Loading...
HomeMy WebLinkAboutPermit D98-0047 - BOEING #11-14 - OFFICESBoeing #11-14 Contractor OCCUPANT OWNER CONTRACTOR Signature:_ Print Name:__ City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 092304 -9155 Address: 11201 PACIFIC HY S Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: AOFF DEVPERM MIC /H KR314E SEC923 001 North: SEATTLE South: Sewer: VAL : "Vi1 Slopes:: .'N License .No: .:BOEINC *294MC DEVELOPMENT PERMIT BOEING` #11 -14 11201`.FACIFIC HY .BOEING 'H &`M. ASSOC,. POB 3707 M/S IF. -09, SEATTLE WA 981214, BOEING COMPANY P O., ,,'BOX 3707, M /5. :.IF -09, SEATTLE, WA 98124 S, TUKWILA Permit Center Authorized Signature: WA Occupancy: UBC: Fire Protection: East: .0 West: 98188 CONTACT RICK : FORD P.hone 2 06 :-6.55 -9888 :P0 BOX. 3707 M/S 1:9 -35, SEATTLE WA 98124 ;.,"' r** * * * * * * * * * *; * * * * * * ** k * * * * * * * * *.* eft * *�Y, ** ** SAC************* * * * * ** * * * * * * * * ,t * * * * * * * * * * * * ** Permit Description: ADDITION. OF 6 OFFICES r********************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 50,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant:. -'N Flood Control Zone: N Hauling: N Start Time Land Altering: N Landscape Irrigation: N Movirig'•Oversized Load: N Start Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Storm Drainage: N Street Use: N Water Main Extension: N ,Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** TOTAL DEVELOPMENT PERMIT FEES: $ 952.84 ********** * * * * * * * * * * * * * * * * * * * * * * * * * * ** **********.(** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ?L4 qe..4) J 2 i- 1 4ip This permit shall become null and void if the work 180 days from the date of issuance, or if the work for a period of 180 days from the last inspection. Permit No: Status: Issued: Expires: Streams: Listed Separate) Eng, Size(in): End Time: Fill: The granting of this permit cancel the provision of any or the performance of work. development permit. G4!e. Date: (206) 431-3670 D98 -0047 ISSUED 03/04/1998 08/31/1998 OFFICE 1994 SPRINKLERS /AFA .0 N -5-9g Date :`7 — I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. does not presume to give authority to violate or other state or local laws regulating construction I am authorized to sign for and obtain this is not commenced within is suspended or abandoned •Address 1 120 PACIFIC H Y ;,', Fermi t .No: D98 -0047 Suit Tenant Status ISSUED,..::', Type DEVPE App :`02/17!1998. Parse;! ; # 0 9155 Iss.iied 03/04 1998 **.*. kk` kA,* k* k* Ak k• k, kkk*' k'• Ai k**'* k, Y * A • k• k vk *•A A *,** kk4` kAk*: Akrt•* k' k •k`k lc *•Ak ` A •kkw'k•k,k A *A'k.*4 Permit Conditiornc 1 No changes will ; be made , the pl ans unless appr by th Architect or Engineer :and tl eT,.u.k-wi .a Btiildi9g Divi a. i El tate Di on is ectr•'ical : permi ts ah 1�1 7,p tei G uah 'the Washi ngton Svi of � b§.1 'rrd rndustri'e"*4 ai � „1,� electr '1..4 1 w ork wi 11 b:e in,; �c.ted b, itiia ag ii:cy (24 -, :,• �be , t e : ,i . A1: mechart-ic ,.j d ,'�`l c t ner atrir , .ue d by , a . . +y�s� a �r . 1 � d y Q y s.ep r� era y , the . City tot i.�tt,:3•w. 1 K�1 .� r: j . 35,...p 2t .� ,' * fir ''.7: `t TAll prmit' � i;oniirecord, .an`. appr o ed v .p a e Tha11 be.' ± . v Y {� .. � � s `s �?,+ � `� S d . 