Loading...
HomeMy WebLinkAboutPermit D98-0052 - WASHINGTON STATE BEEF - WALLS AND LIGHTING FIXTURESWashington State Beef City of Tukwila �. Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • ' Tukwila, Washington 98188 DEVELOPMENT PERMIT Parcel No: 336590 -1881 Address: 14240 INTERURBAN AV S Suite No: Location: Category: AOFF Type: DEVPERM Zoning: C /LI Const Type: V -N Gas /Elec.: Units: 001 Setbacks: . North: 0 South: Water: N/A Sewer: ' " "N /A Wetlands: Slopes': Contractor OCCUPANT OWNER CONTRACTOR CONTACT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Signature:_ License No:';:: MMISEI *094P5 Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: East: .0 West: Streams: (206) 431-3670 D98 -0052 ISSUED 03/11/1998 09/07/1998 OFFICE 1994 SPRINKLERS .0 WASHINGTON. STATE BEEF' 14240 `:INTERURBAN AV S, .. TUKWILA: >WA 98188.. FAI RWAY CENTER ASSOCIATES R J CO INC, 12835 BELL -RED RD. #140, BELLEVUE WA M M I SERVICES INC. Phone: 206 882-3034 16533 NE 80 ST, REDMOND WA 98052 LEE SHEPHARD Phone: 425 -455 -9292 ;: A2835:,•_BEL -RED 'RD STE 140; BELLEVUE WA 98005:. r ****************************************************** * * ** * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: ADDITION; OF PARTITION WALLS, ANDRELOCATION. OF LIGHTING FIXTURES:: i************************************************.**** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 20,586.00. PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate)... Eng. `Appr: Curb Cut /Access /Sidewalk /CSS Fire Loop Hydrant. No. Size(in): .00 Flood Control Zone: Hauling: Start Time Land Altering: Cut: Landscape Irrigation: Moving Oversized Load: Start Time.:. Sanitary Side Sewer: No: Sewer Main Extension: Private: Storm. Drainage: Street Use: Water Main Extension: Private: Public: k * * * * * ** k * * * * * * * ** ************************' k********** * * ** *** * * ** * * * * ** * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 499.09 k******************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * ** * * * * * * * * * * * * * * ** Permit Center Authorized Signature:_ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Print Name: �? 1- )kr__2$4 This permit shall become null and void 180 days from the date of issuance, or for a period of 180 days from the last Date: 6 /14 ,,�� Date: 3 /iL1. $ if the work is not commenced within if the work is suspended or abandoned inspection. Addt'es`c 1.4240 TERURBAN ;AV 5 pe'r ni .i.C• :;No ' D98-0052 " . 5 u`i to TenantStatus ISSUED Type DEVPERM Appi ied 02/18%1998 ar :ce'l :# 36590 1881 Issued 03/11!1.99c • • ili.•ktt. *ck�*i;'k k*' k%kyk'k*`**•k ** k**.* k* ** k*_k'k* k•k* k•k*it;k*.'k k` k.k******�lr•k* k k k :* k'•k•k•k Ar k^k'lt'k** k. ** 'ermi t,.Cond,i tioris 1 Na changes `wi l,'.1. be' `made:: to ,the.: p.l arts, un l e.se• approved by the • • Architect or Engineers ng..Division 2 E,l ectt ^.i ca 1 : perms is :shad l bti giti"nw�Gtrough .t he 'Washington Mate Division ,ot�Ldtn and 'Ind resg''and a f,�J,• e l ectr i ca l o.rk w'i 11 be i rnsp�e •€e'd :by. ithat age '%y (248 -& 1) rneahanlca. Wortc nder� �separa' ier nt �a, issued by lie City of 'wi l e a n , f �' ti , .. 11 pe rmits , nspe : a p i t �recar�is;. and' appr'o 'e'd • rpr1ans , lta1.1. be a.v 1aka1 the jo site�, pri or, : t the :?sta `of any co y str uct :ici � rese ,,jdo c.urifeintw r {to be wa`i'.ntai sand avai l a r .� � � Y 7� 1 , > � _ fP . t iS able urr 1'fin'a�l inspection app :r oyal' i s grante �� �" ;� Any hp," ce i t ing gi,,1d and ;f .fi'cture • installlatip1t , is :� required 7 +nieet • dater a :a wing eluir ements for • ito� ids �, r r. $ f - i p t , R r ;t d to 'ceil ing ygrid nrus.t, be : lager a,l ly'k ? br ai d ifr o rer' eight (3)--..feet in leng Al onstruc ' to,vhe et/ In confofr"xnian wi "th app oved p l , � :.and �r egu.i rerne.nts wo1 tie Ur it or rn Bu iri'd i ng Code (1994' � `E'd'i!ti a • amended_, Un" to'rni Me'chcaa anr1 .Cade (1794 Edition :) an'dd asfi y r,gton ISt Energys^Codey = ( 994 Edi i on) . • 1441. t�I` cif e,;er�rnit. Th'e i suance`ktf rmit or .appr� oval io r I' WS � r—' , � oa pe ,�. R 1 nom '4461 tvl•dns , fand, 'shall• not be con- t ued t .be a'.p eiinnt tor, or :`'`a4) �ippwr.�civa`T of.; any v�zo[1atipn J rot ar}y of ,the provisions of the bru i i ii i,ng . `code Or of • any, f 7 s other ori:i fiance, of the • juri:die sort ,; No-- e rn) p {rzesurn1{ng t give,t au ttor~ity to'`violate'or cancel the pro. q t,sior.1, cad °'' be val id ,. Y al R CQUIRED FOR ALL NEW:ROO "AN • D' SPACES. OF NEW ,VENT.IUA' Ia (�i_� "� U �� r. 'f ;i OR EXT� TING . BUTL,DINGS ti IN CONFORMANCE '�WI�TH TI{E1`UNIFORM BUILDING .CODE AND :THE :Ww;HINGT0N 'STATE VENTILATION ! AND. : f INDOOR AIR ' , CODE , :CHAPTER 51 - ;':WA( 4 1, 1 Y ,i h 4l ty 3} Vt 4 }i f ITY: : ;u Protect Name/Tenant: Whe -AAIN !, a - ra - r +g 'eip.e - Existing use: ❑ Retail ❑ Restaurant ❑ Church ❑ Manufacturing ❑ School/College/University Vale of Construction: • ti 2o, 5156 . Site Address: City State/Zip: 14240 1•JT£yGUR, Ave.. 5, 81.4wPaJ6n." 6' -tvswlr.4.vM8166'365A Tax Parcel Number. n -1m l- °Glooxg0 -0mf - o Property Owner. Q.S. Neil1-401comAY CO. Phone: 2 .5 �- 4\55 -c Street Address: City State/Zip: 1 2®35 -IN#_p coo . s to o A. X40 tea-AAA tokAtod5 Fax N: 42,5 A-SS - 4016 Contact Person: LE t -Pte R-P Phone: '^J� Street Address: Sihm.,IL h AZDV . City State/Zip: Fax N: 'NIA Contractor: Mb*" ► Svg,v1L>=.S Phone: q25 -, gaz - o'S4M Street Address: 16533 N.E.. 'aOI 4 s esorvwr.►o, wA City Slate/Zip: qr?05o Fax N: 4 582 Architect: VeZe -AX t l t 60 (.Rey, Phone: �ZS - 1921- Street Address: 1727? 