HomeMy WebLinkAboutPermit D98-0117 - CONCURRENT COMPUTER - WALLSD98 -0117
375 Corporate Dr. S.
Concurrent Computer
City of Tukwila
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
DEVELOPMENT PERMIT
WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES,
APPLICANT IS PROCEEDING AT THEIR OWN RISK.
Parcel No: 262304 -9075
Address: 375 CORPORATE DR S
Suite No:
Location:
Category: AOFF
Type: DEVPERM
Zoning:
Const Type: V -N
Gas /Elec.:
Units: 001
Setbacks: North: .0 South: .0
Water: TUKWILA Sewer: TUKWILA
Wetlands: Slopes: N
Contractor License No: SGACO * *084BS
OCCUPANT CONCURRENT COMPUTER
.375 CORPORATE DR S, TUKWILA WA 98188
OWNER LOWE :NORTHWEST INVESTOR Phone: 2'0.6 575 -2120
600 UNIVERSITY ST #2820, WA 981.01
CONTACT DAVID KEHLE Phone: 206 - 433-8997
12720 GATEWAY DR S, SEATTLE WA 98168
CONTRACTOR SGA CORPORATION Phone,: 206'.778 -2191
6414 204TH STREET S.W. #200, LYNNWOOD, WA 98036
!**********•***********************************************• k•k * *** ***'k•X* * * * *•k *** * * *'k**
Permit Description:
REMOVE.EXISTING NON - BEARING WALLS, CONSTRUCT NEW
TENANT WALLS AND FINISHED. .
******• k***• k* k**** k******* k ********** * ** ** *•k** * * * •k *' * * *•k ** * * *•k **
Construction Valuation: $ 20,0.00.00
PUBLIC WORKS PERMITS: *(Water Meter Permits "Listed Separate) ,..,'Eng : "Appr:
Curb Cut /Access /Sidewalk /CSS: N
Fire Loop Hydrant: N
Flood Control Zone: N
Hauling: N Start Time:
Land Altering: N Cut:'
Landscape Irrigation: N
Moving Oversized Load: N Start Tinier_
Sanitary Side Sewer: N No:
Sewer Main. Extension: N Private:
Storm Drainage: N
Street Use: N
Water Main Extension: N '.Private:' N Public: N
k' k******* k * *'k *** * * *** * * *k'k ** * *** ** * * ** * ** ** **•k* ** * *** Ec *** * *•k* *•k * **** ** *•k* ** * * * *•k*
TOTAL DEVELOPMENT PERMIT FEES: $ 478.46
k.******• k*** * ** * * * *•k * * * ** * * *•k *•k *k ** * * * ** 1c********** � k• A *'*'k *•k * * ** * *•k * * * ** * *** * * * *** *SIC **
Permit Center Authorized Signature:':
Print Name:_
Permit No:
Status:
Issued:
Expires:
(206) 431 -3670
D98 -0117
ISSUED
05/20/1998
11/16/1998
Occupancy: OFFICE
UBC: 1994
Fire Protection: SPRINKLERED
East: .0 West: .0
Size(in): .00
End Time:
Fi11:
jL E Date: -- 40 - '/O
I hereby certify that I have read and examined this permit and know the same
to be true and correct. All provisions of law and ordinances governing this
work will be complied with, whether specified herein or not„
The granting of this permit does not presume to give authority to violate or
cancel the provision of any other state or local laws regulating construction
or the performance of work. I am authorized to sign for and obtain this
developme rmit. �1
'e
S i g n a t u �vZ.l�ilt.l�..� ks�%t -�? Date: � Q
This permit shall become null and void if the work not commenced within
180 days from the date of issuance, or if the work is suspended or abandoned
for a period of 180 days from the last inspection.
Address: 375 CORPORATE DR S
Suite:
Tenant:
Type: DEVPERM
Parcel #: 262304-9075
ockA*********A***********************************-****************4,*******A**
Permit Conditions:
1 . No changes w i l l he made to the plans unless approved by the
Architect or Engineer and the TukwAla Building Division.
2. Electrical permits shall be , .,oi?44ned . ri . ..:0ir.pqgh the Washington
State Division of Labor and Indus tr i et"? electrical
work wi 11 be insp by that agency
3. Al 1 mechanical':-;*01* shall be Unde i. l permit, issued: by
the City f;,'1Uji i
4. All peroftt:S, inspection - records„ and approVed.. ansshall be
available the Sob site prior to itie:-,start!'''ofj any
s Groot 100. „Tiles'e 'are9 he maintained and
able until final inspection approval is granted.