3,, far r , ttip� aa ila,bl at th:e Jot.' sit pr:,ior .to,the2 star of an, c str.uct`i w Tlie?e 'oc nie : a yto b`e ma "i'ntained fa d ava� l - ak►:le .0 .31 in.spec 1s•: rant An- rie , n t2l f , u tf ti y t r4 I) ing. g ,'i`d a (7 h t f ' i )5,�ure .i 6 ''ha tio is , ,, re,qu r ; o meet '' �l ate , r � al, \ br`t a cing' # req u ir mie ns: turn: Seismic\ • Par t oti'' w:alls_: at;tached to ei e l rig :7 gr id. must be klA4.' 9l v, \T brae d' 3t o.fver :ei ght'rt8) feet in length e w ter ,ate ` r A1 ons tr ct ion t ` °d one '?i f't n' copft o,r "m artc,e w ith app ov'e t s a pl�n "': ; e .Ii're o en t w he U i, - 0 m 1BuiXi '. ding Lad (1 99 4 t d a.' 1 d r �}t t .. M e c` r' n i l . i ' I .. � E1 0 6i.,0, t a . a�ireiidet. . Up a iyani 1 1 C .) 6.;(1994 - Edit,. 66,'Y. a AI, ash i . n tat`e g tdn . EnergY'.`Code :,(,19.94 "Ed�i t toil ' � i A .- H '` �, 5 � � � t 1 .� �� - U 1 i t ..f, Permit ;- ,M'The l 5s � W,. permit or a r oira i a t' pla speciticati and � com uta ptjon.s,:.us•hall nob ' con. -. trued G to be a p ermit •tor, or `tl�':;appr` o va °l ot zany, vio k•„ of . �a n of, th e pr ovi s l ons at they bui,l d i ng. °`code, or of any a. ; . ./i. T ' a r d i f tQ e: of 'the ,j 4risdict:ion�., Np m p esumg, :o . in tr give,, A'iith„ori,ty to violate Or ca nce th o - ovision o ;this t code. ( va"{ 1 t'.' i ti ° '' St tr, • VEtNTI A�T,ION IS REQUIRED :FOR ALL 'NEW,, OO AN } ,.SPACE:S. :OF NEWS XI' OR' E �T t N G B UILDIN'G'. IN : CONFORMANCE `WITH THE UN ,F ,. �f ORM ` BUILDING�'CODE AND ,THE .WASHINGTON ti TATE VENTILATION ' AND /1 ... INDOOR` AIR' QUALITYY CODE ," ' 51 1, ' .) 414 '''' Project Name/Tenant: L)1.11110n Iti/ .8Asi 7LL — 61.04 // - 14 Value of Construction: S D`QDb G Site Address: /12 D/ 1 /Fie #64 --$:, City State /Zip: 73/Awri..0 Tax Parcel Number: 0'1 Z3c4 — q.155 Property Owner: Building Square Feet: REV 061 existing Area of Construction: (sq. ft.) 4, DD Phone: Street Address: # RD. 6‘• 37D7 19 ._35 S'4 r7 a/o City State /Zip: ' B� 24 Fax #: Contractor: / Phone: Street Address: City State /Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: Lk- Doi) Phone: ?Ou , 6 s- — 1$0 Street Address: SA.14 rE n S AA D d • City State /Zip: Fax #: 74,4 54•4 - Z. Z7 Description of work to be done: / ISO G pFFte 63 Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel pq Office ❑ School/College/University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse CI Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel .l Office ❑ SchooVCollege /University ❑ Other Will there be a change of use? ❑ yes JJ no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 0 no Existing fire protection features: 41 sprinklers V automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: REV 061 existing Area of Construction: (sq. ft.) 4, DD Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUK_ YILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT; REQU EST' FOR PUB LIC.WORICS SIrgtoVIL PLAN;F)EVIEW OF THE F.OLLO (Additional reviews may be determined :by:the Pulillc:Works'Depertment)= ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk Cl Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous CTPERMIT.DOC 1/29/97 ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: tltrilb Date application expires: r1. l Appllcati on by: (initials) PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWN R OR AUTHORIZED AGENT: Signature: / .Irr - " ' . ,k, Phone: 204 Date: ...