1 Tt-4. G.T. iv su ciV Zc3 City State/Zip: 1�tn.e+b KAMM. Fax N: � 3 � ' 2� - gZ ` - Engineer: v /�. Phone: Stre i; Address: City State/Zip: Fax Description of work to be done: / Ot Off - arri lo-) VvAri ANC getd?cAkrTtea ae 644 - rir 6 - c..1R.F'4 Existing use: ❑ Retail ❑ Restaurant ❑ Church ❑ Manufacturing ❑ School/College/University ❑ Multi -family ❑ Warehouse ❑Hospital ❑ Motet/Rotel 111 Office CI Other Proposed use: ❑ Retail ❑ Restaurant CI Church d Manufacturing ❑ School/College/Uhlversity ❑ Multi- family ❑ Warehouse ❑Hospital CI Motel/Hotel 110 Office ❑ Other WIII there be a change of use? ❑ yes I no II yes, extent of change: (Attach additional sheet if necessary). I Will there be rack storage? ❑ yes I no Existing fire protection features: I sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) • Building Square Feet: 51 7--• existing I Area of Constrtfction: (sq. ft.) 1,4 ‘0 Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 81/7 In the building? ❑ yes 1111 no X 11 paper indicating quantities & Material Safety Data Sheets CITY Of TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 88188 (206) 431-3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. i altii ' ' WI 41CAtr� EOU ' tl !p�lf��� r' , BWhqV CI Curb cut/Access/Sidewalk ❑ Flood Control Zone ❑ ChannellzatlonlStriping Cl Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer 0: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt N: Size(s): 0 Deduct ❑ Water Meter /Permanent N Size(s): ❑ Water Meter Temp N Size(s): Eat. quantity: gal ❑ Miscellaneous ❑ Hauling ❑ Landscape Irrigation 0 Private 0 Public 0 Private 0 Public 0 Water Only Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current lee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for sr period not exceeding leo days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application —� CTIERMIT.DOC 7/9/96 Data application pins: Applic kw by: (Initials) 0 i i r ..... A � NTIM leo 1 • ' e ), ..k(.''r ei s t . j. :11 !! : ,., ; yi . , . " ' ,,r i y, •• - • t .• : J Bu�LpIN(iO4yNI5R dA��AUr o , � >�, • � �, .., �4': �,�. �,,;.�._.,.� � �, ; � Q� ,�, �:,d�. � ��s,� , ,.��:� . �; a ;�{� } -,:.: Er.' Er.' , Signature: F .WIfi, I Date: 1' I lib Print name: TAAIJ us eIeANAr I Phone: 42S 2a 37e 3 I Fax f 42S 821 3213 Address 12.17.7 t34 ' w 6 . 30 " 2 City /State/Zip ite,04440 ANA lea ALL COLS1f 1ERCIAL/1111.1L TI- FA A1/111 TENAN If.1PROVE111ENT /ALTE ' ION PERMIT APPLICATIONS L1UST SUBrlITTED WITH TIIE FOLLOL ING: �, IL pRA1�I4GS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, c ' - STRUCTAMAL 'ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ 411 Complete Legal Description tI ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which Include : • ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' Intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with Irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if In flood control zone) 13. See Public Works Checklist for detailed civil/site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ U Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ill Vicinity Map showing location of site 111 ❑ Rack Storage: if adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, Include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ 111 indicate proposed construction of tenant space or addition and wails being demolished ❑ Construction details ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., root; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as Identified by the Fire Department. El 111 Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). 110 ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ . Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health Is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit Is issued OR submit Form 11-4, "Affidavit In Lieu of Certificate of Contractor ". I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERM17'.DOC' 7/9/96 :*kk**A k alhie * k* * •k kA .k*.i CITY :Gf l.;tlKw]:LA, WA 1'f�aihSMIT ' �ti 4.4.Aa4v{c,***kA':*h *h�F'Ak Ek*'* k: �e:* k `k *A•k *:4k4 *" *A **•*** ** *k ****: *•k ** TRAM MIT? Ntcm.:er R970:0723 ' , 304.25 0 3lil i o 10 :00 Payment: - Method: `C CI t�lai:atior : `MMI SERVICE5 In t: 91.H P.e.,riui`t No: D98- ;00;32.%: Type : DEVE L OPMENr• `.. Pa" ce1 ti p:: 3'3.6 -.i • "alts: ,Addi ^.�. : ` 14240" : AV SS.:', • • ToW Nees: 499.05.. This Payment 304.25 '. Total 'ALL Pmts 499M09,.. Balance: .00 •k , ∎ *•A.A * *• ili sik* * ** * *i* *A.4.0k *;A * * * *42ti A * * * * * * * * *i: " *tk * * * *A#i#kk * ** Account :Code Description :Amount 00.0/32.2.1.40. BUILDING ..-• NOIRES • 299.7.5, 000/386.904: STArE DUILIING SURCHARGE 4450 ai,•.,a4::d•!..aa,Za:!.r • • . . 14 ‘‘ . ' 1 " .. A . ‘ , , ..t , -k7i:.•)■• • .,1% . '10 - ilr . #t'741-,ir,'.14.1...4;; , .*:0 it"..4r4s C1T '4e • 1 0,14.9 b 0ujitr Paynierit Method ECHC'K NattiQr. ER R :.:E} ES ION' 7'. 7" ••• • '"" •!' ". • " • , • , Fermit No Q5 DLVPERM �EVELOPMEN1 PERM11 Site IAddres 14240 LNTERURBN . • • • Ttta1 Fe 4'33,Qq 1hi s ;;;8...,11 L Pmts 194 84 $3aIarc 304.25 * Account p't . 0v/345,83O PLAN CHECK - NQP4RE$ 194 84 • ..J ,_+'"'" ?• . COMMENTS: INSPECTION RECORD Retain a copy with permit INSPE • NO CITY OF TUIIVOLA BUILDING DIVISION 6300 Southcenter;. Blvd•, #100, Tukwila, WA 981 • a ' - � 14�3 cel Approved per applic&ble codes. Corrections required prior to approval. t.l 1206 431 -3670 T • = of inspection: F ` 14 (L& .til kJ s Inspector: �2 G 11 Date: • I � 1 1 J r $42,00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PrVc ;: TyPe — of insop ion: A @ ss:, Date called: f ,7--9; Special instructions: d ' 4 l�.