5. All construction to be done in conformance with approved Plans7and/requirements".,:cithe Uniform Building Code.
Edition) m en , Uni form '::'Mq6an ca Code (1994
and;)Washingtonc State ::Energy . ;Code " E d i t i o n ) .
6. Validity Permit. The issuance of a permit or appro of
plans, specifications, en,d IcOmput*tiOnS I not. be con
str:yed to be a Perwit fbr,;Or, an. approval of any v
of any of the provisions Of the hul iding Ode or of ?,anY.:,
other ordinance-,of juri'Sdi ction. ;- — No...perm t presuming .to:.
give author y to violate or cancel, the provisions of this
code slilIT' be yell*.
`;:' ,;-4 ■
7. VENTILATION IS REdUIREDFOR ALL%NEW . SPACES OF K
OR EXISTING BUILDINGS IN CONFORMANcE WITH THE UNIFORM,,,
BUILDING CODE AND THE WASHINGTON STATE VENTILATION ..ANOPJ.,:
INDOOR AIR - 'AQUALITY CODE, CHAPTER 51-1.3 1 ,4Ac..''' ., :,
,
.t
CITY OF TUKWILA
Permit No: D98-0117
Status: ISSUED
Applied: 04/07/1998
Issued: 05/20/1998
Project Name/Tenr
� `
Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital
❑ Church ❑ Manufacturing ❑ Motel /HotelOffice
❑ School /College /University El Other
Value of Constructs# to
t
7/9 ae izet x.e2. Site Address:
City State /Zi
-it
T Par
I Numb
Property Own
,
L
os
Phone:
VWC- 1 „C0
Street Addre� l iftwit . �, � .�� M h C it � � b te /dip
'' // t �• w uU G�
Fax #:
y_Z�B�'3
%w
Contractor:
Phone:
Street Address:
City State /Zip:
Fax #:
Architect: � v`l2
t r' ,/ ` _
Phone:
Str1ii i((JJ resse � I' IIlo
o
#:
Phone:
/44?-8&01
Engineer:
Street Address:
City State /Zip:
Fax #:
Contact Person: 291,0 6
Phone:
423 •eSnli
Street Addre �.E'rttyV `v%/
Fax #:
14' C "�" 1
5mici6. 1 WD S96/�ItlS
Description of work to be done: F J K. I.- r-I ki Ow, abgenitcr 14H4 IENbat
J*LLS 5u0 1II.1 IIIv
Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital
❑ Church ❑ Manufacturing ❑ Motel /HotelOffice
❑ School /College /University El Other
Proposed use: CI Retail CI Restaurant CI Multi-family ❑Warehouse ❑Hospital
CI Church ❑ Manufacturing El Motel /Hotel Office
El School /College /University ❑ Other
Will there be a change of use? ❑ yes Mno
If yes, extent of change: (Attach additional sheet if necessary)
Will there be rack storage? ❑ yes no
7( Existing fire protection features: sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify)
Building Square Feet: 1110002i existing
Area of Construction: (sq. ft.) 'UAW
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no
Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets
CITY OF TUf 'VILA
Permit Center
6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188
(206) 431 -3670
Commercial / Multi - Family Tenant Improvement / Alteration Permit Application
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
APPLICANT REQUEST FOR PUBLIC WORKS"SITE/CIVIL PLAN REVIEW 'OF THE "FOLLOWING :. :,
(Additional reviews may be determined by the Public Works Department) '
Curb cut/Access /Sidewalk ❑ Flood Control Zone
Size(s):
cubic yds. 0 Fill cubic yds.
❑ Sewer Main Extension
❑ Water Main Extension
0 Deduct
❑ Channelization /Striping ❑
❑ Fire Loop /Hydrant (main to vault) #:
❑ Land Altering 0 Cut
❑ Sanitary Side Sewer #:
❑ Storm Drainage ❑ Street Use
❑ Water Meter /Exempt #: Size(s):
❑ Water Meter /Permanent it Size(s):
El Water Meter Temp # Size(s): Est. quantity:
❑ Hauling
❑ Landscape Irrigation
O Private 0 Public
O Private 0 Public
0 Water Only
gal Schedule:
❑ Miscellaneous
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and
is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by
the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
Date application:
Date application expires:
fib 1
Applic#Iop taken by: (initials)
PLEASE SIGN BACK OF APPLICATION FORM
C.TPERMiT.DOC 1/29/97
"'ts w tt co
tf w`Z 40.
