Loading...
HomeMy WebLinkAboutPermit D98-0104 - LYONS SAFETY - STORAGE RACKD98 -0104 1109 Andover Pk. W. Lyon's Safety City of Tukwila ( Parcel No: 352304 -9110 Address: 1109 ANDOVER PK W Suite No: Location: Category: AWSE Type: DEVPERM Zoning: CM Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: TUKWILA Wetlands: Contractor License No: NORTHSCO24DT. Permit Center Authorized Signature: Signature:__ (-Zz �_1 1�'L DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: South: .0 East: .0 West: Sewer: TUKWILA Slopes: N Streams: Date: End Time: Fi l l (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 D98 -0104 ISSUED 04/28/1998 10/25/1998 1994 SPRINKLERS /AFA .0 OCCUPANT LYON'S SAFETY 1109 ANDOVER PK W, TUKWILA WA•98188 OWNER BOEING WILLIAM E JR 1325'4TH.AVE SUITE 1940, SEATTLE WA 98101 CONTACT TIM EARLY Phone: 20 575 -1671 22257 WEST VALLEY HY, KENT WA 98032 CONTRACTOR .NORTHERN STEEL COMPANY Phone: - 575 -1671 .22257 WEST VALLEY HY, KENT WA 98032 )1/4***************************************************************.**************** )1/4***************************************************************.**************** Permit Description: INSTALL PALLET STORAGE RACK. ************************************ * * * * *•k ** * * * * *•k * * * * * ** ** * *•k ** Construction Valuation: 5 .00 te) PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separa Eng. Appr: Curb Cut /Access /Sidewalk /CSS: .Fire .Loop Hydrant:: No: Flood Control Zone: Hauling: Start Time: Land.. Altering: Cut: Landscape Irrigation: Moving. Oversized Load: Start Time: End Time.:: Sanitary Side Sewer: No: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: Public: '* k• k************ k****************• k****** k* ********* ***. * * * * *•k * * *•k * *•k * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: 5 519.71 .******** * ** * * * * * * ** * * * * * * * * * * * * ** * * * * * tl **k*******•.*** * * * * * * * * * * *•k * * * * * * * * * * *•k * * * ** Size(in): .00 ' IXL4:(�(.tx I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. f/24/7g Print Name:___ _ iETaj-- This permit shall become null and void if the work is not commenced within • 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 1109 ANDOVER PK W Suite: Tenant: Type: DEVPERM Parcel #: 352304 -9110 CITY OF TUKWILA Permit No: D98 -0104 Status: ISSUED Applied: 04/01/1998 Issued 04/28/1998 4 •4 •4 •k '4' •4 •k •k * •4.4 k k •4 4 •4 •4 •k * * * •4 •4 'k '4 4 •k •,4 :4 * •4 •k k •4 * 'k 'k 4 :k •k •4 •k * * •4 '4 •4 •4 A• 4 4 •4 •k '4 •k •k :k •k 4 •k 4 'k k •k '4 '4 'k k * •k ' 4 k •4 •k '4 Per•nri:t Conditions: 1. No changes will be made to the plans unless: approved by the Archi tect or Engineer and i`fding,Division 2. All perm nspect ion. records; and .aa plans sh�a11 be, available at the jo s.:i,.te prior to the... ..40. o an y' con- ,�•. , rs true tion. Thes�e;;.adcscument, pare to be : ma intai'nY avail - able until f 10a'1,5111 sper ion pprov.al is gi-an t ed k, r All construction to ,be ,, o "ne .in w,yth a`p�+trioved plans and _r, requirernents the s gniforirr Bu' ic.iny ode �;i1X94 Edition). as -'amende.'d;, Unif.ormMe'chanical..Coce "'(.1994. E�iit.ion) and Washin'gt State Eti'ergy, 'code f1994 Edition). 