-..-- 1 7 -c2 , rga ? :.. 'Pd ##2I'4 1' -2027 Print name: of , � ,r Address , ` ' / �' � 1 , City /State /Zip ALL COMMERCIALJMULTI-FABLY TENANT IMPROVEMENT /AL 'ATION PERMIT APPLICATIONS MUg BE SUBMITTED WITH THE FOLL i WING: D. V. RAW �T,EIBE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, '4 R ' �1 T�IVG 'IEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification If there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Cl Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names'of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site El ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished El ❑ Construction details ❑ El Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. El El Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. El ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ El Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296-4787. (Form H -5) El ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 This l PACIFIC S Total FeoS: 952.81 352.8 Tat ` AL:L.Ptnts . Dal amts - ::' . .. 00 . . k11 *4*ofdkA *.'k* kk*'*• A***4* zti *o**it4,A•k•A;kko .k�eA *. *lootkktoLh5l'F�l . *. +F.4 ofkA.kkklf. #khi A4 Y +� `� k�l f lt � hh�t.*$ i *'kf t**/*'n'.*`V* /r OTT V OF 1 !4!A %, 1,RCANSMT ai i*'A•k* 1 *k',t'*k* *'.� k *til hAkA *.'k*:A *•a *of *•k * *-k* *k;t•kktk 1k•**.a*A * *:k-A*A' *.1 k•A•A' *:A` ..1IU NS MIT: Number: 8 15.::Amauni »..' 952 8 62/17/98 `10 ::15 y Pament ;liethod:: TRUST •Notat.io n: :BO ING Cni't: Bt.M * k,k * * ** *•k. *•. *.. &. A • k *i1 :A *. Accoun' C)esLPip�tiOn s` 000/.322'. DING. NCtNRE5 000/345.830: PLAN CH C 1( '- MONIES O00 /. :8E,.n04" STATE BUILDING £URCHARGE Permit Not . 1)98-0047. .. :. Type: DEVPEIUM DE.VELOPi EW'f ::PER ttIT,;. Parcel No: 092304 Si te: Address: 11201 INSp RECORD Retain a copy"wit permit INSPECTION NO '? CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., Cod, iukwila;-W(9t Project: Address: 1/Qt? Special instructions Type of inspec Date. calDed: Date wanted: Requester: '2Gj3e' Phone No.: 5Lft4-338P COMMENTS: Inspector: Date: 11-L2--96 .Approved per applicable codes. Receipt No.: Cl �i7 PER�AIT NO, ~ 431 -3670 Corrections required prior to approval. $42,00 REINSPECTION I4E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, CaII to schedule reinspection. Date: INSPECTION. RECORD: Retain a‘copywith permit INS • N•:.::. PERMIT NO C ITY OF TUKWILA'BUILDING: DIVISION 6300. Southcenter .Blvd #100, Tukwila, :.WA 98188 Project: : Phone No.: COWIMENTS :. Inspecto Date: Approved per applicable codes. j;. Corrections required prior to approval. (206). 431- 3670 $42 0 REINSPECTIO !FEE RE • UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Proje • Type of tio - it' Date called: Add a s: Special instructions: c Date wanted: G � q � 1 • /� a.m. p.m Requester: !3C�1 Phone No. �0jo s • / INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd:, #100, Tukwila, WA 98188 Approved per'applicable codes. (206) 431-3670 Corrections required prior to approval. COMMENTS: $42. ' EINSPECTI N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cal to schedule reinspection. I Receipt No.: Date: �__. •••∎ INSPECTION RECORD L , Retain a copy with permit E INSP ON NO CITY OF TUKWILA,BUILDING DIVISION 1 6300: Southcenter Bivd., #100, Tukwila, WA 98188 IN COMMENTS: Project: Type of inspections �''�`����� Address: Date called: IZD �'�l� Special instructions: Date wanted: a.m Requester: fJ�rJ Phone No:: � Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Receipt No.: w.Y.'