BUILDING • l • THORIZED AGENT:
Signature: a , w ,
Date:41 1 f(p y
3 t41 m E
Print name: �
t!
o c' A
Phone:
,
w�v
/�
FaX , .8 %1
-tom
Address
�
61 t12,
�
Urfr like
/State /Z
Cit y ai
t.O• altar
ALL COMMERCIAUMULTI -FAY TENANT IMPROVEMENT /ALTTTION PERMIT APPLICATIONS
MU E SUBMITTED WITH THE FOLL ING:
ALL DRAWI��$,TOlpE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT,
STRUCTUI'AL ENGINEER OR CIVIL ENGINEER
i> ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ Sr Complete Legal Description
U y- ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Four (4) sets of working drawings (five(5) sets for structural work), which include :
❑ Site Plan (including existing fire hydrant location(s) I,(l4rt4 f )
1. North arrow and scale
2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas
5. Recycle collection location and area calculations (change of use only)
6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of
use only)
9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of
those, identify by size and species which are to be removed and saved
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change
of use only)
11. Location and gross floor area of existing structure with dimensions and setback
12. Lowest finished floor elevation (if in flood control zone)
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H-
,-y 9).
U Floor
D C.�
Pr
❑ ❑
plan:
show
location of tenant space with
proposed
use of each room
labeled
Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of
any hazardous materials; dimensions of proposed tenant space.
Vicinity Map showing location of site
Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of
rack. Structural calculations are required for rack storage eight feet and over.
Indicate proposed construction of tenant space or addition and walls being demolished
Construction details
Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of
water supply to sprinkler vault with documentation from contractor stating supply line will meet or
exceed sprinkler system design criteria as identified by the Fire Department.
Washington State Non - Residential Energy Code Data shall be noted on the construction drawings.
SEPA Checklist - if intensification of use (check with Planning Department for thresholds).
Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
land use or SEPA decisions.
Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of
Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5)
Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no
contractor has been selected at time of application a copy of this license will be required before the
permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal
I HEREBY CERTIFY THAT ! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND ! AM AUTHORIZED TO APPLY FOR THIS PERMIT.
CTPI.1'tMIT,000 1 /29/97
Account Code
000/322.100
'000 /386.904
i'::f+ 'i- tv , Y'� . 5•T(.�; ^ `� r . Nf i rvl 7A1 v. k''".JAj z1�5�41tif� .aS:���f�n�"G�.r� {M`V1+ : }� a•.'1'+ ^`t�1Fa- {t. {'{1..iY� lv'4�'1•iriF�lp{;1�E
X'r t- `•'�•ry a't*itBv ayf. i' �t4 "7!r.i�i:�1�,��
0
Description
BUILDING — MOINES'
STATE ULIILDIhC"' SSURCHAR,OE
•
•kA••k:k**** *A'kA••. * A•*** I- 'kA * * ***A:1+:.at9c::•k•k•k1C* t •IchAitfc•k• #:4:k;l*• *kicA kA k•A•kk*
CITY OF TUKWILA, WA TRANSMIT
*•*** * * * * *** * ** * **k:k• ****: kA#k• k** **•k ** *k **" *k *k•,1 * *•k * *:1 k** **•k * *•k
TRANSMIT Number: 89700768 Amount: 291..7 5 05/20/98 14:58
Payment Meth +d: CHECK flotation: DAVID .1 EHLE ARCH Ini t: 13_H
Permit No 098- -011 Type: DEVPERM DEVELOPMENT PERMIT
Parcel. No: 262304 —=075.
Site Address: 2 ?5 CORPORATE DR S
:Total Fees: 4783.46
This Payment 291.75 Total ALL Pmts: =..{ . 478.46
Balance: .00
•,4** *A * * * *o4 * + *sl *^4* **** a•*** A*• A ** *k * *A*A* *41** * * * * *4 * *,h*' #***
Amount
287.25
2276 05/22 9717 TOTAL .483.50 '
'
^�^
+A*aA**0+x++A**A*++
CITY OF TUKNlLA, NA ` TRANSMIT
*++++^+a++a++/+
TRANSMIT Number: 897OO74t Amount: 186,71 04/07/98 15:59
Payment Method: CHECK Notation: DAVID AEHLE ARCH Init: BLH
Permit No: D98-0117 Type: D[VPERM DEVELOPMENT PERMIT '
Parcel No 2623O4-9O75
Site Address: 375 CORPORATE DR S
Total Fees: � : 478.46
This Payment 186.71 Total ALL Pmts: 186.71
Balance: 291.75
*+/**+x+++*+*+***+++a*+«****^+a+a+++a+*+**+**++**aA.^***A^*+a«*+*
Account Code Description Amount
000/345.830 PLAN CHECK - MIRES , 186.71
| � 0841 04/08 1717' TOTAL oro"ry
Wt Pro h l f er ++
� t%i I
Ty , y
Date call r .l�•t
: Ogg
Date wan 39 ..C/ Q' .m
A
5 Corp Pr5
Special instructions:
Requester: 01 1' H r :'i
Phone tC
5 �w...05 V
kl"" 17 "r!ti:�^.'rtr*r�.+,N';,�.Y. ^ "r; .:'±."�' 'r']';ti3�,�KrFC: =:'1 : ,.- "'.ai.' r,'ri r•h�w • v$�a
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 988 - � (206) 431 - 3670 .
