Loading...
HomeMy WebLinkAboutOrd 0730 - Fire Alarm Systems in Buildings (Repealed by Ord 1141) ov Jplq ,61) 1 idt w`7% s 4 /006 CITY OF TUKW WASHINGTON ORDINANCE NO. 730 RE EM E B \L AN ORDINANCE ESTABLISHING MINIMUM REQUIREMENTS FOR FIRE PROTECTION SYSTEMS IN BUILDINGS WITHIN THE CITY OF TUKWILA USED FOR ASSEMBLY, EDUCA- TIONAL, INDUSTRIAL, INSTITUTIONAL, MERCANTILE, STORAGE,.. AND MULTI FAMILY DWELLING PURPOSES THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, DO ORDAIN AS FOLLOWS: Buildings within the City of Tukwila used for assembly, educational, industrial, institutional, mercantile, storage, and multi family dwelling purposes shall be equipped with fire protection systems which meet the following minimum requirements: A. Sprinkler Systems Required: A fully automatic sprinkler system designed, installed and tested per NFPA #13 (Current Edition) shall be installed in all new buildings in excess of 20,000 square feet total floor area. B. A fully automatic sprinkler system per (A) above may be required by the Chief of the Fire Department and the Officer in charge of the Fire Prevention Bureau for new buildings under 20,000 square feet total floor area when, in their judgment, any of the following conditions exist: Hazardous operations, hazardous contents, critical exposure problems, limited accessibility to the building, or other items which may contribute to definite fire hazards. C. Hose Stations Required: Hose stations (standpipes) shall be required in all new buildings. t- -1- 1. Hose shall be U.L. approved 1 1/2" diameter rubber lined fire hose, 75 feet in length with an adjustable (fog -type) plastic shut -off type nozzle. (Nozzle type shall be approved in writing by the Tukwila Fire Department Fire Prevention Bureau.) 2. Design, installation and testing of hose stations shall comply with NFPA #14 (Current Edition) with any exceptions stated herein. 3. Hose stations shall be "wet." That is, water pressure shall be present at the individual station valves at all times. 4. All hose fittings shall be National Standard Thread, Higbee -Cut. D. Where this Ordinance conflicts with the Uniform Building Code requirements (Adopted by Ordinance No. 678), the more stringent (greatest protection) shall apply. E. Any exceptions to items covered by this Ordinance shall be made by the Chief of the Fire Department and the Officer in charge of the Fire Prevention Bureau. Such exceptions must be in writing. F. Existing Buildings: 1. Existing fully sprinklered buildings when remodeled or added- on -to, shall retain the feature of being sprinklered in the remodeled or added -on portion. 2. If by adding -on to an existing building, the resulting total structure falls within the cover- age of (A) or (B) of this Ordinance, the entire structure shall be fully sprinklered. -2- -rT Passed by the City Council of the City of Tukwila and approved by the Mayor at a regular meeting thereof on the jg tiv day of September, 1972. Maylor Attes City lerk Approved as to Form: City Attorney Published: -3-