be of sufficient size as to be capable of opening so that the clear width of the opening is not less than the exit width required by the Building Code. (UFC 1208.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S75•4404 • Fax (206) 5754439 . ..� . Page number City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fine Chief material or matter where its presence would obstruct . or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and . marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1- 1212.8) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) ' Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, lCJ.YCG4:at..+� The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 37.5-4439 I VICINITY MAP AREA MAP GENERAL NOTES DRAWING INDEX \ KING COUNTY FROM DOWNTOWN SEATTLE ❑ AIRPORT OFFICE I 14 -01J A CENTER (FAA) BUILDING 21 -05 3417 SOUTH 120TH PLACE TUKWILLA, WASHINGTON (EAST MARGINAL WAY CORPORATE PARK) - IONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. '. VERIFY ALL DIMENSIONS PRIOR TO START OF CONSTRUCTION. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRED DESIGN REVISIONS. U. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BUILDING 9 -51.2 COL. N /1, AFTER COMPLETION OF THIS CONSTRUCTION. SH DI NO. NG SHEET TITLE REVISION DATE Al 21 -05 -A1 TALE SHEET A A R A A 12.10.97 12.10.97 12.10.97 12.10.97 12.10.97 1AO1 21- 05 -1A01 FIRST FLOOR ENING PLAN 1A15R 21- 05 -1A15R FLOOR ELAN - REMOVAL 1A15 21-05- 1A15 FLOOR PLAN 1AI8 21- 05 -IA18 FLOOR PLAN it 900 ° Tz 9' � N TA L.1 -N N ] s A� �_a s� i v � i / 99 ; , -. E MT \ 15K 158 I, OX BOW LOT "% • A OEIN! ACCESS RD J` J ' p � Q N txir 21 -02 21 -01 PROJECT CHECKLIST CODE SUMMARY \ PROJECT SITE CHECK BOX ® THESE DRAWINGS CONFORM TO THE 1994 U . B . C ., U.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ® ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS 2. TENANT IMPROVEMENT (NON- STRUCTURAL): 21 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. ❑ 4. MECHANICAL, 4 COMPLETE SETS. ❑ 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: REMOVE APPROXIMATELY 70 L.F. OF SHOP FENCE, DOOR AND CHICKEN WIRE ROOF. REMOVE APPROXIMATELY 18 UNITS OF METAL SHELVING. INSTALL APPROXIMATELY 120 L.F. OF SHOP FENCE, DOOR AND GATE. LAND USE CODE M HP CITY OF TUKWILA ( ) CODE REFERENCES 1994 U.B.C., U.F.C. , U.P.C. , AND THE WAC51 -20 AS ADAPTED OP, AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. OCCUPAN.,( GROUP B (OFFICE), F -i (FACTORY) - NO CHANGE OCCUPANCY FLOOR AREA (ACTUAL) 200,446 SF BUILDING FOOTPRINT STORIES 1 FIRE PRO''ECTIONS FULLY AUTOMATIC, WET PIPE THROUGHOUT SEISMIC ZONE 3 FIRE ZONE 3 PARKING ''ROVIGED 739 PARKING :EgUIRED 725 NOTE: ME: AND ELECTRICAL PERMITS ARE TO BE SUBMITTED SEPARATLY FROM THIS PACKAGE. — -- I 2 _ I ll -03 I CD � 1 \ L N , I I I 1 ] I I� \ li \ I I 21 —O'J 5 Q l /j /'r // '/ rr" ' s7— -- S - ,, 599 EAST MARGINAL WAY TUKWILA CORPORATE PARK 99 \ FROM KENT & AUBURN . s7 \ 00 5 ! I J I ` `' I I I I I \ - II ' �' O \\ No SCALE EAST MARGINAL WAY CORPORATE PARK _ FILE �� {understand that the Plan Check aFFr. are C e and approval of I u nde to errors end omissions puns does not meads *{9 M do. of any ad'pted cods a d 1 of ' copy of appoMrd pre =i� /i By Ar to FROM SEATTLE AIRPORT PROJECT SITE N i ®u V NO SCALE DEVELOPMENTAL CENTER [1:91 8 1•®33 Date i g i'S' Permit 1.711 ; . D SAM A R LD'LATE MUD US STORAGE pnrcrim_. REVISION APPROVED '1 4160197 -00 av GMM u - En [NI] [ REVISION 9 SPACE AND DEFEN - BULDIING 21-05 REOCATE MSD MU STORAGE (J160197-00) BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 APPROVED DATE p rZFAE,Afig° ACCEPTABILITY THIS DES:GN AND /OR SPECIFICATION. IS APPROVED APPROVED BY DEPT: DATE DRAWN M. DITTMAR CHECKED ENGINEER T. HANSON CHECKED APPROVED APPROVED DATE SUBTITLE 12.01.97 12.01.97 TITLE L SMInF S TITLE SHEET BUILDING 21 -05 URR,NT REVISION 160197 -00 SHEET JOB NO Al SYMBOL A ARCHITECTURAL MASTER COL CORP. PARK 0 O. 21 -05 -A1 COMP N0. 