Approved per applicable codes.
COMMENTS: f ---'
Date:
( 3-0 )%a
C I $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Inspector:
INSPECTION : RECORD('
Retain a copy with perm
(A ► 1 ,
PERMIT NO'"
Corrections required prior to approval.
Receipt No.:
Date:
Project: et , Laveh
„ � f
yl ��
� e
of inspection: � . I '
�-
Address:
Y
X C .n (1Ut2r
�v s
Date ca lled:
—
(,
Special instructions: '
Date wanted:
zei
a
Requester:
-
Phone No.:
4 5- - f
4 - o5l0
INSPECTION RECORD,r.
Retain a copy with permL,
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila, WA 98181
Approved per applicable codes.
COMMENTS:
Inspector:
3:15 P n\ ms t.-
■
Date:
p1e -
PERMIT NO.
(206) 431 -3670
Corrections required prior to approval.
Date:
1 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection,
Receipt No.:
Pr ec7 r.00-10 4-- (O �
Type of inspection: ! l
c- � / �'
Address:
Date called:
Special instruc tons
Date wanted: 6......5-7,,9 5 y am
' �:'
Requester:
Phone No.:
INSPECTION RECORDn
Retain a copy with perml,�
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
RMIT NO.
(206) 431 -3670
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
1 $42.'O— REINSPECTIO► FEE ROUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection.
Receipt No.:
Date:
Project: ,
� rv ('r. ',PPfr ' 1 Pony2
Type of inspection:
/- "ti /
Ad ress:
3 r
be s
Date called:
(r 4
Special instructions.
Date wanted: /
a.m
C ^ "/
p.m.
Requester:
Phone N°/?S' - S( -C •
»3
�Fnrx�;;� .c'R"^�+gr��ri+s++navw Sao. k•. ray0.' SrSpL"; Wr: r �rr 'h�
INSPECTION RECORD
Retain a copy with perm
':
INSPECT! N NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
Inspector:
I
.„A , (4,0k)
J 0 ■
Date : /'
PERMIT NO.
(206) 431 -3670
COMMENTS:
1
Corrections required prior to approval.
I $42.00 FEE REQUIRED. Prior to Inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
nr
City of Tukwila
Fire Department
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name CO YI CV (' C C VN* L yyl,P v *cC"'
Address 31 5 Co Cr (c� n c- Suite # a()()
Retain current inspection schedule
5Z Needs shift inspection AV v
. Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
Authorized Signature
FINALAPP.FRM
T.F.D. Form F.P. 85
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Permit No. S
Date
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fay (206) 575-4439
DEPARTMENT:
B i di1 D'vision '
Public Works
RA L t 44c C
TUES /THURS ROUTING:
Routed by Staff
\PR•ROUTE.DOC
1/98
•
PLAN R�W /R OU�T�ING L
f
Fire ention
/kw - 4 -ft 1t
Structural
DETERMINATION OF COMPLETENESS: (Tues, Thurs)
Complete Incomplete n
Please Route ❑
REVIEWERS INITIALS:
APPROVALS OR CORRECTIONS: (ten days)
Approved ❑ Approved with Conditions El
REVIEWERS INITIALS:
CORRECTION DETERMINATION:
Approved ❑ Approved with Conditions El
ACTIVITY NUMBER: D98 -0117 DATE: 4 -7 -98
PROJECT NAME: CONCURRENT COMPUTER
(if routed by staff, make copy to master file and enter into Sierra)
Plan i� Division
3 ❑
Perm Coordinator
DUE DATE: 4 -9 -98
Not Applicable
Comments:
No further Review Required
DUE DATE: 4 -23 -98
DATE:
Not Approved (attach comments) ❑
DATE:
DUE DATE.