4 Va i i d ity of Pe`rmi t. The .issuance ,;of• a per Mtt approva plans. ;, pe "cifscations. and computations she]1' :riot.tip con strued . to. be 'a .' pe'rmit for, 'e r an approva of, any violation of any of 'the provistans of the code or iof',an,y other oryfin'ance of the:. juris'dichoir: No permit pre'scirintg . give aauth.or,i ty` to violate -or- 'cancel the . provisions ?: of ,,this • code shat T be. va l Project Name/Tenant: Val}uv of Construction: ,, ..����� Proposed use: 71 Retail ❑ Restaurant 71 Multi-family t1!'Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /Universit 71 Other Will there be a change of use? ❑ yes IFS n� o Site Addr s: / _ /L� i"1',1GN4�/.z� Z/� id, � � r ,�_ Will there be rack storage? ayes ❑ no City State /Zip: �r .�w, � I �B��S Tax Parcel Number 1 1 6 ?7�Jr'? (-1'f 62//0 Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets PrAperty Owner : / Phone: Street Address: 7 City State /Zip: Fax #: Contractor Phone: Street Address: /J ` 2 2 2 s" 7 Al.esYl 7# i City State /Zip: 7 9SD,.J z - Fax #: / Architect: G J /!/ arr -€ Phone: Street Address: City State /Zip: Fax #: • Engineer: ry , / Phone: Street Address: City State /Zip: Fax #: Contact Person: G Ar/ — Ao�� e� 'Dir:..+ r�r Phone: .Z to � S .S 7 � l0 7 / �/ � /11 Street Address: �,L // 2 2 2 5 7 �' l� J r 7�1 . /c t) y / City State /Zip: i9 y`F'o 32. Fax #: 2c) e, A S' c5P SO 4 Description of work to be done: / Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family L Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other ,, ..����� Proposed use: 71 Retail ❑ Restaurant 71 Multi-family t1!'Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /Universit 71 Other Will there be a change of use? ❑ yes IFS n� o If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ayes ❑ no Existing fire protection features: IE7 sprinklers a fire alarm ❑ none ❑ other (specify) Building Square Feet: 2 0,100 existing Area of Construction: (sq. ft.) /S. DOCK .. - Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Commercial / Multi - Family Tenant Improvement / Alteration Permit Application - z C/TY OF4' "'tWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 CTPERMIT.DOC 1 /29/97 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Number :} APPLICANT'REQUEST FOR PUBLIC; WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) El Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault)lf: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt It: Size(s): ❑ Water Meter /Permanent it Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Sewer Main Extension ❑ Water Main Extension 0 Deduct ❑ Flood Control Zone ❑ Hauling El Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application pied( Date application expir Appl taken by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER OR AUTHORIZES 'AGENT: Signature: r- Date: ' Print name: iy / Phone: — b7/ , , 1 ' Fax #: " S`S 8 Cab Address 2 Z 6 L�r t' c c 4/ / ,u: City/ e to /Zit �, -ems 8 ©3 Z. ALL COMMERCIAL/MULTI-FAIV Y TENANT IMPROVEMENT /ALT': ' ION PERMIT APPLICATIONS MUS`I :E SUBMITTED WITH THE FOLL • ING: . • AL• L' DRAW1 1G$. Td BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, ''STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN - BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ � Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer,' licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit: this Permitapplication;gnci obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND / AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1 /29/97 A++a+*^+�a^+�+^+*aa�+*+��*^a�^++*+^+�+*��+^*aa*�+�a�++*+« A* ~ � � CITY OFTUKNILA, NA � � TRANSMIT': . +++++*^*44+A+«***+**+^i+A*^++++++ TRANSMIT Number:' R9700755 Amount: � � 316.75 04/28/98 10:59 Payment Method: CHECK Notation: NORTHEHNSTEEL " "Injt: BLH . \ Permit No: D98-0104 Type: DEVPEKM DEVELOPMENT PERMIT Parcel No: 332304_3110 Site Addrjeso: 1109 ANDOVER PK W ' Total Fees: 519.71 316.75 Total ALL Pmts: 519.71 Balance: ,00 i++*++,,+*+a4,4a** *+*++aA*A+*++��++^+*/+*1+^A,+**^*+*A4aa*A*A***+ Account Code Dec,criptiun Amount. 000/322.100 BU3LDIN0 - NOMRES 312.25 000/386..904 STAyE BUILDING SURCHARGE / 4.50 This Payment -----~-~_--------~~~-----^____--^--~.'��_-------~~--~~-_-._�~`-_' • 1543 04/29 97�7` 'TOTAL ��i�°75� ^� � '-- ' ' . > 4kat> 1* k*• k• k *lc lc* ** *A•. *k- 1 *•kk:4o-1 *.l*;'c •k •k:1•k.:t:t?► k:kAka:*:k:k* *A . TRANSMIT CITY OF TUK.WILA, WA * kA• h 4: 4> 4A• 4 icA** A1,* A: kkAAhklA #lk **Ak*it4k *Akk kk•k•.l•k k•skAhA **** *A *:l *k TRANSMIT Number: P9700737..Amount: 202.96 04/01./.98.16. :06 Payment Method: CHECK Notation: NORTHERN $TEE L Init: I3LH Permit No: D98--0104 Typn I)EVPERM DEVELOPMENT PERMIT Parcel No: 352304-9110 S i t e Addross: 1109 ANDOVER PK W . Total Fees: .519.71 This Payment 202:96 Total AIL Pmts: 20.2 „96 Balance: 316.75 ** A* i .I.•Ak*AA•A /.•AfiiA•k• *•A tlA *. A >Av ". *A * A,;*A b *AAA * *A kAkl1***A *A d* Account Code I)eacr i pt i on. 000/345.830 PLAN. CHECK -7 NONE EB • Amount. 202.96 06.11 04/01,7719 TOTAL ?02q6: (........ Project: . ` e9 � s � � Type of inspection: ( J /O9 Q6/, / Date called: Special instructions: Date wanted: 6 y 7 8 1;) Requester: T >/ - a �-� 1 INSPECTION NO. Inspector: I Receipt No.: INSPECTION RECOR `° Retain a copy with per CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 X Approved per applicable codes( COMMENTS: f PAike- PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: .41 r ! F $42.06 REINSPECTION (,IEEE R OUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: ht /!:5 4 Typ ff insam:.,.L _ Address 6q ^ _ l � V W Date called: 1 - i s Special instructions: Date wanted: m. Requester: Phone No.: INSPECTION RECOR4-- Retain a copy with perm.. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. I I ►+ PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: Inspector: Date: qp,C/ 1" I $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: No_j_z_46.17 Addres /0 /� Date calle Special instructions: Date wanted: a.m. /e V r'. — ' /r l --(21/1&/ /f e ____P____Ael, f"- C �/5f .i A Projec . Type of inspecti n: Addres /0 /� Date calle Special instructions: Date wanted: a.m. Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD ( Retain a copy with permit Approved per applicable codes. Inspector: PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date : A40n 41 717 1 $42.00 REINSPECTIOI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ___J Date: Receipt No.: CITY'' OF TUKV Notice Building Division •=' ^. 6300 Sputhcenter Bo eVard, Suite 100 & Tukwila; WA 98188; O rder } 431k3670 Telepi�'one: x (206) 4 ALL PERSONS ARE HEREBY ORDERED TO IMMEDIATELY STOP WORK # SW P7" (9 V ,PERTAINING TO CONSTRUCTION, MiTERATIONS OR REPAIRS /---) ,. r THIS ORDER IS ISSUED BECAUSE /Y ii r t..( f " "" ? ' 1 / 1 °✓"' o POSTED .6 AM PM L / - / 7.19 677 BY % . Y /l - -r»• Name/Title ON THESE PREMISES AT WARNING: Failure to comply with this Notice and Order shall subject the offender to a civil penalty of up to $100.00 for each of the first five days that the violation exists and up to $500.00 for each subsequent day that the violation exists. ( . Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM A A 1..e,A AfTWaa.,;..4ri•A • City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief TURWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name L- QAA>) Address \\V X Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Permit No. T.F.D. Form F.P. 85 Suite # Ca 0))(6 Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575•404 • Fax. (206) 5754439 BY 13776 DATA 3- y! r PROJECT LYONS SA SHEET NO. 1 OF 7 CHKD. BY 5re5e. ?04-U.K RACIes P2 Lyonlr sAr-z�ry /., TUkc c IJ A ulc 1994 14A, * 22. .y . it _ . FP/?. 017-0140/ S cs V = (c/, „) 1.1 r. 0.30 ( €r/e3) ►,J C= 2.7s gw = (o T A-p4SIJ• Dig - 5R44-ceQ PRArm -j 1 = 8 C ce v IT - m6"1-17 1 USE- 100 1' 18 Gs'/t /Z4c.1/C .4.76'!419 L o. h9 DATE l.a ,M e”+ 1f.” .3(2.. 4.1.b = l.Ggl @ 163. s, :s Ni = 214, Ra k . u . .. ... G d • + 4 - 3 ' 4 . V . . ._.. S65 2 : (..16 _k .. T_ _.GI V 0 +7. ii5 / cot.. k 4444 2. = rv. i Sk bolo Co+w Pe_ a .IZ. RI it- ID? &ALA.( T)rti .4 'IN A :. I3lfric 13M E . ruKI41C4 1414 JOB NO. 984 H o. 2lo v a . z��.l�•�, aisg CAA-x.) PA:_?.I`• 'f L t 12660 '9 if 4 10/w i l,V EXPIRES 7/14/ 9 8 • •-• • u 2 - Lz * 412 4 4-zLTs KB -!E 6 3 " beo) &Atst TA Z. 0.2 4 (0 0 , %-1 1; = 1.4$ k VA = 2 • I . 24 M. O A ' tS '' * 3 .ZL. . t r SP "c+ - 1 1 . 