- e-v'e Ca-LA b y., t (: f5 SA Date wanted: A a.m. Requester: Ph ne fyp 1 -'g .4 ' 01 Li ce INSPECTION RECORD Retain a copy with permit INSPECTION NO. :.: "�• . "T ,. CITY DF- °TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 1 Approved per applicable codes.: Receipt No.: f (206) 431 -3670 Corrections required prior to approval. COMMENTS: inspector: Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit ITV OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd: #100, Tukwila, WA 9818 Proi" addrM Special Instructions: Date Call Date wants p.m. Requester: ^•(1 �L1 ce Approved per applicable, codes. COMMENTS: Inspector oate:33 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule'reinspection. Receipt No.: Date: (206) 431 -3670 Corrections required prior to approval. Project: T e of insp on. Add tdurtor\ ate called: . 1 1 4 Special instructions: 2 v ei P-1 Date wanted: 1 qq 6 a.m. Requester: r — CJ Ph o eNo• 1 4...50( --Oty5 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I Approved per applicable codes. Receipt No.: INSPECTION RECORD Retain `a copy with permit (206) 431 -3670 Corrections required prior to approval. COMMENTS: 1 . s t ir t Inspector: Date:31(1 I '- $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: '1�� o � Project Name. 1 ���� . sv ` L Address°. l. Q VA 0 _i,-_> =yc i . \yr;., A Suite # Fire Department Retain current inspection schedule Needs shift inspection - r i'1t VN Sprinklers: Fire ATarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM Approved without co rection notice Approved .with.corre no ce :issued Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila; Washington 98188 • P►pne: (.46) 575-4404 • Fax (206) 5754439 ar Space Heat Type Q Electric resistance • All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included In the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing V–tt i /_„ ( — X 1 00 = • Concrete/Masonry Option p 0 yes Check here if using this option and if project meets all requirements for the Concrete/Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying a no assembly below. Envelope Requirements (enter values as applicable) Fully heated/cooled space Minimum Insulation R- values Roofs Over Attic Building Department Use 3 N) Ik All Other Roofs Applicant Address: mill ( . 6 ... T. t 5t.4 ire. 7...45 `-Z Opaque Walls e--- t I Below Grade Walls N/ A Floors Over Unconditioned Space /,,1 A Slabs -on =Grade —1(� Radiant Floors NI Maximum U- factors Opaque Doors • fa Vertical Glazing • - 15 Overhead Glazing MIN Maximum SHGC (or SC) Vertical/Overhead Glazing I N[A Project Info 1 .. � Project Address 4 24 ,.. � A \e. s. Date 2 .. 11 _18 �.� `L-Q t Crk ' ` C'' Building Department Use 3 11.114wAi. --P., v■Jjr 1 &l be Applicant Name: vg 1 , s 4 Applicant Address: mill ( . 6 ... T. t 5t.4 ire. 7...45 Applicant Phone: F w-, VvA °le t* 2... 42 "2 i -339 Envelope Summary Climate Zone . ENV -SUM !0`11 Washington State Nonresidential Energy Coda Compliance Forms Project Description I ❑ New Building ❑ Addition Alteration ❑ Change of Use Compliance Option Semi- heated space' Minimum Insulation R- values Roofs Over Semi - Heated Spaces' a� Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) 1 NIA 'Refer to Section 1310 for qualifications and requirements Notes: Au, wot `11-14N •Psght Ul l T14/ N AN efirsvArG NS lv 64 ENVSTD 0 Systems Analysis O't€co52. June, 1995 Insulation on interior - maximum U- factor is 0.19 Insulation on exterior or integral - maximum U- factor - 0.25 Opaque ConcretelMasonry Wall Requirements If project qualifies for Concrete/Masonry Option, st walls with HC z 9.0 Btu /ft'•'F below (other walls m - meet Opaque Wall requirements). Use descripti • s and values from Table 20 -5b in the Code. Wall Description (including insulation R-vaiue & posi • n) U- factor is Be IN 0 p. en HaA rers I LAP/Ale 6144 146)5 CITY OF TUKWILA FEB 1 8 1998 PERMIT CENTER All Insulation Installed? Opaque Walls R -11 Below grade walls (ext) R -10 Below grade walls (othr) R -11 Roofs over attics R30 All other roofs R -21 Floors over uncond.sp. R -19 Slabs -on -grade R-10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert OH Area % U U SHGC 00 -1514 0.90 1.45 1.00 15-2014 0.75 1.40 1.00 20.3056 0.60 1.30 0.65 30.4014 0.50 1.25 0.45 All Insulation Installed? Opaque Walls R -19 Below grade walls (ext) R -10 Below grade walls (otter) R -19 Roofs over attics R -38 All other roofs R -30 Floors over uncond. R -30 Slabs -on -grade R -10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert OH Area % U U SHGC 00 -2014 0.40 0 80 1.00 Forms 1994 Washington State Nonresidential Energy Code Compliance For 1302 Space Heat Type: For the purpose of determining building envelope requirements, the following two categories comprise all space heating types: Other: All other space heating systems including gas, solid fuel, all, and propane space heating systems and those aysterre listed in the exception to electric resistance. (continued at right) yes no no yes 1994 Washington State Nonresidential Energy Code Compliance Form nvelope Summary (back) Climate Zone 1 ENV -SUM Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. All walls R -11 insulation? <40% lazing Masonry all Criteria OK? (below) lazing All insulation installed? Opaque Walls R -11 Masonry walls (Int) U -0.19 Masonry walis(other) U -0.25 Below grade walls (eit) R -10 Below grade walls (otter) R -11 Roofs over attics R -30 All other roofs R -21 Floors overuncond.sp. R-19 Slabs -on -grade R -10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert. OH Area % U U SHGC 00-10% 0.90 1.45 1.00 10-15% 0.75 1.40 1.00 15.20% 0.65 1.30 0.80 20.25% 0.60 1.30 0.65 Electric Resistance ■ Heat? . Prescriptive Path Allowed 4 Component Performance ar S ystems Analysis Required <20% dazing All Insulation Installed? Opaque Walls R -19 Mazonry