Not Approved (attach comments) ❑
REVIEWERS INITIALS: DATE:
Dear Sir:
City of Tukwila
Fire Department
Fire Department Review
Control #D98-0117
(512)
April 17, 1998
Re: Concurrent Computer - 375 Corporate Drive South
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. Maintain fire extinguisher coverage throughout.
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher ", with an arrow pointing to the unit.
(NFPA 10, 1 -6.3) (UFC Standard 10 -1)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1 -6.5)
2. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 1207.3)
Obstructions, including storage, shall not be placed
in the required width of an exit, except projections
as permitted by the Building Code. Exits shall not be
obstructed in any manner and shall remain free of any
material or matter where its presence would obstruct
or render the exit hazardous. (UFC 1203)
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575449
f
1.
City of Tukwila
Fire Department
Page number 2
space.
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 1207.1- 1212.8)
Aisles leading to required exits shall be provided
from all portions of buildings. Aisles located within
an accessible route of travel shall also comply with
the Building Code requirements for accessibility.
(UFC 1204.1)
Exits shall not pass through kitchens, storerooms,
restrooms, closets or spaces used for similar
purposes. (UBC 1003.5)
Exit doors shall be maintained in accordance with
Section 1207. Exit doors shall be maintained in an
operable condition. Doors installed as part of
required fire assemblies shall be maintained in
accordance with Section 1112. (UFC 1207.1)
3. Maintain sprinkler coverage per N.F.P.A. 13.
Addition /relocation of walls, closets or partitions may
require relocating and /or adding sprinkler heads.
All new sprinkler systems and all modifications to
existing sprinkler systems shall have fire department
review and approval of drawings prior to installation
or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than
50 heads shall have the written approval of the
W.S.R.B., Factory Mutual, Industrial Risk Insurers,
Kemper or any other representative designated and /or
recognized by The City of Tukwila, prior to submittal
to the Tukwila Fire Prevention Bureau. No sprinkler
work shall commence without approved drawings. (City
Ordinance #1742)
Contact The Tukwila Fire Prevention Bureau to witness
all required inspections and tests. (UFC 10.503)
(City Ordinance #1742)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439
City of Tukwila John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fin? Chief
Page number 3
4. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
5. Required fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
requirements based on type of construction, draft stop
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall be
properly repaired, restored or replaced when damaged,
altered, breached, penetrated, removed or improperly
installed. (UFC 701)
This review limited to speculative tenant space only -
special fire permits may be necessary depending on
detailed description of intended use.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439
f62i.QS,1.O (6'S71
1
DEPARTMENT OF LABOR AND INDUSTRIES
REGISTERED AS PROVIDED BY LAW 'AS
CONST CONT GENERAL
_ RECISTRA.TION.NTJMri1 R<
!CC01 ` SGACO ** 084BS ,011.10
k'FECTIV .DATE ::; _ 0x./1:0/1992::
S G.A CORPORATION
6414 204TH ST SW 200
'LYNNWOOD WA 98036-5973
Fb15.11S:.
REGISTERED A5 PROV"JEO•DY LAW AS k
t .iCLY.itT.. .1 "1T.2"::.....,n. .
Dztcch And Displuy Certificate
REGISTERED AS PROVIDED BY LAW AS
I CONST CONT GENERAL
REGISTRATION NUMBER Please Remove
CCO1 SGACO * *084BS 01/10/1999 And Sign
EFFECTIVE DATE • 01/10/1992 Identification
S G A CORPORATION Card Before
6414 204TH ST SW 200 Placing In
LYNNWO� WA 98036 - 5973.. billfold
) �
Signo.f4e % /� " � 't � /1
Issu(dyy'DEPARTNIENT OF LABOR AND INDUSTR ,S
L�
ED SECOND FLOOR KEY PLAN
SEPARATE PERMIT
Rc (ABED FOR.
K / MECHANIC AL
J g � ELECTRICA
PLUMBIN
GAS PIPING
D P 1("UJ
,LDING DIVISION
FILE COPY
) 4nderstend that the Plan Check approvals are
1 subject to errors and omissions and approval of
plans does not autho z h violation of anY
adopted Node or ordinance ,p ; t of con -
nOtor AygPY of approved plan acknowledged.