..Wumu._,.m.9cr Nan '-'ia: - 'IFtl.,...4,r,...Cti . x. �...,.,,x.+a...s.....k _... h, Date: 17(S'---/ INSPECTION RECORD L , Retain a copy with permit E INSP ON NO CITY OF TUKWILA,BUILDING DIVISION 1 6300: Southcenter Bivd., #100, Tukwila, WA 98188 IN COMMENTS: Project: Type of inspections �''�`����� Address: Date called: IZD �'�l� Special instructions: Date wanted: a.m Requester: fJ�rJ Phone No:: � Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Receipt No.: w.Y.'..Wumu._,.m.9cr Nan '-'ia: - 'IFtl.,...4,r,...Cti . x. �...,.,,x.+a...s.....k _... h, Date: • City of Tukwila John W Rants, Mayor Department of Community Development Steve Lancaster; Director January 4, 2000 Rick Ford PO Box 3707 MIS 19-35 Seattle, WA 98124 Sincerely, Bill Rambo Permit Technician Xc: Permit File No. D98-0047 Duane Griffin, Building Official • Permit Status D98-0047 11201 Pacific Hwy S Dear Mr. Ford In reviewing our current permit files, it appears that your permit for a tenant improvement issued on March 4, 1998, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniforin Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized bysuch permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non-complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431-3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Alnn .SrmthrantPr Rtv1Pvarrl. Suite #100 • Tukwila. Washington 01;188 • (206) 414670 .9 Fax: (206) 431-3665 ACTIVITY NUMBER PROJECT NAME PARTMENT: ING DIVISION El ast 0 • � DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 2 -19 -98 COMPLETE NOT COMPLETE E NOT APPLICABLE 0 COMMENTS TUES /THURS ROUTING: PLEASE ROUTE Ej NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF [J (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED El REVIEWERS INITIAL C:ROUTE -F ?ertnt Cook PLAN REVIEW / ROUTIN D98 -0047 BOEING BLDG 111 -14 sttraw ' DATE DATE 2 -17 -98 6 0 P��G D ��ON PERMIT 'COORDINATOR DUE DATE 3 -5 -98 APPROVED fl APPROVED W/ CONDITIONS ❑. NOT APPROVED (attach comments) Q DATE DUE DATE APPROVED W/ CONDITIONS n NOT APPROVED (attach comments) 0 DATE (Certilcadoa of occupancy required. ) Dear Sir: City of Tukwila Fire Department Fire Department Review Control #D98 -0047 (510 1. The total number your establishment is each 3000 sq. ft. of of the "All Purpose" distance to any fire (NFPA 10, 3 -1.1) February 23, 1998 Re: Boeing Company Building #11 -14 - 2925 South 112th Street The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: of fire extinguishers required for calculated at one extinguisher for area. The extinguisher(s) should be (2A, 10B:C) dry chemical type. Travel extinguisher must be 75' or less. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444Andover Park East • Tukwila, Washington 98188 • Phone (206) 5754404 • Fax (206) 5754439 City of 71tkwtla Page number Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that. indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall be openabie from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exii doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) Current supply to one of the lamps for exit signs shall be provided by the premises' wiring system. Power to the