Permit D98-0091 - EXODUS COMMUNICATIONS - GENERATOR, FUEL TANK AND SHOWERS
D98 -0091 2811 S. 102n St. Exodus Communications City of Tukwila t; Parcel No: 042304 -9182 Address: 2811 S 102 ST Suite No: 160 Location: ' Category: AOFF Type: DEVPERM Zoning: MIC /H Const Type: V -N Gas /Elec.: Units: 001 Setbacks: North: Water: UNKNOWN Wetlands: Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. .0 South: Sewer: Slopes: Contractor License No: SABEYC *141PH OCCUPANT EXODUS COMMUNICATIONS 2811 S 102 ST, TUKWILA WA 98188 OWNER BOEING Permit Center Authorized Signature: epA n.-1' W. 2-X0 DEVELOPMENT PERMIT . LJAL * Permit No: Status: Issued: Expires: Streams: (206) 4313670 D98 -0091 ISSUED 05/07/1998 10/13/1999 Occupancy: OFFICE UBC: 1994 Fire Protection: SPRINKLERS /AFA East: .0 West: .0 CONTACT BRENT BIRD Phone: 206 -281 -8700 SABEY CORPORATION ARCH GROUP, 101 ELLIOT AV.W, SUITE.330, SEATTL CONTRACTOR SABEY CONSTRUCTION INC. Phone: 206 281 -8700 101 ELLIOTT AVENUE WEST #330, SEATTLE, WA 98119 • A* k A' A* k k******** **'A*•k•k** ****�A**** **'A*•A ******• k• k• k*• k' k• k*** ****•k•k***•k**•A**'A'A'A•A *'A* 4 Permit Description: INSTALLATION OF A GENERATOR IN AN EXISTING MECHANICAL ROOM, INSTALLATION OF.A FUEL TANK ADJACENT TO MECHANICAL ROOM, MODIFICATIONS TO EXISTING RESTROOMS TO ALLOW FOR ADDITION OF TWO SHOWERS'. ********************************************AA****************************************** Construction. Valuation: $ 95,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate). Eng. Appr: Curb Gut /Access /Sidewalk /CSS: N :Fire Loop. Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut:: Landscape Irrigation: N Moving Oversized Load: N Start Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private:. N Public: .N *• AA *•A**•A•k•**'k **'k* *'k * **•k'k* Arc**• A*******• k• k*******• kk****• A• k' A*• k****' k ** * * *•k•k * *•k•k* *•k *•A•A*k*•k•k TOTAL DEVELOPMENT PERMIT FEES: t 1,416.90 • A*' A**• A****• A*• A*•A* *•k•A•A *•A ** **• * * *•A* * *•A *•A•k* .A * * .k AA ***• k**• k• A• k •k *** ***'A * ** * *•A * * * *•A *•A *•k•A Sizetin) .00 End Time: Fill: End Time: Date: I -- a- L I - 2 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. S ignature _ (a„ Date ` ED Print NameXQ__k_\s* This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. 042304 -9182 2811 S 102 ST 160 AOFF DEVPERM MIC /H V -N 001 North: .0 South: UNKNOWN Sewer: Siope.s:. Contractor License No: SABEYC *141PH OCCUPANT EXODUS COMMUNICATIONS 2811 S 102 ST, TUKWILA WA 98188 OWNER BOEING CONTACT BRENT BIRD `:Phone: 206 -281 -8700 SABEY CORPORATION ARCH GROUP, 101 ELLIOT AV W, SUITE; '330, SEATTL CONTRACTOR SABEY CONSTRUCTION INC. Phone: 206 281 -8700 101 ELLIOTT AVENUE WEST #330, SEATTLE, WA 98119 c k*• k********* * ** * * *. * * * * * *. * * * * * ** * * * ** *. * ** k***************' k•k* * *****. * * *.k' * ** ** * * * * * * *** Permit Description: INSTALLATION OF A GENERATOR IN AN.EXISTING .. MECHANICAL ROOM, INSTALLATION OF A FUEL TANK ADJACENT TO MECHANICAL ROOM, MODIFICATIONS TO EXISTING RESTROOMS TO ALLOW FOR ADDITIONLOF TWO SHOWERS., * ***********.***************** k******** k ***********.*****k *kk * *k** * *4k ** k'k; * k * *'k ** ***** Construction Valuation: $ 95,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate).::'Eng::Appr: Curb Cut /Access /Sidewalk /CSS: N ,Fire .Loop Hydrant: N No Size(in) :. .00 Flood Control' Zone: N Hauling: N Start Time: Land Altering: N Landscape Irrigation: N Moving Oversized :Load: N Start Time: Sanitary Side Sewer: N No : Sewer Main Extension: N Pr.ivate.: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N, Public: N k***************************************.**.*****.*:** k*.* * ** ** * **** * * * * * ** * * * * *** ** ***** TOTAL DEVELOPMENT PERMIT FEES: $ 1',416.90 k********* * * * ** * * * * ** ** *** * * * * * *** * ** * * *® ************ * *** * ** * *'k * * * *** * * * * ** * * * * * * ** Permit Center Authorized Signature: Signature: Print Name: DEVELOPMENT PERMIT This permit shall become null and void 180 days from the date of issuance, or for a period of 180 days from the last Fire East: C ut: . Permit No: Status: Issued: Expires: Occupancy: UBC: Protection .0 West: Streams: Date: (206) 431 -3670 D98 -0091 ISSUED 05/07/1998 11/03/1998 OFFICE 1994 SPRINKLERS /AFA .0 P,ubl ic: Date: .Cq I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permi/ if the work is not commenced within if the work is suspended or abandoned inspection. 1Z.-c 1 2O CITY OF TUKWILA Address: 2811 S 102 ST Permit No: O93 -0091 Suite: levant: Status: ISSUED Type: DEVPERM Applied: 03/23/1998 Parcel #: 042304-9182 Issued: 05/07/1998 A:k kA•kkkk:k::*,tkA:k¢:•kkw*AA*•*k'kk1 *kR:tk•1:•kA.k* t:' **** .*'** l :kkkyk•kA kkk'k•J:kkk•k•kkkk:Az* Permit Conditions: 1. No changes w i l l be made to the plans unless approved by the Engineer and the Tukwila Building D.ivis.ion. 2. Plumbing permits sha1.1. be . obtained through the Seattle-King County Department Of Public Health. P1 umbing ,wi 11 be inspected by that ' agency, including all gas piping (296-4722). r I ectr i ca l ..}. ermi is Shall be obtained through the Washington State Division of Labor and ,industries and `all' r'le}ctr:i.cal work will ±.15 AnSPected by that agency (248 -6630 . 4. All mechanical, work shall b,e under separate permit issued by the City of Tukwila. >. All permits, insPec:t.ion..records., and approved plans' shall.be available at the job site prior to the start of - any: c:on- struction,. are to be maintained'` and avail able until final inspection approval is granted. 6. All' structura.l concrete shall be .Speec.ial inspected (UBC; Sec::,:306(a)11'. 7. All -structural welding shall be One . by W. A,8 :0, certified welders..and special inspected (UBC - .Sec. ;306(a)5) 8. liolts installed in concrete — shall be special ins.pected.,._., (HBC. e 1701.5.2) . 9. When special .ins.pectian'is required either, the owner„ architect: or engineer shall notify the Tukwila SRriiding Di.ieiori of appointment of the .inspection agencies: prior to :`;; the first building inspection: :Copies of a.l ± pecia.l•.. inspection reports shall be submit.t to:the :`8ui;ldinq :. Division in a timely manner. Reports. shall 'Contain address:, project name, permit number an d type ., inspection performed. 1D. The special inspector shall submit a final s.ignedreport stating whether the work requiring special 1nspec.tiott "Was; to the best ')f the inspector's, knowledge, in conformance with approved plans and specifications and the app,l_icable workmanship provisions of the URC.; • 11. All construction .t:o: be„ done in conformance .with: approved plans and r equ i cements off the ,Uniform :Bu i_1-d i ng I. (1997 Edition) as amended, Unil'carmMechan:i.cal Cade (1997 Edition), and Washington State Energy Code '(1997 Edition). 12, Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for or an approval of any violation of any of the provisions of the building code or of any other ordinance of the j u r i s d i c t i o n . No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. CITY OF TUKWILA Address: 2811 S 102 ST Permit No: D98-0091 Suite: Tenant: Status: ISSUED Type: DEVPERM Applied: 03/23/1998 Parcel #: 042304-9182 Issued: 05/07/1998 ************1f***********************k*k**********A.**4rA*************4. Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the:TpkwilaBuilding Division. 2. Plumbing permits shall,bfeobt'ainadjhirOUgh_the Seattle-King County Departmentof:Tublic Health. PTUMOTing.,will be inspected by thae „including all gef01 ..(296. 3. Electrical be obtained thrOm4h::the'WaShington. State Div of Labor and Industries andall*Olecbrtcal work 4i11 be inspected by that agenCy42486630 4. All mechanic aT4Ork shall be under separate permit:issUed by • the City yof TUkwila • _ , _ . S All permits, inspeetionrecords, and approved4)linhale available:,:at the oh site 'prior to the start of struCtlonThese docuMents:areto be maintalnecLandaVail inspection approval is granted. All-,. concrete hall be special inspected(U@C, Sed.-;:306(a)'1), 7. All structural welding hall be:*done certified '!Y, wel sPecialpeoted JUIW*Sec„:306(a)5). 8. Bolts instal Ted, in - concrete , be, inspected (UBC: Sec'. 1701.5.2) 9. WhenspeOlal :inspe41on lsyreqpired:' the owner, architect or engine shall notify the'j4Wila Building DiOSiOnOf'appointment of the inspec tion agevci es pr ior to tirt building inspection. CoOiefs in$0006nreports shall be submittetf.tOthe_Buildin, Division In a timely manner. R,eportsr06Y e s 1 project name, per Mit number ancLtype„cf,inspeCtion being/ performed. • 10. The special ins submit a final • stating whether the work'requirny inspeCtlory;WaS, to the beit:,,of the inspector'sYk6bwledge, in ccinforM'ane with approvedlans and speCificatiOns and the app:Oable . workmanship prOvl,sions of tileAl3C. 11. All oonstructione done Ii, conformance wit) approved plans and requireMentS Uniform_Au (1994 Edition) as amended, Unif'orM:'.HeOian*O4J (1994 Edition), and Washington State Energ) - (i994Edition). 12. Validity of Permit. The issuance of a permit or approval of plans, specifications, and comoitations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. Projec ..Name/Tenant: r X r_"u`. L /VI /Vlu'.) i C- Clil.� ;' t V Value of onstruction: 5 coo , ca Site Ad ess: //0// 2.. 