12.10.97 st SYM I REVISION A RELOCATE MSD IDS STORAGE c w2 j160197-00 5 21 -03 BLDG. (1181) (1281) v�L FLOOR PLAN SCALE: 1 "= 30' -0" ( E2 E3 BY GMM APPROVED DATE 12.10.97 SYM REVISION APPROVED DATE p orwiva. ( 05 > (N6) APPROVED BY ( EB K 56 ACCEPTABILITY THIS .. DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE bRAWN M. DITTMAR CHECKED NON R T. HANSON CHECKED APPROVED APPROVED 3) PROJECT AREA 6 DATE 11.19.97 1 2.01.97 SUBTITLE TITLE ARCHITECTURAL MASTER COL. A -G/1 -9 FIRST FLOOR EXITING PLAN BUILDING 21 -05.1 LEGEND: I :7 EXIT PATH GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORD AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. CONSTRUCTION NOTES: 1AI10 1A11 1A13 1A16 1A19 A14 I 1A15 1A17 1A16 1A20 1A21 KEY PLAN 0 s:aiF: NUKE' L— SYM R RELOCATE SD US STORAGE 0 FE DTio se BY GMM REVISION J #160197 - 00 APPKWED DATE 12.10.97 SYM REVISION E m PLAN SCALE: 1/8" 1' -0" APPROVED DATE p ritzttErAw. 78' 1 /2" ACCEPTABILITY DRAWN M. DITTMAR THIS DESIGN AND /OR CHECKED SPECIFICATION IS APPROVED APPROVED BY DEPT.. DATE ENGINEER T. HANSON CHECKED APPROVED APPROVED DATE, 10.18.97 11.19.97 SUBTITLE TITLE FLOOR PLAN - REMOVAL BUILDING 21 -05.1 ARCHITECTURAL MASTER COL. E -G/3 -5 CORP. PARK LEGEND: r'✓ FA�` FE u FP GENERAL NOTES: DWG N0. STEEL STUD PARTITION DEMOUNTAEL E EARTITIOI,S '7' -0' HIGH) METAL =ACED PARTITION FIRE ALARM T STROBE FIRE EXSTINGUISHER FIRE EXS1INGUISHER 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HA':/ BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF A`3ESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO 3E REMOVED TO SUPPORT WORK. CONSTRUCTION NO - I ES: L. REMOVE EXISTING SHOP FENCE COMPLETE (APPROXIMATELY 70 LF.). SAVE FOR REUSE. REMOVE EXISTING UNISTRUT AND CHICKEN WIRE_ ROOF COMPLETE SEND UNISTRUT TO STORES. REMOVE EXISTING SHOP FENCE DOOR AND HARDWARE COMPLETE. SAVE FOR REUSE. .. REMOVE EIGHT (8) EXISTING 36 "W x 36 "D METAL SHELVING UNITS COMPLETE. SAVE TO AGING. REMOVE TEN (10) EXISTING 36 "W x 18 "D METAL SHELVING UNITS COMPLETE. SAVE TO AGING. 1A10R TAT 1R' 1A13R 1AIRR 1A16R 1A17R IA18R 1A19 1A20R ;AO1R CURRENT REVISION 'SYIA80L 160197 -00 KEY PLAN r) SCALE MN! e9 SHEET 1 A 1 5 R JOB NO. J,'P N0. 21-05-1A1 SR 12.10.97 A RELOCATE MSD IUS STORAGE 91-7 ! SYM REVSION se 4160197 - 00 BY GMM APPROVED DATE 12.10.97 SY REVISION BV APPROVED 78' -1 1/2" p 7,6FEZAW® D N6 ACCEPTABILITY RAG DESIGN AND / OR SPECIRCAGAN IS APPROVED APPROVED BY DEPT. DATE 'DAWN M. DIOMAR CHECKED ENGINE. T. HANSON CHECKED 10.18.97 11.19.97 SUBTITLE DTLE FLOOR PLAN BUILDING 21 -05.1 i ARCHITECTURAL MASTER COL. E —G/3 -5 CORP. PARK LEGEND: STEEL STUD 'AR T ITI ,N DEMOUNTABLE PARTITIONS " —O I,'iCH) METAL FACED PARVION F FIRE ALARM et STROBE FE ° FIRE EXSTINGUISHER U FIRE EXSTIIJGUISHER FP GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA ITS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF TOS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. CONSTRUCTION NOTES: INSTALL