walls(int) U•0.19 Masonry walls (other) U-0.25 Below grade walls text) R -10 Below grade walls (otter) R-19 Roots over attics R -38 All other roofs R -30 Floors over uncond. R -30 Slabs -on -grade R-10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert. OH Area % U U SHGC 00 -20% 0.40 0.80 1.00 Masonry all Criteria OK? (below) All walls R -19 sulation2 <20% lazing Start Totals Area weighted IC: divide total of (HC x area) by Total Area Electric Resistance: Space heating systems which use electric resistance elements as the primary heating system including baseboard, radiant, and forced air units where the total electric resistance heat capacity exceeds 1.0 Wift of the gross conditioned floor area. Exception: Heat pumps and terminal electric resistance heating in variable air volume distribution systems. no yes yes no June, 1995 Concrete/Masonry Option* Assembly Description Wall Heat Capacity (HC) Assy.Tag H C** Area (sf) HC-ea 'tithe area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. "For framed walls, assume HC =1.0 unless calculations are provided; for all other walls Section 200 EEO CEIVED F TUKWILA 1 8 1998 PERMIT CENTER Project Info Project Address [ 4 a4 0 k,N c.kezio l ASV e. , . Date i .. (i , q '1 t•c 'J in " Fj For Building Department Use - 11A1,4,w I, , Wit CUR I 6 e Applicant Name: F.e ",J1‘.. L- +F ieejfv Applicant Address: (Z27 - 7 t 3# -rii. c. Nlr. S u tTv. r..„. Applicant Phone: czov -' WA oveosz.. 425-82i-3 Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft2 Allowe Area Covered Parking 0.2 W/ft Open Parking 0.2 Wife Outdoor Areas 0.2 W/ft Location (floor /room no.) _ Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking 0.2 W/ft Open Parking 0.2 Wife Outdoor Areas 0.2 W/ft Location Description Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x If) Covered Parking 0.2 W/ft Open Parking 0.2 Wife Outdoor Areas 0.2 W/ft Bldg. (by facade) 0.25 W/ft Bldg. (by perim) 7,5 W Not for building exterior_ choose either t acade area or the perimeter method. but not both) Total Allowed Watts . , Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 1 mars, 1994 Wasningeon Stab Nonresident.) Energy Coda Compliance Forms Alteration Exceptions (check appropriate box) Maximum Allowed Lighting Wattage (Exterior) Maximum Allowed Lighting Wattage (Interior) Proposed Lighting Waftage (Exterior Project Description I 0 New Building 0 Addition 13 No changes are being made to the ighting From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Proposed Watts may not exceed Total Allowed Watts for Irt for Total Proposed Watts may not exceed Total Allowed Watts for Exterior 1994 Washington State Nonreside "al Energy Code Compliance Form a Alteration • Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Lighting Summary LTG -SUM Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior (May not exceed Total Allowed Watts for Exterior) Total Alb Watts otal Proposed Watts June, 1998 Compliance Option Q Prescriptive t� Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) VED otal Proposed Watts CITY OF TUKWILA FEB 1 81998 PERMIT CENTER Use' LPA (Wlft Use' LPA (W /ft Painting, welding, carpentry, machine shops 2.3 Police and fire stations 1.2 Barber shops, beauty shops 2 Atria (atriums) 1 Hotel banquet/conference/exhibition hall 2 Assembly spaces ° , auditoriums, gymnasia theaters 1 Laboratories 2 Process plants 1 Aircraft repair hangars 1.5 Restaurants /bars 1 Cafeterias, fast food establishments 1.5 Retail A' 1 Factories, workshops, handling areas 1.5 Retail 8 Retail banking 1.5 Gas stations, auto repair shops° 1.5 Locker and /or shower facilities 0.8 Institutions 1.5 Warehouses ' storage areas 0.5 Libraries 1.5 Aircraft storage hangars 0.4 Nursing homes 1.5 Parking garages SeeSMon 1532 Wholesale stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools buildings, school classrooms, day care centers 1.35 Common area, corridors, lobbies (except mall concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office buildings, office/administrative areas In facilities of other use types (Including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.2 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers • Othe Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not Iimied by Code. Cleary Indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: I Check here if at least 95% of fixttres in the space meet all four criteria: 1. Fixtures are fluorescent, non-lensed, with only one or two lamps, and 2. Lamps are T -5, T -6, T-8 or PL, and 3. Lamps are 5 -50 Watts, and 4. Ballasts are electronic ballasts • Lighting Summary (back) LTG -SUM 1994 Washington State Nonresidential Energy Code Compliance Forms 1994 Washington State Nonreside r Energy Code Compliance Form Table 15-1 Unit Lighting Power Allowance (LPA) for Interior Lighting June. 1995 Footnotes for Table 15 -1 1. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2. The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3. Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4. For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6. Includes pump area under canopy. 7. In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8. For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9. For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10. For both Retail A and Retail B, light for free- standing display, building showcase illumination and display window illumination installed within two feet of the window are exempt. Retail A allows a Unit Lighting Power Allowance of 1,0 watts per square foot. Ceiling mounted adjustable tungsten halogen and HID merchandise display illuminaries are exempt. Retail B allows a Unit Lighting Power Allowance of 1.5 watts per square foot, including all ceiling mounted merchandise display luminaries. 