other lamp shall be from storage batteries or an on -site generator set and the system shall be installed in accordance with the Electrical John W. Rants, Mayor Fire Department Thomas P. Keefe, Flee Chief Headquarters Station: 444 Andover Park Bast • Tukwila, Washington 98188 • Plan (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 Code. (UBC 1013.4) 3. Any room having an occupant load of more than 50 where fixed seats are not installed, and which is used for classroom, assembly or similar purpose, shall have the capacity of the room posted in a conspicuous place on an approved sign near the main exit from the room. Such sign shall be maintained legible by the owner or the owner's authorized agent and shall indicate the number of occupants permitted for each room use. (UFC 2501.16.1) 4. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk .Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 5. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. All new fire alarm systems or modifications to ' existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 6. The fire protection drawings in the building permit packet need to be submitted to the fire department for John W. Rants, Mayor Thomas P. Keefe, R,e Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone' (206) 5754404 • Fax (206) ,575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Rre Chief permit and approval. 7. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 8. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 9. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) 10. Commerical dumpsters and containers with an individual capacity of 1.5 cubic yards or greater shall not be stored or placed within 5 feet of combustible walls, openings or combustible roof eave lines. (UFC 1103.2.2) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 57$4404 • Fax (206) 575•4439 Headquatters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 57.4439 ' (360) 90243216 FAX (360) 902424 Olympia thadquancia .......... . �h. iL w £i0, _._.. , .�w.:.wr1MN.....N:M..W11 • ..e.�...1. .1 w ..r�..wr�.MM...�w11M1 .. 1 BOEING CClttiPANT THE ... ..�.+ MI rN...+�.� +..�MIN� . nwMN... M1 IIM.�.NI..�...j. � ..+•w+...wIIIMIN +.. ' e$nat >num •t,a st oa.*1w t L HAEIM 0 294?Q. 1 -1 -99 ) Contractor: Your Certificate of Registration will be sent from the Olympia office and should be received within 2 to 3 weeks. Please keep this record until you receive your Certificate of Registration. F625+036-000 osigueim verification 2.95 �. RECEIVED CITY. OF TUKWILA FE B 1 7 1998 PERMIT CENTER S Y M . A DUWAMISH 8ACKFILL E 1 S I 0 N 4979167 1/29/98 1 1- • : SITE PLAN SCALE: NTS — 1 H (1___AliziozrAtovat USE OF BUILDING: OFFICL Wahl .',..E.,E.E..uRY PAREMEIG .-- ---, , I I CoCC FLOOR P PARKENG B 2 l ut i 8-1 PARNING !GRO O S' I 11 _ , ,E ANLA 45,5/2 SF PARKIEIG SEALL S REQUIRED: PARKING SEALE S PROVIDED: 1,573 STALLS 313,300 SF. 1 260 = 1,57 STALLS I S H ,E D C R O D TED 33826'2.::7C81' SF 58 COMPCT F 9 STANDARD 9 A 18 HANDICAP FI FO FT UR H TH 34,E72 SF 4 LOAD 3' SF • NET SQUARE FOOTAGE [ACE UDES CORES, CORRIDORS ,NG . BUILDING LOBBY, AND SEi L AREAS. LEGEND 8.. Ss. . mats. SiSa SZAJ. QUIP Clapar.. SAL —4.11.-Supsweit LEGAL DESCRIP THAT PORTION OF GOVERNMENT LL SECTION 9. TOWN11-! 