APPROXIMATELY 86' -0" L.F. OF 8' -0" HIGH SHOP FENCE COMPLETE (TOTAL THIS SHEET). USE NEW AND REUSE MATERIAL FROM REMOVAL. SHOP FENCE PANEL (l' -10 "L x 8' -0 "H). TYPICAL OF TWO (2). SHOP FENCE PANEL (3' -0 "L x 8' -0'H). SHOP FENCE PANEL (2' -8 "L x 8' -0' H). ATTACH TO EXISTING COLUMN FURRING IN LIEU OF A SHOP FENCE POST. - INSTALL 3' -0 "W x 8' -0 'H SHOP FENCE BOOR AND HARDWARE COMPLETE INCLUDING SPRING HINGES AND UNICAN. USE MATERIAL FROM REMOVAL. © FABRICATE /INSTALL 8' -0 "H x 15' -0"W ROLLING GATE (NO OVERHEAD TRACKS) COMPLETE. ALL REQUIRED COMPONENTS (BOTTOM TRACKS, GLIDES, SUPPORTS, SHOP FENCE PANELS, HANDLES, WHEELS, HASP AND PADLOCK) ARE ON SITE STOCK) (SERVICE TEAM CONTACT CHRIS JONES (47 -3863) FOR ON SITE). LOCATION OF COMPONENTS. LAG ALL SHOP FENCE CORNER POSTS, GATE AND DOOR POSTS TO FLOOR WITH 4) 1/2" DIAMETER x 3 3/4" LONG ANCHOR BOLTS (3" MINIMUM EMBEDMENT). LAG ALL OTHER SHOP FENCE POSTS TO FLOOR WITH 2) 1/2" DIAMETER x 3 3/4" LONG ANCHOR BOLTS (3" MINIMUM EMBEDMENT). PAINT ALL SHOP FENCE, GATE AND DOOR COMPLETE. MATCH EXISTING. INSTALL FIRE EXTINGUISHER AND HARDWARE COMPLETE MOUNT TO SHOP FENCE POST. 1/110 1A11 1013 1014 L _ .. . ...... 1015', 1/116 IA'7 1018 1 /119 1A�0 1071 CURRENT REVISION SYMBOL 160197 -00 A SHEET 1A15 KEY PLAN N SCALE NiSNE J09 NO. _ COMP NO. DWG NO. 21 -05 —!015 / DATE 12.10.97 A FLOOR :'ACE /P'ELD SHOP 11_13 ST,1111AGI: RELc..,... SOP 111S S OP:POE J. BURKS' r.M OMM GMM APPROVED t uJ 4 TE 12.10.97 12.20.97 02.20.98 SYM ENSIGN _o_y 160084 4100197 -00 J#160197 -00 JO STC 2 <.G!- {REVISION 11) J1160197 -00 REVISION ' APPROVED BUILDING 21 -05.1 COL E G/5 -7 LEGEND: STEEL STUD PARTITION DEMOUNTABLE PARTITIONS (7' -0" HIGH) METAL FACED PARTITION FA FIRE ALARM & STROBE FE O FIRE EXSTINGUISHER U FIRE EXSTINGUISHER FP GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED • AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. CONSTRUCTION NOTES: INSTALL APPROXIMATELY 90' -0" L.F. OF 8' -0" HIGH SHOP FENCE COMPLETE (TOTAL THIS SHEET). ALIGN SHOP FENCE WITH CENTERLINE OF EXISTING SHOP FENCE AND APPROXIMATELY 9" SOUTH OF EXISTING TRENCH. SHOP FENCE PANEL (4' -0 "L x 8' -0" H). ATTACH TO EXISTING COLUMN FURRING IN LIEU OF A SHOP FENCE POST. TYPICAL OF TWO (2). SHOP' FENCE PANEL (2' -3 "L x 8' =0 "H). SHOP FENCE PANEL (2' -O "L x 8' -0 "H). SHOP FENCE PANEL (2' -81 x 8' -0 H). SHOP FENCE PANEL (1' -3 L x 8' -0 'H). /INSTALL 8' -0 "W x 8' -0 "H ROLLING GATE (NO OVERHEAD TRACKS) COMPLETE INCLUDING TRACKS, GLIDES, SUPPORTS, SHOP FENCE PANELS, HANDLES, WHEELS, HASP AND PADLOCK. V INSTALL 3' -0 "'WW x o' -0 H SHOP FENCE DOOR AND HARDWARE COMPLETE INCLUDING SPRING HINGES AND UNICAN. 9. LAG ALL SHOP FENCE CORNER POSTS, GATE AND DOOR POSTS TO FLOOR WITH � 4) 1/2" DIAMETER x 3 3 4" LONG ANCHOR BOLTS 3 " MINIMUM 'EMBEDMENT LAG ALL OTHER SHOP FENCE POSTS TO FLOOR WITH 2) 1/2" DIAMETER x 3 3/4" LONG ANCHOR BOLTS (3 MINIMUM EMBEDMENT). 10. PAINT ALL SHOP FENCE COMPLETE. MATCH EXISTING. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 1 DATE DA DRAWN M. DITTMAR CHECKED ENGINEER T. HANSON 11.19.97' 11.19.97.'.. I - ' t..:: tha Plan Ch to ETT T and omissions anJ p,_.., cols not autllorits tiIS VIOIahon code or eidAIMMI NSONpt of contTactcr's CDT7 ET app ,.ved • - Permit No. FILE COPY KEY' PLAN ,SEA LE NONE I CORP. PARK CITY OF TUKWILA APPROVED MAR 0 IV 1w0' AS r,,LL, I CURRENT REVISION 160197 -00 SHEET 1A18 JOB NO. DWG N0. SYMBOL 21- 05 -1 A18 DATE 02.20,98 .i� COMP NO. 4Ii-n