4 S 7.t.; Pt* 4-`2.1 w 171+Aur grtc 4. 1.0 6Rt 14 (11 Saver . = 0.$41 .:.__ )nMc ki-1 145.64 O' i.0 .lc. k..c,: / ..,.CITY. CF Tu rk > 1PR_..0...11998 b4/01 L PERMIT CENTER 4.►. - ... BY ATX DAT I - It PROJECT SHEET NO. 4 " OF CHKD. BY DATE JOB NO. 042. , c.A.8 Soa.. ,, (Awl" Po, = /Z 9/ *. /3A'-$t- Q-A-1& l 3 /, " S C't 414 5rEer X•ble t 4-x 6, 4 D. 4g1 . -W. 4 /3 I. — ek 13 1 4 se A 42 • 4? Z• Kb) C■ P. tzr 17/.. 3 xottip -6 o, 37 " oA 4 Aci-u44- Vel -rw 51.48 av S 72 Stk.! MA 34loc) Coi4c, ,414.61.3 z 127 psi' .762, vrif t2 that:7 los.e az 2a.+ -t 24,14-V" s e a- ‘2.4 61 A 4 , 30.24Z /t 6.027 pi" _ PA U,. bZ 1.04VGIT Int peg- fre-f- tz17. S. r- 1J 4.0/z 4. •/," z. A It I / S P.3ZS iC 14ENC• • I: 54 k f: . 14 F3 C. 0. 2..7 t o. 32 k . 6 1.7 t k 114 OS 11. k C2- 10- . 4 34- J& 34- _ 1..60-i () AeSOntAJ 40" 44.c.tr CR./ rt RECEIVED CITY .OF TUKWILA % gPA1.4 (.4V 4o e7447 14 tr . 10.43 4- , q APR 0 1.1998 kt. > (7%i 2 N 1p. 1.3 w • PERMIT CENTER- ( ) 16 /2 Z4. k. --,r la. 2 SA OA, BY 13 1 7 - DAL 3/0g PROJECT ' SHEET NO. 3 OF CHKD. BY DATE JOB NO. 'Mt he 594. 21 - Z.PSJZ k.y /.a y 48 kra .Y Li- C44 y 3.243 AL J = • o0 3 ?3 . I , }t ri LV ,9 �+ P 241AI It Z 3i.8 ? =7 D. 3 Lf /t s P. 7 . 124 SPA- LgF 4s4 Coo : 13.4i sk > ' M - 30.7S k" =7 bx z 2G. 9S k /k 4,1% ; 0. 57 ," . . ok . �l « := • 47 a i SPAd S Ld F 4-37 two N4 = /3, S 1 k z 34,1 k .. . 27. 6k kc.r _.. at 4.6 wtro A- 97- 5i9 FJ kip/ fR- 6,2k(.)17+( 6,dA I.1 • la, � t� oR _ (34.9) .__ z 13,4$ !� - e& A__ ` e z 5L+.10/004.4)/ o.al 0.1G° Liao = D. Fly' —!4 > 3 ,4 LAd p f = . loS t ' (c . J. o Ps 6,is leo s 7. // : l 1. OS" �T -ri : / Z. 08 ko ;o (kL/1 )0. 92. sr (e4 -ocs (Tee f 33,11 r..:. 3101 G : Q't. 54,64 k.„' .7 P..4: ZD• 4,J O 0.10 ,4NG C. %s c>K �i Fa •1 (4K /' 0 '"A ID.) ONO P444- 1 - Z 4 ( 0 . 4 - 6 ) a- 1.1,S ,k. G /..3,7 RECEIVED_ _.__... CITY Of TUKWILq APR 0 1 1998 PERMIll CENTER • 61. o.q! GAGE T in X in I x in S in r in I y in Sy Ina r in AREA in 16 .060 I .4189 .0893 .1190 .6234 .0379 . ^ 4. 5 . v 6 .. . 2297 14 I .075 I .4261 .1081 I .1440 .6169 .0464 .0564 I .4043 .2839 12 ( .105 .4405 ( .1418 I .1890 .6041 .0621 .0767 I .3999 .3885 10 .125 .4551 .1706 .2275 .5914 I .0764 .0960 .3956 .4878 10 9 8 _10 7 J Q o 6 X a 5 W a N 4 o0 3 J z 2 1 PREPARED BY P. TINGEY DATE 10MAY91 BRACING SECTION PROPERTIES NO. I DATE H= 1 1/2 } I YL T 5= 1 1/4 I I I I I I 1 II I I 1 1 I 14 G a �� 101111\ \;�111•1•n 0111111111111 I 1111•••=\ \•1111•MIS5111•111111• I • 1111111•111a•• • 11\► ■111111■1110�•11•11 w11RRU URURURnUUUUU iir_ 11111111111111=1111•11111111111111111111111111 • 1 I I II I I I I I munummmuumns mum -me IIII 0 20 30 40 50 60 LENGTH IN INCHES DRAWING NO. R -S REVISION 13.3 14.6 10.6 9.31 7.98 6.65 5.32 3.99 2.66 1.33 0 0 cn 0 J Z Q 0 -0 a W CD a o Z < J N 0 U_ = VI Z W U, RECEIVED QITY OF TUKWILA 70 80 APR 0 .1 1998 PERMIT CENTER E lf IF BEAM SECTION PROPERTIES PREPARED BY P.S. Ting ey DRAWING NO. R -1 DATE 14 SEP.'93 REVISION NO. DATE BY MODEL F = C p C Ix in S in r x in Iy in S y in ry in AREA 1n LB020 .075 2 .75 .2928 .274 .716 .6033 .4133 1.031 .5718 L8030 .075 3 .75 .7604 .4659 1.026 .8786 .6054 1.103 .7218 L9035 .075 3.5 .75 1.1854 .6313 1.223 .9475 .6712 1.093 .7922 LBC30 .075 3 .75 1.3689 .8817 .184 .9403 .6099 .9820 .975 L8C35 3.5 .75 1.951 1.0473 1.363 .9705 .6159 .9614 1.050 _.075 LBC40 .075 4 1.5 2.6631 1.2769 1.538 1.105 .7096 .9921 1.125 LBC45 .075 4.5 1.5 3.5073 1.5033 1.709 1.2449 .8025 1.018 1.200 LBC50 .075 5 1.5 4.6437 1.7655 1.908 1.3902 .9029 1.044 1.275 LBC55 .075 5.5 1.5 5.7951 2.0453 2.071 1.5269 .9975 1.238 1.350 LBC55A .105 5.5 1.5 7.7919 2.7571 2.038 2.0719 1.3498 1.051 1.876 LBC60A .105 6 1.5 9.587 3.1421 2.192 2.1979 1.4517 1.049 1.995 LBF356 .060 3.5 1.5 1.2039 .6277 1.274 .7576 .5097 1.011 .7414 L8 F354 .075 3.5 1.5 1.4739 .7699 1.267 .9284 .6242 1.006 .9181 LBF404 .075 4 1.5 2.0512 .9481 1.437 1.0635 .7190 1.035 .9931 LBF454 .075 4.5 1.5 2.7526 1.141 1.605 1.1984 .8143 1.059 1.0681 LBF453 .090 4.5 1.5 3.2119 1.333 1.598 1.3985 .9497 1.054 1.2578 5 CITY OF APR 0 1 1998 PERMIT CENTER $ P oA40 3• P/r-I IMT IteA itf monlcrl7 C.4P4C /7 PiN 112A-Tegiork. !1 C /Dlo W /T l5 = 44 As,. oLOmi-i inar eg 'AL /J AS71 ,4 510 G+¢ 1.4n4 F S o ks~: w vrt4 Fu : 6 5 ks,.' F7,..1 tj,Almere. a 11 /3Z Ref AREA ' TT Dz/ 4 • O. ° 9 Z 8 I u s ,� p,a = o, 4- Fo r--a. p$)146 N N I ANI re r - F = 40 ks.i r4,Q M 1171e /2- 9 4- P 0/ (o.07S) K :C / J 03. s7) 7.. //. 8 51.1 rnAregikL lag ).0 F. FDA CoL LI, N vr) kreo, M. P P1$1 Si{ n :. oo28 , o.444 r. � k 1.6 }S 2t41c- e,4 LM 15 oR LAI 20 (t. .07s `) (11J32) A D. 07,C 4.5 = I _ /c gHlwc D) LM 30 `t: o. /05 : C"► /3Z).s o./os < 6r _ 2,3 LIS E P, : !. f? r� I _ 0.84 AT/0 P _ 0.ol Aili' Pia 0.86 x 2,75 4- x P.7S = /o. I S 3614 MA : Jo.1 81t 4/3 13,57 k a w 0 1 1 A F i t , : s S k s,' Lv i /4.1 ) 4z Ice,: 6a 4S tS: go, 4LN 6, 15 dpri. LA zo k 7,U W s,Tr20( .$ iei40 geteet n1s c' 1 i i o 6-1/3.2)6'1°S)(55") % 1.91 k CITY FETUKW /LA /, 0 3 k ...*‘9,01 gi2 LAI 30 APR 0 1 1998 PER IT CENTER I M, I O/' G M ?. CTv i 46 4S /mss,. i I �1A 13.5 kk Ln/ 3o ` 4e. -'! 44" . L �' COLUMN SECTION PROPERTIES PREPARED BY P.s.Tingey DRAWING NO. • R DATE 16 JAN.'92 REVISION NO. DATE BY A 15APR'93 PST MODEL + c cl B in X in I in Sx in r in I y in Sy in ry in AREA in LM 15 .075 3 1.625 .689 .582 .388 1.156 .205 .219 .686 .411 LM20 .075 3 3 1.435 1.023 .682 1.263 .872 .557 1.165 .618 LM30 .105 3 3 1.45 1.373 .915 1.249 1.164 .752 1.15 .859 LM20/15 .