1�C2e Sy- City State /Zip: (? T r v� _crt) i k '�fff ti l CA - L, Ai r <* : (Y7r Tax Parcel Numb cmetz=f2cyfq f e.'C - ("z Phone: 067 E'i - & To ° 11,0kit Propert Owner: S -6' Y C Q:.s;r- Street Address: .._ I City State /Zip: I C0) 1. =11. /!7' — 7 "iff` X�l c her 771 WA li Fax #: Zr .) . ee)! - C9?-0 Contractor: Esc, Phone: Z, - 2,b 1 --- F25700 . C (-- c rio J Street Addres3;-- / `� City State /Zip : - 1 ) f rrr i✓; t7 7)01 "1� C l li9 Fax #: 2 O ? I - 09 CO Architect: / - 1 ), - C�R. � , c_44 r c%`(i Czg x;p Phone: (_, .. - 2R)) - a5700 Street Address: City t to /Zip: City 5/19 / n r w ��0t Fax #: ca 7 I -09U) Enginee g ,"./C_ - 1 5 )0(" Phone: / y � - {� zoc Jz l lJ Stree Address: City State/Zip: & R FR �OQ L 4 tLti / { i li /"'ire ' y A Fax #: r �� •, 7 (_/ O C� 7� 6 & OL Contac erson: ---, - 7' 1 1 r u Cam►.(' Agar C- tut ee; } Phone: ��00 :t .� Zb1 f Street Address: City St t , ip: I C ( - et-L-1077' I 1 ( V Su )'T ��T I I(9 Fa # c - 2� - ( ZC Description of work to be done: 1,,,j ..t -r- (te°* - tj Gp- ,r c -- ,,, /,i) ,d Q 7 - /i4 1,11. /GfjZ •� ,1, � I, t T. va=TZO ell l= .4- I ut '721-A) tom. Al �j4 V C—C4- 1'�vtc.12-. ,M • /�/C 177 1 t" in , 1, - bX15 - r1ti'--r e=`1YP--oc n'f T ArU- r-OR -• Ml7JDiri t) o 'T100 S►-(4 i.rJ 5 . Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office El School /College /University OtherJv2 Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ther C> -Of f' Will there be a change of use? ❑ yes no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 7 Existing fire protection features: sprinklers Oautomatic fire alarm ❑ none ❑ other (specify) Building Square Feet: I T (Q / 0 t . existing Area of Construction: (sq. ft.) -1 Will there be storage of flammable /combustible hazardous material in the building? ar yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Safet Data Sheets CITY OF TUKWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC. WORKS SITE/CIVIL PLAN REVIEW OR THE FOL'LOWIN (Additional reviews may be determined by. the :Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt ft: Size(s). 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal ❑ Miscellaneous ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation 0" Private 0 Public 0 Private 0 Public 0 Water Only Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale application accepted: 34 —l1B Date appllca4z3..ra plr Applicat ken by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM CTPERM1T.DOC i /29/97 BUILDING 0 E' OR AUTHORIZED , ENT: Signature: . -, , „ Date: , .0( t, Print name: '`. « .M 1 Phone: , _ - Fax O's ' Address j 0 ( • q :l.4., -1 r-1 A id cDo ( ,;7730 City /State /Zip ,\ijk 9e.,(1 ALL COMMERCIAUMULTI-FAILY TENANT IMPROVEMENT /A 'ArION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOL 0 WING: ➢ n pRAWtej 3a O BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, 5TR O CTURALENQINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Complete Legal Description n - ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ Cl Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. El ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF HE STA OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. C'IPERMIT.L)OC 1/29/97 * 4 7Vkkk k* k- kk*{ A* 4 4. A* k** t* EA* A**/s A; hA* A• rkPA* kk*kA***AkkA**kk•Ast**-1•irkA CITY OF 1•UKWILA, WA 1RANSN3;T * A•* A** k* A * **%*4*•k•k;4 *A*•kk*A * *•A•k =:k' .k**:E **. *k.Ek••1**A4.*** * *** kA•*•!*A 1•CANSMIT Number R9700760 Amount: 860.50 05/07/98 17 :12 Payment Method: CHECK Notation :SA13.EY CORPORATIO mnlit: I3LH Permit No: ID98-0091 Type: DEVPERf4 DEVELOPMENT PERMIT Parcel Not 042304•-9182 Site Address: 2811 S 102 SP Total Fens 1 860.50 Total ALL Pmts: 1,416.90 Balance: .00 * *o1A *i * * * * ** * *A * * * ** * *+1 *.A* A *It'kl1•A ** * * k*4 *Afi * * **A k* *A *AA ** ** A *•A#* • Payment Account Code 000/322.100 000/386.904 Description BUI.LDING -• NONRES'. STATE 33UTLD :cNo SURCHAR[3E Amount 856:00 4.30 3 1 TRANSMI r Number: R9700731 Amount„ Permit. No: 098-0031 Type: Parcel No .0%42304 -91:12 Site .Address% 2811 S 102 ST *0 A4 L— d• k****** +� *fa * *•4k*ifi * *•A-A *IA# .lii *+ * + 4 k :l :� *:l *•a * ** • ** *'*. k * *. *. * CITY OF,•TUKW,ILA, WA TRANSMIT 4d *** *1 *k. ***, *4k * * ***4- *+ * * ** ***** * *:i*.k *�l * *•,4 * *4k :lksl * 4: ** 556.40 03/23./98. 16:35 Payment Method: CHECK Notation: TIMOTHY CULLTCKS Iriit: E'l.H DEVPEP.M DEVELOPMENT PERMIT Total Fees: 14416.440.' This Payment 556.40 Total ALL Pmts 556.49 . Balance: . 86:0.54 4. 1:t•4 h * * * **•k *•4.44*4 *• i, A.** k*k*F•4/:***** *41•h*:1k ***4“401A * *A• *: -*A—k . Account Code Description AmeUn , 000/345,830 . PLAN CHECK. - NUNRES 556.'40: COMMENTS: Type of Inspection: F i 4v 1 Addres S . J ) �'] L (�� I' - d-) /.r l (if .art e"."17.4, 9PP °1✓t11n,1 F - ' ( l\cJ 2.o6 730 - 6 , s7 9 '71 !' 1 H A --/-7'11 l.F/f (4* 2 ,L :L p 1 2-J /7)-1,e___, - , (;)--ii , e_ 3. * ( , .,." -$ a-x 4 ` • c.,. �-tle .� A Project: j- - ( v S Type of Inspection: F i 4v 1 Addres S . � ���c � Date called: ),-1 Special instructions: \Y". "'Ut' 9. 30 Q ' 9PP °1✓t11n,1 Date wanted: (� �r� ' -1 P P.m. Requester. l\cJ 2.o6 730 - 6 , s7 9 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 t ; - 18--oa PERMIT NO. (206)431 -3670 D Approved per applicable codes. Corrections required prior to approval. 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project_ X 000S t bM� 1 Type of Ins�ectio . - 9/4C R.(V'. A M T1 J S /02 5-r Date called: Special instructions: ' A Date t , 0 a.m: Requ r. lT a4fT Phone: INSPECTION RECORD Retain a copy with permit INSPECTIO O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: a $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Date: Receipt No: Pxr l obds Type o Inspectiqq: (4.4 .• . II 5 D . - -4 - C r Date called: Special instructions: t Date 27 9 a.m. P.m. Re ast r: 51 .Lf.L DtAX/c Phone: I E Approved per applicable codes. INSPECTION RECORD Retain a copy with permit- INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Q78-039( PERMIT NO. (206)431-3670 orrections required prior to approval. \ COMMENTS: 6,4"477:7- 40/ 7(.6 (14S 7 67/ C r , )) 4_ /Al&Oe-(75'td 0 • /4y,‘4 4- .../ ./A111111111111/47111111WAIIIIW 7 $47 10 REINSPECTION FEE REQUIRED. Prior to inspe tion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: ? Project: exo ps carnet � T ype ofitts ction: - : ... Addres, ` s a sr . I o Date called: 9 p i 11 C, Special instructions: Date wanted: cri. ��Qj Requester: � M 2(0 rte, 9 !�~ 'N Approved per applicable codes. INSPECTION RECORD � `�- , Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: ► Inspector: Date; 6,11 M I I $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Receipt No.: Date: Project; r ) J s, ( ft? LW/ 6 Type of inspection: FRAmmG Address: 7 J) S /62 ST Date called: 6 lb • "eV Special instructions: Date wanted: 6 //- P m. p.m. Requester: �FNN S Phone No.: 7107 ' co? 99 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspector; I - 0691 PERMIT NO. / Date -1/164 (206) 431 -3670 Corrections required prior to approval. COMMENTS: $42.00 REINSPECT6N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. f Receipt No.: Date: Project: gxp�u s (r.Nim . Type o inspecficin: AlAtG1 Address:. . )) /)9 s,7 Date called: (o' - n Special instructions: Date wanted: �0 _ �r -92 a.m. p.m. Requester DiNN Phone No.: 11 11 fir; J!q "trW+It' 'T t'''""7" INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 li 431 -3670 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Corrections required prior to approval.". COMMENTS: [ Inspector: Date: lul r $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: e_ XOWS CC349mathr47 Type of ipspec$on: I`fAfl Address: Zwww S /6Z "t' S i Date called: (n''?- c/g Date wanted: ` 3 - �, (9 MIN p.m. Special instructions: Requester: * ) ,�/t)i / .s I Phosf�jo� 110_7 - (02 v9 e4 . ` 041r.k YTi 3#ti **AikA.w;xdra . ".".*;.151:.xYf+. mnsooNian r ".". icepeniN xx+''ori ;: ;, s` • • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 ( /(Approved per applicable codes. COMMENTS: ti- Inspector: I I INSPECTION RECORD Retain a copy with permit I 1 1 . Date: 6, 98 - 0O9) PERMIT NO. (206) 431 -3670 Corrections required prior to approval. • $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: Project: •• x .C. J � Type of inspection: Ad s4 (l s [ 6 2 ._ ,.. Date called: 9 Special instructions: ,� O� t t fit�Y1/l ur a 5(1 i Iq Date wanted: • 5 _+ f " l �� P m Reque t ( '7 1 cc INSPECTION RECORD Retain a copy with permit I .,�N NO, CIT'' OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspector: I I c5 I PERMIT NO, (206) 431 -3670 Corrections required prior to approval. Date: _5 4 '40/ 17 $42.00 REINSPECT! • FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ID # I Test Date I Field Cure I Age Days 'Size Inch'Area Sq In' Weight Lbs 1 Max Load Lbs I Strength PS11 Set # 4256! 5/21/981 1 7! 6x121 28.271 01 1018401 36001 1 4257! 