11. Provided that u floor plan, indicating rack location and height, is submitted, the square footage for u warehouse may be defined, for ECEIVED computing the interior Unit Lighting Power Allowance, as the floor area not covered by rucks plus the vertical face area (access side OF TUKWILA of the racks. The height allowance defined in footnote 2 applies only to the floor area pot covered by racks. FEB 1 8 1998 PERMIT CENTER Project Info Project Address 142.4O tr\rr l t aAt 3 toe. S , Date 2 _ _,, FjU t C.ottJ G „415‘. For Building Dept. Use Tute-..w l L. w1A °lie 1 68 Applicant Name: F j14%114., l Fl✓ I;grJ44\1 Applicant Address: viz 7 134. Ti txr rs4e. 54 rre. 2 Applicant Phone: i-D oaO \n 1A ° 18052 42.5 ez -3383 Cooling Equipment Schedule Equip. ID Brand Name' Model No,' Capacity' Btu/h Total CFM OSA CFM or Eco SEER or EER IPLV Location C. l Fan Equipment Sched e Equip. ID Brand Na Model No.' CFM SP' HP /BHP Flow Control Location of Service C. l Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capac' /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' r I 1994 Washington State Nonresidential Energy Code Compliance Form q Mechanical Summary MECH -SUM 1994 Washington State Nonresidential Energy Code Compliance Forms June, 1895 Project Description Briefly describe mechanical system type and features. J AtcFf, K)4c uoRifc. WiL'( j3/ smpAgArs SST Compliance Option Equipment Schedules Q Simple System O Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex syster• . The following information is required to be incorporated with the mechanical equipment sch = • es on the plans. For projects without plans, fill in the required information below. %t( av ailable. 2 As tested according to Table 14-1, 14-2 or 4-3. 3 If required. ' COP, HSPF, Combustion Efficiency, or AFUE, as applicable. s Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). ItGECKatJtcAC, gei sEPARAZa Pete/141r ma B. UMIT60 ,eaocAZtoN c7F - sbPeal/p-ercieki oiFPvsggp of ey,Ls7' /nra aezr. a&S Itr667/N UNIT. • RECEIVED CITY OF TUKWILA FEB 1 81998 PERMIT CENTER System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: • Constant vol? Split system? • Air cooled? • Packaged sys? 64;000 Btuh or 1900 cfm? • • Economizer includ If Heating Only: ■ < <5000 cfm? < • 7 s de air't Heating Only Decision Flowchart 1994 Washington State Nonreside till Energy Code Compliance Form Use this flowcha ermine if project qualifies for Simple System Option. If not, either the Complex System o ems Analysis Options must be used. System Type <5000 cfm? <70% OA 54,000 Btu 1900 cfm it Cooled? Split tem? 54,000 Btu 1900 cfm? or Cooling Only Reference Sec. 1421 onstan olume C Reference Sec. 1423 J Simple System Allowed ackage yes stem? no V Coolin Reference Sec. 1420 Use Complex System Reference Sec. 1430 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. RECEIVED CITY OF TUKWILA FEB 1 8 1998 PERMIT CENTER j. ACTIVITY NUMBER D98 -0052 DATE 2 -18 -98 PROJECT NAME WASHINGTON STATE BEEF DEPARTMENT: :op • DIV ION ❑ Pt!: LI WOR ❑ REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F .41 PL / R OUTING IP LI P EVENTION PLArIG DMSION ❑ STRU r • ❑ P1RMTT C1INO • DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 2 -19 -98 COMPLETE j20 NOT COMPLETE ❑ NOT APPLICABLE ❑ COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) I I APPROVALS OR CORRECTIONS: (ten days) APPROVED ❑ APPROVED W/ CONDITIONS ❑. NOT APPROVED (attach comments) ❑ i CORRECTION DETERMINATION: DATE DATE DATE DUE DATE 3 -5 -98 DUE DATE APPROVED 1 APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Certiticadon of occupancy requited. City of Tukwila Fire Department Fire Department Review . Control #098 -0052 Thomas P. Keefe, Rre Chief Re: T.I. at Washington State Beef - 14240 Interurban Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, •1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 0 C City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, The Chief halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate'the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two dr more exits from a room or an area are Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phones (206) 5754404 • Fax (206) 575.4439 Page number 3 City of Tukwila Fire Department required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) .7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 City of Tukwila Fire Department Page number 9. All new sprinkler systems and all modifications to existing sprinkler systems shall ve 'fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have,the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other ' representative designated and /or recognized by The City of Tukwila, prior to submi to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required .fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 Page number. Fire Department requirements based on type of construction, draft stop partitions and roof coverings shall '' be' maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) . In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 57$4439 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 Phone: (206) 57$4404 • Fax (206) 575.4439 • ; ' ,•• • •. • • • • '•• • ' " 7' ' :• ! • •:`,. • • • l• • • 4. ■••■ • I •t: _2;r 1 • %.;,, • • :• ; • • , m rrl • .4 : • • • • t1C ." •- •23 •• • . • " R. ggi • '* • • •.• .4 • it3 .• • . • m . , , .. • . . • ,991 ;.',• • • • • • ..:3 g::' • . • .•::: ...:. (4 !:.M 11 ...;,• • ... • ••. .......,... • }••• : ....... : ;. .1 li :.;....; ,...:.,,...:,,"..: .: .• ., . ' ' :..;:;•:•: . '.:.