23 NOR iTi, RRULE 4 [ASI, .M NEG COON ry, WAS} ENG TON, DESCR.BE .1) AS t LIL OWS: BEGiiiniNG AT pHE INTERSECTION ENE NORTH LINE Or SAO GOVERNMLNI LOT 2 AND Di WESTERLY MARGIN OF STATE ROAD NO. 1; AND RUNNIT.., THENCE ALONG !.AiD EASTERLY MARGIN OF STATE ROAD N0.1. S 18d5720W. 972.08 FEET, MORE OR LESS, 1 NEE NORTH BAIA. OF THE DUWAMISH RIVER; THENCE WESTERLY, NORTHWESTERLY, AND NORTHLY ALONG SAID BANK OF .HE DuWAMISH RIVER TO ITS INTERSECTION WITH THE NORT i LINE OF SAID GCNERNMENT LOT 2; THENCE I! 85,I305CrE ALONG THE NORTH LINE OF SAID GOVERNMENT LOT 2, 845 FEET, MORE OR LESS, 10 THE TRUE POINT LEK BEGINNING. SITE NAME. l■LEWAMISH OF Fitt_ 11201 PACIFIC FE.,;:f4AY Soul STE AREA: 12.92 ACRES ZCENENG. LIH (HEAVY MANU F uVEING) SEISMIC ZONE 3 FERE ZONE 1 Ens,_ 7297 TOTAL X 2 BLOGS, 376, I d SF ARCHITECTURAL MASTER. COL. GENEkAI. NOTES PROJECT AREk APPROX. 800u S.F. PROJECT DESCRIPTION: TENANT IMPROVEMENTS - DEMOLITION, WALLS, DOORS, LIGHTS, HVAC,SPRINKLERS MID OFFICE FURNITURE OWNEH: BOEING COMMERCIAL AIRPLANE GROUP WEST REGION FACILITIES P. 0. BOX 3707, 1,4/S 19-35 SEATTLE, WA. 98124 - 2207 ATTENTION: RICK FORD (206) 544-1644 COVER SHE DUWAIvIISH OFFICE PARK BUILDING 11-14 DLIOa247 ET DUWAMISHI SHEET JOE NO_ D'AG NO. TUKWILA 0 PLUMEiNG 0 GAS PIPING ripf Of ititi OAO 979167 11 —14-0A0 MR 1 C:11;1 90 D DF , - L PERMIT CENTER FEB 1 7 1958 DATE 1/29/98 COMP NO. ALIGN N WALL FACE EXIST COLUMN CONFERENCE ROOM REASON AS -BUILT J# WOOD /HARBINGER DUWAMISH BACKFILL PHASE 11 #979167 DLR -JGA r%;LAPPAWArillf,G* SCALE_ T/8"'=V-( SCALE: NTS BUILDING 11 -14S.3 ARCHITECTURAL MASTER COL A -G/1 -7 KEY PLAN 979167 DM NO. A11.14S -3A10 PERMIT CENTER SYMBOL DATE B 1/15/98 . NEW MODULAR (VANGUARD) WALL SYSTEM FINISH TO MATCH EXISTING SYSTEM LOCATED AT THE OFFICES AT THE SOUTH END OF THE THIRD FLOOR. 5/8 GYP. BD. ON BOTH SIDES OF 2' METAL STUDS. HEIGHT = 9' -0 ANCHOR AS PER DETAIL 1/3A11. (PROVIDED AND INSTALLED BY CONTRACTOR) L%" CONSTRUCTION NOTES SAME AS FLAG NOTE #1 ABOVE EXCEPT TO INCLUDE 2" SOUND BATT INSULATION. OFFICE UNIT FURNISHINGS BY OWNER (TYPICAL). NEW DOOR, FRAME, AND HARDWARE. (DOOR: SOLID CORE FLUSH PANEL OAK VENEER. VENEER AND STAIN TO MATCH EXISTING. HARDWARE "YALE" `PACIFIC BEACH` LEVERED HANDLE, LATCH SET. HINGES, KEYED THUMB LATCH DEAD BOLT, WALL STOP AND STRIKE, TO MATCH EXISTING. FINISH TO BE POLISHED STAINLESS STEEL SEE SHEET A351. EXISTING CARPET SQUARE FLOOR COVERING TO REMAIN. INSTAL! NEW CARPET SQUARES TO MATCH EXISTNG BRAND AND COLOR WHERE OLDER NON- MATCHING CARPET EXISTS OR AREAS WHERE CARPET SQUARES DO NOT EXIST OR HAVE BEEN DAMAGED OR STAINED. (APPROX. 1% OF CLOUDED AREA) CARPET SQUARES PROVIDED BY BOEING, INSTALLED BY CONTRACTOR. NEW WALL TO BE CENTERED ON WINDOW MULLION. INFILL GAP BETWEEN WALL SYSTEM AND RECESSED MUWON WTEH PVC FILLER SLEEVE TO MATCH THOSE EXISTING AT OFFICE AREAS LOCATED AT THE SOUTH END OF THE SOUTH TOWER THIRD FLOOR. SLEEVE COLOR TO MATCH WINDOW MUWON. AS —BUILT j# WOOD /HARBINGER DUWAMISH BACKFILL PH. 12 #979167 DUWAMISH BACKFILL — PH. 11 #979167 6r APPROVED MME DLR JGA 7 -20 -92 SYM el_AdrAWAW • ACCEPTABILITY THIS DESGM1 WAR SPECIFICCON IS MIMED SSE: 1/8' =T' - gnu ar CHECKED 19 20 -Sll II CONSTRUCTION NOTES OFFICE UNIT FURNISHING BY OWNER (TYPICAL). PS EXISTING CARPET SQUARE FLOOR COVERING TO REMAIN. INSTALL NEW CARPET SQUARES TO !BATCH EXISTING BRAND AND COLOR WHERE OLDER NON— MATCHING CARPET EXISTS OR AREAS WHERE CARPET SQUARES DO NOT EXIST OR HAVE BEEN DAMAGED OR STAINED. (APPROX. 