6/11/981 j 281 6x121 28.271 01 I 01 1 42581 6/11/981 j 281 6x121 28.271 01 I 01 1 FIELD I MATER[ ..J A.A.R. TESTING LABORATORY, INC. P.O. BOX 2523 Phone: (425) 881- 5812 REDMOND, WA 98073 FAX: (425) 881- 5441 CLIENT ADORES .Sabey Construction 101 Elliott Ave W #400 :Seattle, WA 98119 Copies To :) Date Mailed: 5/29/98 :ASTM :.C172, C1019;.C78 Urn er: 55 ' :98 -191 Riverfront Technical Park 2811 S. 102nd Tukwila D980091 sport Data Report Date 5/14/98 Inspection Performed!I •Location Inspection Type: Reinforced Concrete Footings at entry and generator fuel pad. Gri Location: Footings & S.O.G. Remark Resteel per plans and specs. Concrete placed by chute and vibrated. Material: Da Type of Material: Concrete Job Time: Air Temperature: 52 Material Temperature 69 Yield Unit Weight: 0 Slump Inches: 4 Slump Specification: 4 Air Percentage: Air Specification: 0 Supplier: Yards placed: Design (F'C) @ 28: Truck Number: Ticket Number: Job Mix? Mix Number: Cement Type: Cement: Lonestar Plant #: 45 14 3000 12 786419 No 3110 470 Coarse Aggregate: 2000 Coarse Aggregate: Sand: 1400 Fly Ash: Water: 245 Water Added: Air Entrain: 3.5 Admixture: Conformanc Conforming to Plan? Yes Explain if "No ": Inspector. A Wycoff Reviewer: Test' St rength> Tested Per: Conforms Y /N: Compressive Y /N: Yes ASTM C39 Cast Date: 5/14/98 Fracture Type: (If "Other ", than Cone.) Tested By: S Brown Reviewed By: M Jeong RECEIVED JUN - 4 1998 COMMUNITY DEVELOPMENT ALL REPORTS ARE CONSIDERED CONFIDENTIAL AND ARE THE PROPERTY OF THE CLIENT AND A.A.R. TESTING LABORATORY, INC. REPRODUCTION EXCEPT IN FULL, WITHOUT THE WRITTEN CONSENT OF A.A.R. TESTING LABORATORY, INC. IS STRICTLY FORBIDDEN. ( ,,, A.A.R. TESTING LABORATORY, INC. P.O. BOX 2523 Phone: (425) 881- 5812 REDMOND, WA 98073 FAX: (425) 881- 5441 ;Sabey Construction 101 Elliott Ave W #400 Seattle, WA 98119 .......:.................:....... ............................... Report Date: 5/14/98 Date Mailed: 5/22/98 Inspector: A. Wycoff Reviewer: M. Jeong Job Time: 12:00 Air Temperature: 50 tr sp ct :on P ` r o`r med DRILLED EPDXY REBAR DOWELS Per detail C -1, placed rebar in drilled, cleaned, and epoxied holes for tie -in to CMU wall. Hilti HY 150 utilized as specified. RECEIVED MAY 2 7 COMMUNITY DEVELOPMENT ALL REPORTS ARE CONSIDERED CONFIDENTIAL AND ARE THE PROPERTY OF THE CLIENT AND A.A.R. TESTING LABORATORY, INC. REPRODUCTION EXCEPT IN FULL, WITHOUT THE WRITTEN CONSENT OF A.A.R. TESTING LABORATORY, INC. IS STRICTLY, FORBIDDEN, NORTHWEST 3 z EXODUS II RIVERFRONT TECHNICAL PARK TENANT IMPROVEMENT STRUCTURAL CALCULATIONS MARCH 1998 ENW JOB NO. 96093008 DESIGN CRITERIA CODE: 1994 UBC WIND: 80 MPH, EXPOSURE B SEISMIC: ZONE 3 b1. 0011 . ENGINEERS NORTHWEST, INC. P.S. - STRUCTURAL ENGINEERS 6869 WOODLAWN AVENUE N.E.SEATTLE, WA 98115 (206) 525.7560 FAX (206) 522.6698 EXPIRES 11/12/ RECEI CITY O VED F TUKWILA MAR 2 3 1998 PERMIT CENThI Geo Engineers MEMORANDUM TO: Allen Tucker, Engineers Northwest fax no. 206/522.6698 FROM: Jack Tuttle DATE: a March 23, 199S FILE 0548 -015-00 SUBJECT: Pin Pile Length Allen, We have reviewed soil conditions in the area in which it is planned to install pin piles for partial support of new grade beams for Exodus in the Riverfront Technical Park. We understand that these will be constructed near the southwest corner of the building complex. Soil conditions in this area, as defined by the closest boring, consist of medium dense sand to a depth of 10 to 12 feet underlain by about 5 feet of soft silt. 'This stratum is, in turn, underlain by dense granular soils. We understand that it is planned to install 3 -inch diameter heavy -duty pipe piles with a desired design capacity of 5 kips each. To achieve this, we recommend that the piles be driven to a penetration of 5 feet into the underlying dense granular soils or to practical refusal, which ever is reached first. Based on the nearby boring log, this should result in pile lengths of about 20 to 25 feet in length. The contractor should be prepared to adjust pile lengths as necessary since the actual soil profile at the pile locations will likely vary from that at the nearby boring location. Also, changes in grade in the area since the boring was drilled would alter the indicated depths to the changes in soil type. ' Installation of the piles should be monitored to determine when the required penetration is reached. We can provide that service. Please call if you have any further questions or RECEIVED CITY OF .. MAR 2.3 1999 PERMIT CENTER ENGINEERS— NORTHWEST � NC. P.S. 6869 WOODLAWN AVE. N. E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560 - FAX # (206) 522-6698 1 R 4 0 et* tZ IL � co 3 / 1 1e JOB NO JOB NAME D ATE SUBJECT -I" 1' U Ifi SHEET ti OF BY 1 (1) N bpo5 et) O fi L PM w t- �2 W Lm (5T M tO OP/, Cl cola ca wl mra I otkv- $ (3 P KvI g ( 4 1 N E r 2 - 4 0 2 - I • 6/4 Ls fi vtgAzt s Lkf3 (4' (i4U J ii14 S /Wider D►V11 ( Wkt { , 4 1/2 qqo ml.) pico ' 61/ 'U‘it e2� w/ 4 4 @4 k--toer RECEIVED ' CITY OF TUKN«1A MAR 2 8 1998 PERMIT CENTI:h ENGINEERS — NORTHWEST INC. P.S. 6869 WOODLAWN AVE, N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560 - FAX # (206) 522 -6698 'JOB 6* NO tl(o1Dcts� 'Jos No. 1116 fi SUBJECT - �U� I, 1 � " e,Ra.),I W kw Ce = o,‘ z ) (Q--L 0-15 II 9 Icp-H.7 � y 16, i . P5 I c- F °41.- ((,1-) (I(.4 -) (I1e)= 11 -'1 1(0 I r I _I< '- Plc HP 1.1. cl �I w P ^ c Q I ps .c IQ 6 YMa1wt(wct 24 % \J (- � or3 (or7SY((01) - )3,13 Ci 41 SHEET I / OF' 13 BY fiV DATE CITY OF MAR 2 3 1998 PERMIT CENTER 4 23x' _ 1S5 NI =- 1 L ,, s/- ',, ii5 ►J 4-/ 14 = '1 lc -;- . kstuthi ¢ 4. 7 0/c/ ti 150 4 vx = I I I t te,= til oov t � s 1 , O( 0 Qt 9 k= 0,c) Li J ore 1 , ' -rb -= .41- (1v-)/1/(3a1 (1- 7 t9(?o + _ 1.31 ` o�2 X h 3=1Zq 1 Ire •' 'y (r�V.'166tort y3,17) j3, IG <<SI 2�z.�.1133 = _ / 17,g6 C b (G , e '7 a,<.ty fm fs K p k 2/(j *k) 1.33 *K 60 24000 1.780 0.00008 0.06054 33.7149 2.373 70 24000 2.390 0.00010 0.06993 29.2836 3.187 80 24000 3.082 0.00013 0.07913 25.9606 4.109 90 24000 3.850 0.00017 0.08815 23.3765 5.133 100 24000 4.693 0.00020 0.09699 21.3096 6.257 110 24000 5.607 0.00024 0.10566 19.6189 7.476 120 24000 6.590 0.00029 0.11417 18.2103 8.786 130 24000 7.639 0.00033 0.12252 17.0187 10.185 140 24000 8.751 0.00038 0.13071 15.9975 11.668 150 24000 9.925 0.00043 0.13876 15.1128 13.234 160 24000 11.158 0.00049 0.14665 14.3389 14.878 170 24000 12.449 0.00055 0.15440 13.6562 16.598 180 24000 13.794 0.00061 0.16201 13.0496 18.391 190 24000 15.192 0.00067 0.16949 12.5069 20.255 200 24000 16.641 0.00074 0.17683 12.0188 22.188 210 24000 18.139 0.00081 0.18404::;.; 11.5772 24.185 220 24000 19.685 0.00088 0.19113 11.1760 26.247 230 24000 21.277 0.00095 0.19810 10.8098 28.369 240 24000 22.914 0.00102 0.20495 10.4742 30.551 250 24000 24.593 0.00110 0.21168 10.1656 32.790 250 23000 25.363 0.00119 0.21887 9.8571 33.817 250 22000 26.182 0.00129 0.22656 9.5487 34.909 250 21000 27.055 0.00140 0.23482 9.2405 36.073 250 20000 27.988 0.00152 0.24370 8.9325 37.317 250 19000 28.987 0.00167 0.25328 8.6247 38.649 250 18000 30.059 0.00183 0.26364 8.3171 40.078 250 17000 31.212 0.00202 0.27488 8.0098 41.616 250 16000 32.456 0.00224 0.28713 7.7027 43.275 250 15000 33.802 0.00250 0.30052 7.3961 45.069 250 14000 35.262 0.00281 0.31522 7.0898 47.016 250 13000 36.852 0.00319 0.33143 6.7839 49.136 250 12000 38.588 0.00364 0.34940 6.4787 51.451 250 11000 40.492 0.00420 0.36943 6.1741 53.989 250 10000 42.587 0.00490 0.39189 5.8703 56.783 250 9000 44.904 0.00580 0.41727 5.5675 59.872 250 8000 47.475 0.00697 0.44615 5.2659 63.300 C ENGINEERS NORTHWEST,INC.P.S. �~ SHEET OF 6869 WOODLAWN AVE. N.E. (SUITE 205) SEATTLE, WA. 98115 IS MASONRY SPECIAL INSPECTED? CODE : - 1994 UBC INPUT (YES OR NO): :' NO . 1900' '+UNITS & fm = ; 1500! ! - ,'-: psi TYPE S MORTAR fs =[ jpsi Es = 29000000 psi Em= 750xfm= 1125000 psi n= 25.778 UBC -CMU Page 1 OF 2 fm =I 250 psi K = 12M /bd As = pbd j = 1 -k/3 RECEIVED CITY OF TUKWItA MAR 2 3 1998 PERMIT CENTER 3/16/98 CMUSTRES.XLS 250 250 250 250 7000 6000 5000 4000 50.344 53.558 57.176 61.265 0.00856 0.01079 0.01408 0.01928 0.47934 0.51786 0.56311 0.61702 4.9659 4.6678 4.3724 4.0807 67.125 71.411 76.235 81.686 250 ' 250 250 3000 2000 1000 65.894 71.128 76.984 0.02843 0.04770 0.10821 0.68235 0.76316 0.86567 3.7940 3.5148 3.2474 87.859 94.837 102.646 250 0 0.000 0.00000 0.00000 0.0000 0.000 250 0 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0 0 0 0 0 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000 0.0000 0.000 250 0.000 0.00000 0.00000.. ; 0.0000 0.000 250 0.000 . 0.00000 0.00000`" 0.0000 0.000 250 0 0.000 0.00000 0.00000 0.0000 0.000 250 0 0.000 0.00000 0.00000 0.0000 0.000 250 0 0.000 0.00000 , 0.00000 0.0000 0.000 l f C ENGINEERS NORTHWEST,INC.P.S. � 6869 WOODLAWN AVE. N.E. (SUITE 205) SEATTLE, WA. 98115 UBC -CMU Page 2 OF 2 SHEET 5 RECEIVE CITY OF TUK WI MAR 2 3 1998 PERMIT CENTER 3/16/98 CMUSTRES.XLS Q�I. n Q JOB No tvl "13C Jos NAME ,T SUBJECT T ENGINEERS - NORTHWEST INC. P.S. T S 6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560 - FAX # (206) 522-6698 `fiS - t 5t,l142 1I /9' w/ t21/ - (Oti NSF £ rola wfi= ti a eVd ) 1 1 t 40' kibi ti a PovT Pp-i/►t — 2Iem *-4;PT Wl " t•Ax31 xerbco I' 5;.)(1 r 91 rr 54, / 141 tf• 20 /5F DATE e/ / SHEET r } to OF BY l ) U' ° CITY OF MAR 2 3 1998 PERMIT CENTER ENGINEERS- NORTHWEST 5869 Woodlawn Ave NB Seattle,Washington 98115 po 100 JAMB DATA height (ft) width (in) thickness (in) add thickness (in) K factor parapet ht (ft) 17.50 ' 30.00 5.50 0.00 1.00 0.00 SPANDREL DATA thickness(in) offset (in. + outward) 5.50 0.00 OPENINGS LEFT width (ft) height (ft) RIGHT width (ft) height (ft) 9.0 9.0 6.0 14.5 MATERIAL DATA concrete (psi) rebar (psi) 3000 60000 LOADING DATA unfactored wind in (psi). 