Gate v V1' 1
Parma No
h GILL MZ
1 $O REC. NO. 5973722
LEGAL DESCRIPTION
THAT PORTION IF THE EAST HALF OF THE 1MY2THYEST,QU TER ff TIE
SOUTHEAST QUARTER EF SECTION 26, tO04SH 23 NORTH,. RA NGE '4
Y.M., IN KING COENTY, WASHINGTON Rile') AS FILMS" ':
BEGINNING AT THE NORRIEAST CORtCR or SAID EAST HALF WDi1CH .OS
NORTH 88005 "42' WEST AEOMG Tie WITH LINE IF SAID 5WTHET
QUARTER A DISTANCE OF 1,339.34 FEET FRIi4 TAL NORTHEAST HER OF
SAID SOUTHEAST QUARTER; THENCE SOUTH 01047'29 WEST:A40141'THE;
EAST LIFE IF SAID EAST'MtLF A DISTANCE If 1;32234 FE9T 1.0-
SOUTHEAST CORNER TFETEg DISTANCE OF 659.35 FEET TAI-THE
LINE IF THE EAST 659.34 FEET OF SAID EAST HALF- T` €14 N
01047'29' EAST ALONG SAID WEST LINE A DISTANCE IF 1,320;
TO THE NORTH Litt TI SAID EAST AAI.Fi THENCE SIIJTH 86605'
ALONG SAID NORTH Lite A DISTANCE OF 659.34 FEET TO Tie All
BEGIFOJING;
EXCEPT THE EAST 30 FEET THEREOF FOR ROHDH
ALSO EXCEPT RAILROAD TRACKAGE AS RESERAED BY UNION PACIFIC
RAILROAD COMPANY AS DISCLOSED BY DEt-D RECOftIED UNDER RECORDING
Na. 7607070502;
ALSO EXCEPT THAT PORTION OF SAID SUBDIVISION DESCRIBED AS
FO.LOWS
BEGINNING AT A POINT IN Tie WESTERLY MARGIN'OF. -PAR$ ,WEST,
WHICH POINT BEARS NORTH 88005•45' WEST 1,36934 FEET AL I1(G TIE
NORTHERLY LINE OF SAID SOUTHEAST QUARTER, AND 098111 L 0IA
WEST 451.30 FEET ALOG 'SAID WESTERLY HARGINID' A 6 ,
FROM THE N[RT1EAST CORNER OF SAID SOUREAST 'UTARTEIE/.
SAID POINT IF BEGINNING LEAVING SAID WESTERLY MARGIN, TMIG6N
THE PRECEDING COURSE, ALONG; THE ARC OF A CURVE-TO THE RIGHT
HAVING A RADIUS OF 50,000 FEET AND A CENTRAL ANGLE tTF- 9U0064-9 ' ,
AN ARC LENGTH OF 78.64 FEET TO A POINT III A LINE THNAT'IS P.ARAE,At
TO AND 501.40 FEET SOUTHERLY 1F THE tNOTIRRLY LII€ IF SAID"
SOUTHEAST QUARTER; THENCE ALONG SAID PARALLEL LINE NORTH'
90o15'42' WEST 326.76 FEET; THENCE LEAVING LAST SAID PARALLEL
LINE TANGENT TO THE PRECEDING COURSE ALONG RTE ARC ..IF A EYi1t1lE TO',:.
TIE RIGHT HAVING A RADIUS OF 15.00 FEET AND A CENTRAL
54o45'56', AN ARC DISTANCE OF 14.34 FEET TO A POINT ;IF :.REVEF
CIEVATIDEi THENCE TANGENT TO THE, PRECEDING CURVE A11>NCi:,
A CURVE TO THE LEFT, 099111 A RADIUS OF 50.00 FEET AND•
ANGLE OF 289031'52' AN ARC DISTANCE OF 252.66 FEET TO� A
REVERSE CURVATURE; THENCE TANGENT- TO THE PRE CURVE
THE ARC OF A GAVE TO THE RIGHT, HAVING A RADIOS I 15:
AND A CENTRAL ANGLE OF 54045'56', AN ARC LENGTH Df Tp.34
A LINE THAT IS PARALLEL TO AND 546.40 FEET JTAt61LY, ;EJ�',
NORTHERLY LINE IF SAID'SOUTIEAST QUARTER) THEN
PARALLEL LINE SCUM 88005'42' EAST 327 -.-05 FEET
SAID PARALLEL LINE, TANItNT TO -SAlE- PRECEDING CT
ARC OF A CURSE TO THE RIGHT, HAVING A RADIUS OF 5D O9 Al
CENTRAL ANGLE OF 89053'11'. AN -ARC LENGTH IF 78,44.ITET
POINT ON THE WESTERLY MARGIN .IF ANDOVER PAC IEm 98
SAID WESTERLY MARGIN NORTH 01047'29' EAST ^ 145 00 FEET