1% OF CLOUDED AREA) CARPET SQUARES PROVIDED BY BOEING, INSTALLED BY CONTRACTOR. ALTERNATE 1 -1i2'4 EMT CONDUIT BRACING OR MIL STUD @ 8' -0' O.C. SECURE TO STRUCTURE @ TOP OF W LL FIN. FL. LAY —IN TYPE SUSPENDED CEILING. NOTCH ABOVE WALL AT BRACE. STRUCTURE ABOVE FLATTEN EMT ENDS AND 00' ,,,)BEND i • VST STUDS O.CRTITION SOUND BATT INSULATION WHERE NOTED FLOOR TRACK FASTENED WITH POWER DRIVEN FASTENERS AT 24' O.C. T MODULAR WALL BRACING DETAIL 3 3A11 NTS FLOOR PLAN BUILDING 11 -14S ARCHITECTURAL MASTER COL G —M/1 -7 KEY PLAN SCALE: NONE SHEET f .3 .. C50ID "- LAST REVISION '•Il ilA d'ED oq7 3A11 R C CD FEB ` 7 V...•."38 PERMIT CENTER SYMBOL 00000 Al 1.145 -3A11 DATE 1/15/98 COMP NO. MASTERED ACCEPTABILITY TIcs ©EM MAR SWIM= AMMO NNWOWM Eft BEFG 1 B IS 06 -2 4 - 92 I BARBEE -29-92 99999.E TITLE ARCHITECTURAL MASTER COL REFLECTED CEILING PLAN BUILDING 11 -148 ;.3x8 W. A -G/1 -7 oxc rn. 00000 11.14S -3A280 COMP N0. E 6" X 48" RECESSED FLUORESCENT TROFFER (EXISTING U.N.O. ON LIGHTING PLAN) LEGEND CONSTRUCTION NOTES 2x4 RECESSED FLUORESCENT TROFFER 1x4 WALL MOUNTED FLUORESCENT TROFFER 2 L •• SC NT FLUORESCENT STRIP FLUORESCENT STRIP BEHIND GWB. L RECESSED DOWNLIGHT WALL MOUNTED HID OR INCANDESCENT 11 RECESSED DOWNLIGHT • RECESSED HID OR HPS 0: CEILING MOUNTED ILLUMINATED EXIT SIGN • WALL MOUNTED ILLUMINATED EXIT SIGN O CEILING MOUNTED SPEAKER Q SMOKE DETECTOR HVAC SUPPLY GRILLS N HVAC RETURN GRILLES • SPRINKLER HtAD ( EXIT SIGt1AGE RELOCATE ACOUSTICAL SUSPENDED CEILING PANELS AS REQUIRED TO PROVIDE FOR NEW LIGHTING, POWER POLE, HVAC, AND FIRE SPRINKLERING LAYOUT. PROVIDE NEW CEILING PANELS TO MATCH. EXISTING (ARMSTRONG CORTEGA MB 769A) WHERE REQUIRED TO REPLACE DAMAGED OR STAINED PANELS OR PANELS WHICH OTHER- WISE CANNOT BE REUSED WITHIN THE AREA OF WORK (CLOUDED) KEY PLAN LAST REVISION C'1 OF iUK\` O PP R ()YED !".PR .51988 DIVISiO RECEIVED CITY OF TuKvA A FEB, 1 7 1,99,8 P - RAT T CENTER SYMBOL B ? /15/98 A "AS- BUILT" BY WOOD/HARBINGER DUWAMISH BACKFILL - PH 12 #979167 DUWAMISH BACKFILL - PH 11 #979167 ACCEPTABI1.IIEY 14'15 gems 995)11 SESISIMION 51 APPRISED/ DEM SCALE 06 -25-92 SUBTRE ARCHITECTURAL MASTER COL G —M/1 - LEGEND 2x4 RECESSED FLUORESCENT TROFFER EH 1 x4 WALL MOUNTED FLUORESCENT TROFFER 2x2 FLUORESCENT I= 6"x48" RECESSED FLUORESCENT TROFFER (EXIST.) OgEl WALL MOUNTED FLUORESCENT CI= FLUORESCENT STRIP CONSTRUCTION NOTES li` RELOCATE ACOUSTICAL SUSPENDED CEILING PANELS AS REQUIRED TO PROVIDE FOR NEW UGHTING, POWER POLE, HVAC AND FIRE SPRINKLERING LAYOUT. PROVIDE NEW CEILING PANELS TO MATCH EXISTING (ARMSTRONG CORTEGA MB 769A) WHERE REQUIRED TO REPLACE DAMAGED OR STAINED PANELS OR PANELS WHICH OTHER — WISE CANNOT BE REUSED WITHIN THE AREA OF WORK (CLOUDED). F A WALL MOUNTED ILLUMINATED EXIT SIGN CEILING MOUNTED SPEAKER SMOKE DETECTOR HVAC SUPPLY GRILLS HVAC RETURN GRILLES • SPRINKLER HEAD KEY PLAN SCALE: NONE FLUORESCENT STRIP BEHIND GWB. RECESSED DOWN LIGHT WALL MOUNTED HID OR INCANDESCENT RECESSED DOWN LIGHT RECESSED HID OR HPS CEILING MOUNTED ILLUMINATED EXIT SIGN THIRD FLOOR PLAN - REFLECTED CEILING BUILDING 11 -14S LAS! REVISION 19LEET 'JOB NO. CITY 01 T!UKWI v0VED 11 AR 31998 DivISION C l^ Or JSVlLA F ES 1 ? ERI 41i CE NTER SYMBOL DATE C 1/15/98 3A281 I 11.14S-3A281 COMP N0. DOOR SCHEDULE-SOUTH TOWER