1 seismic... zone 0 ledger LL(plf)= 625 concentrated load LL(lbs)= 0 concentric load LL(plf)= 313 horiz load plf (+ inward): 0 REBAR DATA CONCRETE JAMB DESIGN (version 3.0) UBC 10 :51:11 Vertical 3 15 d= 4.00 Horizontal in in "2 / ft MOMENT AND DEFLECTION RESULTS + inward - outward Case Pu (kips) Mu (in -k) Phi+Mn (in -k) defl (in) LOAD CASES 1 8.6 -4.0 68.70 -0.05 2 8,6 -9.1 68.70 -0.08 3 r 8.6 -6.6 68.70 -0.07 4 12.5 -11.6 74.00 -0.09 5 12.5 -16.9 74.00 -0.13 6 10.1 -7.8 70.68 -0.07 7 19.8 -37.4 84.12 -0.18 1) .9DL + 1.3WL inward 2) .9DL + 1.3WL outward 3) .9DL + 1.43BQ 4) 1.05DL°+ 1.28LL + 1.28WL inward 5) 1.05DL + 1.28LL + 1.28WL outward 6) 1.05DL + 1.28LL + 1.4EQ 7) 1.4DL + 1.7LL INTERACTION CURVE DATA .7*Po .7 *Pbal .7 *Mbal .7 *Mn 94.2 27.5 94.7 56.8 NOTE Sheet 7 of s .EXODUS II TI NEW OPENING 0 out (psf)= 1.0 4°2"' 3041- `t it 1 L. 01545 (egsr srpd press (psf)= 0.0 import fact= 1.00 E3jt -4c- a ON(1) DL (plf)= 488 ecc (in)= 2.j s LL w /seismic= 0 Ft.c iz I-47M7 DL (lbs)= 0 ecc (in). 0.0 i LL w /seismic= 0 DL (plf) = 1436 1 LL w /seismic= 0 Rc 4 Qh11d pout t A9 $JE dist above floor(ft)= 0.0 CAN • 11!-Cc 0.13 2. 3015 0451' L k a F 1 2 JAM (Mg) Allow defl(in) Comments 1.40 case ok used interaction curve 1.40 case ok used interaction curve 1.40 case ok used interaction curve 1.40 case ok used interaction curve 1.40 case.ok used interaction curve 1.40 case'ok used interaction curve 1.40 case ok used interaction curve in cases 1), 2), 4), and 5) the LL used is 1/2 of the applied LL CITY OF T RECEIVED MAR 2 3 1998 PERMIT CENTER , '•'Jo ) e No 400130 Joe NAME >J�nOS 1 6869 WOODLAWN AVE. N. E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560 - FAX # (206) 522 -6698 DATE /1 SHEET b OF �Q, 43 SUBJECT__, (04191-1' B1(A (- VI CI NIt( OF °M t? BY I vu $ (' k ENGINEERS- NORTHWEST. TNC. P.S. 19;$ 7- 670/ I opt. (10 5 e loffo/c, pot mo towou.C N155" fi■Jci-; ores- (0194.)(afovic,) vie (po) i , l (7 o) Xl /1 2 114-(I,L)(11s) =3 4+pI RECEIVED CITY .OF.TUKWILq • MAR 2'3 1998 PERMIT CENTEF1 3• FPT NDRMAt. VENT / STAGE SOLO PREP MANHOLE 3" FPT SOLO.OPEWNG 4' FPT INSPECTION OPENNG 4- FPT PUMP 1' FPT TANK WATER ORAN WITH PLUG 4' FPT TAW GRAVITY. DRAW WTIH PLUG W8 X 31 3 0 n -n o 'w � tO C NOTES: L GENERAL: • PRODUCT: • CAPACITY: • STYLE: — UL — DEE TANK PROPRIETARY NOTICE: THIS PRINT AND THE NFORMATlON CONTAINED HEREIN IS PROPRETARY TO ACE TANK & EQUIPMENT CO. AND CAN NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR N PART, NOR V 6 . FPT EMERGENCY VENT IFT LUG 23' -9" OVERALL LEI}C 2. MATERIAL: 3 TESTING STEEL ASTM A36, OR EQUIVALENT. BEFORE COATING, BE Apt PRESSURE AT 3 -- 5 PSIG. 4. COATING: 4,000 GALLONS • SHELL: 3/16" PLA1 E • HEADS: 3/16" PLATE • DIKE FLOOR: 10 GAUGE • DIKE WALLS: 10 GAUGE • DIKE COWLIN 10 GAUGE USAGE NOTICE TANK IS INTENDED FOR STATIONARY INSTALLATION ONLY. MISUSE OF THIS 4' F P t CAUGC Z" FPT SOCK ,. -+-,, r •..v nrc nn . A n..a .r . r.�-. ,r - nnn q tr. 1 n t to t r•n, n es nr. cc • t ORA W1Nli TANIK) K r HON SEALABLE N t / NSPEC HON PORT • INTERIOR: BARE STEEL • EXTERIOR: RED SHOP COAT SCALE DRAWING IS NOT TO SCALE s. sHI PNC wECHr AND DAENSIC TANI< WILL • APPROXLAATE WEIGHT: 6.790 I TESTED • OVERALL LENG1I-1: 23' -9" • OVERALL WIDTH: 84" • OVERALL I.1EICI IT: 91" fl Mr=NRU-,NC r OFTAW 4" FP 1 MME DRAIN WITH PLUG I14" OVERALL WIDIII • �• TPI MOM OR ACE TANK & EQUIPMENT Co. N.O. eon WM AMA Cathie. WA 1•1011-00 30 S i s U 1 ✓ 1 C- u a I- I- 5- r DETAIL OF EXHAUST SCALE 1 =3 -o n 33 70 'cm 0 i { N .-nm m W cm ita m o 05.90 04.92 02.36 • 3 00 00.66 4 HOLES 00.54 4 HOLES EQ SP DETAIL OF SEPARATE CIRCUT WATER INLET. AND OUTLET MOUNTING FLANGE SCALE 1=3 CD CD LEFT SIDE VIEW Ototga. enptnconMnpq 'or sifter lydonnot nn of lluatrot'iane contained In thin flacons& we preliminary and here bait prepared fob the sole purpose u eiearulsn earl ereluallsn of Urge cancepta and /or pounds eta aplioutlsns. MI* document le not Intended to be relied upon for '' or epecroinienc of actual products or tnstaltatisr M C Yeclinary Co. (NC ammo no noposeitillty for the accuracy. ellablly, or ulnas of tie irdometIon contohad Aaron Ice any other purpose ae application. Thin aoceerd h fire property of NC. 1NM+oel 'Men pvnienan. mry akinia or Iro nical& to ethers /s en, toe other than thot for *rack a L intended i eepary mangled. • • loam. s1* OM =eo Owe Oft ma1aY smut* O01IOy na o ne WA 6101 • I* MOYO 11060 em: s sr • 1 ee arms coo rot ems JIM ones *sy•od Pam, lyAma Q1ao • ai/ sew r area I'. a 0 t U 0 U C C t r t DOOR OPEN —\ 19.25 17.50 15.25 15.25 17.50 19.25 • 32.30 0 NN. 01 CM gt 4 2111 """'‘ Irimunimis■Incal egitti 1,•■••■• ajws No. .0.1-1 . VIIIVIIMMIL IIl iI It 11Ir MLA' 0 1 TOP VIEW ■-• ReFtb (-I-en-era-4w 0 0 I": a— t' CO Design. engineering or ether intormaUon or aluetrouons contained in title document en) preliminary and hove been prepared for the sole purpose of domain:op oed valuation design tombola ond/or possible products or applications. Thie document Is not intended to be /Wed upon far designs or specifications et actual fweentsi or trot/3114m.. N C larcttinery Co. (WC) omens ne ~potability la the amatory. mitablity. er Mean el the infermetion conteincel heroin for any ether wpm* or appKccrfon. ilia document le the empathy et NC. ofeJtout +mitten penniselan. any awn, treeintiLlel Is Wham ter ow uce ether than (hot to which II lotended Ls ewes* prohitaled. 23.41 25.41 NV. sett MIL AIM WWI 1E1 MI, FOOL •0613 MU. I-I. lirn NO MK al 1 Oat OJNII .1111L VMS ' 25.41 23.41 21.41 saarnial IMMO ra) C 1 vs N C mammy cow it .••••• =IN MO MN &Mu fortom, I. 4 ro j --I Q -1 } 12. 1.21 REAR FACE OF CYLINDER BLOCK M Y c 1.75 TYP 1.75 TYP -11-.- 0.50 TYP 6 HOLE TERMINAL STRIP SCALE 1 =3 31.96 7.73 12.75 111112. 16.416.4.16 �rr en sar+rM fYL MON 1164. Y 2.r AOp(( 1104111 M! 016 1.16 sea: 1 1 4 1 nrO. 06e 4/611111646U I OM .HC I 0.116111 ante aaee.ssa. tD RIGHT SIDE VIEW -FRONT FACE OF C Naehirsry C.. ('1WC? asunu no reeponalb'.Zy for the accuracy. suitabNty. or fitness o• 011 itoneotlon contained nefein for any ether purpooe or appecaUon. T'I�s 0a b lee property of NC. Without written writvon, any oopyulg or trararritlol to others ter any use other than at for ■hich R i Intended if eapresay prohtoitea. RIM oacRIPTlON 01 - C0At11LPC Q awarst.n 02 - CD/ML11LPE OF ENGINE 03 - REAR ',cc Cu' C01JN00A D. WI - WATE0 O1AW 102 - MLR CO 137 - .IICRE7 MIAMI NMAIER 131 - VENT TO RAIATOR 130 - SCPOUAIt CIOCUR tUTLR i. ( 131 - SEPtMIE ORCUR MA1R 0. ( s•11 - CtECTIOCAL SLIMLY COMIIC:o 201 - Il3/4 STD WPC 111x• 202 - E19CCSS FUEL RETURN vuouttr six . 3/4 $PW MO 204 - FIJF1 • F7.TER Ro -0.117 22? - FUEL 000E 313 - nt ovum }• l 1/2 - TC1P 307 - OR fLLLR 12 30$ - 011 F1TEA RD -1.10 3011 - OL LE1 . CAGE 401 - AIR 9YLT . •402 - 100181121 403 - 1111EATIMI1 OUTLET .237' to .tsl oD. 120 - MINX NV U POWER 'ma _ c ui - It n Silra• GDImEetlo. sea - =rum OREPADI 713 - CUSTENED 110t1Ir1N1 Nom otoNe Alra OEM LEWIN a. 117911. • 1sIt13 LACK MOE RAw,Ofl Tf1PPOfri .ale 1 NOE= EA64 WOE Ira - 0.8010011 DUCT FIANCE WW1 1.1.13 eDl - WONG ETE e1S - trrUllG LOCATION tm - MONA& CRSTANCC halt k MAY 111E 110DOED AS WOVE DIMENS DOt 'WHOM JMROR11U'r J.1 LOCATED filar •.MLLE. 7F-F •vc OhRAtl. W CIN • 17386 00111041. 1104114 - 111.79 01CRU10nnmN - SLID [ [ I . 0 C G C L C V n C sou 'Pots L UMW N C lUCEINHRY C I 6 /ewer 179 M1. gtsw ■ 010 .1-111 r Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P i I i n g S t e e l._ S o i Is W o o d January 18, 2000 File: 98 -191 Kimberle Anderson President cc: Dave Larson City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Riverfront Technical Park Address: •_281-1 PermitNo.: ((D• :1:• 1. Reinforced concrete 2. Anchor bolt installation 3. Epoxy items Sincerely, A.A.R. TESTING LABORATORY, INC. Sabey Construction - Teresa A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING • NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspections were required and copies of those reports have already been sent. To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, UBC and related codes and /or verbal or written instructions from the Engineer of Record. Tel: (425) 881 -5812 Fax (425) 881 -5441 • 7126 180th Ave. NE • P.O. Box 2523 • Redmond, WA 98073 01/13/00 TUE 16:42 FAX 206 2? 