• •• ... . .. .'K ,si N.+ t. • .;•.: '.". .'. .• • • '. .• : '., ..., ,;•:,••••;•••••••*. : . rn: ITI 1,7 ;,... , ...;•,,:.,:.',';!•..... ..r., ..• ,•:$. ,f± ‘...,r.. o. ....,...•-.......-::.:'. ' ' 17.1•• '.• -•,' •,':•. .;•,..••:::'......:. . ,, ...t....;.:.:•. ‘ , • ......,..71 11.% •1::;1••C'".•:i....4.......;,,••::: ..... ',. •-* ..,,....:' • . • En• . t ,'•': • ; ;.• • ...' • •.'.'•, ....: . Do ..,,.-- ' ' • 111C 2 1 4"Fl.....•-: 1: 1 1 ; .":" ■; : : : •: '• : : ,. ': ;:•.." . ...,., .........:::.,:::::::::' • •• • (J) • ••- rn Z ii ''••;:l.., '.....* • ,,,-;.,..... > ..., r , 0 I: ..';':::•:...!::,..; ,:. •'• ;•!•,•,....:,.. —I i, • o C . m . > (f) :t; :.• • • ..,.., ... O .0 . .s . ., .,... 11 '''' 13 M 11: :— ... • . .. x) - cn • ':',..•*:: : .. • '•''.•':.::, '..::..:::,: '.•,•••••••:. ,.o 1 ; ;.:•;;;......•:•:'.... ... • ,:.. •..., , ., 11 !...'• .-":!;:..,.• :..: .. 2 .??( 0 - -1 . 0 t: :;,..,...! 1 ... . , • ,, . 1, , .. Z ti ... ....‘,.. . `. • • > ' j: '.. ••• ... • ;•'.. ........'•':.:'.. : ,•'''• '...: . `"': : ' ''.. ... 1 1 .:. '"' 1/4. t •I ':...• • . .8 . • ;•" ' ''' '!' '. ' • %. • . • " • • • ` • . . ;, .. . • , GENERAL INTERURBAN AVE KEY PLAN 10 ,_ 0 „ FLOOR PLAN GENERAL NOTES I. MECHANICAL 2. ELECTRICAL 3. FIRE SPRINKLERS 4. FIRE ALARMS/PROTECTION A. VERIFY AND CONFIRM ALL DIMENSIONS AND EXISTING CONDITIONS. NOTIFY OWNERS REPRESENTATIVE FERRARI DESIGN GROUP (FOG) OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN OR PROGRESS OF WORK PRIOR TO FVCEEDING WITH THE ITEM OF WORK AFFECTED. B. COMPLY WITH ALL APPLICABLE CODES ANC ORDINANCES. LAWS AND ORDINANCES GOVERN IN CASE OF CONFLICT BETWEEN METHODS OR STANDARDS OF INSTALLATION OR MATERIAL QUALITY. NOTIFY (F06) OF ALL CONFLICTS. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE 1994 EDITION OF THE UNIFORM BUILDING CODE AS AMENDED AND ADOPTED BY THE CITY OF TUKWILA, AND IN CONFORMANCE WITH THE CITY APPROVED STAMPED DRAWINGS. A COPY OF WHICH SHALL REMAIN ON SITE AT ALL TIMES DURING THE COURSE OF CONSTRUCTION. G. OBTAIN SEPARATE PERMITS FOR ALL ADDITIONS AND /OR MODIFICATIONS TO: IN ACCORDANCE WITH AND AS REQUIRED BY ALL GODES AND REGULATIONS. D. COMPLY WITH REQUIREMENTS IN THESE SPECIFICATIONS FOR STANDARD OF WORKMANSHIP, PERFORMANCE, AND QUALITY. I. WHERE MATERIALS, FINISHES OR EQUIPMENT 15 NOT SPECIFICALLY IDENTIFIED, THE CONTRACTOR WILL BE REQUIRED TO SUBMIT SAMPLES OR INFORMATION DETERMINING QUALITY AND PERFORMANCE TO R.J. HALLISSEY GO. AND THE TENANT FOR APPROVAL, PRIOR TO ANY WORK. F. MAINTAIN STRUCTURAL INTEGRITY OF ROOF STRUCTURE. DO NOT USE 2 X 4 ROOF STIFFENERS FOR CEILING SUPPORT, SPRINKLER PIPE SUPPORT, MECHANICAL DUCT HANGER SUPPORT, ETC. DO NOT GUT STIFFENERS. ANY SUPPORT OF NEW LOADS ON EXISTING ROOF STRUCTURE MUST BE REVIEWED AND APPROVED BY A WASHINGTON STATE LICENSED STRUCTURAL ENGINEER. G. GLEAN UP: I. DAILY SITE CLEANUP: ALL RUBBISH MUST BE REMOVED AT THE END OF EACH WEEKDAY AND, WHERE THE SPACE 15 CURRENTLY OCCUPIED, VACUUMED IN THE IMMEDIATE WORK AREA. 2. FINAL CLEANUP: SCOPE OF CONTRACTOR'S WORK TO BE A COMPLETE TURNKEY CLEANUP OF THE ENTIRE TENANT SPACE INCLUDING, BUT NOT LIMITED TO, ALL FLOOR COVERINGS, INTERIOR WALLS AND GLAZING, INSIDE SURFACE OF EXTERIOR GLAZING, BATHROOMS AND DOORS CLEANUP IS NOT LIMITED TO THE IMMEDIATE WORK AREA. 3. DUMPSTERS: CONTRACTOR TO PROTECT ASPHALT SURFACES WITH WOOD BLOCKING OR SKIDS TO PREVENT DAMAGE TO THE PAVED SURFACES. NO _`:GALE OPEN OFFICE AREA 68'4" x E. COORDINATE SUPPLIERS AND SUBCONTRACTORS FOR PROPER SEQUENCE OF OPERATIONS; PREVENT DUPLICATION OF EFFORT; PROVIDE ORDERLY PROGRESS OF WORK. 2. 4. 5. 0 CONCRETE: METALS 6. CARPENTRY G. CABINETRY: DOORS, WINDOWS, HARDWARE 4d SCALE : 1/8" NO" SITE WORK: NO WORK OUTSIDE OF BUILDING IS A PART OF WORK OF THIS PERMIT. A. REPAIR OF TOPPING SLAB AREAS IF ANY WILL BE DONE PER ACI STANDARDS UTILIZING A LIGHTWEIGHT CONCRETE MATCHING EXISTING TOPPING SLAB. REINFORCING MESH AND VAPOR BARRIER IF ANY SHALL MATCH EXISTING. MASONRY: NO MASONRY WORK 15 A PART OF WORK OF THIS PERMIT. A. FRAMING: "GRABBER" OR EQUIVALENT, AS DETAILED ON DRAWINGS, WITH FIRE BLOCKING AS REQUIRED BY CODE. BOTTOM PLATE CONNECTION AT 24" O.G. B. FURRING: "GRABBER" OR EQUIVALENT, AS DETAILED ON DRAWINGS. FUR OUT RAIN LEADERS, CONCRETE PILASTERS AND COLUMNS AND SHIM CONNECTOR PLATES, ETC. AS REQUIRED TO COVER. G. PROVIDE GALVANIC INSULATION BETWEEN DISSIMILAR METALS WHERE IN CONTACT. A. GENERAL: FROVIDE BLOCKING AS REQUIRED FOR ANY PLUMBING FIXTURES, ACCESSORIES, CABINETRY, ETC. PLASTIC LAMINATE: "FORMICA" (COLOR APPROVED BY R.J. HALLISSEY CO. AND TENANT). I. CUSTOM -BUILT CABINETS AS DETAILED ON DRAWINGS, 2. PLASTIC LAMINATE FINISH ON ALL EXTERIOR SURFACES. ALL CABINET INTERIORS AND OPEN SHELVING TO BE OVERLAID WITH A MELAMINE LAMINATE. THERMAL AND MOISTURE PROTECTION A. INSULATION: ALL WORK UNDER THIS PERMIT 15 BEING PERFORMED WITHIN AN EXISTING INWLATED, FULLY CONDITIONED BUILDING ENVELOPE. INSULATION WORK 15 LIMITED TO ANY REPAIR REQUIRED TO MAINTAIN INTEGRITY OF EXISTING ENVELOPE. MANUFACTURED BY OWENS- CORNING, MANSVILLE OR EQUIVALENT. PROVIDE FLAME SPREAD 25 RATED FACINGS IF FACINGS ARE USED. I. PRIOR TO INSTALLATION OF INSULATION, CONTRACTOR MUST VERIFY A MOISTURE RATING OF 1496 OR LESS. 2. WHERE INSULATION IS PLACED ON TOP OF SUSPENDED CEILING SYSTEM. DO NOT INSTALL INSULATION ON TOP OF OR WITHIN 5" OF LIGHT FIXTURES, UNLESS FIXTURES ARE APPROVED FOR SUCH USE. 3. MATCH R- VALUES OF EXISTING INSULATION FOR ANY NEW WORK PERFORMED. 