POINT OF BEGINNING;
ALSO EXCEPT' THAT PORTION NONE PARTICIB,ARLY IESERII D AS FIB:
BEGINNING AT A POINT RBI THE WESTERLY MARGIN. OF AND R.PARK.WEST
WHICH POINT BEARS NORTH'' 88005'42' WEST 1,369.34 FE£T THE
NOTHERL7 LINE OF SAID SOUTHEAST QUARTER NO SIRITH 0104729
973.30 FEET AIRING SAID WESTERLY MARGIN or - JiDOVER P
THE NORTHEAST CORNER IF SAID SOUTHEAST QUARTERR,
THENCE FROM SAID POINT OF BEGINNING LENT* SAID WEST
TANGENT TO THE PRECEDING COURSE, ALONG TIE: ARC4 5 f A
RIGHT HAVING A RADIUS OF 50.00 FEET AND AC
90o06'49', AN ARC LENGTH OF 78.64 FEET TO A PII
IS PARALLEL TO AND 1023 40 FEET .SOUTHERLY IF S#E FR1
OF SAID SOUTHWEST QUARTER)
THENCE ALOICT SAID PARALLEL LINE NORTH 8BA05:42' Y
THENCE LEAVING LAST SAID PARALLEL - LINE TA14ENT'TO TI$. FIZEt
COURSE A 980 THE ARC IF A CURVE TAX THE RIGHT<HAVING ROD
15.00 FEET AND A CENTRAL ANGLE IMF >54045'S6',. ARC DI
14.34 FEET TO A POINT OF REVERSE CIRYATUREI
THENCE TANGENT TO THE PRECEDING CURVE ALOG TIE ARP I
THE LEFT Mi A RADIUS OF 50.00 FEET AND A'; CENTRAL
289031'52', AN ARC DISTANCE OF 252.66 FEET TO A PO
CURVATURE-
THENCE TANGENT TO TIE PRECEDING CURVE ALONG THE ARC IF A €9
THE RIGHT HAVING A RADIUS OF 15.00 FEET AND A C E NTRAL AN
54045'56', AN ARC -LATH O' 14.34 FEET TL
TO AND 1,068.40 FEET SOUTIEREY It THE LERTIERLY L
SOUTHEAST QUARTER- THENCE AL@G SAID PARALLEL U A
88005'42' EAST 327.5 FEET- THENCE LEAVING SAID P Ar
TANGENT TO THE PRECEDING COARSE, ALONG Of .SRC IF:A
RIGHT HAVING :A RADIUS OF 50.00 FEET AND A CENTRAL^ " AN
89o53'II', AN ARC LENGTH If 78.44 FEET TO -POINT O4
MARGIN IF ANDOVER PARK' WEST; THENCE ALONG SAID IES
NORTH 01047'29' EAST 145.00 FEET TO THE POINT OF REGINMI
GENERAL:
LAND USE C.M. INDUSTRIAL
CODE 1994 U.B.C. W/ AMEN
SEISMIC ZONE 3
FIRE ZONE III
OCCUPANCY B OFFICE
CONSTRUCTION TYPE. VN SPRINKLERED
PARKING.
STANDARD 110 STALLS
COMPACT = 2
HANDICAPPED = 2
TOTAL PARKING 114
PARKING RATIO 1/150 SF
BUILDING ADDRESS 685 ANDOVER W.
TAX PARCEL NUMBER: 262304- 9075 -00 (FOR E
TENANT AREA = 2,016 S.F.
R _j
7 - ATALT.
P130511' STATIC CARPET II/RUBBER BASE
VALL GYP. DD. PAINTED
CEIllNG EX. SUSPENDED ACOUSTIC - PATCH AND REPAIR
REPLACE TILES AS REQUIRED
F,LtDIR ANTISTATIC VCT -OIR SHEET VINYL W /RUBBER BASE
WAX, GYP. BD. PAINTED
CEILINDU EX,; SUSPENDER ACOUSTIC - PATCH I. REPAIR
REPLACE TILE AS REQUIRED
98T€ ' H SEPARATE A TERNAff PRICE TO USE
#9 -TYPICAL 30 CARPET
B),. . TYPICAL ` VET (ARMSTRNG. EXCELGN 1/8')
.SCHEDULE
D1.9J�C SC0EDOLE (MaN BURRS TOS HAVE LEVER HANDLES, MATCH EXISTING
FINISH AND STYLE REUSE EXISTING DOORS AND FRAMES)
1
EEXISTING GDIS 3' - 0' X 7' - S.C. 01110, 20 MIN. RATED, RE-KEY
2 EXISTING 3' -0' X 7' -D` S.C. WOOD, 20 MIN. RATED, FIX IN
PLACE, REMOVE INTERIOR HARDWARE, SIGN HALL SIRE 'THIS DOOR
IS LOCKED' TO MATCH BUILDING STANDARD SUITE NUMBERS.