0920 January 18, 2000 Bill Rambo City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila WA 98188 via FAX (206) 431 -3665 Re: Permit D98 -0091 For Exodus Communications at 2811 S 102 ° Street, Suite 160, Tukwila WA 98168 Mr. Rambo: Thank you for your help this morning with the different permits for our Exodus job. Attached, for your file, is a final letter for the special inspections for permit #D98-0091 per our phone conversation. We are working in getting the Fire Final inspection in order to call for the building final by January 21, 2000, as requested by your letter to Brent Bird of Sabey Corporation Arch Group on 1/11/2000. Warm Regards, SABEY CONSTRUCTION INC. Theresa Yee Construction Project Manager End: Geo Engineers letter dated 5/8/98; 2 pages AAR Testing Laboratory, Inc. letter dated 1/18/2000; 1 page illereSet. �r - e€ m Sabey Corporation B co e 730 -1e579 AN Equal Oppofl uL , Employe 101 BOOK Armin West. Suitt t00, Souk, WA 91119 (206) 211.200, (206) 211-0920 Yak RECbEl ED JAN 18 2000 CO ©EV AP NT 01/18/00 TUE 16 FAX 206 2 0920 Sabey Corporation I I CO 4 +. G P T1 1 h $' 'AAK I L3 I .L I d i L11LZ 11VLi. •.LiCJC�C� 1 �rL • Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P i l i n g S t e e l S o i l s W o o d Januari.18, 2000 File: 98-191 Dave Lemon City of Tukwila Building Deportment 8300 Southcenter Blvd. Tukwila, WA 98188 Project: Rlverfront Technical Park Address: 2811 S. 102' Permit No.: D980091 This is to advise you that special inspections are completed on the above referenced project. The following inspections were required and copies of those reports have already been sent. 1. Reinforced concrete 2. Anchor bolt Installation 3. Epoxy items To the best of our knowledge all work Inspected conformed to Tukwila Building Department approved plans, specifications, UBC and related codes andfor verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President cc: Sabey Construction Teresa A.A.R. TESTING LABORATORY, INC. ,14202 COMGTRUCTON II SPIOI1OM AND WTUNAL TIMM° NATIONALLY AociPTie LA/OIIATOat Tel: (425) 881 -5812 Fax (425) 881.5441 • 7126 180th Ave, NE • P.O, Box 2623 • Redmond 1 WA 98073 01/18/00 TUE 16:43 FAX 206 2r 0920 GeolVEngineers Sabey Construction, Inc. 101 Elliott Avenue West, Suite 400 Seattle, Washington 98119 Attention: Doug Gardner GeoEngineers, inc. 8410 154th Avenue N.E • Redmond, WA 98052 'I elephone (425) 861.6000 Fax (425) 861-6050 www.geoengineers,com . ,., ...., .... y.i.. ., . .., , ., •. •. . .. ,,.....,. Prhrtdd &r recycled oeoer, • Saber Corporation May 8, 1998 Report Pile Installation Loading Dock Modifications Exodus Building Riverfront Technical Park Seattle, Washington File No, 0548- 015 -01 1;003 Consulting Engineers and Geoscientiets Offices in Washington, Oregon, and Alaska The report presents the results of our monitoring of the installation of three 3 -inch diameter pipe piles at the Exodus Building in the Riverfront Technical Park in Seattle, Washington. The piles will support the outboard end of three short wing walls that will extend out from the exterior building wall that is also pile - supported. The piles were installed by McDowell Northwest Piledriving using a hydraulically- driven jackhammer mounted on a Bobcat tractor. One pile was located at the outer end of the excavation for each of the grade beams on which the walls will be supported. The inner ends of the grade beams will be tied into the exterior wall foundation. The piles were driven open - ended. The piles were numbered in the order drilled starting with the southernmost pile. Pile No. I was driven to a penetration of 22.5 below the base of the pile cap excavation. Pile No. 2 was driven to a penetration of 23.25 feet and Pile No. 3, to a penetration of 23.5 feet. A nominal refusal criterion for the hammer being used is a penetration of one inch or less for a 20- second period of driving. The final penetration results for the respective piles were: No. 1, 28 seconds per inch average for the final 6 inches of driving; No. 2, 40 seconds per inch average for the final 3 inches of driving; and No. 3, 23 seconds per inch average for the final 6 inches of driving. Based on the nearest boring, we anticipated that the required penetration would be in the range of 20 to 25 feet. i ■ lk 01/18/00 TUE 16:43 FAX 206 281 0920 Sabey Construction, J � May 8, 1998 Page 2 I Based on our observations or the pile driving, we conclude that the piles have b installed in accordance with our recommendations and will satisfactorily support the ' desi oading of 5 kips. If you have any questions about our observations, please call. JKT:cp p: 1000to099105480151tinaIs10548015I 1.doc GeoEnglaccrs Sabel' Corporation _. I�I004 Very truly yours, GeoEngineers, Inc. Jack K. Tuttl P.E. Principal January 11, 2000 Brent Bird Sabey Corporation Arch Group 101 Elliot Ave W Suite 330 Seattle WA 98119 RE: Permit Status D98 -0091 2811 S 102 St Suite 160 Dear Mr Bird In reviewing our current permit files, it appears that your permit for a generator installation issued on May 7, 1998, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician City of Tukwila aa,vvit, Xc: Permit File No. D98 -0091 Duane Griffin, Building Official Steven M.- Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax: 206.431.3665 ACTIVITY NUMBER: D98 -0091 DATE: 3 -24 -98 PROJECT NAME: EXODUS COMMUNICATIONS DEPARTMENT: Building Divis on Public Works \J 3 iw :4 4 DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete Q Incomplete LI Comments: TUES /THURS ROUTING: ?4in C.00VL Gar,� PLAN RE IEW /ROUTIN LIP At5 tea Fire rrevention "® r y &t al d-e)-1$ All�l Please Route ❑ APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions ❑ CORRECTION DETERMINATION: Approved E Approved with Conditions ❑ 1P10ROUTE.DOC 1/98 Routed by Staff (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: REVIEWERS INITIALS: m1 Planning Division rC o�'dinator DUE DATE: 3 -26 -98 Not Applicable LI No further Review Required DUE DATE: 4 -9 -98 • DATE: Not Approved (attach comments) ❑ DATE: DUE DATE. Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: Revision No. Date Received Staff Initials Staff Initials Date Issued Staff Initials Summary of Revision: I Received By: Summary of Revision: Received By: Received By: Revision No. Date Received Staff Initials Date Issued Staff Initials Staff Initials Summary of Revision: I I Received By: Revision No. Date Received Staff Initials Staff Initials Date Issued Staff Initials I I I I I Summary of Revision: Received By: Revision No. Date Received Staff Initials Date I Staff Issued I Initials I � Summary of Revision: Received By: PROJECT NAME: kxod( Site Address: 2 81 1 5 1O a ST Revision No. Summary of Revision: Date Received REVISION LOG Staff Initials Received By: PER NO:. 1 : - 00 Original Issue Date: 6'7- Date Issued (please print) (please print) (please print) 2' . Staff Initials I 110= cie 14h print) C CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL DATE: J' ' 6 PLAN CHECK/PERMIT NUMBER: p95-ooli E 'io r3 1Z T 77 , wv-12v4 . kWJ gc AEL 1-?0,± tMtt4. CONTACT PERSON: x7 J ( a(gAio PHONE: at 1 ? pro PROJECT NAME: PROJECT ADDRESS: REVISION SUMMARY: Ghu s r t vl 1 )114 , SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. RECEIVED C{ or UI(WII.A K MAY PERMIT CENTER SUBMITTED TO: Fire Department Review Control #D98 -0091 (512) Re: Exodus Communications - 2811 South 102nd Street Dear Sir: C City of Tukwila Fire Department March 27, 1998 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1- 1212.8) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 375-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 2 modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) Installation of above ground fuel tanks requires a separate permit, obtained at the fire department. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 Page number City of Tukwila John W Rants, Mayor Fire Department Thomas P Keefe, Fire Chief Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 i Fay (206) 575-4439 05/07/98 THU 15:58 FAX 206 281 0920 Sabey Construction Corp DEPAC. , VIENT OF LABOR AND INDUSTRIE. • . REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ' R I 'll: •(••. ' R:,i(�;,;L;� '(('i� '' . r� .:C�1';tiREOZ'STIiA'ION Ni3MBE CC O1 t ap FSA *1'41,PH 12%11/19'98 • r ;1$FFECTIVE: D ATE :.10 0 ` SEATTLE WA 9 813.9 725.052.000 (8/97) State of Washington County of 9 Deuu:h Anil Display Certificate I certify that this is a true and correct copy of possession of 1 x o . as of this date. Dated: 5ili v scaz ..r= sz aa1L CONNIE J. TAYLOR STATE OF WASHINGTON NOTARY —•-- PUBLIC MY COINlt$$L0N EMU 4 -1602 Title J My appointment exp±IIes 4'1 I (.J OO2- IIooi Vicinity Map BLDC- BLK'!' B'S BSMT CAB CRC CLR C_C- 6 C'_OS COL Corr CONT CC,ORD CPT :IM DN CR DU.G Abbreviations 4C Air Conditioning ACT Acoustical Ceiling Tile ADJ Ad Justable/Adjacent AL' Alternate .. Aluminum Angle oNCD Anodized 4P.PROX Approximately ARCH ArchlteC.ural At funding Blocxing Beam Bui.1, Standard Basement Cabinet Circulation Clear or Clearance Gelling • Center Line Cioset Contract Change Proposal Cc ur Concrete Construction Cothinu Contractor Coordinate Carpet Ceramic Tile Detail Diameter Dimension Dcua Door Drawl, EA ELEC ELEV c.O EXIST FM KtR FLUOR FOIL FT FMC PORN GA GALV GL GLB HCW HD DW HOR a HVAC INCA! NGL INeuL :NSTL JT Dcf-oo9/ RIVERFRONT TECHNICAL PARK Now East Ea, Elevation (Height) Electric Elevation (view) Elevator Equal Existing Finish Floor Fluorescent Furnished by Owner, Installed by Contractor Foot/Feet Furnished by Tenant, Installed by Contractor Furnish Furnishings Gauce Galvanized Glass /Glazing Gypsum Wall Board Hollow Core Wood Hard Hardware horizontal Hollow M.aal Heigh Heating Ventilation and Air Conditioning Inca Incandescent Irlude Insulation Installation Junction Box Joint KIT Kitchen LAM LF LTG MAT MAX MECH MED ME MFR MISC MID MIL North WA Not Applicable NIC Not in Contract NO Number NOM Nom Anal NON COMB Non Combustible NTS Not to Scale. OFNC- OFF ORIG PERT FERF F -LAM PLW'D FOL FR FT Laminate Lin. Feet Lighting Material Maximum Mechanical Medium Metianine Manufacturer Miscellaneous Mounted Ma feria VMetal Cn Center Opening Opposite Orgnal Permanent Perpendicular Plate Plastic Laminate Plywood Polished Pair Pa int C A SITE PLAN OHS Exiting ' I�iIIIli1nIILI , !!iliinlll!lill a ll IIII I!IllO III, Illii `;I Ill'I II �I ul lnlllnlll(�' f� . II'I