4. INSTALL VAPOR BARRIER ONLY TO REPAIR AND MAINTAIN EXISTING WHERE IT OCCURS. A. DOORS: 3' -0" BY T' -O ", 1 -3/4" THICK SOLID GORE WOOD, UNLESS NOTED OTHERWISE, MATCH EXISTING BUILDING STANDARD. VICINITY MAP ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. B. FRAMES: MATCH EXISTING BUILDING STANDARD. G. HARDWARE: D. GLAZING: 9. FINISHES A. FLOORING GYPSUM WALLBOARD: I. CUMBERLAND: STERLING NO SCALE ALL HARDWARE BY SGHLAGE LOCK COMPANY "D" SERIES LEVER LATCHSETS OR LOCKS!, TO MATCH EXISTING BUILDING STANDARD AS APPROVED BY RJ. HALLE., CO. INC. ALL HARDWARE USED IN ACCESSIBLE BUILDINGS AND FACILITIES SHALL CONFORM TO THE REQUIREMENTS PER "WASHINGTON STATE RULES AND REGULATIONS FOR BARRIER FREE DESIGN ", CHAPTER II STATE AMENDMENTS TCPTHE UNIFORM BALDING CODE. VERIFY KEYING REQUIREMENTS, SPECIALTY ITEMS AND QUANTITIES REQUIRED FOR COMPLETE INSTALLATION PRIOR TO ANY WORK. PROJECT GLAZING SUBJECT TO FEDERAL GLAZING STANDARDS AND GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. ANY MODIFICATION OR ADDITION TO STOREFRONT FRAMING AND GLAZING SHALL MATCH EXISTING STOREFRONT SYSTEM. I. CONTRACTOR WILL BE REQUIRED TO FIELD VERIFY EXISTING SLAB/SUBFLOOR CONDITIONS. ANY SLAB /SUBFLOOR PREPARATION REQUIRED PRIOR TO INSTALLATION OF FINISH FLOOR MATERIAL 15 WITHIN THE SCOPE OF WORK. 2. CARPETING: ALL INSTALLED CARPET SHALL BE DIRECT GLUE DOWN TYPE. CARPET CHOICES ARE AS FOLLOWS WITH FINAL SELECTION TO BE APPROVED BY R.J. HALL'S., CO. AND TENANT: 2. PHILADELPHIA "IMPACT II" - 30 OZ 3. BASE: 4" ROPPE VINYL BASE IN COLOR COORDINATED WITH FLOORING. VERIFY WITH RJ. HALLISSEY CO. AND TENANT. I. 5/8" GYPSUM BOARD, TAPED AND READY FOR PAINT. 2. ATTACH TO FRAMIN6/FURRING WITH I" G.W.B. SCREWS AT 8" O.G. AT PANEL EDGES AND 12" O.G. AT INTERIOR SUPPORTS. 3. 5/8" MOISTURE RESISTANT GYPSUM BOARD REQUIRED AT ALL INTERIOR WAJ.:LS IN RESTROOMS. 4. 5/8" TYPE "X" FIRECORE GYPSUM BOARD AT ALL RATED ASSEMBLIES WHERE NOTED ON DRAWINGS. �7 C�Z�7C MIN /III ■I - �- •■il'�" I � �nllsr� II it �:' al V V 10. SPECIALTIES EXISTING WALLS: I� REFLECTED CEILING PLAN PAINT, KELLY MOORS OR APPROVED EQUAL. I. GENERAL WALLS: ONE GOAT INTERIOR LATEX EGGSHELL ENAMEL TO COVER. 2. RESTROOM WALLS: NO NEW WORK REQUIRED 3. WOOD STAINS: MATCH EXISTING BUILDING STANDARD. NEW WALLS: I. GENERAL WALLS: ONE COAT LATEX PRIMER AND TWO GOATS INTERIOR LATEX EGGSHELL ENAMEL. 2. RESTROOM WALLS: NO NEW WORK REQUIRED 3. WOOD STAINS: MATCH EXISTING BUILDING STANDARD. D. SUSPENDED CEILINGS: USE EXISTING CEILING SYSTEM. REPLACE STAINED/BROKEN TILES. LAY -IN ACOUSTICAL BOARD: ARMSTRONG "MINABOARD": 2' X 4'. X 5/8" FISSURED PATTERN. VERIFY MATCH WITH EXISTING BUILDING STANDARD. 2. SUSPENSION SYSTEM, EXISTING 3. SUPPORT LIGHT FIXTURES WITH TWO NO. 12 GAUGE HANGERS FROM FIXTURE TO STRUCTURE ABOVE. LIGHT FIXTURES WEIGHING MORE THAN 56 POUNDS SUPPORTED BY 4 HANGERS, ONE IN EACH CORNER. 4. PROVIDE SEISMIC BRACING AS INDICATED ON THE DRAWINGS AND REQUIRED BY CODE. A. TOILET ACCESSORIES: EXISTING: NO NEW WORK. B. FIRE EXTINGUISHERS: PROVIDED BY GENERAL CONTRACTOR PER CODE. IN LOCATIONS SPECIFIED BY FIRE MARSHALL (ONE REQUIRED). II. EQUIPMENT, NO WORK IN THIS DIVISION 15 REQUIRED UNDER THIS PERMIT. 12. FURNISHINGS: NO WORK IN THIS DIVISION 15 REQUIRED UNDER THIS PERMIT. 13. SPECIAL CONSTRUCTION: NO WORK IN THIS DIVISION 15 REQUIRED UNDER THI5 PERMIT. 14. CONVEYING SYSTEMS: NO WORK IN THIS ON/ISION 15 REQUIRED UNDER THIS PERMIT. 15. MECHANICAL: ANY WORK REQUIRED WILL BE UNDER A SEPARATE PERMIT. A. PLUMBING: INSTALL AS REQUIRED AND PER CODE. MAKE PLUMBING CONNECTIONS AS REQUIRED TO EXISTING DOMESTIC WATER AND SANITARY SEWER LINES. USE COPPER PIPE, NO BLACK OR GALVANIZED IRON PIPES ALLOWED. POSITION FIXTURES PER HANDICAP ACCESSIBILITY CODE REQUIREMENTS. I. COFFEE BAR SINK: ELKAY 15" X 15" STAINLESS STEEL WITH ACCESSIBLE FAUCET. V SCALE : 1/8' _ NO" B. GAS PIPING: NO GAS PIPING ALLOWED UP OUTSIDE FACE OF BUILDING OR ABOVE ROOFING. GORE DRILL THROUGH EXTERIOR WALL. ATTACH PIPING TO INSIDE FACE OF WALL AND EXTEND UP TO ROOF STRUCTURE. RUN PIPING UNDER AND SUPPORTED FROM ROOF STRUCTURE. G. FIRE SPRINKLERS: ADDITIONS AND MODIFICATIONS AS REQUIRED BY CODE AND NFPA PAMPHLET 4 13. SPRINKLER HEADS CENTERED WITHIN CEILING BOARD WHERE FEASIBLE. C. HEATING, VENTING AND AIR CONDITIONING: MODIFY EXISTING AND INSTALL NEW AS REQUIRED AND IN ACCORDANCE WITH ALL APPLICABLE CODES AND REGULATIONS. 16. ELECTRICAL: ALL WORK WILL BE BY SEPARATE PERMIT. INCLUDE OUTLETS, SWITCHES, SEPARATE SERVICE, OVERHEAD SUPPLIED TELEPHONE AND POWER POLES, ETC. COMPLETE. A. POWER PANEL: VERIFY EXISTING SERVICE LOCATION, SIZE, CAPACITY AND ANY DESIRED RELOCATION WITH RJ. HALLISSEY CO. INC. B. OUTLETS AND WIRING: INSTALL AS DIRECTED BY R.J. HALLISSEY CO. INC. AS TO QUANTITY, TYPE AND LOCATION AND A5 REQUIRED BY ALL APPLICABLE CODES. VERIFY DEDICATED CIRCUIT LOCATIONS WITH TENANT, ALL CONDUCTORS SMALLER IN SIZE THAN A 46 SHALL BE COPPER. TERMINATE ALUMINUM CONDUCTORS WITH GABLE TERMINATORS. G. TELEPHONES: INSTALL PULL WIRE IN :.WALLS TO LOCATIONS INDICATED BY TENANT FOR TELEPHONE OUTLETS ONLY. ALL WIRING AND INSTALLATION OF TELEPHONE SYSTEM FROM BUILDING ENTRY POINT IN N.I.G. (BY TENANTS VENDOR). D. COMPUTER DATA LINE: COORDINATE WITH TENANT PRIOR TO INSTALLATION. PROVIDE MUD RING AND PULL STRING TO LOCATIONS INDICATED BY TENANT, ALL WIRING AND INSTALLATION OF COMPUTER SYSTEMS' 15 N.I.O. (BY TENANT'S VENDOR). E. POWER POLES: VERIFY IF REQUIRED WITH TENANT AND R.J. HALLISSEY CO. INC. F. LIGHTING: RELOCATE EXISTING 2X4 FIXTURES. I. GENERAL: 2' X 4' 3 -TUBE LAY -IN FLUORESCENT FIXTURES. 2. LAMPS: SYLVANIA 4F-40/ON/RR. 'COOL WHITE" 34 WATTS PER LAMP RATING. 3. RESTROOMS: EXISTING LIGHTING TO REMAIN. PI2 Ch I _ .7e dlha ti t Peral4 kb, LEGAL DESCRIPTION LOT I-1 OF BLOCK IB HILMANS SEATTLE GARDEN TRACTS PROJECT DRAWING INDEX AI VICINITY MAP, KEY PLAN, FLOOR PLAN, REFLECTED CEILING PLAN, PROJECT DATA, PROJECT CONTACTS, LEGEND, KEY NOTES, DRAWING INDEX, AND GENERAL NOTES AS DETAILS, SECTION, AND INTERIOR ELEVATIONS PROJECT DATA: PROJECT ADDRESS: TYPE OF CONSTRUCTION, OCCUPANCY CLASSIFICATION, TOTAL BUILDING AREA: TENANT AREA: 201e, TAX PARCEL NO,, PROJECT CONTACTS: • SNEER / AGENT: TENANT, ARCHITECT, CONTRACTOR LEGEND EXIST. WALL TO REMAIN NEW OFFICE PARTITION WALL PER DETAIL I /A2 GORDON MOORMAN EXISTING 2X4 SUSPENDED CEILING GRID TO REMAIN _ �I EXIST. 2X4 (3) TUBE I ll FLUORESCENT LIGHT FIXTURE TO REMAIN 2 XIXTURE PJ-4 (3) UORESCENT LOST � NEW 2E4 (E) TUBE J - \ II I - FLUORESCENT LIGHT FIXTURE LOCATION REMOVE/RELOCATE EXIST. EXIST. SUPPLY AIR DIFFUSER TO REMAIN SEE MECH. DW65. RJ. HALLISSEY COMPANY 12835 BEL -RED ROAD, SUITE A140 BELLEVUE, WASHINGTON 98005 PHONE: (425) 455 -9292 FAX (425) 455 -2016 CONTACT: LEE SHEPHARD WASTE MANAGEMENT INCORPORATED 1120 ANDOVER PARK EAST TUKWILA, WA 98488 PHONE: (206) 515 -2250 FAX: (206) 515 -2260 CONTACT: PATTI BRUMBACH KEY NOTES CS' FERRARI. DESIGN GROUP 1227 134TH COURT N.E., s 203 REDMOND, WASHINGTON 98052 PHONE: (425) 821 -3383 FAX: (425) 521 -5215 CONTACT, FRANK HEFFERNAN, AIA MINI SERVICES 16533 N.E. 80TH STREET REDMOND, WASHINGTON 98050 PHONE: PHONE: (425) 882 -3034 FAX: (425) 682 -2003 LICENSE N0.: MMISEI "094P5 NEW 3' -0" X T-0" PERSONNEL DOOR, 1 1\2" PR BUTTS, 3SILENCERS, WALL STOP, LEVER PASSAGE SET. NEW PAIR 2' -0" X FULL HEIGHT RECITES \ (HEN 2 -0" X FULL HEIGHT RELITE 1341 II {4ULti WATev, ,*t5SC l,n3LV EXISTING BUILDING STRUCTURAL COLUMN VINYL FLOORING CARPETING EXISTING DOOR TO REMAIN 14240 INTERURBAN AVENUE SOUTH BUILDING "B" TUKWILA, WASHINGTON 98168 VN SPRINKLERED B - OFFICE 51,,122 S.F. (BUILDING 5) 2,926 S.F. MI s 356590 - 1811 - 06/00280 - 0001 -00 EXIST. SUPPLY AIR DIFFUSER TO REMAIN SEE MECH. DINGS. EXIST. RETURN AIR DIFFUSER TO REMAIN SEE MESH DWG, REMOVE/RELOCATE EXIST. SUPPLY AIR DIFFUSER SEE MECH. DINGS. NEW/RELOCATED RETURN AIR DIFFUSER SEE MECH. DWGS. EXISTING PHONE JACK EXISTING DUPLEX ELECTRICAL OUTLET KEYNOTE DESIGNATION BUILDING GRID LINE NEW LIGHT SWITCH SEPARATE PERMIT REQUIMC.D rOR: M EC :',C:AL E .LEG i `.=,'.. I 0PLUP.; ;Q I AG BUILDUvr, LIUU9IQl D co s2 FERRARI DESIGN GROUP ARCHITECTS, PS 12273 134 COUR NE TH SUITE 209 REDMOND WA 425.82.3 425.527.3383 ARCHITECT: PROJECT: Tenant Improvement For: Waste Management Inc. Fairway Center Building 'B' 14240 interurban Ave. S. Tukwila, WA SHEET TITLE: General Notes, Key Plan, Vicinity Map, Building Data, Details, Floor Plan, Reflected Ceiling Plan, OWNER / TENANT R.J. Hallissey Co. Inc. Bellevue, WA Waste Management Inc. Tukwila, WA Revisions: A ■ of 2 Job No.: 04040.19 En i. rL;;TEa. Pgb- ooP52_ 3 I/2' METAL STUD FOR LATERAL SUPPORT. ATTACH W /42)H6 SCREWS SCREWS T.4B. EXTEND STUD TO ROOF STRUCTURE /WHERE RECUT D BY CODE/ SUSPENDED ACOUSTICAL CEILING BOARD ATTACH TOP TRACK TO MAIN RUNNER OR CROSS TEE a POINT OF INTERSECTION W/ (I) TYPE 'S' SCREW. 5/8' GLUE, EACH SIDE ATTACH W/ TYPE 'S' SCREWS a 8' PANEL EDGES 4 12' FIELD. - 3 12' X 25 GA METAL STUD ®24' O.C. ATTACH BOTTOM TRACK A 24' TO FLOOR 0T'FIC4L OFFICE PARTITION WALL O NOTE: CONFIRM EXISTING CEILING SUSPENSION CONNOR1S TO ABOVE DETAIL ANT NEW WORK SHALL ALSO BE SECURED ACCORDING TO THIS DETAIL - 12 GA. GALV. HANGER WIRE a 4' O.C. 12 GA GALV. SPLAYED WIRE A MAIN RUNNER 45' a12' -0 OL. FASTEN TO STRICTURE ABOVE WITH FIRST POINT 4' -0' FROM EACH WALL SEISMIC HOLD DOWA / RIGID STRUT 3 TIGHT TURNS - TYP. 45° NOTE, ALL ONE SMALL WE SOFT ANNEALED GALV. SCR STEEL WIRE CEILING SEISMIC BRACING DETAIL Scale: 3/4'•1' -0' FIELD VERIFY THIS DIMENSION COFFEE I5AR ELEVATION Scale 1/2 =1 -0 v a n ; VAR 5 15''5 ri FERRARI DESIGN GROUP ARCHITECTS, PS 12277 T34 COURT N E SUITE 203 REDMOND 98052-2433 425.82.338 425.8:1.3383 ARCHITECT: PROJECT: Tenant Improvements For: Waste Management Inc. Fairway Center Building 'B' 14240 Interurban Ave. S. Tukwila, WA SHEET TITLE: Interior Elevations and Details OWNER /TENANT: R.J. Hallissey Co. Inc. Bellevue, WA Waste Management Inc. Tukwila, WA Revisions: 2 01 Job No.: 94040.a FER, GEi ae, -- 81 V V / / \ / II I I L PI fl II II 11 REF II NI.C. U ' RUBBER LL BASE 15'X15' STAINLESS STEEL BAR SINK 4' BACK SPLASH, c �� � �/ V / ( \ U I / \ 4' TE AREA 2' -1I'S 30' 2 -0' REFRIG. AREA Pgb- ooP52_ 3 I/2' METAL STUD FOR LATERAL SUPPORT. ATTACH W /42)H6 SCREWS SCREWS T.4B. EXTEND STUD TO ROOF STRUCTURE /WHERE RECUT D BY CODE/ SUSPENDED ACOUSTICAL CEILING BOARD ATTACH TOP TRACK TO MAIN RUNNER OR CROSS TEE a POINT OF INTERSECTION W/ (I) TYPE 'S' SCREW. 5/8' GLUE, EACH SIDE ATTACH W/ TYPE 'S' SCREWS a 8' PANEL EDGES 4 12' FIELD. - 3 12' X 25 GA METAL STUD ®24' O.C. ATTACH BOTTOM TRACK A 24' TO FLOOR 0T'FIC4L OFFICE PARTITION WALL O NOTE: CONFIRM EXISTING CEILING SUSPENSION CONNOR1S TO ABOVE DETAIL ANT NEW WORK SHALL ALSO BE SECURED ACCORDING TO THIS DETAIL - 12 GA. GALV. HANGER WIRE a 4' O.C. 12 GA GALV. SPLAYED WIRE A MAIN RUNNER 45' a12' -0 OL. FASTEN TO STRICTURE ABOVE WITH FIRST POINT 4' -0' FROM EACH WALL SEISMIC HOLD DOWA / RIGID STRUT 3 TIGHT TURNS - TYP. 45° NOTE, ALL ONE SMALL WE SOFT ANNEALED GALV. SCR STEEL WIRE CEILING SEISMIC BRACING DETAIL Scale: 3/4'•1' -0' FIELD VERIFY THIS DIMENSION COFFEE I5AR ELEVATION Scale 1/2 =1 -0 v a n ; VAR 5 15''5 ri FERRARI DESIGN GROUP ARCHITECTS, PS 12277 T34 COURT N E SUITE 203 REDMOND 98052-2433 425.82.338 425.8:1.3383 ARCHITECT: PROJECT: Tenant Improvements For: Waste Management Inc. Fairway Center Building 'B' 14240 Interurban Ave. S. Tukwila, WA SHEET TITLE: Interior Elevations and Details OWNER /TENANT: R.J. Hallissey Co. Inc. Bellevue, WA Waste Management Inc. Tukwila, WA Revisions: 2 01 Job No.: 94040.a FER, GEi ae,