° 0 3 4.625 2.607 1.78 1.187 1.231 2.577 .988 1.481 1.143 LM20 /20'0 075 3 6 2.714 2.222 1.481 1.268 4.701 1.431 1.845 1.349 LM30/15.1 a75 3 4.625 2.789 2.126 1.417 1.23 3.052 1.094 1.473 1.384 LM30/20 ' 3 6 2.951 2.568 1.712 1.262 5.45 1.788 1.838 1.590 LM 3 6 2.707 2.98 1.986 1.256 6.387 1.94 1.839 1.875 J .87 - .53 LM B PRIMARY COLUMN PUNCHED u. x BACK -UP COLUMN UNPUNCHED x CITY OFETUKWILA LM / APR 0 1 1998 PERMIT CENTER 7/ 7 ACTIVITY NUMBER: PROJECT NAME: LYON'S SAFETY DEPARTMENT: Building Division Awc. Public Wrks S �, n TUES /THURS ROUTING: \PR•ROUTE.DOC 1 /98 • PLAN V��� N(Dpi, D98 -0104 DATE: 4 -1 -98 Fie Pr ion Plan ` g Division ❑ Structural Permit Coordinator die DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 4 -2 -98 Complete Incomplete ❑ Not Applicable n Comments: Please Route n No further Review Required Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 4 -16 -98 Approved n Approved with Conditions Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: City of Tukwila Fire Department Fire Department. Review Control #D98 -0104 (510) April 3, 1998 Re: Lyon's Safety - 1109 Andover Park West, Building #E Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all. times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Thomas P. Keefe, Fire Chief 3. Hose racks must remain unobstructed to allow the rack to swing freely. (UFC 1001.7.3) 4. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) John W. Rants, Mayor 6. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 3 Thomas P. Keefe, Fire Chief 7. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 8. Warehouses designed for high -piled stock shall establish and maintain aisleways of not less the 44 inches to provide access to all exits and fire department access doors. (UFC 8101.6.3) 9. The storage of idle (un -used) pallets is limited to six feet in height by the Uniform Fire Code. If storage quantity in excess of six feet in height is required, outdoor storage must be utilized. (UFC article 81) (NFPA 231) 10. The critical storage height for high -piled combustible stock in closely packed piles is 12 feet. (UFC 9.110) Storage above 12 feet may necessitate increasing the sprinkler density to extra hazard and adding smoke removal capabilities. (UFC 8101) (NFPA 231) High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) 11. To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) 12. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number' . 4 Yours truly, cc: TFD file ncd Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) 13. Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 231C, 3-2.3) 14. A permit is required to use any building or portion thereof exceeding 500 square feet for high-piled combustible storage. (UFC 105.8-h.3, article 81) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. The Tukwila Fire Prevention Bureau Thomas P. Keefe, Fire Chief John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57.54404 • Fax (206) 5754439 .. ............___..„.„..„",".. I:625.052-1m I(';;97) 1:43.0[2''.AN AN INDUSTRIE •z; • ,/:;.; REGISTERED AS PROVIDED. BY:•"'LAW:•:' AS CONST :(1611!I'. GENERAL "1' ; • n'• - • • REGIST. • #' • :Exp.: DATE CO24DT 09/01/1998 • EFFECTIVE. DATE . 1 . :*;:" . .`: '7.03/30/1998 NORTHERN STEEL COMPANY 22257 W VALLEY HWY KENT WA 98032 I:623.03241M) (8,97) 1)et.tcli And I)isplay Certificate REGISTERED AS PROVIDED BY LAW A91 CONST CONT GENERAL REGIST. # EXP. DATE CCO1 NORTHSCO24DT 09/01/1998 EFFECTIVE DATE 03/30/1998 NORTHERN STEEL COMPANY 22257 WA/ALLEY HWY. KENT WA 98032 Signature Is D Issued Iv DEPARTMENT OF LAB D OR AN INDUSTRIES = , - • •:- ' • .... • ' ' . . . • 1 • . .. , . . . • . . . . . . . . ., . , • .. .. • . . . ' ' . . • . . . . . ' ' ' • • • Please ROMOVC And Sign Identification Card Before Placing In Shipping & Receiving 14' -0" HIGH FRAME / FOR HEATER CLEARANCE i 10 -0" Office Shell CHOS 1.5 , E DI. 75 LONG ALL RACKS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. Roil Door ttLIILD(NG DI \Ina.) L IRES 7/14/, _��'DO�E {� PARK F � r�x WE BUILDING E To 1 Plan an FILE COPY I I 09 L T�U I�WI:LA WA � .188 Illy r EWER 3/a8/9 s� and orN.esions en.; p _a not authorlee Ohe violation or c. , APPROVED . P � pis c2`zv9 G ' ar . _d code or p of contractor's to g ti. cop of approved piw APR 1 0 1998 �u AS NI{ EL RECEIVED CITY OF TUKWILA APR 0 11998 PERMIT CENTER Overhead I2" water teed Fire valve & alarm sensor External fire valve with chain lock and belt alarm on wall Roil Door H '18 -0104 _ J � - - - - -- r Rail Door NEIGHBOR WAREHOUSE ALSIDE SUPPLY CENTER 1105 ANDOVER PARK WEST BLDG. E TUKWILA WA 98188 ' H Shipping Doors NOTES: ALL SELECTIVE PALLET RACK MADE BY LMT FRAMES LM30 216 - -44 BPS -30 BEAMS LBF 453- 144 3 PIN "A" WELD LBF 454 -120 3 PIN "A" WELD LBF 404 -96 3 PIN "A" WELD FOOT PLATES 4 "X7 "X3/8" THICK WITH (2) HOLES NO SPECIAL INSPECTION REQUIRED` A. SHUT OFF VALVE FOR SPRINKLERS RISE IN FACILITY TO THE NORTH- ALLSIDE SUPPLY. B. THIS IS NOT AN ESFR SYSTEM. C. SPRINKLER RATED AT .39 GPM /MOST REMOTE 56 SQUARE FEET. Rail Door of CHARGER roe of t ANS SA F' WARE FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS CITY OF TL ;';!1A APPR!VEC APR 1 ; '. as V 0 3' -.S" SIDE 375 R IQ O O 0 C 0 RACK ELEVATIONS LM 30 8' -0" 10 - O "''OR 12 -0 FRONT .105 THK BRACKET ASSEMBLY 12 -0" TYP 1/8 ,:i00 THK IMMO LB1 45 015 TI-1K -� COLUMN STRUT 2 3/4' 7/8 /8 j ® 0 TYP BRACKET ASSEMBLY 8'-0" 075 THK TYP LBF 404 /2 -8 7'' 7/8" 5 1/4 2 3/4,,. r. 1/8 TYP 075 THK NOTES 1 RACKS ARE MANUFACTURED BY LODI METAL TECH (LMT) OF LODI, CA. 2 STEEL FOR ALL RACK COMPONENTS SHALL HAVE A. MINIMUM fy OF 50 k AND fu OF 65 ksi. 3. STEEL FOR ALL BASE PLATES CONFORMS 00 ASTM 036 WITH MINIMUM fy OF 36 ksi AND fu OF 58 ksi. 4. MAXIMUM RACK LOADS PER LEVEL PER PAIR OF BEAMS SHALL BE 4,000Ibs. 5. CONCRETE SLAB IS GIVIN AT 6" THICK WITH F'c =3000psi 6 ALLOWABLE SOIL BEARING IS GIVEN AS 2000psf FOR GRAVITY LOADS AND 2666psf OCR SEISMIC OR SEISMIC+ GRAV LOADS. 7. TIE DOWN ANC ITY HORS SHALL BE HILT! KWIK BOLTS OR E0010. USE 1/2 "0x4 1/21' ANCHORS WITH 3" EMBEDMENT. USE 2 ANCHORS PER BASE PLATL. SPECIAL INSPECTION !S NOT REQUIRED. 1/2 BRACKET ASSEMBLY 10' -0 TYP 1/8 LBF 454 1/2 -8 1 ,. TYP co i