III',IIIlilii. Itr� 1 'a �II_ 01111111wIIIIIIIIIIuI IIII.II l ° I— nn IIII!I1111II� IIJJ� II 'lllllll[± i ffl lll!illlil, +lll7 II 11 i j :V i I e — l { III � - -- III I ki - !I III!1!1 RO SCHED SEAL Soi S:M SO 57D S Te `tISP Radius Rbber Base Refrigerator Reinforcing Required Revision Room Rough Opening fEL Telephone Tempered -ER'IO Thermostat - (P Typical ;,`_R Varies •,GT vinyl Composition Tile VEN Veneer ✓ERN Vemtical l ! W' /0 LC LLD South Schedule Solid Core Wood Sealant Section .,neat Similar Sheet Metal Standard Steel Storage Suspended West/Watt/Width With Without Wallcovering Wood Area of Work General N U.S.P.S. FACILITY otes Occupancy CODES A. All work shall conform to the applicable building codes and ordinances. In case of any conflict where the methods or standards of Installation or the materials specified do not equal or exceed the requirements of the laws or ordinances, the laws or ordinances shall govern. Notify the Architect of all Conflicts. THE DRAWINGS AND SPECIFICATIONS A. Structural, plumbing mechanical, electrical and fire protection drawings are supplementary to these drawings. The Contractor shall coordinate the work of each consulting engineer with these drawings and the Tenant Improvement Specifications and shall notify the Architect of all discrepancies with a written request for c!arificatlon. Any work installed in conflict with these drawings or the Tenant Improvement Specifications shall be corrected by the Contractor at no expense to the Owner, Tenant or the Archt .. DIMENSIONS A. All Information shown on the drawings relative to existing conditions Is given as the best present knowledge but without guarantee of accuracy. The Contractor shall field verify existing conditions and dimensions and shall notify the Architect or any discrepancies or conditions adversely affecting the design prior to proceeding with the Item of work aFFected. B. Dimensions on the plans are typically to the finish face or partitions or to the center line of columns. C. Door and cased openings wit.ut location dimensions are to be four and one -half (4 V2') Inches from the faces of adjacent partition or centered between partitions. n. Locate partitions that are not dimensioned, flush and square with the existing str or on the centerline of a window mullion as shown. DO NOT SCALE DRAWINGS. A. The Contractor shall use dimensions shown on the drawings and actual Field measurements. Notify the Architect of any discrepancies found. ABBREVIATIONS A. Throug.ut the drawings are abbreviations which are in common use. The Ilst of abbreviations provided is not Intended to be complete or representative of conditions or mate•!a Is actually used on the project. The Architect will define the intent of any Ir. question. COORDINATION A. The General Contractor shall be responsible for the coordination and verification of the work of all trades to assure compliance with the drawings and specifications. D98 -0091 CANCELLED Project Data Project Name TENANT IMPROVeENTS FOR EXODUS CQ'tANICATICNS, NC. SUITE 60 S.F. of Work Area 3$45 eL (usable) NOTE: COMPUTER ROM IS ACCESSORY TO OFFICE USE AND THERERDPE UNOCCUPIED. EXITS REGUIF£D: 2 EXITS PROVIDED: 5 Design Codes 1994 tlBC, 1994 U PC, t 4II1C, F9S41FC, 1993 NEC 1994 WASHNGTC4 STATE ENERGY CODE MAC 51-0 1995 ULSSHIINGTON STATE REGULATIONS FOR BARRIER FREE FACILITIES OR DES. MAC 51 -30) Symbols ••' RIERDICE INDIVIDUAL DRAWINGS FOR SPECIFIC SYtWLS USED FOR THIS WORK •• Construction Plan HALL I3000 I Dot No. Sleet — Grid U. Detail Ildica Elevation Irdica Sect. No. Swum Idica Room Naas Room Identification Room iialber Revkbn 'ddicatee Building Data Address Building Area RIVER:ROW TECHNICAL PARK 2811 SOUTH 102nd STREET SEATTLE, WASHINGTC4 99168 Owner SABEY CORPORATION UM ELLIOTT AVENUE W, SUITE 330 SEATTLE, WASHNGTO4 98113 Tax Parcel Number Parking Provided 0423049186 -02 Construction Type TYPE 5N, FULLY SPRR1CLEF£D Legal Description ttttttttttto � LOT 2 THAT Paella! OF 314E 50.7THEASt QUARTER CF SECTION 4, TOIWB4IP 23 NORTH, RANGE 4 EAST, WM, N KNG COUNTY, WA8H13TON, DESCRIBED AS FOLLOWS: CCMENCNG AT THE S0.1THUEST CORNER CF GOVERB'IENT LOT II N SAID SECTION 4t THENCE ALONG THE SOUTH LINE OF SAID GOVERNMENT LOT IL SOUTH 89 22' 06' EAST, 95621 FEET* THENCE NORTH 14 45' 00 U.EST, 411D9 FEET 10 414 INTERSECTION WITH THE NORTH Lae OF THE SOUTH 460 FEET OF SAID GOVERNMENT LOT II OF SECTION 4 AND THE NORTHEASTERLY MAR31N OF FRIMARY STATE HIGHWAY NO. I AS ESTABLISHED BY KING co➢4T1' SUPEROR COURT CAUSE NO. 5290213 THENCE 4LOt•Kg SAID NORTHEASTERLY MAR3N, NORTH 14 45' 08' LEST, 68981 FEET TO THE SOUTHWESTERLY MARGIN OF TWAT 200 FOOT SEATTLE TRAN8MIS8104 LINE AS ESTABLISHED BY ORDINANCE NO. 82986 OF THE CITY CF SEATTLE, AS CONDEMNED N KING COUNTY SUPERIOR COURT CAUSE NO. 4695514 THENCE CONTINWNG ALONG SAID NCRR1EA8TERLY MARGIN, NORM 14 45' 08' WEST. 22.10 FEET TO A PONT OF SPIRAL. O0ATURE* THENCE CC4TR4UNG ALONG SAID NORTHEASTERLY MARGN AL80 A SPIRAL CURVE TO THE LEFT, THE CHOP OF WHICH BEARS NORTH B 01' 51" WEST, B2.94 FEET TO A PONT CF SIMPLE CURVATURE* THENCE CCNTNUNG ALOI84 SAID NORTHEASTERLY MAR'.s1N, NORTHWESTERLY 340.61 FEET ALONG THE ARC OF 4 NON- TANGENT CURVE TO THE LEFT, HAVNG A R401118 OF 391000 FEET, THE RADIUS POINT OF WHICH BEARS SCAM 14 01' 22' WEST, THR.^WH A CENTRAL ANGLE OF 04 55' 00'3 THENCE CONTINUING ALONG SAID NORTHEASTERLY MARGIN, NORTH II 24' 51' EAST, 3213 FEET TO 110 TRUE POINT OF BEGSNINGt4 THENCE CONTINAE NQRTN II 24' S1' EAST ALONG SAID NORTHEASTERLY TMAR5114. 6140 F:EET TO A FONT OF SIMPLE CURVE± THRICE 81 4TNUING ALcsiG SAID NORTHEASTERLY MARGIN, NORD- LESTER, 19154 FOt ALONG THE ARC OF A NON - TANGENT CURVE TO THE LEFT, HAVING A RADIUS CF 419000 FEET, THE RADIUS PONT OF MICA BEARS 50.1811 42'.. 23' (LEST, THROUGH A (ENTRAL ANGLE OF 02 33 294 T•@8E NORTH 21 10' EAST. 85118 FEET* THENCE NORTH 48 II' 59' EAST, 44251 FEET± THENCE SOUTH 41 52 . 02' EAST, 8821 FEET± THENCE sou. 48 05' 28'. WEST, 40681 FEET± THENCE NORTH 41 52' 51 WEST, 62141 FEET* THENCE SOUTH 48 II' 44' REST, 218.98 FEET MORE OR LESS TO THE PONT OF BEGWNNG. SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ❑ ELECTRICAL ❑ PLUMBING ❑ GAS PIPING ( : 4' OF TLIICIs'ILA f �...� 11:V,SI0i4 • Existing Partitions FIRE PROTECTION A. If necessaryprovide Fire protection at all penetration of fire rated elements as req'd. by the gavering authority. B. Contractor la responsible for modifications to the existing Pre Protection Systems as required by the work of htls Contract. C. Contractor shalt provide occupancy signs conforming with applicable codes requirements. D. Contractor shall provide exit signs In the type, number and location as shaven or as otherwise required by the 1863 Inspector. E. All exit doors shall be operable from the Inside without key or any special knowledge. F. Interior finishes shall not exceed a flame spread rating of 25 at exit corridors (wa118 4 ceilings) G. All modIficttons and/or expansion of the building Fire fire alarm system are to comply Washington State Building Code With ADA 4 was81:694 n state barrier free requirements To: visual and audible alarm signals. GENERAL CCISTRUCTIO4 A. The contractor shall Investigate and verify locations of structural mechanical and electrical elements and other existing conditions prior to 3:1111ng or cutting of slabs or structural members. Notify the Architect of any conflicts prior to beginning work B. The Contractor shall be responsible for providing all wa11 blocking as required for all wall and ceiling mounted Reins. C. All construction shall be stabilized against lateral movement In accordance with the requirements of the latest adopted edition of the MC In t. local jurisdiction. D. Ceiling heights, where Indicated, are from sub floor to bottom of 4ling grid or other finished surface. E. Mechanical, electrical, vertical transportation and sprinkler work shall be conducted unde separate permit. F. Certain work by General Contractor must be done during 'off hours' 15pm -8 am2 this work Includes: painting, carpet seaming, drain down of sprinkler system, 1010 hammering, coredrilling, power actuated fasteners etc. GENERAL FINISH NOBS A. There shall be no exposed pipe, conduit, duct, vents, etc. All such Imes shall be concealed or furred and finished, unless noted as exposed construction on drawings. B. Offset studs where required so that finish wall surfaces will be flush C. Provide galvanic Insulation between dissimilar metals. WALL FNISH NOTES A. All paint, wallcoverings and wall panels shall be applied in accordance with the manufacturer's specifications For the particular surface applied upon B. Samples of all flnlsh colors specified shall be submitted for approval by Architect prior to the commencement of work C. Flame spread ratings For Interior finish to be Class 3 or better. D. Paint I Is the general paint color unless ot.rwlse noted. FLOOR I: 88006 SF FLOOR 2: 88006 SF TOTAL: 11603 SF Occupancy B OFFICE SPACE 450 REGULAR STALLS 261 COMPACT STALLS 14 HANDICAP STALLS 1 HANDICAP VAN STALLS 126 TOTAL STALLS understand that the Plan Check cpp-sys pro sub to errors and omissions end approval of plans does not we.