3 - 6,8 NEW OR -RE -USED: 3' -0' X 7' -0' S.C. WOOD WITH METAL JAMBS,
LAICHSETS, SILENCERS, WALLS STOP.
7
NEW ' #R- R-USED ;3' -0' X 7' -0' S.C. 01030 WITH METAL JAMB,
LITCKSET, SILENCER, WALL STOP, THRESHOLD.
9 10 [OPENINGS, 3' -0' X 7' -(1' GYP. BD. RETURNED.
,kiNffW . SCHEDULE
1) EXISTING BUILDING ENVELOPE IS NOT BEING MODIFIED, 1-VAC
Z011J#AAi AND THUNOSTAT LIEATIONS TO BE REVIEWED AND
APPROVED BY. TENANT' AND'! OWNER.
12J LIGHTING IS BEING RE -USED (AT LEAST 65X); AND IS
TIEREPEDE EXEMPT FRAM ENERGY CODE REQUIREMENTS.
3) TENANT REQUESTS ALL OFFICES (4 -7) BE MULTI- LEVELED
SWITCHED (2 OUTBOARD, 3 CENTER, 3 ON, 3 OFF).
;4} LIItAHTCIRCUITINT SHALL NOT EXCEED 90' /. OF A -20 NIP
v v CIRCUIT.
F, WORK.
RENWEIDE €XISTING MO- DEARIIO WALLS. CARPET AND BASE, INSTALL
Mid REWIRIN ANT
TEN" WALLS, BmRS, FINISHES,' ETC.
LE END
EXISTING BALL
NEY STEEL STUD WALL TO UNDERSIDE OF CEILING
1 $Z82 NEV STEEL STUD WALL WITH SOUND INSULATION FORM TYPE /
CAULK AT'BASE, 2' -0' ES, AT CEILING WITH SOUND BATTS.
_ - - EXISTING'WALL TO BE REMOVED.
NEY DOR
EXISTING 000W
F : EXISTING DOER TO BEREMEIVED
EXISTING CARPET 6 BASE)
2' -0' ii 6' -6' (SILL AT +6' A.F.F.) FLOW METAL FRAMES
C PAINTED) W /TEMPERED SAFETY GLAZING (CLEAR)
F13112-PLEX ISOLATED GRORIG 20 A, ORANGE, 2 CIRCUITS
DUPLEX rOLFILET
WALL TELEPIEDE AND DATA OUTLET, MUIRING, CONDUIT AND PULL STRING
ONL9,
THERMOSTAT
ILLUMINATED EXIT SIGN
2' X 4' EXISTING LIGHTS TO REMAIN
(NO CHANGES, SWITCHING PER PLAN)
RECESSED CANS TO IE REMOVED. REPLACE CEILING TILES
F OR A / 208 V
4R
IRE PARCEL
r.
FLOOR PLAN
10' 15
25'
®®
SCALE I/8" = I' -0"
REPLACE. TILES AND
59405 40 ItQiItP
mmommigniwrovamme
■ ®■■1%/run ■■■■
® ■■ ®% ®■1 ■®
• ■o,- o'am
■
®\E
I -m' EXISTING WALL
TiROUGHGAND
A
AMINI711.1
MINIA111111111111
®®
■■
L
CORING TILES 2' x 4' S LOOK TEGItOR EDGE
REFLECTED CEILING PLAN
SCALE 15
25'
35
0' I'
2'
COUNTER
SCALE 1/2" = I
PLASTIC LAMINATED FACED
FLIER OVERLAY CABINETS
W/AD.AMTADLE SHELVES
PLASTIC LAMINATE
&4QCSPLASH
AND COINER TOP
PLASTIC LAMINATED EDGE
PLASTIC LAMINATED FACED
FILEN 0998.4Y CASHES
TYPICAL INTERIOR FNIB0 KORTRON
OR PLASTIC LAMINATE
9'
PALLS 926 D)
b'Pi-01 (1
CM PPR°E°
R 2 3 1998
DING omsl oN
9Ul
APR 07/998
P CE
:TER
N C4
63
a<
TA -1