= the Violation of any adopted code Of txminola. MMosta of centractoes copy of Date Permit No EQUIPMENT Red: fire systems Orange: HVAC control Yellow: Gas Index of Drawings A00 A0) 402 SI ETD E2.0 GENERAL INFORMATION, PROJECT DATA GENERATOR F81. FLOOR PLAN, PARTIAL EXTERIOR ELEV. SHOLLER R1. FLOOR PLAN, SHOWIER ELEVATION, DETAILS FOINDATICN PLAN AND DETAILS SYMBOLS, ABBREVIATIONS, ONE - LINE 03406AH GENERATOR ROC1 DETAILS FLOOR PLAN DIAGRAMS Descri tion of Work INSTALLATION OF A GENERATOR N AN D(15T84G MECHANICAL ROOM. INSTALLATION OF A FUEL TAN: ADJACENT TO MECHANICAL R'I. WITH MODIFICATIONS TO AN EXISTING WALL TO ALLOW FOR VEr18RYs 4 EXHAUST. MODIFICATIONS OF 305TROOMS TO ALLOW FOR ADDITION OF 2 840.484 B. Pro sect Team ARC!- NTECT: SABEY CORP. ARCHITECTURE GROUP 101 ELLIOTT AVE. W 'J• )ITE 330 SEATTLE, ILIA 98119 TEL: C206)281-8100 CONTACT: BR14T BIRD GENERAL CONTRACTOR: SABEY CONSTRICTION 101 ELLIOTT AVE. W SUITE 330 SEATTLE, ±14 98119 TEL: (206) 2814100 CC4TACT: BERNIE MARTELL STRiUCTURAL ENGINEER ENGINEERS NORTNUEST, NC. Pb. 6869 I000LALLN AVE. NE. SEATTLE, WA 98115 TEL: (206) 525 -1560 CONTACT: ALLAN TUCKER TENANT: EXODUS COMMUNICATIONS, INC. 2811 So. 102±4 St Seattle, WA. 98108 CONTACT: TIM GULLICKSEN MECHANICAL ENGINEER: CONTRACTOR DESIGN BUILD ELECTRICAL ENGINEER: 5PARLNG 120 OLIVE WAY, SUITE 100 SEATTLE, WA. 98101 -1553 TEL: 1206/661-0525 CONTACT: WILLIAM GIJLLSTAD Location Plan First Level Plan ELECTRICAL/TELEPHONE NOTES A. The Electrical Contractor shall be responsible to maintain compliance with all codes and obtain all necess„y permits. 5. All deviations from c - ensioned locations must be approved by the Archtect. C. The Electrical Cant,. for shall verify the location of each core drill with the existing structure, piping, con:. .it, etc. and shall notifying the Architect of any conflicts or obstructions. All core 4.111 locations will be provided by the Architect. D. Any discrepancies be'usan existing conditions and Contract Documents s4uld be Called to the attention of the Architect E. Special heights are noted adjacent to the outlet. F. The Electrical Contrac or shall be responsible to maintain compliance with all ADA requirements for heights of fixtures and devices (I.e. switches, outlets, etc.). G. The Electrical Contractor shall label all elec outlets to panel circuit. H. See I6 for equipment'abeling requirement. MECHANICAL NOIE5 A. 814 HVAC system shall comply with all applicable codes. B. The Contractor shall verify sizes and locations of all open For mechanical equipment with Mechanical Drawings as we11 as shop drawings before proceeding with the work C. The Contractor shall provide balancing and reports. A. Where shown on drawer ±, Install Buildin Standard plumbin fixtures, Ills ectin9u1±her± and cabinets In accordance with GF� manufacturer's Instructlona. Areas of Work Tenant space - for Exodus Communications, Inc. Suite 160 EQUIPMENT LABELING A. Label all mechanical and electrical components (concealed at ceding) with appropriate colored dots on the (:ailing grid. Color coding system to be Sabey corp. std as .1140 OF TUItWILA Blue: HVAC units/ exhaust APPROVED Green: Water (shut err ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE 3(23)95 PERMIT SET NI drawinga and written meter. uppe ri Benim mnstitW the wdpfwwl wwd unputlbeM : of the eae Cor c'n wit u wme mq e M o the Sal awed s ere without � a s,. swear ampwrwawm: 45 50050t O0provert 5®(IDt 0 ®R, EKOdUS COININIMIOCATOONS RIVERFRONT TECHNICAL PARK Seattle, Washington DRAWING TnIE: COVERSHEET FILE: j: /arcvrvtrront /exodus /exedus2d PROJECT NUMBER: DRAWN BY: CC CHECKED BY: JJ2. APPROVED BY: • EXIST DR TO REMAIN 8' CMU WALL ID/ 5/8' THKX STUCCO Ens. TO MATCH EAST., PPR/v,a✓e Sv�v PAYER CAP FAST TND R EXIST CLG • GENERATOR Td'I EAST 1ST FL EX i 81DE WALK FINISH TO MATCH IXIST PARTIAL EXTERIOR ELEVATFONIWEST) SCALE: PATCH d P ANT IXIST. EAST RA LINE HOLES PROPOSED RAD ATOR f�SIZE BE TO FIEL hEA6UfaE IXIST L011VER MFILL EXIST OR. O GENERATOR ROOM /FUEL TANK SCALE: V4' -0' IXIST DONO. PNL EXIST P. JOINT EXIST WINDOWS PROPOSED EXHAUST PIPE FIELD PROvIDE ' DI CORE DRILL FIELD VERFT LOo CATION. EXTERIOR FINISHES TO MATCH EXIST. REFER if# ELEVATION FOR EXHAUST SILENCER PIPE LOCATION. RELOCATE SPRINKLERS AS REG/11 D. EDGE NON- BUILD Z CONDUIT, COORDINATE W/ ELECTRICAL EAST INTAKE IXIST GENERATOR EAST CURB EXIST CRAM LNG WEE/ DR GENERATOR ROOM 5/8' TTPE'X =GLL6 OvER b' MTE 20'G0. SEEDS • Ib' aaao 1 DERSIDE GP EXIST CLG EXSBT DOLLS. EGUIP. SEE ELEC. snc. MOTORIZED MTI,K£' DAMPER DdREb =MOVE EAST DR ENILAR'i XIS; ORYs 45 SHL11lL F%INDE SRLL DR _3• 5' SEE ETSVATrarc RELOCATED IXIST L FIX AS RE0D TTP. CORRIDOR RELOCATE D.S. AS SHOWN, ATTACH TO tN ERGWI' ND DRAINAGE e'OMJ WALL 13'H./ FINISH TO MATCH EXIST WALL TTP. PATCH SIDEWALK TO MATCH IXIST BRIDGE FDTN OVER HORIZONTAL CHILLER ROOM FLEL LINE, 14' -0q AFF. MM. FOR DETAIL LOADING DOCK * CONTROL 'JOINT NE EXIST SIDEWALK PROPOSED RIEL LINE PROPOSED 4000 GAL TANG S HT SLATED CHAIN LMC FENCE W/ PR 4' DR TAP. (PROVIDE PAD LOCKS, HEW CONC. PAVE FEHT PROPOSED 8 H. REWORDED W/ STUCCO PAINTED TO MAT EAST BLDG COLOR TYR DUST 4' PAINT STRIFES/ TTP. 14 D98 -0091 CANCELLED PEW PARALLEL PARCING SPACE EXTENT OF WORK • EOLLARD,S CITY TUKWILA APPR OVE,) MAY U 7 1993 D ARCHITECTURE GROUP CONSULTANTS REVISIONS 4,7,115m .u� JOHN W ISSUE DATE 3/23/98 PERMIT SET NI drawings aM wMbn =WWI appearing herein mnNWte tln original and unq,blbM1ed work of the So. Caporadan and Ns .awn may net be duplkated. Peed or Aldo. ....Won Won cor .d al tM 9abq CamaraMm. G1 teaming gmtre euap®w? Sou EKOO RIVERFRONT TECHNICAL PARK Seattle, Washington DRAWING TITLE: PARTIAL FL PLANS ELEVATIONS FILE: J: /arcl✓rvtfront /exodus /exodus2a PROJECT NUMBER: DRAWN BY: CC CHECKED BY: JUA. APPROVED BY: DRAWING NUMBER: GTV OFETUHDINItq 40 • MAR 2 .s 1gg8 PERMIT CENTER D98 -0091 CANCELLED r F V4'wl' -0' CERAMIC TILE EV CT BASE EXIST CPT Ivor MIS I FLOOR PLAN SCALE: INTERIOR ELEVATION Eaelgrika 1 I SHOWER RM R. PLAN Nome, I. F'RONDE CERAMIC TILE AT CEILING OVER E4ICUE2 45E4 ONLY OTHER AREA TO BE GM PAINTED, COLOR TO BE SHERWIN WILLIAMS • 1353.'OLD IVORY CERAMIC TILE AT WALL Ql $HOLLER AREA ONLY, ALL OTHER WALL FINISH TO BE PAINTED W' SHERUIN WILLIAMS • 1361 'DECOR WHITE'. BASE TO BE CERAMIC TILE: DAL -TILE D -4B REECE 4X4, BULLNOSE AT EDGER AND CORNERS 2. PROVIDE EXHAUST FAN /TIE TO EXIST RESTROOM EXHAUST FAN RELOCATE EXIST CLG LIGHT TO CTR OF ROOM FRONDE 241.3614 MIRROR 34' TO SOT. OF MIRROR BOBRICK 8465.2436 REPLACE EXIST DR TO OBE 3' DR REUSE • MODIFY EXIST LOCKSET AS REDID, PROVIDE RIBBER REDUCER AT ENTRY EXIST SERVICE DR TO REMAIN TIP. REMOVE EXIST PARTITION /DASHED LINE) EXIST PARTITION TO REMAIN TYP. REMOVE EXIST DR FRAME FOLDING CHAIR NEW FL DRAIN TIE TO EXIST SD. TIP. NEW PARTITION FINISH TO MATCH EXIST(TYPJ 1/4 TEMPERED GL Skx1ER Er1CLOSW¢/ 3' DR TIP. DUSC44RIEHE, INC. .00) 348 - 8080.12 Ea. GRAB BAR !BRADLEY GRAB BAR W' SANITARY SAFETY FINISH, CONCEALED MCWTMGI PROVIDE INTERMEDIATE SUPPORT / BLOCKING AT WALL AS REDID PROVIDE MIL CLOSETS AS SHOEN TROLL MAN, FRAME MODEL B W' 36kRk20'W / 4' BASE PROVIDE KEYED LOCK OR EO.) P LAM COLOR TO BE SELECTED RELOCATE EXIST DP. AS AHOLN PROVIDE COLD WATER SUPPLY, POWER =RECT TO ADJACENT SMC DRAM REPATCH WALL/CAP PLUMBING PIPES CITY OF TUKWIIA APPROVED MAY 0 7 19133 MAR 2 3 1998 PERMIT CENTER ARCHITECTURE GROUP CONSULTANTS 3533 , 1 / /liJ iHN W. A STALE Oi WASXI '.115��� REVISIONS ISSUE DATE 3/23)98 PERMIT SET NI dmninpn and wMan mated appearing heroin amedtute tke arNYWI and unpuakkod work of the Saba, Corporation and tM pima may not be dunkated. used or Ms.* Mama Wm nlWn cwmt of Me Sob, Corporation. 188 tome e®glv ®a ®aw®E4 9©u RIVERFRONT TECHNICAL PARK Seattle, Washington DRAWING TITLE SHIIA. PLR PLAN INTERIOR ELEV. DETAILS FILE: J: /arch'-vtfront /exodus /exodus2a PROJECT NUMBER: DRAWN BY: CC CHECKED BY: JU.L APPROVED EY: N RECEIVED 40.2 III ••11 CITY OF TUKW > - - -- > EXIST. OPNG. -I I - ` --- I > <� I SAWCUT NEW OPNG. ___ 14_ 6" ABOVE SLA9 __ Z_ STT O 1 51RCNGBACK� EIIST. OPNG.I r--- 1 i I -- >G I R }'x1' -0 "xis -0" INSIDE II 4'"4 - - - - HILT KBII . GTR. O c0 HONJOINT & 9" VERT . N J T.S. 6x44: IXIOPNG. :i: A I 1 vJ I I / \I V V EIST. OPNG. Imo— -- -- I >< — I EX_ 1ST. FLOOR?7 _1_ -____ - -- - -- PREVIO 1 R:Y 1 )( I: 9 / \ II L/ Vr \I I DqB 2- #5 VERT.) E.F.) 15 14 i3 1 11 10 V O 8 7 © OS T L p2 O 1 O I I I I I I I I I I CMU 4 0 24 "oc HORIZ. EMBED 4 }" w/ HILTI HY -150 ADHESIVE) 1ST. PANEL SECTION A -1 = 1 _ 0 . NOTE WELD TS 6x HO RIZ. REINF. PLAN DETAIL C -1 FOUNDATION PLAN b) N.T.S. ADM SECTION B -1 3 "0 SCHEDULE 40 STEEL PIPE DRIVEN TO REFUSAL CRITERIA PER GEOTECH ENGINEER (2 CAPACITY MIN.) LOCATE 1' -0" FROM END OF GRADE BM. (SPLICE SECTIONS w /12" LEEVE COUPLERS) MB s #6 DWLS 10" INTO EXIST GRADE BM. w /HILTI HY150 ADHESIVE). SECTION D -1 = 1 ._ 0 .. O NOT DOWEL NEW SLAB INTO EXIST. WALL RGX R /3 -FIILTI KBII' (EMBED 44 ") A R " NON- SHRINK r 1" R EF SIDE WALL w -i H THRU BOLT BEARING R 6x 4x } T.S. (INSTALL PRIOR TO REMOVING ENTIRE OPNG.) 1 2 CL EXIST. JOINT r EXIST. TD pETAILL E -1 PARTIALLY Y IN INF1 l D PER ARCH. 6" CURB PER ARCH. J CONTRACTOR TO VERIFY THAT -6" 5' -let 5' -0' .IST. CONCRETE PANEL HAS NOT BEEN PREVIOUSLY ALTERED IN. OR SAWCUT. 26' -8" r 8" CMU SCREEN 'NALL 6" CONC. SLAB ON GRADE REINE. w/ # ® 18 EA WAY ®SLAB Ct REF. DATUM PER ARCH. EXIST. 5k" F.C. WALL ON COAT. 2 R. WIDE CONC. GRADE BR. w/ TIMBER PILES ® 10' -0 ° roc EXIST. 7 } STRUCT. SLAB H 13 CL JOINT EXIST. WEST ELEVATION EXIST. P.C. PANEL JOINT SECTION E -1 D98 =00 CANCELLED =T. 91 PER ARCH. O GENERATOR SKID 1 " STIFF. R EA SIDE ®EA SUPPORT m THADED ROD EMB ED 4}") w /HILTI HY -150 ADHESIVE 24'0 HILTI KB II O 3 -0 "o /c (EMBED 4}") 13 may. �P 4,0 AOV PER ARCH. DETAIL I D -1 I R TYP. NOTE; ® NEW GENERATOR PLACE 4- W8x31x8 -0" BMS. CENTERED AT EACH PAIR OF SUPPORTS SEE DETAIL F -1 PARTIAL FOUNDATION PLAN (VIEWED LOOKING NORTH) SECTION F -1 ISOLATOR WELDED TO W8 W8 x 31 x 0 B' -O" NP. CEN ON SUPPORT 4" NON - SHRINK GROUT EXIST. 7 } STRUCT. SLAB GENERAL NOTES THE FOLLOWING NOTES APPLY UNLESS NOTED OTHERWISE CODE: UNIFORM BUILDING CODE -- 1994 EDITION - ASTM'S LATEST EDITION LIVE LOADS WIND.....80 MPH, EXPOSURE B SEISMIC ZONE.....3 V = ZIC 117,;r x 1 x 2.75 x W/6 = FOUNDATION IN ACCORDANCE WITH SOILS REPORT BY GEO ENGINEERS TO BE VERIFIED. SOILS ENGINEER WILL INSPECT THE INSTALLATION OF THE PILING AND WILL MAKE FINAL RECOMMENDATIONS ON EMBEDMENT AFTER REVIEWING FILL SUBMIT PILING RECORDS TO ENGINEERS NORTHWEST AND BUILDING DEPARTMENT. PREPARE SITE PER SOILS ENGINEER'S RECOMMENDATIONS. CAST Fc = 3000 PSI FOR ALL CAST-IN-PLACE-CONCRETE. ULTIMATE STRENGTH DESIGN METHOD USED. CONCRETE MAY BE PROPORTIONED ON THE BASIS OF FIELD EXPERIENCE AND TRIAL MIXTURES OR BY WATER- CEMENT RATIO AS DESCRIBED IN CODE. SUBMIT MIX DESIGN AND DATA AS REQUIRED FOR EACH METHOD. IF WATER -CEMENT RATIO METHOD IS USED MAXIMUM WATER -CEMENT RATIO BY WEIGHT IS .58 FOR NONNR- ENTRAINED AND .46 FOR AIR - ENTRAINED. MIXING AND PLACING OF ALL CONCRETE AND SELECTION OF MATERIALS SHALL BE IN ACCORDANCE WITH THE UBC AND ACI CODE 318. PROPORTION AGGREGATE TO CEMENT TO PRODUCE A DENSE WORKABLE MIX WITH 4" MAXIMUM SLUMP WHICH CAN BE PLACED WRHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. SEE SPECIFICATIONS FOR ADMIXTURES. PROVIDE 52 + 11/22 TOTAL AIR CONTENT FOR FLAT WORK CONCRETE EXPOSED TO FREEZING ANO THAWING EXPOSURES. LIMIT WATER -CEMENT RATIO TO •45 AND USE TYPE V CEMENT WHERE CONCRETE IS EXPOSED TO SOIL CONTAINING WATER SOLUBLE SULFATE IN EXCESS OF .22. ADD NO WATER AT SITE. WATER REDUCING OR LASNCIZING ADMIXTURES MAY BE USED TO INCREASE WORKABILITY WITHOUT INCREASING WATER - CEMENT RATIO OF Ni MIX SUBMITTAL :TEE SPECIFICATIONS FOR CURING 3/4" CHAMFER ALL CONCRETE CONCRETE EDGES UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRA'k1NGS. REINFORCING STEEL USE DEFORMED CONCRETE REINFORCING STEEL CONFORMING WITH ASTM A615, GRADE 60 (Ty= 60,000 psi). LAP CONTINUOUS REINFORCING BARS 36 BAR DIAMETERS, 2' -0" MINIMUM, UNLESS NOTED OTHERWISE PROVIDE CORNER BARS (2' -0" BEND) FOR ALL HORIZONTAL REINFORCEMENT. DETAIL STEEL IN ACCORDANCE WITH "AC! MANUAL OF STANDARD PRACTICE OF DETAILING REINFORCED CONCRETE STRUCTURES ". WELDED WIRE FABRIC (WWF) TO CONFORM WITH ASTM A185. REINFORCING HOOKS TO COMPLY WITH STANDARD ACI HOOKS EXCEPT STIRRUPS AND TIES SHALL HAVE 135 DEGREE ACI SEISMIC HOOKS. COVER TO REINFORCEMENT: CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH................... ...3 FORMED SURFACES EXPOSED TO EARTH OR WEATHER .................. #6 AND GER.... # AND SMALLER.., -1/2 NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND SLABS, WALLS, JOISTS ......................14 AND LARGER. 1-1/2 #11 AND SMALLER......3 /4 EEAMS, COLUMNS PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS.......L...1 -1/2 REINFORCING STEEL WELDING USE ASTM 4706 GRADE 60 (Ty = 60,000 psi) FOR ANY REINFORCING THAT IS TO BE WELDED. FOLLOW PROCEDURES OF ANSI /Weds D1.4 -92, ,"STRUCTURAL WELDING CODE - REINFORCING STEEL ". USE E80XX LOW HYDROGEN ELECTRODES CONFORMING TO ANSI /AWS A5.1 OR A5.5. DO NOT WELD REINFORCING IF TEMPERATURE IS ;BELOW 32 DEGREES FAHRENHEIT. MAINTAIN A MINIMUM PREHEAT AND INTERPASS TEMPERATURE OF 50 DEGREES FAHRENHEIT FOR N0. 7 THROUGH NO.11 BARS. DO NOT WELD N0. 14 AND NO.18 BARS. DO NOT WELD WITHIN 3- INCHES. OF BENDS. LET BARS COOL NATURALLY TO AMBIENT TEMPERATURE AFOER.WELDING; 00 NOT QUENCH. USE WABO CERTIFIED WELDERS. PROVIDE SPECIAL INSPECTION'S PER CODE. SUBMIT MILL CERTIFICATES. STRUCTURAL, SQL ALL WORK IN ACCORDANCE WITH "ALSO SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" , AND THE "CODE OF STANDARD PRACTICE ". STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING STANDARDS: STRUCTUPJYL STEEL ASTM 0 -36 (Fy= 36,000 PSI TUBE SHAPES ASTM A -500, GRADE B (Fy= 46,000 PSI WELDHEAD S .LOS ASTM A -108 (Fy =50,000 PSI) ANCHOR BOLTS ASTM A -307 HIGH STRENGTN BOLTS ASTM A -325 PROVIDE MINIMUM EMBEDMENT FOR ANCHOR BOLTS PER UBC TABLE 19E FOR CONCRETE AND UBC TAB. 21N FOR MASONRY; .UNLESS SHOWN OTHERWISE. ALL WELDING TO CONFORM WITH AWS D1.1 STRUCTURAL WELDING CODE - STEEL ". WELDS NOT SPECIFIED SHALL BE 3/16" CONTINUOUS FILLET MINIMUM. ALL WELDS BY WABO CERTIFIED WELDERS. USE FRESH 70XX ELECTRODES FOR MANUAL SHIELDED METAL -ARC WELDING OR EQUAL ELECTRODES FOR OTHER WELDING PROCESSES. WELDHEAD STUDS (WHS) ARE TO BE MACHINE WELDED WRH PROPER EQUIPMENT AS R-LUiRED EY MANUFACTURER CONCRETE EXPANSION ANCHOLIS - "HILTI KWIK BOLTS" - INSTALL- IN ACCORDANCE WITH ICBO REPORT NO.4627 . MASONRY ANCHORS - "HILTI SLEEVE ANCHORS' - INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. COORDINATE WORK WITH JOIST MANUFACTURER. SEE SPECIFICATIONS FOR ITEMS TO B._ GALVANIZED. MASONRY REINFORCED HOLLOW UNIT MASONRY. SPECIAL INSPECTION NOT REQUIRED, F'm =1500 PSI. USE GRADE "N" HOLLOW LOAD- BEARING CONCRETE MASONRY UNITS CONFORMING TO UBC STD. 21 -4. USE TYPO S MORTAR BY VOLUME: ONE PART PORTLAND CEMENT, 1/4 TO 1/2 PARTS HYDRATED LIME AND DAMP LOOSE AGGREGATE NOT LESS THAN 2 -1/4 NOR MORE THAN 3 TIMES THE SUM OF THE VOLUME OF CEMENT AND LIME USED. FILL ALL CELLS CONTAINING REINFORCING AND WHERE NOTED WITH GROUT - MIN. STRENGTH, 2000 PSI. USE COARSE GROUT ONLY WHEN CLEAR CELL EXCEEDS 3 "X3 ". CLEANOUTS REQ'D. FOR GROUT POURS OVER 5' -0 ". LAP NP. MASONRY WALL REINFORCING 48 BAR DIAMETERS. ALL CONNECTIONS AND BOLTS SHOWN EMBEDDED IN MASONRY ARE TO BE INSTALLED BY THE MASONS DURING THE CONSTRUCTION Or THE WALL OR PIER. PROVIDE CORNER BARS TO MATCH ALL HORIZONTAL REINFORCING. ALL MASONRY TO BE RUNNING BOND LAY -UP. REBAR DOWEL INSTALLATION DRILL HOLES FOR DOWELS IN ACCORDANCE WITH GROUT MANUFACTURERS RECOMMENDATIONS. BLOW HOLE CLEAN WITH OIL FREE COMPRESSED AIR. FILL DOWN HOLES WITH A MEASURED AMOUNT OF HILTI HY -150. INSERT REBAR AND SECURE UNTIL GROUT HAS REACHED ITS INITIAL CURE. ALL WORK SHALL BE BY PERSONNEL EXPERIENCED IN THE USE OF THIS PRODUCT, AND IN ACCORDANCE WITH ICBO REPORT N0. 5193. INSPECTIONS INSPECTIONS ARE TO BE PER UBC CHAPTER 17 AND ARE TO BE BY AN INDEPENDENT TESTING LAB. INSPECT. PILE INSTALLATION. TAKE CONCRETE CYUNDERS AS REQUIRED. BY CODE, VERIFY SLUMP, STRENGTH, AIR CONTENT, PLACEMENT OF CONNECTIONS; AND ANCHOR BOLTS. REINFORCING: VERIFY THAT ALL REINFORCING IS PLACED IN ACCORDANCE WITH APPROVED PLANS. CHECK FOR REQUIRED COVER, SIZE, GRADE, AND SPACING: CONC. EXPANSION & COPY OF ICBO REPORT FOR ANCHORS OR ADHESIVE SYSTEM USED MUST MASONRY ANCHORS & BE AVAILABLE AT JOB SITE. VERIFY ANCHORS OR ADHESIVE SYSTEM DRILLED IN DOWI_U^: INSTALLATION IS IN ACCORDANCE WITH REPORT. WELDING: INSPECT ALL FIELD WELDING INCLUDING WELDING OF REINFORCING STEEL VERIFY CERTIFICATION OF WELDERS. CONTRACTOR SHALL PAY FOR REWELDING AND REINSPECTION OF ALL WELDS NOT MEETING SPECS. INSPECTOR SHALL NOTIFY STRUCTURAL ENGINEER OF WELDS NOT MEETING SPECS. ALL FULL PENETRATION WELDS SHALL HAVE ULTRASONIC OR RADIOGRAPHIC INSPECTION. FOUNDATION: CONCRETE SHOP DRAWINGS SUBMIT 2 SETS 0- PRINTS AND 1 SET OF REPRODUCIBLE SEPIAS OF SHOP DRAWINGS TO ENGINEER FOR ROA. AFTER CONTRACTOR HAS REVIEWED & STAMPED FOR COMPLIANCE AND PRIOR TO FABRICATION FOR: GLU -LAMS, FLOOR JOISTS, STRUCTURAL STEEL. SPECIAL CONDITIONS CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENCIINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. NOTE TO MECHANICAL AND ELECTRICAL TRADES CONTRACTOR SHALL SUBMIT PLANS SHOWING LOCATION, LOAD AND ANCHORAGE OF ALL HANGERS SUPPORTING ANY MECHANICAL, ELECTRICAL PLUMBING OR SPRINKLER LOADS IN EXCESS OF 50 POUNDS. ANY ROOF MOUNTED EQUIPMENT SHALL BE INCLUDED IN THESE PLANS AND SHALL. SHOW LOADS AND LOCATIONS. THESE SHALL BE SUBMITTED TO ENGINEERS NORTHWEST FOR APPROVAL PRIOR TO INSTALLATION OF ANY OF THIS EQUIPMENT. ALL DETAILS OF CONNECTIONS TO THE STRUCTURE FOR EQUIPMENT SHALL BE BY THE SUPPLIER OF THAT EQUIPMENT. IF THE BUILDING DEPARTMENT REQUIRES A SUBMITTAL REGARDING CITY OF TUKWILA THE DESIGN OF THESE DETAILS, IT WILL BE THE RESPONSIBILITY OF THE EQUIPMENT .APIROVED I r ...': me Plan Chc:'' r.sore and omissions e... p - not WW01160 le Noloticn. c, ;. code at ufils Rweyt oI coot c.. ; c1 appM6Wd pM5 Da to Permit No. FILE COPY 1 98 f RECEIVEp CITY OF TUxWILA MAO I t 1940 PERMIT CENTER • EY CORPORATION ARCHITECTURE GROUP CONSULTANTS REVISIONS ISSUE DATE AS NOTED 5 -12 -98 III droving, and when material apeonny heroin camdtute the original rod. unpublished work of the Sabey Comomllon and the roams may not be' used or disclosed MM. Me urn.n meson of the sows Coriemotbn. Riverfront Technical Park EXODUS II TENANT IMPROVEMENT DRAWING TTTLE FOUNDATION PLAN AND DETAILS MO) NO19 FILE: RT PLOT: 3 -23 -98 BIJiLUTFJG D '"'-''''t PROJECT NUMBER: 96093.008 DRAWN BY: S.V. CHECKED BY: A. TUCKER APPROVED BY: DRAWING NUMBER: S i PLOTTED: